# Asset discovery Source: https://docs.kodelabs.com/products/assetops/assets/asset-discovery Define data sources, run discovery, configure field mapping and matching, and link assets at the building level **Asset discovery** lets you import and onboard assets at the [building level](/products/assetops/quickstart/usage-workflow#building-level). You define a data source from an Excel template, then run discovery to add assets to the building. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR subgraph s1["Data source"] B2["Asset 1"] B3["Asset 2"] B4["Asset 3"] end subgraph s2["Define data source"] B1["data-source.xlsx"] D["Data sources"] Z["Data source name"] end B1 -- define assets --- B2 & B3 & B4 AD["Asset discovery"] -- access --- D & DL["Discovery logs"] D -- upload --- B1 DL -- initiate --- ID["Initiate discovery"] ID -- discover --- s1 D -- define --- Z B2:::Rose B3:::Rose B4:::Rose B1:::Sky Z:::Sky ID:::Sky classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C linkStyle 0 stroke:#FF6D00,fill:none linkStyle 1 stroke:#FF6D00,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#00C853,fill:none linkStyle 6 stroke:#00C853,fill:none linkStyle 7 stroke:#FF6D00,fill:none linkStyle 8 stroke:#00C853,fill:none ``` Open a building from [Buildings](/products/assetops/resources/buildings), then select **Asset discovery** in the building sidebar. Use the secondary navigation: * **Data sources** — Upload and manage import files * **Discovery logs** — Run discovery and review results * **Configurations** — [Field mapping](#field-mapping) and [matching rules](#matching-rules) * **Asset linking** — Merge duplicate assets into one record *** ## Concepts and rationale **Asset linking** associates newly discovered assets from data sources with existing assets in your building. When multiple discovery sources (BMS, CMMS, IoT sensors) detect the same physical device, linking keeps one record so the database stays accurate and free of redundant entries. Asset linking provides these capabilities: | Capability | Description | | - | - | | **Duplicate check** | Runs automatically after discovery, and on demand when you choose match fields. Profiling recommends the strongest fields for the site | | **Scored suggestions** | Each candidate pair includes a match score so you can filter and confirm high-confidence links first | | **Linking confirmation** | You review suggested links, confirm matches, and merge information without creating a duplicate | | **Manual linking** | Pair assets yourself when suggestions do not fit | Configure [field mapping](#field-mapping) and [matching](#matching-rules) before you link assets. Merged asset fields follow mapping priorities. Duplicate checks use profiling-driven fields and the match configuration you accept or adjust. ### Linking constraints > [!WARNING] > > An asset cannot link to another asset that originates from the same external source. This rule prevents circular references and keeps data logic consistent in your asset database. *** ## Data sources ### View data sources ![Asset Discovery Data Sources table with Name, Connector Type, and Last Discovery columns plus Add Data Source button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-discovery-data-sources.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=221c013458bf9781dccd617a2f400b08) The Data sources page lists each source with connector type and last discovery time | Column | Description | | - | - | | **Name** | Data source display name | | **Connector type** | How assets are retrieved (for example, KODE API for uploaded templates) | | **Last discovery** | Date and time of the most recent discovery run | Use **Search** and **Filters** to find sources. Select **+ Add data source** to upload a new file. Open a data source's row menu and select **Download import sheet** to download the file used for that source. You can review the existing import or use it as the starting point for your next upload. ### Add a data source ![Add Data Source modal with Name field, template download steps, and file upload area](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-discovery-add-data-source.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=cdc8229f9e738f140626de9085ed908a) Download the template, fill asset data, and upload the completed file **1. Open Data sources** Navigate to **Asset discovery** > **Data sources**. **2. Select + Add data source** Select **+ Add data source**. **3. Download and complete the template** 1. Download the [asset import template](/downloads/asset_import_template.xlsx). 2. Fill in asset data using the template columns. 3. Upload the completed `.xlsx` file in the **File** field. **4. Save** Enter a **Name** for the data source and select **Save**. > [!NOTE] > > Uploaded sources use the provided template format. To connect other connector types, configure integrations in [Cloud BMS](/products/kode-os/get-started/introduction). **Template column reference** | Field | Example | | - | - | | ID | `AHU-RT-01` | | Name | `Rooftop AHU - Zone A` | | Category | `HVAC` | | IP address | `192.168.10.45` | | MAC address | `00:1A:2B:3C:4D:5E` | | Model number | `48HC-24-500` | | Serial number | `SN-2024-88421` | | Status | `Active` | | Location | `Roof - Zone A` | See the template file for the full column list and required formats. ### Discover assets from a data source Open the row menu on a data source and select **Discover assets** to start discovery without opening **Discovery logs** first. You can also download the source's existing import sheet from this menu. ![Data source row menu with Discover Assets, Edit, and Delete options](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-discovery-discover-assets-menu.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=22d9e40e18ad1e1ad81db80b30195c2c) Use the row menu to discover assets, edit, or delete a data source *** ## Discovery logs ### View discovery logs ![Discovery Logs table with Data Source, Date and Time, Discovered and Cancelled status badges, User, Discovered count, and row actions](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-logs.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=b5e6fe35adcbdffa76d4aac9cb583f4d) Discovery logs list each run with status badges and actions to open results | Column | Description | | - | - | | **Data source** | Source name and connector type (for example, **KODE API**) | | **Date & time** | When discovery started | | **Status** | **Discovered** when complete, **Cancelled** if stopped, or in progress while running | | **User** | User who initiated the run | | **Discovered** | Count of assets found in the run | Row actions: * Select the arrow icon to open **Results: Asset Discovery** for that run * Select the **X** icon to cancel or remove the log entry when available Use **Search** and **Filters** to find runs. Select **Initiate discovery** to start a new run. ### Initiate discovery Select **Initiate discovery** to open the discovery dialog. ![Initiate Discovery modal with Choose Data Source dropdown and Initiate Discovery button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-discovery-initiate-discovery.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e11c0a9398ded4411bf21510352c37c6) Choose a data source and start discovery **1. Open Discovery logs** Navigate to **Asset discovery** > **Discovery logs**. **2. Select Initiate discovery** Select **Initiate discovery**. **3. Choose data source** Select the **Data source** to discover, then select **Initiate discovery**. While discovery runs, the **Asset Discovery Log** shows progress for the selected source. The log walks through **Discovering assets**, then **Scan for matching assets**, so matching starts as part of the same run. ![Asset Discovery Log popup for New Furniture via KODE API showing Discovering assets in progress and Scan for matching assets as the next step](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-match-menu.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=b27784b70acbd36dc490bb0e5c8efd7c) Asset Discovery Log tracks discovering assets and the matching scan ### Review discovery results When discovery completes, select the arrow on the log row to open **Results: Asset Discovery**. The header shows the data source name and connector type (for example, **100 Assets - KODE API**). Two tabs organize results: | Tab | Description | | - | - | | **New assets** | Discovered records not yet in AssetOps for this building | | **Existing assets** | Discovered records that match assets already in the building | Use **Search**, **Filters**, and row checkboxes to work with the list. Select **Done** to exit without saving changes. #### Add new assets On the **New assets** tab, select assets to import. ![Results Asset Discovery New Assets tab with selected rows and Link with Existing and Add as New Assets buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-results-new.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=f08d700f1f2e5ac4054a8913799d957e) New assets tab with Link with Existing and Add as New Assets actions | Action | Description | | - | - | | **Link with existing** | Map new records to assets already in the building to avoid duplicates | | **Add as new assets** | Create new building assets from the selected discovered records | ##### Link with existing Select **Link with existing** to open the **Link with existing assets** page. You can link with [autosuggest](#link-assets-using-autosuggest) or [manually](#link-assets-manually). > [!NOTE] > > Manual matching supports up to 50 selected assets at a time so the matching page does not require pagination. This limit does not apply to `Autosuggest`. ![Link with Existing screen showing Selected New Assets paired with Existing Assets dropdowns and Autosuggest button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-link-with-existing.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=03b1511c644f0f4f107b3f4c3c81669e) Map each new asset to an existing building asset manually or with autosuggest The page has two sides: * **Selected new assets** — Discovered records you selected on the left * **Existing assets** — Dropdown on the right for each building asset to link to Use **Reset all** to clear mappings, **Cancel** to exit without saving, or **Save** to confirm links. Merged fields follow [field mapping](#field-mapping) priorities. ![Linking assets in progress and Linking completed successfully toasts with Go to Assets link](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-linking-toasts.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=df3afdc2a338dd1a6d59db736186cea8) Toast notifications show linking progress and completion with link to Assets When linking finishes, **Linking completed successfully** shows how many assets linked. Select **Go to Assets** to open the [Assets](/products/assetops/assets/assets) list. #### Update existing assets On the **Existing assets** tab, select records to update with values from the discovery run. ![Results Asset Discovery Existing Assets tab with Name, Category, Model Number, Type, and Located In columns and Update Assets button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-results-existing.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=979cbf59b121986e449c54d26cd5ed61) Existing assets tab lists matched assets with Update Assets action Select **Update assets** to apply field values from discovery to the selected building assets. A confirmation dialog shows how many assets you selected. ![Update Existing Assets modal asking to confirm updating four selected discovered assets](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-update-existing-confirm.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=00747f182213fc38cb97646cdbd4061d) Confirm before updating discovered values on existing building assets Select **Yes, confirm** to apply updates, or **Cancel** to return to the results screen. Updated assets reflect [field mapping](#field-mapping) priorities when multiple sources supply the same field. *** ## Configurations **Configurations** control how discovery maps and matches imported assets. Set up configurations before you run discovery and link assets so field updates and duplicate checks behave predictably. Select **Asset discovery** > **Configurations** in the building sidebar. The page has two tabs: **Field mapping** and **Matching rules**. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Asset fields"] F3["Field 1"] F4["Field 2"] F5["Field 3"] end subgraph s2["Data sources"] D1["Data source 1"] D2["Data source 2"] D3["Data source 3"] end FM["Field mapping"] --- AF["Asset fields"] AF --- F3 & F4 & F5 F4 -- priority --- D1 F4 --- D2 & D3 F3:::Sky F4:::Sky F5:::Sky D1:::Rose D2:::Rose D3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#FF6D00,fill:none ``` ### Field mapping Field mapping defines which data source is the primary source of truth for each asset field (name, serial number, location, and others). For every field, you maintain a priority list of data sources. When two assets link, AssetOps fills each field with the highest-priority value that exists between the linked records. If a field has no sources in its priority list, that field is not updated during linking. ![Configurations Field Mapping tab showing Name field expanded with KODE API source priority and Add Source button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-configurations-field-mapping.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a632b138bc8626505936dd1ecca87c2c) Field mapping lists 33 asset fields with expandable source priority per field **1. Open Field mapping** Navigate to **Asset discovery** > **Configurations** and stay on the **Field mapping** tab. **2. Expand a field** Select a field card to expand it and view current source priorities. **3. Add a source** Select **+ Add source**. In the **Add source** dialog, choose a data source from the dropdown, then select **Save**. The source appears in the field list. **4. Set priority** Drag sources to reorder priority. The system uses data from the highest-priority source that has a value between the linked assets. Remove a source with the minus icon when it should no longer apply to that field. After you upload a template in [Data sources](#data-sources), fields typically show **KODE API** as the source. #### Mappable fields (33) AssetOps supports field mapping for these asset attributes: | Field | Field | Field | | - | - | - | | Name | Category | Model number | | Serial number | IP address | MAC address | | Installation date | Warranty date | Commission date | | Turnover date | Asset tag | Initial cost | | Weight | Life expectancy | Location | | Belt size | Filter size | Power | | Tonnage | Amps | Volts | | RPMs | Status | Manufactured by | | Repair cost | Replacement cost | Firmware version | | OS version | Type | Located in | | Commissioned by | Installed by | Serviced by | ### Matching rules Matching configuration drives automatic and manual [duplicate checks](#link-assets-using-autosuggest). Profiling inspects completeness, uniqueness, and how fields are shared across sources, then recommends fields and match settings for the site. Strong identifiers are preferred when the data supports them. Blank or generic values (for example, `N/A`, `0.0.0.0`, or `00:00:00:00:00:00`) are ignored. The matching engine compares identifiers and names across common formatting differences (spaces, hyphens, underscores, and reordered tokens). Suggestions include a **match score** so stronger candidates surface first. Each matching rule contains up to three conditions. Every condition must be true for the rule to suggest a link. One rule must be the default so automatic and on-demand checks always have a baseline configuration. ![Configurations Matching Rules tab showing Exact match by Name default rule with Field Name and Match Type columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-configurations-matching-rules.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=abe7fe38d6b2075e98d77321264bdd9f) Matching rules list default and custom rules with conditions #### Match types | Match type | Behavior | | - | - | | **Match** | Case-insensitive comparison (`abc` matches `ABC`) | | **Exact match** | Case-sensitive comparison (`abc` matches only `abc`) | #### Default rule The system creates a default rule with a field and match type for baseline checks. Duplicate checks use the default when you do not select another rule. Profiling may suggest different fields for a given site; accept or adjust those suggestions when you run a manual check. > [!WARNING] > > A default matching rule must always exist and cannot be deleted. Duplicate checks require a default rule to run. #### Create a matching rule ![Add Rule modal with Rule Name, Description, Rule Conditions with Field Name and Match Type dropdowns, and Set as default rule for Autosuggest checkbox](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-configurations-add-rule.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=aef1055074ba035fb1c53bcc8f524746) Define rule name, description, and conditions with field and match type **1. Open Matching rules** Navigate to **Asset discovery** > **Configurations** and select the **Matching rules** tab. **2. Select + Add rule** Select **+ Add rule** in the upper right corner. **3. Enter rule details** Enter a unique **Rule name** and **Description**. **4. Add conditions** For each condition, set **Field name** (for example, serial number) and **Match type**. Select **+ Add condition** for up to three conditions total. Use profiling suggestions when they appear so you prioritize fields with strong coverage for this data source. **5. Save the rule** Select **Save**. Enable **Set as default rule for autosuggest** if this rule should become the default. #### Designate a default matching rule **1. Open the rule menu** In the matching rules list, select the three-dot menu on the rule row. **2. Edit the rule** Select **Edit**. **3. Set default** Enable **Set as default rule for autosuggest**, then select **Save**. You can also enable **Set as default rule for autosuggest** when you create a new rule. #### Edit a matching rule **1. Open the rule menu** Select the three-dot menu on the rule row, then select **Edit**. **2. Update and save** Change rule settings as needed, then select **Save**. Select **Cancel** to discard changes. #### Delete a matching rule **1. Open the rule menu** Select the three-dot menu on the rule row, then select **Delete**. **2. Confirm deletion** In the **Delete matching rule** dialog, select **Delete** to confirm or **Cancel** to keep the rule. You cannot delete the default matching rule. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Condition 1"] Field1["Field"] Match1["Match type"] end subgraph s2["Condition 2"] Field2["Field"] Match2["Match type"] end MR["Matching rules"] --- R1["Rule 1"] R1 --- s1 & s2 Field1:::Rose Field2:::Rose R1:::Sky classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 ``` *** ## Asset linking Link newly discovered assets with existing building assets to merge information and prevent duplicate entries. See [Concepts and rationale](#concepts-and-rationale) for how duplicate checks, scored suggestions, confirmation, and manual linking work together. Discovery starts an automatic duplicate check when assets are ingested. You can also run checks on demand for selected items or the full result set. You can start linking from the **New assets** tab in [Review discovery results](#review-discovery-results), or select **Asset discovery** > **Asset linking** in the building sidebar. ### Link assets using autosuggest Use **Autosuggest** to fill **Existing assets** on the right from the duplicate check. The review list highlights the **best match** for each discovered asset. Expand a row to see alternative scored candidates when the top suggestion is wrong. Filter by match score, category, type, or area to focus the list. Confirm high-confidence links in bulk, then save. ![Link with Existing screen showing selected new assets on the left, existing asset dropdowns on the right, and Autosuggest button in the header](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-link-with-existing.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=03b1511c644f0f4f107b3f4c3c81669e) Link with existing assets page with Autosuggest and per-row existing asset dropdowns **1. Open discovery results** Navigate to **Asset discovery** > **Discovery logs**. Run **Initiate discovery** or open a completed log with the arrow icon to reach **Results: Asset Discovery** on the **New assets** tab. **2. Select assets** Select discovered assets to link. You can limit the selection to run a check on selected items only. **Link with existing** becomes active. **3. Open Link with existing** Select **Link with existing**. The **Link with existing assets** page opens with selected new assets on the left and existing asset fields on the right. **4. Run Autosuggest or configure the check** Select **Autosuggest** to run with the current configuration. To choose fields or a rule, open the configuration next to **Autosuggest**, review profiling suggestions, pick a [matching rule](#matching-rules) or fields, then select **Save**. If you do not change the configuration, the [default matching rule](#default-rule) applies. ![Autosuggest Configurations modal with Exact match by Name default rule and Go to Configs button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-autosuggest-config.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=bc0b734631150fdb2d8bc8f6fe49e301) Autosuggest configurations modal to pick a matching rule or open Configurations | Control | Description | | - | - | | Matching rule / fields | Rules and fields from [Matching rules](#matching-rules), with profiling suggestions when available | | **Go to Configs** | Opens **Configurations** to edit rules | | **Save** | Applies the selected configuration and runs the duplicate check | **5. Filter and review suggestions** Filter suggestions by score range (for example, above 90%), category, type, or area. Review the highlighted best match on each row. Expand alternatives when you need a different candidate. Adjust any mapping with the existing asset dropdown. **6. Run the check again when needed** If matches look weak, run the duplicate check again. Profiling identifies which fields have the strongest coverage for the data source so the next check can use better criteria. **7. Save or pause** Select **Save** to confirm links. Linked asset fields update using [field mapping](#field-mapping) priorities. Use **Close for now** to leave the session and finish linking later. Use **Reset all** to clear mappings, or **Cancel** to exit without saving. After you confirm links in bulk, linked assets leave the **New assets** list. ### Link assets manually Use manual linking when scored suggestions do not fit or you need precise control. For each new asset on the left, search and select the correct building asset from the **Existing assets** dropdown on the right. Filters on the existing-asset picker narrow the inventory so you do not search the full building list. ![Link with Existing screen with new assets on the left and Existing Assets dropdown fields on the right for manual pairing](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-discovery-link-with-existing.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=03b1511c644f0f4f107b3f4c3c81669e) Manually map each new asset to an existing asset using the Existing assets dropdown **1. Open discovery results** Navigate to **Asset discovery** > **Discovery logs**. Open **Results: Asset Discovery** on the **New assets** tab. **2. Select assets** Select assets, then select **Link with existing**. **3. Map each pair** For each new asset on the left, select the matching existing asset from the dropdown on the right. Use search and filters on the picker when the list is large. **4. Save links** Select **Save** to link the assets. Fields update per [field mapping](#field-mapping). Use **Close for now**, **Reset all**, or **Cancel** as needed. After linking, verify merged fields on the [Assets](/products/assetops/assets/assets) page and in the asset **Sources** tab. *** ## Related modules > [card] [Assets](/products/assetops/assets/assets) > > View and manage assets after discovery completes. # Assets Source: https://docs.kodelabs.com/products/assetops/assets/assets View and manage building assets in AssetOps The **Assets** section at the [building level](/products/assetops/quickstart/usage-workflow#building-level) is the hub for assets in a building. The list shows only assets with status `Active` or `Out of service`. Open a building from [Buildings](/products/assetops/resources/buildings), then select **Assets** from the building sidebar. *** ## Asset list The assets table displays key information for each asset. Use the search bar to filter by name or other values. Select **Filters** to narrow the list by category, type, area, or status. Use the column control at the right edge of the header row to show or hide columns. ![Building Assets table with search bar, Filters button, and columns Name, Category, Type, Model Number, Area, and Active status](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-assets-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=470d99beb6820b3c668c814fa103f24f) Assets list with search, filters, and columns for Name, Category, Type, Model number, Area, and Status | Column | Description | | - | - | | Name | The asset name | | Category | Equipment, Architectural, or Furniture | | Type | The specific asset type (for example, AHU, VAV, Boiler) | | Model number | Manufacturer model number | | Area | The building area where the asset is located | | Status | `Active` or `Out of service`. The list shows only these statuses. | *** ## Bulk edit assets Update multiple assets at once from the list. Select one or more rows, then select **Edit**. ![Assets list with multiple rows selected showing Edit and Delete actions in the header](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-assets-bulk-select.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=2d157b36a8429ca4b7ff948ca382dbcf) Select assets with checkboxes, then use Edit to open the bulk edit modal The **Edit assets** modal opens. Enable the checkbox next to each field you want to change. Only checked fields are updated on all selected assets. > [!WARNING] > > Any changes you save apply to every selected asset. Review your selection count before you save. ![Edit Assets modal with warning banner, Category Type and Area dropdowns, and Location IP Address Model Number Installation Date fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-assets-edit-modal.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=1deb77fb27eb94c39df8820c35d65957) Edit assets modal with field checkboxes and unit selectors for measurements and currency **1. Select assets** Use row checkboxes or the header checkbox to select assets in the list. **2. Open Edit assets** Select **Edit** in the toolbar. **3. Choose fields to update** Enable the checkbox for each field you want to change. Enter or select values only for checked fields. **4. Save changes** Select **Save** to apply updates to all selected assets, or **Cancel** to close without saving. ### Bulk-editable fields The modal supports the fields below. Dropdown fields use **Select an option**. Text fields use **Enter**. Date fields use the date picker (`mm/dd/yyyy`). **Classification and location** **Category** `Dropdown` Asset category (for example, Equipment). **Type** `Dropdown` Asset type within the category (for example, VAV, AHU). **Area** `Dropdown` Building area where the asset is located. **Location** `Field` Specific location description within the area. **Identification and network** **IP address** `Field` Network IP address for the asset. **Model number** `Field` Manufacturer model number. **Dates** **Installation date** `Date` Date the asset was installed. **Warranty date** `Date` Warranty expiration date. **Commission date** `Date` Date the asset was commissioned. **Turnover date** `Date` Date the asset was turned over to operations. **Asset tag** `Field` Unique identifier tag for the asset. **Physical and lifecycle** **Weight** `Field` Asset weight. Choose units: **lb** or **Pounds**. **Life expectancy** `Field` Expected useful life. Choose units: **day** or **Days**. **Status** `Dropdown` Operational status (for example, Active, Out of Service, Decommissioned). **Technical specifications** **Belt size** `Field` Belt dimensions. Units: **in**. **Filter size** `Field` Filter dimensions. Units: **in**. **Tonnage** `Field` Cooling capacity in tons. **Power** `Field` Power rating. Choose units: **hp**. **Amps** `Field` Electrical current draw. **Volts** `Field` Operating voltage. **RPMs** `Field` Rotational speed. **Financial** **Initial cost** `Field` Original purchase cost. Currency: **USD** or **USD (\$)**. **Repair cost** `Field` Cost of last repair. Currency: **USD** or **USD (\$)**. **Replacement cost** `Field` Estimated replacement cost. Currency: **USD** or **USD (\$)**. **Software and vendors** **Firmware version** `Field` Device firmware version. **OS version** `Field` Operating system version. **Manufactured by** `Field` Manufacturer name. **Commissioned by** `Field` Vendor that commissioned the asset. **Installed by** `Field` Vendor that installed the asset. **Serviced by** `Field` Vendor that services the asset. > [!NOTE] > > Bulk edit does not include every field on the asset detail page. Fields such as **Serial number** and **MAC address** are available when you edit a single asset. *** ## View asset details Select an asset **Name** from the list to open the asset detail page. Breadcrumbs show **Buildings** > building name > **Assets** > asset name. The page header displays the asset name, a back control to return to the list, and tags such as **Cloud BMS Device** when the asset is linked to KODE OS. Three tabs appear below the header: | Tab | Purpose | | - | - | | **Details** | Asset fields, technical specs, and related schedules and work orders | | **Sources** | Data sources linked to the asset | | **Attachments** | Files attached to the asset record | ### Details tab ![Asset detail page Details tab with General information including Name, Category, network fields, dates, costs, vendors, and Active status](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-details.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=1f83868c4ff5d1f1462311c5c23b2b4a) Asset Details tab showing General information fields for a VAV asset ### General information The **General information** section lists core asset attributes in a grid. Select the icon in the section header to edit these fields on this asset. | Field | Description | | - | - | | Name | Asset name. An external-link icon opens the linked Cloud BMS device when applicable. | | Category | Equipment, Architectural, or Furniture | | Type | Specific asset type within the category (for example, VAV, AHU) | | Location | Specific location description within the building | | IP address | Network IP address | | MAC address | Network MAC address | | Model number | Manufacturer model number | | Serial number | Manufacturer serial number | | Installation date | Date the asset was installed | | Warranty date | Warranty expiration date | | Commission date | Date the asset was commissioned | | Turnover date | Date turned over to operations | | Asset tag | Unique identifier tag | | Weight | Asset weight (for example, `100lb`) | | Status | Active, Out of Service, or Decommissioned | | Life expectancy | Expected useful life (for example, `100d`) | | Manufactured by | Manufacturer name | | Commissioned by | Vendor that commissioned the asset | | Installed by | Vendor that installed the asset | | Serviced by | Vendor that services the asset | | Initial cost | Original purchase cost | | Repair cost | Cost of last repair | | Replacement cost | Estimated replacement cost | | Firmware version | Device firmware version | | OS version | Operating system version | ### Located in **Located in** shows where the asset sits in the building hierarchy (for example, floor, zone, or space). The value displays as a dash when no location hierarchy is assigned. ### Technical specifications **Technical specifications** lists HVAC and electrical ratings separate from general information. | Field | Example format | | - | - | | Belt size | `12 in` | | Filter size | `12 in` | | Tonnage | `122 TR` | | Power | `1222 hp` | | Amps | `123 A` | | Volts | `123 V` | | RPMs | `1234 RPM` | ### Schedules and work orders The **Schedules and work orders** section shows maintenance activity tied to the asset. Two sub-tabs organize the content: | Sub-tab | Content | | - | - | | **Schedules** | [Preventive maintenance and inspection schedules](/products/assetops/schedules/schedules-overview) linked to this asset | | **Work orders** | Work order summary and status for this asset | On the **Work orders** sub-tab you see: * **Work orders by status** — Chart of work orders grouped by status. Shows **No data here** when no work orders exist for the asset. * **Completed work orders** — Count of completed work orders (for example, `0 of 0`). * **Overdue work orders** — Count of overdue work orders (for example, `0 of 0`). * **External push work orders** — Work orders pushed from external systems to this asset. Select a schedule or work order entry to open its detail page. For building-wide work order tasks, see [work orders](/products/assetops/work-orders/work-orders-overview). ### Sources tab The **Sources** tab lists each [data source](/products/assetops/assets/asset-discovery) record linked to the asset. Use this tab to verify how discovery and [asset linking](/products/assetops/assets/asset-discovery#asset-linking) mapped the asset in external systems. ![Asset Sources tab showing linked source VAV\_304 with identifier h:c4c5 and data source jace](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-sources.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=bb22d22a9404c3f8123736d3675bd746) Sources tab table with Name, Identifier, and Data source columns | Column | Description | | - | - | | Name | Display name for the linked source record. Select the name to open source details. | | Identifier | Unique ID for the record in the data source (for example, `h:c4c5`). | | Data source | Connector or import source name (for example, `jace`). | Info icons next to column headers provide additional context in the UI. #### View linked source details Select a **Name** link in the table to open a read-only modal for that source record. ![Source detail modal for VAV\_304 with General tab showing Identifier h:c4c5 and Name VAV\_304](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-source-detail.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=b5cb7ed306b58436f7e1f93c5bebfc5f) Source detail modal with General, Identifiers, Custom Tags, and Custom Properties tabs The modal includes four tabs: | Tab | Content | | - | - | | **General** | Core identifiers and device metadata from the source | | **Identifiers** | Additional IDs assigned by the source system | | **Custom tags** | Tags imported from the source | | **Custom properties** | Extended properties from the source | On the **General** tab you can review: | Field | Description | | - | - | | Identifier | Source-system ID (for example, `h:c4c5`) | | Name | Record name in the source (for example, `VAV_304`) | | MAC address | MAC address from the source | | IP address | IP address from the source | | Manufacturer | Manufacturer reported by the source | | Model | Model reported by the source | | Firmware version | Firmware version from the source | | OS version | Operating system version from the source | Empty values display as a dash. Select **Close** to return to the **Sources** tab. ### Attachments tab The **Attachments** tab stores files related to the asset, such as manuals, photos, or inspection documents. ![Asset Attachments tab showing Upload button and an attachment card with date, uploader, and filename](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-asset-attachments.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=85049d15663b900c7f35ef5eef0aa6d9) Attachments tab with Upload button and file cards * Select **Upload** to add a new file to the asset. * Each attachment card shows the upload date, uploader name, file name, and a preview icon. * Select the vertical ellipsis menu on a card for additional file actions. *** ## Manage a single asset From the asset detail page you can complete the following actions: * Select the icon on **General information** to edit fields for this asset only * Use the icon in the upper right corner to delete or decommission the asset * Review schedules and work orders in the **Schedules and work orders** section * Open the **Sources** tab to verify linked data sources, or the **Attachments** tab to upload and manage files *** ## Next steps > [card] [Onboard assets](/products/assetops/assets/asset-discovery) > > Import and discover new assets for your building using data sources. > [card] [Link assets](/products/assetops/assets/asset-discovery#asset-linking) > > Link and deduplicate assets from multiple data sources. > [card] [Asset fields](/products/assetops/reference/asset-fields) > > Look up every asset field, column, and technical specification. # Building dashboard Source: https://docs.kodelabs.com/products/assetops/building/dashboard Monitor maintenance activity and performance for a single building in AssetOps The **Dashboard** at the [building level](/products/assetops/quickstart/usage-workflow#building-level) summarizes maintenance operations for the building you selected. Open it after you choose a building from [Buildings](/products/assetops/resources/buildings) at the portfolio level. Metrics on the building dashboard roll up to the [portfolio dashboard](/products/assetops/portfolio/dashboard) for cross-site reporting. ## Dashboard views The building dashboard includes four views. Select a tab at the top of the page to change the analysis: * **Operations** — Work order status, team and assignee workload, creation patterns, and SLA performance * **Time analysis** — Logged hours, estimated versus actual time, and response and completion targets * **Forecast** — Upcoming scheduled work for the building * **Historical trends** — Volume, completion rate, and time-to-close trends over time The **Operations** view is the default starting point for day-to-day site oversight. ## Filter the dashboard Use the filter bar to narrow results for the selected building. Filters apply across **Operations**, **Time analysis**, **Forecast**, and **Historical trends** so KPIs and charts stay aligned. Available filters vary by view but commonly include: * **Created date** — Date range for work included in the charts (for example, last 30 days). Your selected range stays for the session when you leave and return. You can return to the default range. * **Team** — One or more [teams](/products/assetops/resources/teams) at the building * **Assignee** — Individual staff members * **Work type** — Maintenance program (preventive maintenance, inspections, corrective maintenance, service requests) * **Category** — [Category](/products/assetops/resources/categories) assigned to work orders ### Overdue Only Enable **Overdue Only** on the Operations dashboard to recalculate every KPI and chart for overdue work only. Overdue is a work state based on the due date, not a single lifecycle status. The toggle includes overdue work that is still in progress and completed work that was overdue. ## Operations view The Operations view summarizes building health with KPI cards, completion rates, and team and assignee workload. Scroll below the workload section for work order creation patterns, category breakdowns, and SLA and priority charts. ![Building dashboard Operations view with KPI summary cards, completion rate metrics, filter bar, and workload by team and assignee panels](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-operations.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=54899c5d6359a6e0d1e761474a963a95) The Operations view shows KPI cards, completion rates, and workload by team and assignee ### KPI summary The top row of cards highlights current work order status and SLA outcomes for the building: | Metric | Purpose | | - | - | | Open work orders | Work still in progress at this building | | Completed work orders | Work closed in the selected period | | Overdue work orders | Work past its due date | | On hold | Work paused awaiting action | | Failed | Work that did not complete successfully | | SLA met | Work that met its SLA target | | SLA breached | Work that missed its SLA target | | Compliance rate | Overall SLA compliance percentage for the building | ### Completion rates Below the KPI row, completion rate tiles show progress by maintenance program, such as preventive maintenance, inspection completion, corrective maintenance, and service requests. ### Workload by team and assignee The **Workload** section shows how open work is distributed. Toggle each panel to view by **Status**, **Work type**, or **Priority**. * **Workload by team** — Lists each team with total tasks and a bar chart of status distribution (open, in progress, completed, on hold, for review, canceled) * **Workload by assignee** — Lists each staff member with the same status breakdown for assigned work Use these panels to balance assignments across [teams](/products/assetops/resources/teams) and identify bottlenecks before work becomes overdue. ### Work order creation patterns The **Work order creation patterns** heatmap shows when work orders are created across days of the week and time of day for this building. Darker cells indicate higher volume. ![Building work order creation patterns heatmap by day and time block with peak metrics and expandable corrective maintenance category list](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-creation-patterns.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e9ba3adc42ec6abe6cefebc659abcbb6) The creation patterns heatmap and corrective maintenance category breakdown for the selected building Summary cards below the heatmap typically include peak day, peak time, average daily work orders, and weekend average for the filtered period. ### Breakdown by category and issue type The **Work orders breakdown by category and issue type for corrective maintenance** section lists corrective maintenance volume by category. Expand a category to view issue types within that category. ### SLA and priority The **SLA and priority** section shows how work orders at this building align with SLA targets and assigned priority levels. ![Building SLA and Priority section with donut charts for SLA status distribution and priority distribution](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-sla-priority.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=d4d671f353a2794547c3dba7fe44cbea) Donut charts compare SLA status and priority distribution for the building Configure portfolio-wide rules in [Priority & SLA](/products/assetops/portfolio/priority-sla). Building results reflect how that building performs against those targets. ## Time analysis view The **Time analysis** view tracks labor hours logged against work orders at the building. ![Building dashboard Time Analysis view with total hours logged, estimated versus actual working hours chart, and hours by work type stacked area chart](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-time-analysis.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=95a403daa33134eb4efe3c3e39dcfd35) Time analysis shows logged hours, estimated versus actual time, and hours by work type ### Summary metrics The top row typically includes: * **Total hours logged** — Sum of time entries in the filtered period * **Average hours per work order** — Mean logged time per work order * **Planned work** — Share of hours tied to preventive maintenance programs * **Estimated versus actual work** — Comparison of estimated hours to logged hours ### Estimated versus actual working hours This section compares estimated hours on work orders to actual hours logged over time. Summary cards show how many work orders include estimates and how many have logged time. ### Hours by work type The **Hours by work type** chart shows how logged hours distribute across preventive maintenance, inspections, corrective maintenance, and service requests over the selected period. ### Response, completion, and category hours Scroll below the charts for additional time analysis tables. ![Response and completion time table by priority level and hours by category and issue type list for the building](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-time-analysis-metrics.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a77cfc82c431d2e422615fae6aa8c434) Response and completion targets by priority, with hours summarized by category * **Response and completion time** — Lists each priority with total orders, average response and completion times, and target response and completion goals * **Hours by category and issue type** — Summarizes logged hours, completion share, and work order count per category; expand rows for issue type detail ## Forecast view The **Forecast** view projects upcoming scheduled work for the building. ![Building dashboard Forecast view with upcoming work order counts, estimated hours, and workload timeline chart for preventive maintenance and inspections](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-forecast.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=9e9f84d67f3112279d3412ca60caac56) Forecast shows upcoming work orders and estimated hours over the next several weeks Use filters such as **Weeks** (for example, next four weeks) and **Team** to scope the projection. Summary metrics typically include: * **Upcoming work orders** — Total scheduled work with breakdown by program (for example, preventive maintenance and inspections) * **Total estimated hours** — Planned labor for upcoming work The **Workload timeline** chart shows how upcoming preventive maintenance and inspection work orders distribute across the forecast window. Summary cards on the left list counts and hours by program. ## Historical trends view The **Historical trends** view shows longer-term patterns for work volume and completion at the building. ![Building dashboard Historical Trends view with average time to close chart, completion rate by work type, and created versus open work orders bar chart](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-dashboard-historical-trends.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a7e1530c31417ec03403d1a78906d3b3) Historical trends show time to close and created versus open work orders over time ### Summary metrics The top row typically includes total work orders, volume trend, average completion rate, and planned work percentage for the filtered period. ### Average time to close The **Average time to close** chart tracks how long work takes to close over time. Summary cards below break out average days to close by work type, such as preventive maintenance, inspections, corrective maintenance, and service requests. ### Created versus open work orders The **Created versus open work orders** section compares work created in the period to work still open versus closed. Summary cards list total created, still open, and closed counts. The chart shows open and closed volumes over time. ## When to use the building dashboard Use the building dashboard for day-to-day operations at a single site. Return to the portfolio level when you need comparisons across buildings or portfolio-wide configuration such as [vendors](/products/assetops/resources/vendors) or [priority & SLA](/products/assetops/portfolio/priority-sla). ## Related modules > [card] [Work orders](/products/assetops/work-orders/work-orders-overview) > > Create and manage corrective maintenance for this building. > [card] [Assets](/products/assetops/assets/assets) > > View and manage equipment, systems, and locations for this building. > [card] [Schedules](/products/assetops/schedules/schedules-overview) > > Plan preventive maintenance and inspections for this building. > [card] [Teams](/products/assetops/resources/teams) > > Organize assignees whose workload appears on the dashboard. # KODE glossary Source: https://docs.kodelabs.com/products/assetops/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Portfolio dashboard Source: https://docs.kodelabs.com/products/assetops/portfolio/dashboard Monitor portfolio-wide maintenance performance and activity in AssetOps The **Dashboard** at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) gives you a single view of maintenance operations across every building in your portfolio. Use it to track open work, schedule compliance, SLA performance, and trends without opening each site individually. ## Dashboard views The portfolio dashboard includes four views. Select a tab at the top of the page to change the analysis: * **Operations** — Work order volume, status, compliance, and distribution by maintenance type * **Time analysis** — Logged hours, estimated versus actual time, and hours by work type * **Forecast** — Forward-looking workload projections * **Historical trends** — Longer-term performance over time The **Operations** view is the default starting point for day-to-day portfolio oversight. ## Filter the dashboard Use the filter bar below the view tabs to narrow results. Filters apply across **Operations**, **Time analysis**, **Forecast**, and **Historical trends** so KPIs and charts stay aligned. The same **Region** filter logic is available on [portfolio work orders](/products/assetops/portfolio/work-orders) and [portfolio schedules](/products/assetops/portfolio/schedules). Available filters include: * **Created date** — Date range for work included in the charts (for example, last 30 days). Your selected range stays for the session when you leave and return. You can return to the default range. * **Building** — One or more buildings in the portfolio * **Region** — Geographic or organizational grouping that scopes every metric and list to that part of the portfolio * **Property type** — Building category * **Work type** — Maintenance program (preventive maintenance, inspections, corrective maintenance, service requests) * **Category** — Portfolio [category](/products/assetops/resources/categories) assigned to work orders * **Status** — Open, completed, and other workflow statuses Available filters vary slightly by view. For example, the **Forecast** view uses **Weeks** instead of **Created date**. ### Overdue Only Enable **Overdue Only** on the Operations dashboard to recalculate every KPI and chart for overdue work only. Overdue is a work state based on the due date, not a single lifecycle status. The toggle includes overdue work that is still in progress and completed work that was overdue. Use **Overdue Only** with **Region** (and other filters) when you need overdue backlog by geography. ## Operations view The Operations view summarizes portfolio health with KPI cards, completion rates, work distribution over time, creation patterns, category breakdowns, and SLA and priority charts. ![Portfolio dashboard Operations view with KPI summary cards, completion rate metrics, filter bar, and stacked area chart for work distribution by type](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-dashboard-operations.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=649c9260990e058cb314334f090b8341) The Operations view shows KPI cards, completion rates, and work distribution by maintenance type ### KPI summary The top row of cards highlights current work order status and SLA outcomes: | Metric | Purpose | | - | - | | Open work orders | Work still in progress across the portfolio | | Completed work orders | Work closed in the selected period | | Overdue work orders | Work past its due date | | On hold | Work paused awaiting action | | Failed | Work that did not complete successfully | | SLA met | Work that met its [SLA](/products/assetops/portfolio/priority-sla) target | | SLA breached | Work that missed its SLA target | | Compliance rate | Overall SLA compliance percentage | ### Completion rates Below the KPI row, completion rate tiles show progress by maintenance program, such as preventive maintenance, inspections, corrective maintenance, and service requests. Use these tiles to compare planned versus reactive workload completion across the portfolio. ### Work distribution by type The **Work distribution by type** chart displays how work order volume changes over the selected date range. Stacked areas represent preventive maintenance, inspection work orders, corrective maintenance work orders, and service requests. Summary boxes below the chart list total work order counts for each type in the filtered period. Use this section to see which programs drive the most volume portfolio-wide. ## Work order creation patterns The **Work order creation patterns** heatmap shows when work orders are created across days of the week and time of day. Darker cells indicate higher volume. ![Work order creation patterns heatmap by day and three-hour time blocks, with peak day and time summary cards and expandable corrective maintenance category list](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-dashboard-creation-patterns.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=ba7a01338eaf7cc4fb321c8cafa92ab0) The creation patterns heatmap shows peak days and times, with a corrective maintenance breakdown by category below Summary cards below the heatmap typically include: * **Peak day** — The day of the week with the highest creation volume * **Peak time** — The time block with the highest creation volume * **Average daily work orders** — Mean creations per day in the filtered period * **Weekend average** — Mean creations on weekends Use these metrics to align staffing and dispatch with when work enters the system. ### Breakdown by category and issue type The **Work orders breakdown by category and issue type for corrective maintenance** section lists corrective maintenance volume by [category](/products/assetops/resources/categories). Each row shows the category name, work order count, and share of corrective maintenance work. Expand a category to view issue types within that category. Use this breakdown to identify recurring problem areas across the portfolio. ## SLA and priority The **SLA and priority** section shows how work orders in the filtered set align with SLA targets and assigned priority levels. ![SLA and Priority section with two donut charts for SLA status distribution and priority distribution totaling 1.2K work orders](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-dashboard-sla-priority.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=7866ddc207fe4dca57e0fe3a30dee0a1) Donut charts compare SLA status and priority distribution for the filtered work order set ### SLA status distribution The SLA status chart groups work orders by SLA outcome, such as: * **SLA met** — Completed within the defined SLA window * **On track** — Open work still within SLA * **Breached** — Open or closed work that missed SLA * **No SLA** — Work without an assigned SLA target Configure SLA rules in [Priority & SLA](/products/assetops/portfolio/priority-sla). ### Priority distribution The priority distribution chart shows how work is spread across priority levels, including standard priorities and specialized priorities such as cleaning. Use this chart with the SLA chart to see whether high-priority work is meeting targets. ## Time analysis view The **Time analysis** view tracks labor hours logged against work orders across the portfolio. ![Portfolio dashboard Time Analysis view with total hours logged, estimated versus actual working hours chart, and hours by work type stacked area chart](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-dashboard-time-analysis.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=d14429fed647887e8479cb67885c062b) Time analysis shows logged hours, estimated versus actual time, and hours by work type portfolio-wide ### Summary metrics The top row typically includes: * **Total hours logged** — Sum of time entries in the filtered period across all buildings * **Average hours per work order** — Mean logged time per work order * **Planned work** — Share of hours tied to preventive maintenance programs * **Estimated versus actual work** — Comparison of estimated hours to logged hours ### Estimated versus actual working hours This section compares estimated hours on work orders to actual hours logged over time. Summary cards show how many work orders include estimates and how many have logged time portfolio-wide. Use this chart to spot periods where actual labor significantly exceeds estimates. ### Hours by work type The **Hours by work type** chart shows how logged hours distribute across preventive maintenance, inspections, corrective maintenance, and service requests over the selected period. Use it to see which programs consume the most labor across the portfolio. ## Forecast view The **Forecast** view projects upcoming scheduled work across buildings in the portfolio. ![Portfolio dashboard Forecast view with building count, total work orders, PM and inspection counts, and work orders count by buildings table](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-dashboard-forecast.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=0e8912e621df444a00449d718dc6b363) Forecast aggregates upcoming preventive maintenance and inspection work orders by building Use filters such as **Weeks** (for example, next four weeks) and **Building** to scope the projection. ### Summary metrics The top row typically includes: * **Total buildings** — Buildings included in the forecast * **Total work orders** — Upcoming scheduled work across the portfolio * **PM work orders** — Upcoming preventive maintenance count * **Inspection work orders** — Upcoming inspection count * **Average capacity** — Average capacity used across buildings in the period ### Work orders count by buildings The **Work orders count by buildings** table lists each building with: * **PM and inspection work orders** — Breakdown of upcoming preventive maintenance versus inspections * **Capacity used %** — Share of available capacity consumed by scheduled work * **Total work orders** — Combined upcoming count for the building Use this table to compare upcoming workload across sites and identify buildings with heavy scheduled volume. ## Historical trends view The **Historical trends** view shows longer-term patterns for work volume and completion across the portfolio. ![Portfolio dashboard Historical Trends view with average time to close chart, completion rate by work type, and created versus open work orders bar chart](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-dashboard-historical-trends.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=18eb3d71bdac4dcd7d02be1e9dd0d820) Historical trends show time to close and created versus open work orders portfolio-wide ### Summary metrics The top row typically includes total work orders, volume trend, average completion rate, and planned work percentage for the filtered period. ### Average time to close The **Average time to close** chart tracks how long work takes to close over time across the portfolio. Summary cards below break out average days to close by work type, such as preventive maintenance, inspections, corrective maintenance, and service requests. ### Created versus open work orders The **Created versus open work orders** section compares work created in the period to work still open versus closed. Summary cards list total created, still open, and closed counts. The chart shows open and closed volumes over time so you can see backlog growth or reduction portfolio-wide. ## When to use the portfolio dashboard Use the portfolio dashboard when you oversee multiple buildings and need cross-site visibility. Select a building from [Buildings](/products/assetops/resources/buildings) when you need site-specific detail in the [building dashboard](/products/assetops/building/dashboard). ## Related modules > [card] [Buildings](/products/assetops/resources/buildings) > > Open a building to manage assets, work orders, and teams at the building level. > [card] [Work orders](/products/assetops/portfolio/work-orders) > > Review and filter work orders across the entire portfolio. > [card] [Schedules](/products/assetops/portfolio/schedules) > > Monitor recurring maintenance portfolio-wide. > [card] [Priority & SLA](/products/assetops/portfolio/priority-sla) > > Configure priority levels and SLA targets applied on the dashboard. # Priority and SLA Source: https://docs.kodelabs.com/products/assetops/portfolio/priority-sla Configure priority levels and SLA targets for work orders across your AssetOps portfolio **Priority & SLA** at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) defines how urgent work is classified and how quickly it must be completed. Priority levels rank work orders by urgency. Service level agreements (SLAs) set response and completion targets for each priority. These rules apply consistently across all buildings so teams and vendors share the same expectations. SLA results appear on the [portfolio dashboard](/products/assetops/portfolio/dashboard) and [portfolio work orders](/products/assetops/portfolio/work-orders) views. ## View priority and SLA configuration Open **Priority & SLA** from the portfolio sidebar to manage priority levels and SLA targets. ![AssetOps Priority and SLA Configuration table with Priority, Description, Status, Response SLA, and Completion SLA columns and Add Priority button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-priority-sla-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ae15e05d3ff1b877bab95e5b44add097) The Priority and SLA table lists each priority with description, status, and SLA targets The table includes: | Column | Description | | - | - | | **Priority** | Priority name with a color indicator | | **Description** | Internal notes such as team assignment and target workflow states | | **Status** | **Active** or inactive | | **Response SLA** | Time to acknowledge and assign the work order | | **Completion SLA** | Time to complete the work order | Use **Reorder** to change priority rank. Select **+ Add Priority** to create a new level. ### Default priority One priority can be marked **Default**. The default priority applies to new work orders when no priority is specified during creation. ## Create a priority level Creating a priority uses a two-step flow: **General info** and **SLA configuration**. ### Step 1: General info ![Create Priority Level modal step one General Info with Priority Name, Description, Color, and Default Priority toggle](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-priority-sla-create-step1.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ec7e0e62f4be8552b49a6ba125ff347c) Enter priority name, description, color, and default setting **Priority Name** `Field` *required* Display name for the priority level, such as Critical, High, or Medium - Cleaning. **Description** `Field` Optional notes for administrators, such as team ownership or internal priority codes. **Color** `Dropdown` *required* Color indicator shown on work orders and dashboards for this priority. **Default Priority** `Toggle` When enabled, auto-assigns this priority to new work orders when no priority is specified. **1. Select + Add Priority** On the **Priority & SLA** page, select **+ Add Priority**. **2. Enter general info** Enter **Priority name**, **Description**, and **Color**. Enable **Default priority** if this level should apply when none is selected. **3. Continue** Select **Next** to open SLA configuration. ### Step 2: SLA configuration ![Create Priority Level modal step two SLA Configuration with Response Time and Completion Time hour and minute fields](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-priority-sla-create-step2.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9f8ce0b669be0eaf24e33376159fb7c6) Set response time and completion time targets for the priority **Response Time** `Field` Time to acknowledge and assign the work order. Enter hours and minutes. **Completion Time** `Field` Time to complete the work order. Enter hours and minutes. > [!NOTE] > > If you skip SLA configuration, SLA status does not display for work orders with this priority. **1. Set response time** Enter the **Response time** in hours and minutes. **2. Set completion time** Enter the **Completion time** in hours and minutes. **3. Create the priority** Select **Create** to save the priority level. Select **Back** to change general info, or **Cancel** to exit without saving. ## Reorder priorities Priority **level** determines rank when users sort or triage work. Lower level numbers represent higher urgency. ![Reorder Priorities modal with drag handles showing Critical through Medium Cleaning with level numbers 1 through 7](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-priority-sla-reorder.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9cb2acc9724a0b23b4bef806c191378e) Drag priorities to change their level order **1. Select Reorder** On the **Priority & SLA** page, select **Reorder**. **2. Drag priorities** Use the drag handle on each row to move priorities up or down. **3. Save** Select **Save** to apply the new order. ## Edit a priority level Open the row menu on a priority and select **Edit** to update general info or SLA targets. ![Priority and SLA table row with Edit menu open showing Response SLA and Completion SLA columns](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-priority-sla-edit.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=3581cdc5c93fd3e62f11c1ec7c99513d) Use the row menu to edit response and completion SLA values You can change the name, description, color, default setting, status, and SLA times. Updates apply according to your organization's rules for new and in-progress work orders. ## How priority and SLA affect work orders Priority and SLA influence operations across AssetOps: * **Work order creation** — Users select a priority when they create or triage work. The default priority applies when none is chosen. * **SLA tracking** — Response and completion clocks compare elapsed time to configured targets. * **Dashboards** — [Portfolio](/products/assetops/portfolio/dashboard) and [building](/products/assetops/building/dashboard) dashboards show SLA met, breached, and compliance metrics. * **Routing** — Combined with [categories](/products/assetops/resources/categories) and [routing & dispatch](/products/assetops/resources/routing-dispatch) to route urgent work to the right teams. ## Related modules > [card] [Portfolio work orders](/products/assetops/portfolio/work-orders) > > Track open work and SLA status across all buildings. > [card] [Portfolio dashboard](/products/assetops/portfolio/dashboard) > > Monitor SLA met, breached, and compliance rate portfolio-wide. > [card] [Categories](/products/assetops/resources/categories) > > Classify work orders for routing alongside priority rules. # Portfolio schedules Source: https://docs.kodelabs.com/products/assetops/portfolio/schedules View, filter, export, and open schedules across all buildings in your AssetOps portfolio The **Schedules** module at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) shows recurring maintenance and inspection schedules across all buildings. Use it to confirm upcoming work, spot gaps, and align preventive programs portfolio-wide. ## Portfolio vs building schedules | Level | Scope | Typical use | | - | - | - | | Portfolio | All buildings | Compliance oversight, cross-site planning | | Building | One building | Create, edit, and run schedules for that site | Define and maintain schedule instances at the [building level](/products/assetops/schedules/schedules-overview). When you open a schedule from the portfolio list or calendar, AssetOps navigates to that schedule in the building context on the [schedule detail page](/products/assetops/schedules/schedules-overview#schedule-detail-page). *** ## Schedule list The default **list** view shows schedules from every building in the portfolio. ![Portfolio Schedules list view with search bar, list and calendar view toggles, Filters button, and schedules table](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-schedules-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=b865bc3c81ca502dc116f0d060a9d3b1) Portfolio schedules list with search, list and calendar toggles, and Filters | Column | Description | | - | - | | **Title** | Schedule name as a link, with schedule ID below (for example, `SCH-02239`). Select the title or the external-link icon beside it to open the schedule in the [building-level detail view](/products/assetops/schedules/schedules-overview#schedule-detail-page) for that schedule's building. | | **Work type** | **Preventive maintenance** or **Inspection** | | **Recurrence** | How often work is generated (for example, **Weekly**, **On demand**) | | **Status** | **Active** or inactive | | **Building** | Building where the schedule applies | | **Tasks** | Number of tasks and total estimated time | Use **Search schedules** to find records. Use the column control to show or hide fields. Pagination at the bottom shows how many schedules match your current filters. ### Export Open the vertical ellipsis menu in the schedule list header and select **Export** to download schedule data. ### Calendar view Select the **calendar** view toggle to see scheduled work across the portfolio on a monthly grid. ![Portfolio Schedules calendar view for May 2026 with schedule chips per day and Today navigation](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-schedules-calendar.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ce0c0c7da6f8d91f5021bd7ae0e24ddb) Portfolio calendar view shows maintenance and inspection schedules by day Use **Today**, month arrows, or the date picker to move between periods. Select a schedule chip or **+N more** link to open that schedule on the [schedule detail page](/products/assetops/schedules/schedules-overview#schedule-detail-page) in building context. ### Filters Select **Filters** to open the filter panel. ![Portfolio Schedules filters sidebar with Next Run Date, Building, Work Type, Inspection Type, Assignee, Team Assigned, and Frequency fields](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-schedules-filters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=dad50bb7cabf563902e85eb169f6e48c) Portfolio schedule filters include Building, work type, and next run date | Filter | Description | | - | - | | **Next run date** | Date range for upcoming runs | | **Building** | Limit results to one or more buildings | | **Region** | Geographic or organizational grouping | | **Work type** | Preventive maintenance or Inspection | | **Inspection type** | Inspection category for inspection schedules | | **Assignee** | User assigned to generated work orders | | **Team assigned** | Team assigned to generated work orders | | **Frequency** | Recurrence pattern (for example, monthly, weekly) | Select **Clear all** to reset filters. Building-level schedules document additional filters such as **Asset** on the [Building schedules](/products/assetops/schedules/schedules-overview#filters) page. > [!NOTE] > > Portfolio list, calendar, export, and filters mirror the building schedules experience. Bulk edit runs as a batch with per-item results, failure export, and a seven-day history. For **+ Create**, [spreadsheet import](/products/assetops/schedules/schedules-overview#import-schedules-from-a-spreadsheet), bulk edit fields, and the schedule wizard, see [Building schedules](/products/assetops/schedules/schedules-overview). *** ## Schedule types Building schedules support three schedule types. Each type defines how timing is applied when work is generated: * **Just once** — A single scheduled occurrence * **Recurrent** — Repeating intervals for preventive maintenance or inspections * **On demand** — Schedules triggered when needed *** ## Next steps > [card] [Schedule detail page](/products/assetops/schedules/schedules-overview#schedule-detail-page) > > View details, tasks, assets, attachments, and logs after you open a schedule from the portfolio list or calendar. > [card] [Building schedules](/products/assetops/schedules/schedules-overview) > > Create schedules, run bulk edit, and manage schedule status for one building. > [card] [Task templates](/products/assetops/resources/task-templates) > > Define reusable tasks assigned to scheduled work orders at the portfolio level. > [card] [Portfolio work orders](/products/assetops/portfolio/work-orders) > > Review work orders generated from schedules across all buildings. # Portfolio work orders Source: https://docs.kodelabs.com/products/assetops/portfolio/work-orders View, filter, and create work orders across all buildings in your AssetOps portfolio The **Work orders** module at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) lists work orders from every building in one place. Use it to monitor backlog, status, and assignments without switching buildings. ## Portfolio vs building work orders | Level | Scope | Typical use | | - | - | - | | Portfolio | All buildings | Oversight, reporting, cross-site triage | | Building | One building | Create, assign, and complete work on site | Most day-to-day work happens at the [building level](/products/assetops/work-orders/work-orders-overview). Portfolio **Work orders** focuses on visibility across sites. When you open a work order from the portfolio list, AssetOps navigates to that work order in the building context so you can view and manage it on the [work order detail page](/products/assetops/work-orders/work-orders-overview#work-order-detail-page). *** ## Work order list The portfolio work orders page shows status summary cards, search and filters, and a table of work orders across all buildings. ![Portfolio Work Orders page with status summary cards, Focus Mode toggle, search bar, and work orders table across buildings](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-work-orders-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=d17eaf90c149e6b1e45f59a2253a5ce3) Portfolio work orders list with status cards, Focus mode, search, and cross-building table ### Status summary cards Select a card to filter the table by that status. Counts reflect work orders portfolio-wide based on your current filters. | Status | Description | | - | - | | **Open** | Created but not yet started | | **In progress** | Currently being worked on | | **On hold** | Paused | | **For review** | Completed work awaiting review | | **Completed** | Finished work | | **Failed** | Work that did not complete successfully | | **Cancelled** | Cancelled work orders | | **Overdue** | Past due date and not completed | ### List actions * **Search** — Filter the table by text across visible fields * **Focus mode** — Toggle to show only urgent work (SLA breached, warnings, high priority). See [Focus mode](/products/assetops/work-orders/work-orders-overview#focus-mode) on the building work orders page for the same behavior at building level. * **Filters** — Filter by criteria such as **Asset type** and **Region** to narrow work by equipment or organizational grouping * **+ Create work order** — Start a new work order. See [Create a work order](#create-a-work-order). * Vertical ellipsis menu — Additional list actions ### Table columns | Column | Description | | - | - | | **Title** | Work order name as a link, with work order ID below (for example, `WO-10190`). Select the title or the external-link icon beside it to open the work order in the [building-level detail view](/products/assetops/work-orders/work-orders-overview#work-order-detail-page) for that work order's building. | | **Status** | Current lifecycle status (for example, **Open**, **In progress**) | | **Work type** | Program type (for example, preventive maintenance, corrective maintenance, inspection) | | **Asset** | Asset the work applies to | | **Located in** | Building area or location hierarchy for the work | | **Priority** | Priority level from [Priority & SLA](/products/assetops/portfolio/priority-sla) | | **Schedule** | Source schedule name and ID when the work order came from a schedule (for example, `SCH-02239`) | Use the column control and horizontal scroll to show additional fields such as tasks, SLA status, dates, assignee, and category. For the full column set, see [Work order fields](/products/assetops/reference/work-order-fields#list-columns). > [!NOTE] > > Portfolio list actions mirror the building list. Bulk edit runs as a batch with per-item results, failure export, and a seven-day history. For bulk edit fields, custom filters, and column details scoped to one building, see [Building work orders](/products/assetops/work-orders/work-orders-overview). *** ## Create a work order Select **+ Create work order** from the portfolio list to add work at a specific building. You must choose the **Building** field because the portfolio view spans all sites. ![Create Work Order form at portfolio level with Title, Work Type, required Building dropdown, Asset, Located In, Category, Issue Type, Priority, Description, Attachments, and assignment fields](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-work-orders-create.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=150d9acd215ab9327dae6190b81a2246) Portfolio create work order form with required Building field **1. Enter general details** Complete required fields. **Title** `Field` *required* Work order name. **Work type** `Dropdown` *required* Program type (for example, corrective maintenance). **Building** `Dropdown` *required* Target building for the work order. AssetOps scopes the work order to this building. **Asset** `Dropdown` Asset the work applies to. Options depend on the selected building. **Located in** `Dropdown` Building area for the work. **Category** `Dropdown` *required* [Category](/products/assetops/resources/categories) for the work. **Issue type** `Dropdown` *required* Issue type within the category. [Routing and dispatch](/products/assetops/resources/routing-dispatch) may prefill team and assignee when rules exist for the building. **Priority** `Dropdown` *required* Priority level for SLA tracking. **Description** `Field` Rich text description with formatting options. **Attachments** `Field` Upload supporting files. **2. Set assignment** Choose **Assign team**, **Assignee**, and **Vendor** as needed. Additional date and time fields match the [building create flow](/products/assetops/work-orders/work-orders-overview#create-a-work-order). **3. Save** Select **Save** to create the work order. Open it from the portfolio list or building list to reach the [work order detail page](/products/assetops/work-orders/work-orders-overview#work-order-detail-page). *** ## Related configuration Work orders use portfolio-wide [categories](/products/assetops/resources/categories), [vendors](/products/assetops/resources/vendors), and [task templates](/products/assetops/resources/task-templates). Configure those modules before teams create work at the building level. *** ## Next steps > [card] [Work order detail page](/products/assetops/work-orders/work-orders-overview#work-order-detail-page) > > View tasks, logged time, attachments, and follow-ups after you open a work order from the portfolio list. > [card] [Building work orders](/products/assetops/work-orders/work-orders-overview) > > Manage work orders, Focus mode, filters, and bulk edit for a single building. > [card] [Work order basics](/products/assetops/quickstart/work-orders) > > Learn how corrective, preventive, and inspection work orders differ in AssetOps. > [card] [Priority & SLA](/products/assetops/portfolio/priority-sla) > > Define SLA targets that drive status and Focus mode on work order lists. # Understanding Assets Source: https://docs.kodelabs.com/products/assetops/quickstart/assets Understand assets in AssetOps and how they are organized An asset represents a physical device or piece of equipment located within a building. Assets require monitoring, maintenance, or operational oversight. Assets are managed at the building level, where authorized users can view, add, and manage the assets associated with each building in the portfolio. ## Asset Categories & Types In AssetOps, every asset is required to have both a **category** and a **type**. Categories define the general function or role of an asset within a building, while types provide a more specific classification for that asset. This structure ensures that assets are consistently categorized and clearly defined. ### Asset Categories AssetOps includes three predefined categories, allowing you to organize assets during asset addition based on their function and role within a building. * The **Equipment** category represents mechanical, electrical, or operational devices such as HVAC units, generators, elevators, and other systems that require regular maintenance and servicing. * The **Architectural** category represents structural and building elements such as walls, roofs, doors, windows, and flooring that are part of the building's physical structure. * The **Furniture** category represents movable items such as desks, chairs, cabinets, and other furnishings that support the use and functionality of the space. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR subgraph s1["Buildings"] C1["Building 1"] C2["Building 2"] C3["Building 3"] end subgraph s2["Asset Categories"] Assets1["Equipment (Category)"] Assets2["Architectural (Category)"] Assets3["Furniture (Category)"] end C2 --- Z["Building Assets"] Z -- category ----- Assets1 & Assets2 & Assets3 C1:::Sky C2:::Sky C3:::Sky Assets1:::Rose Assets2:::Rose Assets3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none ``` ### Asset Types An asset type represents a more specific classification of an asset, and is always defined within the context of its corresponding asset category. AssetOps allows you to define any asset type you want when adding new assets. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR subgraph s1["Buildings"] C1["Building 1"] C2["Building 2"] C3["Building 3"] end subgraph s2["Asset Categories"] Assets1["Furniture (Category)"] Assets2["Equipment (Category)"] Assets3["Architectural (Category)"] end subgraph s3["Asset Types"] Type1["Desk (Type)"] Type2["Chair (Type)"] end subgraph s4["Asset Types1"] Type5["Door (Type)"] Type6["Window (Type)"] end subgraph s5["Asset Types"] Type3["HVAC (Type)"] Type4["Pump (Type)"] end C2 --- Z["Building Assets"] Z -- category --- Assets1 & Assets2 & Assets3 Assets1 ---|includes| Type1 & Type2 Assets2 ---|includes| Type3 & Type4 Assets3 ---|includes| Type5 & Type6 C1:::Sky C2:::Sky C3:::Sky Assets1:::Rose Assets2:::Rose Assets3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00,fill:none linkStyle 7 stroke:#FF6D00 linkStyle 8 stroke:#FF6D00,fill:none linkStyle 9 stroke:#FF6D00,fill:none ``` # Completion policies Source: https://docs.kodelabs.com/products/assetops/quickstart/completion-policies Configure building-level completion policies for work orders in AssetOps **Completion policies** define requirements that must be met before a work order can move to **For review** or **Complete**. Configure them at the [building level](/products/assetops/quickstart/usage-workflow#building-level) when site rules differ from portfolio defaults. > [!NOTE] > > Portfolio defaults are configured under [Settings > Completion policies](/products/assetops/quickstart/settings-completion-policies). Use this page to override policies for the selected building. Open a building from [Buildings](/products/assetops/resources/buildings), then select **Completion policies** in the building sidebar. ## Require actions Set completion policies for the building based on your operational preferences. ![Building Completion Policies page with Require actions rules, Override Default toggle, and expanded Time logging before completion work order types](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-completion-policies.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=5528cfd6fa772b0e9672c687c1bebca6) Completion policies list rules with toggles, work order type scope, and Override Default ### Override default Use **Override default** in the top right to enable building-specific policies instead of portfolio defaults from [Settings](/products/assetops/quickstart/settings-completion-policies). When override is off, the building uses portfolio rules. ### Policy options Toggle each policy on or off. Expand a rule to choose which work order types it applies to, then select **Edit** to save. **All tasks marked Done or N/A** `Toggle` Ensure all tasks are completed or marked not applicable before the work order can complete. Applies to preventive maintenance and inspection work orders. **Time logging before completion** `Toggle` Require logged work hours before completion. Expand the rule to select work order types such as preventive maintenance, corrective maintenance, or service request. **Follow-up work order when action needed** `Toggle` Require a follow-up work order when any task is marked **Action needed** before the work order moves to **For review**. **Note when task is non-compliant** `Toggle` Require an explanation note when a task is marked non-compliant. **Attachment when task is non-compliant** `Toggle` Require supporting documentation when a task is marked non-compliant. **Note when task is N/A** `Toggle` Require an explanation note when a task is marked not applicable. ## Choose work order types When you expand a policy, select **Choose work order types** to limit the rule to specific programs: * **Preventive maintenance** * **Inspection** * **Corrective maintenance** * **Compliance maintenance** * **Service request** ## Related modules > [card] [Portfolio completion policies](/products/assetops/quickstart/settings-completion-policies) > > View portfolio default completion policies in Settings. > [card] [Status transitions](/products/assetops/quickstart/settings-status-transitions) > > Control status changes that trigger completion policy checks. # Notification settings Source: https://docs.kodelabs.com/products/assetops/quickstart/notifications Configure notification settings for work order events in AssetOps Notification settings control how AssetOps informs users about work order activity. Open **Settings** > **Notifications** at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level). You choose which events generate alerts, how they are delivered (push or email), and who receives them. ![AssetOps Notifications settings with Work Order Created expanded showing delivery methods Push and Email and recipient checkboxes](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-notifications.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=f2e29c38484398dc2990009943643270) The Notifications settings page lists work order events with enable toggles and expandable configuration ## Configuration Toggle on and configure each notification event. Expand a rule to set delivery methods and recipients, then select **Edit** to save. **Work Order Created** `Toggle & Configure` Send a notification when a new work order is created **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Assigned** `Toggle & Configure` Send a notification when a new work order has been assigned **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Updated** `Toggle & Configure` Send a notification when a work order has been updated **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Status Updated** `Toggle & Configure` Send a notification when the status of a work order has been updated **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Deleted** `Toggle & Configure` Send a notification when a work order has been deleted **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Due Soon** `Toggle & Configure` Send a notification when a work order is due soon for completion **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Days Before Due Date** `Number` Specifies the number of days before the due date to send the notification **Work Order Still Overdue** `Toggle & Configure` Send a notification when an overdue work order remains unresolved **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Days Past Due Date** `Number` Specifies the number of days that have passed since the work order's due date ## Next steps > [card] [Notification events](/products/assetops/reference/notification-events) > > Look up every event, delivery method, and recipient type in one table. > [card] [Portfolio settings](/products/assetops/quickstart/settings) > > Return to the settings hub for policies, permissions, and status transitions. # What is AssetOps? Source: https://docs.kodelabs.com/products/assetops/quickstart/overview Introduction to AssetOps for asset and maintenance operations [AssetOps overview](https://www.youtube.com/embed/a6dmBPk-UFs?si=oWP-owR5_V-GjVbc) AssetOps is the KODE product for asset and maintenance operations, functioning as a dedicated CMMS (A Computerized Maintenance Management System (CMMS) is software that centralizes maintenance information to help organizations automate, track, and optimize asset management and workflows.) in the KODE OS ecosystem. AssetOps works across your entire portfolio, providing a single platform to run operations consistently and maintain oversight over all assets and maintenance activities. It enables management of physical assets including equipment, systems, and locations, and allows you to track and organize all associated work such as maintenance, repairs, inspections, and other operational tasks. ## How documentation is organized AssetOps documentation follows the product navigation: * **Portfolio level** — Cross-building oversight, shared resources, and portfolio configuration * **Building level** — Day-to-day operations after you select a building See [Operation levels](/products/assetops/quickstart/usage-workflow) for how portfolio and building views connect. ## Portfolio level modules > [card] [Dashboard](/products/assetops/portfolio/dashboard) > > Monitor maintenance performance across the portfolio. > [card] [Buildings](/products/assetops/resources/buildings) > > View buildings and open building-level operations. > [card] [Work orders](/products/assetops/portfolio/work-orders) > > Track work orders across all buildings. > [card] [Schedules](/products/assetops/portfolio/schedules) > > Monitor recurring maintenance portfolio-wide. > [card] [Vendors](/products/assetops/resources/vendors) > > Manage external service providers shared across buildings. > [card] [Categories](/products/assetops/resources/categories) > > Define categories and issue types for classifying work. > [card] [Tasks](/products/assetops/resources/task-templates) > > Create reusable task templates for scheduled work. > [card] [Priority & SLA](/products/assetops/portfolio/priority-sla) > > Configure priority levels and SLA targets. > [card] [Settings](/products/assetops/quickstart/settings) > > Configure notifications, completion policies, field permissions, and status transitions. ## Building level modules > [card] [Dashboard](/products/assetops/building/dashboard) > > Monitor activity for the selected building. > [card] [Work orders](/products/assetops/work-orders/work-orders-overview) > > Create and manage corrective maintenance work orders. > [card] [Schedules](/products/assetops/schedules/schedules-overview) > > Plan preventive maintenance and inspections. > [card] [Assets](/products/assetops/assets/assets) > > View and manage building assets. > [card] [Asset discovery](/products/assetops/assets/asset-discovery) > > Discover and onboard assets for a building. > [card] [Teams](/products/assetops/resources/teams) > > Organize assignees for building work orders. > [card] [Routing & dispatch](/products/assetops/resources/routing-dispatch) > > Route work to the right teams automatically. > [card] [Completion policies](/products/assetops/quickstart/completion-policies) > > Set requirements before work orders can close. ## Concepts > [card] [Work order basics](/products/assetops/quickstart/work-orders) > > Understand corrective, preventive, and inspection work orders. > [card] [Assets overview](/products/assetops/quickstart/assets) > > Learn how assets are organized by category and type. # Portfolio settings Source: https://docs.kodelabs.com/products/assetops/quickstart/settings Portfolio-level settings for notifications, completion policies, field permissions, and status transitions in AssetOps Portfolio **Settings** in AssetOps control how work orders behave across every building in your portfolio. Open **Settings** from the portfolio sidebar to configure alerts, completion rules, field access, and status changes from one place. Settings apply at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level). Some rules can be overridden at the [building level](/products/assetops/quickstart/usage-workflow#building-level), such as [completion policies](/products/assetops/quickstart/completion-policies) for individual sites. ## Settings areas Use the Settings secondary navigation to open each area: | Area | Purpose | | - | - | | [Notifications](/products/assetops/quickstart/notifications) | Alerts for work order events | | [Completion policies](/products/assetops/quickstart/settings-completion-policies) | Requirements before work orders close | | [Field permissions](/products/assetops/quickstart/settings-field-permissions) | Read-only and locked fields by type, status, or time | | [Status transitions](/products/assetops/quickstart/settings-status-transitions) | Who can change work order status | > [card] [Notifications](/products/assetops/quickstart/notifications) > > Configure push and email alerts for work order activity. > [card] [Completion policies](/products/assetops/quickstart/settings-completion-policies) > > Set rules that must be met before work orders complete or go for review. > [card] [Field permissions](/products/assetops/quickstart/settings-field-permissions) > > Restrict field edits by work order type, status, or due date. > [card] [Status transitions](/products/assetops/quickstart/settings-status-transitions) > > Control which roles can perform status changes. ## Building-level overrides [Completion policies](/products/assetops/quickstart/completion-policies) can also be configured per building when site-specific rules differ from portfolio defaults. # Completion policies settings Source: https://docs.kodelabs.com/products/assetops/quickstart/settings-completion-policies Configure portfolio completion policies for work orders in AssetOps **Completion policies** define requirements that must be met before a work order can move to **For review** or **Complete**. Configure them under **Settings** at the portfolio level so rules apply consistently across buildings. ![AssetOps Completion Policies settings with Require actions rules, toggles, work order type checkboxes, and Edit buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-completion-policies.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ca8db02193da31a2069286908bd6edc8) Completion policies list rules with toggles and work order type scope ## Require actions The **Require actions** section lists conditions you can enable for closing work orders. Select a rule to expand it, choose which work order types it applies to, and select **Edit** to save changes. ### Available policies **All tasks marked Done or N/A** `Toggle` Ensure all tasks are completed or marked not applicable before the work order can complete. Apply to preventive maintenance and inspection work orders. **Time logging before completion** `Toggle` Require logged work hours before completion. Can apply to preventive maintenance, inspection, corrective maintenance, and service request types. **Follow-up work order when action needed** `Toggle` Require a follow-up work order when any task is marked **Action needed** before the work order moves to **For review**. **Note when task is non-compliant** `Toggle` Require an explanation note when a task is marked non-compliant. **Attachment when task is non-compliant** `Toggle` Require supporting documentation when a task is marked non-compliant. **Note when task is N/A** `Toggle` Require an explanation note when a task is marked not applicable. ## Choose work order types Each policy includes **Choose work order types** checkboxes: * **Preventive maintenance** * **Inspection** * **Corrective maintenance** * **Compliance maintenance** * **Service request** Enable only the types that should follow the rule. ## Building-level overrides Sites can override portfolio policies on the building [completion policies](/products/assetops/quickstart/completion-policies) page when local rules differ. For a consolidated view of every policy and its scope, see [Completion policy options](/products/assetops/reference/completion-policy-options). # Field permissions settings Source: https://docs.kodelabs.com/products/assetops/quickstart/settings-field-permissions Configure field permissions by work order type, status, and time in AssetOps **Field permissions** control which work order fields users can edit under specific conditions. Configure restrictions under **Settings** at the portfolio level using three tabs: **Restrict by type**, **Restrict by status**, and **Restrict by time**. ## Restrict by type Restrict specific fields to read-only for selected work order types and roles. ![AssetOps Field Permissions Restrict by Type tab with field toggles for Title, dates, Status, and Category with expanded configuration](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-field-permissions-type.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=71ef91ea76ec58e570151d2ea2abfd66) Restrict individual fields by work order type and role For each field, such as **Title**, **Start date & time**, **Due date & time**, **Status**, or **Category**: 1. Enable the toggle to activate the restriction. 2. Expand the rule and select **Choose work order types**. 3. Choose **Only these roles** or **Except these roles**, then select roles in the dropdown. 4. Select **Edit** to save. ## Restrict by status Lock fields when a work order reaches specific statuses. ![AssetOps Field Permissions Restrict by Status tab with Fields at For Review expanded showing work order types, exclude fields, roles, and exclude for actions](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-field-permissions-status.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=bd659966d4a802ece91874af6e6a4afb) Lock fields at For Review, Complete, Cancelled, or Failed status Status-based rules include: | Rule | Description | | - | - | | **Fields at For review** | Lock fields while the work order awaits manager review | | **Fields at Complete** | Lock fields in complete status; attachments and comments can remain allowed | | **Fields at Cancelled** | Lock fields in cancelled status (terminal) | | **Fields at Failed** | Lock fields in failed status | Expanded configuration options: * **Choose work order types** — Scope the rule by program * **Exclude fields** — Keep specific fields editable (for example, **Status**) * **Apply to** — **Only these roles** or **Except these roles** * **Exclude for actions** — Allow **Add comment** or **Add attachment** while fields are locked ## Restrict by time Lock the entire work order record when a date condition is met. ![AssetOps Field Permissions Restrict by Time tab with Lock record after due date passes rule expanded](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-field-permissions-time.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=21e35c28964221f2f15df5a839fa9d91) Lock records after the due date or after due date plus grace period Time-based rules include: | Rule | Description | | - | - | | **Lock record after due date passes** | Lock all fields when the due date has passed | | **Lock record after due date + grace period passes** | Lock all fields after the due date plus grace period | Each rule supports **Choose work order types**, **Exclude fields**, role scope, and **Exclude for actions** options similar to status-based rules. # Status transitions settings Source: https://docs.kodelabs.com/products/assetops/quickstart/settings-status-transitions Configure which roles can perform work order status transitions in AssetOps **Status transitions** define which roles can move work orders between statuses. Configure rules under **Settings** at the portfolio level. When a transition is disabled, no role can perform that change. ![AssetOps Status Transitions settings with Completion rule expanded showing work order types and role scope](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-settings-status-transitions.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a01acc56c0a400773a15d21e59dd4e08) Restrict status transitions by work order type and role ## Restrict transitions Each rule includes a toggle, description, and expandable configuration. Select **Edit** to choose work order types and roles. ### Transition rules | Rule | Description | | - | - | | **Completion** | Restrict completing a work order from incomplete statuses (open, in progress, on hold) except from **For review** | | **In progress → For review** | Restrict moving from **In progress** to **For review**; completion policies are evaluated at this step | | **For review → In progress** | Restrict sending a work order back from **For review** to **In progress** | | **For review → Complete** | Restrict **For review** to **Complete**; second step of two-step verification | | **Complete → Open (reopen)** | Restrict reopening a completed work order to **Open** | | **Cancellation** | Restrict cancelling from incomplete statuses (open, in progress, for review) | ### Configure a rule When you expand a rule: 1. Enable the toggle to activate the restriction. 2. Under **Choose work order types**, select programs such as inspection, corrective maintenance, or service request. 3. Under **Apply to**, choose **Only these roles** or **Except these roles**. 4. Select roles in the dropdown. 5. Select **Edit** to save. > [!NOTE] > > Completion policies run when work orders move to **For review** or **Complete**. Align [completion policies](/products/assetops/quickstart/settings-completion-policies) with status transition rules. # Operations Levels in AssetOps Source: https://docs.kodelabs.com/products/assetops/quickstart/usage-workflow Seamless navigation between portfolio and building levels AssetOps provides flexibility in how you manage and administer maintenance operations, supporting both `portfolio-level` oversight and `building-level` execution. This dual-level approach allows you to coordinate strategies across your entire portfolio while addressing the specific needs of individual buildings. Actions and configurations applied at the portfolio level determine the availability or configuration of resources at the building level. Subsequently, actions performed at the building level are reflected at the portfolio level, ensuring centralized visibility and consistent management across all sites. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart TD subgraph s1["Operation Levels"] A1["Portfolio-Level"] A2["Building-Level"] end subgraph s2["Buildings"] B1["Building 1"] B2["Building 2"] B3["Building 3"] end A["AssetOps"] -- access --- A1 A1 -- access --- A2 A2 -- access --- B1 & B2 & B3 s2 -- perform --- P["Building-Level Ops"] P -- reflect back --- A1 A1 ---|perform| A3 A3 -- determine --- P A3["Portfolio-Level Ops"] A1:::Sky A2:::Sky B1:::Rose B2:::Rose B3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#00C853,fill:none linkStyle 7 stroke:#FF6D00,fill:none linkStyle 8 stroke:#FF6D00 ``` ## Portfolio-Level The portfolio level in AssetOps provides centralized oversight of all buildings for a client, serving as the main management hub. From this level, you can initially manage and monitor the entire portfolio, while also using it as the entry point to access and manage individual buildings. In addition, the portfolio level allows configuration of portfolio-wide settings and the management of shared resources, such as vendors, categories, or task templates, ensuring consistent operations and standardized processes across all sites. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio Buildings"] N1["Building 1"] N2["Building 2"] N3["Building 3"] end subgraph s2["Portfolio-Level Ops"] B1["Analytics"] B2["Buildings"] B3["Work Orders"] B8["Schedules"] B4["Vendors"] B5["Categories"] B9["Tasks"] B10["Priority & SLA"] B6["Settings"] end A["AssetOps"] -..- B["Portfolio-Level"] B ---- B1 & B2 & B3 & B8 & B4 & B5 & B9 & B10 & B6 B2 -- "access building-level" ---- N1 & N2 & N3 N1:::Sky N2:::Sky N3:::Sky classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#00C853,fill:none linkStyle 6 stroke:#00C853,fill:none linkStyle 7 stroke:#00C853,fill:none linkStyle 8 stroke:#00C853 linkStyle 9 stroke:#FF6D00,fill:none linkStyle 10 stroke:#FF6D00,fill:none linkStyle 11 stroke:#FF6D00,fill:none ``` ## Building-Level At the building level, AssetOps allows you to manage operations for a specific building in detail. You can add and manage assets, create and track work orders, and apply configuration policies defined at the portfolio level. Building-level operations also include allocating work through routing and dispatch, managing teams, and overseeing day-to-day maintenance activities. All actions performed at the building level flow back to the portfolio level, ensuring complete visibility and consistent oversight across the entire portfolio. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio Buildings"] N1["Building 1"] N2["Building 2"] N3["Building 3"] end subgraph s2["Building-Level Ops"] A["Analytics"] B["Work Orders"] C["Schedules"] D["Assets"] D1["Asset Discovery"] E["Teams"] F["Routing & Dispatch"] H["Completion Policies"] end N2 -- "building-specific" ----- A & B & C & D & D1 & E & F & H O["AssetOps"] -..- O1 ---|access| N2 O1[Building-Level] N1:::Sky N2:::Sky N3:::Sky classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C linkStyle 0 stroke:#FF6D00,fill:none linkStyle 1 stroke:#FF6D00,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00 linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00,fill:none ``` ## Role-Based Access Implications Your [role in KODE OS](/products/launchpad/client-organizations/apps#kode-os-roles) determines whether AssetOps is available to you and, if so, defines your specific permissions within the product. Understanding role-based permissions is essential, as they govern what actions you can perform, which assets and buildings you can access, and how you interact with AssetOps overall. Creating distinct KODE OS roles for AssetOps can be highly beneficial, allowing you to allocate appropriate levels of access to different users based on their responsibilities. This approach ensures that users have the tools and visibility they need to perform their tasks efficiently, while control, security, and consistent operational standards are preserved across the organization. # Understanding Work Orders Source: https://docs.kodelabs.com/products/assetops/quickstart/work-orders Understand work orders in AssetOps and how they are administered A work order is a single, trackable unit of work, such as a routine maintenance task, ad hoc repair, or inspection. It represents an individual task that is created, assigned, and completed as part of a maintenance activity. Work orders in AssetOps can be created as one-time or recurring tasks, depending on the maintenance activity you need to complete. They can be assigned to internal staff or external vendors, with clearly defined due dates and estimated effort. ## Maintenance Types In AssetOps, work orders are created around predefined maintenance types that ultimately determine the type of work order you create based on the maintenance activity you need to complete. These predefined maintenance types include **corrective maintenance**, **preventive maintenance**, and **inspections**. These predefined maintenance types allow for both **reactive** maintenance, which addresses issues or failures as they occur, and **proactive** maintenance, which is planned in advance to prevent problems and maintain asset health. * The **Corrective Maintenance** type refers to maintenance tasks performed on assets that are faulty or not functioning properly. It focuses on restoring asset functionality, minimizing downtime, and returning operations to normal as quickly as possible. * The **Preventive Maintenance** type refers to maintenance tasks carried out routinely on assets to prevent failures and keep them operating efficiently. It focuses on reducing the likelihood of failures and maintaining asset health through routine checks and servicing. * The **Inspection** type refers to maintenance tasks aimed at checking and assessing conditions to identify issues or ensure compliance with standards. It focuses on assessing asset condition and enabling early detection of potential issues. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Type Characteristics"] B1["Reactive"] B2["Fix after failure"] end subgraph s2["Type Characteristics"] C1["Proactive"] C2["Scheduled upkeep"] end subgraph s3["Type Characteristics"] E1["Proactive"] E2["Condition assessment"] end A["Maintenance Types"] --->|type| B["Corrective Maintenance"] & C["Preventive Maintenance"] & E["Inspection"] B -->|approach| B1 B -->|purpose| B2 C -->|approach| C1 C -->|purpose| C2 E -->|approach| E1 E -->|purpose| E2 B1:::Rose C1:::Class_01 E1:::Class_01 B:::Sky C:::Sky E:::Sky classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Class_01 fill:#B0E4CC, color:#285A48, stroke:#285A48 ``` ## Work Order Types AssetOps supports two work order types, **generic** and **scheduled**, and the one you use depends on the maintenance activity you need to complete. Each type is tied to at least one of the predefined [maintenance types](/products/assetops/quickstart/work-orders#maintenance-types) in AssetOps. ### Generic Work Orders In AssetOps, generic work orders are used to create one-time tasks for maintenance activities, primarily focusing on resolving faults and restoring normal asset operation. Generic work orders support the Corrective Maintenance (Applied to specific assets or areas to fix issues and restore functionality.) type, enabling teams to swiftly address area related issues or faulty assets and manage unplanned maintenance. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Work Order Types"] B2["Corrective Maintenance"] end subgraph s3["Assets"] I["Asset 1"] I1["Asset 2"] I2["Asset 3"] end subgraph s4["Areas"] AR1["Area 1"] AR2["Area 2"] AR3["Area 3"] end A["AssetOps"] --- B["Work Orders"] B -- Work Order Type --- B2 B2 -- create work order for --- I & I1 & I2 & AR1 & AR2 & AR3 B2:::Sky I:::Rose I1:::Rose I2:::Rose AR1:::Peach AR2:::Peach AR3:::Peach classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Peach stroke-width:1px, stroke-dasharray:none, stroke:#FBB35A, fill:#FFEFDB, color:#8F632D ``` ### Scheduled Work Orders In AssetOps, schedules are used to generate recurring work orders and ensure that routine maintenance activities are completed consistently and on time. Scheduled work orders support two maintenance types, Preventive Maintenance (Applied to specific assets to maintain performance and prevent failures.) and Inspections (Can cover assets, areas, or general miscellaneous observations to check condition and ensure compliance.), enabling teams to proactively manage recurring maintenance jobs and keep assets in optimal condition. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Work Order Types"] B1["Preventive Maintenance"] B2["Inspection"] end subgraph s2["Assets"] A1["Asset 1"] A2["Asset 2"] A3["Asset 3"] end subgraph s3["Inspection Types"] I["Assets"] I1["Areas"] I2["General"] end A["AssetOps"] --- B["Schedules"] B -- Work Order Type --- B1 & B2 B1 -- scheduled maintenance --- A1 & A2 & A3 B2 -- scheduled inspection --- I & I1 & I2 B1:::Sky B2:::Sky A1:::Rose A2:::Rose A3:::Rose I:::Rose I1:::Peach I2:::Class_02 classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Ash stroke-width:1px, stroke-dasharray:none, stroke:#999999, fill:#EEEEEE, color:#000000 classDef Peach stroke-width:1px, stroke-dasharray:none, stroke:#FBB35A, fill:#FFEFDB, color:#8F632D classDef Aqua stroke-width:1px, stroke-dasharray:none, stroke:#46EDC8, fill:#DEFFF8, color:#378E7A classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Class_02 fill:#B0E4CC, color:#285A48, stroke:#285A48 ``` # Asset fields and columns Source: https://docs.kodelabs.com/products/assetops/reference/asset-fields Reference for AssetOps asset list columns, bulk-editable fields, detail page fields, and technical specifications Look up the fields that describe an asset in AssetOps. To view or edit assets, see [Assets](/products/assetops/assets/assets). For how categories and types are structured, see [Asset basics](/products/assetops/quickstart/assets). ## List columns These columns appear on the building [asset list](/products/assetops/assets/assets#asset-list). | Column | Description | | - | - | | Name | The asset name | | Category | Equipment, Architectural, or Furniture | | Type | The specific asset type (for example, AHU, VAV, Boiler) | | Model number | Manufacturer model number | | Area | The building area where the asset is located | | Status | `Active` or `Out of service`. The list shows only these statuses. | ## Bulk-editable fields Bulk edit supports the fields below. Dropdown fields use **Select an option**. Text fields use **Enter**. Date fields use the date picker (`mm/dd/yyyy`). **Classification and location** **Category** `Dropdown` Asset category (for example, Equipment). **Type** `Dropdown` Asset type within the category (for example, VAV, AHU). **Area** `Dropdown` Building area where the asset is located. **Location** `Field` Specific location description within the area. **Identification and network** **IP address** `Field` Network IP address for the asset. **Model number** `Field` Manufacturer model number. **Dates** **Installation date** `Date` Date the asset was installed. **Warranty date** `Date` Warranty expiration date. **Commission date** `Date` Date the asset was commissioned. **Turnover date** `Date` Date the asset was turned over to operations. **Asset tag** `Field` Unique identifier tag for the asset. **Physical and lifecycle** **Weight** `Field` Asset weight. Choose units: **lb** or **Pounds**. **Life expectancy** `Field` Expected useful life. Choose units: **day** or **Days**. **Status** `Dropdown` Operational status (for example, Active, Out of Service, Decommissioned). **Technical specifications** **Belt size** `Field` Belt dimensions. Units: **in**. **Filter size** `Field` Filter dimensions. Units: **in**. **Tonnage** `Field` Cooling capacity in tons. **Power** `Field` Power rating. Choose units: **hp**. **Amps** `Field` Electrical current draw. **Volts** `Field` Operating voltage. **RPMs** `Field` Rotational speed. **Financial** **Initial cost** `Field` Original purchase cost. Currency: **USD** or **USD (\$)**. **Repair cost** `Field` Cost of last repair. Currency: **USD** or **USD (\$)**. **Replacement cost** `Field` Estimated replacement cost. Currency: **USD** or **USD (\$)**. **Software and vendors** **Firmware version** `Field` Device firmware version. **OS version** `Field` Operating system version. **Manufactured by** `Field` Manufacturer name. **Commissioned by** `Field` Vendor that commissioned the asset. **Installed by** `Field` Vendor that installed the asset. **Serviced by** `Field` Vendor that services the asset. > [!NOTE] > > Bulk edit does not include every field on the asset detail page. Fields such as **Serial number** and **MAC address** are available when you edit a single asset. ## Detail page fields The **General information** section of the asset detail page lists these attributes. | Field | Description | | - | - | | Name | Asset name. An external-link icon opens the linked Cloud BMS device when applicable. | | Category | Equipment, Architectural, or Furniture | | Type | Specific asset type within the category (for example, VAV, AHU) | | Location | Specific location description within the building | | IP address | Network IP address | | MAC address | Network MAC address | | Model number | Manufacturer model number | | Serial number | Manufacturer serial number | | Installation date | Date the asset was installed | | Warranty date | Warranty expiration date | | Commission date | Date the asset was commissioned | | Turnover date | Date turned over to operations | | Asset tag | Unique identifier tag | | Weight | Asset weight (for example, `100lb`) | | Status | Active, Out of Service, or Decommissioned | | Life expectancy | Expected useful life (for example, `100d`) | | Manufactured by | Manufacturer name | | Commissioned by | Vendor that commissioned the asset | | Installed by | Vendor that installed the asset | | Serviced by | Vendor that services the asset | | Initial cost | Original purchase cost | | Repair cost | Cost of last repair | | Replacement cost | Estimated replacement cost | | Firmware version | Device firmware version | | OS version | Operating system version | ## Technical specifications **Technical specifications** lists HVAC and electrical ratings separate from general information. | Field | Example format | | - | - | | Belt size | `12 in` | | Filter size | `12 in` | | Tonnage | `122 TR` | | Power | `1222 hp` | | Amps | `123 A` | | Volts | `123 V` | | RPMs | `1234 RPM` | ## Detail page tabs | Tab | Purpose | | - | - | | **Details** | Asset fields, technical specs, and related schedules and work orders | | **Sources** | Data sources linked to the asset | | **Attachments** | Files attached to the asset record | ## Source record columns The **Sources** tab lists each [data source](/products/assetops/assets/asset-discovery) record linked to the asset. | Column | Description | | - | - | | Name | Display name for the linked source record. Select the name to open source details. | | Identifier | Unique ID for the record in the data source (for example, `h:c4c5`). | | Data source | Connector or import source name (for example, `jace`). | ## Source detail fields Select a source record name to open a read-only modal. The **General** tab shows these values. | Field | Description | | - | - | | Identifier | Source-system ID (for example, `h:c4c5`) | | Name | Record name in the source (for example, `VAV_304`) | | MAC address | MAC address from the source | | IP address | IP address from the source | | Manufacturer | Manufacturer reported by the source | | Model | Model reported by the source | | Firmware version | Firmware version from the source | | OS version | Operating system version from the source | Empty values display as a dash. ## Related reference > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Fields on work orders that reference assets. > [card] [Schedule fields](/products/assetops/reference/schedule-fields) > > Fields that determine which assets a schedule covers. # Completion policy options Source: https://docs.kodelabs.com/products/assetops/reference/completion-policy-options Reference for AssetOps completion policy rules and the work order types each policy can apply to Look up the rules that must be satisfied before a work order can move to **For review** or **Complete**. To configure these rules, see [Completion policies settings](/products/assetops/quickstart/settings-completion-policies) at the portfolio level, or [Completion policies](/products/assetops/quickstart/completion-policies) for building overrides. ## Available policies **All tasks marked Done or N/A** `Toggle` Ensure all tasks are completed or marked not applicable before the work order can complete. Apply to preventive maintenance and inspection work orders. **Time logging before completion** `Toggle` Require logged work hours before completion. Can apply to preventive maintenance, inspection, corrective maintenance, and service request types. **Follow-up work order when action needed** `Toggle` Require a follow-up work order when any task is marked **Action needed** before the work order moves to **For review**. **Note when task is non-compliant** `Toggle` Require an explanation note when a task is marked non-compliant. **Attachment when task is non-compliant** `Toggle` Require supporting documentation when a task is marked non-compliant. **Note when task is N/A** `Toggle` Require an explanation note when a task is marked not applicable. ## Work order types Each policy includes **Choose work order types** checkboxes. Enable only the types that should follow the rule. * **Preventive maintenance** * **Inspection** * **Corrective maintenance** * **Compliance maintenance** * **Service request** ## Scope | Level | Behavior | | - | - | | Portfolio | Sets the default policy applied across all buildings | | Building | Overrides the portfolio default when local rules differ | ## Related reference > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Task completion fields these policies can require. > [card] [Notification events](/products/assetops/reference/notification-events) > > Alerts for work orders that stall before completion. # Notification events Source: https://docs.kodelabs.com/products/assetops/reference/notification-events Reference for AssetOps work order notification events, delivery methods, and recipient options Look up every work order event AssetOps can notify on, along with its delivery methods and recipient options. To configure notifications, see [Notification settings](/products/assetops/quickstart/notifications). ## Delivery methods | Method | Description | | - | - | | **Push** | Sends a push notification, including to the [mobile app](/products/mobile-app/glossary) | | **Email** | Sends an email to the selected recipients | ## Recipient types | Recipient | Who receives the notification | | - | - | | **Current assignee** | User currently assigned to the work order | | **Lead member** | Lead member responsible for the work order | | **Team assigned** | All members of the assigned [team](/products/assetops/resources/teams) | | **User role recipients** | Every user with a selected KODE OS role | | **Custom recipients** | Named users, regardless of role | ## Events Each event has its own delivery methods and recipients. Two events add a day threshold. **Work Order Created** `Toggle & Configure` Send a notification when a new work order is created **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Assigned** `Toggle & Configure` Send a notification when a new work order has been assigned **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Updated** `Toggle & Configure` Send a notification when a work order has been updated **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Status Updated** `Toggle & Configure` Send a notification when the status of a work order has been updated **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Deleted** `Toggle & Configure` Send a notification when a work order has been deleted **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Work Order Due Soon** `Toggle & Configure` Send a notification when a work order is due soon for completion **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Days Before Due Date** `Number` Specifies the number of days before the due date to send the notification **Work Order Still Overdue** `Toggle & Configure` Send a notification when an overdue work order remains unresolved **Configuration Options** **Push** `Checkbox` Send a push notification to selected recipients **Email** `Checkbox` Send an email notification to selected recipients **Current Assignee** `Checkbox` Send notifications to the current assignee of the work order **Lead Member** `Checkbox` Send notifications to the lead member responsible for the work order **Team Assigned** `Checkbox` Send notifications to all members assigned to the work order **User Role Recipients** `Dropdown Selector` Send notifications to users of a specific KODE OS role **Custom Recipients** `Dropdown Selector` Send notifications to selected users, regardless of role **Days Past Due Date** `Number` Specifies the number of days that have passed since the work order's due date ## Events with thresholds | Event | Threshold field | Effect | | - | - | - | | **Work order due soon** | **Days before due date** | Sends the notification this many days ahead of the due date | | **Work order still overdue** | **Days past due date** | Sends the notification this many days after the due date passes | ## Related reference > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Statuses and fields the notification events respond to. > [card] [Completion policy options](/products/assetops/reference/completion-policy-options) > > Rules that control when a work order can close. # Schedule fields and options Source: https://docs.kodelabs.com/products/assetops/reference/schedule-fields Reference for AssetOps schedule list columns, filter criteria, creation wizard fields, and bulk edit fields Look up the values that define a schedule in AssetOps. To create or manage schedules, see [Building schedules](/products/assetops/schedules/schedules-overview). ## List columns These columns appear on the building and [portfolio](/products/assetops/portfolio/schedules) schedule lists. | Column | Description | | - | - | | **Title** | Schedule name as a link, with schedule ID below (for example, `SCH-02235`). An external-link icon opens the linked Cloud BMS device when applicable. | | **Work type** | **Preventive maintenance** or **Inspection** | | **Recurrence** | How often work is generated (for example, **Weekly**, **On demand**) | | **Status** | **Active** or inactive | | **Tasks** | Number of tasks and total estimated time | ## Filter criteria These criteria are available in the **Filters** panel on the schedule list. | Filter | Description | | - | - | | **Next run date** | Date range for upcoming runs | | **Work type** | Preventive maintenance or Inspection | | **Inspection type** | Inspection category for inspection schedules | | **Assignee** | User assigned to generated work orders | | **Team assigned** | Team assigned to generated work orders | | **Frequency** | Recurrence pattern (for example, monthly, weekly) | | **Asset** | Asset included on the schedule | | **Asset type** | Type of asset included on the schedule | ## Work types | Work type | Description | | - | - | | **Preventive maintenance** | Recurring maintenance for building systems and assets | | **Inspection** | Routine site or asset walkthroughs to log findings | When you select **Inspection**, choose an inspection type. | Inspection type | Description | | - | - | | **Assets** | Inspect individual assets | | **Area** | Inspect rooms, floors, or common areas | | **General** | Catch-all for miscellaneous observations | ## Wizard steps | Step | Purpose | | - | - | | **General info** | Title, asset type, assignment, description, attachments | | **Schedule** | Timing, recurrence, due dates, and auto-fail | | **Assets** | Assets included on the schedule | | **Tasks** | Task templates or task groups for generated work orders | | **Overview** | Review settings before you create the schedule | ## General info fields **Title** `Field` *required* Name for the schedule. **Asset type** `Dropdown` *required* Asset types this schedule applies to. **Assignee** `Dropdown` User assigned to work orders the schedule generates. **Assign team** `Dropdown` Team assigned to work orders the schedule generates. Work orders assign to the entire team so members can assign work to themselves. **Description** `Field` Notes about the schedule scope or procedure. **Attachments** `Field` Files such as procedures or reference images. Select the upload area to add attachments. ## Timing and recurrence fields **Schedule type** `Dropdown` *required* **Just once**, **Recurrent**, or **On demand**. The fields below change based on your selection. **Start date and time** `Date` *required* When the schedule begins generating work. Enter a date between 1970 and 2099. The form checks the date as you enter it. **End date and time** `Date` Optional end date for the schedule window. **Due by days** `Field` *required* Number of days the assignee has to complete work after it is scheduled. **Frequency** `Dropdown` *required* Recurrence interval for recurrent schedules (for example, **Weekly**). Some frequencies support custom repeat options. For custom recurrence, set **Repeat on** (days of the week) and **On months** when those controls appear. ## Auto-fail fields **Auto-fail** `Toggle` When enabled, work orders auto-fail if not completed by the configured threshold. **Days after due date** `Field` *required* Days after the due date before auto-fail applies (shown when **Auto-fail** is on). ## Asset addition methods | Method | Description | | - | - | | **Add by asset type(s)** (recommended) | Includes all assets of the selected types. New assets of those types added later are included automatically. | | **Add by asset list** | Select specific assets from a searchable table. | ## Bulk edit fields Bulk edit updates only the fields you enable. Values apply to every selected schedule. **Assignee** `Dropdown` User assigned to work orders the selected schedules generate. **Team assigned** `Dropdown` Team assigned to work orders the selected schedules generate. **Auto-fail** `Dropdown` Auto-fail behavior for work orders created by the selected schedules. **Activation mode** `Dropdown` Activate or deactivate the selected schedules. **Due-by days** `Field` Number of days that set when generated work orders are due. **Next run date** `Date` Date that triggers the next schedule run. **Auto-fill** `Toggle` Force an immediate auto-fill across the selected schedules. ## Detail page tabs | Tab | Purpose | | - | - | | **Details** | General information, description, and timing | | **Attachments** | Files linked to the schedule | | **Tasks** | Task templates assigned to generated work orders | | **Assets** | Building assets included on the schedule | | **Logs** | History of work order batches the schedule created | ## Detail page fields **General information** shows these values. | Field | Description | | - | - | | Title | Schedule name | | Number | Schedule ID (for example, `SCH-00091`) | | Status | **Active** or inactive | | Assignee | User assigned to generated work orders | | Team assigned | Team assigned to generated work orders | | Created by | User who created the schedule | | Created at | Creation date | | Asset type | Asset types on the schedule (for example, **AHU**) | | Start date and time | When the schedule starts | **Schedule** shows timing and recurrence. | Field | Description | | - | - | | Next run | Next scheduled run date and time | | End by | End date for the schedule window | | Recurrence | Pattern (for example, weekly on Monday) | | Due by | Days to complete work after it is scheduled | | On month(s) | Months when recurrent runs apply | | Auto-fail | Days after due when work auto-fails | ## Related reference > [card] [Task fields](/products/assetops/reference/task-fields) > > Template and group fields you assign during schedule setup. > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Fields on the work orders a schedule generates. # Task template and group fields Source: https://docs.kodelabs.com/products/assetops/reference/task-fields Reference for AssetOps task template fields, task group fields, list columns, and import options Look up the fields that define reusable tasks in AssetOps. To create templates and groups, see [Tasks](/products/assetops/resources/task-templates). ## Template fields **Title** `Field` *required* Short name for the task. This text appears in the templates list and on work orders. **Work Type** `Dropdown` *required* Maintenance program for the template. Options include **Preventive Maintenance** and **Inspection**. **Estimated Time** `Field` Expected duration in hours and minutes. Helps planners estimate labor on schedules and dashboards. **Description** `Field` Detailed instructions for the assignee. Supports rich text formatting such as bold, lists, and links. Additional fields appear based on work type. Inspection templates add an **Inspection type** of **Asset**, **Area**, or **General**. ## Template list columns | Column | Description | | - | - | | **Title** | Task description or instruction shown on work orders | | **Work type** | Program: preventive maintenance or inspection | | **Estimated time** | Expected duration in hours and minutes | | **Asset type** | Equipment or location types the template applies to | ## Template detail fields The **General information** section of a template detail page shows these values. | Field | Description | | - | - | | **Title** | Template name | | **Work type** | Preventive maintenance or inspection | | **Asset type(s)** | Applicable asset types | | **Estimated time** | Duration assigned to the template | | **Author** | User who created the template | ## Task group fields **Name** `Field` *required* Display name for the task group. **Work Type** `Dropdown` *required* Maintenance program for all templates in the group. Templates must align with this work type. **Asset Type(s)** `Dropdown` Asset types the group applies to. Derived from the selected templates and general info step. **Inspection Type** `Dropdown` Shown for inspection groups. Values include **Asset**, **Area**, or **General**. ## Task group list columns | Column | Description | | - | - | | **Title** | Task group name | | **Task templates** | Count of templates in the group and combined estimated time | | **Asset type** | Asset types the group applies to | | **Work type** | Program such as preventive maintenance or inspection | | **Created by** | User who created the group | ## Import and export options | Action | Purpose | | - | - | | **Export** | Download existing templates | | **Import and Create** | Upload a file to add new templates in bulk | | **Import and Update** | Upload a file to add and update templates in one action | Starter files: * [Task Template Import](/downloads/task-template.xlsx) — Add new templates in bulk * [Task Template Import and Update](/downloads/task-template-import-update.xlsx) — Add and update templates together ## When to use groups | Approach | When to use | | - | - | | **Single template** | One repeatable task per schedule | | **Multiple templates** | Pick individual templates on a schedule | | **Task group** | Apply a fixed checklist of templates together | ## Related reference > [card] [Schedule fields](/products/assetops/reference/schedule-fields) > > Fields for the schedules that consume templates and groups. > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Task completion fields on generated work orders. # Work order fields and statuses Source: https://docs.kodelabs.com/products/assetops/reference/work-order-fields Reference for AssetOps work order statuses, list columns, filter criteria, bulk edit fields, and detail page fields Look up the values that repeat across AssetOps work order views. To create, filter, or manage work orders, see [Building work orders](/products/assetops/work-orders/work-orders-overview). For how work types differ, see [Work order basics](/products/assetops/quickstart/work-orders). ## Statuses Statuses drive the summary cards on both the [building](/products/assetops/work-orders/work-orders-overview) and [portfolio](/products/assetops/portfolio/work-orders) work order lists. **Overdue** is derived from the due date rather than set manually. | Status | Description | | - | - | | **Open** | Created but not yet started | | **In progress** | Currently being worked on | | **On hold** | Paused | | **For review** | Completed work awaiting review | | **Completed** | Finished work | | **Failed** | Work that did not complete successfully | | **Cancelled** | Cancelled work orders | | **Overdue** | Past due date and not completed | ## List columns The building work order list supports the full column set below. The portfolio list shows a subset by default and reveals the rest through the column control. | Column | Description | | - | - | | **Title** | Work order name as a link, with work order ID below (for example, `WO-10171`). An external-link icon opens the linked Cloud BMS device when applicable. | | **Status** | Current lifecycle status (for example, **Open**, **In progress**) | | **Work type** | Program type (for example, preventive maintenance, corrective maintenance, inspection) | | **Asset** | Asset the work applies to | | **Located in** | Building area or location hierarchy for the work | | **Priority** | Priority level from [Priority & SLA](/products/assetops/portfolio/priority-sla) | | **Schedule** | Source schedule name and ID when the work order came from a schedule (for example, `SCH-02238`) | | **Tasks** | Task count or summary for work on the order | | **Deficiency** | Linked deficiency or inspection finding when applicable | | **SLA status** | SLA state (for example, on track, warning, breached) | | **Created date** | Date the work order was created | | **Start date & time** | Scheduled or actual start | | **Due date & time** | Target completion date and time | | **Logged time** | Total time logged on the [logged time](/products/assetops/work-orders/work-orders-overview#logged-time) section of the detail page | | **Assignee** | User assigned to the work | | **Team assigned** | Team assigned to the work | | **Category & issue** | [Category](/products/assetops/resources/categories) and issue type | | **Follow up** | Indicates whether follow-up work is required or pending | ## Filter criteria These criteria are available in the **Filters** panel on the work order list. | Filter | Description | | - | - | | **Category** | Work order category (for example, HVAC, plumbing) | | **Issue type** | Issue type within a category | | **Assign team** | Team assigned to the work order | | **Assignee** | User assigned to the work order | | **Vendor** | Vendor assigned to the work order | | **Asset** | Asset associated with the work order | | **Asset type** | Type of asset associated with the work order | | **Area** | Area associated with the work order | | **Due date** | Due date range | | **Region** | Geographic or organizational grouping (portfolio lists) | ## Bulk edit fields Bulk edit updates only the fields you enable. Values apply to every selected work order. **Status** `Dropdown` Lifecycle status for selected work orders. Supports bulk completion when the status transition is valid. **Due date** `Date` Target due date and time for selected work orders. **Priority** `Dropdown` Priority level for selected work orders. **Assignee** `Dropdown` User assigned to the selected work orders. **Team assigned** `Dropdown` Team assigned to the selected work orders. **Completion date** `Date` Completion date for selected work orders. Use when completing work in bulk, including HSSE workflows. **Enter status note** `Field` Optional note recorded with a status change. ## Detail page fields The **General information** section of the [work order detail page](/products/assetops/work-orders/work-orders-overview#work-order-detail-page) shows these fields. | Field | Description | | - | - | | **Status** | Lifecycle status (for example, **Open**, **In progress**, **Completed**) | | **Start date & time** | When work is scheduled or started | | **Due date & time** | Target completion date and time | | **Completion date & time** | When the work order was completed | | **Work type** | Program type (for example, preventive maintenance, corrective maintenance) | | **Assignee** | User assigned to the work | | **Team assigned** | Team assigned to the work | | **Estimated time** | Planned duration for the work order | | **Schedule and log** | Link to the source [schedule](/products/assetops/schedules/schedules-overview#schedule-detail-page) log when the work order came from a schedule | | **Asset** | Link to the linked [asset](/products/assetops/assets/assets) record | | **Located in** | Building area for the work | | **Vendor** | Assigned vendor | | **Created by** | User who created the work order | | **Created at** | Creation date | ## Detail page tabs | Tab | Purpose | | - | - | | **Details** | General information, task checklist, and logged time | | **Attachments** | Files linked to the work order | | **Follow-ups** | Related and external follow-up work orders | ## Task completion fields When you mark a task **Done**, complete the compliance form. | Field | Description | | - | - | | **Compliant** | Whether the item inspected meets requirements (**Yes** or **No**) | | **Corrective action taken** | Whether corrective work was performed when not compliant | | **Note** | Required notes about the result | > [!NOTE] > > Which of these fields are mandatory depends on your [completion policies](/products/assetops/reference/completion-policy-options). ## Related reference > [card] [Asset fields](/products/assetops/reference/asset-fields) > > Fields on assets that work orders link to. > [card] [Notification events](/products/assetops/reference/notification-events) > > Work order events that can trigger alerts. # Portfolio-Wide Buildings Source: https://docs.kodelabs.com/products/assetops/resources/buildings View portfolio buildings and access the building-level The **Buildings** section at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) lists every building in your portfolio that uses AssetOps. Use it to review site details and open building-level operations for a specific property. ## View the buildings list Open **Buildings** from the portfolio sidebar to see all sites in a table. ![AssetOps Buildings page with search filtering results to KodeLabs HQ showing name, category, and address columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-buildings-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=8cd5c451f2142e5678cba03aa8dd8c39) The Buildings page lists each site with name, category, and address The table includes: | Column | Description | | - | - | | **Name** | Building display name (for example, KodeLabs HQ) | | **Category** | Building type (for example, Office) | | **Address** | Full street address for the property | ### Search buildings Use the search field in the top right to filter the list by building name or address. For example, type part of a name such as `kodela` to narrow results to **KodeLabs HQ** before you open the site. Select a row to open that building and work in building-level modules such as the [building dashboard](/products/assetops/building/dashboard), [work orders](/products/assetops/work-orders/work-orders-overview), and [assets](/products/assetops/assets/assets). ## Search and switch sites After you open a building, use the **site selector** in the top navigation bar to move between the portfolio and individual buildings without returning to the Buildings list. ![AssetOps site selector dropdown with search field, Portfolio all sites overview option, and filtered building search results](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-switch-site-selector.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=6f88fc383338e4e7269932917cb9fa7d) The site selector lets you search for a building or return to the portfolio overview ### Open the site selector Select the current site name in the top bar (for example, **KodeLabs HQ**) to open the dropdown. ### Portfolio overview Choose **Portfolio** with the subtitle **All sites overview** to return to portfolio-level navigation and modules such as [Dashboard](/products/assetops/portfolio/dashboard), **Buildings**, and [Work orders](/products/assetops/portfolio/work-orders). ### Search for a building 1. Open the site selector. 2. Type in the search field to filter buildings by name or address. 3. Select a building from the results to switch context to that site. The sidebar updates to building-level modules, including **Dashboard**, **Work orders**, **Schedules**, **Assets**, and **Teams**. > [!TIP] > > Use the site selector when you move between buildings frequently. Use the **Buildings** list when you need a full table view of every site in the portfolio. ## Next steps After you select a building, use the [building dashboard](/products/assetops/building/dashboard) and building-level modules. > [card] [Building dashboard](/products/assetops/building/dashboard) > > Monitor maintenance activity for the selected building. > [card] [Assets](/products/assetops/assets/assets) > > View and manage the assets associated with a building. > [card] [Work orders](/products/assetops/work-orders/work-orders-overview) > > Create and manage corrective maintenance work orders at the building level. # Categories & Issue Types Source: https://docs.kodelabs.com/products/assetops/resources/categories Categories and issue types for classifying and routing work orders In AssetOps, **categories** and **issue types** are created at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) and provide a consistent way to describe the type of maintenance job a work order represents. Categories define broad groups such as HVAC, electrical, or cleaning. Issue types represent specific problems or tasks within each category. This structure helps [route work](/products/assetops/resources/routing-dispatch) to the appropriate teams. You can assign categories and issue types when [creating corrective maintenance work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order). ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio-Level"] C["Categories"] end subgraph s2["Portfolio-Wide Categories"] C1["Electrical"] C4["Plumbing"] end subgraph s3["Category-Specific Issue"] I1["Exposed Wires"] I3["Circuit Overload"] end subgraph s5["Category-Specific Issue"] I7["Leaking Pipe"] I9["Clogged Drain"] end A["AssetOps"] --- B["Portfolio"] B -- access --- C C -- "portfolio-wide" --- C1 & C4 C1 -- issue types --- I1 & I3 C4 -- issue types --- I7 & I9 C:::Sky C1:::Rose C4:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none ``` Open **Categories** from the portfolio sidebar to open the **Categories & Issues** page. Use the **Categories** and **Issue types** tabs to manage each list. *** ## Categories A **category** is a broad work order group shared across the portfolio, such as HVAC, plumbing, or cleaning. Define categories before you create issue types that belong to them. ### View the categories list Select the **Categories** tab to see all categories. ![AssetOps Categories and Issues page with Categories tab showing a searchable list of category names and Add Category button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=d4eb05caa0cc903a6683fafe737c1b06) The Categories tab lists all portfolio categories with search and add actions The table includes a **Name** column for each category. Tab badges show the total category count. Use the search field to filter categories by name. Select the header checkbox to select all categories on the page for bulk actions. ### Add a category Select **+ Add Category** to open the creation dialog. ![Add Category modal with required Name field and Cancel and Create buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-add-modal.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=308b9cae7f8f8da2cba416cfa1372a83) Enter a name and select Create to add a new category **1. Open the Categories tab** In AssetOps, navigate to **Categories** and select the **Categories** tab. **2. Select + Add Category** Select **+ Add Category** in the top right. **3. Enter the category name** Enter the **Name** in the dialog. This field is required. **4. Create the category** Select **Create**. The new category appears in the list. ### Export categories Open the menu next to **+ Add Category** and select **Export** to download category data. ![Add Category button with overflow menu open showing Export option](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-export-menu.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=84b34dced7de9cf877714de4b4ddf88c) The overflow menu includes Export for category data ### Delete categories in bulk Select one or more categories using the row checkboxes, then select **Delete** to remove them. ![Categories tab with multiple categories selected and Delete button visible in the action bar](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-bulk-delete.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=881186b6d3c05c97544dc5e0ce10b206) Select categories with checkboxes, then use Delete for bulk removal ### Edit or delete a category Open the row menu on a category to **Edit** the name or **Delete** the category. *** ## Issue types An **issue type** is a specific maintenance problem or task within a category, such as **Air flow** under **HVAC** or **Leaking pipe** under **Plumbing**. Create categories first, then add issue types under each category. ### View the issue types list Select the **Issue types** tab to see all issue types and their parent categories. ![AssetOps Issue Types tab with Name and Category columns, search field, Filters button, and Add Issue Type button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-issue-types.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=b2754af97369e2360f5a0aec11683e54) The Issue Types tab lists each issue with its parent category | Column | Description | | - | - | | **Name** | Issue type display name (for example, Air Flow, After Hours) | | **Category** | Parent category the issue type belongs to | The tab badge shows the total issue type count. Use the search field to filter by name. Use **Filters** to narrow the list further. Pagination controls at the bottom help you navigate large libraries. The same issue name can exist under different categories when the work applies to multiple programs. Each row maps one issue type to one category. ### Add an issue type Select **+ Add Issue Type** to open the creation dialog. ![Add Issue Type modal with required Name and Category fields and Cancel and Create buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-portfolio-categories-add-issue-type-modal.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=63a20d2a2a7d74bd0839eba6e83c9145) Enter a name, select a category, and select Create to add an issue type **1. Open the Issue Types tab** In AssetOps, navigate to **Categories** and select the **Issue types** tab. **2. Select + Add Issue Type** Select **+ Add Issue Type** in the top right. **3. Enter name and category** Enter the **Name** and select the **Category** the issue type belongs to. Both fields are required. **4. Create the issue type** Select **Create**. The new issue type appears in the list. ### Edit or delete an issue type Open the row menu on an issue type to edit its name or category, or to delete it. Select multiple rows and use **Delete** for bulk removal. *** ## Related modules > [card] [Routing & dispatch](/products/assetops/resources/routing-dispatch) > > Route work orders to teams based on category and issue type. > [card] [Create work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order) > > Assign categories and issue types when creating corrective maintenance. # Routing and dispatch Source: https://docs.kodelabs.com/products/assetops/resources/routing-dispatch Automatically assign teams and users to work orders based on category and issue type **Routing & dispatch** automates work order assignment at the [building level](/products/assetops/quickstart/usage-workflow#building-level). When configured, selecting a category or issue type on a new work order pre-fills the **Assign team** and **Assignee** fields. You can override assignments manually during work order creation. > [!NOTE] > > Create [categories and issue types](/products/assetops/resources/categories) at the portfolio level before you configure routing rules. Create [teams](/products/assetops/resources/teams) at the building level for assignment targets. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio-Level"] C["Categories & Issue Types"] end subgraph s2["Building-Level"] R["Routing & Dispatch"] end subgraph s3["Routing Rules"] R1["HVAC → Facilities Team"] R2["Plumbing → Plumbing Team"] R3["Electrical → Electrical Team"] end C -- "inherited by" --- R R -- "assigns" --- R1 & R2 & R3 C:::Sky R:::Peach R1:::Rose R2:::Rose R3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Peach stroke-width:1px, stroke-dasharray:none, stroke:#FBB35A, fill:#FFEFDB, color:#8F632D ``` Open a building from [Buildings](/products/assetops/resources/buildings), then select **Routing & dispatch** in the building sidebar. ## How routing works Routing maps portfolio-level **categories** and **issue types** to a building-specific **team** and **assignee**. The page has two tabs: * **Categories** — Default assignment by category * **Issue types** — Assignment by specific issue type (overrides or refines category routing) When a user creates a [corrective maintenance work order](/products/assetops/work-orders/work-orders-overview#create-a-work-order) and selects a category or issue type, AssetOps applies the matching routing rule for that building. *** ## Categories The **Categories** tab lists every portfolio category and its routing assignment for the building. ![AssetOps Routing and Dispatch Categories tab with Category, Team Assigned, Assignee, and Status columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-categories.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=85a25b4edd279d6d889a51f6c233cddc) The Categories tab shows category assignments with team, assignee, and status | Column | Description | | - | - | | **Category** | Portfolio category name | | **Team assigned** | Team auto-assigned when this category is selected | | **Assignee** | User auto-assigned when this category is selected | | **Status** | **Active** or **Inactive** | Use **Search** to find categories. Select the edit icon on a row to configure assignment. ### Filter categories Select **Filters** to narrow the list. ![Routing and Dispatch Categories filters panel with Team Assigned, Assignee, and Active or Inactive status options](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-categories-filters.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=ef7156b8691c8ca86432f73010154a25) Filter routing rules by team, assignee, or status | Filter | Description | | - | - | | **Team assigned** | Show categories assigned to selected teams | | **Assignee** | Show categories assigned to selected users | | **Status** | **Active** or **Inactive** | Select **Clear all** to reset filters. ### Edit a category assignment Select the edit icon on a category row to open the assignment dialog. ![Edit Category modal with Assign Team, Assignee dropdowns and Active or Inactive status radio buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-edit-category.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=384f897dda711e889671a2f9f22dda40) Assign a team, assignee, and status for the category **Assign Team** `Dropdown` Team assigned when this category is selected on a work order. **Assignee** `Dropdown` User assigned when this category is selected. Optional if only a team is required. **Status** `Radio` **Active** applies the rule. **Inactive** disables automatic assignment for this category. **1. Open the Categories tab** Navigate to **Routing & dispatch** and select the **Categories** tab. **2. Edit a category** Select the edit icon on the category row you want to configure. **3. Set assignment** Choose **Assign team**, **Assignee**, and **Status**, then select **Save**. *** ## Issue types The **Issue types** tab lists every portfolio issue type with its parent category and routing assignment. ![AssetOps Routing and Dispatch Issue Types tab with Issue Types, Category, Team Assigned, and Assignee columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-issue-types.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a678710a66adc696530185db50b4fb8b) The Issue Types tab maps each issue to a team and assignee | Column | Description | | - | - | | **Issue types** | Issue type name | | **Category** | Parent category | | **Team assigned** | Team auto-assigned for this issue type | | **Assignee** | User auto-assigned for this issue type | Issue type rules can be more specific than category rules. When both exist, the issue type assignment typically takes precedence for that issue. ### Filter issue types ![Routing and Dispatch Issue Types filters panel with Category, Team Assigned, and Assignee dropdowns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-issue-types-filters.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e7d8e4beb9967b98ad342e604b585700) Filter issue types by category, team, or assignee | Filter | Description | | - | - | | **Category** | Show issue types under selected categories | | **Team assigned** | Show issue types assigned to selected teams | | **Assignee** | Show issue types assigned to selected users | ### Edit an issue type assignment Select the edit icon on an issue type row. ![Edit Issue Type modal with Category field, Assign Team, and Assignee dropdowns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-routing-edit-issue-type.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=9c9cf9943388fb838e582f6d7d6caa04) Assign team and assignee for a specific issue type **Category** `Dropdown` Parent category for the issue type (read-only or fixed based on portfolio configuration). **Assign Team** `Dropdown` Team assigned when this issue type is selected. **Assignee** `Dropdown` User assigned when this issue type is selected. **1. Open the Issue Types tab** Navigate to **Routing & dispatch** and select the **Issue types** tab. **2. Edit an issue type** Select the edit icon on the issue type row you want to configure. **3. Set assignment** Choose **Assign team** and **Assignee**, then select **Save**. *** ## Related modules > [card] [Categories](/products/assetops/resources/categories) > > Create portfolio categories and issue types that routing rules reference. > [card] [Teams](/products/assetops/resources/teams) > > Create building teams used as routing assignment targets. > [card] [Create work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order) > > Create corrective maintenance work orders that use routing for automatic assignment. # Tasks Source: https://docs.kodelabs.com/products/assetops/resources/task-templates Task templates and task groups for standardized preventive and inspection work In AssetOps, **tasks** are managed at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level). You define reusable work in **Templates**, then optionally bundle templates into **Task groups** for schedules that require a full checklist. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio-Level"] C["Tasks"] end subgraph s2["Templates & Groups"] T1["Task Templates"] T2["Task Groups"] end A["AssetOps"] --- B["Portfolio"] B -- access --- C C --- T1 & T2 T2 -- contains --- T1 T1 -- used on --- S["Schedules"] C:::Sky T1:::Rose T2:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none ``` Open **Tasks** from the portfolio sidebar. Use the secondary navigation to switch between **Templates** and **Task groups**. *** ## Task templates A **task template** is a reusable definition for work performed during preventive maintenance or inspections. Templates include instructions, estimated duration, applicable asset types, and optional attachments. When you [schedule](/products/assetops/schedules/schedules-overview) work at the building level, you assign templates so generated work orders include consistent tasks. ### View the templates list Select **Templates** under **Tasks** to open the task templates list. ![AssetOps Task Templates list with Title, Work Type, Estimated Time, and Asset Type columns, search, Filters, and Create Template button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-templates-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=343f1c47f67d5e1820e83ad38ab6a80f) The Task Templates page lists templates with work type, estimated time, and asset type | Column | Description | | - | - | | **Title** | Task description or instruction shown on work orders | | **Work type** | Program: preventive maintenance or inspection | | **Estimated time** | Expected duration in hours and minutes | | **Asset type** | Equipment or location types the template applies to | Use **Search** and **Filters** to find templates. Select row checkboxes for bulk edit. Pagination helps you navigate large libraries. ### Template fields When you create or edit a template, you configure the following fields. **Title** `Field` *required* Short name for the task. This text appears in the templates list and on work orders. **Work Type** `Dropdown` *required* Maintenance program for the template. Options include **Preventive Maintenance** and **Inspection**. **Estimated Time** `Field` Expected duration in hours and minutes. Helps planners estimate labor on schedules and dashboards. **Description** `Field` Detailed instructions for the assignee. Supports rich text formatting such as bold, lists, and links. Additional fields appear based on work type. See [Create templates by work type](#create-templates-by-work-type) below. ### Create templates by work type Select **+ Create Template** to open the creation dialog. ![New Task Template modal with Title, Work Type, Estimated Time hours and minutes fields, and rich text Description editor](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-templates-create-modal.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=2c3a2f24bf87b0f8066657ca275bea6b) Enter title, work type, estimated time, and description to create a template > [tab] Preventive maintenance > > **1. Open Templates** > > Navigate to **Tasks** and select **Templates**. > > **2. Select + Create Template** > > Select **+ Create Template**. > > **3. Set work type and asset types** > > Select **Preventive Maintenance** as **Work type**. Choose one or more **Asset types** the template applies to. > > **4. Add title, time, and description** > > Enter **Title**, **Estimated time**, and **Description**. > > **5. Create** > > Select **Create** to save the template. > [tab] Inspection > > **1. Open Templates** > > Navigate to **Tasks** and select **Templates**. > > **2. Select + Create Template** > > Select **+ Create Template**. > > **3. Set work type and inspection type** > > Select **Inspection** as **Work type**, then choose **Inspection type**: **Asset**, **Area**, or **General**. > > **4. Set asset types when required** > > If you select **Asset** as the inspection type, choose one or more **Asset types**. For **Area** or **General**, asset types are not required. > > **5. Add title, time, and description** > > Enter **Title**, **Estimated time**, and **Description**. > > **6. Create** > > Select **Create** to save the template. ### View and edit a template Select a template from the list to open its detail page. ![Task template details page with General Information including title, work type, asset types, and estimated time, plus Description and Attachments sections](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-template-details.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=993e90f082f47c02a217ed319607ea4e) The template details page shows general information, description, and attachments #### General information | Field | Description | | - | - | | **Title** | Template name | | **Work type** | Preventive maintenance or inspection | | **Asset type(s)** | Applicable asset types | | **Estimated time** | Duration assigned to the template | | **Author** | User who created the template | Select **Edit** in the **General information** section to update these fields. #### Description The **Description** section shows the full task instructions, including formatted content from the rich text editor. #### Attachments The **Attachments** section stores reference files such as procedures, diagrams, or forms. * Select **Upload** to add files to the template. * Attachments copy to work orders that use the template when your organization configures that behavior. #### Other actions Use the menu in the upper right corner of the page to delete the template. **1. Open a template** From **Templates**, select the template you want to change. **2. Edit or attach files** Select **Edit** to update fields, or **Upload** to add attachments. **3. Save changes** Save your updates. Existing schedules that reference the template use the updated definition for new work orders according to your configuration. ### Import, export, and bulk update #### Import and export Open the menu next to **+ Create Template**. ![Create Template button with overflow menu showing Export, Import and Create, and Import and Update options](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-templates-import-export.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=72a627e36a207908b0ed40fe38aa8624) Export, import and create, or import and update templates from the overflow menu | Action | Purpose | | - | - | | **Export** | Download existing templates | | **Import and Create** | Upload a file to add new templates in bulk | | **Import and Update** | Upload a file to add and update templates in one action | Download starter files: * [Task Template Import](/downloads/task-template.xlsx) — Add new templates in bulk * [Task Template Import and Update](/downloads/task-template-import-update.xlsx) — Add and update templates together #### Bulk edit Select one or more templates using row checkboxes, then select **Edit**. ![Edit Task Templates modal with checkboxes to update estimated time and asset types for all selected templates on the page](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-templates-bulk-edit.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9c62de48cd482a90e9671c13b754a78c) Bulk edit applies estimated time and asset type changes to all selected templates > [!WARNING] > > Changes in bulk edit apply to every selected template that passes validation. Review the selection count before you save. Enable **Estimated time** or **Asset type(s)**, enter the new values, and select **Save**. Bulk updates run as a batch. Failed rows remain available to review and export with failure reasons. A progress popup confirms when processing starts, and the seven-day bulk history records who ran the update and the success and failure counts. You can select all templates on the current page, then use the banner option to extend the selection to every template in the library. #### Bulk delete unused templates Select unused task templates that are not linked to active schedules, then delete them in bulk. Templates that are still used on live schedules are not removed; those rows appear as failures in the batch result and exportable report. ### Use templates on schedules Assign templates when you create building-level schedules: * [Building schedules](/products/assetops/schedules/schedules-overview#create-a-schedule) Each generated work order includes the tasks from the templates you selected. Define templates at the portfolio level first, then reference them during schedule configuration. *** ## Task groups A **task group** bundles multiple task templates that share a **Work type** and apply to the same asset types. Use a group when scheduled work always requires the same set of tasks, such as a multi-step inspection or preventive maintenance checklist across several asset types. | Approach | When to use | | - | - | | **Single template** | One repeatable task per schedule | | **Multiple templates** | Pick individual templates on a schedule | | **Task group** | Apply a fixed checklist of templates together | ### View the task groups list Select **Task groups** in the Tasks secondary navigation. ![AssetOps Task Groups list with Title, Task Templates count, Asset Type, Work Type, and Created By columns](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-groups-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=bc9177bd1248ac5ac917c0ab77ba43b3) The Task Groups page lists groups with template count, asset types, and work type | Column | Description | | - | - | | **Title** | Task group name | | **Task templates** | Count of templates in the group and combined estimated time | | **Asset type** | Asset types the group applies to | | **Work type** | Program such as preventive maintenance or inspection | | **Created by** | User who created the group | Use **Search** and **Filters** to find groups. Select **+ Create Task Group** to add a new group. ### Task group fields During creation and on the details page, a task group includes: **Name** `Field` *required* Display name for the task group. **Work Type** `Dropdown` *required* Maintenance program for all templates in the group. Templates must align with this work type. **Asset Type(s)** `Dropdown` Asset types the group applies to. Derived from the selected templates and general info step. **Inspection Type** `Dropdown` Shown for inspection groups. Values include **Asset**, **Area**, or **General**. ### Create a task group Creating a task group uses a three-step wizard: **General info**, **Task templates**, and **Overview**. #### Step 1: General info ![Create Task Group modal step one General Info with Name and Work Type fields](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-group-create-step1.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ea9991395d1eaf7c7612e4f7baa017cd) Enter the task group name and work type in the first step **1. Select + Create Task Group** On the **Task groups** page, select **+ Create Task Group**. **2. Enter name and work type** Enter **Name** and **Work type**. For inspection groups, set **Inspection type** when prompted. **3. Continue** Select **Choose Task Templates** to go to step 2. #### Step 2: Task templates ![Create Task Group modal step two Task Templates with search field, template list with Title and Est Time columns, and two templates selected](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-group-create-step2.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=1d08ec5669c079ddb61c2838bf41a073) Search and select task templates to include in the group Search for templates, then select checkboxes for each template to include. The header checkbox shows how many templates are selected. Only templates that match the group's work type appear. Select **Add Task Templates** to continue. Use **Back** to change general info. #### Step 3: Overview ![Create Task Group modal step three Overview showing Name, Work Type, Inspection Type, Asset Type, and Estimated Time summary with Create button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-group-create-step3.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=1056fbb739187722f70028c63c897773) Review task group details before you create the group The **Overview** step summarizes: * **Name** and **Work type** * **Inspection type** — For inspection groups * **Asset type** — Asset types linked to the group * **Estimated time** — Template count and combined duration (for example, `2 tasks · 24h 44m`) Select **Create** to save the group, or **Back** to change earlier steps. ### View and manage a task group Select a group from the list to open its details page. ![Multiple Asset Task Group details with General Information section and Task Templates table with Reorder and Add Task Templates actions](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-tasks-group-details.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ccf51959d881c687f9bee0b0eda0c637) The task group details page shows general information and linked task templates #### General information Review **Name**, **Work type**, **Asset type(s)**, **Task templates** count, total estimated time, and **Created by**. Select **Edit** to update the group name or work type. #### Templates in the group The **Task templates** table lists each template in execution order. | Column | Description | | - | - | | **Title** | Template name | | **Estimated time** | Duration for that task | | **Asset type** | Asset types for the template | | Action | Purpose | | - | - | | **Reorder** | Change the sequence tasks appear on work orders | | **+ Add Task Templates** | Include additional templates in the group | | **Remove** | Detach a template from the group using the row remove control | Use search within the section to find templates in large groups. **1. Open a task group** From **Task groups**, select the group you want to manage. **2. Add or reorder templates** Select **+ Add Task Templates** to attach templates, or **Reorder** to change task sequence. **3. Save changes** Confirm additions or reordering. The group's total estimated time updates based on included templates. ### Edit or delete a task group * Select **Edit** on the details page to change group metadata. * Open the menu in the upper right corner to delete the group. > [!WARNING] > > Deleting a task group does not delete the task templates it references. Schedules that already use the group may require updated task assignments. ### Use task groups on schedules When you [create a schedule](/products/assetops/schedules/schedules-overview#create-a-schedule), you can assign a task group instead of selecting individual templates. The schedule applies every template in the group to generated work orders. Define templates first, bundle them into groups when needed, then reference the group during schedule setup at the building level. *** ## Related modules > [card] [Schedules](/products/assetops/schedules/schedules-overview) > > Assign templates and task groups when you schedule recurring work. > [card] [Categories](/products/assetops/resources/categories) > > Classify work orders that include tasks from templates and groups. > [card] [Task fields](/products/assetops/reference/task-fields) > > Look up template and task group field definitions. # Teams Source: https://docs.kodelabs.com/products/assetops/resources/teams Manage teams and assignees at the building level In AssetOps, **teams** are created at the [building level](/products/assetops/quickstart/usage-workflow#building-level). A team is a group of users who complete work orders assigned to that team at a specific building. Teams are organized by purpose, such as HVAC, plumbing, or security. You assign teams when [creating work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order) or [scheduling](/products/assetops/schedules/schedules-overview) maintenance. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Buildings"] B1["Building 1"] B2["Building 2"] B3["Building 3"] end subgraph s2["Building-Specific Teams"] T1["Plumbing Team"] T2["Electrical Team"] T3["Cleaning Team"] end A["AssetOps"] --- B["Buildings"] B -- access --- B1 & B2 & B3 B2 -- access --- T["Teams"] T -- "building-specific" --- T1 & T2 & T3 B1:::Sky B2:::Sky B3:::Sky T1:::Rose T2:::Rose T3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00,fill:none linkStyle 7 stroke:#FF6D00,fill:none ``` Open a building from [Buildings](/products/assetops/resources/buildings), then select **Teams** in the building sidebar. ## View the teams list The **Teams** page lists every team for the selected building. ![AssetOps Teams page for KodeLabs HQ with Name and Members columns, search field, and Add Team button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-teams-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=858b6f98fdd1cdfefc8cb54df2aff384) The Teams page lists team names and member counts with search and add actions | Column | Description | | - | - | | **Name** | Team display name | | **Members** | Number of users assigned to the team | Use the search field to filter teams by name. Select **+ Add Team** to create a new team. ## Create a team Creating a team uses a two-step flow: **General info** and **Assign members**. ### Step 1: General info ![Add Team modal step one General Info with Name and Description rich text fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-teams-create-step1.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=882dbb00c60fc964790eaad59ac285b5) Enter the team name and description **Name** `Field` *required* Display name for the team, such as HVAC or Plumbers. **Description** `Field` Optional details about the team's responsibilities. Supports rich text formatting. **1. Open Teams** From the portfolio level, open a [building](/products/assetops/resources/buildings), then select **Teams**. **2. Select + Add Team** Select **+ Add Team** in the top right. **3. Enter general info** Enter **Name** and **Description**, then select **Continue**. ### Step 2: Assign members ![Add Team modal step two Assign members with searchable user list, Position column, and Lead Member toggles](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-teams-create-step2.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=75134dc15ed042dd15c9d891ea4c946e) Search for users and assign them to the team Search for users, then select checkboxes for each member to add. The table includes: | Column | Description | | - | - | | **Name** | User display name | | **Email** | User email address | | **Position** | Role or title, if provided | | **Lead member** | Toggle to designate the team lead | > [!NOTE] > > Enable **Lead member** for one or more users who coordinate work for the team. Select **Create** to save the team. Use **Back** to change general info, or **Cancel** to exit. ## Team details Select a team from the list to open its details page. ![PLUMBERS team details with General Information section and empty Members table with Assign button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-teams-details.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=beac8a35e3565fe8ad4faf271fbfdad0) The team details page shows general information and assigned members ### General information Review **Name** and **Description**. Select **Edit** to update team details. Use the menu in the upper right corner to delete the team. ### Members The **Members** section lists users assigned to the team. | Column | Description | | - | - | | **Name** | Member display name | | **Position** | Role or title | | **Email** | Contact email | | **Phone number** | Contact phone, if provided | | **Lead member** | Whether the user is a team lead | Select **Assign** to add members after the team is created. Use search to find users in large teams. ### Unassign a member Open the row menu on a member and select **Unassign** to remove that user from the team. ![Team members table row menu showing Unassign option and Lead Member toggle](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-teams-unassign.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=046474c5fb1e517e17fecf0d26e88575) Use the row menu to unassign a member or toggle lead member status Toggle **Lead member** on or off directly in the table to change team lead designation without unassigning the user. ## Related modules > [card] [Work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order) > > Assign teams when you create work orders at the building level. > [card] [Routing & dispatch](/products/assetops/resources/routing-dispatch) > > Route work to teams automatically based on category and rules. # Vendors Source: https://docs.kodelabs.com/products/assetops/resources/vendors Manage vendors for your AssetOps portfolio In AssetOps, **vendors** are created at the [portfolio level](/products/assetops/quickstart/usage-workflow#portfolio-level) and represent the external companies and service providers that carry out maintenance activities. Vendors are shared across all buildings in your portfolio, providing a single, consistent list available throughout. Adding vendors and assigning users as vendor members allows you to link the right provider to work orders and track who is responsible for outsourced maintenance and repairs. You can assign vendors when [creating work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order). ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Portfolio-Level"] P["Vendors"] end subgraph s2["Portfolio-Wide Vendors"] V1["Vendor 1"] V2["Vendor 2"] V3["Vendor 3"] end A["AssetOps"] --- B["Portfolio"] B -- access --- P P -- "shared across buildings" --- V1 & V2 & V3 P:::Sky V1:::Rose V2:::Rose V3:::Rose classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00,fill:none ``` ## View the vendors list Open **Vendors** from the portfolio sidebar to see all vendors in your portfolio. ![AssetOps Vendors page with name and website columns, search field, and Add Vendor button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-vendors-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=4d16aee26588ca0d15dd6ff953b7a5c0) The Vendors page lists each vendor with name and website, and includes search and add actions The table includes: | Column | Description | | - | - | | **Name** | Vendor display name | | **Website** | Vendor website URL, if provided | Use the search field to filter vendors by name. Select **+ Add Vendor** in the top right to create a new vendor. ## Add vendors **1. Open the Vendors section** In AssetOps, navigate to **Vendors** in the portfolio-level sidebar. **2. Click + Add Vendor** On the Vendors page, select **+ Add Vendor** to open the creation form. **3. Enter vendor details** Enter the **Name** (required) and **Website** (optional) for the new vendor. **4. Create** Select **Create** to add the vendor. The new vendor appears in the list. ## Vendor details and members Select a vendor from the list to open its details page. The **Details** tab shows general information and assigned members. ![AssetOps vendor details page for KODE Labs with General Information section and Members table with Assign button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/assetops/assetops-portfolio-vendors-details.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=d3f6c0863e79f8cd90cc1368dae6930b) The vendor details page shows general information and a searchable members table ### General information The **General information** section displays the vendor **Name** and **Website**. Select **Edit** to update these fields. ### Members The **Members** section lists users assigned to the vendor. Members can receive and manage work orders linked to that vendor. | Column | Description | | - | - | | **Name** | Member display name | | **Position** | Role or title, if provided | | **Email** | Contact email | | **Phone number** | Contact phone, if provided | Use the search field to find members. Select **+ Assign** to add users to the vendor. > [!NOTE] > > User profiles for vendor members are [created and managed in Launchpad](/products/launchpad/client-organizations/users#create-users). Assign existing users on the vendor details page. ## Assign members **1. Open the Vendors section** In AssetOps, navigate to **Vendors** in the portfolio-level sidebar. **2. Select a vendor** Select a vendor from the list to open its details page. **3. Assign users** In the **Members** section, select **+ Assign** and choose the users you want to assign as vendor members. **4. Save** Select **Save** to confirm the assignment. ## Manage vendors On the vendor details page, you can edit vendor information, manage members, or remove the vendor. * Select **Edit** in the **General information** section to update the vendor name or website. * Select the menu icon in the upper right corner to delete the vendor. * Use the row menu on a member to unassign that user from the vendor. * Select **+ Assign** to add additional members. ## Related modules > [card] [Work orders](/products/assetops/work-orders/work-orders-overview#create-a-work-order) > > Assign vendors when you create work orders at the building level. > [card] [Buildings](/products/assetops/resources/buildings) > > Open a building to use vendors in building-level operations. # Building schedules Source: https://docs.kodelabs.com/products/assetops/schedules/schedules-overview Create and manage preventive maintenance and inspection schedules at the building level in AssetOps At the [building level](/products/assetops/quickstart/usage-workflow#building-level), **Schedules** generate recurring or on-demand [work orders](/products/assetops/work-orders/work-orders-overview) for preventive maintenance and inspections. Open a building from [Buildings](/products/assetops/resources/buildings), then select **Schedules** in the sidebar. Schedules use [task templates](/products/assetops/resources/task-templates) and [teams](/products/assetops/resources/teams) you configure at the portfolio level. *** ## Schedule list The default **list** view shows all schedules for the building. ![Building Schedules list view with search, list and calendar toggles, Filters, and Create button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=fb088afedf087ab0526c8c84bb6e328d) Schedules list with title, work type, recurrence, status, and task counts | Column | Description | | - | - | | **Title** | Schedule name as a link, with schedule ID below (for example, `SCH-02235`). An external-link icon opens the linked Cloud BMS device when applicable. | | **Work type** | **Preventive maintenance** or **Inspection** | | **Recurrence** | How often work is generated (for example, **Weekly**, **On demand**) | | **Status** | **Active** or inactive | | **Tasks** | Number of tasks and total estimated time | Use **Search schedules** to find records. Use the column control to show or hide fields. ### Bulk edit schedules Update multiple schedules at once from the list at the building or [portfolio](/products/assetops/portfolio/schedules) level. Bulk updates run as a **batch**: AssetOps processes each selected schedule individually. Valid items complete even when some rows fail. Failed rows stay available to review and export with the failure reason. When you start a batch, a popup confirms that processing started. If another bulk update is already running, the new job is queued. Review the seven-day **Bulk History** for who triggered the update, success and failure counts, and exportable failure details. Bulk History is available on building and portfolio schedule lists. A badge shows whether the batch finished fully or stopped because of an interruption. Select one or more rows, then select **Edit**. ![Bulk Edit modal with warning banner and checkboxes for Assignee, Team Assigned, and Auto-fail fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-bulk-edit.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e0d864a83d83b685edc2dc2b7881e8ee) Bulk Edit modal updates assignee, team, and auto-fail for selected schedules > [!WARNING] > > Only checked fields are updated. Review your selection and field choices before you save. Enable the checkbox next to each field you want to change. Only checked fields are updated on selected schedules that pass validation. **Assignee** `Dropdown` User assigned to work orders the selected schedules generate. **Team assigned** `Dropdown` Team assigned to work orders the selected schedules generate. **Auto-fail** `Dropdown` Auto-fail behavior for work orders created by the selected schedules. **Activation mode** `Dropdown` Activate or deactivate the selected schedules. **Due-by days** `Field` Number of days that set when generated work orders are due. **Next run date** `Date` Date that triggers the next schedule run. **Auto-fill** `Toggle` Force an immediate auto-fill across the selected schedules. **1. Select schedules** Use row checkboxes or the header checkbox to select schedules in the list. **2. Open Bulk edit** Select **Edit** in the toolbar. **3. Choose fields to update** Enable the checkbox for each field you want to change. Select values only for checked fields. You can set activation mode, due-by days, next run date, and auto-fill in addition to assignee, team, and auto-fail. **4. Save and review** Select **Save** to start the batch, or **Cancel** to close without saving. Confirm progress in the popup, then use the seven-day bulk history to export any failed rows. ### Calendar view Select the **calendar** view toggle to see scheduled work on a monthly grid. ![Schedules calendar view for May 2026 with colored schedule chips and Today navigation](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-calendar.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a13981a755966e1edbcef0d69de2546f) Calendar view shows schedule items by day with maintenance and inspection icons Use **Today**, month arrows, or the date picker to move between periods. Days with many schedules show a **+N more** link to expand the list. ### Filters Select **Filters** to open the filter panel. ![Schedules filters sidebar with Next Run Date, Work Type, Inspection Type, Assignee, Team Assigned, Frequency, and Asset fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-filters.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=2b4c6e3b4d8bad7aed0392d7db8d55b3) Filter schedules by date, work type, assignee, team, frequency, and asset | Filter | Description | | - | - | | **Next run date** | Date range for upcoming runs | | **Work type** | Preventive maintenance or Inspection | | **Inspection type** | Inspection category for inspection schedules | | **Assignee** | User assigned to generated work orders | | **Team assigned** | Team assigned to generated work orders | | **Frequency** | Recurrence pattern (for example, monthly, weekly) | | **Asset** | Asset included on the schedule | | **Asset type** | Type of asset included on the schedule | Select **Clear all** to reset filters. ### Export Open the vertical ellipsis menu in the schedule list header and select **Export** to download schedule data. *** ## Create a schedule Select **+ Create** to start a new schedule. To add many schedules at once, [import them from a spreadsheet](#import-schedules-from-a-spreadsheet). ### Choose work type ![Create Schedule modal with Preventive Maintenance and Inspection work types plus Assets Area and General inspection type options](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-create-inspection-type.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=2e40ec1c97c654a440f916ff1d155e4d) Select Preventive Maintenance or Inspection, then choose an inspection type when applicable | Work type | Description | | - | - | | **Preventive maintenance** | Recurring maintenance for building systems and assets | | **Inspection** | Routine site or asset walkthroughs to log findings | When you select **Inspection**, choose an **Inspection type**: | Inspection type | Description | | - | - | | **Assets** | Inspect individual assets | | **Area** | Inspect rooms, floors, or common areas | | **General** | Catch-all for miscellaneous observations | Select **Continue** to open the **New schedule** wizard. ### Wizard overview The wizard has five steps: | Step | Purpose | | - | - | | **General info** | Title, asset type, assignment, description, attachments | | **Schedule** | Timing, recurrence, due dates, and auto-fail | | **Assets** | Assets included on the schedule | | **Tasks** | Task templates or task groups for generated work orders | | **Overview** | Review settings before you create the schedule | *** ### Step 1: General info ![New Schedule wizard step General Info with Title, Asset Type, Assignee, Assign Team, Description, and Attachments fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-general.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e88bc90f40aee211ff61a168d0348f25) General info step with title, asset type, assignee, team, description, and attachments **Title** `Field` *required* Name for the schedule. **Asset type** `Dropdown` *required* Asset types this schedule applies to. **Assignee** `Dropdown` User assigned to work orders the schedule generates. **Assign team** `Dropdown` Team assigned to work orders the schedule generates. Work orders assign to the entire team so members can assign work to themselves. **Description** `Field` Notes about the schedule scope or procedure. **Attachments** `Field` Files such as procedures or reference images. Select the upload area to add attachments. Select **Next** to continue. *** ### Step 2: Schedule Configure when and how often the schedule runs. ![New Schedule wizard Schedule step with Recurrent type, dates, Due By Days, Weekly frequency, Repeat On Monday, and Auto-fail toggle](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-schedule.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=cd39f0b55dd06902ee2763d5c829a0bc) Schedule step with recurrent timing, frequency, repeat days, months, and auto-fail **Schedule type** `Dropdown` *required* **Just once**, **Recurrent**, or **On demand**. The fields below change based on your selection. **Start date and time** `Date` *required* When the schedule begins generating work. Enter a date between 1970 and 2099. The form checks the date as you enter it. **End date and time** `Date` Optional end date for the schedule window. **Due by days** `Field` *required* Number of days the assignee has to complete work after it is scheduled. **Frequency** `Dropdown` *required* Recurrence interval for recurrent schedules (for example, **Weekly**). Some frequencies support custom repeat options. For custom recurrence, set **Repeat on** (days of the week) and **On months** when those controls appear. **Auto-fail** `Toggle` When enabled, work orders auto-fail if not completed by the configured threshold. **Days after due date** `Field` *required* Days after the due date before auto-fail applies (shown when **Auto-fail** is on). Select **Next** to continue. *** ### Step 3: Assets Choose how assets are included on the schedule. ![New Schedule Assets step with Add by asset types recommended and Add by asset list options](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-assets.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=b0b3fdc4311147a5016505a6eacf08e0) Add assets by asset type or by selecting individual assets from a list | Method | Description | | - | - | | **Add by asset type(s)** (recommended) | Includes all assets of the selected types. New assets of those types added later are included automatically. | | **Add by asset list** | Select specific assets from a searchable table. | When you use **Add by asset list**, search and filter the table, then select rows. ![Assets step with Search Assets, Filter by Level, Filter by Located In, and asset table columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-assets-filters.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=99126b508d9c540271782cc8c5940752) Filter assets by level and location when adding by list ![Assets step with three assets selected showing Title, Asset Type, and Located In columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-assets-selected.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a27a79dc744545aa87aa7b137f899006) Select individual assets with checkboxes before continuing Use **Select all** to include every asset in the current filtered list. Select **Next** when your asset selection is complete. *** ### Step 4: Tasks Assign work that each generated work order should include. ![New Schedule Tasks step with Tasks and Task Groups tabs, search, and Selected Tasks panel](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-tasks.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=01b5745003f0247cd3a52bdf0fad22e1) Tasks step with task list, search, and selected tasks panel Two tabs are available: | Tab | Description | | - | - | | **Tasks** | Select individual [task templates](/products/assetops/resources/task-templates) | | **Task groups** | Select a predefined group of templates | Search tasks, select rows, then use the arrow control to move tasks into **Selected tasks**. The template selection table includes an `Asset Type` column. Select **Confirm** after search if needed. Select **Next** when at least one task is selected. *** ### Step 5: Overview Review general info, schedule timing, and selected tasks before you create the schedule. The overview shows title, recurrence, due rules, and selected tasks in read-only summary sections. Select **Back** to change a prior step, **Cancel** to exit, or **Create** to save the schedule. ![Overview step footer with Back, Cancel, and Complete buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedules-wizard-complete.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=2b14b30c68dc2b16a804eba65c51d539) Complete the wizard to create the schedule *** ## Import schedules from a spreadsheet You can import schedules in bulk from a spreadsheet that follows a predefined template. **1. Prepare the spreadsheet** Enter schedule data in the predefined template. **2. Upload the spreadsheet** Upload the completed file. AssetOps checks the data automatically. **3. Review feedback** When the import finishes, you receive success or error feedback. Problems in the file are flagged so you can fix them and import again. *** ## Schedule detail page Select a schedule **Title** from the building list or calendar to open the schedule detail page. From the [portfolio schedules](/products/assetops/portfolio/schedules) list or calendar, select the **Title** link or the external-link icon beside the title to open the same detail page in this building context. The header shows the schedule name, a back control, and a menu for additional actions. Five tabs organize schedule content: | Tab | Purpose | | - | - | | **Details** | General information, description, and timing | | **Attachments** | Files linked to the schedule | | **Tasks** | Task templates assigned to generated work orders | | **Assets** | Building assets included on the schedule | | **Logs** | History of work order batches the schedule created | ### Details tab ![Weekly Schedule Details tab showing General Information with status and assignee, and Schedule section with recurrence and auto-fail](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-details.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=df2dfffcc1a998b6e30b586cc0e600c1) Details tab with general information, description, and schedule timing sections **General information** includes: | Field | Description | | - | - | | Title | Schedule name | | Number | Schedule ID (for example, `SCH-00091`) | | Status | **Active** or inactive | | Assignee | User assigned to generated work orders | | Team assigned | Team assigned to generated work orders | | Created by | User who created the schedule | | Created at | Creation date | | Asset type | Asset types on the schedule (for example, **AHU**) | | Start date and time | When the schedule starts | Select the icon on **General information** or **Schedule** to edit those sections. **Description** holds optional notes about the schedule. **Schedule** shows timing and recurrence: | Field | Description | | - | - | | Next run | Next scheduled run date and time | | End by | End date for the schedule window | | Recurrence | Pattern (for example, weekly on Monday) | | Due by | Days to complete work after it is scheduled | | On month(s) | Months when recurrent runs apply | | Auto-fail | Days after due when work auto-fails | ### Attachments tab ![Weekly Schedule Attachments tab with Upload button and attachment card showing date uploader and filename](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-attachments.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e87eb1807230a73c52fd200781e93c1a) Attachments tab with Upload and file cards * Select **Upload** to add files to the schedule. * Each card shows upload date, uploader, and file name. * Use the row menu on a card for file actions. ### Tasks tab ![Weekly Schedule Tasks tab with task table showing Title, Asset Types, and Estimated Time columns plus Add Task button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-tasks.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=09b707402be93281aa37fe17551058ac) Tasks tab lists assigned templates with search, reorder, and Add Task | Column | Description | | - | - | | **Title** | Task name or instruction text | | **Asset types** | Asset types the task applies to | | **Estimated time** | Expected duration for the task | Use **Search** to find tasks. Select **Reorder** to change task order on generated work orders. Select **+ Add task** to assign templates from your portfolio library. ![Add Task split button menu showing Add Custom Task option](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-add-custom-task.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=21a265f48c9b0941e5e0932b15450a80) Add Task dropdown includes Add Custom Task | Option | Description | | - | - | | **Add task** | Open the task picker to select existing [task templates](/products/assetops/resources/task-templates) | | **Add custom task** | Create a one-off task for this schedule only | ![Add Task modal with searchable task table, Title and Asset Types columns, and Save button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-add-task.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=662d54860892fafa4b02e46c8abed2d3) Add Task modal lists templates with asset types and external links Select tasks in the modal, then select **Save** to add them to the schedule. ### Assets tab ![Weekly Schedule Assets tab with asset table showing Title, Asset Type AHU, and Area columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-assets.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e6d1adb79478590ae177cb8df8315d3d) Assets tab lists building assets on the schedule with Add Asset | Column | Description | | - | - | | **Title** | Asset name on the schedule | | **Asset type** | Asset type for the record | | **Area** | Building area for the asset | Select **+ Add asset** to include more assets. Use **Search** to filter the list. ![Assets tab menu showing Edit Addition Method option next to Add Asset button](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-assets-menu.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=fba8d0081a0cf8831f9bcf3c156232ad) Edit addition method changes how assets are added to the schedule **Edit addition method** switches between adding by asset type and adding by asset list, matching the options in the [create wizard](#step-3-assets). ### Logs tab ![Weekly Schedule Logs tab with Number, Work Orders, and Created At columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-schedule-logs.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=edc2193beeb33fd5b2b3d6207f98482f) Logs tab shows work order generation history by run number and date | Column | Description | | - | - | | **Number** | Log entry ID for the schedule run (for example, `SCH-00017-001`) | | **Work orders** | Count of work orders created in that run | | **Created at** | Date the batch was generated | Open a log entry to review work orders created for that run. *** ## Manage schedule status From the **Details** tab you can: * Change **Status** between **Active** and inactive * Edit general information and schedule timing * **Trigger** on-demand schedules manually when the schedule type is on demand > [!NOTE] > > Inactive schedules do not generate new work orders. Existing work orders already created remain unchanged. *** ## Related modules > [card] [Task templates](/products/assetops/resources/task-templates) > > Define reusable tasks and task groups for schedules. > [card] [Work orders](/products/assetops/work-orders/work-orders-overview) > > View work orders generated from schedules. > [card] [Assets](/products/assetops/assets/assets) > > Review assets included on schedules and linked devices. > [card] [Teams](/products/assetops/resources/teams) > > Assign teams that receive scheduled work orders. > [card] [Schedule fields](/products/assetops/reference/schedule-fields) > > Look up schedule columns, recurrence options, and field definitions. # Building work orders Source: https://docs.kodelabs.com/products/assetops/work-orders/work-orders-overview View, filter, create, and manage building-level work orders in AssetOps At the [building level](/products/assetops/quickstart/usage-workflow#building-level), **Work orders** is the hub for planned and unplanned maintenance. Open a building from [Buildings](/products/assetops/resources/buildings), then select **Work orders** in the sidebar. When AssetOps is enabled, you can also open **Work orders** from the [KODE OS building sidebar](/products/kode-os/assetops/work-orders) without leaving KODE OS. Work orders can come from corrective requests, [schedules](/products/assetops/schedules/schedules-overview), or integrations. Learn how work types differ in [Work order basics](/products/assetops/quickstart/work-orders). *** ## Work order list The work orders page shows status summary cards, a searchable table, and actions to create or manage work. ![Building Work Orders page with status summary cards, Focus Mode toggle, search bar, and work order table](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-orders-list.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=6b034fbb339bb6c8887a05735c0df4b8) Work orders list with status cards, Focus mode toggle, search, and table columns ### Status summary cards Select a card to filter the table by that status. Counts update based on your current filters. | Status | Description | | - | - | | **Open** | Created but not yet started | | **In progress** | Currently being worked on | | **On hold** | Paused | | **For review** | Completed work awaiting review | | **Completed** | Finished work | | **Failed** | Work that did not complete successfully | | **Cancelled** | Cancelled work orders | | **Overdue** | Past due date and not completed | ### List actions * **Search** — Filter the table by text across visible fields * **Focus mode** — Toggle to show only urgent work. See [Focus mode](#focus-mode). * **Filters** — Open custom filter criteria. See [Custom filters](#custom-filters). * **+ Create work order** — Start a new work order. See [Create a work order](#create-a-work-order). * **Edit** and **Delete** — Available when you select one or more rows * Vertical ellipsis menu — Additional list actions such as **Export** Select row checkboxes to enable bulk **Edit** or **Delete**. See [Bulk edit work orders](#bulk-edit-work-orders). ### Export Open the vertical ellipsis menu in the list header and select **Export** to download work order data. ![Work orders table showing Title with WO ID, Status, Work Type, Asset, Located In, Priority, and Schedule columns](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-orders-list-columns.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=10881dfc426185047001ffa45ce78ed9) Work order table columns include title, status, work type, asset, and schedule with horizontal scroll for more fields Use the column control at the right edge of the header row to show or hide columns. Scroll horizontally to view fields that do not fit on screen. ### Table columns | Column | Description | | - | - | | **Title** | Work order name as a link, with work order ID below (for example, `WO-10171`). An external-link icon opens the linked Cloud BMS device when applicable. | | **Status** | Current lifecycle status (for example, **Open**, **In progress**) | | **Work type** | Program type (for example, preventive maintenance, corrective maintenance, inspection) | | **Asset** | Asset the work applies to | | **Located in** | Building area or location hierarchy for the work | | **Priority** | Priority level from [Priority & SLA](/products/assetops/portfolio/priority-sla) | | **Schedule** | Source schedule name and ID when the work order came from a schedule (for example, `SCH-02238`) | | **Tasks** | Task count or summary for work on the order | | **Deficiency** | Linked deficiency or inspection finding when applicable | | **SLA status** | SLA state (for example, on track, warning, breached) | | **Created date** | Date the work order was created | | **Start date & time** | Scheduled or actual start | | **Due date & time** | Target completion date and time | | **Logged time** | Total time logged on the [logged time](/products/assetops/work-orders/work-orders-overview#logged-time) section of the detail page | | **Assignee** | User assigned to the work | | **Team assigned** | Team assigned to the work | | **Category & issue** | [Category](/products/assetops/resources/categories) and issue type | | **Follow up** | Indicates whether follow-up work is required or pending | Select a **Title** link to open the [work order detail page](#work-order-detail-page). *** ## Focus mode **Focus mode** is a preset view on the work orders list. It shows work orders that require immediate attention, including: | Category | Description | | - | - | | **SLA breached** | Work orders that missed an SLA target defined in [Priority & SLA](/products/assetops/portfolio/priority-sla) | | **Warnings** | Work orders flagged with SLA or timing warnings before breach | | **High priority** | Work orders marked as high priority | Enable the **Focus mode** toggle on the work orders list to limit the table to these items. Turn the toggle off to return to the full list. Combine Focus mode with [status summary cards](#status-summary-cards) or [custom filters](#custom-filters) when you need a narrower view. *** ## Custom filters Custom filters narrow the list using field-based criteria. **1. Open the filter panel** On the work orders list, select **Filters**. **2. Select criteria** Choose one or more filters. | Filter | Description | | - | - | | **Category** | Work order category (for example, HVAC, plumbing) | | **Issue type** | Issue type within a category | | **Assign team** | Team assigned to the work order | | **Assignee** | User assigned to the work order | | **Vendor** | Vendor assigned to the work order | | **Asset** | Asset associated with the work order | | **Asset type** | Type of asset associated with the work order | | **Area** | Area associated with the work order | | **Due date** | Due date range | | **Region** | Geographic or organizational grouping (portfolio lists) | **3. Apply** Select **Apply** to update the table. > [!TIP] > > Combine status cards and custom filters for precise views. For example, filter **In progress** work in the **HVAC** category. *** ## Bulk edit work orders Update multiple work orders at once from the list at the building or [portfolio](/products/assetops/portfolio/work-orders) level. Bulk updates run as a **batch**: AssetOps processes each selected work order individually. Valid items complete even when some rows fail. Failed rows stay available to review and export with the failure reason (for example, an invalid status transition, a permission restriction, or a field restriction). When you start a batch, a popup confirms that processing started. If another bulk update is already running, the new job is queued. A badge shows whether the batch finished fully or stopped because of an interruption such as a network error. Review bulk activity for the last seven days in the building **Bulk History**. Each entry shows who triggered the update, how many items succeeded, and how many failed. Export the failure report from the history view to inspect row-level errors. The portfolio Work orders list provides the same seven-day Bulk History for batches run across buildings. ![Work Orders page with Bulk History panel listing complete and failed bulk updates for the last seven days](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-orders-bulk-history.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=a81efdde18f5e0a1e6b61c56770b2aee) Bulk History shows the last seven days of batch updates with status, counts, and export **1. Select work orders** Use row checkboxes or the header checkbox to select work orders. **Edit** and **Delete** appear in the toolbar. **2. Open bulk edit** Select **Edit** to open the **Edit Work Orders** modal. ![Edit Work Orders dialog with checkboxes for Status, Due Date and Time, Priority, Category, Assignee, Team Assigned, Start Date and Time, Vendor, and Estimated Time](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-orders-bulk-progress.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=66107c71c5922aeb4bc5c44d08a887c4) Edit Work Orders applies only the fields you check to every selected row **3. Choose fields and save** Enable the checkbox for each field you want to change, enter values, then select **Update Work Orders**. The batch applies checked fields to each selected work order that passes validation. **4. Review results** Confirm the batch status in the progress popup. Open the seven-day **Bulk History** to export failed items and read failure reasons. > [!WARNING] > > Bulk **Delete** permanently removes selected work orders and cannot be undone. Review your selection before you delete. **Status** `Dropdown` Lifecycle status for selected work orders. Supports bulk completion when the status transition is valid. **Due date** `Date` Target due date and time for selected work orders. **Priority** `Dropdown` Priority level for selected work orders. **Assignee** `Dropdown` User assigned to the selected work orders. **Team assigned** `Dropdown` Team assigned to the selected work orders. **Completion date** `Date` Completion date for selected work orders. Use when completing work in bulk, including HSSE workflows. **Enter status note** `Field` Optional note recorded with a status change. *** ## Create a work order Create corrective and other generic work orders for **assets** or **areas**. [Routing and dispatch](/products/assetops/resources/routing-dispatch) can assign teams automatically when you select a category and issue type. **1. Select + Create work order** On the work orders list, select **+ Create work order**. **2. Configure general details** Complete required fields. ![Create Work Order form with Title, Work Type Corrective Maintenance, Asset, Area, Category, Issue Type, Priority, Description, and Attachments upload](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-create-general.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=7dcdd93f1210b5e8a990a2079dde4bc7) Create work order form with title, work type, asset, category, priority, and description **Title** `Field` *required* Work order name. **Work type** `Dropdown` *required* Program type (for example, corrective maintenance). **Asset** `Dropdown` Asset the work applies to. Leave blank to target an area only. **Area** `Dropdown` Building area for the work. **Category** `Dropdown` *required* [Category](/products/assetops/resources/categories) for the work. **Issue type** `Dropdown` *required* Issue type within the category. **Priority** `Dropdown` *required* Priority level for SLA tracking. **Description** `Field` Rich text description with formatting options. **Attachments** `Field` Upload supporting files. > [!WARNING] > > If you select an asset, the area is assigned automatically. To create work for an area only, leave **Asset** blank. **3. Configure assignment and timeline** Set assignment and dates. ![Create Work Order assignment section with Assign Team, Assignee, Vendor, Start Date and Time, Due Date and Time, and Estimated Time hours and minutes](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-create-assignment.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=9b865bf9b3c49b8b37e62f65643e664f) Assign team, assignee, vendor, start and due dates, and estimated time **Assign team** `Dropdown` Team for the work order. Routing rules may prefill this field. **Assignee** `Dropdown` One or more users assigned to the work. **Vendor** `Dropdown` External vendor for the work. **Start date & time** `Date` *required* When work is scheduled to start. **Due date & time** `Date` Target completion date and time. **Estimated time** `Field` Planned duration in hours and minutes. **4. Save** Select **Save** to create the work order. > [!NOTE] > > When you create work orders from the [portfolio level](/products/assetops/portfolio/work-orders), you must select the target building manually. The form fields match the building-level flow. *** ## Work order detail page Select a work order **Title** from the building list to open its detail page. From the [portfolio work orders](/products/assetops/portfolio/work-orders) list or the [KODE OS Work orders](/products/kode-os/assetops/work-orders) module, select the **Title** link or the external-link icon beside the title to open the same detail page in building context. The header shows the work order name, ID badge (for example, `WO-10203`), and actions for comments and more options. Three tabs organize the page: | Tab | Purpose | | - | - | | **Details** | General information, task checklist, and logged time | | **Attachments** | Files linked to the work order | | **Follow-ups** | Related and external follow-up work orders | ### Header actions #### Comments Select the comment icon in the header to open the **Comments** panel. A badge shows how many comments exist on the work order. The panel lists comments in chronological order. Each entry shows the author, date, and message text. The system can add automated comments when status changes occur (for example, when a task moves to **Not applicable** and the work order status updates to **In progress**). To add a comment: 1. Enter text in **Add comment**. 2. Use the formatting toolbar for bold, italic, underline, links, and lists as needed. 3. Select **Comment** to post. Close the panel to return to the work order detail view. #### More actions Open the vertical ellipsis menu in the header for additional actions. | Action | Description | | - | - | | **Status history** | Timeline of status changes for this work order | | **Schedule run history** | Work orders generated from the linked schedule run (when applicable) | | **Delete** | Remove the work order | ##### Status history The **Status history** modal lists changes from newest to oldest. The current status is marked **Current**. Each entry includes: * **Status** name (for example, **Open**, **In progress**) * **Date and time** of the change * **User** who made the change, when applicable * **Note** explaining the change, including automated notes when a task status triggers a work order status update Select **Close** to return to the work order page. ##### Schedule run history For work orders created from a schedule, **Schedule run history** lists related work orders from the same schedule run. | Column | Description | | - | - | | **Number** | Work order ID (for example, `WO-04385`) | | **Status** | Current status of that work order | | **Start date & time** | Start date and time for the run | | **Due date & time** | Due date and time for the run | Use **Search** to find entries. Select the external-link icon on a row to open that work order. Select **Close** when finished. ### Details tab ![Work order Details tab for WO-10203 showing Completed status, start due and completion dates, Schedule and Log link, Asset link, and Tasks section with 6 of 6 completed progress bar](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-details.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=fdc5f8e87db24f340b6fcc89c43f54ed) Work order detail page with Details tab, general information, schedule log and asset links, and task progress #### General information Select the icon to edit general fields. | Field | Description | | - | - | | **Status** | Lifecycle status (for example, **Open**, **In progress**, **Completed**) | | **Start date & time** | When work is scheduled or started | | **Due date & time** | Target completion date and time | | **Completion date & time** | When the work order was completed | | **Work type** | Program type (for example, preventive maintenance, corrective maintenance) | | **Assignee** | User assigned to the work | | **Team assigned** | Team assigned to the work | | **Estimated time** | Planned duration for the work order | | **Schedule and log** | Link to the source [schedule](/products/assetops/schedules/schedules-overview#schedule-detail-page) log when the work order came from a schedule | | **Asset** | Link to the linked [asset](/products/assetops/assets/assets) record | | **Located in** | Building area for the work | | **Vendor** | Assigned vendor | | **Created by** | User who created the work order | | **Created at** | Creation date | #### Tasks The **Tasks** section lists checklist items from [task templates](/products/assetops/resources/task-templates) or custom tasks. A progress bar and counter show how many tasks are complete (for example, `6/6 Completed`). ![Work order Tasks section with checklist items, To Do status dropdowns, and View Description buttons](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-tasks.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=633818344f8c3b314a3cce75e7a6fc02) Task checklist with status dropdowns and view description actions * Select **Update multiple** to change status and compliance for several tasks at once * Use each task **Status** dropdown to set **To do**, **Done**, or **Not applicable** * Select **View description** or **View attachments** for task-level details ##### Set task to done When you mark a task **Done**, complete the compliance form. ![Set Task to Done modal with Compliant No selected, Corrective Action Taken Yes, and Note required validation](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-task-done.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=baf8d4e35fd12309793358d3d061741d) Set Task to Done modal with Compliant, Corrective action taken, and required Note | Field | Description | | - | - | | **Compliant** | Whether the item inspected meets requirements (**Yes** or **No**) | | **Corrective action taken** | Whether corrective work was performed when not compliant | | **Note** | Required notes about the result | ##### Set task to not applicable ![Set Task to Not Applicable modal with required Note field](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-task-not-applicable.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=bc08dc09e4c6faf17126519162b4a628) Set Task to Not Applicable requires a note Enter a required **Note** explaining why the task does not apply, then select **Save**. ##### Update multiple tasks ![Update Multiple Tasks page with Mark All as Done and Compliant and per-task Done status and compliance fields](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-update-multiple-tasks.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=acfe0cd36dee4be63c6ccab6a8e4137c) Update Multiple Tasks bulk-updates status, compliance, and notes Select **Update multiple** from the **Tasks** section. For each task, set **Status**, **Compliant**, **Corrective action taken** (when required), and **Note**. Use **Mark all as done and compliant** for a quick pass, **Reset all** to clear changes, or **Save changes** to apply. #### Logged time The **Logged time** section tracks hours spent on the work order. When no time is recorded, the section shows: * **No time logged yet** * *Start tracking your work hours to monitor progress.* Start a timer or add time entries from this section to log work against the order. Logged time rolls up to the **Logged time** column on the [work order list](#table-columns) and supports labor reporting on the [building dashboard](/products/assetops/building/dashboard). ### Attachments tab ![Work order Attachments tab with Upload button and attachment card showing date uploader and filename](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-attachments.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=e33c33b4f7aee26e53186bc61a10d4e5) Attachments tab with Upload and file cards * Select **Upload** to add files * Each card shows upload date, uploader, and file name * Use the row menu for file actions ### Follow-ups tab ![Work order Follow-ups tab with follow-up cards showing title WO ID status and Created At plus External Follow-ups section](https://mintcdn.com/kodelabs/E_jpUki-mggVLzq3/images/assetops/assetops-building-work-order-follow-ups.png?fit=max\&auto=format\&n=E_jpUki-mggVLzq3\&q=85\&s=23a3b95d86b79ecfb61089663d039099) Follow-ups tab lists internal and external follow-up work orders **Follow-ups** shows child work orders that continue work from the parent order. Select **+ Create** to add a follow-up. Each card shows title, work order ID, **Status**, **Created by**, and **Created at**. **External follow-ups** lists follow-up work pushed to external systems (for example, a CMMS), with statuses such as **Sent**. > [!NOTE] > > Follow-up work orders inherit the same asset or area as the parent work order when the parent was created for a specific target. *** ## Related modules > [card] [Schedules](/products/assetops/schedules/schedules-overview) > > View schedules that generate preventive and inspection work orders. > [card] [Assets](/products/assetops/assets/assets) > > Open assets linked to work orders. > [card] [Categories](/products/assetops/resources/categories) > > Configure categories and issue types for corrective work. > [card] [Teams](/products/assetops/resources/teams) > > Assign teams to work orders and schedules. > [card] [Work order fields](/products/assetops/reference/work-order-fields) > > Look up statuses, columns, and field definitions in one place. # Collections Source: https://docs.kodelabs.com/products/building-bi/collections Organize, publish, and manage Building BI dashboard collections to share curated dashboard sets with specific roles. Collections organize and publish Building BI dashboards for users and roles. A dashboard must belong to a collection and be published before it is visible beyond its collaborators. > [!NOTE] > > For how collections control visibility, support multiple audiences, and relate to permissions, see [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ![Collections and Dashboards page showing Favorites and Dashboard Collection sections in the left navigation, three collection cards with Published and Unpublished badges in the main area, and the My Dashboards table listing dashboards with Name, Description, Owners, Date Created, and Last Updated columns](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-collections-dashboards-page.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2b839cf8c817d4ad68e202e5e2f2991e) The Collections and Dashboards page showing collection cards, left navigation, and the My Dashboards table ## Default landing behavior The first dashboard in the first collection a user has access to automatically becomes their default landing page when they open Building BI. Arrange your most critical information at the top of the first collection for each user group. > [!TIP] > > Users can override the default landing page by marking a dashboard as a favorite. Favorited dashboards appear in a pinned section at the top of the left navigation panel. ## Create a collection **1. Open the new collection form** Click `New Collection` in the upper-right corner of the Building BI view. **2. Name the collection** Click the pencil icon next to the default name and enter a descriptive title. **3. Add dashboards** Drag dashboards from the right panel and drop them into the left panel labeled `Drop dashboards here`. ![New Collection dialog showing Engineering Dashboards as the collection name with an Unpublished badge, Overrides and Operations dashboards added on the left, a Drop dashboards here zone, and a searchable list of available dashboards on the right including Lighting, Parking Occupancy, Site Summary, and others](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-new-collection-dialog.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0edd3064f622a744f0b897ae4da22ac3) The New Collection dialog with dashboards added on the left and available dashboards on the right **4. Arrange the order** Drag dashboards within the left panel to set the display order. **5. Save the collection** Click `Create` to save. The new collection remains in an `Unpublished` state until you publish it. ## Publish a collection Publishing makes a collection visible to users beyond its collaborators. **1. Open the publish menu** Click the three-dot menu on the collection and select `Publish`. **2. Choose your audience** Select `Publish to All` to make the collection available to every user, or select `Publish to Specific Roles` to restrict access. ![Publish Collection dialog stating All Roles have access on a published collection with Cancel, Publish to Specific Roles, and Publish to All buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-publish-collection-dialog.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=53dbee01574b3a27c769bbf22fc1ed74) The Publish Collection dialog with options to publish to all users or specific roles **3. Save** Click `Save` to apply the publishing configuration. > [!NOTE] > > Collections publish to roles only, not to individual users. Assign users to the appropriate roles in Launchpad to control access. To remove a collection from publication, click the three-dot menu and select `Unpublish`. ## Shared dashboards across collections A single dashboard can appear in multiple collections to serve different audiences. This does not duplicate the dashboard. Any edits made to a dashboard automatically propagate across all collections where it appears. ## Manage a collection Select the three-dot menu on a collection card to access all management actions. ![Collection card three-dot menu showing Publish, Edit Collection, Manage Viewers, Save As Template, and Delete options for the Engineering Dashboards collection](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-collection-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=0dc0946cdbebe27f32cd937fd266dec9) Collection three-dot menu showing Publish, Edit, Manage Viewers, Save As Template, and Delete options | Action | Description | | - | - | | `Publish` | Make the collection visible to all users or specific roles | | `Edit Collection` | Rename the collection, add dashboards, or remove existing ones | | `Manage Viewers` | Add or remove roles to control which teams can access the collection | | `Save As Template` | Save the collection as a reusable template with dependencies and ontology mapping | | `Delete` | Permanently remove the collection | ### Manage viewers Select `Manage Viewers` from the three-dot menu to control which roles can access the collection. By default, all roles have access. Adding specific roles restricts access to only those roles. See [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work) for how view and edit access relate. ![Manage Viewers dialog showing All roles have access to the dashboard by default message, a search bar, Add Role button, and a table with the Engineering role listed with its description and a delete icon](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-manage-viewers.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0a2b01a9693e22172078da67301bf46c) The Manage Viewers dialog showing assigned roles with search and Add Role options ## Delete a collection Select the three-dot menu on a collection and select `Delete`. Confirm the deletion when prompted. > [!WARNING] > > Deleting a collection removes it permanently. Dashboards within the collection are not deleted and remain in your `My Dashboards` table, but they lose their published visibility until added to another collection. ## Organize collections and favorites You can reorder how collections and favorites appear in the Building BI left pane. The order you set here directly controls the left navigation order for all users with access to those collections. Select the three-dot menu in the upper-right corner of Building BI to access arrangement and audit options. ![Three-dot menu in the upper-right corner showing Arrange Favorite Dashboards, Arrange Collections, and Audit Viewers options next to the New Collection button](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-collections-top-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=0ed5e329ca7a5fae9705ed26f51502fa) The top-right three-dot menu with Arrange Favorite Dashboards, Arrange Collections, and Audit Viewers options ### Arrange collections Select `Arrange Collections` to reorder how collections appear in the left navigation. Drag collections to set the display order, then select `Save`. ![Arrange Collections dialog showing Dashboard Collection and Engineering Dashboards in a list you can drag to reorder, with Close and Save buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-arrange-collections.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f93bd93d264ccb5157b896e969baaf0d) The Arrange Collections dialog with a list of collections you can drag to reorder ### Arrange favorites Select `Arrange Favorite Dashboards` to reorder your favorited dashboards in the left navigation panel. Drag dashboards to set the display order, then select `Save`. ![Arrange Favorite Dashboards dialog showing Operations Dashboard and Lighting Occupancy in a list you can drag to reorder, with Close and Save buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-arrange-favorites.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=bf036434d39a51432b16e8618a443b3a) The Arrange Favorite Dashboards dialog with a list of favorited dashboards you can drag to reorder ### Audit viewers Select `Audit Viewers` to review role assignments across your organization. Expand a role to see which collections it has access to. ![Audit Viewers dialog showing a table with Role and Access To columns, SuperAdmin expanded to show access to Dashboard Collection and Engineering Dashboards, and other roles like EnerG DEMO USER, COPT EnerG Demo, Engineering, FDD Admin each showing 1 Collection](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-audit-viewers.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=88a81f62debcf3a52bf280f1c80a5ad4) The Audit Viewers dialog showing roles and their collection access ## Collaborator access When you add a user as a collaborator on a dashboard, they receive full edit access. Collaborators can modify the dashboard content and manage other users, including adding or removing additional collaborators. > [!WARNING] > > Collaborators have the same level of access as dashboard owners. If you need to share an editable version with external users, duplicate the dashboard first and share the copy to avoid unintended changes to the original. ## My Dashboards The `My Dashboards` section lists all dashboards you have collaborator (edit) access to. This table is sorted by `Last Updated` by default, which matches the order displayed in your left navigation panel. ## Save a collection as a template Save a collection as a reusable template to deploy across multiple buildings. Select the three-dot menu on a collection and choose `Save As Template`. **1. Set template details** Enter a `Template Name` and optional `Description` for the template. Select `Save Now` to save immediately, or select `Next` to configure dependencies. ![Save as Template dialog Step 1 Template Details showing Template Name set to Engineering Dashboards, a Description field, and Cancel, Save Now, and Next buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-save-template-details.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=e2978f58ffacfbc58aabd6200e3295db) Step 1: Template Details with name and description fields **2. Set dependencies** Select which data source dependencies to validate against target buildings. Each dashboard in the collection lists its pipelines, graphs, and other dependencies. Select the dependencies that must exist at the target site for the template to work correctly. ![Save as Template dialog Step 2 Set Dependencies showing Operations and Overrides dashboard tabs with expandable dependency items including Timeseries Last Values Pivoted with 1 Pipeline, Point Metrics with 1 Pipeline and 1 Graph, and Running Minutes Metrics with graph items](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-save-template-dependencies.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=9db90a48f20f15aacd693a56bc3dea09) Step 2: Set Dependencies showing data source dependencies per dashboard **3. Configure canonicals and fields** Select the `Canonical Types` and `Ontology Fields` that the template requires. These determine which buildings are compatible when deploying the template. When you deploy the template, Building BI checks these requirements against the target building or portfolio. It flags missing canonical types or ontology fields so you can catch gaps before the collection goes live. Use this step as a QA check for site readiness. ![Save as Template dialog Step 3 Canonicals and Fields showing Canonical Types dropdown with 11 items selected and Ontology Fields dropdown with All selected](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-save-template-canonicals.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c4bae705c91f36984a9456fc80b4f67e) Step 3: Canonicals and Fields with type and field selectors **4. Review and confirm** Review the template name, description, and dependencies. Add any additional notes in the text area. Select `Save Template` to create the template, or select `Back` to modify previous steps. ![Save as Template dialog Step 4 Review and Confirm showing Template Name Engineering Dashboards, Description No description added, Dependencies 3 including Point Time Series Last Values, Running Minutes Metrics, and Updated Version, with a notes text area and Cancel and Save Template buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-save-template-review.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=a55c81516c4c12114d9866ae3694a741) Step 4: Review and Confirm showing the template summary and dependencies ## Navigation widget The navigation widget links a dashboard to another page within the same dashboard or to a different Building BI dashboard. **1. Add the widget** Open a dashboard in edit mode and drag the `Navigation` widget onto the canvas. **2. Configure the destination** Set the `Navigate to` field to one of: * **Page** -- Select a page within the current dashboard. * **Dashboard** -- Select another Building BI dashboard. **3. Save the dashboard** Save the dashboard to apply the navigation widget configuration. ## Related reading > [card] [Collections](/products/building-bi/collections) > > Control visibility and organize dashboards by audience. > [card] [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment) > > Choose independent copies or governed portfolio parity. > [card] [Template types](/products/building-bi/reference/template-types) > > Compare collection, dashboard, page, and chart templates. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboards and manage predefined versus custom views. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts, tables, and widgets. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboard configurations across multiple sites in your portfolio. # Choosing visualizations Source: https://docs.kodelabs.com/products/building-bi/concepts/choosing-visualizations Choose Building BI chart and table types based on the question, data shape, and audience. The right chart answers the viewer's question with the least effort. Start from the question and the shape of the data — comparison, trend, part-to-whole, distribution, single value, spatial — and the candidate list narrows quickly. A comparison question usually points to a bar chart. Exact cell values usually point to a table. Match the visual to the read, not to what looks dense. ![Bar chart example in Building BI comparing category values along a horizontal axis](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-chart-types-bar.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9e97806b5ce5227dbb2d01ffd94683a7) Bar chart comparing categories ## Match the question | The viewer wants to… | Data shape | Typical choices | | - | - | - | | Compare items | Categorical | [Bar](/products/building-bi/reference/chart-types#bar), [Horizontal Bar](/products/building-bi/reference/chart-types#horizontal-bar), [Polar Bar](/products/building-bi/reference/chart-types#polar-bar) | | See change over time | Time series | [Line](/products/building-bi/reference/chart-types#line), [Time Series](/products/building-bi/reference/chart-types#time-series), [Line Area](/products/building-bi/reference/chart-types#line-area), [Combo](/products/building-bi/reference/chart-types#combo) | | See when something was active | Intervals over time | [Timeline](/products/building-bi/reference/chart-types#timeline) | | See part-to-whole | Proportional | [Pie](/products/building-bi/reference/chart-types#pie), [Treemap](/products/building-bi/reference/chart-types#treemap), [Sunburst](/products/building-bi/reference/chart-types#sunburst), [Stacked Bar](/products/building-bi/reference/chart-types#stacked-bar) | | Read one key number | Single value | [Card](/products/building-bi/reference/chart-types#card), [Number](/products/building-bi/reference/chart-types#number-target), [Gauge](/products/building-bi/reference/chart-types#gauge) | | Spot distribution or outliers | Statistical | [Boxplot](/products/building-bi/reference/chart-types#boxplot), [Scatter](/products/building-bi/reference/chart-types#scatter), [Heatmap](/products/building-bi/reference/chart-types#heatmap) | | Look up exact values | Tabular | See [Table types](#table-types) | | Understand flow | Flow | [Sankey](/products/building-bi/reference/chart-types#sankey) | | See where, spatially | Spatial | [Graphics](/products/building-bi/reference/chart-types#graphics), [Picture](/products/building-bi/reference/chart-types#picture) | | Watch a live camera feed | Live video | [Camera](/products/building-bi/reference/chart-types#camera) | | Navigate or contextualize | Utility | [Slicer](/products/building-bi/reference/chart-types#slicer), [Navigation](/products/building-bi/reference/chart-types#navigation), [Text](/products/building-bi/reference/chart-types#text) | ## Table types | Choose… | When… | | - | - | | [Raw](/products/building-bi/reference/chart-types#table-raw) | Individual rows matter (audit, export, troubleshooting) | | [Aggregated](/products/building-bi/reference/chart-types#table-aggregated) | You need one summary number per group | | [Pivot](/products/building-bi/reference/chart-types#table-pivot) | You need a grid across two dimensions | A pivot table folds a hierarchy down the rows and spreads a dimension across the columns — useful when exact values and a two-way breakdown both matter. ![All Down Devices pivot-style table grouping devices under Water Meter and VAV, with device name links and Floor values](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-pivot-table.gif?s=8def9d15d3f87f3c6289e8938d4b97ee) Pivot table with expandable device hierarchy ## Top N vs scrolling | Choose Top N when… | Choose scrolling when… | | - | - | | Extremes are the message | Viewers may need items past the first screen | | The dashboard is glance-only (for example, a wall display) | The audience will interact with the chart | Label Top N cuts so viewers know data is hidden. For interactive ops dashboards, a soft top (about 20) with a scrollbar often beats a hard cut. See [Filter options](/products/building-bi/reference/filter-options#top-n-filters) and [Zoom and scroll](/products/building-bi/reference/chart-styling-options#zoom-and-scroll). ![Chart Configuration Style tab with Scroll section expanded showing X-Axis Items set to 5 and Y-Axis Items set to 5](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-style-scroll.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=163a1052e9eea33c07a734397f6c096d) Scroll settings limit how many axis items show before scrolling ## Audience and consistency * A chart should be valuable before you add drill-through or cross-filtering. See [Drill-through filters](/products/building-bi/concepts/drill-through-filters). * Match the visual to the audience. An operator on a wall display needs a different chart than an analyst exploring data. See [Philosophy](/products/building-bi/concepts/philosophy). * When two types both fit, prefer the one your dashboards already use for that question. Quiz You are building a wall display that should highlight only the worst-performing zones at a glance. Analysts on a separate interactive ops dashboard may need to scroll past the first screen. How should you treat Top N? ## Next steps > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup fields for every widget type. > [card] [Widget customization](/products/building-bi/widget-customization) > > Style widgets and apply defaults. # Dashboard performance Source: https://docs.kodelabs.com/products/building-bi/concepts/dashboard-performance Improve Building BI dashboard load time by reducing query frequency, source cost, and rendering load. A slow dashboard is almost always doing too much querying. Performance comes from sending fewer, cheaper queries. > [!NOTE] > > Refresh less often than feels natural, split heavy dashboards across tabs, prefer pre-processed data sources, and keep virtual tables optimized. Optimization is a design discipline, not a setting you flip at the end. Every widget on a dashboard issues queries to a database. Load time is the sum of that querying. Smart decisions while building can save you time in the long run of development. ## What drives load time | Factor | What drives cost | Lever | | - | - | - | | Refresh frequency | Each chart re-queries on its Data Refresh Interval | Choose the longest interval you can tolerate | | Query volume per page | Many charts mean many simultaneous queries | Split work across **tabs** so only the active page queries | | Source weight | Raw history over long ranges is expensive | Prefer Last Value or reduced-frequency sources | | Virtual table health | A view runs every time you use it | Keep virtual tables optimized | | Calculated fields | Calculated columns and metrics cannot use window functions or aggregations of aggregations | Put that logic in a virtual table instead | | Clutter | Extra widgets cost reads and attention | Fewer, well-chosen widgets — see [Styling best practices](/products/building-bi/widget-customization#styling-best-practices) | Practical defaults: * Live operational data may warrant a short refresh. Historical trends are often fine hourly or daily. * Shared links and scheduled reports have their own refresh rates — keep them as infrequent as the data allows (often one hour). * Building BI surfaces a "Not Optimized" status on virtual sources and can suggest fixes. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). Splitting a dashboard across pages is one of the highest-leverage levers. Only the active page queries. ![Dashboard page tabs for Overview, Device Details, Floor Plans, and Page 4, with a plus control to add another page](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-add-tab.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=dec3a854da642510507c10f6adf288f9) Dashboard pages split work so only the active tab queries ## Before you publish 1. Set each chart's Data Refresh Interval to the longest acceptable value. 2. Move secondary views onto additional pages instead of one dense page. 3. Prefer Last Value or pre-aggregated sources over long-range Real-Time where current state is enough. See [Key data sources](/products/building-bi/data-sources#key-data-sources). 4. Resolve "Not Optimized" virtual sources. 5. Remove decorative or unused widgets before publish. ## Speed costs freshness and detail Longer refresh intervals mean slightly staler data. Tabs mean a click to reach the second view. Pre-aggregated sources mean less granular drill-down. Match those trades to how fresh and detailed the data must be for that audience. * Operational alerting can genuinely need frequent refresh. Do not blanket-apply long intervals. * Optimizing a shared virtual source affects every dashboard using it. Validate before saving — changes are global. * Some slowness originates upstream (integration latency, site data volume). Dashboard tuning cannot fix that. ## Next steps > [card] [Optimize virtual sources](/products/building-bi/data-sources#optimize-virtual-data-sources) > > Fix virtual table performance in Data Sources. > [card] [Database types](/products/building-bi/data-sources#database-types) > > Understand engine limits that force work upstream. # Draft mode and version history Source: https://docs.kodelabs.com/products/building-bi/concepts/draft-mode-version-history Learn how drafts, publishing, and version history let you edit Building BI dashboards without risking the live view. Draft mode and version history keep dashboard edits safe. Drafts let you change a dashboard privately. Version history stores saved states so you can preview, rename, restore, or publish an earlier version. Viewers keep seeing the last published dashboard until you publish. That separation is what makes experimentation safe. ## Draft mode A draft is a private workspace layered over the live dashboard. Each dashboard has one active draft. Selecting `Edit Dashboard` opens that draft. You can save the draft repeatedly without changing what viewers see. When the work is ready, select `Publish` to push it live. In edit mode, use `Save as Draft` next to `Publish` in the top right. Confirm in the dialog to keep the changes private. ![Operation Dashboard in edit mode showing Save as Draft next to Publish, then the Draft dashboard confirmation dialog with Not yet and Yes, save draft](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-save-as-draft.gif?s=26ac52155b2e4634f0b83332d8f72dbf) Selecting Save as Draft and confirming to keep changes private Drafts belong to the editor. Other users continue to see the published version until you publish. Only one draft version can exist at a time. ## Open version history Version history is the timeline of saved dashboard states. Each entry includes a date, author, and optional name. Open the three-dot menu on the dashboard and select `Version history`. History opens in a new tab. ![Opening a draft dashboard, selecting Version history from the three-dot menu, and loading Version History in a new browser tab](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-history-open.gif?s=e9b39ebd97f678f30651db232fa8048e) Opening Version history from the dashboard three-dot menu You can also open version history from the `Published` / `Draft` status dropdown next to the dashboard name. ## Browse and rename versions The version history view shows a read-only preview of the selected version on the left. The timeline sits on the right. Use the list to move between versions. Status labels mark the current published version, earlier published versions, and saved drafts. Turn on `Show named and published versions` to focus the list. Select the pencil icon on an entry to rename it. Clearing a custom name returns the entry to its timestamp label. ![Operation Dashboard version history with Cancel and Restore as Draft actions, dashboard preview on the left, and a Version history panel listing Published and Previously Published entries with pencil icons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-history.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=9b8ceaaad33e1b5174259e89d9b4cdcf) Version history with a dashboard preview and a timeline of published versions ## Restore or publish an earlier version Select a version in the timeline to preview it. When a previous version is selected, you can: * **Restore as Draft** — copy that version into a new private draft without changing the live dashboard * **Publish** — make that version live immediately ![Version history header showing Cancel, Restore as Draft, and Publish buttons next to the Version history panel](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-restore.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=58eaf875379243fc4799a7ee4836e54c) Restore as Draft and Publish actions for a selected previous version Restoring as a draft does not overwrite the published dashboard. Publishing the restored draft (or publishing directly from history) adds a new entry to the timeline. Building BI keeps up to 20 published versions that you can restore. Neither collaborators nor owners can delete a version. Both roles can view history, edit the draft, publish, and restore. For how edit access is granted, see [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ## Next steps > [card] [Dashboards](/products/building-bi/dashboards#version-history) > > Follow the step-by-step draft, publish, and restore workflows. > [card] [Permissions](/products/building-bi/concepts/how-permissions-work) > > Learn who can edit, publish, and restore dashboards. # Drill-through filters Source: https://docs.kodelabs.com/products/building-bi/concepts/drill-through-filters Use drill-through to jump from a summary chart to a detail page or dashboard that opens already filtered to the selection. Drill-through lets a viewer right-click a data point and jump to a more detailed page or dashboard that opens **pre-filtered** to that selection. > [!NOTE] > > It turns a high-level chart into a doorway: select West region on a portfolio bar and land on a building-level page already filtered to West. It is not the same as drill-down, which expands a hierarchy inside one chart. Analysts move between altitudes — portfolio overview, then a building, then a device — and usually rebuild the same filter by hand at each step. Drill-through collapses that into one action and carries the context with you. ## Drill-through is not drill-down * **Drill-down** stays inside one chart and expands configured hierarchy layers (for example, region → building → floor). Same widget, more detail. * **Drill-through** navigates to a different page or dashboard and filters its widgets by the point you selected. Different view, same context. A treemap with nested hierarchy levels is a common drill-down pattern: select a block to expand into the next layer inside the same chart. ![Treemap titled Down Devices with nested colored blocks for floors, each showing a downward triangle that indicates you can expand into a deeper hierarchy level](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-treemap.gif?s=c23c4f0b9048dd18c87b10868160adea) Treemap drill-down expands hierarchy inside one chart A [Tree](/products/building-bi/reference/chart-types#tree) chart shows the same nesting as branches. Both stay in one widget. Drill-through leaves the widget and opens another view. ![Tree chart with a root node branching to Parking Level nodes, each branching further into device types such as Gas Detection, Fan, FCU, and Water Meter](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-tree.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=c13af120d4131a5fed2db901f30b8e43) Tree chart showing area and device-type nesting For drill-down setup fields, see [Chart types](/products/building-bi/reference/chart-types). ## A cross-filter that travels When you right-click a data point, Building BI reads the column behind it (for example, `region = West`). If that column is registered as a drill-through column on a target, navigation options appear. Choosing one builds a normal `EQUALS` or `IN` filter from your selection and applies it to the target's widgets. Eligibility matches cross-filtering, so a metrics-only chart cannot be a source. | Target | What happens | | - | - | | **Page** (same dashboard) | Navigates to another page; the drill-through filter applies to its widgets. | | **Dashboard** (different dashboard) | Opens the target in a new tab; the filter is applied, then discarded. | Rules: * Enable drill-through on both the source and the target dashboard. * A target declares which columns can be drilled into. The selection is not saved on the target — it behaves like a one-time cross-filter. * An optional **Keep all filters** toggle decides whether the source's other active filters travel with the drill-through value, or only the selected value. * Allowed directions: Portfolio → Building, and Building → dashboards within the same building. Building → Portfolio and Building → another building are not allowed. See [Filter options](/products/building-bi/reference/filter-options) and [Filter scopes](/products/building-bi/reference/filter-options#filter-scope-hierarchy). ## When drill-through fits | Use drill-through when… | Prefer something else when… | | - | - | | Viewers move from summary to detail often | A [navigation widget](/products/building-bi/reference/chart-types) jump without a carried filter is enough | | You can enable both source and target | The journey must work on shared links or mobile (drill-through does not) | | Direction stays within allowed paths | You need Building → Portfolio or cross-building lateral jumps | Treating the filter as one-time and unsaved keeps targets clean. The cost is that the target does not remember where you came from. Directional limits keep navigation predictable — some cross-building journeys must go back up through the portfolio. * Drill-through does not work on shared links or on mobile. * A target that has not opted in will not appear as an option. * Refreshing or re-opening the target outside the drill-through flow will not reproduce the carried filter. Quiz On a portfolio bar chart, an analyst wants to right-click West and open a building-level dashboard that is already filtered to West. Executives also need a path that works on a shared link. What's the best design? ## Next steps > [card] [Dashboard filters](/products/building-bi/dashboards#dashboard-filters) > > Configure filters and related interactions on a dashboard. > [card] [Filter scopes](/products/building-bi/reference/filter-options#filter-scope-hierarchy) > > Control which widgets a carried filter touches on arrival. # How filtering works Source: https://docs.kodelabs.com/products/building-bi/concepts/how-filtering-works Understand how Building BI filters combine into one query and why dropdown options can disappear. Filters in Building BI look like UI controls but are really **SQL written for you**. Each filter narrows the query sent to the database. Because filters compose into one query, they constrain each other: a value can vanish from one filter's dropdown simply because another filter has already excluded it from the data. Filters are set at the chart level and shape what a chart shows. Each one modifies the SQL statement that fetches data. See [Filter options](/products/building-bi/reference/filter-options). ## Filters compose into one query Think of a chart's filters as clauses in a single query. Add a filter and you add a condition. The database returns only rows that satisfy all of them together. That is why **filters are interdependent**. Options in one filter's dropdown come from the currently filtered dataset. If filter A has restricted the data to Building X, filter B's device dropdown can only offer devices in Building X. The missing option is not gone — another filter excluded it. The same single-query model explains the broader toolkit: * **Slicers** hold a filter and apply it across a defined **scope** of other widgets — one control, many charts. * **Cross-filters** turn a click on a chart segment into a temporary condition on the rest of the page. * **Multi-widget filters work across data sources** when underlying column names match exactly. Display labels do not matter. Prefer ID columns when names can drift. See [Polling and data structure](/products/building-bi/data-sources#polling-and-data-structure). A slicer is the on-canvas control viewers use most often. Changing its selection injects the same condition into every widget in scope. ![Slicer widget opening a date picker with quick select options such as Last 7 Days, dual-month calendars, and Clear and Apply buttons, then showing an applied date range](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-slicer.gif?s=6387132fcc65f7964eba2ca0843b9306) Date slicer with quick ranges and a calendar picker Use `Edit Scope` when one widget must stay fixed while the rest of the page responds to a filter. See [Filter scopes](/products/building-bi/reference/filter-options#filter-scope-hierarchy). ![Edit Scope interface mapping which charts and filters a selected filter influences on the dashboard](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-filter-options-edit-scope.gif?s=aadd2d95ca5039a4052026bcc8499273) Edit Scope controls which widgets a filter affects ## When a dropdown is missing a value Interdependence keeps choices coherent — you are never offered a combination that returns nothing. The cost is the occasional "where did my option go?" moment, which feels like a bug but is the system protecting you from empty results. If a value is missing: 1. Remove other filters to expose the full dataset. 2. Or bypass the dropdown with a `Contains` filter and type the value directly. See [Filter options](/products/building-bi/reference/filter-options). * In chart configuration, interdependent filters do not show which other filter hid an option. Diagnosing that case is elimination. * On the widget itself, hover the filter indicator in the top-right corner. A popup lists the filters that currently affect that widget. * Cross-source filtering fails silently when column names do not match exactly. * Every filter is also a performance lever — narrower queries are cheaper, but elaborate filtering on huge ranges still costs. See [Dashboard performance](/products/building-bi/concepts/dashboard-performance). Quiz On a Building BI chart, you filter to Building X. The device dropdown no longer lists a device you know exists in another building. What is going on? ## Next steps > [card] [Filter options](/products/building-bi/reference/filter-options) > > Look up operators, scopes, and configuration fields. > [card] [Drill-through filters](/products/building-bi/concepts/drill-through-filters) > > Jump from a summary chart to a detail view already filtered. # How Building BI permissions work Source: https://docs.kodelabs.com/products/building-bi/concepts/how-permissions-work Understand how view access, edit access, collaborators, and collections control who can use Building BI dashboards. Building BI separates **view** access from **edit** access. You need the right permissions to view dashboards. To edit a dashboard, you must be added as a collaborator. Access is either role-based or user-based. ## Two kinds of access | Access | Who gets it | How you grant it | | - | - | - | | View | Roles | Publish a [collection](/products/building-bi/collections) to all roles or a subset of roles | | Edit | Individual users | Add them as collaborators on the dashboard | A dashboard that is never published in a collection stays visible only to its owner and collaborators. Collections are how dashboards become visible to the wider organization. For how collections publish visibility by role, see [Collections](/products/building-bi/collections). ## Platform roles live in Launchpad KODE OS roles and product permissions are configured in Launchpad, not inside Building BI. That includes platform permissions such as `Manage Collections`, which is required to create and manage collections. Assign roles and product permissions in [KODE OS apps and roles](/products/launchpad/client-organizations/apps). For the Building BI permission list, see the [Launchpad permissions reference](/products/launchpad/client-organizations/apps/permissions-reference#building-bi). ## Where you manage dashboard access Use the `Collections and Dashboards` page in Building BI to manage how dashboards are shared. From there you can: * Publish collections and change which roles can view them * Open a dashboard's `Permissions` dialog to manage collaborators ## Grant edit access with collaborators Collaborators are individual users with read and edit access to a specific dashboard. **1. Open Collections and Dashboards** In Building BI, open the `Collections and Dashboards` page. **2. Open dashboard permissions** Open the three-dot (`…`) menu on the dashboard row and select `Permissions`. **3. Add collaborators** Open the `Collaborators` tab. Select `Add Users`, choose the people who should edit the dashboard, then save. ![Collections and Dashboards page showing the My Dashboards three-dot menu opened to Permissions, then the Collaborators tab with Add Users to grant edit access](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-permissions-add-collaborator.gif?s=6f84c3fd641f6d067a14a5262cdb7d48) Adding a collaborator from the dashboard Permissions dialog The person who created the dashboard appears as `Owner` on the collaborators list. The owner always has collaborator access. You cannot remove the owner's collaborator access or change who the owner is. Collaborators can also edit the collaborators list. > [!NOTE] > > The `Users` and `Roles` tabs in the `Permissions` dialog are legacy. Collection publishing supersedes them for view access. Use `Collaborators` for edit access and collections for view access. ## Grant view access with collections View access is role-based and managed through collections. A [collection](/products/building-bi/collections) is a published set of dashboards shared with roles in your organization. When you publish a collection, you can publish to all roles or to a subset of roles. You can later change which roles can view the collection with `Manage Viewers`. Only users with the `Manage Collections` platform permission can create collections. That permission is managed in Launchpad. **1. Open the collection menu** On the `Collections and Dashboards` page, open the three-dot (`…`) menu on the collection card. **2. Open Manage Viewers** Select `Manage Viewers` to see which roles can view the collection. **3. Add roles** Select `Add Role`, choose the roles that should view the collection, then save. ![Collections and Dashboards page showing a collection three-dot menu opened to Manage Viewers, then Add Role to grant view access by role](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-permissions-manage-viewers.gif?s=7c5e530bc612b28d4d5a5afe51a27e5f) Adding a role as a collection viewer For full publish and collection management steps, see [Collections](/products/building-bi/collections). ## Next steps > [card] [Collections](/products/building-bi/collections) > > Publish collections and manage which roles can view them. > [card] [Dashboards](/products/building-bi/dashboards#dashboard-permissions) > > Add collaborators from the dashboard permissions dialog. > [card] [KODE OS roles](/products/launchpad/client-organizations/apps) > > Configure roles and product permissions in Launchpad. > [card] [Collections](/products/building-bi/collections) > > Publish collections to control dashboard visibility by role. # The philosophy of Building BI Source: https://docs.kodelabs.com/products/building-bi/concepts/philosophy Learn how Building BI collapses KODE OS modules into a single pane of glass tailored to each user's workflow. The core idea is the single pane of glass: *one **dashboard to rule them all, one dashboard to find them; one dashboard to bring together FTT/FDD, Graphics, BDH transformations, AssetOps insights, energy data, and custom sensor metrics**—and in the module bind them.* 🧙 Users gain a unified view of their building operations without having to module-hop. > [!NOTE] > > The guiding question is never "what data can I show?" but "what does this user need to do their job?" KODE OS already has dedicated modules — FDD, FTT, Graphics, Energy, AssetOps. Building BI exists because answering one operational question often meant hopping between those modules and holding the pieces together in your head. A building intelligence tool consolidates data, metrics, and workflows into one customizable dashboard. There is also a legacy **Dashboard** module that predates Building BI and is being phased out. If you find yourself in that older module, you are almost certainly in the wrong tool. A strong Building BI dashboard is a focused portal: a few widgets that answer one workflow, not every metric the building can produce. ![Completed tutorial dashboard with summary cards, charts, and a device table arranged for a down-devices workflow](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-final-layout.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0d9f62282095323088f399399caaeaff) Example dashboard built around one operational workflow ## A portal for a workflow, not a data catalogue That single pane of glass can pull from across KODE OS — including [FDD](/products/fdd/overview), [FTT](/products/ftt/overview), Graphics, [AssetOps](/products/assetops/quickstart/overview), energy data, and custom sensor metrics. "Can combine everything" is not "should." Treat Building BI as a **portal tailored to a workflow**: * A dashboard serves an audience, not a data catalogue. Design for how a specific person works day to day. * For executives and analysts, the dashboard may be most of their building-information solution and can justify a comprehensive build-out. * For building operators, the bigger risk is overload. Prefer one workflow per dashboard: surface issues, then hand the user off to the right module to act. As you build, test whether the layout supports the natural progression of that user's daily tasks. Early on, ask a colleague what the user actually needs. ## Editorial restraint is the hard part Nothing stops you from adding another chart. The limiting skill is editorial restraint, not technical capability. The same tension shows up in [Top N vs scrolling](/products/building-bi/concepts/choosing-visualizations#top-n-vs-scrolling), drill-through, and [styling best practices](/products/building-bi/widget-customization#styling-best-practices). One giant dashboard that shows everything to everyone is what Building BI makes possible — and what good practice avoids. * Value depends on configuration quality upstream (ontology, point modeling, integrations). A single pane of glass over messy data is still messy. * "Tailor to the user" assumes you know the user. When you do not, treat early dashboards as drafts. * Some organizations restrict roles so a user only ever sees one building. Do not assume everyone can reach a portfolio-level view. See [Portfolio and building scope](/products/building-bi/overview#portfolio-and-building-scope). Quiz A building operator needs to find down devices each morning, then open Fault Detection and Diagnostics to act. Leadership also wants “everything the building can show” on one screen. What design best matches Building BI’s philosophy? ## Next steps > [card] [Building BI overview](/products/building-bi/overview) > > Return to the product overview and documentation map. > [card] [Build your first dashboard](/products/building-bi/tutorials/build-your-first-dashboard) > > Walk through creating and publishing your first dashboard. # Physical vs virtual data sources Source: https://docs.kodelabs.com/products/building-bi/concepts/physical-vs-virtual-data-sources Compare physical and virtual Building BI data sources and choose where transformations should run. A **physical** data source is real data sitting in a table from the KODE backend. A **virtual** data source is a saved SQL query — a view — layered on top of physical tables. > [!NOTE] > > Virtual sources are flexible and editable, but they compute on demand. Use virtual tables where on-demand computation helps, especially real-time reshaping. Both kinds appear in the same list and can feed a chart. The distinction is where the data lives versus where it is computed. See [Data source types](/products/building-bi/reference/data-source-types). The Data Sources page shows each source's type (Physical or Virtual) and database engine side by side. ![Data Sources page listing sources with Type column values Virtual or Physical and Database Type values such as CLICKHOUSE, POSTGRES, and BIG\_QUERY](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=801948d90bae5f886cde8e17d0161ba5) Data Sources list with Physical and Virtual types ## Physical tables store rows; virtual tables compute them * A **physical** source is a materialized table. The rows already exist. They are direct pulls from the KODE backend. Point Time Series Real-Time is the canonical example: every reading is a stored row. * A **virtual** source is a **view**: a SQL expression that runs against one or more physical tables when queried. Nothing is stored; the rows are derived each time. Point Time Series **Last Value** is a virtual view that returns the most recent reading per sensor. See [Key data sources](/products/building-bi/data-sources#key-data-sources). Physical tables are the warehouse shelves. Virtual tables are standing instructions for assembling a custom order from those shelves on request. Because a virtual table re-derives its rows on every query, cost scales with how much work the query does. Light reshaping (like last value per point) is cheap. Heavy, high-dimension aggregation is not. ## Choose physical or virtual | Prefer a physical source when… | Prefer a virtual source when… | | - | - | | Rows should already exist | You need a light, editable reshape for real-time use | | Query-time cost must stay low for heavy transforms | You are prototyping a reshape | | Historical trending needs a stable materialized result | The view is simple and stays optimized | When you hit a calculated column or metric ceiling — for example, no window functions or aggregations of aggregations — put that logic in a virtual table SQL view. See [Calculated fields](/products/building-bi/reference/calculated-fields) and [Database types](/products/building-bi/data-sources#database-types). * Virtual tables are quick to create and edit, but they recompute every time and can become slow on large datasets. * Editing a virtual source's SQL is organization-wide. It affects every dashboard in your organization that uses it. It does not change other organizations. Validate before saving. * Virtual tables can be built on ClickHouse and PostgreSQL, but not BigQuery. * A "Not Optimized" status on a virtual source is a common hidden cause of slow dashboards. See [Dashboard performance](/products/building-bi/concepts/dashboard-performance). Building BI can suggest filters to tighten a virtual source. Review suggestions before you save. They affect every dashboard in your organization that uses the source. ![Edit RTU Details dialog showing Optimize your Virtual Datasource suggestions with a filter template and source table names](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-optimize.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2154609381db4a7d3cbd2e1ac108cf4a) Optimization suggestions on a virtual data source Quiz You need a dashboard that trends a heavy, multi-dimensional aggregation over months of point history. The first prototype used a virtual data source, and the charts are already slow. What should you do next? ## Next steps > [card] [Optimize virtual sources](/products/building-bi/data-sources#optimize-virtual-data-sources) > > Fix virtual table performance in Data Sources. > [card] [Key data sources](/products/building-bi/data-sources#key-data-sources) > > See the most common physical and virtual Point Time Series pair. # Templating vs deployment Source: https://docs.kodelabs.com/products/building-bi/concepts/templating-vs-deployment Choose Building BI templating for independent starting points, or deployment when copies must stay synchronized across sites. Both copy a dashboard from one place to another, but they answer different needs. **Templating** gives you a starting point you expect to modify. **Deployment** gives you parity; the copies stay governed and in sync. > [!NOTE] > > Choose by asking whether the sites should stay identical after the copy is made. ## Independent copy vs live sync The deciding question is the relationship *after* the copy is made: * **Templating** produces an independent copy. You template a chart, page, dashboard, or whole collection, then use that template wherever you need a head start. Edit freely — there is no ongoing link to the original. See [Template types](/products/building-bi/reference/template-types). * **Deployment** produces a governed copy. The Deployment Manager pushes one dashboard to many buildings and keeps them synced: publish a new version at the source and every predefined copy updates. See [Deployment manager](/products/building-bi/deployment-manager). A template is a photocopy you are free to mark up. A deployment is a live mirror that keeps reflecting the source. Organization templates live in the Templates gallery as independent starters you apply and then edit. ![Templates page with Dashboards filter selected showing Organization Templates cards such as Comfort and Air Quality, Lighting, Operations, and Site Summary](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-org.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=af42c8b5b612730df11bddab9ea5201d) Organization dashboard templates in the Templates gallery A deployed dashboard shows a `Predefined` chip while it stays synced to the source. Customize it and that site leaves the sync track. ![Overrides dashboard showing a Predefined status chip, Customize Dashboard and Edit Dashboard buttons, KPI cards, charts, and an overridden points table](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-predefined-view.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=4a30e40e023c4cb4ed59b941867fd50f) Predefined deployed dashboard with Customize Dashboard available ## Template or deploy | Choose templating when… | Choose deployment when… | | - | - | | Copies should diverge and be edited freely | Sites must stay identical | | You need a starting point, not ongoing sync | Central publish should update every linked site | | You are sharing layouts across organizations | You are standardizing one dashboard across many buildings | These are not mutually exclusive. A common pattern is to template a variant for sites that genuinely differ, and deploy the standard version everywhere else — escaping parity deliberately rather than accumulating ad-hoc custom views. | | Templating | Deployment | | - | - | - | | Relationship to source | Independent copy | Synced (predefined) until customized | | Best for | Starting point; heavy local change expected | Identical dashboards across many sites | | Maintenance | Each copy maintained separately | Maintained centrally; propagates on publish | | Risk | Drift — copies diverge over time | Rigidity; a bad publish hits everyone | Templates can also be exported and imported across organizations (24-hour secure URL) and exist at organization or global scope. They can carry Building Data Hub pipeline dependencies so the data plumbing recreates with the layout. See [Template types](/products/building-bi/reference/template-types). * Templating is independent, so no copy benefits from later improvements to the original. * Deployment maintains parity, so a flaw published once reaches every linked site. Test before deploying. * Do not use templating to solve a visibility problem. Making a dashboard visible to roles is what collections are for. Quiz You need the same operations dashboard on 40 buildings. When the central team improves a chart and publishes, every site should update. A few lab buildings will later need their own version. What's the best approach? ## Next steps > [card] [Templates](/products/building-bi/templates) > > Create and apply templates. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboards and keep sites in sync. # Dashboards Source: https://docs.kodelabs.com/products/building-bi/dashboards Create, edit, share, and manage Building BI dashboards with interactive charts, widgets, and customizable layouts. Building BI dashboards let you visualize building data through interactive charts, tables, widgets, and live camera feeds. You can create custom layouts, share dashboards with your team, and publish them for broader access. > [!NOTE] > > For chart type fields and Style tab options, see [Chart types](/products/building-bi/reference/chart-types) and [Chart styling options](/products/building-bi/reference/chart-styling-options). For visualization selection guidance, see [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations). ## In this guide > [card] [Create and edit](#create-a-dashboard) > > Create dashboards, tabs, widgets, and filters. > [card] [Chart types](#chart-types) > > Jump to each widget type in the Chart types reference. > [card] [Collaborate and publish](#collaboration) > > Use drafts, permissions, and version history. > [card] [Share and export](#share-dashboards-and-widgets) > > Share links, export PDF files, and schedule reports. ![Collections and Dashboards page showing three collection cards at the top with a Published Dashboard Collection, an Unpublished Dashboards collection, and another Unpublished Dashboard Collection, and the My Dashboards table below listing dashboards with Name, Description, Owners, Date Created, and Last Updated columns](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-overview.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=df109388384aa00b6a4554ec85295449) Collections and Dashboards page showing collections at the top and the My Dashboards table below ## Create a dashboard **1. Open Building BI** Navigate to `Building BI` > `Collections & Dashboards`. **2. Start a new dashboard** Select `+ New Dashboard` in the `My Dashboards` section. **3. Configure dashboard details** Enter a `Dashboard Title`, select a [`Timezone`](/products/building-bi/reference/timezone-configuration), and add an optional `Description`. ![Add Dashboard dialog showing Dashboard Title set to Operations Dashboard, Timezone set to America/Detroit minus 04:00, a Description field, and Cancel and Create buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-add.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8359b44323fc375fd78a418f444919c7) Add Dashboard dialog with title, timezone, and description fields **4. Save the dashboard** Select `Create` to save your new dashboard. Click on the dashboard you have created. The dashboard opens with an empty canvas. ![Operations Dashboard in Published state showing Page 1 tab with a Page has no widgets message and an Edit Dashboard button](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-empty.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=b7f3d73911e986031bb15698d9224638) A newly created dashboard with an empty canvas and an Edit Dashboard button ## Collaboration Only one person can edit a dashboard at a time. If multiple users edit simultaneously, the last save overwrites earlier changes. Building BI provides a [draft and publish workflow](/products/building-bi/concepts/draft-mode-version-history) with two ways to save your work: * **Save as Draft** -- keeps your changes private. Other users continue to see the previously published version. * **Publish** -- pushes all changes live to every viewer and collaborator. Select `Save as Draft` to save a private draft. A confirmation dialog asks you to confirm before proceeding. ![Operation Dashboard in edit mode showing Save as Draft next to Publish, then the Draft dashboard confirmation dialog with Not yet and Yes, save draft](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-save-as-draft.gif?s=26ac52155b2e4634f0b83332d8f72dbf) Selecting Save as Draft and confirming to keep changes private Use the status dropdown next to the dashboard name to switch between `Published` and `Draft` views, or to open `Version History`. ![Dashboard status dropdown showing Published, Draft with a checkmark, and Version History with an external link icon](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-status-dropdown.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=d154e593a35ae30cd135b276f3699123) Status dropdown showing Published, Draft, and Version History options > [!NOTE] > > Collaborators added through `Permissions` receive full edit access, including the ability to manage other users on that dashboard. They cannot remove the original owner. > [!TIP] > > If you want an external user to edit a dashboard without granting full access to the original, duplicate the dashboard first and share the copy. ## Dashboard tabs Tabs split a dashboard into separate pages, each with its own set of widgets and data queries. Use tabs to organize analytics by topic and improve loading performance on large dashboards. To manage tabs while in edit mode: * **Add a tab** -- select the `+` icon next to the existing tab names. The new tab appears with an editable name field. * **Rename a tab** -- double-click the tab name and type the new name. * **Duplicate, delete, or save as template** -- select the three-dot menu (`...`) on the tab. ![Dashboard tab bar showing Overview, Device Details, Floor Plans tabs and a new Page 4 tab with an editable name field and the plus icon to add more tabs](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-add-tab.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=dec3a854da642510507c10f6adf288f9) Adding a new tab by selecting the + icon, with the tab name ready to edit > [!TIP] > > Split large dashboards across multiple tabs. Each tab loads its data independently, which reduces query volume and speeds up rendering. ## Add widgets and charts **1. Enter edit mode** Open the dashboard and select `Edit Dashboard`. The Chart List panel opens on the right side showing all available chart types. ![Dashboard in edit mode showing an empty canvas with a Drag and drop chart types to the page message, and the Chart List panel on the right listing Bar, Horizontal Bar, Stacked Bar, Stacked Horizontal Bar, Combo, Line, Line Area, Stacked Line, Pie, Sunburst, Multi-Row Card, Card, Number Period, and Number Target chart types with icons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-chart-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=bc3ce1c31111e4c9f039e8468aecc79b) Dashboard edit mode with the Chart List panel showing available chart types **2. Choose a chart type** Drag a chart type from the Chart List onto the canvas. The `Chart Configuration` panel opens with `Setup` and `Style` tabs. For Setup requirements by type, see [Chart types](/products/building-bi/reference/chart-types). **3. Select a data source** Choose a data source from the `Data Source` dropdown in the configuration panel. The panel shows a "Datasource required!" warning until you select one. Once selected, the available `Metrics` and `Columns` from that data source appear in the panel. ![Dashboard in edit mode showing the Chart Configuration panel with Setup and Style tabs, a Charts section with chart type icons, a Data Source dropdown showing Data Sources with a Datasource required warning in red, and X-Axis, Legend, and Y-Axis drop zones highlighted in red with Drag or add here placeholders](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-chart-setup.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=b6d67ddf5855fd7797390f7b7bbab7c8) Chart Configuration panel before selecting a data source, showing the Datasource required warning ![Dashboard in edit mode with a Zone Temperature vs Effective Setpoints combo chart, Chart Configuration panel showing Setup tab with chart type icons, Data Source set to Timeseries Last Va, X-Axis set to Area Name, and Metrics list including Total Count, One Metric, Cooling Request Pe, and Heating Request P](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-setup-tab.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2605302328da04d3cdf6cf18910db267) Chart Configuration panel after selecting a data source, showing the Setup tab with metrics list and configured axes **4. Configure data points** Search for columns and metrics using the search bar above the lists. Drag items into the `X-Axis`, `Y-Axis`, `Secondary Y-Axis`, and `Legend` fields to define what the chart displays. ![Chart Configuration panel with Data Source set to Timeseries Last Val, a search field with area typed, Columns section showing Area Id, Area Name with an info icon, Area Name duplicate, Area Level with fx, and Area Name Grouped with fx, and X-Axis set to Area Name](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-columns-search.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=37b42e3033b66ccccce7dc00f69aac9e) Searching for columns in the data source and dragging them into axis fields ![Dashboard showing a configured Zone Temperature vs Effective Setpoints combo chart with bar and line series, Chart Configuration panel showing Setup tab with X-Axis set to Area Name, Y-Axis set to Zone Temp, Secondary Y-Axis set to Cooling Stpt and Heating Stpt, and Metrics list on the right](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-chart-configured.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=209bff7b9e20ae746713aa21dea566b2) A fully configured combo chart with X-Axis, Y-Axis, and Secondary Y-Axis populated **5. Customize appearance** Switch to the `Style` tab to configure visual settings. Set the chart title, colors, and size. Reposition widgets on the canvas using drag-and-drop. For Style field options, see [Chart styling options](/products/building-bi/reference/chart-styling-options). ![Chart Configuration Style tab showing a left sidebar with General, X-Axis, Y-Axis, Secondary Y-Axis, Dynamic Units, Bar Configuration, Legends, Chart Tooltips, Bar Data Labels, Line Data Labels, Bar Colors, Line Styles, Line Colors, and Markers sections with eye icons, and the Title section expanded showing a title field set to Area name with Margin, Font set to Manro 12 px with bold italic and color options, and a Values section with Font and Margin settings](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-style-tab.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=1d99ef44a48ac525af5fe2a3070d3a3a) Style tab showing General, axis, legend, tooltip, data label, and color configuration sections **6. Save your changes** Select `Save as Draft` to keep changes private, or `Publish` to push them live. > [!TIP] > > Use the three-dot menu on any chart to duplicate or delete it. You can also select multiple widgets at once by holding Shift and clicking each widget, then apply style changes in bulk. For live camera feeds, see the [Camera widget](/products/building-bi/reference/camera-widget) reference. ## Widget setup and configuration Each widget has two configuration tabs: `Setup` and `Style`. The options available in both tabs vary depending on the chart type you select. A [Combo](/products/building-bi/reference/chart-types#combo) chart exposes X-Axis, Y-Axis, Secondary Y-Axis, and Legend fields along with bar and line style controls, while a [Card](/products/building-bi/reference/chart-types#card) widget only requires a single metric and offers title and number formatting options. Always configure the `Setup` tab first to define your data, then switch to `Style` to adjust the visual presentation. Hover over configuration fields to see inline tooltips that explain each setting. See [Configuration field tooltips](/products/building-bi/widget-customization#configuration-field-tooltips) for coverage across widget setup, filters, and time range controls. ### Setup tab The `Setup` tab controls which data the widget displays and how it is structured. Available fields from your data source are split into two categories: * **Metrics** — pre-aggregated values such as averages, sums, or counts. Click the `fx` button next to a metric name to view its underlying formula. * **Columns** — fields pulled directly from the data source. Calculated columns also display the `fx` indicator. > [!WARNING] > > You cannot edit calculated metric or calculated column formulas from the `fx` popup in the chart configuration. To modify the formula, go to the data source directly. See [Data sources](/products/building-bi/data-sources) for details. Each field displays an icon indicating its data type: | Icon | Data type | | - | - | | `#` | Number | | `A` | String | | Calendar | Date/time | | Switch | Boolean | Depending on the chart type, the `Setup` tab includes some or all of the following parameters: **X-Axis / Y-Axis** `Field` The primary dimensions for your data. Define what appears on each axis of the chart. **Legend (Breakdown)** `Field` Splits data into categories. For example, break down total energy usage by individual floors. **Filters** `Field` Restricts the data shown in the chart. Filter by time range, device name, ontology type, or any column value. **Top N** `Field` Limits the chart to the highest or lowest N values. For example, set `Top N` to `5` to show only the five highest-consuming units. **Sort Order** `Field` Organize the chart by a column's values. Click the double-arrow icon (`⇅`) next to any column to change its sort direction. Drag columns in the `Sort Order` section to set priority. **Data Refresh Interval** `Field` Controls how often the chart queries new data. Set this to the longest acceptable interval to optimize dashboard loading times. When you add a column or metric to a parameter, select the arrow (`>`) next to it to open additional options. You can rename the `Display Name`, choose an `Aggregate Function` (Average, Sum, Min, Max, Count, or Count distinct), apply breakdown dimensions, or hide the field from tooltips. ![Column options popup for Cooling Stpt showing Display Name field, Original name Cooling Setpoint, Aggregate Function radio buttons with Average selected and Sum, Min, Max, Count, Count distinct options, Apply breakdown dimensions checkbox, Hide on tooltip checkbox, and Cancel and Save buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-column-options.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=e53fa5ddbdf9ee02261817ccc40bffd1) Column options showing Display Name, Aggregate Function, and additional settings ### Style tab The `Style` tab controls visual presentation without changing the underlying data. The sections available depend on the chart type. For example, a combo chart includes separate sections for bar colors, line colors, line styles, and a secondary Y-axis, while a pie chart offers slice colors and label positioning instead. Common style sections include: * **General** -- title font, padding, background, and corner radius * **X-Axis / Y-Axis** -- axis labels, margins, font, and rotation * **Legends** -- position, font, and visibility * **Chart Tooltips** -- tooltip content and formatting * **Data Labels** -- value labels on bars, lines, or slices * **Colors** -- bar colors, line colors, or series colors depending on chart type * **Markers** -- data point markers on line charts Chart-specific sections appear only when relevant. Look up every Style field and the per-type section matrix in [Chart styling options](/products/building-bi/reference/chart-styling-options). Toggle individual style features on or off using the eye icon next to each section. ### Chart types Building BI supports more than 35 widget types. Use [Chart types](/products/building-bi/reference/chart-types) for Setup requirements per widget. Use [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) when you need selection guidance. | Category | Chart types | | - | - | | Bar and column | [Bar](/products/building-bi/reference/chart-types#bar), [Horizontal Bar](/products/building-bi/reference/chart-types#horizontal-bar), [Stacked Bar](/products/building-bi/reference/chart-types#stacked-bar), [Horizontal Stacked Bar](/products/building-bi/reference/chart-types#horizontal-stacked-bar) | | Line and area | [Line](/products/building-bi/reference/chart-types#line), [Line Area](/products/building-bi/reference/chart-types#line-area), [Stacked Line](/products/building-bi/reference/chart-types#stacked-line), [Time Series](/products/building-bi/reference/chart-types#time-series) | | Combo and comparison | [Combo](/products/building-bi/reference/chart-types#combo), [Scatter](/products/building-bi/reference/chart-types#scatter), [Advanced Scatter](/products/building-bi/reference/chart-types#advanced-scatter) | | Distribution | [Pie](/products/building-bi/reference/chart-types#pie), [Sunburst](/products/building-bi/reference/chart-types#sunburst), [Polar Bar](/products/building-bi/reference/chart-types#polar-bar), [Stacked Polar Bar](/products/building-bi/reference/chart-types#stacked-polar-bar), [Treemap](/products/building-bi/reference/chart-types#treemap) | | Statistical | [Heatmap](/products/building-bi/reference/chart-types#heatmap), [Boxplot](/products/building-bi/reference/chart-types#boxplot), [Horizontal Boxplot](/products/building-bi/reference/chart-types#horizontal-boxplot), [Sankey](/products/building-bi/reference/chart-types#sankey) | | Number and KPI | [Card](/products/building-bi/reference/chart-types#card), [Multi-row Card](/products/building-bi/reference/chart-types#multi-row-card), [Number (Period)](/products/building-bi/reference/chart-types#number-period), [Number (Target)](/products/building-bi/reference/chart-types#number-target), [Number with Trend-line](/products/building-bi/reference/chart-types#number-with-trend-line), [Gauge](/products/building-bi/reference/chart-types#gauge) | | Tables | [Table Raw](/products/building-bi/reference/chart-types#table-raw), [Table Pivot](/products/building-bi/reference/chart-types#table-pivot), [Table Aggregated](/products/building-bi/reference/chart-types#table-aggregated) | | Specialized | [Text](/products/building-bi/reference/chart-types#text), [IFrame](/products/building-bi/reference/chart-types#iframe), [Weather](/products/building-bi/reference/chart-types#weather), [Slicer](/products/building-bi/reference/chart-types#slicer), [Navigation](/products/building-bi/reference/chart-types#navigation), [Graphics](/products/building-bi/reference/chart-types#graphics), [Timeline](/products/building-bi/reference/chart-types#timeline), [Tree](/products/building-bi/reference/chart-types#tree), [Picture](/products/building-bi/reference/chart-types#picture), [Camera](/products/building-bi/reference/chart-types#camera), [Building Date Time](/products/building-bi/reference/chart-types#building-date-time) | ## Dashboard filters Dashboard filters let you apply filter criteria across all widgets at once, instead of configuring filters on each chart individually. See [filter options](/products/building-bi/reference/filter-options) for operators and scopes. Building BI supports two filter scopes: * **Dashboard-level filters** — apply to every tab in the dashboard. * **Page-level filters** — apply only to the widgets on the current tab. To add a filter, select the filter icon in the edit mode sidebar to open the Filters panel. Configure cross-filtering, drill-through filtering, and drag columns from your data source into the `Dashboard Filters`, `Page Filters`, or `Drill Through Columns` fields. ![Filters panel showing Cross-filtering enabled, Drill through filtering and Keep all filters options, Dashboard Filters with Date Time Local set to Last 365 Days, Page Filters and Drill Through Columns drop zones, and a Data Source set to Timeseries Last Va with Columns list including Connector Id, Connector Name, Building Id, Building Name, Building Region, Building Type, Building Sqft, Area Id, and Area Name](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-filters.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=cd6690765a05aa526d1477aa9ba8cdb8) Filters panel showing dashboard filters, page filters, and drill-through columns with the data source columns list Pin frequently used filters to keep them visible at the top of the dashboard. Pinned filters remain accessible outside of edit mode so viewers can adjust them. > [!NOTE] > > **Graphics** widgets on the same dashboard respond to slicers, dashboard filters, page filters, and cross-filter selections from other widgets. Marker visibility updates automatically; underlying data queries are unchanged. See [Enhanced graphic view](/products/building-bi/widget-customization#enhanced-graphic-view). > [!WARNING] > > Pinned filters are not included in PDF exports. If you export a dashboard to PDF, the exported data reflects the current filter state but the filter controls themselves do not appear in the output. ## Dashboard parameters Give a dashboard its own targets, rates, or baselines, or try a value without saving it. Declare the parameter on the [data source](/products/building-bi/data-sources#parameters) first. ### Save a dashboard value **1. Edit the dashboard** Open the dashboard in edit mode. **2. Open Parameters** In the sidebar, open `Parameters (What if Scenarios)` and select the data source. **3. Set the value** Enter a value for each parameter. The control matches the data type. Allowed values appear as a dropdown. Reset returns the parameter to the data source default. **4. Save** Select `Save as Draft` or `Publish`. Widgets that read the changed parameter refresh. Widgets on other tabs refresh when you open those tabs. Two dashboards on the same data source can store different values. ### Run a what-if In view mode, open `Parameters` in the sidebar next to `Filters`. Change a value. Widgets that use it recalculate, and the parameter is marked temporary. The change stays on your screen. Refresh the dashboard, or reset that parameter, to return to the saved value. Other viewers keep the saved value. A parameter that is locked for viewers stays at the saved value in this panel. Shared links, the mobile app, and [PDF export](/products/building-bi/pdf-exports) use the saved dashboard values. ## Dashboard options Select the dashboard options icon in the edit mode sidebar to configure layout and display settings for the entire dashboard. ![Dashboard Options panel showing Canvas section with Size set to Auto and Background color toggle, Grid set to On drag and Resize with Background color toggle, Color Palette section with Restrict to Palette dropdown, Properties section with Swap charts and Push charts radio buttons, and Margins section with Top, Right, Bottom, Left all set to 0 px and Spacing set to 0 px](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-options.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=eb2f5de427812b89dab3f33cac59e495) Dashboard Options panel showing canvas size, grid, color palette, swap/push properties, and margins **Auto-Refresh** `Field` Set a refresh interval for the dashboard. Choose shorter intervals (such as every minute) for live operational data, or longer intervals (hourly or daily) for historical trends. **Grid Lines** `Toggle` Show or hide grid lines on the dashboard canvas to help align widgets. **Background Color** `Field` Set the background color for the dashboard canvas. **Push/Swap Charts** `Toggle` When enabled, dragging a widget pushes or swaps adjacent widgets instead of overlapping them. This keeps the layout organized as you rearrange widgets. **Canvas Size** `Field` Choose between `Auto Size`, `Fixed`, or `Max Width`. `Auto Size` adjusts the canvas to the viewer's screen. `Fixed` sets a specific pixel width and adds a horizontal scroll bar on smaller screens. `Max Width` limits the canvas to a maximum pixel width. **Page Margins** `Field` Controls the spacing around the edges of the dashboard canvas. **Mobile Layout** `Toggle` Toggle the mobile layout icon to reorganize and resize widgets for smaller screens. The mobile editor shows a phone-shaped canvas with a `Layout Setup` panel. Use `Place All` to auto-arrange widgets, or drag them manually. Remove individual widgets with the `X` button on each card. ![Dashboard mobile layout editor showing a phone-shaped canvas with a KODE logo widget, a building image widget, and a weather widget, and a Layout Setup panel on the right with Place All and Remove All buttons and a No charts available message indicating all charts have been placed](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-mobile-layout.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=152c0f90c502e201050da705bfcf4859) Mobile Layout editor showing a phone-shaped canvas with widget cards and the Layout Setup panel ## Default widget style The `Default Widget Style` panel sets baseline styling for all new widgets you add to the dashboard. Select the default widget style icon in the edit mode sidebar to configure paddings, background color, title font, and tooltip settings. Any widget you create after setting these defaults inherits these values automatically. ![Default Widget Style panel showing Paddings with Left, Top, Right, and Bottom all set to 0 px, Background with Fill Color toggle, Title section with Word wrap checkbox and Font set to Manrope 14 px with bold, italic, uppercase, underline, and color options, and Tooltip section with Icon Color setting](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-default-style.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=a33e32a9bc0947eb82205fcf3e01c6b3) Default Widget Style panel showing padding, background, title font, and tooltip settings ## Template Library The `Template Library` panel in the edit mode sidebar lets you browse and add chart and page templates directly to the dashboard you are editing. See [Templates](/products/building-bi/templates) for full documentation. ![Template Library panel with Charts filter selected showing Organization Templates tab with chart templates including Estimated Emissions by Service Type, Usage Breakdown by Service Type, Zone Temperature vs Effective Setpoints, Occupied AHUs, and Occupied FCUs](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-template-library.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=5bf3722ceeca54a4ad48d1ab90f3f34d) Template Library panel in the dashboard edit sidebar showing chart templates ## Manage dashboards The `My Dashboards` section lists all dashboards you have created or have access to. Click the star icon next to a dashboard name to mark it as a favorite. Favorited dashboards appear in the left navigation pane for quick access. Select the three-dot menu on any dashboard row for additional options. ![My Dashboards table showing a three-dot menu on the Operations Dashboard row with Edit, Duplicate, Permissions, Save as template, and Delete options](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=d7875607d8703455512ae27059c16702) Dashboard three-dot menu with Edit, Duplicate, Permissions, Save as template, and Delete options | Action | Description | | - | - | | `Edit` | Update the dashboard name, timezone, or description | | `Duplicate` | Create a copy of the dashboard with all its widgets | | `Permissions` | Add collaborators to the dashboard | | `Save as template` | Save the dashboard layout as a reusable template | | `Delete` | Permanently remove the dashboard | ### Dashboard permissions Select `Permissions` to manage who can edit the dashboard. Use the `Collaborators` tab to add individual users. Collaborators receive read and edit access, including the ability to manage other collaborators. The dashboard owner is displayed at the top and cannot be removed or reassigned. The `Roles` and `Users` tabs are legacy. Use [collections](/products/building-bi/collections) to grant view access by role. See [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ![Dashboard Permissions dialog for Operations Dashboard showing Owners as Diellza Gashi, Roles, Users, and Collaborators tabs with the Collaborators tab active displaying a table with Urtina Gashi as SuperAdmin and an Add Users button](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-permissions.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=9eaa59be3372c00b8e17b5583465666f) Dashboard Permissions dialog showing the Collaborators tab with users and roles ## Dashboard actions menu Select the three-dot menu in the top-right corner of a published dashboard to access sharing, export, and scheduling options. ![Operations Dashboard in Published state showing the three-dot menu with Share, Deploy, Export, Version History, and Schedule PDF Report options, with Overview, Device Details, and Floor Plans tabs and a weather widget visible](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-actions-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8609ea4442695f5e6e6b5c8dcaf50b6d) Dashboard actions menu with Share, Deploy, Export, Version History, and Schedule PDF Report options ## Share dashboards and widgets You can share entire dashboards or individual widgets through shareable links. ### Share a dashboard **1. Open the share dialog** Select the three-dot menu on the dashboard and choose `Share`. **2. Configure share settings** Set the pages to share, access expiration period, link title, refresh rate, and allowed IPs. The dialog also shows `Active` and `Expired` shared links. ![Sharing properties dialog showing an info banner about dashboard data reflecting current filters, Choose pages to share set to All selected, Access Expiration set to 1 hour, Link title field, Refresh rate set to None, Allowed IPs field set to wildcard, Active 0 and Expired 4 tabs, and Cancel and Generate Link buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-share.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=045755421c41ed2c3d851b0d29b63646) Sharing properties dialog with page selection, expiration, refresh rate, and IP restrictions **3. Generate and copy the link** Select `Generate Link`, then select the link icon to copy the URL to your clipboard. ### Share an individual widget Select the three-dot menu on any widget and choose `Share`. The widget share dialog provides the same options as the dashboard share dialog. ### Manage shared links The `Active` and `Expired` tabs at the bottom of the Sharing properties dialog list all generated links. To revoke access, delete the link from the Active list. For portfolio-wide link management, see [Building BI settings](/products/building-bi/settings#shared-links). ## Export and schedule PDF reports Use the dashboard three-dot menu to export a one-time PDF or create a recurring scheduled report. Full steps, fields, and schedule management are in [PDF exports and scheduled reports](/products/building-bi/pdf-exports). > [!NOTE] > > Create one-time exports and schedules in [PDF exports and scheduled reports](/products/building-bi/pdf-exports). Manage active links and schedules in [Building BI settings](/products/building-bi/settings). For who can share or schedule, see [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ## Publish a dashboard **1. Open the publish dialog** Select `Publish` in the top-right corner of the dashboard while in edit mode. **2. Confirm publishing** Review the confirmation window and confirm to publish the dashboard. The status changes from `Draft` to `Published`. > [!WARNING] > > Publishing makes the dashboard available to all users with access to Building BI. Verify your dashboard content before publishing. ## Version history Version history tracks every save, publish, and restore action on a dashboard. Every saved version is stored with its date, author, and an optional name. You can preview any past version, restore it as a draft, and maintain a complete audit trail of all published changes. ### Access version history You can open version history in two ways: * **From the three-dot menu** -- select the three-dot menu on the dashboard and choose `Version history`. History opens in a new tab. * **From the status chip** -- select the `Published` or `Draft` chip at the top of the dashboard, then choose `Version History`. The version timeline opens alongside the dashboard preview. ![Opening a draft dashboard, selecting Version history from the three-dot menu, and loading Version History in a new browser tab](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-history-open.gif?s=e9b39ebd97f678f30651db232fa8048e) Opening Version history from the dashboard three-dot menu ![Operation Dashboard version history with Cancel and Restore as Draft actions, dashboard preview on the left, and a Version history panel listing Published and Previously Published entries with pencil icons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-history.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=9b8ceaaad33e1b5174259e89d9b4cdcf) Version History panel showing a timeline of published, draft, and restored versions Each entry shows the timestamp, author initial, and status label: * **Published** -- the currently live version. * **Previously Published** -- a past version that was live at the time. * **Previous Version** -- a saved draft that was never published. * **Restored** -- a version that was restored from history. ![Version History panel showing entries for 11/12/2025 Published, 19/09/2025 Previously Published, 02/06/2025 Previous Version, 02/06/2025 Previously Published with an edit icon, and 02/06/2025 Previously Published](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=981f08655b5b2963115783ab09b55a7a) Version History timeline with entries showing status labels and an edit icon on the selected version > [!TIP] > > Select the pencil icon on any version entry to give it a descriptive name. Clearing the name reverts the label to the original timestamp. ### Work with drafts Draft mode lets you make changes to a dashboard without affecting what other users see in the published version. **1. Enter draft mode** Select `Edit Dashboard` to open the active draft. If no draft exists, one is created automatically. **2. Make and save changes** Edit the dashboard as needed. Select `Save Draft` to save your progress. Draft changes remain private and do not affect the live dashboard. **3. Publish the draft** When your changes are ready, select `Publish` to make the draft the new live version. Use the `Published`/`Draft` chip dropdown to switch between the read-only published version and your active draft at any time. ### Restore an older version **1. Open version history** Access `Version History` using either method described above. **2. Preview a version** Select any version in the list to preview its contents on the dashboard canvas. Select the pencil icon on an entry to rename it. **3. Restore or publish** Choose one of the available actions: * **Restore as Draft** -- available for all versions. Creates a new draft with the selected version's contents without affecting the currently published dashboard. * **Publish** -- available when a previous version is selected. Makes the selected version the live dashboard immediately. ![Version history header showing Cancel, Restore as Draft, and Publish buttons next to the Version history panel](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-version-restore.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=58eaf875379243fc4799a7ee4836e54c) Restore as Draft and Publish actions for a selected previous version > [!NOTE] > > Restoring a version as a draft does not overwrite the current published dashboard. A new version history entry is added automatically when you publish the restored draft. ## Templates Templates let you save and reuse dashboard layouts, individual tabs, or chart configurations across dashboards and sites. See [Templates](/products/building-bi/templates) for full documentation on saving, importing, exporting, and applying templates. ## Role access Access to Building BI is controlled through roles in Launchpad. **1. Navigate to role settings** Go to `Launchpad` > `Apps` > `KODE OS` > `Roles`. **2. Enable Building BI permissions** Locate the BBI module and enable `Read` or `Read/Write` permissions for the appropriate role. > [!NOTE] > > You need admin access to modify role permissions. Contact KODE Support if you do not have the required access level. ## Sensor health and data quality dashboards Platform **point bounds** flag readings outside expected ranges with an **Out of Range** state. Building BI does not surface a default sensor health view automatically. Data analysts should build dashboards that make out-of-range points visible to operators. ### Recommended dashboard views | View | Purpose | | - | - | | **Out-of-range point list** | Table of points currently outside configured bounds, with device, area, and last value | | **Counts by area or device** | Bar or KPI widgets that prioritize calibration work by floor, system, or equipment | | **Trend with bounds context** | Time-series charts filtered to out-of-range events for investigation | ### Build a sensor health dashboard **1. Use point time series data** Build from a Point Time Series data source. Run **Sync Datasource** after bounds are enabled so the latest status fields are available. See [Point bounds and unit conversion](/products/building-bi/data-sources#point-bounds-and-unit-conversion). **2. Filter out-of-range readings** Add filters or calculated columns that exclude or highlight readings where `cur_state` includes **Out of Range**. Use platform bounds logic instead of static ontology thresholds where possible. **3. Exclude bad data from KPIs** In metrics that power portfolio rollups, exclude out-of-range values so failing sensors do not skew averages or totals. **4. Deploy across sites** Save the dashboard as a [template](/products/building-bi/templates) or deploy through [Deployment Manager](/products/building-bi/deployment-manager). Use unit conversion in metrics when the same ontology field reports in different units across buildings. > [!TIP] > > Start from the **Data Quality** global template in [Templates](/products/building-bi/templates#global-templates), then extend it with bounds-aware filters and prioritization views. ## Related reading > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Match chart types to the question you need to answer. > [card] [How filtering works](/products/building-bi/concepts/how-filtering-works) > > Learn how filters interact across widgets and pages. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup requirements for every widget type. > [card] [Filter options](/products/building-bi/reference/filter-options) > > Review operators, scopes, and filter configuration fields. ## Next steps > [card] [Widget customization](/products/building-bi/widget-customization) > > Customize chart styles, colors, and layouts for your dashboard widgets. > [card] [Collections](/products/building-bi/collections) > > Organize dashboards into collections for easier navigation. > [card] [Data sources](/products/building-bi/data-sources) > > Connect and manage the data sources that power your dashboards. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboards across multiple sites from a single template. # Data sources Source: https://docs.kodelabs.com/products/building-bi/data-sources Add, configure, optimize, and preview data sources that power Building BI dashboards and calculations. Data sources supply the underlying data for Building BI dashboards. Each data source defines the columns, metrics, and calculations available to your charts and widgets. > [!NOTE] > > For data model context, see [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources), [Point time series hierarchy](/products/building-bi/data-sources#polling-and-data-structure), [Data source types](/products/building-bi/reference/data-source-types), [calculated fields](/products/building-bi/reference/calculated-fields), and [table structures](/products/building-bi/reference/table-structures). ## In this guide > [card] [Choose a source](#data-source-types) > > Compare physical, virtual, and key time-series sources. > [card] [Inspect schema](#data-source-schema) > > Preview columns, samples, and toolbar actions. > [card] [Add calculations](#calculated-columns-metrics-and-urls) > > Create columns, metrics, and URL fields. > [card] [Parameters](#parameters) > > Declare a value once and reuse it in SQL and dashboards. > [card] [Optimize and validate](#optimize-virtual-data-sources) > > Optimize sources, check column usage, and apply point bounds. > [card] [Replace a data source](#replace-or-delete-a-data-source) > > Check dashboard usage, then replace or delete a source. > [!NOTE] > > Navigate to `Building BI` and select `Data Sources` in the left navigation panel. ![Data Sources page showing a table of data sources with columns for Name, Type (Physical or Virtual), Database Type (CLICKHOUSE, POSTGRES, or BIG\_QUERY), Description, and Date Added, with a Search bar and Add Data Sources button](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=801948d90bae5f886cde8e17d0161ba5) Data Sources page showing all available data sources with their type, database type, and description > [!WARNING] > > Changes to data sources, calculated columns, and metrics are portfolio-wide. Any modification affects all dashboards across the entire portfolio, not just a single building. ## Data source types Building BI supports two data source types: * **Physical** -- Maps directly to a database table managed by the backend or a [Building Data Hub](/products/bdh/quickstart/introduction) (BDH) pipeline. Physical data sources reflect the raw data stored in your connected database. * **Virtual** -- Built from SQL queries (views) on top of physical tables. Virtual data sources give you flexibility to create custom datasets without modifying the underlying database. You can edit a virtual table's SQL by clicking the three-dot menu on its row. Both types expose columns and metrics that you can use when building dashboard charts. When you select a chart in edit mode, the `Chart Configuration` panel lets you pick a data source and drag its metrics into the X-Axis, Y-Axis, and Legend fields. ![Dashboard in edit mode showing the Chart Configuration panel with Setup and Style tabs, a Charts section with chart type icons and search, a Data Source dropdown set to Timeseries Last Va, a Metrics list including Total Count, One Metric, Cooling Request Pe, Heating Request P, Percent Running St, Device ID, Zone Temp Inside, and more with fx buttons, X-Axis set to Area Name, and Legend and Y-Axis drop zones](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-chart-config.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=58d36dfb7dd5bbe1bf0b93ef5e7d4676) Chart Configuration panel showing a selected data source and its available metrics The Data Sources page provides two tabs: `All Datasources` lists every data source in your portfolio, and `Favorites` shows only data sources you have starred. Select the star icon on any row to add it to your favorites. ![Data Sources page showing the Favorites tab with a single starred data source RTU Details of type Virtual and CLICKHOUSE database type added 3 minutes ago](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-favorites.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=317b6ba053d2e65956a4a4d314a9a87b) Favorites tab showing starred data sources for quick access Select the three-dot menu on any row in the data sources list to access `Edit Details`, `Check Usage`, `Replace Usage`, or `Delete`. ![Data Sources list three-dot menu open on a row showing Edit Details, Check Usage, Replace Usage, and Delete](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/kode-os/building-bi/bbi-datasources-row-menu-replace.png?fit=max\&auto=format\&n=Hw1Nqnl-vSrg3D4i\&q=85\&s=f2f140fa1a9ab6507310ab18c44f331c) Data source row menu with Check Usage and Replace Usage > [!NOTE] > > Before you delete a source, use [Check Usage and Replace Usage](#replace-or-delete-a-data-source) to move dashboard references. Widgets that still point at a deleted source show a defined error instead of failing silently. > [!NOTE] > > BDH pipelines automatically appear as physical data sources after you create them in the Building Data Hub module. ### Virtual table considerations Virtual tables are being phased out for historical trending in favor of BDH pipelines. The long-term direction is to use virtual tables only for real-time data, since they are less efficient for high-dimension calculations. * You can create virtual tables on ClickHouse and PostgreSQL data sources. * You cannot create virtual tables on BigQuery. Use BDH pipelines instead. ## Database types Building BI connects to three database engines. Each stores a specific category of data, and each requires its own SQL dialect for calculated columns and metrics. | Database | Purpose | Virtual table support | | - | - | - | | **ClickHouse** | Real-time sensor data (Point Time Series tables) | Yes | | **PostgreSQL** | Non-sensor multidimensional data with many columns | Yes | | **BigQuery** | Module data and BDH pipeline outputs (FTT, FDD, OSS) | No -- use BDH instead | > [!WARNING] > > Tables do not join across database types. You cannot combine a ClickHouse table with a BigQuery table in a single query. When writing calculated columns or metrics, use the SQL syntax that matches the database type of the data source. ClickHouse, PostgreSQL, and BigQuery each follow different SQL dialects. ## Key data sources While many tables exist, two primary sources cover the majority of sensor-related use cases: | Choose Real-Time when… | Choose Last Value when… | | - | - | | You plot trends or history | You show current status or "now" tiles | | Time alignment across readings matters | You compare sensors with different poll rates | | You need every reading in a range | You only need the latest value per point | ### Point Time Series Real-Time The core sensor table where every reading creates a new row. This is the source of truth for building sensor data. Slight variants exist that poll less frequently — use those only when loading time is a concern. Point Time Series Real-Time runs on ClickHouse, so all calculated columns and metrics on this table must use ClickHouse SQL syntax. ### Point Time Series Last Value Returns only the most recent recorded value per sensor. Search `Last Value` in the data sources list to find this table. > [!NOTE] > > Last Value rows are not a synchronized snapshot. Each row is the most recent reading for that sensor, regardless of timestamp. Do not use them for time-sensitive math that assumes every sensor sampled at once. ### Aggregated tables Some data sources aggregate readings at fixed intervals (15-minute, hourly, daily, or monthly). Aggregated tables return summary values (average, sum, maximum, minimum, count, or delta) for each point during the polling period. Aggregation is valuable for some sensor types. Hourly average air temperature shows how a space generally felt, while an hourly average of elevator floor level is less meaningful. ### Polling and data structure Each point time series table contains one row per data point at a given time period, along with context columns identifying the device, area, and building. You may see multiple rows from the same device at the same timestamp if they come from different points. Prefer ID columns over name columns for filters and calculations. Names are editable and not guaranteed unique. Each row carries nested layers of context around the data point, from the building level down to the individual sensor value: ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart TB subgraph building["Building Level"] B1["building_id / building_name"] B2["building_region · building_type\nbuilding_sqft · building_timezone"] end subgraph area["Area (Floor) Level"] A1["area_id / area_name"] end subgraph device["Device (Equipment) Level"] D1["device_id / device_name"] D2["device_mechanical_type\ndevice_class · device_zone"] end subgraph point["Point (Sensor) Level"] P1["point_id / point_name"] P2["point_kind · point_unit · point_enum"] end subgraph data["Data"] V1["date_time · date_time_local"] V2["number_value · string_value\nboolean_value · enum_mapping"] V3["cur_status · cur_state · point_writable"] end B1 --> A1 --> D1 --> P1 --> V1 classDef Sky stroke-width:1px, stroke-dasharray:none, stroke:#374D7C, fill:#E2EBFF, color:#374D7C classDef Peach stroke-width:1px, stroke-dasharray:none, stroke:#FBB35A, fill:#FFEFDB, color:#8F632D classDef Rose stroke-width:1px, stroke-dasharray:none, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Green fill:#B0E4CC, color:#285A48, stroke:#285A48 class B1,B2 Sky class A1 Sky class D1,D2 Peach class P1,P2 Rose class V1,V2,V3 Green linkStyle 0,1,2,3 stroke:#00C853,fill:none ``` Two common polling patterns exist: * **Change of value (COV)** -- A new row is created only when the value changes beyond the COV threshold, with a maximum interval of one hour between rows. * **Structured polling** -- A new row is created at every polling interval (every 1, 2, 5, 10, or 15 minutes) regardless of whether the value changed. > [!TIP] > > Check the `Point` page and `Device` page in the left navigation bar to understand which points and devices exist in the building before building queries against point time series tables. ## Data source schema Selecting any data source name opens its schema view. The schema reveals the building blocks available for your dashboards across five tabs: `Columns`, `Calculated`, `Metrics`, `URLs`, and `Actions`. ![Edit RTU Details schema view showing Virtual and Not Optimized badges, Schema and Samples tabs, a warning about changes affecting all charts, and columns tab with a table of columns including building\_id, building\_name, building\_timezone, building\_region, building\_type, building\_sqft, building\_brand, building\_phone\_number, area\_id, area\_name, datasource\_id, and datasource\_name with their display names, descriptions, data types, hidden status, and sensitive value flags](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-schema.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=9a0dd8aeb716681835daf1051ec2bb89) Data source schema view showing columns with their display names, data types, and visibility settings | Tab | Description | | - | - | | `Columns` | Native database columns that exist in the underlying table | | `Calculated` | Custom single-row logic columns you create with SQL expressions | | `Metrics` | Aggregate-level calculations that recalculate based on chart grouping | | `URLs` | Internal or external links generated from row data | | `Actions` | Actionable operations available on the data source | ### Schema toolbar actions From the top of the schema view, you can: * **`Sync Datasource`** -- Pull in the latest columns if the underlying KODE table or BDH pipeline was updated. * **`+ Add Column`** -- Create a new calculated column, metric, or URL. * **Three-dot menu** -- Access `Check Column Usage` to see which dashboards reference specific columns, `Check Optimization` to review virtual table performance, or `Edit Details` to change basic parameters. ![Data source schema view three-dot menu showing Check Column Usage, Check Optimization, and Edit Details options](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=b1fc4d2726ef58dbddc7bc38bb54d83b) Three-dot menu showing Check Column Usage, Check Optimization, and Edit Details options ### Samples tab The `Samples` tab previews a subset of records from the data source before you build charts. Use it to validate fields, confirm virtual table SQL, and inspect example values without creating a report first. **1. Open a data source** Navigate to `Building BI` > `Data Sources` and select a data source name. **2. Open Samples** Next to the `Schema` tab, select `Samples`. **3. Review the preview** The table shows available columns and example values. The preview is read-only and limited to approximately 20 rows for performance. Changes you make to the data source are reflected automatically when you return to **Samples**. Native columns and calculated columns appear together in the preview. Calculated columns show an `i` icon in the column header. Select the icon to open the column's query. Use that when you are writing other calculated columns or metrics from the same source. ![Edit Point Timeseries Samples tab showing a Physical data source with an info banner stating this is a preview with a maximum of 20 rows visible, and a table with columns for Connector ID, Building ID, Building TZ, Device ID, Field, Kind, Measurement, and Unit](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-samples.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=292eb4780eb0b35b522bc27b46a2dd93) Samples tab showing a preview of 20 rows from a physical data source Both **physical** and **virtual** data sources support sample preview across ClickHouse, PostgreSQL, and BigQuery dialects. > [!TIP] > > Calculated columns appear at the end of the sample table. Look for the `i` icon in the header to confirm a column is calculated, then select it to inspect the expression. | Scenario | What you see | | - | - | | **Structure with no rows** | Column headers display with a **No results** message | | **Calculated column errors** | Invalid calculated columns are omitted from the preview to avoid confusion | | **After schema changes** | Reopen **Samples** or sync the data source to refresh the preview | > [!NOTE] > > Sample preview is for validation, not full data exploration. Use dashboards and charts for analysis workflows. ## Calculated columns, metrics, and URLs Calculated columns, calculated metrics, and URLs extend your data sources beyond raw columns. Use this section for SQL patterns and examples. For create steps, field options, data-type limits, and columns-versus-metrics graphics, see [Calculated fields](/products/building-bi/reference/calculated-fields). | Feature | Calculated columns | Calculated metrics | | - | - | - | | **Scope** | Single row | Multiple rows | | **Function** | Applies logic to create a new virtual data field | Aggregates data (for example, SUM, AVG, COUNT) | | **Behavior** | Independent; does not aggregate | Dynamically recalculates based on chart grouping | > [!WARNING] > > Editing a calculated column, metric, or URL affects all dashboards portfolio-wide. Always validate your logic before saving. Changing a calculation can break multiple live dashboards. ### Calculated columns Calculated columns apply row-level logic to produce a new value for each row independently, similar to a spreadsheet formula. Each calculated column contains a single SQL expression. Use calculated columns to: * Extract time components for filtering (for example, `toHour(date_time_local)` returns the hour as an integer). * Isolate a specific sensor's values using conditional logic (for example, return `number_value` only when `ontology_point_field` matches a target, otherwise return null). * Plot multiple sensor readings side-by-side in a single chart. The examples below use the Point Time Series Real-Time table, which runs on ClickHouse. All calculated columns and metrics on this table must follow ClickHouse SQL syntax. Match the dialect of your source: [PostgreSQL](https://www.postgresql.org/docs/current/), [ClickHouse](https://clickhouse.com/docs/sql-reference), or [BigQuery](https://cloud.google.com/bigquery/docs/reference/standard-sql/query-syntax). #### Column rules * Each calculated column must have a unique name within the data source. * Column names must use the exact database field names (for example, `building_name`, not "Building Name"). * You cannot edit a calculated column's SQL expression from the chart `fx` editor. Edit it in `Data Sources` directly. #### Metadata syntax on Real-Time tables When referencing metadata fields (such as `building_name`, `device_name`, or `ontology_point_field`) on the Point Time Series Real-Time table, you must wrap them in the `dictGetString` pattern: ```sql Real-Time metadata example theme={"theme":{"light":"github-light","dark":"github-dark"}} if ( dictGetString( 'point_time_series.metadata_dictionary', 'ontology_point_field', tuple(point_id) ) = 'discharge_air_pressure_setpoint', number_value, null ) ``` Replace `discharge_air_pressure_setpoint` with any `ontology_point_field` value. Use the appropriate payload column (`number_value`, `string_value`, or `boolean_value`) depending on the point's data type. #### Simplified syntax on Last Value tables The Last Value table is pre-processed, so you can reference metadata columns directly without `dictGetString`: ```sql Last Value metadata example theme={"theme":{"light":"github-light","dark":"github-dark"}} if ( ontology_point_field = 'discharge_air_pressure_setpoint', number_value, null ) ``` ### Calculated metrics Calculated metrics perform aggregate calculations across multiple rows. Unlike columns, metrics dynamically recalculate based on your chart's grouping. If a chart is grouped by hour, the metric produces one value per hour. If grouped by device, it produces one value per device. Use aggregate functions like `sumIf`, `countIf`, or `avgIf` to filter rows before aggregating. You can combine multiple functions to build complex logic. **Example: net occupancy metric** This metric calculates occupancy by subtracting people leaving from people entering: ```sql Net occupancy (Real-Time table) theme={"theme":{"light":"github-light","dark":"github-dark"}} sumIf( number_value, dictGetString( 'point_time_series.metadata_dictionary', 'ontology_point_field', tuple(point_id) ) = 'people_entering_counter' ) - sumIf( number_value, dictGetString( 'point_time_series.metadata_dictionary', 'ontology_point_field', tuple(point_id) ) = 'people_leaving_counter' ) ``` > [!NOTE] > > Columns operate on a single row. Metrics aggregate across multiple rows. Use a column when you need a per-row value (for dimensions or filters). Use a metric when you need an aggregated result (for chart values). ### URLs URL columns turn data into navigation actions in your dashboards. #### Internal URLs Internal URLs follow the pattern `/buildings/{building_id}` and navigate within KODE OS on both desktop and mobile. Building BI validates the IDs automatically. > [!TIP] > > Add a `Device URL` to table widgets for a quality-of-life improvement. In the widget style settings, set the URL option on the device name column to `Device URL`. Each device name cell becomes a hyperlink to that device's page, letting users jump directly from a dashboard finding to the relevant device. #### External URLs External URLs open in a new browser tab, allowing users to navigate to resources outside KODE OS such as a CMMS system or a specific work order. For URL behavior on chart widgets, data-type limits on metrics, and `Hidden` or `Sensitive Values` options, see [Calculated fields](/products/building-bi/reference/calculated-fields). ## Parameters A parameter is a named value on a data source. Reference it as `@name` in calculated column SQL, calculated metric SQL, and virtual data source SQL. Each dashboard can store its own value. A viewer can change a value for a private what-if. See [Dashboard parameters](/products/building-bi/dashboards#dashboard-parameters). A parameter is separate from a [filter](/products/building-bi/dashboards#dashboard-filters). A filter chooses which rows a widget reads. A parameter changes what a calculation computes. ### Declare a parameter **1. Open Parameters** Open `Building BI` > `Data Sources`, open a data source, and select `Parameters`. **2. Add a parameter** Set the name, display name, description, data type, and default value. Add allowed values when the choices are known. | Field | Description | | - | - | | **Name** | Technical name used in SQL as `@name`. It must be unique among parameters, columns, metrics, URL columns, and actions. | | **Display name** | Label shown in the dashboard panels. | | **Description** | Optional explanation of the value. | | **Data type** | `String`, `Integer`, `Double`, `Boolean`, `Date`, `Date & Time`, or `Array`. | | **Default value** | Value every dashboard starts from. Reset returns to this value. | | **Allowed values** | Optional list. The control becomes a dropdown. | | **Value is required** | Widgets on this data source need a value before they can run. | | **Overridable at dashboard level** | Dashboards can store their own value. Leave this off to keep the data source default on every dashboard. | | **Locked for viewers** | Dashboard editors can set the value. Viewers keep the saved value. | **3. Save the data source** Save the data source. Dashboards that already use the source keep working. A source with no parameters is unchanged. Editing a parameter requires permission to edit the data source. Saving a dashboard value requires permission to edit the dashboard. A what-if requires permission to view the dashboard. ### Reference a parameter in SQL In a calculated column, calculated metric, or virtual data source query, type `@` and select the parameter. You can also select it from the parameter palette beside the editor. A reference inside a quoted string or a SQL comment stays as text. Save rejects a reference to a parameter that is not declared. Before you rename or delete a parameter, Building BI lists every calculated column, metric, and virtual query that uses it. Delete stays unavailable while the parameter is in use. Parameters are available in calculated columns, calculated metrics, and virtual data source SQL. A dashboard or page filter on a calculated column that references a parameter also uses the current value, including that filter's value list. An `Array` parameter is written as a parenthesized list, so you can use it with `IN`. Building BI checks each value against the declared type before the query runs. ClickHouse, PostgreSQL, and BigQuery each receive a typed literal. URL columns, actions, widget titles, sorts, and conditional formatting do not accept parameters. ## Add a data source **1. Open the data sources page** Navigate to `Building BI` > `Data Sources`. **2. Start a new data source** Select `+ Add Data Sources` and choose `Physical` or `Virtual`. **3. Configure the data source** On the `Details` tab, complete the required fields: | Field | Description | | - | - | | **Database Type** | The database engine for the source connection (ClickHouse, PostgreSQL, or BigQuery) | | **Database** | The target database name (consult support, a data analyst, or copy from an existing client) | | **Schema** | The database schema for the source table (consult support, a data analyst, or copy from an existing client) | | **Name** | The internal identifier for the data source | | **Display Name** | A human-readable name shown in dashboard configuration panels | | **Description** | Optional summary of the data source's purpose | ![Add Data Source dialog with Virtual selected, Details tab active, showing Database Type set to CLICKHOUSE, Database set to point\_time\_series, Name set to rtu\_details, Display Name set to RTU Details, a Description field, and Cancel and Save buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-add-details.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=444effa6c9dd9d45f052d3bdff194201) Add Data Source dialog showing the Details tab for a virtual data source For virtual tables, switch to the `SQL Expression` tab to define the query. The `Source Tables` field lists the tables referenced in your SQL. Write the SQL expression using the syntax that matches the selected database type (PostgreSQL or ClickHouse). > [!TIP] > > Review existing virtual tables for SQL syntax examples. You can also consult the database engine documentation or use an LLM for query construction. LLMs handle standard ClickHouse and PostgreSQL syntax well, though they may not know KODE OS-specific table structures. ![Add Data Source dialog with Virtual selected, SQL Expression tab active, showing Source Tables listing connector\_time\_series, device\_time\_series, and point\_time\_series aggregated\_last\_values, and a SQL Expression editor with a query using dictGetString on point\_time\_series metadata\_dictionary](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-add-sql.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=d6abbcaad3735183b486ab2cbf6a96eb) Add Data Source dialog showing the SQL Expression tab with source tables and query editor **4. Save the data source** Select `Save` to add the data source to your list. A confirmation toast appears. ![Datasource created successfully confirmation toast](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-created-toast.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8fdb62a7590002fc7eeb99041e53ad02) Confirmation toast after creating a data source > [!NOTE] > > Creating new data sources is uncommon. Try to solve problems with existing data sources first. If a table exists at another client but is missing from yours, add it using the same connection details. ## Optimize virtual data sources Unoptimized virtual data sources load slower and can produce errors with large datasets. A warning banner reading "Not Optimized" appears at the top of any unoptimized data source. See [dashboard performance](/products/building-bi/concepts/dashboard-performance) for broader optimization guidance. ### Optimize from the data source page **1. Open the data source** Navigate to `Data Sources` and select the virtual data source you want to optimize. **2. Edit the SQL expression** Select the three-dot menu and choose `Edit Details`. Switch to the `SQL Expression` tab to review and modify the query. An `Optimize your Virtual Datasource` section appears at the bottom with suggestions. ![Edit RTU Details dialog with Virtual selected, SQL Expression tab showing Source Tables and SQL code editor with ClickHouse query, and an Optimize your Virtual Datasource expandable section at the bottom](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-edit-sql.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=f5a9e433284bbda9373cd7f21f98cd1b) Edit Details dialog showing the SQL Expression tab with optimization suggestions **3. Apply optimization suggestions** Expand the `Optimize your Virtual Datasource` section. The system generates AI-powered filter suggestions to limit the data retrieved from the source. Review the suggestion and apply it to improve query performance. ![Optimize your Virtual Datasource section showing an AI-generated note about applying filters, a suggested filter template with column\_name\_filter placeholder, and expandable sections for point\_time\_series.aggregated\_last\_values and point\_time\_series.metadata source tables](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-optimize.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2154609381db4a7d3cbd2e1ac108cf4a) Optimization suggestions with AI-generated filters for source tables **4. Save your changes** Select `Save` to apply the optimization. ### Identify unoptimized sources from a dashboard You can also check optimization status while editing a dashboard. Click `Edit Dashboard`, select a chart, and open the `Setup` panel. The `Data Source` dropdown flags any unoptimized sources so you can address them directly. ## Check column usage Unused columns add overhead to your data sources. Use the column usage check to identify and remove them. **1. Open column usage** From the data source schema view, select the three-dot menu and choose `Check Column Usage`. **2. Select what to check** Choose which categories to scan: `Check Columns`, `Check Calculated`, and `Check Metrics`. Each category shows the total number of items. Select `Check` to run the scan. ![Check Usage dialog stating You are about to check usage of columns in this Data Source, with checkboxes for Check Columns with 51 Total Columns, Check Calculated with 0 Total Columns, and Check Metrics with 1 Total Columns, and Cancel and Check buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-datasources-check-usage.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=cbff4b9ef9b343ed03fbece7a095e33d) Check Usage dialog showing column, calculated, and metrics categories to scan **3. Remove unused columns** Review the results. Columns marked "Unused" can be safely deleted to reduce source overhead. ## Replace or delete a data source Use the data source row menu to see which dashboards use a source, move those references to another source, or delete the source. This check is separate from [Check column usage](#check-column-usage), which scans unused columns inside one source. **1. Check usage** On `Building BI` > `Data Sources`, open the row menu and select `Check Usage`. The usage dialog shows how many dashboards read from the source, with **Published**, **Unpublished**, and **Total** counts. ![Data Quality All usage dialog stating 1 dashboard reads from this data source, with Published 1, Unpublished 0, and Total 1](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/kode-os/building-bi/bbi-datasources-check-usage-summary.png?fit=max\&auto=format\&n=Hw1Nqnl-vSrg3D4i\&q=85\&s=5cf3abd950b65902ed4f09c0125459a1) Check Usage summary for a data source **2. Choose a replacement** Select `Replace Usage`. Choose a replacement data source in the same organization. **3. Map fields** Select `Auto Resolve` to match items that share an internal name and a data type. Then map any remaining items by hand, and only to an item of the same data type. Use `All`, `Mapped`, and `Unmapped` to review the list. Search inside each section. Sections cover columns, metrics, calculated columns, URLs, actions, and parameters. ![Animated walkthrough of Replace Usage mapping columns from one data source to another in Building BI](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/kode-os/building-bi/bbi-datasources-replace-usage.gif?s=ad7973487b018e257309b58e08246685) Replace Usage workflow mapping fields between data sources **4. Confirm** Review how many items are still unmapped, then confirm. Keep the original data source, or replace usage and delete it after the move succeeds. While the job runs, both data sources show an info icon and stay locked. Editing, deletion, and another replacement wait until the job finishes. An unmapped item stays in the widget. After the move, that widget reports that the column is missing on the replacement data source until you edit the widget and pick a field. The move updates widgets on dashboards and dashboard versions, plus dashboard filters and page filters. > [!NOTE] > > `Replace Usage` does not migrate dashboard templates or Building Data Hub pipelines. Those references stay on the original source. ### Delete a data source Select `Delete` from the row menu. Review the dashboards that still use the source. Replace usage and then delete, or delete with no replacement. Replacement uses the `Replace datasources` permission. Deletion uses the `Delete datasources` permission. See the [permissions reference](/products/launchpad/client-organizations/apps/permissions-reference). Widgets and filters that still point at a deleted source keep their configuration and show that the data source no longer exists. The deleted source is absent from data source selectors. Open the widget, select another data source, and rebuild the configuration. A failed replacement returns both sources to their prior state. A completed replacement stays in place. ## Point bounds and unit conversion KODE OS stores **point high/low bounds** and a **unit conversion foundation** in the platform data model. These capabilities support analytics and diagnostics workflows in Building BI. They do not change displayed point values or trend charts by default. > [!NOTE] > > Bounds and unit conversion are foundation capabilities. End-user value comes from dashboards, metrics, and filters your team builds on top of the platform data. ### Point high/low bounds The platform applies default minimum and maximum bounds per **ontology field** based on sensor or measurement type. Admins can review and adjust bounds per point in [Point modeling](/products/kode-os/devices/device-templates#point-modeling). When an incoming value exceeds configured bounds, the platform flags the reading with an **Out of Range** state. Use this in Building BI to: * Filter point time series data to exclude bad readings from KPIs and rollups * Build sensor health dashboards that list points currently out of range * Group counts by device, system, floor, or area for calibration prioritization * Replace dashboards that rely on static ontology bounds with platform bounds logic After bounds are enabled for your portfolio, run **Sync Datasource** on affected tables to pull the latest columns into Building BI. ### Unit conversion foundation The unit conversion layer normalizes compatible units within the same measurement type in the background. Use it in calculated columns and metrics when you aggregate data across buildings where the same point field may report in different units (for example, `°C` vs `°F`). | Applies to | Does not apply yet | | - | - | | Bounds evaluation across mixed units | Raw stored values in the database | | Metric calculations and normalization in BI | End-user displayed values in KODE OS UI | | Portfolio comparisons in dashboards | Trend chart display units | > [!NOTE] > > [Dynamic units](/products/building-bi/widget-customization#style-tab-reference) in widget **Style** settings control chart label formatting. They are separate from the platform unit conversion foundation used in data and metrics logic. ### Build cleaner metrics Use bounds and unit conversion together for more reliable KPIs: 1. **Normalize units** in calculated metrics when rolling up the same ontology field across sites with different `point_unit` values. 2. **Exclude out-of-range readings** so a small set of failing sensors does not skew portfolio averages or space-level rollups. 3. **Filter dashboards** on **Out of Range** in `cur_state` or related status fields to surface sensors that need calibration or replacement. > [!TIP] > > Check the **Data Quality** global template in [Templates](/products/building-bi/templates#global-templates) as a starting point for sensor health dashboards, then extend it with bounds-aware filters and metrics. ## Limitations Calculated columns and metrics do not support window functions or aggregations of aggregations (nesting aggregate functions). This is a calculated field limit, not a ClickHouse limit. Two workarounds exist: * **Virtual tables** -- Perform a window function or one level of aggregation in the virtual table SQL, then use the result as a regular column in your charts. * **[Building Data Hub](/products/bdh/quickstart/introduction)** -- Create a BDH pipeline to handle complex transformations outside of Building BI. > [!NOTE] > > SQL dialect differs per database type. A ClickHouse expression does not work on a PostgreSQL or BigQuery data source without modification. Always verify the database type before writing or copying SQL expressions. > [!TIP] > > Thousands of calculations have been written across KODE deployments. If you are stuck, review existing calculated columns and metrics in other data sources for working examples, or ask your team for help. ## Column reference The Point Time Series tables (Real-Time and Last Value) share a common column structure. Use this reference when building calculated columns, metrics, or filters. > [accordion] Timestamp columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `date_time_local` | Date Time Local | Date and Time | Localized timestamp adjusted to the building's timezone. Use for dashboards and user-facing visuals. | > | `date_time` | Date Time | Date and Time | UTC timestamp from the backend. This is the source-of-truth timestamp. | > [accordion] Entity identifier columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `building_id` | Building Id | String | Unique building identifier. Prefer this over `building_name` to avoid duplication issues. | > | `building_name` | Building Name | String | Building name. Can be duplicated across clients. | > | `datasource_id` | Datasource Id | String | Unique identifier for the data source providing this data. | > | `datasource_name` | Datasource Name | String | Name of the data source connection (for example, BMS or API integration). | > | `device_id` | Device Id | String | Unique identifier for the device (equipment) associated with the point. | > | `device_name` | Device Name | String | Device name (for example, AHU-1 or Pump-3). Editable and may not be unique. | > | `area_id` | Area Id | String | Unique identifier for the area (typically a floor level). | > | `area_name` | Area Name | String | Area name (usually a floor name). Aligns with floor plans if configured. | > | `point_id` | Point Id | String | Unique sensor or point identifier. Always prefer this over `point_name` for accuracy. | > | `point_name` | Point Name | String | Sensor or reading name. Can vary by naming convention. | > [accordion] Point classification columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `point_kind` | Point Kind | String | Data type of the point: Number, Boolean, or String. Determines which value column to use. | > | `point_unit` | Point Unit | String | Unit of measurement (for example, degrees F, %, or kW). | > | `point_enum` | Point Enum | String | Mapping for categorical values (for example, 1 = ON, 0 = OFF). | > | `point_writable` | Point Writable | Boolean | Indicates if the point can be overridden (true = writable from BI). | > [accordion] Value columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `number_value` | Number Value | Double | Numeric sensor reading. The most commonly used value field. | > | `string_value` | String Value | String | String-based value for points with multiple states (for example, modes or alarms). | > | `boolean_value` | Boolean Value | Boolean | Boolean value (true/false or 1/0). Often paired with enum mapping. | > | `enum_mapping` | Enum Mapping | String | Human-readable mapping of boolean or coded values. Prefer this over raw boolean. | > [accordion] Ontology columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `ontology_canonical_type` | Ontology Canonical Type | String | Standardized device type across all buildings (for example, AHU or Pump). | > | `ontology_canonical_type_name` | Ontology Canonical Type Name | String | Human-readable version of the canonical device type. | > | `device_mechanical_type` | Device Mechanical Type | String | Raw mechanical type assigned to the device (can vary by building or client). | > | `device_mechanical_type_name` | Device Mechanical Type Name | String | Display-friendly version of the mechanical type. | > | `ontology_entities` | Ontology Entities | String | Grouping field for organizing related components (less commonly used in BI). | > | `ontology_point_field` | Ontology Point Field | String | Standardized field name for the point. Normalizes inconsistent naming across sites. | > | `ontology_point_field_name` | Ontology Point Field Name | String | Human-readable version of the ontology point field. | > | `ontology_prefix` | Ontology Prefix | String | Prefix component of the ontology naming convention. | > | `ontology_suffix` | Ontology Suffix | String | Suffix component of the ontology naming convention. | > | `ontology_measurement` | Ontology Measurement | String | Measurement type (for example, Temperature or Pressure). | > | `ontology_aggregation` | Ontology Aggregation | String | Suggested aggregation type for the point (for example, avg or sum). | > | `ontology_descriptor` | Ontology Descriptor | String | Additional descriptive tag for the point within ontology. | > [accordion] Building metadata columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `building_region` | Building Region | String | Region metadata assigned at the building level (configured in Launchpad). | > | `building_type` | Building Type | String | Type of building (for example, Office or Retail). Configured in Launchpad. | > | `building_sqft` | Building Square Feet | Double | Total square footage of the building (Launchpad metadata). | > | `building_timezone` | Building Timezone | String | Timezone of the building. Used for localization of timestamps. | > | `building_brand` | Building Brand | String | Brand or ownership grouping of the building (Launchpad metadata). | > | `building_identifier` | Building Identifier | String | Additional identifier for grouping or referencing buildings. | > | `building_district` | Building District | String | District grouping for the building (Launchpad metadata). | > | `building_zone` | Building Zone | String | Zone grouping at the building level (Launchpad metadata). | > [accordion] Device metadata columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `device_tenant` | Device Tenant | String | Tenant grouping of the device (client-specific usage). | > | `device_class` | Device Class | String | Device classification (custom metadata set in the device module). | > | `device_zone` | Device Zone | String | Zone grouping of the device within the building. | > | `device_site_level` | Device Site Level | Boolean | Indicates if the device is site-level equipment. | > | `device_location` | Device Location | String | Physical or logical location of the device within the building. | > [accordion] Connectivity and status columns > > | Column | Display name | Type | Description | > | - | - | - | - | > | `cur_status` | Cur Status | String | Connectivity status of the point (OK, Fault, Disabled, or No Value). | > | `cur_state` | Cur State | String | Array of active states such as **Override**, **FDD**, **Stale**, and **Out of Range**. Requires parsing in BI. Use **Out of Range** to identify readings outside configured point bounds. | > | `datasource_type` | Datasource Type | String | Type of data source (API, BMS, AI). | > | `api_axslot_path` | Api Ax Slot Path | String | Backend reference path for API/BMS integration (primarily for engineering use). | > | `api_point_name` | Api Point Name | String | Original point name from the source system before normalization. | ## Related reading > [card] [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources) > > Compare direct tables with derived virtual sources. > [card] [Key data sources](/products/building-bi/data-sources#key-data-sources) > > Choose Real-Time or Last Value Point Time Series sources. > [card] [Database types](/products/building-bi/data-sources#database-types) > > Understand ClickHouse, PostgreSQL, and BigQuery trade-offs. > [card] [Column reference](/products/building-bi/data-sources#column-reference) > > Look up column names for calculations and filters. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts, tables, and widgets. > [card] [Widget customization](/products/building-bi/widget-customization) > > Customize chart styles, colors, and layouts for your dashboard widgets. # Deployment manager Source: https://docs.kodelabs.com/products/building-bi/deployment-manager Deploy Building BI dashboards across multiple buildings, manage predefined and custom views, and maintain portfolio-wide consistency. The Deployment Manager enables you to deploy dashboards across multiple buildings from the [portfolio view](/products/building-bi/overview#portfolio-and-building-scope). See [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work) and [templating versus deployment](/products/building-bi/concepts/templating-vs-deployment) to choose the right distribution approach. Only users with the `Sync/Bulk Deploy` permission can access it. ## Access the Deployment Manager Navigate to the portfolio view of Building BI and select `Deployment Manager` from the left navigation bar. You can also access deployment options directly from a dashboard by opening the three-dot menu on the dashboard and selecting `Deploy`. ![Building BI interface showing a published FDD events dashboard with the left navigation bar displaying Dashboard Collection with FDD events and Air Quality, Energy Usage with Energy Report and Spaces, My Dashboards with multiple dashboards, and Deployment Manager, Settings, Data Sources, and Templates at the bottom](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-dashboard-access.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=485721f72b580ee621e4ffb36c62c1c9) Building BI left navigation showing Deployment Manager at the bottom, with collections and dashboards listed above ## Deployment list The deployment list displays all current and past deployments with the following columns: | Column | Description | | - | - | | Deployment Name | Name assigned to the deployment | | Dashboard | Dashboard being deployed | | Deployment Description | Purpose or context for the deployment | | Status | Current state: Completed, Failed, or In progress | | Building | Source building for the deployment | | Deployed to | Number of target buildings | ![Deployment Manager page showing a search bar, Building dropdown filter, New Deployment button, and an empty deployment table with Deployment Name, Dashboard, Deployment Description, Status, Building, and Deployed To columns displaying No deployments yet](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=d5b4c96871dbe14ed4879a9d9edbae19) Deployment Manager list view showing the deployment table with a search bar, building filter, and New Deployment button ### Row actions Each deployment row has a three-dot menu with the following options: * `View Details` -- View the full list of target buildings and deployment status * `Edit` -- Modify deployment configuration * `Delete` -- Remove the deployment ## Deploy a new dashboard > [!WARNING] > > **Deployment risk:** Deployed dashboards retain the data filters, chart configurations, and settings defined on the host building's dashboard. If the target buildings do not contain the same data, equipment, naming conventions, or configuration, some charts may return errors or no data. Before deploying, confirm that all selected buildings support the dashboard's requirements. **1. Start a new deployment** Select `New Deployment` from the deployment list view. **2. Configure the deployment source** Enter a `Deployment name` and an optional `Deployment description`. Select the source `Building` and the `Dashboard` you want to deploy, then select `Next`. ![New Deployment wizard step 1 Deployment Source showing Deployment name field, Deployment description field, Building dropdown, and Dashboard dropdown with Close and Next buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-source.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=9e67854624dee93575445f09646df692) Deployment Source step showing name, description, building, and dashboard fields **3. Set dependencies** Select which dependencies to validate against the target buildings. The system checks that each target building has the required data sources and ontology points. If the dashboard has no dependencies, the step displays "No dependencies available." Select `Next` to continue. ![New Deployment wizard step 2 Set Dependencies showing Select which dependencies to validate against selected buildings message, a search field, and No dependencies available text with Back, Close, and Next buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-dependencies.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2be8f144ef9b0633e3e588f6b141eb02) Set Dependencies step showing a search field and the dependencies validation area **4. Configure canonicals and fields** Select a `Canonical Type` and `Ontology Fields` to verify which types and fields are compatible with your target buildings. Use the searchable dropdown to filter canonical types such as `cav`, `vav`, `ahu`, `fcu`, `boiler`, `chiller`, `heatPump`, `pump`, and others. This step is optional. Select `Next` to continue. ![New Deployment wizard step 3 Canonicals and Fields showing Canonical Types dropdown expanded with cav, vav, ahu, fcu, uh, boiler, chiller, heatPump, pump, boosterPump, and fan options, and an Ontology Fields dropdown](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-canonicals.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=c1110c1e7688b40fd135c1409e435f29) Canonicals and Fields step showing the Canonical Types dropdown with device types **5. Select deployment targets** Choose the buildings where the dashboard should be deployed. Use the `Deploy To` dropdown to search and select specific buildings, or select all buildings in your portfolio. Select `Next` to continue. ![New Deployment wizard step 4 Deployment Target showing Deploy To with a Select targets dropdown and a Please select deployment targets to configure dependencies message with Back, Close, and Next buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-target.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=7d65ded3c6195eb596a598fcdc3e96ea) Deployment Target step showing the Deploy To dropdown for selecting target buildings **6. Add collaborators** Add collaborators who can view and edit this deployment. Search for users and select `+ Add Users` to add them. The table shows each collaborator's name and role. This step is optional. Select `Next` to continue, or select `Deploy Now` to skip the remaining steps and deploy immediately. ![New Deployment wizard step 5 Collaborators showing a Search for User field, Add Users button, a table with Name and Role columns displaying No collaborators found, and Back, Close, Deploy Now, and Next buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-collaborators.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=a212d0bc2257717afbefd1f3d1d30899) Collaborators step showing the user search field and collaborators table **7. Add to a collection** Choose a collection to organize the deployed dashboard. Use the `Collections` dropdown to select an existing collection. This step is optional. Select `Next` to continue, or select `Deploy Now` to deploy immediately. ![New Deployment wizard step 6 Add to Collection showing a Collections dropdown set to Choose a Collection with Back, Close, Deploy Now, and Next buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-collection.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8d5bf59ef321f2523154a5db0def4638) Add to Collection step showing the Collections dropdown **8. Review and deploy** Review the deployment summary. Confirm all settings are correct, then select `Deploy`. ## Manage existing deployments ### View details Open the three-dot menu on a deployment row and select `View Details`. The Deployment Details panel opens on the right, showing the deployment name, source building, source dashboard, collection, and collaborators. Below the summary, the `Manage Deployments` section lists all target buildings with the deployer name, deployment timestamp, and icons to open or remove each building. ![Deployment Details panel showing Deployment Name Override Report, Source Building KODE 1420 Office, Source Dashboard Overrides, Added to Collection Not added to any collection, Collaborators No collaborators, and Manage Deployments section showing Deployed in 14 of 15 with a searchable list of buildings including Headquarters, Redford Branch, Grand Rapids Branch, Tech Center, Retail Demo, One Financial Plaza, Harbor View Tower, and Meridian Business Center each with open and remove icons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-details.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=29b685ba4c0c241cf4837cc4085f55fc) Deployment Details panel showing deployment summary and the list of target buildings ### Edit a deployment Open the three-dot menu on a deployment row and select `Edit`. The Edit Deployment dialog has two tabs: `Deployment Details` and `Deployment Target`. Update the deployment name, description, source building, or dashboard on the Details tab. Switch to the Target tab to modify target buildings. Select `Update` to save your changes. ![Edit Deployment dialog showing Deployment Details and Deployment Target tabs, Deployment name set to Deployment Test, Deployment description field, Building set to Scodra Nexus, Dashboard set to RWS, and Close and Update buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-edit.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=224c390b1b87dc27fd7dced30ecaa463) Edit Deployment dialog showing the Deployment Details tab with name, description, building, and dashboard fields The `Deployment Target` tab lets you update where the dashboard is deployed and verify target dependencies. Set the `Deploy To` field to select buildings, then review `Target Dependencies` under the `Datasources & Metrics` and `Canonicals & Fields` tabs. Buildings are categorized as `All Buildings`, `Compatible`, `Incompatible`, or `Partial` based on whether they meet the dashboard requirements. ![Edit Deployment dialog showing the Deployment Target tab with Deploy To set to All, Target Dependencies section with Datasources and Metrics and Canonicals and Fields tabs, filter buttons for All Buildings 0, Compatible 0, Incompatible 0, and Partial 0, and a table with Building, Status, and Fields columns](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-edit-target.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=5bbf24116df977d3384d19d6663f6d31) Edit Deployment dialog showing the Deployment Target tab with Deploy To field and Target Dependencies ### Delete a deployment Open the three-dot menu on a deployment row and select `Delete`. Confirm the deletion when prompted. > [!WARNING] > > Deleting a deployment does not remove dashboards already deployed to target buildings. It only removes the deployment record. ## Predefined and custom views ### Predefined view A predefined view is the portfolio-controlled version of a deployed dashboard. When you publish a new version of the source dashboard, all buildings with the predefined view receive the update automatically. Predefined dashboards display a `Predefined` chip next to the dashboard name. The status dropdown shows `Predefined` with a checkmark and provides access to `Version History`. Filter-only changes on a predefined dashboard do not break sync. Edits beyond filter values unlink that site from the source. Building BI warns before you enter edit mode. Once unlinked into a custom view, that site no longer receives predefined updates until you delete the custom view and revert. ![Overrides dashboard at KODE 1420 Office showing a Predefined chip with a dropdown displaying Predefined with a checkmark and Version History with an external link icon, Customize Dashboard and Edit Dashboard buttons, and dashboard widgets including Overridden Points By Device Type donut chart, Overridden Points By Point Type bar chart, and Devices Overridden Points table](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-predefined-view.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=4a30e40e023c4cb4ed59b941867fd50f) Predefined dashboard showing the Predefined chip and status dropdown with Version History option ### Custom view A custom view is a locally editable version of a deployed dashboard for a specific site. Custom views are independent of predefined updates -- changes to the source dashboard do not affect them. To create a custom view: 1. Open the predefined dashboard at the target site. 2. Select `Customize Dashboard`. 3. A confirmation dialog appears. Select `Yes, publish` to publish your custom version. Other dashboards are not affected. ![Publish dashboard dialog stating This will publish your custom version of the dashboard and Other dashboards will not be affected with Cancel and Yes publish buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-publish-custom.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=b2c897b1c2d2a1d16484dbd51782979b) Publish dashboard confirmation dialog when customizing a predefined dashboard The dashboard displays a `Custom` chip after customization. You can edit the custom view like any other dashboard, with the full Chart List, edit toolbar, and all styling options available. Use `Delete Custom` to revert to the predefined version, `Save as Draft` to save privately, or `Publish` to push your custom changes live. ![Overrides dashboard in Custom Draft edit mode showing the Custom chip, timezone selector, Auto Refresh, Mobile Layout, Delete Custom, Cancel, Save as Draft, and Publish buttons at the top, the dashboard widgets on the canvas, and the Chart List panel on the right with Bar, Horizontal Bar, Stacked Bar, Stacked Horizontal Bar, Combo, Line, Line Area, Stacked Line, Pie, Sunburst, Multi-Row Card, and Card chart types](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-deploy-custom-view.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=744d67baf0bbee13d58a79a3ae12328f) Custom view in edit mode showing the Custom chip, Delete Custom button, and Chart List panel > [!TIP] > > Use custom views only when a specific site requires a layout or data configuration that differs from the portfolio standard. This keeps maintenance overhead low. ## Enable the Deployment Manager To grant access to the Deployment Manager: 1. Navigate to Launchpad > `Apps` > `Cloud BMS` > `Roles`. 2. Enable `Deployment Manager Read/Write` under the Building BI module. > [!NOTE] > > Only users with the appropriate role permission can create, edit, or delete deployments. Read-only access allows viewing deployment details without modification. ## Best practices * Test dashboards thoroughly at a single site before deploying across the portfolio. * Use collections to group related deployments for easier management. * Limit custom views to sites that genuinely need different configurations. * Audit deployments periodically to remove outdated or failed entries. ## Related reading > [card] [Collections](/products/building-bi/collections) > > Control visibility and organize dashboards by audience. > [card] [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment) > > Choose independent copies or governed portfolio parity. > [card] [Template types](/products/building-bi/reference/template-types) > > Compare collection, dashboard, page, and chart templates. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboards and manage predefined versus custom views. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts, tables, and widgets. > [card] [Collections](/products/building-bi/collections) > > Organize dashboards into shared groups with role-based access control. # KODE glossary Source: https://docs.kodelabs.com/products/building-bi/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # What is Building BI? Source: https://docs.kodelabs.com/products/building-bi/overview Create interactive dashboards and data visualizations to monitor building performance and share insights across your portfolio. Building BI is the analytics and visualization module in Cloud BMS. Create single-pane-of-glass dashboards that consolidate metrics, support operational workflows, and highlight trends across your entire building portfolio A single dashboard can combine FDD (Fault Detection and Diagnostics monitors equipment and detects operational issues in real time.) results, FTT (Functional Testing Tool runs automated tests on HVAC equipment such as AHUs, VAVs, and FCUs.) scores, energy data, and graphics. You can also include [AssetOps](/products/assetops/quickstart/overview) insights and live sensor readings in one view. Open Building BI from the Cloud BMS portfolio or building sidebar. Design dashboards so users find what they need without leaving the view. See [The philosophy of Building BI](/products/building-bi/concepts/philosophy). > [!NOTE] > > Building BI replaces the legacy `Dashboard` module in Cloud BMS. If you still see the old `Dashboard` module in your navigation, switch to Building BI for the full feature set. ## Start here Pick a path based on what you need first. > [card] [Build your first dashboard](/products/building-bi/tutorials/build-your-first-dashboard) > > Create, configure, and publish a dashboard in one guided session. > [card] [Dashboards](/products/building-bi/dashboards) > > Work with charts, tables, widgets, filters, and sharing. > [card] [Data sources](/products/building-bi/data-sources) > > Connect tables, columns, and metrics that power your charts. > [card] [Collections](/products/building-bi/collections) > > Group dashboards and share them with roles across your team. ## Portfolio and building scope Building BI works at two levels: portfolio (Cross-building scope across every site in your estate. Use it for portfolio analytics and site-to-site comparison.) and building (Scope limited to a single building after you select a site. Use it for day-to-day operations.). The interface and features match at both levels. Only the data scope changes. * **Portfolio level** — Cross-building analytics, aggregated metrics, and site-to-site comparisons. Executives and portfolio managers use this view most often. * **Building level** — Data filtered to one site for monitoring, targeted workflows, and deep-dive analysis. Building operators and facility managers use this view for daily work. Design each dashboard for the altitude where people will open it. A portfolio comparison can look empty at a single building. A building-ops layout can look incomplete at portfolio level. > [!NOTE] > > Some features appear only at the portfolio level. [`Deployment Manager`](/products/building-bi/deployment-manager), for example, is available only when you open Building BI from the portfolio view. Organizations can also limit users to specific buildings through role permissions. See [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ## Enable Building BI Enable Building BI per building in [Launchpad](/products/launchpad/get-started/introduction). After the module is on, assign role permissions so users can open and edit dashboards. See [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). **1. Open the building** In Launchpad, go to `Buildings` and select the building where you want Building BI. **2. Open Modules** Select the `Modules` tab. **3. Enable Building BI** Find `Building BI` in the module list and turn the toggle on. ![Launchpad Buildings flow opening a building Modules tab and turning on the Building BI module toggle](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-enable-building-module.gif?s=20dca7494274f17d99cf21a05d12c352) Enabling Building BI on a building Modules tab in Launchpad > [!TIP] > > KODE Support often enables Building BI for your organization. If you cannot access building modules, contact [support@kodelabs.com](mailto:support@kodelabs.com) or ask your customer success manager (CSM). ## Access Building BI Select `Building BI` from the left navigation bar. The module opens to your dashboard view. The left-hand navigation panel is the primary way to move through Building BI. It has two sections. **Top section** * [`Collections and Dashboards`](/products/building-bi/collections) — Opens the management page where you edit collections and dashboards, including configuration, settings, and permissions. * Collections list — Expandable groups (A role-based grouping of dashboards, similar to a folder. One dashboard can belong to multiple collections.) of dashboards by topic or team. Select the arrow next to a collection name to expand or collapse it. Visibility depends on your KODE OS role. Editing a dashboard in one collection updates it everywhere it appears. * `My Dashboards` — Dashboards you created or can edit as a collaborator, across every collection. Unlike collections, access here is assigned per user. See [My Dashboards](/products/building-bi/collections#my-dashboards). **Bottom section** * [`Deployment Manager`](/products/building-bi/deployment-manager) — Deploy a dashboard or collection across multiple buildings at once. Portfolio level only. Highly customized dashboards may not scale well across sites. * [`Settings`](/products/building-bi/settings) — Manage shared links, scheduled reports, and custom color palettes. * [`Data Sources`](/products/building-bi/data-sources) — Add, edit, or remove tables, columns, and metrics available across your Building BI instances. * [`Templates`](/products/building-bi/templates) — Create, import, or export templates for collections, dashboards, tabs, or widgets. This section also includes global templates with standard KODE Labs dashboards. > [!WARNING] > > Changes made through the bottom navigation tools (`Data Sources`, `Settings`, `Templates`) affect the entire portfolio, not just the current building. You can collapse the panel when you need more canvas space. > [!TIP] > > Select the `<` icon at the top of the navigation panel to maximize your dashboard viewing area. ## Key features Building BI provides tools to create, manage, and distribute visualizations across your portfolio. * **[Dashboards](/products/building-bi/dashboards)** — Build interactive views with configurable widgets (Customizable components on a dashboard canvas, such as charts, slicers, cards, tables, and graphics.), charts, and data tables. * **[Collections](/products/building-bi/collections)** — Organize dashboards into groups and control access with role-based sharing. * **[Data sources](/products/building-bi/data-sources)** — Connect dashboards to live building data from devices, points, and other KODE OS modules. * **[Deployment manager](/products/building-bi/deployment-manager)** — Deploy a dashboard configuration across multiple sites at once. * **[Templates](/products/building-bi/templates)** — Duplicate collections, dashboards, tabs, or widgets for faster reuse. * **[Widget customization](/products/building-bi/widget-customization)** — Style and configure individual widgets on the canvas. * **[PDF exports](/products/building-bi/pdf-exports)** — Generate scheduled PDF reports and distribute them to stakeholders. * **[Version history](/products/building-bi/concepts/draft-mode-version-history)** — Track dashboard changes over time and restore earlier versions when needed. * **[Settings](/products/building-bi/settings)** — Configure sharing, scheduled reports, and color palettes. ## How these docs are organized Building BI docs follow the product, not documentation labels. * **Get started** — This overview, plus a **Tutorials** group for guided walkthroughs such as the [first-dashboard tutorial](/products/building-bi/tutorials/build-your-first-dashboard). * **Feature groups** — [Dashboards](/products/building-bi/dashboards), [Data sources](/products/building-bi/data-sources), [Collections](/products/building-bi/collections) and [templates](/products/building-bi/templates), and [Administration](/products/building-bi/settings). * **Concepts** — Why and how the product works, starting with [philosophy](/products/building-bi/concepts/philosophy). * **Reference** — Field-level lookups and the [glossary](/products/building-bi/glossary). If you know what you need, use search. If you are learning the product, start with the tutorial, then open the matching topic page. ## Next steps > [card] [Build your first dashboard](/products/building-bi/tutorials/build-your-first-dashboard) > > Walk through creating, configuring, and publishing a dashboard in one session. > [card] [The philosophy of Building BI](/products/building-bi/concepts/philosophy) > > Learn the design mindset behind dashboards that fit real workflows. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Roll out dashboards and collections across buildings in your portfolio. > [card] [Building BI settings](/products/building-bi/settings) > > Configure shared links, scheduled reports, and color palettes. # PDF exports and scheduled reports Source: https://docs.kodelabs.com/products/building-bi/pdf-exports Export dashboards as PDF files and schedule automated PDF reports for recurring delivery to team members. Building BI lets you export dashboards as PDF files and schedule automated reports for recurring delivery. Use PDF exports for one-time snapshots. Use scheduled reports for ongoing distribution. > [!NOTE] > > As an alternative to a static PDF, you can also share a live, interactive dashboard or widget with a [shareable link](/products/building-bi/dashboards#share-dashboards-and-widgets). Use a link when recipients need to explore data, not just read a PDF snapshot. > [accordion] More info on Shareable links > > A shareable link lets people view and interact with a dashboard without a normal KODE OS session. From the dashboard three-dot menu, select `Share`. Set pages, expiration, link title, refresh rate, and allowed IP addresses, then generate the link. > > Recipients get a read-only interactive view. They can use charts and filters but cannot edit the dashboard. You can also share an individual widget from its three-dot menu. > > For full steps, see [Share dashboards and widgets](/products/building-bi/dashboards#share-dashboards-and-widgets). For field details, see [Shared links and scheduled reports](/products/building-bi/reference/shared-links-scheduled-reports). Manage links portfolio-wide in [Building BI settings](/products/building-bi/settings#shared-links). ## Export a dashboard as PDF **1. Open the export dialog** Navigate to the dashboard you want to export. Select the three-dot menu in the top-right corner and choose `Export`. ![Operations Dashboard in Published state showing the three-dot menu with Share, Deploy, Export, Version History, and Schedule PDF Report options](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-actions-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8609ea4442695f5e6e6b5c8dcaf50b6d) Dashboard three-dot menu showing Share, Deploy, Export, Version History, and Schedule PDF Report options **2. Configure export settings** Set the following options: | Field | Description | | - | - | | **File Name** | The name for the exported PDF file | | **Pages** | Select `All Pages` or choose specific pages to include | | **Export data with current filter modifications** | Include data reflecting any active dashboard filters. See [filter options](/products/building-bi/reference/filter-options). | ![Export Dashboard as PDF dialog showing File Name set to 2026-05-15 Operations Dashboard, All Pages radio selected, Select Pages option, Export data with current filter modifications checkbox checked, and Cancel and Export buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-export-pdf-dialog.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=75889a193f76cdce9af631616128625c) Export Dashboard as PDF dialog with file name, page selection, and filter options **3. Download the PDF** Select `Export`. The file downloads automatically once processing completes. > [!NOTE] > > Processing time depends on the dashboard size and complexity. Larger dashboards with many widgets take longer to generate. > [!WARNING] > > Pinned dashboard filters are not included in PDF exports. The exported PDF reflects the dashboard data without any pinned filter modifications applied at the time of export. > > PDF export uses the saved [dashboard parameter](/products/building-bi/dashboards#dashboard-parameters) values. A viewer's temporary what-if is not included. ## Schedule a PDF report Scheduled reports automatically send dashboard PDFs to specified recipients on a recurring basis. **1. Open the schedule dialog** Navigate to the dashboard and select the three-dot menu. Choose `Schedule PDF Report`. The dialog has two tabs: `Create Schedule` and `Schedules`. **2. Configure the report** On the `Create Schedule` tab, complete the following fields: ![Schedule PDF Report dialog showing Create Schedule tab with Name, Pages set to All pages selected, Subject, Export data with current filter modifications checked, From date, Time, Timezone set to UTC, Frequency, Recipients, Ends set to Never, and Cancel and Schedule buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-schedule-pdf.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=db9ad4b12d30ac59ef38234dfc6f01b8) Schedule PDF Report dialog showing the Create Schedule tab with all configuration fields **Name** `Field` Enter a descriptive name for the scheduled report. **Pages** `Field` Select which dashboard pages to include. Choose `All pages selected` to export every page, or pick specific pages. **Subject** `Field` Set the email subject line for the report. **Export data with current filter modifications** `Toggle` When enabled, the exported PDF reflects the current dashboard filter state. **From / Time / Timezone** `Field` Set the first delivery date, time of day, and timezone. Later sends follow this start time on the chosen frequency. **Frequency** `Field` Choose how often the report repeats after the start time (for example, daily, weekly, or monthly). **Recipients** `Field` Add email addresses for users who should receive the report. **Ends** `Field` Choose `Never` for an indefinite schedule, or `On` to set an end date. **3. Activate the schedule** Select `Schedule` to activate the recurring report. > [!NOTE] > > Only users with a KODE Labs account can be added as recipients. Scheduled report emails include both a PDF attachment and a live link to the dashboard. Recipients can use the PDF for a quick review and follow the link for further investigation with interactive filters and real-time data. ## Manage scheduled reports Select the `Schedules` tab in the Schedule PDF Report dialog to view all active report schedules. The table lists each schedule with its name, frequency, active status, and end date. Use the toggle to enable or disable a schedule, or select the three-dot menu to `Edit` or `Delete` it. ![Schedule PDF Report dialog showing the Schedules tab with a table listing Monthly Report with Weekly frequency, an Active toggle enabled, no end date, and a three-dot menu with Edit and Delete options](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-schedule-list.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8764954d63bb374367882e4920086977) Schedules tab showing a list of scheduled reports with name, frequency, active toggle, and end date ## Related reading > [!NOTE] > > Manage schedules in [Building BI settings](/products/building-bi/settings). For field-level details, see [Shared links and scheduled reports](/products/building-bi/reference/shared-links-scheduled-reports). For who can share or schedule, see [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). ## Next steps > [card] [Share dashboards and widgets](/products/building-bi/dashboards#share-dashboards-and-widgets) > > Create shareable links for live, interactive dashboard or widget views. > [card] [Settings](/products/building-bi/settings) > > Manage shared links and scheduled reports from the Building BI settings page. # Accessibility in Building BI Source: https://docs.kodelabs.com/products/building-bi/reference/accessibility/overview How Building BI supports keyboard navigation, screen readers, table views of chart data, and accessible color choices. Building BI meets the KODE Labs accessibility standard across dashboards, widgets, data sources, templates, and settings. Accessibility is built in. There is no separate mode to turn on. For platform-wide keyboard and screen-reader guidance, see [Accessibility in KODE OS](/products/kode-os/accessibility). ## What is covered Every Building BI area uses accessible interface components: * Dashboard list and collections * Desktop layout in view mode and edit mode * Mobile layout and the mobile view * Public view for shared dashboards * Charts, widget setup, and widget styles * Data sources, templates, Deployment Manager, and Settings Existing dashboards, layouts, and workflows work the same way for every user. ## View chart data as a table Chart widgets offer a `View as table` option in the widget three-dot menu. It opens the chart’s categories, series, and values as a semantic HTML table built from the same result set as the chart. Use it when you need exact values or want to read chart data with a screen reader. Building BI renders the table with accessible headers, and you can navigate it with the keyboard. `View as table` is available on chart types such as Bar, Line, Pie, Combo, Heatmap, and Time Series. For the full list and steps, see [View chart data as a table](/products/building-bi/reference/accessibility/view-chart-as-table). ## Keyboard navigation Standard KODE OS keyboard controls work throughout Building BI: | Key | Action | | - | - | | Tab | Move to the next widget, control, or menu item | | Shift + Tab | Move to the previous interactive element | | Enter or Space | Open a menu, select a control, or activate a link | | Arrow keys | Move within menus, tabs, option lists, and tables | | Escape | Close an open menu, dialog, or panel | A visible focus indicator shows which element is selected. In edit mode, additional shortcuts let you select and bulk-edit widgets. See [Keyboard shortcuts](/products/building-bi/reference/keyboard-shortcuts). ## Screen readers Building BI components expose meaningful labels, page structure, control states, and status announcements to screen readers. Chart widgets are visual by nature. To read the underlying data, use `View as table`. The table exposes row and column headers so a screen reader can announce each value in context. > [!NOTE] > > Screen-reader behavior can vary by browser, operating system, and assistive technology. Start your screen reader before you open Building BI. ## Color and contrast Building BI interface components use strong color contrast and clear focus indicators. Information in the interface does not rely on color alone. When you choose colors for charts, you control contrast and color-blind discernibility. Keep dashboards readable for every viewer: * Verify that series colors remain distinguishable for people with color vision deficiency. * Confirm that data labels and legend text keep sufficient contrast against their background. * Add data labels or reference lines so values do not depend on color alone. > [!TIP] > > Use a contrast checker and a color blindness simulator before you publish a palette. Custom palettes are managed in `Settings`. See [Color tools](/products/building-bi/reference/color-tools). ## Report an accessibility issue If you encounter an accessibility barrier in Building BI, contact KODE Labs Support. Include the dashboard or page, what you were trying to do, what occurred, your browser and operating system, and any assistive technology you were using. A screenshot or screen recording helps the team investigate. ## Next steps > [card] [View chart data as a table](/products/building-bi/reference/accessibility/view-chart-as-table) > > Open a chart’s data as a semantic table from the widget menu. > [card] [Keyboard shortcuts](/products/building-bi/reference/keyboard-shortcuts) > > Select and bulk-edit widgets while editing a dashboard page. > [card] [Color tools](/products/building-bi/reference/color-tools) > > Manage palettes and check color-blind discernibility and contrast. > [card] [Accessibility in KODE OS](/products/kode-os/accessibility) > > Platform-wide keyboard, screen-reader, and visual accessibility guidance. # View chart data as a table Source: https://docs.kodelabs.com/products/building-bi/reference/accessibility/view-chart-as-table Switch a supported Building BI chart widget to a semantic table that shows the same categories, series, and values. `View as table` opens a chart’s categories, series, and values as a semantic HTML table from the same result set the chart already uses. Use it from the widget three-dot menu on [supported chart types](#supported-chart-types) such as Bar, Line, and Pie when you need exact values or assistive-technology access without exporting or rebuilding the visualization. Open View as table from a chart widget three-dot menu ## View a chart as a table **1. Open a dashboard with a supported chart** Open the dashboard that contains the chart. The chart must be configured and showing data. **2. Open the widget menu** On the chart widget, open the three-dot menu. **3. Select View as table** Select `View as table`. The chart data appears as a structured table. You can read the same categories, series, and values without relying on the visual chart or tooltips. ## How the table relates to the chart The table is generated from the same result set the chart already uses. You do not change the chart’s query, filters, or configuration when you open table view. The table presents categories, series, and values in a structured format. Chart and table values stay aligned, with no rounding or formatting drift between views. Building BI renders the table with semantic HTML and accessible headers so assistive technologies can interpret the data. You can also navigate the table with the keyboard. ## Supported chart types `View as table` is available for these chart types: * [Bar](/products/building-bi/reference/chart-types#bar) * [Horizontal Bar](/products/building-bi/reference/chart-types#horizontal-bar) * [Stacked Bar](/products/building-bi/reference/chart-types#stacked-bar) * [Horizontal Stacked Bar](/products/building-bi/reference/chart-types#horizontal-stacked-bar) * [Line](/products/building-bi/reference/chart-types#line) * [Line Area](/products/building-bi/reference/chart-types#line-area) * [Stacked Line](/products/building-bi/reference/chart-types#stacked-line) * [Pie](/products/building-bi/reference/chart-types#pie) * [Combo](/products/building-bi/reference/chart-types#combo) * [Sunburst](/products/building-bi/reference/chart-types#sunburst) * [Treemap](/products/building-bi/reference/chart-types#treemap) * [Tree](/products/building-bi/reference/chart-types#tree) * [Heatmap](/products/building-bi/reference/chart-types#heatmap) * [Scatter](/products/building-bi/reference/chart-types#scatter) * [Advanced Scatter](/products/building-bi/reference/chart-types#advanced-scatter) * [Boxplot](/products/building-bi/reference/chart-types#boxplot) * [Horizontal Boxplot](/products/building-bi/reference/chart-types#horizontal-boxplot) * [Polar Bar](/products/building-bi/reference/chart-types#polar-bar) * [Stacked Polar Bar](/products/building-bi/reference/chart-types#stacked-polar-bar) * [Time Series](/products/building-bi/reference/chart-types#time-series) * [Timeline](/products/building-bi/reference/chart-types#timeline) * [Sankey](/products/building-bi/reference/chart-types#sankey) Other widget types, including dedicated table widgets, are outside the scope of this feature. For Setup requirements per type, see [Chart types](/products/building-bi/reference/chart-types). ## Limits `View as table` does not replace the dedicated Table widget. It does not turn the chart into a spreadsheet. Advanced grid features such as multi-sort, column selection, and inline editing are out of scope. Only [supported chart types](#supported-chart-types) show the `View as table` option. ## Next steps > [card] [Widget customization](/products/building-bi/widget-customization) > > Configure widgets and use the chart three-dot menu. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Review Setup requirements for each Building BI chart type. > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Decide when a chart or a table widget fits the question. > [card] [Dashboards](/products/building-bi/dashboards) > > Build and publish dashboards that include chart widgets. # Calculated fields Source: https://docs.kodelabs.com/products/building-bi/reference/calculated-fields Calculated columns, metrics, and URLs you can add to a Building BI data source, including how to create them, data types, and visibility options. Calculated fields add custom logic to a [data source](/products/building-bi/data-sources): calculated columns, calculated metrics, and calculated URLs. SQL must match the source database dialect — [PostgreSQL](https://www.postgresql.org/docs/current/), [ClickHouse](https://clickhouse.com/docs/sql-reference), or [BigQuery](https://cloud.google.com/bigquery/docs/reference/standard-sql/query-syntax). For worked expressions, Real-Time metadata syntax, and examples, see [Calculated columns, metrics, and URLs](/products/building-bi/data-sources#calculated-columns-metrics-and-urls). > [!WARNING] > > Editing a calculated column, metric, or URL affects all dashboards portfolio-wide. Always validate logic before you apply changes. Native columns cannot be edited. They are the building blocks that calculations reference. ## Add a calculated field You can create a calculated field from Building BI `Data Sources` or from a chart in the dashboard editor. Both paths open the same `Add Column` form. > [!NOTE] > > Open `Data Sources` from the bottom of the Building BI left navigation tray. Do not use the KODE OS `Data Sources` button. That page manages connectors, not Building BI tables. See [Data source types](/products/building-bi/reference/data-source-types). ### From Data Sources **1. Open Building BI Data Sources** In Building BI, select `Data Sources` at the bottom of the left navigation tray. **2. Open the data source** Select the data source you want to extend. **3. Start a new field** Select `+ Add Column` in the upper right of the schema view. **4. Complete the field details** Choose the field type, then set name, display name, description, data type, and SQL expression. Optionally enable `Hidden` or `Sensitive Values` on the field. | Field | Description | | - | - | | Type | `Calculated`, `Metric`, or `URL`. | | Name | Unique identifier within the data source. Use this name in SQL and chart configuration. | | Display name | Label shown in Building BI. Can differ from `Name`. | | Description | Optional summary of the field's purpose. | | Data type | Number (`DOUBLE_VALUE`), String, Date or DateTime, or Boolean. Required for calculated columns and metrics. | | SQL expression | Logic for the field, written in the database dialect of the source. | | `Hidden` | Hides the field from the available columns list in Building BI. | | `Sensitive Values` | Shows the column name instead of the value. Sensitive fields do not transfer when you [template](/products/building-bi/templates). | ![Add Column dialog with Calculated selected, Name and Display Name fields, Description, Data Type dropdown, SQL Expression editor, and Create button](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-calculated-fields-add-form.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=3d0a1e8bba9fd9ef6264403e520149fe) Add Column form for a calculated field on a Building BI data source For schema tabs, samples, and SQL examples, see [Data sources](/products/building-bi/data-sources#calculated-columns-metrics-and-urls). ### From the chart editor While editing a chart, open Chart Parameters `Setup` and select `+ Add Column` (or the `+` control next to a field group such as Metrics). The same portfolio-wide field form opens. ![Building BI dashboard editor with Chart Parameters Setup open, showing Metrics with formula indicators and the control to add a new calculated field](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-calculated-fields-add-editor.gif?s=c0e0aac3da54c219a8c7a8d95991cbc6) Adding a calculated field from Chart Parameters Setup while editing a dashboard You cannot edit an existing calculated field's SQL from the chart `fx` popup. Open the field from `Data Sources` to change the expression. See [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters). ## Calculated columns Calculated columns work like spreadsheet formulas. They apply logic to each row using only that row's data. Common patterns include extracting time parts (for example, `toHour(date_time_local)`) and isolating one sensor with conditional logic. Use exact database column names (for example, `building_name`, not `"Building Name"`). See [Point time series column reference](/products/building-bi/data-sources#column-reference). On Point Time Series Real-Time (ClickHouse), wrap metadata fields such as `building_name`, `device_name`, or `ontology_point_field` in `dictGetString(...)`. Last Value tables do not need the wrapper. | Table | Metadata syntax required? | | - | - | | Point Time Series Real-Time (ClickHouse) | Yes — wrap metadata fields in `dictGetString(...)`. | | Point Time Series Last Value (Virtual) | No — reference the metadata column directly. | Copy-ready Real-Time and Last Value examples are in [Data sources](/products/building-bi/data-sources#calculated-columns-metrics-and-urls). For why the tables differ, see [Real-Time vs Last Value](/products/building-bi/data-sources#key-data-sources). ## Calculated metrics Calculated metrics aggregate across multiple rows. The output recalculates based on the chart's grouping (for example, per hour or per device). You can filter inside the expression (for example, `sumIf`) or keep the metric simple and filter on the chart. See [Filter options](/products/building-bi/reference/filter-options) and worked examples in [Data sources](/products/building-bi/data-sources#calculated-columns-metrics-and-urls). As an alternative to a chart filter, put the condition in a single metric. For example: ```sql theme={"theme":{"light":"github-light","dark":"github-dark"}} avgIf(number_value, device_name = 'AHU_2') ``` That metric returns the average only for matching rows. You do not need a separate chart filter for that device. Set a data type on every calculated metric. Non-Number metrics change where you can use the field: | Area | Behavior | | - | - | | Charts that need a numeric metric | String, DateTime, and Boolean metrics cannot be the metric in Bar (all), Line (all), Pie, Sunburst, Tree-map (primary metric), Boxplot, Scatter, Advanced Scatter, Gauge, Sankey, Slicer, Polar (all), or Heat-map. In Time-series they may appear in the tooltip only. See [Chart types](/products/building-bi/reference/chart-types). | | Top N filter | Only Number metrics (`DOUBLE` or `INT`) can be used in the Top N metric section. | | Formatting | String, Date, and Boolean metrics used as a table column or in a Number widget get type-appropriate formatting (for example, prefix or suffix for strings). | | Metric filters | Adapt to the metric's data type. See [Filter options](/products/building-bi/reference/filter-options). | ## Calculated URLs Calculated URLs turn row data into navigation actions. | URL type | Behavior | | - | - | | Internal | Pattern such as `/buildings/{building_id}`. Built automatically; validates IDs; navigates within KODE OS on desktop and mobile. | | External | Opens in a new tab to an external resource (for example, a CMMS or a specific work order). | To apply a URL on a table column, open the widget Style settings. Set the column's URL option (for example, `Device URL`) so each cell becomes a hyperlink to that record's page. See [Widget customization](/products/building-bi/widget-customization). Returned URL columns appear in the response prefixed with `INTERNAL_URL::` (for example, `INTERNAL_URL::building_url::building_name`). ### URLs on chart widgets You can assign a single URL column (`urlColumn`) to a dimension, breakdown dimension, hierarchy item, or the Time-series Key column. On charts with a URL applied, right-click a data point to open a context menu. The menu offers navigation to the linked KODE OS record (Building, Area, Device, and similar) and cross-filtering. Supported on Tables (Raw, Aggregated, Pivot), Bar (all), Line (all, at marker points), Pie, Sunburst, Heat-map, Tree-map, Scatter, Boxplot, Sankey (nodes only), Polar Bar (all), and Time-series. Chart definitions are in [Chart types](/products/building-bi/reference/chart-types). ## Columns vs metrics Calculated URLs create links. Columns and metrics are easier to confuse: columns run once per row; metrics aggregate across rows. | Feature | Calculated columns | Calculated metrics | | - | - | - | | Scope | Single row | Multiple rows | | Function | Applies logic to create a new virtual field | Aggregates data (`SUM`, `AVG`, `COUNT`, and similar) | | Behavior | Independent; does not aggregate | Recalculates based on chart grouping | The graphic below shows a calculated column that labels comfort on every row from that row's temperature. ![Graphic showing a calculated column Temp Comfort that labels each discharge air temperature row as Too Cold, Comfortable, or Too Hot using per-row CASE logic](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-calculated-fields-column.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=76e7a9ec04b2b2f9781b5845c5f507af) A calculated column evaluates each row and writes a result for that row A calculated metric instead collapses many rows into one aggregated value for the chart. ![Graphic showing a calculated metric that averages temperature values for AHU 2 filtered on the dashboard, producing a single card value of 69.5 degrees Fahrenheit](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-calculated-fields-metric.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=ef2a4645ae841a5490725afe3990c872) A calculated metric aggregates matching rows into one chart value ## Database and syntax | Table or database | Syntax notes | | - | - | | Real-Time (ClickHouse) | Raw data. Requires [ClickHouse](https://clickhouse.com/docs/sql-reference) syntax and `dictGetString` for metadata. See [Database backends](/products/building-bi/data-sources#database-types). | | Last Value (Virtual) | Pre-processed. Generally easier. No metadata wrapper. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). | | PostgreSQL / BigQuery | Same logic, different phrasing. See [PostgreSQL](https://www.postgresql.org/docs/current/) and [BigQuery](https://cloud.google.com/bigquery/docs/reference/standard-sql/query-syntax). | ### Calculated field limitations Calculated columns and metrics in Building BI do not support: * Window functions * Aggregations of aggregations This is a calculated field limit, not a ClickHouse limit. ClickHouse virtual table SQL can use window functions. Preferred workarounds: put the logic in a [virtual table](/products/building-bi/concepts/physical-vs-virtual-data-sources), or move it to Building Data Hub, for example with a window transformation. ## Parameters in SQL Type `@` in a calculated column, calculated metric, or virtual data source query to insert a [parameter](/products/building-bi/data-sources#parameters). URL columns and actions do not accept parameters. ## See also * SQL examples and metadata patterns: [Data sources](/products/building-bi/data-sources#calculated-columns-metrics-and-urls) * Source and database types: [Data source types](/products/building-bi/reference/data-source-types) * Columns to reference: [Point time series column reference](/products/building-bi/data-sources#column-reference) * Real-Time vs Last Value: [Real-Time vs Last Value](/products/building-bi/data-sources#key-data-sources) * Chart field slots: [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters) * Filters and Top N: [Filter options](/products/building-bi/reference/filter-options) ## Next steps > [card] [Data sources](/products/building-bi/data-sources#calculated-columns-metrics-and-urls) > > Write calculated field SQL, including Real-Time metadata syntax and worked examples. > [card] [Chart types](/products/building-bi/reference/chart-types) > > See which charts accept metrics, columns, and URL navigation. ## Related reading > [card] [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources) > > Compare direct tables with derived virtual sources. > [card] [Key data sources](/products/building-bi/data-sources#key-data-sources) > > Choose Real-Time or Last Value Point Time Series sources. > [card] [Database types](/products/building-bi/data-sources#database-types) > > Understand ClickHouse, PostgreSQL, and BigQuery trade-offs. > [card] [Column reference](/products/building-bi/data-sources#column-reference) > > Look up column names for calculations and filters. # Camera widget Source: https://docs.kodelabs.com/products/building-bi/reference/camera-widget Add a live camera feed to a Building BI dashboard from the Chart List. The **Camera** widget displays a live camera feed on a Building BI dashboard alongside charts and metrics. Add it from the **Chart List** during dashboard edit mode, choose a camera type, connect the feed, and resize or reposition it like any other widget. ## Add a camera widget **1. Enter edit mode** Open the dashboard and select **Edit Dashboard**. **2. Find Camera in the Chart List** In the **Chart List**, search for **Camera**, then drag **Camera** onto the canvas. ![Building BI edit mode with Chart List search set to Camera and the Camera widget ready to drag onto an empty dashboard canvas](https://mintcdn.com/kodelabs/hpe6Pd1K3btC2pO2/images/kode-os/building-bi/bbi-camera-widget-chart-list.png?fit=max\&auto=format\&n=hpe6Pd1K3btC2pO2\&q=85\&s=4a5dfdf8d95ce3016d266609c54ed5cd) Search Camera in the Chart List and drag it onto the dashboard **3. Configure the feed** In **Chart Configuration** on the **Setup** tab, set **Camera Type** to **iFrame**, **URI**, or **Device**. For **iFrame**, paste the stream URL in **Source URL**, then select **Embed**. ![Chart Configuration Setup tab with Camera selected, Camera Type set to iFrame, Source URL paste field, and Embed button](https://mintcdn.com/kodelabs/hpe6Pd1K3btC2pO2/images/kode-os/building-bi/bbi-camera-widget-setup.png?fit=max\&auto=format\&n=hpe6Pd1K3btC2pO2\&q=85\&s=f3ad762737b73adb15b1ae99a05bef00) Camera Setup with Camera Type set to iFrame and Source URL ready to paste | Field | Description | Required? | | - | - | - | | **Camera Type** | How the feed is connected: **iFrame**, **URI**, or **Device** | Yes | | **Source URL** | Stream or page URL to embed when **Camera Type** is **iFrame** | Yes when using iFrame | **4. Publish** Select **Save as Draft** or **Publish** when the layout is ready. ## Widget behavior | Behavior | Detail | | - | - | | **Layout** | Drag to resize and reposition on the dashboard canvas | | **Empty state** | Until you complete Setup, the widget prompts you to select values in the customization menu | | **Live feed** | Shows the connected camera stream when the source is available | | **Offline / error** | Displays a clear empty or error state when the feed is unavailable | > [!TIP] > > Place camera widgets on operational dashboards that combine live video with point trends, alarms, or KPI cards so operators stay in one view. ## Next steps > [card] [Chart types](/products/building-bi/reference/chart-types#camera) > > Find Camera in the Chart List catalogue with other widget types. > [card] [Dashboards](/products/building-bi/dashboards) > > Create and edit dashboards that host camera widgets. > [card] [Widget customization](/products/building-bi/widget-customization) > > Style and arrange widgets on the canvas. # Chart setup parameters Source: https://docs.kodelabs.com/products/building-bi/reference/chart-setup-parameters Configure shared Setup tab controls for Building BI charts: fields, column options, and sort order. The **Setup** tab controls the data a chart shows. The **Style** tab controls presentation — see [Chart styling options](/products/building-bi/reference/chart-styling-options). Per-type fields live in [Chart types](/products/building-bi/reference/chart-types). Every widget needs a data source first. See [Data sources](/products/building-bi/data-sources). ## Field list | Field type | Description | | - | - | | Metrics | Pre-aggregated values. View code with `fx`. | | Columns | Source fields. Some calculated fields also show `fx`. | Edit calculated metrics and columns in the data source — not from the `fx` popup. See [Calculated fields](/products/building-bi/reference/calculated-fields). After you add a column, open `>` to set type-specific options and rename it for viewers. See [Filter options](/products/building-bi/reference/filter-options). **Y-Axis Limits** in Setup override **Min/Max Range** on the Style tab. ## Sorting | Control | Description | | - | - | | Sort toggle (`⇅`) | Changes sort direction for a column | | Sort Order section | Drag to reorder; add columns; set ASC/DESC; remove columns | You can sort by a column the widget does not display. Non-displayed sort columns require an aggregate (treated as a metric while sorting). | Widget type | Can sort by | Cannot sort by | | - | - | - | | Bar, Line, Combo, Pie, Sunburst, Table Aggregated, Polar Bar | Dimensions, breakdowns, metrics, other columns as metrics | — | | Heat-map, Advanced Scatter | X-Axis, Y-Axis, Metric, other columns as metrics | — | | Box-plot | Dimension, Metric, other columns as metrics | Distribute across | | Table Raw | Columns, other columns | Calculated metrics | | Slicer | Slicer column, other columns as metrics | — | | Tree-map | Hierarchy | Primary/secondary metrics, other columns | | Time-series | Keys, Tooltips | Date, Value, other columns | | Timeline | Keys, Tooltips | Start/End Time, Bar Label, other columns | | Table Pivot | (limited) | Columns outside widget configuration | | Card, Number, Gauge, Text, I-Frame, Weather, Navigation, Graphics, Sankey, Scatter | Sort not applicable | — | ## Next steps > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup fields per widget type. > [card] [Add widgets](/products/building-bi/dashboards#add-widgets-and-charts) > > Configure charts on a dashboard. # Chart styling options Source: https://docs.kodelabs.com/products/building-bi/reference/chart-styling-options Look up Style tab options for Building BI widgets, including axes, labels, colors, and chart-type-specific sections. The `Style` tab controls how a widget looks. It never changes the data the chart shows. Configure data in the [Setup tab](/products/building-bi/reference/chart-setup-parameters). For how-to tasks such as default styles, bulk styling, and copy/paste, see [Widget customization](/products/building-bi/widget-customization). Sections available depend on the chart type. `General`, `Colors`, and `Margins` appear on almost every chart. Other sections appear only on types that use them. See [Style options by chart type](#style-options-by-chart-type). Each section has an eye icon that shows or hides it. Color options are covered in depth in [Color tools](/products/building-bi/reference/color-tools). The top of the `Style` tab also includes reusable-style and layout controls: * `Set as Default Style` — saves the current widget styling as the page-level default. * `Apply Default Style` — applies the saved page default to this widget. * `Draggable` — allows repositioning the widget on the canvas. * `Resizable` — allows resizing the widget by dragging its corners. ![Chart Configuration Style tab showing General, X-Axis, Y-Axis, Dynamic Units, Data Labels, Legends, Chart Tooltips, Colors, Scroll, and Margins sections with eye icons and expand arrows on the left, and Set as Default Style and Apply Default Style buttons, Draggable and Resizable toggles, Paddings with Left, Top, Right, Bottom all set to 0 px, Background with Fill Color toggle, and Title section with the title Average Floor Zone Air set, Word wrap checkbox, and Font set to Roboto 14 px with bold, italic, uppercase, underline, and color options on the right](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-style-tab.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=d288b7f45fe5c0bf39ffaeb167e3031e) Style tab showing expandable style sections on the left, and default style buttons, layout toggles, padding, background, and title settings on the right > [!TIP] > > Select multiple widgets by holding Shift and clicking them on the canvas, then change shared style options in bulk. ## General Controls the widget container and layout. **Paddings** `Field` Sets internal spacing around the chart content. Configure `Left`, `Top`, `Right`, and `Bottom` independently in pixels. **Background** `Toggle` Sets the fill color for the widget card. Toggle on to apply a color, or leave off for a transparent background. **Title** `Toggle` Adds a header to the widget. Enter the title text, enable `Word wrap`, and configure font family, size, weight, style, uppercase, underline, and color. Set text alignment to left, center, or right. **Tooltip** `Toggle` Adds an informational tooltip icon to the widget. Enter the tooltip text. Set `Icon Color` and choose `Placement` of `In Header` or `Floating`. Use tooltips for calculated or non-obvious values. **Corner Radius** `Toggle` Controls corner rounding on the widget card. Set `Corner Radius Type` to `All` for uniform corners, or configure each corner. Enter the radius in pixels. **Borders** `Toggle` Adds borders to the widget card. Select `All Borders` or configure individual sides. Set border `Weight` in pixels and choose a color. **Empty State** `Toggle` Controls what the widget shows when no data is returned. Set a custom `Message`. Toggle `Chart Icon` to show or hide the chart type icon. Configure `Background Color`, `Icon Color`, and `Text Color`. **Size and Position** `Field` Sets the widget footprint on the dashboard grid. Use with `Draggable` and `Resizable` to control whether viewers can move or resize it. ## X-Axis and Y-Axis Both axes share the same options. Combo and Line charts add a `Secondary Y-Axis` with the same controls. **Show axis** `Toggle` Shows or hides the whole axis. **Title** `Field` Renames the axis label (for example, "Floor" instead of a raw field name). Set a `Margin` between the title and the axis. Configure font family, size, weight, style, and color. **Values** `Toggle` Formats axis tick labels. * **Font** — family, size, weight, style, and color. * **Margin** — spacing between labels and the chart area. On the Y-Axis, this also sets width for label text. * **Overflow** — controls how long axis labels display (Y-Axis only). `truncate` clips long labels. `break` wraps labels onto multiple lines, splitting at spaces to keep words intact. `breakAll` wraps at any character, filling each line completely before starting the next. Leave unset for full text. * **Interval** — overrides automatic label spacing. Set to `0` to show every label. * **Rotate** — tilts labels so long names do not overlap. * **Prefix** — text before each axis value (for example, a currency symbol). * **Dynamic unit** — appends a measurement suffix from another data field. * **Suffix** — text after each axis value. **Min-Max Range** `Field` Locks the axis to fixed bounds instead of auto-scaling. Has no effect if Y-Axis Limits are set in the Setup tab. See [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters). **Number Format** `Field` Cleans up displayed numbers with decimals, percentage, thousands separator, and unit options. **Grid Lines** `Toggle` Shows or hides grid lines behind the chart. Set `Line width` in pixels and choose a grid line `Color`. **Multiple X-Axis** `Toggle` Allows more than one X-axis on supported charts. **Bar Height** `Field` Sets bar thickness on horizontal bar charts. ## Dynamic units Resolve prefix and suffix values from data at runtime instead of fixed text. Dynamic units are available wherever static prefix or suffix formatting exists, including axis values, data labels, and chart tooltips. For each prefix or suffix field, choose: | Option | Behavior | | - | - | | **Static value** | Fixed text you enter (for example, degrees F or kW) | | **Dynamic value** | Select a **Unit Name** from the dropdown to resolve the unit from a data column at runtime | Select `New Dynamic Unit` to create a rule that maps a metric or column to a unit suffix. Existing rules list the metric name and unit type. Use the three-dot menu on any rule to edit or delete it. Conditions can use an aggregate function. For example, add a temperature unit suffix to readings from temperature points. > [!NOTE] > > Dynamic units help when you deploy the same dashboard across buildings that use different measurement units. The widget adapts at runtime without manual restyling per site. > [!NOTE] > > Widget `Dynamic units` format chart labels at display time. The [platform unit conversion foundation](/products/building-bi/data-sources#point-bounds-and-unit-conversion) normalizes values in metrics and bounds logic. It does not change raw stored readings or trend display units yet. ## Bar configuration Available on Bar and Combo charts (including horizontal and stacked variants). Adjusts bar thickness and spacing between bars. Sets how multiple series are arranged: `Grouped` (side by side) or `Stacked` (on top of one another). ## Data labels Value labels printed directly on chart elements. On Combo charts, bar and line labels are configured separately. **Show labels** `Toggle` Shows or hides the labels. **Shows** `Field` What each label displays: Value, Name, Name + Value, Percentage, and related options. **Placement** `Field` Places the label `Inside` or `Outside` the chart element. **Rotation and Interval** `Field` Sets label angle in degrees and how many labels to skip. **Font** `Field` Sets font family, size, weight (bold), and style (italic) for data label text. **Prefix** `Field` Adds text before each data label value. **Dynamic unit** `Field` Appends a measurement suffix based on another data field. Select a unit from the dropdown. **Suffix** `Field` Adds text after each data label value. **Format** `Toggle` Controls numeric display. Set `Units` to a format type, configure `Decimals`, and enable `Thousands` separators for large values. **Label Line** `Toggle` On Pie charts, shows the leader line connecting a slice to its outside label. ## Legends Identifies series in multi-series charts. **Show legend** `Toggle` Shows or hides the legend. **Position** `Field` Moves the legend to the top, bottom, left, or right using position icons. Set X and Y offset values in pixels for fine placement. **Long legends** `Field` When there are too many series to fit, the legend scrolls rather than wrapping. **Font** `Field` Sets font family, size, weight, style, and color for legend entries. ## Chart tooltips The pane that appears when a viewer hovers or clicks a data point. Use tooltips for exact values, timestamps, or device names without cluttering the chart. ![Chart Configuration Style tab with Chart Tooltips section expanded showing Type toggle between Item and Axis, Order set to Series, Background color, Font set to Roboto 12px, Prefix, Dynamic unit dropdown, Suffix, Dynamic unit, Units set to None, Decimals set to 2, and Thousands toggle enabled](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-style-chart-tooltips.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=fafc60c7f2d49f66712208f5e2f083b2) Chart Tooltips style section showing Type, Order, Background, Font, Prefix, Dynamic unit, Suffix, Units, Decimals, and Thousands settings **Show tooltip** `Toggle` Shows or hides the tooltip. **Trigger** `Field` Choose `Hover` or `Click`. On cross-filter charts, Click is used for filtering, so Hover keeps both behaviors available. **Type** `Field` Choose `Item` (hovered point only) or `Axis` (all series at that axis position). **Order** `Field` Sets how tooltip entries are sorted. Choose `Series` to match the legend, or sort by value ascending or descending. **Background** `Field` Sets the tooltip background color. **Font** `Field` Sets font family, size, weight, style, and color for tooltip text. **Prefix and Suffix** `Field` Adds text before or after tooltip values. **Dynamic unit** `Field` Appends a measurement suffix based on another data field. **Units, Decimals, and Thousands** `Field` Controls numeric formatting in tooltips. Set `Units`, configure `Decimals`, and toggle `Thousands` separators. ## Colors Sets the color of data series in the `Style` tab. Managed palettes live in Settings. See [Color tools](/products/building-bi/reference/color-tools) for full detail. | Mode | Effect | | - | - | | Color Scheme | Apply a named palette across the series. | | Single Color | One color for the whole chart. | | Gradient | Shade values from a low color through to a high color (optionally with a midpoint). | | Value Ranges | Assign colors to value bands (for example, green below 70, red above). | | Per-Series | Override the color of an individual series. | | Conditional | Color cells or points by a rule. | Number and Gauge widgets can also color the value by whether it is under, equal to, or over its target. ## Line styles and markers For Line and Combo charts. `Line Styles` sets line thickness and dash style. Choose `Default Line Style` for uniform lines, or expand `Custom Line Styles` to configure each series. Select the edit icon next to a series to customize it. `Markers` adds dots or symbols at each data point. Set `Type` (Circle, Square, Triangle, Diamond), `Size` in pixels, and toggle `Show all markers` to display markers at every point or only at key intervals. ## Confidence bands For Line charts. A confidence band is a shaded range drawn around a series to show uncertainty (for example, a 95% interval). Each band is configured with: | Field | Effect | | - | - | | Confidence band of | The existing series the band attaches to. | | Name | A label for the band, shown in the legend. Must be unique on the widget. | | Lower and Upper Boundary | The fields (with an aggregate function) that set the bottom and top of the band. Each must return a number. | | Show on legend | Whether the band appears in the legend. | | Color | The band's fill color. | You can add several bands, including more than one on the same series. Two bands cannot use the same series and the same boundary fields. ## Mark areas Shaded background zones that highlight a range — a peak window, an acceptable operating band, or a fault threshold. Each area is set with the axis to draw on (X or Y), a lower and upper boundary, a color, and an optional name (with its own position and font). Mark areas can use dynamic column values or static boundaries. Additional options control fill color, opacity, and label placement. Add as many as needed. Available on Bar, Line, Combo, Scatter, and Boxplot charts. ## Reference lines Static horizontal or vertical lines for marking a setpoint or threshold. Reference lines can use dynamic column values or fixed positions. Style options include line color, thickness, and label formatting. Add one or more per chart. Available on Bar, Line, Combo, Scatter, and Boxplot charts. ## Data bars For tables. In-cell horizontal bars that show each numeric value's magnitude. On a Pivot table, bars appear only on the lowest level of the hierarchy, not on sub-totals or totals. | Option | Choices or values | Effect | | - | - | - | | Apply to | One column or several columns | Which numeric columns get bars. | | Display | Bar only or Bar and value | Whether the number stays visible alongside the bar. | | Scale | Static or Dynamic | Fixed min and max, or bounds taken from the column's own range. | | Positive or Negative color | Two colors | Separate colors for positive and negative bars. | ## Zoom and scroll For long time-series or large datasets. `Zoom` lets the viewer focus on part of the range. Enable it per axis. Viewers can click and drag to zoom into a region. Scroll-wheel zoom is supported on some chart types. Available on line, combo, and time-series chart types. `Scroll` keeps the chart compact by showing a set number of items at a time with a scroll bar, per axis. ![Chart Configuration Style tab with Scroll section expanded showing X-Axis Items set to 5 and Y-Axis Items set to 5](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-style-scroll.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=163a1052e9eea33c07a734397f6c096d) Scroll style section showing X-Axis and Y-Axis Items fields **X-Axis Items** `Field` Sets how many data points are visible on the X-Axis at once. Remaining points are accessible by scrolling. For example, `5` shows five items at a time. **Y-Axis Items** `Field` Sets how many data points are visible on the Y-Axis at once. Works the same as X-Axis Items for vertically oriented data. ## Margins External spacing around the plot area as a percentage of the widget size. Configure `Top`, `Right`, `Bottom`, and `Left` independently with the slider or by entering a percentage. Use margins to center the chart or stop axis labels from being clipped. ![Chart Configuration Style tab with Margins section expanded showing Top set to 15%, Right set to 5%, Bottom set to 10%, and Left set to 15% with slider controls](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-style-margins.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c13bae5474ea83a0f0fb38bc563de449) Margins style section showing Top, Right, Bottom, and Left percentage sliders ## Style options by chart type Which Style sections appear depends on the chart type. `General`, `Colors`, and `Margins` are nearly universal. The table below lists the sections specific to each type. | Chart type | Style sections it adds | | - | - | | [Bar](/products/building-bi/reference/chart-types#bar) (all variants) | X and Y Axis, Data Labels, Legends, Bar Configuration, Mark Areas, Reference Lines, Zoom and Scroll | | [Line](/products/building-bi/reference/chart-types#line) (all variants) | X and Y Axis, Secondary Y-Axis, Data Labels, Legends, Line Styles and Markers, Confidence Bands, Mark Areas, Reference Lines, Zoom and Scroll | | [Combo](/products/building-bi/reference/chart-types#combo) | X and Y Axis, Secondary Y-Axis, Bar Configuration, Line Styles and Markers (bar and line styled separately), Data Labels, Legends, Mark Areas, Reference Lines, Zoom and Scroll | | [Scatter](/products/building-bi/reference/chart-types#scatter) | X and Y Axis, Markers, Regression Line, Legends, Mark Areas, Zoom | | [Advanced Scatter](/products/building-bi/reference/chart-types#advanced-scatter) | X and Y Axis, Data Labels, Markers, Legends | | [Pie](/products/building-bi/reference/chart-types#pie) | Data Labels (with label line), Legends, Donut | | [Sunburst](/products/building-bi/reference/chart-types#sunburst) | Borders, Minimum Angle, Radius, Legends | | [Treemap](/products/building-bi/reference/chart-types#treemap) | Borders, Drill-down, Data Labels, Legends | | [Polar Bar](/products/building-bi/reference/chart-types#polar-bar) (both) | Dimension Axis, Metric Axis, Polar Properties (center size, Radial or Polar), Data Labels, Legends, Zoom | | [Boxplot](/products/building-bi/reference/chart-types#boxplot) (both) | X and Y Axis, Mark Areas, Reference Lines, Zoom and Scroll | | [Tree](/products/building-bi/reference/chart-types#tree) | Orientation and Layout, X and Y Axis, Data Labels, Legends, Zoom and Scroll | | [Sankey](/products/building-bi/reference/chart-types#sankey) | Levels (per-band node and link colors), Data Labels, Legends, Zoom and Scroll | | [Gauge](/products/building-bi/reference/chart-types#gauge) | Value, Target, Scale (min-max), Data Labels | | [Card](/products/building-bi/reference/chart-types#card) and [Number](/products/building-bi/reference/chart-types#number-period) | Value, Description (Number with Target adds a Target value; Number with Period adds a Change indicator) | | [Multi-row Card](/products/building-bi/reference/chart-types#multi-row-card) | Card layout, Labels | | [Table](/products/building-bi/reference/chart-types#table-raw) (Raw, Aggregated, or Pivot) | Table Appearance, Data Bars | | [Building Date Time](/products/building-bi/reference/chart-types#building-date-time) | Date, Time, Timezone | | [Weather](/products/building-bi/reference/chart-types#weather) | Weather details (current, daily forecast, hourly) | | [Text](/products/building-bi/reference/chart-types#text) | Rich-text editing on the widget itself | | [Slicer](/products/building-bi/reference/chart-types#slicer) | Display options — see [Slicer widget](/products/building-bi/reference/slicer-widget) | ## Chart-type-specific sections Options that appear only on the chart types named. | Section | Chart type | Effect | | - | - | - | | Donut | [Pie](/products/building-bi/reference/chart-types#pie) | Turns the pie into a donut; sets the inner and outer radius and the ring border. | | Borders | [Pie](/products/building-bi/reference/chart-types#pie), [Sunburst](/products/building-bi/reference/chart-types#sunburst), [Treemap](/products/building-bi/reference/chart-types#treemap) | Border color, width, and corner radius around each slice or rectangle. | | Minimum Angle | [Sunburst](/products/building-bi/reference/chart-types#sunburst) | The smallest slice angle, so thin slices stay visible. | | Radius | [Sunburst](/products/building-bi/reference/chart-types#sunburst) | The size of the rings. | | Drill-down | [Treemap](/products/building-bi/reference/chart-types#treemap) | Controls the click-to-expand behavior. | | Polar Properties | [Polar Bar](/products/building-bi/reference/chart-types#polar-bar) | The center hole size and whether bars are drawn `Radial` or `Polar`. | | Dimension and Metric Axis | [Polar Bar](/products/building-bi/reference/chart-types#polar-bar) | The polar equivalents of the X and Y axes (title, labels, format, range). | | Regression Line | [Scatter](/products/building-bi/reference/chart-types#scatter) | Adds a trend line (linear), with its own line style, weight, color, name, and an option to show it in the legend. | | Value | [Card](/products/building-bi/reference/chart-types#card), [Number](/products/building-bi/reference/chart-types#number-period), [Gauge](/products/building-bi/reference/chart-types#gauge), [Advanced Scatter](/products/building-bi/reference/chart-types#advanced-scatter) | The displayed number: font, color, number format, and a prefix or suffix such as kWh. | | Target | [Gauge](/products/building-bi/reference/chart-types#gauge), [Number with Target](/products/building-bi/reference/chart-types#number-target) | The target value's label and formatting; Gauge also sets the scale's minimum, maximum, and target. | | Change indicator | [Number with Period](/products/building-bi/reference/chart-types#number-period) | The period-over-period change, shown as a percentage with an up/down arrow and separate colors for positive and negative. | | Description | [Card](/products/building-bi/reference/chart-types#card), [Number](/products/building-bi/reference/chart-types#number-period) | A caption beneath the value. | | Card layout and Labels | [Multi-row Card](/products/building-bi/reference/chart-types#multi-row-card) | Card orientation, spacing, borders, and label formatting. | | Table Appearance | [Tables](/products/building-bi/reference/chart-types#table-raw) | Header, row, sub-total, and total formatting (font, color, height, word wrap); pagination; borders; and per-column formatting (number or date format, background and font colors, hyperlinks). | | Levels | [Sankey](/products/building-bi/reference/chart-types#sankey) | Per-band node and link colors, and band labels. | | Orientation and Layout | [Tree](/products/building-bi/reference/chart-types#tree) | The branch direction and whether the tree is drawn as an orthogonal or radial layout. | | Date, Time, and Timezone | [Building Date Time](/products/building-bi/reference/chart-types#building-date-time) | Date format and length, 12- or 24-hour time and precision, the timezone label, and alignment. | | Weather details | [Weather](/products/building-bi/reference/chart-types#weather) | Whether to show current conditions, building name/address, a daily forecast (and how many days), and the hourly chart, plus its colors. | ### Combo chart sections Combo charts combine bar and line series and expose the most style sections of any chart type: * **Secondary Y-Axis** — configures the right-side axis used by line series. Same options as Y-Axis (title, values, grid lines). * **Bar Configuration** — controls bar thickness and spacing between bars. * **Bar Data Labels** — value labels on bar elements. Same options as Data Labels, scoped to bars only. * **Line Data Labels** — value labels on line elements. Same options as Data Labels, scoped to lines only. * **Bar Colors** — colors for bar series. Uses the `Type` dropdown (Color Scheme, Color Palette, Color Series, Range, Gradient). * **Line Styles** — line appearance. Choose `Default Line Style` or expand `Custom Line Styles` per series. * **Line Colors** — colors for line series using the `Type` dropdown. When set to `Color Series`, each line series shows its assigned color and label. * **Markers** — data point markers on line series. Set `Type`, `Size`, and `Show all markers`. ### Weather widget sections The weather widget has a `General` section and a `Weather` section: * **Compact View** — toggles a condensed layout. * **Current Weather** — toggle `Show Building Name`, `Show Building Address`, and `Current Weather Details`. * **Daily Forecast** — show or hide the multi-day forecast. Set `Forecasted Days` (2 through 7) with the slider. * **Hourly Chart** — show or hide the hourly temperature chart. Set `Chart Fill Color` and `Chart Line Color`. * **Colors** — set `Labels Color` and `Values Color` for weather text. ### Table widget sections Table widgets (Table Raw, Table Aggregated, Table Pivot) use a different Style tab structure: * **General** — includes `Dynamic Column Width`, `Disable Tooltips`, and `Show Row Info in Tooltip` in addition to standard general settings. * **Batch Apply Actions** — apply style changes across all columns at once. * **Order Columns** — reorder columns by dragging. * **Table Properties** — overall table behavior and layout. * **Data Bars** — inline bar visualizations within table cells. * **Headers** — header row styling. Set `Height`, `Word wrap`, `Font`, `Alignment`, and `Background`. * **Rows** — data row styling. Set `Height`, `Word wrap`, `Font`, and `Alignment` independently from headers. * **Total** — totals row at the bottom. Set `Label`, `Height`, `Word wrap`, `Font`, and `Background`. * **Pagination** — page navigation for large datasets. Set `Custom colors` for label, page size, and total label colors. * **Borders** — set `Borders type`, `Width`, and border `Color`. #### Column-level styling Each column appears in the left panel. Select a column to open its style panel: **Column** `Field` Sets column `Width` in pixels. A value of `0` uses auto-width. **Borders** `Field` Sets `Borders type`, `Width`, and border `Color` for that column. **Header** `Field` Overrides header style for this column. Set `Alignment`, `Font`, and `Background` color. **Rows** `Field` Overrides row style for this column. Set `Alignment` and `Font` independently from the header. **Prefix** `Field` Adds text before each cell value. **Dynamic unit** `Field` Selects a unit from the `Choose Unit` dropdown to apply unit conversion to the prefix. **Suffix** `Field` Adds text after each cell value (for example, degrees C). **Empty Value** `Field` Sets the display text for cells with no data (for example, a dash). **Number format** `Field` Configures numeric display. Set `Units` (Adaptive, None, or a specific unit), `Decimals`, and toggle `Thousands`. **Font Color** `Field` Sets `Type` to `Static` for a fixed color or `Dynamic` for conditional coloring. Select the `Color` when using Static. **Background Color** `Field` Sets `Type` to `Static` or `Dynamic`. Use Dynamic for conditional background colors based on value ranges. **Total** `Field` Configures this column in the totals row. Set `Aggregate Function` (Sum, Average, Min, Max, Count). Configure `Font Color` and `Background Color` with Static or Dynamic types. **URLs** `Field` Applies a URL from `Apply URL` to make cell values clickable links. URLs must be configured in the data source. **Actions** `Field` Applies an action from `Apply Actions` to enable interactive behaviors on cell click. ## Bulk and reusable styling Default styles, bulk styling, and copy/paste apply appearance across many widgets without redoing each option. These workflows live in [Widget customization](/products/building-bi/widget-customization#default-styles). * **Default styles** — save a page-level look and apply it on demand. Changing the default does not alter existing widgets until you re-apply it. See [Default styles vs global styles](/products/building-bi/widget-customization#default-styles). * **Copy and Paste Style** — replicate the appearance of one widget onto others, including `Paste Styles on Selected`. * **Bulk selection** — select widgets of a single type to edit general and chart-specific options. A mixed selection limits you to general options. See [Keyboard shortcuts and bulk selection](/products/building-bi/reference/keyboard-shortcuts). ## See also * The data side of a chart: [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters) * Color options in depth: [Color tools](/products/building-bi/reference/color-tools) * Available chart types: [Chart types](/products/building-bi/reference/chart-types) * The principles behind good styling: [Dashboard styling principles](/products/building-bi/widget-customization#styling-best-practices) * Task guide: [Widget customization](/products/building-bi/widget-customization) ## Next steps > [card] [Widget customization](/products/building-bi/widget-customization) > > Apply default styles, bulk styling, and copy/paste workflows. > [card] [Color tools](/products/building-bi/reference/color-tools) > > Configure series colors, gradients, ranges, and palettes. ## Related reading > [card] [Widget customization](/products/building-bi/widget-customization) > > Style widgets, apply defaults, manage palettes, and add graphics. > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Match chart types to the question you need to answer. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup requirements for every widget type. > [card] [Color tools](/products/building-bi/reference/color-tools) > > Configure series colors, gradients, and palettes. # Chart types Source: https://docs.kodelabs.com/products/building-bi/reference/chart-types Lookup Setup requirements for every Building BI widget and chart type available from the Chart List. Use [Dashboards](/products/building-bi/dashboards#add-widgets-and-charts) to add a chart to a dashboard. The widget/chart types available from the **Chart List** in dashboard edit mode are listed here. Each type has its own Setup requirements (see [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters)) and a Style panel that varies by type (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). Add a chart by dragging it onto the canvas or double-clicking it in the Chart List. For choosing a suitable visual, see [Choosing the Right Visualization](/products/building-bi/concepts/choosing-visualizations). ## Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Vertical bars comparing values between categories. ![Bar chart example in Building BI](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-chart-types-bar.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9e97806b5ce5227dbb2d01ffd94683a7) Bar chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple X-Axis dimensions that by default create additional subdivisions of the X-Axis. The Drill Down & Expand All toggles interact with additional X-Axis. | Yes | | Drill Down | If you have multiple X-Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the Y-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | No | | Expand All | If you have multiple X-Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | No | | Legend (Breakdown Categories) | Splits/categorizes information into adjacent bars per X-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | No | | Y-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Horizontal Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Horizontal bars comparing values between categories. ![Horizontal Bar chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-horizontal-bar.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=37a7a93d43c7804c84a467a63ef713d7) Horizontal Bar chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple Y-Axis dimensions that by default create additional subdivisions of the Y-Axis. The Drill Down & Expand All toggles interact with additional Y-Axis. | Yes | | Drill Down | If you have multiple Y-Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the X-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | No | | Expand All | If you have multiple Y-Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | No | | Legend (Breakdown Categories) | Splits/categorizes information into adjacent bars per Y-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | No | | X-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Stacked Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Vertical bars comparing values between categories. Legend categories stack values rather than creating new bars. ![Stacked Bar chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-stacked-bar.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=f3036b60520481ba766e78eddc7f6d23) Stacked Bar chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple X-Axis dimensions that by default create additional subdivisions of the X-Axis. The Drill Down & Expand All toggles interact with additional X-Axis. | Yes | | Drill Down | If you have multiple X-Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the Y-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | No | | Expand All | If you have multiple X-Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | No | | Legend (Breakdown Categories) | Splits/categorizes information into *stacked bars* per X-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | No | | Y-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Horizontal Stacked Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Horizontal bars comparing values between categories. Legend categories stack values rather than creating new bars. ![Horizontal Stacked Bar chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-horizontal-stacked-bar.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=692ba72407c3eb8ef87574a269c2cf2e) Horizontal Stacked Bar chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple Y-Axis dimensions that by default create additional subdivisions of the Y-Axis. The Drill Down & Expand All toggles interact with additional Y-Axis. | Yes | | Drill Down | If you have multiple Y-Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the X-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | No | | Expand All | If you have multiple Y-Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | No | | Legend (Breakdown Categories) | Splits/categorizes information into *stacked bars* per Y-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | No | | X-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Combo Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Line(s) and Bar(s) over a shared axis. Bar(s) uses Primary Y-Axis and Line(s) Secondary Y-Axis ![Combo chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-combo.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=6a8e5d6a752e3a4cb99c9fc7127b4712) Combo chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. The Y-Axis creates the bar. You can add multiple X-Axis dimensions that by default create additional subdivisions of the X-Axis. The Drill Down & Expand All toggles interact with additional X-Axis. | Yes — Either a Y-Axis and/or a Secondary Y-Axis is required. | | Secondary Y-Axis | Additional Y-Axis for line values. Axis appears on right-hand side of chart. | Yes — Either a Y-Axis and/or a Secondary Y-Axis is required. | | Drill Down | If you have multiple Y-Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the X-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | No | | Expand All | If you have multiple Y-Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | No | | Legend (Breakdown Categories) | Splits/categorizes information into *adjacent bars* per Y-Axis dimension by default. (Ex, total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to make bars stack, adjust spacing, and colors. | No | | X-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No — BigQuery metric require a DateTime filter | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Line Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Line(s) over a continuous axis. Multiple lines will overlay on Y-Axis. ![Line chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-line.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=f2fc355a77fdce816f4e0a5c7e19df26) Line chart | Parameter | Description | | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple X-Axis dimensions and Y-Axis that by default create additional subdivisions. The Drill Down & Expand All toggles interact with the additional axes. | | Drill Down | Toggle. If you have multiple axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the other dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | | Expand All | Toggle. If you have multiple axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | | Legend | Splits/categorizes information into multiple Lines per X-Axis dimension. (e.g. total energy usage broken down by floor). | | Y-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Line Area Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Line(s) over a continuous axis. Multiple lines will overlay on Y-Axis with the area under the line being shaded. ![Line Area chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-line-area.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=da01c8cfc157d764e1ebdbc5d16cabd0) Line Area chart | Parameter | Description | | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple X-Axis dimensions and Y-Axis that by default create additional subdivisions. The Drill Down & Expand All toggles interact with the additional axes. | | Drill Down | Toggle. If you have multiple axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the other dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | | Expand All | Toggle. If you have multiple axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | | Legend | Splits/categorizes information into multiple Lines per X-Axis dimension. (e.g. total energy usage broken down by floor). | | Y-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Stacked Line Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Line(s) over a continuous axis. Multiple lines will *sum* on Y-Axis. ![Stacked Line chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-stacked-line.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=65ce961b25cc3790a68c2cf11c89097d) Stacked Line chart | Parameter | Description | | - | - | | X-Axis & Y-Axis | The primary dimensions for the data. You can add multiple X-Axis dimensions and Y-Axis that by default create additional subdivisions. The Drill Down & Expand All toggles interact with the additional axes. | | Drill Down | Toggle. If you have multiple axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the other dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | | Expand All | Toggle. If you have multiple axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | | Legend | Splits/categorizes information into multiple Lines per X-Axis dimension. (e.g. total energy usage broken down by floor). | | Y-Axis Limits | Dynamically adjusts min/max boundaries to change the visual scale of the bars. **Overrides the Style-tab Min/Max Range** (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)). | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Pie Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Proportional Categorical slices of total value ![Pie chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-pie.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=d3772a007e63d5c7b1f62f0818ee535e) Pie chart | Parameter | Description | | - | - | | Legend | The primary dimensions for the data. Splits the *Value* in slices of the sum *Value*. Multiple columns can be added to the legend to create a hierarchy that by default create subdivisions. The Drill Down & Expand All toggles interact with additional hierarchies. | | Drill Down | If you have multiple legends Drill Down separates different dimensions into a hierarchy that shows one dimension at a time. Ex. Count of occupied VAV per area vs unoccupied, enabling drill down you can drill down into one area to see all of the device names and their occupied status. | | Expand All | If you have multiple dimensions Expand All merges the dimensions into many subdivisions. Ex. Count of occupied vs unoccupied VAVs per Building & Floor. | | Value | The metric total that is subdivided by the legend. Must be numeric. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Sunburst Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Nested proportional Categorical slices of total value ![Sunburst chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-sunburst.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=54d97050b098a1c0e5084dec6b3a292f) Sunburst chart | Parameter | Description | | - | - | | Legend | The primary dimensions for the data. Splits the *Value* in slices of the sum *Value*. Multiple columns can be added to the legend to create a hierarchy whose rings are nested within one another. | | Value | The metric total that is subdivided by the legend. Must be numeric. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Multi-row Card A compact display of many value(s) or label(s) across a dimension. Similar to a Table. ![Multi-row Card chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-multi-row-card.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=6a52f136999a266a499d0fb29c3af271) Multi-row Card chart | Parameter | Description | | - | - | | Category | The primary dimensions for the data. Splits the *Value* in sections for each degree of the dimension. You can have multiple category columns. | | Value | The metric total that is split across each category | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Card A compact display of one value or label. ![Card chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-card.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=785e943109b1b3455b75b8a95af85a1f) Card chart | Parameter | Description | | - | - | | Value | The data displayed in the card | | Filters | Restricts the data shown. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Number (Period) A compact display of one metric value compared to the same metric value from a previous time period. ![Number (Period) chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-number-period.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=1dd7443e46a0c400594de1247a443f69) Number (Period) chart | Parameter | Description | | - | - | | Value | The metric displayed in the card | | Date Filter | Must be Date or DateTime type. Sets the metric time period that is the basis of comparison. | | Comparison Method | Dropdown for scale of time periods in comparison. Options: Day over Day, Week over Week, Month over Month, Year over Year. | | Filters | Restricts the *Value* shown. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Number (Target) A compact display of one metric value being compared to a target metric value. Values are concatenated with a '/'. ![Number (Target) chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-number-target.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=6a68807212dd807ed5d1e1fc1ca5a095) Number (Target) chart | Parameter | Description | | - | - | | Value | The metric displayed in the card | | Filters | Restricts the Value shown. See [Filter Options](/products/building-bi/reference/filter-options). | | Target Value | The metric displayed in the card that is the target for the *Value* | | Target Filters | Restricts the Target *Value* shown. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Number with Trend-line A compact display of one metric value with a miniature visualization of that metric value trend across a time period. ![Number with Trend-line chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-number-with-trend-line.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=bdab9b5a97b7bd7f2be2ba1d61af8a82) Number with Trend-line chart | Parameter | Description | | - | - | | Value | The metric displayed in the card | | Trend Axis | Must be Date or DateTime type. Displays value over that time period. | | Filters | Restricts the Value shown. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Heatmap Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). A grid that encodes a value as cell color across two axes (X and Y) — the color is the "third axis." ![Heatmap chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-heatmap.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=068dd11b59f25da626d00812248a1098) Heatmap chart | Parameter | Description | | - | - | | X-Axis & Y-Axis Dimension | The primary dimensions for the data. Creates a matrix across both axes, one cell per combination. You can use multiple columns for both the X-Axis and Y-Axis dimensions. | | Value | The metric displayed for each dimension represented by color. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) and [Color Tools](/products/building-bi/reference/color-tools). | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Treemap Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Nested rectangles sized by value; click an area to break it into smaller divisions. ![Treemap chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-treemap.gif?s=c23c4f0b9048dd18c87b10868160adea) Treemap chart | Parameter | Description | | - | - | | Hierarchy | The primary dimensions for the data. Creates the categorization that splits the area. Multiple *Hierarchy* values are required to allow for the drill-down properties of the TreeMap. Edit the properties of the drill-down see the style tab (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)) | | Value | The metric displayed for each dimension represented by area. | | Additional Value | Additional metrics that are displayed on a chart tooltip or data labels. Many metrics can be added. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Scatter Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Data points plotted against two **metric** axes — used to reveal correlation or clustering between two measures. ![Scatter chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-scatter.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=2f2febded377ea911896ea69b57b4f7c) Scatter chart | Parameter | Description | Required? | | - | - | - | | X-Axis & Y-Axis | The two metrics that position each point (e.g. a generator run's peak temperature vs. its runtime). | Yes | | Category | The group being plotted (e.g. "generator runs"). Each row in the category becomes a point. | Yes | | Legend | Splits the points into colored series (e.g. set the Legend to Device Name to separate each device's runs). | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | > [!NOTE] > > Scatter vs Advanced Scatter Standard Scatter plots two **metrics**. [Advanced Scatter](#advanced-scatter) plots two **dimensions** and sizes each symbol by a metric. ## Advanced Scatter Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Array of data points whose axes are **dimensions** (not metrics, which is what distinguishes it from the standard [Scatter](#scatter)), with each symbol sized by a metric value. Useful for visualizing distribution across categorical breakdowns. ![Advanced Scatter chart example in Building BI](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-chart-types-advanced-scatter.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=e452b44750a217aa6d96291cf45a1cd8) Advanced Scatter chart | Parameter | Description | Required? | | - | - | - | | X-Axis | One or more **dimension** columns plotted on the X-Axis. Supports Single or Multiple X-Axis (set by the *Single Axis / Multiple Axis* toggle). | Yes | | Y-Axis | One or more **dimension** columns plotted on the Y-Axis. | Yes | | Metric | A single metric column whose values drive both the symbol rendering and symbol size. | Yes | | Tooltips | One or more metric columns (with aggregate function) shown in the tooltip. | No | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. Filters set in chart configuration are always applied and cannot be unselected from the dashboard view. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Sort by the key column or by tooltip columns. See [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters). | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Boxplot Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Visualizes the distribution (median, quartiles, and outliers) of numerical values on the Y-Axis across categorical X-Axis values. ![Boxplot chart example in Building BI](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-chart-types-boxplot.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=e8d5f70da1cb9aa35288d3ff2fa154c7) Boxplot chart | Parameter | Description | | - | - | | Y-Axis | The numerical axis of what values you are trying to show the distribution of values. Ex. The distribution of FCU Air Temperature per floor. The Air Temperature would be the *Y-Axis*. | | Distributed Across | The category whose values build the distribution graphic. Ex. The distribution of FCU Air Temperature per floor. The FCUs (likely their device names) would be the *Distributed Across*. | | X-Axis | The categorical axis of what groups you are trying to show the distribution of values. Ex. The distribution of FCU Air Temperature per floor. The floor would be the *X-Axis*. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Horizontal Boxplot Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Horizontally visualizes the distribution of numerical values on a X-Axis along some categorical Y-Axis Values. ![Horizontal Boxplot chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-horizontal-boxplot.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=08be739e75b531ca39d98fd7dc4a6afa) Horizontal Boxplot chart | Parameter | Description | | - | - | | Y-Axis | The categorical axis of what groups you are trying to show the distribution of values. Ex. The distribution of FCU Air Temperature per floor. The floor would be the *Y-Axis*. | | Distributed Across | The category whose values build the distribution graphic. Ex. The distribution of FCU Air Temperature per floor. The FCUs (likely their device names) would be the *Distributed Across*. | | X-Axis | The numerical axis of what values you are trying to show the distribution of values. Ex. The distribution of FCU Air Temperature per floor. The Air Temperature would be the *X-Axis*. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Gauge A compact display of one metric value being compared to a target metric value. The proportion between the value and target value is visualized by a curved progress bar. ![Gauge chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-gauge.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=e49c783137dca12494b5df2f555d2706) Gauge chart | Parameter | Description | | - | - | | Value | The metric displayed in the card | | Target Value | The metric that is the limit of the gauge that is affected by the same *Filters* as *Value*. This parameter overrides any hardcoded min/max axis in the style settings (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)) | | Filters | Restricts the data of the *Value* and *Target Value*. See [Filter Options](/products/building-bi/reference/filter-options). | | Scale Upper/ Lower Limit | Metric values that are the minimum/maximum values of the gauge that is affected by its own *Scale Filters*, a detached filter from the *Value*. This parameter overrides any hardcoded min/max axis in the style settings (see [Chart Styling Options](/products/building-bi/reference/chart-styling-options)) | | Scale Filter | Restricts the data of *Scale Upper/ Lower Limit*. See [Filter Options](/products/building-bi/reference/filter-options). | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Table Raw Rows and columns of raw values from the selected Building BI `Data Source`. See [Table types](/products/building-bi/concepts/choosing-visualizations#table-types). ![Table Raw chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-table-raw.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=a1add0ae24b73578b95cb52ad5d52952) Table Raw chart | Parameter | Description | | - | - | | Columns | Column values from the selected `Data Source` to show in the table | | Filters | Restricts the data of the *Columns*. See [Filter Options](/products/building-bi/reference/filter-options). | | Rows per Page | Dropdown, select how many rows show prior to pagination. Options: 5, 10, 20 (default). 50. | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Table Pivot A cross-tab table: rows come from a hierarchy, columns are pivoted from a dimension's distinct values, and each cell holds an aggregated value. See [Table types](/products/building-bi/concepts/choosing-visualizations#table-types). ![Table Pivot chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-table-pivot.gif?s=aef5d407cc8d3359a3e8321219137c64) Table Pivot chart | Parameter | Description | | - | - | | Hierarchy | What rows you want the pivoted table to be mapped too. Adding multiple Hierarchy elements nests the columns into dropdowns by default. Ex. A table for run hours per device that drops down to shows the run hours per day. Device Name and Date would be the hierarchy columns. | | Pivoted Columns | The columns that *Values* aggregates data from then pivots to the Hierarchy. | | Values | Applies aggregation functions (count, sum, first, last, etc.) to the column values for each category of the *Pivoted Column*. Ex. If your *Hierarchy* is devices, *Pivoted Column* is Hours of Day, and your *Value* is sum of running minutes. You would get a table with a row for each device and columns for each hour of the day and each cell would have the sum of running minutes. | | Adjunct Metrics | Additional columns appended to the table. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Table Aggregated Columns and values aggregated to those points. See [Table types](/products/building-bi/concepts/choosing-visualizations#table-types). ![Table Aggregated chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-table-aggregated.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=80dfd18fd22f9288e889b29ddbd01729) Table Aggregated chart | Parameter | Description | | - | - | | Columns | Column values from the selected `Data Source` to show in the table | | Aggregated Columns | Metric values aggregated (sum, max, count, last, etc.) for each column value. | | Filters | Restricts the data of the *Columns*. See [Filter Options](/products/building-bi/reference/filter-options). | | Rows per Page | Dropdown, select how many rows show prior to pagination. Options: 5, 10, 20 (default). 50. | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Text A widget that holds stylized text — titles, notes, commentary, or section dividers. It has no Setup parameters; you type directly into the widget and style it from the side panel. The Text widget supports: Font Family, Font Size, Line Height, text/background Color, **Insert Picture** (images auto-fit the widget), Background styling (color or transparent), and Padding & Alignment. A **bubble menu** appears on text selection for quick inline formatting (font size/family, bold, italic, underline, alignment, bulleted/numbered lists). Insert options such as pictures are only in the side panel, not the bubble menu. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options). ![Text chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-text.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=e460bfaa2fdb289b34e2975735cfbfe3) Text chart ## IFrame Embeds an external web page (an iframe) by URL. | Parameter | Description | | - | - | | Source URL | What URL is being embedded. | ## Weather Shows the current and forecasted weather at a specific building. In portfolio view you must select a building. Editing this widget is done through styling options. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) ![Weather chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-weather.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=f432564e1977e9300d3fba69a3085ef1) Weather chart | Parameter | Description | | - | - | | Building | Building which the weather location is based on. | ## Sankey Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). A flow diagram where the width of each link is proportional to the quantity flowing between stages. ![Sankey chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-sankey.gif?s=b9ace99d40e85424794d44e266902b03) Sankey chart | Parameter | Description | Required? | | - | - | - | | Hierarchy | At least two columns are required. Each column becomes a stage (band) in the flow; the order sets the left-to-right sequence (e.g. Source → Sub-meter → Load). | Yes | | Value | The metric that sizes each flow, aggregated (sum, max, count, last, etc.) per link. | Yes | | Filters | Restricts the data shown. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Slicer An on-canvas, interactive filter control bound to a single column. Viewers change the selection to filter the widgets in its scope. The display adapts to the column's data type (dropdown/flat for strings and booleans, a min/max slider for numbers, and date-range pickers for dates). For the full configuration (data types, selection modes, display options) see [Slicer Widget](/products/building-bi/reference/slicer-widget); for how slicer filters interact with other filters see [Filter Options](/products/building-bi/reference/filter-options) and [Filter scopes](/products/building-bi/reference/filter-options#filter-scope-hierarchy). ![Slicer chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-slicer.gif?s=6387132fcc65f7964eba2ca0843b9306) Slicer chart ## Polar Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Radial or Polar bars comparing values between categories ![Polar Bar chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-polar-bar.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=aa1bd0ef07ce1b01d09920121c58f740) Polar Bar chart | Parameter | Description | | - | - | | Radial Axis | The primary dimensions for the data, categorical groups the bars are split into. You can add multiple Radial Axis dimensions that by default create additional subdivisions of the Radial Axis. The Drill Down & Expand All toggles interact with additional Radial Axis. | | Drill Down | If you have multiple Radial Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the Y-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | | Expand All | If you have multiple Radial Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | | Legend | Splits/categorizes information into adjacent bars per X-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | | Metrics (Value Axis) | Metric column(s) drawn as bars from the center outward; each metric adds a bar (≥1 required). Internal spec term *Metrics*. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Stacked Polar Bar Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Radial or Polar bars comparing values between categories. Legend categories stack values rather than creating new bars. ![Stacked Polar Bar chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-stacked-polar-bar.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=286011bb1d41ca84c7effb2ca19d7ed2) Stacked Polar Bar chart | Parameter | Description | | - | - | | Radial Axis | The primary dimensions for the data, categorical groups the bars are split into. You can add multiple Radial Axis dimensions that by default create additional subdivisions of the Radial Axis. The Drill Down & Expand All toggles interact with additional Radial Axis. | | Drill Down | If you have multiple Radial Axis dimensions Drill Down separates different dimensions into a hierarchy that are all compared against the Y-Axis dimension. Ex. AHU Run Hours per building, enabling drill down you can drill down into one building to see AHU Run Hours per floor. | | Expand All | If you have multiple Radial Axis dimensions Expand All merges the dimensions into many subdivisions. Ex. AHU Run Hours per Building & Floor. | | Legend | Splits/categorizes information into adjacent bars per X-Axis dimension. (e.g. total energy usage broken down by floor). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options) to adjust spacing and colors. | | Metrics (Value Axis) | Metric column(s) drawn as bars from the center outward; each metric adds a bar (≥1 required). Internal spec term *Metrics*. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Navigation A button widget that navigates the viewer to another page. Clicking anywhere inside the widget (except the title) triggers navigation. | Parameter | Description | Required? | | - | - | - | | Navigate to | Single-select dropdown of pages to navigate to. Supports a "no page selected" state (clicking does nothing). | Yes | Style options: button **Text** (defaults to the page name), **Font**, **Alignment**, and **Wrap text** (up to 3 rows). If the page name is longer than the button, it is truncated with `…` and shown in full on hover. The Navigation widget **cannot be exported or shared**. If its target page is removed, it reverts to the no-page-selected state. ## Time Series Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Visualizes how a value or state changes over time — when each change occurred and how long it held — drawn as colored spans, one row per category. Works best on raw Point Time Series (Real-Time) data. ![Time Series chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-time-series.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=6dbb2a638902f814ef9891ff3bf566ba) Time Series chart | Parameter | Description | | - | - | | Date Axis | Must be a DateTime value and works best in Point Time Series Real Time. This is the time axis the data is shown across. Most often you will use the column DateTimeLocal. To restrict this axis use *Date Filter*. | | Legend | The Y-Axis categories displayed across the *Date Axis*. Use *filters* to reduce down to a single device or point. | | Y-Axis | The metric shown on the values. Use *Filters* to reduce to a single point value to show accurate changes. | | Date Filter | The filter specifically for the *Date Axis* | | Tooltips | Additional metrics to include in the chart tooltip on the hover. | | Filters & Top N Filters | Restricts the data shown or keeps only the highest performers. See [Filter Options](/products/building-bi/reference/filter-options). | | Sort Order | Organizes the chart by a column's values and ranks order of impact. | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | ## Graphics Embeds a KODE Graphics layout (floor plan / device / system graphic) inside a dashboard, with the advantage that BI filters drive what the graphic shows. For example, a `device_name` page filter automatically focuses the graphic on that device. ![Graphics chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-graphics.gif?s=d252a1a3ee99e2940b393d0fe2b55a9e) Graphics chart | Parameter | Description | Required? | | - | - | - | | Graphic Type | Dropdown of graphic types: `AREA`, `DEVICE`, `SYSTEM`. Single select. | Yes | | Building | Dropdown of buildings that have graphics of the selected type. Single select. | Yes | | Entity | Dropdown of entities for the selected graphic type (e.g. for `DEVICE`, the list of devices that have graphics). Can also be filled from a BI page filter such as `device_name`; selecting an entity in the widget overrides the BI filter. | ✓ if not supplied by a BI filter | | Device Types | Dropdown of device types used in the layout's layers; used to filter out specific layers. Multiple select. | No | | Layout Name | For an Area graphic with multiple layouts, a dropdown to pick which layout to show. Not exposed as a configuration filter — only appears at render time when multiple layouts exist. | conditional | Graphic Type and Building form a required group: the other filters stay disabled until both are set. Once rendered, the graphic's markers and data points are filtered by all active dashboard, page, widget, slicer, drill-through, and cross filters (only `EQUALS` / `IN` string filters on mapped columns such as `device_name`, `device_id`, `point_name`, `point_id`, and ontology fields are applied). ## Timeline Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). A Gantt-style chart that draws each row as a horizontal bar spanning a start and end date — useful for visualizing when a state, task, or event was active and for how long. | Parameter | Description | Required? | | - | - | - | | Key | The column used to group data; rendered on the Y-Axis (one row per key). | Yes | | Start Date | The column that sets each bar's start point on the X-Axis. Must be a Date / DateTime column. | Yes | | End Date | The column that sets each bar's end point on the X-Axis. Must be a Date / DateTime column. | Yes | | Bar Label | A single column (no aggregate) shown as a label inside each bar. Cannot be used for sorting. | No | | Tooltips | One or more columns (no aggregate) shown in the tooltip. | No | | Filters | Restricts the data shown. Filters set in chart configuration are always applied and cannot be unselected from the dashboard view. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Sort by the Key column or by tooltip columns. Start Date, End Date, and Bar Label cannot be used for sorting. See [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters). | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Tree Supports [View as table](/products/building-bi/reference/accessibility/view-chart-as-table). Branching nodes for nested hierarchies. You can change the orientation and the layout (Radial vs Orthogonal) in the style tab. ![Tree chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-tree.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=c13af120d4131a5fed2db901f30b8e43) Tree chart | Parameter | Description | Required? | | - | - | - | | Hierarchy | The nodes on display. The column order sets the nesting order. E.g. a hierarchy of Area Name → Device Type yields a node per area, each leading to a node per device type in that area. | Yes | | Tooltips | One or more columns shown in the tooltip of each node. | No | | Filters | Restricts the data shown. Filters set in chart configuration are always applied and cannot be unselected from the dashboard view. See [Filter Options](/products/building-bi/reference/filter-options). | No | | Sort Order | Sort by hierarchy or tooltip columns. See [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters). | No | | Data Refresh Interval | How often the chart queries new data. Best practice: choose the **longest** acceptable interval to optimize load times. | Yes | ## Picture Show a picture from a file or external URL ## Camera Displays a live camera feed on the dashboard alongside charts and metrics. Add **Camera** from the Chart List in edit mode, choose a **Camera Type**, connect the feed, and resize or reposition it like any other widget. Offline and error states appear when the feed is unavailable. For add steps and behavior details, see [Camera widget](/products/building-bi/reference/camera-widget). | Parameter | Description | Required? | | - | - | - | | Camera Type | How the feed is connected: **iFrame**, **URI**, or **Device** | Yes | | Source URL | Stream or page URL to embed when **Camera Type** is **iFrame** | Yes when using iFrame | ## Building Date Time Shows the local building time. You can adjust the visuals in the Style tab. ![Building Date Time chart example in Building BI](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-chart-types-building-date-time.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=cac2f7c7a9a2bc87807ab0ab74ba492e) Building Date Time chart | Parameter | Description | | - | - | | Building | Building which the time is based on. | ## Feature support by type Not every interaction or style feature is available on every chart type. For the full list of Style sections by chart type, see [Chart Styling Options](/products/building-bi/reference/chart-styling-options). | Feature | Available on | | - | - | | View as table | Bar (all), Line (all), Combo, Pie, Sunburst, Treemap, Tree, Heatmap, Scatter, Advanced Scatter, Boxplot (all), Polar Bar (all), Time Series, Timeline, Sankey. See [View chart data as a table](/products/building-bi/reference/accessibility/view-chart-as-table). | | Drill-down / hierarchies | Tree-map (best), Bar, Line, Pie, Sunburst | | Cross-filtering (click a segment to filter the page) | Pie, Bar (chart segments generally) | | Drill-through (right-click a data point to open a filtered page/dashboard) | The same widgets that support cross-filtering; not metric-only charts. See [Drill-Through Filters](/products/building-bi/concepts/drill-through-filters). | | Navigate to KODE OS (right-click a data point or a linked column) | Tables (Raw, Aggregated, Pivot), Bar (all), Line (all, at a marker), Pie, Sunburst, Heat-map, Tree-map, Scatter, Boxplot, Sankey (nodes), Polar Bar (all), Time-series | | Zoom & Scroll | Line, Bar, Combo, Boxplot, Polar Bar, Tree, Sankey, Advanced Scatter, Heat-map, Scatter | | Bar Configuration (thickness/spacing) | Bar (all), Combo | | Line Styles & Markers | Line (all), Combo; markers also on Scatter and Advanced Scatter | | Mark Areas (shade an X- or Y-axis range) | Line, Bar, Combo, Scatter, Boxplot. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options). | | Reference Lines | Line, Bar, Combo, Scatter, Boxplot | | Confidence Bands (uncertainty band around a series) | Line charts only. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options). | | Regression Line (trend line) | Scatter only. See [Chart Styling Options](/products/building-bi/reference/chart-styling-options). | | Data Bars (in-cell bars) | Table Raw, Table Aggregated, Table Pivot (lowest level only). See [Chart Styling Options](/products/building-bi/reference/chart-styling-options). | | Donut mode | Pie | | Sort by another data-source column | See per-type support in [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters). | ## See also * Set up data for a chart: [Chart Setup Parameters](/products/building-bi/reference/chart-setup-parameters) * Style a chart: [Chart Styling Options](/products/building-bi/reference/chart-styling-options) · [Color Tools](/products/building-bi/reference/color-tools) * The interactive filter widget: [Slicer Widget](/products/building-bi/reference/slicer-widget) * Live camera feeds: [Camera widget](/products/building-bi/reference/camera-widget) * Drilling from a chart into a filtered view: [Drill-Through Filters](/products/building-bi/concepts/drill-through-filters) * The concept behind choosing a chart: [Choosing the Right Visualization](/products/building-bi/concepts/choosing-visualizations) * Accessible chart data: [View chart data as a table](/products/building-bi/reference/accessibility/view-chart-as-table) * Task guide: [Dashboards](/products/building-bi/dashboards) ## Next steps > [card] [Building BI overview](/products/building-bi/overview) > > Browse concept guides and reference pages for Building BI. > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts and widgets. ## Related reading * [Configure charts on a dashboard](/products/building-bi/dashboards#add-widgets-and-charts) * [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters) * [Chart styling options](/products/building-bi/reference/chart-styling-options) * [Choosing the right visualization](/products/building-bi/concepts/choosing-visualizations) # Color tools Source: https://docs.kodelabs.com/products/building-bi/reference/color-tools Apply series colors, gradients, ranges, and palettes on Building BI widgets, and manage organization palettes in Settings. Color controls live in the **Colors** section of a widget **Style** tab. See [Chart styling options](/products/building-bi/reference/chart-styling-options). Manage organization palettes in [Settings](/products/building-bi/settings#custom-color-palettes). ## Application methods | Method | Applies to | Notes | | - | - | - | | Series Colors | String and Boolean | Map a value to a color. Standardize meaning across dashboards. | | Gradient | Numeric | Between two values; optional middle color; can track min/max. | | Color Scheme | Categorical | KODE Labs pre-built sets. | | Color Palette | Categorical | Organization-built sets from Settings. | | Range | Numeric | Excludes the From value; includes the To value. Example: `(20 to 30) = green` → `30` is green, `20` is not. | Palette colors apply in list order (first value → first color). On some charts, data-label text switches white or black when gradient contrast is low. ## Palette management Palettes are portfolio-wide. | Action | Details | | - | - | | Create | Title, description, and at least 3–5 colors (HEX or RGB) | | Import | `.json` file, HEX only | | Edit | ⋮ menu: rename, reorder, add, delete | | Duplicate / Export | Copy a palette or export JSON for another organization | ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "name": "My New Theme", "dataColors": ["#FF5733", "#33FF57", "#3357FF", "#FFFF33"] } ``` ## Accessibility Check color-blind discernibility and text contrast. Adobe Contrast Checker and Color Blindness Simulator are recommended. ## Next steps > [card] [Custom color palettes](/products/building-bi/settings#custom-color-palettes) > > Create and manage palettes in Settings. > [card] [Chart styling options](/products/building-bi/reference/chart-styling-options) > > Look up Style tab options by chart type. # Data Source Types & Databases Source: https://docs.kodelabs.com/products/building-bi/reference/data-source-types Data Sources are the datasets Building BI draws from; every metric, calculation, and column originates from one. The Data Sources interface is opened from ... Use [Data sources](/products/building-bi/data-sources) to add and manage data sources. Data Sources are the datasets Building BI draws from; every metric, calculation, and column originates from one. The Data Sources interface is opened from the bottom of the left navigation panel. > [!WARNING] > > Global scope > Modifications in the Data Sources interface are **global** — they affect all dashboards across the entire portfolio, not a single building. Never delete a data source unless certain; deletion instantly breaks any dashboard relying on it. > [!NOTE] > > Name clash > See [Data Sources](/products/building-bi/data-sources) for the name distinction with Cloud BMS API integrations. ## Source types | Type | Description | Editable? | | - | - | - | | Physical | Direct data pulls from the backend. | Not directly editable as a table. | | Virtual | SQL-based views built on top of physical tables. | Editable via the ellipsis (⋮) on the far-right column of the table's row. | > [!NOTE] > > Virtual tables recompute on every query. Use them for light, real-time reshapes. Prefer physical tables when historical trending or heavy aggregation must stay fast. ## Database types The database type determines the SQL syntax required for custom logic. Three databases are used, each suited to a data type: | Database | Best for | Virtual Tables? | | - | - | - | | ClickHouse | Real-time sensor data | Yes — additional virtual tables can be created | | PostgreSQL | High-dimension (most columns) non-sensor data | Yes — additional virtual tables can be created | | BigQuery | Near-real-time backup; internal module tables (FTT, FDD, OSS, etc.) | **No** — virtual tables cannot be created | Calculated columns and metrics do not support window functions or aggregations of aggregations. Virtual table SQL can. See [Calculated fields](/products/building-bi/reference/calculated-fields). ## Data Sources table columns The Data Sources list page shows the following per row: | Column | Description | | - | - | | Type | Physical or Virtual. | | Database Type | ClickHouse, PostgreSQL, or BigQuery — indicates required SQL syntax. | | Management | ⭐ favorite frequently used tables; ⋮ menu to edit alias/description or (for virtual) edit SQL. | ## Adding a new data source Creating a new data source is uncommon; first try to solve problems with existing sources. Required fields differ by type: | Field | Physical | Virtual | | - | - | - | | Database Type | Required | Required | | Database Name | Required (ask Support/Data Analyst, or copy from another client) | Required | | Schema | Required (ask Support/Data Analyst, or copy from another client) | Required | | Table Name | Required | Required | | Display Name | Required | Required | | Description | Required | Required | | SQL Expression | — | Required (syntax depends on PostgreSQL vs ClickHouse) | ## Navigating a single data source Clicking a data source name opens its **Table Schema**, exposing four building-block types: **Columns** (native), **Calculated** (single-row logic), **Metrics** (multi-row aggregations), and **URLs**. See [Calculated Fields (Columns, Metrics & URLs)](/products/building-bi/reference/calculated-fields). | Action | Description | | - | - | | Sync Datasource | Pulls in the latest columns if the core KODE table changed. | | + Add Column | Creates calculated columns, metrics, or URLs. | | Check Usage | (⋮ menu) Identifies which dashboards use a column / whether a column is Unused. | | Optimization check | (⋮ menu) Checks whether a virtual table's SQL is optimized. | | Edit Data Source Details | (⋮ menu) Edit basic parameters and the virtual table SQL. | | Samples tab | Shows the \~20 most recent rows to verify structure and returned data. An `i` icon in a column header marks a calculated column; select it to open the query. | ## Optimization (virtual sources) Virtual sources that are not optimized can load slowly, error on large datasets, and cause similar performance issues. KODE OS offers AI-generated optimization suggestions (filters and the table to apply them to) shown beneath the current SQL Expression when editing details. Sources that are not optimized also surface a "Not Optimized" warning and appear flagged in the Setup-tab Data Source dropdown. ## Key sensor data sources | Data Source | Type | Description | | - | - | - | | Point Time Series Real-Time | Physical | Core sensor table; every reading is a new row; source of truth for building readings. ClickHouse-based. | | Point Time Series Last Value | Virtual | Returns only the most recent recorded value per sensor. Values may not share a timestamp. Useful for comparing current states across misaligned polling rates. | See [Table Structures & Polling Types](/products/building-bi/reference/table-structures) and [Point Time Series Column Reference](/products/building-bi/data-sources#column-reference). ## See also * The row-level structure of these tables: [Table Structures & Polling Types](/products/building-bi/reference/table-structures) * Every column in the sensor table: [Point Time Series Column Reference](/products/building-bi/data-sources#column-reference) * Building custom logic on a source: [Calculated Fields (Columns, Metrics & URLs)](/products/building-bi/reference/calculated-fields) * Task guide: [Data sources](/products/building-bi/data-sources) * Physical vs virtual sources: [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources) ## Next steps > [card] [Building BI overview](/products/building-bi/overview) > > Browse concept guides and reference pages for Building BI. > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts and widgets. ## Related reading > [card] [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources) > > Compare direct tables with derived virtual sources. > [card] [Key data sources](/products/building-bi/data-sources#key-data-sources) > > Choose Real-Time or Last Value Point Time Series sources. > [card] [Database types](/products/building-bi/data-sources#database-types) > > Understand ClickHouse, PostgreSQL, and BigQuery trade-offs. > [card] [Column reference](/products/building-bi/data-sources#column-reference) > > Look up column names for calculations and filters. # Filter options Source: https://docs.kodelabs.com/products/building-bi/reference/filter-options Filter types, operators by data type, and interaction widgets in Building BI. Building BI filters charts by column data type and by filter type. This reference lists operators for String, Numeric, DateTime, and Boolean columns. It also covers metric filters, Top N filters, and multi-widget filter behaviors. ## Filter types Standard filters apply to one chart in the Chart Parameters `Setup` tab. Cross filters, slicers, page filters, and dashboard filters can affect many widgets. Use `Edit Scope` to control which widgets a cross filter or slicer impacts. Configure page and dashboard filters in the `Filter` panel. A metric filter is an alternative to a standard filter. It keeps rows based on an aggregation such as `Sum`, `Count`, or `Max`. Bar, Line, Pie, Time Series, and Table charts also support a Top N filter. Top N limits the chart to the top or bottom N values in a column. Use it mainly for focus and styling. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart TB F["Filters in Building BI"] F --> S["Standard filter
one chart"] F --> M["Metric filter
aggregation + Show Value When"] F --> T["Top N filter
top or bottom N"] F --> X["Multi-widget filters"] X --> CF["Cross filter"] X --> SL["Slicer"] X --> PF["Page filter"] X --> DF["Dashboard filter"] ``` ## Operators by data type The filter UI adapts to the data type of the selected column. ### String `Starts with` · `Doesn't Start with` · `Ends with` · `Contains` · `Doesn't Contain` · `Equals` · `Not Equal` · `In` · `Not in` · `Is null` · `Is not null` · `Is blank` · `Is not blank` The null and blank operators take no value. The value input is hidden and `null` is sent to the backend. ### Numeric `Greater Than` · `Greater than or equals` · `Less than` · `Less than or equals` · `Between` · `Not between` · `Equals` · `Not equal` · `In` · `Not in` · `Is not a number` `Not between` treats both bounds as exclusive. `Is not a number` takes no value. ### Boolean `True` · `False` · `Is null` · `Is not null` ### Date and time Date and time filters offer these time-range types: | Type | Description | | - | - | | Current Date/Time | The in-progress period anchored on now. Unit: Day, Week, Month, Quarter, or Year. Includes today. | | Previous Date/Time | The completed prior period (Day, Week, Month, Quarter, or Year). Excludes today. | | Last Date/Time | A rolling window, such as last N days, ending at now. | | Specific Range with Granularity | A specific date or time compared with `Equals` at a chosen granularity, such as the month of `09-2023`. | | Relative Date/Time | A dynamic range from configurable `From` and `To` bounds (each Inclusive or Exclusive). From: `In the last`, `First day of the`, `Last day of the`. To: `Now`, `After from`, `First day of the`, `Last day of the`. Units: Minute and Hour for DateTime only; Day, Week, Month, Quarter, Year for Date and DateTime. | | Custom (legacy) | The pre-redesign combination filter. Existing Custom filters migrate to Relative Date/Time, then Custom is removed. | **Granularity options** for Specific Range with Granularity: * Date columns: Year, Year-Quarter, Year-Month, Year-Week, Quarter, Month, Week, Day of Year, Day of Month, Day of Week. * DateTime columns: all of the above plus Date, Date-Hour, Date-Half-Hour, Date-Hour-15min, Date-Hour-Minute, Hour, Minute. Minute and Hour units appear only for DateTime columns. See [Timezone configuration](/products/building-bi/reference/timezone-configuration) for how filter time ranges anchor to a timezone. > [!NOTE] > > Always check the actual time range shown at the bottom of the date-time filter configuration. That readout is the resolved range the query uses. ![Date-time filter dialog showing Timezone, Time Ranges, Type, and the Actual time range readout for Last 7 Days](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-filter-options-datetime-resolved-range.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=d098159f281ea4577fc51f0f71688146) Actual time range readout in the date-time filter ## Metric filters A metric filter keeps rows based on an aggregation of a column, not the raw column values. For example, keep devices where the count of alarms is greater than 10. Configure a metric filter in this order: 1. Choose an aggregation, such as `Count`, `Count Distinct`, `Sum`, `Min`, `Max`, or `Average`. 2. Set the `Show Value When` operator and value. `Show Value When` uses the same operators as a Numeric filter, including `Equals`, `In`, `Greater Than`, and `Is not a number`. For String columns, the available aggregations are `Count` and `Count Distinct` only. If you select a metric column instead of a raw column, Building BI skips the aggregation step. You configure only `Show Value When` and the operator. ## Top N filters | Input | Description | | - | - | | Category | The dimension to rank. | | Number of Items (N) | How many items to keep, plus a toggle for Top or Bottom. | | Value to sort by | The metric that determines ranking. | > [!NOTE] > > A standard visual set to show many items with scrolling can work better than a hard Top N. Viewers can still reach lower-ranked data without changing the filter. Label Top N cuts so viewers know data is hidden. Prefer Top N for glance-only displays; prefer scrolling (for example top 20 with a scrollbar) for interactive ops dashboards. ## Interaction widgets and behaviors | Feature | Description | | - | - | | Slicer | An on-canvas widget that holds a single-column filter and applies it within its scope. See [Slicer widget](/products/building-bi/reference/slicer-widget). | | Filter scopes (`Edit Scope`) | Defines which widgets and other filters a filter, slicer, or cross filter influences. By default, every filter affects all charts and filters on its page. See [Filter scope hierarchy](#filter-scope-hierarchy). | | Cross filter | Clicking a chart segment, such as a pie slice or bar, applies that segment as a temporary filter to the rest of the page. Toggle this in the chart filter section. | | Drill-through filters | Right-click a data point to open a target page or dashboard. Widgets on the target are auto-filtered by that selection. See [Drill-through filters](/products/building-bi/concepts/drill-through-filters). | ### Multi-widget filter matching Slicers and other multi-widget filters work across different data sources when the underlying database column names match exactly. Display names do not matter. For example, filtering on `device_name` in a Real-Time data source updates a Last Value widget when that source also uses the exact `device_name` column. Prefer ID columns such as `device_id` when names can change. See [Column reference](/products/building-bi/data-sources#column-reference). ### Filter interdependence Filters applied to a dataset restrict the options available in other filters. If a value is missing from a dropdown, current filter combinations have likely excluded it. > [!NOTE] > > If a target option is missing, remove other filters to expose the full dataset. You can also bypass the dropdown with a `Contains` filter and type the expected value. ### Filter scope hierarchy Which filter types can affect others, and which they can exclude from scope: | Filter type | Affects Dashboard filters | Affects Page filters | Affects Slicer filters | Affects Cross filters | | - | :-: | :-: | :-: | :-: | | Dashboard filters | ✓ | ✓ | ✓ | ✓ | | Page filters | ✓ | ✓ | ✓ | ✓ | | Slicer filters | | | ✓ | ✓ | | Cross filters | | | ✓ | ✓ | A filter can only exclude (scope out) filters at or below its own level. New widgets are affected by existing filters by default, so re-check exclusions as a dashboard grows. Use scopes when one widget must stay as an unfiltered reference (for example, a portfolio benchmark card) while a slicer updates the rest of the page. Excluded widgets also skip re-query when that filter changes. ![Edit Scope UI showing which widgets and filters a selected filter influences](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-filter-options-edit-scope.gif?s=aadd2d95ca5039a4052026bcc8499273) Edit Scope mapping for a filter ### Slicer filters A [slicer](/products/building-bi/reference/slicer-widget) holds one filter. The operator is fixed by the column data type: * String → `In` (single or multi-select) * Boolean → `Equals` (single select) * Number → `Between` (min/max slider) * Date/Time → Current, Previous, Last, or Specific Slicer selections persist as the dashboard's initial state. They are sent to the backend under `slicerFilters`. Dashboard, page, and cross filters can affect slicers. Slicers cannot be metric filters. ## Next steps > [card] [How filtering works](/products/building-bi/concepts/how-filtering-works) > > Understand how filters combine into one query and why dropdown options can disappear. > [card] [Drill-through filters](/products/building-bi/concepts/drill-through-filters) > > Jump from a summary chart to a detail view that opens already filtered. > [card] [Slicer widget](/products/building-bi/reference/slicer-widget) > > Configure the on-canvas filter control for a single column. > [card] [Dashboard filters](/products/building-bi/dashboards#dashboard-filters) > > Set dashboard and page filters in the Filter panel. # Keyboard shortcuts Source: https://docs.kodelabs.com/products/building-bi/reference/keyboard-shortcuts Select and bulk-edit widgets while editing a Building BI dashboard page. Use these shortcuts in edit mode. For the full bulk styling workflow, see [Widget customization](/products/building-bi/widget-customization#bulk-styling). ## Selection | Input | Action | | - | - | | Ctrl + A / Cmd + A | Select all widgets on the page | | Ctrl + click / Cmd + click | Add or remove a widget from the selection | | Widget `⋮` → `Select All Widgets on Page` | Select every widget | | Widget `⋮` → `Select All [Chart Type] Widgets on Page` | Select one chart type | ## Bulk actions | Action | Effect | | - | - | | Apply Default Styles | Applies the current default style (manual; not auto-propagated) | | Paste Styles on Selected | Applies a copied style to the selection | | Duplicate | Copies selected widgets | | Delete | Removes selected widgets | Single chart-type selections unlock general and chart-specific style options. Mixed selections unlock general options only. See [Chart styling options](/products/building-bi/reference/chart-styling-options). For the full walkthrough of bulk selection, default styles, copy and paste, and remove or duplicate, see [Widget customization](/products/building-bi/widget-customization#bulk-styling). # Shared links and scheduled reports Source: https://docs.kodelabs.com/products/building-bi/reference/shared-links-scheduled-reports Field reference for Building BI shared links and scheduled PDF reports, including IP rules and Settings management options. Field reference for Building BI shared links and scheduled PDF reports. Create either from a dashboard three-dot menu. Manage them across your portfolio in [Building BI settings](/products/building-bi/settings). ## Shared links A shared link is a URL that lets people outside KODE OS, or without a signed-in session, view a dashboard or widget. Recipients get a read-only interactive view. They can use charts and filters but cannot edit the dashboard. Create a dashboard link from the dashboard three-dot menu → `Share`. Create a widget link from the widget three-dot menu → `Share`. Both use the same field set. ![Sharing properties dialog showing Choose pages to share, Access Expiration, Link title, Refresh rate set to None, Allowed IP addresses set to wildcard, Active and Expired tabs, and Cancel and Generate Link buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-share.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=045755421c41ed2c3d851b0d29b63646) Sharing properties dialog with pages, expiration, refresh rate, and IP restrictions > [accordion] Create a shared link > > 1. Open the dashboard or widget three-dot menu and select `Share`. > 2. Set pages, expiration, link title, refresh rate, and allowed IP addresses. > 3. Select `Generate Link`, then select the link icon to copy the URL. > > Full steps live in [Share dashboards and widgets](/products/building-bi/dashboards#share-dashboards-and-widgets). ### Share fields **Pages to share** `Field` Select which dashboard pages the link exposes. Choose all pages or a subset. **Expiration** `Field` Set when access ends. Choose `Never` for no expiration. **Link Title** `Field` Label used to find and manage the link. Titles do not need to be unique. **Refresh Rate** `Field` How often the shared view refreshes with new data. Defaults to `None`. More frequent refresh uses more compute, so prefer longer intervals when possible. **Allowed IP addresses** `Field` Restricts access by IPv4 address. Leave blank or enter `*` to allow all addresses. Only the dashboard owner can edit this field. ### IP address rules | Rule | Behavior | | - | - | | Allowed list | The request IP must match an allowed address | | Blank or `*` | All IP addresses are allowed | | Disallowed IP | Returns HTTP `403` and does not show content | | Visibility | Only the owner sees IP values; others see that restrictions exist | ### Manage shared links In [Settings](/products/building-bi/settings#shared-links), use the `Active` and `Expired` lists. Edit or delete a link from the three-dot menu. You can also manage links from the `Active` and `Expired` tabs in the share dialog. ## Scheduled reports A scheduled report is a recurring PDF export emailed to recipients. Create one from the dashboard three-dot menu → `Schedule PDF Report`. ![Schedule PDF Report dialog showing Create Schedule tab with Name, Pages set to All pages selected, Subject, Export data with current filter modifications checked, From date, Time, Timezone set to UTC, Frequency, Recipients, Ends set to Never, and Cancel and Schedule buttons](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-dashboards-schedule-pdf.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=db9ad4b12d30ac59ef38234dfc6f01b8) Schedule PDF Report dialog on the Create Schedule tab > [accordion] Create a scheduled report > > 1. Open the dashboard three-dot menu and select `Schedule PDF Report`. > 2. On the `Create Schedule` tab, complete the schedule fields. > 3. Select `Schedule` to activate delivery. > > For one-time exports and full schedule steps, see [PDF exports and scheduled reports](/products/building-bi/pdf-exports). ### Schedule fields **Name** `Field` Identifier for the schedule in Settings and the schedule list. **Pages** `Field` Dashboard pages included in the PDF. Choose `All pages selected` or specific pages. **Subject** `Field` Email subject line for each delivery. **Export data with current filter modifications** `Toggle` When enabled, the exported PDF reflects the current dashboard filter state. Pinned filters are not included. **From / Time / Timezone** `Field` Sets the first delivery date, time of day, and timezone. Later sends follow this start time on the chosen frequency. **Frequency** `Field` How often the report repeats after the start time, such as daily, weekly, or monthly. **Recipients** `Field` One or more email addresses. Recipients must have a KODE Labs account. **Ends** `Field` Choose `Never` for an indefinite schedule, or `On` to set an end date. ### PDF export limits > [!WARNING] > > PDF export cuts off content that requires scrolling. Check widget sizes when you test so data is not lost. Run a [test PDF export](/products/building-bi/pdf-exports#export-a-dashboard-as-pdf) before you create a scheduled report. Tooltips and dynamic filters often do not appear well in PDF output. Prefer layouts that show critical values without hover or scroll. Scheduled report emails include a PDF attachment and a live link to the dashboard. ### Manage scheduled reports In [Settings](/products/building-bi/settings#scheduled-reports), use the `Enabled` and `Disabled` lists. Edit or delete a schedule, or toggle status to pause delivery before the end date. You can also manage schedules from the `Schedules` tab in the schedule dialog. ## Next steps > [card] [Share dashboards and widgets](/products/building-bi/dashboards#share-dashboards-and-widgets) > > Create shareable links for live dashboard or widget views. > [card] [PDF exports and scheduled reports](/products/building-bi/pdf-exports) > > Export PDFs and schedule recurring report delivery. > [card] [Settings](/products/building-bi/settings) > > Manage shared links and schedules across your portfolio. > [card] [How permissions work](/products/building-bi/concepts/how-permissions-work) > > Understand view access, edit access, and collaborators. # Slicer widget Source: https://docs.kodelabs.com/products/building-bi/reference/slicer-widget Configure Building BI slicers by column type, display mode, and interaction rules. A slicer is an on-canvas filter bound to a **single column**. Viewers change the selection; widgets in scope re-query. Configure one from [Dashboard filters](/products/building-bi/dashboards#dashboard-filters). For operators and scope, see [Filter options](/products/building-bi/reference/filter-options). ## Setup | Field | Description | | - | - | | Filter | Required. One column. String columns load distinct values; number columns load min/max. | | Sort | Optional ascending or descending order. | | Filters | Optional chart-level filters, as on any widget. | A slicer cannot be a metric filter. ## Behavior by column type | Column type | Operator | Selection | Notes | | - | - | - | - | | String | `IN` | Single or multi | Multi can include Select All | | Boolean | `EQUALS` | Single only | Not affected by other slicers or cross-filters | | Number | `BETWEEN` | Min/max range | Bounds load with the widget | | Date / Time | Current, Previous, Last, Specific | Per type | See date table | ## Display options | Property | Options | | - | - | | String | Dropdown or Flat; Single or Multi | | Boolean | Dropdown or Flat (tiles) | | Date | Specific, Last, Previous, or Current — each as Dropdown or Flat | | Values | Font styling; row padding when Flat | | General | Same general style options as other widgets | ### Date defaults | Type | Default | Dropdown | Flat | | - | - | :-: | :-: | | Specific | Other date | Yes | Yes | | Last Date/Time | Last 7 days | Yes (single) | Yes (single) | | Previous Date/Time | Previous Week | Yes (single) | Yes (single) | | Current Date/Time | Current Week | Yes (single) | Yes (single) | ## Interaction rules * Selections saved in edit mode become the published defaults. * Dashboard filters, page filters, and cross-filters affect slicers. * Boolean slicers ignore other slicers and cross-filters. * Apply on selection, or behind an **Apply** button. ## Next steps > [card] [Filter options](/products/building-bi/reference/filter-options) > > Look up operators and filter scopes. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Find the slicer in the widget catalogue. # Table structures and polling Source: https://docs.kodelabs.com/products/building-bi/reference/table-structures Understand how Building BI time-series sources record rows, including COV, structured pulls, and aggregated polling. Choose a time-series source in [Data sources](/products/building-bi/data-sources#key-data-sources). Polling behavior is usually implied by the source name (Real-Time, Last, Hourly, Daily). Every point time-series table holds **one row per point per time period**, plus building, area, and device context. The same device can produce multiple rows at one timestamp — one per point. ## Primary structures | Structure | Type | Behavior | | - | - | - | | Point Time Series Real-Time | Physical (ClickHouse) | Every reading is a new row. Full history. | | Point Time Series Last Value | Virtual | Most recent value per sensor. Timestamps may differ. | Use Last Value to compare current state across sensors with misaligned poll rates. See [Real-Time vs Last Value](/products/building-bi/data-sources#key-data-sources). ## Polling types | Polling type | Behavior | | - | - | | Change of Value (COV) | New row when the value changes past the COV threshold, with a **1-hour maximum** between rows | | Structured Data Pull | One row per interval (for example every 1, 5, or 15 minutes) | | Aggregated (for example Hourly) | Sum, Min, Max, Avg, or Count per point per period | Aggregation suits some points and not others. Hourly average air temperature is useful; aggregated elevator floor level is not. Prefer reduced-frequency sources over Real-Time only when load time is a concern. ## Next steps > [card] [Key data sources](/products/building-bi/data-sources#key-data-sources) > > Pick Real-Time, Last Value, or reduced-frequency sources. > [card] [Column reference](/products/building-bi/data-sources#column-reference) > > Look up Point Time Series column names. # Template types Source: https://docs.kodelabs.com/products/building-bi/reference/template-types Compare Building BI collection, dashboard, page, and chart templates, including scope, sharing, and Building Data Hub dependencies. Use [Templates](/products/building-bi/templates) for create and apply steps. For parity across sites, use the [Deployment manager](/products/building-bi/deployment-manager) instead. See [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ## Scope | Level | Owned by | Edited by | Visible to | | - | - | - | - | | KODE / Global | KODE Labs | KODE Admins only | Every workspace (read-only) | | Organization | Organization or channel partner | Org Admins, or Manage Templates | Everyone in that organization | | Action | Org Admin / Manage Templates | KODE Admin | | - | :-: | :-: | | Create, edit, delete org template | Yes | Yes | | Create, edit, delete global template | — | Yes | | Use, share, or import | Yes | Yes | ## Object types | Type | Captures | Saved under | Used from | | - | - | - | - | | Collection | A group of dashboards | Organization Templates | Templates → Collection Templates | | Dashboard | One dashboard | Organization Templates | Templates → Dashboards | | Chart | One widget | Charts – Organization Templates | Edit mode → Chart Library | | Page | One page (widgets, layout, filters, settings) | Page Templates / Pages tab | Inserts at end of the current dashboard's pages | Page templates require Can Edit. Card ⋮ menu supports Edit, Export (24-hour link), and Delete. Import auto-detects `page` type. ## Share and import | Action | Details | | - | - | | Share / Export | ⋮ → Share Template. Secure URL expires after **24 hours**. | | Import | Templates page → Import. Clones into Organization Templates with full local edit rights. | ## Building Data Hub dependencies Some templates need Building Data Hub pipelines. | Step | Detail | | - | - | | Set Dependencies | On save: data sources (required), pipelines (required for BDH metrics), canonical and ontology fields (optional) | | Dependency Map | Collections schedule a shared pipeline once | | Enable | Side sheet lists pipelines; Enable opens Building Data Hub with scheduling pre-filled | Portfolio dashboard template use prompts for a [timezone](/products/building-bi/reference/timezone-configuration) (UTC if omitted). Building-level dashboards inherit the building timezone. ## Next steps > [card] [Templates](/products/building-bi/templates) > > Create, apply, share, and import templates. > [card] [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment) > > Choose independent copies versus governed parity. # Timezone configuration Source: https://docs.kodelabs.com/products/building-bi/reference/timezone-configuration Set the timezone that anchors Building BI date and time filters so relative ranges resolve in local time. Set a timezone when you [create a dashboard](/products/building-bi/dashboards#create-a-dashboard). Without one, date and time filters resolve against UTC, so buildings in other zones can miss part of ranges like "today." | Scope | Default | Editable | | - | - | - | | Dashboard (portfolio) | UTC | Create dialog; edit mode | | Dashboard (building) | Building timezone | Edit mode | | Filter (dashboard, page, or widget) | Dashboard timezone | Edit mode only | | Slicer (date/time columns) | Dashboard timezone | Optional override on the slicer | | Dashboard template use (portfolio) | UTC if omitted | Prompted on use | You cannot change a date/time filter timezone in view mode. ## Next steps > [card] [Create a dashboard](/products/building-bi/dashboards#create-a-dashboard) > > Pick a timezone when you create the dashboard. > [card] [Filter options](/products/building-bi/reference/filter-options) > > See the date filter types this setting anchors. # Building BI settings Source: https://docs.kodelabs.com/products/building-bi/settings View and manage shared links, scheduled reports, custom color palettes, and templates from the Building BI Settings page. The Building BI settings page gives you a centralized view of all [shared links and scheduled reports](/products/building-bi/reference/shared-links-scheduled-reports), [custom color palettes](/products/building-bi/reference/color-tools), and templates across your dashboards. ## Access settings Navigate to `Building BI` and click `Settings` at the bottom of the page. ## Shared links The `Shared Links` tab displays all generated links for your dashboards. Use the search bar and `Active`/`Expired` filters to find specific links. Select one or more links using the checkboxes to delete them in bulk. ![Settings page Shared Links tab showing a table with Link Title, Expires, Building Name, Dashboard, Entity Type, Refresh Rate, and Allowed columns listing seven shared links with values like Enter Tenant Name expiring Never with 60 Minutes refresh and All IPs allowed, with two rows selected and Cancel and Delete buttons at the bottom](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-shared-links.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=b3bda7412dfbc3be742ef61bacb848d4) The Shared Links tab showing active links with expiration, dashboard, refresh rate, and IP access details Each entry shows the following details: | Field | Description | | - | - | | **Expiration** | When the shared link expires | | **Building Name** | The building associated with the dashboard | | **Refresh Rate** | How often the shared view refreshes with new data | | **Allowed IPs** | IP addresses permitted to access the link | ### Edit a shared link **1. Open the edit dialog** Click the three-dot menu on the shared link and select `Edit`. **2. Modify link settings** Update any of the following fields: * **Pages to share** -- Select which dashboard pages are included in the link. * **Link Title** -- Update the display name for the shared link. * **Refresh Rate** -- Change how frequently the shared view refreshes. * **Allowed IPs** -- Restrict access to specific IP addresses. **3. Save your changes** Click `Save` to apply the updated settings. > [!NOTE] > > Changing the `Allowed IPs` field requires dashboard ownership. Contact the dashboard owner if you need to modify IP restrictions. ### Delete a shared link Click the three-dot menu on the shared link and select `Delete`. This revokes access for anyone using the link. ## Scheduled reports The `Scheduled Reports` tab lists all active and paused report schedules across your dashboards. Use the search bar and `Enabled`/`Disabled` filters to find specific reports. ![Settings page Scheduled Reports tab showing a table with Name, Building Name, Frequency, Dashboard, End Date, and Status columns listing four reports including Weekly Report Summary, 1350 Weekly Smart Building Report, OSS Report Summary, and Kode Labs Test with enabled status toggles](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-scheduled-reports.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=688836298a8e6e960925f4ff4bc71017) The Scheduled Reports tab showing report schedules with frequency, dashboard, and status columns Select one or more reports using the checkboxes to access bulk actions. Select `Delete` to remove the selected schedules. ![Scheduled Reports tab with two reports selected showing checkboxes, Building Name column visible, and Cancel and Delete buttons at the bottom](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-scheduled-reports-select.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=a5d03e867dcf627d61a9015c48f84931) Selecting multiple scheduled reports for bulk deletion ### Edit a scheduled report Select the three-dot menu on any report and select `Edit`. You can modify the report name, included pages, frequency, repeat interval, recipients, and other schedule settings. ### Delete a scheduled report Select the three-dot menu on the report and select `Delete`. This permanently removes the schedule and stops all future deliveries. ## Custom color palettes Organization-level color palettes are managed from the `Color Palettes` tab. Create reusable palettes for branding, themes, or visualization contexts and apply them across all Building BI dashboards in your portfolio. See [color tools](/products/building-bi/reference/color-tools) and [dashboard styling principles](/products/building-bi/widget-customization#styling-best-practices) for selection and usage guidance. Centralized palettes reduce ad-hoc color choices and help teams maintain a consistent visual identity across charts, backgrounds, markers, and other widget elements. ![Settings page Color Palettes tab showing Active and Archived filters, Import button, New Palette button, and two palette cards: Asset Ops Colours with multiple color swatches and Asset Ops Team Colours with five color swatches](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-color-palettes.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=1e93125f07077ef613843e3ab602a614) The Color Palettes tab showing custom organization palettes with color swatches Use the `Active`/`Archived` toggle to filter palettes by status. Select `Import` to upload a previously exported palette, or select `+ New Palette` to create one. ### Create a palette Select `+ New Palette` and configure the palette details. ![Create Palette dialog showing Name field set to Dark Theme, Description field, Palette Colors section with Add a Color button, and two color entries Color 1 in black and Color 2 in dark red with drag handles and remove buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-create-palette.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=89edf748829430d97ae640910178244e) The Create Palette dialog with name, description, and color entries | Field | Description | | - | - | | `Name` | Display name for the palette | | `Description` | Optional description of the palette purpose | | `Palette Colors` | List of colors in the palette. Select `+ Add a Color` to add entries. Drag the handles to reorder colors. | Select `Create` to save the palette. ### Manage a palette Select the three-dot menu on a palette card to access management actions. ![Color palette card three-dot menu showing Edit, Duplicate, Export, and Archive options for the Asset Ops Colours palette](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-settings-palette-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=e98ec8a610faf578c9fc10288be1d485) Palette card three-dot menu with Edit, Duplicate, Export, and Archive options | Action | Description | | - | - | | `Edit` | Modify the palette name, description, or colors | | `Duplicate` | Create a copy of the palette | | `Export` | Download the palette for use in other portfolios | | `Archive` | Move the palette to the archived list | Color palettes created here appear as options in the `Colors` section of any widget style configuration. Unlike the predefined color schemes provided by KODE Labs, custom palettes are designed and maintained by your organization. ## Templates The `Templates` page is accessible from the bottom of the left navigation panel. See [Templates](/products/building-bi/templates) for full documentation on saving, importing, exporting, and applying templates. ## Related reading > [!NOTE] > > For export and schedule workflows, see [PDF exports and scheduled reports](/products/building-bi/pdf-exports). For field-level details, see [Shared Links and Scheduled Reports](/products/building-bi/reference/shared-links-scheduled-reports). For who can share or schedule, see [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). > [card] [Widget customization](/products/building-bi/widget-customization) > > Style widgets, apply defaults, manage palettes, and add graphics. > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Match chart types to the question you need to answer. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup requirements for every widget type. > [card] [Color tools](/products/building-bi/reference/color-tools) > > Configure series colors, gradients, and palettes. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts, tables, and widgets. > [card] [PDF exports](/products/building-bi/pdf-exports) > > Export dashboards as PDF files and schedule automated reports. # Templates Source: https://docs.kodelabs.com/products/building-bi/templates Save, import, export, and apply reusable Building BI templates for collections, dashboards, pages, and charts across buildings and portfolios. Templates let you save and reuse Building BI configurations across buildings and portfolios. You can template collections, dashboards, individual pages, or single charts and apply them to any compatible building. > [!NOTE] > > Navigate to `Building BI` and select `Templates` at the bottom of the left navigation panel. See [template levels](/products/building-bi/reference/template-types), [templating versus deployment](/products/building-bi/concepts/templating-vs-deployment), and [template types](/products/building-bi/reference/template-types) to choose the right reuse strategy. ## Template types Templates are organized into four categories. Use the filter buttons at the top of the page to switch between them. | Type | Description | | - | - | | `Collections` | A full collection including its dashboards, pages, charts, and data source dependencies | | `Dashboards` | A single dashboard with all its pages, charts, and data source dependencies | | `Pages` | An individual dashboard page with its charts and layout | | `Charts` | A single chart widget with its data source configuration and styling | > [!TIP] > > The `Title` and `Template Type` fields are populated automatically when you save or import a template. You do not need to set the template type manually. > [tab] Collections > > Collection templates include all contained dashboards and their data source dependencies. > > ![Templates page with Collections filter selected showing Organization Templates with collection template cards each listing their contained dashboards such as Operations Dashboard, Lighting Occupancy, Occupancy Report, and Network Health](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-collections.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=d6d69b96a17bcb13448faa634c8ad3f8) > > Collections filter showing collection templates with their contained dashboards > [tab] Dashboards > > Dashboard templates include all pages, charts, and data source configurations within a single dashboard. > > ![Templates page with Dashboards filter selected showing Organization Templates with dashboard template cards for Comfort and Air Quality, Copy of Lighting, Lighting, Operations, Site Summary, and more](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-org.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=af42c8b5b612730df11bddab9ea5201d) > > Dashboards filter showing individual dashboard templates > [tab] Pages > > Page templates capture the layout and chart configuration of a single dashboard page. > > ![Templates page with Pages filter selected showing Organization Templates with page template cards for Runtime, Building Metrics, and Overview](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-pages.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=fb91226e9d88a78264cfdf0b83e757f4) > > Pages filter showing individual page templates > [tab] Charts > > Chart templates save a single widget with its chart type, data source, and styling. Each card displays the chart type below the template name. > > ![Templates page with Charts filter selected showing Organization Templates with chart template cards for Estimated Emissions by as Horizontal Bar, Usage Breakdown by Ser as Horizontal Bar, Zone Temperature vs Eff as Combo, Occupied AHUs as Number Target, and Occupied FCUs as Number Target](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-charts.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=673c1cea2aef03840a31b0e46684038c) > > Charts filter showing individual chart templates with their chart types ## Organization templates The `Organization Templates` tab displays templates created by your organization. These templates are available to all users with Building BI access in your portfolio. ![Templates page showing Organization Templates tab with Dashboards filter selected, displaying template cards for Comfort and Air Quality, Copy of Lighting, Lighting, Operations, Site Summary, Lighting and Occupancy, Parking Occupancy, Traffic and Occupancy, Comfort and Air Quality, and more with descriptions and last updated timestamps](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-org.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=af42c8b5b612730df11bddab9ea5201d) Organization Templates showing saved dashboard templates with descriptions and timestamps ### Manage a template Select the three-dot menu on any organization template to access management actions. ![Template card three-dot menu showing Use template, Edit, Export, and Delete options for the Comfort and Air Quality template](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=dea6eb1401c044b5fa5816c2002d88df) Template three-dot menu with Use template, Edit, Export, and Delete options | Action | Description | | - | - | | `Use template` | Create a new dashboard or collection from this template | | `Edit` | Modify the template name, description, or configuration | | `Export` | Generate a shareable link to transfer the template to another portfolio | | `Delete` | Permanently remove the template | ## Global templates The `Global Templates` tab provides standard templates maintained by KODE Labs. These templates are available to all organizations and cover common use cases such as network health, operations, energy reporting, and data quality. ![Templates page showing Global Templates tab with an info banner stating Global Templates cannot be edited or deleted, displaying template cards for Impact Report, Overrides, Device Alarms, Data Quality, Network Health, SH PRISM CMMS DAS, Network Health and Data Q, Travis QA Tools, Portfolio Executive Over, Operation Dashboard Wi, and more](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-global.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=f9ece72db1c82160ef5904abc0ff4fc8) Global Templates showing KODE Labs standard templates available to all organizations > [!NOTE] > > Global templates cannot be edited or deleted. You can use them to create new dashboards, or export them to share the link with other portfolios. ## Save as template You can save collections and dashboards as templates directly from the `Collections & Dashboards` page. ### Save a collection as a template **1. Open the collection menu** Navigate to `Collections & Dashboards`. Select the three-dot menu on a collection and choose `Save As Template`. ![Collections page showing a published Dashboard Collection with its three-dot menu open displaying Unpublish, Edit Collection, Manage Viewers, Save As Template, and Delete options](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-collection.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=df6571022848c46612c6814f790b671d) Collection three-dot menu with the Save As Template option **2. Enter template details** Enter a `Template Name` and an optional `Description`. Select `Save Now` to save the template immediately, or select `Next` to configure dependencies. ![Save as Template dialog Step 1 Template Details showing a four-step wizard with Template Details, Set Dependencies, Canonicals and Fields, and Review and Confirm steps, with Template Name set to Dashboard Collection and a Description field](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-details.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=901727a77d871277c70264448ce2339e) Step 1: Template Details with template name and description fields **3. Set dependencies** Select which data source dependencies to include with the template. Expand each data source to see its pipelines and graphs. Check or uncheck individual items to control what is bundled with the template. ![Save as Template dialog Step 2 Set Dependencies showing Timeseries Last Values Pivoted with Point Time Series Last Values checked, Point Metrics with Running Minutes Metrics checked and two graph items, and an Updated Version item unchecked](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-dependencies.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c851486556e87f13e68cd17c836d1f99) Step 2: Set Dependencies showing data sources and their pipelines **4. Configure canonicals and fields** Select the canonical types and ontology fields that define how the template maps to building data. When you later deploy the template, Building BI flags any required canonical or ontology field that is missing at the target building or portfolio. **5. Review and confirm** Review the template configuration and select `Save Now` to finalize. ### Save a dashboard as a template Navigate to `Collections & Dashboards`. In the `My Dashboards` table, select the three-dot menu on a dashboard and choose `Save as template`. The same four-step wizard opens. ![Collections and Dashboards page showing the My Dashboards table with a dashboard three-dot menu open displaying Edit, Duplicate, Permissions, Save as template, and Delete options](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-dashboard.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=299680bdce4acda03a65d702e2c37f5a) Dashboard three-dot menu with the Save as template option ### Save a chart as a template You can save individual charts as templates while editing a dashboard. **1. Open the chart menu** Enter edit mode on a dashboard. Select the three-dot menu on any chart widget and choose `Save as Template`. ![Dashboard in edit mode showing a chart widget three-dot menu with Duplicate, Copy to, Copy Style, Paste Style, Save as Template, Select All, and Delete options](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-chart-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=5066e574745cda814ac92c5a23e2e3d0) Chart widget three-dot menu with the Save as Template option **2. Enter template details** Enter a `Template Title` and an optional `Description`. Select `Save` to add the chart to your organization templates. ![Save as template dialog showing Template Title set to Zone Temperature vs Effective Setpoints, a Description field, and Cancel and Save buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-chart-dialog.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=3d7b4f8076f3138c4536f256c8fd75cd) Save as template dialog with Template Title and Description fields ### Save a page as a template You can save individual dashboard pages (tabs) as templates while editing a dashboard. **1. Open the page menu** Enter edit mode on a dashboard. Select the three-dot menu (`...`) next to the page tab name and choose `Save as Template`. ![Dashboard in edit mode showing the Floor Overview page tab three-dot menu with Duplicate, Save as Template, and Delete options](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-page-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=2d58721ec51ff216e65e80b059c1684c) Page tab three-dot menu with Duplicate, Save as Template, and Delete options **2. Enter template details** Enter a `Page Name` and an optional `Description`. Select `Save` to add the page to your organization templates. ![Save as template dialog showing Page Name set to Floor Overview, a Description field, and Cancel and Save buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-save-page-dialog.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c6b139d3c8e86b149f0eae9528dbc2b2) Save as template dialog with Page Name and Description fields ## Template Library The Template Library is a side panel available in dashboard edit mode. It lets you add chart and page templates directly to the dashboard you are editing. **1. Open the Template Library** Enter edit mode on a dashboard. Select the `Template Library` button in the right sidebar. ![Dashboard in edit mode showing the right sidebar with the Template Library button highlighted](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-library-button.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=716432db0837dc1d7f8f3ec98f232cc9) The Template Library button in the dashboard edit sidebar **2. Select a template type** Use the dropdown at the top of the panel to switch between `Charts` and `Pages`. Switch between the `Organization Templates` and `Global Templates` tabs, or use the search bar to find a specific template. ![Template Library panel with the type dropdown open showing Charts and Pages options, with Pages selected and Organization Templates tab displaying Runtime, Building Metrics, and Overview page templates](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-library-pages-filter.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=ae5118633a7ead437b2b37bfdf8ff567) Template Library type dropdown with Charts and Pages options **3. Add a chart template** With `Charts` selected, drag a chart template from the library panel and drop it onto the dashboard canvas. The chart is added with its preconfigured data source, chart type, and styling. ![Template Library panel with Charts filter selected showing Organization Templates tab with chart templates including Estimated Emissions by Service Type, Usage Breakdown by Service Type, Zone Temperature vs Effective Setpoints, Occupied AHUs, and Occupied FCUs](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-library-panel.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=5b0f8abcba3594175802e97a05e2e8c2) Template Library panel showing available chart templates **4. Add a page template** With `Pages` selected, hover over a page template and select `Use`. The page is added as a new tab in the dashboard. ![Template Library panel with Pages filter selected showing Organization Templates with Runtime, Building Metrics, and Overview page templates, with a Use button visible on the Runtime template](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-library-pages-use.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=67fa12e87f5277da3f83a1b625e154c3) Template Library with Pages selected showing the Use button on a page template ## Use a template Apply a template to create a new dashboard or collection in your current building. > [!WARNING] > > **Deployment risk:** Deployed dashboards retain the data filters, chart configurations, and settings defined on the host building's dashboard. If the target buildings do not contain the same data, equipment, naming conventions, or configuration, some charts may return errors or no data. Before deploying, confirm that all selected buildings support the dashboard's requirements. **1. Select the template** Select the three-dot menu on a template and choose `Use template`. **2. Set template details** Enter a `Dashboard Name`, select a `Timezone`, and add an optional `Description`. Select `Use Now` to create the dashboard immediately, or select `Next` to review dependencies. ![Use Template dialog Step 1 Template Details showing Dashboard Name set to Comfort and Air Quality, Timezone set to America/Detroit minus 04:00, Description field, and Cancel, Use Now, and Next buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-use-details.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=99750f748603506ef4481d4d0bf189cb) Step 1: Template Details with dashboard name, timezone, and description fields **3. Enable dependencies** Review the data source dependencies required by the template. Select `Enable` next to each dependency to activate it for the target building. If a dependency does not exist in your organization, an info banner explains that it cannot be scheduled. ![Use Template dialog Step 2 Enable Dependencies showing an info banner about imported templated dependencies not existing in this organization, Point Metrics section with Template Running Minutes Metrics and Enable button, and two graph items Graph Running Minutes Point Per Start and Graph Running Minutes by Point](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-use-dependencies.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=793fb7f774bbc0a8bb58d5c3da3301ca) Step 2: Enable Dependencies showing required data sources and their status **4. Configure canonicals and fields** Select the canonical types and ontology fields the template requires. These determine how the template maps to the target building's data model. Building BI validates each selection against the building or portfolio you are deploying to. If a required canonical type or ontology field does not exist there, the deployment windows flags it. Use that feedback as a QA check before you finish deploying the collection or dashboard. ## Export a template Export a template to share it with another portfolio. 1. Select the three-dot menu on a template and choose `Export`. 2. The system generates a link and copies it to your clipboard. ![Export Link Generated notification stating Link has been copied to your clipboard and Use the import button to import your template](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-export-toast.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=050f636375b532964959245b6a9c5ba3) Export confirmation showing the link has been copied to the clipboard Share the copied link with the recipient. They can import it using the `Import Template` button in their own Templates page. ## Import a template Import a template from another portfolio using an exported link. **1. Open the import dialog** Select `Import Template` in the upper-right corner of the Templates page. **2. Paste the template link** Paste the exported template URL into the `Import URL` field. The `Title` and `Template Type` fields populate automatically from the link. ![Import dialog showing Import URL field with Paste here placeholder, Title field, Template Type field populated automatically, Description field, and Cancel and Save Template buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-templates-import.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=7140a737cfda6e1b3afb3546bd9e3959) The Import dialog with URL, title, type, and description fields **3. Save the template** Review the auto-populated details and select `Save Template`. The template appears in your `Organization Templates` tab. ## Related reading > [card] [Collections](/products/building-bi/collections) > > Control visibility and organize dashboards by audience. > [card] [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment) > > Choose independent copies or governed portfolio parity. > [card] [Template types](/products/building-bi/reference/template-types) > > Compare collection, dashboard, page, and chart templates. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboards and manage predefined versus custom views. ## Next steps > [card] [Collections](/products/building-bi/collections) > > Organize and publish dashboard collections for your teams. > [card] [Deployment manager](/products/building-bi/deployment-manager) > > Deploy dashboard configurations across multiple sites in your portfolio. # Build your first dashboard Source: https://docs.kodelabs.com/products/building-bi/tutorials/build-your-first-dashboard Build a Down Devices Building BI dashboard with Number (Target), bar, line, and pivot table widgets. Building BI ## Build your first dashboard Create a building-level Down Devices dashboard with a Number (Target) widget, bar chart, line chart, and pivot table. Beginner About 30 min ![Completed Down Devices dashboard with Number (Target), bar chart, line chart, and pivot table widgets](/images/kode-os/building-bi/bbi-tutorial-final-layout.png) Progress /
    Step 0 ### Enable Building BI for your organization ![Building BI appearing in the left navigation after the module is enabled](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-enable-building-bi.gif?s=d73d52511a6c551b32c3643deb19072e) Confirm that Building BI is available in the left navigation and that your role can open the module. Enable Building BI on the building `Modules` tab in Launchpad. KODE Support often does this for your organization. If you cannot see `Building BI`, contact [support@kodelabs.com](mailto:support@kodelabs.com) or ask your customer success manager (CSM). You can submit this as a support request or bug report. After the module is available, your role still needs the right permissions. See [Enable Building BI](/products/building-bi/overview#enable-building-bi) and [How Building BI permissions work](/products/building-bi/concepts/how-permissions-work). Step 1 ### Create a new dashboard ![New Dashboard dialog showing Down Devices as the title, a description field, and a timezone selector](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-create-dashboard.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=757423ca76f8c11f95d0153dd318df63) Create an empty building-level dashboard. You fill it with widgets in the next steps. **1. Open the New Dashboard dialog** Open `Collections and Dashboards` and select `+ New Dashboard`. **2. Choose the building level** Create the dashboard at the **building** level, not the portfolio level. Building-level dashboards scope to one building. **3. Name the dashboard** In the popup, set the name to `Down Devices`. **4. Add a description** Enter a short description such as `Track currently down devices by type, trend, and device detail.` **5. Set the timezone** Set the timezone to your building's timezone. See [Timezone configuration](/products/building-bi/reference/timezone-configuration). **6. Create the dashboard** Select `Create`, then open the dashboard and enter edit mode. Step 2 ### Add a Card widget Widget data can come from many sources. For this walkthrough, use two standard sources that appear in most KODE deployments: * [`Point Time Series Last Value Aggregated`](/products/building-bi/data-sources#key-data-sources) — last value each point reported. Use this so devices with different report intervals still appear. * [`Point Time Series Real Time`](/products/building-bi/data-sources#key-data-sources) — raw updates as soon as KODE receives them. Start with a [Card](/products/building-bi/reference/chart-types#card) that shows one value: the count of currently down devices. **1. Drag a Card onto the canvas** From the chart list, drag a `Card` onto the canvas. Resize it as needed. ![Dragging a Card chart from the chart list onto the dashboard canvas](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-drag-card.gif?s=98d2febdcbf1a05e8d3fb2ac897fd61e) **2. Choose the data source** Open the `Setup` tab. Select `Point Time Series Last Value Aggregated` so you read the last known device status. **3. Set the value** Set the value to the `device_id` column. Use **count distinct**. This counts unique devices. Count distinct is best practice even when each row should have one value. **4. Filter to down devices** Filter with the `cur_status` column. Set the operator to `in` and the value to `down`. See [Filter options](/products/building-bi/reference/filter-options). **5. Add a description** Open the `Style` tab. In `Description`, type `Currently Down Devices`. See [Chart styling options](/products/building-bi/reference/chart-styling-options#general). Your Card should look like this: ![Card widget on the canvas showing a count of down devices with the Currently Down Devices description](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-card-widget.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=89b091a7dedef1b0047b622a79d97c66) Step 3 ### Upgrade the Card to Number (Target) ![Number (Target) widget showing down devices over total devices with Currently Down Devices as the description](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-number-target.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=8870c925237cd6651fb26bdd30b11c0d) Convert the Card into a [Number (Target)](/products/building-bi/reference/chart-types#number-target) widget. The primary value stays filtered to down devices. The target shows the total device count for context. **1. Change the chart type** In `Setup`, change the chart type from `Card` to `Number (Target)`. This adds a second metric next to the primary value. **2. Set the target value** Set `device_id` as the target value with **count distinct** and no filters. This shows down devices relative to total devices. **3. Emphasize the comparison** Open the `Style` tab. In `Target Metric`, change the color of the concatenation symbol and the metric so the comparison stands out. See [Chart styling options](/products/building-bi/reference/chart-styling-options). Step 4 ### Add a bar chart by device type ![Bar chart titled Currently Down Devices by Device Type with counts by mechanical type](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-bar-chart.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c0e8df5eed6671448cb021d2407e7ec9) Build a [bar chart](/products/building-bi/reference/chart-types#bar) that shows down devices by device type. Use the same Last Value data source as the Number (Target) widget. **1. Add the bar chart** Drag a `Bar` chart onto the canvas. Select `Point Time Series Last Value Aggregated`. **2. Filter to down devices** Set the filter on `cur_status` to `in` and `down`. **3. Configure the Y-axis** Use **count distinct** of `device_id`. This total should match your Number (Target) primary value. **4. Configure the X-axis** Use the `Device Mechanical Type Name` column. This ontology field returns types such as HVAC, AHU, or Water Meter. **5. Rename the axes** In `Setup`, open the dropdown for each column and set a display name. This updates the axis title and tooltip. **6. Style the chart** Open the `Style` tab and make these changes: * In [`General`](/products/building-bi/reference/chart-styling-options#general), set the title to `Currently Down Devices by Device Type`. * On the [`X-Axis`](/products/building-bi/reference/chart-styling-options#x-axis-and-y-axis) tab, adjust margin, interval, and value rotation so labels do not overlap. * In [`Data Labels`](/products/building-bi/reference/chart-styling-options#data-labels), enable labels with the eye icon. Set placement to `Outside`. Step 5 ### Add a line chart over time ![Line chart titled Down Devices in Last 7 Days with hourly counts on the X-axis](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-line-chart.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=9c4b45d7ba8e6d862a8d3f4af92e64ab) Create a [line chart](/products/building-bi/reference/chart-types#line) that shows down device counts over the last seven days. **1. Add the line chart** Drag a `Line` chart onto the canvas. Select `Point Time Series Real Time`. **2. Limit the time range** Real Time includes every update, so start with a time filter. Set **Last time range** to **Last 7 Days**. **3. Set the X-axis** Put `date_time_local` on the X-axis. This is the localized time for the building. Change the granularity from `none` to **Date Hour** so each point is an hourly count. **4. Set the Y-axis** Use **count distinct** of `device_id`. **5. Style the chart** In [`Style` > `General`](/products/building-bi/reference/chart-styling-options#general), set the title to `Down Devices in Last 7 Days`. Rename the axes to `Down Devices` and `Date Hour` from `Setup` or the axis title fields in `Style`. Step 6 ### Add a pivot table with device links ![Pivot table expanding device types to show device names linked to KODE OS device pages](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-pivot-table.gif?s=8def9d15d3f87f3c6289e8938d4b97ee) Create a table that lists every down device by name and links to its device page. When the count is high, you can drill down without leaving the dashboard. Building BI offers three table types: Raw, Pivot, and Aggregated. For collapsible device counts, use a [Pivot table](/products/building-bi/reference/chart-types#table-pivot). See also [Table types](/products/building-bi/concepts/choosing-visualizations#table-types). **1. Add the pivot table** Drag a `Table Pivot` onto the canvas. Select `Point Time Series Last Value Aggregated`. **2. Filter to down devices** Filter on `cur_status` with `in` and `down`, as in the earlier widgets. **3. Build the hierarchy** Pivot charts have Hierarchies, Pivoted Columns, Values, and Adjunct Metrics. For this dashboard, use only **Hierarchy** and **Adjunct Metrics**. In **Hierarchy**, add `Device Mechanical Type Name`, then `device_name`. You could use `area_name` instead if you want to group by floor. **4. Add floor context** Add an adjunct metric for `area_name` so each row shows the floor name. **5. Rename columns and add URLs** In `Style`, rename the hierarchy columns to `Device Type` and `Device Name`. Open the `Device Name` tab. In the **URLs** section, enable URLs and apply `Device URL`. Each device name becomes a link to its device page. See [Table widget sections](/products/building-bi/reference/chart-styling-options#table-widget-sections). Step 7 ### Add a title and finish the layout ![Completed Down Devices dashboard with a title, Number (Target), bar chart, line chart, and pivot table](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-final-layout.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0d9f62282095323088f399399caaeaff) Add a [Text](/products/building-bi/reference/chart-types#text) widget for the dashboard title, then arrange the canvas. **1. Add a title** Add a text widget. Type `Down Devices`, set the text to title size, and place it in the top center of the dashboard. **2. Style the text** You can edit text styling in two places: the `Style` tab in chart configuration, or by selecting the text inside the widget. Selecting the text opens an inline editor for font size, weight, and alignment. For more styling options across widgets, see [Widget customization](/products/building-bi/widget-customization). ![Text widget on the canvas with selected Down Devices text and the inline formatting toolbar](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-tutorial-text-widget-editor.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=7812a917fa57dea5ddc9c32df6794ab4) Inline text editor when you select text in the widget **3. Arrange the widgets** Drag and resize widgets until the layout matches the completed dashboard above. ## What you built You created a building-level Down Devices dashboard with a Number (Target) widget, a bar chart by device type, a seven-day line chart, and a pivot table with links to each device. ## Related reading > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Match chart types to the question you need to answer. > [card] [How filtering works](/products/building-bi/concepts/how-filtering-works) > > Learn how filters interact across widgets and pages. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup requirements for every widget type. > [card] [Filter options](/products/building-bi/reference/filter-options) > > Review operators, scopes, and filter configuration fields. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Learn dashboard editing, filters, and collaboration workflows. > [card] [Widget customization](/products/building-bi/widget-customization) > > Style widgets, apply defaults, manage palettes, and go deeper on layout. > [card] [Data sources](/products/building-bi/data-sources) > > Connect dashboards to live building data from Cloud BMS. # Widget customization and styling Source: https://docs.kodelabs.com/products/building-bi/widget-customization Customize widget styles, apply bulk styling, use color palettes, copy and paste styles, and add enhanced graphic views to Building BI dashboards. Building BI lets you customize how widgets look across your dashboards. You can style individual widgets, apply styles in bulk, copy styles between widgets, manage color palettes, and add enhanced graphic views. > [!NOTE] > > For per-chart [Style tab options](/products/building-bi/reference/chart-styling-options), [color tools](/products/building-bi/reference/color-tools), and [keyboard shortcuts](/products/building-bi/reference/keyboard-shortcuts), use the reference pages. ## In this guide > [card] [Add and configure](#add-widgets-to-a-dashboard) > > Place widgets and use Setup and Style panels. > [card] [Style and defaults](#style-tab-overview) > > Style overview, defaults, bulk edit, and copy styles. > [card] [Colors and graphics](#enhanced-graphic-view) > > Manage enhanced graphic views and color palettes. > [card] [Advanced chart options](#mark-areas) > > Add mark areas, reference lines, zoom, and scroll. ## Configuration field tooltips Hover over fields in the widget **Setup** and **Style** panels, dashboard-level controls, filters, slicers, and time range settings to see short inline guidance. Tooltips appear on hover without extra icons and disappear when you move the pointer away. Use them to understand field names that are standardized across widget types. For example, **X-Axis** explains the field used for grouping or time series. > [!TIP] > > Field tooltips reduce training overhead when you configure unfamiliar chart types or share dashboards across teams. ## Add widgets to a dashboard To start building charts, select `Edit Dashboard` to enter edit mode. The dashboard opens with the `Chart List` panel displayed on the right side, showing all available widget types. Use the search bar at the top of the panel to filter the list. **1. Choose a chart type** Drag a chart type from the `Chart List` and drop it onto the dashboard canvas. The `Chart Configuration` panel opens with `Setup` and `Style` tabs. Adjust the widget size by dragging its corners. ![Dashboard in edit mode showing a heatmap on Floor 1 and Floor 2, an empty widget with a Start building your widget message, and the Chart Configuration panel with Setup and Style tabs, chart type icons in a grid, and empty X-Axis, Y-Axis Dimension, Value, and Filters drop zones highlighted in red with Drag or add here placeholders](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-chart-config-empty.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=08afb7bbe8b576296c00d2cbe7a74d43) Dashboard in edit mode with an empty widget and the Chart Configuration panel showing chart type icons and empty axis fields **2. Select a data source** Choose a data source from the `Data Source` dropdown on the right side of the configuration panel. The available fields from that data source appear below, split into two expandable lists: * **Metrics** -- pre-aggregated values such as averages, sums, or counts. Select the `fx` button next to a metric name to view its underlying formula. * **Columns** -- fields pulled directly from the data source. Calculated columns also display the `fx` indicator. Each field displays an icon indicating its data type: `#` for numbers, `A` for strings, a calendar icon for date/time, and a switch icon for booleans. Use the search bar to find specific fields. Select the `+` button next to `Metrics` or `Columns` to create a new calculated column, metric, or URL directly from the chart configuration panel. ![Data source panel showing Data Source dropdown set to Point Time Series R, a search bar, and expandable Metrics and Columns sections each with a plus button and chevron to expand or collapse](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-data-source-panel.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=7e440decd885ec97b200450f84673572) Data source panel showing the Data Source dropdown, search bar, and expandable Metrics and Columns lists ![Create Metric dialog showing Calculated, Metric selected, and URL radio buttons, Name and Display Name fields, a Description field, Data Type dropdown set to INT\_VALUE, an SQL Expression code editor, and Cancel and Create buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-create-metric.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=f4a507d7f1b27a3cbe3062f5cfba2898) Create Metric dialog with Calculated, Metric, and URL tabs, name, description, data type, and SQL expression fields The `Create Metric` dialog has three tabs: * **Calculated** -- creates a row-level calculated column with an SQL expression. * **Metric** -- creates an aggregate metric that recalculates based on chart grouping. * **URL** -- creates an internal or external link column. Enter a `Name`, `Display Name`, optional `Description`, select the `Data Type`, and write the `SQL Expression`. Select `Create` to add it to the data source. See [Data sources](/products/building-bi/data-sources) for detailed guidance on writing calculated columns and metrics. > [!WARNING] > > Calculated columns, metrics, and URLs created here are added to the data source itself, not just the current chart. Any changes affect all dashboards that use this data source. **3. Map data to chart fields** Drag and drop columns and metrics from the data source list into the `X-Axis`, `Y-Axis`, `Value`, `Filters`, and `Top N Filter` fields to define what the chart displays. Select the arrow (`>`) next to any field to configure display name, aggregate function, and sort order. ![Dashboard in edit mode showing an Average Floor Zone Air Temperature heatmap with a color gradient from 68 to 74 degrees, and the Chart Configuration panel with X-Axis set to Date Time Local, Y-Axis Dimension set to Area Name, Value set to Number Value, Filters showing Ontology Point Field, Date Time Local, and Number Value, Top N Filter section, and a Metrics list including Total Count, Delta Value, Zone Air Temperature, Net Occupancy, and Average](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-chart-config-populated.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=9593460dfca982ff4bda4efbc82f653d) A configured heatmap widget with data source, axis fields, and filters populated ### Chart types Building BI includes charts, tables, KPI cards, and specialized widgets. For Setup fields and use cases per type, see [Chart types](/products/building-bi/reference/chart-types). For guidance on which visual to pick, see [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations). | Category | Chart types | | - | - | | Bar | [Bar](/products/building-bi/reference/chart-types#bar), [Horizontal Bar](/products/building-bi/reference/chart-types#horizontal-bar), [Stacked Bar](/products/building-bi/reference/chart-types#stacked-bar), [Horizontal Stacked Bar](/products/building-bi/reference/chart-types#horizontal-stacked-bar) | | Line | [Line](/products/building-bi/reference/chart-types#line), [Line Area](/products/building-bi/reference/chart-types#line-area), [Stacked Line](/products/building-bi/reference/chart-types#stacked-line), [Time Series](/products/building-bi/reference/chart-types#time-series) | | Combo and scatter | [Combo](/products/building-bi/reference/chart-types#combo), [Scatter](/products/building-bi/reference/chart-types#scatter), [Advanced Scatter](/products/building-bi/reference/chart-types#advanced-scatter) | | Distribution | [Pie](/products/building-bi/reference/chart-types#pie), [Sunburst](/products/building-bi/reference/chart-types#sunburst), [Polar Bar](/products/building-bi/reference/chart-types#polar-bar), [Stacked Polar Bar](/products/building-bi/reference/chart-types#stacked-polar-bar), [Treemap](/products/building-bi/reference/chart-types#treemap) | | Statistical | [Heatmap](/products/building-bi/reference/chart-types#heatmap), [Boxplot](/products/building-bi/reference/chart-types#boxplot), [Horizontal Boxplot](/products/building-bi/reference/chart-types#horizontal-boxplot), [Sankey](/products/building-bi/reference/chart-types#sankey) | | Number and KPI | [Card](/products/building-bi/reference/chart-types#card), [Multi-row Card](/products/building-bi/reference/chart-types#multi-row-card), [Number (Period)](/products/building-bi/reference/chart-types#number-period), [Number (Target)](/products/building-bi/reference/chart-types#number-target), [Number with Trend-line](/products/building-bi/reference/chart-types#number-with-trend-line), [Gauge](/products/building-bi/reference/chart-types#gauge) | | Tables | [Table Raw](/products/building-bi/reference/chart-types#table-raw), [Table Pivot](/products/building-bi/reference/chart-types#table-pivot), [Table Aggregated](/products/building-bi/reference/chart-types#table-aggregated) | | Specialized | [Text](/products/building-bi/reference/chart-types#text), [iFrame](/products/building-bi/reference/chart-types#iframe), [Weather](/products/building-bi/reference/chart-types#weather), [Slicer](/products/building-bi/reference/chart-types#slicer), [Navigation](/products/building-bi/reference/chart-types#navigation), [Graphics](/products/building-bi/reference/chart-types#graphics), [Timeline](/products/building-bi/reference/chart-types#timeline), [Tree](/products/building-bi/reference/chart-types#tree), [Picture](/products/building-bi/reference/chart-types#picture), [Building Date Time](/products/building-bi/reference/chart-types#building-date-time) | ### Setup tab reference The `Setup` tab controls which data the widget displays and how it is structured. The fields available depend on the chart type. A heatmap exposes `X-Axis`, `Y-Axis Dimension`, and `Value` fields, while a bar chart uses `X-Axis`, `Y-Axis`, and `Legend` instead. Drag columns and metrics from the data source list into these fields to configure your widget. For the full field catalog, see [Chart setup parameters](/products/building-bi/reference/chart-setup-parameters). For per-type Setup requirements, see [Chart types](/products/building-bi/reference/chart-types). **Charts** `Field` A grid of chart type icons at the top of the `Setup` tab. Select any icon to switch the widget to a different chart type without removing it from the canvas. The axis and data fields update to match the new chart type. **X-Axis** `Field` The primary horizontal dimension for your data. Typically set to a time field (such as `Date Time Local`) for trend charts or a category field (such as `Area Name`) for comparison charts. Select the arrow (`>`) next to the field to configure the display name, aggregate function, and sort direction. **Y-Axis / Y-Axis Dimension** `Field` The vertical dimension for your data. Depending on the chart type, this may accept a metric for value-based charts or a category column for dimension-based charts like heatmaps. **Legend (Breakdown)** `Field` Splits data into categories within the chart. For example, set `Legend` to `Area Name` to break down total energy usage by individual floors. Available on bar, line, combo, and similar multi-series chart types. **Value** `Field` The numeric measure the chart displays. Used on chart types like heatmaps and treemap charts where the value is mapped to color intensity or size rather than an axis position. **Filters** `Field` Restricts the data shown in the widget. Add one or more columns and configure filter criteria for each. Select the arrow (`>`) next to a filter to define the condition. Filter options vary by data type: date fields offer range pickers, string fields offer value lists, and numeric fields offer comparison operators. **Top N Filter** `Field` Limits the chart to the highest or lowest N values. Set the `Category` column, choose `Top` or `Bottom` from the dropdown, enter the number of items, and set the `Top N by Value` column to rank by. **Sort Order** `Field` Controls how data is ordered in the chart. Select the double-arrow icon (`⇅`) next to any column to change its sort direction. Drag columns within the `Sort Order` section to set priority when sorting by multiple fields. You can also add new columns for sorting directly in this section. **Data Refresh Interval** `Field` Controls how often the widget queries new data. Set shorter intervals (every minute) for live operational data, or longer intervals (hourly or daily) for historical trends. Choose the longest acceptable interval to optimize dashboard loading times. ## Style tab overview The `Style` tab controls how a widget looks. It does not change the underlying data or Setup mappings. Available sections depend on the chart type. Toggle a section on or off with the eye icon next to its name. At the top of the tab you can: * Select `Set as Default Style` to save styling from this widget as the page default. * Select `Apply Default Style` to apply the saved page default to this widget. * Toggle `Draggable` to allow or block repositioning on the canvas. * Toggle `Resizable` to allow or block resizing by dragging corners. For field-level Style options by section and chart type, see [Chart styling options](/products/building-bi/reference/chart-styling-options). > [!TIP] > > Select and edit multiple widgets at once by holding Shift and clicking them on the dashboard canvas, then apply style changes in bulk. ## Default styles Default styles let you save styling from one widget and apply it to other widgets on the same page. Application is manual: editing the default does not rewrite existing widgets until you select `Apply Default Style`. (Older Global Styles inherited automatically; Default Styles are a stamp you re-apply on purpose.) Each page maintains its own default style — this setting does not carry across pages or dashboards. > [!NOTE] > > Default styles apply at the page level, not the dashboard level. Each page has its own independent default style. ### Set a default style **1. Open the style tab** Enter edit mode on your dashboard and select the widget you want to use as your style source. Open the `Style` tab in the widget configuration panel. **2. Configure your styles** Adjust the style properties you want to save as the default. This can include background colors, borders, title formatting, margins, and chart-specific settings. **3. Save the default style** Select `Set as Default Style` at the top of the `Style` tab. Building BI saves the current widget style as the page default. ![Chart Configuration Style tab showing the Set as Default Style button highlighted, with style sections including General, Donut, Data Labels, Legends, Chart Tooltips, and Colors listed below](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-default-style-set.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=4148212398a208401fb7b5a5be4adca7) Style tab with Set as Default Style button highlighted at the top of the panel ### Apply a default style **1. Select the target widget** Select the widget you want to update. Open the `Style` tab in the widget configuration panel. **2. Apply the style** Select `Apply Default Style`. The widget adopts the saved default style for that page. ![Chart Configuration Style tab showing the Apply Default Style button highlighted, with bar chart style sections including General, X-Axis, Y-Axis, Bar Configuration, Data Labels, Legends, Chart Tooltips, Colors, Mark Area, Reference Lines, Zoom, Scroll, and Margins](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-default-style-apply.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=7be0f55c0d6273b9d4d63d31171591da) Style tab with Apply Default Style button highlighted on a different widget ### Apply a default style to multiple widgets **1. Open the selection menu** Open the three-dot menu on any widget and choose `Select All Widgets on Page` or `Select All [Chart Type] Widgets on Page`. **2. Apply the style** Select `Apply Default Style` from the action bar. All selected widgets update to match the page default. > [!TIP] > > After publishing your dashboard, you can reset the default style to start fresh on any page. ## Bulk styling Bulk styling lets you apply style changes to multiple widgets at once. The available style options depend on whether you select widgets of the same chart type or a mix of different types. ### Widget three-dot menu The three-dot menu on each widget provides the following actions: | Action | Description | | - | - | | `Duplicate` | Creates a copy of the widget on the same page | | `Copy to` | Copies the widget to another page within the dashboard or to a different dashboard | | `Copy Style` | Copies the style settings from the widget to the clipboard | | `Paste Style` | Applies a previously copied style to this widget | | `Save as Template` | Saves the widget as a reusable chart template | | `View as table` | Opens the chart’s categories, series, and values in a semantic table (supported chart types only). See [View chart data as a table](/products/building-bi/reference/accessibility/view-chart-as-table). | | `Select All` | Opens a nested menu with `[Chart Type] Charts on Page` and `All Charts on Page` | | `Delete` | Removes the widget from the dashboard | ![Widget three-dot menu showing Duplicate, Copy to, Save as Template, Select All with nested menu options Horizontal Stack Bar Charts on Page and All Charts on Page, and Delete](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-widget-three-dot-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=d0a069fcb879fe9a311ba4eb3a2ce912) Widget three-dot menu with Select All nested menu showing chart-type-specific and all-charts selection options ### Select widgets for bulk editing Open the three-dot menu on any widget and choose `Select All`. The nested menu offers two options: * `[Chart Type] Charts on Page` -- selects only widgets that match the current chart type (for example, `Horizontal Stack Bar Charts on Page`). * `All Charts on Page` -- selects every widget on the current page. You can also use keyboard shortcuts to select widgets: * Press Ctrl + A to select all widgets on the page. * Hold Ctrl and click individual widgets to build a custom selection. ### Same chart type selected When all selected widgets share the same chart type, the `Multiple Configurations` panel appears with both general and chart-specific style sections: * **General styles** -- `Paddings`, background, title, and default style buttons. * **Chart-specific styles** -- axis labels, bar configuration, data labels, legends, chart tooltips, colors, zoom, scroll, and margins. ![Multiple Configurations panel with Style tab showing General, Y-Axis, X-Axis, Bar Configuration, Data Labels, Legends, Chart Tooltips, Zoom, Scroll, and Margins sections when multiple bar chart widgets are selected](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-bulk-style-same-type.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=50a63bf1eff212fdfcfe4c01a0d25201) Multiple Configurations panel showing all style sections available when same-type widgets are selected ### Mixed chart types selected When your selection includes different chart types, the `Multiple Configurations` panel shows only the `General` section. Chart-specific sections are hidden because they do not apply to all selected widget types. Available settings in this mode: * `Paddings` * Background color * Title formatting * Default style buttons ![Multiple Configurations panel with Style tab showing only the General section when a donut chart and bar charts are selected together, with padding, background, and title settings visible](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/building-bi/bbi-bulk-style-mixed-type.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=08aa1e24f5646d0f77af19a98f4639de) Multiple Configurations panel showing only the General section when mixed chart types are selected ## Remove and duplicate in bulk You can remove or duplicate multiple widgets at once using bulk selection. **1. Select widgets** Use the three-dot menu to select widgets, or press Ctrl + A to select all widgets on the page. Hold Ctrl and click to add or remove individual widgets from your selection. **2. Choose an action** Select `Duplicate` or `Delete` from the action bar to apply the operation to all selected widgets. > [!WARNING] > > Deleting widgets in bulk cannot be undone. Verify your selection before confirming the deletion. ## Copy and paste styles Copy and paste lets you transfer visual styling from one widget to another without setting a page-level default. Use it to style multiple similar charts quickly or reuse fonts and layout settings across widget types. > [!NOTE] > > **Copy Style** copies visual settings only. It does not copy data queries, data source mappings, or widget-specific data configuration. ### Compatibility behavior | Target widget | What paste applies | | - | - | | **Same chart type** | Full style configuration (axes, colors, legends, labels, and layout) | | **Different chart type** | General visual styles only (fonts, padding, background, and compatible layout settings) | ### Copy and paste within a dashboard **1. Enter edit mode** Open your dashboard in edit mode. **2. Copy the source style** Select the widget whose style you want to copy. Open the three-dot menu and select `Copy Style`. ![Widget three-dot menu showing Duplicate, Copy to, Copy Style highlighted, Paste Style, Save as Template, Select All, and Delete options on a horizontal bar chart](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-copy-style-menu.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=8a1eddf3e0f430a86e7f7f72fc31cd74) Three-dot menu with Copy Style highlighted on the source widget **3. Paste the style** Select the target widget. Open the three-dot menu and select `Paste Style`. The target widget adopts the copied styling. ![Widget three-dot menu showing Paste Style highlighted on a different horizontal bar chart, ready to apply the previously copied style](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-paste-style-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=5b05517f9e0fd3794c3ba49a429ce437) Three-dot menu with Paste Style highlighted on the target widget To paste a style to multiple widgets at once, hold Ctrl and click each target widget, or use `Select All` from the three-dot menu. Then open the three-dot menu on any selected widget and select `Paste styles on selected`. The `Multiple Configurations` panel appears, and all selected widgets adopt the copied styling. ![Dashboard with multiple widgets selected showing the three-dot menu with Duplicate, Paste styles on selected, and Delete options, and the Multiple Configurations panel on the right](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-paste-styles-selected.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=df4038d32f0a1b6bd49fcceed24e741b) Multiple widgets selected with Paste styles on selected option in the three-dot menu ### Copy and paste across pages and dashboards You can copy a style on one dashboard page and paste it on another page or dashboard. Data bindings stay on each target widget; only compatible visual properties transfer. ## Keyboard shortcuts For the full shortcut list, see [Keyboard shortcuts](/products/building-bi/reference/keyboard-shortcuts). Common selection shortcuts while editing: | Shortcut | Action | | - | - | | Ctrl + A | Select all widgets on the current page | | Ctrl + click | Add or remove individual widgets from the selection | | Shift + click | Multi-select widgets on the dashboard canvas | ## Enhanced graphic view The enhanced graphic view embeds a floorplan **Graphics** widget in a Building BI dashboard. Graphic markers update automatically when users apply slicers, dashboard filters, page filters, or cross-filter selections from other widgets. Non-matching markers are hidden so the floorplan stays aligned with the active filter context. Graphics respond to BI filters without changing the underlying data query or widget data configuration — only marker visibility updates. ### Filter interactions | Filter source | Result | | - | - | | **Slicers** | Select a device, point, or ontology field; the graphic shows only matching markers | | **Dashboard or page filters** | Filter by fields such as point name; the graphic reflects the active filter scope | | **Cross-filtering** | Select a row in a table or another widget; the graphic updates to match the selection | Interaction is enabled automatically when a **Graphics** widget shares the dashboard with filter-enabled widgets. ### Build an enhanced graphic dashboard **1. Create a dashboard** Create a new dashboard or open an existing one in edit mode. **2. Add slicers** Add slicer widgets to the top of your dashboard for `Device Name`, `Point Name`, and `Ontology Point Field`. Each slicer provides a searchable dropdown where users can select one or more items to filter the entire page. **3. Add a data table** Add a table widget to display the filtered results. Configure it with columns such as `Area Name`, `Device Name`, and `Point Name` so users can review the raw data alongside the graphic. Users can cross-filter the graphic by selecting rows in the table. **4. Add a graphic widget** Add a `Graphics` widget to the dashboard canvas. Select the floor from the floor dropdown to display the corresponding floorplan. Ensure devices are added to the area and points are assigned on the graphic. **5. Configure graphic layers** The graphic displays data across multiple layers. Select a layer tab to switch between views: * **Temperature** -- shows temperature readings at sensor locations with color-coded markers (green for normal, red for alerts). * **Lighting** -- shows lighting status across zones. * **Air Quality** -- shows air quality readings at sensor locations. * **Occupancy** -- shows occupancy counts by zone. * **More** -- expands to show additional available layers. ![Enhanced graphic view dashboard showing Device Name, Point Name, and Ontology Point Field slicer filters at the top, a data table with Area Name, Device Name, and Point Name columns in the middle, and a floorplan graphic at the bottom with Temperature, Lighting, Air Quality, Occupancy, and More layer tabs and color-coded temperature markers](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-enhanced-graphic-view.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=a935b3d20a4bfe90c5c3a4fa318e5ca5) Enhanced graphic view dashboard with slicer filters, data table, and floorplan graphic showing temperature readings Slicer, filter, and cross-filter selections update both the data table and the graphic in real time. When you select a device from the `Device Name` slicer, the table and graphic show only data for that device. This creates an interactive drill-down view where users move from a floorplan overview to specific device context. ![Device Name slicer dropdown expanded showing a list of devices including FC\_15\_13, FC\_15\_12, FC\_15\_11, FC\_15\_10, FC\_15\_1, FC\_14\_EL, and others with checkboxes for multi-select filtering](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-enhanced-graphic-slicer.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=bb626e0f54d1c52eb1f1fe52abaa6560) Device Name slicer dropdown showing available devices for filtering > [!TIP] > > Collapse the left navigation panel using the `<` icon to give the graphic widget maximum screen space. This is especially useful on floorplan views where marker density is high. ![Enhanced graphic view with the left navigation panel collapsed, showing a large floorplan graphic with Temperature layer selected, color-coded markers showing green for normal temperatures and red for alerts across the floor layout](https://mintcdn.com/kodelabs/B4MTivRlYKOrn2ok/images/kode-os/building-bi/bbi-enhanced-graphic-floorplan.png?fit=max\&auto=format\&n=B4MTivRlYKOrn2ok\&q=85\&s=41fdc4d8626d330715a794e468126923) Enhanced graphic view with collapsed navigation panel, maximizing the floorplan display area ## Color palette management Building BI provides organization-level color palettes for consistent visual styling across dashboards and teams. Create palettes for branding, themes, or data visualization contexts in [Building BI settings](/products/building-bi/settings#custom-color-palettes), then apply them from widget style configuration. **1. Open color settings** Enter edit mode on your dashboard and select a widget. Navigate to `Chart Configuration` > `Style` tab > `Colors` section. **2. Choose a color type** Select a color type from the `Type` dropdown in the `Colors` section: * `Color Scheme` -- predefined sets of complementary colors designed by KODE Labs. Schemes are grouped into categories: `Bright`, `Cold`, `Default`, and `Pastel`. Select a category, then choose a specific scheme from the color swatches. * `Color Palette` -- custom sets of complementary colors created by your organization. Color palettes are managed in `Settings` and are available across all dashboards in your portfolio. * `Color Series` -- a sequential color series for ordered data. * `Range` -- a color range mapped to specific numeric value boundaries. * `Gradient` -- a smooth transition between two or more colors. The widget preview updates instantly when you select a new color option. ### Series colors Series colors let you assign specific colors to individual string or Boolean metrics. Keep colors standardized across dashboards for consistency (for example, green for normal operation and red for fault conditions). ### Gradients Gradients create a smooth color transition between two values. Select `Gradient` from the `Type` dropdown in the `Colors` section. Set the `Minimum` and `Maximum` values with their corresponding colors. Enable `Dynamic Gradient` to automatically adjust the range boundaries to the minimum and maximum values in your data. Toggle `Middle Color` on to add a third color at the midpoint of the gradient. The `Preview` bar shows the resulting color transition. ![Chart Configuration Style tab with Colors section expanded showing Type set to Gradient, Dynamic Gradient checkbox, Minimum set to 68 with blue color and Maximum set to 74 with red color, Middle Color toggle enabled, and Preview bar showing the blue-to-red gradient transition](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/building-bi/bbi-style-gradient.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=85319d374f61dacae42ad3ba96314b64) Gradient color configuration showing Type, Dynamic Gradient, Minimum and Maximum values, Middle Color, and Preview > [!NOTE] > > In charts such as heat maps, data label text color automatically switches between white and black based on the background gradient to maintain readable contrast. ### Range inclusion rules When you define a color range, the range excludes the `From Value` (left value) but includes the `To Value` (right value). For example, a range of 20 to 30 set to green means 30 displays as green, but 20 does not. ## Mark areas Mark areas highlight shaded background zones on a chart. Use them to visually denote acceptable operational ranges or fault threshold zones behind your plotted data. Mark areas can be generated dynamically based on column values or set to static boundaries. Additional styling options let you control the fill color, opacity, and label placement. For Style tab controls, see [Mark areas](/products/building-bi/reference/chart-styling-options#mark-areas). ## Reference lines Reference lines overlay static horizontal or vertical lines on a chart. Use them to mark setpoint temperatures, threshold limits, or target values so users can instantly assess whether data falls within expected boundaries. Reference lines can be generated dynamically based on column values or set to fixed positions. Additional styling options include line color, thickness, and label formatting. For Style tab controls, see [Reference lines](/products/building-bi/reference/chart-styling-options#reference-lines). > [!TIP] > > Use reference lines frequently on operational dashboards. They help users interpret data at a glance without needing to check separate documentation for acceptable ranges. ## Zoom and scroll Enable zoom and scroll for charts with long time-series data or large datasets. When enabled, users can zoom into specific time periods or scroll along the X-axis to navigate through data interactively. See [Top N vs scrolling](/products/building-bi/concepts/choosing-visualizations#top-n-vs-scrolling) to choose the appropriate approach. For Style tab controls, see [Zoom and scroll](/products/building-bi/reference/chart-styling-options#zoom-and-scroll). This option is particularly useful for dashboards displaying historical trends where users need to drill into specific periods. ## Styling best practices Follow these principles when styling widgets and dashboards: * **Clarity over complexity** -- if a chart is hard to read, it is not useful. Simplify the visualization before adding more styling. * **Use titles effectively** -- every widget title should answer two questions: what is this showing, and for what context? * **Avoid overcrowding** -- too many data labels make a chart unreadable, and too many colors make it confusing. Remove non-essential visual elements. * **Use reference lines** -- reference lines help users interpret data at a glance. Add them for setpoints, thresholds, or target values on operational dashboards. * **Keep consistency across dashboards** -- use the same colors, naming conventions, and layout patterns across all dashboards in a portfolio. ## Accessibility considerations When choosing colors for your charts and dashboards, consider two accessibility factors: * **Color blindness** -- Verify that your color choices are distinguishable for users with different types of color vision deficiency. * **Contrast** -- Confirm that text maintains sufficient contrast against its background color, particularly in data labels and legends. > [!NOTE] > > Use tools such as a contrast checker or color blindness simulator to validate that your color choices meet accessibility standards before publishing. ## Related reading > [card] [Choosing visualizations](/products/building-bi/concepts/choosing-visualizations) > > Match chart types to the question you need to answer. > [card] [Chart types](/products/building-bi/reference/chart-types) > > Look up Setup requirements for every widget type. > [card] [Chart styling options](/products/building-bi/reference/chart-styling-options) > > Look up Style tab options by chart type. > [card] [Color tools](/products/building-bi/reference/color-tools) > > Configure series colors, gradients, and palettes. ## Next steps > [card] [Dashboards](/products/building-bi/dashboards) > > Create and configure interactive dashboards with charts, tables, and widgets. > [card] [Data sources](/products/building-bi/data-sources) > > Connect dashboards to live building data from KODE OS modules and devices. # Baseline analysis configurations Source: https://docs.kodelabs.com/products/energ/analytics/baseline-portfolio-configurations Create and manage portfolio baseline configurations with weather normalization for energy, water, and waste Create and manage baseline (A fixed historical reference window you measure future usage against.) configurations that you apply on [Baseline analysis overview](/products/energ/analytics/baseline-portfolio-overview). Each configuration selects buildings, service types, baseline periods, and optional weather normalization (Adjusting usage comparisons for heating and cooling conditions with a regression model.). To learn how baselines and weather normalization work, see [Baselines and weather normalization](/products/energ/concepts/baselines-and-weather-normalization). ## Navigate to Configurations In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), expand `Baseline analysis` in the left sidebar and select `Configurations`. ![Configurations page showing breadcrumb Baseline Configuration greater than Configurations, status banner with collected and not collected building counts, Collect Historical Data button, and table with Name, Buildings Included, Buildings Succeeded, Weather Normalization, and Actions columns](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-configurations-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=03f34a6e17e6944575623dc25fe4e09d) Configurations list with collection status and baseline configuration table ## Review existing configurations The table lists every saved configuration. | Column | Description | | - | - | | **Name** | Configuration label. A `default` tag marks the portfolio default. | | **Buildings Included** | Buildings selected in the configuration | | **Buildings Succeeded** | Buildings with successfully trained models | | **Weather Normalization** | Whether weather normalization is enabled (`Yes` or `No`) | | **Actions** | Menu to edit, collect data, or delete | The status banner summarizes collection progress across the portfolio. Click **Collect Historical Data** when you need EnerG to refresh billing and interval history for buildings in the configuration. ## Create a configuration Click `+ Create Configuration` to open the three-step wizard. ### Step 1: Basic setup Enter a name and optional description. Mark **Default** when this configuration should load first on the Overview page. Select at least one service type in **Energy**, **Waste**, or **Water**. Expand each category to choose service types and set the **Baseline period** start and end months. ![Create configuration wizard step 1 Basic Setup with Name and Description fields, Default checkbox, Energy Waste and Water category dropdowns showing no selections, and Weather Normalization Enable toggle](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-create-basic.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=fa5d0ed0e10b31a56c27b80331111532) Create configuration Basic Setup step ![Basic Setup showing Energy with Electric tag, Waste with Composted Cardboard and Disposed Plastics tags, Water with Water tag, and January 2025 to April 2026 baseline period fields for each category](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-create-service-categories.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=5906792dbbba75d8212fb3f190289442) Service categories with selected types and baseline period #### Weather normalization Enable **Weather Normalization** to train regression models that adjust usage for heating and cooling conditions. ![Weather Normalization section with Enable toggle, Building Base Temperature options for Get from Building Information or Choose Base Temperature, Celsius and Fahrenheit unit radios, Cooling and Heating base temperature fields, Weather averages dropdown set to 10 years, and R-Squared Tolerance slider at 0.7](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-create-weather.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=2fc03417975c7ea0bad44a6ff97fe724) Weather normalization settings in Basic Setup Set the base temperature source, temperature unit, cooling and heating base temperatures, weather averages lookback, and R-squared tolerance. For each setting, see [weather normalization settings](/products/energ/reference/calculations-and-parameters#weather-normalization). Click `Next` when every required category has at least one service type selected. ### Step 2: Building assessment Select buildings to include. The table shows eligibility, weather period, and base temperatures. Expand a building to review service-level completeness, baseline dates, consumption, and cost. ![Create configuration step 2 Building Assessment with search and filter bar, building table showing Beacon Hill Complex expanded with service rows for waste energy and water including completeness percentages, and eligible buildings such as Capitol View Tower checked while Cochrane Supply is disqualified](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-create-assessment.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=a6f88ff67fe71738a0bacce086c9548e) Building Assessment step with eligible and disqualified buildings Buildings marked **disqualified** lack the data required for the selected service types. Repair meter gaps or widen the baseline period before you include them. Click `Next` to review the summary. ### Step 3: Summary and model training EnerG saves the configuration and trains weather normalization models for each building and service type. Training can take several minutes. The screen updates automatically when models finish. ![Create configuration step 3 Summary showing Saving configuration message, info banner that training can take a few minutes, and a loading spinner with Model training in progress text](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-create-saving.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=5bc4e32b47969bd8945455542f6a587c) Saving configuration with model training in progress > [!TIP] > > After training completes, open [Baseline analysis overview](/products/energ/analytics/baseline-portfolio-overview) and confirm buildings appear under **Configuration Results** with `Successful` status. ## Configure building baseline windows Portfolio configurations train weather-normalized models across many buildings. At each site, you also set **energy**, **water**, and **waste** baseline windows that drive targets, M\&V, and dashboard comparisons. Open the building view from [Portfolio Home](/products/energ/analytics/benchmarking), then use **Dashboards** > **Energy** > **Baseline Analysis** on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#baseline-analysis). Click **Edit Configuration** in the top-right corner of the baseline page to configure categories. ### Read baseline status The overview lists three service categories. | Category | What the overview shows | | - | - | | **Energy** | Whether a baseline is configured and which period applies to electric and fuel streams | | **Water** | Baseline status for water meters and billed usage | | **Waste** | Baseline status for waste reporting categories | Confirm each category is ready before you run targets, M\&V, or savings reports. ### Baseline length and purpose Pick a one-year or two-year baseline depending on data stability and reporting policy. For guidance on choosing a length, see [baseline length](/products/energ/concepts/baselines-and-weather-normalization#baseline-length). Close gaps in bills or interval feeds on [Building meters](/products/energ/buildings/meters) or through [Data completeness](/products/energ/data-quality/data-completeness) before you finalize a window. For qualification rules, see [baseline qualification](/products/energ/reference/calculations-and-parameters#baseline-qualification). > [!WARNING] > > Partial months or missing commodities inside the span disqualify that period until you repair the data. ![Baselines page with Energy, Water, and Waste sections each showing the auto-configure option selected, and an Edit Configuration button in the top-right corner](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-baseline-edit-config.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=c5e3ff82e03fbd6bae8819d73d476cb3) Baseline Configuration page for Energy, Water, and Waste ### Auto-configured baselines EnerG can pick the earliest 12-month span where every required service type has complete data. > [!NOTE] > > Use automatic configuration when utility coverage is complete and you need the earliest valid year. **1. Open edit mode** On the building baseline page, click **Edit Configuration**. **2. Choose automatic configuration** Select the auto-configure option that picks the earliest qualifying 12-month period. ![Baselines page in edit mode showing info banner about 12 or 24 month data requirements, with Enable EnerG to automatically configure your baseline selected for Energy, and Save Changes button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-baseline-auto-config.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=faa721559577522de8d9b92af0ae7b02) Edit mode with auto-configure selected for Energy **3. Review the proposed window** Confirm start and end months cover all energy, water, and waste feeds you expect. **4. Save the baseline** Click **Save Changes**, then confirm. Baselines feed metrics across EnerG, including the [Building Energy Baseline Analysis](/products/energ/analytics/building-dashboards-energy#baseline-analysis) report. ### Manual baseline selection Define the window when policy requires a specific end month or a two-year average. EnerG calculates the start month from your duration and ending month. **Ending month** `Month` Month that closes the baseline window when you configure a manual baseline. **1. Select duration** Choose a one-year or two-year baseline length. **2. Pick the ending month** Select the month that closes the baseline window. **3. Confirm the start month** Review the auto-calculated start month for the chosen duration. **4. Apply the baseline** Click **Save Changes** to store the manual baseline. **How two-year baselines average months** A 24-month baseline averages duplicate calendar months. Two January rows become one January value before comparisons run. ### Configure by service category Energy, water, and waste can each use a different baseline period. Electric and fuel streams roll into **Energy**. Water and waste stay separate. ![Baselines page in edit mode with Select a baseline chosen for Energy and Water showing Period One Year and dates January 2022 to December 2022 while Waste uses auto-configure](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-baseline-service-categories.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=74ac065f41aa2630afe87d56e59c5604) Manual baseline selection by service category > [!NOTE] > > Align baseline windows with the meters that existed for each category during the same months. ## Next steps > [card] [Baseline analysis overview](/products/energ/analytics/baseline-portfolio-overview) > > Compare portfolio usage on the Analysis and Configuration Results tabs. > [card] [Building information](/products/energ/buildings/building-information) > > Review base temperatures and area data that feed weather normalization. > [card] [Portfolio meters](/products/energ/analytics/portfolio-meters) > > Improve completeness before you rerun Collect Historical Data. > [card] [Building Energy — Baseline Analysis](/products/energ/analytics/building-dashboards-energy#baseline-analysis) > > Review baseline charts after you save building windows. > [card] [Energy modeling overview](/products/energ/concepts/energy-modeling) > > Use trained baselines in M\&V and forecasting workflows at the building level. # Baseline analysis overview Source: https://docs.kodelabs.com/products/energ/analytics/baseline-portfolio-overview Compare portfolio-wide usage and savings to baseline configurations with weather-normalized models Compare usage and savings across your portfolio against a saved baseline (A fixed historical reference window you measure future usage against.) configuration. Use the **Baseline Overview** page after you define configurations on the [Configurations](/products/energ/analytics/baseline-portfolio-configurations) page. To learn how baselines and weather normalization work, see [Baselines and weather normalization](/products/energ/concepts/baselines-and-weather-normalization). At each building, set energy, water, and waste baseline windows on [Configure building baseline windows](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows). Open **Baseline Analysis** on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#baseline-analysis) to review charts for one site. ## Navigate to Baseline Overview In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), expand `Baseline analysis` in the left sidebar and select `Overview`. ![Baseline Overview page on the Analysis tab showing date range, Energy resource type, Service type, and 2024 Baseline WN configuration filters, four summary cards for Baseline Usage, Actual Usage, Weather Normalized Usage, and Expected Usage, and a table with Building links and usage columns](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-overview-analysis.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=4912d6ed48f84dd308ffc3bdd9d1366b) Baseline Overview Analysis tab with summary cards and building comparison table ## Choose filters Use the filter row to scope the comparison. | Filter | Purpose | | - | - | | **Date range** | Reporting window for actual and normalized usage | | **Resource type** | Commodity group: `Energy`, `Water`, or `Waste` | | **Service type** | Narrow within the resource type (for example, `Electric`, `Natural Gas`, or `Lighting`) | | **Baseline configuration** | Saved portfolio configuration such as `2024 Baseline - WN`, `2024 WN Test`, or `Default Baseline` | When **Resource type** is `Energy`, **Service type** lists commodities such as `District Steam`, `Electric`, `Electric on Site Solar`, `Lighting`, `Natural Gas`, and `Steam`. Options change when you switch to `Water` or `Waste`. ## Analysis tab The **Analysis** tab summarizes portfolio totals and lists each building in a sortable table. ### Summary cards Four cards roll up usage for the selected filters: **Baseline Usage**, **Actual Usage**, **Weather Normalized Usage**, and **Expected Usage**. For what each figure means, see [how normalized comparisons read](/products/energ/concepts/baselines-and-weather-normalization#how-normalized-comparisons-read). ### Building comparison table The table lists one row per building. Click a **Building** name to open [Building information](/products/energ/buildings/building-information) for that site. Columns cover the four usage figures, gross floor area (`GFA`), normalized energy use intensity (`NEUI`), and actual versus normal heating and cooling degree days (Degree days measure how far outdoor temperature departs from a base temperature each day.). Use **Search** and **Filter** above the table to narrow the list. Click **Export data** to download the current view. ![Search field and Filter button with Building, Building Type, Country, State, and Region dropdown filters above the baseline building table](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-overview-filters.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=0f7a32e55cb7194d3fa7977c655e0329) Search and geographic filters above the building table ## Configuration Results tab Switch to **Configuration Results** to review model training status and regression detail by building. ![Baseline Overview on Configuration Results tab showing Buildings with Normalized Models, Buildings with Missing Data, and Buildings with Low Correlation summary cards, search and filter bar, and Beacon Hill Complex expanded with Electric and Natural Gas rows showing Successful status, R Squared values, and equations](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-baseline-overview-results.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=ae0385f7cdc1d35ec2bd3405ccc5c78f) Configuration Results tab with model status summary and expandable building rows ### Summary cards | Card | What it shows | | - | - | | **Buildings with Normalized Models** | Count of buildings with trained models versus buildings in the configuration | | **Buildings with Missing Data** | Buildings that lack required inputs | | **Buildings with Low Correlation** | Buildings where model correlation falls below tolerance | ### Building detail rows Expand a building row to see consumption, cost, weather period, and base temperatures. The service-level table shows model type, variables, `R Squared`, and the regression equation for each service type, plus a note when training needs review. For model fit thresholds, see [model accuracy thresholds](/products/energ/reference/calculations-and-parameters#model-accuracy). ## Next steps > [card] [Configurations](/products/energ/analytics/baseline-portfolio-configurations) > > Create or edit portfolio baseline configurations and train weather models. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Return to portfolio rankings before you drill into baseline results. > [card] [Portfolio meters](/products/energ/analytics/portfolio-meters) > > Confirm meter completeness before you collect historical data for baselines. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Link reduction targets to the configurations you select on Overview. # Portfolio Home Source: https://docs.kodelabs.com/products/energ/analytics/benchmarking Compare building performance across your portfolio using EUI, WUI, and GHG metrics on the EnerG Home page Rank and compare buildings across your portfolio by EUI (Energy Use Intensity: annual energy divided by conditioned floor area.), NEUI (Weather-normalized Energy Use Intensity: EUI adjusted for weather so sites are comparable across climates and years.), WUI (Water Use Intensity: water consumption normalized by floor area.), and GHG (Greenhouse gas emissions tied to area, occupancy, or revenue.). In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), open `Home` in the left sidebar to reach this page. Benchmarking normalizes usage by area so you can compare buildings of different sizes fairly. To learn how intensity metrics and percentile rankings work, see [Benchmarking and intensity](/products/energ/concepts/benchmarking-and-intensity). The workspace has three areas: an `All Sites` building list on the left, an interactive map in the center, and a `Building Rankings` chart on the right. ## Open Portfolio Home Click `Home` in the portfolio left sidebar. The page loads with EUI selected by default. ![EnerG Portfolio Home page with EUI toggle selected, Search Buildings field, All Sites list showing KODE 1420 Office and other buildings with kWh EUI cost and CO2e metrics, map with building pins, KPI cards for Avg EUI Data Completeness and Total Active Alerts, and Building Rankings bar chart with performance legend](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-portfolio-eui.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=c4d2e34a490262b9fdc0d936b380ed24) Portfolio Home with EUI selected, building list, map, KPI cards, and Building Rankings ## Select a metric lens Click `EUI`, `NEUI`, `WUI`, or `GHG` at the top to set which metric drives the building list, KPI cards, map pins, and rankings. For what each intensity metric measures, see [the three intensity lenses](/products/energ/concepts/benchmarking-and-intensity#the-three-intensity-lenses). When you select `NEUI`, building cards and rankings show weather-normalized intensity. Indicators show whether each site is weather-normalized or on default consumption. ![EnerG Portfolio Home with WUI toggle selected showing Avg WUI KPI card at 77.51 L per ft squared, building cards with water-related metrics, and Building Rankings updated for water intensity](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-portfolio-wui.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=6725cfbbe2a49d86a49ef3b6b73b180f) Portfolio Home with WUI selected and average WUI KPI card ![EnerG Portfolio Home with GHG toggle selected showing Avg GHG KPI card, building list with CO2e values, and Building Rankings colored by emissions performance](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-portfolio-ghg.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=6d6661fe3f3706d6d35c62c1b6e97da6) Portfolio Home with GHG selected and average GHG KPI card All three lenses share the same layout. Only the metric labels and ranking logic change. > [!TIP] > > Select `EUI` to compare buildings of different sizes on a per-square-foot basis rather than by total usage. EUI uses building area **over time**, so when area changes after renovations or a new measurement, historical EUI periods update to match the area in effect for that period. Review effective area context on [Building information](/products/energ/buildings/building-information#building-area-over-time) when a value looks unexpected. ## Set the time period Click the `Trailing 12 Month` dropdown to change the reporting window. ![Time period dropdown on Portfolio Home expanded to show Trailing 12 Month selected with checkmark and calendar years 2026 through 2021 listed below](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-time-period.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=e092b030619fd670131e957ce6c8a887) Time period dropdown with Trailing 12 Month and calendar year options * **Trailing 12 Month** — rolling 12-month trailing total (default) * **Calendar years** — fixed annual periods such as 2025 or 2024 The selected period applies to KPI cards, building cards, map markers, and rankings at the same time. ## Read summary KPI cards Three KPI cards appear above the map. Labels change with the active metric toggle. * **Average metric** — portfolio average for EUI, WUI, or GHG over the selected period * **Data Completeness** — percentage of expected billing data received across all buildings * **Total Active Alerts** — count of open data quality alerts portfolio-wide ## Browse building cards The `All Sites` list shows every building in the portfolio. Each card includes property type, area, name, address, and metric pills for the active lens. A collapsed card shows the primary metrics in the card body. Click `+ 1 more` to reveal additional metrics such as CO2e when EUI is active. ![Northgate Value Mart building card with four metric pills visible including kWh EUI cost and CO2e emissions without the plus 1 more link](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-building-card-expanded.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=63a9d7c1433940ff7125444a50f19f6a) Building card with all metric pills visible including CO2e For example, **KODE 1420 Office** at 1420 Washington Boulevard in Detroit, Michigan may display: * **184,623.99 kWh** — total energy for the period * **CO2e: 234,949.62** — emissions total * **Charges: \$853,478.09** — utility cost * **EUI: 6.30 kBtu/ft²** — energy use intensity Exact values depend on your data sources, completeness, and selected time period. Use the `Search Buildings...` field to find a site by name. Click any card to open its detail panel on the left. ## Star buildings and filter favorites Click the star icon on a building card to mark it as a favorite. Toggle `Starred Buildings` at the top of the list to show only starred sites. > [!TIP] > > Star buildings you review often so the favorites filter shortens repeat benchmarking sessions. ## Sort the building list Click the sort icon (two arrows) next to the search field. ![Sort dropdown on Portfolio Home showing Sort order options Lowest to Highest and Highest to Lowest and Sort by options Building Name EUI Cost and Usage with Building Rankings visible behind](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-sort-menu.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=4ba13dd04a77e969a6e9de5281fdf5bf) Sort menu with order and sort-by options * **Sort order** — `Lowest to Highest` or `Highest to Lowest` * **Sort by** — `Building Name`, `EUI`, `Cost`, or `Usage` ## Filter the portfolio Click the filter icon (funnel) to narrow the building list, map, KPI cards, and rankings together. ![Filter modal on Portfolio Home with dropdowns for Building Type Countries States Brands and Regions and sliders for Building Area Size Building EUI and Carbon Emission Intensity ranges with Clear Filters and Apply buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-filter-modal.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=5c902ab997e60c67082dab8569ab6c5d) Filter modal with building type, geography, brand, and range sliders Filter by building type, country, state, brand, and region. Use range sliders for building area, EUI, and carbon emission intensity when you need tighter scope. > [!NOTE] > > Benchmarking scores only buildings that meet your [data completeness](/products/energ/concepts/data-completeness) threshold. Buildings below it appear with **No Ranking** until data improves. ## Configure detail panel sections Click the gear icon above the building list to open `Configure Sections`. Drag sections to reorder them. Use checkboxes to show or hide sections. Turn on `Keep Open` to leave accordions expanded for every building. ![Configure Sections dialog listing Building Information Target Performance Energy Modeling Performance Historical Performance Waste Performance and Alert Performance each with checkbox Keep Open toggle and drag handle plus Cancel and Save Changes buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-configure-sections.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=cbaaf28ff29a99e8f84973f970830e99) Configure Sections dialog with core performance sections > [!TIP] > > The `Keep Open` setting applies to all buildings in your account, not only the building you have selected. ## Open a building detail panel Click a building card to replace the list with a detail panel. You stay on Portfolio Home—you do not enter the building view until you click `Go to Building`. The panel shows summary metrics, map context, ranking widgets, and expandable sections so you can triage a site before you open building-level dashboards. ![KODE 1420 Office detail panel with Back to all Buildings link Go to Building button summary pills for kWh CO2e Charges and EUI, map with Building Rankings card showing EUI 1.84 kWh per ft squared Ranking 1 and Percentile 95.5 percent, and Building Performance bell curve](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-building-detail-panel.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=addc08d4098b5b07555a938787de81cf) KODE 1420 Office detail panel with ranking cards and performance chart Summary pills at the top mirror the building card. Click `Go to Building` to open the [building view](/products/energ/get-started/navigation#building-view). Click `Back to all Buildings` to return to the full list. ### Detail panel sections Expand each section to review building-specific data without leaving Portfolio Home. ![KODE 1420 Office detail panel listing expandable sections for Building Information Target Energy Modeling Performance Historical Performance and Waste Performance with icons and subtitles](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-building-detail-sections.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1d47f0038c5bc5f2827d78e5989c5fe3) KODE 1420 Office detail panel with expandable performance sections | Section | What it shows | | - | - | | **Building Information** | Building details and specifications | | **Target** | Energy performance targets for this building | | **Energy Modeling Performance** | Actual energy use versus modeled predictions | | **Historical Performance** | Historical energy performance data and trends | | **Waste Performance** | Building waste usage and reporting | | **Alert Performance** | Anomalies and issues in billing data | | **Certifications Performance** | Building certifications and compliance records | Scroll the panel to reach **Alert Performance** and **Certifications Performance** when those sections are enabled in `Configure Sections`. ## Use the Building Rankings widget The `Building Rankings` bar chart on the right ranks every building by the active metric and colors each bar by percentile band. For what each band color means, see [how rankings and percentiles work](/products/energ/concepts/benchmarking-and-intensity#how-rankings-and-percentiles-work). Click the expand icon in the top-right corner of the widget for a larger view with readable axes and labels. > [!NOTE] > > Use expanded chart mode when you present rankings to stakeholders who need larger labels. ## Next steps > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Review portfolio energy usage, cost, and emissions charts. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Analyze usage, cost, and emissions for a single building with shared date ranges. > [card] [Alert Center](/products/energ/data-quality/alert-center) > > Triage billing anomalies surfaced in Alert Performance and portfolio alerts. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Connect feeds that raise completeness so more buildings qualify for benchmarking. # Building Energy dashboard Source: https://docs.kodelabs.com/products/energ/analytics/building-dashboards-energy Review building-level energy usage, cost, targets, data quality, billing data tables, and M&V results on the Building Energy dashboard in EnerG The building **Energy** dashboard shows how one site performs on usage, cost, and baseline (A fixed historical reference window you measure current usage against.) comparisons. In the [building view](/products/energ/get-started/navigation#building-view), open `Dashboards` in the left sidebar, then select `Energy`. The page header reads **Energy** with the subtitle *Energy Use, Efficiency, and Performance Overview.* `Monthly Reports` opens by default. A secondary menu lists other report types such as `Annual Reports`, `Comparison`, and `Interval Trends`. See [Portfolio and building navigation](/products/energ/get-started/navigation#energy-dashboard-report-menu) for the full menu. ![Building Energy dashboard for Northgate Value Mart with Monthly Reports selected, Usage toggle active, date range 06/22/2025 to 05/22/2026, Usage Compared to Previous Year bar chart with current and prior year bars, and Difference percentage chart below](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-monthly-reports-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=5fd260a7f0ca7edc621deb5300c23457) Building Energy Monthly Reports with Usage selected and year-over-year comparison ## Energy report menu After you select `Energy` under `Dashboards`, use the secondary menu to switch report types. | Report | What it shows | | - | - | | `Monthly Reports` | Month-by-month usage or cost with year-over-year and baseline charts | | `Annual Reports` | Annual summaries by service type and meter | | `Comparison` | Side-by-side comparison of two time periods | | `Interval Trends` | Sub-daily charts and heat maps ([Interval Trends](#interval-trends)) | | `Energy Modeling` | Quick access to [M\&V](/products/energ/energy-modeling/mv-models) and [Forecast](/products/energ/energy-modeling/forecasting) | | `Target` | Reduction goals, baseline comparison, and variance charts ([Target](#target)) | | `Data Quality` | Completeness and billing gaps for this building | | `Data Table` | Raw billing data in a sortable table | | `Baseline Analysis` | Baseline KPIs and charts ([Baseline Analysis](#baseline-analysis)); configure windows on [Configurations](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) | > [!NOTE] > > Building Energy reports apply to the site you selected in the top bar. Portfolio rollups live on the [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy). ## Monthly Reports controls The control row at the top of **Monthly Reports** sets the metric lens and reporting window. | Control | Purpose | | - | - | | **Usage / Cost** | Switches every chart between consumption and billed cost (`Emission` appears when your deployment includes it) | | **Date range** | Select start and end months (for example, `06/22/2025 – 05/22/2026`) | All charts on the page refresh together when you change the toggle or date range. ## Usage lens Select **Usage** on the toggle to view consumption charts in kWh (or the unit configured for each service type). ### Usage Compared to Previous Year The top chart compares current-period usage to the same months in the prior year. * **Teal bars** — current reporting period * **Light gray bars** — previous year * **Striped bars** — accrued or estimated months without final bills The **Difference** chart below shows the percentage change between periods. Red values indicate increases; teal values indicate decreases. > [!WARNING] > > Treat striped bars as estimates until final bills post and replace accrued values. ### Usage per Service Type The **Usage per Service Type** chart groups consumption by utility category each month. ![Usage per Service Type chart with grouped bars by month from June 2025 to May 2026 showing Natural Gas in purple and Electric in yellow with striped bars for March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-usage-per-service-type.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=bf38ea3fab449b594f00dca2bcb7635e) Usage per Service Type grouped bar chart by month Legend colors map to categories such as **Natural Gas**, **Electric**, and **Lighting**. Use this chart to see seasonal fuel shifts, such as higher natural gas in winter months. ### Usage per Meter The **Usage per Meter** chart breaks monthly consumption down by individual meter or account. ![Usage per Meter chart with yellow orange and red grouped bars by month from June 2025 to March 2026 showing meter-level consumption peaks in winter months](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-usage-per-meter.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=0fb790c34a647f8819742f5dc326f8fb) Usage per Meter grouped bar chart by month Compare meter bars when you trace a spike to a specific account or equipment feed. Pair this view with [Building meters](/products/energ/buildings/meters) when you need meter configuration detail. ### Usage Compared to Baseline The **Usage Compared to Baseline** chart compares actual consumption to the baseline you configured for the building. ![Usage Compared to Baseline chart with Actual vs Baseline legend showing teal actual bars and light gray baseline bars by month from June 2025 to May 2026 with striped segments on March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-usage-compared-to-baseline.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=c2f9009098f6f78a136196716f940cce) Usage Compared to Baseline with Actual and Baseline bars by month * **Baseline** — light gray bars * **Actual** — dark teal bars * **Striped segments** — projected or incomplete actuals for the month Configure baselines from **Baseline Analysis** in the report menu. Use [Configure building baseline windows](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) for **Edit Configuration** steps. ## Cost lens Select **Cost** on the toggle to view billed charges in your configured currency. ### Cost Compared to Previous Year The layout matches the usage view. **Cost Compared to Previous Year** shows current and prior-year spend by month. The **Difference** chart below reports percentage change in cost. ![Building Energy dashboard with Cost selected showing Cost Compared to Previous Year bar chart with green current year and gray prior year bars and Difference percentage chart with red increases and teal decreases](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-cost-compared-to-previous-year.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=46829aabbfe5a1e757cd09fd6d0ff46a) Cost Compared to Previous Year with current and prior year bars and variance chart Green bars represent the current period. Gray bars represent the prior year. Striped bars indicate accrued or estimated cost for months without final bills. ### Cost per Service Type The **Cost per Service Type** chart groups spend by utility category. ![Cost per Service Type chart with purple Natural Gas and yellow Electric bars by month from June 2025 to March 2026 with striped March 2026 bars](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-cost-per-service-type.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b2918de524780384a63715589c139de7) Cost per Service Type grouped bar chart by month Electric cost typically dominates year-round. Natural gas cost rises in heating months. Use this chart to explain tariff or operations changes by fuel type. ### Cost per Meter The **Cost per Meter** chart shows monthly spend by meter or account. ![Cost per Meter chart with yellow and orange grouped bars by month from June 2025 to March 2026 and striped March 2026 bars](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-cost-per-meter.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=43b3690183c9f2af8e7f5edc27fe08a6) Cost per Meter grouped bar chart by month ### Cost Compared to Baseline The **Cost Compared to Baseline** chart compares actual spend to your configured cost baseline. ![Cost Compared to Baseline chart with Baseline gray bars and Actual teal bars by month from June 2025 to May 2026 with striped actual bar for March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-cost-compared-to-baseline.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3debd9e7dce0e11a8352c7b056a77831) Cost Compared to Baseline with Actual and Baseline bars by month > [!TIP] > > Keep one date range while you switch between **Usage** and **Cost** so month-to-month comparisons stay aligned across charts. ### Blended Rate The **Blended Rate** view shows utility rate trends by service type. Select **Electric**, **Natural Gas**, **District Steam**, or another configured service type to update the chart and table. ![Blended Rate dashboard for Electric with TTM blended rate 0.1817 dollars per kWh, prior month and year comparisons, monthly blended rate bars with TTM trend line from Aug 2025 to Jul 2026, and historical rates reference table](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-blended-rate.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=a33f95fd8778281cd11da7efa38ccbf4) Blended Rate view with TTM metrics and monthly rate chart | Element | What it shows | | - | - | | **TTM Blended Rate** | Trailing twelve-month blended rate for the selected service type | | **vs. Prior Month** / **vs. Same Month Last Year** | Period comparisons for the current TTM value | | **Monthly Blended Rate chart** | Calendar-month blended rate bars with a TTM trend line | | **Historical Rates Reference** | Month-by-month rates by year with average blended rate | Blended rate is total cost (supply, delivery, fees, taxes, and other pass-throughs) divided by total energy consumption for the same period. TTM blended rate uses the most recent twelve months. ## Annual Reports Select `Annual Reports` from the Energy secondary menu to compare years for the selected building. The page header and **Usage / Cost** toggle behave the same as Monthly Reports. The date control uses a **year range** (for example, `2021` to `2025`) instead of month-by-month selection. ### Usage lens With **Usage** selected, the main card is **Usage and Usage per Area**. It contains two bar charts that share the same year axis. ![Building Energy Annual Reports with Usage selected showing Usage per Area chart in kWh per ft squared and Usage Analysis chart in kWh by year from 2021 to 2025](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-annual-reports-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=ac126c57ae9b812729edfc212d771e28) Annual Reports Usage view with Usage per Area and Usage Analysis by year | Chart | What it shows | | - | - | | **Usage per Area** | Energy intensity in **kWh/ft²** by calendar year | | **Usage Analysis** | Total building consumption in **kWh** by calendar year | Scroll below the paired charts for additional annual usage views. #### Usage per Service Type and Usage per Meter ![Annual Usage per Service Type grouped bar chart by year 2021 to 2025 with Natural Gas Electric and Electric on Site Solar legend, and Usage per Meter grouped chart below with meter categories by year](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-annual-usage-breakdown.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=4c1ea7827553d52ada1dfd48f755dca4) Annual Usage per Service Type and Usage per Meter by year * **Usage per Service Type** — grouped bars by year for **Natural Gas**, **Electric**, **Electric on Site Solar**, and other configured categories * **Usage per Meter** — grouped bars by year for each meter or account tied to the building Use **Usage per Service Type** to see fuel mix shifts across years. Use **Usage per Meter** when you isolate one account or submeter. ### Cost lens Select **Cost** on the toggle to open **Cost and Cost per Area** with the same paired-bar layout. ![Building Energy Annual Reports with Cost selected showing Cost Analysis chart in US dollars and Cost per Area chart in dollars per ft squared by year from 2021 to 2025](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-energy-annual-reports-cost.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a32364d2f0744c299ec3bfed0a92eeae) Annual Reports Cost view with Cost Analysis and Cost per Area by year | Chart | What it shows | | - | - | | **Cost Analysis** | Total utility spend in your configured currency by calendar year | | **Cost per Area** | Cost intensity in **\$/ft²** by calendar year | #### Cost per Service Type The **Cost per Service Type** chart groups annual spend by utility category. ![Annual Cost per Service Type chart with Electric in yellow and Natural Gas in purple bars by year from 2021 to 2025](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-energy-annual-cost-per-service-type.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=60caf9ec600aa83b84578c0edc0b530d) Annual Cost per Service Type grouped bar chart by year Electric cost typically dominates each year. Natural gas adds a smaller fixed component in this view. Compare annual cost charts to [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) Annual Reports when you place one building in portfolio context. ## Comparison Select `Comparison` from the Energy secondary menu to align utility bill totals with interval meter readings for the same building. The page title reads **Comparison** with the subtitle *Utility vs Interval & Variance.* ### Controls | Control | Purpose | | - | - | | **Meter pair** | Select the utility meter and the interval meter to compare (for example, `Utility Meter to Shadow Meter`) | | **Date range** | Set the months included in both charts | ### Usage Comparison The top chart, **Usage Comparison**, plots monthly **Utility** and **Interval** consumption on one axis in kWh. * **Solid blue bars** — utility bill totals * **Blue striped bars** — utility totals marked as accrued when final bills are not yet posted * **Solid teal bars** — interval meter totals for the same months Compare bar heights month by month to see whether billed usage tracks sub-daily interval data. ### Variance % The **Variance %** chart below reports the percentage gap between utility and interval totals for each billing period. Red bars extend downward from the zero line when variance is large. Striped bars match accrued utility months in the chart above. ![Building Energy Comparison page for KODE 1420 Office with Utility Meter to Shadow Meter selected and February 2026 through May 2026 date range, Usage Comparison grouped bar chart with Utility and Interval bars in kWh, and Variance % chart with red bars by billing period](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-comparison.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=65a66b8b524c372956560014da2cda39) Comparison view with Usage Comparison and Variance % charts Use this view with [Meter comparisons](/products/energ/data-quality/meter-comparisons) when you need to validate billing against interval hardware. Open `Data Quality` first when alerts show missing bills for the selected period. ## Interval Trends Interval trends turn high-frequency meter reads into daily charts, overlays, and heat maps. Open this report from the Energy secondary menu when you need sub-daily patterns that monthly or annual charts cannot show. **1. Open Interval Trends** Expand **Dashboards**, select **Energy**, then click **Interval Trends** in the report menu. If only monthly totals exist, use **Monthly Reports** until interval feeds are available. **2. Confirm interval data** Interval trends require sub-daily data from [Arcadia](/products/energ/data-sources/arcadia) interval feeds or [KODE OS](/products/energ/data-sources/kode-os-data-source) meters. On [Building meters](/products/energ/buildings/meters), open a meter and confirm the **Interval Data** tab has reads. **3. Select meter and range** Pick the interval meter from the dropdown. Choose a span long enough to show weekly patterns. Two to four weeks works well for initial diagnostics. Enable temperature or degree-day (Degree days measure how far outdoor temperature departs from a base temperature each day.) overlays when you want to separate weather-driven load from operations. > [!NOTE] > > Buildings with only utility billing data do not populate these views. The default time range is often **Last 90 Days**. Change the span from the control in the page header. ### Daily Energy Usage The **Daily Energy Usage** card plots interval consumption as teal bars by day. An orange **Temperature** line uses the secondary axis in °F so you can relate load spikes to weather. ![Building Energy Interval Trends page with Last 90 Days selected showing Daily Energy Usage bar chart in kWh with teal daily bars and orange temperature line from February through May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-interval-trends-daily.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=0e8ca39a41a52181243a236a957f7354) Interval Trends Daily Energy Usage with temperature overlay Scroll the page for additional interval views on the same date range. ### Open vs closed hours **Daily Energy Usage: Open vs Closed Hours** splits each day into **Opened Hours** (blue) and **Closed Hours** (gray) so you can see how much load runs outside the building schedule. ![Daily Energy Usage Open vs Closed Hours grouped bar chart with blue Opened Hours and gray Closed Hours bars by day from February through May 2026 in kWh](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-interval-trends-open-closed-daily.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=2b1cafc2f69f96445affbd1fc06115b4) Daily interval usage grouped by opened and closed hours **Total Energy Usage: Open vs Closed Hours** summarizes the same split for the full selected period in a single chart. ![Total Energy Usage Open vs Closed Hours pie-style chart with Closed Hours segment in light blue for the selected reporting period](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-interval-trends-open-closed-total.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3bf21a8d50a9eaaced27d2c4c227510c) Total interval usage share for opened and closed hours Compare these charts to the operating schedule on [Building information](/products/energ/buildings/building-information) when after-hours load looks high. ### Hourly Energy Usage **Hourly Energy Usage** is a heat map with one row per day and columns for each hour of the day. Color intensity reflects kWh, from low usage in teal to high usage in red. A **Degree Days** chart on the right shares the same date axis. Red bars extend to the right for heating degree days; blue bars extend to the left for cooling degree days. Use it to separate weather-driven load from operational patterns. ![Hourly Energy Usage heat map with rows for each day and hourly columns from 12AM through 9PM showing teal to red intensity, color scale from 4.16 to 15.04 kWh, and Degree Days horizontal bar chart with red heating and blue cooling bars aligned by date](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-interval-trends-hourly.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=a2afded7b60dcce00055b055d937fb6f) Hourly usage heat map with degree-day correlation Use the heat map to: * Spot **after-hours usage** when bright cells appear during nights or weekends * Identify **holiday patterns** as cooler-colored rows * Compare **weekday versus weekend** profiles against your occupancy schedule > [!WARNING] > > Sparse interval gaps can distort heat maps. Fix data feeds on [Building meters](/products/energ/buildings/meters#interval-data-tab) before you act on a single bright cell. **When degree-day plots help most** Use degree-day plots after you confirm interval data quality so correlations reflect real usage rather than data gaps. ### Common diagnostic workflows | Task | Approach | | - | - | | Validate occupancy schedules | Compare weekday versus weekend hourly profiles with **Open vs closed hours** | | Investigate a spike | Narrow the date range to two weeks around the event | | Evaluate a retrofit | Compare two-week windows before and after the change date | | Detect equipment drift | Use a multi-month span and watch for gradual baseline shifts | > [!TIP] > > Read heat map colors against the legend scale so you compare relative intensity across cells, not absolute values. ## Energy Modeling Expand `Energy Modeling` in the Energy secondary menu to open **M\&V** or **Forecast** without leaving the dashboard. You need a trained M\&V model before results appear. See [Create an M\&V model](/products/energ/energy-modeling/mv-models) to configure baselines and training runs. ### M\&V Select `M&V` under `Energy Modeling` to review Measurement and Verification results for the building. The page keeps the **Energy** header and adds model-specific controls above the savings summary. #### Controls | Control | Purpose | | - | - | | **Model** | Select the baseline or retrofit configuration to analyze (for example, `2022 Baseline`) | | **Date range** | Set the months included in totals, charts, and the monthly table | | **View Summary** | Open a condensed summary of the selected model run | #### Savings summary and metrics The left column shows portfolio-style totals for the selected model and date range. * **Total Energy Savings** — net kWh difference between actual and adjusted baseline across the period. Red values mean actual use exceeded the baseline. * **Total Energy Savings Percentage** — percent change for the same window The **Metrics** table on the right breaks results down by service type such as **Electric** and **Natural Gas**. Each row compares **Actual**, **Adjusted Baseline**, **Savings**, and **% Savings**. Green values indicate savings; red values indicate over-consumption relative to the adjusted baseline. ![Building Energy M\&V page for Gateway Professional Center with 2022 Baseline selected and January 2022 through May 2026 date range, Total Energy Savings and Total Energy Savings Percentage in red, Metrics table with Actual Adjusted Baseline Savings and percent Savings rows for Electric and Natural Gas in kWh, and View Summary button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-mv-overview.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=7a51e4451a48df67b53b911bf1a5a00c) M\&V overview with savings totals and service-type metrics Scroll below the summary for charts and the monthly detail table. See [M\&V analysis](/products/energ/energy-modeling/mv-analysis) for accuracy metrics, failed runs, and multiple models per building. #### Consumption and savings charts Two stacked charts share the same month axis. **Consumption** plots **Actual** (teal) and **Adjusted Baseline** (gray) in kWh. Before the **Operation Date**, only actual bars appear. After that date, paired bars show how measured use compares to the weather- and operations-adjusted baseline each month. **Savings** reports the percent gap between actual and adjusted baseline. Teal bars above zero indicate months where actual use fell below baseline. Red bars below zero indicate months where actual use exceeded baseline. A vertical dashed **Operation Date** line marks when the measure or retrofit took effect. ![M\&V Consumption bar chart with Actual teal and Adjusted Baseline gray bars by month from January 2022 to March 2026 and vertical Operation Date line between January and March 2023, and Savings percent chart below with teal positive and red negative bars](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-mv-consumption-savings.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=bff5edca48bdcadf44a73f0eee8340f5) M\&V Consumption and Savings charts with Operation Date marker #### Monthly expected vs actual consumption The **Monthly Expected vs Actual Consumption** table lists each month in the selected range with sortable columns. | Column | What it shows | | - | - | | **Month** | Calendar month in the reporting window | | **Baseline** | Raw baseline value when configured for the row | | **Actual** | Measured consumption in kWh | | **Adjusted Baseline** | Model-adjusted expected use in kWh | | **Savings** | Difference between adjusted baseline and actual. Green when actual is below baseline; red when actual exceeds baseline | | **Savings Percentage** | Percent variance for the month | ![Monthly Expected vs Actual Consumption table with columns Month Baseline Actual Adjusted Baseline Savings and Savings Percentage showing January 2023 through April 2024 with green savings only in April 2023 and red negative savings in other months](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-mv-monthly-table.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=5df005340202a56807cc6ca0ee33619c) Monthly Expected vs Actual Consumption table with savings by month ### Forecast Select `Forecast` under `Energy Modeling` to project future consumption from a trained model. See [Forecasting](/products/energ/energy-modeling/forecasting) for setup and chart interpretation. ## Target Review how one building performs against active reduction targets. Create and edit goals on [Portfolio targets](/products/energ/analytics/portfolio-targets). EnerG applies assigned targets to this building when you open the report here. **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Target** Expand **Dashboards** in the left sidebar, select **Energy**, then choose **Target** from the Energy report menu. You can also reach target charts when you drill into a building from portfolio target dashboards. ### Controls | Control | Purpose | | - | - | | **Break down by service type** | Split charts by utility category when enabled | | **Target** | Select which reduction goal to display (for example, `2040 Reduction Goal`) | Charts use the unit configured for the target, such as **kBTU**. ### Charts Three charts stack on the Target page. | Chart | What it shows | | - | - | | **Target Energy Comparison** | **Actual** (solid teal), **Target** (dotted blue), and **Baseline** (solid black) trends over time, with savings versus target when the building is under target | | **Delta from Target** | Monthly gap between actual use and the target trajectory. Red bars mean actual exceeded the target; teal bars mean actual fell below the target | | **Delta from Baseline** | Monthly difference between actual use and the baseline period. Teal bars below zero indicate savings relative to baseline | ![Energy dashboard Target view with Breakdown by Service Type toggle Unit kBTU Target selector download control Target Energy Comparison chart showing Actual Target and Baseline Delta from Target bars and Delta from Baseline section](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-target-efficiency.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=431d4367821cce25107b221e711cb03e) Energy Use, Efficiency, and Performance Overview with target comparison and delta charts Red bars in **Delta from Target** often grow when the target line slopes down but actual use stays flat. Teal bars in **Delta from Baseline** show months where actual use stayed below the historical baseline. When **Break down by service type** is on, charts split by utility category so you can see which commodities drive variance from the target line. > [!TIP] > > Open [Portfolio Home](/products/energ/analytics/benchmarking) when you need building rankings and target progress together. Compare scenarios to goals on [Capital planning](/products/energ/sustainability/capital-planning#scenario-comparison). ## Data Quality Select `Data Quality` from the Energy secondary menu to review billing coverage for every meter assigned to the building. Use this view before you share monthly or target charts when gaps might skew the story. ### Controls | Control | Purpose | | - | - | | **Date range** | Limit the timeline and table rows to a start and end date (for example, `06/25/2025 – 05/25/2026`) | ### Bills Data Quality chart The **Bills Data Quality** chart is a horizontal timeline with one row per meter. Color segments classify each billing period by coverage. For what each legend color means, see [data quality legend](/products/energ/reference/data-and-meter-fields#data-quality-legend). Solid green bars across a meter row mean every month in range has complete coverage. ![Building Energy Data Quality page with date range 06/25/2025 to 05/25/2026, Bills Data Quality horizontal chart with Complete green bars for meters MTR-100856-PV01 MTR-100856-G01 and MTR-100856-E01, and detail table with Meter Number Type Service Type Usage and date columns](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-data-quality.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=5d658945c0d52390aa44bdf95978add7) Data Quality timeline and billing detail table ### Billing detail table The table below the chart lists individual billing records for meters in the selected period. Sort any column to find gaps or outliers. Columns include meter number, coverage type, provider, service type, account, deregulation status, usage, and billing dates. A **Complete** row with matching start and end dates confirms that period counts toward completeness scoring. See [Data completeness](/products/energ/data-quality/data-completeness) for how scores roll up to the building, and [Data quality overview](/products/energ/data-quality/data-quality-overview) for alerts and portfolio workflows. ## Data Table Select `Data Table` from the Energy secondary menu to audit line-level billing and calendarized records for the selected building. Use this view when you need to verify a specific meter, charge, or billing period behind a chart. ### Controls | Control | Purpose | | - | - | | **Period Type** | Control how periods are grouped in the grid | | **Service tags** | Filter by category with active chips such as `Delivery` or `Full Service` | | **Date range** | Restrict rows to a start and end date (for example, `05/25/2025 – 05/25/2026`) | | **Export** | Download the filtered table for offline analysis | ### Billing Period and Calendarized tabs Switch between two views of the same underlying data. | Tab | Purpose | | - | - | | **Billing Period** | One row per billing period as utilities report it | | **Calendarized** | Usage and cost spread across calendar months for consistent reporting | ![Building Energy Data Table with Billing Period tab selected showing Period Type dropdown Delivery filter chip date range 05/25/2025 to 05/25/2026 Export button, and table with Meter State Service Type Account Number Charges, Currency, Usage, Usage Unit, and Estimated columns for meters MTR-100856-E01 MTR-100856-G01 and MTR-100856-PV01](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-data-table.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=ca8e89d7f45fb17f6412d5bf794d02a1) Data Table Billing Period tab with meter and usage columns On **Calendarized**, each row aligns usage and cost to calendar months. The column set matches **Billing Period**, including **Data Origin**, **Start Date**, and **End Date** when you scroll horizontally. Use this tab when monthly reports or targets need month-bound totals rather than irregular bill cycles. ![Building Energy Data Table with Calendarized tab selected showing Full Service filter chips date range 05/25/2025 to 05/25/2026 Export button, and table with Meter State Service Type Account Number Charges Usage in kWh and Estimated false for Electric and Natural Gas meters](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-data-table-calendarized.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=4ce1bae96de2cf8053e5559b88ff23bd) Data Table Calendarized tab with month-aligned billing rows ### Table columns Sort any column with the header arrows. Scroll horizontally to reach all fields, including meter, service type, charges, usage, `Estimated`, and `Data Origin`. For every column definition, see [data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). > [!NOTE] > > Rows with **Data Origin** of `System Accrual` fill gaps until a final provider bill arrives. Check **Estimated** and the billing dates before you use accrual rows in compliance or year-end reporting, even when **Estimated** is `false`. ### Pagination The footer shows page numbers and **Lines per page** (for example, 1–31 of 31 on **Calendarized**). Use the arrows when the building has more rows than fit on one page. Compare building rows to the [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) Data Table when you audit the same meters across multiple properties. ## Baseline Analysis Select **Baseline Analysis** from the Energy secondary menu to compare actual energy use against configured baselines, expected use, and weather-normalized (Usage adjusted to a normal-weather equivalent using a regression model.) values. For how these comparisons work, see [Baselines and weather normalization](/products/energ/concepts/baselines-and-weather-normalization). Before you rely on these charts in targets or M\&V, set baseline windows on [Configure building baseline windows](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows). Click **Edit Configuration** on this report to open the energy, water, and waste baseline editor. ### Controls | Control | Purpose | | - | - | | **Date range** | Set the months included in KPIs, charts, and tables (for example, `06/25/2025 – 05/25/2026`) | | **Service type** | Filter to one utility category when the dropdown is set | | **Building** | Confirm the site in view when your account can access multiple locations | ### Summary KPIs Four cards at the top roll up performance for the selected range. | KPI | What it shows | | - | - | | **Actual Usage** | Total measured consumption in kWh for the period | | **Baseline Usage** | Total usage from the configured baseline model | | **Actual vs Expected Usage** | Gap between actual and model-expected use | | **Actual vs Weather Normalized Usage** | Gap between actual and weather-adjusted use | ### Monthly Analytics chart The **Monthly Analytics** chart combines usage bars with degree-day lines. | Series | What it shows | | - | - | | **Baseline Usage** (gray) | Configured baseline consumption by month | | **Actual Usage** (teal) | Measured consumption by month | | **Weather Normalized Usage** (green) | Usage adjusted for weather | | **Expected Usage** (pink) | Model-expected consumption by month | | **HDD (65°F base)** (red line) | Heating degree days on the right axis | | **CDD (65°F base)** (blue line) | Cooling degree days on the right axis | Months without final bills may show only baseline bars while actuals are still accruing. ![Building Energy Baseline Analysis page for KODE Labs Office with date range 06/25/2025 to 05/25/2026, KPI cards for Actual Usage Baseline Usage and variance metrics, and Monthly Analytics chart with Baseline Actual Weather Normalized and Expected usage bars plus HDD line by month](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-baseline-analysis.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=ab894f5fa427ec832493a0a616111294) Baseline Analysis KPIs and Monthly Analytics chart ### Monthly detail tables Scroll below the chart for month-by-month tables. Each table uses the same month columns across the selected range. **Actual Usage** lists **Baseline Usage**, **Actual Usage**, **Expected Usage**, and **Weather Normalization Usage** in kWh. Dashes indicate months still open or not yet calendarized. **Weather Data** compares **15Y Average Temperature** and **Actual Temperature** in °F. **Heating Degree Days (HDD)** and **Cooling Degree Days (CDD)** tables include long-term averages, **65°F base** values, and **Delta** columns so you can see how current weather diverges from the norm. ![Baseline Analysis monthly tables showing Actual Usage with Baseline Actual Expected and Weather Normalized kWh by month, Weather Data with 15Y Average and Actual Temperature, and HDD and CDD tables with 15 year average 65 degree base and Delta rows from June 2025 through May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-energy-baseline-analysis-tables.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=c824276b33407f995e2b3af7c99f7498) Baseline Analysis monthly usage and weather tables Use these tables when you need exact kWh or degree-day values for a single month. Pair the dashboard with **Usage Compared to Baseline** on [Monthly Reports](/products/energ/analytics/building-dashboards-energy#usage-compared-to-baseline) for a simpler month-over-month view. ## Export Energy dashboard data Export spreadsheet-ready data from dashboard charts and pages. The file reflects the filters, date range, and site scope active on screen. **1. Set the view** Open the Energy report you need (for example, Monthly Reports, Target, or Data Table). Apply filters and the date range you want in the export. **2. Download** Select the download control on the page or chart. Save the Excel file when your browser prompts you. > [!NOTE] > > Export mirrors the filtered view. It does not replace [Report Builder](/products/energ/finance/reporting) for custom report layouts. PDF or image-only export is not included. ## Next steps > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Compare this building to portfolio totals and peer sites. > [card] [KODE OS data source](/products/energ/data-sources/kode-os-data-source) > > Connect interval meters for sub-daily trends. > [card] [Building meters](/products/energ/buildings/meters) > > Trace usage or cost to a specific meter record. > [card] [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) > > Configure building baseline windows and portfolio models. # Building Waste dashboard Source: https://docs.kodelabs.com/products/energ/analytics/building-dashboards-waste Review building-level waste quantities, costs, diversion rate, and composition charts in EnerG The building **Waste** dashboard shows how one site performs on waste quantity, cost, and diversion. In the [building view](/products/energ/get-started/navigation#building-view), open `Dashboards` in the left sidebar, then select `Waste`. The page header reads **Waste** with the subtitle *Review your building waste usage & reporting.* Unlike Energy and Water, the Waste dashboard uses a single view without a secondary report menu. ![Building Waste dashboard for Gateway Professional Center showing Add Waste Data and Create Meter buttons Pounds unit date range 01/01/2026 to 05/25/2026, KPI cards for Total Waste Diverted Waste Diversion Rate Data Capture Rate and Total Cost, Monthly Waste Quantity chart for Composted, and Monthly Waste Cost chart](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-waste-overview.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=abce083e0aa11bfedabd1d9ec2f859f5) Building Waste dashboard with KPI cards and monthly quantity and cost charts > [!NOTE] > > Building Waste reports apply to the site you selected in the top bar. Portfolio rollups live on the [Portfolio Waste dashboard](/products/energ/analytics/portfolio-dashboards-waste). ## Controls | Control | Purpose | | - | - | | **Add Waste Data** | Open the form to record a pickup against an existing waste stream | | **Create Meter** | Define a new waste stream with disposal method, waste type, unit, and currency | | **Unit** | Display quantities in **Pounds**, kilograms, or other supported units | | **Date range** | Set the period for KPIs and charts (for example, `01/01/2026 – 05/25/2026`) | Waste data is usually entered manually because automated hauler feeds are uncommon. Use **Create Meter** to define streams, then **Add Waste Data** for each pickup. ## Summary metrics Five KPI cards appear below the header. | Metric | What it shows | | - | - | | **Total Waste** | Combined waste quantity for the selected period, such as **250 lbm** | | **Diverted Waste** | Quantity routed away from landfill | | Diversion Rate (Share of total waste routed away from landfill.) | Percentage of total waste diverted, such as **100%** when all reported material is diverted | | Data Capture Rate (How completely reported waste covers the streams you expect to track.) | How completely waste streams are reported relative to expectations | | **Total Cost** | Waste management spend for the period | ## Monthly waste charts ### Monthly Waste Quantity The **Monthly Waste Quantity** chart stacks or groups waste by disposal method each month. * **Composted** — material sent to composting (typically shown in green) * **Disposed** — material sent to landfill or disposal (typically shown in brown when present) Use this chart to see whether diversion improves month over month. ### Monthly Waste Cost The **Monthly Waste Cost** chart shows total waste management spend by month. Compare it with quantity trends to spot cost-per-unit changes. ## Diversion and composition Scroll below the monthly charts for diversion performance and composition breakdowns. ![Diversion and Data Capture Rate chart with Diversion Rate blue bars at 100 percent for March and April 2026 and Data Capture Rate yellow line by month from January through May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-waste-diversion-capture.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e197c8a0bd7220f236e9d32a086c644d) Diversion rate and data capture rate by month ### Diversion and Data Capture Rate **Diversion Rate** bars show the share of waste diverted each month. **Data Capture Rate** (yellow line) shows reporting completeness over the same period. A high diversion rate with a low capture rate can mean incomplete stream coverage rather than strong diversion performance. ![Waste Composition by Stream bar chart with Cardboard Corrugated and Compostable Mixed in lbm, and Waste Composition by Disposal Method chart with Composted bar in lbm](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-waste-composition.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=21e8687a44de96f8d7a35ed31add7ea2) Waste composition by stream and disposal method ### Waste Composition by Stream The **Waste Composition by Stream** chart groups quantity by material category, such as **Cardboard/Corrugated** and **Compostable - Mixed**. ### Waste Composition by Disposal Method The **Waste Composition by Disposal Method** chart totals quantity by outcome, such as **Composted**. Compare it to the stream chart to confirm disposal methods align with material types. ## Create waste streams A waste stream combines disposal method, material type, and measurement settings. Define streams once, then post recurring pickups against them. **Disposal method** `String` Composted, disposed, donated or reused, or recycled value that matches hauler invoices. **1. Click Create Meter** On the **Waste** dashboard, click **Create Meter**. The **Waste Meter Management** form opens. **2. Choose disposal method** Pick **Composted**, **Disposed**, **Donated or reused**, or **Recycled** to match vendor reporting. ![Waste Meter Management form showing Meter Name, Meter Number, Description, Provider, Disposal Method dropdown with Composted and Disposed options, Waste Type, and Currency fields overlaid on the Waste dashboard](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-waste-create-stream.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=286df8fb1a40714df6004b35f8210550) Waste Meter Management form with disposal method dropdown **3. Select waste type and units** Choose a category such as appliances, batteries, or cardboard. Set the unit of measure and **Currency** for cost fields. **4. Save the stream** Click **Save**. The stream appears for data entry and in monthly charts. ## Add waste data Each entry records quantity, cost, and service timing. Attach ticket PDFs and notes for audit trails. **1. Click Add Waste Data** Click **Add Waste Data** in the header. **2. Select the stream and enter values** Choose the **Waste Stream** meter, then enter **Quantity** and **Cost** when available. ![Add Waste Data panel with Switch to Bulk Import link, Waste Stream meter selector, Quantity and Cost fields, Date picker, File upload area, and Note field overlaid on the Waste dashboard](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-waste-add-data.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=bf00d39a619618322673818bb0616b29) Add Waste Data form with quantity, cost, and file upload **3. Set service date** Choose the pickup date. EnerG allocates the amount to the pickup month. **4. Attach documentation and save** Upload a PDF waste ticket, add **Note** text for anomalies, then click **Save**. > [!TIP] > > Confirm the pickup month matches the hauler invoice before you share diversion metrics. > [!TIP] > > Use **Switch to Bulk Import** in the **Add Waste Data** panel when you need to load many pickups from a spreadsheet. > [!WARNING] > > Missing pickups understate diversion rates until you backfill the month. Plan monthly reviews when waste data is entered manually. ## Next steps > [card] [Manual entry](/products/energ/data-sources/manual-entry) > > Create manual waste meters when streams are not tied to a utility feed. > [card] [Portfolio Waste dashboard](/products/energ/analytics/portfolio-dashboards-waste) > > Compare this building to portfolio totals and peer sites. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Review electricity and fuel usage for the same building. > [card] [Building Water dashboard](/products/energ/analytics/building-dashboards-water) > > Review water consumption and cost for the same building. # Building Water dashboard Source: https://docs.kodelabs.com/products/energ/analytics/building-dashboards-water Review building-level water usage, cost, year-over-year comparisons, and baseline charts on Monthly Reports in EnerG The building **Water** dashboard shows how one site performs on water consumption, cost, and baseline (A fixed historical reference window you measure current usage against.) comparisons. In the [building view](/products/energ/get-started/navigation#building-view), open `Dashboards` in the left sidebar, then select `Water`. The page header reads **Water** with the subtitle *Water Use, Efficiency, and Performance Overview.* `Monthly Reports` opens by default. A secondary menu lists other report types such as `Annual Reports`, `Comparison`, `Target`, `Data Quality`, and `Data Table`. ![Building Water dashboard for Gateway Professional Center with Monthly Reports selected, Usage toggle active, date range 06/25/2025 to 05/25/2026, Usage Compared to Previous Year bar chart with teal current year and gray prior year bars in liters, and Difference percentage chart below](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-monthly-reports-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e01b370230f4af2495fddf387f842b9f) Building Water Monthly Reports with Usage selected and year-over-year comparison ## Water report menu After you select `Water` under `Dashboards`, use the secondary menu to switch report types. | Report | What it shows | | - | - | | `Monthly Reports` | Month-by-month usage or cost with year-over-year and baseline charts | | `Annual Reports` | Annual summaries by service type and meter | | `Comparison` | Side-by-side comparison of two time periods | | `Target` | Reduction goals and variance charts ([Target](#target)) | | `Data Quality` | Completeness and billing gaps for water meters at this building | | `Data Table` | Raw billing data in a sortable table | > [!NOTE] > > Building Water reports apply to the site you selected in the top bar. Portfolio rollups live on the [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water). ## Monthly Reports controls The control row at the top of **Monthly Reports** sets the metric lens and reporting window. | Control | Purpose | | - | - | | **Usage / Cost** | Switches every chart between consumption in liters (L) and billed cost | | **Date range** | Select start and end months (for example, `06/25/2025 – 05/25/2026`) | All charts on the page refresh together when you change the toggle or date range. ## Usage lens Select **Usage** on the toggle to view consumption charts in **L** (liters). ### Usage Compared to Previous Year The top chart compares current-period water use to the same months in the prior year. * **Teal bars** — current reporting period * **Light gray bars** — previous year * **Striped bars** — accrued or estimated months without final bills The **Difference** chart below shows the percentage change between periods. Red values indicate increases; teal values indicate decreases. > [!WARNING] > > Treat striped bars as estimates until final bills post and replace accrued values. ### Usage per Service Type The **Usage per Service Type** chart groups consumption by utility category each month. For most buildings, water appears as a single **Water** series. ![Usage per Service Type chart with blue Water bars by month from June 2025 to March 2026 in liters with striped bar for March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-usage-per-service-type.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=5c9f2fee33297ecdab4c51afa3c1e671) Usage per Service Type bar chart by month for water ### Usage per Meter The **Usage per Meter** chart breaks monthly consumption down by individual water meter or account. ![Usage per Meter chart with yellow bars by month from June 2025 to March 2026 in liters with striped bar for March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-usage-per-meter.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b08efe796b22f7f1b93a3c997b0a27e6) Usage per Meter bar chart by month for water Compare meter bars when you trace a spike to a specific account. Pair this view with [Building meters](/products/energ/buildings/meters) when you need meter configuration detail. ### Usage Compared to Baseline The **Usage Compared to Baseline** chart compares actual consumption to the baseline you configured for the building. ![Usage Compared to Baseline chart with Actual vs Baseline legend showing teal actual bars and light gray baseline bars by month from June 2025 to May 2026 with striped actual bar for March 2026 and baseline-only bars for April and May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-usage-compared-to-baseline.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=df7c24f03fc3ca4d7939ba6e5d09f276) Usage Compared to Baseline with Actual and Baseline bars by month * **Baseline** — light gray bars * **Actual** — dark teal bars * **Striped segments** — projected or incomplete actuals for the month Configure baselines for the water category on [Configure building baseline windows](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows). ## Cost lens Select **Cost** on the toggle to view billed charges in your configured currency. ### Cost Compared to Previous Year The layout matches the usage view. **Cost Compared to Previous Year** shows current and prior-year spend by month. The **Difference** chart below reports percentage change in cost. ![Building Water dashboard with Cost selected showing Cost Compared to Previous Year bar chart with teal current year and gray prior year bars in US dollars and Difference percentage chart with red increases and teal decreases from June 2024 through March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-cost-compared-to-previous-year.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=8bb2df1acb8165d41c536d806366cc9c) Cost Compared to Previous Year with current and prior year bars and variance chart Teal bars represent the current period. Gray bars represent the prior year. Striped bars indicate accrued or estimated cost for months without final bills. ### Cost per Service Type The **Cost per Service Type** chart groups water spend by category each month. Most buildings show a single **Water** series. ### Cost Compared to Baseline The **Cost Compared to Baseline** chart compares actual spend to the cost baseline you configured for the building. ![Cost per Service Type chart with blue Water bars by month from June 2025 to March 2026 with striped March bar, and Cost Compared to Baseline chart below with gray Baseline and teal Actual bars including baseline-only months for April and May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-cost-per-service-type-baseline.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e7017d74fa1a277e1b80fe801d0375d6) Cost per Service Type and Cost Compared to Baseline by month * **Baseline** — light gray bars * **Actual** — dark teal bars * **Striped segments** — projected or incomplete actuals for the month ### Cost per Meter The **Cost per Meter** chart shows monthly spend by individual water meter or account. ![Cost per Meter chart with yellow bars by month from June 2025 to March 2026 in US dollars with striped bar for March 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-cost-per-meter.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=ad780387f35c321a691ccbb4a435cbc7) Cost per Meter bar chart by month for water > [!TIP] > > Keep one date range while you switch between **Usage** and **Cost** so month-to-month comparisons stay aligned across charts. ## Annual Reports Select `Annual Reports` from the Water secondary menu to compare years for the selected building. The page header and **Usage / Cost** toggle behave the same as Monthly Reports. The date control uses a **year range** (for example, `2021` to `2025`) instead of month-by-month selection. ### Usage lens With **Usage** selected, the main card is **Usage and Usage per Area**. It contains two bar charts that share the same year axis. ![Building Water Annual Reports with Usage selected showing Usage per Area chart in L per ft squared and Usage Analysis chart in liters by year from 2021 to 2025 for Gateway Professional Center](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-annual-reports-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=a58a4d596ed0d135e08b4f6e9c9e8fc5) Annual Reports Usage view with Usage per Area and Usage Analysis by year | Chart | What it shows | | - | - | | **Usage per Area** | Water use intensity (Water Use Intensity: water consumption normalized by floor area.) in **L/ft²** by calendar year | | **Usage Analysis** | Total building water consumption in **L** by calendar year | Scroll below the paired charts for **Usage per Service Type**. #### Usage per Service Type The **Usage per Service Type** chart groups annual volume by category. Most buildings show a single **Water** series. ![Annual Usage per Service Type chart with blue Water bars by year from 2021 to 2025 in liters near 9 million to 10 million L](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-annual-usage-per-service-type.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=50613d6cb266e748fa34d6617e12a7af) Annual Usage per Service Type bar chart by year for water Compare annual usage to [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water) Annual Reports when you place one building in portfolio context. ### Cost lens Select **Cost** on the toggle to open **Cost and Cost per Area** with the same paired-bar layout. ![Building Water Annual Reports with Cost selected showing Cost Analysis chart in US dollars and Cost per Area chart in dollars per ft squared by year from 2021 to 2025](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-annual-reports-cost.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=12193f91533c463acd23e8c8ecef5362) Annual Reports Cost view with Cost Analysis and Cost per Area by year | Chart | What it shows | | - | - | | **Cost Analysis** | Total water utility spend in your configured currency by calendar year | | **Cost per Area** | Cost intensity in **\$/ft²** by calendar year | #### Cost per Service Type The **Cost per Service Type** chart groups annual water spend by category. ![Annual Cost per Service Type chart with blue Water bars by year from 2021 to 2025 in US dollars near 20000 to 21000](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-annual-cost-per-service-type.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=05415f8f9e52ef02ae580f64922f9795) Annual Cost per Service Type bar chart by year for water ## Target Select `Target` from the Water secondary menu to compare actual building performance against a reduction target and historical baseline. Create and assign targets on [Portfolio targets](/products/energ/analytics/portfolio-targets). For energy commodity targets, use **Target** on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#target). ### Controls | Control | Purpose | | - | - | | **Break down by service type** | Split charts by utility category when enabled | | **Target** | Select which reduction goal to display (for example, `2040 Water Reduction`) | Charts use the unit configured for the target, such as **m³** (cubic meters). ### Charts Three charts stack on the Target page. | Chart | What it shows | | - | - | | **Target Water Comparison** | **Actual** (solid teal), **Target** (dotted blue), and **Baseline** (solid black) trends over time | | **Delta from Target** | Monthly gap between actual use and the target trajectory. Red bars mean actual exceeded the target; teal bars mean actual fell below the target | | **Delta from Baseline** | Monthly difference between actual use and the baseline period. Teal bars below zero indicate savings relative to baseline | ![Building Water Target page with 2040 Water Reduction selected, Target Water Comparison line chart with Actual Target and Baseline in cubic meters from December 2022 to February 2026, Delta from Target red bar chart, and Delta from Baseline teal bar chart](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-target.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=2ea0efb6f507dfbffbeef56ad0d97622) Building Water Target view with comparison and delta charts Red bars in **Delta from Target** often grow when the target line slopes down but actual use stays flat. Teal bars in **Delta from Baseline** show months where actual use stayed below the historical baseline. ## Data Quality Select `Data Quality` from the Water secondary menu to review billing coverage for every water meter assigned to the building. Use this view before you share monthly or target charts when gaps might skew the story. ### Controls | Control | Purpose | | - | - | | **Date range** | Limit the timeline and table rows to a start and end date (for example, `06/25/2025 – 05/25/2026`) | ### Bills Data Quality chart The **Bills Data Quality** chart is a horizontal timeline with one row per meter. Color segments classify each billing period by coverage. For what each legend color means, see [data quality legend](/products/energ/reference/data-and-meter-fields#data-quality-legend). Solid green bars across a meter row mean every month in range has complete coverage. ![Building Water Data Quality page with date range 06/25/2025 to 05/25/2026, Bills Data Quality horizontal chart with Complete green bar for meter MTR-100856-W01, and detail table with Meter Number Type Service Type Water Usage in gal and Start Date End Date columns](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-data-quality.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=1ae6fd3f464744ebf63d4c9ebd3827e3) Data Quality timeline and billing detail table for water ### Billing detail table The table below the chart lists individual billing records for water meters in the selected period. Sort any column to find gaps or outliers. Columns include meter number, coverage type, provider, service type, account, deregulation status, usage, and billing dates. A **Complete** row with matching start and end dates confirms that period counts toward completeness scoring. See [Data completeness](/products/energ/data-quality/data-completeness) for how scores roll up to the building, and [Data quality overview](/products/energ/data-quality/data-quality-overview) for alerts and portfolio workflows. ## Data Table Select `Data Table` from the Water secondary menu to audit line-level billing and calendarized records for the selected building. Use this view when you need to verify a specific meter, charge, or billing period behind a chart. ### Controls | Control | Purpose | | - | - | | **Period Type** | Control how periods are grouped in the grid | | **Service tags** | Filter by category with active chips such as `Full Service` or `Delivery` | | **Date range** | Restrict rows to a start and end date (for example, `05/25/2025 – 05/25/2026`) | | **Export** | Download the filtered table for offline analysis | ### Billing Period and Calendarized tabs Switch between two views of the same underlying data. | Tab | Purpose | | - | - | | **Billing Period** | One row per billing period as utilities report it | | **Calendarized** | Usage and cost spread across calendar months for consistent reporting | ![Building Water Data Table with Billing Period tab selected showing Period Type dropdown Full Service filter chips date range 05/25/2025 to 05/25/2026 Export button, and table with Meter MTR-100856-W01 State California Service Type Water Account Number ACT-100856 Charges Usage in gal Estimated and Data Origin columns](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-data-table-billing.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=1e2eb359c024a0757f674fdb0271c1e0) Data Table Billing Period tab with water meter and usage columns On **Calendarized**, each row aligns usage and cost to calendar months. Scroll horizontally to reach **Meter**, **Data Origin**, **Start Date**, and **End Date** when they are not visible in the default view. ![Building Water Data Table with Calendarized tab selected showing Full Service and Delivery filter chips date range 05/25/2025 to 05/25/2026 Export button, and table with State California Service Type Water Usage in L Data Origin System Accrual and Provider rows by month](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-water-data-table-calendarized.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=2d9f7bd5cfe7977486d18d850d3a1afc) Data Table Calendarized tab with month-aligned water billing rows ### Table columns Sort any column with the header arrows. Scroll horizontally to reach all fields, including meter, service type, charges, usage, `Estimated`, and `Data Origin`. For every column definition, see [data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). > [!NOTE] > > Rows with **Data Origin** of `System Accrual` fill gaps until a final provider bill arrives. Check **Estimated** and the billing dates before you use accrual rows in compliance or year-end reporting, even when **Estimated** is `false`. ### Pagination The footer shows page numbers and **Lines per page**. Use the arrows when the building has more rows than fit on one page. Compare building rows to the [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water) Data Table when you audit the same meters across multiple properties. ## Other report types Select `Comparison` from the secondary menu when you need period-over-period water analysis at building scope. ## Next steps > [card] [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water) > > Compare this building to portfolio totals and peer sites. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Review electricity and fuel usage for the same building. > [card] [Building meters](/products/energ/buildings/meters) > > Trace water usage to a specific meter record. > [card] [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) > > Configure baseline windows that drive water comparison charts. # Portfolio budget and planning Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-budgets Track portfolio budget performance on Overview and review monthly plans on Planning in EnerG Review portfolio-wide budgets in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Click `Budget` in the left sidebar to open **Portfolio Budget Overview** and **Portfolio Budget Planning**. Overview compares actual spend, accruals (Accruals estimate usage or cost for months that lack final bills.), and variance (Variance is the difference between budget and actual, in value and percent.) by building. Planning shows monthly budget plans by service type in consumption, cost, or carbon. To configure budget models for one site, open the [building view](/products/energ/get-started/navigation#building-view) and use [Model configuration](/products/energ/finance/budgets) under `Budget`. For building-level budget creation, use [Budget planning](/products/energ/finance/budget-planning). For how predicted, actual, and variance relate, see [Budgets and capital planning](/products/energ/concepts/budgets-and-capital-planning#predicted-actual-and-variance). ## Navigate to portfolio budgets Click `Budget` in the portfolio left sidebar. Switch between **Overview** and **Planning** from the breadcrumb or tabs at the top of the page. ## Portfolio Budget Overview **Portfolio Budget Overview** tracks portfolio energy spend and compares performance against budget for the sites and period you select. ![Portfolio Budget Overview with Building Type Country State and District filters, date range Jan 2026 to Jun 2026, KPI cards for On Track Total Budget Actual Spend and Variance vs Budget, YTD Actual vs Expected by service type chart, Monthly Budget Comparison chart, and Breakdown by Building table](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-budget-overview.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=617055f36869a6233702165d4fafef13) Portfolio Budget Overview with KPI cards, budget vs actual charts, and building breakdown ### Summary KPI cards Four cards roll up portfolio totals for the active filters and date range. | Card | What it shows | | - | - | | **On Track** | Count and share of buildings within budget | | **Total Budget** | Sum of budgets for the selected period | | **Actual Spend** | Sum of actual spend for the selected period | | **Variance vs Budget** | Portfolio variance in percent and currency. Negative values mean under budget | ### Page controls Use the filter bar and date range to align the view with your reporting scope. | Control | Purpose | | - | - | | **Building Type** | Limit results by property category | | **Country** / **State / Province** / **District** | Geographic filters for the portfolio | | **Date range** | Period for KPI cards, charts, and tables | | **Service type tabs** | Switch charts between All Utilities, Electric, Gas, Water, Steam, and other configured service types | ### Charts | Chart | What it shows | | - | - | | **YTD Actual vs. Expected by Service Type** | Monthly budget and actual bars with variance percent, filtered by service type tab | | **Monthly Budget Comparison** | Budget versus actual by month with a supporting monthly table | | **Most Off-Track Buildings** | Buildings ranked by variance percent, over budget and under budget | ![Portfolio Budget Overview with Budget vs Actual monthly chart and Most Off-Track Buildings horizontal bar chart showing over-budget buildings in red and under-budget buildings in green](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-budget-overview-off-track.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=ed0c4e63dc0572e7a3ddb681f65f660e) Portfolio Budget Overview highlighting buildings most off track ### Building comparison table Each row summarizes one building. Use status labels such as **Over Budget**, **Slightly Over**, **On Track**, and **Under Budget** with trend charts to prioritize follow-up. | Column | Description | | - | - | | **Building Name** | Site name | | **Building Type** | Property category such as Office | | **Location** | City and state or province | | **Utilities Included** | Service types included in the rollup | | **Budget** / **Actual** | Planned and actual spend for the period | | **Variance** / **Variance %** | Difference from budget in currency and percent | | **Status** | On-track label for the building | | **Trend** | Mini chart of recent budget performance | ### Export budget data Use the download action on Overview or Planning to export budget data for the active filters. One export can include **all service types** so you do not download and merge separate files per fuel. Export accruals at meter level when you need actual versus budget with accrual values for review. ## Portfolio Budget Planning **Portfolio Budget Planning** shows monthly budget plans for a single **Service Type** and year across the portfolio. Choose `Electric`, `Natural Gas`, `District Steam`, or `Fuel Oil No 4` from the **Service Type** dropdown. Units and summary cards update for the commodity you select. ![Portfolio Budget Planning page with Service Type Electric and year 2026 filters, summary cards for Cost Carbon Emissions Sites with Budget and Total Sites, Search and Building Type filters, Consumption Cost and Carbon view toggles, and a table with monthly columns Jan through May 2026 showing kWh values for One Financial Plaza Summit Ridge Plaza Ironworks District and Centennial Square](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-budget-planning.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=f5a73e30812a1b48d0d7e45cec2480f2) Portfolio Budget Planning with summary cards and a monthly consumption table ### Summary cards Four cards summarize the selected service type and year. | Card | What it shows | | - | - | | **Cost** | Total planned cost for filtered buildings | | **Carbon Emissions** | Planned emissions in kgCO₂e | | **Sites with Budget** | Count of buildings that have a budget for this service type | | **Total Sites** | Count of buildings in the portfolio | ### Page controls | Control | Purpose | | - | - | | **Starred** | Limit the table to starred buildings | | **Service Type** | Commodity for the plan: `Electric`, `Natural Gas`, `District Steam`, or `Fuel Oil No 4` | | **Year** | Calendar year for monthly columns | | **Download** | Export the current table view | Use **Search** and **Building Type** above the table to narrow the building list. ### Switch Consumption, Cost, or Carbon Three toggles change how monthly values display in the table. ![Segmented control with Consumption Cost and Carbon options where Cost is selected with a white background](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-budget-view-toggle.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=e22f43c35ecb212efa4e788c8dbd3006) Consumption, Cost, and Carbon view toggles on Portfolio Budget Planning | View | What the table shows | | - | - | | **Consumption** | Planned usage by month in the unit for the selected service type (for example, kWh for `Electric` or ccf for `Natural Gas`) | | **Cost** | Planned spend by month in your configured currency | | **Carbon** | Planned emissions by month | Click a **Building** name in the table to open building-level budget detail for that site. ### Download the budget report Click `Download` on **Portfolio Budget Planning** to export the current view. EnerG generates an Excel workbook (`.xlsx`) that matches your active **Service Type**, **Year**, and table filters. The file includes both tabular data and chart-ready series you can use in Excel or Power BI. Download the [example portfolio budget export for 2026 (Electric)](/downloads/energ-portfolio-budget-planning-example-2026.xlsx) to review workbook layout, summary tabs, and chart data sheets before you export from your workspace. **1. Set filters on Planning** Choose **Service Type**, **Year**, and any building filters you need. Switch **Consumption**, **Cost**, or **Carbon** if you want the on-screen view aligned with what you export. **2. Click Download** Click `Download` in the top-right corner. Save the file when your browser prompts you. **3. Open the workbook** Start on **Table of Contents**. It lists every sheet, the date range, service type, and when EnerG generated the export. #### Workbook sheets | Sheet | Contents | | - | - | | **Table of Contents** | Export date range, service type, generation time, and an index of all sheets | | **Budget portfolio** | Export settings, portfolio summary totals, and a buildings-by-month table with consumption, unit, cost, and carbon columns per month | | **By month** | Portfolio totals for each month in the range (consumption, cost, and related totals) | | **By building** | One row per building with total consumption, cost, and CO₂ for the period, sorted by cost | | **Metadata** | Export parameters such as start date, end date, service type, and generated timestamp | | **\_bp\_chart** | Chart data for portfolio totals by month (for example, month and total cost) | | **\_bb\_chart** | Chart data for totals by building (building name and total cost) | The main **Budget portfolio** sheet holds the detailed grid you see in the product: one row per building and paired columns per month for consumption, unit, cost, and emissions where applicable. The **\_bp\_chart** and **\_bb\_chart** sheets supply the underlying series for charts in the workbook. Use them when you rebuild visuals in Excel or connect the export to another reporting tool without re-aggregating the main table. > [!TIP] > > Open **By month** or **By building** when you need portfolio rollups only. Use **\_bp\_chart** or **\_bb\_chart** when you want ready-made series for line or bar charts. > [!NOTE] > > Sheet names and row counts depend on how many buildings and months match your filters. A portfolio export for one service type and calendar year typically includes a summary block, a multi-month building table, and separate chart data tabs. ## Accruals On **Overview**, turn **Accruals** on to include accrued amounts in **Actual**, **Variance**, and **Projected** columns. For how EnerG builds and trues up accruals, see [Accruals](/products/energ/concepts/budgets-and-capital-planning#accruals) and the [accrual behavior reference](/products/energ/reference/calculations-and-parameters#accruals). > [!NOTE] > > Accrual behavior may vary by deployment. Confirm labels and calculations in your workspace before you publish variance reports. ## Next steps > [card] [Building budget overview](/products/energ/finance/budget-overview) > > Review actual, variance, and charts for one building. > [card] [Model configuration](/products/energ/finance/budgets) > > Configure monthly budget values for one building. > [card] [Budget planning](/products/energ/finance/budget-planning) > > Create and activate building budgets with the six-step wizard. > [card] [Report Builder](/products/energ/finance/reporting) > > Export budget and actual metrics for reporting cycles. > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Compare usage and cost trends with budget performance. # Portfolio capital planning Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-capital-planning Compare conservation scenarios and review the capital planning roadmap across your portfolio in EnerG Use `Capital Planning` in the [portfolio view](/products/energ/get-started/navigation#portfolio-view) to compare conservation scenarios (A scenario bundles measures into a funding package with priority and dates.) across buildings. The **Scenario Comparison** page rolls up investment, savings, and long-range projections. You create a comparison by selecting buildings and scenarios, then review the **Capital Planning Roadmap** chart and detail table. Baseline setup, utility rates, and measure (A conservation measure is one project with savings, capital cost, and incentives.) definitions happen at the building level. After you select a site, open [Capital planning](/products/energ/sustainability/capital-planning) in the building view to create measures and scenarios. For the underlying concepts, see [Measures, curves, and scenarios](/products/energ/concepts/budgets-and-capital-planning#measures-curves-and-scenarios). ## Navigate to Scenario Comparison Click `Capital Planning` in the portfolio left sidebar. The **Scenario Comparison** page opens with the subtitle *Select buildings and scenarios for portfolio-level energy planning and analysis.* ![Scenario Comparison page with Buildings Total Investment and Energy Savings summary cards, Create Comparison button, Capital Planning Roadmap line chart from 2025 to 2050 showing Baseline Target and Combined TTM Forecast lines, Consumption Cost and Emissions toggles, and Energy and target dropdown filters](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-comparison.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=ea2b125c5a7ff7a323891145394034af) Scenario Comparison page with summary cards and the Capital Planning Roadmap chart ### Summary cards Three cards summarize the active comparison. | Card | What it shows | | - | - | | **Buildings** | Count of buildings included in the comparison | | **Total Investment** | Sum of capital expenditure across selected scenarios | | **Energy Savings** | Total projected energy savings for the comparison | ## Create a comparison Click `+ Create Comparison` in the top-right corner. EnerG walks you through building selection, then scenario selection. **1. Select buildings** In the **Select Buildings** dialog, search for sites by name. Check each building you want in the comparison, then click `Next`. The table lists **Building**, **Type**, and **Address** for each site. ![Select Buildings modal with Search field containing kode, a table showing KODE 1420 Office checked as Office type at 1420 Washington Boulevard Detroit, and Cancel and Next buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-select-buildings.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=b793823bd2ac841be09a99b44c4973d3) Select Buildings dialog when creating a comparison **2. Choose scenarios** On the **Choose Scenarios** page, expand each building row and check the scenarios you want to compare. Priority badges such as **High Priority** or **Medium Priority** appear next to scenario names when defined. Click `Save` when your selection is complete. ![Choose Scenarios dialog with Ironworks District expanded showing Low Cost Aggressive with High Priority checked and Deep Retrofit with Medium Priority checked, plus collapsed rows for other buildings, and Previous Cancel and Save buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-choose-scenarios.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=785dd8f781e455b945f5b0130527a67b) Choose Scenarios page with building rows and scenario checkboxes **3. Review the comparison** EnerG returns to **Scenario Comparison** with summary cards, the roadmap chart, and a scenario table for the buildings and scenarios you selected. ## Review selected scenarios The **Selected Scenarios** panel lists each building and the scenarios you included. Expand a building row to see scenario names and priority tags. Use the edit and view icons in the panel header to change the selection or adjust visibility. ![Selected Scenarios card showing Ironworks District expanded with Low Cost Aggressive High Priority and Deep Retrofit Medium Priority listed, edit and view icons in the header](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-selected-scenarios.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=846ea029a0c2f8352b7efcb0918ff4a2) Selected Scenarios panel showing Ironworks District with two scenarios ## Capital Planning Roadmap The **Capital Planning Roadmap** chart projects consumption, cost, or emissions from the current year through 2050. Three series typically appear on the chart. | Series | What it shows | | - | - | | **Baseline** | Projected values without conservation measures | | **Target** | Portfolio or building reduction target trajectory | | **Combined TTM Forecast** | Combined forecast from selected scenarios and measures | Use the **Energy** dropdown (and related resource filters when available) to scope the chart. Use the target or scenario selector to pick which comparison or target drives the **Target** line. ### Switch Consumption, Cost, or Emissions Three toggles change the roadmap and table to a different metric lens. ![Capital Planning Roadmap chart with Consumption toggle selected showing Baseline Target and Combined TTM Forecast lines from 2025 to 2050 and a comparison table for Ironworks District with Low Cost Aggressive and Deep Retrofit scenarios showing savings capex incentives and payback columns](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-roadmap-consumption.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=cdb3553e40b6cb88dd56d1ea395dc327) Capital Planning Roadmap with Consumption selected ![Capital Planning Roadmap with Cost toggle selected, chart showing cost projections, and comparison table with Total Annual Savings Cost and Capex columns for Ironworks District scenarios](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-roadmap-cost.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=5f063ddce3b161382a306d27aa77f7aa) Capital Planning Roadmap with Cost selected ![Capital Planning Roadmap with Emissions toggle selected, chart showing emissions projections, and comparison table with Total Annual Savings CO2e and related columns for Ironworks District scenarios](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-capital-planning-roadmap-emissions.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=0d2e93b53b5820e4cc9e53d8b9641519) Capital Planning Roadmap with Emissions selected | View | What the roadmap and table emphasize | | - | - | | **Consumption** | Energy use and consumption savings | | **Cost** | Spend, cost savings, and financial payback | | **Emissions** | CO₂e impacts and emissions savings | ## Scenario comparison table Below the roadmap, a sortable table compares each selected scenario by building. Columns update when you switch **Consumption**, **Cost**, or **Emissions**, but commonly include: | Column | Description | | - | - | | **Building Name** | Site for the scenario | | **Scenario Name** | Conservation package label (for example, `Low Cost - Aggressive` or `Deep Retrofit`) | | **Total Annual Savings (Consumption)** | Projected annual consumption savings | | **Total Annual Savings (Cost)** | Projected annual cost savings | | **Total Annual Savings (CO2e)** | Projected annual emissions savings | | **Capex** | Capital expenditure for the scenario | | **Incentives** | Rebates or incentives applied | | **Projected Annual Consumption** | Share of baseline consumption after measures | | **Simple Payback (Years)** | Years to recover capex from savings | Use the table to rank scenarios by payback, savings, or emissions impact before you present options to stakeholders. ## Next steps > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Create measures and scenarios at the building level before you compare them in the portfolio. > [card] [Budget planning](/products/energ/finance/budget-planning#step-4-capital-planning) > > Add capital projects from measures into an annual building budget. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Align capital plans with portfolio reduction targets. > [card] [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets) > > Compare budget performance alongside conservation scenarios. # Portfolio certifications Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-certifications Manage and track building certifications, fees, and compliance across your portfolio in EnerG Monitor certification status, fees, and expiration across your portfolio in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Click `Certifications` in the left sidebar to open the dashboard. The page title reads **Certifications** with the subtitle *Manage and track certifications for your buildings.* To add or edit a certification for one building, open the [building view](/products/energ/get-started/navigation#building-view) and use [Building certifications](/products/energ/sustainability/certifications). > [!NOTE] > > EnerG tracks certification status, fees, expiration dates, and historical records. It does not submit or manage certification applications on your behalf. ## Navigate to portfolio certifications Click `Certifications` in the portfolio left sidebar. ![Portfolio Certifications page showing KPI cards for Buildings with Certifications, Inactive Certifications, and Certification Compliance Percentage, filter dropdowns, and Certification Details table with expiration status](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-sustainability-certification-dashboard.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f745887e473fdeda9e367230bcab182c) Portfolio certifications dashboard with KPI cards and detail table ## Summary cards Three cards summarize portfolio certification health. | Card | What it shows | | - | - | | **Buildings with Certifications** | Count of buildings that have at least one active certification record | | **Inactive Certifications** | Certifications marked inactive or no longer in force | | **Certification Compliance Percentage** | Share of certifications that meet your compliance rules | ## Filter the portfolio Use the filter row above the summary cards to narrow the table and charts. | Filter | Purpose | | - | - | | **Region** | Limit results to a geographic region | | **Building Type** | Filter by property type such as Office or Retail | | **Country** | Filter by country | | **Certification Name** | Show one program such as LEED, Energy Star, or WELL Building Standard | | **Expiration Date** | Focus on certifications expiring in a date range | ## Certification Details table The **Certification Details** table lists every certification record in the portfolio. Click a **Building Name** to open that site in the building view. Use the download control to export the filtered certification list to a spreadsheet. ![Certification Details table with Building Name Certification Name Expiration Data Last Reviewed Days to Expiration Responsible and Historical Logs columns including Expired and active day-count badges](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-certifications-details.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=3ff967b576af171d8fce7ae1700ee165) Certification Details table with expiration status and responsible owners | Column | Description | | - | - | | **Building Name** | Site that holds the certification | | **Certification Name** | Program and rating (for example, `LEED - Building Operations and Maintenance (O+M)` or `BOMA - BEST - Gold`) | | **Score** | Program score when tracked (ENERGY STAR, LEED, and other scored programs) | | **Expiration** | Renewal deadline | | **Data Last Reviewed** | Date someone last verified the record in EnerG | | **Days to Expiration** | Countdown to renewal, or an **Expired** badge when the date has passed | | **Responsible** | Person assigned to track renewal | | **Historical Logs** | Click **View History** to see prior entries and changes for that certification | > [!TIP] > > Sort or filter by **Days to Expiration** when you plan renewal work. Address **Expired** rows before you publish compliance or ESG reports. ## Overview charts The **Overview** section includes charts that summarize certification coverage across the portfolio. ![Overview section with Number of Sites By Certification stacked bar chart for BOMA Energy Star Fitwel LEED and WELL Building Standard, and Number of Certifications By Site bar chart listing buildings such as Pacific Heights and Beacon Hill Complex](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-certifications-overview-charts.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1c1d44b43ed865f775c7af3c8c0e8018) Overview charts for sites by certification and certifications by site | Chart | What it shows | | - | - | | **Number of Sites By Certification** | How many buildings hold each certification program. Stacked segments distinguish certification status or tier within each program. | | **Number of Certifications By Site** | How many certifications each building holds. Use this chart to spot sites with heavy certification portfolios. | ## Fee overview The **Fee Overview** charts break down certification-related fees by building and by year. ![Fee Overview per Building stacked bar chart with red and blue segments by building name, and Fee Overview per Year stacked bar chart with yellow and red segments by year from 2011 through 2025](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-certifications-fee-overview.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=3f1ff30a6e3db509a0f2516527fd5a0e) Fee Overview per Building and Fee Overview per Year stacked bar charts | Chart | What it shows | | - | - | | **Fee Overview per Building** | Total certification fees allocated to each building | | **Fee Overview per Year** | How certification fees accumulate across calendar years | Stacked colors represent fee categories configured in your workspace (for example, consulting versus certification fees). ## Cost analysis The **Cost Analysis** section shows total investment across certification programs. ![Cost Analysis section titled Total Investment Analysis Across Certification Programs with Total Investment Consulting Fees and Certification Fees summary values and a stacked bar chart for LEED WELL BOMA Fitwel and Energy Star showing green consulting fees and orange certification fees](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-certifications-cost-analysis.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=b4347a6e3410e13c59dd145d268e0d36) Cost Analysis with total investment summary and fees by certification program ### Summary metrics | Metric | Description | | - | - | | **Total Investment** | Combined consulting and certification fees across programs | | **Consulting Fees** | Professional services tied to certification work | | **Certification Fees** | Direct program or body fees | ### Fees by program The stacked bar chart lists each certification program on the horizontal axis. **Consulting Fees** and **Certification Fees** stack within each bar so you can compare total cost by program (for example, LEED versus WELL Building Standard versus Energy Star). Hover a bar to see program name, certification count, and fee breakdown when your deployment supports tooltips. > [!NOTE] > > Certification data supports environmental, social, and governance reporting when finance and sustainability teams share the same system of record. ## Next steps > [card] [Building certifications](/products/energ/sustainability/certifications) > > Add or update certification records for one building. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Align reduction targets with certified performance goals. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Select a building to manage site-level certifications. > [card] [Capital planning](/products/energ/analytics/portfolio-capital-planning) > > Connect capital programs to certification narratives. # Portfolio Energy dashboard Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-dashboards-energy Review portfolio-level energy usage, cost, and emissions across all buildings The portfolio **Energy** dashboard aggregates metered and billed energy data across every building in KODE OS. In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), open `Dashboards` in the left sidebar, then select `Energy`. ![Portfolio left sidebar showing Dashboards expanded with Energy selected, Water, and Waste listed below](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-dashboards-nav.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=a59ee0eecf1aa642b287b8558f871079) Portfolio Dashboards menu with Energy, Water, and Waste `Energy` loads by default when you first open `Dashboards`. A secondary menu lists portfolio report types. `Monthly Reports` opens first. ## Energy report menu After you select `Energy`, use the secondary menu to switch report types. | Report | What it shows | | - | - | | `Monthly Reports` | Portfolio monthly usage and cost charts by month, service type, and building | | `Annual Reports` | Annual usage and cost by building, service type, EUI (Energy Use Intensity: annual energy divided by conditioned floor area.), and rolling cost intensity | | `Target` | Actual, target, and baseline energy comparison charts for a selected target | | `Data Table` | Sortable billing and calendarized line items with export | > [!NOTE] > > The portfolio Energy menu does not include building-only items such as `Comparison`, `Interval Trends`, or `Data Quality`. Open a building to access those reports on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy). ## Monthly Reports `Monthly Reports` is the default Energy view at portfolio level. The page header reads **Energy** with the subtitle *Energy Use, Efficiency, and Performance Overview.* ### Controls The control area has two rows. The top row sets scope and the metric lens. The second row adds portfolio filters. **Top row** * **Usage / Cost** — switches every chart on Monthly Reports between consumption and billed cost (`Emission` appears when your deployment includes it) * **Starred Buildings** — limit results to favorited sites * **Buildings** — select or deselect individual buildings * **Date range** — pick the start and end months for the reporting window * **Filter** — open advanced filters; an indicator appears when filters are active **Second row** * **Building Type**, **Countries**, **States**, **Brands**, and **Regions** — narrow the portfolio * **Currency** — appears when `Cost` is selected so you view charges in one currency ![Portfolio Energy Monthly Reports filter bar with Usage selected, Starred Buildings toggle, Buildings dropdown, date range 06/22/2025 to 05/22/2026, filter icon, and second row dropdowns for Building Type Countries States Brands and Regions](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-filters-usage.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=412588028c7a79549120ca0aff658830) Monthly Reports filters with Usage selected ![Portfolio Energy Monthly Reports filter bar with Cost selected, Starred Buildings toggle, Buildings dropdown, date range, filter icon with active indicator, and second row including Building Type Currency set to US Dollar Countries States Brands and Regions](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-filters-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=55bd54cc9e40f546a6a4925db6c74db8) Monthly Reports filters with Cost selected and Currency dropdown > [!NOTE] > > Portfolio totals include every building that matches your active filters unless a widget states otherwise. ### Usage lens Select `Usage` on the toggle to view consumption charts. ![Portfolio Energy dashboard with Monthly Reports selected in the secondary menu, Usage toggle active, Starred Buildings on, Buildings dropdown, date range 06/22/2025 to 05/22/2026, and Monthly Usage bar chart from June 2025 through May 2026 with striped bar for March 2026](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-monthly-reports.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=bebf5ed1ab9449b9f1ce517df4c72bf2) Portfolio Energy Monthly Reports with Monthly Usage chart and report menu #### Monthly Usage The **Monthly Usage** chart totals portfolio consumption by calendar month for the selected period. * Teal bars show billed or calendarized usage in kWh * Striped bars indicate accrued or estimated months that lack final bills * Empty months mean no data posted for that period under your active filters Scroll the chart card when additional widgets sit below the fold. #### Usage per Service Type The **Usage per Service Type** chart stacks consumption by utility category across the same months. ![Usage per Service Type chart with grouped bars by month from June 2025 to May 2026 showing Electric, Natural Gas, District Steam, Lighting, and Electric on Site Solar in the legend with striped bars for March 2026](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-usage-per-service-type.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f3f7f02831e3fb2cfbf5aa2850bd02d3) Usage per Service Type grouped bar chart by month Legend colors map to service types such as **Electric**, **Natural Gas**, **District Steam**, and **Lighting**. Use this chart to see which fuels drive seasonal peaks. #### Usage per Building The **Usage per Building** chart shows a heatmap-style view of each building’s monthly usage. ![Usage per Building heatmap listing buildings such as Summit Ridge Plaza and Pacific Heights Tower with horizontal bars per month from June 2025 to April 2026 and a color legend from low teal to high red kWh values](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-usage-per-building.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9c158b197e4e9e705aefc44091ecec06) Usage per Building heatmap with color scale by kWh Bar color reflects relative usage for that month. Striped segments indicate accrued or incomplete data. Use this view to find outlier buildings before you open site-level dashboards. > [!WARNING] > > Striped bars are estimates or accruals. Confirm final bills before you use those months in compliance or savings reporting. ### Cost lens Select `Cost` on the toggle to view billed charges. Chart titles change to **Monthly Cost**, **Cost per Service Type**, and related cost views. ![Portfolio Energy Monthly Reports with Cost selected showing Monthly Cost bar chart by month from June 2025 to May 2026 with striped March 2026 bar and Cost per Service Type grouped chart with Electric Natural Gas District Steam and other service types](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-monthly-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=788bd290f550d736c48954bc106d9225) Portfolio Energy Monthly Reports with Monthly Cost and Cost per Service Type #### Monthly Cost The **Monthly Cost** chart totals portfolio utility spend by calendar month. Teal bars show billed cost. Striped bars indicate accrued or estimated months. #### Cost per Service Type The **Cost per Service Type** chart groups spend by utility category across the same months. Use it to see which fuels drive cost spikes in winter or summer peaks. #### Cost per Building and Top 10 Buildings Movers Scroll below the service-type chart to compare buildings. ![Cost per Building heatmap with buildings listed on the left and monthly cost bars from June 2025 to April 2026 with teal to red color scale, and Top 10 Buildings Movers chart below showing buildings with cost change patterns and red to teal legend for decreases and increases](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-cost-per-building.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f2856f1957afcc46488c1239dfc98997) Cost per Building heatmap and Top 10 Buildings Movers chart * **Cost per Building** — heatmap of monthly cost by property; color intensity reflects spend for that month * **Top 10 Buildings Movers** — buildings with the largest cost shifts over the selected period; legend shows decrease in red and increase in teal > [!TIP] > > Finance reviews often start with `Cost`, then open **Cost per Building** to find sites that need tariff or operations follow-up. ### Emission lens When your deployment includes `Emission` on the toggle, the same Monthly Reports layout shows carbon totals instead of usage or cost. Filters and building scope behave the same way. ## Annual Reports Select `Annual Reports` from the Energy secondary menu to compare buildings and years across the portfolio. The same filter rows as Monthly Reports apply, but the date control uses a **year range** (for example, 2021 to 2025) instead of month-by-month selection. ### Usage lens With `Usage` selected, the main card is **Connected Usage and EUI Analysis**. It pairs two bar charts that share the same building axis. ![Portfolio Energy Annual Reports with Usage selected showing Connected Usage and EUI Analysis with EUI bar chart in kWh per ft squared and Usage bar chart in kWh by building name, Sort by EUI set to 2025 Bar chart type, and pagination showing 1-24 of 24 buildings](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-reports-usage.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=e6a2aec07fe43567d122979de210768d) Annual Reports Usage view with Connected Usage and EUI Analysis Use the controls above the charts to change the view. * **Sort by** — order buildings by EUI, usage, or other metrics * **Year** — focus bars on a single calendar year such as 2025 * **Chart type** — switch between bar and other supported layouts * **Previous / Next** — page through buildings when the portfolio exceeds one page The top chart shows **EUI Analysis** in kWh/ft². The bottom chart shows **Usage Analysis** in kWh for the same buildings. Scroll below the paired charts for additional annual usage views. #### Usage per Service Type and Usage per Building ![Annual Usage per Service Type grouped bar chart by year 2021 to 2025 with Electric Natural Gas and District Steam legend, and Usage per Building heatmap with buildings on the left and years on the x-axis with teal to red color scale](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-usage-breakdown.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=aaf80edcf0db48a23d6fa73490603497) Annual Usage per Service Type and Usage per Building by year * **Usage per Service Type** — grouped bars by year for Electric, Natural Gas, District Steam, and other categories * **Usage per Building** — heatmap of each property’s annual usage; striped cells indicate accrued or incomplete data #### Energy Usage Intensity The **Energy Usage Intensity** heatmap compares EUI by building and year on a single color scale. ![Energy Usage Intensity heatmap with buildings listed on the left, years 2021 through 2025 on the x-axis, teal to red color gradient legend from 0.34 to 151.11 kWh per ft squared](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-eui.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=40959c8ce418a84443c3dd3548b7dd3e) Energy Usage Intensity heatmap by building and year Red cells highlight high-intensity outliers. Teal cells show lower intensity relative to the portfolio range in the legend. ### Cost lens Select `Cost` to open **Annual Cost and Intensity Analysis** with the same paired-bar layout, sorted and filtered for spend. ![Portfolio Energy Annual Reports with Cost selected showing Annual Cost and Intensity Analysis with intensity chart in dollars per ft squared and cost chart in US dollars by building, Sort by Cost per building year 2025 Bar chart, Currency US Dollar in filter row](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-reports-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=3dbe7f6db2b3ac7a4285548fc796b656) Annual Reports Cost view with Annual Cost and Intensity Analysis The top chart shows intensity in **\$/ft²**. The bottom chart shows total **cost** in your selected currency. Use **Currency** in the second filter row when `Cost` is active. #### Annual Cost per Service Type and Annual Cost per Building ![Annual Cost per Service Type bar chart by year 2021 to 2025 with Electric dominant in yellow, and Annual Cost per Building heatmap with teal and red segments by building and year](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-cost-breakdown.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=3e11967f85350249a49cbfa22e807b10) Annual Cost per Service Type and Annual Cost per Building by year Hover a building cell to see cost detail. The tooltip splits **Provider** (solid) and **Accrued** (striped) amounts. ![Tooltip for Meadowbrook Super Center Year 2025 showing Total Cost 1835262.88 with Provider 1832216.49 in solid red and Accrued 3046.39 in striped red](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-cost-tooltip.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=151dd5f56a1269bc9f873a10bdaf3f22) Annual cost tooltip showing Provider and Accrued split for a building #### Rolling Cost The **Rolling Cost** heatmap shows cost intensity in **\$/ft²** by building and year. ![Rolling Cost heatmap with buildings on the left, years 2021 to 2025, teal bars for most cells, red rows for high-cost buildings, and legend from 0.01 to 18.31 dollars per ft squared](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-annual-rolling-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=45013eabc67a51af75e5410392241dc4) Rolling Cost heatmap by building and year Striped segments in a cell indicate accrued portions of annual cost, consistent with Monthly Reports styling. ## Target Select `Target` from the Energy secondary menu to compare portfolio actual performance against a reduction target and baseline. Create and manage targets from the portfolio `Target` sidebar item or on [Portfolio targets](/products/energ/analytics/portfolio-targets). ### Controls * **Breakdown by Service Type** — split charts by utility category when enabled * **Unit** — choose the energy unit for charts, such as **kBTU** * **Target** — select which portfolio target to display, such as a named 2050 reduction goal ![Portfolio Energy Target page showing Target Energy Comparison line chart with Actual Target and Baseline lines from December 2024 to March 2026, Delta from Target red bar chart, and Delta from Baseline teal bar chart, with Breakdown by Service Type toggle and kBTU and target dropdowns](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-target.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=6d0be9a08bb864523703a87ae59bc4da) Portfolio Energy Target view with comparison and delta charts ### Charts Three charts stack on the Target page. | Chart | What it shows | | - | - | | **Target Energy Comparison** | **Actual**, **Target**, and **Baseline** trends over time | | **Delta from Target** | Monthly gap between actual use and the target trajectory | | **Delta from Baseline** | Monthly difference between actual use and the baseline period | Red bars in **Delta from Target** grow when actual use stays flat while the target line falls. Teal bars in **Delta from Baseline** show whether you are above or below the historical baseline. ## Data Table Select `Data Table` from the Energy secondary menu to audit line-level billing and calendarized records across the portfolio. ### Filters and export The Data Table uses a filter layout similar to Monthly Reports, with a few additions. * **Starred Buildings** and **Buildings** — limit rows to favorites or selected properties * **Building Type**, **Countries**, **States**, **Brands**, and **Regions** — portfolio scope filters * **Period Type** — control how periods are grouped in the grid * **Service tags** — active chips such as `Full Service` and `Delivery` filter service categories * **Date range** — restrict rows to a start and end date, such as 05/22/2025 – 05/22/2026 * **Export** — download the filtered table for offline analysis ### Billing Period and Calendarized tabs Switch between two views of the same underlying data. ![Portfolio Energy Data Table with Billing Period tab selected showing filters for Building Type Countries States Brands Regions Period Type Full Service and Delivery chips date range Export button, and table columns for Meter Building Name Service Type Charges Usage and pagination 1-50 of 682](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-data-table-billing.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=73b997195d5527cfd860a27b4a38ecd6) Data Table Billing Period tab with meter and building columns ![Portfolio Energy Data Table with Calendarized tab selected showing similar filter row and table with Meter Building Name State Service Type Charges Usage columns and pagination 1-50 of 803](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-energy-data-table-calendarized.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=2e801028c354a4cd34d022f3c822655f) Data Table Calendarized tab with calendarized usage rows | Tab | Purpose | | - | - | | **Billing Period** | One row per billing period as utilities report it | | **Calendarized** | Usage and cost spread across calendar months for consistent reporting | ### Table columns Sort any column with the header arrows. Scroll horizontally to reach all fields, including meter, building, service type, charges, usage, `Estimated`, and `Data Origin`. For every column definition, see [data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). > [!NOTE] > > A row with **Estimated** set to `true` and **Data Origin** of `System Accrual` closes a gap until a final bill arrives. Confirm accrual rows before you use them in compliance or year-end reporting. ### Pagination The footer shows page numbers and **Lines per page** (for example, 1–50 of 682 on Billing Period). Use the arrows to move through large portfolios without loading every row at once. ## Export Energy dashboard data Export spreadsheet-ready data from any Energy dashboard chart or page. The file matches the building filter, date range, and metric toggle active when you download. **1. Finalize filters** Set the building filter, date range, and metric toggle to match the data you want to export. **2. Run the export** Use the download control on the page or chart. Save the Excel file when your browser prompts you. > [!TIP] > > Exports reflect the filters and date range active when you start the export. Finalize filters before you download. > [!NOTE] > > Export does not replace [Report Builder](/products/energ/finance/reporting) for custom layouts. PDF or image-only export is not included. ## Next steps > [card] [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water) > > Review water consumption totals and trends across the portfolio. > [card] [Portfolio Waste dashboard](/products/energ/analytics/portfolio-dashboards-waste) > > Track quantities, diversion rate, and capture rate portfolio-wide. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Rank buildings with EUI, WUI, and GHG before you open dashboard charts. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Create portfolio reduction targets that appear in the Energy Target view. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Open building-level Monthly Reports with year-over-year comparison charts. # Portfolio Waste dashboard Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-dashboards-waste Review portfolio-level waste quantities, costs, diversion rate, and capture rate The portfolio **Waste** dashboard aggregates waste quantities, costs, and diversion performance across every building in KODE OS. In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), open `Dashboards` in the left sidebar, then select `Waste`. The page header reads **Waste** with the subtitle *Review your building waste usage & reporting.* Unlike Energy and Water, the Waste dashboard uses a single view without a secondary report menu. > [!NOTE] > > Open a building and select **Dashboards** > **Waste** for site-level KPIs, charts, and pickup entry on the [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste). ## Open the Waste dashboard **1. Open Dashboards** In the portfolio left sidebar, click `Dashboards`, then click `Waste`. **2. Set scope and units** Use **Select Buildings** to limit which properties appear. Choose a unit such as **Pounds** from the unit dropdown. Set the **date range** for the reporting window. **3. Read summary KPIs** Scan the metric cards for total waste, diversion, capture rate, and cost before you review charts below. ## Controls * **Add Waste Data** — enter or import waste readings when your workflow supports portfolio-level entry * **Select Buildings** — filter the dashboard to specific properties * **Unit** — display quantities in pounds, kilograms, or other supported units * **Date range** — define the period for KPIs and charts, such as 01/01/2026 – 05/22/2026 ![Portfolio Waste dashboard showing Add Waste Data button Select Buildings dropdown Pounds unit date range, KPI cards for Total Waste Diverted Waste Diversion Rate Data Capture Rate Total Cost and Cost Per Unit, Monthly Waste Quantity stacked chart for Composted and Disposed, and Monthly Waste Cost bar chart](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-waste-overview.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=ef82c189169323991986d07d4653ee88) Portfolio Waste dashboard with KPI cards and monthly quantity and cost charts ## Summary metrics Six KPI cards appear below the header. | Metric | What it shows | | - | - | | **Total Waste** | Combined waste quantity for the selected scope and period | | **Diverted Waste** | Quantity routed away from landfill | | Diversion Rate (Share of total waste routed away from landfill.) | Percentage of total waste diverted | | Data Capture Rate (How completely reported waste covers the streams you expect to track.) | How completely waste streams are reported relative to expectations | | **Total Cost** | Waste management spend for the period | | **Cost Per Unit** | Average cost per unit of waste, such as \$/lbm | ## Monthly waste charts ### Monthly Waste Quantity The **Monthly Waste Quantity** chart stacks waste by disposal method each month. * **Composted** — material sent to composting (typically shown in green) * **Disposed** — material sent to landfill or disposal (typically shown in brown) Use this chart to see whether diversion improves month over month. ### Monthly Waste Cost The **Monthly Waste Cost** chart shows total waste management spend by month. Compare it with quantity trends to spot cost-per-unit changes. ## Diversion and composition Scroll below the monthly charts for portfolio breakdowns. ![Diversion and Data Capture Rate bar chart by building, Waste Composition by Stream bar chart for Cardboard and Plastics, and Waste Composition by Disposal Method bar chart for Composted and Disposed](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-waste-composition.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=4b9b5a48e8e7e75a836cf9b121dd136e) Diversion rate and waste composition by stream and disposal method ### Diversion and Data Capture Rate Compare **Diversion Rate** bars (and **Data Capture Rate** when shown) across buildings or portfolio totals. ### Waste Composition by Stream See how much waste falls into each material stream, such as cardboard or mixed plastics. ### Waste Composition by Disposal Method See how volume splits between **Composted**, **Disposed**, and other configured methods. ## Top buildings ![Horizontal bar charts showing Top Buildings by Waste Quantity and Top Buildings by Waste Cost with One Financial Plaza as the top entry in each](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-waste-top-buildings.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=99e61c2c0eec069c896f48e9d3994941) Top Buildings by Waste Quantity and Top Buildings by Waste Cost * **Top Buildings by Waste Quantity** — properties generating the most waste * **Top Buildings by Waste Cost** — properties with the highest waste management costs Use these rankings to prioritize audits, stream setup, or capital projects. > [!NOTE] > > Waste data often depends on manual entry at the building level. Confirm waste streams are configured on the [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste#create-waste-streams) for sites you include in portfolio totals. ## Add waste data at portfolio level Click **Add Waste Data** when you need to record pickups or adjustments that apply to the selected building scope. For stream setup, use **Create Meter** on the [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste#create-waste-streams). ## Next steps > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Review energy usage and emissions for the same portfolio scope. > [card] [Portfolio Water dashboard](/products/energ/analytics/portfolio-dashboards-water) > > Review water consumption alongside waste reporting cycles. > [card] [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) > > Review building-level KPIs and composition charts. > [card] [Create waste streams](/products/energ/analytics/building-dashboards-waste#create-waste-streams) > > Configure waste streams and data entry at the building level. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Return to portfolio rankings and building detail panels from Home. # Portfolio Water dashboard Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-dashboards-water Review portfolio-level water usage, cost, and intensity across all buildings The portfolio **Water** dashboard aggregates water consumption and intensity across every building in KODE OS. In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), open `Dashboards` in the left sidebar, then select `Water`. The page header reads **Water** with the subtitle *Water Use, Efficiency, and Performance Overview.* ## Water report menu After you select `Water`, use the secondary menu to switch report types. | Report | What it shows | | - | - | | `Monthly Reports` | Portfolio monthly water usage and cost by month, service type, and building | | `Annual Reports` | Annual water usage and cost by building, service type, and water use intensity (Water Use Intensity: water consumption normalized by floor area.) | | `Target` | Actual, target, and baseline water comparison charts for a selected target | | `Data Table` | Sortable water billing and calendarized line items with export | > [!NOTE] > > The portfolio Water menu does not include building-only items such as `Comparison` or `Data Quality`. Open a building to access those reports on the [Building Water dashboard](/products/energ/analytics/building-dashboards-water). `Monthly Reports` is the default view when you open `Water`. ## Monthly Reports ### Controls The control area matches the [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) layout. **Top row** * **Usage / Cost** — switches all charts between consumption in liters and billed cost * **Starred Buildings** — limit results to favorited sites * **Buildings** — select or deselect individual buildings * **Date range** — pick start and end months, such as 06/22/2025 – 05/22/2026 * **Filter** — open advanced filters **Second row** * **Building Type**, **Countries**, **States**, **Brands**, and **Regions** * **Currency** — appears when `Cost` is selected (for example, US Dollar) > [!NOTE] > > Portfolio water totals include every building that matches your active filters unless a widget states otherwise. ### Usage lens Select `Usage` to view consumption charts in liters (L). ![Portfolio Water Monthly Reports with Usage selected showing Monthly Usage bar chart in liters from June 2025 to March 2026 with striped March bar, Usage per Service Type chart below, filter row with Building Type Countries States Brands Regions, and secondary menu with Monthly Reports selected](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-monthly-usage.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=b0e86ab20b652244bb28c5e49ac3d7ed) Portfolio Water Monthly Reports with Monthly Usage and Usage per Service Type #### Monthly Usage The **Monthly Usage** chart totals portfolio water consumption by calendar month. * Teal bars show billed or calendarized volume in liters * Striped bars indicate accrued or estimated months * Empty months mean no data for that period under your active filters #### Usage per Service Type The **Usage per Service Type** chart shows water volume by category across the same months. The legend typically maps to the **Water** service type for portfolio water dashboards. #### Usage per Building and Top 10 Buildings Movers Scroll below the service-type chart for building-level views. ![Usage per Building heatmap with building names on the left and months June 2025 to March 2026 with teal to red legend in liters, and Top 10 Buildings Movers chart below with teal to red scale for negative and positive usage change](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-usage-per-building.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=49a06943e0f0051f0f395dfabecf0980) Usage per Building heatmap and Top 10 Buildings Movers for water * **Usage per Building** — heatmap of monthly water use by property * **Top 10 Buildings Movers** — buildings with the largest usage shifts; legend shows decrease in teal and increase in red > [!WARNING] > > Striped cells are estimates or accruals. Confirm final bills before you use those months in reporting. ### Cost lens Select `Cost` to view water utility spend. ![Portfolio Water Monthly Reports with Cost selected showing Monthly Cost bar chart in US dollars, Cost per Service Type chart with Water legend, Currency US Dollar in filter row, and date range 06/22/2025 to 05/22/2026](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-monthly-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=67c3dc16c564c4786dd60838aff46abb) Portfolio Water Monthly Reports with Monthly Cost and Cost per Service Type #### Monthly Cost The **Monthly Cost** chart totals portfolio water spend by month. Striped bars indicate accrued or incomplete billing periods. #### Cost per Service Type The **Cost per Service Type** chart groups water cost by service category for each month. #### Cost per Building and Top 10 Buildings Movers ![Cost per Building heatmap with teal to red cost scale by month and Top 10 Buildings Movers chart with legend from negative to positive dollar change](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-cost-per-building.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=4434509cb17b46af3536ad7b030ef487) Cost per Building heatmap and Top 10 Buildings Movers for water cost > [!TIP] > > Pair the Water dashboard with [Portfolio Home](/products/energ/analytics/benchmarking) when you rank buildings by WUI for the same date range. ## Annual Reports Select `Annual Reports` from the Water secondary menu to compare buildings and years. Use a **year range** (for example, 2021 to 2025) instead of the month picker on Monthly Reports. The filter rows match Monthly Reports. ### Usage lens With `Usage` selected, the main card is **Connected Usage and EUI Analysis** with paired bar charts. ![Portfolio Water Annual Reports with Usage selected showing EUI Analysis in L per ft squared and Usage Analysis in liters by building name, Sort by EUI year 2025 Bar chart, pagination 1-21 of 21 buildings](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-reports-usage.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=60a93f910ff0da1fc9ba0fef22f1a73e) Water Annual Reports Usage view with Connected Usage and EUI Analysis Use the controls above the charts to change sort order, focus year, and chart type. Use **Previous** and **Next** when the portfolio spans multiple pages. * **EUI Analysis** — water use intensity in L/ft² by building * **Usage Analysis** — total water volume in liters for the same buildings #### Usage per Service Type and Usage per Building ![Annual Usage per Service Type bar chart by year 2021 to 2025 with Water legend in blue, and Usage per Building heatmap with teal to red legend in liters](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-usage-breakdown.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=4e6bf980d78f79dac11b463b4bd5fe45) Annual Usage per Service Type and Usage per Building for water * **Usage per Service Type** — annual water volume by year; legend maps to **Water** * **Usage per Building** — heatmap of each property’s annual usage #### Water Usage Intensity ![Water Usage Intensity heatmap with buildings on the left, years 2021 to 2025, red rows for high intensity buildings and teal rows for lower intensity, legend from 61.02 to 184.49 L per ft squared](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-wui.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=7218a0afc3c60274e5161f6e00fee173) Water Usage Intensity heatmap by building and year The **Water Usage Intensity** heatmap highlights outliers in red and lower-intensity sites in teal. ### Cost lens Select `Cost` for **Annual Cost and Intensity Analysis**. ![Portfolio Water Annual Reports with Cost selected showing intensity in dollars per ft squared and cost in dollars by building, Currency US Dollar filter, year range 2021 to 2025](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-reports-cost.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=cbe91e3163aa04365a6a6788e3338bd0) Water Annual Reports Cost view with intensity and cost bar charts The top chart shows **\$/ft²**. The bottom chart shows total water **cost** in the selected currency. #### Annual Cost per Service Type ![Annual Cost per Service Type bar chart from 2021 to 2025 with blue Water bars near 500000 dollars](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-cost-service-type.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=345f8985bbc44a8de0921e1f52c8e52a) Annual Cost per Service Type for water by year #### Annual Cost per Building and Rolling Cost ![Annual Cost per Building heatmap with teal to red scale by year and Rolling Cost heatmap below with similar layout for water cost intensity](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-annual-cost-breakdown.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=588366c0ede7bb772da08abc169cc052) Annual Cost per Building and Rolling Cost heatmaps for water * **Annual Cost per Building** — annual spend by property and year * **Rolling Cost** — cost intensity in **\$/ft²** across the year range ## Target Select `Target` from the Water secondary menu to compare portfolio actual water use against a reduction target and baseline. Create targets from the portfolio `Target` sidebar or on [Portfolio targets](/products/energ/analytics/portfolio-targets). ### Controls * **Breakdown by Service Type** — split charts by category when enabled * **Unit** — choose the volume unit for charts, such as **Cubic Meter** * **Target** — select which portfolio water target to display, such as a named 2040 reduction goal ![Portfolio Water Target page showing Target Water Comparison line chart with Actual Target and Baseline in cubic meters from December 2022 to February 2026, Delta from Target bar chart with teal and red bars, and Delta from Baseline teal bar chart](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-target.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=5cf921deb4d2025641d8eb5955ddfe14) Portfolio Water Target view with comparison and delta charts ### Charts | Chart | What it shows | | - | - | | **Target Water Comparison** | **Actual**, **Target**, and **Baseline** trends over time | | **Delta from Target** | Monthly gap between actual use and the target trajectory | | **Delta from Baseline** | Monthly difference between actual use and the baseline period | Teal bars below zero in **Delta from Target** mean actual use fell below the target. Red bars above zero mean usage exceeded the target for that month. ## Data Table Select `Data Table` from the Water secondary menu to audit line-level water billing and calendarized records. ### Filters and export * **Starred Buildings** and **Buildings** — limit rows to favorites or selected properties * **Building Type**, **Countries**, **States**, **Brands**, and **Regions** — portfolio scope filters * **Period Type** — control how periods are grouped * **Service tags** — active chips such as `Full Service` and `Delivery` * **Date range** — restrict rows, such as 05/22/2025 – 05/22/2026 * **Export** — download the filtered table Filter **Service Type** to **Water** when you need only water meters. The table may include other service types depending on your filter settings. ### Billing Period and Calendarized tabs ![Portfolio Water Data Table with Billing Period tab selected showing water meter rows with Building Name State Service Type Water Charges Usage in gal Estimated column and filters for date range and Export](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-data-table-billing.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=54f25de9f0c56576108137485a6e4ed0) Water Data Table Billing Period tab ![Portfolio Water Data Table with Calendarized tab selected showing meter building service type usage and cost columns with pagination 1-50 of 803](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-water-data-table-calendarized.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f83d57685113cb6a95cf3c99d096da39) Water Data Table Calendarized tab | Tab | Purpose | | - | - | | **Billing Period** | One row per billing period as utilities report it | | **Calendarized** | Usage and cost spread across calendar months | ### Table columns Sort any column with the header arrows. Scroll horizontally for all fields, including meter, building, service type, charges, usage, `Estimated`, and `Data Origin`. For every column definition, see [data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). > [!NOTE] > > Confirm **Service Type** is **Water** before you report portfolio water totals from Data Table exports. Mixed-service exports can include electric or other meters when filters are broad. ### Pagination The footer shows page count and **Lines per page** (for example, 1–50 of 210 on Billing Period). Use the arrows to page through large portfolios. ## Export Water dashboard data **1. Finalize filters** Set the building filter, date range, and Usage or Cost toggle to match the data you want to export. **2. Run the export** Use the export action on Data Table or the dashboard export control when available. > [!WARNING] > > Exports reflect the filters and date range active when you start the export. ## Next steps > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Review energy usage, cost, and emissions for the same portfolio scope. > [card] [Portfolio Waste dashboard](/products/energ/analytics/portfolio-dashboards-waste) > > Track waste quantities, diversion, and capture rate portfolio-wide. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Compare WUI rankings on the Home page before you open water charts. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Create portfolio water reduction targets for the Target view. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Connect water meters and utility data that feed portfolio water totals. # Portfolio data sources Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-data-sources Connect and manage data sources across your portfolio in EnerG Connect utility and meter feeds at portfolio scope in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Click `Data Sources` in the left sidebar, then open **Overview** or a connector page. Building-level data source settings apply after you select a site. See [Building data sources](/products/energ/buildings/data-sources) in the building view. For how feeds and meters organize EnerG data, see [Data sources and meters](/products/energ/concepts/data-and-meters). ## Supported ingestion methods | Method | Purpose | | - | - | | [Arcadia](/products/energ/data-sources/arcadia) | Automate utility data collection through credential-based connections | | [Portfolio Manager](/products/energ/data-sources/portfolio-manager) | Sync ENERGY STAR Portfolio Manager properties, meters, usage, and scores | | [CSV uploads](/products/energ/data-sources/csv-uploads) | Load historical totals from spreadsheets | | [Manual entry](/products/energ/data-sources/manual-entry) | Create meters and enter readings without an automated feed | | [KODE OS data source](/products/energ/data-sources/kode-os-data-source) | Bring interval meters from KODE OS for analytics and M\&V | ## Next steps > [card] [Portfolio meters](/products/energ/analytics/portfolio-meters) > > Assign meters to buildings after you connect a data source. > [card] [Building data sources](/products/energ/buildings/data-sources) > > Review data sources scoped to one building. > [card] [Arcadia](/products/energ/data-sources/arcadia) > > Set up Arcadia credentials and meter mapping. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Resolve connection and completeness alerts. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how utility bills and interval reads feed EnerG. # Portfolio emissions benchmarking Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-benchmarking Compare emissions performance by building across your portfolio in EnerG Compare emissions performance across buildings in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Expand `Emissions` in the left sidebar and select `Benchmarking` to rank sites by total emissions. For scopes and accounting methods, see [Emissions accounting](/products/energ/concepts/emissions-accounting). ## Navigate to Benchmarking Click `Emissions` > `Benchmarking` in the portfolio left sidebar. ### Filter the view Use the filter row to scope the chart and tables. | Filter | Purpose | | - | - | | **Region** | Limit results to a region | | **Sub-region** | Narrow further after you select a region | | **Select Building** | Focus on one or more buildings | | **Year** | Calendar year for emissions comparison (for example, `2026`) | ## Emissions by Building chart The **Emissions by Building** chart ranks sites by total emissions. Stacked bars show Scope 1 (Direct greenhouse gas emissions from sources you own or control, such as on-site combustion, fleet fuel, and refrigerant loss.) and Scope 2 (Indirect greenhouse gas emissions from purchased energy such as electricity and district steam.) contributions. ![Benchmarking page with Emissions by Building stacked bar chart showing Scope 1 and Scope 2 by building, Location Based dropdown, Previous and Next pagination, and Showing 1-20 of 24 buildings](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-benchmarking-chart.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=94ad36367390c25a84bc49cda1396d2c) Emissions by Building stacked bar chart with Location Based view | Control | Purpose | | - | - | | **Location Based / Market Based** | Switch the accounting method for Scope 2 | | **Previous / Next** | Page through buildings when the portfolio exceeds one page | | **Items per page** | Number of buildings shown per chart page (for example, `20`) | Buildings sort from highest to lowest total emissions on the active page. ## Building Emissions table Below the chart, the **Emissions** table lists each building with scope and service-type columns. Click a **Building** name to open that site. Scroll horizontally to view all column groups. Column headers support sorting. ![Emissions table with Building column and Scope 1 Natural Gas and Scope 1 Total and Scope 2 District Steam Electric Location Based and Market Based columns for buildings such as Beacon Hill Complex and Capitol View Tower](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-benchmarking-emissions-table.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=b30a16bfb74d560d8540175a6f0791c6) Emissions table with Scope 1 and Scope 2 columns by building For the Scope 1, Scope 2, Additional Services, REC, and Totals column groups in this table, see [scope breakdown columns](/products/energ/reference/emissions-reference#scope-columns). ## Building Consumptions table The **Consumptions** table shows activity data that supports emissions calculations for each building. Its structure matches the emissions table with consumption units (kWh, L) instead of kg CO₂e. ![Consumptions table with Building column and Scope 1 Natural Gas and Scope 1 Total and Scope 2 District Steam Electric and Scope 2 Total columns for multiple buildings](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-benchmarking-consumptions-table.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=d9ee1582d3367e856977951de242212c) Consumptions table with Scope 1 and Scope 2 totals by building Scroll horizontally in EnerG to review District Steam, Electric, onsite solar, water, and REC columns for each building. > [!TIP] > > Compare the **Emissions** and **Consumptions** tables for the same filter set when you explain why a building ranks high on the chart. ## Next steps > [card] [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review portfolio-wide scope breakdown and offset charts. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up the scope column groups behind these tables. > [card] [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) > > Allocate REC and volume-based contract volume to buildings. > [card] [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions) > > Manage vehicles and mileage for Scope 1 mobile combustion. > [card] [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions) > > Track refrigerant loss for Scope 1 fugitive reporting. > [card] [Report Builder](/products/energ/finance/reporting) > > Export emissions metrics with other portfolio data. # Volume contracts Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-contracts Create, allocate, and retire renewable energy contracts and RECs in EnerG Create, allocate, and retire volume-based emission contracts in EnerG. Expand **Emissions** in the left sidebar and open **Contracts** to record renewable energy certificates (RECs) (Renewable energy certificate: a tradable attribute representing renewable generation that can be allocated and retired.), offsets, and other instruments that reduce or attribute emissions. Reach this page from the [portfolio view](/products/energ/get-started/navigation#portfolio-view) or the [building view](/products/energ/get-started/navigation#building-view) after you select a site. For how instruments affect emissions, see [RECs and offsets](/products/energ/concepts/emissions-accounting#recs-and-covered-load). ## Navigate to Volume Contracts Click `Emissions` > `Contracts` in the portfolio left sidebar. ![Volume Contracts page with Search field, Filter button, Create Contract button, and table showing contract name with Allocate action, contract type, procurement method, status, coverage, and total volume for REC contracts such as MISO\_REC\_Offset\_Companion\_2025](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-emissions-volume-contracts.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=ca29f29da2a4991b42ba20e4f82344da) Volume Contracts page with search, filter, and contracts table Click `+ Create Contract` in the top right to add a new agreement. Use **Search** to find contracts by name and click `Filter` to narrow the list by status, type, or reporting year. For the columns in the contracts table, see [volume contract fields](/products/energ/reference/emissions-reference#contract-fields). ## Allocate contract volume Click **Allocate** on a contract row to distribute **Total Volume** across buildings or time periods. When **Allocated** equals **Total Volume** and **Remaining** is `0 kWh`, the contract is fully assigned. ## Retire a contract Each contract row includes actions on the right side of the table, after **Document URL**. | Action | Purpose | | - | - | | **Retire** | Retire environmental attributes so they count toward offsets and market-based reporting | | **Delete** | Remove the contract from the library | ![Volume contract table row showing Pending retirement status badge, Retire tooltip on the retire icon, and delete trash icon in the row actions column](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-contract-retire.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1b07ec51fd256758270f6f25f27fee24) Retire action on a volume contract with Pending retirement status Contracts with **Pending retirement** in the **Retirement Status** column are not yet retired. Click **Retire** to complete retirement. After retirement, **Retirement Status** updates and REC volume appears in offset charts on [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). > [!NOTE] > > Confirm **Retirement Status** before you report market-based Scope 2 (Indirect greenhouse gas emissions from purchased energy such as electricity and district steam.) emissions. Retired REC volume rolls into offset and renewable charts on [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ## Create a contract Click `+ Create Contract` to open the **Create Contract** panel on the right. The panel subtitle reads *Add a renewable energy instrument.* ![Create Contract side panel with Contract Name Market Country Region State Contract Type Procurement method Energy Source Total Volume and Unit fields, and Close and Submit buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-create-contract.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=00180e3cd3c610c4ca28953af537332b) Create Contract panel with Contract Details fields **1. Enter contract details** Fill in **Contract Name**, **Market**, **Country**, **Contract Type**, **Energy Source**, **Total Volume**, and **Unit**. Add **Region / State** and **Procurement method** when they apply. **Country** activates after you choose **Market**, and **Region / State** activates after you choose **Country**. **2. Set factors and reporting years** Enter **Vintage Year** and **Applicable Reporting Year**. Adjust **Emission Factor** and **Emission Factor Unit** when the contract includes a linked factor. **3. Add dates and documentation** Set **Contract Start** and **Contract End** for the agreement window. Enter **Registry / Counterparty**, **Serial Numbers**, **Document URL**, and **Notes** when you have audit evidence. **4. Submit the contract** Click `Submit` to save the contract. Click `Close` to exit without saving. For the full list of contract fields, see [volume contract fields](/products/energ/reference/emissions-reference#contract-fields). After you create the contract, click **Allocate** on the row to assign volume to buildings. Use **Retire** when **Retirement Status** is `Pending retirement` and you are ready to count attributes in offset reporting. > [!TIP] > > Fully allocate active REC contracts so **Remaining** reaches zero before period close. Unallocated volume does not attribute renewable energy to buildings in benchmarking or overview rollups. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand RECs, offsets, and market-based Scope 2. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up the full volume contract field list. > [card] [Building emissions overview](/products/energ/buildings/emissions-overview) > > Review GHG charts and scope tables for one building. > [card] [Portfolio emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review offset breakdown and renewable contract rollups. > [card] [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors) > > Manage factors used alongside contract attributes. > [card] [Emissions benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking) > > Compare building emissions after contracts are allocated. # Emission factors library Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-emission-factors Create, publish, and manage emission factor sets for carbon calculations in EnerG Manage the emission factors (A value that converts activity data into greenhouse gas emissions.) that drive carbon calculations in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Expand `Emissions` in the left sidebar and open `Emission Factors` to create, publish, and edit factor sets. For how factors convert activity into carbon, see [Emission factors](/products/energ/concepts/emissions-accounting#emission-factors). ## Navigate to Emission Factors Click `Emissions` > `Emission Factors` in the portfolio left sidebar. ![Emissions Factor Library page with Search field, Filter button, Create Factor button, and table with Name Status Methodology Scope Service Type Country Region Grid Source and Created columns showing factors such as AIB EU Residual Mix and California Market Based](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-factor-library.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=2002bdd664ed70e4d7ee5cd1b9bfca86) Emissions Factor Library with search, filters, and the factors table Click `+ Create Factor` to open the **Create Factor Set** panel. Review the library table to check existing factors before you add or edit entries. For the column definitions in this table, see [emission factor fields](/products/energ/reference/emissions-reference#emission-factor-fields). ## Search and filter factors Use **Search** to find factors by name. Click `Filter` to show additional filters. ![Search field with Filter button and dropdown filters for Status Service Type Country Methodology and Effective date range with calendar icon](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-factor-filters.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=8976494464048078df2a39811f143232) Emission factor filters for Status, Service Type, Country, Methodology, and effective date range | Filter | Purpose | | - | - | | **Status** | Show `Active`, `Draft`, or other statuses | | **Service Type** | Filter by commodity such as `Electric` or `Coal Anthracite` | | **Country** | Limit factors to one country | | **Methodology** | Filter by approach such as `Market Based` | | **Effective date range** | Show factors effective within a date window | Use pagination at the bottom to move through large libraries (for example, `1–50 of 139`). ## Publish or edit a factor Each factor row includes actions on the right side of the table. | Action | Purpose | | - | - | | **Publish Draft** | Activate a factor in `Draft` status so it applies to carbon calculations | | **Edit** | Open the factor set to change details, documentation, or geography | | **Delete** | Remove the factor from the library | ![Emission factor table row actions showing Publish Draft tooltip on the publish icon, edit pencil icon, and delete trash icon for a draft factor dated 05/05/2026](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-factor-publish-draft.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=c900db72998971b65515dcd07bf82d7f) Publish Draft action on a draft emission factor row Factors with **Active** status are already published. Click **Publish Draft** on draft rows (such as `California Market Based`) before you rely on them in emissions reports. ## Create a factor set Click `+ Create Factor` to open the **Create Factor Set** panel on the right. ![Create Factor Set side panel with Factor Name Description Organization Default checkbox Service Type Methodology and Scopes fields, Documentation section with Source Reference Provenance and Documentation Notes, and Close Add Factor Version and Save buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-create-factor-set.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=151d16b8b0b47d3ac944f16f6ec14c62) Create Factor Set panel with Basic Information and Documentation sections **1. Enter basic information** Fill in **Factor Name**, **Service Type**, and **Scopes** (for example, Scope 2 (Indirect greenhouse gas emissions from purchased energy such as electricity and district steam.)). Add **Description**, **Methodology**, and **Organization Default** when needed. **2. Add documentation** Enter **Provenance** and optional **Source Reference** and **Documentation Notes**. **3. Configure geography or buildings** Choose **Apply to Building** or **Apply geography wise**. When you apply geography wise, set **Country**, then **Region** and **Grid Code**, which activate after you select a country. **4. Save the factor set** Click `Add Factor Version` to add a version before you save, or click `Save` to store the factor set. Click `Close` to exit without saving. For the full list of factor set fields, see [emission factor fields](/products/energ/reference/emissions-reference#emission-factor-fields). > [!NOTE] > > Factors in `Draft` status do not affect production calculations until you activate them. Review draft entries before you rely on them in [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) or [Benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking). ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand how factors convert activity into carbon. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up the full emission factor field list. > [card] [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > See how factors roll up in portfolio emissions charts. > [card] [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) > > Manage REC and volume-based emission contracts. > [card] [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions) > > Manage vehicles and mileage for Scope 1 mobile combustion. > [card] [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions) > > Track refrigerant loss for Scope 1 fugitive reporting. # Fleet emissions Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-fleet-emissions Register vehicles and log mileage for Scope 1 mobile combustion in EnerG Register company vehicles and log mileage for Scope 1 (Direct greenhouse gas emissions from sources you own or control, such as on-site combustion, fleet fuel, and refrigerant loss.) mobile combustion reporting in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Expand `Emissions` in the left sidebar and open `Fleet Emissions`. Fleet data rolls into portfolio Scope 1 totals on [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) and [Benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking). For the accounting model, see [GHG scopes](/products/energ/concepts/emissions-accounting#ghg-scopes). ## Navigate to Fleet Emissions Click `Emissions` > `Fleet Emissions` in the portfolio left sidebar. ![Fleet Emissions page showing Total fleet emissions card at 108.74 kg CO2e, Vehicles and Mileage records tabs, Search and Fuel Type filter, and vehicles table with Delivery Truck 01 diesel light truck row](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-fleet-emissions.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=cbdb09b6c4a7119725a1bd2ed45c3bb8) Fleet Emissions page with total emissions summary, Vehicles tab, and fleet table The **Total fleet emissions** card shows portfolio-wide mobile combustion in **kg CO₂e** for the active filters. Two tabs organize fleet data: | Tab | Purpose | | - | - | | **Vehicles** | Register fleet assets, fuel type, and annual distance or emissions | | **Mileage records** | Record mileage and fuel activity that drives Scope 1 calculations | Define each asset on **Vehicles** first, then log activity on **Mileage records**. For the vehicle and mileage record fields, see [fleet fields](/products/energ/reference/emissions-reference#fleet-fields). ## Create a vehicle On the **Vehicles** tab, click `+ Create Vehicle` to open the **Create Vehicle** panel on the right. The panel subtitle reads *Add a vehicle to your fleet.* ![Create Vehicle side panel with Vehicle Name Fuel Type Vehicle Type Year Make Model License Plate VIN and Notes fields, and Close and Create buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-create-vehicle.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=c900513577b4185561a51f02c964853d) Create Vehicle panel with Vehicle Details fields **1. Enter vehicle details** Fill in **Vehicle Name** and **Fuel Type**. Add **Vehicle Type**, **Year**, **Make**, **Model**, **License Plate**, and **VIN** when you have them. **2. Add notes** Enter optional **Notes** for fleet managers or auditors. **3. Create the vehicle** Click `Create` to save the vehicle. Click `Close` to exit without saving. To find vehicles on the tab, use **Search** by name or plate, and use the **Fuel Type** dropdown to limit the table to one fuel category. Use the **Edit** and **Delete** actions in the **Actions** column to update or remove a vehicle. After you create a vehicle, add mileage records on the **Mileage records** tab. See [Add a fleet mileage record](#add-a-fleet-mileage-record). ## Mileage records tab Open the **Mileage records** tab to review logged trips and fuel use. ![Fleet Emissions Mileage records tab with Total fleet emissions card, Search and Filter controls, year Fuel Type and Vehicle dropdowns, and table with Delivery Truck 01 showing report date distance fuel consumed MPG and CO2e emissions](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-fleet-mileage-records.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=9df4bf93ea811b769f5ae6529c7ec940) Mileage records tab with year, fuel type, and vehicle filters and mileage table Use **Search** to find records by vehicle or date, and use the dropdown filters below the search bar to narrow the table. | Filter | Purpose | | - | - | | **Year** | Reporting year for mileage entries (for example, `2026`) | | **Fuel Type** | Limit records to one fuel category | | **Vehicle** | Show mileage for one fleet asset | ## Add a fleet mileage record Click `+ Add Fleet Mileage` to open the **Add Fleet Mileage Record** panel on the right. The panel subtitle reads *Record mileage and fuel for Scope 1 fleet emissions.* ![Add Fleet Mileage Record side panel with Vehicle Report Date Distance Unit fields, Mileage Entry Method toggle for Distance or Odometer, MPG Fuel Consumed and CO2e Emissions calculated fields, auto-calculation info box, and Documentation fields](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-add-fleet-mileage.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=d3fac382e05dbe1d2f37c10649516c95) Add Fleet Mileage Record panel with vehicle information, distance fields, and documentation > [!NOTE] > > **Auto-calculation enabled.** Select a vehicle and enter distance details. EnerG uses the vehicle **Fuel Type** and **Vehicle Type** to preview estimated fuel use and CO₂e output before you submit. **1. Select vehicle and date** Choose **Vehicle** and **Report Date**. Set **Distance Unit** when you report in a unit other than the default. **2. Enter distance or odometer** Select **Distance** or **Odometer** under **Mileage Entry Method**. Enter **Distance** and adjust **MPG** when you have a measured or EPA value. Click **View Conversion Table** for unit or factor references. **3. Review calculated values** Confirm **Fuel Consumed** and **CO₂e Emissions** match your expectations before you submit. **4. Add documentation and submit** Enter **Data Source**, **Document URL**, and **Notes** when you have audit evidence. Click `Submit` to save the record. Click `Close` to exit without saving. After you submit, the record appears on the **Mileage records** tab and updates **Total fleet emissions** on the summary card. Vehicle **Annual Miles** and **Annual CO₂e (t)** on the **Vehicles** tab reflect aggregated mileage for the reporting period. For the mileage record field list, see [fleet fields](/products/energ/reference/emissions-reference#fleet-fields). > [!TIP] > > Keep **Fuel Type** and **Vehicle Type** accurate on each vehicle. Mobile combustion factors depend on both fields when EnerG calculates Scope 1 fleet emissions from mileage records. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand how fleet activity maps to Scope 1. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up the full vehicle and mileage fields. > [card] [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review Scope 1 rollups that include fleet emissions. > [card] [Emissions benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking) > > Compare building emissions alongside fleet totals. > [card] [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions) > > Track refrigerant loss for Scope 1 fugitive reporting. > [card] [Report Builder](/products/energ/finance/reporting) > > Export fleet and emissions data for compliance reporting. # Fugitive emissions Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-fugitive-emissions Record refrigerant loss events for Scope 1 fugitive emissions reporting in EnerG Record refrigerant loss for Scope 1 (Direct greenhouse gas emissions from sources you own or control, such as on-site combustion, fleet fuel, and refrigerant loss.) fugitive emissions (Refrigerant or gas released from equipment during service or leaks, counted as Scope 1 emissions.) reporting in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Expand `Emissions` in the left sidebar and open `Fugitive Emissions`. Fugitive events roll into portfolio Scope 1 totals on [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) and [Benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking). For the accounting model, see [GHG scopes](/products/energ/concepts/emissions-accounting#ghg-scopes). ## Navigate to Fugitive Emissions Click `Emissions` > `Fugitive Emissions` in the portfolio left sidebar. The **Total fugitive emissions** card shows portfolio-wide fugitive output in **kg CO₂e** for the active filters. Use **Search** to find events by equipment, building, or date, and click `Filter` for criteria such as building, refrigerant type, or reporting period. For the columns in the fugitive events table, see [fugitive fields](/products/energ/reference/emissions-reference#fugitive-fields). ## Add a fugitive emission record Click `+ Add Fugitive Event` to open the **Add Fugitive Emission Record** panel on the right. The panel subtitle reads *Add refrigerant service activity for Scope 1 reporting.* > [!NOTE] > > **Auto-calculation enabled.** **Quantity Lost** is calculated as **Quantity Added** minus **Quantity Captured**. EnerG converts pounds to kilograms before applying GWP (Global warming potential: the multiplier that converts a refrigerant quantity into CO2 equivalent.). **1. Select building and refrigerant** Choose **Building** and **Refrigerant / Gas Type**. Set **Report Date** to the service or leak date. **2. Add equipment** Click **Add Equipment** and complete equipment fields when the event applies to a specific asset (for example, `RTU 01`). **3. Enter quantities** Enter **Quantity Added** and **Quantity Captured**. Confirm **Quantity Lost** and **Unit** match the service report. **4. Add service details and documentation** Fill in **Reason for Service** and **Service Provider / Technician** when available. Add **Data Source**, **Document URL**, and **Notes** for audit evidence. **5. Submit the record** Click `Submit` to save the event. Click `Close` to exit without saving. After you submit, the event appears in the fugitive events table and updates **Total fugitive emissions** on the summary card. Each row's **CO₂e Emissions** reflects **Quantity Lost**, refrigerant **GWP**, and unit conversions applied by EnerG. Use the **Edit** and **Delete** actions in the **Actions** column to update or remove a record. For the full field list, see [fugitive fields](/products/energ/reference/emissions-reference#fugitive-fields). > [!TIP] > > Link each event to the correct **Building** and refrigerant type. GWP values differ by gas, so incorrect selections change Scope 1 fugitive totals on portfolio rollups. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand Scope 1 fugitive emissions and GWP. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up the full fugitive record field list. > [card] [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review Scope 1 rollups that include fugitive emissions. > [card] [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions) > > Manage mobile combustion alongside fugitive sources. > [card] [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors) > > Manage factors used in other Scope 1 and Scope 2 calculations. > [card] [Report Builder](/products/energ/finance/reporting) > > Export fugitive and emissions data for compliance reporting. # Portfolio emissions overview Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-emissions-overview Monitor portfolio GHG emissions, offsets, and renewable contracts in EnerG Monitor greenhouse gas emissions across your portfolio in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Expand `Emissions` in the left sidebar and open `Overview` to review scope totals, offsets, and renewable contracts. For the accounting model behind these numbers, see [Emissions accounting](/products/energ/concepts/emissions-accounting). At the building level, open [Emissions](/products/energ/buildings/emissions-overview) after you select a site. Use the portfolio **Emissions** group for benchmarking, emission factors, contracts, fleet, and fugitive tools. ## Navigate to Emissions Overview Click `Emissions` in the portfolio left sidebar, then select `Overview`. ![Emissions Overview page with Region and Select Building filters, summary cards for Total Energy Scope 2 Market-based Scope 2 Location-based and Renewable Energy, GHG Emissions by Scope bar chart, and Metrics table with Trailing 12 Months selector](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-overview.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=587284771d7605d6a823d8ca71e1017e) Emissions Overview with summary cards, GHG chart, and metrics table ### Filter the portfolio Use **Region** and **Select Building** filters at the top right to narrow charts and tables. Values in summary cards, charts, and scope tables update for the scope you select. ### Summary cards Four cards roll up key drivers at the top of the page. The two Scope 2 (Indirect greenhouse gas emissions from purchased energy such as electricity and district steam.) cards separate the two accounting methods described in [location- and market-based Scope 2](/products/energ/concepts/emissions-accounting#location-based-and-market-based-scope-2). | Card | What it shows | | - | - | | **Total Energy** | Portfolio energy consumption for the active filter | | **Scope 2 Market-based** | Market-based Scope 2 emissions in kg CO₂e | | **Scope 2 Location-based** | Location-based Scope 2 emissions in kg CO₂e | | **Renewable Energy** | Renewable energy attributed to the portfolio | ## GHG emissions by scope The **GHG Emissions by Scope (excl RECs & VERs)** chart shows total emissions by year. Turn **Breakdown** on to split bars by scope when your deployment supports it. The vertical axis measures emissions in **kg CO₂e**. The horizontal axis lists calendar years in your reporting window. ## Metrics table The **Metrics** table compares totals to a baseline for the period you select in the dropdown (for example, **Trailing 12 Months**). | Column | Description | | - | - | | **Metric** | Emissions or activity measure name | | **Total** | Value for the selected period | | **Baseline** | Reference value for comparison | | **Change** | Absolute and percentage change. Green indicates improvement; red indicates movement away from the baseline | Common rows include **Scope 2 location-based emissions**, **Scope 2 market-based emissions**, **Energy consumption**, **Energy generation (onsite)**, **Water consumption**, **Waste**, and **Renewable energy**. Use the download control to export the full emissions table to an Excel (`.xlsx`) file. The export uses the same filters and period active on the page. ## Emissions offset and renewable contracts Below the overview charts, review how offsets and renewable energy contracts affect net emissions. ![Emissions Offset Breakdown combination chart showing Residual Emissions REC Avoided and Onsite Avoided by year, and Renewable Energy Contracts table with Year Volume and Contracts columns and Add Contract button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-offset-contracts.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=023ad713daff1c7fc0110035805d5641) Emissions Offset Breakdown chart and Renewable Energy Contracts table ### Emissions offset breakdown The **Emissions Offset Breakdown** chart shows residual emissions, REC avoided, and onsite avoided reductions by year. For definitions of these offset categories, see [RECs and offsets](/products/energ/concepts/emissions-accounting#recs-and-covered-load). Use pagination controls when the chart has more than one view. ### Renewable energy contracts The **Renewable Energy Contracts** table lists contract volume by year. | Column | Description | | - | - | | **Year** | Contract year | | **Volume** | Total contracted renewable volume (for example, kWh) | | **Contracts** | Number of contracts in that year | Click `+ Add Contract` to record a new renewable energy certificate (REC) (Renewable energy certificate: a tradable attribute representing renewable generation that can be allocated and retired.) or volume contract. For full contract libraries, volume allocation, and retirement status, open [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts). ## Scope breakdown The **Scope Breakdown** section includes wide tables for **Annual Emissions (kg CO₂e)** and **Annual Consumptions**. Scroll horizontally to view all scope and service-type columns. Column headers support sorting. ![Scope Breakdown section showing Annual Emissions kg CO2e table with Scope 1 Scope 2 Additional Services RECs and Totals column groups and Annual Consumptions table with matching structure and Grand Total row](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-portfolio-emissions-scope-breakdown.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=b4a21557bef5c816375b03cfbcfabe55) Scope Breakdown with Annual Emissions and Annual Consumptions tables For the column groups in these tables, including Scope 1 (Direct greenhouse gas emissions from sources you own or control, such as on-site combustion, fleet fuel, and refrigerant loss.), Scope 2, Additional Services, and REC columns, see [scope breakdown columns](/products/energ/reference/emissions-reference#scope-columns). > [!TIP] > > Compare **Total Location Based** and **Total Market Based** in **Annual Emissions** when you report both GHG accounting methods. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand scopes, methods, RECs, and factors. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up scope column groups and record fields. > [card] [Emissions benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking) > > Compare Scope 1 and Scope 2 emissions by building. > [card] [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors) > > Manage emission factors used in carbon calculations. > [card] [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) > > Manage REC and volume-based emission contracts. > [card] [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions) > > Manage vehicles and mileage for Scope 1 mobile combustion. > [card] [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions) > > Track refrigerant loss for Scope 1 fugitive reporting. > [card] [Report Builder](/products/energ/finance/reporting) > > Build custom report layouts beyond the on-page emissions table export. # Portfolio meters Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-meters Manage and monitor utility meters across your portfolio in EnerG Open `Meters` in the [portfolio view](/products/energ/get-started/navigation#portfolio-view) left sidebar. The sections below follow the order you use in the product: review the main page, filter the table, map or assign meters, edit properties in batch, create virtual meters, then manage linked meters. For meter detail at a single site, switch to the [building view](/products/energ/get-started/navigation#building-view) and open [Building meters](/products/energ/buildings/meters). ## Meters page The portfolio **Meters** page is one workspace for browsing meters, editing properties, and mapping meters to buildings and spaces. ### Workspace modes | Mode | Use it to | | - | - | | **Browse meters** | Search, sort, and filter the table. Review mapped and unmapped counts. | | **Edit properties** | Change meter fields one at a time or in a [batch update](#batch-update-meter-properties). | | **Map meters** | Review [assisted mapping](#assisted-mapping) suggestions, approve assignments, or complete mappings offline in Excel. | The table stays central in every mode. Building selection sits on the left. Compact service-type filters, search, and sorting stay available while you edit or review. ### Page actions | Action | Purpose | | - | - | | `Go to Linked Meters` | Open the [Linked meters page](#linked-meters-page) to view, edit, or create links | | `+ Create Virtual Meter` | Open the panel to [create a virtual meter](#create-a-virtual-meter) | | `Filters` | Open filter controls for the meters table | | `Assign Meters` | Start the workflow to [assign meters](#assign-meters-to-buildings) to a building | ![Portfolio Meters page showing Total Meters, Meters Not Assigned, Data Completeness at 96 percent, and Inactive Meters summary cards, search and filter bar, Assign Meters action, and a table with Building, Meter Number, Account Number, Account Status, Level, Service Type, Unit, Currency, Status, Data Completeness, Data Source, and Provider Name columns](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-overview.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=baa7816fd8b668b62ca221286a2bd65c) Portfolio Meters page with summary cards, filters, and the meters table ### Summary cards Four cards summarize portfolio health above the table. | Card | What it shows | | - | - | | **Total Meters** | Count of meters across all buildings | | **Meters Not Assigned** | Meters that still need a building assignment | | **Data Completeness** | Portfolio-wide completeness percentage with a `View Details` link | | **Inactive Meters** | Meters marked inactive | Click `View Details` on **Data Completeness** to open a drill-down by building, account, and month. For how EnerG scores coverage and why gaps matter, see [Data completeness](/products/energ/concepts/data-completeness). > [!WARNING] > > Mark meters **inactive** when a utility account closes or the provider issues a new meter number. Inactive meters stay available for historical regressions and M\&V, but they should not count against current completeness if no new bills are expected. Leave inactive meters unassigned or excluded so they do not inflate gap alerts. ![Data Completeness page with Search buildings field, Buildings filter, year selector set to 2026, and an expanded Beacon Hill Complex row showing account ACT-101295 and meters MTR-101295-E01, MTR-101295-G01, and MTR-101295-W01 with monthly completeness percentages in green and red](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-data-completeness.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=1800a5870410a48cde22d164e0ac21ab) Data Completeness page with expandable building rows and monthly percentages On the Data Completeness page, click a **building name** to open [Building information](/products/energ/buildings/building-information). Click a **meter name** to open meter details. ### Meters table The table lists every meter in the portfolio. Each column header supports sorting. Use pagination at the bottom to move through large result sets. Click a **Building** or **Meter Number** link to open [Building information](/products/energ/buildings/building-information) or meter details. For what each column shows, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). ## Filter meters Use the search field above the table to find meters by number or name. Click `Filters` to show the filter row. The button highlights when filters are active. ![Portfolio Meters page with Search meters field, Filters button active, filter row showing Meter Type, Building, Service Type, Scope, and Data Source dropdowns with Utility Hub selected, summary cards for Total Meters, Meters Not Assigned, Data Completeness at 91 percent, and Inactive Meters, and Assign Meters button visible](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-filters.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f871b5c343506bf8d1d025b643d10614) Portfolio Meters with the filter row open and Utility Hub selected as Data Source | Filter | Purpose | | - | - | | **Meter Type** | Narrow by utility, interval, or virtual meters | | **Building** | Limit results to one or more sites | | **Service Type** | Filter by commodity | | **Scope** | Filter by site-level or submeter scope | | **Data Source** | Limit to meters from a specific feed | > [!NOTE] > > You must select a **Data Source** before `Assign Meters` becomes available. ## Assisted mapping Assisted mapping recommends a building or space for each meter. An authorized user confirms the relationship one meter at a time, for a selection, or for all eligible suggestions in the current filters. A high match score alone does not commit a mapping. ### Match score and evidence Each suggestion shows a **0–100 match score**, the candidate building, matching reasons, competing candidates, and clickable evidence. The score ranks available evidence. It is not a calibrated probability. EnerG builds candidates from normalized names and aliases, service addresses, geolocation, verified meter relationships, and provider or account references. After a building is resolved, EnerG can suggest a space when a suite or unit matches a unique space in that building. Statuses such as **Suggested**, **Needs investigation**, and **Left unresolved** help you track work that is still open. **Mapped** means the assignment is confirmed. Imported mappings without enough evidence show as **Not scored**. > [!NOTE] > > When addresses are imported or changed, EnerG looks up map coordinates automatically. Proximity supports a match. It does not prove which building a meter serves by itself. ### Approve mappings **1. Open Map meters** On portfolio `Meters`, switch to **Map meters** mode. Apply filters so you only review the meters you intend to act on. **2. Review each suggestion** Open a meter with a suggestion. Compare the service address, map evidence, score reasons, and any competing buildings. **3. Approve, assign, or leave unresolved** Approve the suggested target for one meter, for selected meters, or for all eligible suggestions in the current filters. Or assign selected meters to a building you choose. Leave conflicting matches in review, or mark them unresolved and reopen later. ### Excel and reference mapping Download the filtered meter list with stable IDs and a building reference sheet. Complete mappings offline, then upload the results. You can also upload a provider, account, and meter list that already includes assigned buildings. EnerG detects headers and previews ready, blocked, unchanged, and skipped rows. Existing mappings stay protected. Duplicate or inconsistent identifiers are flagged. Building and space relationships are validated before changes apply. ## Batch update meter properties In **Edit properties** mode, select individual rows or all filtered results across pages. Choose permitted fields and apply one change to many meters. The dialog shows mixed values, affected counts, and a change summary. Untouched fields stay the same. Clearing a field must be explicit. Each record is validated, and failures are reported. Before-and-after values are retained so you can reverse a batch without overwriting later edits. Meter fields can include account and provider details, service address, assigned building and space, lifecycle status, service scope, billing responsibility, and change history. Leading zeros in identifiers are preserved. Source-controlled fields stay restricted by permission. See the [permissions reference](/products/launchpad/client-organizations/apps/permissions-reference) for `Assign And Unassign Meters` and `Edit Meters`. ## Assign meters to buildings Use `Assign Meters` when you already know the building and want to pick meters from a data source. For scored suggestions and bulk approval, use [assisted mapping](#assisted-mapping) in **Map meters** mode. Use `Assign Meters` to link meters from a data source to a building. You filter by **Data Source**, open the workflow, pick the building, then select meters from that feed. **1. Filter by Data Source** Click `Filters` to show the filter row. Select a **Data Source** such as `Utility Hub`. `Assign Meters` stays disabled until you choose a data source. **2. Click Assign Meters** Click `Assign Meters` next to the filter row. The **Add Meters** dialog opens. **3. Choose a building and click Next** On the **Add Meters** page, search for a building by name. Select one row in the table, then click `Next`. The table lists **Building**, **Type**, and **Address** for each site. ![Add Meters modal with Search field containing kode, a table with Building Type and Address columns showing KODE 1420 Office selected as Office at 1420 Washington Boulevard Detroit, and Cancel and Next buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-add-meters.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=32dfcff66be1cbc3c89a3272b72e8b38) Add Meters dialog to select a building before meter assignment **4. Select meters and click Submit** On the **Add existing Meters** page, search for meters if needed. Check each meter you want to assign. Review **Meter Number**, **Service Type**, **Account Number**, **Provider Name**, and **Address**, then click `Submit`. ![Add existing Meters modal with subtitle Select the meter you want to add to your building, Search Meters field, and a table with Meter Number Meter Name Service Type Account Number Provider Name and Address columns showing Electric and Natural Gas meters from DTE Energy checked with Submit button](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-add-existing.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=a2a9878bb88519efafedd7692ff7a9fa) Add existing Meters dialog with selected meters ready to submit > [!TIP] > > Assigned meters appear in the portfolio **Meters** table and in [Building meters](/products/energ/buildings/meters) for that site. ## Create a virtual meter Click `+ Create Virtual Meter` in the top-right corner of the Meters page. Virtual meters (A virtual meter calculates usage from other meters instead of a direct utility feed.) calculate usage from other meters instead of a direct utility feed. Choose a **Calculation Method**: | Method | Use when | | - | - | | **Custom Formula** | You define an equation from other meters after you set service type, unit, currency, and scope | | **Percentage Split** | You allocate a fixed share of one or more source meters | ![Create Virtual Meter panel with Custom Formula radio selected, fields for Name, Meter Number, Building, Service Type, Unit, Currency, Scope, and Description, and an info banner to select Service Type, Unit, Currency and Scope to configure the equation](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-virtual-meter-formula.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=fcb5973906dafc6ae1fe692e4d56692b) Create Virtual Meter with Custom Formula selected ![Create Virtual Meter panel with Percentage Split radio selected and an info banner to select Service Type, Unit, Currency and Scope to configure the percentage split](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-virtual-meter-split.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=5fef31f7a021f4a01575925e01a1a187) Create Virtual Meter with Percentage Split selected **1. Enter meter details** Provide **Name**, **Meter Number**, **Building**, **Service Type**, **Unit**, **Currency**, **Scope**, and an optional **Description**. **2. Configure the calculation** For **Custom Formula**, build the equation after required fields are set. For **Percentage Split**, define the share across source meters when EnerG prompts you. **3. Submit** Click `Submit`. The virtual meter appears in the portfolio table. ## Linked meters page Click `Go to Linked Meters` on the Meters page to open the **Linked Meters** view. The page title reads **Linked Meters** with the subtitle *Manage the meters linked to your portfolio.* ![Linked Meters page with Search linked meters field, Filters button, Building Service Type and Date Range dropdowns, Link Meters button in the top right, and a table with Name Description Service Category Service Type Primary Meter Linked Meters Created At Updated At columns and edit and delete action icons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-linked-overview.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=1e1ac67b514ee0b30792d50dcddb24a0) Linked Meters page with search, filters, and the links table Use the **Search linked meters...** field to find links by name. Click `Filters` to show **Building**, **Service Type**, and **Date Range** filters when you need to narrow a large portfolio. ### Read link details The table lists every meter link with sortable columns. | Column | Description | | - | - | | **Name** | Label you gave the link when you created it | | **Description** | Optional notes that explain why the meters are linked | | **Service Category** | Broad group such as Energy or Waste | | **Service Type** | Commodity such as Electric or Natural Gas | | **Primary Meter** | Main meter in the relationship. Click the meter ID to open that meter’s details. | | **Linked Meters** | Secondary meter tied to the primary. Click the meter ID to open its details. | | **Created At** | Date the link was created | | **Updated At** | Date of the last change | | **Actions** | Row controls to edit or delete the link | Click a meter ID under **Primary Meter** or **Linked Meters** when you need to review billing data, completeness, or properties for that meter before you change the link. ### Edit or delete a link Use the row actions at the right end of each link. * **Edit** (pencil icon) — Open the **Edit Meter Link** modal to change the name, description, linked meters, or which meter is primary. * **Delete** (trash icon) — Remove the link. The individual meters stay in EnerG; only the relationship is removed. ![Edit Meter Link modal with Name and Description fields, Available Meters panel organized by Electric service type with checkboxes, Timeline Workspace showing two meters with Primary toggles one on and one off, and Close and Update buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-linking-edit.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=d78504d99bc5e3657df3dbc8fbd3acc3) Edit Meter Link modal with available meters and timeline workspace **1. Open the link for editing** On the Linked Meters page, click the **edit** icon on the link row. **2. Update the link** Change **Name** or **Description** if needed. In **Available Meters**, select or clear meters to add or remove them from the **Timeline Workspace**. Turn **Primary** on for the meter that should drive the stitched timeline. **3. Save changes** Click `Update`. The table refreshes with your changes. ## Link meters Meter links stitch timelines across related feeds so analytics stay continuous when accounts or meter numbers change. Create a new link from the Linked Meters page. **1. Click Link Meters** On the Linked Meters page, click `Link Meters` in the top-right corner. The **Meter Linking** modal opens. ![Meter Linking modal with Name and Description fields, Available Meters panel with Organize by Data Source and a scrollable meter list, empty Timeline Workspace with Drag Meters to Link instruction, and Close and Create buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-linking-create.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9ae22d3c3063f7db5e28155010cc0e5a) Meter Linking modal before meters are added to the workspace **2. Enter a name and description** Fill in **Name** and **Description** so operators can recognize the link later. **3. Select two meters** In **Available Meters**, search or organize the list by **Data Source** or **Service Type**. Select the first meter you want to link, then select the second meter. You can check meters in the list or drag them into the **Timeline Workspace**. ![Meter Linking modal with Name and Description fields, Available Meters organized by Service Type on the left, Timeline Workspace on the right showing Cardboard meter with Primary toggle, and Close and Create buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-portfolio-meters-linking-workspace.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=f8922f0be7c2794ad1d703b147b138dd) Meter Linking workspace with meters selected and a primary meter designated **4. Choose the primary meter** In the **Timeline Workspace**, turn **Primary** on for the meter that should anchor comparisons. Leave **Primary** off for the secondary meter. **5. Click Create** Click `Create`. A success message confirms the link. The new row appears on the Linked Meters table. > [!TIP] > > Link meters that represent the same physical account across a meter change or data source migration. Keep service type and scope aligned so stitched timelines do not mix unrelated commodities. ## Next steps > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Connect feeds before you assign meters across the portfolio. > [card] [Building meters](/products/energ/buildings/meters) > > Review and edit meters after you open a building. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Resolve data quality alerts for portfolio meters. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Select a building to continue work in the building view. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how feeds and meters organize portfolio data. > [card] [Data and meter fields](/products/energ/reference/data-and-meter-fields) > > Look up meter columns, service types, and status values. # Portfolio targets Source: https://docs.kodelabs.com/products/energ/analytics/portfolio-targets Create and track sustainability reduction targets across your portfolio in EnerG Define and monitor portfolio-level reduction targets in the [portfolio view](/products/energ/get-started/navigation#portfolio-view). Click `Target` in the left sidebar to open the targets list and dashboards. For target progress at one site, open the [building view](/products/energ/get-started/navigation#building-view) and select **Target** under **Dashboards** > **Energy** on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#target). ## Navigate to portfolio targets Click `Target` in the portfolio left sidebar. The page lists active and historical reduction goals. ![Targets page at portfolio level listing targets with columns for Service Category, Type, Metric, Start Date, End Date, Reduction method, and Buildings count](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-sustainability-targets-list.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=84b09d018c7c410bbf04d781b348bb28) Portfolio Targets list showing active reduction goals ## Create a portfolio target **1. Start target creation** On the `Target` page, click the create button to open the three-step `Target Information` wizard. **2. Define target parameters** In step 1 (`Target Setup`), enter a `Target Name` and optional `Description`. Configure **Service Type**, **Target Type**, **Metric Category**, and the **Baseline** date range. ![Target Information wizard step 1 showing Target Setup with service type, target type, metric category, and baseline date range fields](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-sustainability-target-form-filled.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=cb8dd3f634c8271c4345bfdd7c1bb1b1) Target creation wizard step 1 **3. Choose a reduction type** In step 2 (`Reduction Type`), select how reductions accumulate over time. ![Target Information wizard step 2 showing Reduction Type options including Annual Reduction as Linear](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-sustainability-target-reduction.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=4164e3dc536c593d4771bf1499445891) Reduction Type step with Annual Reduction selected **4. Scope buildings** In step 3 (`Building Assessment`), choose `Apply to Entire Portfolio` or `Apply to Specific Buildings`. ![Target Information wizard step 3 showing Building Assessment with Apply to Specific Buildings selected](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-sustainability-target-buildings.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=0e45245dd744a4912496f50e684c6452) Building Assessment step with specific buildings selected **5. Submit the target** Click `Submit`. The target appears in the portfolio list and begins tracking. ## Choose a reduction method Targets support annual, compounding, and custom-milestone reductions. For how each method applies your goal against the baseline, see [target calculation methods](/products/energ/reference/calculations-and-parameters#target-methods). ## Read portfolio target dashboards The portfolio view lists all active targets with unit conversions when they apply. Click any target to open charts that compare actual consumption to target and baseline lines. ![Energy Target dashboard at portfolio level showing Target Energy Comparison line chart and Delta from Target and Delta from Baseline bar charts](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-analytics-portfolio-target-view.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=0fa20c67798957c6c2173d38b682e792) Portfolio target dashboard with actual, target, and baseline trends ## Next steps > [card] [Building Energy — Target](/products/energ/analytics/building-dashboards-energy#target) > > Review target progress for one building. > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Model conservation investments that support your targets. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Compare buildings while you monitor target progress. > [card] [Portfolio Energy dashboard](/products/energ/analytics/portfolio-dashboards-energy) > > Review portfolio energy KPIs alongside formal targets. # Building dashboards overview Source: https://docs.kodelabs.com/products/energ/analytics/site-dashboards Open building-level Energy, interval, and waste dashboards in EnerG Building dashboards show how one site performs on energy, water, waste, and related metrics. In the [building view](/products/energ/get-started/navigation#building-view), expand `Dashboards` in the left sidebar to open commodity dashboards and specialized reports. Select a building from portfolio `Home`, then click `Go to Building` before you open a dashboard. ## Dashboard categories | Submenu item | Documentation | | - | - | | `Energy` | [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) | | `Water` | [Building Water dashboard](/products/energ/analytics/building-dashboards-water) | | `Waste` | [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) | ## Energy dashboards and reports `Energy` is the default dashboard category for most building reviews. It includes **Monthly Reports** with **Usage** and **Cost** lenses, service-type and meter breakdowns, and baseline comparison charts. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Review Monthly Reports, usage and cost charts, and baseline comparisons for one building. The Energy secondary menu also links to `Annual Reports`, `Comparison`, `Interval Trends`, `Target`, `Data Quality`, `Data Table`, and `Baseline Analysis`. See [Portfolio and building navigation](/products/energ/get-started/navigation#energy-dashboard-report-menu) for the full list. ## Water dashboards and reports `Water` includes **Monthly Reports** with **Usage** and **Cost** lenses, service-type and meter breakdowns, and baseline comparison charts for one building. > [card] [Building Water dashboard](/products/energ/analytics/building-dashboards-water) > > Review Monthly Reports, usage and cost charts, and baseline comparisons for one building. The Water secondary menu also links to `Annual Reports`, `Comparison`, `Target`, `Data Quality`, and `Data Table`. ## Waste dashboard `Waste` shows KPI cards, monthly quantity and cost charts, diversion rate, and composition breakdowns for one building. Unlike Energy and Water, there is no secondary report menu. > [card] [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) > > Review diversion rate, capture rate, and waste composition for the selected building. Use the [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) to create streams and enter pickup data. ## Interval trends Open **Interval Trends** from the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#interval-trends) report menu after you select **Energy** under **Dashboards**. > [card] [Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends) > > Analyze hourly or 15-minute usage when monthly charts need more detail. ## Compare to portfolio > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Rank this building against peers on EUI, WUI, and GHG before you return to site detail. # Building information Source: https://docs.kodelabs.com/products/energ/buildings/building-information Configure building properties, occupancy data, and operational details in EnerG You configure building properties, occupancy, and operations at the building level in EnerG. The product pulls high-level attributes from Launchpad when available, and you complete energy-specific fields through a five-step wizard in KODE OS. ## Navigate to Building Information **1. Select a building** From the EnerG `Home` page, click a building in the left sidebar. Click `Go to Building` at the top of the detail panel. **2. Open Building Information** In the building-level left sidebar, click `Building Information`. The `Building Data Entry` page opens with a five-step progress wizard on the left. ![Building Data Entry page for Valley View Megastore with progress sidebar showing step 1 General Info active and steps for Site and Energy Operating Hours Weather Data and Envelope, General Information fields for Building Name Property Type Building Area address Year Built and HVAC systems, and an Edit button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-information-general-info.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=c25ed19bb1ec764cc4c4eaf097a0af5e) Building Data Entry page with the five-step progress wizard > [!NOTE] > > High-level attributes synchronize from Launchpad when the integration is active. You confirm these values so downstream energy metrics stay aligned with portfolio records. ## Edit building data Click `Edit Informations` in the top-right corner to enable editing across all five wizard steps. Complete each step using the `Next` button at the bottom, or click any step number in the left sidebar to jump directly. ## Step 1: General Info The `General Info` step captures core building attributes. Launchpad supplies baseline values such as total area, address, and year built. You verify these and fill any gaps. **Building Name** `Field` Display name for the building across EnerG dashboards and reports. **Property Type** `Dropdown` Building category such as Office, Retail, Multifamily, or Industrial. This controls which conditional fields appear in later steps. **Building Area** `Field` Total conditioned area in square feet. This value drives EUI calculations. Maintain [area over time](#building-area-over-time) when square footage changes. **Electric Capacity** `Field` Building electric capacity when you track service size or peak electrical capability for the site. **Irrigation Area** `Field` Irrigated area when the building has landscaped grounds that affect water metrics. **Parking Type** `Dropdown` Parking structure category. This field affects energy exclusion options. **Occupancy Type** `Dropdown` How the building is occupied, such as single-occupant or multi-occupant. **Year Built** `Field` Original construction year. Used for age-based benchmarking comparisons. **Latest Year Renovation** `Field` Most recent renovation year when applicable. **Floors** `Field` Number of floors. Used for intensity metrics that scale by geometry. **Primary Heating System** `Dropdown` Primary heating equipment type. Drives heating degree-day correlations in energy models. **Primary Cooling System** `Dropdown` Primary cooling equipment type. Drives cooling degree-day correlations in energy models. > [!NOTE] > > Primary HVAC selections drive downstream cooling and heating degree-day correlations. Select the systems that represent the majority of conditioned load. A card at the bottom of this step shows the detected property type with an **optional** expandable section for conditional fields such as retail configuration. ## Step 2: Site and Energy The `Site & Energy` step captures energy-specific properties. You record drivers that shape energy models and comparisons. ![Building Data Entry Site and Energy step showing toggles for Has Non-LED Lighting Includes Parking Consumption Includes Tenant Consumption Has Data Center Has EV Chargers and Has Submetering, plus Power Procurement Coverage Percentage and On Site Renewable dropdowns](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-information-site-energy.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=fdea65b0ec36db5e68c811d3b46663e5) Site and Energy step with exclusion toggles and procurement fields | Toggle | Purpose | | - | - | | **Has Non-LED Lighting?** | Flag when legacy lighting remains in the building | | **Includes Parking Consumption** | Exclude or include parking energy from portfolio totals | | **Includes Tenant Consumption** | Exclude or include occupant-space energy from portfolio totals | | **Has Data Center?** | Flag data center load on site | | **Has EV Chargers?** | Flag electric vehicle charging load | | **Has Submetering?** | Indicate whether submeters are present | **Power Procurement** `Dropdown` How the building procures electricity, such as grid supply or green power contracts. **Coverage Percentage** `Field` Share of load covered by the selected procurement option when applicable. **On Site Renewable** `Dropdown` On-site renewable generation type when the building hosts solar, wind, or other systems. > [!WARNING] > > Misclassified exclusions shift EUI and carbon totals for the entire site. Confirm your governance rules before toggling exclusions. ## Step 3: Operating Hours The `Operating Hours` step defines the weekly schedule that drives energy analysis and interval open-vs-closed charts. ![Building Data Entry Operating Hours step with table for each day showing Starting Hour 06:00 AM Ending Hour 11:00 PM and Working Day toggles enabled for Monday through Sunday](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-information-operating-hours.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=fd3fe957d3b706b44089d37279b27967) Operating Hours step with daily start and end times | Column | Purpose | | - | - | | **Day** | Day of the week | | **Starting Hour** | Time operations begin, with AM/PM selector | | **Ending Hour** | Time operations end, with AM/PM selector | | **Working Day** | Toggle to include or exclude the day from the operating schedule | **1. Define the weekly pattern** Enter standard open and close times for each day that reflect typical operation. **2. Capture exceptions** Add holiday or seasonal adjustments when they materially change usage patterns. Saved hours feed open-vs-closed interval charts on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy). ## Step 4: Weather Data The `Weather Data` step configures degree-day calculations and historical weather collection. ![Building Data Entry Weather Data step showing banner that weather data is available from March 18 2026 with Collect Historical Data button back to January 1 2022, and Cooling Base Temperature and Heating Base Temperature fields](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-information-weather-data.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b2b8e102b612c9db67b4a38678d6c471) Weather Data step with historical collection banner and base temperatures When weather is already available, a banner shows the earliest date in the system. Click **Collect Historical Data** to backfill an earlier period when you need a longer record for models or baselines. **Cooling base temperature** `Number` Reference temperature for cooling degree-day calculations. Typical values range from 60 to 65 degrees Fahrenheit. **Heating base temperature** `Number` Reference temperature for heating degree-day calculations. Typical values range from 60 to 65 degrees Fahrenheit. **What heating and cooling degree days represent** Heating and cooling degree days measure how much outdoor weather departs from your base temperatures during each day. Higher values indicate greater demand for heating or cooling. ## Step 5: Envelope The `Envelope` step describes the building shell performance. You capture facade type, condition, window characteristics, and roof type for documentation and future modeling. ![Building Data Entry Envelope step showing dropdown fields for Building Facade Type Facade Condition Window Type and Roof Type with progress sidebar showing step 5 active](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-information-envelope.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=37a5876aebd2815dda9e2ec564fbe8fb) Envelope step with facade and roof fields **Building Facade Type** `Dropdown` Dominant exterior wall construction or cladding type. **Facade Condition** `Dropdown` Overall observed condition of the facade. **Window Type** `Dropdown` Dominant glazing or window assembly type. **Roof Type** `Dropdown` Roof construction or membrane type. **1. Describe the facade** Select facade type and rate overall condition as observed during a site review. **2. Record glazing and roof** Note dominant window types and roof construction that affect thermal loads. **3. Save envelope data** Click `Save` to attach the envelope profile to the building record. ## Building status Mark a building **Deactivated** when it is divested or no longer active in the portfolio. Deactivated buildings show a status tag so analysts can exclude them from live benchmarking and budget rollups while historical records remain available. ## Building area over time Building area can change after renovations or re-measurement. You maintain a time series so historical performance reflects the correct denominator for EUI calculations. **1. Add an area record** In `Building Information`, locate the area history section and add a new entry. **2. Set effective dates** Enter start and end dates that bound when that area value applies. **3. Close the row when area changes** Add the next interval when the measured area changes, then click `Save`. > [!TIP] > > Close the prior area row on the last day it was valid before you add the next value. Complete the property-type conditional fields on **General Info** before you run annual reporting so templates stay complete. ## Next steps > [card] [Meters](/products/energ/buildings/meters) > > Review utility and interval meters assigned to this building. > [card] [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) > > Define baseline periods for energy, water, and waste. > [card] [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) > > Configure waste streams and diversion reporting for the site. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Compare this building against portfolio peers using EUI, WUI, and carbon metrics. # Building data sources Source: https://docs.kodelabs.com/products/energ/buildings/data-sources Review data sources connected to one building in EnerG Review data sources that feed meters for one building in the [building view](/products/energ/get-started/navigation#building-view). Expand `Data Sources` in the building left sidebar and open **Overview** or a connector page. Portfolio-wide connections and credentials are managed from [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) in the portfolio view. ## What you can do at building scope At the building level, you confirm which feeds supply meters for the site. You map meters, review connection status, and open connector-specific settings without changing portfolio-wide credentials. For how feeds and meters organize EnerG data, see [Data sources and meters](/products/energ/concepts/data-and-meters). Use the same connector guides for detailed setup steps: * [Arcadia](/products/energ/data-sources/arcadia) * [CSV uploads](/products/energ/data-sources/csv-uploads) * [Manual entry](/products/energ/data-sources/manual-entry) * [KODE OS data source](/products/energ/data-sources/kode-os-data-source) ## Next steps > [card] [Building meters](/products/energ/buildings/meters) > > Review meters assigned to this building. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Manage portfolio-wide data source connections. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Analyze usage after feeds are connected. > [card] [Data quality](/products/energ/data-quality/data-quality-overview) > > Review completeness and alerts for this building. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how utility bills and interval reads feed EnerG. # Building emissions overview Source: https://docs.kodelabs.com/products/energ/buildings/emissions-overview Monitor GHG emissions, offsets, and renewable contracts for one building in EnerG Monitor emission drivers for one building in the [building view](/products/energ/get-started/navigation#building-view). Click **Emissions** in the left sidebar to review summary cards, scope tables, offsets, and renewable contracts. For portfolio rollups, see [Portfolio emissions overview](/products/energ/analytics/portfolio-emissions-overview). For scopes and accounting methods, see [Emissions accounting](/products/energ/concepts/emissions-accounting). Use the portfolio **Emissions** group for [Benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking), [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors), [Contracts](/products/energ/analytics/portfolio-emissions-contracts), [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions), and [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ## Open Emissions Overview **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Emissions** Click **Emissions** in the left sidebar. ![Emissions Overview for One Financial Plaza with Region filters Total Energy 5616495 kWh Scope 2 Market-based 0 Scope 2 Location-based 507296 kg CO2e GHG Emissions by Scope chart and Metrics table Trailing 12 Months](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-emissions-overview.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=26b815ab2616c1dbf6b85efcf5068560) Building Emissions Overview with summary cards and metrics table ### Filter by region Use **Region** and the dependent region selector at the top right when your building spans multiple reporting regions. Summary cards, charts, and tables update for the scope you select. ### Summary cards Four cards roll up key drivers for the building. The two Scope 2 (Indirect greenhouse gas emissions from purchased energy such as electricity and district steam.) cards separate the methods described in [location- and market-based Scope 2](/products/energ/concepts/emissions-accounting#location-based-and-market-based-scope-2). | Card | What it shows | | - | - | | **Total Energy** | Building energy consumption, such as **5,616,495 kWh** | | **Scope 2 Market-based** | Market-based Scope 2 emissions in kg CO₂e | | **Scope 2 Location-based** | Location-based Scope 2 emissions in kg CO₂e | | **Renewable Energy** | Renewable energy attributed to the site | ## GHG emissions by scope The **GHG Emissions by Scope (excl RECs & VERs)** chart shows total emissions by year. Turn **Breakdown** on to split bars by scope when your deployment supports it. The vertical axis measures **kg CO₂e**. Compare year-over-year totals before you drill into the metrics table. ## Metrics table The **Metrics** table compares totals to a baseline for the period in the dropdown, such as **Trailing 12 Months**. | Column | What it shows | | - | - | | **Metric** | Emissions or activity measure name | | **Total** | Value for the selected period | | **Baseline** | Reference value for comparison | | **Change** | Absolute and percent change. Green indicates improvement; red indicates movement away from baseline | Common rows include **Scope 2 location-based emissions**, **Scope 2 market-based emissions**, **Energy consumption**, **Water consumption**, **Waste**, and **Renewable energy certificates**. Use the download control to export the full emissions table to an Excel (`.xlsx`) file. The export uses the same filters and period active on the page. ## Emissions offset and renewable contracts Scroll below the overview charts for offset visualization and contract management. ![Emissions Offset Breakdown chart with Residual Emissions REC Avoided bars by 2024 2025 2026 and Renewable Energy Contracts card with No renewable contracts message and Add Contract button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-emissions-offset.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=13937eb95964f7c9fdb8a5c91a5be5ba) Emissions Offset Breakdown and Renewable Energy Contracts empty state The **Emissions Offset Breakdown** chart shows residual emissions, REC avoided, onsite avoided, and onsite energy by year. For definitions of these offset series, see [RECs and offsets](/products/energ/concepts/emissions-accounting#recs-and-covered-load). Use pagination when the chart has more than one view. The **Renewable Energy Contracts** card lists contract volume by year when contracts exist. Click **+ Add Contract** to record an instrument, or open [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) for the full contract library and retirement workflow. ## Scope breakdown The **Scope Breakdown** section includes **Annual Emissions (kg CO₂e)**, **Annual Consumptions**, and **Annual Factors** tables. Scroll horizontally to view all columns. ![Scope Breakdown with Annual Emissions table Scope 2 District Steam and Electric Additional Services Water REC Retired Total Location Based Grand Total 5426308 and Annual Consumptions table with kWh and L columns](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-emissions-scope-breakdown.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=3956aae9c16aafaf98784a42d53a8c93) Scope Breakdown Annual Emissions and Annual Consumptions tables For the Scope 2, Additional Services, REC, and Totals column groups, plus the intensity factors shown in **Annual Factors**, see [scope breakdown columns](/products/energ/reference/emissions-reference#scope-columns). > [!TIP] > > Compare **Total Location Based** and **Total Market Based** when you report both GHG accounting methods. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand scopes, methods, RECs, and factors. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up scope column groups and record fields. > [card] [Emissions benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking) > > Compare Scope 1 and Scope 2 emissions across buildings. > [card] [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) > > Create, allocate, and retire REC volume. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Toggle **Emissions** on monthly reports alongside usage and cost. # Building meters Source: https://docs.kodelabs.com/products/energ/buildings/meters View, manage, and configure utility and interval meters for one building in EnerG Open `Meters` in the [building view](/products/energ/get-started/navigation#building-view) left sidebar after you select a site. You review meter lists, billing data, and properties for that building only. To assign meters or manage links across the estate, use [Portfolio meters](/products/energ/analytics/portfolio-meters) in the portfolio view. ## Navigate to building meters **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), click a building in the left sidebar. Click `Go to Building` at the top of the detail panel. **2. Open Meters** Click `Meters` in the building left sidebar. The page lists meters grouped by service category. ![Meters page for KODE 1420 Office showing meter hierarchy grouped by Energy Electric Lighting Natural Gas and Steam, main table with Meter Level Service Type Unit Status Completeness Data Source and Provider Name columns, and Compare Meters and Unassign Meters buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meters-list.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b1c4f8061cae61f3e15c19f56084c025) Building Meters page with category tree and meter table ## Understand the meter list The left panel groups meters by service category: **Energy** (Electric, Lighting, Natural Gas, Steam), **Water**, and **Waste**. Each meter displays its number and a badge indicating its type. * **utility** — the meter receives monthly billing data from a provider * **interval** — the meter receives high-frequency interval reads (Interval reads record usage every hour or every 15 minutes for load shapes, forecasting, and M\&V.) (hourly or 15-minute) * **both** — the meter has utility billing data and interval data Click `All` at the top of the meter list to see the total count, such as **All (12)**. Select a category to narrow the table. Click a meter row or name to open its detail view. For how bills and interval reads feed meters, see [Data sources and meters](/products/energ/concepts/data-and-meters). ### Meter table columns The main table lists every meter assigned to the building. For what each column shows, such as `Level`, `Completeness`, and `Data Source`, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). ## Filter and search meters Use the search bar and filter controls above the table to find meters quickly. ![Meters filter row with Search Meters field Select Data Sources dropdown Filter button, and second row with Level Service Type Unit and Status dropdowns and Clear All link](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meters-filters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=73d95201444c8335fecd5e036e77adfc) Meter search and filter controls | Control | Purpose | | - | - | | **Search Meters** | Find a meter by number or name | | **Select Data Sources** | Limit results to one or more data sources | | **Filter** | Open advanced filters | | **Level** | Filter by main or sub meter | | **Service Type** | Filter by commodity | | **Unit** | Filter by usage unit | | **Status** | Filter by active or inactive | | **Clear All** | Reset every filter | ## Compare meters Click **Compare Meters** in the top-right corner to open **Meter Comparison Sets**. Check **Completeness** in the meters table first. Low scores often mean billing data is missing before a comparison is meaningful. See [Meter comparisons](/products/energ/data-quality/meter-comparisons) for the full workflow, screenshots, and threshold guidance. ## Unassign meters from the building Click `Unassign Meters` to remove meters from the building record without deleting historical data from the portfolio. ![Unlink Meters from Building modal with table of Meter Number Meter Name and Provider Name with checkboxes, pagination 1-10 of 11, and Cancel and Unlink buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meters-unlink.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=a882837432ee2d213abd2ac6b037ed65) Unlink Meters from Building dialog with meter selection table Select the meters to unlink, then click `Unlink`. Use [Portfolio meters](/products/energ/analytics/portfolio-meters) when you need to assign meters to a different building. ## Review meter detail Select any meter from the list to open its detail view. The header shows the meter number, a date range picker, and action buttons **Edit Meter Data**, **+ Add Meter Data**, and a **three-dot** overflow menu for bulk import. ![Meter detail for 2775715 08 showing Edit Meter Data and Add Meter Data buttons and three-dot menu beside them, General Information card, and Interval Data tab with hourly consumption heatmap](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-detail-header-actions.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b63edc9e4395dbc0256cf3e75a17038d) Meter detail header with Edit Meter Data, Add Meter Data, and overflow menu ![Meter detail for 2775715 08 at KODE 1420 Office showing General Information with Service Address and Account Number, Overview tab with Bill Default Usage selected, and Monthly Consumption per Billing Period and Calendarized Monthly Consumption bar charts in kWh](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-detail-overview.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=52e9502ae2534a07132d50b571c2b00a) Meter detail with General Information and Overview charts The detail view includes five tabs: **Overview**, **Data Quality**, **Data Table**, **Interval Data**, and **Properties**. ### General information The **General Information** card summarizes account metadata from the utility feed, such as service address, account number, and connection status. For each field, see [General information fields](/products/energ/reference/data-and-meter-fields#general-information). ### Overview tab The `Overview` tab shows two side-by-side charts for the selected year. * **Monthly Consumption per Billing Period** — raw usage totals per billing cycle, with **Provider** data in teal and **Accrued** data in striped bars * **Calendarized Monthly Consumption** — the same data after calendarization (Calendarization spreads each billing period across calendar months using average daily consumption, so January always means January.) spreads it across calendar months so January always means January Toggle between **Bill Default Usage** and **Metric Usage** above the charts to switch the consumption source. The first screenshot above shows **Bill Default Usage**. ![Meter Overview tab with Metric Usage toggle selected showing Monthly Consumption per Billing Period and Calendarized Monthly Consumption charts with Provider legend in kWh](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-overview-metric-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=8d1009a06a981c601365a088d9605849) Overview with Metric Usage selected For how calendarization works and why it matters, see [Data sources and meters](/products/energ/concepts/data-and-meters). ### Data Quality tab The `Data Quality` tab shows billing coverage for the selected meter and lists each bill period in a table below the chart. Use it when you investigate completeness gaps. See [Data completeness](/products/energ/data-quality/data-completeness#review-gaps-on-a-meter) for how scores roll up and how to fix common causes. ![Meter Data Quality tab showing Bills Data Quality horizontal chart with Complete green segments for meter 2775715 08 from December 2025 to May 2026, and table with Type Complete Provider DTE Energy Service Type Electric Statement Type BILL link and usage in kWh](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-data-quality.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e1c492a01b983308ed3d77f2b52f5f67) Data Quality tab with Bills Data Quality chart and billing table #### Bills Data Quality chart The **Bills Data Quality** chart is a horizontal timeline for the open meter. Color segments show how each period is classified, from complete coverage to gaps and overlaps. For the color legend, see [Data quality legend](/products/energ/reference/data-and-meter-fields#data-quality-legend). #### Billing detail table The table lists individual billing records for the meter, including provider, service type, statement type, usage, and billing dates. For column definitions, see [Data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). When a bill PDF was uploaded with the record, **Statement Type** shows a **BILL** link with a view icon. Click **BILL** to open the PDF in a new viewer so you can verify usage and charges against the table row. > [!TIP] > > Open the bill PDF when you dispute a row or need to confirm the billed period before you edit meter data on the **Overview** tab. ### Data Table tab The `Data Table` tab lists every billing record for the open meter in a sortable table. Use service tag filters and **Export** to download rows for offline review. #### Billing Period and Calendarized tabs Switch between two views of the same underlying data. | Tab | Purpose | | - | - | | **Billing Period** | One row per billing period as the utility reports it | | **Calendarized** | Usage and cost spread across calendar months | ![Meter Data Table tab with Billing Period selected showing Full Service filter Export button and table with meter 2775715 08 Electric DTE Energy Michigan charges usage in kWh Data Origin Provider and start dates](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-data-table-billing.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e537e0d8f9d722234c6d963f0bb4040b) Data Table Billing Period tab for a single meter On **Calendarized**, each row aligns usage and cost to calendar months. **Estimated** may show **Yes** when the row is projected or not yet final. ![Meter Data Table tab with Calendarized selected showing meter 2775715 08 rows with Estimated Yes Provider Data Origin usage in kWh and calendar month start and end dates](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-data-table-calendarized.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=00219d2494e30425e02b622a84315260) Data Table Calendarized tab for a single meter #### Table columns Sort any column with the header arrows. Scroll horizontally to reach **Start Date** and **End Date**. For what each column shows, see [Data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). A **Billing Period** row with **Data Origin** **Provider** and no **Estimated** flag reflects a final bill from the utility. **Calendarized** rows with **Estimated** **Yes** may appear before the final bill posts for that month. #### Export meter data Click **Export** on the **Data Table** tab to download the filtered rows. The **Data Export** dialog offers three export modes. | Mode | Purpose | | - | - | | **All Fields** | Export every column in the table | | **Custom Columns** | Choose columns, order, and formats before export | | **Existing Template** | Run a saved column layout | ![Data Export modal with All Fields Custom Columns and Existing Template radio options and Cancel and Submit buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-dialog.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=bdcfc69ae4875c431e6103425769bf0a) Data Export dialog with export mode options **1. Choose an export mode** Select **All Fields** for a full export, or choose **Custom Columns** or **Existing Template** when you need a repeatable layout. **2. Configure custom columns (optional)** When you select **Custom Columns**, click **Next** to open **Custom Fields**. ![Data Export modal with Custom Columns selected and Next button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-custom-columns.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=fd859c62428e6c949fd572c82850eb6c) Custom Columns selected in Data Export ![Custom Fields modal with Decimal Precision 2 Decimals Date Format MM/dd/yyyy and checkboxes for Building Name Meter Name Start Date Usage and Usage Unit Name with drag handles](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-custom-fields.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=64268e98f5711a77e1da7eb146247c58) Custom Fields column picker with decimal and date format Check the columns to include, such as **Building Name**, **Meter Name**, **Start Date**, **Usage**, and **Usage Unit Name**. Drag the handles to reorder rows. Set **Decimal Precision** and **Date Format** for the export file. **3. Save a template (optional)** Click **Save Template** to store the current column layout. Enter a name such as **Template 1**, then click **Save & Export** to download and save the layout for next time. ![Save this layout as a template dialog with Name field Template 1 and Cancel and Save and Export buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-save-template.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=cc3f9b07578b174790559c8dcb0f90ee) Save layout as template before export **4. Use an existing template (optional)** Select **Existing Template**, choose a template from the **Template Name** dropdown, and click **Show Details** to review included columns and formats. Use the pencil icon to edit the template or the trash icon to delete it. ![Data Export modal with Existing Template selected Template Name dropdown Template 1 edit and delete icons and Show Details link](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-existing-template.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=015d52d723e2bebac1be13b43840d5da) Existing Template selected with template dropdown ![Data Export Existing Template with Hide Details showing 2 Decimals MM/dd/yyyy date format and columns Building Name Meter Name Start Date Usage and Usage Unit Name](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-export-template-details.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=cd44afef119974f57ed1f2649035ef0c) Template details with column list and formats **5. Submit the export** Click **Submit** to generate the file. EnerG applies your current table filters and the active **Billing Period** or **Calendarized** tab. The same **Export** workflow is available on building and portfolio **Data Table** views when you need a wider scope than one meter. ### Interval Data tab The `Interval Data` tab appears when the meter has high-frequency reads. Use it to analyze sub-daily patterns that monthly bills cannot show. #### Controls | Control | Purpose | | - | - | | **Date range** | Limit charts to a start and end date, such as `2026/05/01 – 2026/05/21` | | **Point type** | Select the interval metric, such as **Differential Electric Energy Accumulator** or **Total Energy** | The point type must match the interval feed you configured in [meter comparisons](/products/energ/data-quality/meter-comparisons). #### Interval Hourly Consumption **Interval Hourly Consumption** is a heat map with hours of day on the horizontal axis and days on the vertical axis. Color intensity reflects kWh for each hour. A **Degree Days** chart on the right shares the same day axis. Red bars extend right for heating degree days; blue bars extend left for cooling degree days. Use it to relate load shape to weather. ![Interval Data tab showing Interval Hourly Consumption heat map by hour from 12AM to 10PM and day 1 to 21 with color scale 4.16 to 15.04 kWh and Degree Days bars beside for May 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-interval-hourly-consumption.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=0ea378f11958479a457375b18ab6db3c) Interval Hourly Consumption heat map with Degree Days Brighter cells during business hours often indicate base building load. Teal cells in early morning hours suggest equipment off or setback mode. #### Interval Daily Consumption **Interval Daily Consumption** plots total daily usage as teal bars. An orange **Temperature** line on the secondary axis shows average daily temperature in °F when weather data is available. ![Interval Daily Consumption bar chart in kWh with orange temperature line in Fahrenheit by day from May 01 to May 22 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-interval-daily-usage-temperature.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e7e1890967faa319b1dbbf148988ac51) Interval Daily Consumption with temperature overlay #### Daily Consumption by calendar month **Daily Consumption** (year view) is a heat map with one row per day of month (1–31) and one column per calendar month. Color intensity reflects daily kWh across the selected year. ![Daily Consumption heat map showing daily kWh usage by day of month from 1 to 31 across months January through May with color scale from 162.33 kWh in teal to 215.17 kWh in red](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-interval-daily-consumption.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=23431e9c9c89f645f9a633bf78a67f8e) Daily Consumption heat map by day of month and calendar month Use this view to compare the same calendar day across months, such as whether the 15th of each month runs hotter than other days. ### Properties tab The `Properties` tab displays configuration for the open meter, such as scope, unit, service type, and `Include In Metrics`. Click **Edit properties** to change values, then save. For each field, see [Meter properties](/products/energ/reference/data-and-meter-fields#properties). ![Meter Properties tab for 2775715 08 showing Description Tenant Equipment End Use Scope Main Meter Unit kWh Currency US Dollar Service Type Electric Include In Metrics toggle on and Edit properties button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-properties.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3df23b9f5710b410bccb9a6021071c5f) Properties tab read-only view In edit mode, additional lifecycle and source fields appear, including service start and end dates, status, data source, and the deregulated supply toggle. ![Meter Properties edit view showing Service Start Date 12/12/2024 Service End Date Status ACTIVE Data Source Utility Hub Origin Granularity Deregulated toggle and Include In Metrics on](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-properties-edit.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=249a6000b27d2cea11798e4d5e192407) Properties tab in edit mode with service dates and data source > [!WARNING] > > Set **Service End Date** and mark the meter inactive instead of deleting historical billing rows when a utility account closes. ## Edit billing records You modify individual billing records when you find errors or need to correct imported data. **1. Open the meter detail** Select the meter from the list, then confirm you are on the **Overview** tab. **2. Click Edit Meter Data** Click **Edit Meter Data** in the top-right corner. The **Edit Meter Details** table opens with every billing row in editable columns. ![Edit Meter Details table for meter 2775715 08 showing Meter Number Provider DTE Energy Service Type Electric Deregulation Status Full Service Charges 1038.66 US Dollar Usage 4869.90 kWh Estimated dropdown and sync banner with Submit Changes button](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-edit-data.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=a7d086e24773a33d017b771aef10c776) Edit Meter Details table with usage and cost columns ![Edit Meter Details table right columns showing Estimated Start Date End Date Status Imported Data Origin Provider or System Accrual badge Accrual Status Replaced Reference upload and Actions history icon](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-edit-data-dates.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=2f92f5c9d3a9329f660a507ac89918c6) Edit Meter Details table with dates, status, and reference columns **3. Modify values** Click any cell to edit it. Common edits include correcting **Usage** or **Charges**, adjusting **Start Date** and **End Date**, and changing **Estimated** or **Deregulation Status**. **4. Submit changes** Click **Submit Changes** in the bottom-right corner. Changes sync to dashboards and charts after the next automatic update cycle. The editable columns match the meter's billing records, including charges, usage, dates, status, and reference uploads. For column definitions, see [Data table columns](/products/energ/reference/data-and-meter-fields#data-table-columns). For how **Provider** and **System Accrual** rows differ, see [Data origin values](/products/energ/reference/data-and-meter-fields#data-origin). > [!WARNING] > > Meter data changes reflect in all dashboards and charts after the automatic sync at the 25th minute of each hour. ### Upload a bill reference In **Edit Meter Details**, click the upload control in the **Reference** column for a row. The **Upload Files** dialog opens for that meter. ![Upload Files modal for Meter 2775715 08 with drag-and-drop zone Select files or drag them here and Cancel and Save Files buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-upload-files.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=6a009dddc41dc7bd151690dd70c83c26) Upload Files dialog for a meter billing row Select files or drag them into the zone, then click **Save Files**. ### Review version history Click the circular arrow icon in **Actions** to open **Activity Logs**. Expand a version to see the full snapshot EnerG stored for that row, including building context, charges, usage, and billing period type. ![Activity Logs Version History showing Version 1 with Meter Name 2775715 08 Provider DTE Energy Status IMPORTED Charges 1038.66 Usage 4869.90 kWh Start Date 04/14/2026 End Date 05/13/2026 and Created At timestamp](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-activity-logs.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=801768c1dc0fe5685b3becbb45bacd61) Activity Logs version history for a billing row ## Bulk import meter data Use bulk import when you need to add many billing rows at once from a spreadsheet template. **1. Open the meter detail** Select the meter from the list. **2. Open Bulk Import** Click the **three-dot** menu beside **+ Add Meter Data**, then select **Bulk Import**. ![Bulk Import modal titled Create new meter data using templates with Download Template link numbered steps and Select file or drag it here upload zone with Cancel and Submit buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-bulk-import.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=741a308f3da8bc7c17654b7a87812b0d) Bulk Import dialog with template download and file upload **3. Download and complete the template** Click **Download Template**. Add rows in the downloaded file using the same columns as **Edit Meter Details**, including meter number, provider, service type, charges, usage, dates, and status. **4. Upload and submit** Save the file, drag it into the upload zone or click to select it, then click **Submit**. New rows appear after processing and sync. > [!TIP] > > Match **Meter Number** and date ranges in the template to the open meter so EnerG maps rows correctly. ## Add new billing data You add billing records when a bill arrives outside the automated feed or when you need to fill a gap. **1. Open the meter detail** Select the meter from the list. **2. Click Add Meter Data** Click **+ Add Meter Data** in the top-right corner. The **Add Meter Data** panel opens. ![Add Meter Data side panel for meter 2775715 08 with Usage Cost Start Date End Date Deregulation Status Estimated dropdowns and Upload Files drag-and-drop zone with Cancel and Submit buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-add-data.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=9500a6d4027b8ddeeca95a5f0d1be402) Add Meter Data panel for a single billing period **3. Enter the reading** Provide **Usage**, **Cost**, **Start Date**, **End Date**, **Deregulation Status**, and **Estimated**. Upload a supporting file in **Upload Files** when you have a bill PDF. **4. Submit the entry** Click **Submit**. The new record appears in the **Data Table** tab and updates consumption charts after sync. ## Filter by year Use the `Choose Year` dropdown and the calendar icon in the top-right area of the meter detail to filter charts and tables to a specific year. The default view shows the current year. ## Include or exclude from metrics **1. Open meter properties** Select the meter, then click the **Properties** tab. **2. Edit and toggle inclusion** Click **Edit properties**. Switch **Include In Metrics** on or off according to your governance rules. **3. Save changes** Save so EnerG updates dashboards and compliance calculations. > [!NOTE] > > When two meters cover the same service, exclude one from metrics tracking to prevent double counting. ## Deactivate a meter **1. Open meter properties** Select the meter, then click the **Properties** tab. **2. Edit properties** Click **Edit properties**. **3. Set the service end date** Enter the final day the meter was valid in **Service End Date**. **4. Mark inactive** Change **Status** to inactive. **5. Save and confirm** Save. Verify that alerts and completeness views no longer expect reads from that meter. ## Interval meters Interval meters deliver granular usage, often hourly or every 15 minutes. You view interval data on the **Interval Data** tab when the meter has interval feeds. Chart sub-daily patterns on [Building Energy — Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends). > [!TIP] > > Align interval meters to the same service types as your billing meters so reconciliation reports stay straightforward. ## Next steps > [card] [Building information](/products/energ/buildings/building-information) > > Configure occupancy, exclusions, and envelope data for this site. > [card] [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows) > > Set energy, water, and waste baseline windows for this building. > [card] [Building data sources](/products/energ/buildings/data-sources) > > Review data sources scoped to this building. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Analyze usage and cost dashboards for this building. > [card] [Meter comparisons](/products/energ/data-quality/meter-comparisons) > > Validate utility bills against interval data. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how bills, interval reads, and calendarization work. > [card] [Data and meter fields](/products/energ/reference/data-and-meter-fields) > > Look up meter columns, data table columns, and status values. # Baselines and weather normalization Source: https://docs.kodelabs.com/products/energ/concepts/baselines-and-weather-normalization What baselines are in EnerG, how long they should run, and how weather normalization separates real savings from weather swings A **baseline** is a fixed historical reference window you measure future usage against. Weather normalization adjusts that comparison for hot and cold years. Together they let you claim savings that reflect operations, not weather. This page explains both concepts. To create baselines, see [Baseline analysis configurations](/products/energ/analytics/baseline-portfolio-configurations). For parameter definitions, see [Calculations and parameters](/products/energ/reference/calculations-and-parameters#weather-normalization). ## What a baseline is A baseline captures a period of stable, well-metered operation. EnerG compares later usage against it for savings, intensity, and compliance reporting. You set baselines at two levels. * **Portfolio configurations** train weather-normalized models across many buildings at once. * **Building windows** set energy, water, and waste reference periods for one site. ## Baseline length Choose a one-year or two-year window based on data stability and reporting policy. | Length | When to use it | | - | - | | 12 months | Standard reporting; reacts faster to operational change | | 24 months | Smooths anomalies; averages duplicate calendar months | Each category needs at least 12 consecutive months of complete billed data before EnerG accepts a baseline. Partial months or missing commodities disqualify the window until you repair the data. > [!WARNING] > > A baseline built on incomplete data biases every savings number that follows. Close gaps before you finalize a window. ## Why weather matters Raw year-over-year comparisons punish cold winters and reward mild ones. A building can run efficiently and still post higher usage in a harsh year. **Weather normalization** removes that noise. EnerG trains a regression model that relates usage to degree days (Degree days measure how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand.), then adjusts actual usage to a normal-weather equivalent. ## Degree days and base temperatures Degree days measure how far outdoor temperature departs from a base temperature each day. * **Heating degree days (HDD)** accumulate when it is colder than the heating base. * **Cooling degree days (CDD)** accumulate when it is warmer than the cooling base. Base temperatures often sit near 65 °F. EnerG pulls them from [Building information](/products/energ/buildings/building-information) or lets you set custom values per configuration. ## How normalized comparisons read A weather-normalized configuration produces four usage figures you compare on the [Baseline analysis overview](/products/energ/analytics/baseline-portfolio-overview). | Figure | Meaning | | - | - | | Baseline usage | Usage from the baseline window | | Actual usage | Measured usage in the reporting period | | Weather normalized usage | Actual usage adjusted to normal weather | | Expected usage | Usage the model predicts for the reporting weather | Model fit reports as an R-squared value. Configurations below your tolerance flag as low correlation and need review before you trust the numbers. Quiz Operations did not change, but a harsh winter pushed raw usage above last year. Leadership asks whether efficiency got worse. Which reading best separates weather from operations? ## Next steps > [card] [Create baseline configurations](/products/energ/analytics/baseline-portfolio-configurations) > > Train weather models and set building baseline windows. > [card] [Energy modeling](/products/energ/concepts/energy-modeling) > > See how baselines feed M\&V savings and forecasts. > [card] [Calculations and parameters](/products/energ/reference/calculations-and-parameters) > > Look up weather averages, R-squared tolerance, and base temperature settings. > [card] [Baseline analysis overview](/products/energ/analytics/baseline-portfolio-overview) > > Compare baseline, actual, and normalized usage across the portfolio. # Benchmarking and intensity metrics Source: https://docs.kodelabs.com/products/energ/concepts/benchmarking-and-intensity How EnerG normalizes energy, water, and carbon by area to rank buildings fairly across a portfolio Benchmarking compares buildings of different sizes on a fair basis. EnerG normalizes usage by area, then ranks and colors buildings by percentile. This page explains the intensity metrics and how rankings work. To use the ranking view, see [Portfolio Home](/products/energ/analytics/benchmarking). ## Why normalize by area Total usage favors small buildings and penalizes large ones. A tower always uses more energy than a branch office, even when the tower runs more efficiently. Intensity metrics divide usage by floor area. A small site can use less total energy and still rank worse per square foot. Normalization is what makes cross-building comparison meaningful. ## The three intensity lenses Portfolio Home ranks buildings through three metric lenses. | Metric | Definition | | - | - | | EUI (Energy Use Intensity: annual energy divided by conditioned floor area.) | Annual energy divided by conditioned area, after fuels convert to a common unit | | WUI (Water Use Intensity: water consumption normalized by floor area or another denominator.) | Annual water divided by area or another relevant denominator | | GHG | Greenhouse gas emissions, tied to area, occupancy, or revenue by your reporting standard | All three lenses share the same layout. Only the metric labels and ranking logic change. ![EnerG Portfolio Home with EUI selected, building list, map with pins, KPI cards, and a Building Rankings bar chart colored by performance](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-home-portfolio-eui.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=c4d2e34a490262b9fdc0d936b380ed24) Portfolio Home ranking buildings by EUI with a performance-colored bar chart ## How rankings and percentiles work EnerG ranks every qualifying building by the active metric, then colors it by percentile band. | Band | Percentile | | - | - | | Green | Top 25% | | Yellow | 25–50% | | Orange | 50–75% | | Red | 75–100% | | Blue | No ranking (insufficient data) | Lower intensity is better, so top performers sit in the green band. The same colors appear on the map, the ranking chart, and building cards. ## Completeness sets who qualifies Benchmarking only scores buildings that meet your completeness threshold. Buildings below it show **No Ranking** until coverage recovers. This prevents a building with missing bills from posting a misleading intensity. See [Data completeness](/products/energ/concepts/data-completeness) for how the gate works. ## Next steps > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Rank buildings and filter by EUI, WUI, and GHG. > [card] [Data completeness](/products/energ/concepts/data-completeness) > > Understand the coverage gate that decides which buildings rank. > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > See how GHG intensity ties to scopes and emission factors. > [card] [Baselines and weather](/products/energ/concepts/baselines-and-weather-normalization) > > Compare intensity against a weather-normalized reference. # Budgets and capital planning Source: https://docs.kodelabs.com/products/energ/concepts/budgets-and-capital-planning How EnerG models energy budgets, accruals, and variance, and how capital measures and scenarios project savings EnerG connects two financial workflows: annual energy budgets and capital investment planning. Budgets track plan against actual spend. Capital planning models the savings that reshape future budgets. This page explains the shared concepts. To build these, see [Budget planning](/products/energ/finance/budget-planning) and [Capital planning](/products/energ/sustainability/capital-planning). ## Predicted, actual, and variance A budget sets a planned cost for each month. As bills arrive, EnerG compares plan against reality. | Term | Meaning | | - | - | | Predicted | Estimated year-end spend based on current trends | | Actual | Billed cost to date for the selected year | | Variance | Difference between budget and actual, in value and percent | Variance shows a dash until an active budget exists for the period. ## Accruals Accruals (Accruals estimate usage or cost for months that lack final bills.) estimate cost for periods without final utility bills. They borrow prior-year shapes, apply calendarization, and close month-end gaps. Treat accruals as placeholders. EnerG trues them up when utilities post final reads. Turn accruals on for month-end reporting and off for a billed-only view during audits. ## Budget models A budget model trains on a reference period to predict future consumption and cost. Three planning methods drive the values. | Method | How it builds values | | - | - | | Smart Generation | Projects from historical usage and weather | | Reference Year | Copies a chosen baseline period | | Manual Entry | Direct monthly input | Smart Generation and Reference Year draw on a trained model from [Model configuration](/products/energ/finance/budgets). Only one budget should be active per period. ## Measures, curves, and scenarios Capital planning models conservation investments before you fund them. * A **conservation measure** is one project with savings, capital cost, and incentives. * A **distribution curve** spreads annual savings across months, weighted by cooling, heating, or a flat profile. * A **scenario** bundles measures into a funding package with priority and dates. ![Measure Creation page showing a Measures table with savings, cost, and payback columns and a Distribution Curves table with cooling, flat, and heating factors](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-measure-creation.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3155f483043f17f917b549d70e2f487b) Measure creation with a measures table and distribution curves ## How savings reach the budget Measures move through a lifecycle: **Planning**, **Implementation**, then **Operations**. The **operation date** marks when savings first count. Scenarios project savings on the capital planning roadmap toward a target year. When a measure reaches operations, you connect it to an [M\&V model](/products/energ/energy-modeling/mv-models) so verified savings match the plan. You also pull measures into a budget's capital planning step so the plan reflects expected reductions. > [!NOTE] > > Treat simple payback as a planning signal. Confirm capital cost, incentives, and savings against your funding rules before you activate a budget. Quiz It is month-end and several utility bills have not posted. Finance needs a close view now, but Audit wants a billed-only view next week. How should you treat accruals in EnerG? ## Next steps > [card] [Budget planning](/products/energ/finance/budget-planning) > > Build, review, and activate an annual building budget. > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Create measures, curves, and scenarios for one building. > [card] [Energy modeling](/products/energ/concepts/energy-modeling) > > See how M\&V verifies the savings you plan. > [card] [Calculations and parameters](/products/energ/reference/calculations-and-parameters) > > Look up distribution curves and accrual behavior. # Data sources and meters Source: https://docs.kodelabs.com/products/energ/concepts/data-and-meters How utility bills, interval reads, and meters feed EnerG analytics, and why calendarization matters EnerG runs on two data streams: monthly utility bills and high-frequency interval reads. This page explains how those streams enter the product, how meters organize them, and why EnerG calendarizes bills before it compares periods. For the steps to connect a feed, see the connector how-tos: [Arcadia](/products/energ/data-sources/arcadia), [CSV uploads](/products/energ/data-sources/csv-uploads), [Manual entry](/products/energ/data-sources/manual-entry), and the [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## EnerG and KODE OS Use EnerG for utility bills, bill-led reporting, compliance, and sustainability planning. Use KODE OS (KODE OS is the platform that connects building systems, apps, and data across your portfolio.) for submeters, interval data, and operational insight. Many portfolios need both. Bills and interval reads stay separate. Site meters and equipment trends do not replace utility bills for portfolio EUI, cost rollups, or accruals. ## Two data streams Most EnerG dashboards, rankings, and accruals run on **utility billing data**: the monthly statements your electric, gas, and water providers issue. Automated connections retrieve those bills on a schedule. EnerG imports interval meters when you need granular charts, forecasting, or Option B M\&V. Interval reads are normalized before analytics use them. See [Interval data normalization](/products/energ/concepts/interval-data-normalization). | Data type | Typical source | Primary use in EnerG | | - | - | - | | Utility bills | Arcadia, CSV, manual entry | Portfolio Home, dashboards, targets, budgets, alert center | | Interval meters | KODE OS data source | [Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends), forecasting, Option B M\&V | | Waste tickets | Manual or bulk upload | Waste dashboards and diversion metrics | ## Data sources A **data source** is any path that brings utility or meter data into EnerG. You manage sources once per portfolio and reuse them across buildings. | Method | Purpose | | - | - | | [Arcadia](/products/energ/data-sources/arcadia) | Automated utility data via credential-based connections | | [CSV uploads](/products/energ/data-sources/csv-uploads) | Load historical totals from spreadsheets | | [Manual entry](/products/energ/data-sources/manual-entry) | Create meters and enter readings manually | | [KODE OS data source](/products/energ/data-sources/kode-os-data-source) | Interval meters for analytics and M\&V | See the full comparison on [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ## Accounts, meters, and statements Utility data lands in three related layers. * **Meters** measure usage at physical or virtual service points. * **Accounts** group one or more meters under a single payer. * **Statements** (bills) summarize meter-level usage, billing periods, rates, and total costs for an account. In practice: meters roll up to accounts, and accounts produce statements. Example: a mixed-use building may have five electric meters. Three suite meters bill to individual accounts. Two common-area meters share one owner account. Each account receives its own monthly statement. When you connect a utility account, EnerG can capture all meters in that login. Statements may arrive per meter or combined, depending on the provider. ## Service types and commodity groups **Service types** describe what flows through a meter. EnerG groups them into three **commodity groups** for portfolio reporting. | Group | Includes | | - | - | | Energy | Electric plus fuels such as natural gas, steam, and oil | | Water | Potable and irrigation water | | Waste | Waste streams tracked by disposal method | Fuels convert to a common energy unit before EnerG rolls them into portfolio energy totals and EUI. For the full service-type list, see [Data and meter fields](/products/energ/reference/data-and-meter-fields#service-types). ## Meters A **meter** is the utility-assigned or platform-tracked measurement point that records resource usage for a service location. Each meter has service start and end dates that control which bills count toward a building. Meters differ by scope and by feed. | Distinction | Values | Meaning | | - | - | - | | Scope | Main meter, submeter | Whole-site boundary versus a load below it | | Feed | Utility, interval, both | Monthly bills, high-frequency reads, or both on one meter | **Utility bill meters** settle on monthly billing periods. **Interval meters** record usage every hour or every 15 minutes for load shapes, forecasting, and M\&V. ![Meters page grouped by Energy Electric Lighting Natural Gas and Steam with a table showing Meter Level Service Type Unit Status Completeness Data Source and Provider Name columns](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meters-list.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=b1c4f8061cae61f3e15c19f56084c025) Building meters grouped by service category with feed badges For field definitions such as meter status, level, and data origin, see [Data and meter fields](/products/energ/reference/data-and-meter-fields). To manage meters, see [Building meters](/products/energ/buildings/meters) and [Portfolio meters](/products/energ/analytics/portfolio-meters). ## Calendarization **Calendarization** spreads each billing period across calendar months using average daily consumption. It normalizes irregular bill windows so January always means January. A bill that runs January 13 to February 11 splits its usage across both months by daily rate. EnerG then reports a clean January value and a clean February value. ![Meter Overview tab showing Monthly Consumption per Billing Period and Calendarized Monthly Consumption charts in kWh](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-buildings-meter-overview-metric-usage.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=8d1009a06a981c601365a088d9605849) Raw billing periods next to calendarized monthly consumption for one meter You rely on calendarization for year-over-year comparisons, accounting closes, and any dashboard that must align to calendar months. ## How data flows Portfolio settings and data sources shape what each building can use. Building-level meter work rolls up to portfolio dashboards, rankings, and alerts. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR A["Utility provider"] -->|"bills"| B["Data source"] K["KODE OS points"] -->|"interval reads"| B B --> M["Meters"] M --> C["Calendarization"] C --> D["Dashboards, rankings, budgets"] M --> I["Interval Trends, M&V, forecasting"] ``` Quiz Finance needs portfolio Energy Use Intensity, accruals, and budget variance for the monthly close. Operations also wants 15-minute load shapes for one chiller plant. Which data approach is correct? ## Next steps > [card] [Data completeness](/products/energ/concepts/data-completeness) > > See how EnerG scores billed coverage and why gaps drop a building from benchmarking. > [card] [Interval data normalization](/products/energ/concepts/interval-data-normalization) > > See how irregular interval reads become clean 15-minute values. > [card] [Data and meter fields](/products/energ/reference/data-and-meter-fields) > > Look up service types, units, meter states, and column definitions. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Connect Arcadia, uploads, manual entry, and interval feeds. # Data completeness Source: https://docs.kodelabs.com/products/energ/concepts/data-completeness How EnerG scores billed coverage, why gaps and overlaps lower the score, and how completeness gates benchmarking **Data completeness** is a score from 0% to 100% that measures billed coverage from each meter's service start through today. It is the trust signal behind every EnerG metric. This page explains how the score works and what moves it. To fix gaps, see [Data completeness](/products/energ/data-quality/data-completeness) in the Data Quality section. For the color legend and status values, see [Data and meter fields](/products/energ/reference/data-and-meter-fields#data-quality-legend). ## What the score measures Completeness compares the bills EnerG expects against the bills it has. It counts every month from a meter's service start date to the current date. Missing bills, gaps, and overlaps lower the score. Complete, non-overlapping coverage raises it. | Signal | Effect on score | | - | - | | Complete billing period | Raises coverage | | Gap (missing expected bill) | Lowers coverage | | Overlap (duplicate or double-counted period) | Lowers coverage | | Delivery-only or supply-only bill | Partial coverage | ## Meter, building, and portfolio scoring Completeness rolls up in three layers. * **Meter level** scores one meter from its service start to today. * **Building level** aggregates meter scores across all included meters for the site. * **Portfolio level** averages building coverage for the KPI on Portfolio Home. A meter excluded from metrics does not drag down the building score. Confirm the `Include In Metrics` setting when a meter should or should not count. ![Meter data quality timeline showing complete green segments and a gap where an expected bill is missing](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-completeness-meter-gap-timeline.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=cadcc4fc870992ee8dd8277db4eed649) Meter bills data quality timeline with complete periods and gaps ## Why completeness gates benchmarking EnerG only ranks buildings that meet your organization's completeness threshold. Buildings below the threshold appear with **No Ranking** until coverage recovers. This rule protects peer comparisons. A building with three missing months would post an artificially low EUI and distort rankings. Completeness holds it out until the data is trustworthy. The same rule applies before you set baselines, train models, or publish reports. Each needs 12 consecutive months of complete data to qualify. ## Common causes of low coverage * A utility credential failed, so new bills stopped arriving. * A meter was assigned late, so early months never loaded. * A provider issued overlapping or corrected bills. * A manual meter has no readings for recent months. Each cause has a fix in the [gap investigation workflow](/products/energ/data-quality/data-completeness#investigate-and-fix-gaps). Quiz A building is missing three months of utility bills. Its Energy Use Intensity looks unusually low, and someone wants it ranked on Portfolio Home anyway. What should EnerG do? ## Next steps > [card] [Fix completeness gaps](/products/energ/data-quality/data-completeness) > > Review a meter timeline and work through the gap investigation steps. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Review how bills and interval reads enter EnerG and roll into meters. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Triage billing gaps, overlaps, and late bills across the portfolio. > [card] [Benchmarking and intensity](/products/energ/concepts/benchmarking-and-intensity) > > See how completeness thresholds affect EUI, WUI, and GHG rankings. # Emissions accounting Source: https://docs.kodelabs.com/products/energ/concepts/emissions-accounting How EnerG tracks GHG scopes, location- and market-based methods, RECs, offsets, and emission factors EnerG converts energy and activity data into greenhouse gas emissions using scopes, methods, and factors. This page explains the accounting model behind the emissions dashboards. To manage emissions data, see the portfolio [Emissions overview](/products/energ/analytics/portfolio-emissions-overview) and its related pages. For field schemas, see [Emissions reference](/products/energ/reference/emissions-reference). ## GHG scopes EnerG organizes emissions by the greenhouse gas scopes your portfolio tracks. | Scope | Source | EnerG coverage | | - | - | - | | Scope 1 | Direct combustion and losses | On-site fuels, fleet fuel, fugitive refrigerant loss | | Scope 2 | Purchased energy | Electricity and district energy, reported two ways | | Scope 3 | Indirect upstream and downstream | T\&D losses, waste, water and wastewater, leased-asset energy where meters support it | Scope 1 combines stationary combustion with [fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions) and [fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). EnerG focuses on building and portfolio utilities. It does not cover every possible Scope 3 category, such as purchased goods, business travel, or investments. Your reporting boundaries and disclosure choices remain your responsibility. ## Location-based and market-based Scope 2 EnerG reports Scope 2 emissions two ways. These totals are never mixed into one number. | Method | Basis | | - | - | | Location-based | The average grid emission factor for the building's region | | Market-based | Contractual instruments such as RECs, guarantees of origin, and green tariffs | Report either or both when your program requires it. Market-based totals fall as you allocate renewable instruments. Location-based totals track the grid. ![Emissions Overview showing Total Energy, Scope 2 Market-based, Scope 2 Location-based, a GHG Emissions by Scope chart, and a metrics table](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-emissions-overview.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=26b815ab2616c1dbf6b85efcf5068560) Building emissions overview with Scope 2 market-based and location-based cards ## RECs and covered load A renewable energy certificate (REC) (Renewable energy certificate: a tradable attribute representing renewable generation that can be allocated and retired.) represents renewable generation you can allocate to buildings and retire against emissions. For market-based electricity, EnerG splits use into: * **Covered** — matched to your renewable contract or certificates (often zero emissions per kWh) * **Uncovered** — the remainder, which still uses a grid or residual-mix factor Example: a building uses 1,000 megawatt-hours in a year. RECs cover 800 megawatt-hours. The uncovered factor is 0.35 kg CO₂e per kWh. | Method | Result | | - | - | | Location-based | 1,000 × 0.35 = 350 tonnes CO₂e | | Market-based | 200 × 0.35 = 70 tonnes CO₂e | You record instruments as [volume contracts](/products/energ/analytics/portfolio-emissions-contracts), then allocate and retire volume by reporting year. * **Residual emissions** are emissions before offsets. * **REC avoided** reductions come from retired certificates. * **Onsite avoided** reductions come from on-site generation such as solar. ## Emission factors An **emission factor** converts activity into carbon: Emissions = Usage × Emission factor. Each factor carries a methodology, GHG scope, service type, and geography or grid. Only active factors apply to reports. Manage them in the [emission factors library](/products/energ/analytics/portfolio-emissions-emission-factors). ### Where default factors come from EnerG starts with published datasets from recognized authorities. Your organization can keep these defaults or set custom factors. | What you measure | Typical default sources | | - | - | | Electricity (grid average) | EPA eGRID (US), national inventory data, IEA, UK DEFRA | | Electricity (market-based uncovered) | European residual mix (AIB) in the EU; grid average elsewhere | | Natural gas and other fuels | EPA Emission Factors Hub, UK DEFRA | | Refrigerants | IPCC GWP values and regional tables where applicable | | Waste | EPA WARM and national waste inventories | | Water and wastewater | Regional water-energy models; DEFRA as a fallback | | T\&D losses | National or regional loss rates combined with the grid factor | Factors are versioned by year so historical reports stay aligned with the standards for that period. ### Which factor applies When EnerG calculates emissions for a reading, it picks a factor in this order: 1. **Building-specific factor** — assigned for that building and utility type 2. **Portfolio default** — your organization standard for all sites 3. **System default** — the official library for that region and year In the app you may see labels such as Default (official library), Custom (portfolio), or Override (building). You can create custom factors for electricity, fuels, refrigerants, waste, and T\&D. Reporting years can be locked so factor edits do not silently rewrite history. For fugitive events, EnerG multiplies refrigerant quantity lost by the refrigerant's global warming potential (GWP) (Global warming potential: the multiplier that converts a refrigerant quantity into CO2 equivalent.) to produce CO₂e. ## Compliance-oriented exports EnerG produces structured exports through [Report Builder](/products/energ/finance/reporting) for consumption, cost, GHG, and completeness. Use those outputs as the system of record for disclosure prep. EnerG does not complete third-party sustainability filings end to end. You export metrics from EnerG, then finish entry and submission in your disclosure tools. Quiz Your building buys grid electricity and also retires renewable energy certificates (RECs) for most of that use. Leadership wants one Scope 2 number that reflects both the local grid and your REC purchases. What should you do in EnerG? ## Next steps > [card] [Portfolio emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review scope totals, offsets, and the metrics table. > [card] [Emission factors library](/products/energ/analytics/portfolio-emissions-emission-factors) > > Manage factors that drive carbon calculations. > [card] [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts) > > Create, allocate, and retire REC volume. > [card] [Emissions reference](/products/energ/reference/emissions-reference) > > Look up scope columns, factor sources, and record fields. # Energy modeling and M&V Source: https://docs.kodelabs.com/products/energ/concepts/energy-modeling How EnerG uses IPMVP options, adjusted baselines, and regression models to verify savings and forecast usage Energy modeling links meter data to savings verification and forecasts. EnerG follows the International Performance Measurement and Verification Protocol so savings stay comparable across projects. This page explains the methods; the how-tos train the models. To build models, see [Create an M\&V model](/products/energ/energy-modeling/mv-models) and [Forecasting](/products/energ/energy-modeling/forecasting). ## What M\&V confirms Measurement and Verification (M\&V) (Measurement and Verification confirms that savings from energy projects are real, using agreed methods and data.) confirms that reported savings reflect real performance. It documents savings for audits, incentives, and internal governance. EnerG trains a model on a baseline period, then compares later usage against the model's **adjusted baseline**: what the building would have used without the measure, under the same conditions. ## IPMVP options IPMVP (The International Performance Measurement and Verification Protocol defines standard approaches for quantifying energy savings.) offers several options. EnerG supports two. | Option | Boundary | When to use it | | - | - | - | | Option B | Meter or system level | A measure targets specific equipment with dedicated metering | | Option C | Whole building | A retrofit or program is best measured at billing boundaries | Option B isolates a single system when metering separation is strong. Option C reads the whole-building signal when boundary-level bills represent performance. ## Meter types for modeling You build models from two meter types. * **Utility bill meters** provide monthly granularity from billing periods. * **Interval meters** provide hourly or 15-minute granularity for finer load shapes. Pick the meter type that matches your data and the savings story you need to tell. Interval models capture time-of-day patterns that monthly bills cannot show. ## Drivers and model fit Models regress energy against drivers so you separate real savings from noise. Common drivers include weather (degree days), occupancy, and interval-of-week patterns. EnerG reports fit with three accuracy metrics. | Metric | What it measures | | - | - | | R-squared | Share of variation the model explains | | CV-RMSE | Scatter of predictions around actuals | | MAPE | Average percent error | A model that falls below your thresholds flags as not acceptable. Widen the baseline, adjust variables, or improve meter completeness before you rely on it. See [Calculations and parameters](/products/energ/reference/calculations-and-parameters#model-accuracy) for typical thresholds. ## Forecasting Forecasting projects future consumption from trained models. It extends past performance forward using the drivers you trained, such as weather. You link forecasts to capital planning measures so projected use supports funding decisions and scenario work. Quiz You retrofit lighting across a whole building and only have utility bill meters at the building boundary. You need Measurement and Verification that follows IPMVP practice in EnerG. Which option fits? ## Next steps > [card] [Create an M\&V model](/products/energ/energy-modeling/mv-models) > > Configure meters, baselines, and drivers to train a savings model. > [card] [M\&V analysis](/products/energ/energy-modeling/mv-analysis) > > Read savings, charts, and accuracy metrics after a run completes. > [card] [Forecasting](/products/energ/energy-modeling/forecasting) > > Project one to 12 months of consumption from trained models. > [card] [Baselines and weather](/products/energ/concepts/baselines-and-weather-normalization) > > Review how baseline windows and weather models set the reference. # Interval data normalization Source: https://docs.kodelabs.com/products/energ/concepts/interval-data-normalization How EnerG turns irregular interval meter readings into clean 15-minute and daily values with quality labels Interval meters often report at irregular times, in mixed units, with gaps and glitches. **Normalization** converts those readings into a uniform dataset: one row per meter per 15-minute or daily interval, in standard units, with quality labels on every row. This page explains why that process matters and what you get from it. Normalized interval data powers [Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends), [M\&V](/products/energ/energy-modeling/mv-models), and [Forecasting](/products/energ/energy-modeling/forecasting). Connect the feed through the [KODE OS data source](/products/energ/data-sources/kode-os-data-source). For label definitions, see [Interval normalization labels](/products/energ/reference/interval-normalization-labels). ## Why normalization matters Raw interval data is messy. Without cleanup, charts and totals mislead. | Problem | Impact without normalization | | - | - | | Irregular timestamps | You cannot compare meters or aggregate reliably | | Mixed units | 1 kWh is not 1 megawatt-hour; calculations break | | Missing readings | Gaps in charts and incomplete totals | | Duplicate entries | Consumption is counted more than once | | Sensor glitches | Impossible spikes or dips skew analysis | | Invalid configurations | Wrong conversions and ambiguous results | ## What goes in and what comes out **Input:** Irregular readings from accumulators, sensors, and pulse meters, with different units, gaps, duplicates, and outliers. **Output:** A uniform dataset with: * One row per meter per 15-minute interval (and a daily consumption row) * Standardized units by meter type * Quality labels that show how each value was produced or why it is empty The pipeline runs daily for each building. Each run processes the previous day so raw readings are complete before normalization starts. ## Virtual points For each meter, normalization produces three virtual points. | Virtual point | Interval | Description | | - | - | - | | Consumption (15-min) | 15 minutes | Energy or volume consumed in the interval | | Rate (15-min) | 15 minutes | Average power or flow during the interval | | Consumption (Daily) | 1 day | Total energy or volume for the day | ### Output units by meter type | Meter type | Consumption unit | Rate unit | | - | - | - | | Electric | kWh | kW | | Water | gal | gal/min | | Natural gas | ft³ | ft³/h | | Steam | lbm | lbm/h | | Energy (chilled or hot water) | kBtu | kBtu/h | ## How the process works Normalization follows a fixed sequence. 1. **Validate meter configuration** — Flag duplicate fields, cooling and heating conflicts, and invalid units before processing. 2. **Clean raw readings** — Drop nulls and duplicates. Remove negative values, zero accumulators, and spike or dip outliers. 3. **Standardize units** — Convert every reading to the target unit for that meter type. 4. **Align to 15 minutes** — Map irregular timestamps to a uniform grid. Accumulators become interval consumption by differencing. Sensors convert rate to consumption. 5. **Apply physical limits** — Nullify values that exceed meter-type limits for a 15-minute window. 6. **Select the best field** — When a meter has multiple fields, prefer total accumulators over differentials and sensors. 7. **Fill short gaps** — Linear interpolation covers gaps up to two hours. Longer gaps stay empty. 8. **Label every row** — Attach configuration, validation, and interpolation labels so you can trust or investigate each value. Meters with no raw data still appear in the output with empty values and a missing-data label. Nothing is silently dropped. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR A["Raw interval readings"] --> B["Validate and clean"] B --> C["Standardize and resample"] C --> D["Label quality"] D --> E["15-min and daily virtual points"] ``` ## Data quality labels Every normalized row carries a `labels` dictionary. Empty braces `{}` mean clean measured data. | Category | What it covers | | - | - | | `data_quality` | Meter-level configuration issues | | `validation` | Row-level data problems such as missing readings or outliers | | `interpolation` | How a gap or timestamp was filled | | `field_used` | Which source field supplied the value | Treat configuration and validation labels as signals to fix mapping or sensors. Treat interpolation labels as estimates for short gaps. Full definitions live on [Interval normalization labels](/products/energ/reference/interval-normalization-labels). ## Next steps > [card] [Interval normalization labels](/products/energ/reference/interval-normalization-labels) > > Look up virtual point fields, limits, and quality label meanings. > [card] [KODE OS data source](/products/energ/data-sources/kode-os-data-source) > > Connect interval meters that feed normalization. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > See how bills and interval reads fit together in EnerG. > [card] [Meter comparisons](/products/energ/data-quality/meter-comparisons) > > Compare utility bills against interval totals after data is clean. # Alert center Source: https://docs.kodelabs.com/products/energ/data-quality/alert-center Monitor and resolve data quality alerts for utility meters across your portfolio `Alert Center` lists data quality issues for utility meters so you can fix gaps (A period where an expected bill is missing.) before reporting drifts in EnerG. You work alerts at portfolio scope and can filter by building, alert type, priority, and status. > [!NOTE] > > Alert Center behaves like **fault monitoring for utility bills**: it flags late statements, gaps, overlaps (Two bills that cover the same days.), and duplicates from bill start and end dates. Alerts are **passive** in the product—you review them in EnerG rather than receiving the same real-time notifications you may get from KODE OS FDD. Your team or KODE Labs can configure day thresholds for each alert type. ## Navigate to Alert Center You reach `Alert Center` in two ways. * **Portfolio view**: Click `Alert Center` in the left sidebar to review the full backlog. See [Portfolio and building navigation](/products/energ/get-started/navigation#portfolio-view). * **Building card**: Click the alert count on a building card in the `Home` page benchmarking view to open alerts filtered to that site. ## Understand the Alert Center layout The `Alert Center` page opens with filter dropdowns at the top: `Buildings`, `Alert Type`, `Priority`, and a `Status` filter defaulting to **Open**. Three KPI cards below the filters show counts by priority level. ![Alert Center page with Buildings, Alert Type, Priority, and Open status filter dropdowns, High Priority count of 2318, Medium Priority of 2401, and Low Priority of 1422, followed by alert type rows including Billing Period Gap at 1292, Due Date After Expected at 284, Duplicate Bill Detected at 62, Due Date Before Period End at 11, Long Billing Period at 270, Missing Utility Bill at 2245, Overlapping Billing Periods at 825, and Short Billing Period at 1152](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-quality-alert-center-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=e779273c0336ba2669481a1330d7fbbb) Alert Center showing filter dropdowns, priority KPI cards, and alert type rows with counts Below the KPI cards, alert types appear as expandable rows. Each row shows the alert name, a severity icon (red for high, orange for medium, blue for low), and a count. Click the chevron on any row to expand it and see affected buildings and meters. For what each alert type means, see [Alert types](/products/energ/reference/reporting-and-alerts#alert-types). ## Alert priority and status **Priority** values are High, Medium, and Low. High-priority alerts appear with a red icon and should be resolved first. **Status** values are: * **Open** -- the issue needs attention * **Investigating** -- someone is actively reviewing the issue * **Acknowledged** -- the team is aware but a longer fix is needed * **Closed** -- the issue is resolved The default view filters to **Open** alerts. Clear or adjust the status filter when you need acknowledged items or closed history for an audit. ## Inspect an alert Click the chevron on an alert type row to expand it. The expanded view shows a table with columns for `Building Name`, `Meter Name`, `Start Date`, `Tail Gap Days`, `Status`, `Activity Log`, and `Take Action`. ![Alert Center with the Missing Utility Bill row expanded, showing a table with Building Name, Meter Name, Start Date, Tail Gap Days, Status set to Open, Activity Log link, and a Take Action link for the Headquarters building](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-quality-alert-detail.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=40afa5180c71b2f29d9f76683d48bf3c) Expanded Missing Utility Bill alert showing affected meters and resolution actions Click `Take Action` on any row to open the resolution panel for that specific alert. ## Resolve an alert The resolution panel shows the meter name, missing period dates, provider, account number, and connection status. Four resolution options appear. **1. Choose an alert** Expand an alert type, then click `Take Action` on the row you want to address. ![Missing Utility Bill detail panel showing meter name, missing period dates, provider DTE Energy, account number, Connection Success status, and action options for Upload Invoice, Enter Manually, and Deactivate Meter, with Close, Force Close, Acknowledge, and Save buttons at the bottom](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-quality-alert-action.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=4d53d85ba7b244710fa2d94c223aa9fd) Alert detail panel with meter info, provider status, and resolution action buttons **2. Pick a resolution path** Choose one of the resolution actions: * **Upload Invoice** -- drag and drop a PDF bill to fill the gap through OCR extraction * **Enter Manually** -- type start date, end date, usage, and cost for the missing period * **Deactivate Meter** -- set a service end date and mark the meter inactive when the service truly ended * **Navigate to Meter** -- open the meter record to inspect intervals and history before deciding **3. Close or acknowledge** Use the buttons at the bottom of the panel: * **Close** -- dismiss the panel without changes * **Force Close** -- remove the alert from the active list when no further work applies * **Acknowledge** -- keep the alert visible while you coordinate a longer fix * **Save** -- persist your changes > [!TIP] > > Alerts can auto-close when the underlying data issue clears. Verify bills and mappings before you force-close manually. ## Configure alert thresholds Set the day-based alert threshold (The number of days that must pass before EnerG raises an alert.) that decides when EnerG raises each alert type. Threshold changes apply at portfolio scope. **1. Open the configuration panel** Click `Configure Alerts` in the top-right corner of the `Alert Center` page. ![Configure Alerts panel showing editable threshold fields for Billing Gap at 5 days, Overlapping Days at 1 day, Short Billing Period at 10 days, Long Billing Period at 10 days, Delayed Due Date at 60 days, and Missing Utility Bill at 45 days, with Close and Save buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-quality-alert-configure.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=8f72379a04c340e4fade7d9249b83c44) Configure Alerts panel with editable day-based thresholds for each alert type **2. Set day thresholds** Enter the day threshold for each alert type, such as `Billing Gap` or `Missing Utility Bill`. For every threshold and what it controls, see [Alert thresholds](/products/energ/reference/reporting-and-alerts#alert-thresholds). **3. Save the thresholds** Click `Save` to apply the changes across the portfolio. > [!NOTE] > > Align thresholds with your data governance policy before you widen tolerance. Loose thresholds can hide real gaps. ## Next steps > [card] [Data quality overview](/products/energ/data-quality/data-quality-overview) > > See how completeness, alerts, and meter comparisons fit together. > [card] [Data completeness](/products/energ/data-quality/data-completeness) > > Understand scoring windows, monthly meter logic, and benchmarking exclusions. > [card] [Meter comparisons](/products/energ/data-quality/meter-comparisons) > > Compare billed usage to interval readings after you clear blocking alerts. # Data completeness Source: https://docs.kodelabs.com/products/energ/data-quality/data-completeness Review meter timelines and upload missing bills to close data completeness gaps in EnerG Fix meter coverage gaps in EnerG before they skew analytics or benchmarking. This page walks you through reviewing a meter timeline and uploading the bills that raise its data completeness (A score from 0% to 100% that measures billed coverage from each meter's service start through today.) score. To learn how EnerG scores coverage and why gaps and overlaps lower it, see the [data completeness concept](/products/energ/concepts/data-completeness). ## Where you see completeness You view completeness in several places throughout EnerG. * **KPI card on the Home page**: The **Data Completeness** card shows the portfolio-wide percentage on the [Portfolio Home](/products/energ/analytics/benchmarking) page. * **Building detail panel**: Each building's detail panel on **Home** shows a completeness score and trend chart. * **Data Quality report**: Open **Data Quality** from the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#data-quality) report menu for meter-by-meter coverage at the building level. * **Portfolio meters**: [Portfolio meters](/products/energ/analytics/portfolio-meters) lists monthly completeness percentages by account and meter. ## Review gaps on a meter Open [Building meters](/products/energ/buildings/meters), select a meter, then open the **Data Quality** tab. The **Bills Data Quality** chart shows how each day in the date range is classified. ![Meter detail Data Quality tab for 8365020 03 with Bills Data Quality timeline showing mostly Complete green segments and a light blue Gap segment with tooltip for Electric meter December 04 2025 to December 05 2025](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-completeness-meter-gap-timeline.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=cadcc4fc870992ee8dd8277db4eed649) Bills Data Quality chart with a gap segment highlighted Each segment is colored by coverage: a gap (A period where an expected bill is missing.) shows light blue and an overlap (Two bills that cover the same days.) shows yellow. For the full color legend, see [Data quality legend](/products/energ/reference/data-and-meter-fields#data-quality-legend). Hover a segment to read **Service Type**, **Meter**, **Segment**, and **Period** in the tooltip. Scroll below the chart for a table that alternates **Complete** rows (with **BILL** links and usage) and **Gap** rows (zero usage and no statement). ![Meter Data Quality table for 8365020 03 showing alternating Complete rows with BILL statement type and kWh usage and Gap rows with zero usage between billing periods](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-completeness-meter-gap-table.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=27922b48da61e942fa84f679e2423c9d) Data Quality table with Complete and Gap rows A **Gap** row between two **Complete** periods usually means EnerG expected a bill for those dates but none arrived. See [Building meters — Data Quality tab](/products/energ/buildings/meters#data-quality-tab) for column definitions and bill PDF links. ## Why gaps matter Buildings below your completeness threshold drop out of benchmarking until coverage recovers. For why this rule protects rankings, see [Why completeness gates benchmarking](/products/energ/concepts/data-completeness#why-completeness-gates-benchmarking). ## Investigate and fix gaps **1. Identify low-scoring buildings** Open [Portfolio Home](/products/energ/analytics/benchmarking) and check the **Data Completeness** KPI card. Click a building with a low score to review its detail panel. **2. Open the meter Data Quality tab** Go to [Building meters](/products/energ/buildings/meters), select the meter, and open **Data Quality**. Use the date range picker in the header to match the gap period. Confirm **Gap** segments on the chart and **Gap** rows in the table. **3. Diagnose the root cause** Match what you see to one of the causes below. Each cause points to the workflow that fixes it. **4. Upload bills or fix the source** When the gap is missing billing data, follow [Add new billing data](/products/energ/buildings/meters#add-new-billing-data) on the same meter detail page. Click **+ Add Meter Data**, enter usage and dates, and upload the bill PDF in **Upload Files** when you have it. For many gaps at once, use **Bulk Import** from the three-dot menu next to **+ Add Meter Data**. See [Bulk import meter data](/products/energ/buildings/meters#bulk-import-meter-data) for the Excel template workflow. **5. Confirm the gap closed** Return to the **Data Quality** tab after data syncs. **Gap** segments should turn **Complete**, and the building completeness score should rise on **Home**. > [!TIP] > > Revisit completeness on [Portfolio meters](/products/energ/analytics/portfolio-meters) or the building **Data Quality** report when you finish. ### Common gap causes > [accordion] Missing bills (no data from the provider for a period) > > **What you see:** Light blue **Gap** segments on the timeline and **Gap** rows with **0.00** usage in the table. > > **What to do:** Upload or enter the missing period on [Building meters — Add new billing data](/products/energ/buildings/meters#add-new-billing-data). If the provider should have sent the bill automatically, check [Arcadia](/products/energ/data-sources/arcadia) **Statements** or [Alert center](/products/energ/data-quality/alert-center) for ingestion errors first. > [accordion] Offline or stale data source credentials > > **What you see:** Gaps across many meters that share one utility account, often with no new **BILL** rows for weeks. > > **What to do:** Open [Arcadia](/products/energ/data-sources/arcadia) at the portfolio or building level, review **Credentials** status, and re-authenticate or refresh the connection. After statements flow again, gaps close without manual entry when ingestion succeeds. > [accordion] Incorrect service start or end dates > > **What you see:** Long **Gap** bars at the start or end of the timeline, or **Complete** periods that do not match when the meter was actually active. > > **What to do:** Open the **Properties** tab on [Building meters](/products/energ/buildings/meters#properties-tab) and correct **Date Became Active** and **Date Became Inactive**. EnerG recalculates expected days in the completeness window after you save. > [accordion] Meters not yet mapped to the building > > **What you see:** Low building completeness while the meter list looks healthy, or bills exist in the portfolio but not on this building's **Meters** page. > > **What to do:** Assign meters from [Arcadia](/products/energ/data-sources/arcadia), [CSV uploads](/products/energ/data-sources/csv-uploads), [Manual entry](/products/energ/data-sources/manual-entry), or [KODE OS](/products/energ/data-sources/kode-os-data-source) using **Assign Meters** on each data source page. See [Building data sources](/products/energ/buildings/data-sources). ## Next steps > [card] [Building meters](/products/energ/buildings/meters#add-new-billing-data) > > Upload bills and fill gaps with **+ Add Meter Data**. > [card] [Data quality overview](/products/energ/data-quality/data-quality-overview) > > Return to the data quality hub for alerts and meter comparisons. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Triage billing issues with priorities, statuses, and resolution actions. > [card] [Building Energy — Data Quality](/products/energ/analytics/building-dashboards-energy#data-quality) > > Review meter coverage for every commodity on one building. # Data quality Source: https://docs.kodelabs.com/products/energ/data-quality/data-quality-overview How EnerG monitors and ensures the accuracy and completeness of utility data Use `Data Quality` in EnerG to find and fix meters where bills or interval reads are incomplete, inconsistent, or misaligned. Start here, then open the completeness, alert, or comparison workflow you need. For how EnerG scores coverage and why low scores drop a building from benchmarking, see the data completeness (A score from 0% to 100% that measures billed coverage from each meter's service start through today.) concept in [Data completeness](/products/energ/concepts/data-completeness). ## Choose a task * **Fix completeness gaps**: Review meter timelines and upload missing bills in [Data completeness](/products/energ/data-quality/data-completeness). * **Triage alerts**: Resolve missing bills, gaps, and cycle-length issues in [Alert center](/products/energ/data-quality/alert-center). * **Validate bills against interval reads**: Build comparison sets in [Meter comparisons](/products/energ/data-quality/meter-comparisons). > [!NOTE] > > Unmapped meters do not receive a building completeness score until you assign them to a building. ## Next steps > [card] [Data completeness](/products/energ/data-quality/data-completeness) > > Learn how EnerG calculates meter and building scores and where scores appear in the product. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Open `Alert Center`, filter alerts, resolve issues, and tune portfolio thresholds. > [card] [Meter comparisons](/products/energ/data-quality/meter-comparisons) > > Compare utility bill data to interval meter data and set deviation thresholds. # Meter comparisons Source: https://docs.kodelabs.com/products/energ/data-quality/meter-comparisons Create meter comparison sets to validate utility bills against interval meter readings in EnerG Meter comparisons align utility bill data with interval meter readings so you can validate billed usage in EnerG. Use this workflow when you suspect billing errors or when interval hardware may be out of calibration. Results appear on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) **Comparison** report when a set is configured. Resolve low data completeness (A score from 0% to 100% that measures billed coverage from each meter's service start through today.) on utility meters before you trust a comparison. See [Fix completeness gaps](/products/energ/data-quality/data-completeness#investigate-and-fix-gaps). ## When to use comparisons You run comparisons to check whether a provider is over- or under-billing relative to interval data. You also use them to decide whether an interval meter needs calibration or replacement when deviation stays high across periods. ## Prerequisites You need **both** utility bill data and interval meter data for the **same** service category at the building. | Requirement | Where to confirm | | - | - | | Utility bills ingested | **Completeness** on [Building meters](/products/energ/buildings/meters) or **Data Quality** on meter detail | | Interval points active | **Interval Data** tab on the interval meter; [KODE OS data source](/products/energ/data-sources/kode-os-data-source) | | Meters assigned to the building | [Building data sources](/products/energ/buildings/data-sources) and **Assign Meters** workflows | > [!NOTE] > > Select the interval **point type** that matches how you measure consumption, such as **Differential Electric Energy Accumulator** or **Total Energy**. ## Open meter comparisons from Building meters **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Meters** Click **Meters** in the left sidebar. Review **Completeness** in the table before you compare. Meters at **0%** need [Data completeness](/products/energ/data-quality/data-completeness#investigate-and-fix-gaps) fixes first. ![KODE 1420 Office Meters page with Search Meters Select Data Sources Filter Compare Meters and Unassign Meters buttons and table showing Meter Level Service Type Completeness percentages Data Source Utility Hub Kode OS and provider names](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-meter-comparisons-meters-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=965a284fb2b39eab210d7ed7c72c3cda) Building Meters list with Completeness column and Compare Meters button **3. Click Compare Meters** Click **Compare Meters** in the top-right corner. EnerG opens **Meter Comparison Sets** for the building. ## Meter Comparison Sets list The list shows every comparison configuration you created for the site. ![Meter Comparison Sets page for KODE 1420 Office with Search field Create Comparison button and table with Name Service Type Threshold Base Meters Compare Meters and edit delete actions for Utility Meter to Shadow Meter and Comparison rows](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-meter-comparisons-sets-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=d8bdbebe95cd876d1cd83e8b52aebbc2) Meter Comparison Sets page with search and actions | Column | What it shows | | - | - | | **Name** | Label for the comparison set | | **Service Type** | Category such as **Energy** | | **Threshold** | Allowed percent deviation before the comparison flags a gap, such as **5%** or **2%** | | **Base Meters** | Count of utility or billing meters in the set | | **Compare Meters** | Count of interval or sub-meter feeds to validate | | **Actions** | Edit or delete the set | Use **Search** to filter by name. Click **+ Create Comparison** to add a new set. ## Create a meter comparison set **1. Start Create Comparison** On **Meter Comparison Sets**, click **+ Create Comparison**. The **Create Meter Comparison Set** panel opens. ![Create Meter Comparison Set modal with subtitle validation analysis to compare utility bills against sub-meter data Service Category Electric Natural Gas Lighting Steam Name Meter Comparison Threshold 2 Utility Meters checklist with 8365020 03 selected and Interval Meters with point type dropdowns](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-meter-comparisons-create-set.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=8b4d699a3537b5f7b6c2613da6a5a819) Create Meter Comparison Set panel **2. Set service category and name** Choose **Service Category** tags for every commodity in the analysis, such as **Electric**, **Natural Gas**, **Lighting**, and **Steam**. Enter a **Name** that describes the pair, such as **Utility Meter to Shadow Meter**. **3. Set threshold** Enter **Threshold** as the percent deviation limit. Charts and alerts highlight periods when billed use diverges from interval data beyond this value. > [!TIP] > > Start with a strict threshold, such as **2%**, then relax only after you trust both data streams. **4. Select utility meters** Under **Utility Meters**, check each billing meter to use as the base. Site meters such as **8365020 03** typically carry utility bill data. **5. Select interval meters and points** Under **Interval Meters**, check each interval feed and choose the **point type** dropdown for that meter. Match the point to the quantity you compare against bills. > [!TIP] > > Click **Save**. The new set appears in the list and feeds the building **Comparison** report when configured. ## Thresholds and visualization The **Threshold** marks when deviation is too large for your operational standard. Charts highlight periods that breach the threshold so you focus field checks and vendor questions on those ranges. > [!WARNING] > > A threshold that is too loose hides real drift. A threshold that is too tight creates noise when minor timing differences exist between bill periods and interval reads. When deviation persists, open [Alert center](/products/energ/data-quality/alert-center) for billing issues or [Add new billing data](/products/energ/buildings/meters#add-new-billing-data) when the utility stream is incomplete. ## Next steps > [card] [Building meters](/products/energ/buildings/meters#compare-meters) > > Return to the meters list and **Compare Meters**. > [card] [Data completeness](/products/energ/data-quality/data-completeness) > > Fix billing gaps before you compare streams. > [card] [Data quality overview](/products/energ/data-quality/data-quality-overview) > > Hub for completeness, comparisons, and alerts. > [card] [Building Energy — Comparison](/products/energ/analytics/building-dashboards-energy) > > Review comparison charts on the Energy dashboard. # Arcadia Source: https://docs.kodelabs.com/products/energ/data-sources/arcadia Connect Arcadia utility data at the portfolio level and manage bills, credentials, meters, accounts, and statements for buildings in EnerG Arcadia (Arcadia signs in to utility provider portals and retrieves bills, accounts, and meters on a schedule.) connects EnerG to utility providers so statements, accounts, and meters sync without manual exports. Add the integration once at the [portfolio level](/products/energ/analytics/portfolio-data-sources), then open **Arcadia** from [Building data sources](/products/energ/buildings/data-sources) to assign meters and accounts to each site. ## Add the Arcadia data source (portfolio) You add Arcadia once per portfolio before you manage credentials or map meters at the building level. **1. Open Data Sources** In the portfolio left sidebar, click **Data Sources**. The page shows integrated data source cards and an **All Data Sources** list. ![EnerG Data Sources page showing Utility Hub with Arcadia badge Manual Entry Virtual Entry Kode OS and CSV Upload source cards with left panel listing sources and Add Data Source button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-arcadia-nav.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1054bae1977417a9aa3d7be139a201ef) Data Sources page at the portfolio level **2. Add the source** Click **+ Add Data Source**. Select **ARCADIA** in the **API** dropdown. Enter **Credentials**, **Client Id**, and **Client Secret** from your Arcadia account, then click **Confirm**. ![Add Data Source dialog showing ARCADIA selected with Credentials Client Id and Client Secret fields](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-arcadia-select.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=4c6af12f1a1d524db6416a985b249a94) Add Data Source dialog with ARCADIA selected > [!TIP] > > The Arcadia source appears as a **Utility Hub** card with an Arcadia badge after creation. ## Open Arcadia from the building view After portfolio setup, manage Arcadia for one building from the building **Data Sources** menu. **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Arcadia** Expand **Data Sources** in the left sidebar. Under **All Data Sources**, click **Arcadia** (or **Utility Hub** when labeled that way). The **Arcadia** detail page shows five tabs: **Bills**, **Credentials**, **Meters**, **Accounts**, and **Statements**. Use them to upload bills, connect provider logins, and link discovered meters and accounts to the building. > [!WARNING] > > Validate username and password on the utility provider portal before you enter them in EnerG. Invalid credentials delay collection until you fix them. ## Bills tab Upload PDF utility bills when you need data that is not yet available from automated collection. ![Arcadia Bills tab with Search Bills field Add Bills button and table showing Uploaded date File name preview icon Provider Status Queued and Buildings Unassigned](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-bills.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=5a2f8cf0421e9d564309910bf5ab6c35) Arcadia Bills tab with uploaded bill queue | Column | What it shows | | - | - | | **Uploaded** | Date the file was added | | **File** | PDF filename with preview icon | | **Provider** | Utility provider after OCR or processing | | **Status** | Processing state, such as **Queued** | | **Buildings** | Assignment state, such as **Unassigned** until mapped to a site | Click **+ Add Bills** to drag PDFs into the upload area. OCR extraction can take several hours. Assign processed bills to buildings when **Buildings** shows **Unassigned**. ## Credentials tab Add provider login credentials so Arcadia can retrieve statements and discover accounts. ![Arcadia Credentials tab with Search Credentials Add Credentials button and table showing Connection Success status Login And Data Discovery Success and Total Accounts counts](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-credentials.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=4e6dd193646b46ed02ca526f91cd76de) Arcadia Credentials tab with connection status | Column | What it shows | | - | - | | **Username** | Portal login for the provider account | | **Provider** | Utility company name | | **Status** | **Connection Success** or error state | | **Status Details** | Detail message, such as **Login And Data Discovery Success** | | **Total Accounts** | Accounts discovered under the credential | ### Add a credential **1. Click Add Credentials** On the **Credentials** tab, click **+ Add Credentials**. **2. Choose a provider** In **Search Providers**, find and select the utility, such as **City of Crystal Lake, Illinois**. ![Add a new Credential dialog with Search Providers list showing City of Crystal Lake City of Seattle Liberty Utilities and other utilities](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-add-credential-providers.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=0613fddd6524b1b950f2e72156ebb8df) Add a new Credential provider list **3. Enter login details** Confirm the provider portal, then enter **Username** and **Password**. Use **Open Provider Portal** when you need to verify the login page. ![Add a new Credential form for City of Crystal Lake Illinois with Review Provider Details Open Provider Portal Username and Password fields and Submit button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-add-credential-login.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=405cad9ddc0be28666a9124e878d1632) Add a new Credential login form Click **Submit**. Arcadia downloads available statements. Processing can take a few hours to one day depending on the provider. | Status | Meaning | | - | - | | **Connection Success** | Login succeeded and discovery started | | **In Progress** | Arcadia is still processing | | **Failed** | Invalid credentials or blocked access | ## Meters tab Review discovered meters and assign them to the building. ![Arcadia Meters tab with Search Meters Assign Meters button and table with Meter Number Service Type Unit Account Numbers Provider Service Address and Active status](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-meters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=6b9344757d65cd8cee2fbd96e7cbc70a) Arcadia Meters tab with meter list The table lists each discovered meter with its level, service type, unit, account, and provider. For column definitions, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). For service type groups, see [Service types](/products/energ/reference/data-and-meter-fields#service-types). Click **Assign Meters** to link meters to the open building. ![Add existing Meters modal with Search Meters table showing Meter Number Service Type Provider Name Address checkboxes and pagination 1-20 of 220](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-add-meters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=cf9eb921b7b712d8f829acc58aad293d) Add existing Meters dialog Search meters, select checkboxes for meters that belong to the building, then click **Submit**. Meters appear on [Building meters](/products/energ/buildings/meters) after assignment and processing. ## Accounts tab Review utility accounts discovered from credentials. ![Arcadia Accounts tab with Search Accounts Add Accounts button and table with Provider Name Status CONNECTION\_SUCCESS or INACTIVE Last Statement Date and Active Yes](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-accounts.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=35b316b574a65750f110df66921b7587) Arcadia Accounts tab | Column | What it shows | | - | - | | **Account Number** | Utility account identifier | | **Provider Name** | Utility company | | **Status** | **CONNECTION\_SUCCESS** or **INACTIVE** | | **Provider Classification** | Source type, such as **PUBLISHER** | | **Last Statement Date** | Most recent bill date | | **Active** | Whether the account is active | Click **+ Add Accounts** to link accounts to the building. ![Add existing Accounts modal with searchable table of provider names status CONNECTION\_SUCCESS or INACTIVE last statement dates and pagination 1-50 of 3895](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-add-accounts.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=86cb734896f1cd6076ee69906dcc920c) Add existing Accounts dialog Select accounts with **CONNECTION\_SUCCESS** when possible, then click **Submit**. ## Statements tab Browse bills Arcadia retrieved from connected providers. Use this tab to download statements for audits or cost review. ![Arcadia Statements tab with Search Statements and table showing Statement Date with view icon Type BILL Provider Enbridge Gas Due Date and Amount Due columns](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-arcadia-statements.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=33cfbb09b1cf6249d3c106e107daece4) Arcadia Statements tab | Column | What it shows | | - | - | | **Statement Date** | Bill date. Click the date or eye icon to open the document | | **Type** | Document type, such as **BILL** | | **Provider** | Utility company | | **Due Date** | Payment due date | | **Amount Due** | Billed amount | See [Utility cost analysis](/products/energ/finance/cost-analysis) for how finance teams use downloaded statements. ## Next steps > [card] [Building data sources](/products/energ/buildings/data-sources) > > Return to the building data sources overview. > [card] [Building meters](/products/energ/buildings/meters) > > Review meters assigned to the building after mapping. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Manage portfolio-wide connections and other connectors. > [card] [CSV uploads](/products/energ/data-sources/csv-uploads) > > Bulk-load spreadsheet history when you have structured files. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how bills and meters feed EnerG analytics. # CSV uploads Source: https://docs.kodelabs.com/products/energ/data-sources/csv-uploads Create CSV data sources, map columns, upload billing history, and assign meters at the building level in EnerG CSV uploads let you load historical utility data from spreadsheets or exported reports. Add the source at the [portfolio level](/products/energ/analytics/portfolio-data-sources), then open your named CSV source from [Building data sources](/products/energ/buildings/data-sources) to upload files, review history, and assign meters to each site. Use CSV uploads when you lack [Arcadia](/products/energ/data-sources/arcadia) automation or need a one-time backfill before you switch to ongoing collection. > [!NOTE] > > Download the official template for your upload type before you prepare the file. Use the field reference for supported service types, units of measure, currencies, and required columns. After the first successful mapping, new files for the same source map automatically. ## Prepare the file Before you upload: 1. Download the template for the upload type you need. 2. Review the field reference for allowed **Service Type**, unit of measure, currency, and required columns. 3. Map your column names to platform fields in **Field Mapping** before the file is processed. Required fields include **Account Number**, **Meter Number**, **Meter Name**, **Service Type**, **Usage**, **Unit**, **Start Date**, and **End Date**. ## Add a CSV data source (portfolio) **1. Open Data Sources** In the portfolio left sidebar, click **Data Sources**. **2. Start the upload** Click **+ Add Data Source**. In the **Add Data Source** dialog, select **CSV Upload** from the **API** dropdown. Enter a name for the data source in the **Name** field. ![Add Data Source dialog showing CSV Upload selected in the API dropdown, a Name field, and a file upload area labeled Choose a file or drop it here](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-csv-select.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=57b3fefde5bddbadc10e614b6dc05690) Add Data Source dialog with CSV Upload selected **3. Upload your file** Drag your CSV file into the upload area or click to browse. Click **Next** to proceed to column mapping. **4. Map columns** The **Field Mapping** interface shows your source columns on the left and required target fields on the right. Drag each source column to its matching target field. A progress indicator tracks how many required fields you have mapped. Required fields include **Account Number**, **Meter Number**, **Meter Name**, **Service Type**, **Usage**, **Unit**, **Start Date**, and **End Date**. ![Field Mapping screen with Source column list on the left and Target fields including Account Number, Meter Number, Meter Name, and Service Type on the right, with a progress indicator showing 0 of 8 required fields mapped](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-csv-column-mapping.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=137588f81efcd90cc70c1355155cf927) Field Mapping interface with source and target columns **5. Save the data source** Click **Save**. The source appears under **All Data Sources** for every building in the portfolio. > [!TIP] > > Each CSV source is named for the provider or file set, such as **Goyo - Water** or **Goyo - Electric**. ## Open your CSV source from the building view **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open the CSV source** Expand **Data Sources** in the left sidebar. Under **All Data Sources**, click your CSV source name. The source page shows a **CSV Upload** badge, **PRIVATE** visibility, and **Meters** and **Accounts** tabs. Use **Meters** to upload reads and manage building assignments. ## Meters tab The **Meters** tab lists meters created or updated by CSV uploads for this building. ![Goyo Water CSV Upload data source Meters tab with View Upload History and Upload Data buttons Search Meters Assign Meters and table showing Whole Building Cavana Kinshicho water SITE\_METER m3 unit Active status](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-csv-upload-meters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=fa07a4ec646387b12ad6e9b78a96e5c8) CSV Upload Meters tab with upload controls The table shows each meter's level, service type, unit, account, and status. For column definitions, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). | Control | Purpose | | - | - | | **Search Meters** | Filter by meter number or name | | **View Upload History** | Open the upload log for this source | | **+ Upload Data** | Upload a new CSV file | | **Assign Meters** | Link meters from the portfolio library to this building | ## Upload new data Click **+ Upload Data** to open the **Upload New Data** modal. ![Upload New Data modal with Mapping is complete banner file drop zone default mapping section showing cost to Cost cost\_currency to Cost Currency end\_date to End Date and Cancel Submit buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-csv-upload-new-data.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=f63b8b15f69fd59c50385aa83573fc0b) Upload New Data modal with automatic mapping **1. Open Upload Data** On the **Meters** tab, click **+ Upload Data**. **2. Confirm mapping** When the banner reads **Mapping is complete; New Files will be mapped automatically**, review the **default** mapping list. Each row pairs a source field (for example `cost_currency`) with a display label (for example **Cost Currency**). **3. Choose a file** Drag a CSV into the drop zone or click **Choose a file or drop it here**. **4. Submit** Click **Submit**. EnerG starts a job that moves through **validating**, **processing**, then **done** or **failed**. Wait for the job to finish before you treat the upload as complete. Success and error counts appear when processing ends. For the first file on a new source, complete portfolio-level **Field Mapping** before building uploads inherit the **default** profile. ## View upload history Click **View Upload History** to review every file uploaded to this source. ![Upload History page with Details table listing Goyo Water CSV files with green success counts 23 and 146 orange pending 0 and red error 0 and eye icon per row](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-csv-upload-history.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9155b14795a6b610829923863e00a4df) Upload History page with file status counts | Column | What it shows | | - | - | | **File** | Uploaded filename as a link | | **Job status** | Validating, processing, done, or failed | | **Rows** | Row counts by outcome: success (green), pending (orange), and error (red) | Click the eye icon on a row to inspect row-level results. Failed rows include the row number, field, and reason so you can correct the file and re-upload. ## Assign meters to the building Click **Assign Meters** to link CSV meters that exist in the portfolio but are not yet tied to this building. ![Add existing Meters modal with Search Meters empty table pagination 0 of 0 with Cancel and Submit buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-csv-upload-assign-meters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=dd761b079c1959449d8ee590c2f567e8) Add existing Meters dialog for CSV sources Search the list, select meters, then click **Submit**. If the table is empty, upload a CSV at the portfolio level first or confirm meters are not already assigned elsewhere. ## Unlink meters from the building Remove CSV meters from the building assignment without deleting the underlying records in the portfolio. ![Unlink Meters from Building modal with meter table showing meter numbers names providers addresses Natural Gas and Electric service types checkboxes and pagination 1-10 of 12816](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-csv-upload-unlink-meters.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=764e809e6896dfd72a70a229812aa7b2) Unlink Meters from Building dialog Select meters, then click **Unlink**. Historical reads may remain in the portfolio; the building no longer rolls them into dashboards. See [Unassign meters](/products/energ/buildings/meters#unassign-meters-from-the-building) for the building **Meters** page workflow. ## Troubleshoot upload errors If rows fail validation, check the following. * Compare every required column header to the template spelling and order * Remove blank rows that break validation * Split very large files only when product guidance recommends a row limit * Confirm date formats match what EnerG expects (typically MM/DD/YYYY) * Open **Upload History** and review the red error count for the file ## Next steps > [card] [Building data sources](/products/energ/buildings/data-sources) > > Return to the building data sources overview. > [card] [Building meters](/products/energ/buildings/meters) > > Review all meters assigned to the building after CSV import. > [card] [Arcadia](/products/energ/data-sources/arcadia) > > Automate ongoing utility collection after historical CSV loads. > [card] [Manual entry](/products/energ/data-sources/manual-entry) > > Capture meters that never appear in bulk files or automated feeds. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how imported bills feed EnerG analytics. # KODE OS data source Source: https://docs.kodelabs.com/products/energ/data-sources/kode-os-data-source Connect KODE OS interval meters to EnerG for interval trends, M&V, and forecasting at the building level The **KODE OS** data source connects EnerG to interval meters (Interval meters record usage every hour or every 15 minutes for load shapes, forecasting, and M\&V.) you already map in KODE OS. Add the integration at the [portfolio level](/products/energ/analytics/portfolio-data-sources), then open **Kode OS** from [Building data sources](/products/energ/buildings/data-sources) to assign meters to each site. EnerG pulls electric, natural gas, steam, water, and thermal interval points you template in KODE OS. Use this source for [Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends), [M\&V models](/products/energ/energy-modeling/mv-models), and [Forecasting](/products/energ/energy-modeling/forecasting). Raw interval readings are irregular. EnerG normalizes them into 15-minute and daily virtual points with quality labels before analytics use them. See [Interval data normalization](/products/energ/concepts/interval-data-normalization). > [!NOTE] > > Initial sync can take noticeable time while EnerG processes interval payloads after you connect. ## Connect the source (portfolio) **1. Open Data Sources** In the portfolio left sidebar, click **Data Sources**. ![EnerG Data Sources page with Arcadia Manual Entry Kode OS and CSV Upload source cards and Add Data Source button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-portfolio-nav.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=dfdb1287bcc287c026f223762e124458) Data Sources page at the portfolio level **2. Add KODE OS** Click **+ Add Data Source**. Select **KODE\_OS** in the **API** dropdown, then confirm. ![Add Data Source dialog with KODE\_OS selected in API dropdown](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-add-kode-os.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=c2a2528b552d564d1474739e86a2ac11) Add Data Source dialog with KODE\_OS selected > [!TIP] > > The **Kode OS** source appears in **All Data Sources** after creation. ## Open KODE OS from the building view **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Kode OS** Expand **Data Sources** in the left sidebar. Under **All Data Sources**, click **Kode OS**. The **Kode OS** page shows **PRIVATE** visibility and a **Meters** tab. Interval meters synced from KODE OS appear here before they roll up to building dashboards. ## Meters tab The **Meters** tab lists interval meters assigned to the building. ![Kode OS data source Meters tab with Search Meters Assign Meters button and table showing VFD\_MBH Chiller\_kWh SB\_51A electric SITE\_METER meters and Water\_Meter\_1 Basin\_Cleaning\_Flow\_Meter water meters with Active status](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-kode-os-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=4d91f2e5a00cd43b2d3dcf4fcba86d81) Kode OS Meters tab with electric and water interval meters The table shows each meter's level, service type, unit, and status. For column definitions, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). | Control | Purpose | | - | - | | **Search Meters** | Filter by meter number or name | | **Assign Meters** | Link additional KODE OS meters from the portfolio library | Meters with **both** utility billing and interval feeds also appear on [Building meters](/products/energ/buildings/meters) with an interval badge. ## Assign meters to the building Click **Assign Meters** to link KODE OS meters that exist in the portfolio but are not yet tied to this building. ![Add existing Meters modal with Search Meters and empty table pagination 0 of 0 with Cancel and Submit](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-kode-os-assign-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=0f2c19449a8f146d191a24d57057301c) Add existing Meters dialog for KODE OS Search the list, select meters, then click **Submit**. If the table is empty, confirm meters are modeled in KODE OS and synced to EnerG at the portfolio level first. ## Unlink meters from the building Remove interval meters from the building assignment without deleting the underlying KODE OS point. ![Unlink Meters from Building modal with meter table showing meter numbers names providers addresses service types Natural Gas and Electric checkboxes and pagination 1-10 of 12816](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-kode-os-unlink-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=fcba75c0d3990db5893f67e2b790eae0) Unlink Meters from Building dialog Select meters, then click **Unlink**. Historical interval data may remain in the portfolio; the building no longer includes those meters in rollups. See [Unassign meters](/products/energ/buildings/meters#unassign-meters-from-the-building) for utility-backed meters. ## Use interval data in EnerG After meters are **Active**, interval reads power: | Workflow | Where to open it | | - | - | | **Interval trends** | [Building Energy dashboard — Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends) | | **Meter detail** | [Building meters](/products/energ/buildings/meters) **Interval Data** tab | | **M\&V and forecast** | [Energy Modeling](/products/energ/concepts/energy-modeling) when the meter category is **Interval** | > [!NOTE] > > Pair KODE OS interval meters with [Arcadia](/products/energ/data-sources/arcadia) utility meters on the same building when you run [Meter comparisons](/products/energ/data-quality/meter-comparisons). ## Supported meter families EnerG imports electric, natural gas, steam, water, and thermal interval points from KODE OS. Electric points often cover switchgear, VFDs, chillers, and subpanels, while gas, steam, and water points cover plant and process loads. For how service types group into portfolio totals, see [Service types](/products/energ/reference/data-and-meter-fields#service-types). ## Next steps > [card] [Building data sources](/products/energ/buildings/data-sources) > > Return to the building data sources overview. > [card] [Interval data normalization](/products/energ/concepts/interval-data-normalization) > > See how interval reads become clean 15-minute values. > [card] [Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends) > > Chart sub-daily usage after interval meters are active. > [card] [Building meters](/products/energ/buildings/meters) > > Review interval and utility meters for the building. # Manual entry Source: https://docs.kodelabs.com/products/energ/data-sources/manual-entry Create manual meters and enter utility or waste readings when automated data sources are not available in EnerG Manual entry covers meters that lack [Arcadia](/products/energ/data-sources/arcadia) feeds or [CSV](/products/energ/data-sources/csv-uploads) history. Add the data source at the portfolio level, then open **Manual Entry** from [Building data sources](/products/energ/buildings/data-sources) to create meters and enter readings for one building. ## Add the manual entry data source (portfolio) **1. Open Data Sources** In the portfolio left sidebar, click **Data Sources**. **2. Create the source** Click **+ Add Data Source**. Select **Manual Entry** from the **API** dropdown, complete the required fields, then save. > [!TIP] > > The **Manual Entry** source appears in **All Data Sources** after creation. ## Open Manual Entry from the building view **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Manual Entry** Expand **Data Sources** in the left sidebar. Under **All Data Sources**, click **Manual Entry**. The **Manual Entry** page shows **PRIVATE** visibility and a **Meters** tab. Use it for waste streams, pilot meters, or any commodity you enter by hand. ## Meters tab The **Meters** tab lists every manual meter linked to the building. ![Manual Entry page for One Financial Plaza with Meters tab Search Meters Create Meter and Assign Meters buttons and table showing Plastic and Cardboard waste meters with Service Type Disposed Plastics and Composted Cardboard lbm unit and Active status](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-manual-entry-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=aa91035aa2688cd47563f90f2416efb8) Manual Entry Meters tab with meter list The table shows each meter's level, service type, unit, and status. For column definitions, see [Meter table columns](/products/energ/reference/data-and-meter-fields#meter-columns). | Control | Purpose | | - | - | | **Search Meters** | Filter the table by meter number or name | | **+ Create Meter** | Open the **Create Meter** panel for a new manual meter | | **Assign Meters** | Link existing manual meters from the portfolio library | ## Create a manual meter Click **+ Create Meter** to open the **Create Meter** panel. ![Create Meter side panel with Meter Number Meter Name Service Type Currency Date Became Active Date Became Inactive Scope dropdowns and Cancel Submit buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-manual-entry-create-meter.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=ecbd5eac507a82b80c5b246289f8bec5) Create Meter panel with service type and scope fields **1. Open Create Meter** Click **+ Create Meter** on the **Meters** tab. **2. Enter core details** Provide **Meter Number**, **Meter Name**, **Service Type**, and **Currency**. **3. Set lifecycle and scope** Set **Date Became Active** and **Date Became Inactive** when needed. Choose **Scope**. **4. Submit** Click **Submit**. The meter appears in the table and on [Building meters](/products/energ/buildings/meters). ## Assign meters to the building Click **Assign Meters** to link manual meters that already exist in the portfolio but are not yet tied to this building. ![Add existing Meters modal with Search Meters empty table and pagination 0 of 0 with Cancel and Submit buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-manual-entry-assign-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=69a52377f72f0cf075ecb3442b1e8a94) Add existing Meters dialog Search the list, select checkboxes for meters to add, then click **Submit**. When no meters appear, create them with **+ Create Meter** first or confirm they exist under another building's assignment. ## Unlink meters from the building Remove manual meters from the building without deleting historical reads from the portfolio. ![Unlink Meters from Building modal with meter table showing DTE Energy meters with Electric Natural Gas and Lighting service types addresses and checkboxes with Cancel and Unlink buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-building-manual-entry-unlink-meters.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=e30ea2dcba6f4da7b7d7b8ba13a34ea8) Unlink Meters from Building dialog Select meters in the table, then click **Unlink**. This workflow matches [Unassign meters](/products/energ/buildings/meters#unassign-meters-from-the-building) on the **Meters** page for utility-backed meters. ## Add meter readings After you create a meter, open it from [Building meters](/products/energ/buildings/meters) to enter billing data. **1. Open the meter** Click the meter number in the **Meters** tab or open it from **Building meters**. **2. Click Add Meter Data** Click **+ Add Meter Data**. The side panel opens with entry fields. ![Add Meter Data side panel with Usage Cost Start Date End Date Deregulation Status Estimated and Upload Files fields](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-data-sources-manual-reading-entry.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=8e3eabe844b34497c5b80b36a59b31c6) Add Meter Data side panel **3. Enter values and submit** Provide **Usage**, **Cost**, **Start Date**, and **End Date**. Toggle **Estimated** when the read is not from a final bill. Upload a supporting file when available, then click **Submit**. See [Building meters](/products/energ/buildings/meters#add-new-billing-data) for bulk import, edit workflows, and data table tabs. ## Bulk import via Excel For large volumes of readings, download the Excel template from the meter detail view, fill rows, and import the file. Resolve validation errors before you finalize the import. ## Next steps > [card] [Building data sources](/products/energ/buildings/data-sources) > > Return to the building data sources overview. > [card] [Building meters](/products/energ/buildings/meters) > > Review all meters assigned to the building, including manual meters. > [card] [Arcadia](/products/energ/data-sources/arcadia) > > Replace manual workflows with automated utility statements when accounts are available. > [card] [CSV uploads](/products/energ/data-sources/csv-uploads) > > Load spreadsheet history that is not tied to a specific manual meter. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how manual reads feed EnerG analytics. # ENERGY STAR Portfolio Manager Source: https://docs.kodelabs.com/products/energ/data-sources/portfolio-manager Connect ENERGY STAR Portfolio Manager to EnerG for property links, pull sync, usage push, and certification scores Connect **ENERGY STAR Portfolio Manager** to EnerG so portfolio teams keep compliance data in Portfolio Manager and operational meter data in EnerG. Use one Portfolio Manager data source to link buildings, pull properties and meters, push vetted monthly usage, and sync certification scores. > [!NOTE] > > You need valid Portfolio Manager API credentials with read access for pull jobs. Write permission is required for meter provisioning, usage push, and score write-back. ## What syncs | Direction | Data | Outcome | | - | - | - | | **Portfolio Manager → EnerG** | Properties, meters, consumption, metrics, ENERGY STAR / certification scores | EnerG stays aligned with Portfolio Manager after pull jobs | | **EnerG → Portfolio Manager** | Meter create or map, monthly usage totals, certification scores when enabled | Portfolio Manager receives vetted EnerG data after quality gates pass | | **Connection and status** | Building ↔ Portfolio Manager property link, job history, last sync, errors, manual retry | You can see what synced, what failed, and why | LEED and other non–Portfolio Manager programs stay on [manual certification records](/products/energ/sustainability/certifications). EnerG does not replace Portfolio Manager as the ENERGY STAR system of record. ## Sync rules | Data | Authority | Pull | Push | | - | - | - | - | | Building ↔ property link | You establish the link | N/A | N/A | | Meter definitions | You create in Portfolio Manager or map an existing meter | Import discovers Portfolio Manager meters | You provision from an EnerG meter | | Monthly usage (closed month) | EnerG after **100%** meter completeness | Refresh when a pull job runs | Push the monthly total to the mapped Portfolio Manager meter | | Monthly usage (already pushed) | EnerG for corrections | Pull does not silently overwrite a user-pushed month | Re-push only when you start a correction | | ENERGY STAR score | Portfolio Manager on pull; user-approved on push | Import score into Certifications | Write the score when score push is enabled | | Building area / space use | EnerG Configurations | Portfolio Manager area may inform validation warnings | Area push is not included | Push eligibility uses **strict 100% completeness** for each meter calendar month. Partial months are skipped and recorded in the job detail. ## Connect Portfolio Manager **1. Open Data Sources** In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), click `Data Sources` in the left sidebar. **2. Add Portfolio Manager** Select **+ Add Data Source**, choose **Portfolio Manager**, and enter a name for the connection. **3. Enter credentials** Provide Portfolio Manager API credentials with the permissions your sync plan requires. Validate the connection before you save. **4. Save** Save the data source. It appears under portfolio data sources with the other connectors. ## Link buildings to Portfolio Manager properties Each EnerG building must link to one Portfolio Manager property before push jobs can run. **1. Open the building or sync settings** From the Portfolio Manager data source or the building sync status view, open the property link controls. **2. Select the Portfolio Manager property** Choose the matching Portfolio Manager property for the EnerG building. **3. Confirm the link** Save the link. Pull jobs scope to that property. Push actions stay disabled until the link exists. ## Pull from Portfolio Manager Run or schedule pull jobs to import properties, meters, consumption, and metrics into EnerG. Mapping jobs follow the same patterns as other EnerG data sources. After a successful pull, open building **sync status** to review: * Last pull time * Overall status (success, partial, or failed) * Actionable errors when a job does not complete ## Push meters and monthly usage Configure push after buildings are linked. Push has two steps: meters exist in Portfolio Manager, then monthly totals post to those meters. **1. Provision or map meters** Create Portfolio Manager meters from EnerG meters, or map to meters that already exist in Portfolio Manager. **2. Review eligibility** Before you push, preview which meter-months meet the **100% completeness** gate. Months below 100% are not sent. **3. Push on schedule or Push now** Use the scheduled push when months become eligible, or select **Push now** when a month reaches 100% completeness and you need Portfolio Manager updated before the next run. **4. Correct pushed months deliberately** To update a month that already pushed, start an explicit correction. The scheduler does not overwrite already-pushed months on its own. Job details list per-meter and per-month outcomes, including skip reasons such as incomplete data. ## Certification scores When a building is linked and score sync is available: * Pull ENERGY STAR and related Portfolio Manager certification fields into [Certifications](/products/energ/sustainability/certifications) * Enter or edit scores in EnerG when you track them manually * Enable score write-back when you want user-approved scores written to Portfolio Manager (API-permitted fields only) Certification rows show **score source** (Manual or Portfolio Manager sync) and **last synced** when sync metadata is present. Export certification lists from portfolio or building Certifications when you need an offline file. ## Monitor jobs and sync health Use job history on the Portfolio Manager integration to review timestamps, status, and per-entity outcomes. Retry failed jobs after you fix credentials, mapping, completeness, or Portfolio Manager API errors. Common failure causes: | Symptom | What to check | | - | - | | Push disabled | Building is not linked to a Portfolio Manager property | | Month skipped | Meter completeness below 100% for that calendar month | | API rejection | Credentials, write permissions, meter type, or unit rejected by Portfolio Manager | | Rate limit | Wait for retry with delay; re-run when the job returns to a ready state | ## Next steps > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > See all portfolio ingestion methods next to Portfolio Manager. > [card] [CSV uploads](/products/energ/data-sources/csv-uploads) > > Load historical bills when you are not using Portfolio Manager pull. > [card] [Data completeness](/products/energ/data-quality/data-completeness) > > Confirm meter-month completeness before usage push. > [card] [Building certifications](/products/energ/sustainability/certifications) > > Enter and review ENERGY STAR and other certification scores. # Forecasting Source: https://docs.kodelabs.com/products/energ/energy-modeling/forecasting Configure and train energy usage forecasts for short-term consumption projections in EnerG Train a forecast configuration to project near-term energy usage for a building from interval meter data. In the [building view](/products/energ/get-started/navigation#energy-modeling-submenu), expand **Energy Modeling** in the left sidebar and open **Forecast**. Results also appear on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#forecast) when you select **Forecast** under **Energy Modeling**. For how forecasting extends trained models, see [Energy modeling and M\&V](/products/energ/concepts/energy-modeling#forecasting). > [!NOTE] > > Forecasts rely on interval reads with enough history for the model to learn daily and weekly patterns. Confirm meter completeness on the [Meters](/products/energ/buildings/meters) page before you train. ## Open Forecast **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Energy Modeling** In the left sidebar, expand **Energy Modeling**, then click **Forecast**. ## Manage configurations The **Forecast** page lists every forecast configuration for the building. The page subtitle describes the default horizon: forecast energy usage trends over the coming week. Click **+ Create Configuration** to start the three-step wizard. Use the **Actions** menu on a row to edit or delete an existing configuration. ![Forecast page for Headquarters showing configurations table with Name Forecast Default tag Aggregation Hourly Meters count 1 Status Succeeded Actions menu and Create Configuration button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-forecast-configurations-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=dcc4023b680ba3dc2eb75a6b101bbee6) Forecast configurations list with aggregation and status | Column | What it shows | | - | - | | **Name** | Configuration label. The **Default** tag marks the configuration EnerG uses on forecast dashboards | | **Aggregation** | Rollup level, such as **Hourly** | | **Meters** | Count of meters included | | **Status** | Training state, such as **Succeeded** | | **Actions** | Row menu for edit, delete, or related tasks | ## Create a forecast configuration Click **+ Create Configuration** to open the wizard. Progress appears in the left sidebar across three steps: **Basic Setup**, **Data Selection**, and **Summary**. ### Step 1: Basic setup Define the configuration name and whether it is the default forecast for the building. ![Forecast wizard step 1 of 3 Basic Setup with Name Forecast Default checkbox checked optional Description field and Next button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-forecast-basic-setup.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=64984c578f437620247b04b1955108fe) Forecast wizard step 1 Basic Setup | Field | Purpose | | - | - | | **Name** | Label shown in lists and dashboard filters | | **Default** | When checked, EnerG selects this configuration on forecast views | | **Description** | Optional notes for your team | Click **Next** to continue. ### Step 2: Data selection Choose aggregation, training start date, interval meters, and accuracy thresholds. ![Forecast wizard step 2 Data Selection with Aggregation Hourly Start Date 2025/04/15 meter 10086156 08 Electric Site Meter with point selected badge Threshold Percentage Model Metrics selected and Next button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-forecast-data-selection.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1dd40c441ae03f2652b9efbf00f6a737) Forecast wizard step 2 Data Selection with meter and point selection | Field | Purpose | | - | - | | **Aggregation** | Granularity for the model, such as **Hourly** | | **Start Date** | Optional date to limit training data. Leave empty to use all available history | | **Meter list** | Search and filter by **Meter Scope** and **Service Type**, then select meters | | **Point selected** | For interval meters, pick the point type EnerG uses for the forecast, such as an electric accumulator | | **Threshold Percentage** | **Model Metrics** uses Mean Absolute Percentage Error (MAPE) as the threshold, or **Set the Threshold** for a custom percent | > [!NOTE] > > Many teams use **Hourly** aggregation when they need a week-ahead operational view. Match the point type to the same signal you use in [meter comparisons](/products/energ/data-quality/meter-comparisons). ### Step 3: Summary Review trained model metrics before you finish. ![Forecast wizard step 3 Summary showing Electric Model Successful with Meters Included 1 Meters Selected 1 CVRMSE 13 percent MAPE 11 percent R Squared 0.96 Last Trained 05/16/2026 and Previous Delete Finish buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-forecast-summary.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=fcd929a0ad9e15e70f8e7cfd13e556c5) Forecast wizard step 3 Summary with model accuracy metrics The summary confirms how many meters trained (**Meters Included** versus **Meters Selected**) and the **Last Trained** date. It also reports **CVRMSE**, **MAPE**, and **R Squared** fit. For metric definitions and thresholds, see [Model accuracy thresholds](/products/energ/reference/calculations-and-parameters#model-accuracy). Click **Finish** to save the configuration. Projected consumption appears on forecast charts after processing completes. ## Read forecast results Open **Forecast** from the Building Energy dashboard secondary menu to compare projected consumption to actual use for recent and upcoming periods. Charts update after the scheduled sync cycle, similar to [M\&V analysis](/products/energ/energy-modeling/mv-analysis) results. ## When to use forecasting | Use case | Approach | | - | - | | Near-term operations | Train an **Hourly** configuration to see usage trends over the coming week | | Peak load planning | Compare projected peaks to actual interval data after major equipment changes | | Budget checks | Align forecast horizons with monthly budget periods on [Building budget overview](/products/energ/finance/budget-overview) | | Savings validation | Pair forecasts with [M\&V](/products/energ/energy-modeling/mv-models) when you need both adjusted baselines and forward projections | ## When training fails Forecast runs can fail when interval history is sparse or correlation is weak. Verify the meter has continuous reads, widen the training window, or change the selected point before you retry. > [!TIP] > > If MAPE or CVRMSE exceed your threshold, try a different point type or confirm the meter is not duplicated in [metrics](/products/energ/buildings/meters#include-or-exclude-from-metrics). ## Next steps > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#forecast) > > Review forecast charts without leaving the Energy dashboard. > [card] [Create an M\&V model](/products/energ/energy-modeling/mv-models) > > Configure baselines and savings models alongside forecasting. > [card] [M\&V analysis](/products/energ/energy-modeling/mv-analysis) > > Interpret savings and accuracy metrics after each model run completes. > [card] [Energy modeling overview](/products/energ/concepts/energy-modeling) > > See how M\&V, forecasting, and IPMVP practices fit together in EnerG. # M&V analysis Source: https://docs.kodelabs.com/products/energ/energy-modeling/mv-analysis Review M&V model results, energy savings, and adjusted baseline performance After a model run completes, review Measurement and Verification (M\&V) (Measurement and Verification confirms that savings from energy projects are real, using agreed methods and data.) results on the dashboard. Processing runs as a scheduled job, so metrics may appear after the hourly cycle updates KODE OS. For the methods behind these results, see [Energy modeling and M\&V](/products/energ/concepts/energy-modeling). ## Savings and charts The dashboard summarizes performance against the adjusted baseline (The adjusted baseline is what a building would have used without the measure, under the same conditions.), as shown below. ![Energy M\&V dashboard for One Financial Plaza showing Total Energy Savings of 779,797.11 kWh, Total Energy Savings Percentage of 3.15 percent, a Metrics table comparing Actual versus Adjusted Baseline for District Steam and Electric with Savings and Percent Savings rows, a 2022 Retrofits filter, and an Energy Consumption and Savings Analysis bar chart with an Operation Date marker](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-results.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=7c6058e11bf532dab91ad59e24c7f130) M\&V results dashboard showing total savings, metrics table, and consumption chart * **Totals**: View total energy savings, percent savings, and breakdown views where the UI provides them. * **Trends**: Compare baseline period history, savings over time, and adjusted baseline versus actual series. * **Interval models**: Drill into hourly savings when your model uses interval data. ## Summary tab Open the summary tab for the meters, points, model type, and variables used in the run. You also see accuracy metrics and an acceptable or not acceptable status. For what R-squared, CV-RMSE, and MAPE mean and their thresholds, see [Model accuracy thresholds](/products/energ/reference/calculations-and-parameters#model-accuracy). ## Failed models Failed runs surface a reason such as low R-squared or insufficient data. Read the error message, then adjust inputs or data coverage and create a new model as needed. ## Multiple models per building You can keep more than one model per building when scopes or metering differ. Name and document each model so stakeholders know which run applies to which measure. ## Next steps > [card] [Energy modeling overview](/products/energ/concepts/energy-modeling) > > Review IPMVP options, meter types, and how forecasting extends modeling. > [card] [Create an M\&V model](/products/energ/energy-modeling/mv-models) > > Configure baselines, variables, and thresholds for a new training run. > [card] [Forecasting](/products/energ/energy-modeling/forecasting) > > Project future consumption after you have an acceptable model. # Create an M&V model Source: https://docs.kodelabs.com/products/energ/energy-modeling/mv-models Configure and train measurement and verification models for energy savings analysis [EnerG measurement and verification overview](https://www.youtube.com/embed/3XHNw7Yzm_M?si=-uU3ot2iyfCQtz3z) Configure and train Measurement and Verification (M\&V) (Measurement and Verification confirms that savings from energy projects are real, using agreed methods and data.) models at the building level to verify energy savings. In the [building view](/products/energ/get-started/navigation#energy-modeling-submenu), expand **Energy Modeling** in the left sidebar and open **M\&V**. A trained model estimates the adjusted baseline (The adjusted baseline is what a building would have used without the measure, under the same conditions.) and feeds savings calculations in KODE OS and the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#mv). For the methods behind M\&V, see [Energy modeling and M\&V](/products/energ/concepts/energy-modeling). > [!NOTE] > > You typically need about 12 months of historical data in the baseline window so weather and seasonal patterns train reliably. ## Open M\&V **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Energy Modeling** In the left sidebar, expand **Energy Modeling**, then click **M\&V**. ## Manage configurations The **M\&V** page lists every configuration for the building. Click **+ Create Configuration** to start the five-step wizard. Use the **Actions** menu on a row to edit or delete an existing configuration. ![M\&V page for One Financial Plaza showing configurations table with Name 2022 Retrofits Default tag Meter Category Utility Aggregation Monthly Meters count Baseline Period 01/01/2022-12/31/2022 Configuration Type Auto Configure or Advanced Status Succeeded and Create Configuration button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-configurations-list.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=679097c22711efe814f55a136d152d3d) M\&V configurations list with baseline period and status | Column | What it shows | | - | - | | **Name** | Configuration label. The **Default** tag marks the configuration EnerG uses when you open M\&V from dashboards | | **Meter Category** | **Utility** for bill-based meters or **Interval** for subhourly reads | | **Aggregation** | Rollup level, such as **Monthly** | | **Meters** | Count of meters included in the configuration | | **Baseline Period** | Training window start and end dates | | **Configuration Type** | **Auto Configure** or **Advanced** | | **Status** | Training state, such as **Succeeded** | | **Actions** | Row menu for edit, delete, or related tasks | ## Create an M\&V configuration Click **+ Create Configuration** to open the wizard. Progress appears in the left sidebar across five steps: **Basic Setup**, **Data Selection**, **Baseline Setup**, **Model Configuration**, and **Summary**. ### Step 1: Basic setup Define the configuration name, optional description, and measure dates that mark when savings counting begins. ![M\&V wizard step 1 of 5 Basic Setup with Name 2022 Retrofits Default checkbox Description Measure Start Period Choose Measure Dates selected Implementation Start Date and Operation Start Date 01/01/2023 and Next button](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-basic-setup.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=b90a92de76e71f25162cd3f99865afa6) M\&V wizard step 1 Basic Setup with measure dates | Field | Purpose | | - | - | | **Name** | Label shown in lists and dashboard filters | | **Default** | When checked, EnerG selects this configuration on M\&V dashboards | | **Description** | Optional notes for auditors or internal teams | | **Measure Start Period** | **Get from existing Measure** pulls dates from Scenario Planner, or **Choose Measure Dates** lets you set them manually | | **Implementation Start Date** | When the retrofit or measure work began | | **Operation Start Date** | When the measure reached normal operation. Charts show this as the **Operation Date** marker | Click **Next** to continue. ### Step 2: Data selection Choose meter category, aggregation, and the meters that feed the model. ![M\&V wizard step 2 Data Selection with Meter Category Utility Aggregation Monthly search bar Meter Scope and Service Type filters and selected meters MTR-100214-E01 Electric and MTR-100214-S01 District Steam](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-data-selection.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=bb9da56d548f040c5d5490782a5a894a) M\&V wizard step 2 Data Selection with meter checklist | Field | Purpose | | - | - | | **Meter Category** | **Utility** for monthly billing meters or **Interval** for high-frequency reads | | **Aggregation** | Granularity for interval data, such as **Monthly**, **Daily**, or **Hourly** | | **Meter list** | Search and filter by **Meter Scope** and **Service Type**, then select one or more meters | EnerG trains a separate model per service type when you include multiple commodities, such as **Electric** and **District Steam**. ### Step 3: Baseline setup Select the historical period used to train the baseline and set degree-day base temperatures. ![M\&V wizard step 3 Baseline Setup showing Historical Usage Trends line chart for District Steam and Electric from January through November 2022 Baseline Period January 2022 to December 2022 and Cooling and Heating Base Temperature 65 degrees F](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-baseline-setup.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=d398260db77563462c572d86cae4224a) M\&V wizard step 3 Baseline Setup with usage trends chart | Field | Purpose | | - | - | | **Historical Usage Trends** | Preview monthly use by service type before you lock the baseline window | | **Baseline Period** | **Start Date** and **End Date** for training, such as **01/01/2022 – 12/31/2022** | | **Building Base Temperature** | **Get from Building Information** or **Choose Base Temperature** for custom **Cooling** and **Heating** base values | Confirm the chart shows a full seasonal cycle before you click **Next**. ### Step 4: Model configuration Pick how EnerG trains the regression models and whether to project the baseline forward. #### Auto-configure **Auto-Configure** trains and selects the optimal model for each service type without manual variable selection. ![M\&V wizard step 4 Model Configuration with Auto-Configure selected Disable Projection toggle on and Baseline Projection horizon slider set to 3 months from 1 to 12](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-model-config-auto.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=1062c58920d013a766e386dfa861ab76) M\&V wizard step 4 Model Configuration with Auto-Configure and projection horizon | Field | Purpose | | - | - | | **Configuration Type** | **Auto-Configure** or **Advanced** | | **Disable Projection** | When on, EnerG skips forward baseline estimates | | **Baseline Projection** | Horizon from one to 12 months for future adjusted-baseline estimates | #### Advanced **Advanced** exposes drivers, model type, and accuracy thresholds. Use the scatter plot to confirm relationships before you submit. ![M\&V wizard step 4 Model Configuration with Advanced selected input variable Temperature scatter plot Variables and Model Type dropdowns and Model Metrics threshold option](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-model-config-advanced.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=4d8bf7cff48ac46d32eef5d3951d703a) M\&V wizard step 4 Model Configuration Advanced mode with scatter plot | Field | Purpose | | - | - | | **Select the Input Variable to Plot** | **Temperature**, **Humidity**, **Pressure**, or **Wind Speed** for the preview chart | | **Scatter Plot** / **Historical** | Toggle between correlation view and time-series view | | **Variables** | Drivers such as degree days, holidays, or interval-of-week for interval meters | | **Model Type** | Regression family, filtered by enabled variables | | **Threshold Percentage** | **Model Metrics** uses MAPE as the threshold, or **Set the Threshold** for a custom percent | ### Step 5: Summary Review selections and trained model status before you finish. ![M\&V wizard step 5 Summary showing Baseline Period 01/01/2022-12/31/2022 Meters 2 of 2 Configuration Type Auto Configure Trained Models Electric Model and District Steam Model both Successful with Previous Delete and Finish buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-modeling-mv-summary.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=74a238425da8a5aea6da749c211de705) M\&V wizard step 5 Summary with trained models | Section | What it shows | | - | - | | **Baseline Period** | Confirmed training window | | **Meters Included vs Selected** | How many meters trained versus how many you selected | | **Configuration Type** | **Auto Configure** or **Advanced** | | **Trained Models** | Per-service-type result, such as **Electric Model** and **District Steam Model**, each with **Successful** or failure detail | Click **Finish** to save the configuration. Results sync to dashboards after the scheduled job runs. See [M\&V analysis](/products/energ/energy-modeling/mv-analysis) to read savings totals, charts, and accuracy metrics. > [!WARNING] > > Interval models usually take longer to process. Auto-configure may test multiple candidates before it returns a result. ## When models fail Models can fail when correlation is too weak or the fit falls below your accuracy threshold. Interval training may also reject configurations that do not meet quality rules. See [Model accuracy thresholds](/products/energ/reference/calculations-and-parameters#model-accuracy) for the metrics EnerG checks. > [!TIP] > > If a run fails, widen the baseline, adjust variables, or verify [meter completeness](/products/energ/buildings/meters) before you retry. ## Next steps > [card] [M\&V analysis](/products/energ/energy-modeling/mv-analysis) > > Interpret savings, charts, and accuracy metrics after the hourly job finishes. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#mv) > > Review M\&V savings and consumption charts without leaving the Energy dashboard. > [card] [Energy modeling overview](/products/energ/concepts/energy-modeling) > > See how IPMVP options, meter types, and forecasting fit together in EnerG. > [card] [Forecasting](/products/energ/energy-modeling/forecasting) > > Configure horizons and read projected consumption alongside actual use. # Building budget overview Source: https://docs.kodelabs.com/products/energ/finance/budget-overview Track predicted, actual, and variance energy budget performance for one building in EnerG **Building Budget Overview** compares planned spend to actual utility cost for one building in the [building view](/products/energ/get-started/navigation#budget-submenu). Expand **Budget** in the left sidebar and open **Overview**. Use this page after you configure monthly values in [Model configuration](/products/energ/finance/budgets). For how predicted, actual, and variance relate, see [Budgets and capital planning](/products/energ/concepts/budgets-and-capital-planning#predicted-actual-and-variance). For portfolio rollups across sites, see [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets). ## Open building budget overview **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Budget** In the left sidebar, expand **Budget**, then click **Overview**. ## Summary metrics Three cards at the top roll up performance for the year you select. ![Building Budget Overview for Headquarters with Predicted 0 Actual 5210 Variance dash Accruals toggle on year 2026 Actual vs Budgeted Cost monthly bar chart and Cumulative Variance YTD chart from January through May 2026](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-overview.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=fde3d2907def08732447252ae8c958c9) Building Budget Overview with KPI cards and cost charts | Card | What it shows | | - | - | | **Predicted** | Estimated year-end spend based on current trends | | **Actual** | Billed cost to date for the selected year. A secondary value can show accrued adjustments | | **Variance** (Variance is the difference between budget and actual, in value and percent.) | Difference between budget and actual performance. Displays a dash when no budget is set | When **Budget** columns are zero, configure monthly amounts in [Model configuration](/products/energ/finance/budgets) so variance and predicted values populate. ## Page controls | Control | Purpose | | - | - | | **View Summary** | Open a condensed summary of budget performance | | **Accruals** | Include estimated cost for months without final bills in charts and totals | | **Service type** | Toggle charts and totals by utility (electric, gas, and other configured types) or view the combined total | | **Year** | Calendar year for KPI cards and charts | | **Overview** | Tab that shows charts and the monthly table on this page | | **Download** | Export budget data for the active filters, including all service types in one file when available | > [!TIP] > > Turn **Accruals** (Accruals estimate usage or cost for months that lack final bills.) on for month-end reporting when some utilities have not posted final bills. Turn it off to compare billed amounts only. ## Charts Two charts sit below the summary cards. Use the **service type** toggle to break down total budget versus actual and see which commodities drive increases or reductions. ### Actual vs. budgeted cost A monthly bar chart compares spend to plan for each month in the selected year. | Series | Meaning | | - | - | | **Actual (excl. accrual)** | Billed cost for the month | | **Accrual** | Estimated cost for delivered but unbilled service | | **Budget** | Planned cost from your configured model | ### Cumulative variance A year-to-date chart stacks the same series cumulatively so you can see how variance builds across the year. | Series | Meaning | | - | - | | **Actual YTD (excl. accrual)** | Running total of billed cost | | **Accrual YTD** | Running total of accrued estimates | | **Budget YTD** | Running total of planned cost | ## Monthly and YTD table Scroll below the charts for a tabular breakdown. Switch between **Monthly** and **YTD** to change how rows aggregate. ![Building budget table with Monthly selected showing Date Budget Actual Accrued Variance and Variance percent columns for Jan through Dec 2026 with Actual values populated through May](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-overview-table.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=ec9e80e7a09888227494a962ce0eb3ca) Building budget monthly table with variance columns | Column | What it shows | | - | - | | **Date** | Calendar month in the selected year | | **Budget** | Planned cost for the month | | **Actual** | Billed cost for the month | | **Accrued** | Estimated cost included when **Accruals** is on | | **Variance** | Difference between budget and actual plus accrued | | **Variance %** | Variance as a percent of budget when budget is greater than zero | ## Accruals On **Overview**, enable **Accruals** to include estimates for unbilled months in **Actual** totals, chart series, and variance. Disable **Accruals** when you need a billed-only view for audits or close processes. For how EnerG builds and trues up accruals, see [Accruals](/products/energ/concepts/budgets-and-capital-planning#accruals) and the [accrual behavior reference](/products/energ/reference/calculations-and-parameters#accruals). > [!NOTE] > > Accrual behavior may vary by deployment. Confirm labels and calculations in your workspace before you publish variance reports. ## Next steps > [card] [Model configuration](/products/energ/finance/budgets) > > Create or edit monthly budget values with Manual Flow or Smart Generation. > [card] [Budget planning](/products/energ/finance/budget-planning) > > Create and manage annual budgets with the six-step wizard. > [card] [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets) > > Compare this building to portfolio budget rollups. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Analyze usage and cost trends alongside budget performance. # Budget planning Source: https://docs.kodelabs.com/products/energ/finance/budget-planning Create and manage building energy budgets with the six-step Budget Planning wizard in EnerG **Budget Planning** lets you create, edit, and activate annual energy budgets for one building in the [building view](/products/energ/get-started/navigation#budget-submenu). Expand **Budget** in the left sidebar and open **Planning**. After you finalize a budget, track performance on [Building budget overview](/products/energ/finance/budget-overview). For portfolio-wide budget tables, use [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets). ## Open Budget Planning **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Planning** In the left sidebar, expand **Budget**, then click **Planning**. ## Manage budgets The **Budget Planning** list shows every budget you created for the building. Click **+ Create New Budget** to start the six-step wizard. Use **Actions** on a row to edit or delete a budget. ![Budget Planning page for One Financial Plaza with Search Status and Year filters and table showing budget names Delete 2026 Budget 2024 Budget 2025 Budget with Draft Active and Completed status badges periods and Total Cost up to 1235273 dollars with edit and delete actions](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=eecfacfcdfadc2e09e39b04b95e8d818) Budget Planning list with status and total cost | Column | What it shows | | - | - | | **Budget Name** | Label for the plan. Click the name to open the wizard | | **Status** | **Draft**, **Active**, or **Completed** | | **Period** | Start and end dates for the budget year | | **Total Cost** | Sum of planned cost across included service types | | **Actions** | Edit or delete the budget | | Control | Purpose | | - | - | | **Search** | Find a budget by name | | **Status** | Filter by **Draft**, **Active**, or **Completed** | | **Year** | Filter budgets by calendar year | > [!NOTE] > > Only one budget should be **Active** for a given period when you use it for variance on [Building budget overview](/products/energ/finance/budget-overview). ## Create a budget Click **+ Create New Budget** to open the wizard. Progress appears in the left sidebar across six steps. ### Step 1: Basic setup Define the budget name, planning method, service types, and period. ![Budget Planning wizard step 1 of 6 Basic Setup with Budget Name 2026 Budget Smart Generation selected Model dropdown Service Types Electric and District Steam and Budget Start January 2026 End December 2026](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-basic-setup.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a3308d28a120fdf3106b2f78fe5d410f) Budget Planning wizard step 1 Basic Setup | Field | Purpose | | - | - | | **Budget Name** | Display name in lists and reports | | **Description** | Optional notes | | **Planning Method** | **Smart Generation** builds projections from history, **Reference Year** copies a baseline period, or **Manual Entry** for direct monthly input | | **Model** | Trained model from [Model configuration](/products/energ/finance/budgets) when you use Smart Generation or Reference Year | | **Service Types** | Commodities in the plan, such as **Electric** and **District Steam** | | **Budget Start Date** / **Budget End Date** | Planning period, typically a full calendar year | Click **Next** to continue. ### Step 2: Predicted values Review monthly consumption EnerG predicts from your planning method and service types. ![Budget Planning wizard step 2 Predicted Values table with Month Electric and District Steam columns showing kWh values for each month of 2026](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-predicted-values.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a9a0331a316619f6449984a465cb75ce) Budget Planning wizard step 2 Predicted Values Confirm seasonal patterns look reasonable before you apply rates. Override values later in **Adjustments** if you expect anomalies. ### Step 3: Rate analysis Configure rate and escalation settings per service type, then review monthly consumption and cost. ![Budget Planning wizard step 3 Rate Analysis with District Steam and Electric configuration sections and Electric tab table showing Month Consumption kWh and Cost dollars for 2026 months](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-rate-analysis.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=266982802b023820f4deeb3c295cbf41) Budget Planning wizard step 3 Rate Analysis with Electric monthly cost | Section | Purpose | | - | - | | **District Steam** / **Electric** | Expand each section to set operational parameters and escalation | | **Electric** / **District Steam** tabs | Switch the monthly table between commodities | | **Consumption** / **Cost** | Predicted usage and spend for each month | ### Step 4: Capital planning Add capital projects so the budget reflects expected savings from conservation measures (A conservation measure is one project with savings, capital cost, and incentives.). For the underlying concepts, see [Measures, curves, and scenarios](/products/energ/concepts/budgets-and-capital-planning#measures-curves-and-scenarios). ![Budget Planning wizard step 4 Capital Planning with empty Capital Plans section Add Project link and Electric tab table showing Consumption, Consumption Savings, Consumption After, Cost, Cost Savings, and Cost After columns for 2026](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-capital-planning.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=5991e0477d1d63e5c75969aeab24a069) Budget Planning wizard step 4 Capital Planning with project list Define measures on **Measure Creation** and bundle them into a scenario (A scenario bundles measures into a funding package with priority and dates.) in **Scenario Planner** under [Capital planning](/products/energ/sustainability/capital-planning#measure-creation) before you add projects here. Review payback and savings on [Scenario Analysis](/products/energ/sustainability/capital-planning#scenario-analysis) or compare bundles on [Scenario Comparison](/products/energ/sustainability/capital-planning#scenario-comparison). Click **+ Add Project** to pull measures from capital planning into this budget. Until you add projects, **Consumption Savings** and **Cost Savings** remain zero and **After** columns match baseline predictions. > [!TIP] > > Treat **Payback (Years)** on measures as a planning signal. Confirm capital cost, incentives, and savings against your funding rules before you activate the budget. When a measure reaches **Operations**, align it with [M\&V models](/products/energ/energy-modeling/mv-models) so verified savings match the reductions you planned in the budget. ### Step 5: Adjustments Add manual budget adjustments and occupant cost recovery settings. ![Budget Planning wizard step 5 Adjustments and Recapture with Manual Budget Adjustments empty state Add Adjustment button and Electric tab table with Consumption Adjustments and Cost Adjustments columns](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-adjustments.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9d67163040fc2abc9984dec6f841c9d6) Budget Planning wizard step 5 Adjustments and Recapture Click **+ Add Adjustment** for one-time changes that Smart Generation does not capture. The monthly table shows **Consumption Adjustments**, **Cost Adjustments**, and **After** totals per month. ### Step 6: Review and finalize Review annual totals, emissions, meters, and a historical comparison chart before you save. ![Budget Planning wizard step 6 Review and Finalize showing Total Annual Cost 1235273 Total Carbon Emissions 718516 kgCO2e Total Energy Consumption 7402867 kWh meters MTR-100214-E01 and MTR-100214-S01 and Budget vs Actual Over the Years bar chart](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-planning-review.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=8ea4ab91141cd4b65a4b581173a97781) Budget Planning wizard step 6 Review and Finalize | Metric | What it shows | | - | - | | **Total Annual Cost** | Sum of planned spend for the period | | **Total Carbon Emissions** | Planned emissions in kgCO₂e | | **Total Energy Consumption** | Planned usage across service types | | **Meters Used** | Meters that feed the budget model | | **Budget vs Actual Over the Years** | Compares the new plan to historical actual cost | Click **Finish** to save the budget. Set status to **Active** when the plan is ready for variance tracking. ## Budget statuses | Status | When to use it | | - | - | | **Draft** | Work in progress. Not used in overview variance until activated | | **Active** | Official plan for the period. Drives **Budget** columns on [Building budget overview](/products/energ/finance/budget-overview) | | **Completed** | Closed plan for a prior year. Keep for audit and year-over-year comparison | ## Next steps > [card] [Building budget overview](/products/energ/finance/budget-overview) > > Compare actual spend to your active budget with charts and tables. > [card] [Model configuration](/products/energ/finance/budgets) > > Configure simpler manual or Smart Generation models outside the full wizard. > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Define measures and projects to include in step 4 of the wizard. > [card] [Utility cost analysis](/products/energ/finance/cost-analysis) > > Download utility statements and review cost dashboards. # Budget model configuration Source: https://docs.kodelabs.com/products/energ/finance/budgets Create and train budget prediction models with the five-step Model Configuration wizard in EnerG **Model Configuration** trains regression models that power budget predictions in EnerG. In the [building view](/products/energ/get-started/navigation#budget-submenu), expand **Budget** in the left sidebar and open **Model Configuration**. Link trained models to budgets in [Budget planning](/products/energ/finance/budget-planning) through the **Model** field in Basic Setup. For how budget models produce predicted values, see [Budgets and capital planning](/products/energ/concepts/budgets-and-capital-planning#budget-models). For portfolio rollups, see [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets). For variance against an active plan, see [Building budget overview](/products/energ/finance/budget-overview). > [!NOTE] > > Models need enough historical usage and weather data in the reference period. Confirm meter completeness on [Building meters](/products/energ/buildings/meters) before you train. ## Open Model Configuration **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Model Configuration** In the left sidebar, expand **Budget**, then click **Model Configuration**. ## Manage configurations The **Model Configuration** page lists prediction models for the building. Click **+ Create Configuration** to start the five-step wizard. Click a **Name** to open the summary drawer, or use **Actions** to edit or delete a row. ![Model Configuration page for One Financial Plaza showing table with Name Test Budget 2026 Budget 2025 Budget 2024 Budget Reference Period and Prediction Period date ranges Meters count 2 and edit delete actions plus Create Configuration button](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-list.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a68b743fbbd326565aabebe7a1f18b22) Model Configuration list with reference and prediction periods | Column | What it shows | | - | - | | **Name** | Model label. Click to review training results | | **Reference Period** | Historical window used to train the model | | **Prediction Period** | Future window the model targets | | **Meters** | Count of meters included | | **Actions** | Edit or delete the configuration | ### Review the summary drawer Click a configuration **Name** to open **Summary** without entering the wizard. ![Summary drawer showing Reference Period January 2025 through December 2025 Prediction Period January 2026 through December 2026 Variables Weather Normalization tag and District Steam Model and Electric Model Succeeded badges with Close Delete and Edit Configuration buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-summary-drawer.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=05ec48b6a7e33789e3dc3a6c0e668a1a) Model Configuration Summary drawer with trained models | Field | What it shows | | - | - | | **Reference Period** | Training baseline dates | | **Prediction Period** | Target forecast dates | | **Variables** | Independent drivers, such as **Weather Normalization** | | **Trained Models** | Per-service-type status, such as **Succeeded** for **Electric Model** and **District Steam Model** | Click **Edit Configuration** to change settings or **Delete** to remove the model. ## Create a model configuration Click **+ Create Configuration** to open the wizard. Progress appears in the left sidebar across five steps: **Basic Setup**, **Historical Usage**, **Historical Weather**, **Variables**, and **Summary**. ### Step 1: Basic setup Define the model name, prediction period, and meters by service type. ![Model Configuration wizard step 1 of 5 Basic Setup with Model Name Budget Period Start January 2026 End December 2026 Electric meter MTR-100214-E01 and District Steam meter MTR-100214-S01 selected in tables](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-basic-setup.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=2b8341ebbc15eee34ea9ed94f448a4a8) Model Configuration wizard step 1 Basic Setup with meter selection | Field | Purpose | | - | - | | **Model Name** | Label in lists and in Budget planning **Model** dropdown | | **Description** | Optional notes | | **Period Start** / **Period End** | Prediction period for the model | | **Service Types** | Select meters per commodity. Tables show **Meter**, **Tariff Name**, **Deregulated**, and **Utility Provider Name** | Click **Next** to continue. ### Step 2: Historical usage Choose a reference year and review usage or cost trends that inform the model. ![Model Configuration wizard step 2 Historical Usage with Reference Year January 2025 through December 2025 Budget Historical Usage Trends chart for Electric and District Steam and Usage Cost toggle](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-historical-usage.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=699b50cf56a94f7bc7754bb883429a55) Model Configuration wizard step 2 Historical Usage chart | Control | Purpose | | - | - | | **Reference Year Info** | Historical window for training, such as **January 2025 – December 2025** | | **Budget Historical Usage Trends** | Line chart by service type across the reference year | | **Usage** / **Cost** | Toggle the chart and table between consumption and spend | Scroll below the chart for a monthly table. ![Historical Usage table with Usage selected showing Month District Steam in MBtu and Electric in kWh for each month of 2025](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-usage-table.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=a9af3656fbcdce31feeb69eb16d4f103) Historical Usage monthly table in Usage view Confirm seasonal patterns before you click **Next**. ### Step 3: Historical weather Review temperature and degree-day patterns for the reference period. #### YOY comparison ![Historical Weather step with YOY Comparison tab showing Budget Historical Weather temperature line chart from January through November 2025 in degrees F](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-weather-yoy.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=129a1983c38bd8bef99887b3004e0c39) Model Configuration wizard step 3 Historical Weather temperature chart **YOY Comparison** plots monthly temperature for the reference year. #### Degree days analysis ![Historical Weather Degree Days Analysis tab showing Budget Heating and Cooling Degree Days bar chart with HDD red bars and CDD blue bars by month 2025](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-weather-degree-days.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=41e27987ece82610f75f3a5ec9b53d68) Historical Weather Heating and Cooling Degree Days chart **Degree Days Analysis** shows **HDD** (heating degree days) and **CDD** (cooling degree days) by month. Use this view when **Weather Normalization** is a model variable. See [Weather normalization](/products/energ/reference/calculations-and-parameters#weather-normalization) for base-temperature and tolerance settings. ### Step 4: Variables Select independent variables for the linear regression model. ![Model Configuration wizard step 4 Variables showing Normalization Baseline, Baseline Period Jan 2026 through Dec 2026 Historical Period 1 Year and independent variables Weather Normalization and Occupancy Percentage with add Building Square Foot option](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-variables.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=560a3492d52efde71368b0e4b4bcc286) Model Configuration wizard step 4 Variables | Section | Purpose | | - | - | | **Normalization Baseline** | **Baseline Period** and **Historical Period** for weather-adjusted models | | **Select Independent Variables** | Add drivers such as **Weather Normalization**, **Occupancy Percentage**, or **Building Square Foot** | | **+ Building Square Foot** | Adds floor area from [Building information](/products/energ/buildings/building-information) when available | Use the pencil icon to edit a variable or the trash icon to remove one. ### Step 5: Summary Submit the configuration to train models for each service type. EnerG trains one model per service type you selected in Basic Setup. ![Model Configuration wizard step 5 Summary with info banner Validation takes time and spinner Model training in progress with message that selected options are being used to train a model](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-training.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=b3deabb8239f6c2c3cda90bc082eefef) Model Configuration Summary with training in progress Training runs in the background. An info banner notes that validation takes time. Refresh the wizard or reopen **Summary** from the configuration list when training completes. ![Model Configuration wizard step 5 Summary showing Trained Models District Steam Model and Electric Model each with Successful badge and Previous Delete Finish buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-budget-model-config-summary-success.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=9e72bde2df3457e060d5672536380404) Model Configuration Summary with successful trained models | Section | What it shows | | - | - | | **Trained Models** | One row per commodity, such as **District Steam Model** and **Electric Model** | | **Successful** | Training completed and passed validation for that service type | Click **Finish** to save the configuration. Use **Delete** only when you want to discard the draft before finishing. Failed models show an error state instead of **Successful**; widen the reference period or adjust **Variables** before you retry. > [!WARNING] > > Do not delete a configuration that an **Active** budget in [Budget planning](/products/energ/finance/budget-planning) still references. ## Use models in Budget planning When you create a budget in [Budget planning](/products/energ/finance/budget-planning), choose **Smart Generation** or **Reference Year** and select the trained **Model** from the dropdown in Basic Setup. EnerG applies predicted values from the configuration you completed here. ## Next steps > [card] [Budget planning](/products/energ/finance/budget-planning) > > Build Draft, Active, or Completed budgets using trained models. > [card] [Building budget overview](/products/energ/finance/budget-overview) > > Compare actual spend to your active budget. > [card] [Building information](/products/energ/buildings/building-information) > > Confirm occupancy, area, and envelope inputs that affect variables. > [card] [Building meters](/products/energ/buildings/meters) > > Verify billing completeness before you set reference periods. # Utility cost analysis Source: https://docs.kodelabs.com/products/energ/finance/cost-analysis Review utility costs, download statements, and analyze spending for one building in EnerG You analyze utility spending at the **building level** in EnerG with cost dashboards, original statements, and quality checks. For budget variance and charts, use [Building budget overview](/products/energ/finance/budget-overview). For portfolio-wide rollups, use [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets). ## Navigate to cost views Click `Dashboards`, then `Energy`, and toggle to **Cost** to see building-specific cost data in charts. To create annual budgets, use [Budget planning](/products/energ/finance/budget-planning) under **Budget** in the building sidebar. ## Use cost dashboards Cost dashboards summarize utility spending by building, service type, and time period. Portfolio views show the whole estate. Building views focus on one site with the same filters you use elsewhere in EnerG. ## Download statements You download original utility statements or invoices that your data sources collect. Navigate to the Arcadia data source (click `Data Sources` in the left sidebar, then click the `Utility Hub` card) and open the `Statements` tab to locate and download individual bills. ![Utility Hub Arcadia data source Statements tab showing a searchable list of bills from DTE Energy with columns for Statement Date, Type showing BILL, Provider, Due Date, and Amount Due ranging from 709 to 1198 dollars, with pagination showing 1 to 50 of 77 records](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-finance-statements-download.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=fc7319ff9dbbc4b8469916a0e37ea729) Arcadia Statements tab listing utility bills with dates, provider, and amounts Use downloads when you audit a bill, share proof with finance, or reconcile EnerG cost lines to source documents. > [!TIP] > > Keep statement retrieval inside EnerG when your integration already stores files; you avoid hunting through separate vendor portals. ## Review data quality issues Cost tracking breaks when bills are missing or usage and cost series disagree. Review data-quality signals beside cost charts to spot sudden spikes, flat lines that should vary, or gaps that hide true spend. > [!NOTE] > > For deeper triage, use the [Data quality overview](/products/energ/data-quality/data-quality-overview) to inspect alerts and completeness scores. ## Toggle usage, cost, and emissions Dashboards let you toggle between `Usage`, `Cost`, and `Emissions` perspectives, as shown below. You pick the measure that matches your audience. ![Building-level Energy Monthly Reports dashboard for KODE 1420 Office showing Usage, Cost, and Emission toggle with Usage selected, a Usage Compared to Previous Year bar chart with current and prior year bars, and a Difference percentage chart showing month-over-month variance percentages](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-analytics-site-monthly-reports.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=386fd6be066930634fac703245d00f49) Site Energy dashboard with Usage, Cost, and Emission toggle at the building level Finance stakeholders often start on cost. Sustainability reviews may lead with emissions while you keep cost one toggle away. ## Read portfolio and building breakdowns At portfolio level, compare buildings and regions across consistent service types and periods. At building level, split cost by meter or account where your configuration allows. Combine breakdowns with benchmarks or targets when those modules are enabled for your workspace. ## Next steps > [card] [Building budget overview](/products/energ/finance/budget-overview) > > Compare actual spend to budget with charts and monthly variance tables. > [card] [Budget planning](/products/energ/finance/budget-planning) > > Create annual budgets with the six-step Planning wizard. > [card] [Model configuration](/products/energ/finance/budgets) > > Configure simpler manual or Smart Generation budget models. > [card] [Reporting](/products/energ/finance/reporting) > > Export configurable reports for historical consumption, cost, and emissions data. > [card] [Data quality overview](/products/energ/data-quality/data-quality-overview) > > See how EnerG monitors completeness, anomalies, and alerts across meters and bills. > [card] [Data sources overview](/products/energ/buildings/data-sources) > > Understand how utility data and documents flow into EnerG from connected sources. # Report Builder Source: https://docs.kodelabs.com/products/energ/finance/reporting Create, schedule, and export custom energy, cost, and emissions reports from EnerG You create and run configurable reports from EnerG for energy, water, waste, cost, and emissions metrics. In the [portfolio view](/products/energ/get-started/navigation#portfolio-view), open `Report Builder` in the left sidebar. You define scope, time ranges, metrics, and export formats, then download files for compliance, ESG, and internal updates. ## Navigate to Reports Click `Report Builder` in the portfolio left sidebar. The **Reports** page lists every saved report in the portfolio with the subtitle *All Reports in the portfolio.* ![Reports page with Search field, Author Report Type Export Format and Schedule filters, date range picker, Create New Report button, and a table with Name Author Email Type Export Formats Schedule Created At Updated At and edit and delete actions](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-reports-list.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=d6e4d00820b8339f4edba953bbd1cb69) Reports page with search, filters, and the reports table Click `+ Create New Report` to open the five-step **Report Builder** wizard. To download or change a saved report, click the **edit** icon on that row. ### Filter and search reports | Control | Purpose | | - | - | | **Search** | Find reports by name | | **Author** | Filter by report owner | | **Report Type** | Filter by configuration type | | **Export Format** | Filter by output format such as XLSX or PDF | | **Schedule** | Filter by scheduled or manual reports | | **Select date range** | Limit the list by created or updated dates | ### Reports table columns | Column | Description | | - | - | | **Name** | Report title | | **Author** | Person who created the report | | **Email** | Author email address | | **Type** | Configuration type such as `Custom Configuration` | | **Export Formats** | Output badges such as `.XLSX` and `.PDF` | | **Schedule** | Whether automated delivery is enabled | | **Created At** | Date the report was created | | **Updated At** | Date of the last change | | **Actions** | **Edit** opens the report to download or update settings; **Delete** removes the saved report | ## Create a report The **Report Builder** wizard has five steps: **Basic Setup**, **Dataset & Scope**, **Time Configuration**, **Export Configuration**, and **Review & Submit**. **1. Basic Setup** Choose how you build the report. Select **Custom Configuration** to configure the report step by step with dataset selection, time ranges, metric breakdowns, and export settings. **Feature Based** (PDF Builder with drag-and-drop blocks) may appear as **Coming Soon** in your workspace. ![Report Builder Basic Setup step with Progress 1 of 5, Custom Configuration selected with blue border, Feature Based marked Coming Soon, and Next button](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-basic-setup.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=8126002979c74cc3d14b7200d7550ec8) Report Builder step 1 Basic Setup with Custom Configuration selected Click `Next`. **2. Dataset and Scope** Select the data type and hierarchy level for the report. | Dataset type | Purpose | | - | - | | **Portfolio** | Include all assets in the portfolio | | **Region** | Limit the report to selected regions | | **Building** | Limit the report to selected buildings | | **Meter** | Limit the report to selected meters | ![Report Builder Dataset and Scope step with Progress 2 of 5, Portfolio radio selected showing All assets included, and Region Building and Meter options below](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-dataset-scope.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=1135e46e3bb9cb74ffbdb3ebe33231a8) Report Builder step 2 Dataset and Scope with Portfolio selected Click `Next`. **3. Time Configuration** Define granularity, date range, and comparison logic. **Comparison type** options include **Year over year**, **Quarter over Quarter**, and **Month over Month**. Set **Time granularity** (for example, **Annual**) and enter **Start Year** and **End Year** for the reporting window. ![Report Builder Time Configuration step with Year over year selected, Annual granularity, Start Year 2020 and End Year 2026, and Previous and Next buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-time-configuration.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=2abf90aa8d09364fa8d1a0f2d0228c73) Report Builder step 3 Time Configuration with Year over year and Annual selected Click `Next`. **4. Export Configuration** Configure the report name, structure, metrics, formats, and optional scheduling. Enter a **Name** for the report. Choose **Breakdown hierarchy**: **By Portfolio**, **By Building**, or **By Region**. Under **Metric Outputs**, check the metrics to include: * **Consumption** * **Cost** * **GHG Emissions** * **Data Completeness** ![Report Builder Export Configuration showing Name field, Breakdown hierarchy with By Building selected, and Metric Outputs with Consumption and Cost checked](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-export-configuration.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=1b4c5cd9a71444b0a0925c24dcd8f10f) Report Builder Export Configuration with breakdown hierarchy and metric outputs Set presentation and delivery options: toggle **Include Accruals**, choose **XLSX** or **PDF**, and turn on **Enable Scheduling** for recurring runs. For what each option does, see [Report export options](/products/energ/reference/reporting-and-alerts#report-export). ![Export Configuration section with Include Accruals toggle on, XLSX selected, PDF unselected, Enable Scheduling toggle off, and Previous and Submit buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-export-formats.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=84829ad3ea3708a92d8327e3eb202846) Export Configuration with XLSX selected and scheduling toggle Click `Submit` to save the configuration and start generation. **5. Review and Submit** On **Review & Submit**, EnerG compiles your datasets, applies time settings, and formats the output. A progress message appears while the report generates. This step typically takes 10 to 30 seconds. ![Report Builder Review and Submit step 5 of 5 with Generating Your Report loading spinner and message about compiling datasets and formatting output](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-review-submit.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=6888aebd7f1fadc155c25878ec8b73ed) Report Builder Review and Submit with report generation in progress When processing completes, the page summarizes your choices in three panels: **Dataset & Scope**, **Time Configuration**, and **Export Configuration**. Confirm scope, date range, comparison type, metrics, breakdown, accruals, and export formats before you download. ![Review and Submit step showing Dataset and Scope Portfolio Entire Portfolio, Time Configuration Annual 2020 to 2026 Year over Year, Export Configuration with Consumption and Cost metrics By Building breakdown Include Accruals Yes XLSX format, and Download XLSX and Done buttons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/energ/energ-report-builder-review-complete.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=7e36c959289c674c731fe45a0f0d05e0) Review and Submit summary with Download XLSX and Done buttons Click `Download XLSX` to save the workbook, or click `Done` to return to the **Reports** list. ### Example report workbook Download the [example Report Builder export (XLSX)](/downloads/energ-report-builder-example.xlsx) to review layout, summary tabs, and chart data before you run a report in your workspace. The example export uses **Portfolio** scope, **Annual** granularity, a **2020–2026** date range, **Year over year** comparison, **By Building** breakdown, and **Consumption** and **Cost** metrics with accruals included. For every sheet the workbook contains and what each holds, see [Report Builder workbook sheets](/products/energ/reference/reporting-and-alerts#workbook-sheets). > [!TIP] > > Open **Table of Contents** first in a new export. It lists every sheet and notes which tabs include chart data. ## Download or edit an existing report Saved reports stay on the **Reports** table until you delete them. To run an export again or change settings, open the report from the **edit** icon. **1. Open the report** On the **Reports** page, click the **edit** (pencil) icon on the report row. The **Report Builder** wizard opens on **Review & Submit** with the saved configuration summary. **2. Download the file** Click `Download XLSX` or `Download PDF` (when configured) to export the report with current data. EnerG uses the saved scope, time range, metrics, and formats. **3. Adjust settings optional** To change the report, click `Previous` and move through the wizard steps. You can update any option from report creation: **Basic Setup**, **Dataset & Scope**, **Time Configuration**, or **Export Configuration**. Click `Submit` when you reach **Export Configuration** to regenerate, then download from **Review & Submit**. > [!NOTE] > > You do not download existing reports directly from the table row. Use the **edit** icon to open **Review & Submit** and download from there. ## Delete a report Click the **delete** (trash) icon on a row to remove a saved report you no longer need. > [!WARNING] > > Deleting a report removes its saved configuration. Downloaded files on your computer are not affected. ## Use reports for compliance and ESG Teams use EnerG exports for compliance reporting, ESG submissions, and internal stakeholder updates. You remain responsible for confirming that exported fields meet each program's rules. EnerG supplies the data; your team validates fit for each filing. > [!TIP] > > Store export settings you reuse each quarter so column names and units stay consistent across filing cycles. ## Related exports Detailed meter exports and comparison workflows also live under **Data Quality** in EnerG. Open [Data quality overview](/products/energ/data-quality/data-quality-overview) when you need raw interval or register detail beyond standard summary reports. ## Next steps > [card] [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets) > > Export budget planning data separately from Report Builder when you need monthly plan workbooks. > [card] [Portfolio certifications](/products/energ/analytics/portfolio-certifications) > > Track certification compliance alongside energy and emissions reports. > [card] [Data completeness](/products/energ/data-quality/data-completeness) > > Confirm data coverage before you rely on rolled-up report metrics. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Return to portfolio rankings after you configure recurring exports. # What is EnerG? Source: https://docs.kodelabs.com/products/energ/get-started/introduction Energy management and sustainability reporting for building portfolios in KODE OS [YouTube video player](https://www.youtube.com/embed/SFjZlVp_ioo?si=7dD98p-uQfF5PkDa) EnerG is the KODE Labs energy and sustainability module. You centralize utility data, benchmark buildings, and connect sustainability targets, capital planning, and finance reporting in one place. ## Core capabilities You use EnerG to collect and govern utility data, then analyze and report on performance across your portfolio. * **Utility data automation**: Connections such as Arcadia (Arcadia connects to utility provider accounts and retrieves billing and usage data for connected sites.) pull bill and usage data; you supplement with other configured data sources. * **Performance benchmarking**: You compare buildings using EUI (Energy Use Intensity (EUI) is annual energy divided by floor area, typically expressed per square foot or square meter.), WUI (Water Use Intensity (WUI) is water consumption normalized by floor area or another relevant denominator.), and carbon emissions alongside peer and historical views. * **Energy modeling and M\&V (Measurement and Verification (M\&V) confirms that savings from energy projects are real, using agreed methods and data.)**: You apply IPMVP (The International Performance Measurement and Verification Protocol (IPMVP) defines standard approaches for quantifying energy savings.) Option B and Option C models, correlate usage with drivers such as weather, and support energy forecasting. * **Capital planning**: You define measures and scenarios, estimate savings, and review ROI before you commit funds. * **Sustainability and compliance**: You track targets, initiatives, and certifications with clear ties to metered outcomes. * **Financial planning**: You align budgets, accruals, and reporting with meter and bill timelines. EnerG organizes work in a **portfolio view** and a **building view**. The portfolio view covers `Home`, portfolio `Dashboards`, shared `Data Sources`, and portfolio-wide targets, budgets, and alerts. The building view covers site dashboards, `Building Information`, meters, `Energy Modeling`, and building-level budgets and certifications. See [Portfolio and building navigation](/products/energ/get-started/navigation) for the full sidebar map. Portfolio articles cover portfolio-only features. Building articles cover features you see after you select a site. EnerG runs alongside other KODE OS modules such as AssetOps so operations data and energy data stay connected. ## Who uses EnerG **Energy managers** own tariffs, baselines, and savings narratives across sites. **Sustainability teams** align emissions, water, waste, and certification milestones with metered progress. **Building operators** reconcile usage anomalies, support metering changes, and feed corrective actions back into workflows. **Finance teams** use consistent periods, accruals, and capital scenarios so forecasts match billed reality. ## Next steps > [card] [Portfolio and building navigation](/products/energ/get-started/navigation) > > See how the portfolio and building sidebars map to EnerG features. > [card] [Key concepts](/products/energ/get-started/key-concepts) > > Learn terms such as baselines, calendarization, and data completeness before you configure data. > [card] [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) > > Understand how automated connections, uploads, and meters feed EnerG. > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Compare EUI, WUI, and GHG across your portfolio from the Home page. > [card] [Energy modeling](/products/energ/concepts/energy-modeling) > > See how M\&V options, drivers, and forecasts fit your savings story. # Key concepts Source: https://docs.kodelabs.com/products/energ/get-started/key-concepts A quick orientation to EnerG terminology, with links to the concept pages that explain each idea in depth This page is your map to EnerG language in KODE OS (KODE OS is the platform that connects building systems, apps, and data across your portfolio.). Each term below links to a concept page that explains the idea in full. You will see these terms across the [portfolio and building views](/products/energ/get-started/navigation). ## The data that powers EnerG EnerG runs on two data streams. Monthly **utility bills** drive portfolio rankings, dashboards, targets, and budgets. High-frequency **interval reads** support granular charts, forecasting, and meter-level modeling. A **data source** is any path that brings that data in, such as Arcadia (Arcadia connects to utility provider accounts and retrieves billing and usage data for connected sites.), CSV uploads, manual entry, or a KODE OS interval feed. A **meter** is the device or account boundary each stream reports against. For the full picture of streams, meters, service types, and how EnerG calendarizes bills, see [Data sources and meters](/products/energ/concepts/data-and-meters). Interval reads from KODE OS are cleaned through [interval data normalization](/products/energ/concepts/interval-data-normalization) before charts and models use them. ## Trusting the numbers Data completeness (Data completeness is a score from 0% to 100% that measures billed coverage from each meter's service start through today.) is the trust signal behind every metric. Gaps and overlaps lower the score, and buildings below your threshold drop out of rankings until coverage recovers. See [Data completeness](/products/energ/concepts/data-completeness) for how the score works and what moves it. ## Comparing buildings fairly Benchmarking normalizes usage by area so buildings of different sizes compare fairly. **Energy Use Intensity** (EUI (Energy Use Intensity (EUI) is annual energy divided by floor area.)), **Water Use Intensity** (WUI (Water Use Intensity (WUI) is water consumption normalized by floor area.)), and carbon intensity are the core metrics. See [Benchmarking and intensity metrics](/products/energ/concepts/benchmarking-and-intensity) for how rankings and percentiles work. ## Measuring change over time A **baseline** is a historical reference window you measure future usage against. **Weather normalization** adjusts that comparison for hot and cold years using degree days, so you can separate real savings from weather swings. See [Baselines and weather normalization](/products/energ/concepts/baselines-and-weather-normalization). ## Verifying and forecasting savings Measurement and verification (M\&V) (Measurement and Verification (M\&V) confirms that savings from energy projects are real, using agreed methods and data.) follows IPMVP (The International Performance Measurement and Verification Protocol (IPMVP) defines standard approaches for quantifying energy savings.) practice to confirm savings are real. Models regress energy against weather and other drivers, then project usage forward. See [Energy modeling and M\&V](/products/energ/concepts/energy-modeling). ## Planning spend and reducing carbon Energy **budgets** track plan against actual spend, and **accruals** estimate usage for months that lack final bills. **Capital planning** models the measures and scenarios that reshape future budgets. See [Budgets and capital planning](/products/energ/concepts/budgets-and-capital-planning) and [Emissions accounting](/products/energ/concepts/emissions-accounting) for the carbon side. ## Explore the concepts > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Utility bills, interval reads, meters, service types, and calendarization. > [card] [Interval normalization](/products/energ/concepts/interval-data-normalization) > > How irregular interval reads become clean 15-minute values. > [card] [Data completeness](/products/energ/concepts/data-completeness) > > How EnerG scores billed coverage and why it gates benchmarking. > [card] [Benchmarking](/products/energ/concepts/benchmarking-and-intensity) > > EUI, WUI, and GHG intensity, plus how rankings and percentiles work. > [card] [Baselines and weather](/products/energ/concepts/baselines-and-weather-normalization) > > Reference windows, degree days, and weather-normalized comparisons. > [card] [Energy modeling](/products/energ/concepts/energy-modeling) > > IPMVP options, adjusted baselines, model fit, and forecasting. > [card] [Budgets and capital](/products/energ/concepts/budgets-and-capital-planning) > > Predicted versus actual, accruals, measures, curves, and scenarios. # Portfolio and building navigation Source: https://docs.kodelabs.com/products/energ/get-started/navigation How EnerG organizes portfolio-level and building-level views in the left sidebar [EnerG benchmarking and navigation overview](https://www.youtube.com/embed/18q6b31fWlg?si=mOAkz8zmJezkU2mf) EnerG uses two navigation layouts in KODE OS. You work at the **portfolio view** when you compare sites across your estate. You switch to the **building view** when you configure or analyze one property. Select a building from `Home`, then click `Go to Building` to enter the building view. Use the building selector in the top bar to return to the portfolio. ## Portfolio view The portfolio view is your default landing experience. The left sidebar lists portfolio-wide areas only. ![EnerG portfolio Home page showing EUI, WUI, and GHG toggles, Search Buildings field, All Sites building cards, map with location pins, and Building Rankings bar chart](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-navigation-portfolio-home.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=9e7559cd036f135aad89d28dd479501f) Portfolio Home view with building list, map, rankings, and EUI, WUI, and GHG metric toggles | Sidebar item | Documentation | | - | - | | `Home` | [Portfolio Home](/products/energ/analytics/benchmarking) | | `Dashboards` | [Energy](/products/energ/analytics/portfolio-dashboards-energy), [Water](/products/energ/analytics/portfolio-dashboards-water), [Waste](/products/energ/analytics/portfolio-dashboards-waste) | | `Data Sources` | [Portfolio data sources](/products/energ/analytics/portfolio-data-sources) and connector pages | | `Meters` | [Portfolio meters](/products/energ/analytics/portfolio-meters) | | `Baseline analysis` | [Overview](/products/energ/analytics/baseline-portfolio-overview), [Configurations](/products/energ/analytics/baseline-portfolio-configurations) | | `Target` | [Portfolio targets](/products/energ/analytics/portfolio-targets) | | `Budget` | [Portfolio budget and planning](/products/energ/analytics/portfolio-budgets) (Overview and Planning) | | `Capital Planning` | [Portfolio capital planning](/products/energ/analytics/portfolio-capital-planning) | | `Emissions` | [Overview](/products/energ/analytics/portfolio-emissions-overview), [Benchmarking](/products/energ/analytics/portfolio-emissions-benchmarking), [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors), [Contracts](/products/energ/analytics/portfolio-emissions-contracts), [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions), [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions) | | `Certifications` | [Portfolio certifications](/products/energ/analytics/portfolio-certifications) | | `Alert Center` | [Alert center](/products/energ/data-quality/alert-center) | | `Report Builder` | [Report Builder](/products/energ/finance/reporting) | > [!NOTE] > > Some labels vary by deployment. If you do not see an item, confirm your role and EnerG entitlements in KODE OS. ## Building view The building view opens after you select a site. The left sidebar lists building-specific areas only. ![Building-level EnerG sidebar with Dashboards expanded showing Energy selected with lightning icon and Waste below, followed by Building Information, Meters, Energy Modeling, Data Sources, Budget, Capital Planning, Emissions, and Certifications](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-navigation-building-sidebar-dashboards.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=77645a31af0241e795dbafa38bb32494) Building sidebar with Dashboards expanded showing Energy and Waste ### Primary sidebar | Sidebar item | Documentation | | - | - | | `Dashboards` | [Dashboards Overview](/products/energ/analytics/site-dashboards), [Energy](/products/energ/analytics/building-dashboards-energy), [Water](/products/energ/analytics/building-dashboards-water), [Waste](/products/energ/analytics/building-dashboards-waste) | | `Building Information` | [Building information](/products/energ/buildings/building-information) | | `Meters` | [Building meters](/products/energ/buildings/meters) | | `Energy Modeling` | [Overview](/products/energ/concepts/energy-modeling), [M\&V](/products/energ/energy-modeling/mv-models), [Forecast](/products/energ/energy-modeling/forecasting) | | `Data Sources` | [Building data sources](/products/energ/buildings/data-sources) and connector pages | | `Budget` | [Model configuration](/products/energ/finance/budgets), [Planning](/products/energ/finance/cost-analysis) | | `Capital Planning` | [Capital planning](/products/energ/sustainability/capital-planning) (Basic Information, Measure Creation, Scenario Planner, Scenario Analysis, Comparison) | | `Emissions` | [Emissions](/products/energ/buildings/emissions-overview). Benchmarking, emission factors, contracts, fleet, and fugitive reporting are in the [portfolio Emissions group](/products/energ/analytics/portfolio-emissions-overview). | | `Certifications` | [Building certifications](/products/energ/sustainability/certifications) | Building baseline windows are configured from **Dashboards** > **Energy** > **Baseline Analysis**. See [Configure building baseline windows](/products/energ/analytics/baseline-portfolio-configurations#configure-building-baseline-windows). ### Dashboards submenu Expand `Dashboards` to switch between commodity dashboards. | Submenu item | Purpose | | - | - | | `Energy` | [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) and report menu | | `Water` | [Building Water dashboard](/products/energ/analytics/building-dashboards-water) | | `Waste` | [Building Waste dashboard](/products/energ/analytics/building-dashboards-waste) (KPIs, charts, streams, and pickup entry) | ### Energy Modeling submenu ![Building sidebar with Energy Modeling expanded, M\&V selected, and Forecast listed below](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-navigation-building-sidebar-energy-modeling.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=43ba22e7c3c337b4630f23d97702d6e4) Building sidebar with Energy Modeling expanded showing M\&V and Forecast | Submenu item | Documentation | | - | - | | `M&V` | [M\&V models](/products/energ/energy-modeling/mv-models) | | `Forecast` | [Forecasting](/products/energ/energy-modeling/forecasting) | ### Budget submenu ![Building sidebar with Budget expanded showing Model Configuration and Planning nested items](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-navigation-building-sidebar-budget.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=0409c7066b98d8aade73d9ad84340a30) Building sidebar with Budget expanded showing Model Configuration and Planning | Submenu item | Documentation | | - | - | | `Model Configuration` | [Budget model configuration](/products/energ/finance/budgets) | | `Planning` | [Cost analysis](/products/energ/finance/cost-analysis) | ### Energy dashboard report menu When you open `Dashboards` > `Energy`, a secondary menu lists report types. ![Building Energy dashboard with Dashboards and Energy selected, secondary menu with Monthly Reports, Usage and Cost toggles, and charts](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-navigation-building-dashboards.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=39f0a25ffeb9d35de9ca408c11dd1dfd) Building Energy dashboard with report menu and Usage and Cost toggles | Report menu item | Purpose | | - | - | | `Monthly Reports` | Month-by-month usage and cost on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) | | `Annual Reports` | Annual summaries by service type | | `Comparison` | Compare two time periods | | `Interval Trends` | [Building Energy dashboard — Interval Trends](/products/energ/analytics/building-dashboards-energy#interval-trends) | | `Energy Modeling` | Quick access to M\&V and Forecast | | `Target` | [Building Energy dashboard — Target](/products/energ/analytics/building-dashboards-energy#target) | | `Data Quality` | Completeness and billing gaps for this building | | `Data Table` | Raw billing data in a sortable table | | `Baseline Analysis` | [Building Energy dashboard — Baseline Analysis](/products/energ/analytics/building-dashboards-energy#baseline-analysis) | Deployments with a top-level **Data Quality** group in the building sidebar also include [Data quality overview](/products/energ/data-quality/data-quality-overview), [Data completeness](/products/energ/data-quality/data-completeness), and [Meter comparisons](/products/energ/data-quality/meter-comparisons). ## How portfolio and building views relate Portfolio settings and data sources shape what each building can use. Building-level work rolls up to portfolio dashboards, rankings, and alerts. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart TD subgraph portfolio["Portfolio view"] H["Home"] PD["Dashboards"] DS["Data Sources"] AC["Alert Center"] end subgraph building["Building view"] BD["Dashboards"] BI["Building Information"] EM["Energy Modeling"] BGT["Budget"] end H -->|"Go to Building"| BD DS --> BI PD --> BD AC --> DQ["Data Quality in Energy menu"] ``` ## Next steps > [card] [Portfolio Home](/products/energ/analytics/benchmarking) > > Start in the portfolio view and select a building. > [card] [Portfolio meters](/products/energ/analytics/portfolio-meters) > > Manage meters across the portfolio. > [card] [Building meters](/products/energ/buildings/meters) > > Review meter detail for one building. > [card] [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy) > > Analyze energy reports for one building. # KODE glossary Source: https://docs.kodelabs.com/products/energ/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Calculations and parameters Source: https://docs.kodelabs.com/products/energ/reference/calculations-and-parameters Reference for EnerG target methods, weather normalization settings, distribution curves, accruals, and model accuracy thresholds Look up the calculation methods and parameters that drive EnerG targets, baselines, budgets, and models. For concepts, see [Baselines and weather normalization](/products/energ/concepts/baselines-and-weather-normalization) and [Budgets and capital planning](/products/energ/concepts/budgets-and-capital-planning). ## Target calculation methods Targets set a reduction goal against a baseline. EnerG offers three reduction paths. | Method | How the goal applies | | - | - | | Annual | A fixed reduction each year | | Compounding | A percent reduction that compounds year over year | | Custom milestones | Specific reduction values at chosen years | Set targets on [Portfolio targets](/products/energ/analytics/portfolio-targets). ## Weather normalization Weather normalization trains regression models that adjust usage for heating and cooling conditions. Configure these settings on [Baseline analysis configurations](/products/energ/analytics/baseline-portfolio-configurations). | Setting | Purpose | | - | - | | Building Base Temperature | Pull heating and cooling bases from building information or set custom values | | Temperature Unit | Celsius or Fahrenheit for base temperatures | | Cooling / Heating Base Temperature | Degree-day reference temperatures, often near 65 °F | | Weather averages | Lookback window for normal weather, such as 10 years | | R-Squared Tolerance | Minimum model fit required to mark training successful | ## Distribution curves Distribution curves spread a measure's annual savings across months. EnerG provides defaults derived from degree-day logic, or you build a custom curve whose monthly factors sum to 1.000. | Curve | When to use it | | - | - | | Cooling (CDD) | Summer-weighted savings tied to cooling degree days | | Heating (HDD) | Winter-weighted savings tied to heating degree days | | Flat (1/12) | Even monthly allocation, such as lighting | Assign curves on [Capital planning](/products/energ/sustainability/capital-planning#distribution-curves). ## Accruals Accruals estimate cost for months without final bills. | Behavior | Detail | | - | - | | Source | Prior-year shapes, calendarized to the current period | | Lifecycle | Placeholder until a provider bill posts, then trued up | | Toggle | On for month-end reporting; off for billed-only audit views | | Row marker | Rows show Data Origin of System Accrual until replaced | ## Model accuracy thresholds M\&V and forecast models report fit with three metrics. A model below your thresholds flags as not acceptable. | Metric | What it measures | Lower is better | | - | - | - | | R-squared | Share of variation explained | No (higher is better) | | CV-RMSE | Scatter around actuals | Yes | | MAPE | Average percent error | Yes | Set the threshold in the model wizard, or let EnerG use MAPE as the default. See [Energy modeling and M\&V](/products/energ/concepts/energy-modeling). ## Baseline qualification | Rule | Requirement | | - | - | | Minimum length | 12 consecutive months of complete billed data per category | | Optional length | 24 months, which averages duplicate calendar months | | Disqualifier | Partial months or missing commodities inside the window | ## Next steps > [card] [Baselines and weather](/products/energ/concepts/baselines-and-weather-normalization) > > Understand the reasoning behind these parameters. > [card] [Create baseline configurations](/products/energ/analytics/baseline-portfolio-configurations) > > Apply weather normalization settings across buildings. > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Assign distribution curves to conservation measures. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Set reduction goals with these calculation methods. # Data and meter fields Source: https://docs.kodelabs.com/products/energ/reference/data-and-meter-fields Reference for EnerG service types, units, meter columns, data table columns, and data quality values Look up the fields, columns, and status values that repeat across EnerG meter and data-table views. For concepts, see [Data sources and meters](/products/energ/concepts/data-and-meters). ## Service types Service types describe what flows through a meter. EnerG groups them into energy, water, and waste for portfolio totals. ### Energy Chilled Water, Coal, Coke, Diesel, District Chilled Water, District Heat, District Hot Water, District Steam, Electric, Electric on Site Solar, Electric on Site Wind, Fuel Oil, Kerosene, Lighting, Natural Gas, Other (Energy), Propane, Steam ### Water Irrigation, Municipally Supplied Potable Water (Indoor, Outdoor, Mixed), Municipally Supplied Reclaimed Water (Indoor, Outdoor, Mixed), Other (Indoor, Outdoor, Mixed), Water ### Waste Common streams include Trash, Mixed Recyclables, Cardboard / Corrugated Containers, Food / Food Scraps, Compostable - Mixed / Other, Electronics, Glass, Paper (Mixed, Books, Copy Paper), Plastics (Mixed, Wrap / Film), Batteries, Grass / Yard Trimmings, Fats / Oils / Grease, Building Materials (Carpet, Steel, Concrete, Wood, Mixed), Lamps / Light Bulbs, Office Supplies, Pallets, Regulated Medical Waste, and Other. Additional service types can be added by request after product review. ## Units | Commodity | Common units | | - | - | | Electric | kWh | | Natural gas | ccf, therms, MBtu | | Steam | MBtu, klb | | Water | L, gallons, ccf | | Intensity | kBtu/ft², kWh/ft², MMBtu/ft² (EUI); L/ft² (WUI) | ## Meter table columns These columns appear on [Building meters](/products/energ/buildings/meters) and [Portfolio meters](/products/energ/analytics/portfolio-meters). | Column | What it shows | | - | - | | Meter | Meter number or name. Links to detail | | Meter Description | Optional label | | Building | Site the meter belongs to (portfolio view) | | Level | Main Meter or Sub Meter | | Service Type | Commodity, such as Electric or Natural Gas | | Unit | Usage unit, such as kWh or ccf | | Currency | Currency for cost fields | | Status | Active or inactive | | Completeness | Percent of expected billing coverage | | Data Source | Origin such as Utility Hub, KODE OS, or Virtual Entry | | Provider Name | Utility provider when available | | Account Number | Provider account number | | Account Status | Connection state, such as Connection Success | ## Data table columns The Data Table appears on portfolio and building energy and water dashboards and on each meter's detail view. It has two tabs over the same data. | Tab | Rows | | - | - | | Billing Period | One row per billing period as the utility reports it | | Calendarized | Usage and cost spread across calendar months | | Column | What it shows | | - | - | | Meter | Meter number | | Meter Description | Optional label | | Building Name | Site name | | Building Type | Property category | | State | State or region | | Service Type | Commodity, such as Electric | | Service Provider | Utility name | | Account Number | Provider account number | | Charges | Billed amount | | Currency | Currency for cost | | Usage | Consumption for the period | | Usage Unit | Unit, such as kWh | | Estimated | Whether the row is projected. A dash means final | | Data Origin | How the row entered EnerG, such as Provider or System Accrual | | Start Date | Period start | | End Date | Period end | ## Meter detail fields ### General information | Field | What it shows | | - | - | | Point of delivery number | Provider delivery point identifier | | Description | Optional meter description | | Service Address | Service location on the bill | | Next Expected Statement | Expected date for the next bill | | Account Number | Provider account number | | Account Status | Connection state | | Account Status Details | Provider status code, such as DATAACCESSIBLE | ### Properties | Field | What it shows | | - | - | | Description | Optional notes | | Tenant | Tenant or occupant label | | Equipment | Equipment or load the meter serves | | End Use | End-use category for reporting | | Scope | Main Meter or Sub Meter | | Unit | Usage unit | | Currency | Currency for cost fields | | Service Type | Commodity | | Include In Metrics | Whether the meter rolls into portfolio KPIs and benchmarks | | Service Start Date | First day the meter contributes to analytics | | Service End Date | Last valid day. Empty while active | | Status | ACTIVE or inactive | | Data Source | Feed origin, such as Utility Hub or KODE OS | | Origin | Additional origin category | | Granularity | Billing or read granularity | | Deregulated | Deregulated supply arrangement toggle | ## Data quality legend The Bills Data Quality timeline colors each billing period by coverage. It appears on meter detail and on dashboard Data Quality reports. | Legend color | Meaning | | - | - | | Complete (green) | Full billing coverage for the period | | Delivery Only (orange) | Delivery charges without full supply data | | Supply Only (pink) | Supply data without matching delivery | | Gap (light blue) | Missing expected bills | | Overlap (yellow) | Overlapping or duplicate bill periods | ## Data origin values | Value | Meaning | | - | - | | Provider | Row came from a utility bill | | System Accrual | Row was gap-filled by an accrual estimate | | Manual | Row was entered by a user | ## Next steps > [card] [Building meters](/products/energ/buildings/meters) > > Review and manage meters for one building. > [card] [Data sources and meters](/products/energ/concepts/data-and-meters) > > Understand how bills and interval reads feed these fields. > [card] [Calculations and parameters](/products/energ/reference/calculations-and-parameters) > > Look up completeness, baseline, and model settings. > [card] [Glossary](/products/energ/glossary) > > Find definitions for EnerG and smart building terms. # Emissions reference Source: https://docs.kodelabs.com/products/energ/reference/emissions-reference Field reference for EnerG GHG scope columns, emission factors, volume contracts, fleet, and fugitive records Look up the field schemas for EnerG emissions records and dashboards. For concepts, see [Emissions accounting](/products/energ/concepts/emissions-accounting). ## Scope breakdown columns The scope breakdown tables appear on the [portfolio](/products/energ/analytics/portfolio-emissions-overview) and [building](/products/energ/buildings/emissions-overview) emissions overviews. | Column group | Columns | | - | - | | Scope 2 | Per-commodity emissions, such as District Steam and Electric (kg CO₂e) | | Additional Services | Service-type emissions such as Water (kg CO₂e) | | RECs | REC Retired | | Totals | Total Location Based, Total Market Based | Annual Consumptions mirrors these groups in usage units. Annual Factors shows the intensity factors used, such as kg CO₂e / kWh. ## Emission factor fields Create factor sets on the [emission factors library](/products/energ/analytics/portfolio-emissions-emission-factors). | Field | Purpose | | - | - | | Name | Factor set label | | Methodology | Calculation methodology | | GHG Scope | Scope the factor applies to | | Service Type | Commodity the factor converts | | Geography / Grid | Region or grid the factor represents | | Status | Draft or active. Only active factors apply to reports | | Documentation | Supporting evidence files | ## Factor resolution order EnerG applies the first match in this order for each reading. | Priority | Source | App label examples | | - | - | - | | 1 | Building-specific override | Override | | 2 | Portfolio default | Custom | | 3 | System library for region and year | Default | For how defaults are chosen and how covered load works, see [Emission factors](/products/energ/concepts/emissions-accounting#emission-factors). ## Default factor sources | Activity | Typical system defaults | | - | - | | Electricity (location-based) | EPA eGRID, national inventories, IEA, UK DEFRA | | Electricity (market-based uncovered) | AIB residual mix (EU) or grid average | | Fuels | EPA Emission Factors Hub, UK DEFRA | | Refrigerants | IPCC GWP tables | | Waste | EPA WARM, national waste inventories | | Water and wastewater | Regional models or DEFRA fallback | | T\&D losses | Regional loss rates × grid factor | ## Volume contract fields Create contracts on [Volume contracts](/products/energ/analytics/portfolio-emissions-contracts). | Field | Purpose | | - | - | | Contract Name | Instrument label | | Market / Country | Market and jurisdiction | | Contract Type | Instrument type, such as REC | | Energy Source | Renewable source | | Total Volume | Volume available to allocate | | Emission Factor | Factor applied to the contract | | Reporting Years | Years the contract covers | | Retirement Status | Allocation and retirement state | | Documentation | Supporting files | ## Fleet fields Fleet emissions track Scope 1 mobile combustion on [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). | Record | Key fields | | - | - | | Vehicle | Name, fuel type, vehicle type, emission factor | | Mileage record | Vehicle, distance, distance unit, reporting period, emission factor, documentation | EnerG calculates CO₂e from distance, fuel, and factor automatically. ## Fugitive fields Fugitive emissions track refrigerant loss on [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). | Section | Key fields | | - | - | | Event information | Building, refrigerant, service date | | Equipment | Equipment charged with the refrigerant | | Quantities | Beginning and ending charge, quantity lost | | Service details | Service type and provider | | Documentation | Supporting files | Quantity lost multiplied by refrigerant GWP produces the CO₂e for the event. ## Next steps > [card] [Emissions accounting](/products/energ/concepts/emissions-accounting) > > Understand scopes, methods, and factors. > [card] [Portfolio emissions overview](/products/energ/analytics/portfolio-emissions-overview) > > Review scope totals and offsets. > [card] [Emission factors library](/products/energ/analytics/portfolio-emissions-emission-factors) > > Manage the factors that drive these calculations. > [card] [Glossary](/products/energ/glossary) > > Find definitions for scopes, RECs, and GWP. # Interval normalization labels Source: https://docs.kodelabs.com/products/energ/reference/interval-normalization-labels Reference for normalized interval virtual points, physical limits, field priority, and data quality labels Look up the fields, limits, and quality labels produced by [interval data normalization](/products/energ/concepts/interval-data-normalization). Use this page when you investigate empty intervals, interpolated values, or configuration flags on KODE OS interval meters. ## Virtual point fields by meter type Each meter type writes consumption and rate to standard field names and units. ### Electric | Virtual point | Field name | Data interval | Unit | | - | - | - | - | | Consumption (15-min) | `virtual_normalized_differential_energy_sensor` | `15_min` | kWh | | Consumption (Daily) | `virtual_normalized_differential_energy_sensor` | `daily` | kWh | | Rate | `virtual_normalized_average_power_sensor` | `15_min` | kW | ### Energy (chilled or hot water) | Virtual point | Field name | Data interval | Unit | | - | - | - | - | | Consumption (15-min) | `virtual_normalized_differential_energy_sensor` | `15_min` | kBtu | | Consumption (Daily) | `virtual_normalized_differential_energy_sensor` | `daily` | kBtu | | Rate | `virtual_normalized_average_power_sensor` | `15_min` | kBtu/h | ### Water | Virtual point | Field name | Data interval | Unit | | - | - | - | - | | Consumption (15-min) | `virtual_normalized_differential_volume_sensor` | `15_min` | gal | | Consumption (Daily) | `virtual_normalized_differential_volume_sensor` | `daily` | gal | | Rate | `virtual_normalized_average_flowrate_sensor` | `15_min` | gal/min | ### Natural gas | Virtual point | Field name | Data interval | Unit | | - | - | - | - | | Consumption (15-min) | `virtual_normalized_differential_volume_sensor` | `15_min` | ft³ | | Consumption (Daily) | `virtual_normalized_differential_volume_sensor` | `daily` | ft³ | | Rate | `virtual_normalized_average_flowrate_sensor` | `15_min` | ft³/h | ### Steam | Virtual point | Field name | Data interval | Unit | | - | - | - | - | | Consumption (15-min) | `virtual_normalized_differential_mass_sensor` | `15_min` | lbm | | Consumption (Daily) | `virtual_normalized_differential_mass_sensor` | `daily` | lbm | | Rate | `virtual_normalized_average_massflowrate_sensor` | `15_min` | lbm/h | Daily consumption for standard meters is the sum of normalized 15-minute values. For Carma meters, daily consumption can use Carma's daily consumption point instead of summing intervals. ## Physical limits per 15-minute interval Values outside these limits are nullified and labeled `CANONICAL_LIMIT_OUTLIER`. | Meter type | Minimum | Maximum (per 15 min) | Unit | | - | - | - | - | | Electric | 0 | 5,000 | kWh | | Water | 0 | 25,000 | gal | | Energy | 0 | 7,500 | kBtu | | Steam | 0 | 50,000 | lbm | ## Field priority When a meter exposes multiple fields, normalization selects one field in this order. | Service | Priority (highest first) | | - | - | | Electric | Total energy accumulator, differential energy accumulator, average power sensor, output power sensor | | Natural gas | Total volume accumulator, differential volume accumulator, total energy accumulator, differential energy accumulator, `flowrate_sensor` | | Water | Total volume accumulator, differential volume accumulator, `flowrate_sensor` | | Steam | Total mass accumulator, differential mass accumulator, `massflowrate_sensor` | | Energy | Total energy accumulator, total cooling or heating accumulator, differentials, then power or flow sensors | The chosen field is recorded as `field_used` on the row. ## Label categories | Category | Scope | Contents | | - | - | - | | `data_quality` | Meter-level | Configuration issues that block reliable normalization | | `validation` | Row-level | Invalid or missing readings | | `interpolation` | Row-level | How a timestamp or gap was filled | | `field_used` | Row-level | Name of the selected source field | An empty labels object `{}` means clean measured data with no flags. ## Configuration labels (`data_quality`) | Label | Meaning | Trust | | - | - | - | | `DUPLICATE_FIELD_POINTS` | Multiple points map to the same meter field | Do not trust. Fix mapping. | | `COOLING_HEATING_CONFLICT` | Meter has both cooling and heating fields | Do not trust. Fix mapping. | | `FIELD_INVALID_UNIT` | Unit symbol is invalid for the field type | Do not trust. Fix units. | | `POINT_VALUE_DISCREPANCY` | Meter fields report totals that differ by more than 50% | Do not trust. Investigate sensors. | ## Validation labels (`validation`) | Label | Meaning | Trust | | - | - | - | | `MISSING_RAW_DATA` | No raw data existed for the interval | No data available | | `NEGATIVE_VALUE` | Reading was negative and removed | Invalid reading removed | | `ACCUMULATOR_ZERO` | Accumulator showed zero | Likely sensor error | | `ACCUMULATOR_RESET` | Accumulator decreased (reset or rollover) | Review before use | | `CANONICAL_LIMIT_OUTLIER` | Value exceeded physical limits | Bad reading removed | | `PLATFORM_OUTLIER` | Spike or dip detected against surrounding medians | Glitch reading removed | ## Interpolation labels (`interpolation`) | Label | Meaning | Trust | | - | - | - | | `TIME_WEIGHTED` | Value interpolated to align to the 15-minute grid | Minor timestamp adjustment | | `LINEAR` | Short gap filled by linear interpolation (up to two hours) | Estimate for a short gap | ## Example rows | Meter | Time | Consumption | Rate | Labels | | - | - | - | - | - | | Main Electric | 08:00 | 125.5 | 502.0 | `{}` | | Main Electric | 08:15 | 128.2 | 512.8 | `{"field_used": "total_energy_accumulator"}` | | Main Electric | 08:30 | — | — | `{"validation": "MISSING_RAW_DATA"}` | | Main Electric | 08:45 | 130.1 | 520.4 | `{"interpolation": "LINEAR", "field_used": "total_energy_accumulator"}` | | Main Electric | 09:00 | — | — | `{"validation": "PLATFORM_OUTLIER"}` | ## Next steps > [card] [Interval data normalization](/products/energ/concepts/interval-data-normalization) > > Understand why and how interval data is cleaned. > [card] [KODE OS data source](/products/energ/data-sources/kode-os-data-source) > > Connect the meters that produce these virtual points. > [card] [Data and meter fields](/products/energ/reference/data-and-meter-fields) > > Look up bill-side meter columns and service types. > [card] [Meter comparisons](/products/energ/data-quality/meter-comparisons) > > Compare utility and interval totals after normalization. # Reporting and alerts reference Source: https://docs.kodelabs.com/products/energ/reference/reporting-and-alerts Reference for EnerG Report Builder workbook sheets, export modes, and Alert Center alert types and thresholds Look up the export structures and alert definitions used across EnerG. For the workflows, see [Report Builder](/products/energ/finance/reporting) and [Alert center](/products/energ/data-quality/alert-center). ## Report Builder workbook sheets A Custom Configuration export produces one workbook with these sheets. | Sheet | Contents | | - | - | | Table of Contents | Scope, date range, time grain, metrics, generation time, and a sheet index | | Energy Usage (kWh) | Panel settings, summary statistics, and building-level usage | | Energy Cost (\$) | Panel settings, summary statistics, and building-level cost | | Water Usage (L) | Water usage breakdown when in scope | | Water Cost (\$) | Water cost breakdown when in scope | | Metadata | Total buildings, meters, regions, and generation timestamp | | `_cd_` sheets | Chart data for each metric tab: period, actual, comparison, and building totals | Each metric sheet includes Panel Settings and a Summary block (total, average, high, low, and data point count). ## Report export options | Option | Purpose | | - | - | | Include Accruals | Add accrued values where billing data is incomplete | | XLSX | Export as an Excel workbook | | PDF | Export as a PDF document | | Enable Scheduling | Run the report on a recurring schedule | ## Meter data export modes The Data Export dialog on meter and dashboard data tables offers three modes. | Mode | Purpose | | - | - | | All Fields | Export every column | | Custom Columns | Choose columns, order, decimal precision, and date format | | Existing Template | Run a saved column layout | ## Alert types The [Alert center](/products/energ/data-quality/alert-center) flags data-quality issues for utility meters. | Alert type | Meaning | | - | - | | Billing Gap | An expected bill is missing | | Overlapping Days | Two bills cover the same days | | Short Billing Period | A bill covers fewer days than expected | | Long Billing Period | A bill covers more days than expected | | Delayed Due Date | A bill posted later than expected | | Missing Utility Bill | No bill arrived for a period | ## Alert thresholds Configure thresholds that decide when EnerG raises each alert. | Threshold | Controls | | - | - | | Billing Gap | Days of gap before an alert | | Overlapping Days | Overlap days before an alert | | Short Billing Period | Minimum expected period length | | Long Billing Period | Maximum expected period length | | Delayed Due Date | Days past due before an alert | | Missing Utility Bill | Days without a bill before an alert | ## Next steps > [card] [Report Builder](/products/energ/finance/reporting) > > Create, schedule, and export configurable reports. > [card] [Alert center](/products/energ/data-quality/alert-center) > > Inspect, resolve, and configure data-quality alerts. > [card] [Data completeness](/products/energ/concepts/data-completeness) > > See how alerts relate to the completeness score. > [card] [Data and meter fields](/products/energ/reference/data-and-meter-fields) > > Look up meter and data-table column definitions. # Capital planning Source: https://docs.kodelabs.com/products/energ/sustainability/capital-planning Set baseline periods, utility rates, and building context for decarbonization planning in EnerG Model energy conservation measures (A conservation measure is one project with savings, capital cost, and incentives.) and projected savings for one building with capital planning. In the [building view](/products/energ/get-started/navigation#building-view), click **Capital Planning** in the left sidebar. Start on **Basic Information** to set project parameters before you create measures or scenarios (A scenario bundles measures into a funding package with priority and dates.). For the underlying concepts, see [Measures, curves, and scenarios](/products/energ/concepts/budgets-and-capital-planning#measures-curves-and-scenarios). For portfolio-wide scenario comparison, see [Portfolio capital planning](/products/energ/analytics/portfolio-capital-planning). ## Capital Planning menu After you open **Capital Planning**, a secondary menu lists the workflow pages. | Page | Purpose | | - | - | | **Basic Information** | Building context, baseline period, usage charts, and utility rate settings | | **Measure Creation** | Define individual conservation measures | | **Scenario Planner** | Bundle measures into scenarios | | **Scenario Analysis** | Review savings and financial metrics per scenario | | **Comparison** | Compare scenarios side by side | Complete [Basic Information](#open-basic-information) before you open **Measure Creation**, **Scenario Planner**, **Scenario Analysis**, or **Comparison**. ## Open Basic Information **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Capital Planning** Click **Capital Planning** in the left sidebar, then select **Basic Information** in the Capital Planning menu. The page subtitle explains the goal: establish the foundation for effective decarbonization by setting up your project parameters. ![Capital Planning Basic Information for KODE 1420 Office showing Building and Target Settings with building area 100000 square feet service types Natural Gas Electric Lighting Go to Building Info link Define Baseline Period dates 05/25/2025 to 05/25/2026 Service Type Natural Gas and Annual Usage 22516.29 kWh Annual Cost 843.62](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-basic-information.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=73d7ab0fc2d233b63fd4626818148bf0) Capital Planning Basic Information with building and baseline settings ## Building and target settings The **Building & Target Settings** card summarizes inputs EnerG pulls from the building record. | Field | What it shows | | - | - | | **Building Name** | Site label | | **Primary Heating** / **Primary Cooling** | Dominant HVAC types when configured | | **Building Area** | Gross floor area used in intensity metrics | | **Service Types** | Active commodities, such as **Natural Gas**, **Electric**, and **Lighting** | Click **Go to Building Info** to update area, systems, or service types on [Building information](/products/energ/buildings/building-information). ## Define baseline period Set the historical window that measures and scenarios use as the reference for savings. | Control | Purpose | | - | - | | **Start Date** / **End Date** | Baseline range, such as **05/25/2025 – 05/25/2026** | | **Edit** | Change dates after the initial setup | | **Service Type** | Commodity for the summary metrics and chart below | | **Annual Usage** | Total usage for the selected service type in the baseline window | | **Annual Cost** | Total cost for the same period | Pick a period with stable operations and reliable [meter](/products/energ/buildings/meters) coverage. A full calendar year is typical so seasonal patterns appear in charts. ## Visualize baseline usage Scroll below the baseline settings for a multi-series chart and configuration table. ![Baseline chart with Show Weather Data toggle on displaying Usage kWh bars Cost orange line and Temperature blue line from May 2025 through March 2026 and Factors and Calculations Configuration table for Natural Gas Electric and Lighting with Utility Rate and Base Temperature 65 degrees F](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-baseline-chart.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=4c9597120233e65840d6df4aa0a6e984) Baseline usage chart with weather overlay and factors table | Control | Purpose | | - | - | | **Show Weather Data** | Overlay temperature on the chart to explain seasonal drivers | | **Usage** (green bars) | Monthly consumption for the selected service type | | **Cost** (orange line) | Monthly spend aligned to usage | | **Temperature** (blue line) | Outdoor temperature when weather overlay is on | Use the chart to confirm heating or cooling peaks match expectations before you assign savings curves on [Measure Creation](#measure-creation). ## Factors and calculations configuration The **Factors & Calculations Configuration** table sets rates and degree-day base temperatures per utility type. See [Weather normalization](/products/energ/reference/calculations-and-parameters#weather-normalization) for degree-day settings. | Column | Purpose | | - | - | | **Utility Type** | Service category, such as **Natural Gas**, **Electric**, or **Lighting** | | **Utility Rate** | Blended cost per unit for simple cost translation | | **Base Temperature** | Reference temperature for heating and cooling degree-day logic, often **65 °F** | | **Actions** | Edit icon to update rate or base temperature | > [!TIP] > > Confirm **Utility Rate** matches the tariff class or blended average you use in audit narratives and [Budget planning](/products/energ/finance/budget-planning) rate analysis. ## Measure Creation Select **Measure Creation** in the Capital Planning menu to add conservation measures and manage distribution curves for the building. ![Measure Creation page showing Measures table with LED Lighting Retrofit with Controls Planning status Lighting Systems 538200 kWh savings 75348 cost 2.93 year payback 285000 capital 64600 incentive and Distribution Curves table with Cooling Flat and Heating monthly factors](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-measure-creation.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3155f483043f17f917b549d70e2f487b) Measure Creation page with Measures table and Distribution Curves ### Add a new measure Click **+ Add new Measure** to open the **Add New Measure** panel. ![Add New Measure side panel with Measure Name Primary Category Curve Status Service Types under Annual Savings Capital Cost Incentive Amount Incentive Source and Close Save buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-add-measure.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=3f748336041baa029c79d75bfd55f501) Add New Measure panel with category, curve, and savings fields | Field | Purpose | | - | - | | **Measure Name** | Project label shown in the measures table | | **Primary Category** | Grouping such as **Lighting Systems** or **HVAC Systems** | | **Curve** | Distribution curve from the table below, such as **Flat** or **Heating** | | **Status** | **Planning**, **Implementation**, or **Operations** | | **Service Types** | Fuels affected by the measure | | **Capital Cost (\$)** | Upfront project cost | | **Incentive Amount (\$)** | Rebates or grants applied to payback | | **Incentive Source** | Program or funder name for audit trails | Click **Save** to add the row. EnerG calculates payback and fuel-specific savings columns after you save. Additional fields may appear when you select multiple service types. ### Create a custom curve Click **+ Add new Curve** to open the **Create Custom Curve** panel when default cooling, heating, or flat curves do not fit your measure. ![Create Custom Curve side panel with banner Monthly values must total 1.000 Curve Name Curve Type twelve monthly fields Total Sum 0.00 Sum less than 1 validation and Close Create Curve buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-create-curve.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=7a0950b3a6845c7e6b54fd16c3804abe) Create Custom Curve panel with monthly factors | Field | Purpose | | - | - | | **Curve Name** | Label in the **Distribution Curves** table | | **Curve Type** | Curve family EnerG uses for allocation logic | | **January – December** | Monthly factor for each month | > [!WARNING] > > Monthly values must total **1.000** for annual distribution. The footer shows **Total Sum** and a validation message until the monthly factors sum to one. Click **Create Curve** when the sum reaches **1.000**. The new curve appears in the **Curve** dropdown on **Add New Measure**. ### Measures table The **Measures** table lists every conservation project for the building. Scroll horizontally to see financial and fuel-specific columns. | Column | What it shows | | - | - | | **Building Name** | Site the measure applies to | | **Measure Name** | Project label, such as **LED Lighting Retrofit with Controls** | | **Measure Type** | Specific technology, such as **Interior and Exterior Lighting** | | **Status** | Lifecycle state, such as **Planning**, **Implementation**, or **Operations** | | **Primary Category** | Grouping, such as **Lighting Systems** or **HVAC Systems** | | **Total Savings** | Annual energy reduction, such as **538,200 kWh** | | **Cost Savings** | Annual cost impact, such as **\$75,348** | | **Electric Saving** | Electric commodity savings when applicable | | **Water Saving** | Water savings when applicable | | **District Steam Saving** | Steam savings when applicable | | **Consumption Savings** | Combined consumption impact across fuels | | **Payback (Years)** | Simple payback from capital cost, incentives, and savings | | **Capital Cost** | Upfront project cost, such as **\$285,000** | | **Incentive Amount** | Rebates or grants, such as **\$64,600** | | **Actions** | Edit or delete the measure | > [!WARNING] > > Set **Operations** status only when the **operation date** is in the past and savings have started. When a measure reaches **Operations**, EnerG can connect it to [M\&V models](/products/energ/energy-modeling/mv-models). Keep the measure record aligned with the meters and models that prove savings. ### Distribution curves The **Distribution Curves** table defines how annual savings spread across months. EnerG provides default cooling, heating, and flat curves derived from degree-day logic on [Basic Information](#define-baseline-period). | Column | What it shows | | - | - | | **Name** | Curve label, such as **Cooling (CDD 65°F)**, **Heating (HDD 65°F)**, or **Flat (1/12)** | | **Curves** | Curve family: **Cooling**, **Heating**, or **Flat** | | **Jan – Dec** | Monthly factor that sums to the annual savings profile | Assign a curve when you create or edit a measure so EnerG allocates savings without manual spreadsheet work. For when to use each curve type, see [Distribution curves](/products/energ/reference/calculations-and-parameters#distribution-curves). ## Scenario Planner Select **Scenario Planner** in the Capital Planning menu to bundle measures into funding packages. Each scenario lists included measures with implementation and operation dates. ![Scenario Planner page showing LED Only High priority scenario with one measure Full retrofit Medium priority with five measures and implementation and operation dates and Edit Scenario buttons](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-capital-planning-scenario-planner.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=d0ed723a6d0fec20eca9e8a38a1cbcc1) Scenario Planner with expandable scenario cards Click **+ Add new Scenario** to create a bundle. Expand a card to review measures or click **Edit Scenario** to change dates and membership. ### Scenario cards Each card shows the scenario name, a **priority** tag, and a table of measures when expanded. | Element | What it shows | | - | - | | **Scenario name** | Bundle label, such as **LED Only** or **Full retrofit** | | **Priority** | **High**, **Medium**, or **Low** planning priority | | **Measure Name** | Measure included in the bundle | | **Measure Status** | Status of each measure, such as **Planning** | | **Implementation Date** | When work begins | | **Operation Date** | When savings start in reporting | | **Edit Scenario** | Opens the scenario for changes | > [!NOTE] > > **Implementation date** marks construction or install start. **Operation date** marks when savings first count in forecasts and analysis. ### Create a scenario Click **+ Add new Scenario** to open the **Create Scenario** panel. ![Create Scenario side panel with Scenario Name Priority dropdown and checklist of energy conservation measures with curve tags such as Flat Cooling and Heating and Close Create Scenario buttons](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-create-scenario.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=f31f780dc367f5990548d95b33606743) Create Scenario panel with measure selection | Field | Purpose | | - | - | | **Scenario Name** | Label on the scenario card | | **Priority** | **High**, **Medium**, or **Low** | | **Select Energy Conservation Measures** | Check each measure to include. Tags show the assigned curve, such as **Flat (1/12)** or **Cooling (CDD 65°F)** | Click **Create Scenario**, then open **Edit Scenario** on the card to set **Implementation Date** and **Operation Date** per measure when projects phase over time. Review savings and payback on [Scenario Analysis](#scenario-analysis). Compare bundles on **Comparison** or at the portfolio on [Portfolio capital planning](/products/energ/analytics/portfolio-capital-planning). ## Scenario Analysis Select **Scenario Analysis** in the Capital Planning menu to review financial and environmental impacts for a scenario you built on [Scenario Planner](#scenario-planner). ![Scenario Analysis page for LED Only scenario with Consumption Cost Emissions toggles showing Projected Annual Reduction 538200 kWh Percent Reduction 12.02 percent Payback 2.93 years Capital Cost 285000 Incentives 64600 and Target chart with TTM Baseline Forecast TTM Target Final and Target Rolling lines to 2040](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-scenario-analysis.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=d9af811434abd12fbf8af5a26c4e1c50) Scenario Analysis with KPI cards and Target chart ### Page controls | Control | Purpose | | - | - | | **Consumption** / **Cost** / **Emissions** | Switch KPI cards and charts between usage, spend, and kgCO₂e | | **Energy** | Filter by energy scope or commodity | | **Scenario** | Select the scenario to analyze, such as **LED Only** | | **Measures** | Multi-select measures within the scenario | ### Summary metrics Five cards roll up results for the active scenario and view. | Card | What it shows | | - | - | | **Projected Annual Reduction** | Total annual savings, such as **538,200 kWh** | | **Percent Reduction** | Savings as a percent of baseline, such as **12.02%** | | **Projected Payback Period** | Simple payback in years, such as **2.93** | | **Total Capital Cost** | Sum of measure capital costs | | **Total Incentives** | Sum of rebates and grants | ### Target chart The **Target** chart compares long-range trajectories through **2040**. | Series | Meaning | | - | - | | **TTM Baseline** | Trailing-twelve-month baseline without measures | | **Forecast TTM** | Projected use after measures take effect | | **Target Final** | Long-term reduction goal, such as a **2040 Reduction Goal** | | **Target Rolling** | Rolling path from baseline toward the final target | Use the goal dropdown, such as **2040 Reduction Goal**, to align the chart with targets you set on [Portfolio targets](/products/energ/analytics/portfolio-targets) and review on the [Building Energy dashboard](/products/energ/analytics/building-dashboards-energy#target). ### Baseline vs. projected and measures timeline Scroll below the Target chart for service-type breakdowns and a measure schedule. ![Scenario Analysis detail with Baseline vs Projected bar chart for District Steam and Electric Reduction table showing 538200 kWh electric reduction and Measures Timeline with LED Lighting Retrofit vertical bar at July 2026](https://mintcdn.com/kodelabs/0XJAojMwxBOWwfw5/images/energ/energ-capital-planning-scenario-analysis-detail.png?fit=max\&auto=format\&n=0XJAojMwxBOWwfw5\&q=85\&s=d36ebbe24b943795340f72d3f98bcf52) Scenario Analysis Baseline vs Projected chart Reduction table and Measures Timeline | Section | What it shows | | - | - | | **Baseline vs. Projected** | Grouped bars by service type comparing baseline to projected use | | **Reduction** | Table with **Baseline**, **% of Baseline**, **Projected**, and **Reduction** per fuel | | **Measures Timeline** | Gantt-style view of when each measure starts savings based on **Operation Date** | **Scenario Analysis** shows trailing-twelve-month **Forecast TTM** and baseline separation for one scenario. Use it when you explain how savings emerge across seasons before you compare bundles on **Comparison**. > [accordion] When you stagger implementation dates > > Set each measure **Implementation Date** when work begins and **Operation Date** when savings start. Staggered dates keep cash flows and contractor access realistic in one scenario. ## Scenario Comparison Select **Comparison** in the Capital Planning menu to evaluate multiple scenarios side by side on one chart and table. ![Scenario Comparison page with LED Only and Simple Upgrade selected Consumption toggle Capital Planning Roadmap chart showing Baseline Target and scenario TTM lines from 2025 to 2040 and table comparing LED Only Simple Upgrade and Full retrofit savings capex incentives and payback](https://mintcdn.com/kodelabs/Ph3_DUgZdP7vM-lt/images/energ/energ-capital-planning-scenario-comparison.png?fit=max\&auto=format\&n=Ph3_DUgZdP7vM-lt\&q=85\&s=7923f2a85a0bfef60b4d1fc0539d6322) Scenario Comparison with Capital Planning Roadmap and comparison table ### Page controls | Control | Purpose | | - | - | | **Energy** | Scope or commodity filter for the roadmap | | **Scenario tags** | Select two or more scenarios, such as **LED Only** and **Simple Upgrade** | | **Target goal** | Long-range target overlay, such as **2040 Reduction Goal** | | **Consumption** / **Cost** / **Emissions** | Switch the roadmap and table between usage, spend, and CO₂e | ### Capital Planning Roadmap The **Capital Planning Roadmap** chart projects each selected scenario from the current year through **2040**. | Series | Meaning | | - | - | | **Baseline** | Reference use without new measures | | **Target** | Published reduction path toward the goal year | | **LED Only TTM** / **Simple Upgrade TTM** / **Full retrofit TTM** | Trailing-twelve-month forecast per scenario (line color matches the scenario) | Steeper drops indicate larger or earlier savings. Compare scenario lines to **Target** to see which bundle closes the gap soonest. ### Comparison table The table below the chart summarizes each scenario for the active toggle. | Column | What it shows | | - | - | | **Scenario Name** | Bundle label | | **Total Annual Savings (Consumption)** | Annual energy reduction | | **Total Annual Savings (Cost)** | Annual cost reduction | | **Total Annual Savings (CO2e)** | Annual emissions reduction | | **Capex** | Total capital cost | | **Incentives** | Total rebates and grants | | **Projected Annual Consumption** | Percent reduction or projected use metric for the scenario | | **Simple Payback (Years)** | Payback period for the bundle | Use the table to compare **Simple Payback** and **Capex** when you shortlist funding options. Open [Scenario Analysis](#scenario-analysis) for a single-scenario drill-down. > [!TIP] > > Compare at least one low-capex scenario and one deep-retrofit scenario so stakeholders see the tradeoff between payback speed and total savings. For portfolio-wide comparison across buildings, use [Portfolio capital planning](/products/energ/analytics/portfolio-capital-planning). ## Next steps > [card] [Portfolio capital planning](/products/energ/analytics/portfolio-capital-planning) > > Compare scenarios across buildings on the roadmap chart. > [card] [Budget planning](/products/energ/finance/budget-planning) > > Add capital projects from planning into an annual budget in step 4. > [card] [Building information](/products/energ/buildings/building-information) > > Update area, heating, cooling, and service types before you lock a baseline. # Building certifications Source: https://docs.kodelabs.com/products/energ/sustainability/certifications Track certifications, awards, fees, expiration dates, and investment analysis for one building in EnerG Manage and track certifications for one building in the [building view](/products/energ/get-started/navigation#building-view). Click **Certifications** in the building left sidebar. The page subtitle reads: manage and track certifications for your building. For portfolio-wide dashboards, see [Portfolio certifications](/products/energ/analytics/portfolio-certifications). ## Open Certifications **1. Select a building** From [Portfolio Home](/products/energ/analytics/benchmarking), open a building in the building view. **2. Open Certifications** Click **Certifications** in the left sidebar. ![Certifications page for One Financial Plaza with Certification Details table showing LEED Silver BOMA Gold and Energy Star Expired with fees and Renewable Status and Total Investment Analysis stacked bar chart for consulting and certification fees](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-certifications.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=f733441c97bd3ad9fa471774ef6c7cb4) Certifications page with detail table and cost analysis chart Click **+ New Certification** in the top right to add a record. ## Certification Details table The **Certification Details** table lists every certification for the building. Use the download control to export the certification list to a spreadsheet. | Column | What it shows | | - | - | | **Certification Name** | Program and level, such as **LEED - Building Design and Construction (BD+C) - Silver** | | **Score** | Program score when you enter one (for example, ENERGY STAR or LEED). Score source can be Manual or Portfolio Manager sync when linked | | **Expiration** | Expiration date for the award | | **Data Last Reviewed** | Last time data was verified | | **Consulting Fee** | Third-party consulting cost, such as **\$120,000** | | **Certification Fee** | Program registration or audit fee, such as **\$25,000** | | **Renewable Status** | Days until renewal or **Expired** badge | | **Responsible** | Owner or contact for the certification | | **Documentations** | Linked evidence files | | **Historical Logs** | **View History** link for prior versions | | **Actions** | Edit icon to open **Edit Certification** | | Status badge | Meaning | | - | - | | Blue pill with day count | Active certification with days remaining, such as **133 days** | | **Expired** (red) | Past expiration date until you renew or update the record | ## Cost analysis **Total Investment Analysis Across Certification Programs** summarizes consulting and certification fees in a stacked bar chart. | Series | Meaning | | - | - | | **Consulting Fee** (green) | Professional services cost per program | | **Certification Fee** (orange) | Direct program or audit fees | Compare programs such as **LEED**, **BOMA**, and **Energy Star** to plan renewal budgets. Portfolio rollups use the same structure on [Portfolio certifications](/products/energ/analytics/portfolio-certifications#cost-analysis). ## Add a certification Click **+ New Certification** to open **Add Existing Certification**. ![Add Existing Certification panel with Switch to Custom Awards button Certification Program Category Rating Award Date Expiration Date fees Upload Documents and Notes with Close and Submit buttons](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-certifications-add.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=40845d3ef9a5cf1e6c78ab352635a3c9) Add Existing Certification panel **1. Open the add panel** Click **+ New Certification**. Toggle **Switch to Custom Awards** when the program is not in the standard list. **2. Select program and rating** Choose **Certification Program**, **Category**, and **Rating** from the cascading dropdowns. **3. Enter dates, fees, and scores** Set **Award Date** and **Expiration Date**. Enter **Certification Fee** and **Consulting Fee** when you track spend. Enter the program **Score** when you track ENERGY STAR, LEED, or other scored programs. When the building is linked to [Portfolio Manager](/products/energ/data-sources/portfolio-manager), pulled scores can populate this field and optional write-back can update Portfolio Manager. **4. Upload evidence and add notes** Add PDF certificates or supporting files in **Upload Documents**. Enter points or compliance references in **Notes**. > [!TIP] > > Verify the uploaded file matches the award name and rating on the certificate. **5. Submit** Click **Submit**. The row appears in **Certification Details** and updates the cost chart. ## Edit a certification Click the edit icon in **Actions** to open **Edit Certification**. ![Edit Certification panel for LEED Building Design and Construction Silver with Award Date 06/14/2013 Expiration 12/31/2099 Certification Fee 25000 Consulting Fee 120000 upload area and notes about 52 LEED v3 points](https://mintcdn.com/kodelabs/2xuyqDwhBYJ11inY/images/energ/energ-building-certifications-edit.png?fit=max\&auto=format\&n=2xuyqDwhBYJ11inY\&q=85\&s=1e8f0f31b6a7933f8a70b4c02f77efeb) Edit Certification panel with LEED Silver example Update any field, replace documents, or revise **Notes**. Click **Update** to save changes. Use **View History** in the table to review prior versions without losing audit context. ## Monitor expiration Watch **Renewable Status** for day counts that approach zero. Past dates show **Expired** until you renew the certification and update dates or upload a new certificate. > [!TIP] > > Log consulting and certification fees separately so portfolio cost analysis and annual budgets stay accurate. ## Next steps > [card] [Portfolio certifications](/products/energ/analytics/portfolio-certifications) > > Review certification coverage and investment charts across the portfolio. > [card] [Building information](/products/energ/buildings/building-information) > > Confirm building attributes that support certification narratives. > [card] [Capital planning](/products/energ/sustainability/capital-planning) > > Connect improvement measures to certification goals. > [card] [Portfolio targets](/products/energ/analytics/portfolio-targets) > > Align reduction targets with certified commitments. # FDD configuration Source: https://docs.kodelabs.com/products/fdd/configuration Set up and manage fault detection rules, device monitoring parameters, notification policies, and multi-config folders for your building equipment. FDD configuration is where you activate and customize monitoring rules (routines) for your building equipment. You define which devices to monitor, what thresholds trigger alerts, and how notifications are delivered. All routines you create on the [Routines](/products/fdd/routines) page automatically become available for configuration here. KODE also provides a set of pre-built library routines that are available by default to every client. Library routines cover common fault conditions across airside, chilled water, and hot water systems. > [!NOTE] > > Navigate to `FDD` from the left sidebar, open the secondary sidebar, and select `Configs`. ## Key capabilities * Configure events for real-time alarms * Apply routines from the KODE Library or custom rules * Set device-specific parameters and thresholds * Manage notification policies and priority levels * Use Multi-Config (Separate folders under one routine so different device groups can use different parameters, priorities, and policies.) folders for granular control * Batch configure multiple routines simultaneously ## The Configs list The Configs list displays all available routines and their current state. Each row provides a summary of the routine's configuration. Use the search bar and filter dropdowns (`Status`, `Priority`, `Policy`, `Source`, `Recommended Type`) to find specific routines. Select `Clear All` to reset filters. ![Batch Configuration page with search bar, filter dropdowns for Status, Priority, Policy, Source, and Recommended Type, and a table listing routines with columns for Name, Event Status, Fault Status, Number of Folders, Number of Devices, Priority, and Source showing Library and Local sources](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-batch-configuration.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=9c48c5f10c54487939fce156b04cd25b) The Batch Configuration page lists all routines available for configuration, including both library and locally created routines Expand a routine row to view its Multi-Config folders with individual device counts, statuses, and priorities. ![Configs list with an expanded routine showing Folder 1 and Folder 2 with device counts and Alert priority levels](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-configs-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=b083f86751256517c188916f9d392799) Expanded routine showing Multi-Config folders with device counts and priorities | Column | Description | | - | - | | `Name` | Routine name. Select to open detailed configuration. | | `Event Status` | Current state: Not Configured, Disabled, Enabled, or Mixed | | `Fault Status` | Indicates whether fault tracking is active | | `Number of Folders` | Count of Multi-Config folders | | `Number of Devices` | Count of devices assigned to the routine | | `Policy` | Assigned notification policy | | `Priority` | Priority level for generated events | | `Source` | Origin of the routine: Local or Library | | `Recommended Type` | Suggested equipment type for the routine | | `Description` | Summary of what the routine monitors | ### Status definitions | Status | Meaning | | - | - | | **Not Configured** | No devices or parameters assigned yet | | **Disabled** | Configured but not actively generating events | | **Enabled** | Actively monitoring devices and generating events | | **Mixed** | Multi-Config folders have different enabled or disabled states | ## Configure routines Choose quick configuration for default settings across many routines, or detailed configuration to tune one routine at a time. > [tab] Quick configuration > > Use quick configuration to apply default settings to multiple routines at once. > > ![Batch Configuration list with one routine selected and bottom toolbar showing Delete, Disable, Enable, and Configure buttons](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-configs-select.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=36944f6b681fd58ecab022229e6ec272) > > Select routines using checkboxes to access bulk actions in the bottom toolbar > > **1. Select routines** > > Select the checkboxes next to one or more routines in the Configs list. > > **2. Choose a notification policy** > > Select the `Configure` button in the toolbar. Choose a notification policy from the dropdown. > > **3. Apply the configuration** > > Select `Configure` to find compatible devices, create the configuration, and apply default parameters without enabling monitoring yet. > > Select `Configure and Enable` when you want the same batch action to start monitoring immediately after configuration. > [tab] Detailed configuration > > Select a routine name in the Configs list to open its Config Details page. Use detailed configuration to fine-tune parameters, select specific devices, and set notification preferences for individual routines. Each folder maintains its own independent configuration -- you can set different parameters, status setup, notification settings, base settings, and possible solutions per folder. > > **1. Open the config details** > > Select the routine name link from the Configs list. The Config Details page has three areas: > > * **Top tabs**: Navigate between `Overview` and individual Multi-Config folders (for example, `VAVs`, `FCUs`) with a `+` button to add folders > * **Main panel**: View and select devices with search and filters > * **Right panel**: Adjust `Routine Params`, `Status Setup`, `Notification Settings`, `External Data Source`, `Base Settings`, and `Possible Solutions` > > ![Config Details page for Temperature Less than Setpoint while Occupied showing Overview and Folder 1 tabs, a device table listing FCU208, VAV\_406, VAV\_204, VAV\_407, VAV\_401, VAV\_209, VAV\_104, VAV\_103, and FCU\_207 with area and point count columns, and Routine Params panel showing parameter values](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-devices.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=d68d447beeae50cf48790d94f16b9b97) > > The Config Details page with device list, routine parameters, and folder tabs > > **2. Select devices to monitor** > > The main panel lists all compatible devices automatically. Select individual device checkboxes, use `Select All`, or search by name. Expand a device row to view its main point and other points. > > For devices with multiple point options, choose the correct combination from the dropdown next to each device. > > **3. Configure parameters** > > The `Routine Params` panel on the right displays adjustable parameters with default values and info tooltips. Adjust values based on your equipment and environment. > > | Parameter | Purpose | > | - | - | > | `Arbitrary Heating Setpoint` | Temperature threshold for heating faults | > | `Alarm On Delay` | Duration a fault condition must persist before generating an event | > | `Arbitrary Cooling Setpoint` | Temperature threshold for cooling faults | > | `Start Delay` | Wait time after system startup before monitoring begins | > | `Heating Setpoint Deadband` | Acceptable deviation from the heating setpoint | > | `Cooling Setpoint Deadband` | Acceptable deviation from the cooling setpoint | > | `Single Setpoint Deadband` | Acceptable deviation when a single setpoint is used | > | `Return to Normal Delay` | Duration a condition must be normal before closing the event | > > > [!TIP] > > > > Use tighter tolerances for critical spaces like server rooms. Apply longer delays for equipment with startup fluctuations. Set wider dead band values for older equipment to reduce false positives. > > **4. Configure status setup** > > The `Status Setup` section controls whether the routine generates events, faults, and actively monitors devices. > > ![Status Setup section showing Event Config toggle enabled with description about real-time monitoring, Fault Config toggle disabled with description about daily non-critical analysis, and Routine Config toggle enabled with description about monitoring devices in this folder](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-status-setup.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=4b2f62ff563ef69f986f2fea685e38fd) > > Status Setup with Event Config, Fault Config, and Routine Config toggles > > * **Event Config**: Events are real time and used to monitor critical assets and send high priority notifications. > * **Fault Config**: Faults are generated daily and used to analyze non-critical comfort, energy, and mechanical issues. > * **Routine Config**: Enable to start monitoring devices in this folder. > > **5. Set notification settings** > > The `Notification Settings` section defines how events from this routine are grouped and delivered. > > ![Notification Settings panel showing Grouping Policy set to None, Priority set to Alert, and Notification Policy set to Alert Notification](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-notification-settings.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=9f15652bd51aa9781384d7a3cd7f959f) > > Notification Settings with grouping policy, priority, and notification policy > > **Grouping Policy** > > * **None**: Sends individual notifications for each event. Use for critical alarms that need individual attention. > * **Reference-based (Groups related events by ontology relationships to form incidents and reduce notification volume.)**: Groups related events by ontology relationships to reduce notification volume and form incidents. > * **Data Source (Groups events by the connected data source. Use for Datasource Down or Device Down routines.)**: Groups events by data source. Use for connectivity routines such as Datasource Down or Device Down. > > **Priority**: Select the priority level for events generated by this routine (Life Safety, Critical, Warning, Alert, or Info). > > **Notification Policy**: Select the policy that defines which contacts receive notifications and through which channels. > > **6. Add external data source** > > The `External Data Source` section lets you connect an external system for work order delivery from this config. Select `+ Add External Source` to configure a connection. This section is optional. > > If you configure an external data source here, it applies only to this configuration and overrides any external data source set on the [notification policy](/products/fdd/notification-policies). > > **7. Configure base settings** > > The `Base Settings` section defines the content included in event notifications. Default values use dynamic tokens that pull from the routine definition. > > ![Base Settings panel showing Event Name with routines.name token, On Create Description and On End Description with routines.description token, On Create Notes and On End Notes fields, and Possible Solutions with Add Solution button](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-base-settings.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=e352605fd4be8905dde5398239da6fda) > > Base Settings with event naming, descriptions, notes, and possible solutions > > * **Event Name**: The name displayed for generated events. Defaults to `{{routines.name}}`. > * **On Create Description**: Text included when an event is created. Defaults to `{{routines.description}}`. > * **On Create Notes**: Additional notes attached to the event at creation. > * **On End Description**: Text included when an event closes. Defaults to `{{routines.description}}`. > * **On End Notes**: Additional notes attached when the event closes. > * **Possible Solutions**: Add possible solutions that appear in event reports to guide troubleshooting. Select `+ Add/Sort Solution` to add entries. > > **8. Save the folder** > > Select `Save Folder` to apply your configuration. Repeat for each folder as needed. > > > [!WARNING] > > > > When you save a folder, the config appears as `Disabled` in the Configs list. You must enable it separately from the list. ## Enable or disable configs After saving your configuration, return to the Configs list to enable event generation. **1. Find the config** Search for the routine name in the Configs list. The newly configured routine displays as `Disabled`. ![Batch Configuration list showing Temperature Less than Setpoint while Occupied with Disabled status, 2 folders, 4 devices, Critical priority, and Library source](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-configs-disabled.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=86671d844ef9980c53005114446027b2) After saving, the config appears as Disabled in the Configs list with its folder and device counts **2. Enable the config** Select the checkbox next to the routine and select `Enable` from the bottom toolbar. ![Batch Configuration list with Temperature Less than Setpoint while Occupied now showing Enabled status after selecting Enable from the toolbar](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-configs-enabled.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=4fe7c81af79ca00257a69dbe473982da) Select the routine and click Enable to start generating events > [!NOTE] > > Disabled configs retain their configuration but stop generating new events. Re-enable a config to resume monitoring without reconfiguring. ## Multi-Config folders Multi-Config (Separate folders under one routine so different device groups can use different parameters, priorities, and policies.) folders let you apply different configurations to the same routine across different groups of devices. ### When to use folders * Different thresholds for server rooms versus standard offices * Separate notification policies for critical versus non-critical equipment * Distinct priority levels based on equipment location or function * Varying operating parameters for different equipment generations ### Create a folder **1. Add the folder** Select `+ Folder` in the top menu of the Config Details page. Enter a descriptive name and select `Create`. **2. Configure devices** Select devices for this folder and configure parameters, status setup, notification settings, base settings, and possible solutions independently from other folders. ### Manage folders Switch between folders using the top tabs. Each folder maintains its own device selection, routine parameters, status setup, notification settings, external data source, base settings, and possible solutions. Save each folder before switching to another. > [!NOTE] > > A routine's status displays as Mixed when its folders have different enabled or disabled states. ## Best practices ### Deployment strategy 1. Start with critical equipment that has the highest operational impact. 2. Use recommended routine types matched to your equipment. 3. Test with a small group of devices before rolling out broadly. 4. Review event output after one week and adjust thresholds as needed. 5. Document any customizations for future reference. ### Parameter tuning | Equipment type | Recommendation | | - | - | | **New equipment** | Start with default parameters and refine after observing initial output | | **Older equipment** | Increase tolerances and deadbands to account for sensor drift | | **Critical spaces** | Minimize delays and tighten tolerances for faster response | ## Troubleshooting > [accordion] No compatible devices found > > Verify that your devices have the correct point templating applied. Routines match devices based on canonical point types defined in the ontology. > [accordion] Configuration does not save > > Check for error messages or red-highlighted fields in the configuration panel. All required fields must be completed before saving. > [accordion] Too many notifications > > Increase tolerances and delay values to filter out transient conditions. Consider using Reference-based grouping to consolidate related events. > [accordion] Events not generating > > Confirm that `Enable Event Streaming` is toggled on. Review threshold values to verify they match actual operating conditions. Check the routine status to confirm it is Enabled. ## Next steps > [card] [Routines](/products/fdd/routines) > > Create and test custom fault detection rules using the logic builder. > [card] [Routine logic blocks](/products/fdd/routine-logic-blocks) > > Explore the available logic blocks for building routine workflows. > [card] [FDD introduction](/products/fdd/overview) > > Review core FDD concepts including events, incidents, and faults. # FDD dashboards Source: https://docs.kodelabs.com/products/fdd/dashboards Monitor building health with interactive active and historical event dashboards featuring real-time metrics, trend charts, and filterable data views. FDD dashboards provide visual summaries of building health through interactive charts, metrics, and filterable data views. You can monitor both active and historical events from a single interface. `Active` shows open events only. `Historical` shows events in the selected timeframe and compares them to the previous equivalent window. > [!NOTE] > > Select a building from the [sites list](/products/kode-os/sites-and-map), then navigate to `FDD` > `Events` in the left sidebar. Select `Active` for the active events dashboard or `Historical` for the historical events dashboard. > [tab] Active > > The active events dashboard displays real-time fault data for your building. Use it to monitor ongoing events, identify priority areas, and track acknowledgment status. > > ### Filters and section toggles > > Use the filter bar at the top of the dashboard to narrow the displayed data. The available dropdown slicers include Areas, Routines, Priorities, Device Types, Ack Status, Domains, Work Order, and Users. Select `Clear All` to reset all filters. > > Select `Save` to save your current filter selections as your personal default. To apply saved filters for all users viewing this building, expand the `Save` dropdown and select `Save for Building`. > > Select the eye icon next to `Filters` to toggle individual dashboard sections on or off. > > ![Dashboard section toggle dropdown showing Building Summary, Routines Priority Domain, Device Types and Impact, Count and Duration Overview, Table View, and Assignees options](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-active-section-toggle.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=d8905fd23d2843ce8f317dbdd3222df8) > > Select the eye icon to show or hide individual dashboard sections > > > [!TIP] > > > > Hover over any data point for a tooltip with additional detail. Select a data point in one chart to filter related data across other widgets on the dashboard. > > ### Building summary > > The top of the dashboard displays key performance indicators for active events alongside an Affected Areas bar chart that ranks floors by event count. > > ![Active events dashboard showing summary cards for Ongoing Events, Ongoing Incidents, High Priority Events, Current Escalated Events, Affected Areas, Avg Duration, Ack'ed Ratio, and Avg Ack'ed Time, with an Affected Areas bar chart](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-active-dashboard.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=d5b4d087061ec7fe630d013a6b0eae41) > > Building Summary section with KPI cards and Affected Areas chart > > | Metric | Description | > | - | - | > | **Ongoing Events** | Total number of currently active events with percentage change | > | **Ongoing Incidents** | Total number of currently active incidents with percentage change | > | **High Priority Events** | Count of active events at Critical or Life Safety priority | > | **Current Escalated Events** | Events that have been escalated beyond initial response | > | **Affected Areas** | Number of distinct areas with at least one active event out of the total | > | **Avg Duration** | Average time events have remained active | > | **Ack'ed Ratio** | Percentage of active events that have been acknowledged | > | **Avg Ack'ed Time** | Average time between event creation and acknowledgment | > > ### Routines, priority, and domain charts > > These charts help you identify which routines generate the most fault activity and how events distribute by severity and domain. > > ![Routines horizontal bar chart showing event count and duration per routine, a Priority gauge chart with percentage breakdown by Critical, Warning, and Alert, and a Domains pie chart](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-active-routines-priority.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=c1b31fd383faada766372549cafc98bb) > > Routines bar chart with Priority and Domains charts > > * **Routines** bar chart shows event count and duration per routine. Bar height represents count and the overlaid line represents duration. > * **Priority** gauge chart breaks down active events by priority level with percentages. > * **Domains** pie chart breaks down active events by fault domain with percentages. > > ### Device types, impact, and resolution > > These charts show how faults distribute across device types, floors, and acknowledgment status. > > ![Affected Device Types donut chart, Relative Impact pie chart ranking floors by impacted device percentage, Resolution bar chart showing acknowledged versus unacknowledged counts, and Duration and Count Overview combo chart with per-floor counts and duration lines](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-active-device-impact.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=ff25d7e78910abb3467188346c52340f) > > Device Types, Relative Impact, Resolution, and Duration and Count Overview charts > > * **Affected Device Types** donut chart groups events by device type. Select a segment to filter other dashboard widgets. > * **Relative Impact** pie chart ranks floors by the percentage of impacted devices. > * **Resolution** bar chart shows the count of acknowledged versus unacknowledged events. > * **Duration and Count Overview** combo chart displays per-floor data: acknowledged/unacknowledged count, escalated/not escalated count, event duration line, and ack duration line. > > ### Table view and assignees > > The bottom of the dashboard provides a Table View and an Assignees table. > > ![Table View listing active events with columns for Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, Priority, Work Order URL, SLA, Area, and Ack'ed, with Events Incidents and Ack Mode toggles, followed by Assignees table showing per-user Incidents, Events, Ack'ed, Max Escalation, and Average Duration](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-active-table-assignees.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=45e333cab91dc80cd3aa52426300cc7e) > > Table View with event details and Assignees table with per-user metrics > > The **Table View** lists all active events in a filterable, sortable table. Switch between `Events` and `Incidents` views using the toggle at the top right. Select row checkboxes to bulk-acknowledge or create work orders from the footer. > > The **Assignees** table shows per-user assignment data. Each row displays a user with their incident count, event count, acknowledged count, max escalation level, and average event duration. > [tab] Historical > > The historical events dashboard displays fault data over a configurable time range. Use it to identify trends and evaluate building performance over days or weeks. > > ### Time range and filters > > Use the time range selector at the top right to choose the reporting period. The default is `Last 14 Days`. Select a different range to update all charts and metrics across the dashboard. Select `Pause Streaming` to freeze the current data view while you analyze the dashboard. > > The same filter bar, save options, and section toggles from the active dashboard are available here, along with two additional section options: `Count & Duration Trend` and `Operation Daily Overview`. > > ### Dashboard sections > > The historical dashboard includes the same sections as the active dashboard -- Building Summary, Routines/Priority/Domain, Device Types and Impact, Table View, and Assignees -- with all metrics calculated as daily averages over the selected time range. > > | Metric | Description | > | - | - | > | **Daily Avg Events** | Average number of events generated per day | > | **Daily Avg Incidents** | Average number of incidents generated per day | > | **Daily Avg High Priority Events** | Average high-priority events per day | > | **Daily Avg Escalated Events** | Average escalated events per day | > | **Daily Avg Affected Areas** | Average number of affected areas per day | > | **Daily Avg Duration** | Average event duration per day | > | **Daily Avg Ack'ed Ratio** | Average acknowledgment ratio per day | > | **Daily Avg Ack'ed Time** | Average time to acknowledgment per day | > > ### Count and duration trend > > The Count & Duration Trend chart shows daily event counts by priority as lines and average duration as bars. Use this chart to spot upward or downward trends in fault activity over the selected time range. > > ![Count and Duration Trend combo chart with daily bars for average duration and lines for Life-Safety, Critical, Warning, and Alert priority counts from May 6 to May 12 2026, followed by an Operation Daily Overview chart showing Events Number, Acked Events, and Escalated Events as horizontal bars](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-historical-trend-overview.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=01f1c9a211e68a4b07aeb972e1e01f0e) > > Count and Duration Trend chart showing daily event counts by priority and average duration > > ### Operation daily overview > > The Operation Daily Overview chart shows total events generated, acknowledged events, and escalated events per day. Use this chart to evaluate your team's response performance over time. > > ### Table and assignee views > > The historical table and assignee views function the same as their active dashboard counterparts. They display data for the selected time range instead of current active events. ## Next steps > [card] [Events](/products/fdd/events) > > Monitor and investigate real-time fault events across your building equipment. > [card] [Faults](/products/fdd/faults) > > Track recurring equipment issues and manage long-term maintenance priorities. # Events and incidents Source: https://docs.kodelabs.com/products/fdd/events Monitor, filter, and investigate FDD events and incidents with real-time streaming, device trends, and collaborative triage tools. The Events page displays fault events for your building and provides real-time monitoring, Stream Mode, and incident grouping. You can filter, search, acknowledge, create work orders, and investigate events from a single interface. > [!NOTE] > > Select a building from the [sites list](/products/kode-os/sites-and-map), then navigate to `FDD` > `Events` > `List` in the left sidebar. ## Events list The Events list page combines Stream Mode, priority filtering, and a sortable table. The page header provides controls for streaming, date range, and filters. ![Events page with sidebar showing Events List Active Historical and Faults navigation, Stream Mode control, Last 7 Days date picker, Filters button, priority summary cards for Total 297, Life-Safety 0, Critical 2, Warning 66, and Alert 229, and a Table View listing events with Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, and Ack'ed columns](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f2464097b2f7a916f2bd137070d7718b) The Events list shows priority summary cards, Stream Mode, and a sortable table with event details ### Stream Mode **Stream Mode** is a full-page Events console that inserts new building events at the top of the list in real time without manual refresh. Use it for passive monitoring on a command-center display, facility TV, or dedicated side monitor. Select **Stream Mode** to open the full-page stream view. New rows appear at the top automatically. Newly inserted rows highlight with a blue background for one to two seconds. Events less than one minute old show a **Just Now** badge under the start time. The highlight and badge clear as the event ages, and the start time updates to a normal timestamp. ![Entering and exiting Stream Mode on the Events list with the Event Stream table updating in real time](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-stream-mode.gif?s=2f4e8f2de891e7505c1063a72ee790d4) Enter Stream Mode for a full-page live feed, then exit when you need bulk actions | Behavior | Detail | | - | - | | **Sorting** | Locked to **Most Recent** so new events always appear at the top | | **Filters** | Filters applied before you enter Stream Mode stay active. You can also change filters while streaming | | **Priority counts** | Priority summary cards are hidden in Stream Mode to keep the feed responsive | | **Investigation** | Select a row to open the event report and triage | | **Bulk actions** | Exit Stream Mode before bulk acknowledge or [work orders per event](#create-work-orders-per-event) | Use the `Last 7 Days` date picker to set the time range for the list. Exit Stream Mode when you need custom column sorting, export, or multi-select bulk actions. ### Filters Select `Filters` at the top right to open the filter bar. ![Events page header showing filter dropdowns for Areas, Routines, Priorities, Device Types, Ack Status, Domains, Work Order, Event State, and Users, with Save and Clear All buttons, and priority summary cards for Total, Life Safety, Critical, Warning, Alert, and Info](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-filters.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=7c4b982d4bb2fa04f6a321819bdd735f) The filter bar provides dropdown slicers for narrowing events by area, routine, priority, and more The following dropdown slicers are available: | Filter | Description | | - | - | | **Areas** | Filter by floor or zone | | **Routines** | Filter by the routine that triggered the event | | **Priorities** | Filter by priority level | | **Device Types** | Filter by equipment type | | **Ack Status** | Filter by acknowledgment status | | **Domains** | Filter by fault domain (cooling, heating, etc.) | | **Work Order** | Filter by whether an event has a linked work order | | **Event State** | Filter by event state | | **Users** | Filter by assigned user | Select `Save` to save the current filter selection as your personal default. Expand the `Save` dropdown and select `Save for Building` to apply the filters for all users viewing this building. Select `Clear All` to remove all active filters. ### Priority summary cards Below the filters, a row of priority cards displays the event count by severity level: `Total`, `Life Safety`, `Critical`, `Warning`, `Alert`, and `Info`. These cards are interactive -- select a priority card to filter the table to that severity level. The count on each card updates dynamically as you apply or remove filters. ### Search Use the search bar above the table to find events by event name, device name, or building name. ## Events table The table view lists each event as a row with sortable columns. Click the up or down arrows on any column header to sort the table. | Column | Description | | - | - | | **Name** | Event name describing the detected condition | | **Device** | Device associated with the event | | **Device Type** | Equipment type | | **Point Name** | Data point that triggered the event | | **Point Value** | Value of the triggering point | | **Start Time** | When the event began | | **End Time** | When the event ended | | **Duration** | Total event duration | | **Priority** | Severity level | | **Work Order** | Linked work order status | | **SLA** | Service level agreement status | | **Area** | Floor or zone location | | **Building** | Building name | | **Assignees** | Users assigned to the event | | **Event ID** | Unique event identifier | | **Incident ID** | Linked incident identifier | | **Notified** | Whether notifications were sent | | **Ack'ed** | Acknowledgment status | Customize which columns appear and their order using the column configuration icon in the upper-right corner of the table. Pagination controls at the bottom let you configure the number of lines per page. Click any row to open the event report. ### Bulk acknowledge Select the checkboxes on the left side of the table to choose one or more events. Use Shift + click to select a range. A footer appears with `Acknowledge` and `Create Work Order` actions. Select `Acknowledge` to confirm. Based on your permissions, you may only be able to acknowledge events assigned to you. The count on the `Acknowledge` button shows how many of the selected events you can acknowledge. ### Create work orders per event Create **one work order per selected event** from the Events list. Select events with row checkboxes or the header select-all control. In the list footer, select `Create Work Order` (badged with the selection count). The button uses the same work order creation permission as a single-event work order. To put several events on a single work order, see [Group events into one work order](#group-events-into-one-work-order). Exit [Stream Mode](#stream-mode) before you multi-select. **1. Select events** Select the events that need field response. The footer shows `Acknowledge` and `Create Work Order` with the live selection count. **2. Review the batch** The review dialog lists one row per selected event with **Event Name**, **Device Name**, **Event ID**, and **Status**. Sort columns and page through the list as needed. Use the delete icon on a row to remove that event from the batch without returning to the table. These statuses describe the work order inside the bulk creation workflow. They are not the operational status of the work order in the destination CMMS. | Status | Meaning | | - | - | | **To Be Completed** | One or more required fields still need values. You cannot send the work order in this state. | | **Ready** | All required fields are populated. You can send the work order individually or include it in `Send Work Orders`. | | **Sent** | The work order was submitted successfully. You cannot edit or discard it within the bulk creation workflow. | | **Not Sent** | The work order was part of a submit-all action but was not submitted, usually because required fields were still incomplete. It remains available for review. When all required fields are populated, it becomes `Ready`. | **3. Choose Send Work Orders or Review Each** Select `Send Work Orders` to send every ready work order in one action. Select `Review Each` to open the standard work order form for the first event and walk the set one by one. **4. Edit in Review Each (optional)** The form uses the same fields as single-event creation (name, data source, entity, action, title, description, category, subcategory, location, device link, and priority). The header shows the event name, status chip, **Event N of M**, previous and next controls, and a dropdown to jump to any event in the batch. Use **Back** or **Back to Selected Events** to return to the review dialog. **5. Review outcomes and retry failures** After submission, the dialog reports **Sent** or **Not Sent** per row: * All succeeded — every selected work order was sent to the external system * Partial failure — some sent and some not sent; continue editing incomplete rows until they are `Ready`, then send again * Total failure — none were created; complete required fields and try again In the Review Each path, outcomes can also appear inline in the submission dialog. Successfully created work orders appear under [Generated Work Orders](/products/fdd/work-orders#work-order-view) with single-event work orders. > [!WARNING] > > Select `Cancel Creation` only when you intend to leave the flow. The **Discard Work Order Creation?** confirmation warns that unsaved progress and the current selection are lost. Choose `Keep Working` to stay in the flow. > [!NOTE] > > There is no bulk apply of category, priority, or location across the batch. Editing in Review Each is one event at a time. Failed submissions are not retried automatically. ### Group events into one work order Select two or more active events at the same building. In the list footer, select `Create Grouped Work Order`. KODE OS creates one work order that includes the selected events, labels each event, and links those events to the work order. When the work order closes, closure still applies to each event. You can still send a separate work order for each event with `Create Work Order`. Automated rules that reopen, hold, or cancel those work orders are configured under [Event triage rules](/products/fdd/settings#event-triage-rules). ### Export Exit Stream Mode before exporting. Select the download icon from the table toolbar to open the Export Options dialog. Configure the maximum number of rows (default 1,000), select the export type (`CSV` or `PDF`), and choose which columns to include. ![Export Options dialog showing Maximum number of rows set to 1000, Export type with CSV selected and PDF option, and a column selection list with checkboxes for Building, Priority, Name, Start Time, Duration, Event ID, Area, Device, Device Type, and End Time](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-export.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f73c79389e9324c5a582bee7257ad539) The Export Options dialog lets you select the format, row limit, and columns to include Any active filters also apply to the exported data. ### Full screen mode Select the full screen button in the upper-right corner to maximize the table view for a wider display. For continuous passive monitoring with automatic event insertion, use [Stream Mode](#stream-mode). ## Acknowledge events You need building access and the **Acknowledge FDD events** Write permission. FDD adds notification policy recipients as event assignees. The permission's `AssignedInEvent` constraint is enabled by default. With the constraint enabled, you can acknowledge only events assigned to you. An administrator can disable the constraint for a role that needs to acknowledge any accessible event, including historical events without an assignee. > [!TIP] > > Each event has one acknowledgment, not one per assignee. If someone else already acknowledged it, you do not need to acknowledge again. You can acknowledge from the event report header, from the Events list footer after selecting rows, or through the acknowledgment link in email notifications. If the **Acknowledge** button is unavailable, confirm your building access, role permission, and `AssignedInEvent` constraint. If the constraint is enabled, confirm that the event's [notification policy](/products/fdd/notification-policies) assigns the event to you. ## Event report Select an event from the table to open its report page. The event report provides automated trend charts, device context, and collaboration tools for investigating a single event. ![Event report for Temperature Greater than Setpoint while Occupied on FCU\_203, showing a Points Trend panel listing device points with live values, Combined Lines and Bars display mode tabs, a trend chart plotting Zone Temp Setpoint and Zone Temp over time, an Occupancy Command bar chart showing UnOccupied and Occupied periods, and a Reference Devices tab](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=5c0afc291616a8016b1de4510fe380ca) The event report shows the event name, device, trend charts with point selection, and display mode controls ### Event header The header displays the event name, device name, event ID, and assigned users as avatar icons. Select `Acknowledge` when your role and event assignment allow it. ### Device point trends FDD generates automated trend charts for the device associated with the event. Use the time range controls and date picker at the top right to adjust the visible window. Switch between display modes: | Mode | Description | | - | - | | **Combined** | All points on a single chart | | **Lines** | Each point displayed as a line on separate charts | | **Bars** | Bar chart format for discrete values | ### Point selection panel The Points Trend panel on the left lists all available points for the device with their live values. Search for specific points or check their checkbox to toggle visibility on the trend chart. Select `Show Selected` to display only checked points. Select `Clear Selection` to reset. Use the `Reference Devices` tab to view and overlay points from related devices. ## Event details sidebar The sidebar on the right side of the event report contains multiple sections accessible through icon tabs. Each tab provides a different layer of context for investigating the event. ### Details Displays core event information including the fault condition description, current state, priority level, triggering point name and value, timestamps, duration, and the affected device, area, and building. ![Event report for Temperature Greater than Setpoint while Occupied showing the Details panel with Description explaining setpoint and tolerance logic, Event State set to Closed, Priority set to Alert, Point Name showing Zone Temp, Point Value showing 23.60, Start Time and End Time timestamps, Duration of about 1 hour, and Device, Area, and Building fields](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-details.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=3ca3e0ac9d4cdd0087d500f543a11f31) The Details tab shows the fault description, event state, priority, point data, timestamps, and device location | Field | Description | | - | - | | `Description` | Explains the fault condition logic, including setpoint tolerance, occupancy, and delay behavior. Select `Show more` to expand the full description. | | `Event State` | Current state of the event (Active or Closed) | | `Priority` | Severity level assigned to the routine | | `Point Name` | The data point that triggered the event | | `Point Value` | The value of the triggering point at the time of the event | | `Start Time` / `End Time` | When the event began and ended | | `Duration` | Total event duration | | `Last Work Order` | Most recent work order linked to the event | | `Incident` | Linked incident identifier. Select to navigate to the incident report. | | `Device` | The device that triggered the event. Select to navigate to the device details page. | | `Area` | Floor or zone where the device is located. Select to navigate to the area page. | | `Building` | Building name. Select to navigate to the building overview. | ### Possible solutions Lists recommended actions to resolve the fault. Each solution is an expandable card that you can select to view detailed troubleshooting steps. ![Event report showing the Possible Solutions panel with four expandable solution cards: 1 - Verify Sensor Accuracy and Labeling, 2 - Inspect HVAC System Components, 3 - Review Historical Data and Operational Trends, 4 - Adjust HVAC System Settings](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-solutions.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=8c40487a3d66424f404f84c600c4664b) The Possible Solutions tab lists actionable troubleshooting steps for the detected fault ### Parameters Shows the tuning parameter values configured for the routine that generated the event. Each parameter card displays the parameter name, its current value, and a description of its function. ![Event report showing the Parameters panel with cards for start delay, heating and cooling setpoint tolerances, return-to-normal delay, alarm-on delay, and single-setpoint tolerance](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-parameters.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=b8180ef36a43d95dd2af7ac6d5d67ec7) The Parameters tab displays all configured tuning parameters with their current values and descriptions ### Historical Lists past occurrences of the same event on the same device. Each entry shows the date and time range. Select any historical entry to navigate to that event's report. Use this section to identify recurring patterns and assess whether the fault is intermittent or persistent. ![Event report showing the Historical panel with a list of previous event occurrences on dates including May 12, May 11, May 8, and March 20, 2026, each showing the time range of the event](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-historical.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=5e3977a16fcb52d60e29d7591eaa37d8) The Historical tab lists previous occurrences of the same event with date and time ranges ### Work orders Displays linked work orders for the event. Select `+` to [create a new work order](/products/fdd/work-orders#generate-a-work-order-from-an-event) directly from the event report. To create one work order for each of several events from the list, see [Create work orders per event](#create-work-orders-per-event). ### Referenced devices Lists related devices grouped by ontology relationship type (for example, `hasInputSubstance`, `isMeasuredBy`). Select a device to expand its point list and view live values. Check a point's checkbox to overlay it on the trend chart for comparison. Use the search bar and relationship filters to narrow the list. ![Event report showing the Referenced Devices panel with 4 related devices, relationship filters for hasInputSubstance and isMeasuredBy, and an expanded BTU\_L4\_HW device showing point values for Flow Rate, Heat Total Energy, Power, Return Water Temp, Supply Water Temp, Total Volume, Device Status, and Connector Status](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-referenced-devices.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c092f671a3f947873caf2993fdd12b3e) The Referenced Devices tab shows related devices with live point values that you can overlay on the trend chart ### Comments A shared space for team collaboration. Type a message in the text field and select the send button to post a comment. All team members with access to the event can view and reply to comments. ![Event report showing the Comments panel with a Type Here text input field and a send button](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-comments.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=817e35214407bfede946f9768632ea3e) The Comments tab provides a text input for adding notes and collaborating with team members ### Activity logs An audit trail of all actions and updates associated with the event. Each entry shows the action taken and a timestamp. Activity logs track event lifecycle changes such as creation, closure, acknowledgments, and status updates. ![Event report showing the Activity Logs panel with two entries: Event closed on May 12 at 5:49 PM and This event/incident is created on May 12 at 4:59 PM](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-activity-logs.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c9e437d99e838248f07ffcc6fa652365) The Activity Logs tab records all event lifecycle changes with timestamps ## Incidents view Switch to the `Incidents` view using the `Incidents` toggle above the table. Incidents group related events by finding commonalities through ontology relationships, reducing the number of individual issues you need to investigate. ![Events page with Incidents toggle selected showing a table with columns for Incident ID, Name, Building, Events, Areas, Priority, Devices, Start Time, End Time, Duration, Assignees, and Ack ID, with two incident rows displayed](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-incidents-list.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4a25da6d6a30bb93a2aa2a87ffa13390) The Incidents view groups related events with columns for Incident ID, Name, Building, Events count, Areas, Priority, Devices, Start Time, End Time, Duration, Assignees, and Ack ID FDD creates incidents using Reference Based Grouping. For example, if a VAV cannot meet its room temperature setpoint, the system checks whether the associated AHU or sibling VAVs also have active events. Related events are grouped under a single incident. ### Incidents table The incidents table lists each incident as a row. Search incidents by `Incident ID`, `Building`, or `Routines`. Click the expand icon on the right side of any row to reveal an inline incident summary without leaving the table. Click any row to open the full incident report. ### Incident report The incident report displays the incident ID in the header along with assignee avatars and an `Acknowledge` button for permitted users. Summary cards at the top show **Number of Events**, **Average Event Duration**, and **Affected Areas**. ![Incident report for incident 260509-87843 showing Number of Events 32, Average Event Duration About 5 hours, Affected Areas 6, a Status donut chart showing 100% Closed, an Areas bar chart with count and average duration per floor, Domains donut chart with Heating Issue and Cooling Issue, Device Types donut chart, and a Details sidebar with Incident State Closed, Priority Alert, Start Time, End Time, Duration about 9 hours, and Building](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-incident-report.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=8e1f885ff3915b585af8b168e1e2e008) The incident report shows summary metrics, status and area charts, domains and device type breakdowns, and a Details sidebar **Overview visualizations** display below the summary cards: | Widget | Description | | - | - | | **Status** | Donut chart showing the percentage of events by status (Closed, Active) | | **Areas** | Bar chart ranking affected areas by event count, with an overlaid line for average duration | | **Domains** | Donut chart breaking down events by fault domain | | **Device Types** | Donut chart breaking down events by equipment type | **Overall Impact** displays a timeline view of each routine involved in the incident. Color intensity represents the number of affected devices over time. Use the scrubber bar below to zoom into a specific time window. **Table View** lists all events contributing to the incident in a sortable table with columns for Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, and Ack'ed. Select any event row to open the event report. Select a device name to navigate to the device details page. ![Overall Impact timeline showing Damper Fully Open for Long Periods and Flow Less Than Setpoint routines across a time axis, followed by a Table View with columns for Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, and Ack'ed listing events across EVAV and SVAV devices](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-incident-impact-table.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=50aeb608ba514d6f1a89782f89fc71b8) The Overall Impact timeline and Table View list all events contributing to the incident Select `Select Points` to choose points across multiple devices for trend comparison. A trend chart appears below the table, plotting the selected points over time. ### Incident details sidebar The sidebar on the right side of the incident report contains three tabs accessible through icon buttons. **Details** -- displays core incident information: | Field | Description | | - | - | | `Incident State` | Current state of the incident (Active or Closed) | | `Priority` | Severity level of the incident | | `Start Time` | When the incident began | | `End Time` | When the incident ended | | `Duration` | Total incident duration | | `Building` | Building name (select the edit icon to reassign) | **Comments** -- a shared space for team collaboration. Type a message and select the send button to post a comment. ![Incident sidebar showing the Comments tab with a Type Here text input field and a send button, alongside icon tabs for Details, Comments, and Activity Logs](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-incident-comments.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=77a187115936091b8571c51dab1d04db) The Comments tab provides a text input for notes and team collaboration on the incident **Activity Logs** -- an audit trail of all actions associated with the incident. Each entry shows the action taken and a timestamp. ![Incident sidebar showing the Activity Logs tab with two entries: All events are closed so incident is closed too on May 9 at 5:17 PM, and Merged Flow Less Than Setpoint Flow Less Than Setpoint to create this incident on May 9 at 8:45 AM](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-incident-activity-logs.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=2ffcd2cb8277d379002cb369fce5df72) The Activity Logs tab records incident lifecycle changes such as creation and closure ## Advanced use cases ### Subsystem alarm ingestion and writeback > [!NOTE] > > Subsystem alarm ingestion and acknowledgment writeback are limited-release capabilities. They are not available on all environments. Contact your KODE representative if your organization needs this workflow. KODE OS can ingest native alarms from connected subsystems through [data sources](/products/kode-os/data-sources). This brings BMS and other subsystem alarms into the same Events workflow as routine-generated faults. Operators can view, acknowledge, comment on, and create work orders without switching to the source console. Niagara is the first supported connector. Additional subsystems will use the same normalized alarm structure in future releases. #### Capabilities | Capability | Description | | - | - | | **Alarm visualization** | Alarms enabled in the source system appear in KODE when alarm ingestion is configured on the connector | | **Bi-directional acknowledgment** | Acknowledging an alarm in KODE writes back to the source system. Acknowledgments in the source sync to KODE | | **Trend context** | Device trend data appears on the event report when available for the associated equipment | | **Comments and SLA** | Use the same collaboration tools and SLA tracking as routine-generated events | | **Work orders** | Create work orders directly from subsystem alarm events | #### Current limitations V1 imports all alarms enabled in the source system. Selective filtering by priority, domain, or alarm name is not available yet. [Notification policies](/products/fdd/notification-policies) do not route email, SMS, or push alerts for subsystem alarms in V1. KODE does not show inline confirmation when acknowledgment writeback succeeds or fails. FDD routines and subsystem alarms run in parallel. Alarm ingestion does not replace FDD routines. #### Acknowledgment writeback **Ack writeback** sends an acknowledgment from KODE back to the source subsystem when you acknowledge an alarm on the Events list or event report. This keeps both systems in sync and helps prevent unacknowledged alarms from accumulating in the BMS queue. Acknowledgments made in the source system also appear in KODE. See [Acknowledge events](#acknowledge-events) for list and report workflows. ## Next steps > [card] [Faults](/products/fdd/faults) > > Track recurring equipment issues and manage long-term maintenance priorities. > [card] [FDD dashboards](/products/fdd/dashboards) > > View building health at a glance with active and historical event dashboards. > [card] [Configuration](/products/fdd/configuration) > > Set up monitoring rules and parameters for your building equipment. > [card] [Data sources](/products/kode-os/data-sources) > > Configure connectors used by limited-release subsystem alarm ingestion. # Faults Source: https://docs.kodelabs.com/products/fdd/faults Track recurring equipment issues, analyze fault patterns across devices and routines, and manage long-term maintenance priorities. Faults capture long-term or recurring issues across your building equipment. Use the `Faults` page to monitor patterns, prioritize maintenance, and track resolution over time. > [!NOTE] > > Faults is a building-level module. Select a building from the sites list, then navigate to `FDD` > `Faults` in the left sidebar. ## Access from device details Open any device and select the `Trends` tab. Click `Faults` in the summary bar to review recent faults for that equipment in the **FDD Faults** sidebar. See [View faults from trends](/products/kode-os/devices/devices#view-faults-from-trends). Faults are generated daily when `Fault Config` is enabled in the [Status Setup](/products/fdd/configuration#configure-routines) section of a routine's configuration. They analyze non-critical comfort, energy, and mechanical issues. To create faults, you first define a monitoring [routine](/products/fdd/routines), then [configure](/products/fdd/configuration) it with `Fault Config` enabled. ## Watcher notifications Faults send email notifications to assigned watchers when any of the following occur: * Status update * New comment * New watcher (notifies only the newly added watcher) Notifications use a five-minute rolling delay. Each watcher-relevant change resets the window. After five minutes with no further changes, FDD sends one email that summarizes the updates in that window. For example, if changes occur at minute 1, minute 3, and minute 7, relevant watchers receive a summary email at the 12-minute mark. ![KODE Labs email notification with subject There is a new update on the fault you are assigned to, View Fault List button, greeting Hi Michael You have 1 comment, New Comments section stating There is 1 new comment on 1 fault you are watching, and a listed fault VAV\_2-Sensor Failure Stale Discharge Air Temperature](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-watcher-email.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=97f3b84b305c6c59cb45230d1fc01a1a) Watcher email summarizing new comments on faults you are watching ## Faults landing page The `Faults` page provides three views to organize fault data: | View | Description | | - | - | | **List** | Individual faults displayed as separate rows | | **Device** | Faults grouped by device | | **Routine** | Faults grouped by monitoring routine | ## List view The list view displays one row per fault. Status tabs at the top show counts for `Open`, `In Progress`, `Resolved`, `Deferred`, `In Review`, and `Suppressed` faults. Use the date picker at the top right to select a time range (up to 30 days) and select `Filters` to open the filter bar. ![Faults page showing filter dropdowns for Areas, Device Types, Routines, Domains, Status, Labels, and Watchers, Clear All button, status tabs for Open 1770, In Progress 0, Resolved 0, Deferred 0, In Review 0, and Suppressed 0, a Last 14 Days date picker, and a Table View with columns for Device, Routine, Status, Occurrences, Duration, and Time in Fault per Day](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=3d09ab007c63b412602b3be8009731d9) The Faults list view shows filter dropdowns, status tabs with counts, a date picker, and a sortable table Hover over the `Time in Fault per Day` column to see a tooltip with the event count and total hours in fault for a specific day. The list view displays the following columns: | Column | Description | | - | - | | **Device** | The device associated with the fault | | **Routine** | The monitoring routine that triggered the fault | | **Status** | Current status: `Open`, `In Progress`, `Resolved`, `Deferred`, `In Review`, or `Suppressed` | | **Occurrences** | Number of events generated by this fault | | **Duration** | Cumulative time the fault has been active | | **Time in Fault per Day** | Visual bar indicator of daily fault duration | | **Watchers** | Users monitoring this fault | | **Labels** | Tags such as `Reopened`, `Overdue`, or `Work Order` | | **Last Comment** | Most recent comment on the fault | | **Last Activity** | Timestamp of the most recent action | | **Area** | Building area where the device is located | | **Work Order URL** | Link to the associated work order | ### Filter and search faults Select `Filters` to open the filter bar with dropdown slicers for `Areas`, `Device Types`, `Routines`, `Domains`, `Status`, `Labels`, and `Watchers`. Select `Clear All` to reset all filters. > [!TIP] > > Combine filters to focus your view. For example, filter by `Open` status and a specific routine to see all unresolved faults for that monitoring rule. Search faults by device name or routine name using the search bar. ### Bulk actions Select one or more faults using the checkboxes on the left side of the table. A bulk action toolbar appears at the bottom with the following options: * `Cancel` -- deselect all faults * `+ Add Watchers` -- assign watchers to the selected faults * `+ Add Comment` -- add a comment to all selected faults * `Update Status` -- change the status of all selected faults at once ![Faults table with three faults selected via checkboxes showing Device, Routine, Status, Occurrences, Duration, and Time in Fault per Day columns, pagination showing Pages 36 and Lines per page 1-50 of 1770, and a bulk action toolbar at the bottom with Cancel, Add Watchers, Add Comment, and Update Status buttons](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-table.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=3666cb3f40b34b4bbaac9ad1743e4cbb) Select multiple faults to access bulk actions for status updates, watchers, and comments ### Export Select the download icon to export the filtered list as a CSV file. Fault metrics such as total duration and occurrences are computed based on the selected date range. ### Fault report Select any fault row to open the fault report. The report header displays the fault name, device name, date picker, status dropdown, and a `Watchers` control to add or view users monitoring the fault. The report contains two tabs: `Details` and `Activity Log`. ![Fault report for Sensor Failure Stale Discharge Airflow Sensor on VAV\_9\_10 showing a Details tab and Activity Log tab, View Points button, Combined Lines and Bars display mode tabs, a trend chart plotting Discharge Air Flow over a Last 14 Days range with red shaded fault periods, and a Details sidebar showing Description, Occurrences 4, Avg Duration 8 hrs, Daily Avg Occurrences 0.29, Last Comment, Last Activity, Last Work Order, Area Floor 9, and Device Report](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=ad3c2c5af1e791cf5c1a632add859f0c) The fault report shows the fault name, device, trend chart with display modes, and a Details sidebar #### Points trend view The Points Trend panel on the left lists all available points for the device with their live values. Search for specific points or check their checkbox to toggle visibility on the trend chart. Select `Show Selected` to display only checked points. Select `Clear Selection` to reset. Use the `Reference Devices` tab to view and overlay points from related devices. ![Fault report for Sensor Failure Stale Discharge Airflow Sensor on VAV\_9\_10 showing a Points Trend panel listing device points with live values including AirFlSptHtg, ClgTLoad, Device Mode set to Deadband, Discharge Air Flow at 0 L/s, and more, alongside a trend chart plotting Discharge Air Flow over a Last 14 Days range with red shaded fault periods, and a Device Mode bar chart showing Deadband and Heating states](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-points-trend.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=91938f1d55b86e67da86d72de54b0117) The Points Trend panel lists device points with live values alongside the trend chart with display mode controls Red shaded regions on the trend chart highlight the periods when fault events were active. Switch between display modes: | Mode | Description | | - | - | | **Combined** | Overlay of all points on a single chart | | **Lines** | Line chart for continuous data | | **Bars** | Bar chart format for discrete values | #### Table view Below the trend chart, a table lists each event associated with the fault. Search events using the search bar. Each row is expandable for additional detail. ![Fault report showing the Table View with columns for Event Name, Duration, Start Time, and End Time listing four occurrences of Sensor Failure Stale Discharge Airflow Sensor each with 8 hours duration, pagination showing Pages 1 and Lines per page 1-4 of 4, and a Details sidebar on the right](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-table-view.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=98268254f0444ad9aa5dd3e7fda77266) The Table View lists all events associated with the fault with duration, start time, and end time | Column | Description | | - | - | | **Event Name** | Name of the contributing event | | **Duration** | How long the event was active | | **Start Time** | When the event began | | **End Time** | When the event ended | #### Fault details sidebar The sidebar on the right side of the fault report contains multiple tabs accessible through icon buttons. **Details** -- displays core fault information: | Field | Description | | - | - | | `Description` | Explains the fault condition logic | | `Occurrences` | Number of events generated by this fault | | `Avg Duration` | Average duration of individual fault events | | `Daily Avg Occurrences` | Average number of fault events per day | | `Last Comment` | Most recent comment on the fault | | `Last Activity` | Timestamp of the most recent action | | `Last Work Order` | Most recent work order linked to the fault | | `Area` | Floor or zone where the device is located. Select to navigate to the area page. | | `Device Report` | Select to navigate to the device details page. | **Possible Solutions** -- lists recommended actions to resolve the fault. Each solution is an expandable card with detailed troubleshooting steps. ![Fault report showing the Possible Solutions panel with three expandable solution cards: 1 - Verify Sensor Functionality, 2 - Review Historical Data, 3 - Check Upstream System Operation](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-solutions.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=3bf362c15822a3cc2d492ace894215f1) The Possible Solutions tab lists actionable troubleshooting steps for the detected fault **Parameters** -- shows the tuning parameter values configured for the routine that generated the fault. Each parameter card displays the parameter name, its current value, and a description. ![Fault report showing the Parameters panel with cards for Off Delay in minutes (1), Min Sensor Failure Duration (72) showing how many hours the sensor needs to flatline before the event is generated, and Start Delay in Minutes (1)](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-parameters.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=e1bae1abb1c335624dd605fb8858a07e) The Parameters tab displays configured tuning parameters with their current values and descriptions **Comments** -- a shared space for team collaboration. Type a message and select the send button to post a comment. ![Fault report showing the Comments panel with a Type Here text input field and a send button](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-comments.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=816dc3c08a2f84cf105089ec17c9cf8b) The Comments tab provides a text input for notes and team collaboration on the fault **Work Orders** -- displays linked work orders with an option to create new ones. **Referenced Devices** -- lists related devices grouped by ontology relationship type. Select a device to expand its point list and view live values. Check a point's checkbox to overlay it on the trend chart for comparison. ![Fault report showing the Referenced Devices panel with 1 related device, an isFedBy relationship filter, Show Selected and Clear Selection controls, and an expanded CU\_09 device showing point values for BioHazard, BuildingPr, Chilled Water Valve Percent Cmd, CO2\_Select, CO2Spt, Discharge Air Press, and Discharge Air Press Setpt](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-referenced-devices.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=58f74e0747cb84197b4f48a48ec1d6b0) The Referenced Devices tab shows related devices with live point values that you can overlay on the trend chart ## Device view The device view groups faults by device. Each row represents a single device with aggregated fault data. The same status tabs, date picker, and filter controls from the list view are available. ![Faults Device view showing status tabs for Open 104, In Progress 0, Resolved 0, Deferred 0, In Review 0, and Suppressed 0, a Last 14 Days date picker, and a table with columns for Device, Fault Count, Duration, Time in Fault per Day, and Area listing VAV devices across multiple floors with pagination showing Pages 3 and Lines per page 1-50 of 104](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-device-view.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=5621ff8fa21cbada91d09733502edcc8) The Device view groups faults by device with Fault Count, Duration, Time in Fault per Day, and Area columns | Column | Description | | - | - | | **Device** | The device name | | **Fault Count** | Number of distinct faults for this device | | **Duration** | Cumulative fault duration across all faults | | **Time in Fault per Day** | Visual indicator of daily fault duration | | **Area** | Building area where the device is located | Select any device row to open the device fault report. The report header displays the device name, area, and a date picker. Summary cards show **Total Nr Of Events**, **Daily Average Nr Of Events**, **Average Duration**, and **Affected Routines**. ![Device fault report for VAV\_4\_47 on Floor 4 showing Total Nr Of Events 2, Daily Average Nr Of Events 0.29, Average Duration 14hrs, Affected Routines 1, a Routines timeline showing Sensor Failure Stale Discharge Airflow Sensor with Normal and fault periods, a Points Trend panel listing device points with live values, and a trend chart plotting Discharge Air Flow over a Last 14 Days range](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-device-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=64d4dc512ebf9c180b0b33e336eabb8f) The device fault report shows summary metrics, a Routines timeline, Points Trend panel, and trend chart The **Routines** section shows a timeline for each affected routine. Green indicates normal operation and red/orange indicates fault periods. Below the routines timeline, the Points Trend panel and trend chart function the same as the [fault report](#points-trend-view). A Table View at the bottom lists the individual faults for the device. ![Table View showing a single fault row for Sensor Failure Stale Discharge with Status Open, Occurrences 2, Duration 1 day, Time in Fault per Day bar chart, Watchers, and Labels columns](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-device-table.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=8be565c2a1a720e1fdbfc71ed2faa995) The Table View within the device report lists individual faults with their status, occurrences, and duration ## Routine view The routine view groups faults by monitoring routine. Each row represents a single routine with aggregated fault data. The same status tabs, date picker, and filter controls from the list view are available. ![Faults Routine view showing status tabs for Open 104, In Progress 0, Resolved 0, Deferred 0, In Review 0, and Suppressed 0, a Last 14 Days date picker, and a table with columns for Routine, Device Count, Duration, Time in Fault per Day, and Area listing Sensor Failure Stale Discharge Airflow Sensor with 104 devices and 573 days duration](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-routine-view.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=54af013a87e710587e0ea01cd2ce7dbc) The Routine view groups faults by routine with Device Count, Duration, Time in Fault per Day, and Area columns | Column | Description | | - | - | | **Routine** | The monitoring routine name | | **Device Count** | Number of devices affected by this routine | | **Duration** | Cumulative fault duration across all devices | | **Time in Fault per Day** | Visual indicator of daily fault duration | | **Area** | Building area | Select any routine row to open the routine fault report. The report header displays the routine name and a date picker. Summary cards show **Total Nr Of Events**, **Daily Average Nr Of Events**, **Average Duration**, and **Affected Devices**. ![Routine fault report for Sensor Failure Stale Discharge Airflow Sensor showing Total Nr Of Events 354, Daily Average Nr Of Events 33.71, Average Duration 2days, Affected Devices 104, a Time in Faults combo chart with Nr of Events bars and Hours line over a Last 14 Days range, an Affected Areas bar chart showing Floor 4, Floor 7, and Ground Floor percentages, and a Device Types chart](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-routine-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=389269570a112bbc7f6b8f97805cc748) The routine fault report shows summary metrics, a Time in Faults trend, and Affected Areas and Device Types charts The **Time in Faults** chart displays the number of events as bars and total fault hours as a line over the selected time range. Below, **Affected Areas** and **Device Types** charts show the distribution of faults by floor and equipment type. A Table View at the bottom lists the individual faults for the routine, with columns for Device, Routine, Status, Occurrences, Duration, Time in Fault per Day, and Watchers. ![Table View listing device faults for the routine with columns for Device, Routine, Status showing Open, Occurrences, Duration, Time in Fault per Day, and Watchers, with devices including VAV\_9\_10, VAV\_4\_01, VAV\_4\_04, VAV\_9\_39, and more, pagination showing Pages 3 and Lines per page 1-50 of 104](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-faults-routine-table.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=e5405ef8275d061ec15490d5986932d1) The Table View within the routine report lists individual device faults with status, occurrences, and duration ## Next steps > [card] [Events](/products/fdd/events) > > Monitor and investigate individual fault events in detail. > [card] [Configuration](/products/fdd/configuration) > > Set up monitoring rules and parameters for your building equipment. > [card] [Dashboards](/products/fdd/dashboards) > > View building health at a glance with FDD dashboards. # KODE glossary Source: https://docs.kodelabs.com/products/fdd/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Handling FDD updates Source: https://docs.kodelabs.com/products/fdd/handling-updates Understand how changes to FDD configurations, devices, points, and routines affect active events, incidents, and monitoring behavior. Changes to FDD configurations, devices, points, and routines trigger specific system behaviors. All changes are tracked for transparency and troubleshooting. > [!WARNING] > > Always check if the specific point or device is part of any active FDD config before making changes or deletions. If it is, deselect it from the config first, or confirm that it is not in use. Failing to do this can cause FDD configs to gray out, trigger unwanted alarms, or leave active events that must be manually cleared. ## Activity log Every update to configs is recorded at the building level. The log shows what was changed, who changed it, and when it was changed. ## Automatic actions on config changes When a config is deleted or disabled: * Any related active events or active incidents are automatically closed * If an incident has no other active linked FDD configs or events, it is closed ## Device and point changes Devices and points are managed through the Config Details page, where you select or deselect devices for each routine and configure parameters in the right panel. ![Config Details page for Temperature Greater than Setpoint while Occupied showing folder tabs for All, Folder 1, and Folder 2, a device table with checkboxes listing devices like VAV\_207, FCU\_403, and VAV\_302 with their areas and point counts, and a Routine Params panel on the right showing Arbitrary Heating Setpoint 66, Alarm On Delay 1, Arbitrary Cooling Setpoint 75, Start Delay 30, Heating Setpoint Deadband 1.50, and Cooling Setpoint Deadband 1.50](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-details.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=dff7fd82cd3e097562ed3ade77200340) The Config Details page shows selected devices and routine parameters that are affected by device or point changes ### Update a point or device When a point or device is updated (for example, an ontology field is changed), the system checks if it is being used in any FDD configs. If the device or point becomes incompatible: * The related configs are grayed out * Any active alarms or events linked to it remain active until the device or point is removed from the config If the point still exists in Cloud BMS but is untemplated, the config can still trigger alarms when its conditions are met, even if the point or device appears grayed out in the config. To remove an incompatible point or device: * Delete and recreate the config, or * Restore the device or point to its previous ontology fields, open the config, deselect the device or point, and save changes > [!TIP] > > Always deselect the device or point from the FDD config before making changes, or confirm it is not part of any active config. ### Delete a point or device When a point or device is deleted, the system checks if it is used in any FDD configs. Related configs gray out after device or point deletion. If an alarm was already generated for the deleted point or device, it remains active in the FDD list. If only some points of a config are deleted: * The config grays out and does not trigger events if the missing point is required for alarms * Already-triggered alarms remain active for the deleted devices or points To clear active events from deleted points or devices, delete and re-enable the FDD config. > [!TIP] > > Always deselect the device or point from the FDD config before deleting them. ### Update names If an FDD config is enabled and the building, device, or point name changes, the updated name does not appear for: * Already-triggered events * New events from existing configs Only FDD configs enabled after the change display updated names. ## Parameter updates If parameters for an enabled FDD config are changed while it has already-triggered active events: * The currently active event remains active under the old parameters * FDD does not retroactively update or close events when parameters are changed * Once the active event ends, the updated parameters are applied for future event creation > [!TIP] > > Before adjusting parameters, review active events linked to the config so you can track which are still running under the old conditions. ## Config actions The Configs list shows the current status of each routine. Batch actions at the bottom of the page let you delete, disable, enable, or configure multiple routines at once. ![Batch Configuration page showing a table with routines like Temperature Greater than Setpoint while Occupied with Event Status Enabled and Fault Status Not Configured, expanded to show Folder 1 with 78 devices and Folder 2 with 1 device, and additional routines in Not Configured status, with Delete, Disable, Enable, and Configure action buttons at the bottom](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-configs-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=b083f86751256517c188916f9d392799) The Configs list shows routine statuses and Multi-Config folders, with batch action buttons at the bottom | Action | Behavior | | - | - | | **Disable** | Config is disabled and all linked events and incidents are closed | | **Enable** | Config is activated and events trigger after alarm conditions are met | | **Update** | Changes are saved and recorded in the system | ## Routine updates ### Update canonicals or entities If an FDD routine's configs are enabled and you add or remove canonicals or entities, or change selected points in logic blocks from the routine, the FDD config changes from `Enabled` to `Unconfigured`. ![Add Devices dialog with Name As set to Base, a Canonicals section showing selectable tags for fcu, vav, ahu, fan, radiantDevice, and uh, and an Entities section showing selectable tags for OM, ZTS, ZTSS, CLGUM, COUNTER, CSM, DAF, DFC, DFCS, DFEN, DFFREQ and more, with Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-add-devices.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b3d5efab3bf591b83fbab980d599af0a) Canonicals and Entities are defined in the routine's Add Devices dialog -- changes here affect all linked configs Changing selected points in logic blocks also triggers the config to become `Unconfigured`. ![Select Field dialog in the Logic tab showing a Base dropdown expanded with Required Fields listing occupied\_mode and run\_status as selectable options, with Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-select-field.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9f091ec30310f79dac03934dd28cd8f2) The Select Field dialog in the Logic tab shows the required fields that, if changed, reset linked configs to Unconfigured ### Delete a routine A deleted local FDD routine is removed across the portfolio. All FDD configs linked to it are deleted. Any active events linked to it are deleted. > [!WARNING] > > Deleting a routine is irreversible and affects every building in the portfolio that uses it. Verify linked configurations before proceeding. ## Next steps > [card] [Configuration](/products/fdd/configuration) > > Set up and manage fault detection rules and monitoring parameters. > [card] [Routines](/products/fdd/routines) > > Create and test custom fault detection rules using the logic builder. > [card] [Events](/products/fdd/events) > > Monitor and investigate real-time fault events across your building equipment. # Notification policies Source: https://docs.kodelabs.com/products/fdd/notification-policies Create and manage notification policies to control how FDD delivers alerts through email, SMS, and push notifications. Notification policies define how, when, and to whom FDD sends alerts. Each policy controls the notification channels, message content, recipient list, and return-to-normal behavior for events. ## Policies list To access notification policies, navigate to `FDD` > `Policies`. The Policies page displays all configured policies in a sortable table. ![Policies list showing configured notification policies with name, description, type, and completion status](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policies-list.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=1b81bed31fc15208122beaefd8d51387) The table includes the following columns: | Column | Description | | - | - | | **Name** | The policy name | | **Description** | A summary of the policy's purpose | | **Type** | `Building` or `Portfolio` scope | | **Completion** | Whether the policy configuration is complete | Use the search bar to filter policies by name or description. Select `Filters` to narrow results by specific criteria. > [!NOTE] > > Edit a policy at the same level where it was created. Edit portfolio policies in Portfolio view and building policies in the Building view. ### Manage policies Select the three-dot menu on any policy row to access row actions. ![Policy row actions showing Edit Policy, Duplicate Policy, and Delete Policy options](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policies-row-actions.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=6c47873ed8b3a2a84b4c468927ab044b) * **Edit Policy**: Open the policy wizard to modify settings. * **Duplicate Policy**: Create a copy of the policy with the same configuration. * **Delete Policy**: Remove the policy permanently. ## Create a policy Select `+ Create Policy` to open the policy wizard. The wizard has two steps: **Details** and **Notify**. ### Step 1: Details The Details step defines the policy name, notification channels, and content. ![Policy creation wizard showing Details step with name, description, auto close, email and SMS channels, and return to normal toggle](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policy-create-channels.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=acf59e01e2d95a141f4bb4b968b4c6d0) The Details step with notification channel configuration #### Policy information * **Name**: Enter a descriptive name that identifies the policy's purpose, such as "Critical HVAC - Engineering Team." * **Description**: Provide a brief summary of when and why this policy is used. #### On Create The `On Create` section controls what happens when a new event is generated. **Auto Close After** sets how long an event stays active before automatically closing. The default value is `Never`, which keeps events open until they are manually resolved or the fault condition clears. #### Notification channels Each channel can be expanded to configure its notification type and content. The available channels are: * **Email**: Send structured email notifications with event details. * **Push**: Send in-app push notifications to mobile devices. * **Sms**: Send text message notifications with event information. #### Email notification options For each email channel, select one of two notification types from the `Notification` dropdown: **Default** uses the standard KODE email template. When you select Default, choose the fields to include in the email from the `Fields` multi-select dropdown. The available fields are: * Building * Client Name * Device Name * Event Description * Event Name * Event Note * Event Status * Floor * Location * Next Escalation * Point Name * Point Value * Possible Solution * Priority * Routine Description * Routine Name * Start Time The default email template displays an "Event Created" header, the selected field values in an event summary, and a `View event` button that links directly to the event in Cloud BMS. ![Default email template showing Event Created header, event summary with building name, and View event button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policy-email-preview.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=09490ec966b124c1ce7e670646614075) Default email template preview for event creation notifications **Custom Email** lets you customize the email subject line and select which fields to include. When you select Custom Email, configure: * **Fields**: Choose which data fields appear in the email body from the same field list as Default. * **Subject**: Define a custom subject line using dynamic tokens. The default subject pattern is `Event {{status}} - {{building.name}} - {{devices.name}} - {{name}}`. Select from the available subject tokens to insert dynamic values: Building, Client Name, Device Name, Event Description, Event Name, Event Note, Event Status, Floor, Location, Next Escalation, Point Name, Point Value, Priority, Routine Description, Routine Name, and Start Time. #### Return to normal The `Return to Normal` toggle controls whether a notification is sent when a fault condition clears and the event ends. When enabled, the return-to-normal section provides the same channel configuration (Email, Push, Sms) as the On Create section. ![Return to Normal section enabled, showing email notification with Default selected, subject line, available tokens, and Event Closed email template preview](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policy-return-to-normal.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=e11d1ebb4ce0190d97688740b550c30c) Return to Normal configuration with the Event Closed email template The return-to-normal email template displays an "Event Closed" header with a green accent line and includes a `Click here to acknowledge event!` button. The available fields for return-to-normal notifications include two additional options beyond the On Create fields: * Duration * Ended At ### Step 2: Notify The Notify step defines the recipients, escalation tiers, and external data sources for the policy. The page is organized into collapsible sections. #### External Data Source Select `+ Add` to connect an external data source for work order delivery from this policy. This section is optional. When you configure an external data source at the policy level, it applies to every configuration that uses this policy. A configuration-level external data source [overrides the policy setting](/products/fdd/configuration) for that configuration only. #### Details Choose one of two recipient configurations: **Group Configuration** assigns the same notification channels to all selected recipients. ![Notify step showing Group Configuration with roles, specific users, escalation tiers, and notification channel checkboxes](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policy-notify-group.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=fb92ec7e2b5b27d87d9e974b1fc91ad0) Group Configuration with roles, specific users, and shared notification channels * **Roles**: Select one or more roles (for example, `01 - System Admin`, `05 - Engineering`). * **Specific Users**: Select individual users to receive notifications. * **Notifications**: Enable one or more channels for all recipients: `Push`, `Email`, `SMS`, and `Call`. **Custom Configuration** lets you assign different notification channels to each role or user individually. ![Notify step showing Custom Configuration with individual role and user rows, each with their own notification channel selection](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-policy-notify-custom.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=04e0e829be3cdbf9fb85896f7814d4d8) Custom Configuration with per-recipient notification channel assignments * Select `+ Add User` or `+ Add Role` to add recipients. * For each recipient row, choose the notification channels from the `Notifications` dropdown (for example, `Email, Call` for one role and `Push, Email, Call` for a specific user). * Select the red X icon to remove a recipient row. #### Escalation tiers Add escalation tiers to notify additional recipients if events remain unresolved. * **1st Escalation**: Set the `Duration in minutes` before escalation triggers. Assign `Roles` and `Specific Users` for this tier with their own notification channels. Select `Delete` to remove the tier. * **2nd Escalation**: Select `+ Add` to configure a second escalation tier with the same options. Each escalation tier supports the same Group or Custom Configuration options as the Details section. > [!NOTE] > > Users you add in the **Notify** step become event assignees when FDD sends a notification. By default, the `AssignedInEvent` role constraint limits acknowledgment to these assignees. Administrators can disable the constraint for roles that need broader acknowledgment access. Select `Save` to create the policy. ## Assign a policy You can assign policies at two levels: * **During routine configuration**: Select routines from the Configs list, select `Configure`, and choose the policy from the dropdown. * **During event review**: Update the policy assigned to a specific event from the event details panel. > [!NOTE] > > Policies assigned at the routine level apply to all future events generated by that routine. Event-level assignments override the routine default for that specific event. ## Notification behavior FDD sends notifications at specific points in the event and incident lifecycle: * **Event Created**: A notification is sent when a new event is generated. The subject line follows the pattern "Event Created - Event Name." * **Incident Created**: When related events merge into an incident, a single notification is sent. * **Incident Priority Changed**: When the incident priority escalates (for example, from Alert to Warning to Critical), a notification is sent at each level. An incident inherits the notification policy of its highest-priority event. FDD sends a maximum of three notification types per incident, which limits notification volume even when hundreds of faults are active. ### Channel behavior Each notification channel delivers event information in a format suited to the channel: * **Email**: Structured email with event summary fields, a `View event` link, and a `Click here to acknowledge event!` button. When an event closes and return-to-normal is enabled, the email displays an "Event Closed" header with a green accent. * **Push**: In-app push notifications. You can insert dynamic tokens such as `View Event Link` and `Acknowledge Event Link`. The preview shows placeholders such as `URL` and `ackURL`. * **SMS**: Text message notifications. You can insert the same dynamic tokens as Push. * **Call**: An automated voice call that reads out the event details. Call content cannot be customized. ![Cloud BMS email notification showing Event Closed status with green checkmark, Event Summary including Event Name AlmHWPmp5, Event Description Hot Water Pump 5 Alarm has Returned To Normal, Routine Name MDAS High priority, Device Name HW\_Pump\_5, Point AlmHWPmp5, Point value true, Start time and End time November 15 2022, Duration 1m, Priority Critical, Floor N/A, and a Click here to acknowledge event button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-notification-email.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=de7a2d69f167c003835fc3c4ebe07eb7) A return-to-normal email notification showing the Event Closed status with event summary details ### Acknowledge behavior FDD adds policy recipients as event assignees when it sends a notification. With the default `AssignedInEvent` constraint, only these assignees can acknowledge the event. If an administrator disables the constraint for your role, you can acknowledge any event you can access. If acknowledgment controls are unavailable, confirm your building access and **Acknowledge FDD events** Write permission. When `AssignedInEvent` is enabled, also confirm that the policy's **Notify** step assigns the event to you. Recipients must also have access to the building where the event occurs. Without building assignment, they do not receive notifications and cannot acknowledge events. When an assignee acknowledges an event through the notification link or in Cloud BMS, subsequent assignees who select the acknowledge button receive a message indicating the event has already been acknowledged. ## Next steps > [card] [Configuration](/products/fdd/configuration) > > Set up monitoring rules and assign notification policies to routines. > [card] [Events](/products/fdd/events) > > Monitor and investigate fault events with streaming and incident views. > [card] [Work order integration](/products/fdd/work-orders) > > Configure automatic work order generation from FDD events. # What is Fault Detection and Diagnostics? Source: https://docs.kodelabs.com/products/fdd/overview Understand how FDD uses events, incidents, and faults to monitor building equipment and detect operational issues in real time. FDD (Fault Detection and Diagnostics monitors equipment and detects operational issues in real time.) monitors building equipment in real time to detect operational faults, track events, and group related issues into incidents. The module organizes fault data across three levels so you can respond to immediate problems and analyze long-term patterns. Open FDD from the Cloud BMS portfolio or building sidebar. ## Core concepts A fault is a period of time in which a specified condition is true on a specific device. Each fault has a start time, an affected device, a condition, and a duration. ![Fault definition showing four components: Start Time at 8:00am, Device AHU-1, Condition could not maintain discharge temperature within setpoint, and Duration for 5 hours](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-definition.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c4df71c12274395be68d37e59423f26c) A fault combines a start time, device, condition, and duration into a single record FDD structures fault information into three levels: events, incidents, and faults. Each level serves a different purpose, from real-time response to long-term trend analysis. ### Events Events check multiple inputs across one or more devices. Each event carries an importance level and can serve as both an instantaneous indicator and a data point for analysis over time. Events alone can produce excessive output. Combine events with incidents and faults for actionable insight. ![Events page showing Pause Streaming, Last 7 Days date range, Filters, priority cards for Total 297, Life-Safety 0, Critical 2, Warning 66, and Alert 229, and a Table View of active events with Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, and Ack'ed columns](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f2464097b2f7a916f2bd137070d7718b) The Events list displays active fault events with filters, priority cards, and a sortable table Selecting an event opens the event report with automated device trend charts and a details sidebar for investigation. ![Event report for Discharge Fan Operation Failure showing a trend chart with Discharge Fan Status point, a red highlighted fault period, and a Details sidebar displaying Event State as Closed, Priority as Critical, Point Name, Point Value, Start Time, End Time, Duration of 9 minutes, Device FCU208, and Area Floor 2](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=5c0afc291616a8016b1de4510fe380ca) The event report shows device point trends with the fault period highlighted in red and a details sidebar | Example event | Description | | - | - | | Heating Not Active when Heating Required | The heating system is not running despite a heating demand signal | | Discharge Air Flow Lower than Expected | Measured airflow falls below the expected value for current conditions | | Simultaneous Heating and Cooling | Both heating and cooling systems are active at the same time | ### Incidents Incidents sit at the highest level. FDD creates incidents by finding commonalities between event groups using Reference Based Grouping (Groups related events by ontology relationships between equipment, such as an AHU and the VAVs it feeds.). This method looks along ontology (A standardized model of equipment types, points, and relationships used across Cloud BMS modules.) relationships to identify related equipment. For example, if a VAV (Variable Air Volume box — zone-level terminal unit that modulates airflow.) cannot meet its setpoint, FDD checks the upstream AHU (Air Handling Unit — primary airside equipment that conditions and supplies air to downstream terminals.) and sibling VAVs to determine whether the issue is isolated or systemic. Grouping related events under a single incident reduces the number of individual issues you need to investigate. ![Incident report for 260512-89642 with 36 VAVs showing Number of Events 85, Average Event Duration about 6 hours, Affected Areas 15, a Status gauge chart at 100% Closed, an Areas bar chart with Count and Avg Duration by floor, Domains pie chart showing Air Quality, Cooling Issue, and Heating Issue, Device Types pie chart, and a Details sidebar with Incident State Closed, Priority Alert, Start Time, End Time, Duration about 12 hours, and Building](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-incident-report-overview.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=115c033f912017c975189490f4ca5d0f) The incident report groups related events with summary metrics, area charts, and domain breakdowns The Overall Impact timeline shows which routines triggered events over the incident period. The table below lists all contributing events with their device, point data, duration, and priority. ![Incident report showing Overall Impact timeline with CO2 Near Max Setpoint, Damper Fully Open for Long Periods, and Flow Less Than Setpoint routines displayed as colored bars across the time axis, and a Table View listing events with columns for Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, Priority, Work Order URL, SLA, Area, and Ack'ed](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-incident-report-impact.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=646c58abf5c98e9d7bbb8789af5569cd) The Overall Impact timeline and events table show which routines and devices contributed to the incident > [!NOTE] > > Reference Based Grouping does not achieve a 100% catch rate. Some fault patterns may not group into incidents automatically. ### Faults Faults capture long-term or recurring issues across your equipment. Use faults to monitor trends, triage recurring problems, and prioritize maintenance over time. Faults are not designed for instant alerts or root-cause analysis. They complement events and incidents by providing a broader view of equipment health across days, weeks, or months. ![Fault report for Sensor Failure Out-of-Range Discharge Air Temperature showing a point trend chart for Discharge Air Temp over a two-week period with Combined, Lines, and Bars display options, and a Details sidebar displaying Description, Occurrences 1, Avg Duration 18 days, Daily Avg Occurrences 1, Last Comment, Last Activity, Last Work Order, Area Ground Floor, Device Report link, and Routine Report link](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-report.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=ad3c2c5af1e791cf5c1a632add859f0c) The fault report shows point trends over time with a details sidebar for tracking occurrences and duration ## Priority levels FDD assigns a priority level to each event, incident, and fault. The default configuration includes five levels: | Priority | Purpose | | - | - | | **Life Safety** | Conditions that pose an immediate safety risk | | **Critical** | Severe operational failures requiring urgent attention | | **Warning** | Conditions that may lead to equipment damage or discomfort | | **Alert** | Minor deviations from expected operation | | **Info** | Informational conditions for awareness only | Admins can customize priorities through the `Settings` page in the FDD module. You can configure between three and five priority levels with custom names, descriptions, colors, and SLA (Service Level Agreement settings that define response-time expectations for each priority.) settings to match your organization's triage workflow. ![FDD Settings page showing the Priorities tab with Acknowledgment, Table Management, and Triage Rules tabs, listing five priority levels: Life-Safety with description Immediate action required to prevent serious harm, Critical with description Urgent issue affecting comfort energy or mechanical systems, Warning with description Prompt attention needed for potential risk, Alert with description System irregularity detected, and Info with description Non-urgent notification, each with No SLA status, a colored badge, Edit button, and visibility toggle](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-settings-priorities.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5fa84f4f256ec4afcf95452dd1f128bf) The Priorities settings page lets you customize priority levels with names, descriptions, SLA rules, and visibility Quiz Fifteen VAVs on one floor miss setpoint in the same window. You want to know whether this is isolated terminals or a shared upstream AHU problem, without opening fifteen separate event investigations first. Where should you look? ## Next steps > [card] [Events](/products/fdd/events) > > Monitor and investigate real-time fault events across your building equipment. > [card] [Configuration](/products/fdd/configuration) > > Set up monitoring rules and thresholds for your equipment. > [card] [Dashboards](/products/fdd/dashboards) > > View building health at a glance with FDD dashboards. # KODE routine library Source: https://docs.kodelabs.com/products/fdd/routine-library Reference guide for pre-configured FDD routines covering airside, chilled water, and hot water system faults with tuning parameters. Cloud BMS includes a pre-configured library of FDD routines that cover common fault conditions across airside, chilled water, and hot water systems. These routines are ready to deploy and can be customized through parameter tuning. ## Routine structure Every library routine shares a common structure. Each routine includes a priority level, a fault domain, and a set of tuning parameters with default values. **Priority** assigns a severity level to each routine. The five levels are Life Safety, Critical, Warning, Alert, and Info. **Domain** groups routines by the type of fault they detect. Domains include Cooling Operation Failure, Heating Operation Failure, Air Quality, and AHU Fan / Pressure Issue. **Parameters** control the thresholds and delays that determine when a routine triggers an event. You adjust these values during configuration to match your equipment and site conditions. Common parameters across most routines include: | Parameter | Description | | - | - | | `Alarm On Delay` | Time a condition must persist before the routine generates an event | | `Start Delay` | Wait time after equipment starts before the routine begins monitoring | | `Return to Normal Delay` | Time a condition must clear before the routine closes the event | | Tolerance / threshold values | Deadbands and delta values that define acceptable operating ranges | ## Airside faults Airside routines monitor fan coil units, VAVs, and air handling units for cooling, heating, air quality, and fan or pressure faults. Parameters in each routine are color-coded by category: * Timing Delays that control when the routine generates or closes events * Threshold Equipment-specific thresholds, positions, and delta values * Deadband Setpoint deadbands, tolerances, and arbitrary setpoints ### Air quality > [accordion] CO2 near max setpoint > > Generates an event when CO2 concentration exceeds acceptable levels while the zone is occupied. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Air Quality | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | CO2 Max Arbitrary Threshold | 800 ppm | Threshold for CO2 breach notifications when no setpoint is configured | > | Relative Setpoint Deadband | 10% | Tolerated difference from the setpoint as a percentage for CO2 | > | Setpoint Deadband | 50 ppm | Tolerated difference from the setpoint for CO2 (use as a minimum value) | ### Cooling operation failure > [accordion] Cooling fully open for long periods > > Generates an event when the unit is commanded to maximum cooling for too long. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Cooling Valve Min Position | 5% | Minimum position to indicate near-full capacity operation | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > | Alarm Delay | 60 min | Delay after alarm conditions are met before generating the event | > [accordion] Cooling off in cooling mode > > Generates an event when zone temperature is high and cooling is not active. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Valve Min Position | 5% | Minimum position to indicate near-full capacity operation | > [accordion] Cooling off in cooling mode w/ discharge temperature > > Generates an event when zone temperature is high and cooling is not active. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Valve Min Position | 5% | Minimum position to indicate near-full capacity operation | > [accordion] Cooling stuck open > > Generates an event when zone temperature is high and cooling is not active. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (ZT SPT, ZT) - Delta | 1 delta F | Delta beyond which the operation should be off | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Damper operation failure in cooling mode > > Generates an event when the damper fails to open when cooling is required. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Discharge temperature greater than setpoint while occupied > > Generates an event when discharge temperature is too high while in cooling mode and occupied. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Power Min Threshold | 1 W or kW | Minimum threshold (watts/kilowatts) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Flow less than setpoint in cooling mode > > Generates an event when the damper fails to reach flow setpoint while in cooling mode. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Heating stuck open > > Generates an event when a heating source is detected while in cooling mode. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (ZT SPT, ZT) - Delta | 1 delta F | Delta beyond which the operation should be off | > | Heating Valve Min Position | 10% | Minimum actuator position in heating mode | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Insufficient cooling operation > > Generates an event when the unit is actively cooling but zone temperature does not drop sufficiently. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (DAT VAV, ZT) - Delta | 5 delta F | Delta between DAT VAV and zone temperature for sufficient cooling | > | (DAT VAV, DAT AHU) - Delta | 3 delta F | Delta between DAT VAV and DAT AHU for sufficient cooling | > | Cooling Valve Min Position | 90% | Minimum actuator position to check for insufficiency | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Insufficient cooling operation w/ discharge temperature and setpoint > > Generates an event when the unit is actively cooling but discharge temperature does not drop sufficiently. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (DAT VAV, ZT) - Delta | 5 delta F | Delta between DAT VAV and zone temperature for sufficient cooling | > | (DAT VAV, DAT AHU) - Delta | 3 delta F | Delta between DAT VAV and DAT AHU for sufficient cooling | > | Cooling Valve Min Position | 90% | Minimum actuator position to check for insufficiency | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Temperature greater than setpoint while occupied > > Generates an event when zone temperature is outside the acceptable range while in cooling mode and occupied. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Arbitrary Heating Setpoint | 66 F | Arbitrary setpoint below which notifications trigger when no setpoint exists | > | Arbitrary Cooling Setpoint | 75 F | Arbitrary setpoint above which notifications trigger when no setpoint exists | ### Heating operation failure > [accordion] Damper operation failure in heating mode > > Generates an event when the damper fails to open when heating is required. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Flow less than setpoint in heating mode > > Generates an event when the damper fails to reach flow setpoint while in heating mode. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Heating fully open for long periods > > Generates an event when the unit is outputting maximum heating for too long. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > | Alarm Delay | 60 min | Delay after alarm conditions are met before generating the event | > [accordion] Heating off in heating mode > > Generates an event when zone temperature is too low and heating is not active. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Heating Valve Min Position | 10% | Minimum actuator position in heating mode | > [accordion] Heating off in heating mode w/ discharge temperature > > Generates an event when discharge temperature is too low and heating is not active. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Heating Valve Min Position | 10% | Minimum actuator position in heating mode | > [accordion] Insufficient heating operation > > Generates an event when the unit is actively heating but zone temperature does not rise sufficiently. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (DAT VAV, ZT) - Delta | 5 delta F | Delta between DAT VAV and zone temperature for sufficient heating | > | Heating Valve Min Position | 90% | Minimum position to indicate near-full capacity operation | > | (DAT VAV, DAT AHU) - Delta | 3 delta F | Delta between DAT VAV and DAT AHU for sufficient heating | > [accordion] Insufficient heating operation w/ discharge temperature and setpoint > > Generates an event when the unit is actively heating but discharge temperature does not rise sufficiently. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | (DAT VAV, ZT) - Delta | 5 delta F | Delta between DAT VAV and zone temperature for sufficient heating | > | Heating Valve Min Position | 90% | Minimum position to indicate near-full capacity operation | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Temperature less than setpoint while occupied > > Generates an event when zone temperature is outside the acceptable range while in heating mode and occupied. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Heating Setpoint Deadband | 1.5 delta F | Tolerated difference from the heating setpoint | > | Cooling Setpoint Deadband | 1.5 delta F | Tolerated difference from the cooling setpoint | > | Single Setpoint Deadband | 3 delta F | Tolerated difference from a single setpoint | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Arbitrary Heating Setpoint | 66 F | Arbitrary setpoint below which notifications trigger when no setpoint exists | > | Arbitrary Cooling Setpoint | 75 F | Arbitrary setpoint above which notifications trigger when no setpoint exists | ### AHU fan and pressure issues > [accordion] Damper fully open for long periods > > Generates an event when the damper is at its maximum position for too long. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > | Alarm Delay | 60 min | Delay after alarm conditions are met before generating the event | > [accordion] Damper operation failure > > Generates an event when discharge airflow is less than setpoint and the damper exceeds its minimum position. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Discharge fan operation failure > > Generates an event when the discharge fan is not operating as commanded (feedback does not match command). > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Max Threshold | 2% | Maximum threshold (%) for a fan off status | > | Fan Current Max Threshold | 0.1 Amp | Maximum threshold (Amps) for a fan off status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > [accordion] Duct pressure less than setpoint while fan near maximum > > Generates an event when the fan runs at its upper limit and does not meet the discharge pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Relative Pressure Tolerance | 20% | Tolerated pressure deviation from setpoint as a percentage | > | Nominal Pressure Tolerance | 0.1 psi | Tolerated pressure deviation from setpoint (use a low number) | > | Fan Min Position | 95% | Minimum fan position (%) when experiencing pressure issues | > [accordion] Fan operation failure while duct pressure less than setpoint > > Generates an event when the fan runs at its lower limit and does not meet the discharge pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Nominal Pressure Tolerance | 0.1 psi | Tolerated pressure deviation from setpoint (use a low number) | > | Relative Pressure Tolerance | 20% | Tolerated pressure deviation from setpoint as a percentage | > | Fan Min Position | 95% | Minimum fan position (%) when experiencing pressure issues | > [accordion] Fan/pump operation failure > > Generates an event when the unit is not operating as commanded (feedback does not match command). > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > | Fan Max Threshold | 2% | Maximum threshold (%) for a fan off status | > | Fan Current Max Threshold | 0.1 Amp | Maximum threshold (Amps) for a fan off status | > [accordion] Flow less than setpoint > > Generates an event when discharge airflow is less than setpoint and the damper is at or below minimum position. > > | Property | Value | > | - | - | > | **Priority** | Alert | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Relative Flow Tolerance | 10% | Tolerated flow deviation from setpoint as a percentage | > | Nominal Flow Tolerance | 20 cfm | Tolerated flow deviation from setpoint (use a low number) | > | Damper Min Position | 95% | Minimum damper position to indicate a starved box | > [accordion] Return fan operation failure > > Generates an event when the return fan is not operating as commanded (feedback does not match command). > > | Property | Value | > | - | - | > | **Priority** | Warning | > | **Domain** | AHU Fan / Pressure Issue | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Fan Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a fan on status | > | Fan Max Threshold | 2% | Maximum threshold (%) for a fan off status | > | Fan Current Max Threshold | 0.1 Amp | Maximum threshold (Amps) for a fan off status | > | Fan Min Threshold | 5% | Minimum threshold (%) for a fan on status | ## Chilled water system faults Chilled water routines monitor pumps, differential pressure, and supply temperatures across chilled water and condenser water loops. > [accordion] Chilled water diff pressure less than setpoint > > Generates an event when chilled water pumps cannot meet the differential pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Chilled water temp greater than setpoint > > Generates an event when the chilled water system fails to cool water to its required temperature. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Temp - Delta | 2 delta F | Tolerated delta from the setpoint | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > [accordion] Chilled/condenser water loop diff pressure less than setpoint > > Generates an event when cooling water pumps cannot meet the loop differential pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Chilled/condenser water loop temp greater than setpoint > > Generates an event when the system fails to cool the water loop to its required temperature. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Condenser water diff press less than setpoint > > Generates an event when condenser water pumps cannot meet the differential pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Condenser water temp greater than setpoint > > Generates an event when the system fails to sufficiently cool the condenser water. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Cooling Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Temp - Delta | 2 delta F | Tolerated delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | ## Hot water system faults Hot water routines monitor pumps, differential pressure, and supply temperatures across hot water loops. > [accordion] Hot water diff pressure less than setpoint > > Generates an event when hot water pumps cannot meet the differential pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Hot water loop diff pressure less than setpoint > > Generates an event when hot water loop pumps cannot meet the differential pressure setpoint. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Diff Press - Delta | 2 delta F | Tolerated delta from the setpoint | > | Relative Water Diff Press - Delta | 20% | Tolerated relative (%) delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Hot water loop temp less than setpoint > > Generates an event when the system fails to heat loop water to its required temperature. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Temp - Delta | 2 delta F | Tolerated delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | > [accordion] Hot water temp less than setpoint > > Generates an event when the hot water system fails to heat water to its required temperature. > > | Property | Value | > | - | - | > | **Priority** | Critical | > | **Domain** | Heating Operation Failure | > > | Parameter | Default | Description | > | - | - | - | > | Start Delay | 30 min | Delay after equipment starts before checking for alarm conditions | > | Alarm On Delay | 15 min | Delay after alarm conditions are met before generating the event | > | Return to Normal Delay | 5 min | Delay after alarm conditions clear before closing the event | > | Water Temp - Delta | 2 delta F | Tolerated delta from the setpoint | > | Pump Min Threshold | 5% | Minimum threshold (%) for a pump on status | > | Pump Current Min Threshold | 1 Amp | Minimum threshold (Amps) for a pump on status | ## Next steps > [card] [FDD configuration](/products/fdd/configuration) > > Configure routines, set thresholds, and assign priorities for your site. > [card] [Routines](/products/fdd/routines) > > Create, test, import, and export FDD routines. # Routine logic blocks Source: https://docs.kodelabs.com/products/fdd/routine-logic-blocks Reference guide for all logic block types available in the FDD routine builder, organized by palette category. Logic blocks are the building components of FDD routines. Each block performs a specific operation, and you connect them to create the logic for fault conditions. The Logic palette groups blocks into these categories: Read, Parameters, Organize, Constants, Arithmetical, Arrays, Conditional, Switches, Logical, Comparison, Timing, Buffering, Schedule, and Alarming. ## Read blocks Read blocks bring point data into your FDD routine. Each Read block has three inputs (Name, Main/Secondary, Field) and two outputs (Status, Value). ### Configuration fields **Field** `Field` Click inside the `Field` input box to open a selection dialog. Available points are scoped based on the entities defined in the routine. If you do not see a required point, verify that the routine's entities include the field you need. ![Select Field dialog in the Logic tab showing a Base dropdown expanded with Required Fields listing occupied mode and run status as selectable options, with Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-select-field.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9f091ec30310f79dac03934dd28cd8f2) The Select Field dialog shows required fields scoped by the entities defined in the routine **Name** `Field` A free-form input where you assign a label to the block. Use a name that matches or closely resembles the point name for easy reference during debugging and reporting. **Main / Secondary** `Toggle` Designate whether the point is the main reference point or a supporting point. Every routine must have exactly one main Read block (set to `Main`). When an event is generated, the system uses the main point as the reference to other modules in Cloud BMS. All other Read blocks are supporting points (`Secondary`). ### Point types Each Read block type outputs a different data type. #### String Point Outputs the current string reading from the selected point. ![String Point block with Name, Main or Secondary, and Field inputs, and Status and Value outputs](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/fdd/kode-os-fdd-block-string-point.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=212573eeec5e4e6ca5384e3e6b251c43) #### Number Point Outputs the current number values from the selected point. ![Number Point block with Name, Main or Secondary, and Field inputs, and Status and Value outputs](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/fdd/kode-os-fdd-block-number-point.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=d9f779967557fd9e885bc3696eca3b47) #### Boolean Point Outputs the current boolean values from the selected point. ![Boolean Point block with Name, Main or Secondary, and Field inputs, and Status and Value outputs](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/fdd/kode-os-fdd-block-boolean-point.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=c7910745e546ec9c54183c246f71a140) #### Enum Point Outputs the current enum-mapped values from the selected point. The Field input is derived from device entities and enum mapping. ![Enum Point block with Name, Main or Secondary, and Field inputs, and Status and enum value outputs](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/fdd/kode-os-fdd-block-enum-point.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=9398286f00d18961b23bbfff10f447e4) ### Read arrays Within a device, it is possible to have two distinct fields that share the same name. In these cases, the field is appended with an identifying number, and the status of that field is an aggregate of the numbered variants. FDD identifies the array potential of these fields and allows you to select an array Read block. For example, if a device has two compressor stages, determining whether the compressor is running requires checking both stage points. With a Read Array block, you bring in a single block instead of separate Read blocks for each stage. This simplifies the routine logic and covers all variations of multi-stage equipment within a single routine. Array blocks have Name and Field inputs and output lists where each item represents a point in the array. #### String Array Outputs a list of string values from points in the array. ![String Array block with Name and Field inputs, and Status and Value list outputs](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-string-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=6697d12d502b571d4f08724f71dea431) #### Number Array Outputs a list of number values from points in the array. ![Number Array block with Name and Field inputs, and Status and Value list outputs](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-number-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=cd08da2ecc7af3e70ee3ce2ae36a014a) #### Boolean Array Outputs a list of boolean values from points in the array. ![Boolean Array block with Name and Field inputs, and Status and Value list outputs](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-boolean-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=faeb8229a29999e67d515cca85a11c8e) #### Enum Array Outputs a list of enum values from points in the array. ![Enum Array block with Name and Field inputs, and Status and Value list outputs](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-enum-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=7faa417520ba38b0de88298db792506c) ## Parameter blocks Parameter blocks let you define adjustable values that can be customized per project without modifying the routine logic. Values set in parameter blocks become available when [configuring a routine](/products/fdd/configuration) on the `Configs` page. Each parameter block has three inputs (Name, Hint, Value) and one Output. **Name** `Field` A human-readable label for the parameter. Use a descriptive name that can be understood by anyone reviewing the routine. Clear naming minimizes confusion when troubleshooting or understanding the parameter's intent later. **Hint** `Field` A string input that appears when hovering over the information icon during configuration. Use as many words as necessary to communicate the parameter's intent, expected range, and purpose. ![Parameter hint tooltip showing Pressure Min Threshold value 0.40 with info icon expanded to display the hint text: How much should the duct pressure be minimally](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-param-hint.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=cd3b75a9689a3574f27ee12e3d107717) The Hint text appears as a tooltip when hovering over the info icon during configuration **Value** `Field` The default value for the parameter. When you configure the routine on the `Configs` page, you alter this input to the algorithm. Most parameters require a default value. ### Parameter types #### Number Outputs the number specified in the value field. Values are available for customization during configuration. ![Number parameter block with Name, Hint, and Value inputs showing default 0, and Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-number-param.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=4bffbf612f3f13efc5a8da301f6ba4a0) #### Boolean Outputs the boolean specified in the value field. Values are available for customization during configuration. ![Boolean parameter block with Name, Hint, and Value inputs showing default False, and Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-boolean-param.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=a4001fa5bf10636f2675af10ec54f7f1) #### String Outputs the string specified in the value field. Values are available for customization during configuration. ![String parameter block with Name, Hint, and Value inputs, and Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-string-param.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=a403726efe53ed336017cfdc0fe4aa46) ## Organize blocks Organize blocks help you structure complex routines on the canvas. ### Folder Folds a group of blocks into a single block on the main canvas. Use a folder to hide detail and reuse the same sub-logic across routines. On the main canvas, the folder shows its name and the inputs and outputs you define inside it. In this example, a folder named `Parameters` exposes `Alarm On Delay` and `Return to Normal Delay` outputs. ![Folder block named Parameters with Alarm On Delay and Return to Normal Delay outputs](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-folder.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=1e9f328077ccb581137771bc29c2012e) Open a folder to inspect or edit the blocks inside before you reuse it. Folder internals are not visible on the main canvas. #### Folder IO blocks Folder IO blocks appear only inside a folder. They define how values pass into and out of the folder. ##### Input Defines one value that enters the folder from the main canvas. Give the input a name and select its data type. The type list includes `Number`, `String`, `Boolean`, `Number Array`, `String Array`, and `Boolean Array`. Wire the value into your folder logic from the block `Output`. ![Folder Input block with name Input 1, type dropdown open showing Number, String, Boolean, Number Array, String Array, and Boolean Array, and an Output port](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-folder-input.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=ce366a0ec82252d76d1d1b69f13775b2) ##### Output Defines one value that leaves the folder to the main canvas. It works in reverse of an Input block. Give the output a name and select its data type. Wire your folder logic into the block `Input`. ![Folder Output block with name Output 3, Number type dropdown, and an Input port](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-folder-output.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=cb2798ccc46756e19fb8085df77fe282) On the main canvas, each Input and Output block appears as a named port on the folder. ## Constants blocks Constants blocks supply fixed values and mapped labels for use in comparisons and switches. ### Result Accepts a value through its single `Input`. The block has no output and no fields to configure. ![Result block with a single Input port and no output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-result.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=09259e59d101e3de6d1575ad0d05cedb) ### Status Provides one output for each system status value. Wire the output that matches the status you want to use in your logic. Outputs are `ok`, `alarm`, `unacked alarm`, `overridden`, `stale`, `disabled`, `down`, `fault`, `connector down`, `invalid response`, `unknown`, and `no value`. ![Status block with one output for each system status value, including ok, alarm, stale, disabled, down, fault, unknown, and no value](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-status.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=9ba2fd85b446e8f297cc691129b7c388) ### String Builder Returns a concatenation of all string inputs. Use this block to join multiple string values into one output. **Word Inputs** `Field` Enter or wire a string value into each word slot, such as `1st Word` and `2nd Word`. Select `+` in the block header to add more slots. Select `-` on a slot to remove it. The `Output` returns the combined string. ![String Builder block with 1st Word and 2nd Word inputs, add and remove controls, and an Output port](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-string-builder.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=ce2a7d65a4cd3fb04637d96ad3db5277) ### Enum Builder Lets you select a particular output of an enum. Use this block to work with one enum value at a time, such as `On`, `Off`, or `Unknown`. **Field** `Field` Select `Field` to open the Select Field dialog. Choose the point whose enum you want to extract, then select `Save`. ![Select Field dialog for Enum Builder showing Hot Water System expanded with a required field listed, and Cancel and Save buttons](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-enum-builder-select-field.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=1ce355c27ff0b8035087a8fc337d63a1) The Select Field dialog for Enum Builder, showing a device with its required fields After you select a field, the block shows one output for each enum value of that field. Wire the output for the value you need. ![Enum Builder block with a Field input and a single enum output on the left, and an example on the right showing On, Off, and Unknown outputs for a selected field](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-enum-builder.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=53e85d8e564c940805497b2dd0fb6e9c) ## Arithmetical blocks Arithmetical blocks perform mathematical operations on number inputs. Use these blocks to calculate differences, ratios, and derived values from your point data. Arithmetical blocks come in two forms: **Single-input blocks** accept one number input (or a static value) and produce one result. ![Absolute block with one number input, a static value field, and Result output](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-block-absolute.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=89d81db06ee2488c07db0b5e2fd83df6) Absolute block: outputs the absolute value of the input **Multi-input blocks** accept two or more number inputs (or static values) and produce one result. Select the `+` button to add additional input fields. ### Available operations #### Absolute Outputs the absolute value of the input value. ![Absolute block with one number input, a static value field, and Result output](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-block-absolute.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=89d81db06ee2488c07db0b5e2fd83df6) #### Sum Outputs the post-calculated value from adding all inputs. ![Sum block with two number inputs, Add Operands button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-sum.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=587927613b5a3710d3ad015f5cae6c00) #### Difference Outputs the post-calculated value from subtracting inputs. ![Difference block with two number inputs, Add Operands button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-difference.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=da6843607ad2263501593f5df988d151) #### Product Outputs the post-calculated value from multiplying inputs. ![Product block with two number inputs, Add Operands button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-product.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=6c17de46e7e2db8bbab4d404877ac88c) #### Quotient Outputs the post-calculated value from dividing inputs. ![Quotient block with two number inputs, Add Operands button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-quotient.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=1ce00fa1d61c83fb2211718e783632d5) #### Mean Outputs the average of input values. ![Mean block with two number inputs, Add Inputs button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-mean.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=83d41e451ac235a316349622efe4ae28) #### Max Outputs the largest input value. ![Max block with two number inputs, Add Inputs button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-max.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f90679e7aa681c7c3ed0a0fa06e209b1) #### Min Outputs the smallest input value. ![Min block with two number inputs, Add Inputs button, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-min.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=a3d310fb2b934e944ceace89f2419b41) #### Round Rounds a number and outputs the result. The block takes two number inputs. ![Round block with two number inputs and an Output port](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-round.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=0b2c13efa4d5c176fb13b2400d498f27) #### Modulo Outputs the remainder from calculating the quotient of the inputs. ![Modulo block with two number inputs and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-modulo.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=e8278241556da3643740f9fd37ac3b4d) #### Power Raises a number to a power and outputs the result. The block takes two number inputs. ![Power block with two number inputs and a Result output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-power.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=475c91333c52dabecf5a5b7c494ddf9c) #### Square Root Outputs the square root of a number input. ![Square Root block with one number input and a Result output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-square-root.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=cd5a6143525b735ad5b51f595fd69e41) ## Arrays blocks Arrays blocks process a series of data points collected from the same source over time. Use these blocks to analyze trends, find patterns, and compute statistics. Each block accepts a list input and returns a single result. In the Logic palette, these blocks appear under `Arrays` with short names such as Max, Mean, Min, Sort, and Sum. ### Available operations #### Delta Returns the difference between the minimum value and the maximum value in the list. ![Delta block with list input and Result output showing the difference between min and max values](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-delta.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=7371a812f175a205c47c7f449878ca8b) #### Length Returns the count of items in the provided list. Accepts lists of numbers, booleans, or strings. ![Length block with list input and Result output showing the count of items](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-length.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=d46b67be938b97f69602d8e5b0c6227f) #### Max Array Returns the largest number in the list. ![Max Array block with list input and Result output showing the largest value](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-max-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c0d3e570af9c8e49591815f6cac87882) #### Mean Array Returns the mean of the numbers in the list. Select between `Weighted` or `Simple` calculation mode. ![Mean Array block with Weighted or Simple selector, list input, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-mean-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=2f43935833a2ee9d2dea4431026d35b6) #### Min Array Returns the smallest number in the list. ![Min Array block with list input and Result output showing the smallest value](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-min-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=41eca5877b883b377361961360378cbc) #### Sort Array Returns the input list sorted in the specified order. Select between `Ascending` or `Descending`. ![Sort Array block with Ascending or Descending selector, list input, and sorted list Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-sort-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f38be5faff189de2b9200bf9bcb96dd6) #### Std Deviation Returns the standard deviation of the numbers in the list. Select between `Weighted` or `Simple` calculation mode. ![Std Deviation block with Weighted or Simple selector, list input, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-std-deviation.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=5f47d9bf5ce8d2b8588ba4566eb698da) #### Sum Array Returns the sum of all the numbers in the list. ![Sum Array block with list input and Result output showing the sum of all values](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-sum-array.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=7cabbe0353b51c6a1ae4724917a91695) #### Variance Returns the variance of the numbers in the list. Select between `Weighted` or `Simple` calculation mode. ![Variance block with Weighted or Simple selector, list input, and Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-variance.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c37d457e41922b4c82bfa2efa3268339) ### Example workflows **Difference between highest and lowest values over five minutes:** Read Number > Buffer Time (5 min) > Array Sort (Ascending) > Array Delta This workflow captures five minutes of data, sorts the values, and calculates the difference between the highest and lowest readings. **15-minute rolling average:** Read Number > Buffer Time (15 min) > Array Mean This workflow buffers 15 minutes of readings and outputs the running average. ## Conditional blocks Conditional blocks direct the routine's execution path based on input data. ### If The If block evaluates a boolean input and routes to one of two outputs. The `Do` output fires when the condition is true, and the `Else` output fires when the condition is false. ![If block with boolean input, Do output for true condition, and Else output for false condition](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-if.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=761cdfbd928ef2b3539e61d2f41cfa67) ## Switch blocks Switch blocks evaluate a conditional input and output the corresponding value based on whether the condition is true or false. Each switch type outputs a different data type. In the Logic palette, these blocks appear under `Switches`. ### Numeric Switch Outputs the corresponding number associated to the evaluated true or false condition. ![Numeric Switch block with conditional input, two return value inputs with static value fields, and number Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-numeric-switch.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=397fb64604ae5285d41badd3042f15be) ### Boolean Switch Outputs the boolean associated to the evaluated true or false condition. ![Boolean Switch block with conditional input, True and False return values, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-boolean-switch.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=ed3e7414a0172b97ef1fea97bfea8e5f) ### String Switch Outputs the corresponding string associated to the evaluated true or false condition. ![String Switch block with conditional input, two return value inputs with static value fields, and string Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-string-switch.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=0371616f04c8fca729255b3f321787eb) ## Logical blocks Logical blocks perform boolean operations on inputs. Select the `+` button on multi-input blocks to add additional conditionals. ### Or Outputs true if any input value is true. ![Or block with two boolean inputs, Add Operands button, static value fields, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-or.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=7118cd76f965d74bd3c8d81d01f8963b) ### Not Returns the opposite boolean from the input. ![Not block with one boolean input and inverted boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-not.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=d25d1c4247d11890cb590e9e259de15c) ### And Outputs true if all input values are true. ![And block with two boolean inputs, Add Operands button, static value fields, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-and.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=699da45aef706e38969799ae2aaeafd0) ### Merge Sends data from any of its inputs to the output as observations are received, regardless of order. Inputs must be of the same data type. Select `+` to add additional inputs. ![Merge block with 1st Input and 2nd Input, Add Inputs button, and output matching the input type](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-merge.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=e354b9d33c544a65686b484937bd43d2) ## Comparison blocks Comparison blocks evaluate values against each other or against list membership. Combine these blocks to build complex conditions that evaluate multiple fault criteria at the same time. ### Greater Than Outputs true if the left operand is greater than the right. Accepts number inputs or static values. ![Greater Than block with two number inputs, static value fields, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-greater-than.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=bcfbab67bd74268cf58016d83b73d7c0) ### Less Than Outputs true if the left operand is less than the right. Accepts number inputs or static values. ![Less Than block with two number inputs, static value fields, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-less-than.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=67172f62d86975cd41792fe6d33e134d) ### Equals Outputs true if both inputs are evaluated as equal. Accepts number, boolean, or string operands of the same type. ![Equals block with Left Operand and Right Operand inputs and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-equals.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=ec765fff91fcf2300501a6e59b28ee85) ### In Outputs true if the data observation received by the Value input is found as an item in the input list. Accepts lists of numbers, booleans, or strings. ![In block with list Input, Value input, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-in.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=42423582f16bd87051fa5d25b3b03b42) ### All Outputs true if all items in the input list match the provided value. Accepts lists of numbers, booleans, or strings. ![All block with list Input, Value input, and boolean Result output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-all.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=144ff52acab0cd4029f0f1b9e9c29ec4) ## Timing blocks Timing blocks introduce delays into routine logic. Each timing block accepts a time unit (seconds, minutes, or hours) and a count value. You can set the count as a static number or link it from another block's output. ### Debounce Waits for the specified amount of time and outputs a value only if that value has been unchanged during that period. ![Debounce block with time unit selector, count input with static value, data Input, and typed Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-debounce.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=d75978cfab1bdf116bef810fbd7342a9) ### Audit Waits for the specified amount of time and outputs the last value received from the input. ![Audit block with time unit selector, count input with static value, data Input, and typed Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-audit.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=26f001252b995e4525e89b906737b94c) ## Buffering blocks Buffering blocks collect data over a specified time window or count for use with Arrays blocks. ### Buffer Time Collects values from the input into a list that is returned after the specified amount of time. ![Buffer Time block with time unit selector, count input with static value, data Input, and list Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-buffer-time.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=080f9de63cd41d01d7276d84f7904b86) ### Buffer Count Collects values from the input into a list that is returned when the count is satisfied. ![Buffer Count block with count input with static value, data Input, and list Output](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-buffer-count.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=908da9d5fee83acdc1b679ee9e2eee69) ## Schedule blocks Schedule blocks evaluate the current day and time against a configured weekly schedule. ### Time Window Outputs true when the current day and time fall within the configured weekly schedule. Use this block to limit evaluation to occupied hours, maintenance windows, or other recurring periods. ![Time Window block with Name and Schedule inputs and boolean Result output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-time-window.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=2d50703b7a96e4d90b023aa880b5583f) **Name** `Field` A free-form label for the block. Use a name that makes the schedule purpose clear during debugging and reporting. **Schedule** `Field` Select `Schedule` to open the schedule configuration dialog. Choose the days of the week and the hours when the block should return true. Selected days appear as filled circles. For each selected day, set a start time and end time. Use `+` on a day row to add another time range for that day. Use `Copy to all` to apply one day's times to every other selected day. Select `Save` to apply the schedule, or `Cancel` to discard changes. ![Schedule dialog with day-of-week buttons S through S, Monday through Friday selected, each day showing start time 09:00 and end time 17:00 with plus and Copy to all controls, and Cancel and Save buttons](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-time-window-schedule.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=b56d8f3145622725ae8f056116b2a978) The Schedule dialog sets days of the week and daily time ranges for the Time Window block The `Result` output returns true when the current time matches any configured range for the current day. Outside those ranges, the output is false. ## Alarming blocks Alarming blocks generate events and check device or connector health. ### Alarm Trigger Every FDD routine must include and end with an Alarm Trigger block. When the Alarm Trigger receives a true boolean input, the system generates an event. ![Alarm Trigger block with boolean input that generates an event when it receives a true value](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-block-alarm-trigger.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f3a9d3cfd1e2a080bd0e43f0ea44acdf) > [!WARNING] > > A routine without an Alarm Trigger block cannot generate events. Verify that your logic path connects to an Alarm Trigger before saving. ### Device Status Outputs the status of a device you select. Use it to gate alarms on device health. ![Device Status block with Main or Secondary dropdown set to Secondary, a Device field, and a Status output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-device-status.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=41e0411a3369a5c8a197c6f898464bde) **Main / Secondary** `Toggle` Designate whether the device is the main reference or a supporting device. Every routine must have exactly one main point. **Device** `Field` Select `Device` to open the Select Device dialog. Choose the device whose status you want to see, then select `Save`. ![Select Device dialog with Hot Water System listed as a selectable device, and Cancel and Save buttons](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-select-device.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=13b2dd3305d83c95365679aaee8b7ea6) The Select Device dialog lists the devices available to the routine The `Status` output carries the current status of the selected device. ### Connector Status Outputs the connector status for a device you select. Use it to gate alarms on data source health. ![Connector Status block with Main or Secondary dropdown set to Secondary, a Device field, and a Status output](https://mintcdn.com/kodelabs/-Zi5KcXD1Mk52Skg/images/kode-os/fdd/kode-os-fdd-block-connector-status.png?fit=max\&auto=format\&n=-Zi5KcXD1Mk52Skg\&q=85\&s=c5b6f562cdf95dc773480b28ce330e58) **Main / Secondary** `Toggle` Designate whether the device is the main reference or a supporting device. Every routine must have exactly one main point. **Device** `Field` Select `Device` to open the Select Device dialog. Choose the device whose connector status you want to see, then select `Save`. The `Status` output carries the current connector status of the selected device. ## Next steps > [card] [Routines](/products/fdd/routines) > > Create, test, and manage routines using the logic builder and debugger. > [card] [FDD configuration](/products/fdd/configuration) > > Apply routines to your devices and configure monitoring parameters. # Routines Source: https://docs.kodelabs.com/products/fdd/routines Create, test, import, export, and manage FDD routines using the logic builder and debugger to define custom fault rules for your equipment. FDD routines define the logical rules that monitor your building equipment for specific fault conditions. Cloud BMS provides a pre-configured library of routines and a logic builder for creating custom rules. > [!NOTE] > > Navigate to `FDD` from the left sidebar, then select `Routines` from the secondary sidebar. ## Routines list The Routines list displays routines built in your client environment. Use the search bar and `Filters` button to find specific routines. > [!NOTE] > > Global routines from the FDD library are not available on this page. Access library routines through [FDD configuration](/products/fdd/configuration). ![Routines page showing the FDD secondary sidebar with Events, Faults, Routines, Policies, configuration, and Settings, a search bar, Filters button, Create Routine button, Export and Import buttons, and a table listing routines like Heating Fully Open for Long Periods FCUs CV6-Way and Cooling Fully Open for Long Periods with columns for Name, Description, Domain, Priority, Grouping Policy, and Recommended Type, showing 507 routines across 11 pages](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-list-full.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=67fa3d79c7ef62b277654a2e1c6d8d0d) The Routines page lists all routines with search, filters, and action buttons for creating, exporting, and importing | Column | Description | | - | - | | `Name` | Routine name | | `Description` | Summary of the fault condition the routine detects | | `Domain` | Equipment domain the routine applies to | | `Priority` | Default priority level for generated events | | `Grouping Policy` | How related events are consolidated | ### Row actions Select the three-dot menu on any routine row to access available actions: * **Edit Routine**: Open the routine in the logic builder * **Export Routine**: Download the routine as a file for sharing or backup * **Duplicate Routine**: Create a copy of the routine with a new name * **Delete Routine**: Permanently remove the routine ![Routines page with a search filtered to temperature gr showing Temperature Greater Than Set Point While Occupied routine with domain Cooling Operation Failure, priority Alert, grouping policy None, and an open three-dot menu displaying Edit Routine, Export Routine, Duplicate Routine, and Delete Routine options](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-row-actions.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5c95cd0c98042e70956b1e8dfe2cd482) The three-dot menu on each routine row provides Edit, Export, Duplicate, and Delete actions ## Create a routine **1. Set routine details** Select `+ Create Routine` from the toolbar. The `Workflow Details` tab opens. ![Workflow Details tab for Heating Fully Open for Long Periods FCUs CV6-Way showing Name field, Description field with detailed routine logic explanation, Recommended Type set to Event, Domains set to Heating Issue, Events Grouping set to Reference Based, Priority set to Alert, a Base device group with Add Devices button, and an Add 1st Solution button, with Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-workflow-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=c00c5d75924a8c57f63dff5e7ddf4baf) The Workflow Details tab contains the routine name, description, recommended type, domains, grouping, priority, and device configuration Complete the following fields: | Field | Description | | - | - | | `Name` | A descriptive name for the fault condition | | `Description` | Explanation of what the routine detects | | `Domains` | Equipment domains this routine applies to | | `Events Grouping` | How events from this routine are grouped | | `Priority` | Default priority level for generated events | | `Canonical Types` | Equipment types for base and reference devices | | `Entities` | Entity definitions for base and reference devices | When you select entities in **Add Devices**, the first click includes the entity as a required field. A second click marks the entity in red. A red (excluded) entity means the routine looks for devices that have the other required entities and do **not** contain that excluded entity. Use exclusion when you need to filter out devices that carry an unwanted field. ![Add Devices dialog with Name As set to Base, a Canonicals section showing selectable tags for fcu, vav, ahu, fan, radiant device, and uh with a search field, and an Entities section showing selectable tags for OM, ZTS, ZTSS, CLGUM, COUNTER, CSM, DAF, DFC, DFCS, DFEN, DFFREQ, DFM, DFMODE, DFRPC, DFRPS, DFS, DFSS, DFSTAGE, DFSTATS, DSM, DTS and more with a search field, Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-add-devices.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b3d5efab3bf591b83fbab980d599af0a) The Add Devices dialog lets you select Canonicals and Entities for base and reference devices **2. Build the logic** Open the `Logic` tab. The left panel contains available logic blocks organized by category: Read, Parameters, Organize, Constants, Arithmetical, Arrays, Conditional, Switches, Logical, Comparison, Timing, Buffering, Schedule, and Alarming. Drag blocks from the left panel onto the canvas to build the routine logic. Connect blocks in sequence to create the logical path from data input to alarm output. Each routine must start with at least one Read block and end with an Alarm Trigger block. ![Logic tab for Heating Fully Open for Long Periods FCUs CV6-Way showing the left panel with block categories including Read, Parameters, Organize, and Constants, and a visual canvas with connected blocks: Enum Point for Discharge Fan Status, Enum Builder with On Off Unknown values, Number Point for CV6 with primary loop valve position, Parameters block with Start Delay, Alarm On Delay, Return to Normal Delay, and Heating Valve Command, a Delayed Check block, Less Than Equal comparison, And logic gate, and a Delayed Alarm Trigger ending in an Alarm Trigger block](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routine-logic-builder.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=1f75dfb4e8d4a7d9962fc68b6c81eef4) The Logic tab provides a visual canvas for connecting blocks into a logic sequence > [!NOTE] > > See [Routine logic blocks](/products/fdd/routine-logic-blocks) for a complete reference of available block types and their functions. **3. Test with the debugger** Open the `Debugger` tab. The left sidebar displays `PARAMS` (adjustable parameter values) and `INPUTS` (simulated device data). The main screen shows the Simulator output. ![Debugger tab for Heating Fully Open for Long Periods FCUs CV6-Way showing PARAMS section with Start Delay 30, Alarm On Delay 60, Return to Normal Delay 15, and Heating Valve Command -90, INPUTS section with CV6 value field and Status ok, Discharge Fan Status with Select Value dropdown and Status ok, a Send button, and the main Simulator area displaying a Start Simulation button with Stop and Restart controls](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-debugger-start.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=fb70b55f5726369d8ea8e41381aafa4f) The Debugger tab shows parameters and inputs on the left, with the Start Simulation button in the center 1. Review the `PARAMS` section and adjust parameter values as needed. 2. Select `Start Simulation` to begin the test. 3. Update `INPUT` values to simulate different conditions, then select `Send`. ![Debugger tab with PARAMS showing Start Delay 30, Alarm On Delay 60, Return to Normal Delay 15, and Heating Valve Command -90, INPUTS showing CV6 value 50, Status ok, Discharge Fan Status set to On, Status ok, and the Simulator showing Starting status with Action Heating Fully Open for Long Periods FCUs CV6-Way logged at 10:09 AM](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-debugger-send.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=25f812499df33ad763fa8bba1dcf1fc9) After sending input values, the Simulator logs actions with timestamps 4. Verify that the routine produces the expected response for each scenario. > [!TIP] > > Delay times run in real time during simulation. To speed up testing, temporarily change time units to seconds on timer logic blocks. Return to the correct units before deploying. > [!TIP] > > Test boundary values thoroughly. Verify conditions that should trigger events and conditions that should not. This catches threshold errors before deployment. **4. Save the routine** Select `Save`. The routine appears in the Routines list and becomes available for configuration on the `Configs` page. ## Export and import routines Transfer routines between environments as `.json` files. Export downloads proven rules. Import uploads them without rebuilding logic. > [tab] Export > > The export feature lets you download routines as files for sharing or transferring to other environments. > > **1. Select routines to export** > > Select the checkboxes next to the routines you want to export. The `Export` button at the bottom right shows the count of selected routines. > > ![Routines page with two routines selected via checkboxes, with Cancel and Export buttons at the bottom showing a count of 2 selected](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-export-select.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4fb40dfda8c191fecf3c636fbfdec727) > > Select routines from the list using checkboxes, then select Export > > **2. Name the export file** > > Enter a name for the export file in the `File Name` dialog and select `Save`. > > ![File Name dialog with a Name field and Cancel and Save buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-export-name.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=25cd049164695ebd759bdfc82f8abf6f) > > Assign a name to the export file > > **3. Download the file** > > The file downloads to your computer as a `.json` file. > > ![Browser download bar showing exported JSON file](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-export-download.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=c44e3fd81a20304e7f4913092747b795) > > The exported routines download as a JSON file > [tab] Import > > The import feature lets you upload routines from exported files to add proven rules without rebuilding them. > > **1. Open the import dialog** > > Select `Import` at the top right of the Routines page. The Import Routines dialog opens with a file upload area. > > ![Import Routines dialog with a dashed border upload area](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-import-upload.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5eff61a2372d68ec63653ae80b67274d) > > The Import Routines dialog accepts a file upload or drag and drop > > **2. Upload and review routines** > > Select a file from your computer or drag and drop it into the upload area. The dialog displays the imported routines with editable fields for name, description, priority, and grouping policy. > > In the `Replace` column, choose how to handle conflicts with existing routines: > > * **Replace** overwrites the existing routine with the imported version > * **Keep both** retains the existing routine and adds the imported version > * **Keep old** ignores the imported routine and retains the existing version > > ![Import Routines review page with editable routine fields and conflict resolution options](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-routines-import-review.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9f03ccfb25d3a64a9cd0cd8fe1545203) > > Review imported routines, edit details, and choose how to handle conflicts > > **3. Complete the import** > > Select `Import` to finalize. The imported routines appear in your routines list. Select `Discard` to cancel without importing. ## Data and permissions Routines are the intellectual property of the party that created them. Neither KODE Labs nor partners hold exclusive rights over general fault concepts. Export and import permissions are managed at the role level. Only super admins can access these features. Backend logs track who created, exported, and imported each routine. > [!NOTE] > > This feature works for both FDD routines and FTT workflows. The same export and import process applies to both module types. ## Next steps > [card] [Routine logic blocks](/products/fdd/routine-logic-blocks) > > Explore the available block types for building routine logic. > [card] [Routine library](/products/fdd/routine-library) > > Browse pre-configured routines for air-side, chilled water, and hot water systems. > [card] [FDD configuration](/products/fdd/configuration) > > Apply routines to your devices and configure monitoring parameters. # FDD settings Source: https://docs.kodelabs.com/products/fdd/settings Configure FDD priorities, acknowledgment behavior, table column visibility, fault triage rules, and event triage rules from the Settings page. ## Acknowledgment The Acknowledgment tab controls comment requirements when users acknowledge events. It does not control who can acknowledge. Administrators manage access through the **Acknowledge FDD events** Write permission in Launchpad. Its `AssignedInEvent` constraint limits acknowledgment to assigned users by default. Disabling the constraint lets that role acknowledge any accessible FDD event. ![FDD Settings page showing the Acknowledgment tab with a single option: Acknowledgment with Comments toggle enabled, with the description Acknowledge events and leave a comment to maintain clarity and accountability, and a Save button at the bottom right](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-settings-acknowledgment.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b5af0fbf75ddab35cd4a35e813858a11) The Acknowledgment tab lets you require comments when acknowledging events **Acknowledgment with Comments** `Toggle` When enabled, users must leave a comment when acknowledging an event. This maintains clarity and accountability by requiring documentation of the acknowledgment action. Select `Save` to apply changes. ## Table Management The Table Management tab controls column visibility and ordering across Events, Incidents, and Faults tables throughout your portfolio. Each table type maintains independent column settings. ![FDD Settings Table Management tab showing three column groups side by side: Event Columns with 17 total columns and 17 active showing Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, Priority, and Work Order Url with blue toggles, Incident Columns with 13 total columns and 12 active showing Incident ID, Name, Building, Events, Areas, Priority, Devices, Start Time, End Time, and Duration, and Fault Columns with 14 total columns and 14 active showing Device, Routine, Status, Est Cost, Occurrences, Duration, Time in Fault Per Day, Watchers, Labels, and Last Comment, all last changed Nov 25 9:44 AM, with a Reset to default button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-settings-table-management.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=bb8390a4961301a0ec1193016eaa0d0f) Table Management shows column toggles for Event, Incident, and Fault tables side by side Each column group displays a count indicator (for example, "Total columns: 17, Active columns: 17") and the date of the last change. ### Configure columns * **Toggle visibility** -- use the switch next to each column name to show (blue) or hide (gray) the column * **Reorder columns** -- click and hold the drag handle next to any column name, drag to the desired position, and release ### Apply changes | Action | Behavior | | - | - | | **Apply changes** | Applies table management changes to all buildings across the system | | **Keep editing** | Returns to the editor without saving | | **Reset to default** | Restores the original KODE OS column settings immediately | When you select `Apply changes`, a confirmation dialog appears. ![Apply table management changes confirmation dialog stating You're about to apply these table management changes to all buildings, The edits aren't saved yet, When applied updates will roll out across the system, with Keep editing and Apply changes buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-settings-table-apply.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=fb40f80c747e1d4f76e6b5b6c4b93b64) The confirmation dialog warns that changes will roll out across the system > [!WARNING] > > Resetting to default applies instantly and affects all users portfolio-wide. Coordinate with your team before resetting. > [!NOTE] > > Individual users can customize their own column preferences per building. User preferences override the organization's portfolio or building-level settings. ### Column reference > [accordion] Event columns (17 total) > > | Column | Description | > | - | - | > | Name | The name of the event | > | Device | The device associated with the event | > | Device Type | The type of device | > | Point Name | The specific data point name from the device | > | Point Value | The value of the data point at the time of the event | > | Start Time | When the event began | > | End Time | When the event ended | > | Duration | The total duration of the event | > | Priority | The priority level assigned to the event | > | Work Order Url | Link to the associated work order | > | SLA | Service level agreement status for the event | > | Area | The area where the event occurred | > | Building | The building where the event occurred | > | Assignees | Users assigned to the event | > | Event ID | Unique identifier for the event | > | Incident ID | Linked incident identifier | > | Ack'ed | Whether the event has been acknowledged | > [accordion] Incident columns (13 total) > > | Column | Description | > | - | - | > | Incident ID | Unique identifier for the incident | > | Name | The name or title of the incident | > | Building | The building where the incident occurred | > | Events | The number of events associated with this incident | > | Areas | The areas affected by the incident | > | Priority | The priority level assigned to the incident | > | Devices | The devices involved in the incident | > | Start Time | When the incident began | > | End Time | When the incident was resolved | > | Duration | The total duration of the incident | > | Assignees | Users assigned to the incident | > | Ack'ed | Whether the incident has been acknowledged | > [accordion] Fault columns (14 total) > > | Column | Description | > | - | - | > | Device | Device associated with the fault | > | Routine | FDD routine that detected the fault | > | Status | Current status of the fault | > | Est. Cost | Estimated cost impact of the fault | > | Occurrences | Number of fault occurrences during the date range | > | Duration | Total active duration of the fault | > | Time in Fault Per Day | Daily time series showing cumulative time in fault state | > | Watchers | Users monitoring the fault | > | Labels | Tags applied to the fault (Reopened, Overdue, Work Order) | > | Last Comment | Most recent comment on the fault | > | Last Activity | Timestamp of the most recent action on the fault | > | Area | The area where the fault occurred | > | Work Order Url | Link to the associated work order | ## Triage Rules The Triage Rules tab includes fault rules and [event triage rules](#event-triage-rules). Fault rules manage fault statuses and labels based on time-based conditions. Each fault rule has a description, an optional label, a configurable time parameter, and an enabled toggle. ![FDD Settings Triage Rules tab showing a table with columns for Triage Rule, Description, Label, Parameter, and Enabled, listing six rules: Reopened with label Reopened and 1 days parameter, Overdue with label Overdue and 1 days parameter, Work Order Created with label Work Order and no parameter, Work Order Closed with label Work Order and no parameter, Revert In Progress to Open with no label and 2 days parameter, Revert Suppressed to Open with no label and 2 days parameter, and Revert Resolved to Open with no label and 2 days parameter, all with blue enabled toggles, and a Reset to default button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-settings-triage-rules.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=07578b700642811d695c32aa8e7bc548) Triage Rules automate fault status changes and label assignments based on configurable time windows | Rule | Description | Label | Default parameter | | - | - | - | - | | **Reopened** | If a fault reoccurs within the configured time window after being marked `Resolved`, apply the `Reopened` label | Reopened | 1 day | | **Overdue** | If a fault remains `Open` or `In Progress` beyond the configured time window, apply the `Overdue` label | Overdue | 1 day | | **Work Order Created** | When a work order is created from the fault, set status to `In Progress` and apply the `Work Order` label | Work Order | -- | | **Work Order Closed** | When CMMS readback shows the work order is `Closed`, set status to `Resolved` and remove the `Work Order` label | Work Order | -- | | **Revert In Progress to Open** | If a fault remains `In Progress` beyond the configured time window, set status to `Open` | -- | 2 days | | **Revert Suppressed to Open** | If a fault remains `Suppressed` beyond the configured time window, set status to `Open` | -- | 2 days | | **Revert Resolved to Open** | If a fault remains `Resolved` beyond the configured time window, set status to `Open` | -- | 2 days | Use the toggle in the `Enabled` column to activate or deactivate individual rules. Select `Reset to default` to restore the original fault triage rule configuration. ## Event triage rules Event triage rules compare a live event with the work order status your CMMS sends back. They apply when the building uses a work order connector. Open `FDD` > `Settings` > `Triage Rules`, then the Event Triage Rules section. | Rule | Behavior | Default | | - | - | - | | **Bad closure** | Reopens the work order when the alarm is still active after the CMMS closes it, once the grace period ends | zero minutes | | **Recurrence reopen** | Reopens the original work order when the same alarm returns inside the window | seven days | | **Hold and release** | Holds work for low-priority routines until a high-priority routine fires at the same building, then releases the held work orders | `P1` and `P2` release the held work | | **Carry forward** | Keeps the open work order on a new alarm for the same device | On | | **Self-resolving cancellation** | Cancels the work order when the alarm stays inactive for the hold time. The timer resets if the alarm returns | 24 hours | To place several active events on one work order yourself, see [Group events into one work order](/products/fdd/events#group-events-into-one-work-order). ## Next steps > [card] [Events](/products/fdd/events) > > Monitor and investigate real-time fault events across your building equipment. > [card] [Notification policies](/products/fdd/notification-policies) > > Control how FDD delivers alerts through email, SMS, push, and phone calls. > [card] [Handling FDD updates](/products/fdd/handling-updates) > > Understand how configuration changes affect active events and incidents. # Build your first FDD routine Source: https://docs.kodelabs.com/products/fdd/tutorials/build-your-first-routine Learn how FDD alarms and events work, then build a flexible sensor-to-setpoint routine, test it, and enable it on a device. FDD ## Build your first FDD routine Learn what FDD watches for, then build a simple sensor-over-threshold rule you can reuse on almost any equipment. Beginner About 30 min ![Completed VAV Over Setpoint logic canvas with sensor, setpoint, deadband, sum, greater than, debounce, and alarm trigger blocks](/images/kode-os/fdd/tutorials/fdd-tutorial-completed-canvas.png) Progress /
      Step 0 ### What does FDD do? FDD (Fault Detection and Diagnostics monitors equipment and surfaces operational issues in real time.) watches building equipment for conditions that need attention. You define the rule once as a routine. KODE then evaluates live point data and opens an event when the rule holds true. A useful fault always answers four questions: ![Example fault text broken into Start Time, Device, Condition, and Duration](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-fault-definition.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c4df71c12274395be68d37e59423f26c) Every fault combines a start time, device, condition, and duration **Alarms** are the simplest checks. They usually watch one or two points and fire as soon as the condition is true. Think zone temperature over a max, or a fan failure status. **Events** are richer. A routine can combine sensors, setpoints, parameters, and timing blocks. When the Alarm Trigger receives `true`, FDD opens an event you can triage on the Events page. ![Events page showing Pause Streaming, Last 7 Days date range, Filters, priority cards for Total 297, Life-Safety 0, Critical 2, Warning 66, and Alert 229, and a Table View of active events with Name, Device, Device Type, Point Name, Point Value, Start Time, End Time, Duration, and Ack'ed columns](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-events-list.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=f2464097b2f7a916f2bd137070d7718b) Events list with priorities, filters, and active fault events This walkthrough builds one event routine end to end: create the rule, test it, enable it on a device, then confirm the event. For the full concept map, see [What is Fault Detection and Diagnostics?](/products/fdd/overview). Step 1 ### Before you begin You will build a VAV zone air temperature greater-than-setpoint rule. Treat that as a starting pattern, not a one-off recipe. The same shape works for: * Sensor **greater than** setpoint (this walkthrough) * Sensor **less than** setpoint (swap Greater Than for Less Than) * Sensor versus a **Number parameter** when the device has no setpoint point You only need a readable sensor value and a threshold to compare against. The threshold can come from another point or from a parameter you set yourself. Confirm the following before you build: * Access to `FDD` on a building where you can create and enable routines * At least one online VAV with zone air temperature sensor and setpoint points templated (or a sensor plus a parameter threshold) * Prefer a non-production building or a device you can safely monitor while you learn > [!NOTE] > > Compatible devices appear in Configs only when they carry the canonical types and entities you select on the routine. Missing templating means an empty device list later. Step 2 ### Create the routine ![Routines page with callouts for FDD in the sidebar, Routines in the secondary menu, and the Create Routine button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-create-routine-nav.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=2a1711e9beecd92b1d5119f984ee8147) Open FDD, select Routines, then Create Routine Create a local routine and tell FDD which VAV points it may read. **1. Open Create Routine** In Cloud BMS, open `FDD`, select `Routines`, then select `+ Create Routine`. **2. Fill Workflow Details** On the `Workflow Details` tab, enter: | Field | Value | | - | - | | `Name` | `VAV Over Setpoint` | | `Description` | Alarms when zone air temperature stays above setpoint plus deadband | | `Recommended Type` | `Event` | | `Domains` | `Heating Issue` (or the domain your site uses) | | `Events Grouping` | `None` | | `Priority` | `Alert` | ![Workflow Details tab with Name VAV Over Setpoint, Recommended Type Event, Domains Heating Issue, Events Grouping None, Priority Alert, and a Vavs device group](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-workflow-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=346554b77ed5ff5f9fc1e8a4cc6e439a) Workflow Details for VAV Over Setpoint **3. Add VAV devices and ZTSS** Select `+ Add Devices`. Set `Name As` to `Vavs`, select the `vav` canonical, and select the `ZTSS` entity (Zone Temperature Control). `ZTSS` brings in `zone_air_temperature_sensor` and `zone_air_temperature_setpoint` so those fields appear in the Logic builder. First click includes an entity. Second click excludes it (shown in red). Include only what this routine needs. ![Add Devices dialog with Name As Vavs, vav canonical selected, ZTSS entity selected with Zone Temperature Control tooltip, and zone air temperature points listed on the right](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-add-devices-ztss.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=25b68295b919a709450400827a5ae72d) Add Devices with vav and ZTSS selected Select `Save` in the dialog to return to Workflow Details. Step 3 ### Build the detection logic Open the `Logic` tab. Drag blocks from the left panel onto the canvas and connect outputs to inputs. You build three layers: read the points, compare the sensor to a threshold, then delay and trigger the alarm. Substep 3.1 #### Add the read points ![Dragging two Number Point blocks onto the Logic canvas and setting Main sensor and Secondary setpoint fields](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-add-number-points.gif?s=bb523a7706d84dfdeeee591e91d48e49) Drag two `Number Point` blocks from Read onto the canvas. | Block | Name | Role | Field | | - | - | - | - | | Sensor | `ZAT Sensor` | `Main` | `zone_air_temperature_sensor` | | Setpoint | `ZAT Setpoint` | `Secondary` | `zone_air_temperature_setpoint` | Every routine needs exactly one `Main` read block. The system uses that point as the reference when an event links to other Cloud BMS modules. Set all other reads to `Secondary`. > [!TIP] > > No setpoint on the device? Skip the setpoint Number Point. In the next substep, compare the sensor to a Number parameter instead. Substep 3.2 #### Compare sensor to threshold A deadband (An allowable offset from the setpoint. The fault condition is true only after the sensor crosses setpoint plus (or minus) this offset.) is a buffer around the setpoint. Without it, a sensor that briefly ticks one degree over setpoint can raise an event. With it, the zone must move further past the setpoint before the comparison turns true. Use a deadband when you want a more severe, less noisy alert. You can still tune the value later in Configs without rewriting the logic. **1. Add Setpoint Deadband** Drag a `Number` parameter from Parameters. Set `Name` to `Setpoint Deadband` and `Value` to `5`. ![Adding a Number parameter block named Setpoint Deadband with value 5](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-add-deadband.gif?s=1a75a7700ee55382a7711f2ea523821e) **2. Sum setpoint and deadband** Drag a `Sum` block. Connect `ZAT Setpoint` `Value` to the first operand. Connect `Setpoint Deadband` `Output` to the second operand. The Sum result is your effective threshold: setpoint plus deadband. ![Connecting setpoint Value and Setpoint Deadband Output into a Sum block](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-add-sum.gif?s=457d55548f9ddbad763a35a747d6235e) **3. Add Greater Than** Drag a `Greater Than` block. Connect `ZAT Sensor` `Value` to the left operand. Connect the Sum `Result` to the right operand. The block outputs a boolean `Result` that is true when the sensor is greater than setpoint plus deadband. ![Connecting sensor Value and Sum Result into a Greater Than block](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-greater-than.gif?s=a331ede9aa1a6022ee7e0a70173e7b02) > [!NOTE] > > Building a less-than rule? Use `Less Than` instead. Comparing to a fixed limit with no setpoint? Wire the sensor to Greater Than and use the Number parameter as the right operand. Skip Sum. Substep 3.3 #### Add delay and alarm trigger Deadband reduces how often the condition becomes true. Debounce reduces how quickly a true condition becomes an event. Together they filter brief spikes and leave more meaningful alerts. **1. Add Debounce** Drag a `Debounce` block. Set the unit to `Minutes` and the count to `15`. Connect the Greater Than `Result` to the Debounce input. Debounce outputs a value only when that value stays unchanged for the full period. ![Adding a Debounce block set to 15 minutes and connecting Greater Than Result to Debounce](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-debounce.gif?s=a37ef8445ceba38790664640b5d23f8d) > [!NOTE] > > Library routines often expose delay as an `Alarm On Delay` Number parameter. Debounce is the timing block that holds a stable true condition before the alarm. **2. Add Alarm Trigger** Drag an `Alarm Trigger` block. Connect the Debounce `Output` to it. When Alarm Trigger receives `true`, FDD generates an event. Without this block, the routine cannot create events. ![Connecting Debounce Output to an Alarm Trigger block](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-alarm-trigger.gif?s=a96e72a5db3ada3357f3c9841a1e4fef) ![Completed logic canvas with ZAT Sensor Main, ZAT Setpoint Secondary, Setpoint Deadband, Sum, Greater Than, Debounce at 15 minutes, and Alarm Trigger](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-completed-canvas.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=dad98064040d4273ee3d62b4faed2ae8) Completed VAV Over Setpoint pipeline Step 4 ### Test in the debugger ![Debugger tab showing Setpoint Deadband 5, ZAT Sensor 50, ZAT Setpoint 40, and Simulator log with Event Started and Event Ended](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-debugger.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5254c6ba50556d96ca5c2749510af8c2) Debugger with over-threshold inputs and Event Started in the Simulator Open the `Debugger` tab and prove the rule before you enable it on live devices. **1. Review PARAMS** Confirm `Setpoint Deadband` is `5` (or the value you want to test). **2. Start Simulation** Select `Start Simulation`. **3. Send an over-threshold case** Set `ZAT Sensor` above setpoint plus deadband (for example, sensor `50` and setpoint `40`). Set status to `ok`, then select `Send`. With a 15-minute Debounce, wait for the Simulator to log `Event Started` after the delay. **4. Send a should-not-fire case** Set the sensor below the threshold and select `Send`. Confirm the routine does not start a new event for that input. **5. Save the routine** Select `Save`. The routine appears in the Routines list and becomes available under Configs. > [!TIP] > > Debounce runs in real time during simulation. Temporarily set Debounce to seconds to speed up testing, then return to minutes before you save. Step 5 ### Configure and enable ![Batch Configuration page with callouts for Configs in the sidebar, VAV Over Setpoint selected, and the Configure button](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/tutorials/fdd-tutorial-configs-configure.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=8114c0e9810f6c7cda07e939bcf83383) Select VAV Over Setpoint on Configs, then select Configure Apply the routine to devices and start monitoring. **1. Open Configs** Open `FDD` > `Configs`. Search for `VAV Over Setpoint`. **2. Select the routine and Configure** Select the checkbox for `VAV Over Setpoint`, then select `Configure` in the bottom toolbar. **3. Choose a notification policy** Batch configure asks you to pick a notification policy (Defines which contacts receive notifications and through which channels.) before it finishes. Choose an existing policy for this building, or create one under `Policies` first. See [Notification policies](/products/fdd/notification-policies) if your site does not have one yet. **4. Finish device and status setup** Select compatible VAVs. In `Routine Params`, set `Setpoint Deadband` for this building. In `Status Setup`, turn on `Event Config` so the routine can generate events. Enable `Routine Config` so the folder monitors devices. **5. Configure and Enable** Select `Configure and Enable` when you want monitoring to start immediately. > [!NOTE] > > If your site always prompts for a policy during Configure, that is expected for this path. You can change the assigned policy later in Config Details under Notification Settings. See [FDD configuration](/products/fdd/configuration) for Multi-Config folders and detailed settings. Step 6 ### Confirm the event Close the loop by confirming the routine can produce a live event. **1. Open Events** Open `FDD` > `Events` > `List`. **2. Find your routine** Filter or search for `VAV Over Setpoint` (or the device you enabled). **3. Open the event report** Open the event and confirm the device, parameters, and condition match the rule you built. > [!TIP] > > You created a flexible sensor-to-threshold routine, tested it in the debugger, enabled it on a device, and confirmed an event in FDD. > [accordion] Events are not generating > > Confirm `Event Config` and `Routine Config` are on. Check that Debounce and deadband match real conditions. Confirm the routine status is Enabled. > [accordion] Too many notifications > > Increase Debounce duration or widen `Setpoint Deadband` to filter transient conditions. > [accordion] No compatible devices found > > Verify devices have the correct point templating. Routines match devices from the canonical types and entities on the routine. ## Related reading > [card] [What is Fault Detection and Diagnostics?](/products/fdd/overview) > > Learn how events, incidents, and faults fit together. > [card] [Routine logic blocks](/products/fdd/routine-logic-blocks) > > Explore comparison, timing, parameter, and alarm blocks beyond this walkthrough. > [card] [FDD configuration](/products/fdd/configuration) > > Tune devices, parameters, Multi-Config folders, and status setup. > [card] [Notification policies](/products/fdd/notification-policies) > > Control who gets notified and through which channels when events fire. > [card] [Events](/products/fdd/events) > > Triage, acknowledge, and investigate events from the Events list. > [card] [Routine library](/products/fdd/routine-library) > > Browse pre-built routines you can configure without building logic from scratch. # Work order integration Source: https://docs.kodelabs.com/products/fdd/work-orders Configure automatic work order generation from FDD events and track work order status through the Work Order View. FDD can automatically generate work orders in your CMMS system when fault events are triggered. You configure work order integration through the External Data Source section in the FDD configuration page, and track all generated work orders from the Work Order View. ## Work Order View Select `Work Order View` in the FDD sidebar to access the Generated Work Orders page. This page lists every work order that FDD has created across all routines. ![Generated Work Orders page showing a table of work orders with columns for Title, Description, Priority, Read Back Status, Assignee, Source, Work Order Link, Work Order Type, Created At, Due Date, and Last Comment](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-work-orders-list.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=6c6f8830fd8f9c9833c5cba119c29447) The Generated Work Orders page lists all work orders with sortable columns and filters The table includes the following columns: | Column | Description | | - | - | | `Title` | Name of the work order generated from the routine | | `Description` | Routine description associated with the work order | | `Priority` | Priority level assigned to the work order | | `Read Back Status` | Current status returned from the CMMS system (for example, Problem Solved) | | `Assignee` | Person or team assigned to the work order | | `Source` | Links to the originating event | | `Work Order Link` | Direct link to the work order in the CMMS system | | `Work Order Type` | Category of the work order (for example, Smart Device - Leak Detection) | | `Created At` | Timestamp when the work order was created | | `Due Date` | Target completion date | | `Last Comment` | Most recent comment on the work order | Use the search bar and `Filters` button to narrow results by any column value. ### Work order details Select a work order row to open the details panel on the right side. The panel displays all metadata for the selected work order. ![Work Order View with a selected row showing the details panel with Priority, Notify Status, Read Back Status, Work Order Type, Created and Updated timestamps, Due Date, Routine, Source link to the event, Device, Area, Work Order Link, and Last Comment fields](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/fdd/kode-os-fdd-work-order-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4dc91a83e1defe560343af33824691cf) Select a work order to view its full details in the side panel The details panel shows: | Field | Description | | - | - | | `Priority` | Priority level from the CMMS configuration | | `Notify Status` | Whether the work order notification was sent successfully | | `Read Back Status` | Status update received from the CMMS system | | `Work Order Type` | The configured work order category | | `Created` / `Updated At` | Creation and last update timestamps | | `Due Date` / `Completion Time` | Target and actual completion dates | | `Routine` | The FDD routine that generated the work order | | `Source` | Link to the originating event report | | `Device` / `Area` | The device and area associated with the fault | ## Work orders in event reports When you open an event report, the Work Order panel on the right side shows all work orders generated for that event. Each work order card displays its creation time, notify status, last update, sub status, and the full CMMS field mapping. ![Event report for Leak Detection showing a timeline chart with Normal and Alarm states, and a Work Order panel on the right listing Created At, Notify Status, Last Update, Sub Status, Work Order URL, Work Order Type, Data Source, Entity, Action, Title, Description, Category, Subcategory ID, and Location fields](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-work-order.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=3e937b461529d47cbe328dddafeee0e3) The event report displays work order details alongside the fault timeline ### Generate a work order from an event You can manually generate a work order directly from an event report. This is useful when an event does not have a pre-configured external source or when you need to create an additional work order. To create one work order for each of several events from the Events list, see [Create work orders per event](/products/fdd/events#create-work-orders-per-event). **1. Open the event report** Navigate to the event and open its report. The Work Order panel appears on the right side. ![Event report showing the Work Order panel on the right with an existing work order card and a plus button in the panel header](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-event-work-order-panel.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=ba7d0518c658d8e9cc03d24596c404b1) **2. Add a work order** Select the `+` button in the Work Order panel header. The Add Work Order dialog opens with fields for your CMMS integration. ![Add Work Order dialog showing fields for Name, Data Source, Entity, Action, Title, Description, Category, Subcategory ID, Location, and Device Link, with dynamic variable tokens listed at the bottom](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-add-work-order-event.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=4e1fd75cfbdcee75e508a32a7c511e5e) Fill in the required fields: * `Name` -- a descriptive name for the work order * `Data Source` -- your CMMS system (for example, QR Connect API) * `Entity` -- the entity type (for example, WorkOrder) * `Action` -- the action to perform (for example, Create Work Order) * `Title` and `Description` -- the work order title and description * `Category` and `Subcategory ID` -- category fields for your CMMS * `Location` and `Device Link` -- location and device reference Use the dynamic variable tokens at the bottom of the dialog to populate fields automatically. Select a token to insert it into the active field. **3. Save the work order** Select `Save` to generate the work order. The new work order appears in the Work Order panel and is sent to your CMMS system. ## Create work orders per event From the [Events list](/products/fdd/events#events-list), select multiple events and use `Create Work Order` to create **one individual work order per event**. You can submit the batch as-is or step through each form before sending. Batch-created work orders appear in the [Work Order View](#work-order-view) alongside work orders created from a single event report. For the full multi-select flow, readiness statuses (`To Be Completed`, `Ready`, `Sent`, `Not Sent`), Send Work Orders versus Review Each, and retry of incomplete items, see [Create work orders per event](/products/fdd/events#create-work-orders-per-event). To place several events on one work order, see [Group events into one work order](/products/fdd/events#group-events-into-one-work-order). Rules that reopen, hold, carry forward, or cancel those work orders live in [Event triage rules](/products/fdd/settings#event-triage-rules). ## Configure work order integration Work order integration is configured through the External Data Source section in the FDD [configuration page](/products/fdd/configuration). You can also set an external data source on a [notification policy](/products/fdd/notification-policies). A policy-level source applies to all configurations that use that policy. A configuration-level source overrides the policy for that configuration only. You add an external source to a routine's configuration folder, and FDD automatically generates work orders whenever that routine triggers an event. **1. Open the routine configuration** Navigate to `FDD` > `Configs` and select the routine you want to configure. You can search for the routine name in the Batch Configuration list. ![Batch Configuration page showing a Leak Detection routine with Enabled event status, Not Configured fault status, Critical priority, and Local source](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-batch-work-order.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=c2f692c72f95c1d1bcac52a7ffcd1c5d) **2. Navigate to External Data Source** Select the routine name to open the detailed configuration page. In the right panel, locate the `External Data Source` section. Select `+ Add External Source` to open the configuration dialog. ![Configuration detail page showing Folder 1 with a device listed, and the External Data Source section in the right panel with an Add External Source button](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-config-external-source.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=b5e2023485268f65f66ca7d293ff6616) **3. Configure the external source** Fill in the required fields in the Add External Source dialog. Each field maps to a corresponding field in your CMMS system. ![Add External Source dialog showing fields for Name, Data Source, Entity, Action, Notification, Title, Description, Category, Subcategory ID, Location, Device Link, and Priority, with dynamic variable tokens listed at the bottom](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/fdd/kode-os-fdd-add-external-source.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=952059857dd6d082f2171fe3f851b7bf) **Name** `Field` A descriptive name for the external source configuration. **Data Source** `Dropdown` The CMMS system to send work orders to (for example, QR Connect API). **Entity** `Dropdown` The entity type in the CMMS system (for example, WorkOrder). **Action** `Dropdown` The action to perform when an event triggers (for example, Create Work Order). **Notification** `Dropdown` The notification type to send to the CMMS system (for example, CREATE). **Title** `Field` The work order title. Use dynamic variables like `{{routines.name}}` to populate automatically. **Description** `Field` A description of the work order. **Category** `Dropdown` The work order category in the CMMS system (for example, Smart Device). **Subcategory ID** `Dropdown` The subcategory identifier (for example, Leak Detection). **Location** `Field` The location for the work order. Use `{{location}}` to populate dynamically. **Device Link** `Field` A link to the device in KODE OS. Use `{{URL}}` to populate dynamically. **Priority** `Field` The priority level for the work order in the CMMS system. The dialog provides dynamic variable tokens you can insert into text fields. Select any token to add it to the active field: | Variable | Description | | - | - | | `Routine Name` | Name of the FDD routine | | `Building` | Building where the fault occurred | | `Start Time` | Timestamp when the event started | | `View Event Link` | Link to the event report in KODE OS | | `Priority` | Priority level of the event | | `Next Escalation` | Next escalation step | | `Location` | Location of the device | | `Device Name` | Name of the affected device | | `Floor` | Floor where the device is located | | `Priority Level` | Numeric priority level | | `Routine Description` | Description of the routine | | `Client Name` | Client name | | `Point Value` | Current value of the point | | `Point Name` | Name of the monitored point | | `Acknowledge Event Link` | Link to acknowledge the event | | `Event Status` | Current status of the event | Select `Save` to create the external source. **4. Save the configuration** Select `Save Folder` to save the configuration. ### Manage external sources After creating an external source, it appears in the External Data Source section with a status indicator. Select the three-dot menu on an existing source to edit or delete it. ![External Data Source panel showing an existing source with a dropdown menu offering Edit and Delete options](https://mintcdn.com/kodelabs/SxbaONoYYoMWCQfA/images/kode-os/fdd/kode-os-fdd-external-source-menu.png?fit=max\&auto=format\&n=SxbaONoYYoMWCQfA\&q=85\&s=0c8d11e8c9ee226654a068fc6c5d2a75) Select the three-dot menu on an external source to edit or delete it > [!NOTE] > > **Automatic vs. manual work orders** -- An external source on the routine creates a work order when FDD generates an event. You can also create a work order manually from an existing event. Closing the event in KODE OS does not close the work order. Close the work order in the connected CMMS; its read-back status then updates in KODE OS. ## Next steps > [card] [Events](/products/fdd/events) > > Monitor and investigate real-time fault events across your building equipment. > [card] [FDD configuration](/products/fdd/configuration) > > Configure routines, set thresholds, and assign priorities for your site. > [card] [Notification policies](/products/fdd/notification-policies) > > Control how FDD delivers alerts through email, SMS, push, and phone calls. # AHU workflows Source: https://docs.kodelabs.com/products/ftt/ahu-workflows Reference for all AHU functional testing workflows including cooling operation, heating operation, mixed damper operation, and VFD operation tests. Cloud BMS provides a library of pre-configured AHU (Air Handling Unit) functional testing workflows. Each workflow commands cooling, heating, dampers, or VFDs, reads sensor response, and scores pass or fail against thresholds. Use this page as a parameter and point-requirements lookup. For how scores are produced, see [How to read a score](/products/ftt/test-results#how-to-read-a-score). For deployment order, see the [Deployment guide](/products/ftt/deployment). Select a tab to open the workflow you need. *** > [tab] Cooling operation > > *This workflow tests an AHU (air handling unit) for its cooling operation. It verifies the AHU is running, eliminates outside sources of heating and cooling, and then commands cooling to confirm the unit can deliver cooled air.* > > > [!TIP] > > > > **Outcome:** This test verifies an AHU's ability to deliver cooled air when the cooling system is commanded on. > > > [!TIP] > > > > **Recommended schedule:** Run seasonally (when cooling is first needed) per AHU. Run when there are comfort complaints in a space or floor. Run when AHUs are installed and/or reprogrammed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | AHU | Discharge Air Pressure, Discharge Air Temperature, Mixed Air Temperature, Return Air Temperature, Cooling Command | > > ### Required pre-conditions > > 1. *AHU Occupancy Mode* is `Occupied` > > 2. *AHU Duct Pressure* exceeds `0.4psi` \[Pressure Min Threshold] > > 3. *AHU Return Air Temperature* is below `60°F` \[RAT Cooling Threshold] > > > [!WARNING] > > > > If any of these conditions are not met, the workflow stops and the test is archived. > > ### Workflow overview > > **1 Pre-Condition Check** > > * Verify device is `Occupied` > * *Duct Pressure* exceeds `Pressure Min Threshold` > * *Return Air Temperature* below `RAT Cooling Threshold` > > **2 Stop Active Heating** > > * **Success:** *Discharge Air Temperature* is within `10△°F` \[Heating - Delta] above *Mixed Air Temperature* > > **3 Stop Active Cooling** > > * **Success:** *Discharge Air Temperature* is within `10△°F` \[Cooling - Delta] below *Mixed Air Temperature* > > **4 Open Mixed Damper** > > * **Success:** *Mixed Air Temperature* is within `5△°F` \[Ventilation - Delta] below *Return Air Temperature* > > **5 Start Cooling** > > * **Control:** Command *Cooling* to `ON` > * **Success:** *Discharge Air Temperature* is `10△°F` \[Cooling - Delta] more than *Mixed Air Temperature*, or if *Mixed Air Temperature* is not available, *Discharge Air Temperature* exceeds `45°F` \[DAT Arb Cooling Threshold] > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `Pressure Min Threshold` \[0.4psi] | Minimum duct pressure required for the test to begin | > | 2 | `RAT Cooling Threshold` \[60°F] | Maximum return air temperature for the loop to provide cooling | > | 3 | `Loop Diff Pressure Min Threshold` \[3△°F] | Minimum loop system differential pressure | > | 4 | `Ventilation Delta` \[5△°F] | Temperature threshold tolerance for fully open mixed damper (delta below RAT) | > | 5 | `Cooling Delta` \[10△°F] | Threshold tolerance for cooling (delta between MAT and DAT) | > | 6 | `Heating Delta` \[10△°F] | Threshold tolerance for heating (delta between MAT and DAT) | > | 7 | `DAT Arb Cooling Threshold` \[45°F] | DAT below which there is indication of cooling | > | 8 | `Reaction Time` \[300sec] | Time to wait for actuators to complete their action | > | 9 | `Stabilization Time` \[60sec] | Time to wait for the system to stabilize after a command and conditions are met | > | 10 | `Measure After` \[60sec] | Time in seconds to wait before checking feedback readings | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Heating operation > > *This workflow will test an AHU (air handling unit) for its heating operation.* > > 1. First, we display the initial conditions of the equipment. > > 2. Then, KODE performs pre-condition checks to ensure the equipment is ready to be tested. > > 3. Once confirmed, KODE will stop cooling by commanding the chilled water valve to close fully. > > 4. Then, KODE will stop heating by commanding the steam valve to close fully. > > 5. Finally, we will command the steam valve to fully open to restart heating. > > > [!TIP] > > > > **Outcome:** This test will check an AHU's ability to deliver heat when its steam valve is fully opened. > > > [!TIP] > > > > **Recommended schedule:** Run seasonally (when heating is first needed) per AHU. Run when there are comfort complaints in a space or floor. Run when AHUs are installed and/or reprogrammed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | AHU | Discharge Air Pressure, Discharge Air Temperature, Mixed Air Temperature, Chilled Water Valve Percentage Command, Steam Valve Percentage Command | > > | HHW System | Primary Loop Heating Hot Water Valve Percentage Sensor | > > ### Required pre-conditions > > 1. *AHU Discharge Air Pressure* exceeds `AHU Minimum Discharge Air Pressure Threshold` > 2. *HHW System Valve* exceeds `Minimum HHW System Valve Threshold` > > **Variations:** There is a variant of this workflow that works with AHU hot water valves instead of steam valves. > > ### Workflow overview > > **1 Pre-Condition Check** > > * *AHU Discharge Air Pressure* exceeds `Discharge Air Pressure Minimum` > * *HHW System Valve* exceeds `HHW Loop Valve Minimum` > > **2 Stop Cooling** > > * **Control:** Command *AHU chilled water valve* to `CHW Valve Close Command` > * **Success:** *AHU Discharge Air Temperature* ≥ *AHU Mixed Air Temperature* - `Stop Cooling DAT-MAT Differential` > > **3 Stop Heating** > > * **Control:** Command *AHU steam valve* to `Hot Water Valve Close Command` > * **Success:** *AHU Discharge Air Temperature* ≤ *AHU Mixed Air Temperature* + `Stop Heating DAT-MAT Differential` > > **4 Start Heating** > > * **Control:** Command *AHU steam valve* to `Hot Water Valve Open Command` > * **Success:** *AHU Discharge Air Temperature* ≥ *AHU Mixed Air Temperature* + `Start Heating DAT-MAT Differential` > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `Discharge Air Pressure Minimum` | Minimum AHU discharge air pressure required for the test to begin running | > | 2 | `HHW Loop Valve Minimum` | Minimum primary HHW loop valve position for HWS to be considered enabled | > | 3 | `CHW Valve Close Command` | Percentage command to close the chilled water valve when stopping cooling | > | 4 | `Stop Cooling DAT-MAT Differential` | Differential between DAT and MAT for Stop Cooling test to run successfully | > | 5 | `Hot Water Valve Close Command` | Percentage command to close the hot water valve when stopping heating | > | 6 | `Stop Heating DAT-MAT Differential` | Differential between DAT and MAT for Stop Heating test to run successfully | > | 7 | `Hot Water Valve Open Command` | Percentage command to open the hot water valve when starting heating | > | 8 | `Start Heating DAT-MAT Differential` | Differential between DAT and MAT for Start Heating test to run successfully | > | 9 | `Min Sequence Duration` | Minimum length of time in seconds that a sequence should take to execute | > | 10 | `Max Sequence Duration` | Maximum length of time in seconds that a sequence should take to execute | > | 11 | `Stabilization Time` | Time in seconds the program will wait between sequences | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Mixed damper operation > > *This workflow will test an AHU (air handling unit) for its mixed air damper operation.* > > 1. First, we display the initial conditions of the equipment. > > 2. Then, KODE performs pre-condition checks to ensure the equipment is ready to be tested. > > 3. Once confirmed, KODE will open the mixed air damper and route 100% outdoor air to the air-handling unit. > > 4. Finally, KODE will close the mixed air damper and route 100% return air to the air-handling unit. > > > [!TIP] > > > > **Outcome:** This test evaluates an AHU's capability to regulate mixed air temperature by modulating the mixed air damper. > > > [!TIP] > > > > **Recommended schedule:** Run monthly per AHU. Run when there are comfort complaints in a space or floor. Run when AHUs are installed and/or reprogrammed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | AHU | Discharge Air Pressure, Outdoor Air Temperature, Mixed Air Temperature, Return Air Temperature | > > ### Required pre-conditions > > 1. *AHU Discharge Air Pressure* exceeds `AHU Minimum Discharge Air Pressure Threshold` > > **Variations:** There is a variant of this workflow that works with AHU outdoor air dampers instead of mixed air dampers. > > ### Workflow overview > > **1 Pre-Condition Check** > > * *AHU Discharge Air Pressure* exceeds `Discharge Air Pressure Minimum` > > **2 Open Mixed Damper** > > * **Control:** Command *AHU mixed air damper* to `Open Mixed Air Damper Command` > * **Success:** *AHU Outdoor Air Temperature* - `Open MAT-OAT Differential` ≤ *AHU Mixed Air Temperature* ≤ *AHU Outdoor Air Temperature* + `Open MAT-OAT Differential` > > **3 Close Mixed Damper** > > * **Control:** Command *AHU mixed air damper* to `Close Mixed Air Damper Command` > * **Success:** *AHU Return Air Temperature* - `Close MAT-RAT Differential` ≤ *AHU Mixed Air Temperature* ≤ *AHU Return Air Temperature* + `Close MAT-RAT Differential` > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `Discharge Air Pressure Minimum` | Minimum AHU discharge air pressure required for the test to begin running | > | 2 | `Open MAT-OAT Differential` | Differential between MAT and OAT for Open Mixed Damper test to run successfully | > | 3 | `Close MAT-RAT Differential` | Differential between MAT and RAT for Close Mixed Damper test to run successfully | > | 4 | `Open Mixed Air Damper Command` | Percentage command to open the mixed air damper to allow 100% outdoor air in | > | 5 | `Close Mixed Air Damper Command` | Percentage command to close the mixed air damper to allow 100% return air in | > | 6 | `Min Sequence Duration` | Minimum length of time in seconds that a sequence should take to execute | > | 7 | `Max Sequence Duration` | Maximum length of time in seconds that a sequence should take to execute | > | 8 | `Stabilization Time` | Time in seconds the program will wait between sequences | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] VFD operation > > *This workflow tests an AHU (air handling unit) for its variable frequency drive (VFD) operation. It verifies the AHU is running, confirms the unit is maintaining pressure at setpoint, then raises and lowers the duct static pressure setpoint to confirm the VFD responds correctly.* > > > [!TIP] > > > > **Outcome:** This test verifies an AHU's VFD can track duct static pressure setpoint changes in both directions. > > > [!TIP] > > > > **Recommended schedule:** Run monthly per AHU. Run when there are pressure or airflow complaints. Run when AHU VFDs are installed, replaced, or reprogrammed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | AHU | Duct Static Pressure Sensor, Duct Static Pressure Setpoint | > > ### Required pre-conditions > > 1. *AHU Occupancy Mode* is `Occupied` > > 2. *AHU Duct Pressure* exceeds `0.4psi` \[Pressure Min Threshold] > > 3. *Duct Static Pressure Sensor* is within `5%` \[Relative Tolerance] of setpoint > > > [!WARNING] > > > > If any of these conditions are not met, the workflow stops and the test is archived. > > ### Workflow overview > > **1 Pre-Condition Check** > > * Verify device is `Occupied` > * *Duct Pressure* exceeds `Pressure Min Threshold` > * *Duct Static Pressure Sensor* within `Relative Tolerance` of setpoint > > **2 Raise Duct Static Setpoint** > > * **Control:** Command *static pressure setpoint* to `Relative Modulation` above current setpoint > * **Success:** *Static pressure sensor* reads within `Relative Tolerance` of new setpoint > > **3 Lower Duct Static Setpoint** > > * **Control:** Command *static pressure setpoint* to `Relative Modulation` below current setpoint > * **Success:** *Static pressure sensor* reads within `Relative Tolerance` of new setpoint > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `Relative Modulation` \[20%] | Percentage to change the setpoint from its current value | > | 2 | `Relative Tolerance` \[5%] | Percentage tolerance between sensor and setpoint after the change to confirm success | > | 3 | `Nominal Tolerance` \[0.1psi] | Absolute tolerance between sensor and setpoint after the change to confirm success | > | 4 | `Pressure Min Threshold` \[0.4psi] | Minimum duct pressure required for the test to begin | > | 5 | `Reaction Time` \[300sec] | Time to wait for actuators to complete their action | > | 6 | `Stabilization Time` \[60sec] | Time to wait for the system to stabilize after a command and conditions are met | > | 7 | `Measure After` \[60sec] | Time in seconds to wait before checking feedback readings | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). ## Next steps > [card] [VAV workflows](/products/ftt/vav-workflows) > > Explore the VAV workflow library for damper, heating, and airflow tracking tests. > [card] [FCU workflows](/products/ftt/fcu-workflows) > > Explore the FCU workflow library for fan, heating, and cooling tests. > [card] [Heat pump workflows](/products/ftt/hp-workflows) > > Explore the heat pump workflow for combined heating and cooling tests. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule automated testing. # Deployment guide Source: https://docs.kodelabs.com/products/ftt/deployment Roll out FTT across a building: draft projects, calibrate parameters, and set production schedules in Cloud BMS. Use this guide when you roll out FTT for operators and commissioning teams. It covers draft projects, small-scale calibration, client review, and production schedules. If you have not run a single test yet, complete [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device) first. Confirm how scores are produced before you schedule building-wide work. ## Who this guide is for * Building engineers and operators who will review weekly results * Commissioning agents who calibrate thresholds and seasonal cadence * Implementation teams who set the first recurring projects Custom workflow authoring is separate. See the [Workflow creator guide](/products/ftt/workflow-creator-guide) only when the library does not cover the sequence you need. ## Standard workflows The following workflows are the standard set for buildings with compatible equipment: | Workflow | Device type | | - | - | | VAV Induced Heating | VAV | | VAV Damper Min/Max | VAV | | FCU Heating | FCU | | FCU Cooling | FCU | | AHU Heating Operation | AHU | | AHU Mixed Damper Operation | AHU | ### Additional workflows Deploy these workflows as needed based on site requirements: | Workflow | When to use | | - | - | | VAV Stuck Damper Testing | When Min/Max flow is not compatible, or the site needs a simpler damper test | | VAV Airflow Setpoint Tracking | When the airflow setpoint is writable but the damper is not | ## Choose workflows by season | Season | Recommended workflows | | - | - | | Spring through summer | VAV Damper Operation, FCU Cooling | | Fall through winter | VAV Induced Heating, FCU Heating | Match the library page to the component you need to score. See [VAV workflows](/products/ftt/vav-workflows), [FCU workflows](/products/ftt/fcu-workflows), [AHU workflows](/products/ftt/ahu-workflows), and [Heat pump workflows](/products/ftt/hp-workflows). ## Phase 1: create projects and check compatibility **1. Create draft projects** Create projects for each applicable workflow and save them as drafts. Select a workflow from the library and review its parameters before assigning devices. ![Create Project step 1 showing workflow list with AHU Heating Operation, AHU Mixed Damper Operation, AHU VFD Operation, AHU Cooling Operation, HP Heating Cooling Operation, V2 VAV Damper Operation, and V2 VAV Induced Heating from Library source, with Parameters panel showing Pressure Min Threshold 0.40, RAT Heating Threshold 75, Ventilation Delta 5, Cooling Delta 10, Heating Delta 10, DAT Arb Heating Threshold 85, and Reaction Time 300](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-create-project-workflow.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d09da9c684f85827ce019464e830d985) Select a workflow from the library and review its default parameters **2. Review compatibility** Review the compatibility results for each project. Devices that lack required points or writable points appear as incompatible. Address templating or write-access issues before proceeding. ## Phase 2: calibrate and validate **1. Run small-scale tests** For each workflow, test five devices or one floor. The goal is to validate the following: * Points are writable * Equipment responds to commands * Parameters are adequately adjusted * At least 80% of tests pass or produce valid results **2. Tune parameters** Adjust workflow parameters based on initial results. Common adjustments include increasing max sequence duration for slower equipment or modifying threshold multipliers for different equipment generations. ![Edit Task dialog Details tab showing Task Name Floor 02, Start Date 2026-05-18, Start Time 16:00, Notify Users and Roles dropdowns, and Parameters section with Max Sequence Duration 600, Min Sequence Duration 30, Stabilization Time 30, Chilled Water Valve Close Cmd 0, Stop Cooling DAT Threshold 70, Hot Water Valve Close Cmd 0, Stop Heating DAT Threshold 80, Hot Water Valve Open Cmd 100, and Start Heating DAT Threshold 100](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-edit-task-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4a51c95eaaaa0bd1a8e27e3669d354e9) Edit individual task parameters to fine-tune thresholds for specific floors or equipment When a sequence fails, open the test report and compare the sensor reading to the threshold. See [How to read a score](/products/ftt/test-results#how-to-read-a-score). Retune only after you confirm the command wrote successfully. **3. Review results with the client** Present initial test results and discuss findings. The test detail report shows the step-by-step sequence with pass/fail indicators for each stage. ![Test sequence showing Start Heating step FAILED after 10 minutes with Discharge Temp 21.2 versus Temperature Threshold 22, Heating failed to start, and Finished step showing final Score 66.67 percent with red indicators](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-failed-score.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6735b702794cd88a57b061cee571c6b3) A completed test result showing passed and failed sequences with a final score Use this opportunity to confirm the testing schedule and set expectations. ## Phase 3: set the testing schedule After calibration, work with the building team to establish a production testing schedule. ### Scheduling recommendations * **Weekly testing on low-occupancy days**: creates a manageable workload and cadence for operators to review results * **Late afternoon timing**: equipment runs at steady state compared to startup hours, and late afternoon minimizes occupant impact * **Daily batches of 10 devices**: takes less than 30 minutes and systematically covers the entire building over time * **Recurring projects**: set up annual or continuous testing cycles for ongoing commissioning Choose floor, device-count, or single-group scheduling in the project wizard. See [FTT projects](/products/ftt/projects) for grouping guidance. ![Schedule step with Recurring and Advanced Settings enabled, showing Repeat After set to Project is completed, Delay of 1 Week, Ends After 10 occurrences, and task preview with Floor 02 and Floor 03 showing Estimated Next Occurrence dates of Jun 01 and Jun 08 2026](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-schedule-advanced-recurrence.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=c73b7b43c5765ec58f55a603618da99a) Configure recurring schedules with advanced settings for continuous commissioning ## Product support The KODE Labs product team maintains and supports the FTT workflow library: * New workflow variations are added within seven days of receiving clear requirements * Product support is available for consulting on workflow needs * Review and validate workflows at the project level before escalating to product support ## Next steps > [card] [FTT projects](/products/ftt/projects) > > Create and manage automated testing projects. > [card] [Test results](/products/ftt/test-results) > > Read scores and investigate failed sequences after calibration runs. > [card] [Workflow creator guide](/products/ftt/workflow-creator-guide) > > Build custom workflows when the library does not cover your sequence. > [card] [VAV workflows](/products/ftt/vav-workflows) > > Explore the VAV workflow library with parameters and success criteria. # FCU workflow library Source: https://docs.kodelabs.com/products/ftt/fcu-workflows Reference for all FCU functional testing workflows including fan operation, heating and cooling tests with and without fan verification, and FCU cooling operation. Cloud BMS provides a library of pre-configured FCU (Fan Coil Unit) functional testing workflows. Each workflow commands valves or the fan, reads sensor response, and scores pass or fail against thresholds. Use this page as a parameter and point-requirements lookup. For how FTT decides pass or fail on heating, see [How FTT decides if a heater works](/products/ftt/overview#example-how-ftt-decides-if-a-heater-works). To run one heating test before you schedule a project, see [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). Select a tab to open the workflow you need. *** > [tab] Cooling > > *This workflow will test an FCU for its cooling operation.* > > 1. First, we display the initial conditions of the equipment. > > 2. Then KODE performs precondition checks to ensure the equipment is ready to be tested. > > 3. Next we will stop heating by commanding the hot water valve to 0%. > > 4. Then we will stop cooling by commanding the chilled water valve to 0%. > > 5. Finally we will command the chilled water valve to 100% to start cooling. > > > [!TIP] > > > > **Outcome:** This test will check a FCU's ability to deliver cooling when the valve is set to 100%. > > > [!TIP] > > > > **Recommended schedule:** Run weekly per floor. Run when new FCUs are installed and programmed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | FCU | FCU Fan % Cmd, FCU Occupancy Cmd, FCU Chilled Water Valve Command, FCU Hot Water Valve Command | > > | AHU | Discharge Air Pressure | > > ### Required preconditions > > 1. *FCU Occupancy* = `Occupied` > 2. *FCU Fan Cmd%* > `5%` > 3. *Chiller Diff Pressure* > `10 PSI` > > **Variations:** Heating and cooling workflows with and without fan operation appear later on this page. > > ### Workflow overview > > | Test step | Workflow | > | - | - | > | **1 Pre-condition Check** | 1. FCU is `Occupied` 2. *FCU Fan Cmd%* > `5%` 3. *Chiller Diff Pressure* > `10 PSI` | > | **2 Stop Heating** | 1. **Control:** Cmd Hot Water Valve to `0%` 2. **Success:** *FCU DAT* is below the threshold | > | **3 Stop Cooling** | 1. **Control:** Cmd Cold Water Valve to `0%` 2. **Success:** *FCU DAT* is greater than the threshold | > | **4 Start Cooling** | 1. **Control:** Cmd Cold Water Valve to `100%` 2. **Success:** *FCU DAT* is below the threshold | > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `Chilled Water Valve Close Cmd` | Value used to command the chilled water valve when stopping cooling | > | 2 | `Stop Cooling DAT Threshold` | The DAT must be greater than this value to confirm cooling has stopped | > | 3 | `Hot Water Valve Close Cmd` | Value used to command the hot water valve when stopping heating | > | 4 | `Stop Heating DAT Threshold` | The DAT must be less than this value to confirm heating has stopped | > | 5 | `Chilled Water Valve Open Cmd` | Value used to command the chilled water valve when starting cooling | > | 6 | `Start Cooling DAT Threshold` | The DAT must be less than this value to confirm cooling has started | > | 7 | `FCU Fan Cmd % Low Limit` | If the Fan Cmd % is less than this value, the test will automatically archive | > | 8 | `Stabilization Time` | How long in seconds should the program wait when one sequence finishes, before moving onto the next? | > | 9 | `Min Sequence Duration` | What is the minimum length of time in seconds that a sequence should take to execute? | > | 10 | `Max Sequence Duration` | What is the maximum length of time in seconds that a sequence should take to execute? | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Fan operation > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the FCU is running.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** *Weight: 1/3* > > * Verify that *discharge temperature* is within `5△°F` \[Heating - Delta] above *mixed temperature* > > **Stop Active Cooling** *Weight: 1/3* > > * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* > > ### Test the Fan > > *It must also be verified that the fan can successfully be commanded to start and stop. If either of these conditions are not verified, then the testing will be aborted.* > > **Test 1: Stop the Fan** *Weight: 1/3* > > * Command the fan to `OFF` > * Pass if *Fan Speed* is reports to be less than `5%` \[Fan Max Threshold] > > **Test 2: Start the Fan** > > * Command the fan to `ON` > * Pass: *Fan Percentage* >= `10%` \[Fan Min Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Stop Fan Weight` \[1] | Weight on the overall test assigned to this sequence. All sequences sum up their weights and each weight is divided by this total. | > | `Fan Stop Command` \[%] | To what percentage do we want to test the stopping operation | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Stop Cooling Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Fan Start Command` \[100%] | To what percentage do we want to test the starting operation | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `Fan Current Max Threshold` \[0.2Amp] | The maximum amps threshold for a fan off status | > | `Fan Current Min Threshold` \[0.3Amp] | The minimum amps threshold for a fan on status | > | `DAT Cooling Arb Threshold` \[19°F] | The DAT below which there would be indication of cooling | > > *** > [tab] Heating w/ Fan Ops > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the FCU is running.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** *Weight: 1/7* > > * Verify that *discharge temperature* is within `5△°F` \[Heating - Delta] above *mixed temperature* > > **Stop Active Cooling** > > * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* > > ### Test the Fan > > *It must also be verified that the fan can successfully be commanded to start and stop. If either of these conditions are not verified, then the testing will be aborted.* > > **Test 1: Stop the Fan** *Weight: 1/7* > > * Command the fan to `OFF` > * Pass if *Fan Speed* is reports to be less than `5%` \[Fan Max Threshold] > > **Test 2: Start the Fan** *Weight: 1/7* > > * Command the fan to `ON` > * Pass: *Fan Percentage* >= `10%` \[Fan Min Threshold] > > ### Test Heating > > **Test 3: Start Heating Operation** *Weight: 4/7* > > * Command Heating to `ON` > * Pass if *zone temp* raised by at least `5△°F` \[Heating - Delta] OR > * Pass if *discharge temp* is greater than `28°F` \[DAT Heating Arb Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Stop Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Fan Stop Command` \[%] | To what percentage do we want to test the stopping operation | > | `Start Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Heating Start Command` \[100%] | To what percentage do we want to test the opening operation | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Cooling Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Start Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Fan Start Command` \[100%] | To what percentage do we want to test the starting operation | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `DAT Heating Arb Threshold` \[28°F] | The DAT above which there would be indication of heating | > | `Fan Current Max Threshold` \[0.2Amp] | The maximum amps threshold for a fan off status | > | `Fan Current Min Threshold` \[0.3Amp] | The minimum amps threshold for a fan on status | > > *** > [tab] Heating w/o Fan Ops > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the FCU is running.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** *Weight: 1/6* > > * Verify that *discharge temperature* is within `5△°F` \[Heating - Delta] above *mixed temperature* > > **Stop Active Cooling** *Weight: 1/6* > > * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* > > ### Test Heating > > **Test 3: Start Heating Operation** *Weight: 4/6* > > * Command Heating to `ON` > * Pass if *zone temp* raised by at least `5△°F` \[Heating - Delta] OR > * Pass if *discharge temp* is greater than `28°F` \[DAT Heating Arb Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Heating Start Command` \[100%] | To what percentage do we want to test the opening operation | > | `Start Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Stop Cooling Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Cooling Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `DAT Heating Arb Threshold` \[28°F] | The DAT above which there would be indication of heating | > | `Fan Current Max Threshold` \[0.5Amp] | The maximum threshold (Amps) for a fan off status | > | `Fan Current Min Threshold` \[1Amp] | The minimum threshold (Amps) for a fan on status | > > *** > [tab] Cooling w/ Fan Ops > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the FCU is running.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** *Weight: 4/11* > > * Verify that *discharge temperature* is within `5△°F` \[Heating - Delta] above *mixed temperature* > > **Stop Active Cooling** *Weight: 1/11* > > * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* > > ### Test the Fan > > *It must also be verified that the fan can successfully be commanded to start and stop. If either of these conditions are not verified, then the testing will be aborted.* > > **Test 1: Stop the Fan** *Weight: 1/11* > > * Command the fan to `OFF` > * Pass if *Fan Speed* is reports to be less than `5%` \[Fan Max Threshold] > > **Test 2: Start the Fan** *Weight: 1/11* > > * Command the fan to `ON` > * Pass: *Fan Percentage* >= `10%` \[Fan Min Threshold] > > ### Test Cooling > > **Test 3: Start Cooling Operation** *Weight: 4/11* > > * Command Cooling to `ON` > * Pass if *zone temp* dropped by at least `5△°F` \[Cooling - Delta] OR > * Pass if *discharge temp* is less than `19°F` \[DAT Cooling Arb Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Stop Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Fan Stop Command` \[%] | To what percentage do we want to test the stopping operation | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Stop Cooling Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Cooling Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Start Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Fan Start Command` \[100%] | To what percentage do we want to test the starting operation | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `DAT Cooling Arb Threshold` \[19°F] | The DAT below which there would be indication of cooling | > | `Fan Current Max Threshold` \[0.2Amp] | The maximum amps threshold for a fan off status | > | `Fan Current Min Threshold` \[0.3Amp] | The minimum amps threshold for a fan on status | > | `Cooling Start Command` \[100%] | To what percentage do we want to test the opening operation | > | `Start Cooling Weight` \[4] | Weight on the overall test assigned to this sequence | > > *** > [tab] Cooling w/o Fan Ops > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the FCU is running.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** *Weight: 4/9* > > * Verify that *discharge temperature* is within `5△°F` \[Heating - Delta] above *mixed temperature* > > **Stop Active Cooling** *Weight: 1/9* > > * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* > > ### Test Cooling > > **Test: Start Cooling Operation** *Weight: 4/9* > > * Command Cooling to `ON` > * Pass if *zone temp* dropped by at least `5△°F` \[Cooling - Delta] OR > * Pass if *discharge temp* is less than `16°F` \[DAT Cooling Arb Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Stop Cooling Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Cooling Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `DAT Cooling Arb Threshold` \[16°F] | The DAT below which there would be indication of cooling | > | `Fan Current Min Threshold` \[1Amp] | The minimum threshold (Amps) for a fan on status | > | `Fan Current Max Threshold` \[0.5Amp] | The maximum threshold (Amps) for a fan off status | > | `Cooling Start Command` \[100%] | To what percentage do we want to test the opening operation | > | `Start Cooling Weight` \[4] | Weight on the overall test assigned to this sequence | ## Next steps > [card] [Run a single-device test](/products/ftt/test-results#run-a-test-on-a-single-device) > > Run an on-demand FCU heating test and read the score. > [card] [VAV workflows](/products/ftt/vav-workflows) > > Explore the VAV workflow library for damper, heating, and airflow tracking tests. > [card] [AHU workflows](/products/ftt/ahu-workflows) > > Explore the AHU workflow library for damper, heating, cooling, and VFD tests. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule automated testing. # KODE glossary Source: https://docs.kodelabs.com/products/ftt/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Heat pump workflow library Source: https://docs.kodelabs.com/products/ftt/hp-workflows Reference for the heat pump functional testing workflow covering combined heating and cooling operation with fan verification. Cloud BMS provides a pre-configured heat pump (HP) functional testing workflow that tests heating and cooling in one run. The workflow commands the unit, reads discharge and mixed temperatures, and scores each sequence against thresholds. Use this page as a parameter and point-requirements lookup. For single-device practice runs, see [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). For scheduling, see [FTT projects](/products/ftt/projects). *** ## HP - Heating/cooling operation ### Testing procedure ### Pre-conditions check *Before testing is started, it must be verified that the FCU is running.* **Verify that device is `Occupied`.** > [!WARNING] > > If this condition is not met, STOP the workflow and ARCHIVE. ### Setup testing conditions *In order to ensure that testing is accurate, outside sources of heating and cooling need to be eliminated or minimized. If any of these conditions are applicable and not verified, then the testing will be aborted.* **Stop Active Heating** * Verify that *discharge temperature* is within `10△°F` \[Heating - Delta] above *mixed temperature* **Stop Active Cooling** * Verify that *discharge temperature* is within `5△°F` \[Cooling - Delta] below *mixed temperature* ### Test the Fan *It must also be verified that the fan can successfully be commanded to start and stop. If either of these conditions are not verified, then the testing will be aborted.* **Test 1: Stop the Fan** *Weight: 1/10* * Command the fan to `OFF` * Pass if *Fan Speed* is reports to be less than `5%` \[Fan Max Threshold] **Test 2: Start the Fan** *Weight: 1/10* * Command the fan to `ON` * Pass: *Fan Percentage* >= `10%` \[Fan Min Threshold] ### Test Heating **Test 3: Start Heating Operation** *Weight: 4/10* * Command Heating to `ON` * Pass if *zone temp* raised by at least `10△°F` \[Heating - Delta] OR * Pass if *discharge temp* is greater than `28°F` \[DAT Heating Arb Threshold] ### Test Cooling **Test 4: Start Cooling Operation** *Weight: 4/10* * Command Cooling to `ON` * Pass if *zone temp* dropped by at least `5△°F` \[Cooling - Delta] OR * Pass if *discharge temp* is less than `18°F` \[DAT Cooling Arb Threshold] ### Parameters | Display | Hint | | - | - | | `Stop Fan Weight` \[1] | Weight on the overall test assigned to this sequence | | `Start Heating Weight` \[4] | Weight on the overall test assigned to this sequence | | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | | `Heating Delta` \[10△°F] | The threshold tolerance for heating. Delta between MAT and DAT. | | `DAT Heating Arb Threshold` \[28°F] | The DAT above which there would be indication of heating | | `DAT Cooling Arb Threshold` \[18°F] | The DAT below which there would be indication of cooling | | `Start Fan Weight` \[1] | Weight on the overall test assigned to this sequence | | `Start Cooling Weight` \[4] | Weight on the overall test assigned to this sequence | ## Next steps > [card] [VAV workflows](/products/ftt/vav-workflows) > > Explore the VAV workflow library for damper, heating, and airflow tracking tests. > [card] [FCU workflows](/products/ftt/fcu-workflows) > > Explore the FCU workflow library for fan, heating, and cooling tests. > [card] [AHU workflows](/products/ftt/ahu-workflows) > > Explore the AHU workflow library for damper, heating, cooling, and VFD tests. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule automated testing. # What is Functional Testing? Source: https://docs.kodelabs.com/products/ftt/overview Automate equipment testing and continuous commissioning with the Cloud BMS Functional Testing Tool (FTT). The Functional Testing Tool (FTT) (Functional Testing Tool runs automated tests on HVAC equipment such as AHUs, VAVs, and FCUs.) automates the testing and validation of building equipment directly from Cloud BMS. FTT replaces manual commissioning checks with digital workflows that command equipment, monitor sensor responses, and score results automatically. Open FTT from the Cloud BMS portfolio or building sidebar. ## Example: how FTT decides if a heater works An FCU (Fan Coil Unit — terminal unit with a fan and heating/cooling coil that serves a zone or room.) heating workflow answers one question: can this unit deliver heat when commanded? The workflow runs a fixed sequence: 1. **Check readiness** — confirm the unit is occupied and the fan is running. If not, the test stops and archives. This gate is not part of the scored sequence total. 2. **Stop cooling** — close the chilled water valve. Pass when discharge air temperature rises out of a cooled range. 3. **Stop heating** — close the hot water valve. Pass when discharge air temperature falls out of a heated range. 4. **Start heating** — open the hot water valve. Pass when discharge air temperature rises past the configured threshold within the time limit. 5. **Score the run** — divide passed sequences by total scored sequences. Two of three passed is **66.67%**. In KODE Library workflows, sequences are weighted equally. Custom workflows can change sequence weight when the logic exposes a weight parameter. FTT does not rely on a visual check or a one-time site visit. It writes the commands, reads the sensors, and records pass or fail for each step. ## Why functional testing matters Traditional commissioning requires a technician to inspect each piece of equipment and verify its operation. That process is time-consuming, expensive, and usually happens once during construction. FTT shifts this to continuous, automated testing. You schedule recurring tests across your building, catch failing equipment before occupant complaints, and keep a digital record of every result. ## How the pieces fit together FTT work follows this path: 1. **Workflow (The test logic for one equipment type and component, including commands, sensors, thresholds, and report text.)** — the test logic for one equipment type and component (commands, sensors, thresholds, report text) 2. **Project (Assigns devices to a workflow, groups them by floor or count, and sets the schedule.)** — assigns devices to a workflow, groups them (by floor or count), and sets the schedule 3. **Task** — one scheduled batch inside a project (for example, Floor 03 on Monday at 16:00) 4. **Test result** — the step-by-step report and score for one device run You can also run a single on-demand test from a device without creating a project. See [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). ### Workflows A workflow defines the end-to-end test sequence for a specific equipment type and component. Each workflow specifies the points to read, the commands to write, the success criteria, and the text output for the report. Cloud BMS provides a pre-configured library covering common HVAC equipment: * **VAV (Variable Air Volume box — zone-level terminal unit that modulates airflow.)** (Variable Air Volume): damper operation, heating, airflow setpoint tracking, min/max damper * **FCU (Fan Coil Unit — terminal unit with a fan and heating/cooling coil.)** (Fan Coil Unit): heating operation, cooling operation, fan operation * **AHU (Air Handling Unit — primary airside equipment that conditions and supplies air.)** (Air Handling Unit): heating, cooling, damper operation, VFD (Variable Frequency Drive — motor controller that adjusts fan or pump speed.) operation * **Heat Pump**: heating and cooling operation You can also create custom workflows with the drag-and-drop logic builder. ![FTT workflows list showing search results for FCU heating workflows with name and description columns](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflows-list.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=e15e2a5d71203dd3b9f643af2f5a1527) The workflows list showing available testing workflows with descriptions and device types ### Projects A project assigns one or more devices to a workflow along with a schedule. Projects can span an entire building or selected floors and run over days, weeks, or months. You configure cadence, grouping, and notification recipients when you create a project. ![FTT Projects list showing columns for Project Name, Building, Workflow, Description, Schedule Type, Status, Recurrence, Start Date, and End Date with multiple V2 FCU Heating and Cooling projects](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-projects-list.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6a1001a725708a8ae249b6341663c1c1) The Projects list showing scheduled and completed testing projects across a building ### Test results Each completed test produces a report. The report shows the step-by-step sequence, sensor feedback at each stage, and a pass or fail score for each component tested. ![FTT dashboard showing Average Score 62 percent, Successfully Executed Tests 41 percent, Devices with Failures 92, Tested Device Types 1, Executed Tests 155, Tested Devices 155, Average Test Duration 9 minutes, with Workflows bar chart, Device Types donut chart, Average Score by Area bar chart, and Status gauge](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-dashboard-overview.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=f322715d673ffa947415c37618270e14) The FTT dashboard providing an at-a-glance summary of test performance ## Prerequisites FTT requires the following to produce valid results: * **Correct device templating**: all points required by the workflow must be available on the device * **Writable points (Points that accept write commands from Cloud BMS so the test can change setpoints, valves, or modes.)**: the test engine must be able to write commands and receive feedback * **Active equipment**: the device and any parent equipment (such as an upstream AHU) must be in an appropriate operating state ## Navigate to FTT **1. Open Cloud BMS** Log in to Cloud BMS and select a site from the sites list. **2. Access the FTT module** Select `FTT` from the left sidebar. The module opens to the test results dashboard. Quiz An FCU heating workflow stops during the readiness check because the unit is unoccupied, then archives. Three scored sequences never run. How should you read that result? ## Next steps > [card] [Run a single-device test](/products/ftt/test-results#run-a-test-on-a-single-device) > > Run an on-demand FCU heating test and read the score. > [card] [Test results](/products/ftt/test-results) > > Review test scores, detailed reports, and device test history. > [card] [FTT projects](/products/ftt/projects) > > Create and manage automated testing projects across your building. > [card] [Workflows](/products/ftt/workflows) > > Browse, create, and customize testing workflows. # FTT projects Source: https://docs.kodelabs.com/products/ftt/projects Create, schedule, and manage Functional Testing projects to automate equipment testing across your building in Cloud BMS. FTT projects automate testing across entire buildings, multiple floors, and extended time periods. A project assigns devices to a workflow, sets a testing schedule, and groups tasks by floor or device count for systematic execution. > [!NOTE] > > Navigate to `FTT` from the left sidebar, then select the three-dot menu at the top right and choose `Projects`. If you are new to FTT, run one on-demand test first so you know how scores are produced. See [How FTT decides pass or fail](/products/ftt/overview#example-how-ftt-decides-if-a-heater-works) and [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). ## Projects list The projects list displays all FTT projects with their status, schedule, and configuration details. ![FTT Projects list showing columns for Project Name, Building, Workflow, Description, Schedule Type, Status, Recurrence, Start Date, and End Date with multiple V2 FCU Heating and Cooling projects](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-projects-list.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6a1001a725708a8ae249b6341663c1c1) The Projects list showing all FTT projects with status, recurrence, and schedule details | Column | Description | | - | - | | `Project Name` | Name of the testing project | | `Building` | Building where the tests run | | `Workflow` | Testing workflow assigned to the project | | `Description` | Summary of the project scope | | `Schedule Type` | Whether the project runs Now or is set to Decide Later | | `Status` | Current status (Scheduled, Executed, Cancelled, Deactivated) | | `Recurrence` | Whether the project is Recurring or Once | | `Start Date` | Date and time the project begins | | `End Date` | Date and time the project ends | ## Create a project **1. Select your building** Choose the building where you want to run tests. This step completes automatically if you navigate to FTT from within a building. **2. Select a workflow and parameters** Choose the testing workflow for your project. The left panel lists all available workflows from the library. Select a workflow to view and adjust its parameters on the right. ![Create Project step 1 showing workflow list with AHU Heating Operation, AHU Mixed Damper Operation, AHU VFD Operation, AHU Cooling Operation, HP Heating Cooling Operation, V2 VAV Damper Operation, and V2 VAV Induced Heating from Library source, with Parameters panel showing Pressure Min Threshold 0.40, RAT Heating Threshold 75, Ventilation Delta 5, Cooling Delta 10, Heating Delta 10, DAT Arb Heating Threshold 85, and Reaction Time 300](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-create-project-workflow.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d09da9c684f85827ce019464e830d985) Step 1: Select a workflow from the library and adjust its parameters Each workflow includes adjustable parameters that control success criteria and time limits. Adjust these values to match your building's specific requirements. > [!NOTE] > > See the workflow library pages for detailed parameter descriptions: [VAV workflows](/products/ftt/vav-workflows), [FCU workflows](/products/ftt/fcu-workflows), [AHU workflows](/products/ftt/ahu-workflows), and [Heat pump workflows](/products/ftt/hp-workflows). **3. Select devices** Select the devices to test during the project. Use the search bar and filters to narrow devices by `Canonical Type` and `Area`. For building-wide commissioning, select all compatible devices. You can also select specific floors or individual devices. ![Create Project step 2 showing device selection table with Name, Type, Location, and Area columns, filtered by Area with 2 selected, showing 50 FCU devices across Floor 02 and Floor 03 all selected with checkboxes](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-create-project-devices.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=0eee9b1358fbf910d3b5aa83c522973f) Step 2: Select devices to include in the project with search and area filtering **4. Set the schedule** Configure when and how tests run. The schedule defines the testing cadence, grouping strategy, and recurrence pattern. ![Create Project step 3 showing Schedule Project set to Now, Group by Floor, Date 2026-05-14, Time 16:00, Test Every 1 Week on Monday, with Recurring toggle and task preview table showing Floor 02 on May 18 and Floor 03 on May 25 with 25 devices each at 16:00](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-create-project-schedule.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=494c88e4838dfd3c346644baca77f0de) Step 3: Configure the testing schedule with grouping, frequency, and task preview **Schedule project** | Option | Description | | - | - | | `Now` | Finalize the schedule immediately | | `Decide Later` | Save the workflow and parameters as a draft and set the schedule later | **Group by** | Option | Description | | - | - | | `By Floor` | Test one floor per commissioning day, working from bottom to top | | `By Count of Devices` | Test a fixed number of devices per day (such as 5, 10, or 50) | | `By None` | Include all selected devices in a single group with one testing period | > [!TIP] > > **Choose a grouping strategy** > > * Use **By Floor** when operators review results by area and you want a clear floor-by-floor cadence. > * Use **By Count of Devices** when floors are uneven or you want a fixed daily workload (for example, 10 devices per day). > * Use **By None** for a small selection, a single floor already filtered in device pick, or a one-time commissioning batch. **Date and time** Set the project start date and the time each test begins. Common configurations schedule tests during late afternoon when equipment runs at steady state. The `Date` is the earliest possible start date. `Test on Day` (for weekly cadence) is the weekday when runs are allowed. Cloud BMS schedules the first run on the first selected Test-on-Day that falls on or after the Date. For example, if `Date` is Friday, February 7 and `Test on Day` is Monday, the project does not run on February 7. It starts on the next Monday after February 7. **Test frequency** Use `Test Every` and `Test on Day` to define how often tests run. The schedule preview updates as you configure these fields. **Recurrence** Enable the `Recurring` toggle and optionally turn on `Advanced Settings` to configure repeat behavior. Simple recurrence starts the next cycle after the current cycle finishes. Advanced scheduling starts the next cycle a set time after project start or project end. The platform blocks overlapping advanced schedules. ![Schedule step with Recurring and Advanced Settings enabled, showing Repeat After set to Project is completed, Delay of 1 Week, Ends After 10 occurrences, and task preview with Floor 02 and Floor 03 showing Estimated Next Occurrence dates of Jun 01 and Jun 08 2026](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-schedule-advanced-recurrence.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=c73b7b43c5765ec58f55a603618da99a) Advanced recurrence settings with repeat timing, delay, and estimated next occurrences | Option | Description | | - | - | | `Repeat After` | Choose whether the next cycle starts after the project is completed or after the project has started | | `Delay` | Set a delay period (in weeks) between project cycles | | `Ends` | Choose `Never` for continuous testing or `After` to limit the number of recurrences | **Schedule preview** The preview table shows all scheduled tasks with their dates, device counts, and estimated next occurrences. Tasks are automatically named based on floor or group. * **Reorder tasks**: drag the handle on the left side of each row * **Edit or delete a task**: select the three-dot menu on a task row to edit its details or remove it from the schedule * **Add Task**: after you remove a device from an existing task, `Add Task` becomes available. Use it to create a new task for devices that are not in any group, then assign those devices on the Devices tab ![Schedule preview table showing Floor 02 and Floor 03 tasks with a three-dot menu expanded on Floor 03 displaying Edit and Delete options](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-schedule-task-menu.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=82969036eaa4f8f4f274a5cc5a6a7eb8) Three-dot menu on a task row with Edit and Delete options The **Edit Task** dialog lets you modify task-level settings on two tabs: * **Details**: change the task name, start date, start time, notify users, and adjust workflow parameters for this specific task ![Edit Task dialog Details tab showing Task Name Floor 02, Start Date 2026-05-18, Start Time 16:00, Notify Users and Roles dropdowns, and Parameters section with Max Sequence Duration 600, Min Sequence Duration 30, Stabilization Time 30, Chilled Water Valve Close Cmd 0, Stop Cooling DAT Threshold 70, Hot Water Valve Close Cmd 0, Stop Heating DAT Threshold 80, Hot Water Valve Open Cmd 100, and Start Heating DAT Threshold 100](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-edit-task-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4a51c95eaaaa0bd1a8e27e3669d354e9) Edit Task Details tab with task configuration and parameter overrides * **Devices**: add or remove individual devices from this task ![Edit Task dialog Devices tab showing 25 FCU devices on Floor 02 with Name, Type, Location, and Area columns, with 23 of 25 devices selected](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-edit-task-devices.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=7c8da0bf71df4e01f01e966ce810a118) Edit Task Devices tab showing device selection for a specific task **5. Add details and notify users** Complete the project configuration with a name, description, notification settings, and simultaneous test limits. ![Create Project step 4 showing Details section with Project Name FTT Project, Reason set to Routine Maintenance, auto-generated Description, Notify Users with Diellza Gashi selected, Roles with Operator/Engineer selected, Max Simultaneous Tests set to 3, and a Work Order link](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-create-project-details.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d6986d356d79d555f27c581bb5d0a858) Step 4: Configure project details, notifications, and maximum simultaneous tests **Project configuration fields** | Field | Description | | - | - | | `Project Name` | Descriptive name for the project scope, such as "Spring FCU Heating" or "Annual VAV Damper Testing" | | `Description` | Summary of the project. Select the auto-generate icon to create a description from your schedule configuration. | | `Reason` | Category for creating the project, such as "Routine Maintenance" | | `Specific Reason` | Additional detail about why the project was created | | `Notify Users` | Select specific users to notify before tests, after tests, or both | | `Notify Roles` | Select a role (such as Operator/Engineer) to notify all users in that role | | `Max Simultaneous Tests` | Number of devices tested at the same time within a single task (range: 1 to 5) | Confirm whether notifications send before tests, after tests, or both when you select users and roles. #### Work orders Select `+ Work Order` to configure automatic work order creation when testing completes. Work orders push results to an external system through the QR Connect API. ![Work Order dialog showing Name Work Order 1, Create On Completion Of set to Task, Criteria with Avg Score range 0 to 99 percent, Field Status with Operator In and Action Completed, and Configure Payload section with Data Source QR Connect API, Entity WorkOrder, and Action Create Work Order](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-work-order-config.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=bb5d883d6d11a5f1a3e079a407bd5a84) Work Order configuration with trigger, criteria, and payload settings | Field | Description | | - | - | | `Name` | Identifier for the work order rule | | `Create On Completion Of` | Trigger point: `Project`, `Task`, or `Test` | | `Avg Score` | Score range that triggers work order creation (for example, 0% to 99% to capture all non-perfect results) | | `Field / Operator / Action` | Filter conditions (for example, Status In Completed) | The **Configure Payload** section maps FTT data to your external work order system. Set the data source, entity, and action, then fill in the required fields using template variables. ![Configure Payload showing Data Source QR Connect API, Entity WorkOrder, Action Create Work Order, with fields Title FTT Project Completed, Description auto-populated, Category Smart Device, Subcategory ID Chiller Failure, Location using test.device template variable, Device Link using URL template variable, Priority Smart Device Priority, and available template variables including Task Name, Task Score, Workflow, Building, and more](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-work-order-payload.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=dad5516e5e8d1e0883ea995bcf881e01) Payload configuration mapping FTT data to external work order fields Available template variables include `Task Name`, `Task Score`, `Workflow`, `Building`, `Task Reason`, `Task - Number of Devices`, `Task Started At`, `Task Ended At`, `Task Readable Duration`, `Task Duration`, `Test Status`, `Device`, and `Area`. Select `Save` to create the project. A preview of the project and all scheduled dates appears. ## Manage existing projects Projects often run over weeks or months. As tasks complete, statuses turn green and average scores update for each task. Select a project from the list to open its details. ### Project details The **Details** tab shows all scheduled tasks with their execution history and scoring. The right panel displays project metadata including workflow, device count, completion percentage, status, description, recurrence settings, and assigned users. ![V2 FCU Heating project details showing tasks per floor with columns for Task, Scheduled Date, Last Occurrence, Number of Devices, and Average Score, plus a Details panel showing workflow V2 FCU Heating, 720 devices, 0 percent completed, Scheduled status, start date Nov 20 2025, and recurrence set to repeat when project is completed](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-project-details.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=5be4b8a6f69765950f9da739e07b3df6) Project details view showing scheduled tasks, scores, and project metadata Expand a task row to view the individual devices assigned to that task. Select one or more tasks to access bulk actions at the bottom of the page. ![Expanded Floor 03 task showing device list with Device Name and Area columns, listing FCU devices like FC\_3\_11, FC\_3\_10, FC\_3\_13 assigned to Floor 03, with Stop, Activate, Deactivate, Run and Keep Schedule action buttons at the bottom](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-project-task-devices.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=12f7133de53c4d2e5881b34445673e43) Expanded task showing individual device assignments with action buttons ### Devices tab The **Devices** tab provides a cross-project view of all device test results. A stacked bar chart shows completed, failed, and archived test counts per floor. A donut chart summarizes overall pass rates. The device table lists individual scores and allows sorting and searching. ![V2 FCU Heating Devices tab showing Executed Test Filters section with stacked bar chart of Completed, Failed, Archived, In Progress, Cancelled, and Queued counts per floor, a donut chart showing 58.2 percent, 25.32 percent, and 16.48 percent distribution, and a device table listing FC\_16\_1 at 100 percent, FC\_17\_11 at 100 percent, FC\_22\_20 at 0 percent scores](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-project-devices-tab.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=a19e6db165574e01eadc5bc3c8287b0c) Devices tab with test result charts and individual device scores ### Task actions Select one or more tasks in a project to access the following actions: | Action | Description | | - | - | | `Run & Keep` | Run the task immediately and keep the original scheduled date. The devices test twice. | | `Run` | Run the task immediately and replace the scheduled date with the current time. The task does not execute again. | | `Deactivate` | Cancel a specific task. Useful when a floor is under construction or no longer relevant. | | `Activate` | Reactivate a previously deactivated task | | `Stop` | Stop a task that is currently in progress | > [!WARNING] > > For recurring projects, task changes apply to all future iterations. Stopping or running a task persists that state across subsequent project cycles. ### Project-level actions | Action | Description | | - | - | | `Edit` | Access all configuration options. You cannot remove devices that already have test results. | | `Schedule` | Quickly adjust the testing schedule without editing the full project | | `Open Task` | Open a dedicated page to view results for a specific task | | `Last Occurrence` | View results from the most recent execution of a task | | `Devices` | View all results across the entire project with cross-filtering charts to identify failures | ## Best practices ### Align projects with heating and cooling seasons | Season | Recommended workflows | | - | - | | Spring through summer | VAV damper operation, FCU cooling | | Fall through winter | VAV induced heating, FCU heating | ### Schedule tests during optimal windows * **Weekly cadence**: creates a manageable workload for operators to review results * **Late afternoon timing**: equipment runs at steady state rather than during startup * **Low-occupancy days**: minimizes impact on occupants ### Test at scale with daily batches Testing 10 devices per day takes less than 30 minutes. Schedule daily batches at 4:00 or 5:00 PM to systematically cover the entire building. ### Use recurring projects Recurring projects enable continuous commissioning. Set up annual testing cycles aligned with heating and cooling seasons, or run year-round continuous testing. ## Next steps > [card] [Test results](/products/ftt/test-results) > > Review detailed test scores and device performance history. > [card] [Run a single-device test](/products/ftt/test-results#run-a-test-on-a-single-device) > > Practice an on-demand FCU heating run before you schedule at scale. > [card] [Workflows](/products/ftt/workflows) > > Browse and create testing workflows for your equipment. > [card] [Deployment guide](/products/ftt/deployment) > > Follow the recommended deployment strategy for calibrating and scheduling FTT. # Test results Source: https://docs.kodelabs.com/products/ftt/test-results View, filter, and analyze functional test results and detailed test reports for your building equipment in Cloud BMS. The test results page displays the output from all functional tests run across your building. Each test result contains the step-by-step sequence, sensor readings, pass or fail scores, and device test history. > [!NOTE] > > Navigate to `FTT` from the left sidebar to open the test results dashboard. Select `View all` at the top right to access the full test results list. If you have not run a test yet, review [how FTT decides pass or fail](/products/ftt/overview#example-how-ftt-decides-if-a-heater-works), then follow [Run a test on a single device](#run-a-test-on-a-single-device). ## How to read a score The score is the share of sequences that passed on that run. Two of three passed is **66.67%**. Archived precondition failures do not count as a normal failed sequence score — the run stops before the mechanical steps complete. When you open a report, read it in this order: 1. **Final score** — overall pass rate for the run 2. **Failed sequence** — which step missed its threshold 3. **Sensor reading** — measured value versus required value 4. **History** — prior scores for the same device A low score is not always a mechanical failure. Slow actuators, tight thresholds, or plant conditions can fail a sequence on healthy equipment. Use the failed sequence text to decide whether to retune parameters or investigate the unit. ## Test results dashboard The dashboard provides an at-a-glance summary of test performance across your building. ![FTT dashboard showing Average Score 62 percent, Successfully Executed Tests 41 percent, Devices with Failures 92, Tested Device Types 1, Executed Tests 155, Tested Devices 155, Average Test Duration 9 mins, with Workflows bar chart, Device Types donut chart, Average Score by Area bar chart, and Status gauge](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-dashboard-overview.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=f322715d673ffa947415c37618270e14) The FTT dashboard showing key metrics, workflow scores, device types, area breakdown, and status ### Summary metrics The top row displays key performance indicators: | Metric | Description | | - | - | | `Average Score` | Overall average score across all tests in the selected time range | | `Successfully Executed Tests` | Percentage of tests that passed | | `Devices with Failures` | Number of devices with at least one failed test | | `Tested Device Types` | Number of distinct equipment types tested | | `Executed Tests` | Total number of tests run | | `Tested Devices` | Total number of unique devices tested | | `Average Test Duration` | Average time to complete a test | ### Dashboard widgets | Widget | Description | | - | - | | `Workflows` | Stacked bar chart showing Archived, Failed, and Completed test counts per workflow with an Average Score line overlay | | `Device Types` | Donut chart showing the distribution of tests across equipment types | | `Average Score by Area` | Stacked bar chart showing test counts and average scores grouped by building area (floor) | | `Status` | Gauge chart showing the percentage breakdown of Archived, Failed, and Completed tests | ### Sequence success scores and score trend ![Sequence Success Scores stacked bar chart showing Failed and Passed counts for Pre-Condition Check, Stop Cooling, Start Heating, and Stop Heating steps, and Score Trend chart showing daily test counts with Average Score line from April 15 to April 29 2026](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-dashboard-scores-trend.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=827776a1c0adfd5e4cef5d44f68fc6ae) Sequence Success Scores per test step and Score Trend over time | Widget | Description | | - | - | | `Sequence Success Scores` | Stacked bar chart showing Failed and Passed counts for each test step (Pre-Condition Check, Stop Cooling, Start Heating, Stop Heating) | | `Score Trend` | Stacked bar chart showing daily Archived, Failed, and Completed test counts with an Average Score line overlay | ### Test times and all tests ![Test Times bubble chart showing test execution by day of week and hour, and All Tests table with Building, Area, Device Type, Device Name, Initiated By, Workflow, Start Time, End Time, Duration, and Score columns](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-dashboard-tests-table.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=37e1581199f189ec2ae3ff6b258ecfd1) Test Times bubble chart and the All Tests table with search | Widget | Description | | - | - | | `Test Times` | Bubble chart showing when tests were executed by day of week and hour. Larger bubbles indicate more tests at that time. | | `All Tests` | Searchable table listing every test result with Building, Area, Device Type, Device Name, Initiated By, Workflow, Start Time, End Time, Duration, and Score | ### Dashboard filters Use the filter toolbar to narrow dashboard data to specific criteria. ![FTT dashboard filter toolbar showing Areas, Workflows, Device Types, Statuses with 2 selected, Choose Users dropdowns, and Save and Clear All buttons](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-dashboard-filters.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5a157f0ea29e025b06e10c2a8e94d287) The dashboard filters toolbar with Areas, Workflows, Device Types, Statuses, and Users filters | Filter | Description | | - | - | | `Areas` | Filter by building areas or floors | | `Workflows` | Filter by specific testing workflows | | `Device Types` | Filter by equipment type (VAV, FCU, AHU) | | `Statuses` | Filter by test status (Completed, Failed, Archived) | | `Choose Users` | Filter by the user who initiated the test | Select `Save` to persist your filter configuration. Select `Clear All` to reset all filters. ## Test results list The test results list displays all test results in a sortable, filterable table. Use the search bar, date picker, and filters to narrow results to specific devices or time ranges. ![Tests list page showing 15 test results for device FC\_P6\_1 with columns for Building, Device Name, Type, Initiated By, Workflow, Duration, Start Time, End Time, and Score, with results ranging from 66.67 percent to 100 percent and one Archived test](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-tests-list.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2a721f0eb70616d40a04b0f47e81e25c) Tests list showing all test results for a specific device with scores, durations, and workflows | Column | Description | | - | - | | `Building` | Building where the test ran | | `Device Name` | Name of the tested device | | `Type` | Equipment type (VAV, FCU, AHU) | | `Initiated By` | Project or user that triggered the test | | `Workflow` | Testing workflow that produced the result | | `Duration` | Time the test took to complete | | `Start Time` | Date and time the test began | | `End Time` | Date and time the test finished | | `Score` | Overall test score (color-coded green for pass, red for fail) | ### Table features * **Sort columns**: select column headers with arrows to sort ascending or descending * **Customize columns**: select the column icon at the top right to show, hide, or reorder columns * **Pagination**: adjust the number of rows per page at the bottom of the table * **Search**: enter text in the search box to find matches across building, device name, device type, area, and workflow fields * **Choose Dates**: filter results to a specific date range * **Work Order**: create a work order from selected test results * **Archive Tests**: archive selected tests to exclude them from score calculations > [!NOTE] > > Archived tests are often hidden by default. Include `Archived` in the Statuses filter when you need to find them. ## Test result report Select any row in the results list to open the detailed report for that test. ### Test information The top section displays metadata about the test, including building, device name, device type, area, initiating project, workflow, start and end times, status, and duration. The right panel shows a **Work Order** section and a **History** panel with past test scores for the same device. ![V2 FCU Heating test result for device FC\_P6\_1 showing Building, Device Name, Device Type fcu, Area Parking Level 6, Initiated by V2 FCU Heating Nov 20, Workflow V2 FCU Heating, Status Completed, Duration 3 minutes, with test sequence showing Starting step with workflow description and initial conditions, Pre-Condition Check PASSED with FCU Occupancy Confirmed and Fan percent Cmd threshold check, and Work Order panel with New Work Order button and History panel showing five previous 100 percent scores](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-detail-top.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=7609a7d47fea13b6ce6062d03c62c7ef) Test result report showing device details, test sequence steps, work order panel, and score history Select `View Parameters` to see the parameter values configured for the test. Use `Prev Test` and `Next Test` to navigate between test results, or select the download icon to export the report. ### Test results detail The main section presents a step-by-step report of the testing sequence. Each sequence shows its name, duration, and pass/fail status on the left, with detailed log entries and timestamps on the right. ![Test sequence showing Stop Cooling step PASSED in 1 minute with Sequence Initialized, command to set FCU Chilled Water Valve to 0 percent with 600 second maximum and DAT must be greater than 18 success criteria, Override command successful, Collecting data for minimum 30 seconds, Success criteria met with 30 second stabilization, Cooling successfully stopped, followed by Stop Heating step PASSED in 1 minute with similar sequence commanding FCU Hot Water Valve to 0 percent with DAT must be less than 23 criteria](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-detail-sequences.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=46894bc700cffc10c09246de18a48e8b) Test sequence steps showing Stop Cooling and Stop Heating both passed ![Test sequence continuation showing Stop Heating completion with Heating successfully stopped, then Start Heating step PASSED in 1 minute with Sequence Initialized, command to set FCU Hot Water Valve to 100 percent with DAT must be greater than 20 success criteria, Override command successful, data collection, Success criteria met, Heating successfully started, and Finished step showing final Score 100 percent](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-detail-score.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=adfc6c93c2408a280cb705673d92cd25) Start Heating sequence passed and test finished with a final score of 100 percent Each sequence displays: * **Sequence description**: what the test commanded and the success criteria * **Override status**: whether the write command succeeded * **Minimum duration**: the wait time before evaluating results * **Sensor readings**: real-time point values compared against thresholds * **Stabilization period**: buffer time between sequences * **Sequence result**: pass or fail with an explanation #### Failed test example When a sequence fails, it displays a red X icon and a FAILED label. The log entries show the sensor reading that did not meet the threshold, along with the time the test waited before determining the failure. ![V2 FCU Heating test showing Starting step with workflow description and initial conditions including Occupancy Mode Occupied, Discharge Air Temp 21.1, Chilled Water Valve 0, Hot Water Valve 23.3, Fan percent Cmd 22, followed by Pre-Condition Check PASSED in less than a minute with FCU Occupancy Confirmed and Fan percent Cmd meets minimum threshold of 5, and beginning of Stop Cooling sequence](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-failed-top.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=168af8895cef8656f5775c0a527a1f72) Failed test starting sequence with initial conditions and Pre-Condition Check passed ![Stop Cooling sequence PASSED in 1 minute with FCU Chilled Water Valve commanded to 0 percent and DAT greater than 21 success criteria met, followed by Stop Heating sequence PASSED in 1 minute with FCU Hot Water Valve commanded to 0 percent and DAT less than 25 criteria met](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-failed-middle.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=86ecf83fe22a2e013c9565f6ea6dcc0c) Stop Cooling and Stop Heating sequences both passed ![Stop Heating continuation showing Heating successfully stopped, then Start Heating step FAILED after 10 minutes with FCU Hot Water Valve commanded to 100 percent, DAT must be greater than 22 criteria not met, Discharge Temp 21.2 versus Temperature Threshold 22, Heating failed to start, and Finished step showing final Score 66.67 percent with red indicators](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-failed-score.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6735b702794cd88a57b061cee571c6b3) Start Heating sequence failed with Discharge Temp 21.2 below the threshold of 22, resulting in a final score of 66.67 percent In this example, Stop Cooling and Stop Heating passed, but the Start Heating sequence failed because the discharge air temperature (21.2) did not reach the required threshold (22) within the 600-second maximum duration. The final score reflects the ratio of passed scored sequences: **66.67%** (two of three). The Pre-Condition Check passed earlier and does not change that ratio. That pattern is how FTT decides whether heating worked: command the valve, wait within the time limits, compare discharge air temperature to the threshold, then score. See [How to read a score](/products/ftt/test-results#how-to-read-a-score). ### Quick navigation The quick navigation panel on the right provides shortcuts to related test results. The **History** section shows past scores for the same device, with color-coded badges indicating pass (green) or fail (red). | Access point | Navigation shows | | - | - | | FTT landing page | Most recent tests across the portfolio | | Device details | Past tests run on the selected device | | Building page | Most recent tests for the selected building | Select any entry in the quick navigation panel to jump to that report. ### Device test history The bottom section shows historical performance for the tested device and workflow. ![Score Results line chart showing test scores over time from October 2024 to April 2026 with scores ranging from 0 to 100 percent, and Sequences Results stacked bar chart showing Failed in red and Passed in green counts per test day](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-score-sequences.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=e28a6f9816fb3efca11042e7b42c08d3) Score Results trend line and Sequences Results breakdown for a device * **Score Results**: line chart tracking test scores across multiple test runs, showing performance trends over time * **Sequences Results**: stacked bar chart showing passed (green) and failed (red) sequence counts per test execution to identify recurring failure patterns > [!TIP] > > Use the Sequences Results chart to spot persistent issues. A device that consistently fails the same sequence likely has a specific mechanical or control problem worth investigating. ### Archive a test result Select `Archive` on any test result to remove it from downstream success calculations. Archived results remain accessible but do not affect average scores or pass rates. ## Run a test on a single device You can run an FTT test immediately on a single device from the device details page without creating a project. **1. Navigate to the device** Go to `Devices` and select the device you want to test. Open the `FTT` tab on the device details page. **2. Select a workflow and reason** Select `Run New Test`. Choose a workflow from the `Workflow` dropdown and select a `Reason` for the test. Optionally add details in the `Specify` field. ![Run New Test dialog showing Workflow dropdown set to VAV ZTSS 10mins delay, Reason dropdown set to Commissioning Agent, Specify text field, Workflow Params section with Boolean set to True and Param set to 50, and Workflow Description showing testing](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-run-test-workflow.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=0a0c411e82494f6c2be266280f6ee844) Select a workflow and reason for the on-demand test **3. Review and adjust parameters (when visible)** If your role includes **View FTT Parameters for Manual Test**, review the workflow parameters and adjust values as needed for this run. Parameters vary by workflow and control success criteria, time limits, and command values. When that permission is off, the parameter fields are hidden. You can still select the workflow, set a reason, and start the test with the configured defaults. Admins assign this Write permission in Launchpad under [FTT permissions](/products/launchpad/client-organizations/apps/permissions-reference). It applies to the full parameter set for on-demand runs only, not to how creators define parameters in the workflow builder. ![Run New Test dialog showing Workflow set to V2 VAV Airflow Setpoint Tracking without AHU, Reason set to Routine Maintenance, and Workflow Params including Max Sequence Duration 300, Min Sequence Duration 30, Stabilization Time 30, Airflow SP 1 set to 0, Airflow SP 2 set to 10, and Airflow SP 3 set to 50](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-run-test-params.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=011ece60d824ab08492493ae3bc2526a) Workflow parameters for a V2 VAV Airflow Setpoint Tracking test **4. Confirm and run** Select `Continue` to review the confirmation dialog. This shows the workflow name, the device being tested, and the maximum test duration. The device is locked during the test and cannot be used until the test completes. ![Run New Test confirmation dialog asking Are you sure you want to initiate V2 VAV Airflow Setpoint Tracking without AHU for this Device with note that the device cannot be used until test is finished and maximum duration of 60 minutes, with Back and Confirm buttons](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-run-test-confirm.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=1d5df83faffa5c8314b529c65d5cf870) Confirmation dialog showing the workflow, device, and maximum test duration Select `Confirm` to start the test. The test result page opens immediately and shows live progress. **5. Monitor the test** The test result page displays the test status, sequence progress, and live log entries as the test runs. The **History** panel on the right shows previous test scores for the same device. ![V2 VAV Airflow Setpoint Tracking without AHU test result for device VAV\_204 showing Status In Progress, Duration less than a minute, Starting step with workflow description and initial conditions, Pre-Condition Check FAILED because VAV Occupancy could not be confirmed with test archived, and History panel showing previous scores of 0 percent and 100 percent](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-run-test-result.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=f1271a8e2f46ca9f8fd7ac044bde65d7) Live test result showing an in-progress test with a failed pre-condition check > [!WARNING] > > If a pre-condition check fails, the test is automatically archived. Address the pre-condition issue (such as confirming the device is in Occupied mode) before running the test again. ## Next steps > [card] [FTT introduction](/products/ftt/overview) > > Review how FTT decides pass or fail, then how workflows and projects fit together. > [card] [FTT projects](/products/ftt/projects) > > Create automated testing projects to schedule tests across your building. > [card] [Deployment guide](/products/ftt/deployment) > > Calibrate parameters and roll out recurring testing across the building. # VAV workflow library Source: https://docs.kodelabs.com/products/ftt/vav-workflows Reference for all VAV functional testing workflows including damper min/max, induced heating, airflow setpoint tracking, damper operation, heating operation, and induce heating/cooling checks. Cloud BMS provides a library of pre-configured VAV (Variable Air Volume) functional testing workflows. Each workflow commands a damper or setpoint, reads airflow or temperature response, and scores pass or fail against thresholds. Use this page as a parameter and point-requirements lookup. For the overall FTT model (workflow → project → task → score), see [What is Functional Testing?](/products/ftt/overview). For seasonal deployment, see the [Deployment guide](/products/ftt/deployment). Select a tab to open the workflow you need. *** > [tab] Damper min/max > > *This workflow will test a VAV box for its airflow when the damper is at its min and max position.* > > 1. First, we display the initial conditions of the equipment. > > 2. Then we perform precondition checks to ensure the equipment is ready to be tested. > > 3. Next we will close the damper. > > 4. Finally we will open the damper comparing to max occ cooling flow. > > > [!TIP] > > > > **Outcome:** This test will check a VAV box's ability to produce adequate min and max airflow. > > > [!TIP] > > > > **Recommended schedule:** Run weekly per floor. Run when there are comfort complaints in a space or floor. Run when new VAV boxes are installed and programmed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | VAV | Discharge Airflow, Damper Command, Min Occ Cooling Flow, Max Occ Cooling Flow | > > | AHU | Discharge Air Pressure | > > ### Preconditions > > 1. *AHU Pressure* > `Min Pressure Threshold` > > ### Variations > > * There is a variant of this workflow that will work without the AHU requirement. > * There is a variant that will work with "floating damper control" i.e. a boolean damper closed command and boolean damper open command, but in this case we cannot control to a specific close/open percent (i.e. close to 5%, open to 95%). > > ### Workflow overview > > FTT decides damper min/max performance by commanding the damper closed, then open, and comparing discharge airflow to a percentage of max occupied cooling flow. > > | Test step | Workflow | > | - | - | > | **1 Pre-condition Check** | 1. *AHU Pressure* > `Min Pressure Threshold` | > | **2 Close Damper** | 1. **Control:** Command *Damper* to `Closed` 2. **Success:** *Airflow* less than % of *Max Occ Cooling Flow* | > | **3 Open Damper** | 1. **Control:** Command *Damper* to `Open` 2. **Success:** *Airflow* greater than % of *Max Occ Cooling Flow* | > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `AHU Min Pressure` | If AHU Pressure is less than this number, the test automatically archives | > | 2 | `Damper Close Command` | What % closed do you want to command the damper? | > | 3 | `Close Damper Airflow Threshold` | What % of the Max Occ Cooling Flow do you want to set as the airflow threshold when the damper is commanded closed? | > | 4 | `Damper Open Command` | What % open do you want to command the damper? | > | 5 | `Open Damper Airflow Threshold` | What % of the Max Occ Cooling Flow do you want to set as the airflow threshold when the damper is commanded open? | > | 6 | `Max Sequence Duration` | What is the maximum length of time in seconds that a sequence should take to execute? | > | 7 | `Min Sequence Duration` | What is the minimum length of time in seconds that a sequence should take to execute? | > | 8 | `Stabilization Time` | How long in seconds should the program wait when one sequence finishes, before moving onto the next? | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Induced heating > > *This workflow will test a VAV box for its heating operation.* > > 1. First, we display the initial conditions of the equipment. > > 2. Then KODE performs precondition checks to ensure the equipment is ready to be tested. > > 3. Next we will lower the setpoint to stop heating. > > 4. Finally we will raise the setpoint to start heating. > > > [!TIP] > > > > **Outcome:** This test will check a VAV box's ability to deliver heat when its setpoint is raised. > > > [!TIP] > > > > **Recommended schedule:** Run weekly per floor. Run when there are comfort complaints in a space or floor. Run when new VAV boxes are installed and programmed. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | VAV | Occupied Mode, Discharge Air Temperature, Zone Temperature, Zone Temperature Setpoint | > > | AHU | Discharge Air Pressure | > > ### Required preconditions > > 1. *AHU Pressure* > `Min Pressure Threshold` > > ### Variations > > * There is a variant of this workflow which works with occupied heating and cooling setpoints. > * There is a variant of this workflow which works with network setpoint. > > ### Workflow overview > > | Test step | Workflow | > | - | - | > | **1 Pre-condition Check** | 1. VAV is `Occupied` 2. *AHU Pressure* > `Min Pressure Threshold` | > | **2 Stop Heating** | 1. **Control:** Lower *VAV Zone Temp Setpoint* 2. **Success:** *VAV DAT* near *AHU DAT* or *VAV Zone Temp* | > | **3 Start Heating** | 1. **Control:** Raise *VAV Zone Temp Setpoint* 2. **Success:** *VAV DAT* greater than *AHU DAT* | > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `AHU Min Pressure` | If AHU Pressure is less than this number, the test automatically archives | > | 2 | `VAV Zone Temp Setpoint Adjustment` | How far below zone temp should the setpoint be set to stop heating? How far above zone temp should the setpoint be set to start heating? | > | 3 | `VAV Stop Heating` | After lowering the VAV setpoint, the VAV DAT should approach the zone temperature. How close does the VAV DAT need to be to verify that heating has stopped? | > | 4 | `AHU Stop Heating` | After lowering the VAV setpoint, the VAV DAT should approach the AHU DAT. How close does the VAV DAT need to be to verify that heating has stopped? | > | 5 | `AHU Start Heating Temp` | After raising the VAV setpoint, the VAV DAT should rise above the AHU DAT. How much greater should the VAV DAT be than AHU DAT to verify that heating has started? | > | 6 | `Max Sequence Duration` | What is the maximum length of time in seconds that a sequence should take to execute? | > | 7 | `Min Sequence Duration` | What is the minimum length of time in seconds that a sequence should take to execute? | > | 8 | `Stabilization Time` | How long in seconds should the program wait when one sequence finishes, before moving onto the next? | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Airflow setpoint tracking > > *This workflow will test a VAV box for its ability to follow the Discharge Airflow Setpoint.* > > 1. First, you will see the equipment's preconditions. > > 2. Then, KODE runs a precondition check (verification process) to confirm the equipment is ready for testing. > > 3. Finally, KODE adjusts the setpoints and monitors discharge airflow to determine if the VAV achieves the intended setpoint. > > > [!TIP] > > > > **Outcome:** This test will identify issues with a VAV's ability to follow airflow. > > > [!TIP] > > > > **Recommended schedule:** Run weekly per floor. > > > [!NOTE] > > > > **Point requirements:** > > > > | Device | Required points | > > | - | - | > > | VAV | Occupied Mode, Discharge Airflow, Discharge Airflow Setpoint, Min Occ Cooling Flow, Max Occ Cooling Flow | > > | AHU | Discharge Air Pressure | > > ### Workflow overview > > | Test step | Workflow | > | - | - | > | **1 Pre-condition Check** | 1. VAV is `Occupied` 2. *AHU Pressure* > `Min Pressure Threshold` | > | **2 Airflow SP - 1** | 1. **Control:** Command *Airflow Setpoint* 2. **Success:** *Airflow* in range of setpoint +/- tolerance | > | **3 Airflow SP - 2** | 1. **Control:** Command *Airflow Setpoint* 2. **Success:** *Airflow* in range of setpoint +/- tolerance | > | **4 Airflow SP - 3** | 1. **Control:** Command *Airflow Setpoint* 2. **Success:** *Airflow* in range of setpoint +/- tolerance | > | **5 Airflow SP - 4** | 1. **Control:** Command *Airflow Setpoint* 2. **Success:** *Airflow* in range of setpoint +/- tolerance | > > **Variations:** There is a variant of this workflow that will work without the AHU requirement. > > ### Tuning parameters > > | # | Parameter | Description | > | - | - | - | > | 1 | `AHU Min Pressure` | If AHU Pressure is less than this number, the test automatically archives | > | 2 | `Airflow SP - 1` | What % of the Max Occ Cooling Flow do you want to set as the first target? | > | 3 | `Airflow SP - 2` | What % of the Max Occ Cooling Flow do you want to set as the second target? | > | 4 | `Airflow SP - 3` | What % of the Max Occ Cooling Flow do you want to set as the third target? | > | 5 | `Airflow SP - 4` | What % of the Max Occ Cooling Flow do you want to set as the fourth target? | > | 6 | `SP Tolerance %` | How close should the airflow be to the airflow setpoint to pass? | > | 7 | `Max Sequence Duration` | What is the maximum length of time in seconds that a sequence should take to execute? | > | 8 | `Min Sequence Duration` | What is the minimum length of time in seconds that a sequence should take to execute? | > | 9 | `Stabilization Time` | How long in seconds should the program wait when one sequence finishes, before moving onto the next? | > > ### Common reasons for unsuccessful tests > > | # | Reason | Description | > | - | - | - | > | 1 | **Check and Adjust Calibration** | Begin by verifying the calibration of all sensors involved in the test, especially the discharge airflow sensors and pressure transducers in the AHU. Calibration issues can lead to inaccurate readings that cause the system to deviate from the setpoint. If any sensors are found to be out of calibration, recalibrate them according to the manufacturer's specifications before rerunning the test. | > | 2 | **Inspect VAV and AHU Components** | Examine the physical condition of the VAV box and associated AHU components. Check for any signs of damage or wear that could affect performance, such as stuck dampers, leaks in the ducts, or malfunctioning actuators. If any issues are found, perform the necessary repairs or replacements. Ensure all components are clean and free from obstructions that could impair airflow. | > | 3 | **Review System Configuration and Sequencing** | Evaluate the VAV box programming and configuration settings. Confirm that the airflow setpoints, sequence durations, and stabilization times are correctly set according to the operational requirements. Adjust the control sequences if needed to ensure they align with the current operational strategy and performance expectations. It may also be helpful to consult with a control specialist to optimize the sequence of operations for better performance. | > > > [!NOTE] > > > > If you need assistance with interpreting your results, reach out to the support team at [support@kodelabs.com](mailto:support@kodelabs.com). > > *** > [tab] Damper operation > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the VAV is in operation.* > > **Verify that VAV is `Occupied`.** > > **Verify that its parent AHU is `Occupied`.** > > **Verify fan is running** by checking that *duct pressure* is more than `0.4psi` \[Pressure Min Threshold] > > > [!WARNING] > > > > If any of these conditions are not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, sources of heating must be eliminated or minimized. If this condition is applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** > > * Verify that *discharge temp* drops to `10△°F` \[Heating AHU - Delta] below original *discharge temp* AND > * Verify that *zone temp* is less than `5△°F` \[Heating - Delta] above *discharge temp* > > ### Damper testing > > **Close the Damper** > > * Command *Damper* to `CLOSED` > * Pass if *VAV discharge flow* is less than `30cfm` \[Max Allowed Flow] > > **Open the Damper** > > * Command *Damper* to `OPEN` > * Pass if *discharge airflow* is greater than `100cfm` \[Min Flow Indication] OR > * Pass if *discharge airflow* is `20%` \[Relative Flow Tolerance] greater than *discharge airflow setpoint* > > ### Parameters > > | Display | Hint | > | - | - | > | `Damper Close Command` \[%] | To what percentage do we want to test the closing operation | > | `Close Damper Weight` \[2] | Weight on the overall test assigned to this sequence | > | `Damper Open Command` \[100%] | To what percentage do we want to test the opening operation | > | `Open Damper Weight` \[2] | Weight on the overall test assigned to this sequence | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Pressure Min Threshold` \[0.4psi] | How much should the duct pressure be minimally | > | `Heating AHU Delta` \[10△°F] | The threshold tolerance for heating. Delta (DAT VAV - DAT AHU). | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `Max Allowed Flow` \[30cfm] | Max allowed Flow when fully closed damper | > | `Min Flow Indication` \[100cfm] | Minimum Flow to indicate open damper | > | `Relative Flow Tolerance` \[20%] | How much below the setpoint in % do we allow the flow to be when we have a fully open damper | > | `Reaction Time` \[300sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `AHU Fan Min Threshold` \[5%] | How much should the AHU discharge fan be minimally in percentage | > > *** > [tab] Heating operation > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the VAV is in operation.* > > **Verify that VAV is `Occupied`.** > > **Verify that its parent AHU is `Occupied`.** > > **Verify fan is running** by checking that *duct pressure* is more than `0.4psi` \[Pressure Min Threshold] > > > [!WARNING] > > > > If any of these conditions are not met, STOP the workflow and ARCHIVE. > > ### Setup testing conditions > > *In order to ensure that testing is accurate, sources of heating must be eliminated or minimized. If this condition is applicable and not verified, then the testing will be aborted.* > > **Stop Active Heating** > > * Verify that *discharge temp* drops to `10△°F` \[Heating AHU - Delta] below original *discharge temp* AND > * Verify that *zone temp* is less than `5△°F` \[Heating - Delta] above *discharge temp* > > ### Damper testing > > **Close the Damper** > > * Command *Damper* to `CLOSED` > * Pass if *VAV discharge flow* is less than `30cfm` \[Max Allowed Flow] > > **Open the Damper** > > * Command *Damper* to `OPEN` > * Pass if *discharge airflow* is greater than `100cfm` \[Min Flow Indication] OR > * Pass if *discharge airflow* is `20%` \[Relative Flow Tolerance] greater than *discharge airflow setpoint* > > ### Test Heating > > **Start Heating** > > * Verify that *discharge temp* rises to `10△°F` \[Heating AHU - Delta] above original *discharge temp* AND > * Verify that *zone temp* is greater than `5△°F` \[Heating - Delta] above *discharge temp* > > ### Parameters > > | Display | Hint | > | - | - | > | `Damper Close Command` \[%] | To what percentage do we want to test the closing operation | > | `Close Damper Weight` \[2] | Weight on the overall test assigned to this sequence | > | `Damper Open Command` \[100%] | To what percentage do we want to test the opening operation | > | `Open Damper Weight` \[2] | Weight on the overall test assigned to this sequence | > | `Heating Stop Command` \[%] | To what percentage do we want to test the closing operation | > | `Stop Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Pressure Min Threshold` \[0.4psi] | How much should the duct pressure be minimally | > | `Heating AHU Delta` \[10△°F] | The threshold tolerance for heating. Delta (DAT VAV - DAT AHU). | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `Max Allowed Flow` \[30cfm] | Max allowed Flow when fully closed damper | > | `Min Flow Indication` \[100cfm] | Minimum Flow to indicate open damper | > | `Relative Flow Tolerance` \[20%] | How much below the setpoint in % do we allow the flow to be when we have a fully open damper | > | `Reaction Time` \[300sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `AHU Fan Min Threshold` \[5%] | How much should the AHU discharge fan be minimally in percentage | > | `DAT Heating Threshold` \[70°F] | How much should the DAT maximally be for our VAV to be able to provide reheat | > | `Sec Loop Valve Req` \[10%] | How much should the Valve minimally be in (%) to run the heating test | > | `Heating Start Command` \[100%] | To what percentage do we want to test the opening operation | > | `Start Heating Weight` \[4] | Weight on the overall test assigned to this sequence | > > *** > [tab] Induce heat/cool feedback > > ### Testing procedure > > ### Pre-conditions check > > *Before testing is started, it must be verified that the unit is in operation.* > > **Verify that device is `Occupied`.** > > > [!WARNING] > > > > If this condition is not met, STOP the workflow and ARCHIVE. > > ### Test the Fan > > **Test 1: Stop the Fan** *Weight: 1/10* > > * Command the fan to `OFF` > * Pass if *Fan Speed* is reports to be less than `5%` \[Fan Max Threshold] > > **Test 2: Start the Fan** *Weight: 1/10* > > * Command the fan to `ON` > > * Pass: *Fan Percentage* >= `10%` \[Fan Min Threshold] > > > [!WARNING] > > > > If Test 1 or Test 2 FAIL, STOP the workflow. > > ### Test Heating > > *There are two methods available to verify successful heating operation. You can use a static setpoint (`DAT Heating Arb Threshold`) that the discharge temperature must reach, or you can set a minimum change in temperature (`Heating - Delta`) to validate heating had occurred.* > > *Use the boolean parameter, `Arb Setpoint`, to choose the method, with the default (False) indicating the use of the delta for verification.* > > **Test 3: Start Heating Operation** *Weight: 4/10* > > If `Arb Setpoint` \[False]: > > * Command *zone temp setpoint* to `5△°F` \[Delta Setpoint] above the *zone temp* sensor reading > * Pass if *Discharge Air* is `5△°F` \[Heating - Delta] greater than the *zone temperature* sensor reading > > Otherwise if `Arb Setpoint` is True: > > * Command *zone temp setpoint* to `80°F` \[Arb Heating Setpoint] > * Pass if *Discharge Air* is less than `28°F` \[DAT Heating Arb Threshold] > > ### Test Cooling > > **Test 4: Start Cooling Operation** *Weight: 4/10* > > If `Arb Setpoint` \[False]: > > * Command *Zone Temp Setpoint* to `5△°F` \[Delta Setpoint] less than *Zone Temp* > * Pass if *Discharge Air* is `5△°F` \[Cooling - Delta] less than *Zone Temp* > > Otherwise if `Arb Setpoint` is True: > > * Command *Zone Temp Setpoint* to `65°F` \[Arb Cooling Setpoint] > * Pass if *Discharge Air* is less than `18°F` \[DAT Cooling Arb Threshold] > > ### Parameters > > | Display | Hint | > | - | - | > | `Stop Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Heating Operation Weight` \[4] | Weight on the overall test assigned to this sequence | > | `Cooling Delta` \[5△°F] | The threshold tolerance for cooling. Delta between ZT and DAT. | > | `Fan Max Threshold` \[5%] | The maximum threshold (%) for a fan off status | > | `Fan Min Threshold` \[10%] | The minimum threshold (%) for a fan on status | > | `Reaction Time` \[240sec] | How long to wait for the actuators to fully do their job | > | `Stabilization Time` \[60sec] | How long to wait for the system to come to stability after an actuator command and the conditions have been fulfilled | > | `Measure After` \[60sec] | How long to wait in seconds to start checking the feedback readings | > | `Heating Delta` \[5△°F] | The threshold tolerance for heating. Delta between ZT and DAT. | > | `DAT Cooling Arb Threshold` \[18°F] | The DAT below which there would be indication of cooling | > | `DAT Heating Arb Threshold` \[28°F] | The DAT above which there would be indication of heating | > | `Arb Setpoint` \[False] | If true, will use "Arbitrary Setpoint" for the new Temp Setpoint | > | `Arb Cooling Setpoint` \[65°F] | Setpoint to induce cooling mode | > | `Arb Heating Setpoint` \[80°F] | Setpoint to induce heating mode | > | `Delta Setpoint` \[5△°F] | Delta above which we want to induce cooling/heating mode | > | `Start Fan Weight` \[1] | Weight on the overall test assigned to this sequence | > | `Cooling Operation Weight` \[4] | Weight on the overall test assigned to this sequence | > > ### Related workflows > > > [!NOTE] > > > > **VAV/FCU - Induce heating and check for feedback:** Tests heating only (no cooling sequence). Uses the same parameters and verification methods. Weight distribution: Stop Fan 1/6, Start Fan 1/6, Heating Operation 4/6. > > > [!NOTE] > > > > **VAV/FCU - Induce cooling and check for feedback:** Tests cooling only (no heating sequence). Fan is checked but not commanded. Weight distribution: Stop Fan 1/5, Cooling Operation 4/5. ## Next steps > [card] [Deployment guide](/products/ftt/deployment) > > Calibrate parameters and schedule seasonal VAV testing. > [card] [FCU workflows](/products/ftt/fcu-workflows) > > Explore the FCU workflow library for fan, heating, and cooling tests. > [card] [AHU workflows](/products/ftt/ahu-workflows) > > Explore the AHU workflow library for damper, heating, cooling, and VFD tests. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule automated testing. # Workflow creator guide Source: https://docs.kodelabs.com/products/ftt/workflow-creator-guide Build custom FTT workflows when the library does not match your sequence of operations. This guide is for building **custom** FTT workflows after you understand how library tests score equipment. You design the conceptual test, classify inputs and outputs, build logic in the workflow builder, construct report text, and validate with the debugger. If you are new to FTT, start with [What is Functional Testing?](/products/ftt/overview) and [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). Most sites deploy library workflows first. Use this guide when a library workflow does not match your sequence of operations. > [!NOTE] > > Before you create a custom workflow, review [Workflow logic blocks](/products/ftt/workflow-logic-blocks) for available block types. ## When to build a custom workflow Use the library when a standard VAV, FCU, AHU, or heat pump workflow already matches the component you need to score. Build a custom workflow when you need a different command path, sensor set, or success criteria. Common situations that lead to custom work: * Continuous commissioning at scale for terminal units across heating and cooling seasons * Retail or multi-site validation before and after a service visit * New construction prioritization so agents re-test failed units instead of spot-checking a small sample ## Workflow architecture Every workflow in the KODE standard architecture contains the following components: | Component | Description | | - | - | | **Device type** | Equipment type the workflow tests (VAV, FCU, AHU) | | **Sensor inputs** | Points that read from the device to indicate operating conditions | | **Required states** | Conditions that must be met before testing begins | | **Parameters** | User-adjustable values that control success criteria and time limits | | **Initial condition logic** | Prints the starting state of the equipment | | **Pre-condition logic** | Verifies the equipment is in a suitable state for testing | | **Sequence logic** | Commands equipment and evaluates pass or fail results | | **Release** | Ends the test and releases all overrides | ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR SI["Sensor
      Inputs"]:::Lavender RS["Required
      States"]:::Mint P["Parameters"]:::Lavender IC["Initial
      Conditions"]:::Navy PC["Pre-condition
      Check"]:::Navy S1["Sequence 1"]:::Lavender S2["Sequence 2"]:::Lavender REL["Release"]:::Mint SI --> IC IC -.-> PC RS --> PC PC --> S1 S1 --> S2 S2 --> REL P --> S1 P --> S2 linkStyle 0,1,2,3,4,5 stroke:#374D7C linkStyle 6,7 stroke:#7B68AE classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Mint stroke-width:1px, stroke:#5CA87C, fill:#D0F0DB, color:#2D6B4E ``` ### Time control parameters KODE standard architecture uses three time control parameters in every workflow. These are user-adjustable and applied consistently to each sequence. | Parameter | Description | Units | | - | - | - | | `Min Sequence Duration` | Minimum duration of each sequence, giving the equipment time to respond to the command | Seconds | | `Max Sequence Duration` | Maximum duration of each sequence. If the equipment does not reach success criteria within this time, the sequence fails. | Seconds | | `Stabilization Time` | Buffer time between moving from one sequence to the next | Seconds | ## Sequence architecture Sequences are the core building blocks of a workflow. Each sequence tests one mechanical component by issuing a command, monitoring the sensor response, and scoring the result. Sequences are isolated to the smallest individual component of the device that you want to test and score. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR T["Trigger"]:::Mint CV["Cmd Value"]:::Lavender WC["Write Cmd"]:::Navy PSI["Primary
      Sensor Input"]:::Lavender BT["Base
      Threshold"]:::Lavender CP["Calc
      Parameter"]:::Lavender CL["Calculation
      Logic"]:::Navy COMP["Comparison"]:::Rose SO["Sequence
      Output"]:::Mint TC["Time Control"]:::Navy MSG["String Builder
      Messages"]:::Orange T --> WC CV --> WC WC -.-> MSG PSI --> COMP BT --> CL CP --> CL CL --> COMP COMP --> SO COMP -.-> TC COMP -.-> MSG linkStyle 0,1,3,4,5,6,7 stroke:#374D7C linkStyle 2,8,9 stroke:#E67E22 classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Mint stroke-width:1px, stroke:#5CA87C, fill:#D0F0DB, color:#2D6B4E classDef Rose stroke-width:1px, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Orange stroke-width:1px, stroke:#E67E22, fill:#FDEBD0, color:#935116 ``` ### Components of a sequence | Component | Description | Example | | - | - | - | | **Trigger** | Logical input that starts the sequence | Start signal from previous sequence | | **Write command** | Point override issued to the equipment | VAV Damper Command | | **Command value** | Specific value written via the command | 0% (close) or 100% (open) | | **Primary sensor input** | Response variable compared against the threshold | VAV Discharge Airflow | | **Base threshold** | Reference value for calculating the success criteria | Max Occupied Cooling Flow | | **Calculation parameter** | User-adjustable modifier applied to the base threshold | 10% | | **Calculation logic** | Operation between base threshold and parameter | Multiplication | | **Calculated threshold** | Final value the sensor must reach to pass | 10% of Max Occupied Cooling Flow | | **Comparison** | How the sensor is compared to the threshold | Less than or equal | ### Sequence string builders Each sequence generates six messages in the test report: | Message | Description | | - | - | | **Sequence description** | What is being commanded, the time limit, the success criteria, and how thresholds were calculated | | **Command success/failure** | Whether the write command to the equipment succeeded | | **Minimum duration** | The minimum wait time before evaluating the sequence | | **Sensor reading** | Real-time sensor value and required threshold (updates repeatedly) | | **Stabilization** | Buffer time after the sequence passes or fails | | **Sequence success/failure** | Final pass or fail result for the sequence | ![Close Damper sequence output showing message 1 Sequence Description explaining the command and success criteria, messages 2 and 3 Override Command Successful with feedback check after 10 seconds, message 4 Sensor Reading showing Discharge Airflow values approaching the threshold, message 5 Operation Successful with stabilization wait, and message 6 Damper Commanded closed and Flow was not detected](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-sequence-output-messages.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=bed911838f2f2802f5a851a2fa2de706) A test result showing the six output messages generated per sequence, numbered 1 through 6 ## Step 1: conceptual design Define each sequence, write command, and success criteria before opening the logic builder. This section uses VAV Damper Operation as a working example. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart TB subgraph PC["Pre-condition Check"] direction TB P1["VAV Occupancy"]:::Navy P2["AHU Occupancy"]:::Navy P3["AHU Pressure"]:::Navy end subgraph CD["Close Damper"] direction TB C1["Control: damper closed"]:::Lavender C2["Success if airflow ≤ 10%\nof max occ cooling flow"]:::Lavender end subgraph OD["Open Damper"] direction TB O1["Control: damper open"]:::Mint O2["Success if airflow ≥ 90%\nof max occ cooling flow"]:::Mint end PC -- "pass" --> CD -- "pass" --> OD linkStyle 0,1 stroke:#374D7C,stroke-width:2px style PC fill:#B8D4E8, stroke:#374D7C, color:#374D7C, stroke-width:2px style CD fill:#E2E0F0, stroke:#9B8EC4, color:#4A3780, stroke-width:2px style OD fill:#D0F0DB, stroke:#5CA87C, color:#2D6B4E, stroke-width:2px classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Mint fill:#D0F0DB, color:#2D6B4E, stroke:#5CA87C, stroke-width:1px ``` **1. Define pre-condition checks** Identify the states the equipment must be in for a valid test. Ask: what conditions ensure the test produces a meaningful mechanical result? | Sensor value | Requirement | Type | | - | - | - | | `VAV Occupancy` | Occupied | State check | | `AHU Occupancy` | Occupied | State check | | `AHU Pressure` | `AHU Min Pressure Threshold` | Threshold check | **2. Define each sequence** For each mechanical component to test, specify the write command, sensor input, threshold calculation, and comparison type. **Sequence 1: Close damper** | Component | Value | Type | | - | - | - | | Write command | VAV Damper Command | Workflow design | | Command value | 0% | User input | | Primary sensor input | VAV Discharge Airflow | Sensor input | | Base threshold | Max Occupied Cooling Flow | Sensor input | | Calculation parameter | 10% | User input | | Calculation logic | Multiplication | Workflow design | | Calculated threshold | 10% of Max Occ Cooling Flow | Calculated | | Comparison | Less than or equal | Workflow design | **Sequence 2: Open damper** | Component | Value | Type | | - | - | - | | Write command | VAV Damper Command | Workflow design | | Command value | 100% | User input | | Primary sensor input | VAV Discharge Airflow | Sensor input | | Base threshold | Max Occupied Cooling Flow | Sensor input | | Calculation parameter | 90% | User input | | Calculation logic | Multiplication | Workflow design | | Calculated threshold | 90% of Max Occ Cooling Flow | Calculated | | Comparison | Greater than or equal | Workflow design | **3. Classify all inputs** Organize every point and value into four categories. This determines which logic block type to use in the builder. | Sensor inputs | Required states | Parameters | Write commands | | - | - | - | - | | AHU Occupancy | AHU Occupied | Max Sequence Duration | VAV Damper Close Cmd | | AHU Pressure | VAV Occupied | Min Sequence Duration | VAV Damper Open Cmd | | VAV Occupancy | | Stabilization Time | | | VAV Discharge Airflow | | AHU Min Pressure | | | VAV Max Occ Cooling Flow | | Close Cmd | | | | | Lower Bound - Airflow Multiplier | | | | | Open Cmd | | | | | Upper Bound - Airflow Multiplier | | ## Step 2: build the workflow **1. Set up the main folder** Create the workflow and populate the main folder with sub-folders for device types, required states, and parameters. Add read blocks, parameter blocks, and write commands to their respective folders. The write commands are used later inside specific sequences. ![Logic builder showing the main folder with VAV device block containing Occ Mode, Damper Position, Discharge Airflow, and Max Occ Cooling Flow outputs, AHU device block with Occ Mode and DAP, Required States block with AHU Occupied and VAV Occupied, and Parameters block with Max Sequence Duration, Min Sequence Duration, Stabilization Time, AHU Pressure Min Threshold, Close Damper Command, Lower Bound Airflow, Open Damper Command, and Upper Bound Airflow](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-builder-step1-main-folder.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=1903a6c80a9a1fd68d47c915067a9b09) Step 1: Main folder populated with VAV, AHU, Required States, and Parameters sub-folders **2. Build the high-level structure** Create folders for initial conditions, pre-condition checks, and each control sequence. Connect the main inputs and outputs to form the overall workflow structure. ![Logic builder showing Step 2 Workflow Structure with AHU and VAV device blocks, Required States, and Parameters connected to an Initial Conditions folder with print outputs, a Pre-Conditions Check folder with trigger and check result, and two Sequence folders each with Trigger, Primary Point, Base Threshold, Calc Point, Write Cmd, Min Duration, Max Duration, and Stabilization Time inputs](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-builder-step2-structure.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=57a5ccc2b7a0385c8005edd294ef8dc7) Step 2: High-level workflow structure with initial conditions, pre-condition check, and sequence folders **3. Connect points to folders** Connect your sensor inputs, required states, parameters, and write commands into the appropriate folders. This completes the high-level wiring of the workflow. ![Logic builder showing Step 3 Connected Workflows with all VAV, AHU, Required States, and Parameters blocks fully wired into Initial Conditions, Pre-Conditions Check, Sequence 1 and Sequence 2 folders with connection lines visible between all inputs and outputs](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-builder-step3-connected.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=910ca9b19263b2d3741d01caaaa020da) Step 3: All points connected from the main folder into the workflow structure **4. Build each sequence** Open each sequence folder and configure the logic blocks. For each control sequence, ask: * Am I writing the correct point field? * Am I doing the proper calculation on my base threshold (multiplication, addition, subtraction)? * Am I doing the proper comparison (less than, greater than, equal to)? ![Logic builder showing Step 4 Sequence Logic inside Sequence 1 with Input blocks for Trigger, Write Cmd, Primary Point, Base Threshold, and Calc Point connected through Product calculation and comparison logic to Number Switch and String Switch outputs, with timing blocks for Min Duration, Max Duration, and Stabilization Time, and String Builder blocks for sequence description, sensor reading, and result messages](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-builder-step4-sequence-logic.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5ddbd8b6a1fa41ce946f492b9d73577d) Step 4: Inside Sequence 1 showing the complete logic with write command, threshold calculation, comparison, timing, and string builders ## Step 3: build text output Use string builder blocks to combine static text with variable inputs from the logic. The command success/failure, minimum duration, and stabilization messages are standard and generally do not require modification. Focus on customizing the three messages below. > [!NOTE] > > In the templates below, *italic text* represents static text you should customize for your test. `Backtick text` represents dynamic values populated by drawing lines from logic blocks into the string builder. ### Sequence description message This message describes the command being issued, the maximum time duration, the success criteria, and how the thresholds were calculated. Template: 1. This sequence will command the *VAV Damper Cmd* to 2. `Command Value` 3. %. The equipment has a maximum of 4. `Max Duration` 5. seconds to achieve the success criteria. 6. In order to succeed the 7. *VAV Airflow must be less than* 8. `Calculated Threshold` 9. . The threshold of 10. `Calculated Threshold` 11. was calculated by taking: 12. `Parameter Calc` 13. *% of the Max Occ Cooling Flow.* ![String Builder block showing alternating rows of static text like This sequence will command and variable input slots like 2nd Word, 4th Word, 7th Word, 9th Word, and 11th Word that receive values from logic block connections](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-string-builder-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2c00568c4a24461f0f1faa75abbfc52e) A String Builder block configured for the sequence description with alternating static text and variable inputs from logic blocks ### Sensor reading message This message outputs repeatedly during the sequence each time a new point value is received. It displays the measured value and the required threshold. Template: 1. *Discharge Airflow*: 2. `Primary Sensor Input` 3. *Threshold 1*: 4. `Calculated Threshold 1` ### Sequence success/failure message This message outputs at the end of the sequence to confirm the result. Modify the text directly to match your test. * Success: *"Damper successfully closed."* * Failure: *"Damper failed to close."* ### Initial conditions string builder The initial conditions section prints the overall workflow description and the starting values of each point per device. **Workflow description template:** This workflow will test a *VAV box* for its *damper operation*. First, we display the initial conditions of the equipment, then we perform pre-condition checks to ensure the equipment is ready to be tested, next we will *close the damper* and then *open the damper* measuring *airflow* to validate the operation. **Device initial conditions template:** 1. *Device Type*: 2. *Point Name 1* - 3. `Point Value 1` 4. *Point Name 2* - 5. `Point Value 2` ### Pre-conditions check string builder Pre-condition checks come in two forms, each requiring a success and failure message. **State check:** Success: 1. `Device Type` 2. *is* 3. `Required State` 4. *and passes the pre-condition check.* Failure: 1. `Device Type` 2. *is not* 3. `Required State` 4. *and fails the pre-condition check.* **Threshold check:** Success: 1. `Device Type` 2. *Airflow/Pressure/Temperature does meet the maximum threshold.* 3. *Sensor:* 4. `Point Value` 5. *. Min/Max Threshold:* 6. `Parameter` Failure: 1. `Device Type` 2. *Airflow/Pressure/Temperature does not meet the minimum threshold.* 3. *Sensor:* 4. `Point Value` 5. *. Min/Max Threshold:* 6. `Parameter` ## Step 4: quality assurance Use the debugger to validate each section of the workflow. Open the `Debugger` tab, review and adjust parameter values, then select `Start Simulation`. ![Debugger tab showing PARAMS panel with FCU Fan Cmd percent Low Limit, Loop Differential Pressure Low Limit, Max Sequence Duration, Min Sequence Duration, Stabilization Time, Chilled Water Valve Close Cmd, and Stop Cooling DAT Threshold parameters](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-debugger-params.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=a0cc19e40522d6c9e252e1c1095cec95) The debugger PARAMS panel where you set parameter values before running a simulation ### Initial conditions For each device type, verify: 1. The correct device type prints 2. The correct point names print 3. The correct point values print ### Pre-condition checks For each check, test both the success and failure case. Update `INPUT` values in the debugger to simulate different equipment conditions. ![Debugger showing INPUTS panel with Differential Pressure, Occ Mode, Fan percent Cmd, Chilled Water Valve Cmd, and DAT fields with status dropdowns set to ok, while the simulator shows Pre-Condition Check sequence initialized](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-debugger-inputs.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=4858378c5694962a43dfcee9c06bd345) The INPUTS panel during simulation where you send sensor values to test workflow responses Using the VAV Damper Operation example with three pre-condition checks: | Pre-condition | Test success | Test failure | | - | - | - | | **VAV Occupancy** | Input an occupied value and verify the correct success statement prints | Input an unoccupied value and verify the correct failure statement prints | | **AHU Occupancy** | Input an occupied value and verify the correct success statement prints | Input an unoccupied value and verify the correct failure statement prints | | **AHU Pressure above Threshold** | Input a pressure above the threshold and verify the correct success statement prints | Input a pressure below the threshold and verify the correct failure statement prints | ### Control sequences For each sequence, verify: 1. The threshold calculation is correct 2. The sequence passes when the sensor reaches the threshold 3. The sequence fails when values approach but do not reach the threshold 4. The string builders produce consistent description and sensor reading messages Compare the debugger output with what a real test result looks like. The sequence names, descriptions, and pass/fail messages should match. ![V2 FCU Heating test result showing Starting step with workflow description and initial conditions, Pre-Condition Check PASSED with FCU Occupancy Confirmed and Fan percent Cmd threshold check](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-test-detail-top.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=7609a7d47fea13b6ce6062d03c62c7ef) A real test result showing the output format your workflow should produce > [!TIP] > > Delay times run in real time during simulation. Temporarily change time units to seconds on timer blocks to speed up testing. Return to the correct units before deploying. ## Scaling to complex use cases The standard architecture extends to handle advanced scenarios. These patterns can be combined within a single sequence as needed. ### Multiple write commands in a single sequence Issue commands to multiple points within a single sequence, such as commanding both a damper and a fan. Connect both write commands through an AND block before proceeding to the comparison logic. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR T["Trigger"]:::Mint WC1["Write Cmd 1"]:::Navy WC2["Write Cmd 2"]:::Navy AND["AND"]:::Mint S1["Sensor 1"]:::Lavender BT["Base Threshold 1"]:::Lavender CP["Calc Parameter 1"]:::Lavender CL["Calculation
      Logic"]:::Navy COMP["Comparison"]:::Rose SO["Sequence
      Output"]:::Mint TC["Time Control"]:::Navy T -.-> WC1 T -.-> WC2 WC1 --> AND WC2 --> AND S1 --> COMP BT --> CL CP --> CL CL --> COMP AND --> COMP COMP --> SO COMP -.-> TC linkStyle 0,1,2,3,4,5,6,7,8,9 stroke:#374D7C linkStyle 10 stroke:#374D7C classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Mint stroke-width:1px, stroke:#5CA87C, fill:#D0F0DB, color:#2D6B4E classDef Rose stroke-width:1px, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 ``` ### Calculated command values Derive the command value from sensor data or parameters rather than using a fixed value. Add a Calculation Logic block between the command parameter and the write command. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR T["Trigger"]:::Mint BCV["Base Cmd
      Value"]:::Lavender CCP["Cmd Calc
      Param 1"]:::Rose CL1["Calculation
      Logic"]:::Navy WC["Write Cmd 1"]:::Navy S1["Sensor 1"]:::Lavender BT["Base
      Threshold 1"]:::Lavender CP["Calc
      Parameter 1"]:::Lavender CL2["Calculation
      Logic"]:::Navy COMP["Comparison"]:::Rose SO["Sequence
      Output"]:::Mint TC["Time Control"]:::Navy T -.-> WC BCV --> CL1 CCP --> CL1 CL1 --> WC S1 --> COMP BT --> CL2 CP --> CL2 CL2 --> COMP COMP --> SO COMP -.-> TC linkStyle 0,1,2,3,4,5,6,7,8 stroke:#374D7C linkStyle 9 stroke:#374D7C classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Mint stroke-width:1px, stroke:#5CA87C, fill:#D0F0DB, color:#2D6B4E classDef Rose stroke-width:1px, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 ``` ### Multiple success criteria Evaluate two or more conditions that must both pass for the sequence to succeed. Add a second comparison path with its own sensor, threshold, and calculation, then connect both comparisons through an OR block. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart LR T["Trigger"]:::Mint CV["Cmd Value"]:::Lavender WC["Write Cmd"]:::Navy subgraph path1["Criteria 1"] S1["Sensor 1"]:::Lavender BT1["Base Threshold 1"]:::Lavender CP1["Calc Param 1"]:::Lavender CL1["Calc Logic"]:::Navy COMP1["Comparison"]:::Rose end subgraph path2["Criteria 2"] S1b["Sensor 1"]:::Lavender BT2["Base Threshold 2"]:::Orange CP2["Calc Param 2"]:::Orange CL2["Calc Logic"]:::Navy COMP2["Comparison"]:::Navy end OR["OR"]:::Mint SO["Sequence
      Output"]:::Mint TC["Time Control"]:::Navy T --> WC CV --> WC S1 --> COMP1 BT1 --> CL1 CP1 --> CL1 CL1 --> COMP1 S1b --> COMP2 BT2 --> CL2 CP2 --> CL2 CL2 --> COMP2 COMP1 --> OR COMP2 --> OR OR --> SO OR -.-> TC linkStyle 0,1,2,3,4,5,6,7,8,9,10,11,12 stroke:#374D7C linkStyle 13 stroke:#374D7C classDef Lavender stroke-width:1px, stroke:#9B8EC4, fill:#E2E0F0, color:#4A3780 classDef Navy stroke-width:1px, stroke:#374D7C, fill:#B8D4E8, color:#374D7C classDef Mint stroke-width:1px, stroke:#5CA87C, fill:#D0F0DB, color:#2D6B4E classDef Rose stroke-width:1px, stroke:#FF5978, fill:#FFDFE5, color:#8E2236 classDef Orange stroke-width:1px, stroke:#E67E22, fill:#FDEBD0, color:#935116 style path1 fill:none, stroke:#9B8EC4, stroke-dasharray:5 style path2 fill:none, stroke:#E67E22, stroke-dasharray:5 ``` **String builder template for multiple success criteria:** 1. This sequence will command the *VAV setpoint* to 2. `Calc Value` 3. The equipment has a maximum of 4. `Max Duration` 5. seconds to achieve the success criteria. 6. *In order to succeed the VAV DAT must be less than* 7. `Calculated Threshold 1` 8. *or less than* 9. `Calculated Threshold 2` 10. . The threshold of 11. `Calculated Threshold 1` 12. *assumes that when heating is stopped the VAV discharge air temp will approach the VAV zone temp with a buffer of* 13. `Calc Param 1` 14. . The threshold of 15. `Calculated Threshold 2` 16. *assumes that when heating is stopped the VAV discharge air temp will approach the AHU discharge air temperature with a buffer of* 17. `Calc Param 2` > [!TIP] > > Start with the standard architecture and expand as needed. The logic for multiple write commands, calculated values, and multiple criteria can be combined within a single sequence. ## Definitions > [accordion] Workflow components > > | Term | Definition | Examples | > | - | - | - | > | **Device type** | The type of equipment the workflow is compatible with | VAV, FCU, AHU | > | **Sensor inputs** | Points that read from a device to indicate operating conditions | Zone Temp, Discharge Air Temp, Discharge Airflow | > | **Required states** | Constant values required to ensure the equipment is in a suitable state | AHU Occupied Mode, Boiler Run Status, VAV Heating Mode | > | **Parameters** | User-adjustable preferences that specify requirements such as thresholds, time limits, and command values | Airflow low limit, Max Duration, Damper Command | > | **Initial condition logic** | Prints the starting state of equipment at test start | Initial zone temperature, airflow, damper position | > | **Pre-condition logic** | Checks initial conditions to ensure the test produces a valid mechanical result | Verify hot water loop run status before testing heating | > | **Sequence logic** | Commands equipment and checks success criteria to produce pass/fail scores | Close Damper sequence commands damper and checks airflow | > | **Release** | Ends the test and releases all overrides | Required in every workflow | > [accordion] Sequence components > > | Term | Definition | Examples | > | - | - | - | > | **Trigger** | Logical input that starts a process | Starts a sequence, writes a command, or outputs a string | > | **Write command** | Issues a command to a device point. Outputs true on success, false on failure. | VAV Damper Command to 0%, Fan Commanded On | > | **Command value** | Fixed value or user input determining the value written via a command | 0%, 100%, ON | > | **Primary sensor input** | Response variable compared directly to the calculated threshold | VAV Discharge Temperature, VAV Airflow | > | **Base threshold** | Key value from which the final requirement is calculated | Max Occ Cooling Flow, AHU DAT | > | **Calculation parameter** | User-adjustable parameter that modifies the difficulty of the test | % of Max Occ Cooling Flow, AHU Temp Differential | > | **Calculation logic** | Operation between the base threshold and calculation parameter | 90% \* Max Occ Cooling Flow, AHU DAT + Temp Differential | > | **Calculated threshold** | Final value the sensor must reach to pass or fail | Airflow Threshold = 90% of Max Occ Cooling Flow | > | **Comparison** | Comparison between the sensor and threshold(s) | Less than or equal, greater than or equal, equals | > [accordion] String builder messages > > | Term | Definition | Example | > | - | - | - | > | **Sequence description** | Describes the command, time limit, success criteria, and threshold calculations | "This sequence will command the discharge damper to 0%. The equipment has a maximum of 300 seconds..." | > | **Command failure** | Informs if the command to equipment succeeded | "Override not Successful." | > | **Minimum duration** | Informs of the minimum wait time before evaluating | "Override Command Successful. Start checking feedback after 30 seconds." | > | **Sensor reading** | Displays measured value and required threshold repeatedly | "Discharge Airflow: 200 Airflow threshold: 100" | > | **Stabilization** | Buffer time period after success/failure before the next sequence | "Operation Successful. Wait for 30 seconds for the system to stabilize" | > | **Sequence success/fail** | Confirms if the sequence succeeded or failed | "Damper successfully opened." | ## Next steps > [card] [Workflow logic blocks](/products/ftt/workflow-logic-blocks) > > Reference guide for all available block types. > [card] [Workflows](/products/ftt/workflows) > > Manage and test workflows in the logic builder. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule testing. > [card] [Deployment guide](/products/ftt/deployment) > > Roll out library workflows before you invest in custom logic. # Workflow logic blocks Source: https://docs.kodelabs.com/products/ftt/workflow-logic-blocks Reference guide for all logic block types available in the FTT workflow builder, including read, write, parameter, arithmetic, conditional, timing, and testing blocks. Logic blocks are the building components of FTT workflows. Each block performs a specific operation. You connect blocks on the canvas to create the testing logic for your equipment. This page is a block-type reference. For how a finished workflow decides pass or fail, see [What is Functional Testing?](/products/ftt/overview). For end-to-end custom authoring, see the [Workflow creator guide](/products/ftt/workflow-creator-guide). Most sites start with the [workflow library](/products/ftt/fcu-workflows) before they edit blocks. ## Write blocks Write blocks issue commands (overrides) to device points. Each write block activates as soon as data flows into its trigger input. The trigger accepts number, boolean, or string data observations. Use write blocks to command equipment during test sequences, such as closing a damper or turning on a fan. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). Every write block has the following fields: **Name** `Field` A familiar name for easy reference and reporting. **Field** `Field` Opens a dialog to select the point you want to write to. The point must meet the block's type requirements. **Input** `Field` The value to write, specified as a parameter or a static value. Each write block produces a single **Output** that returns a true/false value indicating whether the point was written to successfully. ### Write block types > [tab] String Write > > Writes a string value to a point. Specify the value using a parameter or a static string. > > ![String Write logic block showing trigger input, name field, field selector, write value input, and boolean output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-string-write-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=214b594ac8a7344df879164e957e4903) > > String Write block with trigger, name, field, input, and output > [tab] Number Write > > Writes a numeric value to a point. Specify the value using a parameter or a static number. > > ![Number Write logic block showing trigger input, name field, field selector, numeric input, and boolean output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-number-write-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=5bd5ba72d04ca1d77ed092ec4f6b1aed) > > Number Write block with trigger, name, field, input, and output > [tab] Boolean Write > > Writes a true or false value to a point. Specify the value using a parameter or a static "true" or "false". > > ![Boolean Write logic block showing trigger input, name field, field selector, boolean input, and boolean output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-boolean-write-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=67753d136e83da6aa05bc1bce83d2b45) > > Boolean Write block with trigger, name, field, input, and output > [tab] Enum Write > > Writes a list of strings to a point. Specify the value using a parameter or a static list of strings. > > ![Enum Write logic block showing trigger input, name field, field selector, enum list input, and boolean output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-enum-write-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9dac96b6d13448f1967dc1dc2d30323c) > > Enum Write block with trigger, name, field, input, and output ## Read blocks Read blocks bring point data from connected devices into the workflow. Each read block provides two outputs: **Status** (the point's connection status) and **Value** (the current reading from the point). Every read block has the following fields: **Name** `Field` A free-form input for identifying the block. Use a name that matches the point name for easy reference when troubleshooting or reviewing the workflow. **Main / Secondary** `Toggle` Designates whether this block is the main reference point or a supporting point. Every workflow must have one and only one `Main` point. When an event is generated, the main point serves as the reference to other modules within Cloud BMS. All other read blocks are set to `Secondary`. **Field** `Field` Select inside the `Field` input to open a dialog where you can browse and choose the target point. Available points are scoped based on the entities defined in the workflow. If you do not see a point you need, verify that the selected entities contain that field. ### Read block types > [tab] String Point > > Reads the current string value from a point. > > ![String Point logic block showing name field, Main or Secondary toggle, field selector, status output, and string value output](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/ftt/ftt-string-point-block.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=1b1d1eacdcc1e97ae282339bf7e9051c) > > String Point block with name, Main or Secondary toggle, field selector, and status/value outputs > [tab] Number Point > > Reads the current numeric value from a point. > > ![Number Point logic block showing name field, Main or Secondary toggle, field selector, status output, and number value output](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/ftt/ftt-number-point-block.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=9d1d3d96cc86c1ba5f749e8e1fd6a3d1) > > Number Point block with name, Main or Secondary toggle, field selector, and status/value outputs > [tab] Boolean Point > > Reads the current boolean value from a point. > > ![Boolean Point logic block showing name field, Main or Secondary toggle, field selector, status output, and boolean value output](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/ftt/ftt-boolean-point-block.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=db0feef15e7390323bc433251fcdaa45) > > Boolean Point block with name, Main or Secondary toggle, field selector, and status/value outputs > [tab] Enum Point > > Reads the current enum-mapped values from a point. The Field selector derives from device entities and enum mapping. > > ![Enum Point logic block showing name field, Main or Secondary toggle, field selector, status output, and enum value output](https://mintcdn.com/kodelabs/Cw3urP8HmHTik-28/images/kode-os/ftt/ftt-enum-point-block.png?fit=max\&auto=format\&n=Cw3urP8HmHTik-28\&q=85\&s=b66b5ac11264ad9f7281fe2ad3d7c4bd) > > Enum Point block with name, Main or Secondary toggle, field selector, and status/value outputs ### Read arrays Use Read Array blocks when a device has two or more distinct fields with the same name. Within a device, it is possible to have two distinct points that share the same name, appended with an identifying number. The system identifies their array potential and allows you to select that type. For example, if a device has two compressor stages, determining whether a compressor is running requires checking both points. With a Read Array block, you bring in a single block instead of two separate read blocks. This simplifies the workflow and eliminates the need to cover all variations of multi-stage compressors within a single routine. Each Read Array block has the following fields: **Name** `Field` A familiar name for the set of points, used for reference and reporting. **Field** `Field` Select the set of points to read from. Points are derived from device entities and templating multiple points to the same field. Each Read Array block outputs two lists: **Status** (one status per point in the array) and **Value** (one value per point in the array). > [tab] String Array > > Reads a list of string values from multiple points mapped to the same field. > > ![String Array logic block showing name field, field selector, status array output, and string value array output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-string-array-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2204f64d579c636fac212d735fc1b131) > > String Array block with name, field selector, and array outputs for status and string values > [tab] Number Array > > Reads a list of numeric values from multiple points mapped to the same field. > > ![Number Array logic block showing name field, field selector, status array output, and number value array output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-number-array-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=f222d2ebb60e3fbfe3e2a328d3dca0d8) > > Number Array block with name, field selector, and array outputs for status and number values > [tab] Boolean Array > > Reads a list of boolean values from multiple points mapped to the same field. > > ![Boolean Array logic block showing name field, field selector, status array output, and boolean value array output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-boolean-array-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=400efd95c4590059a7e87020932018b3) > > Boolean Array block with name, field selector, and array outputs for status and boolean values > [tab] Enum Array > > Reads a list of enum values from multiple points mapped to the same field. > > ![Enum Array logic block showing name field, field selector, status array output, and enum value array output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-enum-array-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=291ff746ffd7ce4271dcded3ed586c6e) > > Enum Array block with name, field selector, and array outputs for status and enum values ## Parameter blocks Parameter blocks provide a way to customize values for projects that use the workflow, without editing the workflow itself. The values you set in parameter blocks become available when configuring a job that uses the workflow. Users can override defaults during project setup. For on-demand (manual) runs from a device, operators only see and edit these parameters when they have **View FTT Parameters for Manual Test** in Launchpad. That permission does not change how you create parameter blocks here. See [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). Every parameter block has the following fields: **Name** `Field` A human-readable label for the parameter. Use a descriptive name that can be understood by anyone, such as "Pressure Min Threshold" or "Cooling - Delta." Clear naming minimizes confusion when accessed later to troubleshoot or understand the intent. **Hint** `Field` A string input that appears when the information icon is hovered over during parameter configuration. Use as many words as necessary to communicate the intent of the parameter, its expected range, and any constraints. **Value** `Field` The default value for the parameter. When you edit parameters during job setup, you alter this input to the algorithm. Users can override this value when setting up an FTT project. The block outputs the value specified in the `Value` field (or the user's override) for use by downstream blocks. ### Parameter block types > [tab] String > > Outputs a string value. Specify the string to output from this block. Values are available for customization during configuration. > > ![String parameter logic block showing name field, hint field, value field, and output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-string-parameter-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=be0b49006a540dc7d24d05461bd6e03a) > > String parameter block with name, hint, value, and output > [tab] Number > > Outputs a number value. Specify the number to output from this block. Values are available for customization during configuration. > > ![Number parameter logic block showing name field, hint field, numeric value field, and output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-number-parameter-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=5a34752d1ff5516577cdca67607223ae) > > Number parameter block with name, hint, value, and output > [tab] Boolean > > Outputs a boolean value. Specify the boolean to output from this block. Values are available for customization during configuration. > > ![Boolean parameter logic block showing name field, hint field, boolean value field, and output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-boolean-parameter-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=35ac995c6ba5c9a3fd3055e4d392444b) > > Boolean parameter block with name, hint, value, and output ### Hint tooltip The `Hint` text appears as an information bubble next to the value field when a user configures the parameter during project setup. ![Parameter hint tooltip showing descriptive text for Pressure Min Threshold during project configuration](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-parameter-hint-tooltip.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=e7f46b6f517178af08dc6ac75f02e525) Parameter hint displayed as a tooltip during project configuration ## Arithmetical blocks Arithmetical blocks perform mathematical operations on number inputs. Use these blocks to calculate thresholds, derive values, and process sensor data. Multi-input blocks (Difference, Max, Mean, Min) accept two or more inputs. Click the **+** button on the block to add additional input fields. Each input accepts a linked number output from another block or a static value set directly in the field. The block outputs a single **Result** value. Single-input blocks (Absolute) accept one input and output a single **Result** value. > [tab] Difference > > Calculates the difference between input values. Outputs the post-calculated value. Use the **+** button to add more operands. > > ![Difference arithmetic block showing two numeric inputs, add operands button, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-difference-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=4d3f734782499dab60869e422457acea) > > Difference block with multiple inputs, add operands button, and result output > [tab] Max > > Returns the largest value from all inputs. Use the **+** button to add more inputs. > > ![Max arithmetic block showing two numeric inputs, add inputs button, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-max-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b11f5d049bb65da1280139b5f8983320) > > Max block with multiple inputs, add inputs button, and result output > [tab] Mean > > Returns the average of all input values. Use the **+** button to add more inputs. > > ![Mean arithmetic block showing two numeric inputs, add inputs button, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-mean-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b93fe94e789e8ec821aca953d4dadb77) > > Mean block with multiple inputs, add inputs button, and result output > [tab] Min > > Returns the smallest value from all inputs. Use the **+** button to add more inputs. > > ![Min arithmetic block showing two numeric inputs, add inputs button, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-min-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=cc8b7e720f2fcd6cb80ae5b0cb349848) > > Min block with multiple inputs, add inputs button, and result output > [tab] Absolute > > Returns the non-negative value of the input. Accepts a single number input or a static value. > > ![Absolute arithmetic block showing single numeric input and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-absolute-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=6d04f622ef73c835ae6778ebe6937468) > > Absolute block with single input and result output > [tab] Sum > > Adds all input values together. Use the **+** button to add more operands. > > ![Sum arithmetic block showing two numeric inputs, add operands button, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-sum-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=b51ffc140f4612e962afd7ca617acaa3) > > Sum block with multiple inputs, add operands button, and result output > [tab] Product > > Multiplies all input values together. Use the **+** button to add more operands. > > ![Product arithmetic block showing two numeric inputs, add operands button, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-product-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=1590614df9554512c6fa010aa7273087) > > Product block with multiple inputs, add operands button, and result output > [tab] Quotient > > Divides the first input by the second. Use the **+** button to add more operands for chained division. > > ![Quotient arithmetic block showing two numeric inputs, add operands button, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-quotient-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6ed3dd86a6241865fdf78bbea132392d) > > Quotient block with multiple inputs, add operands button, and result output > [tab] Modulo > > Returns the remainder from dividing the first input by the second. > > ![Modulo arithmetic block showing two numeric inputs and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-modulo-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d9ff26452a329d09561e49ded230bb72) > > Modulo block with two inputs and result output ## Array operation blocks Array operation blocks process a list of values collected from Read Array blocks or Buffer blocks. Each block accepts a list input and outputs a single result value. Use these blocks to analyze trends and compute statistics. > [tab] Delta > > Returns the difference between the minimum and maximum values in the list. > > ![Delta array operation block showing list input and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-delta-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=f7124df01d2e85578812afb5908eb318) > > Delta block with list input and result output > [tab] Max Array > > Returns the largest number in the list. > > ![Max Array operation block showing list input and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-max-array-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=62f97a3bd19fb847da641b2fe872c1d5) > > Max Array block with list input and result output > [tab] Length > > Returns the count of items in the provided list. Accepts lists of numbers, booleans, or strings. > > ![Length array operation block showing list input and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-length-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=a2d2cc7d43074a15fad556e04d603565) > > Length block with list input and result output > [tab] Mean Array > > Returns the mean of the numbers in the list. Choose between a weighted mean or a simple average. > > ![Mean Array operation block showing weighted toggle, list input, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-mean-array-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=573a65871ae917a0058bd06aa6452579) > > Mean Array block with weighted/simple toggle, list input, and result output > [tab] Min Array > > Returns the smallest number in the list. > > ![Min Array operation block showing list input and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-min-array-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=c2ea7d52ace99afab9940a981945815c) > > Min Array block with list input and result output > [tab] Sort Array > > Returns the input list sorted in ascending or descending order. > > ![Sort Array operation block showing sort order toggle, list input, and sorted list output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-sort-array-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=d3cfcbad678249bf23f76086e1284781) > > Sort Array block with ascending/descending toggle, list input, and sorted list output > [tab] Std Deviation > > Returns the standard deviation of the numbers in the list. Choose between a weighted or simple standard deviation. > > ![Std Deviation operation block showing weighted toggle, list input, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-std-deviation-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=83d198074683c633f1f63bd550372ed3) > > Std Deviation block with weighted/simple toggle, list input, and result output > [tab] Sum Array > > Returns the sum of all numbers in the list. > > ![Sum Array operation block showing list input and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-sum-array-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=d889c5350f1dc8bc6d87c68d60a9c3d3) > > Sum Array block with list input and result output > [tab] Variance > > Returns the variance of the numbers in the list. Choose between a weighted or simple variance. > > ![Variance operation block showing weighted toggle, list input, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-variance-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=1e5a94cff507cbe203ebae416afd711e) > > Variance block with weighted/simple toggle, list input, and result output ### Example workflows **Difference between highest and lowest values over five minutes:** Read Number > Buffer Time (5 min) > Array Sort (Ascending) > Array Delta **15-minute rolling average:** Read Number > Buffer Time (15 min) > Array Mean ## Conditional and switch blocks Conditional and switch blocks direct the workflow's execution path based on input data. ### If block The If block evaluates a true or false condition and routes data to one of two outputs. Link a block that outputs a boolean to the input. The block routes to `Do` when the condition evaluates to true and to `Else` when it evaluates to false. ![If conditional block showing boolean input, Do output for true condition, and Else output for false condition](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-if-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d53538315f09bcd8950ec1f5d56d22b4) If block with boolean input and Do/Else outputs ### Switch blocks Switch blocks evaluate a boolean conditional input and return a value based on the result. The top return value outputs when the condition is true, and the bottom return value outputs when the condition is false. You can use block inputs or static values. > [tab] String Switch > > Outputs the corresponding string associated to the evaluated true or false condition. > > ![String Switch block showing conditional boolean input, two string return values, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-string-switch-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6493116ca2f6a7d67654e78a23f2170e) > > String Switch block with conditional input, two return values, and string result output > [tab] Numeric Switch > > Outputs the corresponding number associated to the evaluated true or false condition. > > ![Numeric Switch block showing conditional boolean input, two number return values, and result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-numeric-switch-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=c2c41e729102667fc1f0da65e8d75f93) > > Numeric Switch block with conditional input, two return values, and number result output > [tab] Boolean Switch > > Outputs the boolean associated to the evaluated true or false condition. > > ![Boolean Switch block showing conditional boolean input, two boolean return values, and result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-boolean-switch-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=0a45d13c8cfddce18aea8b69f0e34d55) > > Boolean Switch block with conditional input, two return values, and boolean result output ### Gate blocks Gate blocks control the flow of data through the workflow by acting as barriers that open or close based on a trigger. > [tab] Skip Until > > Prevents data from passing through until a data observation arrives at the trigger. The trigger accepts number, boolean, or string data. When an input is linked, an output of the same data type appears on the right. > > ![Skip Until gate block showing trigger input and data input with matching output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-skip-until-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=bd58da22cc5ebd82e1d58d6d0cf52fb1) > > Skip Until block with trigger and input/output > [tab] Take Until > > Passes data through until a data observation arrives via the trigger, then stops. The trigger accepts number, boolean, or string data. When an input is linked, an output of the same data type appears on the right. > > ![Take Until gate block showing trigger input and data input with matching output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-take-until-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=1914c7a2a9e1051c69b57d293e930f79) > > Take Until block with trigger and input/output ## Logical and comparison blocks ### Logical blocks Logical blocks evaluate boolean inputs and produce a boolean result. Use the **+** button to add more operands. > [tab] And > > Returns true only when all input values are true. > > ![And logical block showing two boolean inputs, add operands button, and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-and-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=54644b2fada281d1c3e7933015d86694) > > And block with multiple boolean inputs, add operands button, and result output > [tab] Or > > Returns true if any input value is true. > > ![Or logical block showing two boolean inputs, add operands button, and boolean result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-or-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=763ee7fb9c3b333b998577b6ad5c7362) > > Or block with multiple boolean inputs, add operands button, and result output ### Not block The Not block inverts a single boolean input value. True becomes false, and false becomes true. ![Not logical block showing single boolean input and inverted boolean result output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-not-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=453e9e1ac6baef678372c0a43f8a86ec) Not block with single boolean input and inverted result output ### Merge block The Merge block combines multiple inputs of the same data type (number, boolean, or string) into a single output. As a data observation is received from any of the inputs, it is sent to the output regardless of order. Use the **+** button to add more inputs. ![Merge block showing two inputs of the same type, add inputs button, and single output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-merge-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=427fecc43ec73de860fa3d2a796b718e) Merge block with multiple inputs and single output of matching type ### Comparison blocks Comparison blocks evaluate two values and output a boolean result. You can use linked inputs or static values. > [tab] Equals > > Outputs true if both inputs are evaluated as equal. Accepts number, boolean, or string operands (both must be the same type). > > ![Equals comparison block showing left operand, right operand, and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-equals-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=69715230c0f7a9eae8373ce62d054fa5) > > Equals block with left and right operands and boolean result output > [tab] Greater Than > > Outputs true if the left operand is greater than the right operand. > > ![Greater Than comparison block showing two number inputs and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-greater-than-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=7d124031a48601a16acaae52a60f1005) > > Greater Than block with two number inputs and boolean result output > [tab] Less Than > > Outputs true if the left operand is less than the right operand. > > ![Less Than comparison block showing two number inputs and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-less-than-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=d200d587b68c694f76a207489933d6dd) > > Less Than block with two number inputs and boolean result output > [tab] All > > Outputs true if all items in the input list match the specified value. Link a list containing items of the same type as the value. > > ![All comparison block showing list input, value input, and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-all-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=5457c133324a0f3d5e4accd4ac718c9c) > > All block with list input, value input, and boolean result output > [tab] In > > Outputs true if the data observation received by the value input is found as an item in the input list. > > ![In comparison block showing list input, value input, and boolean result output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-in-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=1d2723565edc2259a7b344f1f971a597) > > In block with list input, value input, and boolean result output ## Timing and buffering blocks ### Timing blocks * **Delay On**: requires a condition to remain true for a specified duration before passing it forward * **Delay Off**: requires a condition to remain false for a specified duration before closing * **Timer**: measures how long a condition has been in a specific state ### Audit and Debounce blocks > [tab] Audit > > Waits for a specified amount of time and outputs the last value received from the input. Configure the wait time unit (seconds, minutes, or hours) and the count of time units to wait. > > ![Audit timing block showing wait time dropdown, static number value, data input, and matching type output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-audit-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=899acd5d33ab62725827b4bc80d2cab0) > > Audit block with wait time configuration, count input, data input, and output > [tab] Debounce > > Waits for a specified amount of time and outputs a value only if that value has been unchanged during that period. Configure the wait time unit (seconds, minutes, or hours) and the count of time units to wait. > > ![Debounce timing block showing wait time dropdown, static number value, data input, and matching type output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-debounce-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9ebcfaecaf74b28e16b3b6ec79ddb739) > > Debounce block with wait time configuration, count input, data input, and output ### Buffer blocks Buffer blocks collect values from an input into a list. The list is returned when the configured condition (time or count) is met. > [tab] Buffer Time > > Collects values from the input into a list that is returned after the specified amount of time. Configure the time unit (seconds, minutes, or hours) and the duration. > > ![Buffer Time block showing time unit dropdown, static number value, data input, and list output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-buffer-time-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=96646a524e3393c45cdbe7bd1027a5d0) > > Buffer Time block with time settings, count input, data input, and list output > [tab] Buffer Count > > Collects values from the input into a list that is returned when the count is satisfied. Specify the number of values to collect. > > ![Buffer Count block showing count setting, data input, and list output](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-buffer-count-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b053b5e00a5cde6567bae2112f9a4a0f) > > Buffer Count block with count setting, data input, and list output ## Testing blocks (FTT) FTT-specific blocks manage the testing sequence lifecycle. These blocks handle sequence scoring, pass/fail evaluation, stabilization periods, and the release of equipment overrides at test completion. > [tab] Sequence > > Activates as soon as a data observation goes into its trigger. Outputs a true/false value indicating whether the sequence was successful. Configure the sequence name and count. > > ![Sequence testing block showing trigger, name field, sequence count, boolean input, and success output](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-sequence-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=e2ea2e34c0c6219d2bf81fee9c2f364e) > > Sequence block with trigger, name, sequence count, input, and pass/fail output > [tab] Logger > > Sends a string value to the workflow logger for debugging and reporting. Link a string output or enter a static string value. > > ![Logger testing block showing string input and static value option](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-logger-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=33ce18aff9ae1a080ad34005cc68ac8d) > > Logger block with string input > [tab] Archive > > Initiates when a data observation goes into its trigger. The trigger accepts number, boolean, or string data. Use this block to archive data at specific points in the test sequence. > > ![Archive testing block showing trigger input accepting number, boolean, or string data](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-archive-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=b80ec17797dab8dad176e0682b564957) > > Archive block with trigger input > [tab] Interrupt > > Initiates when a data observation goes into its trigger. The trigger accepts number, boolean, or string data. Use this block to interrupt the test sequence. > > ![Interrupt testing block showing trigger input accepting number, boolean, or string data](https://mintcdn.com/kodelabs/i9tCc_I6OZNqDXAw/images/kode-os/ftt/ftt-interrupt-block.png?fit=max\&auto=format\&n=i9tCc_I6OZNqDXAw\&q=85\&s=9a4a9f77e2ae451fe57ee4ff9c7bb6f7) > > Interrupt block with trigger input > [tab] Release > > Initiates when a data observation goes into its trigger. The trigger accepts number, boolean, or string data. When the Release block executes, the test ends and all commands issued to the equipment during the test are released. > > ![Release testing block showing trigger input accepting number, boolean, or string data](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-release-block.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=86775c0112d3d701351d3161f67d2185) > > Release block with trigger input > [!WARNING] > > Every FTT workflow must end with a Release block. When the Release block executes, the test ends and all commands issued to the equipment during the test are released. ## Time control parameters Most workflows use three standard time control parameters applied to each sequence: | Parameter | Description | Units | | - | - | - | | `Min Sequence Duration` | Minimum time the equipment has to respond to a command before evaluation begins | Seconds | | `Max Sequence Duration` | Maximum time allowed for the equipment to meet success criteria before the sequence fails | Seconds | | `Stabilization Time` | Buffer time between sequences to allow the equipment to return to a neutral state | Seconds | ## Next steps > [card] [Workflows](/products/ftt/workflows) > > Create, test, and manage workflows using the logic builder and debugger. > [card] [Workflow creator guide](/products/ftt/workflow-creator-guide) > > Follow the end-to-end process for designing and building custom workflows. > [card] [What is Functional Testing?](/products/ftt/overview) > > Review how library workflows decide pass or fail before you edit blocks. # Workflows Source: https://docs.kodelabs.com/products/ftt/workflows View, create, and manage FTT testing workflows using the logic builder and debugger in Cloud BMS. FTT workflows define the testing logic for your building equipment. Each workflow specifies the sequences of commands, sensor readings, success criteria, and report output for a specific test type. Cloud BMS provides a pre-configured library of workflows and a logic builder for creating custom tests. > [!NOTE] > > Navigate to `FTT` from the left sidebar, select the three-dot menu at the top right, and choose `Workflows`. Most sites start with the library. Run a library workflow on one device before you edit logic. See [How FTT decides if a heater works](/products/ftt/overview#example-how-ftt-decides-if-a-heater-works) for scoring, and [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device) for an on-demand run. Operators who run on-demand tests may or may not see workflow parameters, depending on the **View FTT Parameters for Manual Test** permission in Launchpad. Creators still define parameter blocks and defaults in the workflow. See [Test results](/products/ftt/test-results#run-a-test-on-a-single-device) and the [permissions reference](/products/launchpad/client-organizations/apps/permissions-reference). Custom authoring is covered in the [Workflow creator guide](/products/ftt/workflow-creator-guide). ## Workflows list The workflows list displays all available workflows with key details. Use the search bar and `Canonical Type` filter to find specific workflows. ![FTT workflows list showing search results for FCU heating workflows with name and description columns](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflows-list.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=e15e2a5d71203dd3b9f643af2f5a1527) The workflows list with search and canonical type filtering | Column | Description | | - | - | | `Name` | Workflow name | | `Description` | Summary of what the workflow tests | | `Device Types` | Equipment types compatible with the workflow | | `Device References` | Reference devices required by the workflow (such as a parent AHU) | ### Row actions Select the three-dot menu on any workflow row to access available actions: ![Workflow row three-dot menu showing Edit Workflow, Export Workflow, Duplicate Workflow, and Delete Workflow options](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-row-actions.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=1615c11ee299a9b79ac7d9c5b6227f86) Row actions available from the three-dot menu on a workflow * **Edit Workflow**: open the workflow in the logic builder * **Export Workflow**: export the selected workflow as a JSON file * **Duplicate Workflow**: create a copy of the workflow * **Delete Workflow**: permanently remove the workflow ## Export workflows Export workflows to share them across sites or create backups. 1. Select `Export` from the top toolbar. 2. Select the checkboxes next to the workflows you want to export. 3. Select `Export`. The workflows download as an `FTT Export.json` file. ![Export workflows screen showing a list of FCU workflows with checkboxes for selection and an Export button](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-export-select.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=4708d67cd422e53808536d0b086b6360) Select workflows to export with checkboxes, then select Export > [!TIP] > > You can also export a single workflow directly from the row actions three-dot menu by selecting `Export Workflow`. ## Import workflows Import workflows from a previously exported JSON file. 1. Select `Import` from the top toolbar. 2. Choose a file or drag and drop the JSON export file into the upload area. ![Import Workflows dialog with a dashed border upload area showing Choose a file or drop it here](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-import-upload.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=d0281c549c48afcd897c7d2b5f1326b3) The Import Workflows upload dialog 3. Review the imported workflows. Use the search bar and `Canonical Type` filter to find specific workflows. 4. Select the workflows you want to import. For each workflow, choose whether to **Replace** an existing workflow or create a new one. 5. Select `Import` to complete the process, or `Discard` to cancel. ![Import Workflows review screen showing two FCU workflows with name, description, device type columns and Replace dropdown for each row](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-import-review.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=3101623ab07ef97dffd2dd1e5bf4636d) Review imported workflows and choose Replace or create new for each ## Create a workflow **1. Set workflow details** Select `+ Create Workflow`. Complete the required fields on the `Workflow Details` tab: ![Workflow Details tab showing V3 FCU Cooling workflow with name, description, max duration in minutes, and FCU and Loop device entities](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-details.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=889d4e28a718798676877170beeb15f8) The Workflow Details tab with name, description, max duration, and device configuration | Field | Description | | - | - | | `Name` | A descriptive name for the test, such as "V3 - FCU Cooling" | | `Description` | Explanation of what the workflow tests | | `Max Duration in Minutes` | Maximum time the workflow is allowed to run | Select `+ Add Devices` to configure the base and reference devices for the workflow. Set the device name, select canonical types, and choose the required entities. ![Add Devices dialog showing FCU device with fcu, ahu, vav canonical types selected and entity list including CHWVPRC, DFPRC, DTS, and OM](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-add-devices.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=fd23040217197359494fdc5d23dc5652) The Add Devices dialog for configuring canonical types and entities | Field | Description | | - | - | | `Name As` | Device reference name used in the workflow logic | | `Canonicals` | Equipment canonical types for the device | | `Entities` | Entity definitions required by the workflow | **2. Build the logic** Open the `Logic` tab. Drag and drop logic blocks from the left panel onto the canvas to build the testing sequence. ![Logic tab showing V3 FCU Cooling workflow canvas with Initial Conditions, Loop, FCU, Required States, Parameters blocks connected to Pre-Conditions Check and if blocks](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-logic-builder.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=b056b1ccf73eeb40a6cfee44902b4e12) The Logic tab showing the visual workflow builder with connected blocks A standard workflow follows this structure: 1. **Initial conditions**: print the starting state of the equipment 2. **Pre-condition checks**: verify the equipment is ready for testing 3. **Control sequences**: command the equipment and evaluate responses 4. **Release**: end the test and release all overrides > [!NOTE] > > See [Workflow logic blocks](/products/ftt/workflow-logic-blocks) for a complete reference of available block types. **3. Test with the debugger** Open the `Debugger` tab. The left sidebar displays parameters and inputs. The main screen shows the simulator output. ![Debugger tab showing PARAMS panel with FCU Fan Cmd percent Low Limit, Loop Differential Pressure Low Limit, Max Sequence Duration, Min Sequence Duration, Stabilization Time, Chilled Water Valve Close Cmd, and Stop Cooling DAT Threshold parameters](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-debugger-params.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=a0cc19e40522d6c9e252e1c1095cec95) The Debugger tab with PARAMS panel and Start Simulation button 1. Review the `PARAMS` section and adjust parameter values for testing. 2. Select `Start Simulation` to begin. ![Debugger simulator running V3 FCU Cooling showing Starting phase with workflow description and initial conditions log entries at 1:34 PM](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-debugger-running.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=feb5d08c95778428ef5664dd834146b7) The simulator running a workflow showing the starting phase and initial conditions 3. Update `INPUT` values to simulate different equipment conditions, then select `Send`. ![Debugger showing INPUTS panel with Differential Pressure, Occ Mode, Fan percent Cmd, Chilled Water Valve Cmd, and DAT fields with status dropdowns set to ok, while the simulator shows Pre-Condition Check sequence initialized](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/ftt/ftt-workflow-debugger-inputs.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=4858378c5694962a43dfcee9c06bd345) The INPUTS panel with sensor values and status dropdowns during a Pre-Condition Check 4. Verify the workflow produces the expected response for each scenario. > [!TIP] > > Delay times run in real time during simulation. Temporarily change time units to seconds on timer blocks to speed up testing. Return to the correct units before deploying. > [!TIP] > > Test boundary values thoroughly. Verify conditions that should pass and conditions that should fail. This catches threshold errors before deployment. **4. Save the workflow** Select `Save`. The workflow appears in the workflows list and becomes available for use in FTT projects. ## Next steps > [card] [FCU workflows](/products/ftt/fcu-workflows) > > Review heating and cooling library workflows and parameters. > [card] [Workflow logic blocks](/products/ftt/workflow-logic-blocks) > > Explore the available block types for building workflow logic. > [card] [Workflow creator guide](/products/ftt/workflow-creator-guide) > > Design and build custom workflows after you know the library. > [card] [FTT projects](/products/ftt/projects) > > Assign workflows to devices and schedule automated testing. # Avigilon ACM (Access Control Manager) Source: https://docs.kodelabs.com/products/integrations/access-control/avigilonACM Connect Avigilon ACM (Access Control Manager) to KODE OS for access control data > Connect Avigilon ACM (Access Control Manager) to KODE OS for access control data integration ## Overview Use this integration to connect your Avigilon Access Control Manager (ACM) system to KODE OS. You can discover devices and data points, then collect door- and access-related sensor and non-sensor data through pull-based REST collection from ACC Admin Tool or Avigilon Cloud Services. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Avigilon ACM (Access Control Manager)](https://kodelabs.com/integration/avigilon-acm/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites To integrate with the Avigilon Control Center, ensure you have the following details: * An active account to the ACC Admin Tool (on‑prem) or Avigilon Cloud Services portal with admin permissions. * Valid username and password credentials for the ACC Admin Tool or Avigilon Cloud Services. Password Client Name\* See Step 1 User Key\* URL\* See Step 2 Fields marked with an asterisk \* are mandatory for completing the integration. ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Avigilon Web Endpoint API docs](https://docs.avigilon.com/bundle/web-endpoint-api/page/introduction.htm) ## Generate API Credentials 1. **Step 2: Obtain Base URL 3** * Log in to the ACC Admin Tool as an administrator. * Navigate to Site Setup → Security → Application Clients. * Create a new REST client: * Click Add Client. * Enter Client Name (e.g., KODE\_OS\_Integration). * Click Generate Key, then copy the User Key immediately. * Store both values securely (the UI hides the key after you leave): * Client Name * User Key * Create an API service user: * Go to Site Setup → Security → Users * Click Add User, enter Username (e.g., kode\_api\_user) and Password * Assign a role with Site Administrator or custom API‑only permissions. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Avigilon ACM (Access Control Manager)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Avigilon ACM (Access Control Manager) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Avigilon ACM (Access Control Manager), KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `door_position` | Current physical position of the door | -- | No | Polling | | 2 | `normal` | Normal operating state indicator | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including door\_position, normal, collected at regular intervals from connected devices ### ACM Events Access control management events from Avigilon ACM including door access and credential events ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) * **AvigilonACMEvents** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Avigilon ACM (Access Control Manager) system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Avigilon ACM (Access Control Manager) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Avigilon ACM (Access Control Manager) API. # ICT Protege Source: https://docs.kodelabs.com/products/integrations/access-control/ictProtege Connect ICT Protege to KODE OS for access control data > Connect ICT Protege to KODE OS for access control data integration ## Overview Use this integration to connect your ICT Protege access control system to KODE OS. You can discover controllers and doors, then monitor lock status, door position, and related card-usage signals from a centralized view. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [ICT Protege](https://kodelabs.com/integration/ictprotege/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with ICT Protege and access to their API or developer portal * Username and password credentials for the ICT Protege system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **ICT Protege** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | Yes | password | The site identifier in the external system | | **Controller ID** | Yes | password | Configuration field for Controller ID | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the ICT Protege system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from ICT Protege, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `DoorLockStatus` | Current state of the door (open/closed) | -- | No | `lock_status` | Polling | | 2 | `DoorPositionStatus` | Current state of the door (open/closed) | -- | No | `door_status` | Polling | ## What Data You Get ### Point History Time-series readings including DoorLockStatus, DoorPositionStatus, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the ICT Protege system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the ICT Protege system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the ICT Protege API. # Infinias Source: https://docs.kodelabs.com/products/integrations/access-control/infinias Connect Infinias to KODE OS for access control data > Connect Infinias to KODE OS for access control data integration ## Overview Use this integration to connect your Infinias access control system to KODE OS. You can discover controllers and points, monitor lock, door, and controller status, and collect audit logs and incremental events from one place. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Infinias](https://kodelabs.com/integration/infinias/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Infinias and access to their API or developer portal * Username and password credentials for the Infinias system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Infinias** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Last Event ID** | Yes | text | The last processed event ID for incremental collection | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Infinias system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Infinias, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `lockStatus` | **Locked** -- access point is secured / **Unlocked** -- access point is open / **Normal** -- default operating state | -- | No | `lock_status` | Polling | | 2 | `controllerStatus` | Current operating status of the controller | -- | No | `controller_status` | Polling | | 3 | `doorStatus` | Current state of the door (open/closed) | -- | No | `door_status` | Polling | | 4 | `batteryStatus` | Device battery level (%) | % | No | `battery_percentage_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including lockStatus, controllerStatus, doorStatus, batteryStatus, collected at regular intervals from connected devices ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) * **Audit Log** -- Default polling: 10 minutes (min: 10 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Infinias system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Infinias system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Infinias API. # Integriti Source: https://docs.kodelabs.com/products/integrations/access-control/integriti Connect Integriti to KODE OS for access control data > Connect Integriti to KODE OS for access control data integration ## Overview Use this integration to connect your Integriti access control system to KODE OS. You can discover devices and points, collect security and access data, and manage schedules when your deployment supports schedule discovery and updates. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Schedules** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Discover Schedules * Update Schedules ## Prerequisites * An active account with Integriti and access to their API or developer portal * API key or token from the Integriti platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Integriti platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Integriti** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client Version** | Yes | dropdown | The version of the vendor's API client | | **API Key** | Conditional | text | The API key for authenticating with the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Access/Security Events Filter ID** | No | text | The filter ID for access and security events | | **Access Control Rules Filter ID** | No | text | The filter ID for access control rules | | **Input Filter IDs** | No | text | Comma-separated filter IDs for input events | | **Auxiliary Filter IDs** | No | text | Comma-separated filter IDs for auxiliary events | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Integriti system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Integriti, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `state` | Current operating state | -- | No | -- | Polling | | 2 | `status` | Current operating status | -- | No | -- | Polling | | 3 | `holdUp` | **True** -- holdUp is active / **False** -- holdUp is not active | -- | No | -- | Polling | | 4 | `entryState` | **True** -- entryState is active / **False** -- entryState is not active | -- | No | -- | Polling | | 5 | `exitState` | Cumulative count of people exiting | -- | No | -- | Polling | | 6 | `siren` | **True** -- siren is active / **False** -- siren is not active | -- | No | -- | Polling | | 7 | `pulse` | **True** -- pulse is active / **False** -- pulse is not active | -- | No | -- | Polling | | 8 | `defer` | **True** -- defer is active / **False** -- defer is not active | -- | No | -- | Polling | | 9 | `warn` | **True** -- warn is active / **False** -- warn is not active | -- | No | -- | Polling | | 10 | `sirenHoldOff` | **True** -- sirenHoldOff is active / **False** -- sirenHoldOff is not active | -- | No | -- | Polling | | 11 | `userCount` | Number of unique users | count | No | -- | Polling | | 12 | `summary` | Alarm/event summary text | -- | No | -- | Polling | | 13 | `is_on` | **True** -- is\_on is active / **False** -- is\_on is not active | -- | No | -- | Polling | | 14 | `is_open` | **True** -- door is open / **False** -- door is closed | -- | No | `door_status` | Polling | | 15 | `is_forced` | **True** -- medium-priority alarm is active / **False** -- no alarm | -- | No | `medium_priority_alarm` | Polling | | 16 | `open_too_long` | **True** -- medium-priority alarm is active / **False** -- no alarm | -- | No | `medium_priority_alarm` | Polling | ## What Data You Get ### Point History Time-series readings including state, status, holdUp, entryState, exitState, siren, pulse, defer, and 8 more, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Integriti data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | `id` | -- | | **name** | `type` | -- | | **description** | `text` | -- | | **deviceId** | `controller_id` | -- | | **deviceName** | `controllerName` | -- | | **createdAt** | `utcTimeGenerated` | transformed | | **customFields** | `(custom fields)` | custom fields object | ### Access Control Access control records including card reader events, credential verification, and zone access KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **EventLog** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) * **AccessControl** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Integriti system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Integriti platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Integriti system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Integriti API. # Kastle Source: https://docs.kodelabs.com/products/integrations/access-control/kastle Connect Kastle Event Connect to KODE OS for access events and security alarms > Connect Kastle Event Connect to KODE OS for access control and security alarm data ## Overview Use this integration to collect card access events and security alarms from Kastle Event Connect REST API v3. KODE OS stores these records as access logs and alarms for monitoring, investigation, and reporting. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported capabilities * Collect access logs * Collect alarms * Collect historical data ## Prerequisites * A Kastle Event Connect account with REST API v3 access * A Kastle client ID and client secret * The Kastle API base URL for your environment * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Kastle API`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | Kastle Event Connect API base URL | | **Client ID** | Yes | text | Client identifier issued by Kastle | | **Client Secret** | Yes | password | Client secret issued by Kastle | | **Notes** | No | text | Additional connection details | KODE OS exchanges the client credentials for a Bearer token before requesting event data. ## What data you get Kastle provides non-sensor records. This connector does not discover devices or sensor points. ### Access logs Access records include the result, credential, person, location, and event time. | KODE field | Kastle field | | - | - | | `id` | `eventId` | | `result` | `eventStatus` | | `access_time` | `eventTimeUtc` | | `access_time_local` | `eventTimeLocal` | | `credential_id` | `credential.CredentialId` | | `person_id` | `credentialHolder.credentialHolderId` | | `person_name` | `credentialHolder.name` | | `location` | `location.name` and `location.floor` | KODE OS stores additional credential-holder and location attributes in `custom_fields`. Access Log collection has `redactPiiData` on by default. KODE OS then replaces each character of the credential holder name, email, and phone with `*`. Blank values stay blank and are omitted. Alarm collection is not redacted. ### Alarms Alarm records include the alarm name, state, location, source, type, and timestamps. | KODE field | Kastle field | | - | - | | `id` | `eventId` | | `category` | `Access Control` | | `name` | `event.designator` | | `status` | `event.state` | | `started_at` | `eventTimeUtc` | | `created_at` | `eventTimeUtc` | | `location` | `location.name` and `location.floor` | KODE OS stores the location identifiers, `stimId`, source, and event type in `custom_fields`. ## Historical collection Each Kastle request can cover up to 30 days. You can collect up to 90 days of previous events. The connector follows Kastle pagination using `limit` and `offset`. The default page size is 500 records, and the maximum is 2,000. ### Polling schedule * **Access logs and alarms** — Poll approximately every 15 minutes, subject to vendor data latency For more details, see the [Data collection guide](/products/integrations/capabilities/data-collection). ## Use cases Once connected, you can: * Review allowed and denied access events in KODE OS * Investigate alarms with credential-holder and location context * Build access and security audit reports without manual exports ## Troubleshooting > [accordion] Authentication or connection error > > Verify the API URL, client ID, and client secret. Confirm the Kastle application can access Event Connect REST API v3. > [accordion] Historical records are missing > > Keep each requested window within 30 days and the complete lookback within 90 days. Account for vendor processing latency when reviewing the newest events. > [accordion] Collection stops before all events load > > Review the connector logs for pagination errors. Confirm the connection can continue through each `offset` until Kastle returns the complete result set. # OnGuard Source: https://docs.kodelabs.com/products/integrations/access-control/lenel Connect Lenel OnGuard to KODE OS for access control, alarm, and credential data > Connect Lenel OnGuard to KODE OS for access control data integration ## Overview Use this integration to connect your Lenel OnGuard (8.3+) system to KODE OS. You receive real-time access, credential, and alarm activity over SignalR (WebSocket) while REST covers historical polling and inventory-style data such as badges and alarm definitions. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST + SignalR (WebSocket) | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Collect Non-Sensor Data (Access Events, Alarms, Credentials) * Receive Real-Time Events via SignalR (WebSocket) * Collect Historical Data via REST ## Prerequisites * OnGuard 8.3 system with OpenAccess API enabled * Valid username and password credentials for the OnGuard system * A `LENEL_API_KEY` (Application ID) configured as an environment variable in the KODE OS API Integration Service -- this key is shared across all Lenel datasources * Network connectivity from KODE OS to the OnGuard server (both REST and WebSocket endpoints) * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **OnGuard** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Connector Name** | Yes | text | Display name for this connector | | **URL** | Yes | text | Base URL of the OnGuard OpenAccess API server | | **Username** | Yes | text | OnGuard login username | | **Password** | Yes | password | OnGuard login password (encrypted) | ## How Authentication Works OnGuard uses a session-based authentication flow: 1. KODE OS sends credentials to `POST /api/access/onguard/openaccess/authentication` with the `Application-Id` header 2. OnGuard returns a `session_token` and API `version` 3. All subsequent requests include `Session-Token` and `Application-Id` headers > [!NOTE] > > If authentication fails due to invalid credentials, expired password, or invalid application ID, the connector automatically deactivates to prevent account lockout. Check the connector status page if data stops flowing. ## Data Collection Methods OnGuard data is collected through two channels: | Data Type | KODE Entity | Protocol | Frequency | | - | - | - | - | | Hardware Events (door access) | Access Log | SignalR (real-time push) | Instant | | Software Events (credential changes) | Access Log | SignalR (real-time push) | Instant | | Alarm Acknowledgments | Event Log | SignalR (real-time push) | Instant | | Badge/Credential Inventory | Access Card | REST (poll) | Daily backup | | Alarm Definitions | Alarm | REST (poll) | Every hour | ## What Data You Get ### Access Logs Real-time access events from card readers, doors, and entry points, delivered via SignalR WebSocket. | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | `serial_number` | `id` | Unique event identifier | | 2 | `cardholder_key` | `person_id` | Cardholder reference | | 3 | `event_type` | `type` | 0 = Access Granted, 1 = Access Denied | | 4 | `alarm_name` | `description` | Event description text | | 5 | `timestamp` | `created_at` | Local timezone (building TZ per OnGuard cert) | | 6 | `badge_id_str` | `credential_id` | Badge/card identifier | | 7 | `device_id` | `point_id` | Reader/device reference | | 8 | `cardholder_first_name` | `person_name` | Cardholder name | | 9 | `event_subtype` | custom field | Retrieved from `Lnl_EventSubtype` lookup | | 10 | `event_source_name` | custom field | Source reader/panel name | | 11 | `controller_id` | custom field | Controller panel ID | | 12 | `controller_name` | custom field | Controller panel name | | 13 | `segment_id` | custom field | Segment identifier | ### Alarms Alarm definitions collected via REST polling, providing the alarm inventory for the site. | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | `ID` | `id` | Alarm definition ID | | 2 | `Priority` | `priority` | Numeric priority level | | 3 | `Description` | `description` | Alarm description | | 4 | `TextInstructionName` | `name` | Instruction name | | 5 | `TextInstructionData` | `alarm_cause` | Root cause instruction text | | 6 | `Active` | `status` | true = "Active", false = "Inactive" | ### Access Cards Badge and credential inventory collected daily via REST as a backup to real-time SignalR software events. | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | `BADGEKEY` | `id` | Unique badge key | | 2 | `ID_Str` | `access_card_id` | Display badge ID string | | 3 | `ACTIVATE` | `active_date_time` | Activation date | | 4 | `DEACTIVATE` | `expiry_date_time` | Expiry/deactivation date | | 5 | `STATUS` | `is_active` | 1 = active, other = inactive | | 6 | `PERSONID` | `user_id` | Associated cardholder | | 7 | `BadgeType.NAME` | `cardType` | Badge type name (from `Lnl_BadgeType`) | | 8 | `ID` | `card_id` | Numeric card ID | ### Event Logs Alarm acknowledgment events collected via SignalR in real time. | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | (generated) | `id` | UUID generated per event | | 2 | `eventType` | `name` | Event type from lookup map | | 3 | `deviceId` | `deviceId` | Associated device | | 4 | (derived) | `status` | Acknowledgment status | | 5 | `acknowledgeNotes` | `description` | Ack notes from operator | | 6 | `ALARM_ACKNOWLEDGEMENT` | `category` | Fixed category | | 7 | `timestamp` | `created_at` | Event timestamp (building TZ) | ### Polling Schedule * **Access Log** -- Real-time via SignalR; REST backup every 1 hour (min: 1 hour, max: 24 hours) * **Access Card** -- Daily REST poll (badge inventory backup) * **Alarm** -- REST poll every 1 hour (alarm definitions) * **Event Log** -- Real-time via SignalR For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time door access events (granted/denied) across all entry points for live security monitoring * Track credential lifecycle: activations, deactivations, and badge type classifications * Centralize alarm management with priority levels, instruction text, and acknowledgment audit trails * Correlate access patterns with occupancy and energy data for building optimization * Generate compliance reports with detailed audit trails for every access event ## Troubleshooting > [accordion] WebSocket/SignalR connection failed > > Verify the URL and credentials are correct. Ensure the OnGuard OpenAccess API is enabled and the `LENEL_API_KEY` environment variable is set correctly. Check that network firewalls allow WebSocket connections from the KODE OS server to the OnGuard host. > [accordion] Connector auto-deactivated > > The connector automatically deactivates on authentication failures to prevent account lockout. Common causes: expired password, invalid Application ID, or locked account. Fix the credentials and re-enable the connector from the Data Sources page. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. For SignalR data, verify the WebSocket connection is active. For REST data (badges, alarms), check that the OnGuard server is reachable and responding. Review error logs on the connector detail page. # Mirra Source: https://docs.kodelabs.com/products/integrations/access-control/mirra Connect Mirra to KODE OS for access control data > Connect Mirra to KODE OS for access control data integration ## Overview Use this integration to connect Mirra to KODE OS so you can synchronize access card and credential data with your C•CURE environment. REST and webhooks together keep cardholder and status information available in KODE OS for monitoring and downstream workflows. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Mirra](https://kodelabs.com/integration/mirra/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Mirra and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Mirra platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Mirra** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **CCure datasource ID** | No | text | Configuration field for CCure datasource ID | ## What Data You Get ### Access Cards Access card and credential records including cardholder information and card status ### Polling Schedule * **AccessCard** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Mirra platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Mirra platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Mirra system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Mirra API. # Open Options Flex Source: https://docs.kodelabs.com/products/integrations/access-control/openOptions Connect Open Options Flex to KODE OS for access control data > Connect Open Options Flex to KODE OS for access control data integration ## Overview Use this integration to connect your Open Options Flex access control system to KODE OS. You can discover devices and points and collect sensor and non-sensor access data through REST. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Open Options Flex](https://kodelabs.com/integration/open-options/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Open Options Flex and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Open Options Flex developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Open Options Flex developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Open Options Flex** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Open Options Flex system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Open Options Flex, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `isMasked` | **True** -- alarm is masked/suppressed / **False** -- alarm is not masked | -- | No | `medium_priority_alarm` | Polling | | 2 | `mode` | Current operating mode | -- | No | -- | Polling | | 3 | `active` | **True** -- door is currently open / **False** -- door is closed | -- | No | `door_status` | Polling | | 4 | `forcedOpen` | **True** -- door has been forced open / **False** -- no forced entry detected | -- | No | `high_priority_alarm` | Polling | | 5 | `forceMasked` | **True** -- forced-open alarm is masked / **False** -- forced-open alarm is active | -- | No | `high_priority_alarm` | Polling | | 6 | `heldOpen` | **True** -- door is being held open / **False** -- door is not held open | -- | No | `low_priority_alarm` | Polling | | 7 | `heldMasked` | **True** -- held-open alarm is masked / **False** -- held-open alarm is active | -- | No | `low_priority_alarm` | Polling | | 8 | `fault` | **True** -- fault condition detected / **False** -- no fault | -- | No | `medium_priority_alarm` | Polling | | 9 | `online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including isMasked, mode, active, forcedOpen, forceMasked, heldOpen, heldMasked, fault, and 1 more, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Open Options Flex data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `uniqueId` | -- | | **name** | `hardwareType` | -- | | **description** | `alarmDescription` | -- | | **priority** | `priority` | -- | | **status** | `status` | -- | | **deviceId** | `hardwareUniqueKey` | -- | | **deviceName** | `hardwareDescription` | -- | | **location** | `hardwareAddress` | -- | | **createdAt** | `transaction` | transformed | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **Alarm** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Open Options Flex developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Open Options Flex system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Open Options Flex API. # Avigilon Alta Source: https://docs.kodelabs.com/products/integrations/access-control/openPath Connect Avigilon Alta to KODE OS for access control data > Connect Avigilon Alta to KODE OS for access control data integration ## Overview Use this integration to connect your Avigilon Alta (formerly Openpath) access control system to KODE OS. You can discover ACUs, readers, locks, and related devices, then monitor status, alarms, and operational data from the platform. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Avigilon Alta](https://kodelabs.com/integration/avigilon-alta/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Avigilon Alta and access to their API or developer portal * Username and password credentials for the Avigilon Alta system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Avigilon Alta** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | No | text | The base URL or IP address of the external system | | **Username** | No | text | The username for authenticating with the external system | | **Password** | No | password | The password for authenticating with the external system | | **Organization ID** | No | password | Configuration field for Organization ID | | **API Building ID** | No | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Avigilon Alta system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Avigilon Alta, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `connectionStatus` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | | 2 | `temperature` | Current temperature reading (°C) | °C | No | Polling | | 3 | `is_virtual` | **True** -- is\_virtual is active / **False** -- is\_virtual is not active | -- | No | Polling | | 4 | `Status` | Current operating status | -- | No | Polling | | 5 | `entry_count` | Cumulative count of events | -- | No | Polling | | 6 | `offline_entry_count` | Cumulative count of events | -- | No | Polling | | 7 | `user_count` | Number of unique users | -- | No | Polling | | 8 | `group_count` | Number of groups | -- | No | Polling | | 9 | `Locked` | **True** -- access point is locked / **False** -- access point is unlocked | -- | No | Polling | | 10 | `fdr_active` | **True** -- fire door release is active / **False** -- fire door release is inactive | -- | No | Polling | | 11 | `current_lock_state` | Current state of the lock mechanism | -- | No | Polling | | 12 | `primary_battery_status` | Primary battery condition | -- | No | Polling | | 13 | `rtcc_status` | Real-time clock controller status | -- | No | Polling | | 14 | `comm_status` | Communication link status | -- | No | Polling | | 15 | `battery_level` | Device battery level | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including connectionStatus, temperature, is\_virtual, Status, entry\_count, offline\_entry\_count, user\_count, group\_count, and 7 more, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Avigilon Alta data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `idExt` | -- | | **name** | `eventName` | -- | | **description** | `note` | -- | | **priority** | `alarmSeverity.name` | -- | | **status** | `alarmStatus.name` | -- | | **deviceId** | `entryId` | -- | | **deviceName** | `entryName` | -- | | **updatedBy** | `userName` | -- | | **createdAt** | `createdAt` | -- | | **startedAt** | `firstAcknowledgedAt` | -- | | **completedAt** | `lastAcknowledgedAt` | -- | | **updatedAt** | `updatedAt` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **Alarm** -- Default polling: 1 hours (min: 1 hours, max: 1 days) * **Audit Log** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Avigilon Alta system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Avigilon Alta system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Avigilon Alta API. # Paxton Source: https://docs.kodelabs.com/products/integrations/access-control/paxton Connect Paxton to KODE OS for access control data > Connect Paxton to KODE OS for access control data integration ## Overview Use this integration to connect your Paxton Net2 access control system to KODE OS. You can discover door controllers and access points, then monitor device status and entry-related data from a centralized dashboard. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Paxton](https://kodelabs.com/integration/paxton/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points ## Prerequisites * An active account with Paxton and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Paxton developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Paxton developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Paxton** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Paxton system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Paxton, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `active` | **True** -- device is active / **False** -- device is inactive | -- | No | `controller_status` | Polling | | 2 | `isIntruderAlarmSet` | **True** -- medium-priority alarm is active / **False** -- no alarm | -- | No | `medium_priority_alarm` | Polling | | 3 | `isPSUOk` | **True** -- low-priority alarm is active / **False** -- no alarm | -- | No | `low_priority_alarm` | Polling | | 4 | `isTamperStatusGood` | **True** -- low-priority alarm is active / **False** -- no alarm | -- | No | `low_priority_alarm` | Polling | | 5 | `isDoorContactClosed` | **True** -- isDoorContactClosed is active / **False** -- isDoorContactClosed is not active | -- | No | -- | Polling | | 6 | `alarmTripped` | **True** -- high-priority alarm is active / **False** -- no alarm | -- | No | `high_priority_alarm` | Polling | | 7 | `doorStatus` | **True** -- door is open / **False** -- door is closed | -- | No | `door_status` | Polling | | 8 | `isACUAccessible` | **True** -- isACUAccessible is active / **False** -- isACUAccessible is not active | -- | No | -- | Polling | | 9 | `waitForValidAccess` | **True** -- waitForValidAccess is active / **False** -- waitForValidAccess is not active | -- | No | -- | Polling | | 10 | `soundFireAlarm` | Ambient sound level | -- | No | -- | Polling | | 11 | `silentOperation` | **True** -- silentOperation is active / **False** -- silentOperation is not active | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including active, isIntruderAlarmSet, isPSUOk, isTamperStatusGood, isDoorContactClosed, alarmTripped, doorStatus, isACUAccessible, and 3 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Paxton developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Paxton system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Paxton API. # Schneider Access Expert Source: https://docs.kodelabs.com/products/integrations/access-control/schneiderAccessXpert Connect Schneider Access Expert to KODE OS for access control data > Connect Schneider Access Expert to KODE OS for access control data integration ## Overview Use this integration to connect Schneider Access Expert (AccessXpert) to KODE OS. You can discover access devices and points, then monitor entries, exits, and access attempts for operations and reporting. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Schneider Access Expert](https://kodelabs.com/integration/accessxpert/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Schneider Access Expert and access to their API or developer portal * Username and password credentials for the Schneider Access Expert system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Schneider Access Expert** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Instance** | Yes | text | The instance name or number in the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Schneider Access Expert system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Schneider Access Expert, KODE OS maps them to the following device types and data points: ### Access Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `is_tampered` | **True** -- is\_tampered is active / **False** -- is\_tampered is not active | -- | No | Polling | | 2 | `door_forced_open` | **True** -- door has been forced open / **False** -- no forced entry detected | -- | No | Polling | | 3 | `mask_door_forced_open` | **True** -- door has been forced open / **False** -- no forced entry detected | -- | No | Polling | | 4 | `door_held_open` | **True** -- door is being held open / **False** -- door is not held open | -- | No | Polling | | 5 | `mask_door_held_open` | **True** -- door is being held open / **False** -- door is not held open | -- | No | Polling | | 6 | `door_contact_faulted` | **True** -- fault condition detected / **False** -- no fault | -- | No | Polling | | 7 | `rex_faulted` | **True** -- fault condition detected / **False** -- no fault | -- | No | Polling | | 8 | `latch_mode` | Current latch operating mode | -- | No | Polling | | 9 | `entry_delay` | Entry delay timer duration | -- | No | Polling | | 10 | `exit_delay` | Exit delay timer duration | -- | No | Polling | | 11 | `debounce` | Debounce timer setting | -- | No | Polling | | 12 | `behaviour` | Configured device behaviour | -- | No | Polling | | 13 | `hold_time` | Hold time duration setting | -- | No | Polling | | 14 | `is_disabled` | **True** -- device is disabled / **False** -- device is enabled | -- | No | Polling | | 15 | `is_online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 16 | `is_powered` | **True** -- is\_powered is active / **False** -- is\_powered is not active | -- | No | Polling | | 17 | `is_faulted` | **True** -- fault condition detected / **False** -- no fault | -- | No | Polling | | 18 | `is_battery_low` | **True** -- battery is OK / **False** -- battery needs attention | -- | No | Polling | | 19 | `mode` | Current operating mode | -- | No | Polling | | 20 | `activation_time` | Activation time duration | -- | No | Polling | | 21 | `is_activated` | **True** -- device is activated / **False** -- device is not activated | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including is\_tampered, door\_forced\_open, mask\_door\_forced\_open, door\_held\_open, mask\_door\_held\_open, door\_contact\_faulted, rex\_faulted, latch\_mode, and 13 more, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Schneider Access Expert data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | `key` | -- | | **name** | `messageShort` | -- | | **description** | `messageLong` | -- | | **deviceId** | `clientDeviceId` | -- | | **createdAt** | `occurredOn` | transformed | | **customFields** | `priority` | -- | ### Access Control Access control records including card reader events, credential verification, and zone access KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **AccessControl** -- Default polling: 5 minutes (min: 5 minutes, max: 5 minutes) * **EventLog** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Schneider Access Expert system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Schneider Access Expert system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Schneider Access Expert API. # Software House - C•Cure 9000 Source: https://docs.kodelabs.com/products/integrations/access-control/softwareHouse Connect Software House - C•Cure 9000 to KODE OS for access control data > Connect Software House - C•Cure 9000 to KODE OS for access control data integration ## Overview Use this integration to connect Software House C•CURE 9000 to KODE OS. You can discover devices and points, collect access and security sensor and non-sensor data, and run supported actions from KODE OS when your deployment exposes them. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Software House - C•Cure 9000](https://kodelabs.com/integration/software-house-ccure-9000/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * API Requests ## Prerequisites * An active account with Software House - C•Cure 9000 and access to their API or developer portal * API key or token from the Software House - C•Cure 9000 platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Software House - C•Cure 9000 platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Software House - C•Cure 9000** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Client Name** | Yes | text | The client application name registered with the vendor | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Client Version** | Yes | dropdown | The version of the vendor's API client | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Software House - C•Cure 9000 system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Visitor Logs Visitor registration and tracking records including visitor name, host, check-in/out times ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) * **Audit Log** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Register Visitor **Type:** Write Registers a new visitor in the Software House access control system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Type** | STRING | Yes | Text Box | -- | | **Visit Name** | STRING | Yes | Text Box | -- | | **Description** | STRING | No | Text Box | -- | | **Visit Site ID** | STRING | Yes | Text Box | -- | | **Visit Start** | DATE\_TIME | Yes | Text Box | -- | | **Visit End** | DATE\_TIME | Yes | Text Box | -- | | **Personnel ID** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "type": "example-value", "visitName": "example-value", "visitSiteId": "12345", "visitStart": "2026-03-29T10:00:00Z", "visitEnd": "2026-03-29T10:00:00Z", "childrenPersonnelId": "12345", "description": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Register Visit **Type:** Write Registers a new visit record in Software House | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Type** | STRING | Yes | Text Box | -- | | **Name** | STRING | Yes | Text Box | -- | | **Hosting Mode** | STRING | Yes | Text Box | -- | | **Partition** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "type": "example-value", "name": "example-value", "hostingMode": "example-value", "partition": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Delete Visit **Type:** Write Deletes a visit record from Software House | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Type** | STRING | Yes | Text Box | -- | | **Visit ID** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "type": "example-value", "id": "12345" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Get All Registered Visitors **Type:** Read Retrieves all registered visitors for a site | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Type** | STRING | Yes | Text Box | -- | | **Visit Site ID** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "type": "example-value", "visitSiteId": "12345" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Software House - C•Cure 9000 platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Software House - C•Cure 9000 system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Software House - C•Cure 9000 API. # Swift Connect Source: https://docs.kodelabs.com/products/integrations/access-control/swiftConnect Connect Swift Connect to KODE OS for access control data > Connect Swift Connect to KODE OS for access control data integration ## Overview Use this integration to connect SwiftConnect to KODE OS. You can discover access hardware and points, collect sensor and non-sensor data, and pull historical access information alongside mobile-credential flows such as phone-based access. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Swift Connect](https://kodelabs.com/integration/swift-connect/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Swift Connect and access to their API or developer portal * Username and password credentials for the Swift Connect system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Swift Connect** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Base ID** | Yes | text | The base identifier for the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Profiles Base Id** | No | text | Configuration field for Profiles Base Id | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Swift Connect system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Swift Connect, KODE OS maps them to the following device types and data points: ### IO Reader / Controller Canonical Type: `IOREADER` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `connection_status` | Device connectivity status | -- | No | `connection_status` | Polling | ## What Data You Get ### Point History Time-series readings including connection\_status, collected at regular intervals from connected devices ### Access Events Mobile access events including credential presentation and door access results ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 15 minutes) * **SwiftConnectEvent** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Swift Connect system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Swift Connect system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Swift Connect API. # Zerv Source: https://docs.kodelabs.com/products/integrations/access-control/zerv Connect Zerv to KODE OS for access control data > Connect Zerv to KODE OS for access control data integration ## Overview Use this integration to connect Zerv smart-lock and reader environments to KODE OS. You can discover devices and points, then monitor access status, mobile credentials, and related operational data across your sites. | Property | Value | | - | - | | **System Type** | Access Control | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Zerv and access to their API or developer portal * Username and password credentials for the Zerv system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Zerv** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Zerv system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Zerv, KODE OS maps them to the following device types and data points: ### doorLock Canonical Type: `doorLock` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Active` | **True** -- device is active / **False** -- device is inactive | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Active, collected at regular intervals from connected devices ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) * **Audit Log** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize access event monitoring across all entry points and zones * Generate audit trails for security compliance and investigation * Correlate access patterns with occupancy and energy data for building optimization ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Zerv system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Zerv system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Zerv API. # Armis Source: https://docs.kodelabs.com/products/integrations/asset-management/armis Connect Armis to KODE OS for asset data > Connect Armis to KODE OS for asset data integration ## Overview Use this integration to connect Armis asset inventory to KODE OS. You discover devices and IT/OT assets over REST for unified visibility alongside building systems. | Property | Value | | - | - | | **System Type** | Asset | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Discover Assets ## Prerequisites * An active account with Armis and access to their API or developer portal * API key or token from the Armis platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Armis platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Armis** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Site ID** | Yes | text | The site identifier in the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Armis system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Armis data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `alertId` | -- | | **name** | `type` | -- | | **description** | `description` | -- | | **priority** | `severity` | -- | | **status** | `status` | -- | | **createdAt** | `time` | -- | | **updatedAt** | `lastAlertUpdateTime` | -- | | **customFields** | `(custom fields)` | custom fields object | | **deviceId** | mapped by connector | -- | | **deviceId** | mapped by connector | conditional | ### Polling Schedule * **Asset** -- Default polling: 5 minutes (min: 5 minutes, max: 30 minutes) * **Alarm** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Armis data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Armis platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Armis system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Armis API. # Arkiv CCTV Source: https://docs.kodelabs.com/products/integrations/cameras/arkiv Connect Arkiv CCTV to KODE OS for camera, video data > Connect Arkiv CCTV to KODE OS for camera, video data integration ## Overview Use this integration to connect Arkiv CCTV to KODE OS. You can discover cameras and video devices, stream video, and collect sensor and non-sensor telemetry alongside alarms and events from your Arkiv deployment. | Property | Value | | - | - | | **System Type** | Camera, Video | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Video Streaming ## Prerequisites * An active account with Arkiv CCTV and access to their API or developer portal * Username and password credentials for the Arkiv CCTV system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Arkiv CCTV** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Arkiv CCTV system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Arkiv CCTV, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `isActivated` | **True** -- device is activated / **False** -- device is not activated | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including isActivated, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Arkiv CCTV data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **deviceName** | `displayName` | -- | | **deviceId** | `displayId` | -- | | **createdAt** | `timestamp` | transformed | | **description** | `type` | -- | | **customFields** | `(custom fields)` | -- | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **EventLog** * **Alarm** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds * Integrate video surveillance feeds into the building operations dashboard ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Arkiv CCTV system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Arkiv CCTV system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Arkiv CCTV API. # Ava Cameras Source: https://docs.kodelabs.com/products/integrations/cameras/avaCameras Connect Ava Cameras to KODE OS for camera data > Connect Ava Cameras to KODE OS for camera data integration ## Overview Use this integration to connect Ava Cameras to KODE OS. You can discover cameras and data points, then monitor status and collect sensor and non-sensor data for building and security operations. | Property | Value | | - | - | | **System Type** | Camera | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Ava Cameras](https://kodelabs.com/integration/ava-cameras/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Ava Cameras and access to their API or developer portal * Username and password credentials for the Ava Cameras system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Ava Cameras** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Ava Cameras system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Ava Cameras, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Active` | **True** -- camera is active and streaming / **False** -- camera is inactive | -- | No | `connection_status` | Polling | | 2 | `Status` | Current operating status | -- | No | `run_status` | Polling | ## What Data You Get ### Point History Time-series readings including Active, Status, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Ava Cameras data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **name** | `alertType` | -- | | **description** | `description` | -- | | **priority** | `systemRuleImportance` | -- | | **status** | `resolution` | -- | | **deviceId** | `deviceId` | -- | | **updatedBy** | `userId` | -- | | **createdAt** | `startDate.t2` | transformed | | **completedAt** | `endDate.t2` | transformed | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 30 minutes) * **Alarm** -- Default polling: 1 hours (min: 1 hours, max: 3 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Ava Cameras system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Ava Cameras system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Ava Cameras API. # Avigilon ACC (Avigilon Control Center) Source: https://docs.kodelabs.com/products/integrations/cameras/avigilon Connect Avigilon ACC (Avigilon Control Center) to KODE OS for camera, video data > Connect Avigilon ACC (Avigilon Control Center) to KODE OS for camera, video data integration ## Overview Use this integration to connect Avigilon Control Center (ACC) to KODE OS. You can discover cameras and devices, receive webhook events, stream video, and collect camera and video telemetry through REST. | Property | Value | | - | - | | **System Type** | Camera, Video | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Avigilon ACC (Avigilon Control Center)](https://kodelabs.com/integration/aviglion-cctv/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * Video Streaming ## Prerequisites * An active account with Avigilon ACC (Avigilon Control Center) and access to their API or developer portal * Username and password credentials for the Avigilon ACC (Avigilon Control Center) system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Avigilon ACC (Avigilon Control Center) platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Avigilon ACC (Avigilon Control Center)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **User Nonce** | Yes | password | The user nonce value for authentication | | **User Key** | Yes | password | The user-specific key from the vendor platform | | **Client Name** | Yes | password | The client application name registered with the vendor | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Avigilon ACC (Avigilon Control Center) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Avigilon ACC (Avigilon Control Center), KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Active` | **True** -- camera is active and streaming / **False** -- camera is inactive | -- | No | `run_status` | Webhook | | 2 | `Connected` | Device connectivity status | -- | No | `connection_status` | Webhook | ## What Data You Get ### Point History Time-series readings including Active, Connected, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Avigilon ACC (Avigilon Control Center) data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **category** | mapped by connector | -- | | **customFields** | `(custom fields)` | custom fields object | | **name** | `event.activity` | -- | | **description** | `event.analyticEventName` | -- | | **location** | `event.location` | -- | | **deviceId** | `event.cameraId` | -- | | **status** | `event.type` | -- | | **createdAt** | `event.timestamp` | transformed | | **createdAt** | `time` | transformed | | **name** | `event.activity` | conditional | | **createdAt** | `time` | conditional | ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) * **EventLog** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds * Integrate video surveillance feeds into the building operations dashboard ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Avigilon ACC (Avigilon Control Center) system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Avigilon ACC (Avigilon Control Center) platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Avigilon ACC (Avigilon Control Center) system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Avigilon ACC (Avigilon Control Center) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Avigilon ACC (Avigilon Control Center) API. # Axis CCTV Source: https://docs.kodelabs.com/products/integrations/cameras/axis Connect Axis CCTV to KODE OS for camera, video data > Connect Axis CCTV to KODE OS for camera, video data integration ## Overview Use this integration to connect Axis CCTV to KODE OS. You can discover cameras and encoders, stream video, and collect sensor and non-sensor data for monitoring and incident response. | Property | Value | | - | - | | **System Type** | Camera, Video | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Axis CCTV](https://kodelabs.com/integration/axis-communications/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Video Streaming ## Prerequisites * An active account with Axis CCTV and access to their API or developer portal * Username and password credentials for the Axis CCTV system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Axis CCTV** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Axis CCTV system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Axis CCTV, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | Current operating status | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Axis CCTV data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | generated ID | -- | | **name** | `eventLogType` | -- | | **createdAt** | timestamp (UTC) | -- | | **deviceId** | `data.cameraId` | -- | | **deviceName** | `data.name` | -- | | **deviceId** | `data.cameraId` | conditional | | **deviceName** | `data.name` | conditional | ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique alarm identifier | | **Name** | Alarm name or title | | **Description** | Detailed alarm description | | **Category** | Alarm category (e.g., Building Automation, Security, Fire) | | **Priority** | Alarm priority or severity level | | **Status** | Current alarm state (e.g., Active, Acknowledged, Cleared) | | **Device ID** | ID of the device that generated the alarm | | **Device Name** | Name of the device that generated the alarm | | **Location** | Physical location of the alarm source | | **Updated By** | Person who last updated the alarm | | **Created At** | Timestamp when the alarm was generated | | **Started At** | Timestamp when the alarm condition started | | **Cleared At** | Timestamp when the alarm was cleared or resolved | | **Updated At** | Timestamp of the last alarm state change | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **EventLog** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Alarm** -- Default polling: 5 minutes (min: 5 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds * Integrate video surveillance feeds into the building operations dashboard ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Axis CCTV system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Axis CCTV system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Axis CCTV API. # Digital Watchdog Source: https://docs.kodelabs.com/products/integrations/cameras/digitalWatchdog Connect Digital Watchdog to KODE OS for camera, video data > Connect Digital Watchdog to KODE OS for camera, video data integration ## Overview Use this integration to connect Digital Watchdog to KODE OS. You can discover video devices and points, stream video, and receive push-based sensor data for real-time awareness. | Property | Value | | - | - | | **System Type** | Camera, Video | | **Communication** | REST | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Digital Watchdog](https://kodelabs.com/integration/digital-watchdog/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Video Streaming ## Prerequisites * An active account with Digital Watchdog and access to their API or developer portal * Username and password credentials for the Digital Watchdog system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Digital Watchdog** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | No | text | The base URL or IP address of the external system | | **Username** | No | text | The username for authenticating with the external system | | **Password** | No | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Digital Watchdog system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Digital Watchdog, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | **True** -- camera is online / **False** -- camera is offline | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 3 minutes (min: 3 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds * Integrate video surveillance feeds into the building operations dashboard ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Digital Watchdog system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Digital Watchdog system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Digital Watchdog API. # Exacq Vision Source: https://docs.kodelabs.com/products/integrations/cameras/exacqVision Connect Exacq Vision to KODE OS for camera data > Connect Exacq Vision to KODE OS for camera data integration ## Overview Use this integration to connect Exacq Vision to KODE OS. You can discover cameras and devices, then align live and recorded video context, camera health, and security-related events with your building data through the ExacqVision API. | Property | Value | | - | - | | **System Type** | Camera | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Exacq Vision](https://kodelabs.com/integration/exacqvision/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Exacq Vision and access to their API or developer portal * Username and password credentials for the Exacq Vision system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Exacq Vision** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Server ID** | Yes | text | The server identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Exacq Vision system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Exacq Vision, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `disabled` | Whether the device is disabled | -- | No | `connection_status` | Polling | | 2 | `motion` | **True** -- motion detected / **False** -- no motion detected | -- | No | -- | Polling | | 3 | `loss` | **True** -- signal or video loss detected / **False** -- signal is normal | -- | No | -- | Polling | | 4 | `state` | Current camera operating state | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including disabled, motion, loss, state, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique event identifier | | **Name** | Event name or title | | **Description** | Event details and context | | **Status** | Event status | | **Type** | Event type classification | | **Category** | Event category | | **Location** | Location where the event occurred | | **Device ID** | ID of the device that generated the event | | **Device Name** | Name of the device that generated the event | | **Created At** | Timestamp when the event occurred | | **Updated At** | Timestamp of the last event update | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **EventLog** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Exacq Vision system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Exacq Vision system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Exacq Vision API. # Genetec Security Center Source: https://docs.kodelabs.com/products/integrations/cameras/genetec Connect Genetec Security Center to KODE OS for camera data > Connect Genetec Security Center to KODE OS for camera data integration ## Overview Use this integration to connect Genetec Security Center to KODE OS. You can discover cameras and security devices, then collect sensor and non-sensor video and security data for centralized visibility. | Property | Value | | - | - | | **System Type** | Camera | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Genetec Security Center](https://kodelabs.com/integration/genetec-security-center/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Genetec Security Center and access to their API or developer portal * API key or token from the Genetec Security Center platform * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Genetec developer portal](https://developer.genetec.com/) * [Genetec technical docs hub](https://techdocs.genetec.com/) ## Generate API Credentials 1. Log in to the Genetec Security Center platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Genetec Security Center** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Device Types** | No | text | The device types to discover from the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Genetec Security Center system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Genetec Security Center, KODE OS maps them to the following device types and data points: ### IO Reader / Controller Canonical Type: `IOREADER` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `runningState` | Current run state of the controller | -- | No | `run_status` | Polling | | 2 | `online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | `connection_status` | Polling | | 3 | `locked` | **True** -- access point is locked / **False** -- access point is unlocked | -- | No | `lock_status` | Polling | | 4 | `open` | **True** -- door is open / **False** -- door is closed | -- | No | `door_status` | Polling | ## What Data You Get ### Point History Time-series readings including runningState, online, locked, open, collected at regular intervals from connected devices ### Security Alarms Genetec security system alarms including intrusion alerts, door forced events, and camera triggers ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Genetec Security Center data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | generated ID | -- | | **name** | event type | -- | | **description** | `message` | -- | | **deviceId** | `deviceGuid` | -- | | **createdAt** | `timestamp` | -- | | **customFields** | `(custom fields)` | custom fields object | | **category** | mapped by connector | -- | | **id** | `guid` | -- | | **name** | `title` | -- | | **description** | `note` | -- | | **createdAt** | `timestamp` | -- | | **updatedAt** | `updatedAt` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **GenetecAlarms** -- Default polling: 3 hours (min: 3 hours, max: 1 days) * **EventLog** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Genetec Security Center platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Genetec Security Center system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Genetec Security Center API. # Milestone Source: https://docs.kodelabs.com/products/integrations/cameras/milestone Connect Milestone to KODE OS for camera data > Connect Milestone to KODE OS for camera data integration ## Overview Use this integration to connect Milestone XProtect to KODE OS. You can discover cameras and points, then collect sensor and non-sensor video data for monitoring, investigations, and integrations. | Property | Value | | - | - | | **System Type** | Camera | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Milestone](https://kodelabs.com/integration/milestone/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Milestone and access to their API or developer portal * Username and password credentials for the Milestone system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Milestone** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Version** | Yes | dropdown | The API or firmware version to use | | **URL** | Yes | text | The base URL or IP address of the external system | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Milestone system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Milestone, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | `run_status` | Polling | ## What Data You Get ### Point History Time-series readings including Online, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Milestone data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `eventHeader.id` | -- | | **name** | `eventHeader.type` | -- | | **description** | `eventHeader.message` | -- | | **priority** | `eventHeader.priorityName` | -- | | **deviceId** | `eventHeader.source.fqid.objectId` | -- | | **deviceName** | `(formatted)` | -- | | **createdAt** | `timestamp` | -- | | **updatedAt** | `timestamp` | -- | | **deviceId** | `eventHeader.source.fqid.objectId` | conditional | | **deviceName** | `(formatted)` | conditional | | **createdAt** | `timestamp` | conditional | ### Polling Schedule * **Point History** -- Default polling: 2 minutes (min: 2 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Milestone system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Milestone system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Milestone API. # Salient Source: https://docs.kodelabs.com/products/integrations/cameras/salient Connect Salient to KODE OS for camera, video frames data > Connect Salient to KODE OS for camera, video frames data integration ## Overview Use this integration to connect Salient to KODE OS. You can discover cameras and devices and use video streaming so live views and frame-oriented video data stay available alongside your building data. | Property | Value | | - | - | | **System Type** | Camera, Video Frames | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Salient](https://kodelabs.com/integration/salient/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Video Streaming ## Prerequisites * An active account with Salient and access to their API or developer portal * Username and password credentials for the Salient system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Salient** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Salient system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Salient, KODE OS maps them to the following device types and data points: ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `state` | Current camera operating state | -- | No | `run_status` | Polling | ## What Data You Get ### Point History Time-series readings including state, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Salient data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | generated ID | -- | | **name** | `eventTypeName` | -- | | **description** | `description` | -- | | **deviceId** | `camera` | -- | | **createdAt** | `time` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **EventLog** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Integrate video surveillance feeds into the building operations dashboard * Correlate camera events with access control and alarm data for incident review * Monitor high-traffic areas and verify occupancy data against video feeds ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Salient system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Salient system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Salient API. # Actions Source: https://docs.kodelabs.com/products/integrations/capabilities/actions Send commands and make changes to devices and external systems through KODE OS > Send commands and make changes to devices and external systems through KODE OS Actions let you send commands to devices or make changes in external systems from KODE OS. Data collection reads from external systems. Actions write back — setting values, triggering commands, creating records, and managing schedules. ## Types of actions ### Point actions Point actions change a device's behavior by writing a new value to one of its data points. These are the most common type of action. **Examples**: * Set a thermostat temperature setpoint to 22°C * Turn a light on or off * Override a damper position for two hours * Acknowledge an alarm Point actions are defined per integration and per entity type. Each action specifies: | Property | Description | | - | - | | **Action type** | The kind of operation (for example, `WRITE`, `OVERRIDE`, `RELEASE`) | | **Display name** | The user-facing name in the UI (for example, Set Value or Ack Alarm) | | **Target entity** | Which entity type the action applies to (for example, Points or Alarms) | ### Entity actions Entity actions create or update records in external systems rather than controlling physical devices. **Examples**: * Create a work order in a CMMS (computerized maintenance management system) such as Corrigo or ServiceChannel * Push an event to a notification system * Update a reservation in a booking system ### Schedule actions Schedule actions manage time-based configurations in external systems. These are available for integrations that support schedule management. **Examples**: * Create a new weekly schedule in a Niagara controller * Update an existing calendar schedule's date range * Delete a temporary override schedule * Sync schedule references between KODE OS and the controller See the [Schedules guide](/products/integrations/capabilities/schedules). ## How actions work ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} sequenceDiagram participant User participant KODE as KODE OS participant Vendor as External System User->>KODE: Initiate action (e.g., set temp to 22°C) KODE->>KODE: Validate action fields KODE->>Vendor: Send command via API Vendor-->>KODE: Confirm or reject KODE-->>User: Show result ``` 1. **You initiate** the action from the device detail page, point explorer, or schedule manager 2. **KODE OS validates** the action parameters against the integration's requirements 3. **KODE OS sends** the command to the external system using the appropriate protocol 4. **The external system confirms** or rejects the action 5. **KODE OS shows** the result back to you ## Action availability Not all integrations support actions. Availability depends on: * **The external system's API**: The vendor must expose write or command endpoints * **The protocol**: REST, SOAP, and SDK integrations most often support actions. Webhook-only and MQTT integrations may have limited or no action support * **The entity type**: An integration might support point writes but not alarm acknowledgment, or the reverse Check the specific integration page for available actions. Browse the [Integrations catalog](/products/integrations/catalog) and open a vendor page to see its Actions section when present. ## Troubleshooting > [accordion] Action fails with permission error > > Verify that the API credentials configured in the connector have write permissions in the external system. Many vendor APIs use separate read-only and read-write API keys or roles. > [accordion] Action succeeds but value doesn't change > > Some external systems queue commands rather than applying them immediately. Check the external system's command queue or history. The device may also have a local override that takes precedence over remote commands. > [accordion] Action type not available for a device > > Not all devices within an integration support all action types. Available actions depend on the device type and the external system's capabilities. If a specific action is missing, verify that the device's firmware supports the command. # Data collection Source: https://docs.kodelabs.com/products/integrations/capabilities/data-collection How KODE OS collects sensor and non-sensor data from connected systems > How KODE OS collects sensor and non-sensor data from your connected systems Data collection is the continuous process of gathering data from connected external systems. Once devices and points are discovered and registered, KODE OS begins collecting their data according to configured schedules and protocols. ## Collection methods KODE OS supports two primary collection methods. The method depends on the integration's communication protocol and the external system's capabilities. ### Scheduled pull (polling) KODE OS periodically connects to the external system to request the latest data. The polling interval is configurable per connector and per entity type. ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} sequenceDiagram participant KODE as KODE OS participant Vendor as External System loop Every polling interval KODE->>Vendor: Request latest data Vendor-->>KODE: Return data payload KODE->>KODE: Process and store end ``` **Protocols used**: REST, SOAP, SDK, OpenSSL/TCP, SFTP/FTP, Modbus/BACnet Each integration defines default, minimum, and maximum polling intervals for its entity types. You can adjust the interval within the allowed range from the connector's entity configuration. ### Real-time push The external system sends data to KODE OS when events occur, without KODE OS asking for it. ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} sequenceDiagram participant Vendor as External System participant KODE as KODE OS Vendor->>KODE: Event occurs, push data KODE->>KODE: Process and store Vendor->>KODE: Another event, push data KODE->>KODE: Process and store ``` **Protocols used**: Webhooks, MQTT, WebSocket Push-based integrations receive data as soon as it is available, which lowers latency compared to polling. The external system must send data to the correct KODE OS endpoint. ### Hybrid Some integrations support both pull and push. For example, an integration might use webhooks for real-time point history and polling for periodic alarm collection. ## Collection modes The collection mode determines how KODE OS interprets the data it receives. Each integration entity uses one of three modes: ### Snapshot A single view of the current state at a specific moment. Each collection cycle captures the full current value of all points. **Use case**: Occupancy counts, current temperature readings, door status ### Delta Only changes since the last collection are reported. KODE OS stores the differences between polls. **Use case**: Controller data from BMS systems such as Niagara, where only changed values need to transfer ### Historical A complete log of past values over a time range. The external system provides timestamped historical data, which KODE OS ingests in bulk. **Use case**: Historical backfill, energy meter readings, audit logs ## Data types ### Sensor data Time-series data from physical sensors on devices. These are measurable, often timestamped values from device points. | Entity | Description | Example | | - | - | - | | **Point History** | Time-series sensor readings | Temperature: 22.5°C at 14:30 | ### Non-sensor data Structured data from external systems that is not generated by a physical sensor but matters for building operations. | Entity | Description | Example | | - | - | - | | **Alarm** | Alert or fault notifications | "High temperature alarm on AHU-1" | | **Audit Log** | Access and security event records | "Badge swipe at Main Entrance at 08:15" | | **Work Order** | Maintenance task records | "Replace filter on RTU-3, due 2026-04-01" | | **Booking** | Space reservation records | "Conference Room A booked 10:00-11:00" | | **EV Charging** | Charging session records | "Station 5: 45 kWh delivered, session complete" | | **Schedule Sync** | Schedule state synchronization | "Weekday schedule active on AHU-2" | ## Polling intervals Each integration defines its polling schedule with three parameters: | Parameter | Description | | - | - | | **Default interval** | Recommended polling frequency for the entity | | **Minimum interval** | Fastest allowed polling frequency (avoids API rate limits) | | **Maximum interval** | Slowest allowed polling frequency | Polling intervals are configured per entity type within a connector. For example, a Niagara connector might poll point history every 30 seconds but alarms every five minutes. > [!WARNING] > > Setting polling intervals below the minimum can cause rate limiting or authentication failures with the external system. Always stay within the allowed range. ## Collection status You can monitor collection status for each connector from the `Data Sources` page. Status indicators show: * **Up / Active**: Data is collecting successfully on schedule * **Down / Error**: The last collection attempt failed — check the connector logs * **Paused**: Collection has been manually paused * **Disconnected**: The connector cannot reach the external system Connector detail pages often show Up or Down for overall health. Entity and collection views may also use Active, Error, Paused, or Disconnected. Treat Up with Active, and Down with Error or Disconnected, as the same health signal in different parts of the UI. ## Troubleshooting > [accordion] Data is not being collected > > First, verify the connector shows a successful test connection. Then check that the entities are enabled and the polling interval is configured. If the external system requires re-authentication (for example, expired OAuth tokens), update the connector credentials. > [accordion] Data appears delayed > > For pull-based integrations, data freshness depends on the polling interval. If you need more frequent updates, reduce the polling interval within the allowed minimum. For push-based integrations, verify that the external system's webhook or MQTT configuration points to the correct KODE OS endpoint. > [accordion] Duplicate data points > > Some integrations may deliver the same data across overlapping collection cycles. KODE OS deduplicates data based on the point identifier and timestamp. If you see duplicates, check whether the connector's collection mode matches the external system's behavior (snapshot vs. delta). # Discovery Source: https://docs.kodelabs.com/products/integrations/capabilities/discovery Automatically find devices, points, schedules, and assets from connected systems > Automatically find devices, points, schedules, and assets from your connected systems Discovery is the process of querying a connected external system to find and register available entities — devices, data points, schedules, and assets — without configuring each item by hand. ## How discovery works When you run discovery on a connector, KODE OS queries the external system's API for available entities. ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} flowchart TD A["User triggers discovery"] --> B["KODE OS authenticates with external system"] B --> C["Query external API for available entities"] C --> D["Parse and normalize discovered items"] D --> E["Present results to user"] E --> F["User selects items to register"] F --> G["Items saved to KODE OS"] ``` > [!NOTE] > > Not all integrations support discovery. Check the specific integration page to see if discovery is available. Integrations that only receive data via webhooks or MQTT typically do not have a discovery step. ## What gets discovered ### Devices A device represents physical hardware or a logical grouping in the external system — a thermostat, sensor hub, door controller, meter, or camera. Each discovered device includes: | Field | Description | | - | - | | **External ID** | Unique identifier of the device in the external system | | **Name** | Device name as reported by the external system | | **Type** | Category or model of the device | | **Location** | Physical location metadata if available from the vendor | | **Labels** | Tags or categories from the external system | Discovery results can include hardware and network metadata when the connector provides it. That metadata can include manufacturer, model, firmware version, OS version, MAC address, and IP address. ### Points Points are the individual data values or control endpoints on a device. For a thermostat, points might include current temperature, setpoint, humidity, and operating mode. Each discovered point includes: | Field | Description | | - | - | | **External ID** | Unique identifier of the point in the external system | | **Name** | Point name as reported by the external system | | **Unit** | Unit of measurement (for example, °C, %, kWh) | | **Type** | Whether this is a sensor reading, a command, or a status | | **Labels** | Tags or categories from the external system | ### Schedules For integrations that support schedule management (for example, Niagara or Distech), KODE OS can discover schedules already configured in the external system. Discovered schedules include name, type (weekly or calendar), current values, and linked point references. See the [Schedules guide](/products/integrations/capabilities/schedules). ### Assets Assets are physical or virtual objects that KODE OS tracks for metadata. Unlike devices, they do not have time-series data points. Asset discovery is available for integrations that manage inventory-type data. Examples of assets: * Network equipment (routers, switches, servers) * Furniture (desks, chairs, whiteboards) * Safety equipment (fire extinguishers, AEDs) * Any physical item that needs metadata tracking ## Running discovery **1. Open the connector** Go to `Data Sources` in your building, then select the connector you want to discover from. **2. Start discovery** Click `Discover` on the connector detail page. KODE OS authenticates with the external system and queries for available entities. **3. Review results** Discovery results list found devices and their points. Each item shows: * Device or point name * External system identifier * Type and category * Whether it is new or already registered **4. Select and register** Select the devices and points you want to register in KODE OS. You can select individual items or use Select All for bulk registration. Registered devices and points become available for data collection across the platform. ## Discovery behavior by protocol | Protocol | Discovery method | | - | - | | **REST / SOAP** | KODE OS calls the vendor's list or query endpoints to enumerate devices and points | | **Modbus / BACnet** | KODE OS scans the network or queries the controller's object list | | **MQTT** | Discovery is typically not available — devices register by publishing to known topics | | **Webhook** | Discovery is typically not available — data arrives as push notifications | | **SDK** | KODE OS uses the vendor's SDK methods to list available entities | ## Rediscovery You can run discovery multiple times on the same connector. When you rediscover: * **New items** appear as available for registration * **Existing items** appear as already registered and can be updated * **Removed items** (no longer found in the external system) are flagged for review ## Troubleshooting > [accordion] Discovery returns no devices > > Verify that the connector credentials have the correct permissions in the external system. Some vendor APIs require specific roles or scopes to list devices. Also check that the URL and authentication settings are correct by running a test connection first. > [accordion] Discovery times out > > Large systems with thousands of devices may take longer to discover. If discovery times out, try narrowing the scope by configuring a specific folder, site, or building filter in the connector settings when the integration supports it. > [accordion] Discovered devices are missing points > > Some integrations discover devices and points in separate steps. After registering devices, you may need to run discovery again or open the device detail page to see its points. Also verify that the external system's API exposes point-level data. # MQTT integrations Source: https://docs.kodelabs.com/products/integrations/capabilities/mqtt How KODE OS receives real-time data from MQTT-based devices and systems > How KODE OS receives real-time data from MQTT-based devices and systems MQTT (Message Queuing Telemetry Transport) is a lightweight messaging protocol designed for constrained devices and low-bandwidth networks. KODE OS uses MQTT to receive real-time data from IoT devices, sensors, and building systems that publish messages to MQTT brokers. ## How MQTT works MQTT uses a publish/subscribe model. Devices publish messages to topics on an MQTT broker instead of connecting directly to KODE OS. KODE OS subscribes to those topics and processes incoming messages as they arrive. ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} flowchart LR D1["Device 1"] -->|"publish"| Broker["MQTT broker"] D2["Device 2"] -->|"publish"| Broker D3["Device 3"] -->|"publish"| Broker Broker -->|"subscribe"| KODE["KODE OS"] ``` ### Key concepts | Concept | Description | | - | - | | **Broker** | Central server that receives published messages and forwards them to subscribers | | **Topic** | Hierarchical string that categorizes messages (for example, `building/floor1/sensor/temperature`) | | **Publish** | A device sends a message to a specific topic on the broker | | **Subscribe** | KODE OS registers interest in specific topics to receive their messages | | **QoS** | Quality of Service level (0 = at most once, 1 = at least once, 2 = exactly once) | ## MQTT vs. polling Unlike REST-based integrations where KODE OS polls for data at intervals, MQTT delivers data as soon as the device publishes it. This results in: * **Lower latency**: Data arrives in milliseconds rather than waiting for the next polling interval * **Reduced bandwidth**: Only changed values are transmitted, rather than full data snapshots * **Better scalability**: The broker handles routing, so thousands of devices can publish at once ## MQTT connector configuration MQTT integrations in KODE OS typically require the following configuration: | Field | Description | | - | - | | **Host** | MQTT broker hostname or IP address | | **Port** | Broker port (default: 1883 for TCP, 8883 for TLS) | | **Username / Password** | Credentials for authenticating with the broker | | **Telemetry topic** | Topic pattern where devices publish sensor data | | **Metadata topic** | Topic pattern where devices publish device metadata | | **Command topic** | Topic for sending commands back to devices when actions are supported | Some MQTT integrations use additional topic configurations for schedules, status updates, or discovery. ## Topic structure MQTT topics are hierarchical strings separated by forward slashes. The exact structure depends on the integration and the device manufacturer. **Common patterns**: * `{building}/{floor}/{device}/telemetry` — Sensor data from a specific device * `{building}/+/+/metadata` — Metadata from all devices (using the `+` wildcard) * `{building}/#` — All messages from a building (using the `#` wildcard) Wildcards: * `+` matches a single level (for example, `building/+/temperature` matches `building/floor1/temperature` and `building/floor2/temperature`) * `#` matches all remaining levels (for example, `building/#` matches everything under `building/`) ## Security Secure MQTT connections with TLS encryption (port 8883) whenever possible. KODE OS supports: * **Username and password authentication** for basic broker access * **TLS certificates** for encrypted connections * **Client certificates** for mutual TLS authentication where required ## MQTT integrations in KODE OS Several integrations use MQTT as their primary communication method: * **KODE MQTT** — Generic MQTT connector for custom device integrations * **EnOcean** — Wireless sensor protocol bridged via MQTT * **CloudGate** — IoT gateway that publishes device data via MQTT * Other integrations that support MQTT as an alternative to REST polling Check each integration's page for MQTT configuration requirements and topic structure details. MQTT connectors usually receive data as it arrives and often do not use a discovery step. See the [Discovery guide](/products/integrations/capabilities/discovery) for protocol-specific behavior. ## Troubleshooting > [accordion] No data is being received > > Verify the MQTT broker is reachable from KODE OS. Check that topic subscriptions match the topics devices publish to — MQTT topics are case-sensitive and must match exactly. Confirm that broker credentials are correct and the user has subscribe permissions. > [accordion] Intermittent data gaps > > Check the QoS level on both the publisher (device) and subscriber (KODE OS). QoS 0 allows messages to be lost if the connection is unstable. Consider QoS 1 or 2 for more reliable delivery. Also verify that the MQTT broker is not overloaded or rate-limiting connections. > [accordion] Cannot send commands to devices > > Verify that the command topic is correctly configured and that the KODE OS MQTT client has publish permissions on that topic. Some MQTT brokers restrict publish access by authenticated user ACL. # Schedules Source: https://docs.kodelabs.com/products/integrations/capabilities/schedules Discover and manage time-based schedules in connected building systems > Discover and manage time-based schedules in connected building systems Schedules define how devices behave over time — when HVAC systems turn on, when lights dim, and when access doors lock. For integrations that support schedule management, KODE OS lets you discover, create, update, and delete schedules directly in the external system. ## Schedule types KODE OS supports two types of schedules. ### Weekly schedules Weekly schedules define recurring routines for each day of the week. They are the foundation for regular building operations. **Example**: An HVAC system runs in Occupied mode Monday through Friday from 6 AM to 8 PM, and switches to Unoccupied mode during evenings and weekends. Weekly schedules can contain: * A single value per time slot (for example, a temperature setpoint or an on/off state) * Different values for each day of the week * Special event overrides that temporarily change the normal pattern ### Calendar schedules Calendar schedules handle exceptions and one-time events that override the regular weekly pattern. **Use cases**: * **Holidays**: Building closes on December 25 — all systems switch to holiday mode * **Maintenance windows**: HVAC zone 3 shuts down Saturday 2–4 PM for filter replacement * **Temporary overrides**: Conference room stays at 20°C for a special event on March 15 Calendar schedules use: * Specific dates (for example, December 25, 2026) * Date ranges (for example, December 23–27, 2026) * Week and day patterns (for example, every third Monday) ## Schedule values Each schedule entry can hold a value of one of these types: | Type | Example | Use case | | - | - | - | | **Number** | `22.0` | Temperature setpoints, fan speeds | | **Boolean** | `true` / `false` | On/off states, enable/disable | | **String** | `"Occupied"` | Named operating modes | | **Enum** | `COMFORT` / `STANDBY` / `OFF` | Predefined mode selections | Schedules can also include **point references**, which link the schedule's values directly to device points. When the schedule activates, the linked point receives the scheduled value. ## Schedule operations ### Discover schedules For integrations that support it, you can discover schedules already configured in the external system. KODE OS queries the controller or system and retrieves available schedules. ### Create schedule Create a new schedule in the external system from KODE OS. Specify the schedule type (weekly or calendar), set values for each time slot, and optionally link it to device points. ### Update schedule Modify an existing schedule's time slots, values, or point references. Changes are pushed to the external system immediately. ### Delete schedule Remove a schedule from the external system. This action cannot be undone. ### Sync schedules Synchronize schedule states between KODE OS and the external system. Sync keeps changes made in either system reflected in the other. ## Schedule workflow ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} flowchart TD A["Discover existing schedules"] --> B["Review discovered schedules"] B --> C{"Need new schedule?"} C -->|Yes| D["Create new schedule"] C -->|No| E["Select existing schedule"] D --> F["Configure time slots and values"] E --> F F --> G["Link to device points"] G --> H["Schedule active in external system"] H --> I["Periodic sync keeps KODE OS updated"] ``` ## Supported integrations Schedule management is available for integrations that expose schedule APIs. Common integrations with full schedule support include: * **Tridium Niagara** — Weekly and calendar schedules with full create, read, update, and delete operations * **Distech BACnet** — Schedule discovery and management via BACnet objects * Other BMS controllers that expose schedule endpoints Check the specific integration page to see if schedule management is supported. The integration's capabilities list Discover Schedules, Create Schedules, and related items when available. ## Troubleshooting > [accordion] Schedule changes are not reflected in the device > > Verify that the schedule is linked to the correct device points. If the schedule has point references, ensure those points exist and are active in the external system. Some controllers also use priority arrays where manual overrides take precedence over scheduled values. > [accordion] Schedule discovery returns no results > > Not all controller configurations expose schedules via their API. Verify that the controller has schedules configured and that the API credentials can read schedule objects. For BACnet systems, ensure the schedule objects are accessible at the configured BACnet device address. > [accordion] Cannot create or update schedules > > Write operations require elevated permissions in the external system. Verify that the connector's credentials have read-write access. Some integrations support schedule discovery (read-only) without supporting schedule creation or modification. # Integrations Catalog Source: https://docs.kodelabs.com/products/integrations/catalog Browse 200+ supported integrations organized by system type > Browse 200+ supported integrations to connect your building systems to KODE OS KODE OS connects to over 200 external systems across building automation, access control, occupancy sensing, metering, and more. Use this catalog to find your integration and get started. ## Access Control Monitor door readers, card access events, and intrusion alerts from physical access control systems. > [card] [Avigilon ACM](/products/integrations/access-control/avigilonACM) > > Collect device status and access events from Avigilon Access Control Manager installations > \ > Discover · Collect > [card] [Avigilon Alta](/products/integrations/access-control/openPath) > > Monitor cloud-managed access control devices and entry events from Avigilon Alta (formerly Openpath) > \ > Discover · Collect > [card] [ICT Protege](/products/integrations/access-control/ictProtege) > > Collect door status and equipment health data from ICT Protege access control systems > \ > Discover · Collect > [card] [Infinias](/products/integrations/access-control/infinias) > > Monitor access control devices and events from Infinias cloud-managed security systems > \ > Discover · Collect > [card] [Integriti](/products/integrations/access-control/integriti) > > Collect access events and schedule data from Inner Range Integriti security systems > \ > Discover · Collect · Schedules > [card] [Kastle](/products/integrations/access-control/kastle) > > Collect card access events and security alarms from Kastle Event Connect > \ > Collect · Historical > [card] [Mirra](/products/integrations/access-control/mirra) > > Manage access cards and receive real-time webhook events from Mirra (CCure) access control > \ > Collect · Webhook > [card] [OnGuard](/products/integrations/access-control/lenel) > > Collect real-time access events via WebSocket from Lenel OnGuard physical access control > \ > Collect · WebSocket > [card] [Open Options Flex](/products/integrations/access-control/openOptions) > > Monitor access devices and events from DNA Fusion open-platform access control software > \ > Discover · Collect > [card] [Paxton](/products/integrations/access-control/paxton) > > Discover and monitor door controllers and access points from Paxton Net2 systems > \ > Discover > [card] [Schneider Access Expert](/products/integrations/access-control/schneiderAccessXpert) > > Monitor entry and exit events for space utilization insights from Schneider AccessXpert > \ > Discover · Collect > [card] [Software House C-CURE 9000](/products/integrations/access-control/softwareHouse) > > Collect access events and send commands to C-CURE 9000 enterprise security management > \ > Discover · Collect · Actions > [card] [Swift Connect](/products/integrations/access-control/swiftConnect) > > Monitor real-time access credentials and permissions from SwiftConnect mobile access > \ > Discover · Collect > [card] [Zerv](/products/integrations/access-control/zerv) > > Collect device status and access events from Zerv mobile-based smart lock systems > \ > Discover · Collect ## Cameras Collect device status, connectivity health, and video system metadata from camera and VMS platforms. > [card] [Arkiv CCTV](/products/integrations/cameras/arkiv) > > Monitor camera status and analytics from Arkiv unified security and AI-powered video platform > \ > Discover · Collect > [card] [Ava Cameras](/products/integrations/cameras/avaCameras) > > Collect camera device status and connectivity data from AVA Aware video management > \ > Discover · Collect > [card] [Avigilon ACC](/products/integrations/cameras/avigilon) > > Monitor cameras and receive real-time webhook events from Avigilon Control Center > \ > Discover · Collect · Webhook > [card] [Axis CCTV](/products/integrations/cameras/axis) > > Collect camera device status and connectivity information from Axis network cameras > \ > Discover · Collect > [card] [Digital Watchdog](/products/integrations/cameras/digitalWatchdog) > > Monitor camera device health and status from Digital Watchdog surveillance systems > \ > Discover · Collect > [card] [Exacq Vision](/products/integrations/cameras/exacqVision) > > Collect camera status and security event data from ExacqVision video management > \ > Discover · Collect > [card] [Genetec Security Center](/products/integrations/cameras/genetec) > > Monitor cameras and security devices from Genetec unified security platform > \ > Discover · Collect > [card] [ITS Cloud Camera](/products/integrations/occupancy/itsCloudCamera) > > Collect object types and geospatial tracking data from Bosch ITS cloud cameras > \ > Discover · Collect > [card] [Milestone](/products/integrations/cameras/milestone) > > Monitor camera health and collect video system data from Milestone XProtect VMS > \ > Discover · Collect > [card] [Salient](/products/integrations/cameras/salient) > > Discover cameras and devices from Salient open-architecture video management platform > \ > Discover ## Controllers Connect to building management systems and automation controllers for HVAC, lighting, and equipment monitoring. > [card] [Daikin](/products/integrations/controllers/daikin) > > Monitor and collect data from Daikin air conditioning and HVAC control systems > \ > Discover · Collect > [card] [Desigo CC](/products/integrations/controllers/desigo) > > Collect data and send commands to Siemens Desigo CC building management systems > \ > Discover · Collect · Actions > [card] [Distech Controls](/products/integrations/controllers/distechBacnet) > > Collect BACnet data and manage schedules from Distech Controls building automation > \ > Discover · Collect · Schedules > [card] [EnOcean](/products/integrations/controllers/enOcean) > > Collect sensor data from EnOcean energy harvesting wireless devices and IoT sensors > \ > Discover · Collect > [card] [enteliWEB](/products/integrations/controllers/enteliWeb) > > Monitor energy usage and equipment data from Delta Controls enteliWEB systems > \ > Discover · Collect > [card] [Hubitat](/products/integrations/controllers/mackinac) > > Collect device and sensor data from Hubitat smart home automation controllers > \ > Discover · Collect > [card] [iScope](/products/integrations/controllers/iScope) > > Synchronize data between iScope building controllers and KODE OS > \ > Discover · Collect > [card] [Johnson Controls Metasys](/products/integrations/controllers/jciMetasys) > > Collect equipment, points, trends, alarms, and audits from Metasys REST API v6 > \ > Discover · Collect · Actions > [card] [Laguna](/products/integrations/controllers/laguna) > > Monitor smart equipment and building systems from Operational Intelligence Laguna platform > \ > Discover · Collect > [card] [MDAS](/products/integrations/controllers/mdas) > > Collect data from MDAS building automation controllers and edge devices > \ > Discover · Collect > [card] [Novant](/products/integrations/controllers/novant) > > Monitor and collect data from Novant smart building management platform > \ > Discover · Collect > [card] [OSIsoft PI](/products/integrations/controllers/osiPi) > > Collect operational data from AVEVA (OSIsoft) PI System historian and data infrastructure > \ > Discover · Collect > [card] [Schneider Smart Connector](/products/integrations/controllers/schneiderElectric) > > Monitor EcoStruxure IoT devices and receive webhook events from Schneider Electric systems > \ > Discover · Collect · Webhook > [card] [Tridium Niagara](/products/integrations/controllers/niagara) > > Collect data, send commands, and manage schedules from Tridium Niagara building automation > \ > Discover · Collect · Actions · Schedules > [card] [Willow](/products/integrations/controllers/willow) > > Collect equipment readings from Willow digital twin platform for base building BMS data > \ > Discover · Collect ## Elevators Monitor elevator status, maintenance events, and emergency diagnostics from elevator management systems. > [card] [Bosch Orion](/products/integrations/elevators/bosch) > > Monitor elevator status and emergency support data from Bosch Orion lift monitoring > \ > Discover · Collect > [card] [KONE](/products/integrations/elevators/kone) > > Receive real-time elevator status and event data via webhooks from KONE connected services > \ > Collect · Webhook > [card] [SafeLine](/products/integrations/elevators/safeline) > > Collect diagnostics and receive real-time alerts from SafeLine Orion cloud lift monitoring > \ > Collect · Webhook > [card] [TKE Elevator](/products/integrations/elevators/tke) > > Monitor elevator equipment and service records through TK Elevator API 3.0 > \ > Discover · Collect · Work Orders ## EV Charging Track charging sessions, station availability, and energy usage from electric vehicle charging networks. > [card] [Blink](/products/integrations/ev-charging/blink) > > Collect charging session data and station status from Blink EV charging stations > \ > Discover · Collect > [card] [ChargePoint](/products/integrations/ev-charging/chargePoint) > > Monitor station availability and charging data from ChargePoint EV charging networks > \ > Discover · Collect > [card] [Flash Parking EV](/products/integrations/ev-charging/flashParkingEVCharging) > > Collect EV charging data from Flash Parking integrated charging infrastructure > \ > Collect > [card] [Monta](/products/integrations/ev-charging/monta) > > Monitor charge points and receive real-time webhook events from Monta EV management > \ > Discover · Collect · Webhook > [card] [Unico](/products/integrations/ev-charging/unico) > > Collect real-time charging session insights and station data from Unico EV systems > \ > Discover · Collect > [card] [Zaptec](/products/integrations/ev-charging/zaptec) > > Monitor charger status and collect session data from Zaptec EV charging solutions > \ > Discover · Collect ## Indoor Air Quality Collect environmental sensor data including temperature, humidity, CO2, VOCs, and particulate matter. > [card] [Airthings](/products/integrations/indoor-air-quality/airthings) > > Monitor indoor air quality metrics and receive webhook alerts from Airthings sensors > \ > Discover · Collect · Webhook > [card] [Atlasen](/products/integrations/indoor-air-quality/atlasen) > > Collect real-time IEQ monitoring data including air, thermal, and acoustic measurements > \ > Discover · Collect > [card] [Attune](/products/integrations/indoor-air-quality/attune) > > Monitor IoT environmental data and receive real-time webhook alerts from Attune sensors > \ > Discover · Collect · Webhook > [card] [Awair](/products/integrations/indoor-air-quality/awair) > > Collect indoor air quality data for health and safety monitoring from Awair sensors > \ > Discover · Collect > [card] [Cloudpop](/products/integrations/indoor-air-quality/cloudpop) > > Collect environmental sensor data streams from Cloudpop IoT management platform > \ > Discover · Collect > [card] [Envelo](/products/integrations/indoor-air-quality/envelo) > > Collect occupancy and air quality data and receive webhook events from Envelo smart sensors > \ > Discover · Collect · Webhook > [card] [Helvar](/products/integrations/indoor-air-quality/helvar) > > Collect lighting, occupancy, daylight, and air quality sensor data from Helvar systems > \ > Discover · Collect > [card] [Kaiterra](/products/integrations/indoor-air-quality/kaiterra) > > Monitor air quality for healthy building operations from Kaiterra Sensedge sensors > \ > Discover · Collect > [card] [Milesight](/products/integrations/indoor-air-quality/milesight) > > Collect multi-sensor environmental data from Milesight cloud-connected IoT devices > \ > Discover · Collect > [card] [Milesight Local](/products/integrations/indoor-air-quality/milesightLocal) > > Collect sensor data directly from Milesight devices on your local network > \ > Discover · Collect > [card] [Platformatics](/products/integrations/indoor-air-quality/platformatics) > > Collect and store environmental data from complex building systems via Platformatics > \ > Discover · Collect > [card] [uHoo](/products/integrations/indoor-air-quality/uHoo) > > Monitor nine air quality factors including CO2, VOCs, and particulate matter from uHoo sensors > \ > Discover · Collect > [card] [WellStat IAQ](/products/integrations/indoor-air-quality/wellstat) > > Monitor indoor air quality and healthy environment metrics from WellStat building sensors > \ > Discover · Collect ## Leak Detection Monitor water flow, detect leaks, and receive real-time alerts from water management and leak-monitoring systems. > [card] [Connected Sensors](/products/integrations/leak-detection/connectedSensors) > > Monitor water usage and detect leaks from Connected Sensors water management systems > \ > Discover · Collect > [card] [Eddy](/products/integrations/leak-detection/eddy) > > Collect real-time water consumption and leak data from Eddy smart water sensors > \ > Discover · Collect > [card] [SMT](/products/integrations/leak-detection/smt) > > Monitor roof leak status from SMT permanently installed sensor systems > \ > Discover · Collect > [card] [Triple Plus](/products/integrations/leak-detection/triplePlus) > > Collect water leak prevention data from Triple Plus systems for small to large buildings > \ > Discover · Collect > [card] [WINT](/products/integrations/leak-detection/wint) > > Monitor AI-powered water leaks and automatic shutoff from WINT systems > \ > Discover · Collect ## Lighting Monitor and control lighting systems including dimming levels, schedules, occupancy-driven lighting, and energy usage. > [card] [Bryte Light](/products/integrations/lighting/bryteLight) > > Collect data from Bryte Light network-powered integrated lighting systems > \ > Discover · Collect > [card] [Ecco Sensors](/products/integrations/lighting/eccoSensors) > > Collect real-time environmental and energy data from Ecco Sensors IoT devices > \ > Discover · Collect > [card] [Enlighted](/products/integrations/lighting/enlighted) > > Collect energy reporting and lighting control data from Enlighted smart sensor systems > \ > Discover · Collect > [card] [Encelium](/products/integrations/lighting/encelium) > > Collect lighting data, manage schedules, and receive WebSocket events from Legrand Encelium > \ > Discover · Collect · Schedules · WebSocket > [card] [Lighting Control (LCL)](/products/integrations/lighting/lightingControl) > > Collect data and manage schedules from LCL intelligent lighting control systems > \ > Discover · Collect · Schedules > [card] [Lutron Athena](/products/integrations/lighting/lutronAthena) > > Collect dynamic lighting control data from Lutron Athena advanced lighting systems > \ > Discover · Collect > [card] [Lutron Quantum](/products/integrations/lighting/lutron) > > Monitor and collect data from Lutron Quantum total light management systems > \ > Discover · Collect > [card] [Lutron Vive](/products/integrations/lighting/lutronVive) > > Collect wireless lighting control data from Lutron Vive systems across spaces and campuses > \ > Discover · Collect > [card] [nLight](/products/integrations/lighting/nLight) > > Collect data from Acuity Brands nLight wired and wireless lighting control systems > \ > Discover · Collect > [card] [Pharos](/products/integrations/lighting/pharos) > > Monitor dynamic lighting installations and control data from Pharos lighting systems > \ > Discover · Collect > [card] [Prolojik](/products/integrations/lighting/prolojik) > > Collect lighting and energy data from Prolojik responsive building environments > \ > Collect > [card] [Smart Core](/products/integrations/lighting/smartCore) > > Collect lighting control and lux level data from SmartCore shared-space systems > \ > Discover · Collect > [card] [Trellix](/products/integrations/lighting/trellix) > > Monitor and collect data from Trellix web-based lighting management platform > \ > Discover · Collect > [card] [WattStopper](/products/integrations/lighting/wattStopper) > > Collect data and manage schedules from WattStopper lighting control devices > \ > Discover · Collect · Schedules > [card] [ZenControl](/products/integrations/lighting/zencontrol) > > Collect lighting status and live dim, scene, colour, and override events from ZenControl > \ > Discover · Collect · WebSocket ## Meters Collect energy consumption, utility usage, and submetering data from metering platforms and energy management systems. > [card] [Accuenergy](/products/integrations/meters/accuenergy) > > Collect real-time energy measurement data from Accuenergy power monitoring devices > \ > Discover · Collect > [card] [APEX](/products/integrations/meters/apex) > > Collect multi-protocol edge device data and receive webhook events from APEX meters > \ > Discover · Collect · Webhook > [card] [Carma](/products/integrations/meters/carma) > > Collect submetering data from CARMA residential and commercial utility metering solutions > \ > Discover · Collect > [card] [Datto](/products/integrations/meters/datto) > > Monitor networking device performance including switches and access points from Datto > \ > Discover · Collect > [card] [Elvaco](/products/integrations/meters/elvaco) > > Collect utility metering data from Elvaco industrial and commercial metering products > \ > Discover · Collect > [card] [Enertiv](/products/integrations/meters/enertiv) > > Collect energy management and submetering data from Enertiv building analytics > \ > Discover · Collect > [card] [Fludia](/products/integrations/meters/fludia) > > Monitor energy and multi-fluid consumption data from Fludia metering solutions > \ > Discover · Collect > [card] [Gema](/products/integrations/meters/gema) > > Collect energy management data from GemaLogic (SolveraLynx) metering platform > \ > Discover · Collect > [card] [Greenworld Solutions](/products/integrations/meters/greenworldSolutions) > > Monitor and optimize energy consumption from Greenworld Solutions measurement systems > \ > Discover · Collect > [card] [Inverter](/products/integrations/meters/inverter) > > Collect solar inverter data and receive webhook events for energy reporting and analysis > \ > Discover · Collect · Webhook > [card] [Kocos](/products/integrations/meters/kocos) > > Collect test and measurement data and receive webhook events from KoCoS energy systems > \ > Discover · Collect · Webhook > [card] [IES MACH](/products/integrations/meters/mach) > > Monitor building energy footprint and asset performance from IES MACH analytics > \ > Discover · Collect > [card] [MeterConnex](/products/integrations/meters/meterConnex) > > Collect automated daily meter data and receive webhook events from MeterConnex systems > \ > Discover · Collect · Webhook > [card] [NuEnergen](/products/integrations/meters/nuEnergen) > > Collect energy utilization data and efficiency recommendations from NuEnerGen analysis > \ > Discover · Collect > [card] [O3 HUB](/products/integrations/meters/waterloo) > > Collect multi-utility metering data and receive webhook events from O3 HUB platform > \ > Discover · Collect · Webhook > [card] [Pagi](/products/integrations/meters/pagi) > > Collect real-time and historical metering data from PAGI-e Canadian utility metering > \ > Discover · Collect > [card] [PME](/products/integrations/meters/pme) > > Collect power monitoring data from Schneider Electric Power Monitoring Expert systems > \ > Collect > [card] [Redaptive](/products/integrations/meters/redaptive) > > Collect circuit-level energy data from Redaptive Power Meter installations > \ > Discover · Collect > [card] [Sapient](/products/integrations/meters/sapient) > > Collect real-time and historical electricity usage data from Sapient energy analytics > \ > Discover · Collect > [card] [SHM Aphex](/products/integrations/meters/shmAphex) > > Collect meter data from SHM Aphex Meter Online monitoring platform > \ > Discover · Collect > [card] [SkySpark](/products/integrations/meters/skySpark) > > Collect energy management and NABERS performance data from SkySpark analytics > \ > Discover · Collect > [card] [Smart Meter Texas](/products/integrations/meters/smartMeterTexas) > > Collect 15-minute electric interval reads and meter details from Smart Meter Texas > \ > Discover · Collect > [card] [Utilivisor](/products/integrations/meters/utilivisor) > > Collect utility submetering and monitoring data from Utilivisor commercial building systems > \ > Discover · Collect > [card] [Veolia](/products/integrations/meters/veolia) > > Collect electric meter status, cumulative energy, and demand from EMSYS or HUBGRADE > \ > Discover · Collect · Historical > [card] [Verdigris](/products/integrations/meters/verdigris) > > Collect real-time and historical electrical energy data from Verdigris monitoring systems > \ > Discover · Collect > [card] [Walchem Fluent](/products/integrations/meters/fluent) > > Collect water treatment management data from Walchem Fluent cloud-based analytics > \ > Discover · Collect > [card] [Wattics](/products/integrations/meters/wattics) > > Collect energy consumption data and receive webhook events from Wattics energy management > \ > Discover · Collect · Webhook > [card] [Wyse Meter](/products/integrations/meters/wyseMeter) > > Discover and monitor utility metering devices from Wyse Meter energy management systems > \ > Discover ## Occupancy Track real-time and historical people counts, desk utilization, and space usage from occupancy sensing platforms. > [card] [A1 Innovation Group](/products/integrations/occupancy/a1IG) > > Collect real-time occupancy data for areas and zones from A1 Innovation Group sensors > \ > Discover · Collect > [card] [Abakus](/products/integrations/occupancy/abakus) > > Collect people counting data for space utilization insights from Abakus Analytics sensors > \ > Discover · Collect > [card] [Avuity](/products/integrations/occupancy/avuity) > > Measure and analyze how people interact with space from AVUITY occupancy sensing > \ > Discover · Collect > [card] [Butlr](/products/integrations/occupancy/butlr) > > Collect sensor data and receive webhook events from Butlr thermal occupancy sensors > \ > Discover · Collect · Webhook > [card] [Density](/products/integrations/occupancy/density) > > Collect real-time and historical people counting data from Density occupancy sensors > \ > Discover · Collect > [card] [Enlighted People Counting](/products/integrations/occupancy/enlightedPeopleCounting) > > Collect people counting data from Irisys Vector 4D sensors on the Enlighted network > \ > Discover · Collect > [card] [Extron](/products/integrations/occupancy/extron) > > Collect AV device mode and occupancy data from Extron room and space systems > \ > Discover · Collect > [card] [Freespace](/products/integrations/occupancy/freeSpace) > > Collect space utilization and occupancy data from Freespace sensor systems > \ > Discover · Collect > [card] [Freespace Utilization V2](/products/integrations/occupancy/freeSpaceUtilization) > > Collect enhanced space utilization insights from Freespace Utilization API version 2 > \ > Discover · Collect > [card] [Framery](/products/integrations/occupancy/framery) > > Monitor smart pod occupancy, connection status, and usage sessions > \ > Discover · Collect · Historical > [card] [Fyma](/products/integrations/occupancy/fyma) > > Collect commercial real estate and retail portfolio utilization data from Fyma analytics > \ > Discover · Collect > [card] [Hella Aglaia](/products/integrations/occupancy/hellaAglaia) > > Collect occupancy and people counting data from HELLA Aglaia sensor solutions > \ > Discover · Collect > [card] [Impark](/products/integrations/occupancy/impark) > > Collect parking occupancy and utilization data from Impark management systems > \ > Discover · Collect > [card] [Kontakt](/products/integrations/occupancy/kontakt) > > Collect indoor location and occupancy data from Kontakt.io BLE beacon systems > \ > Discover · Collect > [card] [Lambent Spaces](/products/integrations/occupancy/lambent) > > Collect Wi-Fi-derived occupancy, utilization, and capacity by floor and zone > \ > Discover · Collect · Historical > [card] [Nimway](/products/integrations/occupancy/nimway) > > Collect smart office occupancy data and receive webhook events from Nimway workplace sensors > \ > Discover · Collect · Webhook > [card] [Point Grab](/products/integrations/occupancy/pointGrab) > > Collect space utilization data and receive webhook events from PointGrab ceiling sensors > \ > Discover · Collect · Webhook > [card] [Sembient](/products/integrations/occupancy/sembient) > > Collect detailed occupancy data and receive webhook events from Sembient building sensors > \ > Discover · Collect · Webhook > [card] [Sighthound](/products/integrations/occupancy/sighthound) > > Collect vehicle and people data and receive webhook events from Sighthound cameras > \ > Discover · Collect · Webhook > [card] [Trax](/products/integrations/occupancy/trax) > > Collect custodial operations and space utilization data from Trax Analytics platform > \ > Discover · Collect > [card] [VergeSense](/products/integrations/occupancy/vergeSense) > > Collect workplace analytics and receive webhook events from VergeSense occupancy sensors > \ > Discover · Collect · Webhook > [card] [Webex](/products/integrations/occupancy/webex) > > Collect room device data and receive webhook events from Cisco Webex collaboration systems > \ > Discover · Collect · Webhook > [card] [WiFi Occupancy (IMF)](/products/integrations/occupancy/wifi) > > Collect real-time occupancy data by counting connected devices across WiFi networks > \ > Discover · Collect > [card] [Xandar](/products/integrations/occupancy/xandar) > > Collect radar-based occupancy data and receive webhook events from Xandar Kardian sensors > \ > Discover · Collect · Webhook > [card] [XY Sense](/products/integrations/occupancy/xySense) > > Collect real-time occupancy tracking data and receive webhook events from XY Sense sensors > \ > Discover · Collect · Webhook ## Parking Monitor parking space availability, utilization rates, and ticketing data from parking management systems. > [card] [Flash Parking](/products/integrations/parking/flashParking) > > Collect parking ticket data and receive real-time webhook events from Flash Parking > \ > Discover · Collect · Webhook > [card] [JustPark](/products/integrations/parking/justPark) > > Collect parking lot availability and utilization data from JustPark booking platform > \ > Discover · Collect > [card] [Park Assist](/products/integrations/parking/parkAssist) > > Collect parking guidance and space availability data from Park Assist sensor systems > \ > Discover · Collect > [card] [ParkChamp](/products/integrations/parking/parkChamp) > > Collect parking revenue and utilization data from ParkChamp management systems > \ > Collect > [card] [ParkHelp](/products/integrations/parking/parkHelp) > > Monitor parking space status and utilization from ParkHelp guidance systems > \ > Discover · Collect > [card] [Parking Detection](/products/integrations/parking/parkingDetection) > > Monitor real-time parking lot occupancy from ParkingDetection sensor systems > \ > Discover · Collect > [card] [Precise ParkLink](/products/integrations/parking/precisePark) > > Collect parking revenue and utilization data from Precise ParkLink control systems > \ > Discover · Collect > [card] [Quercus](/products/integrations/parking/quercus) > > Collect parking occupancy and vehicle data from Quercus Technologies systems > \ > Discover · Collect > [card] [WOHR](/products/integrations/parking/wohr) > > Collect automated parking system status and utilization data from WOHR installations > \ > Collect ## Reservations Collect room booking, visitor management, and event scheduling data from reservation and workspace platforms. > [card] [Accruent EMS](/products/integrations/reservations/ems) > > Collect workspace and event scheduling data from Accruent EMS reservation software > \ > Discover · Collect > [card] [CloudGate](/products/integrations/reservations/cloudGate) > > Collect visitor identity data, manage access, and receive webhook events from CloudGate VIAM > \ > Collect · Actions · Webhook > [card] [Condeco](/products/integrations/reservations/condeco) > > Collect room and workspace utilization data and receive webhook events from Condeco > \ > Discover · Collect · Webhook > [card] [Momentus](/products/integrations/reservations/momentus) > > Collect venue and event management data from Momentus Technologies scheduling platform > \ > Collect > [card] [Outlook](/products/integrations/reservations/outlook) > > Collect room booking data and manage calendar events through Microsoft Outlook integration > \ > Discover · Collect · Actions > [card] [Parkonect](/products/integrations/reservations/parkonect) > > Collect parking reservation data, manage bookings, and receive webhook events from Parkonect > \ > Collect · Actions · Webhook > [card] [TDS Visitor Management](/products/integrations/reservations/tds) > > Collect visitor check-in and management data from TDS visitor management systems > \ > Collect > [card] [TRIRIGA](/products/integrations/reservations/tririgaFDH) > > Collect real estate and facilities management data from IBM TRIRIGA platform > \ > Collect ## Work Orders Collect, create, and track maintenance work orders, inspection records, and service requests from CMMS and facility management platforms. > [card] [Angus](/products/integrations/work-orders/angus) > > Collect work order data and create maintenance requests in Angus MRI facility management > \ > Discover · Collect · Actions > [card] [AssetOps](/products/integrations/work-orders/assetOps) > > Collect and create work orders in KODE OS AssetOps digital maintenance module > \ > Collect · Actions > [card] [BuiltSpace](/products/integrations/work-orders/builtspace) > > Collect digital twin and maintenance data from BuiltSpace facility management > \ > Collect > [card] [CF Connect](/products/integrations/work-orders/cfConnect) > > Collect work order data and create requests through CF Connect Salesforce integration > \ > Collect · Actions > [card] [CFS GS](/products/integrations/work-orders/cfsGS) > > Collect IoT-driven work order data and automate service workflows through CFS GS > \ > Discover · Collect · Actions > [card] [Corrigo](/products/integrations/work-orders/corrigo) > > Collect and create work orders in Corrigo cloud-based facilities management platform > \ > Discover · Collect · Actions > [card] [Cove](/products/integrations/work-orders/cove) > > Collect and create work orders through Cove GraphQL-based work order management > \ > Collect · Actions > [card] [Gridium](/products/integrations/work-orders/gridium) > > Collect building operations data and receive webhook events from Gridium platform > \ > Collect · Webhook > [card] [Impak](/products/integrations/work-orders/impak) > > Collect and create work orders through Impak maintenance management system > \ > Collect · Actions > [card] [Manager Plus](/products/integrations/work-orders/managerPlus) > > Collect and create work orders through Eptura ManagerPlus maintenance management > \ > Discover · Collect · Actions > [card] [MaintainX](/products/integrations/work-orders/maintainX) > > Collect assets, current meter readings, and work orders from MaintainX > \ > Discover · Collect > [card] [IBM Maximo (CF)](/products/integrations/work-orders/maximoCF) > > Collect and create work orders in IBM Maximo enterprise asset management > \ > Discover · Collect · Actions > [card] [IBM Maximo (FDH)](/products/integrations/work-orders/maximoFDH) > > Collect asset and maintenance data from IBM Maximo for predictive maintenance workflows > \ > Collect > [card] [NCMMS](/products/integrations/work-orders/ncmms) > > Collect and create work orders in the National Computerized Maintenance Management System > \ > Collect · Actions > [card] [Nuvolo](/products/integrations/work-orders/nuvolo) > > Collect and create work orders in Nuvolo connected workplace management platform > \ > Collect · Actions > [card] [Open FASAP](/products/integrations/work-orders/openfasap) > > Collect and create tickets through Open FASAP API-based service management > \ > Collect · Actions > [card] [Prism](/products/integrations/work-orders/prism) > > Collect and create work orders in Prism by Building Engines maintenance platform > \ > Collect · Actions > [card] [QR Connect](/products/integrations/work-orders/qrConnect) > > Collect event-triggered work orders and receive webhook events from QR Connect > \ > Collect · Actions · Webhook > [card] [Service Channel](/products/integrations/work-orders/serviceChannel) > > Collect and create work orders in ServiceChannel facilities management platform > \ > Discover · Collect · Actions > [card] [Service Channel (Lowes)](/products/integrations/work-orders/serviceChannelLowes) > > Collect and create work orders through the ServiceChannel Lowes-specific integration > \ > Discover · Collect · Actions > [card] [ServiceNow](/products/integrations/work-orders/serviceNow) > > Collect work orders, create tickets, and receive webhook events from ServiceNow ITSM > \ > Collect · Actions · Webhook > [card] [Vantify](/products/integrations/work-orders/vantify) > > Collect work orders, create requests, and receive webhook events from Vantify CAFM > \ > Collect · Actions · Webhook > [card] [Visitt](/products/integrations/work-orders/visitt) > > Collect and create work orders through Visitt property management partner API > \ > Collect · Actions ## Smart Bathroom Monitor dispenser levels, fixture status, and cleaning metrics from smart restroom management systems. > [card] [KOLO](/products/integrations/smart-bathroom/kolo) > > Monitor dispenser stock levels and fixture status from KOLO smart restroom systems > \ > Discover · Collect > [card] [Mero](/products/integrations/smart-bathroom/mero) > > Collect consumable levels and cleaning data from Mero peel-and-stick restroom sensors > \ > Discover · Collect > [card] [Tork](/products/integrations/smart-bathroom/tork) > > Collect hygiene and cleaning data and receive webhook events from Tork smart restroom systems > \ > Discover · Collect · Webhook ## Smart Lockers Monitor locker availability, usage patterns, and access events from smart locker management systems. > [card] [Parcel Pending](/products/integrations/smart-lockers/parcelPending) > > Collect locker usage and parcel delivery data from Parcel Pending smart locker systems > \ > Discover · Collect > [card] [Vecos](/products/integrations/smart-lockers/vecos) > > Collect keyless locker usage and management data from Vecos smart locker systems > \ > Discover · Collect > [card] [Yale Accentra](/products/integrations/smart-lockers/yale) > > Collect smart door lock status and performance data from Yale Accentra systems > \ > Collect ## Smart Shades Control and monitor motorized window shades for daylight harvesting and occupant comfort. > [card] [RYSE](/products/integrations/smart-shades/ryse) > > Collect shade position and control data from RYSE SmartShade motorized window systems > \ > Discover · Collect ## Outdoor Air Quality Collect external air quality measurements including pollutant levels and environmental conditions. > [card] [Aeroqual](/products/integrations/outdoor-air-quality/specto) > > Collect air quality monitoring data and device status from Aeroqual outdoor sensors > \ > Discover · Collect > [card] [Bosch AQI](/products/integrations/outdoor-air-quality/boschAQI) > > Collect outdoor air quality data from Bosch Immission Measurement Box (IMB) sensors > \ > Discover · Collect ## Utility Power Monitor power supply status, outlet control, and grid connectivity from utility power management systems. > [card] [Eevion Hypercharge](/products/integrations/utility-power/hypercharge) > > Collect integrated EV charging data from Eevion Hypercharge power management systems > \ > Discover · Collect > [card] [iSocket](/products/integrations/utility-power/iSocket) > > Monitor and control remote power outlets and receive webhook events from iSocket devices > \ > Discover · Collect · Webhook > [card] [Muse (Envizi)](/products/integrations/utility-power/muse) > > Collect monthly performance reports and sustainability metrics from IBM Envizi platform > \ > Collect ## Weather Collect local weather station data for energy optimization and building performance analysis. > [card] [Tempest](/products/integrations/weather/tempest) > > Collect local weather data for energy management optimization from WeatherFlow Tempest > \ > Discover · Collect ## Waste Metering Track waste container fill levels and collection schedules from smart waste management systems. > [card] [Carrot](/products/integrations/waste-metering/carrot) > > Collect waste management and sustainability optimization data from Carrot platform > \ > Discover · Collect > [card] [Compology](/products/integrations/waste-metering/compology) > > Monitor waste container levels and collection efficiency from Compology smart cameras > \ > Discover · Collect ## Wireless Sensors Collect data from wireless sensor networks for predictive maintenance, environmental monitoring, and asset tracking. > [card] [iCare](/products/integrations/wireless-sensors/iCare) > > Collect predictive maintenance data and receive webhook events from iCare AI-powered sensors > \ > Discover · Collect · Webhook > [card] [iMonnit](/products/integrations/wireless-sensors/imonnit) > > Collect air humidity and temperature data and receive webhook events from iMonnit sensors > \ > Discover · Collect · Webhook ## Notifications Send alerts and notifications to external communication and resident management platforms. > [card] [Venn City](/products/integrations/notifications/vennCity) > > Send automated notifications and alerts to residents through VennCity lifecycle management > \ > Actions ## Asset Management Discover and catalog physical and virtual assets for inventory tracking and security visibility. > [card] [Armis](/products/integrations/asset-management/armis) > > Discover and catalog managed and unmanaged assets from Armis security visibility platform > \ > Discover ## Project Management Collect project data, documents, and milestones from construction and capital project management platforms. > [card] [Kahua](/products/integrations/project-management/kahua) > > Collect project management data from Kahua cloud-based construction platform > \ > Collect ## Other Additional integrations for smart home devices, MQTT-based IoT, emergency lighting, and specialized building systems. > [card] [Bosch Home Connect](/products/integrations/other/boschHomeConnect) > > Monitor and control Bosch smart home appliances through Home Connect API > \ > Discover · Collect > [card] [Cisco RoomOS](/products/integrations/other/ciscoRoomOS) > > Collect collaboration and AV device data from Cisco RoomOS meeting room systems > \ > Discover · Collect > [card] [Disruptive Technologies](/products/integrations/other/disruptiveTechnologies) > > Collect wireless sensor data and receive webhook events from Disruptive Technologies IoT > \ > Discover · Collect · Webhook > [card] [Ecobee](/products/integrations/other/ecobee) > > Collect thermostat data and manage schedules from Ecobee SmartBuildings platform > \ > Discover · Collect · Schedules > [card] [Enersponse](/products/integrations/other/enersponse) > > Collect energy optimization and demand response data from Enersponse platform > \ > Collect > [card] [JLL OneView](/products/integrations/other/jllOneview) > > Collect real-time facility data from JLL OneView enterprise real estate platform > \ > Collect > [card] [KODE MQTT](/products/integrations/other/kodeMqtt) > > Connect IoT devices using MQTT protocol for real-time publish/subscribe data communication > \ > Discover · Collect · Actions · Schedules > [card] [Logic One](/products/integrations/other/logicOne) > > Collect BACnet data and manage schedules through Logic One network communication API > \ > Discover · Collect · Schedules > [card] [Nalco](/products/integrations/other/nalcoapi) > > Collect water treatment configuration and operational data from Nalco systems > \ > Discover · Collect > [card] [Q-SYS Reflect](/products/integrations/other/qSys) > > Monitor AV device status and health from Q-SYS Reflect Enterprise Manager > \ > Discover · Collect > [card] [ZoneWorks (ELS)](/products/integrations/other/zoneWorks) > > Monitor emergency lighting system status and alerts from Clevertronics ZoneWorks > \ > Discover · Collect # Daikin Source: https://docs.kodelabs.com/products/integrations/controllers/daikin Connect Daikin to KODE OS for controller data > Connect Daikin to KODE OS for controller data integration ## Overview Use this integration to connect Daikin HVAC controllers to KODE OS. You can discover units and points, then monitor temperatures, operating modes, status, and energy-related readings for operations and optimization. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Daikin and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Daikin developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Daikin developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Daikin** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **URL** | Yes | text | The base URL or IP address of the external system | | **Tenant ID** | Yes | password | The tenant identifier in the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Application ID** | Yes | password | The application ID from the vendor's developer portal | | **Subscription Key** | Yes | password | The subscription key for the vendor's API | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Daikin system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Daikin developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Daikin system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Daikin API. # Desigo CC Source: https://docs.kodelabs.com/products/integrations/controllers/desigo Connect Desigo CC to KODE OS for controller data > Connect Desigo CC to KODE OS for controller data integration ## Overview Use this integration to connect Siemens Desigo CC to KODE OS. You can discover devices and points, collect fire and building data with hybrid pull-and-push delivery, and run supported actions from KODE OS when your deployment allows. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Desigo CC](https://kodelabs.com/integration/desigo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Desigo CC and access to their API or developer portal * Username and password credentials for the Desigo CC system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Desigo CC** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Client Version** | Yes | dropdown | The version of the vendor's API client | | **Auth Type** | Yes | dropdown | The authentication method to use | | **Type IDs** | Conditional | text | Configuration field for Type IDs | | **Discipline IDs** | Conditional | text | Configuration field for Discipline IDs | | **External URL** | No | text | An additional external URL for the integration | | **Local IP** | No | password | The local network IP address of the on-site system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Desigo CC system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Desigo CC, KODE OS maps them to the following device types and data points: ### Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Quiet` | **Quiet** -- no alarm condition / **Fault** -- system fault detected / **Active** -- alarm is currently active | -- | No | `fire_alarm` | Polling | ## What Data You Get ### Point History Time-series readings including Quiet, collected at regular intervals from connected devices ### BMS Events Desigo building management system events including controller alerts and system notifications ### Polling Schedule * **Point History** -- Default polling: 3 minutes (min: 3 minutes, max: 1 hours) * **DesigoEvents** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions This integration supports actions that allow you to send commands to the Desigo CC system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Desigo CC system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Desigo CC system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Desigo CC API. # Distech Controls Source: https://docs.kodelabs.com/products/integrations/controllers/distechBacnet Connect Distech Controls to KODE OS for controller data > Connect Distech Controls to KODE OS for controller data integration ## Overview Use this integration to connect Distech Controls building systems to KODE OS. You can discover devices and points, collect sensor data, and work with schedules when your site exposes schedule discovery. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Schedules** | Supported | See [Distech Controls](https://kodelabs.com/integration/distech-controls/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Discover Schedules * Update Schedules ## Prerequisites * An active account with Distech Controls and access to their API or developer portal * Username and password credentials for the Distech Controls system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Distech Controls** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Protocol** | Yes | dropdown | The communication protocol to use | | **Version** | Yes | dropdown | The API or firmware version to use | | **Range Low Limit** | No | text | Configuration field for Range Low Limit | | **Range High Limit** | No | text | Configuration field for Range High Limit | | **Network Address (separated with comma), default value is 1** | No | text | Configuration field for Network Address (separated with comma), default value is 1 | | **Scan Network** | No | dropdown | Options: `False`, `True` | | **Device ID** | No | text | The device identifier in the external system | | **Local IP** | No | password | The local network IP address of the on-site system | | **Model** | No | dropdown | The hardware or software model of the system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Distech Controls system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 10 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Distech Controls system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Distech Controls system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Distech Controls system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Distech Controls API. # EnOcean Source: https://docs.kodelabs.com/products/integrations/controllers/enOcean Connect EnOcean to KODE OS for controller data > Connect EnOcean to KODE OS for controller data integration ## Overview Use this integration to connect EnOcean SmartServer IoT data to KODE OS over MQTT. You can discover devices and points and collect wireless sensor data for smart-building monitoring. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | MQTT | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [EnOcean](https://kodelabs.com/integration/enocean/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * MQTT Data Collection ## Prerequisites * Access to the MQTT broker used by EnOcean * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **EnOcean** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Collect Mode** | Yes | dropdown | The data collection mode (e.g., SNAPSHOT, DELTA) | | **IP Address** | Conditional | text | The IP address of the on-site controller or device | | **Port** | Conditional | text | The port number for connecting to the system | | **Segment Controller ID** | Conditional | text | The segment controller identifier in the lighting network | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the EnOcean system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from EnOcean, KODE OS maps them to the following device types and data points: ### Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `in` | Input signal value | -- | No | MQTT | | 2 | `locValue` | **True** -- locValue is active / **False** -- locValue is not active | -- | No | MQTT | | 3 | `state` | Current operating state | -- | No | MQTT | | 4 | `health` | Device health status | -- | No | MQTT | | 5 | `connection` | Device connection status | -- | No | MQTT | | 6 | `action` | Last triggered action | -- | No | MQTT | | 7 | `wasProvisioned` | **True** -- wasProvisioned is active / **False** -- wasProvisioned is not active | -- | No | MQTT | ## What Data You Get ### Point History Time-series readings including in, locValue, state, health, connection, action, wasProvisioned, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the EnOcean devices. Ensure the MQTT client has subscribe permissions. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the EnOcean system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the EnOcean API. # Enteli Web Source: https://docs.kodelabs.com/products/integrations/controllers/enteliWeb Connect Enteli Web to KODE OS for controller data > Connect Enteli Web to KODE OS for controller data integration ## Overview Use this integration to connect Delta EnteliWEB to KODE OS. You can discover devices and points, collect sensor and non-sensor data, and ingest historical energy and operational series for analysis and reporting. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Enteli Web](https://kodelabs.com/integration/enteli-web/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Enteli Web and access to their API or developer portal * Username and password credentials for the Enteli Web system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Enteli Web** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **Collect Type** | Yes | dropdown | The data collection method to use | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Enteli Web system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Enteli Web system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Enteli Web system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Enteli Web API. # iScope Source: https://docs.kodelabs.com/products/integrations/controllers/iScope Connect iScope to KODE OS for controller data > Connect iScope to KODE OS for controller data integration ## Overview Use this integration to connect your iScope controller to KODE OS. You can discover devices and points and synchronize sensor readings using historical collection aligned to your iScope deployment. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with iScope and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **iScope** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the iScope system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the iScope platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the iScope system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the iScope API. # Johnson Controls Metasys Source: https://docs.kodelabs.com/products/integrations/controllers/jciMetasys Connect Johnson Controls Metasys to KODE OS for equipment, points, trends, alarms, audits, and commands > Connect Johnson Controls Metasys REST API v6 to KODE OS ## Overview Use this integration to connect Metasys through the Telus SDF gateway. You can discover equipment and points, collect current and historical values, monitor alarms and audits, and run supported point commands. | Property | Value | | - | - | | **System Type** | Controllers | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT and HISTORICAL | | **Actions** | Supported when enabled | ## Supported capabilities * Discover devices and points * Collect current point values * Collect historical point data * Collect alarms and audit logs * Invoke supported point commands ## Prerequisites * Access to Metasys REST API v6 through the Telus SDF gateway * A Telus SDF developer key * Metasys permissions for the required equipment and activities * Monitoring and Commanding licensing when you need point actions * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Johnson Controls Metasys`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **URL** | Yes | text | Telus SDF gateway URL for Metasys | | **API Key** | Yes | password | Telus SDF developer key | | **Notes** | No | text | Additional connection details | KODE OS sends the developer key in the `X-TELUS-SDF-Developer-Key` header. Native Metasys login and refresh-token endpoints are not used. ## Discover devices and points After you save the connector, select `Discover`. KODE OS reads the equipment hierarchy and keeps equipment-class nodes as devices. It then loads each device's points and schema details. Review the returned devices and points, then save the records you want in KODE OS. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What data you get ### Point history The connector batches current-value requests and stores values independently for each point. It also collects historical samples for trended attributes. * **Current values** — Default polling: 10 minutes * **Historical values** — Collected in bounded date windows ### Alarms and audit logs KODE OS collects Metasys activities and separates them by activity type: * `alarm` records become KODE OS alarms * `audit` records become KODE OS audit logs The connector polls activities every five minutes with an overlapping window. Vendor-specific details remain available in custom fields. > [!NOTE] > > Audit activity depends on the logging and permissions configured in your Metasys environment. ## Available actions KODE OS can expose commands reported by Metasys, including: * Adjust * Override and temporary override * Release override and release all * Change default value Command availability depends on Metasys role-based access, Monitoring and Commanding licensing, and gateway support. KODE OS displays a permission error when the current credential cannot invoke a command. For more details, see the [Actions guide](/products/integrations/capabilities/actions). ## Use cases Once connected, you can: * Monitor equipment and point values across a building * Analyze historical trends for performance issues * Review alarms and audit activity in KODE OS * Adjust supported setpoints and overrides remotely ## Troubleshooting > [accordion] Authentication or connection error > > Verify the gateway URL and Telus SDF developer key. Confirm the gateway accepts Metasys REST API v6 requests. > [accordion] Point values return a permission error > > Confirm the Metasys account can read the object. The connector uses batch object requests because direct point-attribute routes may be blocked. > [accordion] Commands are unavailable > > Confirm Metasys role permissions, Monitoring and Commanding licensing, and gateway support for command requests. > [accordion] Audit logs are empty > > Verify that audit logging is enabled and the developer key can access audit activities in the target environment. # Laguna Source: https://docs.kodelabs.com/products/integrations/controllers/laguna Connect Laguna to KODE OS for controller data > Connect Laguna to KODE OS for controller data integration ## Overview Use this integration to connect Laguna controllers to KODE OS. You can discover devices and points and collect real-time sensor data for monitoring and automation workflows. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Laguna](https://kodelabs.com/integration/laguna/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Laguna and access to their API or developer portal * Username and password credentials for the Laguna system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Laguna** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Categories(Comma separated)** | No | text | Configuration field for Categories(Comma separated) | | **Device Names(Comma separated)** | No | text | Configuration field for Device Names(Comma separated) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Laguna system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 10 minutes (min: 10 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Laguna system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Laguna system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Laguna API. # Hubitat Source: https://docs.kodelabs.com/products/integrations/controllers/mackinac Connect Hubitat to KODE OS for controller data > Connect Hubitat to KODE OS for controller data integration ## Overview Use this integration to connect Hubitat to KODE OS. You can discover devices and points and collect sensor data from your Hubitat hub alongside your broader building context. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Hubitat](https://kodelabs.com/integration/abb-integra/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Hubitat and access to their API or developer portal * API key or token from the Hubitat platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Hubitat platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Hubitat** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Token** | Yes | password | The API token for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Hubitat system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Hubitat, KODE OS maps them to the following device types and data points: ### Controller Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Air` | Current air temperature reading (°C) | °C | No | Polling | | 2 | `Glass` | Glass surface temperature reading (°C) | °C | No | Polling | | 3 | `Frame` | Frame surface temperature reading (°C) | °C | No | Polling | | 4 | `Panel` | Panel surface temperature reading (°C) | °C | No | Polling | | 5 | `Pyranometer` | Solar irradiance measurement | solarIrradiance | No | Polling | | 6 | `Solar Cell` | Solar irradiance measurement | solarIrradiance | No | Polling | | 7 | `Glass Flux TC` | Heat flux thermocouple temperature (°C) | °C | No | Polling | | 8 | `Frame Flux TC` | Heat flux thermocouple temperature (°C) | °C | No | Polling | | 9 | `Glass Flux` | Heat flux measurement (W/m²) | heatFlux | No | Polling | | 10 | `Frame Flux` | Heat flux measurement (W/m²) | heatFlux | No | Polling | | 11 | `Wind Speed` | Wind speed (m/s) | windspeed | No | Polling | | 12 | `Mean Radiant Temperature` | Current temperature reading (W/m²) | pyrgeometer | No | Polling | | 13 | `WEMS Film` | WEMS film temperature reading (°C) | °C | No | Polling | | 14 | `Outside Air Temp` | Outside air temperature (°C) | °C | No | Polling | | 15 | `Cloud Coverage` | Cloud coverage (%) | % | No | Polling | | 16 | `Dew Point` | Dew point temperature (°C) | °C | No | Polling | | 17 | `Outside Air Humid` | Outside air relative humidity (%) | % | No | Polling | | 18 | `Precipitation` | Current precipitation type or amount | -- | No | Polling | | 19 | `Outside Air Pressure` | Atmospheric air pressure (mbar) | millibars | No | Polling | | 20 | `Time` | Wind speed measurement (m/s) | metersPerSecond | No | Polling | | 21 | `Wind Angle` | Wind direction angle (°) | degrees | No | Polling | ## What Data You Get ### Point History Time-series readings including Air, Glass, Frame, Panel, Pyranometer, Solar Cell, Glass Flux TC, Frame Flux TC, and 13 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Hubitat platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Hubitat system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Hubitat API. # MDAS Source: https://docs.kodelabs.com/products/integrations/controllers/mdas Connect MDAS to KODE OS for controller data > Connect MDAS to KODE OS for controller data integration ## Overview Use this integration to connect MDAS to KODE OS. You can discover devices and points, collect sensor data through REST, and receive webhook payloads with file validation when your workflow requires it. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with MDAS and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **MDAS** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **Modbus Instance** | Yes | dropdown | The Modbus device instance number | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the MDAS system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from MDAS, KODE OS maps them to the following device types and data points: ### IO Reader / Controller Canonical Type: `IOREADER` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Normal` | **Normal** -- operating within expected parameters / **Alarm** -- abnormal condition detected | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Normal, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the MDAS platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the MDAS system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the MDAS API. # Tridium Niagara Source: https://docs.kodelabs.com/products/integrations/controllers/niagara Connect Tridium Niagara to KODE OS for controller data > Connect Tridium Niagara to KODE OS for controller data integration ## Overview Use this integration to connect your Tridium Niagara building automation system to KODE OS. You can discover BAS devices and points, collect sensor data with delta collection, manage schedules, and run supported actions from a centralized platform. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | DELTA | | **Schedules** | Supported | | **Actions** | Supported | See [Tridium Niagara](https://kodelabs.com/integration/tridium-niagara4/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Discover Schedules * Create Schedules * Update Schedules * Delete Schedules ## Prerequisites * An active account with Tridium Niagara and access to their API or developer portal * Username and password credentials for the Tridium Niagara system * KODE OS environment with access to Data Sources * The KODE OS Niagara driver installed on the station when you use the KODE OS module ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Tridium developer program](https://www.tridium.com/us/en/purchase/developer-program) * [Tridium documents library](https://www.tridium.com/content/tridium/language-masters/en/services-support/library.html) ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Tridium Niagara** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Auth Type** | Yes | dropdown | The authentication method to use | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Conditional | text | The OAuth authorization URL for token exchange | | **Driver Version** | Yes | dropdown | The driver or API version for communication | | **Room** | No | text | The specific room this connector is associated with | | **Model** | Yes | dropdown | The hardware or software model of the system. Options: `Vykon`, `Honeywell`, `FX`, `Distech`, `KMC` | | **Module Version** | No | text | Niagara module version for this connector | | **Niagara Version** | No | text | Niagara runtime version | | **Module Name** | No | text | Niagara module name | | **Folder(Leave it blank to discover all devices)** | No | text | Optional folder path to limit discovery; leave blank to discover all devices | | **devicesRootSlot** | No | text | Niagara slot path that roots device discovery | | **Local IP** | No | password | The local network IP address of the on-site system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Tridium Niagara system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Tridium Niagara data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **name** | `msgText` | -- | | **deviceId** | `sourceSlot` | -- | | **priority** | `derived value` | -- | | **status** | `sourceState` | -- | | **createdAt** | `timestamp (UTC)` | transformed | | **updatedAt** | `timestamp (UTC)` | transformed | | **completedAt** | `normalTime` | -- | | **customFields** | `(custom fields)` | -- | ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 5 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Ack Alarm **Type:** Write Acknowledges an alarm in the Tridium Niagara system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Alarm ID** | STRING | Yes | Text Box | -- | | **User** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "id": "12345", "user": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Schedule Management This integration supports discovering and managing schedules in the Tridium Niagara system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Tridium Niagara system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Tridium Niagara system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Tridium Niagara API. # Novant Source: https://docs.kodelabs.com/products/integrations/controllers/novant Connect Novant to KODE OS for controller data > Connect Novant to KODE OS for controller data integration ## Overview Use this integration to connect Novant controllers to KODE OS. You can discover devices and points, collect current sensor readings, and pull historical data for trending and analysis. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Novant](https://kodelabs.com/integration/novant/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites * An active account with Novant and access to their API or developer portal * API key or token from the Novant platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Novant platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Novant** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Collect Type** | Yes | dropdown | The data collection method to use | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Novant system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `enum` | enum | | `bool` | bool | | `num` | num | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Novant platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Novant system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Novant API. # OSISoft PI Source: https://docs.kodelabs.com/products/integrations/controllers/osiPi Connect OSISoft PI to KODE OS for controller data > Connect OSISoft PI to KODE OS for controller data integration ## Overview Use this integration to connect OSIsoft PI (PI System) to KODE OS. You can discover assets and points, collect operational sensor data, and bring PI historical series into KODE OS for validation and analytics. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [OSISoft PI](https://kodelabs.com/integration/osisoft-pi/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data * File Validation ## Prerequisites * An active account with OSISoft PI and access to their API or developer portal * Username and password credentials for the OSISoft PI system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **OSISoft PI** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Web IDs** | Yes | text | Comma-separated list of web IDs for PI asset framework elements | | **Version** | No | dropdown | The API or firmware version to use | | **File** | No | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the OSISoft PI system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the OSISoft PI system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the OSISoft PI system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the OSISoft PI API. # Smart Connector Source: https://docs.kodelabs.com/products/integrations/controllers/schneiderElectric Connect Smart Connector to KODE OS for controller data > Connect Smart Connector to KODE OS for controller data integration ## Overview Use this integration to connect Schneider Electric EcoStruxure Smart Connector data to KODE OS. You can discover devices and points, collect sensor and non-sensor data, and receive webhook notifications alongside REST polling. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Smart Connector](https://kodelabs.com/integration/smart-connector/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Smart Connector and access to their API or developer portal * Username and password credentials for the Smart Connector system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Smart Connector platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Smart Connector** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Base ID** | Yes | text | The base identifier for the external system | | **Client Version** | Yes | dropdown | The version of the vendor's API client | | **API Building ID** | No | text | The building or source identifier in the external system | | **Collect Type** | Yes | dropdown | The data collection method to use. Options: `RealTime`, `MQTT Azure` | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Smart Connector system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Smart Connector system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Smart Connector platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Smart Connector system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Smart Connector system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Smart Connector API. # Willow API Source: https://docs.kodelabs.com/products/integrations/controllers/willow Connect Willow API to KODE OS for controller data > Connect Willow API to KODE OS for controller data integration ## Overview Use this integration to connect the Willow API to KODE OS. You can discover base-building BMS equipment and points, collect sensor readings through push delivery, and validate ingested files as part of your data pipeline. | Property | Value | | - | - | | **System Type** | Controller | | **Communication** | REST | | **Collection** | Push | | **Collection Mode** | HISTORICAL | See [Willow API](https://kodelabs.com/integration/willow/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * File Validation ## Prerequisites * An active account with Willow API and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Willow API developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Willow API developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Willow API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Willow API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time HVAC, lighting, and building automation data from a single dashboard * Set up automated alerts when equipment deviates from normal operating parameters * Track energy consumption and optimize building performance with historical trend data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Willow developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Willow system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Willow API. # Bosch Orion Source: https://docs.kodelabs.com/products/integrations/elevators/bosch Connect Bosch Orion to KODE OS for elevator system data > Connect Bosch Orion to KODE OS for elevator system data integration ## Overview Use this integration to connect Bosch Orion elevator monitoring to KODE OS. REST polling surfaces cab status, faults, and operational data for emergency support and maintenance visibility. | Property | Value | | - | - | | **System Type** | Elevator System | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Bosch Orion](https://kodelabs.com/integration/bosch/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Bosch Orion and access to their API or developer portal * Username and password credentials for the Bosch Orion system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Bosch Orion** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Location IDs** | Yes | text | Comma-separated list of location identifiers to monitor | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Bosch Orion system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Bosch Orion, KODE OS maps them to the following device types and data points: ### Elevator Canonical Type: `elevator` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `isConnected` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 2 | `Current Floor` | Floor the elevator is currently on | -- | No | Polling | | 3 | `Trips Count Last 24h` | Number of trips completed in the last 24 hours | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including isConnected, Current Floor, Trips Count Last 24h, collected at regular intervals from connected devices ### Door Data Door access and usage data including open/close events and access counts ### Movement Data Movement tracking and people flow data including direction, count, and location ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Bosch Orion data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **name** | mapped by connector | -- | | **description** | `eventText` | -- | | **priority** | `prio` | -- | | **status** | mapped by connector | -- | | **deviceId** | `serialNumber` | -- | | **deviceName** | `"Elevator " + serialNumber` | -- | | **location** | `addressLine1` | -- | | **updatedBy** | `modifiedBy` | -- | | **createdAt** | `alarmDateTimeUtc` | -- | | **updatedAt** | `modifiedDateTimeUtc` | -- | | **customFields** | mapped by connector | -- | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Alarm** -- Default polling: 10 minutes (min: 10 minutes, max: 1 days) * **Movement** -- Default polling: 10 minutes (min: 10 minutes, max: 1 days) * **BoschDoorData** -- Default polling: 10 minutes (min: 10 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor elevator call counts, wait times, and operational status * Track elevator service intervals and maintenance needs * Correlate elevator usage patterns with building occupancy data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Bosch Orion system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Bosch Orion system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Bosch Orion API. # Kone Source: https://docs.kodelabs.com/products/integrations/elevators/kone Connect Kone to KODE OS for elevator system data > Connect Kone to KODE OS for elevator system data integration ## Overview Use this integration to connect KONE elevator and people-flow data to KODE OS. REST and webhooks deliver real-time lift status, events, and operational metrics for your connected assets. | Property | Value | | - | - | | **System Type** | Elevator System | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Kone](https://kodelabs.com/integration/kone/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Kone and access to their API or developer portal * API key or token from the Kone platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Kone developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Kone platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kone** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Devices and Points | Point | Display Name | | - | - | | `com.kone.equipment.availability.v1` | com kone equipment availability v1 | | `com.kone.equipment.status.v1` | com kone equipment status v1 | | `Equipment ID` | Equipment ID | ## What Data You Get ### Movement Data Movement tracking and people flow data including direction, count, and location ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results > [!NOTE] > > Audit fields depend on the KONE People Flow event types your site publishes. The table below shows the standard KODE OS audit field set; not every field is populated for every elevator event. KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Movement** * **Audit Log** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor elevator call counts, wait times, and operational status * Track elevator service intervals and maintenance needs * Correlate elevator usage patterns with building occupancy data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Kone developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Kone platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Kone system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kone API. # Safeline Source: https://docs.kodelabs.com/products/integrations/elevators/safeline Connect Safeline to KODE OS for elevator system data > Connect Safeline to KODE OS for elevator system data integration ## Overview Use this integration to stream Safeline elevator telemetry into KODE OS via webhooks. Push delivery keeps snapshot status and event data current without polling. | Property | Value | | - | - | | **System Type** | Elevator System | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Safeline](https://kodelabs.com/integration/bosch-2/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Safeline and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Safeline platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Safeline** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Devices and Points When you discover devices from Safeline, KODE OS maps them to the following device types and data points: ### Elevator Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `velocity` | Current travel velocity | -- | No | Webhook | | 2 | `currentFloor` | Floor the elevator is currently on | -- | No | Webhook | | 3 | `state` | Current operating state | -- | No | Webhook | | 4 | `connectionStatus` | Device connectivity status | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including velocity, currentFloor, state, connectionStatus, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Safeline data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **name** | `alarmName` | -- | | **description** | mapped by connector | -- | | **id** | `alarm.correlationId` | transformed | | **status** | `alarm.state` | transformed | | **location** | `site.name` | transformed | | **deviceId** | `device.id` | transformed | | **deviceName** | `device.serialNumber` | transformed | | **createdAt** | mapped by connector | transformed | | **customFields** | `(custom fields)` | -- | | **name** | `alarmName` | -- | | **description** | mapped by connector | -- | | **id** | `alarm.correlationId` | transformed | | **status** | `alarm.state` | transformed | | **location** | `site.name` | transformed | | **deviceId** | `facility.id` | transformed | | **deviceName** | `facility.name` | transformed | | **createdAt** | mapped by connector | transformed | | **customFields** | `(custom fields)` | -- | ### Polling Schedule * **Point History** * **Alarm** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor elevator call counts, wait times, and operational status * Track elevator service intervals and maintenance needs * Correlate elevator usage patterns with building occupancy data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Safeline platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Safeline platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Safeline system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Safeline API. # TKE Elevator Source: https://docs.kodelabs.com/products/integrations/elevators/tke Connect TKE Elevator Service Record API 3.0 to KODE OS for elevator and work order data > Connect TKE Elevator to KODE OS for elevator system data integration ## Overview Use this integration to connect TK Elevator equipment to KODE OS. You discover assets, collect performance and fault data, and retrieve service records through Service Record API 3.0. | Property | Value | | - | - | | **System Type** | Elevator System | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [TKE Elevator](https://kodelabs.com/integration/tk-elevator/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites To integrate with the TKE API, ensure you have the following details: * An active account in [https://developer.ams.tkelevator.com](https://developer.ams.tkelevator.com) with the appropriate access permissions. * Valid username and password credentials for the TKE platform. If you don’t have an account, then reach out to your local contact: [https://www.tkelevator.com/global-en/contact/local-contact/](https://www.tkelevator.com/global-en/contact/local-contact/) Password Tenant ID\* Obtain by emailing [integrations@kodelabs.com](mailto:integrations@kodelabs.com) API Building ID\* Fields marked with an asterisk \* are mandatory for completing the integration. ## Generate API Credentials Steps to Obtain URL 4 * Go to [https://developer.ams.tkelevator.com](https://developer.ams.tkelevator.com) and click **Sign In** at the top-right corner. * Click the MAX Customer Services AD button and log in using your username and password. * Once logged in, navigate to your Profile. * Scroll down to the Subscriptions section. * Under the Product Add-on IoT – 3.0 subscription, click Show next to the Primary Key, and copy your Subscription Key Steps to Obtain URL * Go to tab APIs * Click one of the options from the API dropdown menu i.e MAX Elevator Statistics API - 3.0 * Copy the base URL from the request After completing the steps above, your Subscription Key, and URL will be used in the next step. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **TKE Elevator** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Scope** | Yes | text | The OAuth scope for API access | | **Subscription Key** | Yes | password | The subscription key for the vendor's API | | **Tenant ID** | Yes | text | The tenant identifier in the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the TKE Elevator system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from TKE Elevator, KODE OS maps them to the following device types: * **Elevator** (`elevator`) | Point | Display Name | | - | - | | `equipmentStatus` | equipmentStatus | | `connectivityStatus` | connectivityStatus | | `currentFloor` | currentFloor | | `currentTripDirection` | currentTripDirection | | `Equipment Status` | Equipment Status | | `Connectivity Status` | Connectivity Status | | `Current Floor` | Current Floor | | `Current Trip Direction` | Current Trip Direction | | `Relevel` | Relevel | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Work Orders Maintenance and service requests include status, priority, service category, technician, timestamps, and resolution details. KODE OS maps TKE Elevator data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `serviceRecordId` | -- | | **category** | `categoryLocale` | Localized service category | | **priority** | `ticketPriority` | Ticket priority from Service Record API 3.0 | | **description** | `ticketDescriptionLocale` | -- | | **status** | `ticketStatus` | -- | | **assignedTo** | `technicianName` | -- | | **createdAt** | derived value | transformed | | **startedAt** | derived value | transformed | | **completedAt** | derived value | transformed | | **duration** | mapped by connector | -- | | **resolutionDetails** | `workDescriptionLocale` | -- | | **assetId** | `unitId` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor elevator call counts, wait times, and operational status * Track elevator service intervals and maintenance needs * Correlate elevator usage patterns with building occupancy data ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the TKE Elevator developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the TKE Elevator system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the TKE Elevator API. # Blink Source: https://docs.kodelabs.com/products/integrations/ev-charging/blink Connect Blink to KODE OS for electric vehicle charging data > Connect Blink to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect Blink EV chargers to KODE OS. You discover stations and connectors, then collect session, energy, and status data over REST with historical retention for utilization analysis. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Blink and access to their API or developer portal * API key or token from the Blink platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Blink platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Blink** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Location ID** | Yes | text | The location identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Blink system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **ChargePointSessions** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Blink platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Blink system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Blink API. # ChargePoint Source: https://docs.kodelabs.com/products/integrations/ev-charging/chargePoint Connect ChargePoint to KODE OS for electric vehicle charging data > Connect ChargePoint to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect ChargePoint EV charging to KODE OS. Discovery and REST polling bring live station status, sessions, and operational details into the platform for portfolio oversight. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [ChargePoint](https://kodelabs.com/integration/chargepoint/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with ChargePoint and access to their API or developer portal * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [ChargePoint API services endpoint](https://webservices.chargepoint.com/webservices/chargepoint/services/4.1) ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **ChargePoint** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the ChargePoint system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from ChargePoint, KODE OS maps them to the following device types and data points: ### EV Charging Station Canonical Type: `chargingStation` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Reservable` | **True** -- Reservable is active / **False** -- Reservable is not active | -- | No | -- | Polling | | 2 | `Voltage` | Voltage reading (V) | V | No | `run_voltage_sensor` | Polling | | 3 | `Current` | Electrical current reading (A) | A | No | `run_current_sensor` | Polling | | 4 | `Power` | Current power reading (kW) | kW | No | `run_power_sensor` | Polling | | 5 | `AVAILABLE` | Current charger availability status | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including Reservable, Voltage, Current, Power, AVAILABLE, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **ChargePointAlarms** -- Default polling: 1 days (min: 1 days, max: 1 days) * **ChargePointSessions** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the ChargePoint platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the ChargePoint system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the ChargePoint API. # Flash Parking EV Charging Source: https://docs.kodelabs.com/products/integrations/ev-charging/flashParkingEVCharging Connect Flash Parking EV Charging to KODE OS for electric vehicle charging data > Connect Flash Parking EV Charging to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect Flash Parking EV charging to KODE OS. REST polling collects charger status and related non-sensor EV data per configured location. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Flash Parking EV Charging](https://kodelabs.com/integration/flash-parking/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Flash Parking EV Charging and access to their API or developer portal * Username and password credentials for the Flash Parking EV Charging system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Flash Parking EV Charging** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## What Data You Get ### EV Charging Sessions Electric vehicle charging session data including energy consumption (kWh), pricing, parking times, tower/port identification, and revenue KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique charging session identifier | | **Station** | Charging station name | | **Port** | Port number on the charging station | | **Energy (kWh)** | Total energy delivered in kilowatt-hours | | **Location** | Physical location of the charger | | **State** | Session state (Charging, Completed, Error) | | **Price** | Session cost | | **Currency** | Price currency | | **User** | Person who initiated the session | | **Started At** | Session start timestamp | | **Ended At** | Session end timestamp | | **End Reason** | Reason the session ended | ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) * **EvCharging** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Flash Parking EV Charging system. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Flash Parking EV Charging API. # Monta Source: https://docs.kodelabs.com/products/integrations/ev-charging/monta Connect Monta to KODE OS for electric vehicle charging data > Connect Monta to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect Monta-managed charge points to KODE OS. REST discovery and polling plus webhooks keep station state and events synchronized for operations and automation. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Monta](https://kodelabs.com/integration/monta/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Monta and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Monta developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Monta developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Monta platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Monta** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Team ID** | Yes | password | The team identifier in the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Monta system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Monta, KODE OS maps them to the following device types and data points: ### EV Charging Station Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Power` | Current power reading (kW) | kW | No | `run_power_sensor` | Webhook | | 2 | `Type` | Charger or connector type | -- | No | -- | Webhook | | 3 | `State` | Current operating state | -- | No | -- | Webhook | | 4 | `Energy` | Cumulative energy consumption (kWh) | kilowattPerHour | No | `run_energy_accumulator` | Webhook | | 5 | `Cable Plugged` | **True** -- Cable Plugged is active / **False** -- Cable Plugged is not active | -- | No | -- | Webhook | ## What Data You Get ### Point History Time-series readings including Power, Type, State, Energy, Cable Plugged, collected at regular intervals from connected devices ### Polling Schedule * **Point History** * **ChargePointSessions** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Monta developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Monta platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Monta system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Monta system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Monta API. # Unico Source: https://docs.kodelabs.com/products/integrations/ev-charging/unico Connect Unico to KODE OS for electric vehicle charging data > Connect Unico to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect Unico EV charging to KODE OS. You discover chargers, collect live readings, and ingest related operational records over REST. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Unico](https://kodelabs.com/integration/unico/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Unico and access to their API or developer portal * API key or token from the Unico platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Unico platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Unico** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | password | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Unico system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Unico, KODE OS maps them to the following device types and data points: ### EV Charging Station Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `active` | Current activation status | -- | No | `value` | Polling | | 2 | `iMax` | Maximum current limit (A) | A | No | -- | Polling | | 3 | `iMin` | Minimum current threshold (A) | A | No | -- | Polling | | 4 | `state` | **Unknown** -- state cannot be determined / **Unplugged** -- vehicle is not connected / **PluggedIn** -- vehicle is connected but not charging / **Charging** -- vehicle is actively charging / **VentErr** -- ventilation error / **DiodeErr** -- diode check failure / **GfciFault** -- ground fault detected / **NoGround** -- grounding issue / **RelayStuck** -- relay is stuck / **GfciTestFail** -- GFCI self-test failed / **OverTemp** -- over-temperature condition / **EnabledUnknown** -- enabled but state unknown / **SleepTest** -- in sleep/test mode / **Preparing** -- preparing to charge / **Finishing** -- finishing charge session / **Restarting** -- restarting / **UnknownFault** -- unknown fault condition | -- | No | -- | Polling | | 5 | `enabled` | **off** -- disabled / **session** -- enabled for current session only / **always** -- always enabled | -- | No | -- | Polling | | 6 | `boost` | **True** -- boost mode is enabled / **False** -- boost mode is disabled | -- | No | -- | Polling | | 7 | `status` | Current operating status | -- | No | -- | Polling | | 8 | `healthy` | **True** -- device is healthy and operating normally / **False** -- device health issue detected | -- | No | `connection_status` | Polling | | 9 | `current` | Electrical current reading (A) | A | No | `run_current_sensor` | Polling | | 10 | `lastOn` | Timestamp of the last power-on event | -- | No | -- | Polling | | 11 | `lastOff` | Timestamp of the last power-off event | -- | No | -- | Polling | | 12 | `watts` | Power consumption (W) | watts | No | `run_power_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including active, iMax, iMin, state, enabled, boost, status, healthy, and 4 more, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Unico data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **name** | `type` | -- | | **description** | `content` | -- | | **deviceId** | `userUuid` | -- | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | conditional | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Alarm** -- Default polling: 1 hours (min: 1 hours, max: 1 days) * **ChargePointSessions** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Unico platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Unico system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Unico API. # Zaptec Source: https://docs.kodelabs.com/products/integrations/ev-charging/zaptec Connect Zaptec to KODE OS for electric vehicle charging data > Connect Zaptec to KODE OS for electric vehicle charging data integration ## Overview Use this integration to connect Zaptec EV chargers to KODE OS. You discover equipment, poll charger status and energy metrics, and collect supporting non-sensor data over REST. | Property | Value | | - | - | | **System Type** | Electric Vehicle Charging | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Zaptec and access to their API or developer portal * Username and password credentials for the Zaptec system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Zaptec** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Zaptec system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Zaptec, KODE OS maps them to the following device types: * **EV Charging Station** (`chargingStation`) | Point | Display Name | | - | - | | `commit_end_date_time` | commit end date time | | `isOnline` | isOnline | | `active` | active | | `signedMeterValueKwh` | signedMeterValueKwh | | `operatingMode` | operatingMode | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 10 minutes (min: 10 minutes, max: 1 hours) * **ChargePointSessions** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor EV charger availability, session data, and energy delivered * Track charging revenue and utilization across stations * Generate reports on EV infrastructure usage and demand patterns ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Zaptec system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Zaptec system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Zaptec API. # What are Integrations? Source: https://docs.kodelabs.com/products/integrations/get-started/introduction Connect 200+ external systems to KODE OS to discover, collect, and act on building data > Connect external systems to KODE OS to discover, collect, and act on building data KODE OS integrations connect your building systems to a single platform. You configure a connector, discover devices and points, and start collecting data from the `Data Sources` page in your building. With 200+ supported systems across access control, metering, occupancy, lighting, HVAC, and more, integrations give you a consistent view of every system in your portfolio. ## What you can do KODE OS integrations support five core capabilities. Each integration may support one or more of these depending on the external system. > [card] [Discover](/products/integrations/capabilities/discovery) > > Automatically find devices, points, schedules, and assets from connected systems > [card] [Collect data](/products/integrations/capabilities/data-collection) > > Pull or receive sensor readings, work orders, alarms, and events on a schedule or in real time > [card] [Actions](/products/integrations/capabilities/actions) > > Send commands to devices, create work orders, or update records in external systems > [card] [Schedules](/products/integrations/capabilities/schedules) > > Manage time-based configurations like HVAC programs and lighting routines > [card] [MQTT](/products/integrations/capabilities/mqtt) > > Connect IoT devices using lightweight publish/subscribe messaging ### Discover Discovery is a user-initiated process that finds devices, points, schedules, and other assets from a connector. You do not configure each item by hand. KODE OS queries the external system and lists available sensors, cameras, door readers, meters, and more. * **Devices and points**: Available devices and their data points * **Schedules**: Schedules or calendars already configured in the third-party system (when supported) * **Assets**: Non-sensor metadata objects such as furniture, network equipment, or safety equipment See the [Discovery guide](/products/integrations/capabilities/discovery). ### Collect data Collect data means gathering information about discovered entities. Depending on the external system, this can happen in two ways: * **Scheduled pull**: KODE OS connects to the connector at regular intervals. Protocols include REST, SOAP, FTP/SFTP, SDKs, and OpenSSL/TCP. * **Real-time push**: The third-party system sends data as events occur. Protocols include MQTT, WebSockets, and webhooks. Data collection supports three modes: * **Snapshot**: The current state at a specific moment * **Delta**: Only changes since the last collection * **Historical**: A complete log of past values over time See the [Data collection guide](/products/integrations/capabilities/data-collection). ### Actions Actions are commands sent to devices or requests made to external systems to change a value or trigger an event. KODE OS supports: * **Point actions**: Set a new value on a point (for example, thermostat temperature or light on for two hours) * **Entity actions**: Create or update records in external systems (for example, a work order) * **Schedule actions**: Create, update, or delete schedules in the external system See the [Actions guide](/products/integrations/capabilities/actions). ### Schedules Schedules manage time-based configurations in external systems. KODE OS supports two schedule types: * **Calendar schedules**: Exceptions or one-time events such as holidays, maintenance windows, and temporary overrides * **Weekly schedules**: Recurring routines for each day of the week such as business hours and off-hours settings See the [Schedules guide](/products/integrations/capabilities/schedules). ## How it works The integration lifecycle follows the same flow for every external system. ```mermaid theme={"theme":{"light":"github-light","dark":"github-dark"}} flowchart LR A["Browse API Catalog"] --> B["Add connector"] B --> C["Configure connector"] C --> D["Discover devices and points"] D --> E["Map with ontology"] E --> F["Collect data"] F --> G["Take actions"] ``` To walk through this flow in the product, follow the [Quickstart](/products/integrations/get-started/quickstart). ## Core concepts These terms appear throughout KODE OS integrations documentation. ### API An API (Application Programming Interface) is a defined way for software systems to exchange data and commands. KODE OS uses APIs to talk to external building systems. ### Connector A connector is the configured connection from KODE OS to one external system. In the UI, connectors live on the `Data Sources` page. Older labels may still say datasource. Prefer connector in documentation and conversation. Different vendors use different protocols such as MQTT, Modbus, or HTTPS. Each connector type knows how to speak to that vendor or system family. ### Device A device is the physical or logical piece of equipment you monitor or control, such as a thermostat, light fixture, or motion sensor. Devices connect to KODE OS through a connector. ### Point A point is an individual data value, measurement, or control option on a device. Examples include a temperature reading, a turn-on command, or a door-open status. ### Sensor data and non-sensor data **Sensor data** is measurable, often time-stamped values from device points. Examples include room temperature, occupancy status, air quality, and water flow. **Non-sensor data** is building information that is not generated by a physical sensor. Examples include reservations, visitor entries, alarms, and completed inspection checklists. ### Schedules A schedule defines time-based rules for automating behavior. It tells the system what to run, when to run it, and how often. Examples include lights off at 8 PM and HVAC start at 6 AM on weekdays. ### Ontology Ontology is the common vocabulary KODE OS uses to name and organize devices, points, and other entities from different vendors. Vendors often use different labels for the same concept: | Third-party system | What they call it | | - | - | | System A | `temp_sensor` | | System B | `temperature probe` | | System C | `TS01` | Ontology maps those names to a standard type in Cloud BMS. For example, all three map to a Temperature Sensor device type with a Temperature point type. The ontology workflow is: 1. **Discover** — KODE OS finds devices and points and saves each native identifier 2. **Map** — Each object maps to a standardized type, either during discovery or manually in Cloud BMS 3. **Operate** — You collect data, trigger actions, and monitor devices with consistent names You apply ontology in `Cloud BMS` after you discover devices from a connector. ### Dynamic APIs Some systems, such as Niagara or BACnet servers, do not expose a fixed list of device and point types. Available objects appear at runtime when you discover them. For dynamic integrations: 1. **Connect** — KODE OS connects to the external system 2. **Discover** — KODE OS reads available objects 3. **Map** — You often map each object to a standard type manually in Cloud BMS 4. **Operate** — After mapping, you collect data and run actions as with any other integration > [!NOTE] > > Check the specific integration page to see whether your system uses a dynamic or fixed API structure. ## Communication protocols KODE OS uses different protocols depending on the external system. | Protocol | Role | | - | - | | **REST** | Common web API style over HTTPS using methods such as GET, POST, PUT, and DELETE | | **SOAP** | XML-based messaging, often used by legacy systems and defined by a WSDL | | **Webhook** | The external system pushes an HTTP request to KODE OS when an event occurs | | **MQTT** | Lightweight publish/subscribe messaging for constrained devices and low-bandwidth networks | | **WebSocket** | Full-duplex real-time messaging over a single TCP connection | | **SDK** | Vendor libraries that call the external system directly | | **OpenSSL / TCP** | Raw socket communication for custom or low-level integrations | | **SFTP / FTP** | Scheduled file transfer for systems that exchange CSV or XML files | | **Modbus / BACnet** | Building automation protocols for HVAC units, meters, and controllers | See [MQTT integrations](/products/integrations/capabilities/mqtt) for broker, topic, and QoS details. ## Environments Connectors can run in the cloud or on premises. * **Cloud**: Hosted on platforms such as AWS, GCP, or Azure and reached over the internet * **Local (on-premises)**: Installed in the building or client network; may require VPN access to KODE OS Common infrastructure pieces include servers, databases, network paths, IP addresses or URLs, credentials or certificates, firewalls, and API gateways. ## Next steps > [card] [Quickstart](/products/integrations/get-started/quickstart) > > Connect your first external system and verify data flow > [card] [Managing connectors](/products/integrations/get-started/managing-connectors) > > Configure, test, and monitor connectors day to day > [card] [Integrations catalog](/products/integrations/catalog) > > Find your integration among 200+ supported systems > [card] [Discovery](/products/integrations/capabilities/discovery) > > Understand how device, point, schedule, and asset discovery works # Managing connectors Source: https://docs.kodelabs.com/products/integrations/get-started/managing-connectors Configure, test, monitor, and manage your integration connectors in KODE OS > Configure, test, monitor, and manage your integration connectors in KODE OS A connector is the configured instance of an integration that connects KODE OS to a specific external system. Connectors appear on the `Data Sources` page. This guide covers the full lifecycle of a connector, from initial setup through daily operations. If you have not created a connector yet, start with the [Quickstart](/products/integrations/get-started/quickstart). ## Adding a connector The connector setup follows a three-page configuration flow. ### Page 1 — Credentials and settings Enter the required connection details for the integration. The exact fields vary by integration, but typically include: * **URL** — The base URL or IP address of the external system * **Authentication** — Username and password, API key, OAuth client credentials, or certificates * **Dynamic fields** — Vendor lists such as sites, locations, stores, and similar values, loaded after you select `Validate Credentials` ### Validate credentials After you select `Validate Credentials`, KODE OS loads vendor fields in the background and shows progress. Vendor fields include sites, locations, stores, and similar lists. Errors state the cause, such as `authentication failed`, `vendor timed out`, or `vendor error`, and you can retry. When a vendor returns no options for a multi-select vendor field, type comma-separated IDs into that field and save. Click `Next` to proceed once the fields are complete. ### Page 2 — Entity enablement Toggle which data entities you want this connector to collect. Each integration supports one or more entity types: * **Point History** — Time-series sensor data * **Audit Log** — Access and security events * **Alarm** — Alert and fault notifications * **Work Order** — Maintenance task records * **Schedule Sync** — Schedule state synchronization Entity toggles are enabled by default. Disable any entity types you do not need for this connector. ### Page 3 — Polling frequency Configure how often KODE OS collects data for each enabled entity: | Setting | Description | | - | - | | **Unit** | Time unit for the interval (seconds, minutes, hours, days) | | **Interval** | How many units between each collection cycle | | **Start At** | The time of day to begin the first collection (HH:mm format; do not use 00:00) | Each integration defines minimum and maximum polling intervals. The configuration prevents values outside the allowed range. If **Collect Data Ping** is enabled, you can also configure: * The threshold for marking connectors, devices, or points as inactive when no data is received * The ping frequency for health checks Collect Data Ping is a health check that watches whether data still arrives on schedule. When it is enabled, KODE OS can mark connectors, devices, or points inactive if no data arrives within the threshold you set. ## Connector detail page After you create a connector, the connector detail page is the central place to manage it. ### Status and controls | Control | Description | | - | - | | **Current Status** | Shows whether the connector is currently up or down | | **Enable / Disable** | Toggle to activate or deactivate the connector (requires confirmation) | | **Test Connection** | Verify that the credentials and configuration are valid | | **Discover** | Start discovery for devices, schedules, or assets | | **Refresh Cache** | Manually refresh the connector's cached data | | **Delete** | Permanently remove the connector (requires confirmation) | ### Discovery statistics | Statistic | Description | | - | - | | **Devices** | Count of discovered, saved, and templated devices, with last discovery timestamp | | **Schedules** | Count of discovered and saved schedules, with last discovery timestamp | | **Assets** | Count of discovered and saved assets, with last discovery timestamp | Templated devices are devices that already have an ontology or device template applied in Cloud BMS. ### Entity details Each enabled entity type has its own section showing: * **Collection chart** — Timeline of data collection count over time * **Enable / Disable** — Toggle the entity on or off (requires confirmation) * **Polling frequency** — Current interval and controls to change it * **Non-sensor table** — For non-sensor entities (alarms, audit logs, work orders), a table of collected records Each non-sensor data table shows which date column the start and end range applies to. Examples include `Created At (Local)` and `Collected At`. Entities without a date filter column show no label. ### Timeseries chart A chart of the connector's collected time-series data over time. Use it as a quick visual check of data flow health. ### Error logs A table of recent errors from collection, authentication, or discovery. Each entry includes a timestamp, error type, and message. ### Activity log A historical log of operations on this connector, including configuration changes, discovery runs, and status changes. ### Webhook configuration For webhook-based integrations, this section displays: * The webhook URLs that the external system should send data to * The expected payload structure for each URL * Verification status ## Testing a connection Before you rely on a connector for data collection, test it. **1. Open the connector** Navigate to the connector detail page from `Data Sources`. **2. Run Test Connection** Click `Test Connection`. KODE OS authenticates with the external system using the configured credentials. **3. Review the result** The result shows Success or Failed with an error message. A successful test confirms that: * The URL is reachable from KODE OS * The credentials are valid * The API version or driver version is compatible * The external system is responding correctly ## Modifying a connector **1. Open the connector** Navigate to the connector detail page. **2. Edit settings** Update credentials, polling frequency, or entity enablement as needed. **3. Save and retest** Save the changes, then run `Test Connection` to verify the updated settings. ## Deleting a connector > [!WARNING] > > Deleting a connector is permanent and cannot be undone. All associated devices, points, and collected data references are removed. **1. Open the connector** Navigate to the connector detail page. **2. Delete** Click `Delete` and confirm in the dialog. ## Troubleshooting > [accordion] Test connection fails > > Verify the URL is correct and reachable from the KODE OS network. Check that firewalls allow outbound connections on the required port. Ensure the credentials have not expired. For OAuth integrations, you may need to regenerate the client secret. > [accordion] Connector shows Down status > > A down status means the last collection attempt failed. Check the error logs on the connector detail page for specific messages. Common causes include expired credentials, network changes, or the external system being temporarily unavailable. > [accordion] Entities are not collecting data > > Verify the entity is enabled on the connector detail page. Check that the polling frequency is within the allowed range. If the entity was recently enabled, wait for the first polling interval to pass before data appears. > [accordion] Dynamic fields are not appearing > > Select `Validate Credentials` after you enter the connection details. KODE OS loads vendor fields in the background and shows progress. > > If the load fails, the error states the cause, such as `authentication failed`, `vendor timed out`, or `vendor error`. You can retry after you read that message. > > When a vendor returns no options for a multi-select vendor field, type comma-separated IDs into that field and save. > [accordion] Connector shows Down but individual devices are still collecting > > The connector status and individual device statuses are independent. The connector status verifies that the connection to the external API works and that the credentials are valid. Individual device statuses reflect whether each device is reporting data. A connector can show Up while a device shows Down, and the reverse can also happen. If the connector status is Down, check credentials and network connectivity first. # Quickstart Source: https://docs.kodelabs.com/products/integrations/get-started/quickstart Connect your first external system to KODE OS and start collecting data in minutes > Connect your first external system to KODE OS and start collecting data This guide walks you through connecting an external system to KODE OS, from finding the right integration to verifying data flow. The process takes a few minutes once you have your vendor credentials ready. ## Before you begin > [!NOTE] > > Make sure you have the following before you start: > > * **KODE OS access** — a user account with permission to manage data sources in the target building > * **Vendor credentials** — the API key, username and password, OAuth client ID and secret, or certificates required by the external system (check the specific [integration page](/products/integrations/catalog) for what your vendor requires) > * **Network connectivity** — KODE OS must reach the external system's API endpoint (verify firewall rules and VPN access for on-prem systems) **1. Open Data Sources** Navigate to your building in KODE OS. In the left-side menu, click `Data Sources`. This page displays any connectors you have already configured for this building. **2. Find your integration** Click `API Catalog` in the left menu. Browse integrations by system type (access control, metering, occupancy, lighting, and more) or use the search bar to find your vendor by name. Click the integration to view its supported entities, collection schedules, and available data fields. > [!TIP] > > Not sure which integration to use? Browse the full [Integrations catalog](/products/integrations/catalog) to see all 200+ supported systems organized by category. **3. Add a connector** Click `+ Add Datasource` at the top right of the integration detail page. A three-page setup flow opens. **Page 1 — Credentials and settings** Enter the connection details for the external system. The required fields vary by integration but typically include: * **URL** — base URL or IP address of the external system * **Authentication** — username and password, API key, OAuth credentials, or certificates * **Dynamic fields** — vendor lists such as sites, locations, stores, and similar values After you select `Validate Credentials`, KODE OS loads those vendor fields in the background and shows progress. Errors state the cause, such as `authentication failed`, `vendor timed out`, or `vendor error`, and you can retry. When a vendor returns no options for a multi-select vendor field, type comma-separated IDs into that field and save. Click `Next` once the fields are complete. **Page 2 — Entity enablement** Toggle which data entities you want to collect. Options vary by integration and may include Point History, Work Orders, Alarms, Audit Logs, or Schedule Sync. All available entities are enabled by default. Disable any you do not need. **Page 3 — Polling frequency** Set how often KODE OS polls each enabled entity. Configure the time unit (seconds, minutes, hours, or days), the interval, and the start time. Each integration defines minimum and maximum polling intervals. Click `Save` to create the connector. **4. Test the connection** On the connector detail page, click `Test Connection`. KODE OS authenticates with the external system using your credentials and verifies that the API endpoint is reachable. > [!TIP] > > A successful test confirms the URL is reachable, credentials are valid, and the external system is responding correctly. If the test fails, check that the URL is correct, credentials have not expired, and firewall rules allow outbound connections from KODE OS to the external system. **5. Run discovery** Click `Discover` on the connector detail page. KODE OS queries the external system and returns a list of available devices, data points, schedules, and assets. Review the discovered items and select which ones to register in KODE OS. Selected items are saved and ready for data collection. > [!NOTE] > > Not all integrations support discovery. Webhook-only and MQTT integrations receive data as it arrives and do not require a discovery step. **6. Verify data flow** After the first polling interval passes, check the connector detail page: * The **collection chart** shows data volume over time * The **current status** indicator shows whether the connector is up * Individual **entity sections** display collected records or time-series data If data appears in the chart, your integration is working. Navigate to `Cloud BMS` to map ontology to your discovered devices for consistent naming across your building portfolio. ## What's next > [card] [Managing connectors](/products/integrations/get-started/managing-connectors) > > Learn how to modify, monitor, and troubleshoot your connectors > [card] [Integrations catalog](/products/integrations/catalog) > > Browse all 200+ supported integrations by system category > [card] [Discovery](/products/integrations/capabilities/discovery) > > Understand how device, point, schedule, and asset discovery works > [card] [Data collection](/products/integrations/capabilities/data-collection) > > Learn about pull vs. push collection and snapshot, delta, and historical data types # KODE glossary Source: https://docs.kodelabs.com/products/integrations/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Airthings Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/airthings Connect Airthings to KODE OS for indoor environmental quality, occupancy data > Connect Airthings to KODE OS for indoor environmental quality, occupancy data integration ## Overview Use this integration to connect Airthings to KODE OS. You can discover devices and points, collect indoor air quality metrics with hybrid REST and webhook collection, and align sensor readings with occupancy context in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality, Occupancy | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Airthings](https://kodelabs.com/integration/airthings/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * Collect Historical Data ## Prerequisites To integrate with the Airthings API, ensure you have the following details: * Airthings URL: [https://ext-api.airthings.com](https://ext-api.airthings.com) * Airthings Auth URL: [https://accounts-api.airthings.com](https://accounts-api.airthings.com) * Account ID: Found on the Overview Page in the Airthings Developer Portal. * Client ID: Generated when registering your application in the Airthings Developer Portal. * Client Secret: Generated along with the Client ID in the Airthings Developer Portal. ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Airthings API getting started](https://developer.airthings.com/docs/api/getting-started) * [Airthings OAuth authorization](https://developer-business.airthings.com/docs/api-authorization) ## Generate API Credentials 1. Log in to the Airthings developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Webhook Overview * Copy this URL for the next steps. * Fill in the required fields: * HTTP Header Key: Enter Authorization. * HTTP Header Value: (You will input the authentication key once it's provided by KODE Team.) ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Airthings** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Account ID** | Yes | password | The account or organization ID from the vendor platform | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Airthings system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Airthings, KODE OS maps them to the following device types: * **Air Quality Sensor** (`airQuality`) | Point | Display Name | Unit | Ontology Field | | - | - | - | - | | `temp` | Temperature | °C | `zone_air_temperature_sensor` | | `humidity` | Humidity | %RH | `zone_air_humidity_sensor` | | `co2` | CO2 | ppm | `co2_concentration_detection_sensor` | | `tvoc` | Total VOC | ppb | `voc_concentration_detection_sensor` | | `pm1` | PM1 | µg/m³ | -- | | `pm25` | PM2.5 | µg/m³ | `pm25_concentration_detection_sensor` | | `pm10` | PM10 | µg/m³ | `pm10_concentration_detection_sensor` | | `pressure` | Barometric Pressure | hPa | -- | | `lux` | Light Level | lux | `illuminance_sensor` | | `light` | Light Level (%) | % | -- | | `hourlyRadon` | Radon (Hourly) | pCi/L | -- | | `radonShortTermAvg` | Radon (Short-term Avg) | pCi/L | -- | | `soundLevelA` | Sound Level | dB(A) | `noise_sensor` | | `airflow` | Airflow | m³/h | -- | | `airExchangeRate` | Air Exchange Rate | ACH | -- | | `rssi` | Signal Strength | dBm | -- | | `batteryPercentage` | Battery | % | -- | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 3 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Airthings developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Airthings platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Airthings system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Airthings system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Airthings API. # Atlasen Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/atlasen Connect Atlasen to KODE OS for indoor environmental quality data > Connect Atlasen to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Atlasen to KODE OS. You can discover air quality devices and points, pull snapshot environmental data over REST, and monitor IEQ readings from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Atlasen](https://kodelabs.com/integration/atlasen/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Atlasen and access to their API or developer portal * API key or token from the Atlasen platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Atlasen platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Atlasen** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Atlasen system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 30 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Atlasen platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Atlasen system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Atlasen API. # Attune Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/attune Connect Attune to KODE OS for indoor environmental quality data > Connect Attune to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Attune to KODE OS. You can discover sensors and devices, receive environmental IoT data through webhook push collection with snapshot mode, and monitor indoor conditions from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * File Validation ## Prerequisites To integrate with the Attune API, ensure you have the following details: * An active account in [https://my.senseware.co](https://my.senseware.co) with the appropriate access permissions. * Valid username and password credentials for the Attune platform. ## Configure Webhook Steps to Enable Attune Data Forward * Log in to the Attune Platform using your username and password * From Left side bar Tools click Forwards button * Click button “Add Data Forward” * Configure the basic settings for your Data Forward: * Enter a Data Forward Name that clearly identifies the purpose or destination. * Set permissions like Can View and Can Modify/Delete based on your team’s access needs. * Input the Data Destination * Enter a descriptive name for the Data Forward. * Specify the URL where the data should be sent. * Choose the data type and update frequency. * Add optional key/value header pairs that you want to send along with each HTTP request. * Click Save Destination to apply your changes—this step is required, or all settings will be lost, and then click channels to move to the data selection section * Select the data to be forwarded: * Choose the relevant Modules (devices)—each contains 15 channels (data points). * Choose the relevant Modules (devices)—each contains 15 channels (data points). * Click Save Channels to apply your selections, then proceed to the Permissions section. * Permissions: Configure access rights using the same logic as in the previous step. * Click Done >> to confirm your Data Forward configuration ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Attune** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Attune system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Attune, KODE OS maps them to the following device types: * **Air Quality Sensor** (`airQuality`) | Point | Display Name | | - | - | | `Temperature` | Temperature | | `Humidity` | Humidity | | `Carbon Dioxide` | Carbon Dioxide | | `PM1.0 Mass Concentration` | PM1 0 Mass Concentration | | `PM2.5 Mass Concentration` | PM2 5 Mass Concentration | | `PM4.0 Mass Concentration` | PM4 0 Mass Concentration | | `PM10 Mass Concentration` | PM10 Mass Concentration | | `Equivalent Carbon Dioxide` | Equivalent Carbon Dioxide | | `PM0.5 Number Concentration` | PM0 5 Number Concentration | | `PM1.0 Number Concentration` | PM1 0 Number Concentration | | `PM2.5 Number Concentration` | PM2 5 Number Concentration | | `PM4.0 Number Concentration` | PM4 0 Number Concentration | | `PM10 Number Concentration` | PM10 Number Concentration | | `Typical Particle Size` | Typical Particle Size | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Attune platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Attune platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Attune system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Attune system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Attune API. # Awair Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/awair Connect Awair to KODE OS for indoor environmental quality data > Connect Awair to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Awair to KODE OS. You can discover air quality devices and points, pull snapshot indoor environmental readings over REST, and track sensor history from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Awair](https://kodelabs.com/integration/awair/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites To integrate with the Awair API, ensure you have the following details: * An active account in [https://dashboard.getawair.com](https://dashboard.getawair.com) with the appropriate access permissions. * Valid username and password credentials for the Awair platform. ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Awair developer API usage](https://support.getawair.com/hc/en-us/articles/360049982333-Using-Awair-Developer-APIs) ## Generate API Credentials * Log in to the [https://dashboard.getawair.com/login](https://dashboard.getawair.com/login) using your username and password * On the top-right, open the Dropdown and select Organizations. * Choose the relevant Organization from the list. * In the URL, you’ll find the Organization ID. For example: * [https://dashboard.getawair.com/orgs/11217/metrics](https://dashboard.getawair.com/orgs/11217/metrics) * Organization ID: 11217 * In the left-hand navigation menu, click on API KEY. * Copy the displayed API Key. After completing these steps, you’ll have both the API Token and Organization ID, which will be used in the next step. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Awair** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Protocol** | Yes | dropdown | The communication protocol to use | | **Organization ID** | No | text | Configuration field for Organization ID | | **X-API-Key** | Conditional | password | Configuration field for X-API-Key | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Awair system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Awair, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `plugged` | **True** -- plugged is active / **False** -- plugged is not active | -- | No | Polling | | 2 | `battery` | Device battery level (%) | % | No | Polling | | 3 | `brightness` | Lighting brightness level (%) | % | No | Polling | | 4 | `score` | Composite air quality score (%) | % | No | Polling | | 5 | `temperature` | Current temperature reading (°C) | °C | No | Polling | | 6 | `humidity` | Relative humidity level (%RH) | %RH | No | Polling | | 7 | `co2` | Carbon dioxide (CO₂) concentration (ppm) | ppm | No | Polling | | 8 | `voc` | Volatile organic compound (VOC) level (ppb) | parts\_per\_billion | No | Polling | | 9 | `pm25` | Fine particulate matter (PM2.5) concentration (µg/m³) | micrograms\_per\_cubic\_meter | No | Polling | | 10 | `lux` | Ambient light level (lux) | lux | No | Polling | | 11 | `spl_a` | A-weighted sound pressure level (dB) | decibels | No | Polling | | 12 | `connected` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including plugged, battery, brightness, score, temperature, humidity, co2, voc, and 4 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Awair platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Awair system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Awair API. # Cloudpop Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/cloudpop Connect Cloudpop to KODE OS for indoor environmental quality data > Connect Cloudpop to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Cloudpop to KODE OS. You can discover IEQ devices and points, pull snapshot environmental data over REST, and monitor air quality metrics from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Cloudpop](https://kodelabs.com/integration/cloudpop/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Cloudpop and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Cloudpop** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Project ID** | Yes | password | The project identifier in the external system | | **Email** | Yes | text | The email address associated with the vendor account | | **Key ID** | Yes | password | Configuration field for Key ID | | **Secret** | Yes | password | Configuration field for Secret | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Cloudpop system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Cloudpop, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `battery` | Device battery level (%) | % | No | Polling | | 2 | `temperature` | Current temperature reading (°C) | °C | No | Polling | | 3 | `signal` | Signal strength (%) | % | No | Polling | | 4 | `rssi` | Wireless signal strength (decibelsPerMilliwatt) | decibelsPerMilliwatt | No | Polling | ## What Data You Get ### Point History Time-series readings including battery, temperature, signal, rssi, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Cloudpop platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Cloudpop system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Cloudpop API. # Envelo Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/envelo Connect Envelo to KODE OS for indoor environmental quality data > Connect Envelo to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Envelo to KODE OS. You can discover environmental sensors and points, pull historical IEQ data over REST and webhooks, and keep indoor conditions visible in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Envelo](https://kodelabs.com/integration/envelo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Envelo and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Envelo platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Envelo** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Device Types** | Yes | text | The device types to discover from the external system | | **Envelo Webhook Secret Key** | No | password | The secret key for verifying Envelo webhook payloads | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Envelo system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Envelo, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `instruction` | Instruction code / command value | -- | No | Webhook | | 2 | `Unoccupied` | Unoccupied state indicator | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including instruction, Unoccupied, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Envelo platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Envelo platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Envelo system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Envelo system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Envelo API. # Helvar Lighting System Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/helvar Connect Helvar Lighting System to KODE OS for indoor environmental quality, occupancy, lighting data > Connect Helvar Lighting System to KODE OS for indoor environmental quality, occupancy, lighting data integration ## Overview Use this integration to connect Helvar to KODE OS. You can pull historical lighting, sensor, occupancy, daylight, and air quality data over REST so IEQ and smart lighting context stays unified in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality, Occupancy, Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Helvar Lighting System](https://kodelabs.com/integration/helvar/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Helvar Lighting System and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Helvar Lighting System** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Helvar Lighting System and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Helvar Lighting System, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `energy` | Cumulative energy consumption | -- | No | `differential_energy_accumulator` | Polling | ## What Data You Get ### Point History Time-series readings including energy, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Helvar Lighting System data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `alertId` | -- | | **name** | `alertType` | -- | | **priority** | `priority` | -- | | **status** | `alertStatus` | -- | | **deviceId** | `entityId` | -- | | **deviceName** | `entityName` | -- | | **updatedAt** | `timestamp` | transformed | | **createdAt** | `getCreationTimestamp` | transformed | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) * **Alarm** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Helvar Lighting System platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Helvar Lighting System to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Helvar Lighting System API. # Kaiterra Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/kaiterra Connect Kaiterra to KODE OS for indoor environmental quality data > Connect Kaiterra to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Kaiterra to KODE OS. You can discover air quality devices and points, receive IEQ readings through push collection with snapshot mode, and monitor healthy-building metrics from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Kaiterra](https://kodelabs.com/integration/kaiterra/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * File Validation ## Prerequisites * An active account with Kaiterra and access to their API or developer portal * API key or token from the Kaiterra platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Kaiterra platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kaiterra** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Kaiterra system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Kaiterra, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `rpm10c` | Coarse particulate matter (PM10) concentration (µg/m³) | micrograms\_per\_cubic\_meter | No | `pm10_concentration_detection_sensor` | Polling | | 2 | `rpm25c` | Fine particulate matter (PM2.5) concentration (µg/m³) | micrograms\_per\_cubic\_meter | No | `pm25_concentration_detection_sensor` | Polling | | 3 | `rhumid` | Relative humidity level (%) | % | No | `zone_air_humidity_sensor` | Polling | | 4 | `rtemp` | Current temperature reading (°C) | °C | No | `zone_air_temperature_sensor` | Polling | | 5 | `rco2` | Carbon dioxide (CO₂) concentration (ppm) | ppm | No | `co2_concentration_detection_sensor` | Polling | | 6 | `rtvoc` | Volatile organic compound (VOC) level (ppb) | parts\_per\_billion | No | `voc_concentration_detection_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including rpm10c, rpm25c, rhumid, rtemp, rco2, rtvoc, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Kaiterra platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Kaiterra system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kaiterra API. # Milesight Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/milesight Connect Milesight to KODE OS for indoor environmental quality, occupancy data > Connect Milesight to KODE OS for indoor environmental quality, occupancy data integration ## Overview Use this integration to connect Milesight to KODE OS. You can discover multi-sensor devices and points, pull historical IEQ and occupancy data over REST, and consolidate smart-building sensor streams in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality, Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Milesight](https://kodelabs.com/integration/milesight/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Milesight and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Milesight developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Milesight developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Milesight** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Milesight system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Milesight, KODE OS maps them to the following device types: * **Air Quality Sensor** (`airQuality`) * **Presence / Occupancy Sensor** (`presenceDetection`) * **Traffic Counter** (`trafficCounter`) | Point | Display Name | | - | - | | `Temperature` | Temperature | | `Humidity` | Humidity | | `Pir Status` | Pir Status | | `Als Level` | Als Level | | `CO2` | CO2 | | `Tvoc Level` | Tvoc Level | | `Tvoc` | Tvoc | | `Pressure` | Pressure | | `ConnectStatus` | ConnectStatus | | `Current_Total` | Current Total | | `Current_Staff` | Current Staff | | `Current_Children` | Current Children | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Milesight developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Milesight system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Milesight API. # Milesight Local Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/milesightLocal Connect Milesight Local to KODE OS for indoor environmental quality, leak detection, meters data > Connect Milesight Local to KODE OS for indoor environmental quality, leak detection, meters data integration ## Overview Use this integration to connect Milesight Local to KODE OS. You can discover on-site Milesight devices and points, pull historical IEQ, leak, and metering data over REST, and keep local sensor data available in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality, Leak Detection, Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Milesight Local](https://kodelabs.com/integration/milesight/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Milesight Local and access to their API or developer portal * Username and password credentials for the Milesight Local system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Milesight Local** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Application ID** | Yes | password | The application ID from the vendor's developer portal | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Milesight Local system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `leakage_status` | leakage status | | `gpio` | gpio | | `gpio_type` | gpio type | | `No Leak` | No Leak | | `Leak` | Leak | | `counter/pulse` | counter/pulse | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded * Receive real-time alerts when water leaks or abnormal flow is detected ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Milesight Local system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Milesight Local system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Milesight Local API. # Platformatics Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/platformatics Connect Platformatics to KODE OS for indoor environmental quality, occupancy data > Connect Platformatics to KODE OS for indoor environmental quality, occupancy data integration ## Overview Use this integration to connect Platformatics to KODE OS. You can discover IEQ and occupancy devices and points, pull snapshot environmental data over REST, and simplify how complex building sensor data lands in Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality, Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Platformatics](https://kodelabs.com/integration/platformatics/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Platformatics and access to their API or developer portal * Username and password credentials for the Platformatics system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Platformatics** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Platformatics system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Platformatics, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `humidity` | Relative humidity level (%RH) | %RH | No | Polling | | 2 | `temperature` | Current temperature reading (°F) | °F | No | Polling | | 3 | `occupancy` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | Polling | | 4 | `co2` | Carbon dioxide (CO₂) concentration (ppm) | ppm | No | Polling | ## What Data You Get ### Point History Time-series readings including humidity, temperature, occupancy, co2, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Platformatics system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Platformatics system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Platformatics API. # uHoo Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/uHoo Connect uHoo to KODE OS for indoor environmental quality data > Connect uHoo to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect uHoo to KODE OS. You can discover uHoo devices and points, pull historical indoor air quality and related index readings over REST, and monitor multi-parameter IEQ data from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [uHoo](https://kodelabs.com/integration/uhoo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with uHoo and access to their API or developer portal * API key or token from the uHoo platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the uHoo platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **uHoo** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the uHoo system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from uHoo, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `virusIndex` | Virus risk index (%) | % | No | `satisfaction_percentage_sensor` | Polling | | 2 | `temperature` | Current temperature reading (°C) | °C | No | `zone_air_temperature_sensor` | Polling | | 3 | `humidity` | Relative humidity level (%RH) | %RH | No | `zone_air_humidity_sensor` | Polling | | 4 | `pm1` | Ultrafine particulate matter (PM1) concentration (µg/m³) | microgramsPerCubic | No | `pm1_concentration_detection_sensor` | Polling | | 5 | `pm4` | Coarse particulate matter (PM4) concentration (µg/m³) | microgramsPerCubic | No | `pm4_concentration_detection_sensor` | Polling | | 6 | `pm10` | Coarse particulate matter (PM10) concentration (µg/m³) | microgramsPerCubic | No | `pm10_concentration_detection_sensor` | Polling | | 7 | `pm25` | Fine particulate matter (PM2.5) concentration (µg/m³) | microgramsPerCubic | No | `pm25_concentration_detection_sensor` | Polling | | 8 | `tvoc` | Volatile organic compound (VOC) level (ppb) | parts\_per\_billion | No | `voc_concentration_detection_sensor` | Polling | | 9 | `co` | Carbon monoxide (CO) concentration (ppm) | ppm | No | `co_concentration_detection_sensor` | Polling | | 10 | `co2` | Carbon dioxide (CO₂) concentration (ppm) | ppm | No | `co2_concentration_detection_sensor` | Polling | | 11 | `airPressure` | Atmospheric air pressure (mbar) | millibars | No | `zone_air_static_pressure_sensor` | Polling | | 12 | `ozone` | Ozone (O₃) concentration (ppb) | parts\_per\_billion | No | `o3_concentration_detection_sensor` | Polling | | 13 | `no2` | Nitrogen dioxide (NO₂) concentration (ppb) | parts\_per\_billion | No | `no2_concentration_detection_sensor` | Polling | | 14 | `ch20` | Formaldehyde (HCHO) concentration (ppb) | parts\_per\_billion | No | `hcho_concentration_detection_sensor` | Polling | | 15 | `light` | Ambient light level (lux) | lux | No | `illuminance_sensor` | Polling | | 16 | `sound` | Ambient sound level (dB) | decibels | No | `noise_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including virusIndex, temperature, humidity, pm1, pm4, pm10, pm25, tvoc, and 8 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the uHoo platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the uHoo system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the uHoo API. # Wellstat IAQ Source: https://docs.kodelabs.com/products/integrations/indoor-air-quality/wellstat Connect Wellstat IAQ to KODE OS for indoor environmental quality data > Connect Wellstat IAQ to KODE OS for indoor environmental quality data integration ## Overview Use this integration to connect Wellstat IAQ to KODE OS. You can discover air quality devices and points, pull historical IEQ readings over REST, and track healthy indoor environments for building operations from Data Sources. | Property | Value | | - | - | | **System Type** | Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Wellstat IAQ](https://kodelabs.com/integration/wellstat-iaq/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Wellstat IAQ and access to their API or developer portal * Username and password credentials for the Wellstat IAQ system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Wellstat IAQ** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | Yes | password | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Wellstat IAQ system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Wellstat IAQ, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | **True** -- active / **False** -- inactive | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces * Generate compliance reports for indoor environmental quality standards * Trigger ventilation adjustments when air quality thresholds are exceeded ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Wellstat IAQ system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Wellstat IAQ system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Wellstat IAQ API. # Connected Sensors Source: https://docs.kodelabs.com/products/integrations/leak-detection/connectedSensors Connect Connected Sensors to KODE OS for leak detection data > Connect Connected Sensors to KODE OS for leak detection data integration ## Overview Use this integration to ingest Connected Sensors water and leak telemetry into KODE OS over MQTT. You discover devices and collect historical point data for monitoring usage and leak-related signals. | Property | Value | | - | - | | **System Type** | Leak Detection | | **Communication** | MQTT | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Connected Sensors](https://kodelabs.com/integration/connected-sensors/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * MQTT Data Collection ## Prerequisites * Access to the MQTT broker used by Connected Sensors * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Connected Sensors platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Connected Sensors** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Host** | Conditional | text | The host address for the connection | | **Port** | Conditional | text | The port number for connecting to the system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Connected Sensors system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Connected Sensors, KODE OS maps them to the following device types: * **Leak Detection Sensor** (`leakDetection`) | Point | Display Name | | - | - | | `watermonkeyv3.0single` | watermonkeyv3 0single | | `watermonkeyv3.0` | watermonkeyv3 0 | | `watercounter1.0` | watercounter1 0 | | `ambient_temperature` | ambient temperature | | `maximum_ambient_temperature` | maximum ambient temperature | | `maximum_ambient_temperature_fahrenheit` | maximum ambient temperature fahrenheit | | `maximum_pipe_temperature` | maximum pipe temperature | | `minimum_ambient_temperature` | minimum ambient temperature | | `maximum_pipe_temperature_fahrenheit` | maximum pipe temperature fahrenheit | | `minimum_ambient_temperature_fahrenheit` | minimum ambient temperature fahrenheit | | `ambient_temperature_fahrenheit` | ambient temperature fahrenheit | | `minimum_pipe_temperature` | minimum pipe temperature | | `minimum_pipe_temperature_fahrenheit` | minimum pipe temperature fahrenheit | | `pipe_temperature_rolling_fahrenheit` | pipe temperature rolling fahrenheit | | `barometric_pressure` | barometric pressure | | `ground_floor_pressure` | ground floor pressure | | `middle_floor_pressure` | middle floor pressure | | `humidity` | humidity | | `pipe_temperature` | pipe temperature | | `pipe_temperature_fahrenheit` | pipe temperature fahrenheit | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time alerts when water leaks or abnormal flow is detected * Track leak event history and response times for compliance reporting * Correlate water consumption data with leak detection sensors ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the Connected Sensors devices. Ensure the MQTT client has subscribe permissions. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Connected Sensors system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Connected Sensors API. # Eddy Source: https://docs.kodelabs.com/products/integrations/leak-detection/eddy Connect Eddy to KODE OS for leak detection data > Connect Eddy to KODE OS for leak detection data integration ## Overview Use this integration to connect Eddy leak detection to KODE OS. You discover sensors, pull consumption and leak events, and retain historical trends over REST. | Property | Value | | - | - | | **System Type** | Leak Detection | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Eddy](https://kodelabs.com/integration/eddy/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Eddy and access to their API or developer portal * Username and password credentials for the Eddy system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Eddy** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Eddy system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Eddy, KODE OS maps them to the following device types and data points: ### Leak Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `temperature` | Current temperature reading | -- | No | Polling | | 2 | `relative_humidity` | Relative humidity level | -- | No | Polling | | 3 | `leak_detected` | **True** -- leak detected / **False** -- no leak detected | -- | No | Polling | | 4 | `alert_temperature` | Temperature alert threshold | -- | No | Polling | | 5 | `alert_relative_humidity` | Humidity alert threshold | -- | No | Polling | | 6 | `battery` | Device battery level | -- | No | Polling | | 7 | `signal_strength` | Wireless signal strength | -- | No | Polling | | 8 | `signal_quality` | Wireless signal quality indicator | -- | No | Polling | | 9 | `max_temperature` | Maximum recorded temperature | -- | No | Polling | | 10 | `min_temperature` | Minimum recorded temperature | -- | No | Polling | | 11 | `max_humidity` | Maximum recorded humidity level | -- | No | Polling | | 12 | `min_humidity` | Minimum recorded humidity level | -- | No | Polling | | 13 | `is_minor_leak` | **True** -- minor leak detected / **False** -- no minor leak | -- | No | Polling | | 14 | `is_major_leak` | **True** -- major leak detected / **False** -- no major leak | -- | No | Polling | | 15 | `is_extreme_leak` | **True** -- extreme leak detected / **False** -- no extreme leak | -- | No | Polling | | 16 | `valve_position` | **True** -- valve is open / **False** -- valve is closed | -- | No | Polling | | 17 | `valve_status` | Current valve position status | -- | No | Polling | | 18 | `odometer` | Cumulative flow measurement (odometer reading) | -- | No | Polling | | 19 | `volume` | Total volume measured | -- | No | Polling | | 20 | `pressure_out` | Outlet pressure reading | -- | No | Polling | | 21 | `pressure_in` | Inlet pressure reading | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including temperature, relative\_humidity, leak\_detected, alert\_temperature, alert\_relative\_humidity, battery, signal\_strength, signal\_quality, and 13 more, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique alarm identifier | | **Name** | Alarm name or title | | **Description** | Detailed alarm description | | **Category** | Alarm category (e.g., Building Automation, Security, Fire) | | **Priority** | Alarm priority or severity level | | **Status** | Current alarm state (e.g., Active, Acknowledged, Cleared) | | **Device ID** | ID of the device that generated the alarm | | **Device Name** | Name of the device that generated the alarm | | **Location** | Physical location of the alarm source | | **Updated By** | Person who last updated the alarm | | **Created At** | Timestamp when the alarm was generated | | **Started At** | Timestamp when the alarm condition started | | **Cleared At** | Timestamp when the alarm was cleared or resolved | | **Updated At** | Timestamp of the last alarm state change | ### Polling Schedule * **Point History** -- Default polling: 10 minutes (min: 10 minutes, max: 1 hours) * **Alarm** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time alerts when water leaks or abnormal flow is detected * Track leak event history and response times for compliance reporting * Correlate water consumption data with leak detection sensors ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Eddy system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Eddy system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Eddy API. # Structure Monitoring System Source: https://docs.kodelabs.com/products/integrations/leak-detection/smt Connect Structure Monitoring System to KODE OS for leak detection data > Connect Structure Monitoring System to KODE OS for leak detection data integration ## Overview Use this integration to connect Structure Monitoring System leak detection to KODE OS. You discover assets, collect sensor readings, and ingest related records over REST with historical collection. | Property | Value | | - | - | | **System Type** | Leak Detection | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Structure Monitoring System](https://kodelabs.com/integration/structure-monitoring-system/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Structure Monitoring System and access to their API or developer portal * Username and password credentials for the Structure Monitoring System * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Structure Monitoring System** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Structure Monitoring System and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Structure Monitoring System, KODE OS maps them to the following device types and data points: ### Leak Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Moisture` | Humidity reading (%) | % | No | `soil_humidity_sensor` | Polling | | 2 | `Voltage` | Voltage reading (microVolts) | microVolts | No | -- | Polling | | 3 | `alarm` | **True** -- alarm is active / **False** -- alarm is not active | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including Moisture, Voltage, alarm, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Structure Monitoring System data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | mapped by connector | -- | | **name** | `alarmName` | -- | | **description** | `(formatted)` | -- | | **priority** | `alarmColor` | -- | | **status** | `input` | -- | | **deviceId** | `sensorID` | -- | | **deviceName** | `sensorName` | -- | | **createdAt** | `collectTime` | -- | | **customFields** | mapped by connector | -- | ### Polling Schedule * **Point History** -- Default polling: 425 seconds (min: 425 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time alerts when water leaks or abnormal flow is detected * Track leak event history and response times for compliance reporting * Correlate water consumption data with leak detection sensors ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Structure Monitoring System. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Structure Monitoring System to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Structure Monitoring System API. # Triple Plus Source: https://docs.kodelabs.com/products/integrations/leak-detection/triplePlus Connect Triple Plus to KODE OS for leak detection data > Connect Triple Plus to KODE OS for leak detection data integration ## Overview Use this integration to connect Triple Plus leak detection to KODE OS. You discover sensors and poll snapshot readings for water and leak monitoring across your sites. | Property | Value | | - | - | | **System Type** | Leak Detection | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Triple Plus](https://kodelabs.com/integration/triple-plus/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Triple Plus and access to their API or developer portal * Username and password credentials for the Triple Plus system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Triple Plus** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Triple Plus system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Triple Plus, KODE OS maps them to the following device types and data points: ### Leak Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `battery_level` | Device battery level | -- | No | Polling | | 2 | `rssi` | Wireless signal strength | -- | No | Polling | | 3 | `status` | Current operating status | -- | No | Polling | | 4 | `r_status` | Device reporting status | -- | No | Polling | | 5 | `temperature` | Current temperature reading (°C) | °C | No | Polling | | 6 | `flow` | Current flow rate status | -- | No | Polling | | 7 | `flow_value` | Measured flow rate (mL/min) | millilitresPerMinute | No | Polling | | 8 | `flow_alarm` | Flow alarm status | -- | No | Polling | | 9 | `external_power` | **True** -- external power is connected / **False** -- running on battery | -- | No | Polling | | 10 | `led` | **True** -- LED indicator is on / **False** -- LED indicator is off | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including battery\_level, rssi, status, r\_status, temperature, flow, flow\_value, flow\_alarm, and 2 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time alerts when water leaks or abnormal flow is detected * Track leak event history and response times for compliance reporting * Correlate water consumption data with leak detection sensors ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Triple Plus system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Triple Plus system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Triple Plus API. # Water Intelligence Source: https://docs.kodelabs.com/products/integrations/leak-detection/wint Connect Water Intelligence to KODE OS for leak detection data > Connect Water Intelligence to KODE OS for leak detection data integration ## Overview Use this integration to connect WINT water intelligence to KODE OS. You discover devices, collect leak and consumption signals, and pull historical data for monitoring and trend analysis. | Property | Value | | - | - | | **System Type** | Leak Detection | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Water Intelligence](https://kodelabs.com/integration/water-intelligence/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites * An active account with Water Intelligence and access to their API or developer portal * Username and password credentials for the Water Intelligence system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Water Intelligence** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Water Intelligence system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Water Intelligence, KODE OS maps them to the following device types and data points: ### Leak Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `power_source` | Current power source type | -- | No | Polling | | 2 | `auto_water_shutoff` | Automatic water shutoff status | -- | No | Polling | | 3 | `leak_detection` | Leak detection system status | -- | No | Polling | | 4 | `valve_status` | Current valve position status | -- | No | Polling | | 5 | `leak_exist` | **True** -- leak detected / **False** -- no leak detected | -- | No | Polling | | 6 | `leak_type` | Type of leak detected | -- | No | Polling | | 7 | `leak_level` | Severity level of the detected leak | -- | No | Polling | | 8 | `leak_amount` | Volume of water lost from the leak | -- | No | Polling | | 9 | `leak_duration` | Duration of the detected leak (s) | seconds | No | Polling | | 10 | `leak_flowrate` | Flow rate of the detected leak | -- | No | Polling | | 11 | `last_hour_consumption` | Water consumption in the last hour | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including power\_source, auto\_water\_shutoff, leak\_detection, valve\_status, leak\_exist, leak\_type, leak\_level, leak\_amount, and 3 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time alerts when water leaks or abnormal flow is detected * Track leak event history and response times for compliance reporting * Correlate water consumption data with leak detection sensors ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Water Intelligence system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Water Intelligence system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Water Intelligence API. # Bryte Light Source: https://docs.kodelabs.com/products/integrations/lighting/bryteLight Connect Bryte Light to KODE OS for lighting data > Connect Bryte Light to KODE OS for lighting data integration ## Overview Use this integration to connect Bryte Light to KODE OS. You can discover lighting devices and points, pull snapshot data over REST, and monitor fixture-level readings from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Bryte Light](https://kodelabs.com/integration/brytelight/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Bryte Light and access to their API or developer portal * Username and password credentials for the Bryte Light system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Bryte Light** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Bryte Light system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Bryte Light, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `lighting` | Current lighting output level | -- | No | Polling | | 2 | `airQuality` | Composite air quality index | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including lighting, airQuality, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Bryte Light system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Bryte Light system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Bryte Light API. # Ecco Sensors Source: https://docs.kodelabs.com/products/integrations/lighting/eccoSensors Connect Ecco Sensors to KODE OS for lighting, other data > Connect Ecco Sensors to KODE OS for lighting, other data integration ## Overview Use this integration to connect Ecco Sensors to KODE OS. You can discover devices and points, pull environmental and energy-related data over REST with historical collection, and monitor lighting-adjacent sensor streams alongside other building data. | Property | Value | | - | - | | **System Type** | Lighting, Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Ecco Sensors and access to their API or developer portal * API key or token from the Ecco Sensors platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Ecco Sensors platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Ecco Sensors** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | password | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Ecco Sensors system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Ecco Sensors platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Ecco Sensors system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Ecco Sensors API. # Legrand Encelium Source: https://docs.kodelabs.com/products/integrations/lighting/encelium Connect Legrand Encelium to KODE OS for lighting data > Connect Legrand Encelium to KODE OS for lighting data integration ## Overview Use this integration to connect Legrand Encelium to KODE OS. You can stream lighting data over WebSocket with delta collection, use supported schedules, and keep Encelium points visible in your building Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | WebSocket | | **Collection** | Pull | | **Collection Mode** | DELTA | | **Schedules** | Supported | See [Legrand Encelium](https://kodelabs.com/integration/encelium/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * Discover Schedules * Update Schedules * WebSocket Connection ## Prerequisites * Access credentials for the Legrand Encelium system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Legrand Encelium** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **System ID** | Yes | text | The system identifier in the external platform | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Legrand Encelium system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Legrand Encelium, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `occupancyState` | Current occupancy state of the zone | -- | No | Polling | | 2 | `scene` | Currently active lighting scene | -- | Yes | Polling | | 3 | `savingsReport_calculatedPowerInW` | Calculated lighting power consumption (W) | watts | No | Polling | | 4 | `savingsReport_maximumPowerInW` | Maximum possible power at full brightness (W) | watts | No | Polling | | 5 | `savingsReport_measuredEnergyInWh` | Measured energy consumption (W) | watts | No | Polling | | 6 | `savingsReport_measuredPowerInW` | Measured actual power consumption (W) | watts | No | Polling | | 7 | `savingsReport_savingByLoadSheddingInW` | Energy savings from automatic load shedding (W) | watts | No | Polling | | 8 | `savingsReport_savingByManualControlInW` | Energy savings from manual dimming/switching (W) | watts | No | Polling | | 9 | `savingsReport_savingByTimeScheduleInW` | Energy savings from time-based scheduling (W) | watts | No | Polling | | 10 | `savingsReport_totalSavingsInW` | Total energy savings across all strategies (W) | watts | No | Polling | | 11 | `luxMinimum` | Minimum lux threshold setting | -- | No | Polling | | 12 | `luxMaximum` | Maximum lux threshold setting | -- | No | Polling | | 13 | `controlStatus` | Current control mode of the fixture/zone | -- | Yes | Polling | | 14 | `brightness` | Lighting brightness level | -- | Yes | Polling | | 15 | `colorTemperature` | Current temperature reading | -- | No | Polling | | 16 | `daylight` | Daylight sensor reading | -- | No | Polling | | 17 | `batteryVoltage_mV` | Battery voltage reading | -- | No | Polling | | 18 | `connectionStatus` | Device connectivity status | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including occupancyState, scene, savingsReport\_calculatedPowerInW, savingsReport\_maximumPowerInW, savingsReport\_measuredEnergyInWh, savingsReport\_measuredPowerInW, savingsReport\_savingByLoadSheddingInW, savingsReport\_savingByManualControlInW, and 10 more, collected at regular intervals from connected devices ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Polling Schedule * **Point History** -- Default polling: 60 minutes (min: 60 minutes, max: 60 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Legrand Encelium system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] WebSocket connection failed > > Verify the URL and credentials are correct. Check that the Legrand Encelium system allows WebSocket connections and that network firewalls are not blocking the connection. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Legrand Encelium system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Legrand Encelium API. # Enlighted Source: https://docs.kodelabs.com/products/integrations/lighting/enlighted Connect Enlighted to KODE OS for lighting, occupancy data > Connect Enlighted to KODE OS for lighting, occupancy data integration ## Overview Use this integration to connect Enlighted to KODE OS. You can discover lighting and sensor devices, pull snapshot data over REST for energy and environmental reporting, and align lighting with occupancy context in your portfolio. | Property | Value | | - | - | | **System Type** | Lighting, Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Enlighted](https://kodelabs.com/integration/enlighted/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Enlighted and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Enlighted** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Enlighted system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Enlighted, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `sceneCommand` | Currently active lighting scene | -- | No | `scene_command` | Polling | | 2 | `power` | Current power reading (W) | watts | No | `run_power_sensor` | Polling | | 3 | `temperature` | Current temperature reading (°F) | °F | No | -- | Polling | | 4 | `baseEnergy` | Baseline energy consumption at full brightness (Wh) | wattPerHour | No | -- | Polling | | 5 | `energy` | Cumulative energy consumption (Wh) | wattPerHour | No | `run_energy_accumulator` | Polling | | 6 | `savedEnergy` | Total energy saved through automation (Wh) | wattPerHour | No | -- | Polling | | 7 | `occSavings` | Energy savings from occupancy-based control (Wh) | wattPerHour | No | -- | Polling | | 8 | `ambientSavings` | Energy savings from daylight harvesting (Wh) | wattPerHour | No | -- | Polling | | 9 | `tuneupSavings` | Energy savings from task tuning (Wh) | wattPerHour | No | -- | Polling | | 10 | `manualSavings` | Energy savings from manual control (Wh) | wattPerHour | No | -- | Polling | | 11 | `dimLevel` | Lighting brightness level (%) | % | No | `run_percentage_command` | Polling | | 12 | `occupancy` | **Occupied** -- space is currently in use / **Unoccupied** -- space is available | -- | No | `occupancy_status` | Polling | ## What Data You Get ### Point History Time-series readings including sceneCommand, power, temperature, baseEnergy, energy, savedEnergy, occSavings, ambientSavings, and 4 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Enlighted platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Enlighted system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Enlighted API. # Lighting Control Source: https://docs.kodelabs.com/products/integrations/lighting/lightingControl Connect Lighting Control to KODE OS for lighting data > Connect Lighting Control to KODE OS for lighting data integration ## Overview Use this integration to connect your lighting control system to KODE OS. You can discover devices and points, pull snapshot data over REST, and use supported schedules so lighting state stays synchronized with Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Schedules** | Supported | See [Lighting Control](https://kodelabs.com/integration/lighting-controls/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Discover Schedules * Update Schedules ## Prerequisites * An active account with Lighting Control and access to their API or developer portal * API key or token from the Lighting Control platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Lighting Control platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Lighting Control** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Lighting Control system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Lighting Control, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Occupancy` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Polling | | 2 | `Scene` | Currently active lighting scene | -- | No | `scene_command` | Polling | | 3 | `LuxLevel` | Output level command (%) | % | No | `run_percentage_command` | Polling | | 4 | `CommsFaults` | Number of communication faults detected | -- | No | -- | Polling | | 5 | `LampFaults` | Number of lamp faults detected | -- | No | -- | Polling | | 6 | `EmergencyFaults` | Number of emergency lighting faults detected | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including Occupancy, Scene, LuxLevel, CommsFaults, LampFaults, EmergencyFaults, collected at regular intervals from connected devices ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Lighting Control system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Lighting Control platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Lighting Control system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Lighting Control API. # Lutron Quantum Source: https://docs.kodelabs.com/products/integrations/lighting/lutron Connect Lutron Quantum to KODE OS for lighting data > Connect Lutron Quantum to KODE OS for lighting data integration ## Overview Use this integration to connect Lutron Quantum to KODE OS. You can discover lighting fixtures and points, pull snapshot occupancy and load data over REST, and monitor energy-relevant readings from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Lutron Quantum](https://kodelabs.com/integration/lutron/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Lutron Quantum and access to their API or developer portal * API key or token from the Lutron Quantum platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Lutron Quantum platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Lutron Quantum** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Lutron Quantum system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Lutron Quantum, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Unknown` | **Unknown** / **Unoccupied** / **Occupied** / **AfterHoursInactive** | watts | No | Polling | ## What Data You Get ### Point History Time-series readings including Unknown, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 3 hours (min: 3 hours, max: 3 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Lutron Quantum platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Lutron Quantum system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Lutron Quantum API. # Lutron Athena Source: https://docs.kodelabs.com/products/integrations/lighting/lutronAthena Connect Lutron Athena to KODE OS for lighting data > Connect Lutron Athena to KODE OS for lighting data integration ## Overview Use this integration to connect Lutron Athena to KODE OS. You can discover lighting and shading devices, pull snapshot data over TCP/IP, and monitor fixture and zone state from Data Sources across commercial spaces. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * Network access to the Lutron Athena controller or device * The IP address and port of the on-site system * KODE OS environment with access to Data Sources ## Configure Connector in KODE OS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Lutron Athena** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **IP Address** | Yes | text | The IP address of the on-site controller or device | | **Port** | Yes | text | The port number for connecting to the system | | **Pairing Port** | Yes | text | The port used for device pairing | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Lutron Athena system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in KODE OS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Lutron Athena, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `state` | Current operating state | -- | No | Polling | | 2 | `occupancyStatus` | Current occupancy status of the space | -- | No | Polling | | 3 | `currentScene` | Currently active lighting scene | -- | No | Polling | | 4 | `level` | Current level value | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including state, occupancyStatus, currentScene, level, collected at regular intervals from connected devices. If Lutron has removed a device, point history collection skips that device. Collection continues for the remaining devices, and the connector stays up. ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 5 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the Lutron Athena controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Lutron Athena system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Lutron Athena API. # Lutron Vive Source: https://docs.kodelabs.com/products/integrations/lighting/lutronVive Connect Lutron Vive to KODE OS for lighting data > Connect Lutron Vive to KODE OS for lighting data integration ## Overview Use this integration to connect Lutron Vive to KODE OS. You can discover sensors, remotes, and related devices, pull snapshot lighting data over TCP/IP, and track zone-level state from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Lutron Vive](https://kodelabs.com/integration/lutron-vive/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * Network access to the Lutron Vive controller or device * The IP address and port of the on-site system * Login credentials for the Lutron Vive system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Lutron Vive** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **IP Address** | Yes | text | The IP address of the on-site controller or device | | **Port** | Yes | text | The port number for connecting to the system | | **Pairing Port** | Yes | text | The port used for device pairing | | **Password** | Yes | password | The password for authenticating with the external system | | **Kode Production Certificate** | Yes | password | The production SSL certificate for secure communication | | **Kode Private Key** | Yes | password | The private key for SSL authentication | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Lutron Vive system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Lutron Vive, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `availability` | **Unknown** / **Mixed** / **Available** / **UnAvailable** | -- | No | -- | Polling | | 2 | `failedTransfers_count` | Cumulative count of events | count | No | -- | Polling | | 3 | `batteryStatus_levelState` | Device battery level | -- | No | -- | Polling | | 4 | `occupancyStatus` | Current occupancy status of the space | -- | No | `occupancy_status` | Polling | ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `level` | Current level value | % | No | `run_percentage_sensor` | Polling | | 2 | `instantaneousPower` | Current instantaneous power consumption (W) | watts | No | `run_power_sensor` | Polling | | 3 | `instantaneousMaxPower` | Peak instantaneous power consumption (W) | watts | No | `run_power_sensor` | Polling | | 4 | `switchedLevel` | **Off** / **On** | -- | No | `run_command` | Polling | | 5 | `ccoLevel` | **Closed** / **Open** | -- | No | `run_command` | Polling | | 6 | `receptacleLevel` | **Off** / **On** | -- | No | `run_command` | Polling | ## What Data You Get ### Point History Time-series readings including availability, failedTransfers\_count, batteryStatus\_levelState, occupancyStatus, level, instantaneousPower, instantaneousMaxPower, switchedLevel, and 2 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the Lutron Vive controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Lutron Vive system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Lutron Vive API. # NLight Source: https://docs.kodelabs.com/products/integrations/lighting/nLight Connect NLight to KODE OS for lighting data > Connect NLight to KODE OS for lighting data integration ## Overview Use this integration to connect nLight to KODE OS. You can discover network lighting control devices and points, pull snapshot data over REST, and monitor fixture and zone readings from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [NLight](https://kodelabs.com/integration/nlight/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with NLight and access to their API or developer portal * Username and password credentials for the NLight system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **NLight** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the NLight system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from NLight, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Unoccupied` | **True** -- space is unoccupied / **False** -- space is currently in use | -- | No | `occupancy_status` | Polling | ## What Data You Get ### Point History Time-series readings including Unoccupied, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the NLight system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the NLight system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the NLight API. # Pharos Source: https://docs.kodelabs.com/products/integrations/lighting/pharos Connect Pharos to KODE OS for lighting data > Connect Pharos to KODE OS for lighting data integration ## Overview Use this integration to connect Pharos to KODE OS. You can discover lighting control devices and points, pull snapshot data over REST, and track dynamic and architectural lighting state from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Pharos](https://kodelabs.com/integration/pharos/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Pharos and access to their API or developer portal * Username and password credentials for the Pharos system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Pharos** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Pharos system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Pharos, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | `run_status` | Polling | | 2 | `none` | **none** / **running** / **paused** / **holding\_at\_end** / **released** | -- | Yes | -- | Polling | ## What Data You Get ### Point History Time-series readings including Online, none, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Pharos system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Pharos system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Pharos API. # Prolojik Source: https://docs.kodelabs.com/products/integrations/lighting/prolojik Connect Prolojik to KODE OS for lighting data > Connect Prolojik to KODE OS for lighting data integration ## Overview Use this integration to connect Prolojik to KODE OS. You can ingest lighting data through MQTT push collection with snapshot mode and monitor Prolojik points from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | MQTT | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Prolojik](https://kodelabs.com/integration/prolojik/) on the KODE Labs Integrations Library. ## Supported Capabilities * MQTT Data Collection ## Prerequisites * Access to the MQTT broker used by Prolojik * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Prolojik** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Host** | Yes | text | The host address for the connection | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Path** | Yes | text | The API path or resource path on the external system | ## Devices and Points When you discover devices from Prolojik, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `power` | Current power reading (W) | watts | No | `run_power_sensor` | MQTT | | 2 | `volts` | Voltage reading (V) | V | No | `run_voltage_sensor` | MQTT | | 3 | `runtime` | Total fixture runtime (h) | hours | No | `run_time_accumulator` | MQTT | | 4 | `output_level` | Current output brightness level (%) | % | No | `brightness_percentage_sensor` | MQTT | | 5 | `output_command` | Output level command (%) | % | No | `run_percentage_command` | MQTT | | 6 | `occupancy` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | MQTT | | 7 | `illuminance` | Ambient light level (lux) | lux | No | `illuminance_sensor` | MQTT | | 8 | `lcm_mode_status` | **LCM\_NUL** / **LCM\_NORMAL** / **LCM\_EMERGENCY** / **LCM\_OVERRIDE** / **LCM\_NIGHTMODE** / **LCM\_DIM** / **LCM\_OFF** / **LCM\_EMTEST\_FUNCTIONAL** / **LCM\_LOADSHED** / **LCM\_DEBUG** / **LCM\_CORRIDOR\_ON** / **LCM\_CORRIDOR\_OFF** / **LCM\_EMTEST\_DURATION** / **LCM\_DALI\_ADDRESS** / **LCM\_EVENING** / **LCM\_DALI\_SHORT\_CCT** / **LCM\_SENSORS\_ACTIVE** / **LCM\_CORRIDOR\_SETBACK** / **LCM\_DALI\_RESET** / **LCM\_SENSOR\_INHIBIT** / **LCM\_UNUSED1** / **LCM\_UNUSED2** / **LCM\_SCENE\_01** / **LCM\_SCENE\_02** / **LCM\_SCENE\_03** / **LCM\_SCENE\_04** / **LCM\_SCENE\_05** / **LCM\_SCENE\_06** / **LCM\_SCENE\_07** / **LCM\_SCENE\_08** / **LCM\_LEARN\_ENOCEAN** / **LCM\_FACTORY\_TEST** / **STATUS\_UNKNOWN** | -- | No | `building_status` | MQTT | ## What Data You Get ### Point History Time-series readings including power, volts, runtime, output\_level, output\_command, occupancy, illuminance, lcm\_mode\_status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the Prolojik devices. Ensure the MQTT client has subscribe permissions. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Prolojik API. # SmartCore Source: https://docs.kodelabs.com/products/integrations/lighting/smartCore Connect SmartCore (Vanti) to KODE OS for lighting, occupancy, and door status data > Connect SmartCore to KODE OS for lighting, other data integration ## Overview Use this integration to connect SmartCore to KODE OS. You can discover devices over gRPC, collect lighting, occupancy, and door-status data with hybrid snapshot collection, and surface shared-space and meeting-room conditions in Data Sources. | Property | Value | | - | - | | **System Type** | Lighting, Other | | **Communication** | gRPC (TCP/IP) | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [SmartCore](https://kodelabs.com/integration/smart-core/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Write to Points (lighting levels, transitions) ## Prerequisites * SmartCore (Vanti) gRPC server accessible from the KODE OS network * The IP address and port of the on-site SmartCore controller * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **SmartCore** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Connector Name** | Yes | text | Display name for this connector | | **Host** | Yes | text | gRPC server hostname or IP address | | **Port** | Yes | text | gRPC server port | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the SmartCore system and return a list of available devices and their data points. SmartCore devices are discovered with trait-based point definitions. Each device exposes points based on the traits it supports (e.g., a lighting fixture exposes `LightApi` and `BrightnessSensorApi` traits). Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points SmartCore devices are organized by **traits** -- each trait defines a set of related data points with specific behaviors. All points are collected at **1-minute** intervals. ### BrightnessSensorApi Reports measured ambient brightness for a space. | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `brightness_lux` | Ambient brightness measured by the sensor | lux | No | Polling (1 min) | ### LightApi Controls light output. Brightness is normalized to 0-100%. See device specifications for supported step values. | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `level_percent` | Current device brightness level (0-100%). On write, only one of `level_percent` or preset should be set. Zero value is ignored if a preset is active | % | Yes | Polling (1 min) | | 2 | `brightness_tween.progress` | Read-only transition progress (0-100%) representing how far through the brightness transition the device is | % | No | Polling (1 min) | | 3 | `target_level_percent` | Target brightness level after the current transition completes. Zero values are ignored if a target preset is present | % | No | Polling (1 min) | | 4 | `brightness_tween.total_duration` | Duration of the brightness transition. On write, only the duration value should be provided | seconds | Yes | Polling (1 min) | ### OpenCloseApi For devices that can open and close, such as window contacts, blinds, and garage doors. | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `open_percent` | How open the device is (0 = fully closed, 100 = fully open) | % | No | Polling (1 min) | | 2 | `open_percent_tween_progress` | Transition progress for the open/close operation | % | No | Polling (1 min) | | 3 | `direction` | Movement direction for multi-direction devices. Values: `DIRECTION_UP`, `DIRECTION_DOWN`, `DIRECTION_OPEN`, `DIRECTION_CLOSE`, `DIRECTION_IN`, `DIRECTION_OUT`, and others | -- | No | Polling (1 min) | | 4 | `resistance` | Reports if physical resistance prevents the target position from being achieved (e.g., door held open, window jammed). Values: `RESISTANCE_NOT_OVERRIDDEN`, `RESISTANCE_OVERRIDDEN_EXTERNALLY`, `RESISTANCE_OVERRIDDEN_LOCALLY` | -- | No | Polling (1 min) | | 5 | `target_open_percent` | Target open percentage after the current transition | % | No | Polling (1 min) | | 6 | `open_percent_tween_duration` | Duration of the open/close transition | seconds | No | Polling (1 min) | ### LockUnlockApi For devices that can be locked or unlocked. Position may be in a steady state or transitioning. | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `position` | Current lock state. Values: `LOCKED`, `LOCKING`, `UNLOCKED`, `UNLOCKING` | -- | No | Polling (1 min) | | 2 | `jammed` | Reports whether the lock is jammed and unable to reach the target position | -- | No | Polling (1 min) | ### StatusApi Reports the working status of a device. Reflects the most severe level from any active problems. | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `level` | Device health status, highest severity from current problems. Values: `NOMINAL`, `NOTICE`, `REDUCED_FUNCTION`, `NON_FUNCTIONAL`, `OFFLINE` | -- | No | Polling (1 min) | ## What Data You Get ### Point History Time-series readings including brightness levels, lighting output percentages, door/window open positions, lock states, device health status, and transition progress, collected every 1 minute from connected SmartCore devices. ### Polling Schedule * **Point History** -- Default polling: 1 minute (min: 1 minute, max: 1 hour) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Control and monitor lighting levels across shared spaces and meeting rooms with personalized lux settings * Detect lighting fixture failures automatically and receive maintenance alerts before occupants are affected * Monitor door and window status (open/closed, locked/unlocked) from a central security dashboard * Receive fire door tampering notifications for building safety compliance * Track device health status to proactively schedule maintenance for degraded fixtures ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the host and port are correct. Ensure the SmartCore gRPC server is running and reachable from the KODE OS network. Check that firewalls allow TCP connections on the configured port. > [accordion] Discovery returns no devices > > Verify the SmartCore system has devices registered and that the gRPC server is responding. Run a test connection first to confirm connectivity. Ensure the controller has completed its own device commissioning process. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include network interruptions or the SmartCore controller being restarted. # Trellix Source: https://docs.kodelabs.com/products/integrations/lighting/trellix Connect Trellix to KODE OS for lighting data > Connect Trellix to KODE OS for lighting data integration ## Overview Use this integration to connect Trellix to KODE OS. You can discover WaveLinx-connected lighting devices and points, pull snapshot supervisory data over REST, and monitor portfolio-level lighting state from Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Trellix](https://kodelabs.com/integration/trellix/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Trellix and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Trellix** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Trellix system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Trellix, KODE OS maps them to the following device types and data points: ### Lighting Fixture Canonical Type: `lighting` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `selectedScene` | Currently active lighting scene | -- | No | `scene_command` | Polling | | 2 | `zoneDimmableLight` | Output level command (%) | % | No | `run_percentage_command` | Polling | | 3 | `deviceStatus` | **BAD** / **GOOD** / **UNKNOWN** | -- | No | `fault_label` | Polling | ## What Data You Get ### Point History Time-series readings including selectedScene, zoneDimmableLight, deviceStatus, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Trellix data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **name** | `errorCode` | -- | | **description** | `description` | -- | | **status** | mapped by connector | -- | | **deviceId** | `sourcePublicId` | -- | | **deviceName** | `sourceName` | -- | | **location** | `physicalLocation` | -- | | **createdAt** | `createdTime` | -- | | **updatedAt** | `updatedTime` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) * **Alarm** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Trellix platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Trellix system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Trellix API. # WattStopper Source: https://docs.kodelabs.com/products/integrations/lighting/wattStopper Connect WattStopper to KODE OS for lighting data > Connect WattStopper to KODE OS for lighting data integration ## Overview Use this integration to connect WattStopper to KODE OS. You can discover lighting control devices and points, stream delta updates over TCP/IP, and use supported schedules so code-compliant lighting data stays current in Data Sources. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | DELTA | | **Schedules** | Supported | See [WattStopper](https://kodelabs.com/integration/wattstopper/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Discover Schedules * Create Schedules * Update Schedules * Delete Schedules ## Prerequisites * Network access to the WattStopper controller or device * The IP address and port of the on-site system * Login credentials for the WattStopper system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **WattStopper** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Auth Type** | Yes | dropdown | The authentication method to use | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Protocol** | Yes | dropdown | The communication protocol to use. Options: `http`, `https` | | **IP Address** | Yes | text | The IP address of the on-site controller or device | | **Port** | Yes | text | The port number for connecting to the system | | **Driver Version** | Yes | dropdown | The driver or API version for communication | | **Room** | No | text | The specific room this connector is associated with | | **Model** | Yes | dropdown | The hardware or software model of the system. Options: `Vykon`, `Honeywell`, `FX`, `Distech`, `KMC` | | **Module Version** | No | text | Configuration field for Module Version | | **Niagara Version** | No | text | Configuration field for Niagara Version | | **Module Name** | No | text | Configuration field for Module Name | | **Folder(Leave it blank to discover all devices)** | No | text | Configuration field for Folder(Leave it blank to discover all devices) | | **devicesRootSlot** | No | text | Configuration field for devicesRootSlot | | **Local IP** | No | password | The local network IP address of the on-site system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the WattStopper system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the WattStopper system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Monitor lighting system status, energy usage, and occupancy-driven behavior * Coordinate lighting schedules with HVAC and building automation systems * Track lighting energy consumption and identify optimization opportunities ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the WattStopper controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the WattStopper system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the WattStopper API. # ZenControl Source: https://docs.kodelabs.com/products/integrations/lighting/zencontrol Connect ZenControl to KODE OS for lighting status and live control events > Connect ZenControl to KODE OS for lighting data integration ## Overview Use this integration to connect a ZenControl site to KODE OS. KODE OS discovers gateways, control gear, and application controllers, polls status, and receives live dim, scene, colour, and override events. | Property | Value | | - | - | | **System Type** | Lighting | | **Communication** | REST and WebSocket (Live API) | | **Collection** | Pull and live stream | | **Collection Mode** | SNAPSHOT | ## Supported capabilities * Discover devices and points * Collect sensor data * Receive WebSocket (live) data * Write dim level, scene, colour temperature, and override ## Prerequisites * A ZenControl cloud account with API access * The API URL, authorization URL, client ID, client secret, and user code * The Live API enabled for the site * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `ZenControl`. 3. Select `+ Add Datasource`. 4. Complete the connector fields, then validate credentials so KODE OS can load sites. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | ZenControl API base URL | | **Auth URL** | Yes | text | URL used to request and refresh the access token | | **Client ID** | Yes | text | OAuth client identifier | | **Client Secret** | Yes | password | OAuth client secret | | **User Code** | Yes | password | One-time user code for the first token | | **Site ID** | Yes | dropdown or text | Site to collect. Options load after credentials validate. The field is a text box when no sites are returned. | | **Notes** | No | text | Additional connection details | `Site ID` shows the site name and stores the site identifier. KODE OS reuses a valid token and refreshes it before it expires. ## Discover devices and points After you save the connector, select `Discover`. Review the returned devices and points, then save the records you want in KODE OS. Every device uses the `lighting` canonical type. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and points ### Gateway A gateway is not polled. Its points arrive on the Live API gateway connection stream. | Point | Description | Unit | Writable | Ontology field | Collection | | - | - | - | - | - | - | | `isConnected` | Whether the gateway is connected. Values are `Inactive` and `Active`. | -- | No | `connection_status` | `event.gateway.connection-status` | | `lastConnected` | Last connected time in the building time zone | -- | No | -- | `event.gateway.connection-status` | | `lastCommunicated` | Last communicated time in the building time zone | -- | No | -- | `event.gateway.connection-status` | ### ECG (control gear) `status` is polled. The other points arrive as live events. `arcLevel`, `scene`, and `override` are writable. `colourTemp` is writable only when the gear supports colour control. | Point | Description | Unit | Writable | Ontology field | Collection | | - | - | - | - | - | - | | `status` | Online or offline state. Values are `Inactive` and `Active`. | -- | No | `connection_status` | REST poll | | `arcLevel` | Dim level as a percent, from 0 to 100 | % | Yes | `run_percentage_command` | `event.ecg.arc-level` | | `scene` | Last-heard scene, from 0 to 15 | -- | Yes | `scene_command` | `event.ecg.scene-change` | | `colourTemp` | Colour temperature number from the Live API | -- | Conditional | -- | `event.ecg.colour-temp` | | `override` | Active override labels, or `None` | -- | Yes | -- | `event.ecg.override-change` | ### ECD (application controller) Both points use a REST poll. A missing operating mode is collected as down. | Point | Description | Unit | Writable | Ontology field | Collection | | - | - | - | - | - | - | | `status` | Online or offline state. Values are `Inactive` and `Active`. | -- | No | `connection_status` | REST poll | | `operatingMode` | Numeric operating mode | -- | No | `device_mode` | REST poll | ## What data you get ### Point history REST polls refresh `status` and `operatingMode`. Live events refresh dim level, scene, colour temperature, override, and gateway connection. KODE OS stores `arcLevel` as a percent. A write converts that percent to a DALI arc level from 0 to 254. ### Polling schedule * **Point history** — Default polling: 15 minutes (min: 15 minutes, max: 1 hour) Live WebSocket events do not use that poll interval. For more details, see the [Data collection guide](/products/integrations/capabilities/data-collection). ## Available actions Write actions are available on the writable ECG points. | Point | Field | Required | Input | Options / default | | - | - | - | - | - | | `arcLevel` | `Level (%)` | Yes | Number | Current value. Range 0 to 100. | | `scene` | `Scene` | Yes | Drop down | `Scene 0` through `Scene 15` | | `colourTemp` | `Colour temperature` | Yes | Number | Kelvin. KODE OS converts the value before sending it. | | `override` | `Override` | Yes | Drop down | Lux, PIR, Colour, Intensity, Switch, Inhibit without switch, Inhibit with switch | | `override` | `Duration` | Yes | Duration | Includes a permanent duration | `colourTemp` can be written only on gear discovered as colour control. Other gear does not accept the command. ## Use cases Once connected, you can: * See dim level and the latest scene on each control gear * Check gateway and device connection status * Set a scene, dim level, colour temperature, or timed override from KODE OS ## Troubleshooting > [accordion] Authentication or connection error > > Confirm the API URL, Auth URL, client ID, and client secret. A used, expired, or mismatched user code must be replaced before the first token can be issued. > [accordion] No live events arriving > > Confirm that the Live API is enabled for the site and that the connector is up. Dim level, scene, colour temperature, and override arrive only over the WebSocket. > [accordion] Discovery returns no devices > > Confirm that the credentials can list the selected site. Run `Discover` again after the connection test succeeds. > [accordion] Colour temperature write is rejected > > Only colour-control gear has a writable `colourTemp` point. Enter the value in Kelvin. # Accuenergy Source: https://docs.kodelabs.com/products/integrations/meters/accuenergy Connect Accuenergy to KODE OS for meters data > Connect Accuenergy to KODE OS for meters data integration ## Overview Use this integration to connect your Accuenergy power meters, submeters, and communication devices to KODE OS over MQTT. You can discover devices and points, then pull snapshot sensor readings on a schedule so consumption and status stay current in your building model. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | MQTT | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Accuenergy](https://kodelabs.com/integration/accuenergy/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * MQTT Data Collection * File Validation ## Prerequisites * Access to the MQTT broker used by Accuenergy * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Accuenergy** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Host** | Yes | text | The host address for the connection | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Path** | Yes | text | The API path or resource path on the external system | | **Version** | Yes | dropdown | The API or firmware version to use | | **Device ID** | Yes | text | The device identifier in the external system | | **Device Name** | Yes | text | The display name of the device in the external system | | **File** | Conditional | text | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Accuenergy system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Accuenergy, KODE OS maps them to the following device types: * **Electric Meter** (`electricMeter`) ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the Accuenergy devices. Ensure the MQTT client has subscribe permissions. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Accuenergy system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Accuenergy API. # APEX API Source: https://docs.kodelabs.com/products/integrations/meters/apex Connect APEX API to KODE OS for meters data > Connect APEX API to KODE OS for meters data integration ## Overview Use this integration to connect your APEX multi-protocol edge gateway to KODE OS. You can discover meters from your uploaded device file, then combine scheduled polling with webhooks so status and related readings land in KODE OS without manual exports. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with APEX API and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the APEX API platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **APEX API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the APEX API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from APEX API, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | Numeric status code | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the APEX platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the APEX platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the APEX system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the APEX system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the APEX API. # Carma Source: https://docs.kodelabs.com/products/integrations/meters/carma Connect Carma to KODE OS for meters data > Connect Carma to KODE OS for meters data integration ## Overview Use this integration to connect your Carma submetering account to KODE OS. You can discover water meters and their points, then pull historical readings for consumption, daily use, and registered reads so billing-aligned utility data appears alongside the rest of your portfolio. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Carma](https://kodelabs.com/integration/carmacorp/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites To integrate with the Carma API, ensure you have the following details: * An active account in [https://carmaplus.ca](https://carmaplus.ca) with the appropriate access permissions. * Valid username and password credentials for the Atlas platform. Password\* API Building ID\* Generated in Step 2 Fields marked with an asterisk \* are mandatory for completing the integration. ## Generate API Credentials * Log in to the [https://carmaplus.ca/app](https://carmaplus.ca/app) using your username and password * Choose your building * In the URL, you’ll find the Building ID. For example: * [https://carmaplus.ca/app/GraphIt/GraphIt2.aspx?buildingID=818](https://carmaplus.ca/app/GraphIt/GraphIt2.aspx?buildingID=818) * Building ID: 818 After completing the steps above, your Building ID will be used in the next step. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Carma** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Carma system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Carma, KODE OS maps them to the following device types and data points: ### Water Meter Canonical Type: `waterMeter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Connection Status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | `connection_status` | Polling | | 2 | `Current Value` | Current meter reading | -- | No | -- | Polling | | 3 | `Calculated Current Value` | Calculated current consumption value | -- | No | -- | Polling | | 4 | `Registered Reading` | Registered meter reading | -- | No | -- | Polling | | 5 | `Daily Consumption` | Daily water consumption | -- | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including Connection Status, Current Value, Calculated Current Value, Registered Reading, Daily Consumption, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Carma platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Carma system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Carma API. # Datto Source: https://docs.kodelabs.com/products/integrations/meters/datto Connect Datto to KODE OS for meters data > Connect Datto to KODE OS for meters data integration ## Overview Use this integration to bring Datto-managed switches, access points, and related network nodes into KODE OS as meter-style assets. You can discover devices and collect snapshot polled points—such as client counts, port activity, and connection status—for operational visibility next to your other building data. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Datto](https://kodelabs.com/integration/datto/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Datto and access to their API or developer portal * API key or token from the Datto platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Datto platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Datto** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Secret Key** | Yes | password | The secret key for API authentication | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Datto system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Datto, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Active Clients` | Number of currently connected clients | -- | No | Polling | | 2 | `Down` | **True** -- Down is active / **False** -- Down is not active | -- | No | Polling | | 3 | `Connection Status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | | 4 | `Node Count` | Cumulative count of events | -- | No | Polling | | 5 | `Enable` | **True** -- Enable is active / **False** -- Enable is not active | -- | No | Polling | | 6 | `Monitor Mode` | **True** -- Monitor Mode is active / **False** -- Monitor Mode is not active | -- | No | Polling | | 7 | `Total Ports` | Total number of network ports | -- | No | Polling | | 8 | `Active Ports` | Number of currently active network ports | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Active Clients, Down, Connection Status, Node Count, Enable, Monitor Mode, Total Ports, Active Ports, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Datto platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Datto system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Datto API. # Elvaco Source: https://docs.kodelabs.com/products/integrations/meters/elvaco Connect Elvaco to KODE OS for meters data > Connect Elvaco to KODE OS for meters data integration ## Overview Use this integration to connect your Elvaco utility metering platform to KODE OS. You can discover meters and points over REST, then pull snapshot readings (for example device status) on a schedule for water, gas, and electrical assets in one place. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Elvaco](https://kodelabs.com/integration/elvaco/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Elvaco and access to their API or developer portal * Username and password credentials for the Elvaco system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Elvaco** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Elvaco system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Elvaco, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `status` | Current operating status | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Elvaco system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Elvaco system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Elvaco API. # Enertiv Source: https://docs.kodelabs.com/products/integrations/meters/enertiv Connect Enertiv to KODE OS for meters data > Connect Enertiv to KODE OS for meters data integration ## Overview Use this integration to connect Enertiv to KODE OS. You can discover meters, pull scheduled point history (for example power usage), ingest non-sensor records, and collect meter-bill data so operations, submetering, and finance views share the same source of truth. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Enertiv](https://kodelabs.com/integration/enertiv/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Enertiv and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Enertiv** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Enertiv system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Enertiv, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `power_usage` | Current power consumption (kW) | kW | No | Polling | ## What Data You Get ### Point History Time-series readings including power\_usage, collected at regular intervals from connected devices ### Meter Bills Utility meter billing data including consumption, rates, and billing period details ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) * **MeterBill** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Enertiv platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Enertiv system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Enertiv API. # Fludia Source: https://docs.kodelabs.com/products/integrations/meters/fludia Connect Fludia to KODE OS for meters data > Connect Fludia to KODE OS for meters data integration ## Overview Use this integration to connect Fludia wireless metering endpoints to KODE OS. You can discover meters and collect historical point data—such as signal quality, activity, and low-battery indicators—on your configured polling interval. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Fludia](https://kodelabs.com/integration/fludia/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Fludia and access to their API or developer portal * Username and password credentials for the Fludia system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Fludia** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Fludia system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Fludia, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `snr` | Signal-to-noise ratio | -- | No | Polling | | 2 | `rssi` | Wireless signal strength | -- | No | Polling | | 3 | `active` | **True** -- device is active / **False** -- device is inactive | -- | No | Polling | | 4 | `low_battery` | **True** -- battery level is low, replacement needed / **False** -- battery level is adequate | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including snr, rssi, active, low\_battery, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Fludia system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Fludia system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Fludia API. # Walchem Fluent Source: https://docs.kodelabs.com/products/integrations/meters/fluent Connect Walchem Fluent to KODE OS for meters data > Connect Walchem Fluent to KODE OS for meters data integration ## Overview Use this integration to connect Walchem Fluent cloud controllers to KODE OS. You can discover treatment assets and collect snapshot sensor readings plus alarm streams—for example flow-related points—so water-treatment performance appears next to your other facility telemetry. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Walchem Fluent](https://kodelabs.com/integration/walchem-fluent/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Walchem Fluent and access to their API or developer portal * API key or token from the Walchem Fluent platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Walchem Fluent platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Walchem Fluent** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Walchem Fluent system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `RELAY_FLOW_TIMER` | Relay Flow Timer | | `Flow` | Flow | | `No Flow` | No Flow | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique alarm identifier | | **Name** | Alarm name or title | | **Description** | Detailed alarm description | | **Category** | Alarm category (e.g., Building Automation, Security, Fire) | | **Priority** | Alarm priority or severity level | | **Status** | Current alarm state (e.g., Active, Acknowledged, Cleared) | | **Device ID** | ID of the device that generated the alarm | | **Device Name** | Name of the device that generated the alarm | | **Location** | Physical location of the alarm source | | **Updated By** | Person who last updated the alarm | | **Created At** | Timestamp when the alarm was generated | | **Started At** | Timestamp when the alarm condition started | | **Cleared At** | Timestamp when the alarm was cleared or resolved | | **Updated At** | Timestamp of the last alarm state change | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **Alarm** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Walchem Fluent platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Walchem Fluent system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Walchem Fluent API. # Gema Source: https://docs.kodelabs.com/products/integrations/meters/gema Connect Gema to KODE OS for meters data > Connect Gema to KODE OS for meters data integration ## Overview Use this integration to connect Gema to KODE OS. You can discover energy meters using your required device file, register the assets you need, and pull scheduled point history for portfolio-level consumption monitoring. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * File Validation ## Prerequisites * An active account with Gema and access to their API or developer portal * Username and password credentials for the Gema system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Gema** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Gema system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Gema, KODE OS maps them to the following device types: * **Energy Meter** (`energyMeter`) ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Gema system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Gema system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Gema API. # Greenworld Solutions Source: https://docs.kodelabs.com/products/integrations/meters/greenworldSolutions Connect Greenworld Solutions to KODE OS for meters data > Connect Greenworld Solutions to KODE OS for meters data integration ## Overview Use this integration to connect Greenworld Solutions metering to KODE OS. You can discover meters and points, then pull historical energy measurements on a schedule for monitoring, benchmarking, and optimization workflows. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Greenworld Solutions](https://kodelabs.com/integration/green-world-solutions/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Greenworld Solutions and access to their API or developer portal * API key or token from the Greenworld Solutions platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Greenworld Solutions platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Greenworld Solutions** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Greenworld Solutions system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Greenworld Solutions, KODE OS maps them to the following device types and data points: ### Electric Meter Canonical Type: `electricMeter` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `reading` | Current meter reading | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including reading, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 3 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Greenworld Solutions platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Greenworld Solutions system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Greenworld Solutions API. # Inverter Source: https://docs.kodelabs.com/products/integrations/meters/inverter Connect Inverter to KODE OS for meters data > Connect Inverter to KODE OS for meters data integration ## Overview Use this integration to bring inverter telemetry into KODE OS. You can discover inverter devices and points, receive pushed readings via webhook for near-real-time visibility, and use pull-based collection where the connector exposes it for reporting and analysis. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | HISTORICAL | See [Inverter](https://kodelabs.com/integration/inverter-api/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with Inverter and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Inverter platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Inverter** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Version** | Yes | dropdown | The API or firmware version to use | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Inverter system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Inverter, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `status` | **Connected** -- device is communicating normally / **Disconnected** -- device is not reachable | -- | No | Webhook | | 2 | `Grid Voltage L1` | Grid voltage on phase L1 (V) | V | No | Webhook | | 3 | `Grid Voltage L2` | Grid voltage on phase L2 (V) | V | No | Webhook | | 4 | `Grid Voltage L3` | Grid voltage on phase L3 (V) | V | No | Webhook | | 5 | `Grid Current L1` | Grid current on phase L1 (A) | A | No | Webhook | | 6 | `Grid Current L2` | Grid current on phase L2 (A) | A | No | Webhook | | 7 | `Grid Current L3` | Grid current on phase L3 (A) | A | No | Webhook | | 8 | `Grid Power L1` | Grid power on phase L1 (kW) | kW | No | Webhook | | 9 | `Grid Power L2` | Grid power on phase L2 (kW) | kW | No | Webhook | | 10 | `Grid Power L3` | Grid power on phase L3 (kW) | kW | No | Webhook | | 11 | `Total Grid Power` | Total grid power across all phases (kW) | kW | No | Webhook | | 12 | `Grid Frequency` | AC grid frequency (Hz) | hertz | No | Webhook | | 13 | `Internal CT L1 Power` | Internal CT power measurement on phase L1 (kW) | kW | No | Webhook | | 14 | `Internal CT L2 Power` | Internal CT power measurement on phase L2 (kW) | kW | No | Webhook | | 15 | `Internal CT L3 Power` | Internal CT power measurement on phase L3 (kW) | kW | No | Webhook | | 16 | `Load Voltage L1` | Load voltage on phase L1 (V) | V | No | Webhook | | 17 | `Load Voltage L2` | Load voltage on phase L2 (V) | V | No | Webhook | | 18 | `Load Voltage L3` | Load voltage on phase L3 (V) | V | No | Webhook | | 19 | `Load Current L1` | Load current on phase L1 (A) | A | No | Webhook | | 20 | `Load Current L2` | Load current on phase L2 (A) | A | No | Webhook | | 21 | `Load Current L3` | Load current on phase L3 (A) | A | No | Webhook | | 22 | `Load L1 Power` | Load power on phase L1 (kW) | kW | No | Webhook | | 23 | `Load L2 Power` | Load power on phase L2 (kW) | kW | No | Webhook | | 24 | `Load L3 Power` | Load power on phase L3 (kW) | kW | No | Webhook | | 25 | `Inverter L1 Power` | Inverter output power on phase L1 (kW) | kW | No | Webhook | | 26 | `Inverter L2 Power` | Inverter output power on phase L2 (kW) | kW | No | Webhook | | 27 | `Inverter L3 Power` | Inverter output power on phase L3 (kW) | kW | No | Webhook | | 28 | `Total Load Power` | Total load power consumption across all phases (kW) | kW | No | Webhook | | 29 | `Total Battery Charge` | Total energy charged into battery (kWh) | kWh | No | Webhook | | 30 | `Total Battery Discharge` | Total energy charged into battery (kWh) | kWh | No | Webhook | | 31 | `Total Energy Bought` | Total energy imported from the grid (kWh) | kWh | No | Webhook | | 32 | `Total Load Consumption` | Total energy consumed by connected loads (kWh) | kWh | No | Webhook | | 33 | `Battery Temperature` | Battery temperature (°C) | °C | No | Webhook | | 34 | `Battery Voltage` | Battery voltage reading (V) | V | No | Webhook | | 35 | `Battery SOC` | Battery state of charge (%) | % | No | Webhook | | 36 | `Battery Power 1` | Battery power draw or output (kW) | kW | No | Webhook | | 37 | `Battery Power 2` | Battery power draw or output (kW) | kW | No | Webhook | | 38 | `Total Battery Power` | Total battery power (kW) | kW | No | Webhook | | 39 | `Battery Current 1` | Battery current flow (A) | A | No | Webhook | | 40 | `Battery Current 2` | Battery current flow (A) | A | No | Webhook | | 41 | `Total Battery Current` | Total battery current flow (A) | A | No | Webhook | | 42 | `Serial Number` | Device serial number identifier | -- | No | Webhook | | 43 | `Modem Serial Number` | Device serial number identifier | -- | No | Webhook | | 44 | `Grid Voltage` | Grid voltage (V) | V | No | Webhook | | 45 | `Grid Current` | Grid current (A) | A | No | Webhook | | 46 | `Grid Power` | Grid power (kW) | kW | No | Webhook | | 47 | `Inv Temp` | Current temperature reading (°C) | °C | No | Webhook | | 48 | `Env Temp` | Current temperature reading (°C) | °C | No | Webhook | | 49 | `Load Voltage` | Load voltage (V) | V | No | Webhook | | 50 | `Load Current` | Load current (A) | A | No | Webhook | | 51 | `Load Power` | Load power (kW) | kW | No | Webhook | | 52 | `Bat Voltage` | Battery voltage (V) | V | No | Webhook | | 53 | `Bat Current` | Battery current (A) | A | No | Webhook | | 54 | `Bat Power` | Battery power (kW) | kW | No | Webhook | | 55 | `Bat Temp` | Current temperature reading (°C) | °C | No | Webhook | | 56 | `Bat Soc` | Battery state of charge (%) | % | No | Webhook | | 57 | `SN` | Device serial number | -- | No | Webhook | | 58 | `Door Contact` | **True** -- Door Contact is active / **False** -- Door Contact is not active | -- | No | Webhook | | 59 | `Router Serial Number` | Device serial number identifier | -- | No | Webhook | | 60 | `Battery Charge Energy` | Total energy charged into battery (kWh) | kWh | No | Webhook | | 61 | `Battery Discharge Energy_1` | Total energy discharged from battery (kWh) | kWh | No | Webhook | | 62 | `Battery Discharge Energy` | Total energy discharged from battery (kWh) | kWh | No | Webhook | ## What Data You Get ### Point History Time-series readings including status, Grid Voltage L1, Grid Voltage L2, Grid Voltage L3, Grid Current L1, Grid Current L2, Grid Current L3, Grid Power L1, and 54 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 5 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Inverter platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Inverter platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Inverter system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Inverter system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Inverter API. # Kocos Source: https://docs.kodelabs.com/products/integrations/meters/kocos Connect Kocos to KODE OS for meters data > Connect Kocos to KODE OS for meters data integration ## Overview Use this integration to connect Kocos metering to KODE OS. You can discover meters and data points, poll sensor and non-sensor values on a schedule, and subscribe to webhooks so updates arrive without waiting for the next poll. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Kocos](https://kodelabs.com/integration/kocos/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with Kocos and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Kocos platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kocos** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Kocos system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Kocos, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `connection_status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including connection\_status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Kocos platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Kocos platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Kocos system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Kocos system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kocos API. # IES MACH Source: https://docs.kodelabs.com/products/integrations/meters/mach Connect IES MACH to KODE OS for meters data > Connect IES MACH to KODE OS for meters data integration ## Overview Use this integration to connect IES MACH to KODE OS. You can discover meter-class assets, collect sensor and non-sensor readings on a schedule, and ingest historical intervals so you can analyze each asset’s energy footprint alongside the rest of your portfolio. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [IES MACH](https://kodelabs.com/integration/iesmach/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with IES MACH and access to their API or developer portal * Username and password credentials for the IES MACH system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **IES MACH** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the IES MACH system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from IES MACH, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `occupancy` | Current occupancy count | -- | No | Polling | | 2 | `cycle` | Number of operating cycles completed | -- | No | Polling | | 3 | `averagePower` | Average power consumption | -- | No | Polling | | 4 | `consumption` | Current energy consumption | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including occupancy, cycle, averagePower, consumption, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 15 minutes) * **DeviceMetric** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the IES MACH system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the IES MACH system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the IES MACH API. # MeterConnex Source: https://docs.kodelabs.com/products/integrations/meters/meterConnex Connect MeterConnex to KODE OS for meters data > Connect MeterConnex to KODE OS for meters data integration ## Overview Use this integration to connect MeterConnex meter data management to KODE OS. You can discover meters, poll snapshot readings on a schedule, and register webhooks so interrogation results and events surface in KODE OS without separate portals. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [MeterConnex](https://kodelabs.com/integration/meterconnex/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with MeterConnex and access to their API or developer portal * Username and password credentials for the MeterConnex system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the MeterConnex platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **MeterConnex** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the MeterConnex system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from MeterConnex, KODE OS maps them to the following device types: * **Electric Meter** (`electricMeter`) * **Water Meter** (`waterMeter`) * **Gas Meter** (`gasMeter`) * **Steam Meter** (`steamMeter`) * **Energy Meter** (`energyMeter`) | Point | Display Name | | - | - | | `value` | value | | `calculatedIntervalValue` | calculatedIntervalValue | | `cumulativeValue` | cumulativeValue | | `powerFactor` | powerFactor | | `Heating` | Heating | | `Cooling` | Cooling | | `Water` | Water | | `Gas` | Gas | | `Hot Water` | Hot Water | | `Cold Water` | Cold Water | | `Chilled Water` | Chilled Water | | `Steam` | Steam | | `pf` | pf | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the MeterConnex system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the MeterConnex platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the MeterConnex system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the MeterConnex system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the MeterConnex API. # NuEnergen Source: https://docs.kodelabs.com/products/integrations/meters/nuEnergen Connect NuEnergen to KODE OS for meters data > Connect NuEnergen to KODE OS for meters data integration ## Overview Use this integration to connect NuEnergen to KODE OS. You can discover meters and points, then pull current and historical consumption data on a schedule for trending, reporting, and anomaly review. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [NuEnergen](https://kodelabs.com/integration/nuenergen/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites * An active account with NuEnergen and access to their API or developer portal * API key or token from the NuEnergen platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the NuEnergen platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **NuEnergen** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Token** | Yes | password | The API token for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the NuEnergen system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from NuEnergen, KODE OS maps them to the following device types and data points: ### Electric Meter Canonical Type: `electricMeter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `quantity` | Metered quantity reading | -- | No | -- | Polling | | 2 | `calculatedQuantity` | Calculated consumption quantity (kWh) | kilowattPerHour | No | `differential_electric_energy_accumulator` | Polling | ## What Data You Get ### Point History Time-series readings including quantity, calculatedQuantity, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the NuEnergen platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the NuEnergen system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the NuEnergen API. # Pagi Source: https://docs.kodelabs.com/products/integrations/meters/pagi Connect Pagi to KODE OS for meters data > Connect Pagi to KODE OS for meters data integration ## Overview Use this integration to connect the PAGI-e metering API to KODE OS. You can discover electricity, water, and gas meters, then pull historical usage on a schedule so Canadian utility consumption is visible next to your other meter feeds. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Pagi](https://kodelabs.com/integration/pagi/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Pagi and access to their API or developer portal * API key or token from the Pagi platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Pagi platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Pagi** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Pagi system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Pagi, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `consumption` | Current energy consumption | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including consumption, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Pagi platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Pagi system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Pagi API. # PME Source: https://docs.kodelabs.com/products/integrations/meters/pme Connect PME to KODE OS for meters data > Connect PME to KODE OS for meters data integration ## Overview Use this integration to connect Schneider Electric Power Monitoring Expert (PME) to KODE OS over TCP/IP. You can ingest sensor data from your PME deployment so critical-facility electrical monitoring, historical intervals, and power-quality context are available in the same model as your other integrations. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Collect Sensor Data ## Prerequisites * Network access to the PME controller or device * The IP address and port of the on-site system * Login credentials for the PME system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **PME** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Auth Type** | Yes | dropdown | The authentication method to use | | **IP Address** | Yes | text | The IP address of the on-site controller or device | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Conditional | text | The password for authenticating with the external system | | **Read Path** | Yes | text | The path for reading data from the external system | | **Meter Organization** | Yes | text | The organization identifier for the meter in the external system | | **Meter Location** | Yes | text | The location identifier for the meter in the external system | ## Devices and Points When you discover devices from PME, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `connection_status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including connection\_status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the PME controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the PME API. # Redaptive Source: https://docs.kodelabs.com/products/integrations/meters/redaptive Connect Redaptive to KODE OS for meters data > Connect Redaptive to KODE OS for meters data integration ## Overview Use this integration to connect Redaptive Power Meter data to KODE OS. You can discover circuits and meters exposed by the API, then pull historical energy readings for high-accuracy load tracking inside your building management workflows. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Redaptive](https://kodelabs.com/integration/redaptive/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Redaptive and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Redaptive developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Redaptive developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Redaptive** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Redaptive system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Redaptive, KODE OS maps them to the following device types: * **Electric Meter** (`electricMeter`) | Point | Display Name | | - | - | | `power` | power | | `rmsApparentPower` | rmsApparentPower | | `rmsCurrent` | rmsCurrent | | `rmsVoltage` | rmsVoltage | | `activePower` | activePower | | `reactivePower` | reactivePower | | `apparentPower` | apparentPower | | `fundamentalPower` | fundamentalPower | | `powerFactor` | powerFactor | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Redaptive developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Redaptive system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Redaptive API. # Sapient Source: https://docs.kodelabs.com/products/integrations/meters/sapient Connect Sapient to KODE OS for meters, lighting data > Connect Sapient to KODE OS for meters, lighting data integration ## Overview Use this integration to connect Sapient to KODE OS. You can discover meters and lighting-related assets, collect electricity usage on a schedule, and ingest non-sensor records so efficiency and performance data sits beside the rest of your building telemetry. | Property | Value | | - | - | | **System Type** | Meters, Lighting | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Sapient and access to their API or developer portal * Username and password credentials for the Sapient system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Sapient** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Email** | Yes | text | The email address associated with the vendor account | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Sapient system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Sapient, KODE OS maps them to the following device types and data points: ### Electric Meter Canonical Type: `electricMeter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `energy` | Cumulative energy consumption (kWh) | kilowattPerHour | No | `differential_electric_energy_accumulator` | Polling | | 2 | `power` | Current power reading (W) | watts | No | `average_power_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including energy, power, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio * Monitor lighting system status, energy usage, and occupancy-driven behavior ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Sapient system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Sapient system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Sapient API. # SHM Aphex Meter Online Source: https://docs.kodelabs.com/products/integrations/meters/shmAphex Connect SHM Aphex Meter Online to KODE OS for meters data > Connect SHM Aphex Meter Online to KODE OS for meters data integration ## Overview Use this integration to connect SHM Aphex Meter Online to KODE OS. You can complete file-assisted discovery, register the meters you need, and pull historical point data on the connector’s polling schedule for ongoing metering visibility. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [SHM Aphex Meter Online](https://kodelabs.com/integration/shm-aphex-meter-online/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * File Validation ## Prerequisites * An active account with SHM Aphex Meter Online and access to their API or developer portal * Username and password credentials for the SHM Aphex Meter Online system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **SHM Aphex Meter Online** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the SHM Aphex Meter Online system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the SHM Aphex Meter Online system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the SHM Aphex Meter Online system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the SHM Aphex Meter Online API. # SkySpark Source: https://docs.kodelabs.com/products/integrations/meters/skySpark Connect SkySpark to KODE OS for meters data > Connect SkySpark to KODE OS for meters data integration ## Overview Use this integration to connect SkySpark to KODE OS. You can discover meter-related assets in SkySpark, then receive pushed snapshot readings so analytics produced upstream stay synchronized with your KODE OS data model. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [SkySpark](https://kodelabs.com/integration/skyspark/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with SkySpark and access to their API or developer portal * Username and password credentials for the SkySpark system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **SkySpark** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | No | password | The site identifier in the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Version** | Yes | dropdown | The API or firmware version to use | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the SkySpark system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `Gas Meter` | Gas Meter | | `Lighting Meter` | Lighting Meter | | `Water Meter` | Water Meter | | `gas` | gas | | `naturalGas` | naturalGas | | `water` | water | | `lighting` | lighting | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 1 minutes, max: 1 hours) This connector is hybrid: SkySpark can push snapshot readings, and polling intervals apply when KODE OS pulls point history. For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the SkySpark system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the SkySpark system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the SkySpark API. # Smart Meter Texas Source: https://docs.kodelabs.com/products/integrations/meters/smartMeterTexas Connect Smart Meter Texas to KODE OS for 15-minute electric interval reads > Connect Smart Meter Texas to KODE OS for electric meter data ## Overview Use this integration to collect 15-minute electric interval reads and meter details from Smart Meter Texas. Each meter is discovered by ESIID and meter number. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported capabilities * Discover devices and points * Collect sensor data * Collect historical data ## Prerequisites * A Smart Meter Texas API account * The API URL, username, password, and Duns * An agreement number for the meters you want to collect * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Smart Meter Texas`. 3. Select `+ Add Datasource`. 4. Complete the connector fields, then validate credentials so KODE OS can load agreements. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | Smart Meter Texas API base URL | | **Username** | Yes | text | API username | | **Password** | Yes | password | API password | | **Duns** | Yes | password | Duns number used with the API credentials | | **Agreement Number** | Yes | dropdown or text | Agreement to collect. Options load after credentials validate. The field is a text box when no agreements are returned. | | **Notes** | No | text | Additional connection details | KODE OS requests a token with these credentials and refreshes it before it expires. Vendor timestamps use US Central time. ## Discover devices and points After you save the connector, select `Discover`. Review the returned meters and points, then save the records you want in KODE OS. Each meter uses the `electricMeter` canonical type. The device name is the meter number. Consumption and generation points appear only when that meter reports the series. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and points | Point | Description | Unit | Writable | Ontology field | | - | - | - | - | - | | `consumption` | 15-minute consumption interval reads | kWh | No | `total_import_energy_accumulator` | | `generation` | 15-minute generation interval reads | kWh | No | `total_export_energy_accumulator` | | `meterStatus` | Meter status code: `E`, `D`, `e`, `d`, or blank | -- | No | -- | | `disconnect` | Disconnect code: `Y`, `N`, `y`, `n`, `W`, or `w` | -- | No | -- | | `meterPhases` | Meter phase value | -- | No | -- | | `KWHMeterMultiplier` | kWh meter multiplier | -- | No | -- | | `reverseFlowHandling` | Reverse-flow handling: `Y`, `N`, `y`, or `n` | -- | No | -- | ## What data you get ### Point history Each collection requests 15-minute interval reads. A full day has 96 intervals. Spring-forward days have 92, and fall-back days have 100. The default lookback is two days, and one request can cover up to 30 days. Meter status, disconnect, phases, multiplier, and reverse-flow handling are collected with the meter details for the same meter. ### Polling schedule * **Point history** — Default polling: 1 day (min: 1 day, max: 1 day) For more details, see the [Data collection guide](/products/integrations/capabilities/data-collection). ## Use cases Once connected, you can: * Collect 15-minute consumption and generation for Texas electric meters * Review meter status and disconnect codes beside the interval reads * Use the meter data in energy dashboards and reports ## Troubleshooting > [accordion] Authentication or connection error > > Confirm the API URL, username, password, and Duns. Run the connection test again after the token can be refreshed. > [accordion] Agreement Number has no options > > Confirm the credentials can list agreements. If none are returned, type the agreement number into the text field. > [accordion] Discovery returns no meters > > Confirm the selected agreement contains meters available to this account. Save the connector, then run `Discover` again. # Utilivisor Source: https://docs.kodelabs.com/products/integrations/meters/utilivisor Connect Utilivisor to KODE OS for meters data > Connect Utilivisor to KODE OS for meters data integration ## Overview Use this integration to connect Utilivisor utility metering to KODE OS. You can discover meters, poll sensor and non-sensor values on a schedule, and backfill historical intervals for submetering, recharge, and plant-level monitoring in one place. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Utilivisor](https://kodelabs.com/integration/utilivisor/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Utilivisor and access to their API or developer portal * Username and password credentials for the Utilivisor system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Utilivisor** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Utilivisor system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Tenant Invoices Tenant utility invoicing data including consumption-based billing ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) * **TenantInvoice** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Utilivisor system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Utilivisor system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Utilivisor API. # Veolia Source: https://docs.kodelabs.com/products/integrations/meters/veolia Connect Veolia EMSYS or HUBGRADE to KODE OS for historical electric meter data > Connect Veolia EMSYS or HUBGRADE to KODE OS for electric meter data ## Overview Use this integration to collect historical meter readings from the Veolia EMSYS or HUBGRADE platform. The connector brings meter status, cumulative energy, and demand into KODE OS. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported capabilities * Discover devices and points * Collect sensor data * Collect historical data ## Prerequisites * Access to the Veolia Meter Read API * The API and authorization URLs * A client ID and client secret * Access to the required Veolia portfolio * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Veolia API`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | Veolia Meter Read API base URL | | **Auth URL** | Yes | text | URL used to request an access token | | **Client ID** | Yes | text | OAuth client identifier issued by Veolia | | **Client Secret** | Yes | password | OAuth client secret issued by Veolia | | **Portfolio ID** | Yes | dropdown | Veolia portfolio to collect | | **Notes** | No | text | Additional connection details | KODE OS authenticates with the client credentials, then sends a Bearer token on each data request. ## Discover devices and points After you save the connector, select `Discover`. Review the returned meters and points, then save the records you want in KODE OS. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and points Veolia meters map to the `electricMeter` canonical type. | Point | Description | Unit | Writable | Ontology field | | - | - | - | - | - | | `isBilled` | Indicates whether the meter reading is billed | boolean | No | — | | `value` | Cumulative electric energy | kWh | No | `total_electric_energy_accumulator` | | `demand` | Average electric demand | kW | No | `average_power_sensor` | ## What data you get ### Point history The connector collects the same meter-read data available in Veolia EMSYS or HUBGRADE. Veolia updates the API data hourly. ### Polling schedule * **Point history** — Default polling: 15 minutes For more details, see the [Data collection guide](/products/integrations/capabilities/data-collection). ## Use cases Once connected, you can: * Monitor electric meter status and cumulative usage * Analyze historical consumption and demand trends * Use standardized meter data in Building BI dashboards and energy reports ## Troubleshooting > [accordion] Authentication or connection error > > Verify the API URL, authorization URL, client ID, and client secret. Confirm the credentials can access the selected portfolio. > [accordion] Discovery returns no meters > > Confirm the selected portfolio contains meters available to the API client. Test the connection before you run discovery again. > [accordion] The newest meter values are unavailable > > Veolia updates the API data hourly. Allow for this delay before treating a missing recent value as a collection issue. # Verdigris Source: https://docs.kodelabs.com/products/integrations/meters/verdigris Connect Verdigris to KODE OS for meters, weather data > Connect Verdigris to KODE OS for meters, weather data integration ## Overview Use this integration to connect Verdigris electrical metering to KODE OS. You can discover building, panel, breaker, and circuit hierarchies, then pull historical energy metrics (and weather-related context where modeled) for load analysis and efficiency reporting. | Property | Value | | - | - | | **System Type** | Meters, Weather Data | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Verdigris and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Verdigris** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Verdigris system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `temperature` | temperature | | `humidity` | humidity | | `dewPoint` | dewPoint | | `energy` | energy | | `apparent-energy` | apparent-energy | | `power` | power | | `power-factor` | power-factor | | `thd` | thd | | `current` | current | | `voltage` | voltage | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio * Incorporate external weather conditions into building optimization models ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Verdigris platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Verdigris system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Verdigris API. # O3 HUB Source: https://docs.kodelabs.com/products/integrations/meters/waterloo Connect O3 HUB to KODE OS for meters data > Connect O3 HUB to KODE OS for meters data integration ## Overview Use this integration to connect O3 HUB to KODE OS. You can run file-assisted discovery where required, register meters, poll snapshot readings on a schedule, and enable webhooks so timely updates flow into your building data without manual sync. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [O3 HUB](https://kodelabs.com/integration/meterconnex/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with O3 HUB and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the O3 HUB platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **O3 HUB** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the O3 HUB system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the O3 HUB platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the O3 HUB platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the O3 HUB system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the O3 HUB system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the O3 HUB API. # Wattics Source: https://docs.kodelabs.com/products/integrations/meters/wattics Connect Wattics to KODE OS for meters data > Connect Wattics to KODE OS for meters data integration ## Overview Use this integration to connect your Wattics energy management platform to KODE OS. You can discover meters, collect consumption data on a schedule, and receive real-time webhook events for alerts and notifications. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Wattics and access to their API or developer portal * API key or token from the Wattics platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Wattics platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in KODE OS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Wattics platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in KODE OS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Wattics** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Organization ID** | Yes | text | The organization ID in the vendor's API | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Wattics system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in KODE OS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Wattics, KODE OS maps them to the following device types and data points: ### Meter Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `totalConsumption` | Total energy consumption | -- | No | Webhook | | 2 | `totalCost` | Total cost of energy consumed (\$) | dollars | No | Webhook | ## What Data You Get ### Point History Time-series readings including totalConsumption, totalCost, collected at regular intervals from connected devices. If Wattics has removed a device or point, point history collection skips that item. Collection continues for the remaining devices, and the connector stays up. ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Wattics data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `(formatted)` | -- | | **name** | `event_type` | -- | | **startedAt** | `data.start_date` | transformed | | **completedAt** | `data.end_date` | transformed | | **id** | `(formatted)` | -- | | **name** | `event_type` | -- | | **description** | `notice` | -- | | **startedAt** | `start_date` | transformed | | **completedAt** | `end_date` | transformed | | **customFields** | mapped by connector | -- | ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Wattics platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Wattics platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Wattics system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Wattics system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Wattics API. # Wyse Meter Source: https://docs.kodelabs.com/products/integrations/meters/wyseMeter Connect Wyse Meter to KODE OS for meters data > Connect Wyse Meter to KODE OS for meters data integration ## Overview Use this integration to connect Wyse Meter to KODE OS. You can discover utility meters exposed by the API, then pull historical consumption and related metrics on a schedule for cost tracking, sustainability reporting, and operational dashboards. | Property | Value | | - | - | | **System Type** | Meters | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Wyse Meter](https://kodelabs.com/integration/wyse/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points ## Prerequisites * An active account with Wyse Meter and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Wyse Meter developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Wyse Meter developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Wyse Meter** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Location IDs** | Yes | text | Comma-separated list of location identifiers to monitor | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Wyse Meter system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Wyse Meter, KODE OS maps them to the following device types and data points: ### Electric Meter Canonical Type: `electricMeter` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Current_Reading` | Current meter reading | -- | No | Polling | | 2 | `Net_Reading` | Net meter reading (import minus export) | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Current\_Reading, Net\_Reading, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Aggregate utility consumption data (electricity, gas, water, steam) in a unified dashboard * Detect abnormal consumption patterns and potential waste or leaks * Generate utility cost reports and benchmark buildings in your portfolio ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Wyse Meter developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Wyse Meter system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Wyse Meter API. # Venn City Source: https://docs.kodelabs.com/products/integrations/notifications/vennCity Connect Venn City to KODE OS for notifications data > Connect Venn City to KODE OS for notifications data integration ## Overview Use this integration to connect Venn City resident lifecycle events to KODE OS. Push collection and supported actions help you automate notifications and workflows tied to leasing and move activity. | Property | Value | | - | - | | **System Type** | Notifications | | **Communication** | REST | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Venn City](https://kodelabs.com/integration/venn/) on the KODE Labs Integrations Library. ## Prerequisites * An active account with Venn City and access to their API or developer portal * API key or token from the Venn City platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Venn City platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Venn City** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **User Key** | Yes | password | The user-specific key from the vendor platform | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Location ID** | Yes | password | The location identifier in the external system | ## What Data You Get ### Notifications Outbound notification dispatch to external notification platforms ## Available Actions This integration supports actions that allow you to send commands to the Venn City system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize Venn City data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Venn City platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Venn City API. # A1 Innovation Group Source: https://docs.kodelabs.com/products/integrations/occupancy/a1IG Connect A1 Innovation Group to KODE OS for occupancy data > Connect A1 Innovation Group to KODE OS for occupancy data integration ## Overview Use this integration to connect A1 Innovation Group occupancy systems to KODE OS. You can discover sensors and points, then pull historical occupancy readings for utilization reporting and operational dashboards. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [A1 Innovation Group](https://kodelabs.com/integration/a1-innovation-group/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with A1 Innovation Group and access to their API or developer portal * Username and password credentials for the A1 Innovation Group system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **A1 Innovation Group** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Location ID** | Yes | text | The location identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the A1 Innovation Group system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from A1 Innovation Group, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `currentOccupancy` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | | 2 | `occupancyLevel` | Current occupancy utilization level | -- | No | -- | Polling | | 3 | `percentage` | Value expressed as a percentage (%) | % | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including currentOccupancy, occupancyLevel, percentage, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the A1 Innovation Group system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the A1 Innovation Group system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the A1 Innovation Group API. # Abakus Source: https://docs.kodelabs.com/products/integrations/occupancy/abakus Connect Abakus to KODE OS for occupancy data > Connect Abakus to KODE OS for occupancy data integration ## Overview Use this integration to connect Abakus Analytics people counting to KODE OS. You can discover counters and zones, then collect historical inflow and presence-style metrics so space planning decisions use the same data as the rest of your building stack. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Abakus](https://kodelabs.com/integration/abakus-analytics/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Abakus and access to their API or developer portal * API key or token from the Abakus platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Abakus platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Abakus** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Report ID** | Yes | text | The report identifier for data export | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Abakus system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `Occupancy` | Occupancy | | `trafficCounter/` | trafficCounter/ | | `bikeCounter/` | bikeCounter/ | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Abakus platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Abakus system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Abakus API. # Avuity Source: https://docs.kodelabs.com/products/integrations/occupancy/avuity Connect Avuity to KODE OS for occupancy, indoor environmental quality data > Connect Avuity to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect Avuity to KODE OS. You can discover space and sensor assets, then pull snapshot occupancy alongside indoor environmental quality points so workplace utilization and comfort signals stay aligned in one model. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Avuity](https://kodelabs.com/integration/avuity/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Avuity and access to their API or developer portal * API key or token from the Avuity platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Avuity platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Avuity** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Token** | Yes | password | The API token for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Avuity system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Avuity, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `occupancy` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | | 2 | `capacity` | Maximum people capacity threshold | count | No | `threshold_people_capacity` | Polling | | 3 | `isActive` | **True** -- isActive is active / **False** -- isActive is not active | -- | No | -- | Polling | ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `temperature` | Current temperature reading (°F) | °F | No | `zone_air_temperature_sensor` | Polling | | 2 | `humidity` | Relative humidity level (humidity) | humidity | No | `zone_air_humidity_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including occupancy, capacity, isActive, temperature, humidity, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Avuity platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Avuity system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Avuity API. # Butlr Source: https://docs.kodelabs.com/products/integrations/occupancy/butlr Connect Butlr to KODE OS for occupancy data > Connect Butlr to KODE OS for occupancy data integration ## Overview Use this integration to connect Butlr occupancy sensors to KODE OS. You can discover zones and devices, receive pushed webhook updates for live conditions, and map people counts, heatmaps, and zone occupancy into your building graph for analytics and operations. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Butlr](https://kodelabs.com/integration/butlr/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * Collect Historical Data ## Prerequisites To integrate with the Butlr API, ensure you have the following details: * An active account in [https://app.butlr.io](https://app.butlr.io) with the appropriate access permissions. * Valid username and password credentials for Butlr platform. ## Generate API Credentials * Go to the Butlr Web App. * Sign in using your username and password. * Click the expandable menu (v) in the top navigation bar (upper right corner) and select Account Settings. * Navigate to the API tokens tab. * Click the Create token button. * Enter a Name and a Description, then click Create. * A dialog box will display your Client ID and Client Secret. After completing the steps above, your Client ID and Client Secret will be used in the next step. ⬇️ ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Butlr platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Butlr** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Butlr system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Butlr, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `count` | Number of people/objects currently detected | -- | No | `occupancy_count` | Webhook | | 2 | `status` | Current operating status | -- | No | `connection_status` | Webhook | | 3 | `in` | Cumulative count of people entering | -- | No | `people_entering_counter` | Webhook | | 4 | `out` | Cumulative count of people exiting | -- | No | `people_leaving_counter` | Webhook | ## What Data You Get ### Point History Time-series readings including count, status, in, out, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Butlr data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | mapped by connector | -- | | **name** | `code` | -- | | **description** | `description` | -- | | **deviceId** | `deviceId` | -- | | **deviceName** | `deviceName` | -- | | **createdAt** | `lastTimestamp` | -- | | **customFields** | `deviceType` | -- | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **EventLog** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Butlr platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Butlr platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Butlr system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Butlr system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Butlr API. # Density Source: https://docs.kodelabs.com/products/integrations/occupancy/density Connect Density to KODE OS for occupancy data > Connect Density to KODE OS for occupancy data integration ## Overview Use this integration to connect your Density occupancy sensors to KODE OS. You can discover traffic counters and presence sensors, then collect real-time people counts and space utilization data across your building. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Density](https://kodelabs.com/integration/density/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites To integrate with the Density API, ensure you have the following details: * An active account in [https://atlas.density.io](https://atlas.density.io) with the appropriate access permissions. * Valid username and password credentials for the Atlas platform. ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Density API quick start](https://developers.density.io/quick_start) * [Density API reference](https://developers.density.io/docs/) ## Generate API Credentials * Log in to the atlas.density.io using your username and password * Click the gear icon on the bottom-left corner * Select Developer * Click on the desired token to copy it to your clipboard * If you do not see the desired token, click Add Token at the top right * Input the required information and select if it will be a read-only or a read-write token, and then click Save After completing the steps above, your API Token will be used in the next step. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Density** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Token** | Yes | password | The API token for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Density system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Density, KODE OS maps them to the following device types and data points: ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `status` | **True** -- active / **False** -- inactive | -- | No | Polling | | 2 | `entrance` | Cumulative count of people entering | count | No | Polling | | 3 | `exit` | Cumulative count of people exiting | count | No | Polling | ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `capacity` | Maximum capacity of the space | count | No | Polling | | 2 | `current_count` | Cumulative count of events | count | No | Polling | ## What Data You Get ### Point History Time-series readings including status, entrance, exit, capacity, current\_count, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 5 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Density platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Density system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Density API. # Enlighted People Counting Source: https://docs.kodelabs.com/products/integrations/occupancy/enlightedPeopleCounting Connect Enlighted People Counting to KODE OS for occupancy data > Connect Enlighted People Counting to KODE OS for occupancy data integration ## Overview Use this integration to connect Enlighted people counting to KODE OS. You can discover entrance and exit counters on the Enlighted network, then pull historical in/out counts and utilization metrics for floors, rooms, and shared spaces. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Enlighted People Counting](https://kodelabs.com/integration/enlighted-people-counting/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites To integrate with the Enlighted API, ensure you have the following details: * An active account in [https://accessmanager.dsp.enlightedinc.com](https://accessmanager.dsp.enlightedinc.com) with the appropriate access permissions. * Valid username and password credentials for the Enlighted platform. ## Generate API Credentials * Log in to [https://accessmanager.dsp.enlightedinc.com](https://accessmanager.dsp.enlightedinc.com) using your username and password, or via Google Single Sign-On (SSO). * On the Enlighted People Counting dashboard, click the Security tab. * Under the API Key section, select your preferred expiration period, then click Generate New API Key. * The API Key will appear below the expiration settings. * Warning: This is a one-time view only. Be sure to copy the API Key immediately and store it securely. If lost, a new key will need to be generated. After completing the steps above, your API Key will be used in the next step. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Enlighted People Counting** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Enlighted People Counting system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Enlighted People Counting, KODE OS maps them to the following device types and data points: ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `new_entries` | Cumulative count of people entering | count | No | `people_entering_counter` | Polling | | 2 | `new_exits` | Cumulative count of people exiting | count | No | `people_leaving_counter` | Polling | | 3 | `space_capacity` | Maximum people capacity threshold | count | No | `threshold_people_capacity` | Polling | | 4 | `space_availability` | Number of currently available spaces | count | No | `total_unoccupied_count` | Polling | | 5 | `occupancy_ratio` | Current occupancy ratio (occupied / capacity) | -- | No | -- | Polling | | 6 | `occupancy_ratio_avg` | Average occupancy ratio for the period | -- | No | -- | Polling | | 7 | `occupancy_ratio_max` | Maximum occupancy ratio for the period | -- | No | -- | Polling | | 8 | `occupancy_ratio_min` | Minimum occupancy ratio for the period | -- | No | -- | Polling | | 9 | `people_count` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | | 10 | `people_count_avg` | Average number of people detected during the period | count | No | -- | Polling | | 11 | `people_count_max` | Maximum number of people detected during the period | count | No | -- | Polling | | 12 | `people_count_min` | Number of people currently detected in the space | count | No | -- | Polling | | 13 | `reset_point` | Counter reset reference value | count | No | -- | Polling | | 14 | `total_entries` | Cumulative count of people entering | count | No | `people_entering_counter` | Polling | | 15 | `total_exits` | Cumulative count of people exiting | count | No | `people_leaving_counter` | Polling | ## What Data You Get ### Point History Time-series readings including new\_entries, new\_exits, space\_capacity, space\_availability, occupancy\_ratio, occupancy\_ratio\_avg, occupancy\_ratio\_max, occupancy\_ratio\_min, and 7 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Enlighted People Counting platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Enlighted People Counting system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Enlighted People Counting API. # Extron Source: https://docs.kodelabs.com/products/integrations/occupancy/extron Connect Extron to KODE OS for occupancy data > Connect Extron to KODE OS for occupancy data integration ## Overview Use this integration to connect Extron occupancy interfaces to KODE OS. You can discover devices and points, then collect snapshot occupancy sensor data on your configured polling schedule for AV and facilities workflows. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Extron and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Extron** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Extron system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Extron, KODE OS maps them to the following device types and data points: ### Occupancy Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `occupancyState` | Current occupancy state of the zone | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including occupancyState, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Extron platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Extron system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Extron API. # Framery Source: https://docs.kodelabs.com/products/integrations/occupancy/framery Connect Framery smart pods and sensor-equipped spaces to KODE OS for occupancy, status, and usage sessions > Connect Framery smart pods and sensor-equipped spaces to KODE OS ## Overview Use this integration to monitor Framery pod occupancy and connection status. You can also collect usage sessions with duration, capacity, and people-count details. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT and HISTORICAL | ## Supported capabilities * Discover devices and points * Collect current occupancy and connection status * Collect usage sessions * Collect up to 12 months of session history ## Prerequisites * Access to the [Framery developer platform](https://developers.framery.com/) * A Framery API key * The Framery workspace ID * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Framery`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | Framery API base URL | | **API Key** | Yes | password | API key sent with each request | | **Workspace ID** | Yes | text | Framery workspace to collect | | **Notes** | No | text | Additional connection details | ## Discover devices and points After you save the connector, select `Discover`. KODE OS retrieves Framery spaces in pages of up to 200 records. Review the returned spaces and points, then save the records you want in KODE OS. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and points Each Framery space becomes an occupancy device. | Point | Description | Values | Writable | Collection | | - | - | - | - | - | | `occupancy` | Current occupancy state | `occupied`, `available` | No | Snapshot | | `status` | Current connection state | `online`, `offline` | No | Snapshot | ### Polling schedule * **Occupancy and status** — Every 30 seconds * **Usage sessions** — Every 10 minutes ## What data you get ### Usage sessions | KODE field | Framery field | | - | - | | `location` | `buildingName` and `floorName` | | `createdAt` | `start` | | `updatedAt` | `end` | | `deviceId` | `spaceId` | | `deviceName` | `spaceName` | | `duration` | `durationSeconds` | | `space_capacity` | `spaceCapacity` | | `people_count_median` | `peopleCountMedian` | | `people_count_accuracy` | `peopleCountAccuracy` | KODE OS runs a daily sync for the previous 24 hours to capture sessions that were still open during normal collection. ### Historical collection You can collect up to 12 months of previous session data. Each historical task covers up to 30 days. ## Use cases Once connected, you can: * Monitor pod availability and connection health * Analyze usage duration and people counts * Compare utilization across pods, floors, and buildings ## Troubleshooting > [accordion] Authentication or connection error > > Verify the API URL, API key, and workspace ID. Confirm the credentials pass Framery's authenticated health check. > [accordion] Discovery stops before all spaces load > > Review the connector logs for pagination errors. Framery returns a maximum of 200 spaces per page. > [accordion] Recent sessions are missing an end time > > A session may remain open while the space is occupied. The daily sync reviews the previous 24 hours and captures completed session details. # Freespace Source: https://docs.kodelabs.com/products/integrations/occupancy/freeSpace Connect Freespace to KODE OS for occupancy, indoor environmental quality data > Connect Freespace to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect Freespace to KODE OS. You can discover areas and sensors (including file-assisted discovery where required), then pull snapshot occupancy and related indoor environmental quality points for utilization reporting. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Freespace](https://kodelabs.com/integration/freespace/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * File Validation ## Prerequisites * An active account with Freespace and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Freespace developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Freespace developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Freespace** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Freespace system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Freespace, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `count` | Number of people/objects currently detected | count | No | `occupancy_count` | Polling | | 2 | `value` | Current occupancy status | -- | No | `occupancy_status` | Polling | | 3 | `occupancyStatus` | Current occupancy status of the space | -- | No | `occupancy_status` | Polling | | 4 | `occupancyLevel` | Current occupancy utilization level | -- | No | `occupancy_label` | Polling | | 5 | `occupancyNow` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `pm10` | Coarse particulate matter (PM10) concentration | -- | No | `pm10_concentration_detection_sensor` | Polling | | 2 | `vocIndexSGP40` | Volatile organic compound (VOC) level | -- | No | -- | Polling | | 3 | `co2SCD40` | CO₂ concentration (ppm) | ppm | No | `co2_concentration_detection_sensor` | Polling | | 4 | `humidityBME688` | Relative humidity level (%) | % | No | `zone_air_humidity_sensor` | Polling | | 5 | `vocRawSGP40` | Volatile organic compound (VOC) level | -- | No | `voc_concentration_detection_sensor` | Polling | | 6 | `humiditySCD40` | Humidity reading from SCD40 sensor (%) | % | No | `zone_air_humidity_sensor` | Polling | | 7 | `ch2oProcessed` | Processed formaldehyde (HCHO) concentration | -- | No | -- | Polling | | 8 | `pm2_5` | Fine particulate matter (PM2.5) concentration | -- | No | `pm25_concentration_detection_sensor` | Polling | | 9 | `temperatureBME688` | Temperature reading from BME688 sensor (°C) | °C | No | `zone_air_temperature_sensor` | Polling | | 10 | `ch2oRaw` | Raw formaldehyde (HCHO) sensor reading | -- | No | -- | Polling | | 11 | `temperatureSCD40` | Temperature reading from SCD40 sensor (°C) | °C | No | `zone_air_temperature_sensor` | Polling | ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `entriesToday` | Cumulative count of people entering | count | No | `people_entering_counter` | Polling | | 2 | `exitsToday` | Cumulative count of people exiting | count | No | `people_leaving_counter` | Polling | | 3 | `maxOccupancyToday` | Peak occupancy count for the current day | count | No | -- | Polling | | 4 | `avgOccupancyToday` | Average occupancy count for the current day | count | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including count, value, occupancyStatus, occupancyLevel, occupancyNow, pm10, vocIndexSGP40, co2SCD40, and 12 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Freespace developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Freespace system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Freespace API. # Freespace Utilization (V2) Source: https://docs.kodelabs.com/products/integrations/occupancy/freeSpaceUtilization Connect Freespace Utilization (V2) to KODE OS for occupancy data > Connect Freespace Utilization (V2) to KODE OS for occupancy data integration ## Overview Use this integration to connect the Freespace Utilization API (V2) to KODE OS. You can discover spaces and counters, then ingest historical occupancy and people-count trends for portfolio-wide utilization analytics. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Freespace Utilization (V2) and access to their API or developer portal * Username and password credentials for the Freespace Utilization (V2) system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Freespace Utilization (V2)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **External URL** | Yes | text | An additional external URL for the integration | | **Username** | Yes | password | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Freespace Utilization (V2) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Freespace Utilization (V2), KODE OS maps them to the following device types and data points: ### Occupancy Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `spaceCount` | Cumulative count of events | -- | No | Polling | | 2 | `maxOccupied` | Peak number of occupied spaces | -- | No | Polling | | 3 | `averageOccupied` | Average number of occupied spaces | -- | No | Polling | | 4 | `minFree` | Minimum number of free spaces during the period | -- | No | Polling | | 5 | `unused` | Number of spaces that went unused | -- | No | Polling | | 6 | `utilisation` | Space utilization rate (%) | % | No | Polling | | 7 | `efficiency` | Space usage efficiency (%) | % | No | Polling | | 8 | `averageLoad` | Average load/occupancy level | -- | No | Polling | | 9 | `maxLoad` | Maximum load/occupancy level | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including spaceCount, maxOccupied, averageOccupied, minFree, unused, utilisation, efficiency, averageLoad, and 1 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Freespace Utilization (V2) system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Freespace Utilization (V2) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Freespace Utilization (V2) API. # Fyma Source: https://docs.kodelabs.com/products/integrations/occupancy/fyma Connect Fyma to KODE OS for occupancy data > Connect Fyma to KODE OS for occupancy data integration ## Overview Use this integration to connect Fyma camera-based analytics to KODE OS. You can discover vision-derived entities from your existing cameras, then pull snapshot occupancy, movement, and related utilization signals without deploying separate people-counting hardware. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Fyma](https://kodelabs.com/integration/fyma/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Fyma and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Fyma developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Fyma developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Fyma** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Version** | Yes | dropdown | The API or firmware version to use | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Location IDs** | Yes | text | Comma-separated list of location identifiers to monitor | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Fyma system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Fyma, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `occupancy` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | | 2 | `Zone` | Accumulated time in current occupancy state | seconds | No | `occupancy_time_accumulator` | Polling | ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Gate` | Cumulative count of gate crossings | count | No | Polling | ### Camera Canonical Type: `camera` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `is Enabled` | **True** -- device is running / **False** -- device is stopped | -- | No | `run_status` | Polling | ## What Data You Get ### Point History Time-series readings including occupancy, Zone, Gate, is Enabled, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Fyma developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Fyma system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Fyma API. # Hella Aglaia Source: https://docs.kodelabs.com/products/integrations/occupancy/hellaAglaia Connect Hella Aglaia to KODE OS for occupancy data > Connect Hella Aglaia to KODE OS for occupancy data integration ## Overview Use this integration to connect Hella Aglaia occupancy sensors to KODE OS. You can discover devices and points, then collect snapshot presence and count readings on a schedule for lighting, HVAC, and space analytics. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Hella Aglaia](https://kodelabs.com/integration/hella-aglaia/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Hella Aglaia and access to their API or developer portal * Username and password credentials for the Hella Aglaia system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Hella Aglaia** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Hella Aglaia system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Hella Aglaia, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `count` | Number of people/objects currently detected | count | No | `occupancy_count` | Polling | | 2 | `maxFillLevel` | Container fill level as a percentage (0–100%) | count | No | -- | Polling | | 3 | `maxDwell` | Accumulated time in current occupancy state | seconds | No | `occupancy_time_accumulator` | Polling | | 4 | `meanDwell` | Accumulated time in current occupancy state | seconds | No | `occupancy_time_accumulator` | Polling | ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `in` | Cumulative count of people entering | count | No | `people_entering_counter` | Polling | | 2 | `out` | Cumulative count of people exiting | count | No | `people_leaving_counter` | Polling | ## What Data You Get ### Point History Time-series readings including count, maxFillLevel, maxDwell, meanDwell, in, out, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Hella Aglaia system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Hella Aglaia system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Hella Aglaia API. # Impark Source: https://docs.kodelabs.com/products/integrations/occupancy/impark Connect Impark to KODE OS for occupancy data > Connect Impark to KODE OS for occupancy data integration ## Overview Use this integration to connect Impark parking systems to KODE OS over TCP/IP. You can discover parking assets and points, then pull historical occupancy or availability-style readings so garage and campus views match your other building data. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Impark](https://kodelabs.com/integration/impark/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * Network access to the Impark controller or device * The IP address and port of the on-site system * Login credentials for the Impark system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Impark** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Host** | Yes | text | The host address for the connection | | **Port** | Yes | text | The port number for connecting to the system | | **Database Name** | Yes | text | The database name to connect to | | **Schema** | Yes | text | The database schema to use | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Lot ID** | Yes | text | The parking lot identifier | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Impark system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Impark, KODE OS maps them to the following device types: * **Presence / Occupancy Sensor** (`presenceDetection`) * **Traffic Counter** (`trafficCounter`) ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the Impark controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Impark system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Impark API. # ITS Cloud Camera Source: https://docs.kodelabs.com/products/integrations/occupancy/itsCloudCamera Connect ITS Cloud Camera to KODE OS for occupancy, camera data > Connect ITS Cloud Camera to KODE OS for occupancy, camera data integration ## Overview Use this integration to connect ITS Cloud Camera analytics to KODE OS. You can discover camera-related devices, then pull historical object classification, tracking, and occupancy-oriented telemetry so video-derived insights map to your spaces. | Property | Value | | - | - | | **System Type** | Occupancy, Camera | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with ITS Cloud Camera and access to their API or developer portal * Username and password credentials for the ITS Cloud Camera system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **ITS Cloud Camera** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the ITS Cloud Camera system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from ITS Cloud Camera, KODE OS maps them to the following device types: * **Presence / Occupancy Sensor** (`presenceDetection`) | Point | Display Name | | - | - | | `total` | total | | `avgSpeed` | avgSpeed | | `idle` | idle | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Integrate video surveillance feeds into the building operations dashboard ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the ITS Cloud Camera system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the ITS Cloud Camera system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the ITS Cloud Camera API. # Kontakt Source: https://docs.kodelabs.com/products/integrations/occupancy/kontakt Connect Kontakt to KODE OS for occupancy data > Connect Kontakt to KODE OS for occupancy data integration ## Overview Use this integration to connect Kontakt.io BLE beacons and indoor location to KODE OS. You can discover beacon and sensor assets, then collect snapshot presence and proximity data for occupancy, wayfinding, and safety workflows. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Kontakt](https://kodelabs.com/integration/kontakt/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Kontakt and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kontakt** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Kontakt system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Kontakt platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Kontakt system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kontakt API. # Lambent Spaces Source: https://docs.kodelabs.com/products/integrations/occupancy/lambent Connect Lambent Spaces to KODE OS for Wi-Fi-derived occupancy, utilization, and capacity data > Connect Lambent Spaces to KODE OS for floor and zone occupancy analytics ## Overview Use this integration to collect Wi-Fi-derived occupancy and utilization metrics from Lambent Spaces. The connector creates devices for building levels and zones without requiring additional occupancy sensors. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported capabilities * Discover levels and zones from occupancy data * Collect occupancy, utilization, and capacity * Collect historical point data ## Prerequisites * Lambent Spaces Analyze API access * An OAuth client ID and client secret * The API and Auth0 authorization URLs * The `Tenant ID` when your credentials require one * KODE OS access to `Data Sources` ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `Lambent`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | object | Area associated with the connection | | **URL** | Yes | text | Lambent Analyze API base URL | | **Auth URL** | Yes | text | Auth0 token URL | | **Client ID** | Yes | text | OAuth client identifier | | **Client Secret** | Yes | password | OAuth client secret | | **Tenant ID** | No | text | Tenant identifier sent with occupancy requests | | **Notes** | No | text | Additional connection details | The authorization URL may use the former Armored Things name. KODE OS exchanges the client credentials for a Bearer token. ## Discover devices and points Lambent does not provide a separate directory endpoint. KODE OS discovers levels and zones from occupancy rows reported during the previous 24 hours. After you save the connector, select `Discover`. Review the returned levels, zones, and points, then save the records you want. > [!NOTE] > > A space without occupancy data during the discovery window does not appear. Run discovery again after the space reports data. ## Devices and points KODE OS creates `LEVEL` devices for building floors and `ZONE` devices for areas within each floor. | Point | Description | Unit | Writable | | - | - | - | - | | `mean_occupancy` | Average estimated headcount during the interval | people | No | | `peak_occupancy` | Maximum estimated headcount during the interval | people | No | | `mean_utilization` | Average occupancy relative to configured capacity | % | No | | `peak_utilization` | Peak occupancy relative to configured capacity | % | No | | `capacity` | Capacity configured in Lambent | people | No | Utilization arrives as a ratio and is stored as a percentage from zero through 100. KODE OS does not store a value when Lambent returns `null`. ## What data you get ### Point history Lambent reports 15-minute occupancy intervals. KODE OS polls every 30 minutes and uses overlapping windows to account for the vendor's 30-to-60-minute data delay. Historical retention depends on the space type: * **Levels** — Up to eight months at 15-minute resolution * **Zones** — Up to two weeks at 15-minute resolution ### Rate limits Each occupancy endpoint allows 60 requests per minute. KODE OS bounds historical batches to preserve capacity for scheduled collection and discovery. ## Use cases Once connected, you can: * Compare mean and peak occupancy by floor or zone * Identify underused spaces using utilization percentages * Build portfolio occupancy reports without deploying additional sensors ## Troubleshooting > [accordion] Authentication or connection error > > Verify the API URL, Auth0 URL, client ID, and client secret. For a workspace-scoped credential, confirm the `Tenant ID`. > [accordion] Discovery misses a level or zone > > The space must report occupancy during the 24-hour discovery window. Run discovery again after the space produces data. > [accordion] The newest interval is missing > > Lambent data normally trails real time by 30 to 60 minutes. Wait for the next polling cycle before treating the interval as missing. > [accordion] Utilization or capacity is blank > > Confirm the space has a capacity in Lambent. The API returns `null` for utilization and capacity when no capacity is configured. # Nimway Source: https://docs.kodelabs.com/products/integrations/occupancy/nimway Connect Nimway to KODE OS for occupancy, indoor environmental quality data > Connect Nimway to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect Nimway smart-office data to KODE OS. You can discover desks, rooms, and sensors, combine scheduled polling with webhooks for fresher state, and unify occupancy with booking and navigation signals where the API exposes them. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Nimway and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Nimway developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Nimway developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Nimway platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Nimway** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Nimway system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Nimway, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `occupancy` | **free** -- space is available / **occupied** -- space is currently in use | -- | No | `map` | Webhook | | 2 | `peopleCount` | Number of people currently detected in the space | -- | No | `map` | Webhook | | 3 | `accuracy` | Measurement accuracy confidence level | -- | No | -- | Webhook | ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `level` | Current occupancy level | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including occupancy, peopleCount, accuracy, level, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Nimway developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Nimway platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Nimway system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Nimway system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Nimway API. # Point Grab Source: https://docs.kodelabs.com/products/integrations/occupancy/pointGrab Connect Point Grab to KODE OS for occupancy, indoor environmental quality data > Connect Point Grab to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect PointGrab space analytics to KODE OS. You can discover zones and sensors, poll utilization and IEQ-related points on a schedule, and register webhooks so occupancy updates arrive when conditions change. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Point Grab](https://kodelabs.com/integration/point-grab/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Point Grab and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Point Grab developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Point Grab developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Point Grab platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Point Grab** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Site ID** | Yes | text | The site identifier in the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Point Grab system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Point Grab, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `pressure` | Static air pressure (pascals) | pascals | No | `zone_air_static_pressure_sensor` | Webhook | | 2 | `humidity` | Relative humidity level (humidity) | humidity | No | `zone_air_humidity_sensor` | Webhook | | 3 | `temperature` | Current temperature reading (°C) | °C | No | `zone_air_temperature_sensor` | Webhook | | 4 | `connectionStatus` | Device connectivity status | -- | No | `connection_status` | Webhook | ### Traffic Counter Canonical Type: `trafficCounter` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `inNumber` | Cumulative count of people entering | count | No | `people_entering_counter` | Webhook | | 2 | `outNumber` | Cumulative count of people exiting | count | No | `people_leaving_counter` | Webhook | ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `count` | Number of people/objects currently detected | count | No | `occupancy_count` | Webhook | ## What Data You Get ### Point History Time-series readings including pressure, humidity, temperature, connectionStatus, inNumber, outNumber, count, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Point Grab developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Point Grab platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Point Grab system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Point Grab system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Point Grab API. # Sembient Source: https://docs.kodelabs.com/products/integrations/occupancy/sembient Connect Sembient to KODE OS for occupancy, indoor environmental quality data > Connect Sembient to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect Sembient to KODE OS. You can discover occupancy and environmental devices, collect snapshot readings on your polling cadence, and receive webhook payloads for faster operational response alongside IEQ context. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Sembient](https://kodelabs.com/integration/sembient/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Sembient and access to their API or developer portal * Username and password credentials for the Sembient system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Sembient platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Sembient** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Sembient system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Sembient, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `motion_detection_sensor` | **True** -- motion detected / **False** -- no motion detected | -- | No | Webhook | | 2 | `occupancy_count` | Cumulative count of events | -- | No | Webhook | | 3 | `zone_air_temperature_sensor` | Current temperature reading (°F) | °F | No | Webhook | | 4 | `zone_air_humidity_sensor` | Relative humidity level (%RH) | %RH | No | Webhook | ## What Data You Get ### Point History Time-series readings including motion\_detection\_sensor, occupancy\_count, zone\_air\_temperature\_sensor, zone\_air\_humidity\_sensor, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Sembient system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Sembient platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Sembient system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Sembient system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Sembient API. # Sighthound camera Source: https://docs.kodelabs.com/products/integrations/occupancy/sighthound Connect Sighthound camera to KODE OS for occupancy data > Connect Sighthound camera to KODE OS for occupancy data integration ## Overview Use this integration to connect Sighthound camera analytics to KODE OS. You can discover vision endpoints, collect occupancy-oriented readings on a schedule, and enable webhooks so detections and events propagate without waiting for the next poll. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Sighthound camera](https://kodelabs.com/integration/sighthound/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Sighthound camera and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Sighthound camera platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Sighthound camera** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Sighthound camera system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Sighthound camera, KODE OS maps them to the following device types: * **Traffic Counter** (`trafficCounter`) ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Sighthound camera platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Sighthound camera platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Sighthound camera system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Sighthound camera system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Sighthound camera API. # Trax Source: https://docs.kodelabs.com/products/integrations/occupancy/trax Connect Trax to KODE OS for occupancy, smart bathroom, indoor environmental quality data > Connect Trax to KODE OS for occupancy, smart bathroom, indoor environmental quality data integration ## Overview Use this integration to connect Trax to KODE OS. You can discover restroom and environmental sensors, then pull snapshot occupancy alongside smart-bathroom and IEQ points so facilities teams see utilization, hygiene, and comfort in one model. | Property | Value | | - | - | | **System Type** | Occupancy, Smart Bathroom, Indoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Trax](https://kodelabs.com/integration/trax/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Trax and access to their API or developer portal * API key or token from the Trax platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Trax platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Trax** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Venue ID** | Yes | password | The venue identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Trax system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor restroom fixture usage and supply levels in real time ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Trax platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Trax system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Trax API. # Verge Sense Source: https://docs.kodelabs.com/products/integrations/occupancy/vergeSense Connect Verge Sense to KODE OS for occupancy data > Connect Verge Sense to KODE OS for occupancy data integration ## Overview Use this integration to connect VergeSense workplace sensors to KODE OS. You can discover spaces and devices, mix scheduled polling with webhooks for hybrid collection, and consolidate real-time occupancy and utilization metrics with non-sensor context where exposed. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Verge Sense](https://kodelabs.com/integration/verge-sense/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * Collect Historical Data * Webhook Verification ## Prerequisites * An active account with Verge Sense and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Verge Sense platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Verge Sense** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Verge Sense system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Verge Sense, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `capacity_hourly` | Hourly space capacity | -- | No | Webhook | | 2 | `avg_person_count_hourly` | Average person count per hour | -- | No | Webhook | | 3 | `min_person_count_hourly` | Minimum person count during the hour | -- | No | Webhook | | 4 | `max_person_count_hourly` | Maximum person count during the hour | -- | No | Webhook | | 5 | `minutes_actively_occupied_hourly` | Minutes the space was actively occupied per hour | -- | No | Webhook | | 6 | `minutes_passively_occupied_hourly` | Minutes the space was passively occupied per hour | -- | No | Webhook | | 7 | `avg_pct_utilization_hourly` | Average utilization percentage per hour | -- | No | Webhook | | 8 | `min_pct_utilization_hourly` | Minimum utilization percentage during the hour | -- | No | Webhook | | 9 | `max_pct_utilization_hourly` | Maximum utilization percentage during the hour | -- | No | Webhook | | 10 | `pct_time_actively_occupied_hourly` | Percentage of the hour the space was actively occupied | -- | No | Webhook | | 11 | `pct_time_passively_occupied_hourly` | Percentage of the hour the space was passively occupied | -- | No | Webhook | | 12 | `person_count` | Cumulative count of events | -- | No | Webhook | | 13 | `motion_detected` | **True** -- motion detected / **False** -- no motion detected | -- | No | Webhook | | 14 | `signs_of_life` | **True** -- signs\_of\_life is active / **False** -- signs\_of\_life is not active | -- | No | Webhook | | 15 | `state` | Current operating state | -- | No | Webhook | | 16 | `passively_occupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | Webhook | | 17 | `avg_person_count` | Cumulative count of events | -- | No | Webhook | | 18 | `min_person_count` | Cumulative count of events | -- | No | Webhook | | 19 | `max_person_count` | Cumulative count of events | -- | No | Webhook | | 20 | `minutes_actively_occupied` | Total minutes actively occupied | -- | No | Webhook | | 21 | `minutes_passively_occupied` | Total minutes passively occupied | -- | No | Webhook | | 22 | `mode_person_count` | Cumulative count of events | -- | No | Webhook | | 23 | `avg_person_count_when_used` | Average person count when the space was in use | -- | No | Webhook | | 24 | `network_status` | Current network connectivity status | -- | No | Webhook | | 25 | `battery_status` | Device battery status | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including capacity\_hourly, avg\_person\_count\_hourly, min\_person\_count\_hourly, max\_person\_count\_hourly, minutes\_actively\_occupied\_hourly, minutes\_passively\_occupied\_hourly, avg\_pct\_utilization\_hourly, min\_pct\_utilization\_hourly, and 17 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **CustomSync** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Verge Sense platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Verge Sense platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Verge Sense system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Verge Sense system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Verge Sense API. # Webex API Source: https://docs.kodelabs.com/products/integrations/occupancy/webex Connect Webex API to KODE OS for occupancy, indoor environmental quality data > Connect Webex API to KODE OS for occupancy, indoor environmental quality data integration ## Overview Use this integration to connect Webex workspace devices to KODE OS. You can discover room and sensor assets, collect snapshot occupancy plus air quality, temperature, and sound readings on a schedule, and use webhooks or hybrid collection where your deployment supports it. | Property | Value | | - | - | | **System Type** | Occupancy, Indoor Environmental Quality | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Webex API](https://kodelabs.com/integration/webex-by-cisco/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with Webex API and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Webex API developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Webex API developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Webex API platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Webex API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Conditional | text | The base URL or IP address of the external system | | **Client ID** | Conditional | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Conditional | password | The OAuth client secret from the vendor's developer portal | | **User Key** | Conditional | password | The user-specific key from the vendor platform | | **Redirect URI** | Conditional | text | The OAuth redirect URI configured in the vendor portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **Temperature Unit** | No | dropdown | The preferred temperature unit | | **File** | Conditional | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Webex API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Webex API, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `temperature` | Current temperature reading | -- | No | `zone_air_temperature_sensor` | Webhook | | 2 | `soundLevel` | Ambient sound level (dB) | decibels | No | -- | Webhook | | 3 | `ambientNoise` | Ambient sound level (dB) | decibels | No | `noise_sensor` | Webhook | | 4 | `humidity` | Relative humidity level (%RH) | %RH | No | `zone_air_humidity_sensor` | Webhook | | 5 | `peopleCount` | Number of people currently detected in the space | -- | No | `occupancy_count` | Webhook | | 6 | `occupied` | **Yes** -- space is currently occupied / **No** -- space is not occupied | -- | No | `occupancy_status` | Webhook | | 7 | `airQuality` | Composite air quality index | -- | No | `voc_concentration_detection_sensor` | Webhook | | 8 | `standbyState` | Device connectivity status | -- | No | `connection_status` | Webhook | | 9 | `connectionStatus` | Device connectivity status | -- | No | -- | Webhook | ## What Data You Get ### Point History Time-series readings including temperature, soundLevel, ambientNoise, humidity, peopleCount, occupied, airQuality, standbyState, and 1 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions * Monitor air quality metrics (CO2, VOC, humidity, temperature) across all occupied spaces ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Webex developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Webex platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Webex system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Webex system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Webex API. # WiFi Occupancy (IMF) Source: https://docs.kodelabs.com/products/integrations/occupancy/wifi Connect WiFi Occupancy (IMF) to KODE OS for occupancy data > Connect WiFi Occupancy (IMF) to KODE OS for occupancy data integration ## Overview Use this integration to connect Wi‑Fi occupancy (IMF) to KODE OS. You can discover the scoped network assets the API exposes, then pull historical connected-device counts across Staffnet and Guest networks to estimate staff versus visitor presence. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * Network access to the WiFi Occupancy (IMF) controller or device * The IP address and port of the on-site system * Login credentials for the WiFi Occupancy (IMF) system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **WiFi Occupancy (IMF)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **IP Address** | Yes | text | The IP address of the on-site controller or device | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Read Path** | Yes | text | The path for reading data from the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the WiFi Occupancy (IMF) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the WiFi Occupancy (IMF) controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the WiFi Occupancy (IMF) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the WiFi Occupancy (IMF) API. # Xandar Source: https://docs.kodelabs.com/products/integrations/occupancy/xandar Connect Xandar to KODE OS for occupancy data > Connect Xandar to KODE OS for occupancy data integration ## Overview Use this integration to connect Xandar Kardian radar-based sensing to KODE OS. You can discover radar devices, poll snapshot occupancy and motion context on a schedule, and enable webhooks for lower-latency presence updates in smart-building use cases. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Xandar](https://kodelabs.com/integration/xandar-kardian/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Xandar and access to their API or developer portal * API key or token from the Xandar platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Xandar platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Xandar platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Xandar** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Xandar system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Xandar, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Unoccupied` | **True** -- space is unoccupied / **False** -- space is currently in use | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including Unoccupied, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Xandar platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Xandar platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Xandar system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Xandar system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Xandar API. # Xysense Source: https://docs.kodelabs.com/products/integrations/occupancy/xySense Connect Xysense to KODE OS for occupancy data > Connect Xysense to KODE OS for occupancy data integration ## Overview Use this integration to connect XY Sense area and entry sensors to KODE OS. You can discover coverage zones and devices, collect snapshot occupancy on your polling interval, and subscribe to webhooks so live space state stays current for utilization and capacity planning. | Property | Value | | - | - | | **System Type** | Occupancy | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Xysense](https://kodelabs.com/integration/xysense/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites To integrate with the XY Sense API, ensure you have the following details: * An active account in [https://app.xysense.io](https://app.xysense.io) with the appropriate access permissions. * Valid username and password credentials for the XY Sense platform. ## Generate API Credentials * Log in to the app.xysense.io using your username and password. * Navigate to Settings → API Keys. * Click Create Key. * In the dialog: * Enter a description for the key. * Select the Customer. * Choose the required permissions. * Click Create. * Copy the API Key and API Secret Key from the window and store them securely. * The API Key is generated as a combination of the description and the selected Customer. * Note: Once this window is closed, the Secret Key cannot be retrieved again. After completing the steps above, your API Key and API Secret Key will be used in the next step. ## Configure Webhook Fields marked with an asterisk \* are mandatory for completing the integration. * Provide a name, select the Customer, and choose the Type (e.g., Occupancy Changes). * Enter [integrations@kodelabs.com](mailto:integrations@kodelabs.com) in the Email field. * Under Additional Headers, add: * Key: Authorization * Value: (obtain from [integrations@kodelabs.com](mailto:integrations@kodelabs.com)) * Max Batch Delay (ms): 2000 * Max Batch Size: 500 * Enabled: true ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Xysense** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Secret Key** | Yes | password | The secret key for API authentication | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Xysense system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Xysense, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `status` | **True** -- active / **False** -- inactive | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including status, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Track real-time space utilization rates across floors and zones * Optimize HVAC and lighting schedules based on actual occupancy patterns * Generate utilization reports to inform space planning and real estate decisions ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Xysense platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Xysense platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Xysense system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Xysense system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Xysense API. # Bosch Home Connect Source: https://docs.kodelabs.com/products/integrations/other/boschHomeConnect Connect Bosch Home Connect to KODE OS for other data > Connect Bosch Home Connect to KODE OS for other data integration ## Overview Use this integration to connect Bosch Home Connect appliances to KODE OS. You discover compatible devices and collect appliance status and sensor points over REST. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Bosch Home Connect](https://kodelabs.com/integration/home-connect/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Bosch Home Connect and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Bosch Home Connect developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Bosch Home Connect developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Bosch Home Connect** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **User Key** | Yes | password | The user-specific key from the vendor platform | | **Redirect URI** | Yes | text | The OAuth redirect URI configured in the vendor portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Bosch Home Connect system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Bosch Home Connect, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Inactive` | Current activation status | -- | No | Polling | | 2 | `Automatic` | **Automatic** / **Venting** / **DelayedShutOff** | -- | No | Polling | | 3 | `Low` | **Low** / **Medium** / **High** | -- | No | Polling | | 4 | `PreHeating` | **PreHeating** / **HotAir** / **HotAirEco** / **HotAirGrilling** / **TopBottomHeating** / **TopBottomHeatingEco** / **BottomHeating** / **PizzaSetting** / **SlowCook** / **IntensiveHeat** / **KeepWarm** / **PreheatOvenware** / **FrozenHeatupSpecial** / **Desiccation** / **Defrost** / **Proof** / **HotAir30Steam** / **HotAir60Steam** / **HotAir80Steam** / **HotAir100Steam** / **SabbathProgramme** | -- | No | Polling | | 5 | `Open` | **Open** / **Closed** / **Locked** | -- | No | Polling | | 6 | `Ristretto` | **Ristretto** / **Espresso** / **EspressoDoppio** / **Coffee** / **XLCoffee** / **CaffeGrande** / **EspressoMacchiato** / **Cappuccino** / **LatteMacchiato** / **CaffeLatte** / **MilkFroth** / **WarmMilk** / **KleinerBrauner** / **GrosserBrauner** / **Verlaengerter** / **VerlaengerterBraun** / **WienerMelange** / **FlatWhite** / **Cortado** / **CafeCortado** / **CafeConLeche** / **CafeAuLait** / **Doppio** / **Kaapi** / **KoffieVerkeerd** / **Galao** / **Garoto** / **Americano** / **RedEye** / **BlackEye** / **DeadEye** / **HotWater** | -- | No | Polling | | 7 | `Mild` | **Very Mild** / **Mild** / **Mild +** / **Normal** / **Normal +** / **Strong** / **Strong +** / **VeryStrong** / **VeryStrong +** / **ExtraStrong** / **DoubleShot** / **DoubleShot +** / **DoubleShot ++** / **TripleShot** / **TripleShot +** / **CoffeeGround** | -- | No | Polling | | 8 | `Right` | **Right** / **Left** | -- | No | Polling | | 9 | `Normal` | **Normal** / **Intense** / **IntensePlus** | -- | No | Polling | | 10 | `Max` | **50C** / **55C** / **60C** / **65C** / **70C** / **75C** / **80C** / **85C** / **90C** / **95C** / **97C** / **122F** / **131F** / **140F** / **149F** / **158F** / **167F** / **176F** / **185F** / **194F** / **203F** / **Max** | -- | No | Polling | | 11 | `PreRinse` | **PreRinse** / **Auto1** / **Auto2** / **Auto3** / **Eco50** / **Quick45** / **Intensiv70** / **Normal65** / **Glas40** / **GlassCare** / **NightWash** / **Quick65** / **Normal45** / **Intensiv45** / **AutoHalfLoad** / **IntensivPower** / **MagicDaily** / **Super60** / **Kurz60** / **ExpressSparkle65** / **MachineCare** / **SteamFresh** / **MaximumCleaning** / **MixedLoad** | -- | No | Polling | | 12 | `Cotton` | **Cotton** / **Eco4060** / **Mix** / **EasyCare** / **60** / **90** | -- | No | Polling | | 13 | `Cold` | **Cold** / **GC20** / **GC30** / **GC40** / **GC50** / **GC60** / **GC70** / **GC80** / **GC90** / **Warm** / **Hot** / **Extra Hot** | -- | No | Polling | | 14 | `Off` | **Off** / **RPM400** / **RPM600** / **RPM800** / **RPM1000** / **RPM1200** / **RPM1400** / **RPM1600** / **Low** / **Medium** / **High** | -- | No | Polling | | 15 | `CleanAll` | **CleanAll** / **CleanMap** / **GoHome** | -- | No | Polling | | 16 | `TempMap` | **TempMap** / **Map1** / **Map2** / **Map3** | -- | No | Polling | | 17 | `Silent` | **Silent** / **Standard** / **Power** | -- | No | Polling | | 18 | `Discharging` | **Discharging** / **Charging** | -- | No | Polling | | 19 | `Disconnected` | **Connected** -- device is communicating normally / **Disconnected** -- device is not reachable | -- | No | Polling | | 20 | `Disabled` | Whether the device is disabled | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Inactive, Automatic, Low, PreHeating, Open, Ristretto, Mild, Right, and 12 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Bosch Home Connect data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Bosch Home Connect developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Bosch Home Connect system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Bosch Home Connect API. # Cisco RoomOS Source: https://docs.kodelabs.com/products/integrations/other/ciscoRoomOS Connect Cisco RoomOS to KODE OS for other data > Connect Cisco RoomOS to KODE OS for other data integration ## Overview Use this integration to connect Cisco RoomOS collaboration endpoints to KODE OS. You discover room systems and poll meeting-room device status and telemetry for workspace operations. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Cisco RoomOS](https://kodelabs.com/integration/webex-by-cisco/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Cisco RoomOS and access to their API or developer portal * Username and password credentials for the Cisco RoomOS system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Cisco RoomOS** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Cisco RoomOS system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Cisco RoomOS, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `status` | Current operating status | -- | No | Polling | | 2 | `air_quality_index` | Composite air quality index | -- | No | Polling | | 3 | `ambient_temperature` | Current temperature reading (°C) | °C | No | Polling | | 4 | `relative_humidity` | Relative humidity level (%RH) | %RH | No | Polling | | 5 | `microphone_%s_connection_status` | Device connectivity status | -- | No | Polling | | 6 | `microphone_%s_ec_reference_delay` | Microphone echo cancellation reference delay | -- | No | Polling | | 7 | `microphone_%s_mute` | Microphone mute state | -- | No | Polling | | 8 | `ethernet_%s_mute` | Ethernet audio input mute state | -- | No | Polling | | 9 | `ethernet_%s_packet_lost` | Ethernet packets lost count | -- | No | Polling | | 10 | `ethernet_%s_packet_received` | Ethernet packets received count | -- | No | Polling | | 11 | `hdmi_%s_mute` | HDMI audio input mute state | -- | No | Polling | | 12 | `usbc_%s_mute` | USB-C audio input mute state | -- | No | Polling | | 13 | `connector_%s_%s_connected` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 14 | `connector_%s_%s_hdcp_state` | HDCP content protection state | -- | No | Polling | | 15 | `webcam_mode` | Current webcam operating mode | -- | No | Polling | | 16 | `webcam_status` | Webcam operating status | -- | No | Polling | | 17 | `availability_status` | Room availability status | -- | No | Polling | | 18 | `volume` | Total volume measured | % | No | Polling | | 19 | `volume_mute` | Volume mute state | -- | No | Polling | | 20 | `ultrasound_volume` | Ambient sound level | -- | No | Polling | | 21 | `people_count_capacity` | Number of people currently detected in the space | -- | No | Polling | | 22 | `people_count_current` | Number of people currently detected in the space | -- | No | Polling | | 23 | `people_presence` | People presence detection status | -- | No | Polling | | 24 | `room_in_use` | Whether the room is currently in use | -- | No | Polling | | 25 | `t3alarm_detected` | **True** -- t3alarm\_detected is active / **False** -- t3alarm\_detected is not active | -- | No | Polling | | 26 | `ultrasound_presence` | Ambient sound level | -- | No | Polling | | 27 | `presentation_mode` | Active presentation sharing mode | -- | No | Polling | | 28 | `hdmi_%s_mode` | HDMI input mode | -- | No | Polling | | 29 | `hdmi_%s_delay_ms` | HDMI audio delay (ms) | -- | No | Polling | | 30 | `line_%s_connection_status` | Device connectivity status | -- | No | Polling | | 31 | `line_%s_delay_ms` | Line audio delay (ms) | -- | No | Polling | | 32 | `measured_hdmi_arc_delay` | Measured HDMI ARC audio delay (ms) | -- | No | Polling | | 33 | `measured_hdmi_delay` | Measured HDMI signal delay (ms) | -- | No | Polling | | 34 | `reported_hdmi_cec_delay` | HDMI CEC reported delay (ms) | -- | No | Polling | | 35 | `availability` | Room availability indicator | -- | No | Polling | | 36 | `presenter_detected` | **True** -- presenter\_detected is active / **False** -- presenter\_detected is not active | -- | No | Polling | | 37 | `music_mode` | Music playback mode | -- | No | Polling | | 38 | `mute` | Audio mute state | -- | No | Polling | | 39 | `noise_removal` | Ambient sound level | -- | No | Polling | | 40 | `level` | Current level value | -- | No | Polling | | 41 | `state` | Current operating state | -- | No | Polling | | 42 | `connector_%s_%s_signal_state` | Video signal detection state | -- | No | Polling | | 43 | `airplay_status` | AirPlay connection status | -- | No | Polling | | 44 | `main_video_mute` | Main video output mute state | -- | No | Polling | | 45 | `main_video_source` | Active video input source | -- | No | Polling | | 46 | `active_connector` | Currently active input connector ID | -- | No | Polling | | 47 | `background_mode` | Virtual background mode | -- | No | Polling | | 48 | `frames_availability` | Frames feature availability | -- | No | Polling | | 49 | `frames_status` | Frames feature status | -- | No | Polling | | 50 | `fullscreen_mode` | Fullscreen display mode | -- | No | Polling | | 51 | `mode` | Current operating mode | -- | No | Polling | | 52 | `on_monitor_role` | Monitor role assignment | -- | No | Polling | | 53 | `connected` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 54 | `detected_connector` | Detected input connector ID | -- | No | Polling | | 55 | `flip` | Video flip/mirror state | -- | No | Polling | | 56 | `lighting_conditions` | Ambient lighting conditions assessment | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including status, air\_quality\_index, ambient\_temperature, relative\_humidity, microphone\_%s\_connection\_status, microphone\_%s\_ec\_reference\_delay, microphone\_%s\_mute, ethernet\_%s\_mute, and 48 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Cisco RoomOS data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Cisco RoomOS system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Cisco RoomOS system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Cisco RoomOS API. # Disruptive Technologies API Source: https://docs.kodelabs.com/products/integrations/other/disruptiveTechnologies Connect Disruptive Technologies API to KODE OS for other data > Connect Disruptive Technologies API to KODE OS for other data integration ## Overview Use this integration to stream Disruptive Technologies wireless sensor data into KODE OS. Webhook push covers desk, motion, door, and occupancy metrics for utilization and space planning. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Disruptive Technologies API](https://kodelabs.com/integration/disruptive-technologies/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites To integrate with the Disruptive Technologies API, ensure you have the following details: * An Environment setup in [https://studio.disruptive-technologies.com/](https://studio.disruptive-technologies.com/) ## Generate API Credentials * Get the Project ID * Navigate to Project Settings and copy the Project ID for future use. * Service Account Details * When creating a Service Account, note down: * Service Account Email * Service Account ID * Your Service Account requires Active Keys to communicate with the API. * Manually add a key by selecting Create New. * Upon creation, you will receive: * Key ID (auto-generated) * Key Secret (auto-generated) * These credentials will be used in your connector configuration. ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Disruptive Technologies API platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Disruptive Technologies API** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Disruptive Technologies API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `cellular_status_signal_strength` | cellular status signal strength | | `rssi` | rssi | | `battery_percentage` | battery percentage | | `temperature` | temperature | | `relative_humidity` | relative humidity | | `ppm` | ppm | | `pressure` | pressure | | `desk_occupancy` | desk occupancy | | `motion_detect` | motion detect | | `object_present_count` | object present count | | `total_touch_count` | total touch count | | `water_present` | water present | | `status` | status | | `DisruptiveTechnologiesStatusLastValue:` | DisruptiveTechnologiesStatusLastValue: | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Disruptive Technologies API data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Disruptive Technologies platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Disruptive Technologies platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Disruptive Technologies system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Disruptive Technologies system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Disruptive Technologies API. # Ecobee Source: https://docs.kodelabs.com/products/integrations/other/ecobee Connect Ecobee to KODE OS for other data > Connect Ecobee to KODE OS for other data integration ## Overview Use this integration to connect Ecobee smart thermostats to KODE OS through the SmartBuildings API. You discover thermostats, collect temperature and HVAC data, and manage heating and cooling schedules from the platform. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Schedules** | Supported | See [Ecobee](https://kodelabs.com/integration/ecobee/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Discover Schedules * Update Schedules ## Prerequisites * An active account with Ecobee and access to their API or developer portal * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [ecobee SmartBuildings authentication](https://docs.sb.ecobee.com/docs/authentication-guide) * [ecobee developer portal](https://www.ecobee.com/developers/) ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Ecobee** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Ecobee system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Ecobee, KODE OS maps them to the following device types and data points: ### Thermostat / FCU Canonical Type: `fcu` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `desiredHeat` | Desired heating temperature setpoint | -- | Yes | -- | Polling | | 2 | `desiredCool` | Desired cooling temperature setpoint | -- | Yes | -- | Polling | | 3 | `comfortSetting` | Current comfort profile setting | -- | No | -- | Polling | | 4 | `desiredCoolRangeMin` | Minimum allowed cooling setpoint | -- | Yes | -- | Polling | | 5 | `desiredCoolRangeMax` | Maximum allowed cooling setpoint | -- | Yes | -- | Polling | | 6 | `desiredDehumidity` | Relative humidity level (humidity) | humidity | No | -- | Polling | | 7 | `desiredHeatRangeMin` | Minimum allowed heating setpoint | -- | Yes | -- | Polling | | 8 | `desiredHeatRangeMax` | Maximum allowed heating setpoint | -- | Yes | -- | Polling | | 9 | `desiredHumidity` | Relative humidity level (humidity) | humidity | No | -- | Polling | | 10 | `Off` | **True** -- Off is active / **False** -- Off is not active | -- | No | `discharge_fan_command` | Polling | | 11 | `resumeSchedulesCommand` | Command to resume scheduled programming | -- | Yes | -- | Polling | | 12 | `temperatureHold` | Current temperature reading | -- | No | -- | Polling | | 13 | `%s:comfortSettingName` | Name of the comfort profile | -- | Yes | -- | Polling | | 14 | `%s:comfortSettingCoolFan` | Fan mode for cooling in this comfort profile | -- | Yes | -- | Polling | | 15 | `%s:comfortSettingHeatFan` | Fan mode for heating in this comfort profile | -- | Yes | -- | Polling | | 16 | `%s:comfortSettingDesiredCool` | Desired cooling temperature setpoint | -- | Yes | -- | Polling | | 17 | `%s:comfortSettingDesiredHeat` | Desired heating temperature setpoint | -- | Yes | -- | Polling | ## What Data You Get ### Point History Time-series readings including desiredHeat, desiredCool, comfortSetting, desiredCoolRangeMin, desiredCoolRangeMax, desiredDehumidity, desiredHeatRangeMin, desiredHeatRangeMax, and 9 more, collected at regular intervals from connected devices ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 15 minutes) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Ecobee system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Centralize Ecobee data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Ecobee platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Ecobee system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Ecobee API. # Enersponse Source: https://docs.kodelabs.com/products/integrations/other/enersponse Connect Enersponse to KODE OS for other data > Connect Enersponse to KODE OS for other data integration ## Overview Use this integration to connect Enersponse demand response and energy data to KODE OS. Historical REST collection brings usage signals, events, and performance metrics into the platform for energy programs. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Enersponse](https://kodelabs.com/integration/enersponse/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Enersponse and access to their API or developer portal * Username and password credentials for the Enersponse system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Enersponse** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | ## What Data You Get ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Enersponse data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `eventId` | -- | | **status** | `eventStatus` | -- | | **location** | `site.siteAddress` | transformed | | **createdAt** | `eventStartDateTimeMillis` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **EventLog** -- Default polling: 5 minutes (min: 5 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Enersponse data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Enersponse system. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Enersponse API. # JLL OneView Source: https://docs.kodelabs.com/products/integrations/other/jllOneview Connect JLL OneView to KODE OS for other data > Connect JLL OneView to KODE OS for other data integration ## Overview Use this integration to connect JLL OneView portfolio data to KODE OS. Historical REST feeds deliver asset performance, occupancy, leasing, and operational KPIs for real estate analytics. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [JLL OneView](https://kodelabs.com/integration/jll/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with JLL OneView and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the JLL OneView developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the JLL OneView developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **JLL OneView** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **User Key** | Yes | text | The user-specific key from the vendor platform | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Building Reference ID** | Yes | text | The building reference identifier in the external system | | **Subscription Key** | Yes | password | The subscription key for the vendor's API | ## What Data You Get ### Leases Lease records including tenant, space, lease terms, dates, and financial details ### Lease Costs Lease cost and billing records including charges, payment schedules, and cost breakdowns ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps JLL OneView data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | `id` | -- | | **name** | `eventType` | -- | | **status** | `actionStatus` | -- | | **createdAt** | `createdOn` | transformed | | **updatedAt** | `updatedOn` | transformed | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Lease** -- Default polling: 7 days (min: 7 days, max: 7 days) * **LeaseCost** * **EventLog** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize JLL OneView data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the JLL OneView developer portal. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the JLL OneView API. # KODE MQTT Source: https://docs.kodelabs.com/products/integrations/other/kodeMqtt Connect KODE MQTT to KODE OS for other data > Connect KODE MQTT to KODE OS for other data integration ## Overview Use this integration to publish and subscribe to MQTT topics through KODE OS. You map devices from broker metadata topics, collect delta sensor streams, and use schedules and actions where your broker and topic layout allow. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | MQTT | | **Collection** | Push | | **Collection Mode** | DELTA | | **Schedules** | Supported | | **Actions** | Supported | See [KODE MQTT](https://kodelabs.com/integration/kode/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Discover Schedules * Create Schedules * Update Schedules * Delete Schedules ## Prerequisites * Access to the MQTT broker used by KODE MQTT * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Broker credentials 1. Log in to the MQTT broker admin console or identity provider used by KODE MQTT 2. Create or locate a broker user with subscribe (and publish, if actions or schedules are required) permissions 3. Note the username, password, and any TLS certificate material 4. Store these values securely -- you will need them when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **KODE MQTT** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The MQTT broker hostname or URL | | **API Key** | Yes | password | The broker credential or API key used to authenticate the MQTT client | | **Metadata Topic** | Yes | text | The MQTT topic for device metadata | | **Telemetry Topic** | Yes | text | The MQTT topic for telemetry data | | **Command Topic** | Yes | text | The MQTT topic for sending commands to devices | | **Schedule Configuration Topic** | No | text | The MQTT topic for schedule configuration messages | | **Schedule State Topic** | Conditional | text | The MQTT topic for schedule state messages | | **Schedule Command Topic** | Conditional | text | The MQTT topic for schedule command messages | | **Response Command Topic** | Conditional | text | The MQTT topic for command response messages | ## Device and point mapping MQTT connectors usually receive data as it arrives and often do not use a REST-style discovery step. Configure the metadata and telemetry topics so KODE OS can map devices from published messages. If your deployment exposes a Discover action, review mapped devices and register the ones you want in KODE OS. For more details on discovery behavior by protocol, see the [Discovery guide](/products/integrations/capabilities/discovery) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Schedule Sync Schedule state synchronization data between KODE OS and the external system's controller schedules ### Schedule Sync (Partial) Partial schedule synchronization for incremental schedule updates ### Polling Schedule * **Point History** -- Default interval: 30 seconds (min: 30 seconds, max: 10 minutes) MQTT delivers telemetry as messages arrive. Interval values apply only if a pull fallback is configured for your deployment. For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions This integration supports actions that allow you to send commands to the KODE MQTT system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS publishes the action to the configured command topic using the MQTT client credentials * Devices or services subscribed to that topic process the command and may reply on the response topic For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Schedule Management This integration supports discovering and managing schedules in the KODE MQTT system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Centralize KODE MQTT data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the KODE MQTT devices. Ensure the MQTT client has subscribe permissions. > [accordion] Discovery returns no devices > > Confirm the metadata topic matches what devices publish and that the MQTT client has subscribe permissions on that topic. MQTT connectors often map devices from metadata messages rather than querying a REST catalog. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired broker credentials, network changes, or broker ACL restrictions. # Logic One API Source: https://docs.kodelabs.com/products/integrations/other/logicOne Connect Logic One API to KODE OS for other data > Connect Logic One API to KODE OS for other data integration ## Overview Use this integration to bridge Logic One REST APIs to BACnet-oriented data in KODE OS. You discover devices, poll points, apply schedules, and sync non-sensor metadata for connected networks. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Schedules** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Schedules Support (from enum) ## Prerequisites * An active account with Logic One API and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Logic One API developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Logic One API developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Logic One API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Site ID** | Yes | text | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Logic One API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `zone_temperature` | zone temperature | | `fan_status` | fan status | | `heat_anticipator` | heat anticipator | | `control_setpoint_h` | control setpoint h | | `heat_2` | heat 2 | | `limit_status` | limit status | | `scheduled_status` | scheduled status | | `control_setpoint_c` | control setpoint c | | `output_status` | output status | | `setpoint` | setpoint | | `system_humidity` | system humidity | | `cool_setback` | cool setback | | `cool_1` | cool 1 | | `cool_1_2_delay` | cool 1 2 delay | | `cool_anticipator` | cool anticipator | | `load_status` | load status | | `override_status` | override status | | `fan` | fan | | `heat_1` | heat 1 | | `heat_3` | heat 3 | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Building Alarms Building management system alarms from the Logic One platform ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **LogicOneAlarm** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Schedule Management This integration supports discovering and managing schedules in the Logic One API system. You can discover existing schedules, create new ones, and sync schedule states between KODE OS and the external system. For more details, see the [Schedules guide](/products/integrations/capabilities/schedules). ## Use Cases Once connected, this integration enables you to: * Centralize Logic One API data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Logic One developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Logic One system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Logic One API. # Nalco Source: https://docs.kodelabs.com/products/integrations/other/nalcoapi Connect Nalco to KODE OS for other data > Connect Nalco to KODE OS for other data integration ## Overview Use this integration to connect Nalco water treatment analytics to KODE OS. You discover assets, collect sensor readings, and pull historical water-management data over REST. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites * An active account with Nalco and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Nalco developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Nalco developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Nalco** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Site ID** | Yes | text | The site identifier in the external system | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Service Account Email** | Yes | text | The service account email for authentication | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Tenant ID** | Yes | text | The tenant identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Nalco system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Nalco data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Nalco developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Nalco system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Nalco API. # Q SYS Reflect Source: https://docs.kodelabs.com/products/integrations/other/qSys Connect Q SYS Reflect to KODE OS for other data > Connect Q SYS Reflect to KODE OS for other data integration ## Overview Use this integration to connect Q-SYS Reflect enterprise AV systems to KODE OS. You discover Q-SYS devices and collect health and operational telemetry for multi-site audio and video estates. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Q SYS Reflect](https://kodelabs.com/integration/q-sys-reflect/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Q SYS Reflect and access to their API or developer portal * API key or token from the Q SYS Reflect platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Q SYS Reflect platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Q SYS Reflect** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Q SYS Reflect system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Q SYS Reflect, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Offline` | **True** -- Offline is active / **False** -- Offline is not active | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Offline, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) * **EventLog** * **Audit Log** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Q SYS Reflect data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Q SYS Reflect platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Q SYS Reflect system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Q SYS Reflect API. # Zone Works (ELS) Source: https://docs.kodelabs.com/products/integrations/other/zoneWorks Connect Zone Works (ELS) to KODE OS for other data > Connect Zone Works (ELS) to KODE OS for other data integration ## Overview Use this integration to connect Zone Works emergency lighting to KODE OS over TCP/IP. You discover fixtures, collect lamp and circuit status, and ingest compliance-related records for life-safety visibility. | Property | Value | | - | - | | **System Type** | Other | | **Communication** | TCP/IP | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Zone Works (ELS)](https://kodelabs.com/integration/zoneworks-hive/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * Network access to the Zone Works (ELS) controller or device * The IP address and port of the on-site system * Login credentials for the Zone Works (ELS) system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Zone Works (ELS)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Host** | Yes | text | The host address for the connection | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Database Name** | Yes | text | The database name to connect to | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Zone Works (ELS) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Zone Works (ELS), KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | **True** -- active / **False** -- inactive | -- | No | Polling | | 2 | `Fault Reason` | Reason for the reported fault | -- | No | Polling | | 3 | `Lamp State` | Current state of the lamp | -- | No | Polling | | 4 | `Battery State` | Current battery condition | -- | No | Polling | | 5 | `Comm Status` | Communication link status | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, Fault Reason, Lamp State, Battery State, Comm Status, collected at regular intervals from connected devices ### Device Data Device operational data including status, metrics, and configuration state ### Gateway Data IoT gateway operational data including connectivity status and device aggregation ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Zone Works (ELS) data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Cannot connect to controller > > Verify the IP address and port are correct. Ensure the Zone Works (ELS) controller is powered on and connected to the network. Check that firewalls allow inbound connections on the configured port from the KODE OS server. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Zone Works (ELS) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Zone Works (ELS) API. # Bosch AQ Source: https://docs.kodelabs.com/products/integrations/outdoor-air-quality/boschAQI Connect Bosch AQ to KODE OS for outdoor environmental quality data > Connect Bosch AQ to KODE OS for outdoor environmental quality data integration ## Overview Use this integration to connect Bosch outdoor air quality monitors to KODE OS. You discover stations and collect historical pollutant and environmental readings over REST. | Property | Value | | - | - | | **System Type** | Outdoor Environmental Quality | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Bosch AQ](https://kodelabs.com/integration/aeroqual/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Bosch AQ and access to their API or developer portal * Username and password credentials for the Bosch AQ system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Bosch AQ** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Project ID** | Yes | password | The project identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Bosch AQ system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Bosch AQ, KODE OS maps them to the following device types and data points: ### Air Quality Sensor Canonical Type: `airQuality` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Wind_speed` | Wind speed | -- | No | `wind_linear_velocity_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including Wind\_speed, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Bosch AQ data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Bosch AQ system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Bosch AQ system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Bosch AQ API. # Aeroqual Source: https://docs.kodelabs.com/products/integrations/outdoor-air-quality/specto Connect Aeroqual to KODE OS for outdoor environmental quality, weather data > Connect Aeroqual to KODE OS for outdoor environmental quality, weather data integration ## Overview Use this integration to connect Aeroqual outdoor air and weather monitors to KODE OS. You discover devices and pull measurement history for air quality and meteorological metrics over REST. | Property | Value | | - | - | | **System Type** | Outdoor Environmental Quality, Weather Data | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites To connect to the Specto API, there are two supported methods: * Cloud API – connects via the Aeroqual Cloud platform * Local API – connects directly through your local network You only need one of the following sets of credentials, depending on which method you choose: Cloud API * An active account at [https://cloud.aeroqual.com](https://cloud.aeroqual.com) with the appropriate access permissions. * Valid username and password credentials for the Aeroqual platform. Local API * A valid proxy IP address provided by your local building engineer * A valid username and password to authenticate with the local network Password\* API Organization ID\* Generated in Step 2 Fields marked with an asterisk \* are mandatory for completing the integration. ## Generate API Credentials Cloud API * Log in to the Aeroqual platform at [https://cloud.aeroqual.com](https://cloud.aeroqual.com) using your username and password. * From the top menu, select Dashboards. * On the left side of the screen, you’ll see a list of organizations. * Your API Organization ID is the name/title of the listed organization (e.g., KODE Laboratories Inc). Local API ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Aeroqual** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Version** | Yes | dropdown | The API or firmware version to use | | **Organization ID** | Conditional | text | The organization ID in the vendor's API | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Aeroqual system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Incorporate external weather conditions into building optimization models * Correlate energy consumption with outdoor temperature and humidity trends ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Aeroqual system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Aeroqual system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Aeroqual API. # Flash Parking Source: https://docs.kodelabs.com/products/integrations/parking/flashParking Connect Flash Parking to KODE OS for parking data > Connect Flash Parking to KODE OS for parking data integration ## Overview Use this integration to connect Flash Parking to KODE OS. REST and webhooks deliver real-time ticket data, capacity counts, and availability across transient, monthly, and overall garage views for your locations. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Flash Parking](https://kodelabs.com/integration/flash-parking/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Flash Parking and access to their API or developer portal * Username and password credentials for the Flash Parking system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Flash Parking platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Flash Parking** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Location IDs** | Yes | text | Comma-separated list of location identifiers to monitor | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Flash Parking system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Flash Parking, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Logical Zone Capacity Count` | Cumulative count of events | count | No | `logical_zone_capacity_count` | Webhook | | 2 | `Occupied Count` | Cumulative count of events | count | No | `occupied_count` | Webhook | | 3 | `Available Overall` | Total available parking spaces across all categories | count | No | `available_overall` | Webhook | | 4 | `Transient Available` | Number of available transient/short-term spaces | count | No | `transient_available` | Webhook | | 5 | `Monthly Available` | Number of available monthly/long-term spaces | count | No | `monthly_available` | Webhook | | 6 | `Garage Status` | **Open** / **Closed** / **Full** | -- | No | `garage_status` | Webhook | ## What Data You Get ### Point History Time-series readings including Logical Zone Capacity Count, Occupied Count, Available Overall, Transient Available, Monthly Available, Garage Status, collected at regular intervals from connected devices ### Parking Tickets Real-time parking ticket and transaction data including entry/exit times and rates ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) * **FlashParkingRealTime** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Flash Parking system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Flash Parking platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Flash Parking system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Flash Parking system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Flash Parking API. # JustPark Source: https://docs.kodelabs.com/products/integrations/parking/justPark Connect JustPark to KODE OS for parking, occupancy data > Connect JustPark to KODE OS for parking, occupancy data integration ## Overview Use this integration to bring JustPark parking and occupancy data into KODE OS. You discover devices and points, poll current readings, and collect historical time series over REST for operations and reporting. | Property | Value | | - | - | | **System Type** | Parking, Occupancy | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [JustPark](https://kodelabs.com/integration/justpark/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Historical Data ## Prerequisites * An active account with JustPark and access to their API or developer portal * API key or token from the JustPark platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the JustPark platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **JustPark** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | text | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the JustPark system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from JustPark, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Total` | Total count | count | No | `occupancy_count` | Polling | | 2 | `Unoccupied` | Number of currently unoccupied spaces | count | No | `total_unoccupied_count` | Polling | ## What Data You Get ### Point History Time-series readings including Total, Unoccupied, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning * Track real-time space utilization rates across floors and zones ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the JustPark platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the JustPark system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the JustPark API. # Park Assist Source: https://docs.kodelabs.com/products/integrations/parking/parkAssist Connect Park Assist to KODE OS for parking data > Connect Park Assist to KODE OS for parking data integration ## Overview Use this integration to connect Park Assist parking guidance to KODE OS. You discover zones and spaces, then poll availability, occupancy, reservations, violations, and daily visits for consolidated monitoring. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Park Assist](https://kodelabs.com/integration/park-assist/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Park Assist and access to their API or developer portal * Username and password credentials for the Park Assist system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Park Assist** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Park Assist system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Park Assist, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `available` | Number of currently available spaces | count | No | `total_unoccupied_count` | Polling | | 2 | `occupied` | Number of currently occupied spaces | count | No | `occupancy_count` | Polling | | 3 | `outOfService` | Number of spaces currently out of service | count | No | -- | Polling | | 4 | `reserved` | Number of currently reserved spaces | count | No | -- | Polling | | 5 | `total` | Total count | count | No | -- | Polling | | 6 | `vacant` | Number of vacant spaces | count | No | `max_unoccupied_count` | Polling | | 7 | `isOutOfService` | **True** -- device is out of service / **False** -- device is in service | -- | No | `occupancy_label` | Polling | | 8 | `isInViolation` | **True** -- violation detected / **False** -- no violation | -- | No | `occupancy_label` | Polling | | 9 | `isOccupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Polling | | 10 | `isReserved` | **True** -- space is reserved / **False** -- space is not reserved | -- | No | `occupancy_label` | Polling | | 11 | `visitsToday` | Number of parking visits today | count | No | -- | Polling | ## What Data You Get ### Point History Time-series readings including available, occupied, outOfService, reserved, total, vacant, isOutOfService, isInViolation, and 3 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Park Assist system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Park Assist system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Park Assist API. # ParkChamp Source: https://docs.kodelabs.com/products/integrations/parking/parkChamp Connect ParkChamp to KODE OS for parking data > Connect ParkChamp to KODE OS for parking data integration ## Overview Use this integration to ingest ParkChamp parking operations data into KODE OS. Scheduled polling brings access logs and vehicle records into the platform so you can track entries, exits, and facility utilization. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [ParkChamp](https://kodelabs.com/integration/parkchamp/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with ParkChamp and access to their API or developer portal * API key or token from the ParkChamp platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the ParkChamp platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **ParkChamp** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Devices and Points | Point | Display Name | | - | - | | `access_point` | access point | ## What Data You Get ### Parking Access Logs Parking facility access logs including vehicle entry/exit events ### Vehicles Vehicle registration and tracking data in parking facilities ### Polling Schedule * **ParkChampVehicles** -- Default polling: 2 minutes (min: 2 minutes, max: 1 days) * **ParkChampAccessLogs** -- Default polling: 2 minutes (min: 2 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the ParkChamp platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the ParkChamp API. # ParkHelp Source: https://docs.kodelabs.com/products/integrations/parking/parkHelp Connect ParkHelp to KODE OS for parking data > Connect ParkHelp to KODE OS for parking data integration ## Overview Use this integration to connect ParkHelp to KODE OS for zone-level parking metrics. You discover spaces and poll counts for available, closed, reserved, and specialized bays alongside status flags for occupancy and operations. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with ParkHelp and access to their API or developer portal * Username and password credentials for the ParkHelp system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **ParkHelp** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the ParkHelp system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from ParkHelp, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `totalSpaces` | Total number of parking spaces in the zone | count | No | `threshold_people_capacity` | Polling | | 2 | `availableSpaces` | Number of currently available parking spaces | count | No | `total_unoccupied_count` | Polling | | 3 | `closedSpaces` | Number of spaces currently closed or out of service | count | No | `unoccupied_count` | Polling | | 4 | `reservedSpaces` | Number of spaces currently reserved | count | No | `unoccupied_count` | Polling | | 5 | `nonOperativeSpaces` | Number of non-operative parking spaces | count | No | `unoccupied_count` | Polling | | 6 | `handicappedSpaces` | Count of unoccupied/non-active spaces | count | No | `max_unoccupied_count` | Polling | | 7 | `availableHandicappedSpaces` | Count of unoccupied/non-active spaces | count | No | `unoccupied_count` | Polling | | 8 | `pregnantSpaces` | Count of unoccupied/non-active spaces | count | No | `max_unoccupied_count` | Polling | | 9 | `availablePregnantSpaces` | Count of unoccupied/non-active spaces | count | No | `unoccupied_count` | Polling | | 10 | `availableEvSpaces` | Count of unoccupied/non-active spaces | count | No | `unoccupied_count` | Polling | | 11 | `familySpaces` | Count of unoccupied/non-active spaces | count | No | `max_unoccupied_count` | Polling | | 12 | `availableFamilySpaces` | Count of unoccupied/non-active spaces | count | No | `unoccupied_count` | Polling | | 13 | `availableAllTypeSpaces` | Count of unoccupied/non-active spaces | count | No | `unoccupied_count` | Polling | | 14 | `occupiedAllTypeSpaces` | Number of people currently detected in the space | count | No | `occupancy_count` | Polling | | 15 | `closed` | **True** -- condition is ongoing / **False** -- condition is not active | -- | No | `ongoing_status` | Polling | | 16 | `free` | **True** -- space is occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Polling | | 17 | `reserved` | **True** -- space is reserved / **False** -- space is not reserved | -- | No | `ongoing_status` | Polling | ## What Data You Get ### Point History Time-series readings including totalSpaces, availableSpaces, closedSpaces, reservedSpaces, nonOperativeSpaces, handicappedSpaces, availableHandicappedSpaces, pregnantSpaces, and 9 more, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the ParkHelp system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the ParkHelp system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the ParkHelp API. # Parking detection Source: https://docs.kodelabs.com/products/integrations/parking/parkingDetection Connect Parking detection to KODE OS for parking data > Connect Parking detection to KODE OS for parking data integration ## Overview Use this integration to connect your parking detection system to KODE OS. You discover sensors and collect occupancy state, duration, and operating state over REST for each monitored space. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Parking detection](https://kodelabs.com/integration/parking-detection/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Parking detection and access to their API or developer portal * API key or token from the Parking detection platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Parking detection platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Parking detection** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Parking detection system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Parking detection, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `occupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Polling | | 2 | `state` | Current operating state | -- | No | `occupancy_label` | Polling | | 3 | `duration` | Duration of the current state | -- | No | `occupancy_time_accumulator` | Polling | ## What Data You Get ### Point History Time-series readings including occupied, state, duration, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Parking detection platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Parking detection system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Parking detection API. # Precise Park Source: https://docs.kodelabs.com/products/integrations/parking/precisePark Connect Precise Park to KODE OS for parking data > Connect Precise Park to KODE OS for parking data integration ## Overview Use this integration to bring Precise Park data into KODE OS. You discover devices per building API ID, monitor space counts and violation or service flags, and ingest related non-sensor parking records. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Precise Park](https://kodelabs.com/integration/precise-park/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Precise Park and access to their API or developer portal * Username and password credentials for the Precise Park system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Precise Park** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Precise Park system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Precise Park, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `is_in_violation` | **True** -- violation detected / **False** -- no violation | -- | No | `threshold_alarm` | Polling | | 2 | `is_occupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Polling | | 3 | `is_out_of_service` | **True** -- device is out of service / **False** -- device is in service | -- | No | `ongoing_status` | Polling | | 4 | `is_reserved` | **True** -- space is reserved / **False** -- space is not reserved | -- | No | `ongoing_status` | Polling | | 5 | `available` | Number of currently available spaces | -- | No | `total_unoccupied_count` | Polling | | 6 | `occupied` | Number of currently occupied spaces | -- | No | `occupancy_count` | Polling | | 7 | `out_of_service` | Count of unoccupied/non-active spaces | -- | No | `unoccupied_count` | Polling | | 8 | `reserved` | Count of unoccupied/non-active spaces | -- | No | `unoccupied_count` | Polling | | 9 | `vacant` | Number of vacant spaces | -- | No | `max_unoccupied_count` | Polling | | 10 | `total` | Total count | -- | No | `unoccupied_count` | Polling | ## What Data You Get ### Point History Time-series readings including is\_in\_violation, is\_occupied, is\_out\_of\_service, is\_reserved, available, occupied, out\_of\_service, reserved, and 2 more, collected at regular intervals from connected devices ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique booking identifier | | **Title** | Booking title or subject | | **Description** | Booking details | | **Status** | Booking status (e.g., Confirmed, Pending, Cancelled) | | **Type** | Booking type (Room, Desk, Parking, Visitor) | | **Location** | Space or room being booked | | **Host Name** | Person who created the booking | | **Host Email** | Email of the booking host | | **Attendee Name** | Visitor or attendee name | | **Attendee Email** | Visitor or attendee email | | **Start Time** | Booking start date and time | | **End Time** | Booking end date and time | | **Check-In** | Actual check-in timestamp | | **Check-Out** | Actual check-out timestamp | | **Confirmed** | Whether the booking has been confirmed | | **Cancelled** | Whether the booking has been cancelled | | **Created At** | Timestamp when the booking was created | | **Updated At** | Timestamp of the last update | ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) * **Booking** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Precise Park system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Precise Park system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Precise Park API. # Quercus Source: https://docs.kodelabs.com/products/integrations/parking/quercus Connect Quercus to KODE OS for parking data > Connect Quercus to KODE OS for parking data integration ## Overview Use this integration to connect Quercus LPR and parking systems to KODE OS. You discover devices, poll status and sensor history, pair reservations and non-sensor data, and run configured API actions from the platform. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Quercus](https://kodelabs.com/integration/quercus/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * API Requests ## Prerequisites * An active account with Quercus and access to their API or developer portal * API key or token from the Quercus platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Quercus platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Quercus** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Quercus system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Quercus, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | **True** -- active / **False** -- inactive | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Reservations Space reservation records including booking details, attendees, and confirmation status ### Access Events Access control events from the Quercus platform including badge reads and door events ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 30 seconds) * **QuercusAccessEvent** -- Default polling: 1 days (min: 1 days, max: 1 days) * **QuercusReservation** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Quercus platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Quercus system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Quercus API. # WOHR API Source: https://docs.kodelabs.com/products/integrations/parking/wohr Connect WOHR API to KODE OS for parking data > Connect WOHR API to KODE OS for parking data integration ## Overview Use this integration to stream WOHR bike-silo data into KODE OS over MQTT. You receive bay status and assignment updates, optionally linking Avigilon ACM so permitted riders stay aligned with physical access. | Property | Value | | - | - | | **System Type** | Parking | | **Communication** | MQTT | | **Collection** | Push | | **Collection Mode** | DELTA | See [WOHR API](https://kodelabs.com/integration/wohr/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data * MQTT Data Collection ## Prerequisites * Access to the MQTT broker used by WOHR API * Broker hostname, port, and credentials * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **WOHR API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Host** | Yes | text | The host address for the connection | | **Port** | Yes | text | The port number for connecting to the system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Path** | Yes | text | The API path or resource path on the external system | | **Plant Name** | Yes | text | Configuration field for Plant Name | | **Avigilon Datasource ID** | No | text | Configuration field for Avigilon Datasource ID | ## Devices and Points When you discover devices from WOHR API, KODE OS maps them to the following device types and data points: ### Parking Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Bay Status` | Current status of the parking bay | -- | No | MQTT | | 2 | `Bay User` | User assigned to the parking bay | -- | No | MQTT | ## What Data You Get ### Point History Time-series readings including Bay Status, Bay User, collected at regular intervals from connected devices ### Polling Schedule * **Point History** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor real-time parking space availability across facilities * Track occupancy trends to optimize parking allocation and signage * Generate utilization reports for parking revenue and capacity planning ## Troubleshooting > [accordion] No data arriving from MQTT broker > > Verify the MQTT broker hostname, port, and credentials. Check that the topic patterns match the topics being published by the WOHR devices. Ensure the MQTT client has subscribe permissions. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the WOHR API. # Kahua Source: https://docs.kodelabs.com/products/integrations/project-management/kahua Connect Kahua to KODE OS for project data > Connect Kahua to KODE OS for project data integration ## Overview Use this integration to connect Kahua construction and capital project data to KODE OS. REST historical collection brings project, procurement, and execution records into the platform for portfolio alignment. | Property | Value | | - | - | | **System Type** | Project | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data ## Prerequisites * An active account with Kahua and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Kahua developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Kahua developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kahua** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## What Data You Get ### Projects Project records including project name, status, timelines, and associated documentation ### Polling Schedule * **Project** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Kahua data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Kahua developer portal. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kahua API. # CloudGate Source: https://docs.kodelabs.com/products/integrations/reservations/cloudGate Connect CloudGate to KODE OS for reservations data > Connect CloudGate to KODE OS for reservations data integration ## Overview Use this integration to connect CloudGate visitor identity and access workflows to KODE OS. REST pulls and webhooks feed reservation and visitor-related data into the platform, including where actions are enabled for your connector. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [CloudGate](https://kodelabs.com/integration/cloudgate/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with CloudGate and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the CloudGate developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the CloudGate developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the CloudGate platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **CloudGate** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Location ID** | Yes | text | The location identifier in the external system | | **Application ID** | Yes | password | The application ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Devices and Points | Point | Display Name | | - | - | | `200` | 200 | | `401` | 401 | | `LogIn` | LogIn | | `LogOut` | LogOut | ## What Data You Get ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps CloudGate data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `visitId` | -- | | **checkInDateTime** | `actionDateTimeMillis` | -- | | **checkOutDateTime** | `actionDateTimeMillis` | -- | | **createdAt** | `actionDateTimeMillis` | -- | | **createdBy** | `createdBy` | -- | | **isCanceled** | `false` | -- | | **updatedAt** | `actionDateTimeMillis` | -- | | **updatedBy** | `createdBy` | -- | | **updatedAt** | `actionDateTimeMillis` | -- | | **canceledAt** | `actionDateTimeMillis` | -- | | **updatedBy** | `updatedBy` | -- | | **isCanceled** | `true` | -- | | **checkInDateTime** | `actionDateTimeMillis` | conditional | | **checkOutDateTime** | `actionDateTimeMillis` | conditional | ### Polling Schedule * **Booking** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Booking **Type:** Write Creates a new visitor booking in CloudGate | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **Purpose** | STRING | Yes | Text Box | -- | | **Start** | DATE\_TIME | Yes | Text Box | -- | | **End** | DATE\_TIME | Yes | Text Box | -- | | **Visitor ID** | STRING | Yes | Text Box | -- | | **Visitor Name** | STRING | No | Text Box | -- | | **Email** | STRING | No | Text Box | -- | | **Phone** | STRING | No | Text Box | -- | | **Host Name** | STRING | No | Text Box | -- | | **Action DateTime** | DATE\_TIME | Yes | Text Box | -- | | **Created By** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "purpose": "example-value", "start": "2026-03-29T10:00:00Z", "end": "2026-03-29T10:00:00Z", "visitor_id": "12345", "action_datetime": "2026-03-29T10:00:00Z", "created_by": "example-value", "visitor_name": "example-value", "email": "ops@example.com" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Booking **Type:** Write Updates an existing visitor booking in CloudGate | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **Purpose** | STRING | Yes | Text Box | -- | | **Start** | DATE\_TIME | Yes | Text Box | -- | | **End** | DATE\_TIME | Yes | Text Box | -- | | **Visitor ID** | STRING | Yes | Text Box | -- | | **Updated By** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "purpose": "example-value", "start": "2026-03-29T10:00:00Z", "end": "2026-03-29T10:00:00Z", "visitor_id": "12345", "updated_by": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Cancel Booking **Type:** Write Cancels an existing visitor booking in CloudGate | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **Action DateTime** | DATE\_TIME | Yes | Text Box | -- | | **Updated By** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "action_datetime": "2026-03-29T10:00:00Z", "updated_by": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Mark Attendance **Type:** Write Records check-in/check-out for a visitor booking | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Order Number** | STRING | Yes | Text Box | -- | | **Barcode** | STRING | Yes | Text Box | -- | | **Check-In Time** | DATE\_TIME | No | Text Box | -- | | **Check-Out Time** | DATE\_TIME | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "OrderNumber": "example-value", "Barcode": "example-value", "CheckInTime": "2026-03-29T10:00:00Z", "CheckOutTime": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Booking Status **Type:** Write Updates the status of a visitor booking in CloudGate | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Event** | STRING | Yes | Text Box | -- | | **Visit ID** | STRING | Yes | Text Box | -- | | **Action DateTime** | DATE\_TIME | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "event": "example-value", "visit_id": "12345", "action_datetime": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the CloudGate developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the CloudGate platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the CloudGate system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the CloudGate API. # Condeco API Source: https://docs.kodelabs.com/products/integrations/reservations/condeco Connect Condeco API to KODE OS for reservations data > Connect Condeco API to KODE OS for reservations data integration ## Overview Use this integration to bring Condeco room and desk reservations into KODE OS. Discovery, REST polling, and webhooks keep utilization, bookings, and workspace status aligned with your building operations. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | See [Condeco API](https://kodelabs.com/integration/condeco/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data * Collect Historical Data ## Prerequisites * An active account with Condeco API and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Condeco API developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Condeco API developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Condeco API platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Condeco API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Location ID** | Yes | password | The location identifier in the external system | | **External Booking Subscription Key** | Yes | password | Configuration field for External Booking Subscription Key | | **Hierarchy Mapping Subscription Key** | Yes | password | Configuration field for Hierarchy Mapping Subscription Key | | **Primary Key** | No | password | Configuration field for Primary Key | | **Non-Sensor Data Config** | Yes | dropdown | Configuration for non-sensor data collection types | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Condeco API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Condeco API, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `resource_occupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | `occupancy_status` | Webhook | ## What Data You Get ### Point History Time-series readings including resource\_occupied, collected at regular intervals from connected devices ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps Condeco API data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `bookingId` | -- | | **category** | mapped by connector | -- | | **locationId** | `floorNumber` | -- | | **locationName** | `floorName` | -- | | **startDateTime** | `startDate` | -- | | **endDateTime** | `endDate` | -- | | **createdBy** | `deskCreatorUserName` | -- | | **createdAt** | `createdOn` | -- | | **status** | mapped by connector | -- | | **attendeeId** | `deskBookedToUserID` | -- | | **attendeeName** | `deskBookedToUserName` | -- | | **attendeeEmail** | `deskBookedToUserEmail` | -- | | **attendeeCompany** | `deskBookedToUserCompany` | -- | | **attendeePhone** | `deskBookedToUserTelephone` | -- | | **customFields** | `(custom fields)` | custom fields object | | **id** | `bookingID` | -- | | **category** | mapped by connector | -- | | **title** | `meetingTitle` | -- | | **status** | mapped by connector | -- | | **locationId** | `locationId` | -- | | **locationName** | `locationName` | -- | | **hostName** | `hostName` | -- | | **hostEmail** | `hostEmail` | -- | | **attendeeId** | `requesterId` | -- | | **attendeeEmail** | `requesterEmail` | -- | | **attendeeName** | `requesterName` | -- | | **createdAt** | `createdOn` | -- | | **updatedAt** | `lastModifiedOn` | -- | | **checkInDateTime** | `bookingRealStartTime` | -- | | **checkOutDateTime** | `bookingRealEndTime` | -- | | **startDateTime** | `bookingStart` | -- | | **endDateTime** | `bookingEnd` | -- | | **createdBy** | `creatorName` | -- | | **customFields** | `(custom fields)` | custom fields object | | **id** | `(formatted)` | -- | | **category** | mapped by connector | -- | | **title** | `name` | -- | | **description** | `meetingTitle` | -- | | **status** | `approvalStatus` | -- | | **locationName** | `roomName` | -- | | **hostName** | `hostName` | -- | | **startDateTime** | mapped by connector | -- | | **endDateTime** | `pickup` | -- | | **createdBy** | `requesterName` | -- | | **hostPhone** | `hostPhone` | -- | | **hostEmail** | `hostEmail` | -- | | **attendeePhone** | `requesterPhone` | -- | | **attendeeEmail** | `requesterEmail` | -- | | **customFields** | `(custom fields)` | custom fields object | | **createdAt** | mapped by connector | -- | | **createdAt** | mapped by connector | conditional | ### Polling Schedule * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) * **Booking** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Condeco developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Condeco platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Condeco system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Condeco system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Condeco API. # Accruent Source: https://docs.kodelabs.com/products/integrations/reservations/ems Connect Accruent to KODE OS for reservations data > Connect Accruent to KODE OS for reservations data integration ## Overview Use this integration to sync Accruent EMS scheduling with KODE OS. You discover resources, collect workspace and event reservation data, and use snapshots for reporting across your portfolio. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Accruent](https://kodelabs.com/integration/accruent/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Accruent and access to their API or developer portal * Username and password credentials for the Accruent system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Accruent** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Host Name** | Yes | text | The hostname of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **Schedule Data Source ID** | No | text | The schedule data source identifier for syncing schedules | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Accruent system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Accruent, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `room_active` | **True** -- room\_active is active / **False** -- room\_active is not active | -- | No | Polling | | 2 | `room_occupied` | **True** -- space is currently occupied / **False** -- space is unoccupied | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including room\_active, room\_occupied, collected at regular intervals from connected devices ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps Accruent data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `bookingID` | -- | | **title** | `eventName` | -- | | **locationId** | `roomID` | -- | | **description** | `eventTypeDescription` | -- | | **status** | `statusID` | -- | | **category** | mapped by connector | -- | | **hasCheckedIn** | `checkedIn` | -- | | **locationName** | `roomDescription` | -- | | **startDateTime** | `gmtStartTime` | transformed | | **endDateTime** | `gmtEndTime` | transformed | | **createdAt** | mapped by connector | transformed | | **updatedAt** | mapped by connector | transformed | | **createdBy** | `addedBy` | -- | | **updatedBy** | `changedBy` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Booking** -- Default polling: 5 minutes (min: 5 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Accruent system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Accruent system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Accruent API. # Momentus Technologies Source: https://docs.kodelabs.com/products/integrations/reservations/momentus Connect Momentus Technologies to KODE OS for reservations data > Connect Momentus Technologies to KODE OS for reservations data integration ## Overview Use this integration to connect Momentus venue and event data to KODE OS. REST polling collects reservation-related sensor and operational records with historical depth for venues you manage. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Momentus Technologies and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Momentus Technologies** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **User Key** | Yes | password | The user-specific key from the vendor platform | | **API Secret Key** | Yes | password | The secret key for API authentication | | **User ID** | Yes | text | The user identifier in the external system | | **Organization ID** | Yes | text | The organization ID in the vendor's API | ## What Data You Get ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps Momentus Technologies data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `eventId` | transformed | | **title** | `description` | transformed | | **description** | `description` | transformed | | **status** | `status` | transformed | | **category** | `category` | transformed | | **isConfirmed** | `decision` | -- | | **isCanceled** | `cancelledOn` | -- | | **hasCheckedIn** | `inDate` | -- | | **hasCheckedOut** | `outDate` | -- | | **locationName** | `anchorVenue` | transformed | | **hostName** | `coordinator` | transformed | | **hostPhone** | `onSitePhone` | transformed | | **hostType** | `salesperson` | transformed | | **attendeeId** | `account` | transformed | | **attendeeName** | `legalName` | transformed | | **attendeeCompany** | `billTo` | -- | | **startDateTime** | `times.startUtc` | -- | | **endDateTime** | `times.endUtc` | -- | | **checkInDateTime** | `times.checkInUtc` | -- | | **checkOutDateTime** | `times.checkOutUtc` | -- | | **confirmDateTime** | `times.confirmUtc` | -- | | **canceledAt** | `times.cancelUtc` | -- | | **createdAt** | `times.createdUtc` | -- | | **updatedAt** | `times.updatedUtc` | -- | | **createdBy** | `enteredBy` | transformed | | **updatedBy** | `changedBy` | transformed | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **Booking** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Momentus Technologies platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Momentus Technologies API. # Outlook Source: https://docs.kodelabs.com/products/integrations/reservations/outlook Connect Outlook to KODE OS for reservations data > Connect Outlook to KODE OS for reservations data integration ## Overview Use this integration to connect Microsoft Outlook calendars and reservations to KODE OS. Hybrid pull and push collection keeps meeting and room data current where your connector supports discovery, actions, and related workflows. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Outlook](https://kodelabs.com/integration/outlook/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Outlook and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Outlook developer portal * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Microsoft Graph sendMail](https://learn.microsoft.com/en-us/graph/api/user-sendmail?view=graph-rest-1.0) * [Outlook mail API overview](https://learn.microsoft.com/en-us/graph/outlook-create-send-messages) ## Generate API Credentials 1. Log in to the Outlook developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Outlook** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Tenant ID** | Yes | text | The tenant identifier in the external system | | **User Email Address** | Yes | text | Configuration field for User Email Address | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Outlook system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Outlook, KODE OS maps them to the following device types and data points: ### Presence / Occupancy Sensor Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `status` | **True** -- active / **False** -- inactive | -- | No | `status` | Polling | ## What Data You Get ### Point History Time-series readings including status, collected at regular intervals from connected devices ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps Outlook data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **attendeeName** | derived value | transformed | | **attendeeEmail** | derived value | transformed | | **status** | derived value | transformed | ### Email Dispatch Outbound email sending capability through the integrated platform ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Booking** -- Default polling: 5 minutes (min: 5 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Send Email **Type:** Write Sends an email notification via Outlook/Microsoft 365 with pre-filled building and device context | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Send Email To** | STRING | Yes | Text Box | -- | | **Subject** | STRING | Yes | Text Box | - BMS Event from - | | **Body** | STRING | Yes | Text Area | Pre-filled template with site, time, device, point, state, priority, and direct link | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "send_email_to": "ops@example.com", "subject": "example-value", "body": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Outlook developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Outlook system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Outlook API. # Parkonect Source: https://docs.kodelabs.com/products/integrations/reservations/parkonect Connect Parkonect to KODE OS for reservations data > Connect Parkonect to KODE OS for reservations data integration ## Overview Use this integration to connect Parkonect parking reservations and payments to KODE OS. REST and webhooks deliver hybrid collection with optional actions so parking assets stay visible alongside other building data. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Parkonect](https://kodelabs.com/integration/parkonect/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Parkonect and access to their API or developer portal * Username and password credentials for the Parkonect system * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Parkonect platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Parkonect** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Vendor ID** | Yes | password | The vendor identifier in the external system | | **Garage ID** | Yes | password | The parking garage identifier | ## What Data You Get ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique booking identifier | | **Title** | Booking title or subject | | **Description** | Booking details | | **Status** | Booking status (e.g., Confirmed, Pending, Cancelled) | | **Type** | Booking type (Room, Desk, Parking, Visitor) | | **Location** | Space or room being booked | | **Host Name** | Person who created the booking | | **Host Email** | Email of the booking host | | **Attendee Name** | Visitor or attendee name | | **Attendee Email** | Visitor or attendee email | | **Start Time** | Booking start date and time | | **End Time** | Booking end date and time | | **Check-In** | Actual check-in timestamp | | **Check-Out** | Actual check-out timestamp | | **Confirmed** | Whether the booking has been confirmed | | **Cancelled** | Whether the booking has been cancelled | | **Created At** | Timestamp when the booking was created | | **Updated At** | Timestamp of the last update | ### Polling Schedule * **Booking** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Booking **Type:** Write Creates a new parking booking in Parkonect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **QR Code** | STRING | Yes | Text Box | -- | | **Start Time** | DATE\_TIME | Yes | Text Box | -- | | **End Time** | DATE\_TIME | Yes | Text Box | -- | | **Parking Space Charges** | DOUBLE | No | Number | -- | | **Visitor Name** | STRING | No | Text Box | -- | | **License Plate** | STRING | No | Text Box | -- | | **Vehicle Make** | STRING | No | Text Box | -- | | **Vehicle Model** | STRING | No | Text Box | -- | | **Vehicle Color** | STRING | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "qr_code": "example-value", "start": "2026-03-29T10:00:00Z", "end": "2026-03-29T10:00:00Z", "parking_space_charges": 1.0, "visitor_name": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Booking **Type:** Write Updates an existing parking booking in Parkonect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **QR Code** | STRING | Yes | Text Box | -- | | **Start Time** | DATE\_TIME | Yes | Text Box | -- | | **End Time** | DATE\_TIME | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "qr_code": "example-value", "start": "2026-03-29T10:00:00Z", "end": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Cancel Booking **Type:** Write Cancels a parking booking in Parkonect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Visit ID** | STRING | Yes | Text Box | -- | | **Action Date Time** | DATE\_TIME | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "visit_id": "12345", "action_datetime": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Booking Status **Type:** Write Records check-in/check-out for a parking booking | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Order Number** | STRING | Yes | Text Box | -- | | **Barcode** | STRING | Yes | Text Box | -- | | **Check-In Time** | STRING | No | Text Box | -- | | **Check-Out Time** | STRING | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "OrderNumber": "example-value", "Barcode": "example-value", "CheckInTime": "2026-03-29T10:00:00Z", "CheckOutTime": "2026-03-29T10:00:00Z" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Parkonect system. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Parkonect platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Parkonect system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Parkonect API. # TDS Visitor Management Source: https://docs.kodelabs.com/products/integrations/reservations/tds Connect TDS Visitor Management to KODE OS for reservations data > Connect TDS Visitor Management to KODE OS for reservations data integration ## Overview Use this integration to bring TDS Visitor Management into KODE OS. You collect visitor check-in, pre-registration, and scheduling history over REST for secure, auditable visitor operations. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with TDS Visitor Management and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the TDS Visitor Management developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the TDS Visitor Management developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **TDS Visitor Management** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Site ID** | Yes | text | The site identifier in the external system | ## What Data You Get ### Bookings Space reservation records including attendees, check-in/out times, confirmation status, and room/space details KODE OS maps TDS Visitor Management data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `bookingReference` | -- | | **description** | `visitReasonDescription` | -- | | **createdAt** | mapped by connector | -- | | **updatedAt** | `lastModifiedDateTimeUtc` | -- | | **createdBy** | `bookerUsername` | -- | | **locationId** | `zoneCode` | -- | | **locationName** | `zoneDescription` | -- | | **startDateTime** | `inviteDateTimeUtc` | transformed | | **endDateTime** | `endDateTimeUtc` | transformed | | **hostName** | `hostForename + " " + hostSurname` | -- | | **attendeeName** | `forename` | -- | | **attendeeEmail** | `emailAddress` | -- | | **attendeePhone** | `mobilePhoneNumber` | -- | | **attendeeCompany** | `companyCode` | -- | | **checkInDateTime** | `checkedInDateTimeUtc` | transformed | | **checkOutDateTime** | `checkedOutDateTimeUtc` | transformed | | **canceledAt** | `cancellationDateTimeUtc` | transformed | | **customFields** | `department` | -- | ### Polling Schedule * **Booking** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the TDS Visitor Management developer portal. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the TDS Visitor Management API. # Tririga - FDH Source: https://docs.kodelabs.com/products/integrations/reservations/tririgaFDH Connect Tririga - FDH to KODE OS for reservations data > Connect Tririga - FDH to KODE OS for reservations data integration ## Overview Use this integration to connect IBM Tririga FDH reservations data to KODE OS. You pull snapshot reservation and related operational records over REST for centralized monitoring and reporting. | Property | Value | | - | - | | **System Type** | Reservations | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Tririga - FDH](https://kodelabs.com/integration/tririga-fdh/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Tririga - FDH and access to their API or developer portal * API key or token from the Tririga - FDH platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Tririga - FDH platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Tririga - FDH** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **External URL** | Yes | text | An additional external URL for the integration | | **Username** | Yes | password | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Devices and Points | Point | Display Name | | - | - | | `status` | status | | `country` | country | | `collected_at` | collected at | ## What Data You Get ### Reservations Space and resource reservation records from the TRIRIGA platform ### Polling Schedule * **TririgaFDHReservations** -- Default polling: 60 minutes (min: 60 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize space and resource booking data across platforms * Track no-show rates and actual utilization versus bookings * Coordinate meeting room conditions (HVAC, lighting) with reservation schedules ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Tririga - FDH platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Tririga - FDH API. # Kolo Source: https://docs.kodelabs.com/products/integrations/smart-bathroom/kolo Connect Kolo to KODE OS for smart bathroom data > Connect Kolo to KODE OS for smart bathroom data integration ## Overview Use this integration to connect Kolo smart restroom dispensers and fixtures to KODE OS. You discover devices, monitor fill and fault points, and ingest hygiene-related records over REST. | Property | Value | | - | - | | **System Type** | Smart Bathroom | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Kolo](https://kodelabs.com/integration/kolo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Kolo and access to their API or developer portal * API key or token from the Kolo platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Kolo platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Kolo** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Kolo system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Kolo, KODE OS maps them to the following device types and data points: ### Dispenser Canonical Type: `sanitation` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `battery_level` | Device battery level (%) | % | No | Polling | | 2 | `battery_state` | Current battery condition | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including battery\_level, battery\_state, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps Kolo data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `alertId` | -- | | **location** | `deviceLocationId` | -- | | **deviceId** | mapped by connector | -- | | **status** | `alertStatus` | -- | | **description** | `alertType` | -- | | **createdAt** | `createdDate` | transformed | | **completedAt** | `resolvedDate` | transformed | | **customFields** | `(custom fields)` | -- | ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor restroom fixture usage and supply levels in real time * Dispatch cleaning crews based on actual usage data rather than fixed schedules * Track water consumption and identify fixtures requiring maintenance ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Kolo platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Kolo system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Kolo API. # Mero Source: https://docs.kodelabs.com/products/integrations/smart-bathroom/mero Connect Mero to KODE OS for smart bathroom data > Connect Mero to KODE OS for smart bathroom data integration ## Overview Use this integration to connect Mero smart restroom telemetry to KODE OS. You discover sensors and poll restroom usage and status data for cleaning and operations workflows. | Property | Value | | - | - | | **System Type** | Smart Bathroom | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Mero](https://kodelabs.com/integration/mero/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Mero and access to their API or developer portal * API key or token from the Mero platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Mero platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Mero** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Token** | Yes | text | The API token for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Mero system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Mero, KODE OS maps them to the following device types and data points: ### Dispenser Canonical Type: `sanitation` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Threshold` | Configured alert threshold | count | No | `threshold_percentage_command` | Polling | | 2 | `isLow` | **True** -- supply level is below threshold / **False** -- supply level is adequate | -- | No | `threshold_alarm` | Polling | | 3 | `Traffic` | Cumulative traffic count | count | No | `entering_counter` | Polling | ## What Data You Get ### Point History Time-series readings including Threshold, isLow, Traffic, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor restroom fixture usage and supply levels in real time * Dispatch cleaning crews based on actual usage data rather than fixed schedules * Track water consumption and identify fixtures requiring maintenance ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Mero platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Mero system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Mero API. # Tork Source: https://docs.kodelabs.com/products/integrations/smart-bathroom/tork Connect Tork to KODE OS for smart bathroom, occupancy data > Connect Tork to KODE OS for smart bathroom, occupancy data integration ## Overview Use this integration to connect Tork hygiene and occupancy endpoints to KODE OS. Webhook push and REST discovery keep dispenser and restroom sensor data synchronized for facility services. | Property | Value | | - | - | | **System Type** | Smart Bathroom, Occupancy | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [Tork](https://kodelabs.com/integration/tork/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Tork and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Tork developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Tork developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Tork platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Tork** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Connector Name** | Yes | text | Display name for this connector | | **URL** | Yes | text | Base API URL for the Tork service | | **Auth URL** | Yes | text | OAuth token endpoint URL | | **Client ID** | Yes | password | OAuth Client ID (encrypted) | | **Client Secret** | Yes | password | OAuth Client Secret (encrypted) | | **API Building ID** | Yes | password | Tork site/building identifier (encrypted) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Tork system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Tork, KODE OS maps them to the following device types and data points: ### Dispenser Canonical Type: `sanitation` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `connectivity` | **Online** -- device is connected and reporting / **Offline** -- device is not responding | -- | No | `connection_status` | Webhook | | 2 | `battery` | **Low** -- battery needs replacement / **Normal** -- battery level is healthy | -- | No | `battery_status` | Webhook | | 3 | `fillStatus` | **Green** -- dispenser does not need refilling / **Yellow** -- dispenser can be refilled / **Red** -- dispenser is almost empty | -- | No | `dispenser_refill_status` | Webhook | | 4 | `fillLevel` | Fill level as a percentage (0-100%), converted from raw scale of 0.0 to 1.0 | % | No | `tank_percentage_sensor` | Webhook | | 5 | `refillsAdded` | Number of refills added to the specific dispenser | -- | No | -- | Webhook | | 6 | `refillType` | Type of refill product (e.g., "Premium") | -- | No | -- | Webhook | ### People Counter Canonical Type: `presenceDetection` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `connectivity` | **Online** -- device is connected and reporting / **Offline** -- device is not responding | -- | No | `connection_status` | Webhook | | 2 | `battery` | **Low** -- battery needs replacement / **Normal** -- battery level is healthy | -- | No | `battery_status` | Webhook | | 3 | `totalVisitorCount` | Cumulative count of visitors detected by the sensor | -- | No | `occupancy_count` | Webhook | ## What Data You Get ### Point History Time-series sensor readings including dispenser fill levels, battery status, connectivity status, visitor counts, and refill events from Tork devices ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) > [!NOTE] > > Tork uses **webhook-based push delivery**. Data arrives in real time when device state changes. The polling schedule above is for the health-check ping interval, not for data collection. For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Receive real-time updates on dispenser refill levels, ensuring timely refills and reducing complaints about empty dispensers * Track the total number of people using the restroom per day for trend analysis and operational planning * Monitor current occupancy in restrooms, enabling more frequent cleaning for high-traffic periods * Trigger alerts if restroom occupancy exceeds predefined limits * Compare restroom usage across multiple locations to allocate resources more efficiently * Validate cleaning schedules against hygiene regulations based on actual restroom usage * Automatically trigger alarms when sensor data indicates the need for immediate attention ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the API credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values in the Tork developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Tork system to list devices. Run a test connection first to confirm connectivity. Confirm the correct Site ID is configured in the API Building ID field. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Tork platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Tork system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. For webhook integrations, verify the webhook threshold (7 days) has not been exceeded without receiving data. If the status shows an error, review the error logs on the connector detail page. # Parcel Pending Source: https://docs.kodelabs.com/products/integrations/smart-lockers/parcelPending Connect Parcel Pending to KODE OS for smart locker data > Connect Parcel Pending to KODE OS for smart locker data integration ## Overview Use this integration to connect Parcel Pending smart lockers to KODE OS. You discover lockers, poll status and metadata, and collect historical utilization data over REST. | Property | Value | | - | - | | **System Type** | Smart Locker | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Parcel Pending](https://kodelabs.com/integration/parcel-pending/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Parcel Pending and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Parcel Pending developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Parcel Pending developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Parcel Pending** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Property ID** | Yes | password | Configuration field for Property ID | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Parcel Pending system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Parcel Pending, KODE OS maps them to the following device types and data points: ### Smart Locker Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Locker Status` | Current lock state | -- | No | Polling | | 2 | `Connection Status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Locker Status, Connection Status, collected at regular intervals from connected devices ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Parcel Pending data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **category** | mapped by connector | -- | | **id** | `id` | -- | | **name** | `parcelStatus` | -- | | **status** | `status.stringValue` | transformed | | **location** | `propertyId` | -- | | **deviceId** | `lockerId` | -- | | **createdAt** | `creationTime` | -- | | **updatedAt** | `lastUpdateTime` | -- | ### Polling Schedule * **Point History** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) * **EventLog** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor locker availability and assignment status across facilities * Track parcel delivery and pickup events for tenant services ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Parcel Pending developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Parcel Pending system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Parcel Pending API. # Vecos Source: https://docs.kodelabs.com/products/integrations/smart-lockers/vecos Connect Vecos to KODE OS for smart locker data > Connect Vecos to KODE OS for smart locker data integration ## Overview Use this integration to connect Vecos smart locker systems to KODE OS. You discover lockers and collect availability, access, and operational status over REST. | Property | Value | | - | - | | **System Type** | Smart Locker | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Vecos](https://kodelabs.com/integration/vecos/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Vecos and access to their API or developer portal * API key or token from the Vecos platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Vecos platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Vecos** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **User Key** | Yes | password | The user-specific key from the vendor platform | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Vecos system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Vecos, KODE OS maps them to the following device types and data points: ### smartLocker Canonical Type: `smartLocker` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `nrOfAllocations` | Number of locker allocations | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including nrOfAllocations, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor locker availability and assignment status across facilities * Track parcel delivery and pickup events for tenant services ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Vecos platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Vecos system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Vecos API. # Yale Accentra Source: https://docs.kodelabs.com/products/integrations/smart-lockers/yale Connect Yale Accentra to KODE OS for smart locker data > Connect Yale Accentra to KODE OS for smart locker data integration ## Overview Use this integration to connect Yale Accentra smart lockers to KODE OS. Scheduled polling collects lock events, battery health, and fault signals with historical retention for reliability tracking. | Property | Value | | - | - | | **System Type** | Smart Locker | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Yale Accentra](https://kodelabs.com/integration/yale/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Yale Accentra and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Yale Accentra developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Yale Accentra developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Yale Accentra** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **System ID** | Yes | password | The system identifier in the external platform | ## What Data You Get ### Audit Logs Access and security event records including badge swipes, door access events, person identification, timestamps, and access results KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique log entry identifier | | **Description** | Event description | | **Person Name** | Name of the person involved | | **Credential ID** | Badge or credential identifier used | | **Credential Type** | Type of credential (e.g., Card, PIN, Biometric) | | **Role** | Access role or clearance level | | **Type** | Event type (e.g., Entry, Exit, Denied) | | **Result** | Access result (Granted, Denied, Error) | | **Access Point** | Door or access point name | | **Location** | Physical location of the access point | | **Access Time** | Timestamp of the access event | | **Created At** | Timestamp when the log was recorded | ### Polling Schedule * **Audit Log** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor locker availability and assignment status across facilities * Track parcel delivery and pickup events for tenant services ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Yale Accentra developer portal. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Yale Accentra API. # Ryse Source: https://docs.kodelabs.com/products/integrations/smart-shades/ryse Connect Ryse to KODE OS for smart shades data > Connect Ryse to KODE OS for smart shades data integration ## Overview Use this integration to connect Ryse SmartShade devices to KODE OS. You discover shades and poll position, status, and control-related points over REST for scheduling and daylight management. | Property | Value | | - | - | | **System Type** | Smart Shades | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Ryse](https://kodelabs.com/integration/ryse/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Ryse and access to their API or developer portal * API key or token from the Ryse platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Ryse platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Ryse** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Region** | Yes | password | The cloud region where the vendor service is hosted | | **User Pool ID** | Yes | password | The AWS Cognito user pool ID for authentication | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Ryse system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Ryse, KODE OS maps them to the following device types and data points: ### blinds Canonical Type: `blinds` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 2 | `Position` | Current shade/blind position | -- | Yes | Polling | | 3 | `Normal` | **Normal** -- in resting position / **Moving Up** -- shade is raising / **Moving Down** -- shade is lowering / **Stopped Obstacle** -- movement halted due to obstruction | -- | No | Polling | | 4 | `Temperature` | Current temperature reading (°C) | °C | No | Polling | ## What Data You Get ### Point History Time-series readings including Online, Position, Normal, Temperature, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 30 seconds (min: 30 seconds, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Ryse data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Ryse platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Ryse system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Ryse API. # Eevion Hypercharge Source: https://docs.kodelabs.com/products/integrations/utility-power/hypercharge Connect Eevion Hypercharge to KODE OS for utility power status data > Connect Eevion Hypercharge to KODE OS for utility power status data integration ## Overview Use this integration to connect Hypercharge EV utility and charging data to KODE OS. REST discovery collects station status, sessions, and related operational records for utility power visibility. | Property | Value | | - | - | | **System Type** | Utility Power Status | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Eevion Hypercharge](https://kodelabs.com/integration/eevion/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Eevion Hypercharge and access to their API or developer portal * API key or token from the Eevion Hypercharge platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Eevion Hypercharge platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Eevion Hypercharge** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Eevion Hypercharge system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Eevion Hypercharge, KODE OS maps them to the following device types and data points: ### Power Monitor Canonical Type: `default` | # | Point | Description | Unit | Writable | Ontology Field | Collection | | - | - | - | - | - | - | - | | 1 | `Status` | Current operating status | -- | No | `connection_status` | Polling | | 2 | `kW` | Current power consumption (kW) | kW | No | `run_power_sensor` | Polling | | 3 | `amps` | Operating current reading (A) | A | No | `run_current_sensor` | Polling | | 4 | `volt` | Voltage reading (V) | V | No | `run_voltage_sensor` | Polling | ## What Data You Get ### Point History Time-series readings including Status, kW, amps, volt, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 5 hours) * **ChargePointSessions** -- Default polling: 1 hours (min: 1 hours, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Eevion Hypercharge data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Eevion Hypercharge platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Eevion Hypercharge system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Eevion Hypercharge API. # iSocket Source: https://docs.kodelabs.com/products/integrations/utility-power/iSocket Connect iSocket to KODE OS for utility power status data > Connect iSocket to KODE OS for utility power status data integration ## Overview Use this integration to connect iSocket smart outlets to KODE OS. REST and webhooks deliver outlet state, temperature, and leak-related telemetry with historical retention where configured. | Property | Value | | - | - | | **System Type** | Utility Power Status | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [iSocket](https://kodelabs.com/integration/isocket/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data * File Validation ## Prerequisites * An active account with iSocket and access to their API or developer portal * API key or token from the iSocket platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the iSocket platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the iSocket platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **iSocket** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | dropdown | The specific room this connector is associated with | | **API Key** | Yes | password | The API key for authenticating with the external system | | **File** | Yes | file | An upload file used during discovery (e.g., device whitelist spreadsheet) | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the iSocket system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from iSocket, KODE OS maps them to the following device types and data points: ### Power Monitor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Power Status` | **Normal** -- operating within expected parameters / **Alarm** -- abnormal condition detected | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including Power Status, collected at regular intervals from connected devices ### Alarms Alert and fault notifications including alarm name, priority, status, timestamps, device association, and acknowledgment state KODE OS maps iSocket data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `alarmId` | -- | | **name** | `"Power"` | -- | | **status** | `data.alert` | -- | | **createdAt** | mapped by connector | -- | | **deviceName** | `device.alias` | -- | | **deviceId** | `device.monitoringAlias` | -- | | **deviceName** | `device.alias` | conditional | | **deviceId** | `device.monitoringAlias` | conditional | ### Polling Schedule * **Point History** * **Alarm** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize iSocket data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the iSocket platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the iSocket platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the iSocket system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the iSocket system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the iSocket API. # Muse Source: https://docs.kodelabs.com/products/integrations/utility-power/muse Connect Muse to KODE OS for utility power status data > Connect Muse to KODE OS for utility power status data integration ## Overview Use this integration to bring Envizi (Muse) utility performance data into KODE OS. REST pulls monthly reports with performance measures, audit records, and cost data for utility and sustainability reporting. | Property | Value | | - | - | | **System Type** | Utility Power Status | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | ## Supported Capabilities * Collect Sensor Data * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data ## Prerequisites * An active account with Muse and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Muse** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Access Token** | Yes | password | The access token for API authentication | | **Location ID** | Yes | text | The location identifier in the external system | ## What Data You Get ### Cost Audits Cost audit records and financial tracking data ### Monthly Summaries Monthly aggregated data summaries for reporting ### Polling Schedule * **GsaMonthlyDataSummary** -- Default polling: 1 days (min: 1 days, max: 1 days) * **GsaRecordsAndCostAudits** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Muse data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Muse platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Muse API. # Carrot Source: https://docs.kodelabs.com/products/integrations/waste-metering/carrot Connect Carrot to KODE OS for waste metering data > Connect Carrot to KODE OS for waste metering data integration ## Overview Use this integration to connect Carrot waste tracking to KODE OS. You discover assets, collect sensor and operational waste data, and retain historical readings for sustainability reporting. | Property | Value | | - | - | | **System Type** | Waste Metering | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [Carrot](https://kodelabs.com/integration/carrot/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Carrot and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Carrot developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Carrot developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Carrot** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Client ID** | Yes | text | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Carrot system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `status` | status | | `access_point` | access point | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Event Logs System and security event records with timestamps, event types, and associated devices KODE OS maps Carrot data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `useEvent.id` | -- | | **name** | `type` | -- | | **status** | `useEvent.result.code` | -- | | **location** | `accessPoint` | transformed | | **deviceId** | `accessPoint.id` | -- | | **deviceName** | `accessPoint.name` | -- | | **createdAt** | `useEvent.createdAt` | transformed | | **updatedAt** | `useEvent.updatedAt` | transformed | | **customFields** | `(custom fields)` | -- | ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Carrot data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Carrot developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Carrot system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Carrot API. # Compology Source: https://docs.kodelabs.com/products/integrations/waste-metering/compology Connect Compology to KODE OS for waste metering data > Connect Compology to KODE OS for waste metering data integration ## Overview Use this integration to connect Compology dumpster monitoring to KODE OS. REST polling surfaces fill levels, camera-derived metrics, and operational waste data for collection planning. | Property | Value | | - | - | | **System Type** | Waste Metering | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Compology](https://kodelabs.com/integration/compology/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Collect Non-Sensor Data ## Prerequisites * An active account with Compology and access to their API or developer portal * Username and password credentials for the Compology system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Compology** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Compology system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Compology, KODE OS maps them to the following device types and data points: ### wasteCollector Canonical Type: `wasteCollector` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Camera Blocked` | **True** -- access point is locked / **False** -- access point is unlocked | -- | No | Polling | | 2 | `ongoing_object_counter` | Running count of detected waste disposal events | count | No | Polling | | 3 | `Level` | Current level value | % | No | Polling | | 4 | `Last Emptied At` | Timestamp of the last emptying/collection event | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Camera Blocked, ongoing\_object\_counter, Level, Last Emptied At, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **CompologyPickupSchedule** -- Default polling: 1 days (min: 1 days, max: 1 days) * **CompologyFullnessAtPickupStats** -- Default polling: 1 days (min: 1 days, max: 1 days) * **CompologyDumpsterFullnessIncreaseStats** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize Compology data in your building operations dashboard * Correlate data from this system with other building systems for comprehensive analytics ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Compology system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Compology system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Compology API. # Tempest Source: https://docs.kodelabs.com/products/integrations/weather/tempest Connect Tempest to KODE OS for weather data > Connect Tempest to KODE OS for weather data integration ## Overview Use this integration to connect Tempest weather stations to KODE OS. You discover devices and collect live meteorological readings over REST for on-site weather context. | Property | Value | | - | - | | **System Type** | Weather Data | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [Tempest](https://kodelabs.com/integration/tempest/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data ## Prerequisites * An active account with Tempest and access to their API or developer portal * API key or token from the Tempest platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Tempest platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Tempest** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Token** | Yes | password | The API token for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Tempest system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Tempest, KODE OS maps them to the following device types: * **Weather Station** (`externalWeather`) | Point | Display Name | | - | - | | `relativeHumidity` | relativeHumidity | | `pressure` | pressure | | `airTemperature` | airTemperature | | `battery` | battery | | `lightningStrikeCount` | lightningStrikeCount | | `lightningAverageDistance` | lightningAverageDistance | | `Relative Humidity` | Relative Humidity | | `Pressure` | Pressure | | `Air Temperature` | Air Temperature | | `Lightning Strike Count` | Lightning Strike Count | | `Lightning Average Distance` | Lightning Average Distance | | `Battery` | Battery | | `Illuminance` | Illuminance | | `Uv` | Uv | | `Wind Average` | Wind Average | | `Wind Direction` | Wind Direction | | `Rain Accumulation` | Rain Accumulation | | `Solar Radiation` | Solar Radiation | | `Precipitation Type` | Precipitation Type | ## What Data You Get ### Point History Time-series sensor readings such as temperature, humidity, CO2, occupancy counts, energy consumption, light levels, and other measurable values from physical sensors ### Polling Schedule * **Point History** -- Default polling: 1 minutes (min: 1 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Incorporate external weather conditions into building optimization models * Correlate energy consumption with outdoor temperature and humidity trends ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Tempest platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Tempest system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Tempest API. # iCare Source: https://docs.kodelabs.com/products/integrations/wireless-sensors/iCare Connect iCare to KODE OS for wireless sensors data > Connect iCare to KODE OS for wireless sensors data integration ## Overview Use this integration to connect iCare wireless industrial sensors to KODE OS. REST and webhooks deliver predictive maintenance readings and device events for monitored equipment. | Property | Value | | - | - | | **System Type** | Wireless Sensors | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [iCare](https://kodelabs.com/integration/icare/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites To integrate with the iCare API, ensure you have the following details: * An active account in [https://login.icaremillc.com](https://login.icaremillc.com) with the appropriate access permissions. * Valid username and password credentials for the iCare platform. ## Generate API Credentials * Log in to the [https://login.icaremillc.com](https://login.icaremillc.com) using your username and password * In the left sidebar, click on API. * Select API Keys. * Click the + Generate Key button. * Copy both the API Key ID and the API Secret Key. * ⚠️ This is a one-time view — the API Secret Key will not be visible again. If it's lost, you’ll need to delete the key and generate a new one. ## Configure Webhook * Send Gateway Message: Select Only with sensor messages * Authentication: Set to None * Click Save to complete the setup. ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **iCare** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | text | The API key for authenticating with the external system | | **API Secret Key** | Yes | password | The secret key for API authentication | | **Network ID** | Yes | password | Configuration field for Network ID | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the iCare system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from iCare, KODE OS maps them to the following device types and data points: ### Wireless Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `signalStrength` | Wireless signal strength | -- | No | Webhook | | 2 | `batteryLevel` | Device battery level (%) | % | No | Webhook | | 3 | `currentReading` | Current meter reading | -- | No | Webhook | | 4 | `voltage` | Voltage reading (V) | V | No | Webhook | ## What Data You Get ### Point History Time-series readings including signalStrength, batteryLevel, currentReading, voltage, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor distributed sensor networks for temperature, humidity, motion, and environmental data * Receive real-time alerts from battery-powered sensors across the facility ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the iCare platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the iCare platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the iCare system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the iCare system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the iCare API. # iMonnit API Source: https://docs.kodelabs.com/products/integrations/wireless-sensors/imonnit Connect iMonnit API to KODE OS for wireless sensors data > Connect iMonnit API to KODE OS for wireless sensors data integration ## Overview Use this integration to connect iMonnit wireless sensors to KODE OS. Webhook push and discovery keep temperature, humidity, and related IoT readings synchronized in the platform. | Property | Value | | - | - | | **System Type** | Wireless Sensors | | **Communication** | REST + Webhook | | **Collection** | Push | | **Collection Mode** | SNAPSHOT | See [iMonnit API](https://kodelabs.com/integration/monnit/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Sensor Data * Receive Webhook Data ## Prerequisites * An active account with iMonnit API and access to their API or developer portal * API key or token from the iMonnit API platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the iMonnit API platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the iMonnit API platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **iMonnit API** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Secret Key** | Yes | password | The secret key for API authentication | | **API Building ID** | Yes | password | The building or source identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the iMonnit API system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from iMonnit API, KODE OS maps them to the following device types and data points: ### Wireless Sensor Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `SignalStrength` | Wireless signal strength (%) | % | No | Webhook | | 2 | `BatteryLevel` | Device battery level (%) | % | No | Webhook | | 3 | `Voltage` | Voltage reading (V) | V | No | Webhook | | 4 | `MessageCount` | Cumulative count of messages sent | -- | No | Webhook | | 5 | `Power` | Current power reading | -- | No | Webhook | ## What Data You Get ### Point History Time-series readings including SignalStrength, BatteryLevel, Voltage, MessageCount, Power, collected at regular intervals from connected devices ### Polling Schedule * **Point History** -- Default polling: 2 hours (min: 2 hours, max: 2 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Monitor distributed sensor networks for temperature, humidity, motion, and environmental data * Receive real-time alerts from battery-powered sensors across the facility ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the iMonnit platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the iMonnit platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the iMonnit system can reach the KODE OS webhook endpoint over the network. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the iMonnit system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the iMonnit API. # Angus Source: https://docs.kodelabs.com/products/integrations/work-orders/angus Connect Angus to KODE OS for work orders data > Connect Angus to KODE OS for work orders data integration ## Overview Use this integration to connect Angus to KODE OS. You can discover devices and points, collect sensor and non-sensor data with hybrid snapshot collection, and use supported actions for work order workflows. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Angus](https://kodelabs.com/integration/angus/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data ## Prerequisites * An active account with Angus and access to their API or developer portal * Username and password credentials for the Angus system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Angus** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **File Name** | Yes | text | The name of the file to upload or reference | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Angus system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Angus, KODE OS maps them to the following device types and data points: ### IO Reader / Controller Canonical Type: `IOREADER` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `INACTIVE` | **True** -- INACTIVE is active / **False** -- INACTIVE is not active | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including INACTIVE, collected at regular intervals from connected devices ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Angus data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `displayId` | -- | | **title** | `trade` | -- | | **description** | mapped by connector | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **floor** | `floor` | -- | | **location** | `suite` | -- | | **assignedTo** | `assignedTo` | -- | | **createdAt** | mapped by connector | transformed | | **updatedAt** | `statusDate` | -- | | **dueDate** | mapped by connector | transformed | | **completedAt** | mapped by connector | transformed | | **duration** | `actTime` | -- | | **resolutionDetails** | `closureNotes` | -- | | **assetId** | `equipmentId` | -- | | **assetType** | `system` | -- | | **customFields** | `(custom fields)` | custom fields object | | **id** | `displayID` | -- | | **title** | `trade` | -- | | **description** | `woDetail` | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **category** | `requestType` | -- | | **subCategory** | `bulletinType` | -- | | **floor** | `floor` | -- | | **location** | `suite` | -- | | **problemCause** | `delayComment` | -- | | **createdBy** | mapped by connector | -- | | **assignedTo** | `assignedTo` | -- | | **createdAt** | mapped by connector | transformed | | **updatedAt** | `statusDate` | -- | | **dueDate** | mapped by connector | transformed | | **startedAt** | mapped by connector | transformed | | **completedAt** | mapped by connector | transformed | | **duration** | `timeCompletion` | -- | | **resolutionDetails** | `closureNotes` | -- | | **estimatedCost** | `totalAmountEstimated` | -- | | **lastComment** | `qrsComment` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Equipment Equipment inventory and metadata records including equipment type, model, location, and maintenance status ### Polling Schedule * **WorkOrder** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) * **Equipment** -- Default polling: 1 hours (min: 1 hours, max: 1 days) * **Point History** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in the Angus AnyWhere system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Priority** | STRING | Yes | Drop Down | Static priority list | | **WO Title** | STRING | Yes | Text Box | -- | | **Instructions** | STRING | No | Text Area | -- | | **Estimated Time** | INTEGER | Yes | Number | -- | | **Trade** | STRING | Yes | Drop Down | Static trades list | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "Priority": "High", "WOTitle": "example-value", "EstTime": "2026-03-29T10:00:00Z", "Trade": "example-value", "Instructions": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Angus system. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Angus system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Angus API. # AssetOps Source: https://docs.kodelabs.com/products/integrations/work-orders/assetOps Connect AssetOps to KODE OS for work orders data > Connect AssetOps to KODE OS for work orders data integration ## Overview Use this integration to connect AssetOps to KODE OS. You can collect work order and related operational data over REST with hybrid historical collection, sync sensor and non-sensor readings, and use supported connector actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with AssetOps and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in KODE OS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **AssetOps** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Devices and Points | Point | Display Name | | - | - | | `dueDate` | dueDate | | `title` | title | | `description` | description | | `assignees` | assignees | | `category` | category | | `issueType` | issueType | | `team` | team | | `vendor` | vendor | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps AssetOps data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **woNumber** | `number` | -- | | **title** | `title` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **startedAt** | derived value | transformed | | **dueDate** | derived value | transformed | | **createdAt** | derived value | transformed | | **updatedAt** | derived value | transformed | | **completedAt** | derived value | transformed | | **assignedTo** | derived value | transformed | | **createdBy** | `createdBy.firstName` | transformed | | **location** | `area.name` | transformed | | **serviceProvider** | `vendor.name` | transformed | | **priority** | `priority.name` | -- | | **category** | `category.name` | -- | | **subCategory** | `issueType.name` | Also stored in custom fields as `sub_category` | | **customFields** | `(custom fields)` | custom fields object | | **assetId** | `asset.id` | -- | | **assetName** | `asset.name` | -- | | **assetId** | `asset.id` | conditional | ### Polling Schedule * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in AssetOps | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | Yes | Text Box | -- | | **Description** | STRING | No | Text Area | -- | | **Assignees** | STRING | No | Drop Down | Dynamic: fetched from AssetOps API | | **Category** | STRING | Yes | Drop Down | Dynamic: fetched from AssetOps API | | **Issue Type** | STRING | Yes | Drop Down | Dynamic: filtered by selected category | | **Team** | STRING | No | Drop Down | Dynamic: fetched from AssetOps API | | **Vendor** | STRING | No | Drop Down | Dynamic: fetched from AssetOps API | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "category": "example-value", "issueType": "example-value", "description": "example-value", "assignees": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the AssetOps platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the AssetOps API. # BuiltSpace Source: https://docs.kodelabs.com/products/integrations/work-orders/builtspace Connect BuiltSpace to KODE OS for work orders data > Connect BuiltSpace to KODE OS for work orders data integration ## Overview Use this integration to connect BuiltSpace to KODE OS. You can pull historical sensor and non-sensor data over REST so work orders and building context stay aligned across your portfolio. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | HISTORICAL | See [BuiltSpace](https://kodelabs.com/integration/built-space/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with BuiltSpace and access to their API or developer portal * API key or token from the BuiltSpace platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the BuiltSpace platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **BuiltSpace** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## What Data You Get ### Inspections Facility inspection records including checklist results, findings, and compliance status ### Tasks Facility task records including assignment, status, priority, and completion details ### Polling Schedule * **BuiltSpaceInspections** -- Default polling: 1 days (min: 1 days, max: 1 days) * **BuiltSpaceTasks** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the BuiltSpace platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the BuiltSpace API. # CF Connect Source: https://docs.kodelabs.com/products/integrations/work-orders/cfConnect Connect CF Connect to KODE OS for work orders data > Connect CF Connect to KODE OS for work orders data integration ## Overview Use this integration to connect CF Connect to KODE OS for work orders tied to your Salesforce-connected environment. You can collect sensor and non-sensor data with hybrid historical collection and use supported actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites To integrate with the CF Connect API, ensure you have the following details: * An active account in [https://cf--uat.sandbox.my.salesforce.com](https://cf--uat.sandbox.my.salesforce.com) with the appropriate access permissions. * You will need to obtain a prod link here ⬆️ * Valid username and password credentials for CF Salesforce platform. ## Generate API Credentials Obtain Credentials 4 * Go to the CF Salesforce App * Sign in using your username and password. * Click the settings button (⚙️) in the top navigation bar (upper right corner) and select Setup. * Navigate to the Apps > External Client Apps > External Client App Manager tab. * Click the New External Client App button on the right upper side. * Enter the basic information: * External Client App Name * Contact Email * API Name * Select the Distribution State * Under API (Enable OAuth Settings) check option Enable OAuth ✔️ * Under App Settings provide the Callback URL [https://www.test.salesforce.com/oauth2/callback](https://www.test.salesforce.com/oauth2/callback) * Under OAuth Scopes select your options, i.e * Manage user data via APIs (api) * Manage user data via Web browsers (web) * Full access (full) * Under Flow Enablement check options * Enable Client Credentials Flow ✔️ * Enable Authorization Code and Credentials Flow ✔️ * Under Security check options * Require secret for Web Server Flow ✔️ * Require secret for Refresh Token Flow ✔️ * Finally, click on Create ✔️ Steps to Obtain Credentials * Click on the external app created in the previous step * Select the Settings tab * Under OAuth Settings > App Settings click on button Consumer Key and Secret After completing the steps above, your Consumer Key and Consumer Secret will be used in the next step. ⬇️ ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **CF Connect** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps CF Connect data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **title** | `title` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **category** | `category` | -- | | **subCategory** | `subCategory` | -- | | **location** | `location` | -- | | **createdBy** | `createdBy.name` | transformed | | **assignedTo** | `assignedTo` | -- | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `updatedAt` | transformed | | **startedAt** | `startedAt` | transformed | | **completedAt** | `completedAt` | transformed | | **duration** | `completionTime` | -- | | **serviceProvider** | `serviceProvider` | -- | | **lastComment** | `lastComment` | -- | | **externalUrl** | `attributes` | transformed | | **problemCause** | `problemCause` | -- | | **customFields** | `(custom fields)` | custom fields object | | **id** | `id` | -- | | **title** | `title` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **category** | `category` | -- | | **subCategory** | `subCategory` | -- | | **location** | `location` | -- | | **createdBy** | `createdBy.name` | transformed | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `updatedAt` | transformed | | **dueDate** | `dueDate` | transformed | | **startedAt** | `startedAt` | transformed | | **completedAt** | `completedAt` | transformed | | **duration** | `completionTime` | -- | | **lastComment** | `lastComment` | -- | | **externalUrl** | `attributes` | transformed | | **problemCause** | `problemCause` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Case **Type:** Write Creates a new support case in CF Connect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | Yes | Text Area | -- | | **Description** | STRING | Yes | Text Area | -- | | **Ticket Type** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Priority** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Category** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Sub Category** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Location** | STRING | Yes | Drop Down | Dynamic: fetched from CF Connect locations | | **Service Provider** | STRING | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "description": "example-value", "location": "example-value", "ticketType": "example-value", "priority": "High" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Create Work Order **Type:** Write Creates a new work order linked to a case in CF Connect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | Yes | Text Area | -- | | **Description** | STRING | Yes | Text Area | -- | | **Priority** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Service Provider** | STRING | No | Text Box | -- | | **Case** | STRING | Yes | Drop Down | Dynamic: fetched from CF Connect cases | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "description": "example-value", "caseId": "12345", "priority": "High", "serviceProvider": "12345" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Case **Type:** Write Updates an existing case in CF Connect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | No | Text Area | -- | | **Description** | STRING | No | Text Area | -- | | **Priority** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Category** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Sub Category** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Status** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Location** | STRING | No | Drop Down | Dynamic: fetched from CF Connect locations | | **Start Date** | DATE\_TIME | No | Text Box | -- | | **Service Provider** | STRING | No | Text Box | -- | | **Comment** | STRING | No | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "description": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Work Order **Type:** Write Updates an existing work order in CF Connect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | No | Text Area | -- | | **Description** | STRING | No | Text Area | -- | | **Priority** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Status** | STRING | No | Drop Down | Dynamic: fetched from CF Connect picklists | | **Start Date** | DATE\_TIME | No | Text Box | -- | | **Due Date** | DATE\_TIME | No | Text Box | -- | | **Service Provider** | STRING | No | Text Box | -- | | **Comment** | STRING | No | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "description": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the CF Connect platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the CF Connect API. # Cfs GS Source: https://docs.kodelabs.com/products/integrations/work-orders/cfsGS Connect Cfs GS to KODE OS for work orders, asset, reservations, other data > Connect Cfs GS to KODE OS for work orders, asset, reservations, other data integration ## Overview Use this integration to connect CFS GS to KODE OS for work orders, assets, reservations, and related data. You can discover devices and points, collect operational data with hybrid snapshot collection, and run supported connector actions where the API allows. | Property | Value | | - | - | | **System Type** | Work Orders, Asset, Reservations, Other | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data * Discover Assets ## Prerequisites * An active account with Cfs GS and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Cfs GS developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Cfs GS developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Cfs GS** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Tenant ID** | Yes | password | The tenant identifier in the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **Environment** | Yes | dropdown | The deployment environment to connect to | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Cfs GS system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points | Point | Display Name | | - | - | | `msdyn_name` | msdyn name | | `gs_criticality` | gs criticality | | `gs_type` | gs type | | `gs_locationarea` | gs locationarea | | `gs_macaddress` | gs macaddress | | `gs_model` | gs model | | `gs_installeddate` | gs installeddate | | `statuscode` | statuscode | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Cfs GS data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `workOrder.msdynWorkOrderId` | -- | | **title** | `workOrder.msdynName` | -- | | **description** | `workOrder.gsWorkOrderDetails` | -- | | **status** | `workOrder.gsWoStatusFormatted` | -- | | **priority** | `workOrder.msdynPriorityValueFormatted` | -- | | **category** | `workOrder.msdynWorkOrderTypeValueFormattedValue` | -- | | **subCategory** | `workOrder.gsWoClassValueFormatted` | -- | | **location** | `workOrder.gsDeskLocation` | -- | | **floor** | `workOrder.gsFloorFormula` | -- | | **createdBy** | `workOrder.createdByValueFormatted` | -- | | **assignedTo** | `workOrder.gsAssignedToValueFormatted` | -- | | **assignmentGroup** | `workOrder.gsAssignedToPoolValueFormatted` | -- | | **createdAt** | `workOrder.createdOn` | transformed | | **updatedAt** | `workOrder.modifiedOn` | transformed | | **dueDate** | `workOrder.msdynDateWindowEnd` | transformed | | **startedAt** | `workOrder.gsWorkStartDateOnWo` | transformed | | **completedAt** | `workOrder.gsDateCompleted` | transformed | | **duration** | `workOrder.gsHoursWorkedOnWorkOrder` | -- | | **serviceProvider** | `workOrder.gsServiceProviderIdValue` | -- | | **problemCause** | `workOrder.gsProblemCodeOnWoValue` | -- | | **resolutionDetails** | `workOrder.msdynWorkOrderResolutionKpiIdValue` | -- | | **lastComment** | `workOrder.gsComments` | -- | | **assetName** | `workOrder.msdynCustomerAsset` | -- | | **externalUrl** | `workOrder.gsRecordUrl` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Assets Asset inventory records including asset type, location, condition, and associated metadata ### Polling Schedule * **WorkOrder** -- Default polling: 5 minutes (min: 5 minutes, max: 60 minutes) * **Asset** -- Default polling: 15 minutes (min: 5 minutes, max: 60 minutes) * **GsPmSchedule** -- Default polling: 1 hours (min: 1 hours, max: 6 hours) * **GsBookLabor** -- Default polling: 7 days (min: 7 days, max: 7 days) * **GsBooking** * **GsBookingDate** * **GsServiceRequest** * **GsSurvey** * **GsServiceProvider** * **GsBuilding** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in the CFS GS (Dynamics 365 Field Service) system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Project ID** | STRING | Yes | Text Area | KODE Alarm | | **Description** | STRING | Yes | Text Area | -- | | **Priority** | STRING | Yes | Text Area | Life-Safety → High, Critical → High, Warning → Medium, Alert → Low, Info → Low | | **Work Order Type** | STRING | Yes | Drop Down | Dynamic: fetched from CFS work order types API | | **CFS Asset** | STRING | Yes | Drop Down | Dynamic: fetched from CFS customer assets API | | **Incident Type** | STRING | Yes | Drop Down | Dynamic: fetched from CFS incident types API (auto-filled for alarm-type WOs) | | **Safety Related** | STRING | Yes | Drop Down | Static: NO, YES | | **Assignee** | STRING | Yes | Drop Down | Dynamic: fetched from CFS bookable resources API | | **Comment** | STRING | Yes | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "gsProjectidJmac": "12345", "gs_workorderdetails": "example-value", "msdyn_priority": "High", "msdyn_workordertype": "example-value", "msdyn_customerasset": "example-value", "msdyn_primaryincidenttype": "12345", "gs_safetyrelated": "NO", "gs_AssignedTo": "example-value", "gs_comments": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Create Asset **Type:** Write Creates a new asset record in the CFS GS system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Name** | STRING | Yes | Text Box | -- | | **Criticality** | STRING | Yes | Drop Down | -- | | **Type** | STRING | No | Drop Down | -- | | **Location** | STRING | No | Text Box | -- | | **MAC Address** | STRING | No | Text Box | -- | | **Model** | STRING | No | Text Box | -- | | **Serial Number** | STRING | No | Text Box | -- | | **Installation Date** | DATE | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "msdyn_name": "example-value", "gs_criticality": "example-value", "gs_type": "example-value", "gs_locationArea": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Update Asset **Type:** Write Updates an existing asset record in the CFS GS system | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Name** | STRING | Yes | Text Box | -- | | **Criticality** | STRING | Yes | Drop Down | -- | | **Type** | STRING | No | Drop Down | -- | | **Location** | STRING | No | Text Box | -- | | **MAC Address** | STRING | No | Text Box | -- | | **Model** | STRING | No | Text Box | -- | | **Serial Number** | STRING | No | Text Box | -- | | **Installation Date** | DATE | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "msdyn_name": "example-value", "gs_criticality": "example-value", "gs_type": "example-value", "gs_locationArea": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost * Centralize space and resource booking data across platforms ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Cfs GS developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Cfs GS system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Cfs GS API. # Corrigo Source: https://docs.kodelabs.com/products/integrations/work-orders/corrigo Connect Corrigo to KODE OS for work orders data > Connect Corrigo to KODE OS for work orders data integration ## Overview Use this integration to connect Corrigo to KODE OS. You can discover devices and points, collect work order and facilities data over REST with hybrid snapshot collection, and use supported actions for maintenance workflows across your portfolio. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Corrigo](https://kodelabs.com/integration/corrigo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data ## Prerequisites * An active account with Corrigo and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Corrigo developer portal * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [Corrigo developer hub](https://developer.corrigo.com/) * [Corrigo entities and operations](https://developer.corrigo.com/reference/entities) ## Generate API Credentials 1. Log in to the Corrigo developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Corrigo** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Client Name** | Yes | text | The client application name registered with the vendor | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Corrigo system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Corrigo, KODE OS maps them to the following device types and data points: ### IO Reader / Controller Canonical Type: `IOREADER` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `is_online` | **True** -- device is connected and reporting / **False** -- device is not responding | -- | No | Polling | | 2 | `is_locked` | **True** -- access point is locked / **False** -- access point is unlocked | -- | No | Polling | | 3 | `is_restricted` | **True** -- access is restricted / **False** -- access is not restricted | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including is\_online, is\_locked, is\_restricted, collected at regular intervals from connected devices ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Corrigo data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **assignedTo** | `additionalInfo.employeeDisplay` | -- | | **lastComment** | `additionalInfo.lastActionComment` | -- | | **priority** | `additionalInfo.priorityDisplay` | -- | | **id** | `number` | -- | | **description** | `taskRefinement` | -- | | **status** | `statusId` | -- | | **category** | `typeCategory` | -- | | **location** | `shortLocation` | -- | | **createdAt** | `createdDateUtc` | transformed | | **updatedAt** | `lastActionDateUtc` | transformed | | **dueDate** | `dueDateUtc` | transformed | | **duration** | `duration` | -- | | **estimatedCost** | `vendorNte.value + vendorNte.currencyTypeId` | -- | | **assetId** | `mainAsset.stringValue` | transformed | ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) * **WorkOrder** -- Default polling: 5 minutes (min: 5 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Corrigo Work Order **Type:** Write Creates a new work order in Corrigo Enterprise. Requires only a comment; work order context (building, device, priority) is auto-populated from the KODE OS alarm or device. | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Comment** | STRING | Yes | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "comment": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Corrigo developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Corrigo system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Corrigo API. # Cove Source: https://docs.kodelabs.com/products/integrations/work-orders/cove Connect Cove to KODE OS for work orders data > Connect Cove to KODE OS for work orders data integration ## Overview Use this integration to connect Cove to KODE OS for work order lifecycle data. You can collect sensor and non-sensor data with hybrid historical collection, keep work orders synchronized through the connector, and use supported actions from KODE OS. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with Cove and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Cove** 3. Click **+ Add Datasource** 4. Complete the three-page setup flow using the credential prerequisites for this integration > [!NOTE] > > Connector field metadata is not exposed in code for this integration. Configure the connector using your standard credentials and endpoint details shown in the prerequisites and vendor onboarding references. ## Devices and Points | Point | Display Name | | - | - | | `description` | description | | `dueDate` | dueDate | | `floorId` | floorId | | `suiteId` | suiteId | | `ticketType` | ticketType | | `categoryId` | categoryId | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Cove data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **title** | `workOrderCategory.title` | transformed | | **description** | `description` | -- | | **status** | `status` | -- | | **category** | `ticketType` | -- | | **floor** | `floor.name` | transformed | | **createdBy** | `createdBy.email` | transformed | | **assignedTo** | `assignee.id` | transformed | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `updatedAt` | transformed | | **dueDate** | `requiredDueAt` | transformed | | **completedAt** | `completedAt` | transformed | | **duration** | `hoursLogged` | -- | | **estimatedCost** | `totalCharge` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in Cove | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Description** | STRING | Yes | Text Area | -- | | **Due Date** | DATE\_TIME | No | Text Box | -- | | **Category** | STRING | Yes | Drop Down | Dynamic: fetched from Cove categories API | | **Floor** | STRING | Yes | Drop Down | Dynamic: fetched from Cove floors API | | **Suite** | STRING | Yes | Drop Down | Dynamic: fetched from Cove suites API (filtered by floor) | | **Ticket Type** | STRING | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "description": "example-value", "categoryId": "12345", "floorId": "12345", "suiteId": "12345", "dueDate": "2026-03-29T10:00:00Z", "ticketType": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Cove platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Cove API. # Gridium Source: https://docs.kodelabs.com/products/integrations/work-orders/gridium Connect Gridium to KODE OS for work orders data > Connect Gridium to KODE OS for work orders data integration ## Overview Use this integration to connect Gridium to KODE OS. You can ingest work order and building operations data over REST and webhooks with snapshot collection so occupant, vendor, and staff activity stays visible in your portfolio. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST + Webhook | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported Capabilities * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Gridium and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Gridium platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Gridium** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **External URL** | No | text | An additional external URL for the integration | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Gridium data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `request.id` | -- | | **woNumber** | `request.workOrder` | -- | | **title** | `request.title` | -- | | **description** | `request.description` | -- | | **status** | `request.status` | -- | | **priority** | `request.priority` | -- | | **category** | mapped by connector | -- | | **location** | mapped by connector | -- | | **createdBy** | mapped by connector | -- | | **assignedTo** | mapped by connector | -- | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **dueDate** | mapped by connector | -- | | **lastComment** | mapped by connector | -- | | **lastCommentBy** | mapped by connector | -- | | **externalUrl** | `externalUrl` | -- | ### Polling Schedule * **WorkOrder** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Gridium platform. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Gridium platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Gridium system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Gridium API. # Impak Source: https://docs.kodelabs.com/products/integrations/work-orders/impak Connect Impak to KODE OS for work orders data > Connect Impak to KODE OS for work orders data integration ## Overview Use this integration to connect Impak to KODE OS. You can collect sensor and non-sensor work order data over REST with hybrid snapshot collection and use supported connector actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Impak](https://kodelabs.com/integration/impak/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with Impak and access to their API or developer portal * API key or token from the Impak platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Impak platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Impak** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## Devices and Points | Point | Display Name | | - | - | | `getSensorList` | getSensorList | | `getWorkOrderSensor` | getWorkOrderSensor | | `createWorkOrderSensor` | createWorkOrderSensor | | `APM` | APM | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Impak data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `workOrderId` | -- | | **description** | `request` | -- | | **status** | `wOStatus` | -- | | **priority** | `priority` | -- | | **category** | `jobType` | -- | | **location** | `serviceLocation` | -- | | **createdBy** | `requestor` | -- | | **assignmentGroup** | `technicians` | -- | | **createdAt** | mapped by connector | -- | | **dueDate** | mapped by connector | -- | | **startedAt** | mapped by connector | -- | | **completedAt** | mapped by connector | -- | | **estimatedCost** | `billable` | -- | | **serviceProvider** | `contractor` | -- | | **resolutionDetails** | `technicianNotes` | -- | | **assetId** | `equipmentId` | -- | | **assetName** | `equipment` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 30 minutes (min: 30 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in Impak | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Sensor Identifier** | STRING | Yes | Text Box | -- | | **Work Order Detail** | STRING | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "sensorIdentifier": "12345", "workOrderDetail": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Impak platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Impak API. # MaintainX Source: https://docs.kodelabs.com/products/integrations/work-orders/maintainX Connect MaintainX to KODE OS for assets, current meter readings, and work orders > Connect MaintainX to KODE OS for asset, meter, and work order data ## Overview Use this integration to collect MaintainX assets, current meter readings, and work orders. KODE OS represents assets as devices, asset meters as points, and maintenance records as work orders. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | ## Supported capabilities * Discover devices and points * Collect current meter readings * Collect work orders ## Prerequisites * A MaintainX account with access to API keys * A MaintainX API key * Access to the required organization and location * KODE OS access to `Data Sources` ## Generate an API key 1. Open [MaintainX API Keys](https://app.getmaintainx.com/settings/integrations/apiKeys). 2. Generate an API key for the integration. 3. Copy the key and store it securely. ## Configure the connector in KODE OS 1. Open `Data Sources` for your building. 2. Select `API Catalog`, then search for `MaintainX API`. 3. Select `+ Add Datasource`. 4. Complete the connector fields. | Field | Required | Type | Description | | - | - | - | - | | **Name** | Yes | text | Name that identifies this connection in KODE OS | | **Area** | No | dropdown | Area associated with the connection | | **URL** | Yes | text | MaintainX API base URL, such as `https://api.getmaintainx.com` | | **API Key** | Yes | password | Static Bearer token generated in MaintainX | | **Organization ID** | Yes | dropdown | MaintainX organization to collect | | **Location ID** | Yes | dropdown | Location within the selected organization | | **Notes** | No | text | Additional connection details | Multi-organization tokens require an organization header. KODE OS uses the organization selected on the connector. ## Discover devices and points After you save the connector, select `Discover`. Review the returned assets and meter points, then save the records you want in KODE OS. MaintainX meters without an associated asset are not available for discovery. One asset can contain multiple meter points. For more details, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and points Each MaintainX asset becomes a KODE OS device. The connector creates one point for each associated meter. | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | | `lastReading.value` | Most recent numeric meter reading | Unit configured on the MaintainX meter | No | Polling | The MaintainX REST API provides the current reading only. It does not provide meter-reading history. ## What data you get ### Assets Asset records include the name, location, manufacturer, model, status, external ID, parent, and description. ### Work orders | KODE field | MaintainX field | | - | - | | **id** | `id` | | **woNumber** | `sequentialId` | | **title** | `title` | | **description** | `description` | | **status** | `status` | | **priority** | `priority` | | **category** | `type` | | **asset** | `asset.id` and `asset.name` | | **location** | `locationId` | | **assignedTo** | `assignees.id` | | **dueDate** | `dueDate` | | **startedAt** | `startDate` | | **completedAt** | `completedAt` | | **createdAt** | `createdAt` | | **updatedAt** | `updatedAt` | Supported statuses include `OPEN`, `IN_PROGRESS`, `ON_HOLD`, `DONE`, `CANCELED`, and `SKIPPED`. Supported priorities include `NONE`, `LOW`, `MEDIUM`, and `HIGH`. ### Polling schedule * **Current meter readings** — Approximately every 10 minutes KODE OS stores a new meter value only when the reading date changes. ## Use cases Once connected, you can: * Monitor MaintainX asset status and current meter values * Review work orders across locations * Analyze maintenance status, priority, assignees, and due dates in KODE OS ## Troubleshooting > [accordion] Authentication or connection error > > Verify the API key is active. For a multi-organization token, confirm the connector uses the correct organization. > [accordion] A meter is missing from discovery > > Confirm the meter is associated with a MaintainX asset. Meters without an asset cannot become points on a KODE OS device. > [accordion] Meter history is unavailable > > MaintainX exposes only `lastReading` through this REST integration. KODE OS begins building history from the current values collected after connection. # Manager Plus Source: https://docs.kodelabs.com/products/integrations/work-orders/managerPlus Connect Manager Plus to KODE OS for work orders data > Connect Manager Plus to KODE OS for work orders data integration ## Overview Use this integration to connect Manager Plus to KODE OS. You can discover devices and points, sync inspections, work orders, and inventory-related data over REST with hybrid snapshot collection, and use supported actions where the API allows. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data ## Prerequisites * An active account with Manager Plus and access to their API or developer portal * API key or token from the Manager Plus platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Manager Plus platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Manager Plus** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Manager Plus system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Manager Plus, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `Status` | Current operating status | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including Status, collected at regular intervals from connected devices ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps the collected data to these standard fields: | KODE Field | Description | | - | - | | **ID** | Unique work order identifier from the external system | | **WO Number** | Display work order number | | **Title** | Work order title or subject line | | **Description** | Detailed work order description and scope of work | | **Status** | Current work order status (e.g., Open, In Progress, Completed, Cancelled) | | **Priority** | Work order priority level (e.g., High, Medium, Low) | | **Type** | Work order type classification | | **Category** | Work order category (e.g., Corrective, Preventive, Inspection) | | **Sub-Category** | Work order sub-category for finer classification | | **Location** | Physical location where the work is performed | | **Floor** | Floor identifier within the building | | **Problem Cause** | Root cause or problem code associated with the work order | | **Created By** | Person or system that created the work order | | **Assigned To** | Individual assigned to perform the work | | **Assignment Group** | Team or group responsible for the work order | | **Created At** | Timestamp when the work order was created | | **Updated At** | Timestamp of the last modification | | **Due Date** | Target completion date for the work order | | **Started At** | Timestamp when work began | | **Completed At** | Timestamp when work was completed | | **Duration (min)** | Total time spent on the work order in minutes | | **Service Provider** | External vendor or contractor performing the work | | **Resolution** | Description of how the issue was resolved | | **Estimated Cost** | Estimated cost of the work order | | **Last Comment** | Most recent comment or note on the work order | | **Asset** | Name of the asset or equipment this work order is for | | **External URL** | Link to the work order in the external system | ### Polling Schedule * **Point History** -- Default polling: 1 hours (min: 1 hours, max: 1 hours) * **WorkOrder** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in ManagerPlus | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Purpose** | STRING | Yes | Text Box | -- | | **Priority** | INTEGER | No | Drop Down | Dynamic: fetched from ManagerPlus priorities API | | **Budget** | STRING | Yes | Drop Down | Dynamic: fetched from ManagerPlus budgets API | | **Work Type** | INTEGER | Yes | Drop Down | Dynamic: fetched from ManagerPlus work types API | | **Work Description** | STRING | Yes | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "purpose": "example-value", "budgetKey": "example-value", "workTypeKey": 1, "workDescription": "example-value", "priorityKey": "High" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Manager Plus platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Manager Plus system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Manager Plus API. # IBM Maximo (CF) Source: https://docs.kodelabs.com/products/integrations/work-orders/maximoCF Connect IBM Maximo (CF) to KODE OS for work orders, asset data > Connect IBM Maximo (CF) to KODE OS for work orders, asset data integration ## Overview Use this integration to connect IBM Maximo to KODE OS for work orders and asset data. You can discover devices and points, collect operational data with hybrid historical collection over REST, and use supported actions for maintenance and asset workflows. | Property | Value | | - | - | | **System Type** | Work Orders, Asset | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data * Discover Assets ## Prerequisites * An active account with IBM Maximo (CF) and access to their API or developer portal * API key or token from the IBM Maximo (CF) platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the IBM Maximo (CF) platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **IBM Maximo (CF)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Site ID** | Yes | text | The site identifier in the external system | | **Location ID** | Yes | text | The location identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the IBM Maximo (CF) system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in Cloud BMS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps IBM Maximo (CF) data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `workOrderId` | -- | | **woNumber** | `woNum` | -- | | **description** | `description` | -- | | **status** | `statusDescription` | -- | | **priority** | `woPriorityDescription` | -- | | **category** | `woClassify` | -- | | **floor** | `floor` | -- | | **createdBy** | `reportedBy` | -- | | **assignedTo** | `owner` | -- | | **createdAt** | `reportDate` | transformed | | **updatedAt** | `changeDate` | transformed | | **dueDate** | `targCompDate` | transformed | | **startedAt** | `actStart` | transformed | | **completedAt** | `actFinish` | transformed | | **estimatedCost** | `actLabCost` | -- | | **assetId** | `assetNum` | -- | | **externalUrl** | `href` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) * **Asset** -- Default polling: 1 days (min: 1 days, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions This integration supports actions that allow you to send commands to the IBM Maximo (CF) system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the IBM Maximo (CF) platform. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the IBM Maximo (CF) system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the IBM Maximo (CF) API. # IBM Maximo (FDH) Source: https://docs.kodelabs.com/products/integrations/work-orders/maximoFDH Connect IBM Maximo (FDH) to KODE OS for work orders data > Connect IBM Maximo (FDH) to KODE OS for work orders data integration ## Overview Use this integration to connect IBM Maximo (FDH) to KODE OS. You can pull work order and related operational data over REST with snapshot collection into your building Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Pull | | **Collection Mode** | SNAPSHOT | See [IBM Maximo (FDH)](https://kodelabs.com/integration/maximo-fdh/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with IBM Maximo (FDH) and access to their API or developer portal * API key or token from the IBM Maximo (FDH) platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the IBM Maximo (FDH) platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **IBM Maximo (FDH)** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **External URL** | Yes | text | An additional external URL for the integration | | **Username** | Yes | password | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps IBM Maximo (FDH) data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `wonum` | -- | | **title** | `wodesc` | -- | | **description** | mapped by connector | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **category** | `prioritydesc` | -- | | **subCategory** | `classficationdesc` | -- | | **location** | `(formatted)` | -- | | **floor** | `floorname` | -- | | **assignedTo** | `wo_assigned_to` | -- | | **createdAt** | `wocreatedate` | transformed | | **updatedAt** | `changedate` | transformed | | **dueDate** | `schedfinish` | transformed | | **startedAt** | `actstart` | transformed | | **completedAt** | `actfinish` | transformed | | **assetId** | `equipmentid` | -- | | **assetName** | `equipmentdesc` | -- | ### Polling Schedule * **WorkOrder** -- Default polling: 3 minutes (min: 3 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the IBM Maximo (FDH) platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the IBM Maximo (FDH) API. # NCMMS Source: https://docs.kodelabs.com/products/integrations/work-orders/ncmms Connect NCMMS to KODE OS for work orders data > Connect NCMMS to KODE OS for work orders data integration ## Overview Use this integration to connect NCMMS to KODE OS. You can collect work order data over REST with hybrid snapshot collection, ingest historical and multi-entity histories where configured, and use supported connector actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data ## Prerequisites * An active account with NCMMS and access to their API or developer portal * API key or token from the NCMMS platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the NCMMS platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **NCMMS** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Organization ID** | Yes | text | The organization ID in the vendor's API | | **Site ID** | Yes | text | The site identifier in the external system | | **GSA Address Code** | Yes | text | Configuration field for GSA Address Code | | **API Key** | Yes | password | The API key for authenticating with the external system | | **Collect Days Back** | Yes | number | Configuration field for Collect Days Back | ## What Data You Get ### GSA Work Orders Government Services Administration work order records ### Polling Schedule * **GsaWorkOrder** -- Default polling: 10 minutes (min: 10 minutes, max: 1 hours) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions This integration supports actions that allow you to send commands to the NCMMS system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the NCMMS platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the NCMMS API. # Nuvolo Source: https://docs.kodelabs.com/products/integrations/work-orders/nuvolo Connect Nuvolo to KODE OS for work orders data > Connect Nuvolo to KODE OS for work orders data integration ## Overview Use this integration to connect Nuvolo to KODE OS. You can collect work order and workplace operational data with hybrid historical collection over REST and use supported actions to align facilities work across your sites. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | See [Nuvolo](https://kodelabs.com/integration/nuvolo/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with Nuvolo and access to their API or developer portal * Username and password credentials for the Nuvolo system * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Nuvolo** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Room** | No | text | The specific room this connector is associated with | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Nuvolo data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `workOrderId` | -- | | **title** | `title` | -- | | **description** | `description` | -- | | **status** | `state` | -- | | **priority** | `priority` | -- | | **category** | `work_order_type` | -- | | **location** | `location` | -- | | **createdBy** | `created_by` | -- | | **assignedTo** | `assigned_to` | -- | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **startedAt** | mapped by connector | -- | | **completedAt** | mapped by connector | -- | | **assignmentGroup** | `assignmentGroup` | -- | | **serviceProvider** | `service_provider` | -- | | **problemCause** | `problem_cause` | -- | | **resolutionDetails** | `resolution_detail` | -- | | **estimatedCost** | `estimated_cost` | -- | | **lastComment** | `comments` | -- | | **assetName** | `asset` | -- | | **assetType** | `assetType` | -- | ### Polling Schedule * **WorkOrder** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in Nuvolo | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Short Description** | STRING | Yes | Text Box | -- | | **Description** | STRING | Yes | Text Box | -- | | **Priority** | STRING | Yes | Text Box | -- | | **Asset Location** | STRING | Yes | Text Box | -- | | **Asset Tag** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "short_description": "example-value", "description": "example-value", "priority": "High", "asset_location": "example-value", "asset_tag": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Verify the username and password are correct and the account has not been locked in the Nuvolo system. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Nuvolo API. # Open Fasap Source: https://docs.kodelabs.com/products/integrations/work-orders/openfasap Connect Open Fasap to KODE OS for work orders data > Connect Open Fasap to KODE OS for work orders data integration ## Overview Use this integration to connect Open Fasap to KODE OS. You can collect sensor and non-sensor work order data over REST with hybrid snapshot collection and use supported connector actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with Open Fasap and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Open Fasap developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Open Fasap developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Open Fasap** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Username** | Yes | password | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Site ID** | Yes | password | The site identifier in the external system | | **API Building ID** | Yes | password | The building or source identifier in the external system | | **Contract ID** | Yes | password | The contract identifier in the external system | | **Contract Number** | Yes | password | The contract or service agreement number | ## Devices and Points | Point | Display Name | | - | - | | `New` | New | | `FM_Criticity__c` | FM Criticity c | | `FM_Comment__c` | FM Comment c | | `FM_StartDate__c` | FM StartDate c | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Open Fasap data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **woNumber** | `caseNumber` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | mapped by connector | -- | | **category** | `type` | -- | | **subCategory** | `object` | -- | | **location** | `location.name` | transformed | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `modifiedAt` | transformed | | **startedAt** | `startedAt` | transformed | | **lastComment** | `comment` | -- | | **assetName** | `asset.name` | transformed | | **customFields** | `(custom fields)` | custom fields object | | **id** | `id` | -- | | **woNumber** | `workOrderNumber` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | mapped by connector | -- | | **category** | `type` | -- | | **subCategory** | `subject` | -- | | **location** | `location.name` | transformed | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `updatedAt` | transformed | | **dueDate** | `dueDate` | transformed | | **completedAt** | `endedAt` | transformed | | **duration** | `completionTimeInMinutes` | -- | | **serviceProvider** | `serviceProvider` | -- | | **lastComment** | `lastComment` | -- | | **assetName** | `asset.name` | transformed | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 30 minutes (min: 30 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Case **Type:** Write Creates a new maintenance case in OpenFASAP | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Description** | STRING | Yes | Text Area | -- | | **Problem Cause** | STRING | Yes | Drop Down | Dynamic: fetched from OpenFASAP symptoms API | | **Location** | STRING | No | Drop Down | Dynamic: fetched from OpenFASAP sites/buildings API | | **Equipment** | STRING | No | Drop Down | Dynamic: fetched from OpenFASAP equipments API | | **Type** | STRING | Yes | Drop Down | Static: type options | | **Priority** | STRING | Yes | Drop Down | Static: priority options | | **Comment** | STRING | No | Text Area | -- | | **Start Date** | DATE\_TIME | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "description": "example-value", "problemCause": "example-value", "type": "type options", "priority": "priority options", "location": "example-value", "equipment": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Open Fasap developer portal. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Open Fasap API. # Prism Source: https://docs.kodelabs.com/products/integrations/work-orders/prism Connect Prism to KODE OS for work orders data > Connect Prism to KODE OS for work orders data integration ## Overview Use this integration to connect Prism (Building Engines) to KODE OS. You can sync work orders, photos, and task updates with hybrid collection—including historical data where enabled—and use supported actions from Data Sources. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Prism](https://kodelabs.com/integration/prism/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data * Collect Historical Data ## Prerequisites * An active account with Prism and access to their API or developer portal * KODE OS environment with access to Data Sources ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Prism** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Tenant Account ID** | No | password | The tenant account identifier in the external system | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Prism data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `inspectionId` | -- | | **title** | `identifier` | -- | | **description** | `inspectionTypeName` | -- | | **status** | `status` | -- | | **assignedTo** | mapped by connector | transformed | | **assignmentGroup** | `teamAssignee.name` | transformed | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **dueDate** | mapped by connector | -- | | **completedAt** | mapped by connector | -- | | **externalUrl** | `url` | -- | | **customFields** | `(custom fields)` | custom fields object | | **id** | `id` | -- | | **title** | `identifier` | -- | | **description** | `name` | -- | | **status** | `status` | -- | | **assignedTo** | mapped by connector | transformed | | **assignmentGroup** | `team_assignee.name` | transformed | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **dueDate** | mapped by connector | -- | | **completedAt** | mapped by connector | -- | | **serviceProvider** | `organization_assignee.name` | transformed | | **estimatedCost** | `total_cost + total_cost_currency` | -- | | **duration** | mapped by connector | -- | | **customFields** | `(custom fields)` | custom fields object | | **location** | `equipment.location_details` | -- | | **floor** | `equipment.floor` | -- | | **assetId** | `equipment.id` | -- | | **assetName** | `equipment.identifier` | -- | | **assetType** | `equipment` | transformed | | **location** | `equipment.location_details` | conditional | | **id** | `id` | -- | | **title** | `identifier` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **location** | `locationDetails` | -- | | **floor** | `floor` | -- | | **createdBy** | `createdBy.email` | transformed | | **assignedTo** | mapped by connector | transformed | | **assignmentGroup** | `teamAssignee.name` | transformed | | **createdAt** | mapped by connector | -- | | **updatedAt** | mapped by connector | -- | | **dueDate** | mapped by connector | -- | | **completedAt** | mapped by connector | -- | | **duration** | `actualLaborHours` | -- | | **estimatedCost** | `totalCost` | -- | | **assetId** | `equipmentId` | -- | | **externalUrl** | `baseUrl` | -- | | **customFields** | `(custom fields)` | custom fields object | | **category** | `issueType.issueCategory` | -- | | **subCategory** | `issueType.name` | -- | | **category** | `issueType.issueCategory` | conditional | ### Polling Schedule * **WorkOrder** -- Default polling: 10 minutes (min: 10 minutes, max: 1 days) * **Inspections** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in Prism | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Issue Type** | STRING | Yes | Drop Down | Dynamic: fetched from Prism issue types API | | **Space** | STRING | Yes | Drop Down | Dynamic: fetched from Prism floors/spaces API | | **Description** | STRING | Yes | Text Area | -- | | **Location Details** | STRING | No | Text Area | -- | | **Image URL** | STRING | No | Text Area | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "issue_type_id": "12345", "space_id": "12345", "description": "example-value", "location_details": "example-value", "url": "https://example.com/resource" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation ### Cancel Work Order **Type:** Write Cancels an existing work order in Prism | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Work Order ID** | STRING | Yes | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "work_order_id": "12345" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Double-check all credential fields match the values from the Prism platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Prism API. # QR Connect Source: https://docs.kodelabs.com/products/integrations/work-orders/qrConnect Connect QR Connect to KODE OS for work orders data > Connect QR Connect to KODE OS for work orders data integration ## Overview Use this integration to connect QR Connect to KODE OS. You can combine REST and webhooks to capture work orders triggered by your configured events, keep snapshot data current, and use supported actions from KODE OS. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [QR Connect](https://kodelabs.com/integration/qr-connect/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with QR Connect and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the QR Connect developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the QR Connect developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the QR Connect platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **QR Connect** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **API Building ID** | Yes | text | The building or source identifier in the external system | | **API Building Name** | Yes | text | Configuration field for API Building Name | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps QR Connect data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `eventGuid` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **category** | `categoryName` | -- | | **subCategory** | `subcategoryName` | -- | | **location** | `location` | -- | | **assignedTo** | `assignedMember` | -- | | **assignmentGroup** | `assignedTeam` | -- | | **completedAt** | mapped by connector | transformed | | **duration** | `completionTime` | -- | | **lastComment** | `notes` | -- | | **customFields** | `noOfWorkOrders` | -- | ### Polling Schedule * **WorkOrder** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in QR Connect | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Title** | STRING | Yes | Text Box | -- | | **Description** | STRING | Yes | Text Box | -- | | **Category** | STRING | Yes | Drop Down | Static: predefined categories | | **Subcategory** | STRING | Yes | Drop Down | Static: predefined subcategories | | **Location** | STRING | Yes | Text Box | -- | | **Device Link** | STRING | Yes | Text Box | -- | | **Priority** | STRING | Yes | Text Box | Smart Device Priority | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "title": "example-value", "description": "example-value", "categoryGuid": "predefined categories", "subcategoryGuid": "predefined subcategories", "location": "example-value", "deviceLink": "example-value", "priority": "High" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the QR Connect developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the QR Connect platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the QR Connect system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the QR Connect API. # Service Channel Source: https://docs.kodelabs.com/products/integrations/work-orders/serviceChannel Connect Service Channel to KODE OS for work orders data > Connect Service Channel to KODE OS for work orders data integration ## Overview Use this integration to connect Service Channel to KODE OS. You can discover assets as devices, sync work orders on a snapshot poll, and create work orders from KODE OS workflows and automations. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data * Create Work Orders ## Prerequisites * A Service Channel account with API access * OAuth client credentials (Client ID and Client Secret) from Service Channel * Username, password, and user type (Provider or Subscriber) * Store ID for the site (and Subscriber ID when the user type is Provider) * KODE OS environment with access to Data Sources Typical Service Channel hosts: | Environment | URL | Auth URL | | - | - | - | | Sandbox | `https://sb2api.servicechannel.com` | `https://sb2login.servicechannel.com` | | Production | `https://api.servicechannel.com` | `https://login.servicechannel.com` | ## Generate API Credentials 1. Log in to the Service Channel developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID**, **Client Secret**, and **Auth URL** for OAuth token exchange ## Configure Connector in KODE OS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Service Channel** 3. Click **+ Add Datasource** 4. Fill in the fields below and validate credentials. Then select the store and subscriber, or type those IDs if the lists do not load. | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | Service Channel API URL (sandbox or production) | | **Auth URL** | Yes | text | Service Channel OAuth token URL | | **Username** | Yes | text | Service Channel username | | **Password** | Yes | password | Service Channel password | | **User Type** | Yes | dropdown | `Provider` or `Subscriber` for the username above | | **Client ID** | Yes | password | OAuth client ID | | **Client Secret** | Yes | password | OAuth client secret | | **Store ID** | Yes | dropdown or text | Drop-down when stores are returned. Text box when the store list is empty. | | **Subscriber ID** | Conditional | dropdown or text | Drop-down filtered by `Store ID` when stores are returned. Required for a Provider user. Text box when the store list is empty. | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query Service Channel and return available devices and points. Review the discovered items and select the devices you want to register in KODE OS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Service Channel, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `connection_status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | ## What Data You Get ### Point History Time-series `connection_status` readings from discovered devices. ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates. KODE OS maps Service Channel data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **woNumber** | `number` | -- | | **title** | `category` | -- | | **description** | `description` | -- | | **status** | `status.primary` | -- | | **priority** | `priority` | -- | | **category** | `trade` | -- | | **subCategory** | `problemCode` | -- | | **location** | `location.storeId` / `location.name` | Shown as Site in KODE OS | | **createdBy** | `createdBy` | -- | | **assignedTo** | `assignee.userName` | -- | | **createdAt** | `callDate` | -- | | **updatedAt** | `updatedDate` | -- | | **dueDate** | `scheduledDate` | -- | | **completedAt** | `completedDate` | -- | | **serviceProvider** | `provider.name` | -- | | **resolutionDetails** | `resolution` | -- | | **estimatedCost** | `nte` | -- | | **lastComment** | `notes.last.noteData` | -- | | **lastCommentBy** | `notes.last.createdBy` | -- | | **assetId** | `asset.id` | -- | | **assetType** | `asset.type` | -- | | **assetName** | `asset.tag` | -- | | **customFields** | labels, location, weather, cost | Includes city, region, state, weather event, and price when present | ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Service Channel Work Order **Type:** Write Creates a new work order in Service Channel. On create, KODE OS sends description as `area / problemType / equipment / problemCode / description`. Call date is set to the current date. Store ID comes from the linked device when you provide a device or point, otherwise from the connector. | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Category** | STRING | Yes | Drop down | Dynamic from Service Channel categories; text box if the lookup is empty | | **Priority** | STRING | Yes | Drop down | Dynamic from Service Channel priorities; text box if the lookup is empty | | **Description** | STRING | Yes | Text box | Free-text description appended after the issue-list path | | **NTE (Max Amount)** | STRING | Yes | Number | Default `0.00` | | **Area** | STRING | No | Drop down | Dynamic from Service Channel areas; parent of Problem Type | | **Problem Type** | STRING | No | Drop down | Depends on Area | | **Equipment** | STRING | No | Drop down | Depends on Problem Type | | **Problem Code** | STRING | No | Drop down | Depends on Equipment | | **Trade Name** | STRING | Yes | Drop down or text box | Always required. Dropdown of trades from discovered devices when available; otherwise a text box. If a linked device trade is present, that trade is the default | #### Linked versus unlinked create * **Linked to a device:** Provide a `device_id` or `point_id`. Store, subscriber, and provider come from that device. Trade uses the value on the form (defaulted from the device when KODE OS can match it). * **Not linked to a device:** Do not send `device_id` or `point_id`. Store comes from the connector. Subscriber comes from the connector when set. Provider is not set. Trade must be filled in on the form. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "category": "HVAC", "priority": "High", "description": "Unit not cooling", "nte": "0.00", "areaId": "Lobby", "problemType": "Temperature", "equipment": "AHU", "problemCode": "No cooling", "trade": "HVAC" } ``` #### Expected Result * KODE OS sends the action to Service Channel using the configured connector credentials * Service Channel returns success and creates the work order For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from Service Channel * Create work orders from KODE OS with category, priority, trade, and cascaded issue-list fields * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify URL, Auth URL, username, password, Client ID, and Client Secret. Confirm **User Type** matches the account. If the user type is Provider, Subscriber ID is required. > [accordion] Store or subscriber dropdown is empty > > Validate credentials first so KODE OS can load store and subscriber options from Service Channel. If the list still does not load, type the Store ID and, for a Provider user, the Subscriber ID. > [accordion] Discovery returns no devices > > Verify the connector credentials can list assets for the selected store. Run a test connection, then discover again. > [accordion] Create work order fails > > Trade Name is always required. Category, Priority, Description, and NTE are required. If you use Area, Problem Type, Equipment, and Problem Code, fill them in order. For an unlinked create, do not send a device or point id. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Service Channel API. # Service Channel Source: https://docs.kodelabs.com/products/integrations/work-orders/serviceChannelLowes Connect Service Channel to KODE OS for work orders data > Connect Service Channel to KODE OS for work orders data integration ## Overview Use this integration to connect Service Channel to KODE OS. You can discover devices and points, sync work order data with hybrid snapshot collection, create work orders from KODE OS workflows and automations, and use supported connector actions where enabled. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | ## Supported Capabilities * Discover Devices & Points * Collect Non-Sensor Data * Collect Historical Data * Collect Historical Multi-Entity Data ## Prerequisites * An active account with Service Channel and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Service Channel developer portal * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Service Channel developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in KODE OS 5. Note the **Auth URL** for OAuth token exchange ## Configure Connector in KODE OS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Service Channel** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Auth URL** | Yes | text | The OAuth authorization URL for token exchange | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Store ID** | Yes | text | The store identifier in the external system | ## Discover Devices and Points After configuring the connector, click **Discover** on the connector detail page. KODE OS will query the Service Channel system and return a list of available devices and their data points. Review the discovered items and select the devices you want to register in KODE OS. For more details on the discovery process, see the [Discovery guide](/products/integrations/capabilities/discovery). ## Devices and Points When you discover devices from Service Channel, KODE OS maps them to the following device types and data points: ### Connected Device Canonical Type: `default` | # | Point | Description | Unit | Writable | Collection | | - | - | - | - | - | - | | 1 | `connection_status` | **True** -- device is connected / **False** -- device is disconnected | -- | No | Polling | ## What Data You Get ### Point History Time-series readings including connection\_status, collected at regular intervals from connected devices ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Service Channel data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **woNumber** | `number` | -- | | **title** | `category` | -- | | **description** | `description` | -- | | **status** | `status.primary` | transformed | | **priority** | `priority` | -- | | **category** | `trade` | -- | | **subCategory** | `problemCode` | -- | | **location** | `(formatted location)` | -- | | **createdBy** | `createdBy` | -- | | **assignedTo** | `assignee.userName` | transformed | | **createdAt** | `callDate` | transformed | | **updatedAt** | `updatedDate` | transformed | | **dueDate** | `scheduledDate` | transformed | | **completedAt** | `completedDate` | transformed | | **serviceProvider** | `provider.name` | transformed | | **resolutionDetails** | `resolution` | -- | | **estimatedCost** | `nte` | -- | | **externalUrl** | `id` | -- | | **customFields** | `(custom fields)` | custom fields object | | **lastComment** | `notes.last.noteData` | -- | | **lastCommentBy** | `notes.last.createdBy` | -- | | **assetId** | `asset.id` | -- | | **assetType** | `asset.type` | -- | | **assetName** | `asset.tag` | -- | | **lastComment** | `notes.last.noteData` | conditional | | **assetId** | `asset.id` | conditional | ### Polling Schedule * **Point History** -- Default polling: 15 minutes (min: 15 minutes, max: 1 hours) * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Service Channel Work Order **Type:** Write Creates a work order in Service Channel (Lowes) with status `Open`. `ScheduledDate` is not a form field. KODE OS sets it from the created time plus the maximum hours for the selected priority. | Priority | Maximum hours | | - | - | | `P1 Emergency (6 Hours)` | 6 | | `P2 High (6-48 Hours)` | 48 | | `P3 Medium (Under 1 Week)` | 168 | | `P4 Low (Under 2 Weeks)` | 336 | When the event is linked to a device, `Description` is filled and locked. It starts with the asset tag, then the event name, KODE event ID, description, and URL. The asset tag is the last segment of the device display name. `AssetId` is sent from that device and is not a form field. `Trade Name` is locked to the linked trade. When the event is not linked, `Description` is an editable text box, `Location` and `Trade Name` are drop-downs, and `Provider` is filtered by the selected trade. `Problem Type` loads from the retail facilities issue list. `Asset Type` depends on the selected location and problem. | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Location** | STRING | Yes | Drop Down | Locations for the connector | | **Category** | STRING | Yes | Drop Down | `REPAIR - REACTIVE` | | **Problem Code** | STRING | Yes | Drop Down | `KODE FDD` | | **Priority** | STRING | Yes | Drop Down | The four priorities above. A linked event defaults to the FDD priority. | | **NTE (Max Amount)** | STRING | Yes | Number | `0.00` | | **Description** | STRING | Yes | Text Box | Locked when the event is linked to a device | | **Trade Name** | STRING | Yes | Text Box or Drop Down | Locked text when linked. Drop-down filtered by location when not linked. | | **Provider** | STRING | No | Drop Down | Filtered by trade when the event is not linked | | **Problem Type** | STRING | Yes | Drop Down | Depends on `Location` | | **Asset Type** | STRING | Yes | Drop Down | Depends on `Problem Type` | #### Expected Result * KODE OS creates the work order in Service Channel (Lowes) with status `Open` * `Problem Code` on the new work order is `KODE FDD` For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Service Channel developer portal. > [accordion] Discovery returns no devices > > Verify the connector credentials have sufficient permissions in the Service Channel system to list devices. Run a test connection first to confirm connectivity. Some systems require specific API scopes or roles for device discovery. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Service Channel API. # Service Now Source: https://docs.kodelabs.com/products/integrations/work-orders/serviceNow Connect Service Now to KODE OS for work orders data > Connect Service Now to KODE OS for work orders data integration ## Overview Use this integration to connect ServiceNow to KODE OS. You can ingest tickets and work order data over REST and webhooks with hybrid snapshot collection so IT and facilities work stays visible next to your building data. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | SNAPSHOT | | **Actions** | Supported | See [Service Now](https://kodelabs.com/integration/service-now/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data * Receive Webhook Data ## Prerequisites * An active account with Service Now and access to their API or developer portal * OAuth client credentials (Client ID and Client Secret) from the Service Now developer portal * KODE OS environment with access to Data Sources ### Vendor Onboarding References Use these official vendor resources to verify API access, credentials, and permission prerequisites: * [ServiceNow REST authentication](https://www.servicenow.com/docs/r/platform-security/authentication/api-key-and-hmac-rest-apis.html) * [ServiceNow basic auth examples](https://www.servicenow.com/docs/r/api-reference/web-services/r_BasicAuthenticationExamples.html) ## Generate API Credentials 1. Log in to the Service Now developer portal or admin console 2. Navigate to the API or developer settings section 3. Create a new API application or client 4. Note the **Client ID** and **Client Secret** -- you will need these when configuring the connector in Cloud BMS ## Configure Webhook This integration uses webhooks for real-time data delivery. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Service Now platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Service Now** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **Username** | Yes | text | The username for authenticating with the external system | | **Password** | Yes | password | The password for authenticating with the external system | | **Client ID** | Yes | password | The OAuth client ID from the vendor's developer portal | | **Client Secret** | Yes | password | The OAuth client secret from the vendor's developer portal | | **Assignment Group ID** | Yes | text | The assignment group identifier for routing work orders | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Service Now data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **title** | `title` | -- | | **description** | `description` | -- | | **status** | `status` | -- | | **priority** | `priority` | -- | | **category** | `category` | -- | | **location** | `location` | -- | | **createdBy** | `createdBy` | -- | | **assignedTo** | `assignedTo` | -- | | **assignmentGroup** | `assignmentGroup` | -- | | **createdAt** | `createdAt` | -- | | **updatedAt** | `updatedAt` | -- | | **dueDate** | `dueDate` | -- | | **resolutionDetails** | `resolutionDetails` | -- | | **lastComment** | `lastComment` | -- | | **externalUrl** | `url` | -- | ### Polling Schedule * **WorkOrder** For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new work order in ServiceNow | Field | Type | Required | Input | Options / Default | | - | - | - | - | - | | **Priority** | STRING | Yes | Drop Down | Static: priority options | | **Category** | STRING | Yes | Drop Down | Dynamic: fetched from ServiceNow categories | | **Location** | STRING | Yes | Text Area | -- | | **Description** | STRING | Yes | Text Box | -- | | **Due Date** | DATE\_TIME | No | Text Box | -- | | **Assigned To** | STRING | No | Text Box | -- | | **KODE Work Order Link** | URL | No | Text Box | -- | #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "priority": "priority options", "category": "example-value", "location": "example-value", "description": "example-value", "due_date": "2026-03-29T10:00:00Z", "assigned_to": "example-value" } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the Client ID and Client Secret match the values from the Service Now developer portal. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Service Now platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Service Now system can reach the KODE OS webhook endpoint over the network. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Service Now API. # Vantify Source: https://docs.kodelabs.com/products/integrations/work-orders/vantify Connect Vantify to KODE OS for work order management, events, and webhook notifications > Connect Vantify to KODE OS for work orders data integration ## Overview Use this integration to connect Vantify to KODE OS for facilities maintenance and work orders. You can poll work orders over REST, receive real-time updates through webhooks with historical collection, and create work orders from the KODE OS dashboard when actions are enabled. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST + Webhook | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | ## Supported Capabilities * Collect Non-Sensor Data (Work Orders) * Receive Webhook Events * Create Work Orders (Action) ## Prerequisites * An active Vantify account with API access * Username and password credentials for the Vantify platform * The Vantify Site ID for the building you want to connect * KODE OS environment with access to Data Sources ## Configure Webhook This integration uses webhooks for real-time event notifications. After creating the connector in KODE OS: 1. Copy the webhook URL provided on the connector detail page 2. In the Vantify platform, navigate to the webhook or notification settings 3. Add a new webhook endpoint using the KODE OS URL 4. Configure the authentication header as specified on the connector detail page 5. Save and enable the webhook > [!NOTE] > > Vantify supports these webhook event types: `job_created`, `job_message`, `job_alarm_updated`, `job_operation_completed`, `job_operation_commenced`, `job_approval_requested`, `job_approval_accepted`, `job_assignment_requested`, `job_contact_updated`, `job_operation_acknowledged`, `job_assignment_reassigned`, `job_file_created`, `job_operation_cancelled`, `job_operation_reopened`, `job_proposal_requested` ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Vantify** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **Connector Name** | Yes | text | Display name for this connector | | **URL** | Yes | text | Base URL of the Vantify API server | | **Username** | Yes | text | Vantify login username | | **Password** | Yes | password | Vantify login password (encrypted) | | **Site ID** | Yes | text | The Vantify site identifier for the building | ## What Data You Get ### Work Orders Work orders are polled every 15 minutes from the Vantify Jobs API. Each work order is mapped to the KODE OS standard format: | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | `id` | `id` | Unique job identifier | | 2 | `summary` | `title` | Work order title | | 3 | `description` | `description` | Detailed description | | 4 | `type` | `type` | Job type | | 5 | `status` | `status` | Current status | | 6 | `createdAt` | `created_at` | Job creation timestamp | | 7 | `completionDueAt` | `due_date` | Due date for completion | | 8 | `lastModified` | `updated_at` | Last modification timestamp | | 9 | `serviceProviderName` | `service_provider` | Assigned service provider | | 10 | `_links.site.id` | `api_building_id` | Vantify site reference | | 11 | `_links.site.title` | `api_building_name` | Site name | | 12 | `_links.site.address` | `location` | Site address | | 13 | `_embedded.jobgroup.name` | `assignment_group` | Assignment group | | 14 | `_embedded.priority.name` | `priority` | Priority level | ### Events Webhook-driven events are captured in real time and mapped to the KODE OS Event model: | # | Source Field | KODE Field | Notes | | - | - | - | - | | 1 | `id` | `id` | Fallback: `uniqueId`, then composite key | | 2 | `type` | `name` | Webhook event type (e.g., `job_created`) | | 3 | `note` / `body` / `description` | `description` | Fallback order; for `job_message`: author info prepended | | 4 | (fixed) | `type` | Always "Event" | | 5 | (fixed) | `category` | Always "WorkOrder" | | 6 | `extraData.location.name` | `location` | Parent and child location names | | 7 | `createdAt` | `createdAtUtc` | Event timestamp | | 8 | `externalId` | custom: `job_id` | Related job identifier | | 9 | `client` | custom: `client` | Client name | | 10 | `userDetails` | custom: `user_details` | User name and email pairs | ### Polling Schedule * **Work Orders** -- REST poll every 15 minutes (min: 15 minutes, max: 1 hour) * **Events** -- Real-time via webhook (no polling) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions ### Create Work Order **Type:** Write Creates a new reactive work order in the Vantify system. The Site ID is automatically inherited from the connector configuration. | Field | Type | Required | Input | Notes | | - | - | - | - | - | | **Title** | STRING | Yes | Text Box | Work order summary | | **Description** | STRING | Yes | Text Area | Detailed description | | **Assignment Group** | STRING | Yes | Drop Down | Dynamic list from Vantify active job groups | | **Service Provider** | STRING | Yes | Drop Down | Dynamic list from Vantify active service providers | | **Priority** | STRING | Yes | Drop Down | Dynamic list from Vantify priority levels | > [!NOTE] > > New work orders are always created as **reactive** type with an initial status of **assignment\_pending**. The site ID is automatically set from the connector configuration. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "summary": "AHU-3 high discharge temperature alarm", "description": "Create technician dispatch to inspect AHU-3 and verify cooling valve operation.", "jobGroup": "HVAC", "serviceProvider": "Preferred HVAC Vendor", "priority": "High" } ``` #### Expected Result * KODE OS sends the action to the Vantify Jobs API using the configured connector credentials * Vantify creates a new reactive work order with status `assignment_pending` and returns a success response For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from the Vantify CAFM platform * Create reactive work orders directly from KODE OS when issues are detected by sensors or alarms * Receive real-time webhook notifications for work order lifecycle events (created, assigned, completed, cancelled) * Track maintenance KPIs including response time, completion rate, and service provider performance ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the username and password are correct and the account has not been locked. Check that the URL is reachable from the KODE OS environment. Vantify uses JWT-based authentication -- the token is obtained from the `/auth` endpoint using your credentials. > [accordion] Webhook data not arriving > > Verify the webhook URL is correctly registered in the Vantify platform. Check that the authentication header matches the value from the KODE OS connector detail page. Ensure the Vantify system can reach the KODE OS webhook endpoint over the network. > [accordion] Work orders not syncing > > Verify the Site ID in the connector configuration matches the Vantify site you want to monitor. Check that the credentials have permission to access the Jobs API for that site. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired passwords, network changes, or the Vantify API being temporarily unavailable. # Visitt Source: https://docs.kodelabs.com/products/integrations/work-orders/visitt Connect Visitt to KODE OS for work orders data > Connect Visitt to KODE OS for work orders data integration ## Overview Use this integration to connect Visitt to KODE OS. You can pull buildings, locations, tenants, reviews, and work order data over REST with hybrid historical collection and use supported actions to coordinate property operations. | Property | Value | | - | - | | **System Type** | Work Orders | | **Communication** | REST | | **Collection** | Hybrid (Pull + Push) | | **Collection Mode** | HISTORICAL | | **Actions** | Supported | See [Visitt](https://kodelabs.com/integration/visitt/) on the KODE Labs Integrations Library. ## Supported Capabilities * Collect Non-Sensor Data ## Prerequisites * An active account with Visitt and access to their API or developer portal * API key or token from the Visitt platform * KODE OS environment with access to Data Sources ## Generate API Credentials 1. Log in to the Visitt platform or admin console 2. Navigate to the API settings, developer section, or account settings 3. Generate a new API key or token 4. Copy the key and store it securely -- you will need it when configuring the connector in Cloud BMS ## Configure Connector in Cloud BMS 1. Navigate to **Data Sources** in your building 2. Click **API Catalog** and search for **Visitt** 3. Click **+ Add Datasource** 4. Fill in the fields below and complete the three-page setup flow | Field | Required | Type | Description | | - | - | - | - | | **URL** | Yes | text | The base URL or IP address of the external system | | **API Key** | Yes | password | The API key for authenticating with the external system | | **API Building ID** | Yes | text | The building or source identifier in the external system | ## What Data You Get ### Work Orders Maintenance and service requests including title, description, status, priority, assignee, due dates, vendor response, resolution details, and cost estimates KODE OS maps Visitt data to these standard fields: | KODE Field | Source Field | Notes | | - | - | - | | **id** | `id` | -- | | **title** | `type` | -- | | **description** | `description` | -- | | **status** | mapped by connector | -- | | **priority** | mapped by connector | -- | | **category** | `category.name` | transformed | | **subCategory** | `subCategory.name` | transformed | | **location** | `site` | transformed | | **assignedTo** | `assignedUsers.get` | transformed | | **createdAt** | `createdAt` | transformed | | **updatedAt** | `updatedAt` | transformed | | **dueDate** | `dueDate` | transformed | | **completedAt** | `completedAt` | transformed | | **serviceProvider** | `completedByActor.label` | transformed | | **estimatedCost** | `totalCharge` | -- | | **customFields** | `(custom fields)` | custom fields object | ### Polling Schedule * **WorkOrder** -- Default polling: 15 minutes (min: 15 minutes, max: 1 days) For more details on collection modes, see the [Data Collection guide](/products/integrations/capabilities/data-collection). ## Available Actions This integration supports actions that allow you to send commands to the Visitt system. Available actions are displayed on the device or entity detail page in KODE OS. #### Example Request ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "action": "ActionName", "target": "entity-or-device-id", "parameters": {} } ``` #### Expected Result * KODE OS sends the action to the external API using the configured connector credentials * The external system returns success (typically HTTP 2xx) and processes the requested operation For more details on how actions work, see the [Actions guide](/products/integrations/capabilities/actions). ## Use Cases Once connected, this integration enables you to: * Centralize maintenance requests and work order status from facility management systems * Create and update work orders directly from KODE OS when issues are detected * Track maintenance KPIs including response time, completion rate, and cost ## Troubleshooting > [accordion] Authentication or connection error > > Verify that the credentials are correct and have not expired. Check that the URL is reachable from the KODE OS environment. Ensure the API key or token is valid and has not been revoked or expired in the Visitt platform. > [accordion] Data collection stops or gaps appear > > Check the connector status on the Data Sources page. If the status shows an error, review the error logs on the connector detail page. Common causes include expired credentials, network changes, or rate limiting by the Visitt API. # Invoke an action Source: https://docs.kodelabs.com/products/kode-api/api-reference/actions/invoke-an-action /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/actions/{action}/invoke Runs a data source action with the field values you provide. > [!NOTE] > > For the `DISCOVER` action, send the `devices` value as a JSON array encoded as a string. # List action fields Source: https://docs.kodelabs.com/products/kode-api/api-reference/actions/list-action-fields /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/actions/{action}/fields Returns the fields an action accepts. Use the response to build the request body for invoking the action. # List data source actions Source: https://docs.kodelabs.com/products/kode-api/api-reference/actions/list-data-source-actions /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/actions Returns the actions a data source supports, grouped by entity. # Create an access token Source: https://docs.kodelabs.com/products/kode-api/api-reference/authentication/create-an-access-token /openapi/kode-api.yaml post /token Exchanges a signed JWT client assertion for a Bearer access token. > [!NOTE] > > Create the `client_assertion` with the private key issued for your client ID. See [Authentication](/products/kode-api/authentication) for the full flow. # Get authorization server metadata Source: https://docs.kodelabs.com/products/kode-api/api-reference/authentication/get-authorization-server-metadata /openapi/kode-api.yaml get /.well-known/oauth-authorization-server Returns the OAuth 2.0 authorization server metadata. Use it to find the token endpoint and supported signing algorithms. # Revoke an access token Source: https://docs.kodelabs.com/products/kode-api/api-reference/authentication/revoke-an-access-token /openapi/kode-api.yaml post /revoke Invalidates an access token before it expires. # Create a building Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/create-a-building /openapi/kode-api.yaml post /api/v1/buildings Creates a building in your organization. The building starts unpublished, with no products enabled. > [!WARNING] > > This call creates a real building in your organization. The API has no endpoint to delete a building, and the name stays taken until someone removes the building in KODE OS. Test with a clearly named building, such as `API test building`, and ask your KODE project team to remove it when you are done. > [!NOTE] > > A new building has every product turned off. Until the `api` product is enabled for it, calls that name the building return `403`, including [Get a building](/products/kode-api/api-reference/buildings/get-a-building), [Create a KODE API connector](/products/kode-api/api-reference/connectors/create-a-kode-api-connector), and [Update a building](/products/kode-api/api-reference/buildings/update-a-building). The API cannot enable products. Your KODE project team enables the `api` product for a new building by hand, so ask them before you call the building, and allow for that step if you automate building creation. ## Required fields | Field | Rule | | - | - | | `name` | Up to 50 characters. Must be unique in your organization, ignoring case. | | `primaryFunction` | One of `Banking/financial services`, `Education`, `Entertainment/public assembly`, `Food sales and service`, `Healthcare`, `Lodging/residential`, `Manufacturing/industrial`, `Mixed use`, `Office`, `Parking`, `Public services`, `Religious worship`, `Retail`, `Technology/science`, `Services`, `Utility`, `Warehouse/storage`, or `Other`. The value is case-sensitive. | | `address` | An object with `address1`, `city`, `zip`, and `country`. `address2` (up to 100 characters) and `state` are optional. | | `baseTemp` | The base temperature as a number, in °F. | ## Optional fields | Field | Rule | | - | - | | `yearBuild` | A whole number from `1600` to `2100`. | | `area` | The building area in square feet. A whole number, `0` or more. | | `region`, `brand`, `zone`, `district`, `identifier` | Up to 255 characters each. `identifier` is your own building code. It does not have to be unique. | | `phoneNumber` | A phone number, for example `+16502530000`. | | `site` | An object with both `identifier` and `name` (up to 255 characters each). | ## What the API sets for you * The API looks up the `address` to find the building location. The response carries the location, the state and country codes, and the time zone `tz`. If the address cannot be located, the request fails with `400`. Check `address1`, `city`, `zip`, and `country`. * `published` is `false`. Use [Set the status of a building](/products/kode-api/api-reference/buildings/set-the-status-of-a-building) to change it. * `products` lists the products with `enabled` set to `false`, and the counts and `stats` start at `0`. Send `baseTemp` in °F whatever unit you use in KODE OS. # Get a building Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/get-a-building /openapi/kode-api.yaml get /api/v1/buildings/{buildingId} Returns one building, with its counts and the number of devices that are `ok` or `down`. > [!NOTE] > > The response answers `403` when the building does not exist, when it is not available to your service account, and when the `api` product is not enabled for it. The API does not say which, so a building id cannot be guessed. A building you just created answers `403` until the `api` product is enabled. See [Create a building](/products/kode-api/api-reference/buildings/create-a-building). The counts (`areasCount`, `devicesCount`, `connectorsCount`, `systemsCount`, and `pointsCount`) and `stats.devices` come from the building data in KODE OS. They are `0` for a building that has no data yet. [List buildings](/products/kode-api/api-reference/buildings/list-buildings) leaves `stats` empty. # Get a job Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/get-a-job /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/jobs/{jobId} Returns the status of a background job that an earlier request started in this building. Some requests finish in the background. They answer `202` with a job, and you read the job here until it ends. The requests that start a job are: * [Ingest devices through a connector](/products/kode-api/api-reference/connectors/ingest-devices-through-a-connector) * [Ingest points through a connector](/products/kode-api/api-reference/connectors/ingest-points-through-a-connector) * The device and point batch update and batch delete requests. Use the `_id` of the job from that response as `jobId`. Call this endpoint every few seconds until `status` is `COMPLETED` or `FAILED`. Every call counts toward your [rate limits](/products/kode-api/fundamentals#rate-limits). | `status` | Meaning | | - | - | | `PENDING` | The job is waiting to start. | | `PROCESSING` | The job is running. | | `COMPLETED` | The job finished. | | `FAILED` | The job stopped. `errorMessage` says why. | | `CANCELED` | The job was stopped before it finished. | | `PROCESSED` | The job is waiting for a follow-up step. Ingest jobs do not use this status. | > [!NOTE] > > A job reports only its status. It has no result for each item, and `COMPLETED` means the job ran to the end. After an ingest, read the devices and points back to confirm what was stored. A job belongs to the building that started it. Reading it under another building returns `404`. # List building areas Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/list-building-areas /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/areas Returns the areas defined for a building. # List buildings Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/list-buildings /openapi/kode-api.yaml get /api/v1/buildings Returns the buildings available to the authenticated service account. > [!TIP] > > Call this endpoint first to confirm that your token works and to get the `buildingId` values used by other endpoints. # Set the status of a building Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/set-the-status-of-a-building /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/status Sets a building to `PUBLISHED` or `UNPUBLISHED`. You can switch it back at any time. A new building is `UNPUBLISHED`. The building keeps this status in `published` (`true` for `PUBLISHED`) until you change it again. | `status` | Result | | - | - | | `PUBLISHED` | `published` is `true`. | | `UNPUBLISHED` | `published` is `false`. | The values are case-sensitive. Sending the status the building already has returns `409`, so a repeated call is not safe to treat as a no-op. The status does not delete any data. If your service account's role limits access to published buildings, an unpublished building returns `403` on reads, including [Get a building](/products/kode-api/api-reference/buildings/get-a-building) and [Get a job](/products/kode-api/api-reference/buildings/get-a-job). Publishing and unpublishing still work in that case. # Update a building Source: https://docs.kodelabs.com/products/kode-api/api-reference/buildings/update-a-building /openapi/kode-api.yaml put /api/v1/buildings/{buildingId} Changes the fields you send and keeps every other field as it is. > [!WARNING] > > This call changes a real building. Other apps and users in your organization see the change. You cannot clear a field through the API, so a value you set stays until you replace it with another value. The update is partial. Nothing is required. A field you leave out, send as `null`, or send as an empty string keeps its stored value. * `address` replaces the stored address as a whole. Send `address1`, `city`, `zip`, and `country` whenever you send `address`. The API looks up the new address again and updates the location and the time zone. * `site` replaces the stored site group. Send both `identifier` and `name`. * `name` must stay unique in your organization, ignoring case. * `baseTemp` is in °F and `area` is in square feet. * The API ignores `published`, `status`, `products`, `tags`, `picture`, and `tz` if you send them. To publish a building, use [Set the status of a building](/products/kode-api/api-reference/buildings/set-the-status-of-a-building). The limits are the same as in [Create a building](/products/kode-api/api-reference/buildings/create-a-building). # Create a KODE API connector Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/create-a-kode-api-connector /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/connectors/kode-api Creates a connector that receives devices and points you send through the API. The only input is `name`. KODE sets `integrationType` to `API_KODE`. Keep the `_id` from the response. You use it as `connectorId` in every other connector request. > [!NOTE] > > Names are free text. The API accepts a second connector with the same name in the same building, so call [List connectors](/products/kode-api/api-reference/connectors/list-connectors) first if you want to reuse one. Unknown properties in the body are ignored. A connector appears in KODE OS as a data source of the building. Its `_id` is the data source id that the data source endpoints use, for example in [Ingest device and point data](/products/kode-api/guides/ingest-device-data). The response does not include `entities`. [Get a connector](/products/kode-api/api-reference/connectors/get-a-connector) returns them. # Get a connector Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/get-a-connector /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/connectors/{connectorId} Returns one connector of a building, with the kinds of data it handles. `entities` lists the kinds of data the connector holds. A new KODE API connector reports `DEVICES` and `ASSETS`. This endpoint does not return the connection status. Use [Get connector status](/products/kode-api/api-reference/connectors/get-connector-status) for that. # Get connector status Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/get-connector-status /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/connectors/{connectorId}/status Returns the last connection status KODE OS recorded for a connector. The response holds `curStatus` and `time`, the last status value and when it was recorded. Common values are `ok` and `down`, but the value is free text, so do not depend on a fixed list. A connector that has never reported a status returns an empty object, `{}`. > [!NOTE] > > Ingesting devices or points does not change the status. To follow an ingest, read its job with [Get a job](/products/kode-api/api-reference/buildings/get-a-job). To check the result, list the devices and points of the building. # Ingest devices through a connector Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/ingest-devices-through-a-connector /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/connectors/{connectorId}/ingest/devices Adds devices to a KODE API connector, or updates devices you added before. The work runs as a background job. > [!NOTE] > > The request is checked first and then runs as a job. A `202` response means the job started, not that the devices exist yet. Read the job with [Get a job](/products/kode-api/api-reference/buildings/get-a-job) until `status` is `COMPLETED`, then read the devices back. A job has no result for each item. Send 1 to 1,000 items in one request. Each item needs three members: | Member | Meaning | | - | - | | `deviceExternalId` | Your own stable identifier for the device. KODE uses it to recognize the device on later requests. | | `deviceExternalPath` | The path of the device in your system. | | `deviceName` | The name shown in KODE OS. | You can also send `deviceLocation`, a text description of where the device is. * Only KODE API connectors accept ingestion. A connector of another type returns `400`. * Send a `deviceExternalId` that exists already and the API updates the name and the location of that device. It does not create a second device. * The devices are created in the building and the connector in the path. A `buildingId` in the body is ignored. * Ingest devices before you ingest their points. See [Ingest points through a connector](/products/kode-api/api-reference/connectors/ingest-points-through-a-connector). # Ingest points through a connector Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/ingest-points-through-a-connector /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/connectors/{connectorId}/ingest/points Adds points to devices you already ingested on a KODE API connector. The work runs as a background job. > [!NOTE] > > The request is checked first and then runs as a job. A `202` response means the job started, not that the points exist yet. Read the job with [Get a job](/products/kode-api/api-reference/buildings/get-a-job) until `status` is `COMPLETED`, then read the points back. A job has no result for each item. Send 1 to 1,000 items in one request. Each item describes one point and the device it belongs to. | Member | Meaning | | - | - | | `deviceExternalId`, `deviceExternalPath` | The `deviceExternalId` and `deviceExternalPath` you sent when you ingested the parent device. Required. | | `pointExternalId` | Your own stable identifier for the point. Required. | | `pointExternalPath` | The path of the point in your system. Required. | | `pointName` | The name shown in KODE OS. Required, up to 255 characters. | | `pointKind` | `Number`, `Str`, or `Bool`. Required. The value is case-sensitive. | | `pointUnit` | The `_id` of an ontology unit, for a `Number` point. Optional. | | `pointEnum` | The allowed values as one comma-separated string, such as `off,on,auto`. Optional. | | `pointWritable` | `true` if the point accepts writes. Optional, `false` when you leave it out. | | `pointMinVal`, `pointMaxVal` | The lowest and highest value, as numbers. Optional. `pointMinVal` cannot be higher than `pointMaxVal`. | The request returns `400` before any job starts when: * A parent device was not ingested on this connector. The message lists the missing `deviceExternalId` values. * A `pointUnit` is not an ontology unit. The message lists the unknown ids. * A `pointKind` is not `Number`, `Str`, or `Bool`. * A point has `pointMinVal` higher than `pointMaxVal`. * The connector is not a KODE API connector. Send a `pointExternalId` that exists already and the API does not create a second point. A `buildingId` in the body is ignored. # List connectors Source: https://docs.kodelabs.com/products/kode-api/api-reference/connectors/list-connectors /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/connectors Returns the connectors of a building, newest first. The list holds every connector in the building, not only those you created through the API. Connectors created with [Create a KODE API connector](/products/kode-api/api-reference/connectors/create-a-kode-api-connector) have `integrationType` set to `API_KODE`. Only those connectors accept ingested devices and points. The default order is the connector `_id`, newest first. Use `asc` or `dsc` with `name` to sort by name. # List building data sources Source: https://docs.kodelabs.com/products/kode-api/api-reference/data-sources/list-building-data-sources /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/datasources Returns the data sources connected to a building. # Add device references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/add-device-references /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/{deviceId}/references Links the device in the path to one or more other devices in the same building. The device in the path is the referrer. `relationship` describes the link: its `key`, whether it accepts several devices (`multi`), and its direction (`type`). Take the three values from [List connections for a canonical type](/products/kode-api/api-reference/ontology/list-connections-for-a-canonical-type), which returns each connection a device can have in exactly this shape. The link is stored on both devices. Each linked device holds the reverse link, with the opposite `type`. Both devices need an ontology applied, and the connection must be valid for them. The request is refused with `400` when: * A device would reference itself. * A listed device is already linked to the device in the path. * The link would create a loop, directly or through other devices, or reverse a link that already exists. * A device has no ontology. A successful request returns `204` with an empty body. Read the links back with [List device references](/products/kode-api/api-reference/devices/list-device-references) to confirm they were stored. # Add device space references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/add-device-space-references /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/{deviceId}/space-references Links the device in the path to one or more spaces in the same building. Send the `id` of each space in `referencedSpaceIds`. The server decides whether the device `serves` or `measures` each space. Repeating an id, or a space that is already linked, does not add a second link. The device needs an ontology applied. Without one, the request is refused with `400`. A successful request returns `204` with an empty body. Read the links back with [List device space references](/products/kode-api/api-reference/devices/list-device-space-references) to confirm they were stored. # Create or update a device Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/create-or-update-a-device /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices Creates a device and its points. If a device with the same `id` exists, KODE OS updates it instead. # Create or update devices in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/create-or-update-devices-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices/batch Creates or updates multiple devices and their points. Matching device and point identifiers update existing records. Other items create new records. # Delete a device Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/delete-a-device /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/devices/{deviceId} Permanently deletes a device together with its points and the links that other objects hold to it. > [!WARNING] > > A delete cannot be undone. It removes the device and everything listed here: > > * Every point of the device. The points are deleted, not moved. > * Every copy of those points on other devices, and every copy that sits on this device. > * Every device reference and space reference that other devices hold to this device. > > The point counts of devices that held a removed copy, and the device counts of the building and of the space the device was located in, are updated. See [Organize devices and points](/products/kode-api/guides/organize-devices-and-points#what-a-delete-removes). A virtual device is deleted the same way. Copies attached to it are deleted with it. A successful delete returns `204` with an empty body. Read the device with [Get a device](/products/kode-api/api-reference/devices/get-a-device) to confirm it is gone. It answers `404`. # Delete devices in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/delete-devices-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/batch-delete Starts a job that permanently deletes up to 1,000 devices and everything that depends on them. > [!WARNING] > > A delete cannot be undone. Each device is deleted with its points, the copies of those points, and the references other devices hold to it, exactly as with [Delete a device](/products/kode-api/api-reference/devices/delete-a-device). The delete runs as a job. Poll [Get a job](/products/kode-api/api-reference/buildings/get-a-job) with the job `_id` until `status` is `COMPLETED`, `FAILED` or `CANCELED`. > [!NOTE] > > Ids that do not match a device in this building are skipped, and the job still ends with `COMPLETED`. The job carries no per-device result. Read each device afterwards to confirm it is gone. # Get a device Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/get-a-device /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices/{deviceId} Returns one device in a building, with its current status and the number of points it holds. > [!NOTE] > > The response does not include `location` or the space the device is located in, even when you set them with [Update a device](/products/kode-api/api-reference/devices/update-a-device). # Get device status Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/get-device-status /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices/{deviceId}/status Returns the latest connectivity status of a device and when it was recorded. KODE OS derives the status. You do not send it. Values that you push to the points of a device, with an optional point `status`, are aggregated per device in 1-minute windows. The device is `down` when its points are down. KODE OS records one status for the device for each 1-minute window in which its points receive data, using the latest value in that window. `dateTime` is the time of that latest recorded status. It moves forward with new data even when the status stays the same. A device that never reported returns `200` with `status` and `dateTime` set to `null`. # List building devices Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/list-building-devices /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices Returns the devices in a building. # List device references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/list-device-references /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices/{deviceId}/references Returns the devices that this device is linked to, with the direction and key of each link. Each item names the linked device, the direction of the link as seen from the device in the path, the connection `key`, and the ontology of the linked device. A link is stored on both devices, with opposite directions. See [Organize devices and points](/products/kode-api/guides/organize-devices-and-points#link-devices-to-each-other). # List device space references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/list-device-space-references /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices/{deviceId}/space-references Returns the spaces that this device is linked to, with the kind of each link. Each item has the space and a `key`. The `key` is `serves` when the device serves the space and `measures` when it measures the space. The server decides the key; you do not send it. See [Organize devices and points](/products/kode-api/guides/organize-devices-and-points#link-a-device-to-spaces). # List device timeseries Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/list-device-timeseries /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/devices/{deviceId}/timeseries Returns the recorded statuses of a device between `from` and `to`, oldest first. Each row is one recorded status: KODE OS records one per 1-minute window in which the device's points receive data, so consecutive rows can carry the same status. To find when a device went down or came back, compare each row with the one before it. > [!NOTE] > > The range between `from` and `to` has the same day limit as [List point timeseries](/products/kode-api/api-reference/timeseries/list-point-timeseries). Split longer ranges into multiple requests. Both bounds are inclusive. `from` and `to` need a UTC offset, for example `2026-11-01T00:00:00Z` or `2026-11-01T00:00:00+05:30`. A value without an offset is rejected. A page past the end returns an empty `data` array with the real `itemCount`. # List device write activity Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/list-device-write-activity /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/devices/{deviceId}/activity Returns the values written to any point of a device, newest first. Use this to see who wrote what to a device and when. Each entry is one write to one of the device's points. Only writes made through KODE OS are listed: writes from the KODE OS app and from the KODE API, such as [Write to a point](/products/kode-api/api-reference/points/write-to-a-point). A value changed directly on the building automation system does not appear. Entries are sorted newest first. `asc`, `dsc`, and `q` are ignored. `from` and `to` are optional and inclusive. They need `Z` or a UTC offset, for example `2026-11-01T00:00:00.000Z`. Each entry's `time` uses the same format, so you can pass it back as `from` or `to`. There is no day limit on the range. `value` is the written value as text. The field it comes from depends on the connector, for example `value`, `level`, or `position`. A device without points returns `200` with an empty `data` array. # Remove device references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/remove-device-references /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/{deviceId}/references/batch-delete Removes the links between the device in the path and the listed devices. No device is deleted. The link is removed from both devices. The devices themselves, and their points, are not changed. A successful request returns `204` with an empty body. # Remove device space references Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/remove-device-space-references /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/{deviceId}/space-references/batch-delete Removes the links between the device in the path and the listed spaces. Neither the device nor the spaces are deleted. A successful request returns `204` with an empty body. # Update a device Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/update-a-device /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/devices/{deviceId} Changes the name, location, or metadata of one device. Fields you leave out keep their current value. Send only the fields you want to change. The device `id` comes from the path. > [!NOTE] > > The response is built from the saved device, so `curStatus` is `null`. Call [Get a device](/products/kode-api/api-reference/devices/get-a-device) for the current status. To change many devices in one request, use [Update devices in a batch](/products/kode-api/api-reference/devices/update-devices-in-a-batch). # Update devices in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/devices/update-devices-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/devices/batch-update Starts a job that updates up to 1,000 devices, each with its own fields. The update runs as a job. The request is checked for shape, a job is created, and the response returns that job. Poll [Get a job](/products/kode-api/api-reference/buildings/get-a-job) with the job `_id` until `status` is `COMPLETED`, `FAILED` or `CANCELED`. Each item has the device `id` and any of the fields of [Update a device](/products/kode-api/api-reference/devices/update-a-device). Fields you leave out keep their current value. Send each `id` once. > [!NOTE] > > The job checks that every device exists in the building. If any `id` is unknown or belongs to another building, the job ends with `FAILED` and no device is changed. After a `COMPLETED` job, read the devices to confirm the new values. # KODE API reference Source: https://docs.kodelabs.com/products/kode-api/api-reference/introduction Browse KODE API endpoints, switch code samples by language, and send test requests from the browser or Postman. Every endpoint page lists its parameters, request body, and response. The panel on the right has a language menu and a form that sends the request. ## Switch the code sample Open any endpoint, such as [List buildings](/products/kode-api/api-reference/buildings/list-buildings). Use the language menu above the sample to switch between cURL, JavaScript, Python, and PowerShell. The sample updates in place. ## Send the request from the browser **1. Get an access token** Follow the [quickstart](/products/kode-api/quickstart). Copy the `access_token` value. **2. Open the playground** Open [List buildings](/products/kode-api/api-reference/buildings/list-buildings?playground=open) and select **Try it**. **3. Authorize and send** Paste the token into `Authorization`, then select **Send**. The response appears under the sample. > [!WARNING] > > The playground sends real requests to your KODE environment. Write endpoints, such as point writes and work order updates, change live data. ## Run the collection in Postman Fork the collection if you want saved requests, environments, and tests in Postman. After you fork it, set `KODE_ACCESS_TOKEN` in a Postman environment and send any request. > [card] [Fork in Postman](https://elements.getpostman.com/view/fork?collection=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c\&documenterCollectionId=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c-2sAYkEqfGB\&referrer=https%3A%2F%2Fdocumenter.getpostman.com%2Fview%2F37847641%2F2sAYkEqfGB\&versionTag=latest\&source=documenter) > > Copy the KODE API collection into your Postman workspace, then run the requests there. You can also download the OpenAPI specification from the page menu and import that file into Postman. The published [KODE API collection](https://documenter.getpostman.com/view/37847641/2sAYkEqfGB) is the same collection the fork button copies. ## Find identifiers Most endpoints need an identifier from an earlier call: | Identifier | Where to get it | | - | - | | `buildingId` | [List buildings](/products/kode-api/api-reference/buildings/list-buildings) | | `datasourceId` | [List building data sources](/products/kode-api/api-reference/data-sources/list-building-data-sources) | | `deviceId` | [List building devices](/products/kode-api/api-reference/devices/list-building-devices) | | `pointId` | [List building points](/products/kode-api/api-reference/points/list-building-points) | | `workOrderId` | [List work orders](/products/kode-api/api-reference/work-orders/list-work-orders) | # Discover mass write point groups Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/discover-mass-write-point-groups /openapi/kode-api.yaml post /api/v1/mass-write/point-groups/query Finds the writable points that match a query and groups them. Each group has a `groupKey` and the fields a write to it can carry. Nothing is changed. A group holds writable points of the same kind, connector type, field, and unit or enum values. Use the groups to build the `writes` of a plan for [Validate or apply a mass write](/products/kode-api/api-reference/mass-write/validate-or-apply-a-mass-write). The body holds a `query`. Only `buildingIds` is required. Every other member is a filter. A point must match every filter you send. A filter you leave out, or send as an empty list, does not restrict the result. > [!WARNING] > > KODE API ignores a key it does not know, so a misspelled filter does not narrow the query. It widens it. Check `points` in the response before you write. > [!NOTE] > > Only writable points are grouped. A query can match at most 30,000 points. A building outside your account returns `400`, the same as a building that does not exist. `scope` is `PORTFOLIO` when matched points are in more than one building. `buildings` and `points` count across all pages. KODE API ignores `q`, `asc`, and `dsc`. Groups come in a fixed order. # Get a mass write operation Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/get-a-mass-write-operation /openapi/kode-api.yaml get /api/v1/mass-write/operations/{operationId} Returns the state, progress, and result of a mass write. Poll it until `done` is `true`. Use the last segment of `operation.name` from [Validate or apply a mass write](/products/kode-api/api-reference/mass-write/validate-or-apply-a-mass-write) as the `operationId`. This response is the operation itself. It is not wrapped in `operation`. > [!WARNING] > > Each read recounts the points. The read that finds every point done completes the operation. An operation you never read stays `RUNNING` and blocks the next mass write in its buildings. Poll every `metadata.pollAfterSeconds` until `done` is `true`. `metadata.state` is one of: * `QUEUED` and `RUNNING`: The write has not finished. `metadata.counts` shows how many points are `pending`, `succeeded`, and `failed`. * `SUCCEEDED`: Every point has an outcome. `response` holds `total`, `succeeded`, and `failed`. Some points can still have failed, so check `response.failed`. * `FAILED`: The write could not run to its end. `error` holds a `code` and a `message`. A point with no outcome two hours after the start is marked `FAILED` with the code `TIMEOUT`. Read the outcome of each point with [List mass write results](/products/kode-api/api-reference/mass-write/list-mass-write-results). # List mass write operations Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/list-mass-write-operations /openapi/kode-api.yaml get /api/v1/mass-write/operations Returns the mass write operations you started in your buildings, newest first, one page at a time. > [!NOTE] > > The list shows the stored state of each operation. It does not recount points, so an operation can show `RUNNING` after its points are done. [Get a mass write operation](/products/kode-api/api-reference/mass-write/get-a-mass-write-operation) refreshes it. A service account sees only the operations it started. An operation that covers several buildings appears under each of them. Use `state`, `buildingId`, `from`, and `to` to narrow the list. `from` and `to` filter on the creation date, in UTC. KODE API ignores `q`, `asc`, and `dsc`. # List mass write results Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/list-mass-write-results /openapi/kode-api.yaml get /api/v1/mass-write/operations/{operationId}/results Returns the points of an operation with the outcome of each, one page at a time. A point with `status` set to `FAILED` has an `errorCode` and a `message`. `INTERNAL_ERROR` means KODE could not deliver the write. It is safe to retry. `NOT_IN_PLAN` means the point joined the query after you validated the plan. KODE did not write it, and a retry does not send it. Use `status` and `buildingId` to narrow the list. KODE API ignores `q`, `asc`, and `dsc`. # Retry a mass write operation Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/retry-a-mass-write-operation /openapi/kode-api.yaml post /api/v1/mass-write/operations/{operationId}:retry Sends the failed points of an operation again. The operation runs again under the same id. The operation must be done and have failed points. An operation that was cut off with points that never got an outcome also qualifies. Those points are marked `FAILED` with the code `TIMEOUT` and sent again. Points that failed with `NOT_IN_PLAN` are not sent again. The operation goes back to `RUNNING`, and `metadata.retries` goes up by one. Poll it as you did after the apply. An operation you do not read stays `RUNNING` and blocks the next mass write in its buildings. > [!NOTE] > > The call returns `400` while the operation is not done, when no failed point can be sent again, or while another mass write is running in the same buildings. # Validate or apply a mass write Source: https://docs.kodelabs.com/products/kode-api/api-reference/mass-write/validate-or-apply-a-mass-write /openapi/kode-api.yaml post /api/v1/mass-write/points:apply Checks a mass write plan, or starts it as an operation that you poll until it finishes. Send `validateOnly` as `true` to check the plan without writing. > [!WARNING] > > A real apply writes to live points through their connectors. There is no undo call. To release an override, send `priority` with the release option from the group `fields`, for example `auto`. Always validate first, check `summary.points`, and start with a small query. A plan has a `query` and a list of `writes`. The `query` is the one you used in [Discover mass write point groups](/products/kode-api/api-reference/mass-write/discover-mass-write-point-groups). Each write lists `groupKeys` and `actions`. An action has an `id`, a field of the group, and a `value`. Every discovered group must be in exactly one write. Every action `id` must be a field of its groups. A value must fit the field `dataType`, and a `SELECT` field accepts only its `options`. **Validate first** With `validateOnly` set to `true`, the response holds `validationReport` and nothing is written. Read: * `valid`: `true` when the plan has no issue. * `summary`: How many points, groups, and writes the plan reaches, with counts of errors and warnings. * `writes[]`: The outcome of each write, in request order, with its own `issues`. * `issues`: Issues with the plan as a whole. * `unmatchedGroups`: Groups that no write covers. * `etag`: A fingerprint of the plan. It is present only when the plan is valid. Each issue has a `code`, a `pointer` to the part of your request, and a `message`. The codes are `NO_MATCHING_POINTS`, `UNKNOWN_GROUP`, `DUPLICATE_WRITE`, `WRITES_INCOMPLETE`, and `INVALID_ACTION`. A validation lists every issue. A real apply stops with `400` on the first kind of issue. **Start the write** Send the same body without `validateOnly`, with a `requestId` of your choice and the `etag` from the report. The response holds `operation`. Keep the last segment of `operation.name` as the `operationId`, then poll [Get a mass write operation](/products/kode-api/api-reference/mass-write/get-a-mass-write-operation). * The response is `200`, not `202`. * Sending the same `requestId` with the same body within 24 hours returns the operation it already started. Sending it with a different body returns `400`. * If the plan changed since you validated it, the `etag` no longer matches and the call returns `400`. Validate again to get a new `etag`. * A building can have only one mass write running. A second apply returns `400` with "Another point mass write is running" until the first operation is finished. An operation finishes when you read it and every point has an outcome. > [!NOTE] > > Your service account needs the permission to manage mass writes, including for a validation. Its role can also limit overrides. An override longer than the maximum duration returns `403`. An override longer than the reason threshold without a `reason` returns `400`. Names and reasons can have up to 255 characters, and `notes` up to 2,000. # Assign a meter to a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/assign-a-meter-to-a-space /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/meters/assignments Links a meter to a space. > [!NOTE] > > The meter and the space must be in the building. The body must hold the same `buildingId` as the path. Sending the same assignment again is not an error. > [!WARNING] > > With `exclusive` set to `true`, KODE removes the meter's existing space assignments before it adds the new one. Leave `exclusive` out unless you mean to replace them. > [!NOTE] > > The response is `204` with no body. To remove an assignment, use [Remove a meter assignment](/products/kode-api/api-reference/meters/remove-a-meter-assignment). # Delete a meter Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/delete-a-meter /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/meters/{meterId} Permanently deletes a meter. > [!WARNING] > > Deleting a meter is permanent and cannot be undone. > [!NOTE] > > The response is `204` with no body, also when no meter has this `meterId`. Read the meter afterwards to confirm that it is gone. A read returns `404`. # Get a meter Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/get-a-meter /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/meters/{meterId} Returns one meter. # Link child meters to a parent meter Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/link-child-meters-to-a-parent-meter /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/meters/references Makes one or more meters children of a parent meter. > [!NOTE] > > The parent and every child must be meters of the building. The body must hold the same `buildingId` as the path. Sending the same link again is not an error. The response is `204` with no body. > [!NOTE] > > To list the children of a meter, use the `parentMeterId` filter of [List meters](/products/kode-api/api-reference/meters/list-meters). To remove a link, use [Unlink a child meter](/products/kode-api/api-reference/meters/unlink-a-child-meter). # List meter readings Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/list-meter-readings /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/meters/{meterId}/readings Returns the manual readings of a meter, one page at a time. > [!NOTE] > > This operation uses `POST` and takes no body. Page through the readings with `page` and `limit`. # List meters Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/list-meters /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/meters Returns the meters of a building, one page at a time. Use the filters to narrow the list. A meter must match every filter you send. A filter value that matches nothing returns an empty page. `originType` and `canonicalType` must be supported values, in the exact letter case. An unsupported value returns `400`. # Remove a meter assignment Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/remove-a-meter-assignment /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/meters/{meterId}/assignments/{spaceId} Removes the link between a meter and a space. The meter and the space stay as they are. The response is `204` with no body, also when the meter has no assignment to this space. # Unlink a child meter Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/unlink-a-child-meter /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/meters/{parentMeterId}/references/{childMeterId} Removes the link between a parent meter and a child meter. Both meters stay as they are. The response is `204` with no body. # Update a meter Source: https://docs.kodelabs.com/products/kode-api/api-reference/meters/update-a-meter /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/meters/{meterId} Changes the details of a meter. > [!NOTE] > > Send the fields you want to change. Use `locatedIn` to put the meter in a space. To link a meter to a space it serves or measures, use [Assign a meter to a space](/products/kode-api/api-reference/meters/assign-a-meter-to-a-space). > [!NOTE] > > `status` must be `ACTIVE`, `OUT_OF_SERVICE`, or `DECOMMISSIONED`, in capitals. `installationDate` must be a date in `YYYY-MM-DD` format. # List canonical types Source: https://docs.kodelabs.com/products/kode-api/api-reference/ontology/list-canonical-types /openapi/kode-api.yaml get /api/v1/ontology/canonical-types Returns every canonical type that the KODE ontology defines. Use a canonical type to look up its fields and connections, and as the `canonicalType` of a templating plan. A canonical type is a standard kind of equipment, such as an air handler or a chiller. The list is the same for the whole organization and does not depend on a building. Send a canonical type exactly as listed. Values are case-sensitive, so `Chiller` does not match `chiller`. # List connection keys Source: https://docs.kodelabs.com/products/kode-api/api-reference/ontology/list-connection-keys /openapi/kode-api.yaml get /api/v1/ontology/connections Returns every connection key that the KODE ontology defines, sorted by key. Use it to find the key of a relationship between two devices. A connection key names a relationship between devices, such as a device that supplies air to another. The list is the same for the whole organization. To see which keys a given canonical type accepts, and in which direction, call [List connections for a canonical type](/products/kode-api/api-reference/ontology/list-connections-for-a-canonical-type). The order is fixed, so `asc` and `dsc` have no effect. # List connections for a canonical type Source: https://docs.kodelabs.com/products/kode-api/api-reference/ontology/list-connections-for-a-canonical-type /openapi/kode-api.yaml get /api/v1/ontology/canonical-types/{canonicalType}/connections Returns the connections that a device of the given canonical type can have, one row for each direction. Use a row to build the `relationship` of a device reference. Rows list `INPUT` connections first and `OUTPUT` connections after them. Each group is sorted by `key`. Each row has: * `key`: The connection key. * `type`: The direction on this canonical type, `INPUT` or `OUTPUT`. * `multi`: Whether the connection accepts more than one referenced device. * `canonicalTypes`: The canonical types the device on the other end may have. The `key`, `multi`, and `type` of a row are the `relationship` that you send when you add a device reference with `POST /api/v1/buildings/{buildingId}/devices/{deviceId}/references`. The order is fixed, so `asc` and `dsc` have no effect. A `canonicalType` that is not in [List canonical types](/products/kode-api/api-reference/ontology/list-canonical-types) returns `400`. # List fields for a canonical type Source: https://docs.kodelabs.com/products/kode-api/api-reference/ontology/list-fields-for-a-canonical-type /openapi/kode-api.yaml get /api/v1/ontology/canonical-types/{canonicalType}/fields Returns the ontology fields that are valid for a canonical type, with their unit, accepted point kinds, enum values, and defaults. Use them to match a point group to a field in a templating plan. Send the `field` of an item as the `field` of a mapping in a templating plan. Check these values before you send it: * `supportedKinds`: The point kinds the field can take, from `Number`, `Str`, and `Bool`. A field applies only to points of a supported kind. * `unit`: The field's unit `symbol` and `category`, in the unit system you request. A unit override in a plan must be in this category. * `requiredEnums` and `optionalEnums`: The enum values a `Bool` or `Str` point's read map can map to. A plan should map every required value. * `minBound` and `maxBound`: The limits the ontology enforces on the field's values. * `multi` and `multiLevel`: Whether a device can have more than one instance of the field, and how many at most. By default, units are in `IMPERIAL`. Send `unitSystem=METRIC` for metric units. The `q` parameter matches the field identifier. It is case-insensitive, and every word in `q` must appear in the identifier, in any order. > [!NOTE] > > A `canonicalType` that is not in [List canonical types](/products/kode-api/api-reference/ontology/list-canonical-types) returns `400`. # List units by category Source: https://docs.kodelabs.com/products/kode-api/api-reference/ontology/list-units-by-category /openapi/kode-api.yaml get /api/v1/ontology/units Returns every unit that the KODE ontology defines, grouped by unit category. Use it to pick a valid `unit` override for a templating plan. Each category, such as `temperature`, holds its units with a `symbol`, `name`, and the values the ontology uses to convert a value to the category's base unit (`multiplier` and `offset`). A unit override in a templating plan must belong to the same category as the field it changes. The `unit.category` of a field in [List fields for a canonical type](/products/kode-api/api-reference/ontology/list-fields-for-a-canonical-type) tells you which category that is. The list is the same for the whole organization. # Copy points to devices Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/copy-points-to-devices /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/points/copies Creates a copy of each listed point on each listed device. A copy is a point on another device that mirrors its source. Use copies to show the same point on a virtual device or on another equipment device without ingesting it twice. The request creates one copy for each pair of a point in `pointIds` and a device in `deviceIds`. The number of pairs, `pointIds` times `deviceIds`, cannot be more than 50. Repeated ids are merged. The request is refused with `400` before anything is written when: * A point or a device is not in this building. * A point is not an origin point. A copy cannot be copied. * The points sit on more than one device. * A device is the device or the base device of one of the points. * A device is not an origin or a virtual device. The response has one item per pair, in the order of the request. Each item has a `status`: * `CREATED`: The copy was created. * `COPY_EXISTS`: The pair already has a copy. Nothing was created, so you can repeat a request safely. * `LIMIT_REACHED`: The source point already has the maximum of 200 copies. Each `CREATED` item also carries the `_id` of the new copy, so you can read or delete it right away. The same `_id` appears in [List point copies](/products/kode-api/api-reference/points/list-point-copies). > [!NOTE] > > Copies are written device by device, not as one atomic change. If a later step fails, the response is `400`, copies that were already written stay, and the rest are not attempted. List the copies, then send the request again. Pairs that already exist return `COPY_EXISTS`. Deleting the source point deletes its copies. See [Delete a point](/products/kode-api/api-reference/points/delete-a-point). # Delete a point Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/delete-a-point /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/points/{pointId} Permanently deletes one point and every copy of it. > [!WARNING] > > A delete cannot be undone. It removes the point and every copy of the point on other devices. The point counts of the devices that held a removed copy are updated. The device that holds the point is not deleted. Deleting a copy removes only that copy. Its source point is not changed. A successful delete returns `204` with an empty body. Read the point with [Get a point](/products/kode-api/api-reference/points/get-a-point) to confirm it is gone. It answers `404`. # Delete points in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/delete-points-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/points/batch-delete Starts a job that permanently deletes up to 1,000 points and every copy of them. > [!WARNING] > > A delete cannot be undone. Each point is deleted with its copies, exactly as with [Delete a point](/products/kode-api/api-reference/points/delete-a-point). The delete runs as a job. Poll [Get a job](/products/kode-api/api-reference/buildings/get-a-job) with the job `_id` until `status` is `COMPLETED`, `FAILED` or `CANCELED`. > [!NOTE] > > Ids that are not points of this building are skipped, and the job still ends with `COMPLETED`. The job carries no per-point result. Read each point afterwards to confirm it is gone. # Get a point Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/get-a-point /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/points/{pointId} Returns one point in a building, with its current value and status. The response includes the live members `curVal`, `curStatus` and `curState`. For a point that is a copy, they show the values of its source. See [Copy points to devices](/products/kode-api/api-reference/points/copy-points-to-devices). # Get point priority array Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/get-point-priority-array /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/points/{pointId}/priority-array Returns the priority levels that currently hold a value on a point, read live from the data source. A writable point on a building automation system can hold a value at several priority levels. The lowest level number has the highest priority. To see which level is in effect, use [Get point write state](/products/kode-api/api-reference/points/get-point-write-state). KODE OS reads the levels from the data source on each request, so the response reflects the point now. A slow or unreachable data source makes the request slow or makes it fail. The response lists only the levels the data source reports, lowest level first. A level that is not listed holds no value. The level range depends on the connector, for example `0` to `15` or `1` to `16`. The response is `200` with an empty array when: * The point is not writable. * The point's connector cannot write to points, or has been deleted. * The connector does not keep a priority array for the point. * No level holds a value. This endpoint only reads. It does not write a value or release a level. # Get point write state Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/get-point-write-state /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/points/{pointId}/write-state Returns the priority level currently in effect on a point, read live from the data source. The level in effect is the lowest level number that holds a value. KODE OS reads it from the data source on each request, the same way as [Get point priority array](/products/kode-api/api-reference/points/get-point-priority-array). The response has one of three shapes: * **A level is in effect:** `supported` is `true`, and `activeLevel`, `value`, and `who` describe that level. * **No level holds a value:** `supported` and `relinquishDefault` are `true`, and the other fields are `null`. The point is at its relinquish default. The default value itself is not returned. * **Not supported:** `supported` is `false` when the point is not writable, or its connector cannot write to points or has been deleted. The other fields are `null` or `false`. A connector that does not keep a priority array for the point also returns `relinquishDefault: true`. This endpoint only reads. It does not write a value or release a level. # List building points Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/list-building-points /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/points Returns the points in a building. # List point copies Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/list-point-copies /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/points/copies Returns the point copies in a building, each with the point it copies and the device it sits on. Each copy is listed with its `_id`, its `name`, the `device` it sits on and its `source` point, each with its own `_id`. Filter by `sourcePointId` and `deviceId` to find the copy of one point on one device. An `asc` or `dsc` value that is not listed answers `400`. A filter that matches nothing returns an empty page, not an error. The `q` parameter is ignored. # List point write activity Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/list-point-write-activity /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/points/{pointId}/activity Returns the values written to a point, newest first. Use this to see who wrote what to a point and when. To see the writes to every point of a device, use [List device write activity](/products/kode-api/api-reference/devices/list-device-write-activity). Only writes made through KODE OS are listed: writes from the KODE OS app and from the KODE API, such as [Write to a point](/products/kode-api/api-reference/points/write-to-a-point). A value changed directly on the building automation system does not appear. Entries are sorted newest first. `asc`, `dsc`, and `q` are ignored. `from` and `to` are optional and inclusive. They need `Z` or a UTC offset, for example `2026-11-01T00:00:00.000Z`. Each entry's `time` uses the same format, so you can pass it back as `from` or `to`. There is no day limit on the range. `value` is the written value as text. The field it comes from depends on the connector, for example `value`, `level`, or `position`. # List point write fields Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/list-point-write-fields /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices/{deviceId}/points/{pointId}/fields Returns the fields accepted when writing to a point. Use the response to build the `actions` array for a point write. A field with `metadata.required` set to `CONDITIONAL` applies only when `metadata.filter` matches the other values you send. For example, `value` can be required only when `priority` is `override` or `set`. # Query points by identifier Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/query-points-by-identifier /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/points/query Returns the building points that match a list of point identifiers. > [!NOTE] > > Send up to 200 point identifiers per request. For more points, split them across requests and merge the results. # Update a point Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/update-a-point /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/points/{pointId} Changes the name, unit, precision, or write settings of one point. Fields you leave out keep their current value. Send only the fields you want to change. * `name` can be up to 255 characters. * `unit` needs both `_id` and `symbol`. It sets the point's unit only. The server stores the canonical symbol of the unit `_id`. * `writable: true` without `writeActionCapabilities` applies the default write capabilities. To update many points in one request, use [Update points in a batch](/products/kode-api/api-reference/points/update-points-in-a-batch). # Update points in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/update-points-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/points/batch-update Starts a job that updates up to 1,000 points, each with its own fields. The update runs as a job. The request is checked for shape, a job is created, and the response returns that job. Poll [Get a job](/products/kode-api/api-reference/buildings/get-a-job) with the job `_id` until `status` is `COMPLETED`, `FAILED` or `CANCELED`. Each item has the point `id` and any of the fields of [Update a point](/products/kode-api/api-reference/points/update-a-point). Fields you leave out keep their current value. Send each `id` once. > [!NOTE] > > The job checks that every point exists in the building. If any `id` is unknown or belongs to another building, the job ends with `FAILED` and no point is changed. After a `COMPLETED` job, read the points to confirm the new values. # Write to a point Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/write-to-a-point /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices/{deviceId}/points/{pointId}/write Sends a write to a single point. Build the `actions` array from the point write fields. > [!WARNING] > > Point writes can command live building equipment. Test with a non-critical point before you automate writes. Call [List point write fields](/products/kode-api/api-reference/points/list-point-write-fields) first to learn which fields the point accepts. # Write to points in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/points/write-to-points-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/points/batch-write Sends writes to multiple points on one data source. > [!WARNING] > > Point writes can command live building equipment. Check `failureCount` in the response before you treat the batch as complete. # Get a schedule Source: https://docs.kodelabs.com/products/kode-api/api-reference/schedules/get-a-schedule /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/schedules/{scheduleId} Returns one schedule of a building, with its current value, next change, and weekly or calendar definition. Use the `id` from [List schedules](/products/kode-api/api-reference/schedules/list-schedules). A schedule that does not exist, or that belongs to a different building, returns `404`. # List schedule points Source: https://docs.kodelabs.com/products/kode-api/api-reference/schedules/list-schedule-points /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/schedules/{scheduleId}/points Returns the points a schedule drives, and whether each link to the schedule is valid. Each item names a point, its device, and its area, with the schedule `slot` the point follows and the point's current value in `curVal`. `type` is `DIRECT` for a point linked to the schedule itself, or `INDIRECT` for a point that follows it through another link. A non-empty `invalidReason` means the link is broken and the schedule does not drive that point. A page past the last page returns an empty page, and `itemCount` is `0`. A schedule that does not exist, or that belongs to a different building, returns `404`. > [!NOTE] > > The `q` parameter is ignored on this endpoint. # List schedules Source: https://docs.kodelabs.com/products/kode-api/api-reference/schedules/list-schedules /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/schedules Returns the schedules of a building, newest first by default. Filter by type, origin, kind, or level. Each schedule includes its current value and its weekly or calendar definition. A schedule is a time-based plan that drives the value of points, such as a weekly occupancy plan or a holiday calendar. Schedules come from two origins: `DISCOVERY` for schedules read from the building system, and `KODEOS` for schedules created in KODE OS. This endpoint is read-only. You cannot create, edit, or delete schedules through the KODE API. Hidden schedules are left out unless you send `hidden=true`. With `hidden=true`, the response holds only the hidden schedules, not both groups. Weekly schedules (`type` is `WEEKLY`) return a `weekDays` object with the slots for each day, and, at the schedule level, `minVal`, `maxVal`, `unit` and `effectivePeriod` when they are set. Calendar schedules (`type` is `CALENDAR`) return `events` with the special days and none of the weekly members. `level` is the building level the schedule belongs to. To list the points a schedule drives, call [List schedule points](/products/kode-api/api-reference/schedules/list-schedule-points). > [!NOTE] > > The `q` and `fields` parameters are ignored on this endpoint. # Create a space assignment Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/create-a-space-assignment /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/space-assignments Assigns a tenant to one or more leasable spaces for a period. > [!WARNING] > > With `exclusive` set to `true`, KODE deletes every other assignment of the tenant in this building before it creates the new one. This cannot be undone. Leave `exclusive` out unless you mean to replace the tenant's assignments. > [!NOTE] > > Each space must be a space unit that is leasable. A level, a zone, or a space unit that is not leasable fails with `400` and the message "Invalid Spaces for Assignment". A tenant or space that is not in this building fails with `400`, and nothing is created. > [!NOTE] > > The response is `200`, not `201`. `isActive` is `true` when the assignment has started and has not ended. An assignment with no `startDate` is not active. The `type` is always `lease`. # Delete a space assignment Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/delete-a-space-assignment /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/space-assignments/{assignmentId} Permanently deletes a space assignment. > [!WARNING] > > Deleting an assignment is permanent and cannot be undone. The tenant and the spaces stay as they are. > [!NOTE] > > The response is `204` with no body. Read the assignment afterwards to confirm that it is gone. A read returns `404`. # Get a space assignment Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/get-a-space-assignment /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/space-assignments/{assignmentId} Returns one space assignment. # List assignments of a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/list-assignments-of-a-space /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/space-assignments/spaces/{spaceId}/assignments Returns the assignments that include one space, one page at a time. This works like [List space assignments](/products/kode-api/api-reference/space-assignments/list-space-assignments), limited to the space in the path. The other filters apply on top. A `spaceId` you send as a query parameter is ignored. A space that does not exist returns an empty page. # List assignments of a tenant Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/list-assignments-of-a-tenant /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/space-assignments/tenants/{tenantId}/assignments Returns the assignments of one tenant, one page at a time. This works like [List space assignments](/products/kode-api/api-reference/space-assignments/list-space-assignments), limited to the tenant in the path. The other filters apply on top. A tenant that does not exist returns an empty page. # List space assignments Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/list-space-assignments /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/space-assignments Returns the space assignments of a building, one page at a time. Use the filters to narrow the list. An assignment must match every filter you send. `spaceId` and `tenantId` match assignments that include the space or belong to the tenant. Repeat `spaceId` to match any of several spaces. A filter value that matches nothing returns an empty page. Send dates as `YYYY-MM-DD`. Each date filter includes the date you send. # Update a space assignment Source: https://docs.kodelabs.com/products/kode-api/api-reference/space-assignments/update-a-space-assignment /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/space-assignments/{assignmentId} Changes the dates and description of a space assignment. > [!WARNING] > > Send `startDate`, `endDate`, and `description` every time. A field you leave out is cleared. An empty `description` removes the description. > [!NOTE] > > You cannot change the tenant or the spaces of an assignment. KODE ignores them if you send them. To change them, delete the assignment and create a new one. `isActive` is worked out again after each update. # Create a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/create-a-space /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/spaces Creates one level or space unit in a building. > [!NOTE] > > Send `category` as `Level` to create a top-level space, or as `SpaceUnit` with a `parentSpaceId` to create a space inside a level. A space unit without a `parentSpaceId` fails with `400`. > [!NOTE] > > The body must hold the same `buildingId` as the path. The response is `200`, not `201`, and holds the new space. To create several levels or space units in one call, use [Create levels](/products/kode-api/api-reference/spaces/create-levels) or [Create space units](/products/kode-api/api-reference/spaces/create-space-units). # Create levels Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/create-levels /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/spaces/levels Creates one or more levels in a building in one call. > [!NOTE] > > Send the building as the `buildingId` query parameter too. Use the same building as in the path. > [!NOTE] > > Each level needs a `name`. Names must be unique in the request and in the building. The response is `200`. `insertedIds` maps the position of each level in your request, starting at `0`, to the id of the new level. # Create space units Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/create-space-units /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/spaces/space-units Creates one or more space units in a building in one call. > [!NOTE] > > Send the building as the `buildingId` query parameter too. Use the same building as in the path. > [!NOTE] > > Each space unit needs a `name` and a `partOfId`, the level or space it belongs to. The `partOfId` must be in this building. Names must be unique in the request. The response is `200`. `insertedIds` maps the position of each space unit in your request, starting at `0`, to the id of the new space unit. # Get a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/get-a-space /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/spaces/{spaceId} Returns one space of a building. # List meters of a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/list-meters-of-a-space /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/spaces/{spaceId}/meters Returns the meters of a space, one page at a time. Use the filters to narrow the list. A filter value that matches nothing returns an empty page. `originType` must be one of the listed values, in the exact letter case. `q` searches the meter name. An empty `q` returns every meter. # List spaces Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/list-spaces /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/spaces Returns the levels and space units of a building, one page at a time. Use the filters to narrow the list. A space must match every filter you send. A filter value that matches nothing returns an empty page, not an error. `category` must be one of the listed values, in the exact letter case. `q` searches the space name. The match is not case-sensitive and can start anywhere in the name. An empty `q` returns every space. # Update a space Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/update-a-space /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/spaces/{spaceId} Changes the details of a space. > [!WARNING] > > Send every value you want the space to keep, not only the ones that change. Read the space with [Get a space](/products/kode-api/api-reference/spaces/get-a-space) and send it back with your changes. > [!NOTE] > > The body must hold the same `buildingId` as the path. Renaming a level to the name of another level in the building fails with `400`. # Update spaces in a batch Source: https://docs.kodelabs.com/products/kode-api/api-reference/spaces/update-spaces-in-a-batch /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/spaces/batchUpdate Changes the details of several spaces in one call. > [!NOTE] > > Send the building as the `buildingId` query parameter too. Use the same building as in the path. > [!NOTE] > > Each item needs the `id` of a space in this building. The response is `204` with no body. Send the fields you want to change, then read the spaces to confirm. # Apply a templating plan Source: https://docs.kodelabs.com/products/kode-api/api-reference/templating/apply-a-templating-plan /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/templating:apply Applies ontology fields and enum maps to the points of the devices you select. The call validates the plan and starts an operation that you poll until it finishes. Send `validateOnly` as `true` to check the plan without changing anything. > [!WARNING] > > Applying a plan rewrites live data on every matched point: its name, display name, unit, ontology fields, and enum maps. It also sets the canonical type on the devices. There is no undo call. [Clear a templating plan](/products/kode-api/api-reference/templating/clear-a-templating-plan) removes the ontology fields and restores the connector name and unit, but it does not restore other values. Always validate first, check `summary.matchedPoints`, and test on a non-critical device. A plan has a `canonicalType`, the `deviceIds` it covers (1 to 2,000), and up to 1,000 `mappings`. Each mapping has: * `match`: The points to change. Send exactly one of `groupKey`, a tuple (`name`, `kind`, `unitSymbol`, `writable`, `pointEnum`), or `pointIds`. * `field`: The catalog field to apply, from [List fields for a canonical type](/products/kode-api/api-reference/ontology/list-fields-for-a-canonical-type). * `overrides`: Optional changes to the field's defaults, such as `displayName`, `unit`, `precision`, `covTolerance`, `defaultInGraph`, `prefix`, `suffix`, and `dataInterval`. * `enumMapping`: Optional enum maps for `Bool` and `Str` points. `action` is `SET` to replace the maps, `UNSET` to remove them, or `KEEP` to leave them as they are. `KEEP` is the default. A point-level mapping (`pointIds`) takes precedence over a group mapping that covers the same point. A plan can cover at most 5,000 distinct point ids. **Validate first** With `validateOnly` set to `true`, the response holds `validationReport` and nothing is written. Read: * `valid`: `true` when no issue has `ERROR` severity. * `summary`: How many points and devices the apply would reach, with counts of errors and warnings. * `mappings[]`: The outcome of each mapping, in request order, with its own `issues`. * `issues`: Findings about the whole plan, such as devices that are already templated under another canonical type. * `unmappedGroups`: Groups in your device selection that no mapping covers. * `etag`: A fingerprint of the resolved plan. Each issue has a `code`, a `pointer` to the part of your request it concerns, and a `message`. `ERROR` issues stop the apply. Warnings, such as `NO_MATCH` or `ENUM_MAPPING_RECOMMENDED`, do not. **Start the run** Send the same body with `validateOnly` removed (or `false`), a `requestId` of your choice, and the `etag` from the report. The response holds `operation`. Keep the last segment of `operation.name` as the `operationId` and poll [Get a templating operation](/products/kode-api/api-reference/templating/get-a-templating-operation). * Only `validateOnly: true` makes a dry run. If you leave `validateOnly` out, the call starts a real run. * The `requestId` is unique per building. Sending the same `requestId` with the same body again returns the operation it already started. Sending it with a different body returns `400`. * If the plan changed since you validated it, the `etag` no longer matches and the call returns `400`. Validate again to get a new `etag`. Leave `etag` out to skip the check. * The API does not stop two runs from touching the same points. The last write wins. > [!NOTE] > > Your service account needs the permission to manage device and point templating, including for a dry run. # Clear a templating plan Source: https://docs.kodelabs.com/products/kode-api/api-reference/templating/clear-a-templating-plan /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/templating:clear Removes ontology fields and enum maps from points. It takes the same request as apply. Without mappings, it clears every templated point of the canonical type on the devices you select. > [!WARNING] > > A clear changes live data on every matched point and cannot be undone. It resets each point's name and display name to the connector name and its unit to the connector unit, and it removes the ontology fields, enum maps, and graphing defaults. A request without `mappings` clears the whole device selection for the canonical type. Validate first and check `summary.matchedPoints`. Send the same body as [Apply a templating plan](/products/kode-api/api-reference/templating/apply-a-templating-plan): `canonicalType`, `deviceIds`, `requestId`, and optionally `etag` and `validateOnly`. The same rules for validation, `etag`, and `requestId` replay apply. A clear mapping needs only `match`. Leave out `field`, `overrides`, and `enumMapping`. * **With mappings**, only the points the mappings match are cleared. If no mapping matches a point, nothing is cleared. * **Without mappings**, or with an empty list, every point templated under `canonicalType` on the selected devices is cleared. A dry run with no mappings reports in `summary.matchedPoints` and `summary.devicesAffected` how many points and devices a real clear would reach. When a clear leaves a device with no templated point, the device and its points also lose the `canonicalType`, so you can template the device again under another type. A point that is cleared while its device still has other templated points keeps the canonical type. Clear does not remove `dataInterval` or the write capabilities that apply set on points. Virtual points are not touched. Points on platform-managed connectors are skipped. # Discover templating point groups Source: https://docs.kodelabs.com/products/kode-api/api-reference/templating/discover-templating-point-groups /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/templating/point-groups/query Groups the points of the devices you select, and reports for each group whether it is already templated and whether its enum values are mapped. Use the groups to build a templating plan. Nothing is changed. A point group holds the points of the selected devices that share the same connector name, kind, writable flag, and unit (for `Number` points) or enum values (for `Bool` and `Str` points). Points in one group can take the same ontology field, so you map one field to the whole group. Only real points are grouped. Virtual and metadata points are left out. Each group has a `groupKey` that the server derives from those values. Send it in the `match` of a mapping when you [apply a plan](/products/kode-api/api-reference/templating/apply-a-templating-plan). The body selects the devices with `deviceIds` (1 to 2,000) and can filter the groups: * `templateStatuses`: `NOT_TEMPLATED` or `TEMPLATED`. * `kinds`: `Number`, `Bool`, or `Str`. * `enumStatuses`: `N_A`, `UNMAPPED`, `PARTIALLY_MAPPED`, or `MAPPED`. `N_A` means the group has no enum to map, as with `Number` points. Within a filter, a group matches any listed value. Across filters, a group must match every filter. The `q` parameter keeps only groups whose connector name contains the text. `currentFields` lists the fields already applied to the group's points, with a point count for each. Remove it from `fields` if you do not need it, because it costs extra work on the server. > [!NOTE] > > The body is the same selection you use for [List points in a point group](/products/kode-api/api-reference/templating/list-points-in-a-point-group) and for [Apply a templating plan](/products/kode-api/api-reference/templating/apply-a-templating-plan). Your service account needs the permission to view device and point templating. Applying and clearing need the permission to manage it. # Get a templating operation Source: https://docs.kodelabs.com/products/kode-api/api-reference/templating/get-a-templating-operation /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/templating/operations/{operationId} Returns the state, progress, and result of an apply or clear run. Poll it until `done` is `true`. Use the last segment of `operation.name` from [Apply a templating plan](/products/kode-api/api-reference/templating/apply-a-templating-plan) or [Clear a templating plan](/products/kode-api/api-reference/templating/clear-a-templating-plan) as the `operationId`. This response is the operation itself. It is not wrapped in `operation`. `metadata.state` is one of: * `QUEUED` and `RUNNING`: The run has not finished. * `SUCCEEDED`: The run finished. `response` holds `matchedPoints` and `devicesAffected`. * `FAILED`: The run stopped with an error. `error` holds the engine's `code` and `message`. * `STALLED`: The run is `RUNNING` but has not reported progress for a while. It is not finished, so `done` stays `false`. KODE API works this state out when you read the operation. `metadata.progress` is a percentage that updates after each batch. Do not use it to detect completion. Use `done`. When the run is `SUCCEEDED`, graphics, device references, and device linking update in the background afterwards. They can lag behind the point data for a short time. # List points in a point group Source: https://docs.kodelabs.com/products/kode-api/api-reference/templating/list-points-in-a-point-group /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/templating/point-groups/{groupKey}/points Returns the points that belong to one point group, each with its current field and enum-mapping status. Use it to review a group before you apply a plan, or to pick single points. Send the same `deviceIds` you used to discover the group, and the `groupKey` from the discovery response. Repeat the `deviceIds` parameter once for each device. Because the ids go in the URL, a very long list can exceed the request-line limit. Discover and drill into the devices in smaller batches if you reach it. Each point shows the `field`, `displayName`, `canonicalType`, `prefix`, and `suffix` it carries now, if it is templated. `enumStatus` shows whether its enum values are mapped. Use a point's `id` in the `pointIds` of a mapping to template that point apart from its group. A `groupKey` that is malformed, or that matches no group of the selected devices, returns `400`. Virtual points are never listed. # Create a tenant Source: https://docs.kodelabs.com/products/kode-api/api-reference/tenants/create-a-tenant /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/tenants Creates a tenant in a building. > [!NOTE] > > Only `name` is required. The response is `200`, not `201`, and holds the new tenant. The tenant belongs to the building in the path. > [!NOTE] > > A tenant is what you assign to spaces with [Create a space assignment](/products/kode-api/api-reference/space-assignments/create-a-space-assignment). The `logo` can be set only now. It cannot be changed later. # Delete a tenant Source: https://docs.kodelabs.com/products/kode-api/api-reference/tenants/delete-a-tenant /openapi/kode-api.yaml delete /api/v1/buildings/{buildingId}/tenants/{tenantId} Permanently deletes a tenant. > [!WARNING] > > Deleting a tenant is permanent and cannot be undone. Check the tenant's space assignments first. > [!NOTE] > > The response is `204` with no body, also when no tenant has this `tenantId`. Read the tenant afterwards to confirm that it is gone. A read returns `404`. # Get a tenant Source: https://docs.kodelabs.com/products/kode-api/api-reference/tenants/get-a-tenant /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/tenants/{tenantId} Returns one tenant. # List tenants Source: https://docs.kodelabs.com/products/kode-api/api-reference/tenants/list-tenants /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/tenants Returns the tenants of a building, one page at a time. Use `status` to narrow the list. The value is case-sensitive. Repeat the parameter to match any of several statuses. A value that matches nothing returns an empty page. # Update a tenant Source: https://docs.kodelabs.com/products/kode-api/api-reference/tenants/update-a-tenant /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/tenants/{tenantId} Changes the details of a tenant. > [!WARNING] > > Send every value you want the tenant to keep, including `name`. A value you leave out can be cleared, and `status` can go back to `active`. Read the tenant with [Get a tenant](/products/kode-api/api-reference/tenants/get-a-tenant) and send it back with your changes. > [!NOTE] > > The `logo` cannot be changed after the tenant is created. # List latest point values Source: https://docs.kodelabs.com/products/kode-api/api-reference/timeseries/list-latest-point-values /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/timeseries/last Returns the most recent value for one or more points. Only points that belong to the building are returned. # List point timeseries Source: https://docs.kodelabs.com/products/kode-api/api-reference/timeseries/list-point-timeseries /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/timeseries Returns timeseries values for a building, filtered by time range, device, or point. > [!NOTE] > > The range between `from` and `to` has a maximum length in days. A longer range returns `400`, and the error message states the limit. Split longer ranges into multiple requests. # Send historical values for a point Source: https://docs.kodelabs.com/products/kode-api/api-reference/timeseries/send-historical-values-for-a-point /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices/{deviceId}/points/{pointId}/timeseries Records historical values for a single point. # Send timeseries for a data source Source: https://docs.kodelabs.com/products/kode-api/api-reference/timeseries/send-timeseries-for-a-data-source /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/timeseries Sends point values for one or more devices on a KODE API data source (`API_KODE`). # Send timeseries for a device Source: https://docs.kodelabs.com/products/kode-api/api-reference/timeseries/send-timeseries-for-a-device /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/integrations/datasources/{datasourceId}/devices/{deviceId}/timeseries Sends point values for a single device. Use this endpoint to keep payloads small when a device has many points. # Assign an app to a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/assign-an-app-to-a-user /openapi/kode-api.yaml post /api/v1/users/{userId}/apps/{appId} Gives a user access to an app with a role. The assignment finishes in the background. > [!NOTE] > > Only `bms` can be assigned through the API. The value is case-sensitive. Any other `appId` fails with `400`, and so does a role that does not exist for your organization's `bms` app. > [!NOTE] > > The response is `202` with no body, which means KODE accepted the assignment. It is not finished yet. Call [Get a user](/products/kode-api/api-reference/users/get-a-user) and read `assignedInApps[].assignmentStatus` until it is `SUCCEEDED` or `FAILED`. The values are `INITIALIZING`, `PROCESSING`, `SUCCEEDED`, `FAILED`, and `PENDING`. `PENDING` applies to a guest who has not accepted the invitation. The assignment does not run until the guest accepts. > [!NOTE] > > `buildingIds` limits the user's access to those buildings. The IDs must be buildings of your organization. The API does not return them, so `assignedInApps` shows no building list. > [!WARNING] > > Assigning an app to an active user can send that user an email. Check that the user is the right one before you send the request. # Create a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/create-a-user /openapi/kode-api.yaml post /api/v1/users Creates an internal user in your organization with an organization role. The user has no app access until you assign an app. > [!WARNING] > > If you set `active` to `true`, KODE sends an email to the address you provide, with a link to set a password. Check the email address before you send the request. If you set `active` to `false`, the user is created disabled and no email is sent. > > To activate the user later, use [Update the status of a user](/products/kode-api/api-reference/users/update-the-status-of-a-user). > [!NOTE] > > The new user is always an `INTERNAL` user and has no app access. To give access, call [Assign an app to a user](/products/kode-api/api-reference/users/assign-an-app-to-a-user) with the `_id` from the response. > [!NOTE] > > The email address must be unique in your organization, and the API stores it in lower case. A second request with the same address, in any letter case, fails with `400`. Names can have up to 40 characters, and `position` up to 200. `phone` must be an international number that starts with `+`. Values that contain HTML tags are stored HTML-escaped. # Delete a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/delete-a-user /openapi/kode-api.yaml delete /api/v1/users/{userId} Permanently deletes a user from your organization. > [!WARNING] > > Deleting a user is permanent and cannot be undone. The user is removed from your organization, and the user's app access goes with it. KODE does not unassign the user's apps first, so the delete succeeds even while an app assignment is still being set up. > [!NOTE] > > If you create a user again with the same email address, the new user gets the same `_id` as the deleted one. > [!NOTE] > > To remove a person's access without deleting the user, use [Update the status of a user](/products/kode-api/api-reference/users/update-the-status-of-a-user) to deactivate the user, or [Remove app access from a user](/products/kode-api/api-reference/users/remove-app-access-from-a-user). # Get a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/get-a-user /openapi/kode-api.yaml get /api/v1/users/{userId} Returns one user of your organization, including the apps the user can access and the state of each app assignment. > [!NOTE] > > After you assign an app, read the user and check `assignedInApps[].assignmentStatus` to see whether the assignment is finished. # Invite a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/invite-a-user /openapi/kode-api.yaml post /api/v1/users/invite Adds a user from another organization to your organization as a guest, with an organization role. > [!WARNING] > > KODE sends an invitation email only when the invitee already has an account in the organization you set in `trustedOrganizationId`. If not, the guest is created and no email is sent. Check the email address before you send the request. > [!NOTE] > > The new user is a `GUEST` with `active` set to `true` and `invitationStatus` set to `PENDING`. You send no name. The user is `ACCEPTED` once the invitation is accepted. An app you assign to a pending guest stays `PENDING` until then. > [!NOTE] > > `trustedOrganizationId` is the id of the guest's home organization. The email address must not belong to a user who already exists in your organization. # List users Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/list-users /openapi/kode-api.yaml get /api/v1/users Returns the users of your organization, one page at a time, with the apps each user can access. > [!NOTE] > > Each user in `data` includes `assignedInApps`, the apps the user can access and the role in each. Use the filters to find users by role, app, status, or member type. A user must match every filter you send. > [!NOTE] > > Users are ordered by `_id`, highest first, unless you send `asc` or `dsc`. # Remove app access from a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/remove-app-access-from-a-user /openapi/kode-api.yaml delete /api/v1/users/{userId}/apps/{appId} Removes a user's access to an app. The user stays in your organization. > [!WARNING] > > The user loses access to the app. Assign the app again to restore it. > [!NOTE] > > The user must have the app. If not, the request fails with `400` and the message "App not found", so a second call for the same user and app returns `400`. Wait until `assignmentStatus` is `SUCCEEDED` or `FAILED` before you remove access that is still being set up. You can remove an assignment that is `PENDING`. # Update a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/update-a-user /openapi/kode-api.yaml put /api/v1/users/{userId} Changes the name, organization role, phone number, or position of a user. > [!NOTE] > > You cannot change `email` with this operation. To change `active`, use [Update the status of a user](/products/kode-api/api-reference/users/update-the-status-of-a-user). To change app access, use [Assign an app to a user](/products/kode-api/api-reference/users/assign-an-app-to-a-user), [Update the KODE OS role of a user](/products/kode-api/api-reference/users/update-the-kode-os-role-of-a-user), and [Remove app access from a user](/products/kode-api/api-reference/users/remove-app-access-from-a-user). > [!NOTE] > > Send the fields you want to change. A field you leave out keeps its value. A blank name or role is ignored. An empty `phone` or `position` clears the value. Names can have up to 40 characters, and `position` up to 200. > [!WARNING] > > This operation returns `403` if you set `role` to `CLIENT_ADMIN`. The `role` field here is the organization role. The role in an app changes with [Update the KODE OS role of a user](/products/kode-api/api-reference/users/update-the-kode-os-role-of-a-user). # Update the KODE OS role of a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/update-the-kode-os-role-of-a-user /openapi/kode-api.yaml put /api/v1/users/{userId}/apps/{appId} Changes the role a user has in an app they already have access to. > [!NOTE] > > This changes the role in the app only. The user's organization role stays the same. To change the organization role, use [Update a user](/products/kode-api/api-reference/users/update-a-user). > [!NOTE] > > The user must already have the app. If not, the request fails with `400` and the message "App not found". Wait until `assignmentStatus` is `SUCCEEDED` or `FAILED` before you change the role. A change while the assignment is still being set up is rejected. # Update the status of a user Source: https://docs.kodelabs.com/products/kode-api/api-reference/users/update-the-status-of-a-user /openapi/kode-api.yaml put /api/v1/users/{userId}/status Activates or deactivates a user. Send `active` as `true` or `false`. > [!WARNING] > > The first time KODE activates a user, it sends an account email to the user's address, with a link to set a password. Check that the user is the right one before you send the request. > [!NOTE] > > Send the status the user does not have yet. A request for the status the user already has fails with `400` and the message "Invalid status update". Read the user with [Get a user](/products/kode-api/api-reference/users/get-a-user) to check `active` first. > [!NOTE] > > The response is the updated user. A deactivated user stays in your organization. To delete the user, use [Delete a user](/products/kode-api/api-reference/users/delete-a-user). # Attach points to a virtual device Source: https://docs.kodelabs.com/products/kode-api/api-reference/virtual-devices/attach-points-to-a-virtual-device /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/virtual-devices/{virtualDeviceId}/points Moves points from their pseudo device onto a virtual device. > [!WARNING] > > Attaching moves a point. It keeps its `id` and its trend data, but its modeling is reset, including canonical type, measurement, precision and unit. Attach first, then apply modeling. Only origin points on pseudo devices can be attached. The point's current device is read from the point. A copy, a point on a real device, and a point on a different virtual device are refused with `400`. To show a point of a real device on a virtual device, use [Copy points to devices](/products/kode-api/api-reference/points/copy-points-to-devices). The request is checked as a whole before anything moves. The points are then moved one source device at a time. If one device fails, the devices before it stay attached and the rest are not attempted. Repeat the request: points already on the virtual device are skipped and listed in `skipped`. The response has `attached`, the ids of the points that were moved, and `skipped`, a list of `pointId` and `reason` for the points that were already on the device. The order of ids in `attached` is not defined. # Create a virtual device Source: https://docs.kodelabs.com/products/kode-api/api-reference/virtual-devices/create-a-virtual-device /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/virtual-devices Creates an empty virtual device in a building. A virtual device groups points that come from other devices. Only `name` is required. The server generates the `id`, sets the device as virtual, and starts it with no points. A body `_id`, `building`, `originType` or `pointIds` is ignored. Sending the same `name` again creates a second device. The response has these members: `id`, `name`, `type` (`id` and `name`), `locatedIn` (`id` and `name`), `area` (`id` and `name`), `location`, `pointsCount`, `createdAt` and `updatedAt`. `type`, `locatedIn`, `area` and `location` are empty when you did not send them. `area` is the level of the space in `locatedInSpaceId`. * `name` is trimmed and can be up to 255 characters. * `typeId` is the device type. Take it from `type._id` of an existing device. Up to 128 characters. * `locatedInSpaceId` is the `id` of a space in this building. Up to 128 characters. Add points to the device with [Copy points to devices](/products/kode-api/api-reference/points/copy-points-to-devices) or [Attach points to a virtual device](/products/kode-api/api-reference/virtual-devices/attach-points-to-a-virtual-device). # Detach points from a virtual device Source: https://docs.kodelabs.com/products/kode-api/api-reference/virtual-devices/detach-points-from-a-virtual-device /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/virtual-devices/{virtualDeviceId}/points/batch-delete Takes points off a virtual device. Origin points return to their base device. Copies are deleted. > [!WARNING] > > A copy cannot go back to a base device, so detaching a copy deletes it. Copies are listed in `deletedCopies`. This cannot be undone. Every point in `pointIds` must be on this virtual device. The request is all or nothing. If any id is not on the device, nothing changes. The response has `detached`, the ids of origin points returned to their base device, and `deletedCopies`, the ids of copies that were deleted. The order of ids in both lists is not defined. Repeating a request that already succeeded returns `400`, because the points are no longer on the device. Schedule references move back to the base device after the detach, so they can lag behind the response. # Create a work order Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/create-a-work-order /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/assetops/work-orders Creates a corrective maintenance or service request work order. Get valid `category`, `issueType`, `vendor`, `team`, `priority`, and `assignees` identifiers from the lookup endpoints first. See [Manage work orders](/products/kode-api/guides/manage-work-orders). # Get a work order Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/get-a-work-order /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/{workOrderId} Returns a single work order. # List assignees Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-assignees /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/potential-assignees Returns users you can assign to a work order. # List building comments Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-building-comments /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/comments Returns work order comments across a building. Use it to sync or audit comments. # List categories and issue types Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-categories-and-issue-types /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/potential-category-issue-types Returns valid category and issue type combinations for work orders in a building. # List priorities Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-priorities /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/potential-priorities Returns the priorities available for work orders in a building. # List teams Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-teams /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/potential-teams Returns teams you can assign to a work order. # List vendors Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-vendors /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/potential-vendors Returns vendors you can assign to a work order. # List work order comments Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-work-order-comments /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders/{workOrderId}/comments Returns the comments on a work order. # List work orders Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/list-work-orders /openapi/kode-api.yaml get /api/v1/buildings/{buildingId}/assetops/work-orders Returns the work orders for a building. # Update a work order Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/update-a-work-order /openapi/kode-api.yaml put /api/v1/buildings/{buildingId}/assetops/work-orders/{workOrderId} Replaces the editable details of a work order. You cannot change `workType` or `linkedSource`. > [!WARNING] > > This is a full update. Omitted optional fields such as `description`, `vendor`, `team`, and `assignees` can be cleared. Omitting `priority` keeps the current priority. Get the work order first, change only the fields you need, then send the complete body. # Upload attachments Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/upload-attachments /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/assetops/work-orders/{workOrderId}/attachments Uploads up to 10 files to a work order as multipart form data. # Upload base64 attachments Source: https://docs.kodelabs.com/products/kode-api/api-reference/work-orders/upload-base64-attachments /openapi/kode-api.yaml post /api/v1/buildings/{buildingId}/assetops/work-orders/{workOrderId}/attachments/base64 Uploads up to 10 base64-encoded files to a work order. Use it when your integration already holds file content as base64. # Authenticate with the KODE API Source: https://docs.kodelabs.com/products/kode-api/authentication Use OAuth 2.0 client credentials and signed JWT assertions to authenticate KODE API requests. The KODE API uses OAuth 2.0 client credentials with a signed JSON Web Token (JWT) client assertion. Your service proves its identity with a private key instead of sending a reusable secret. ## How authentication works ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} %%{init: {"theme": "neutral"}}%% sequenceDiagram participant Service as Your service participant Auth as KODE authorization server participant API as KODE API Service->>Service: Sign client assertion with private key Service->>Auth: POST /oauth2/v1/token Auth-->>Service: Bearer access token Service->>API: Request with Authorization header API-->>Service: JSON response ``` 1. Sign a short-lived JWT client assertion with the private key registered for your client ID. 2. Exchange the assertion for an access token at the token endpoint. 3. Send the access token in the `Authorization` header of each API request. 4. Request a new token before the current one expires. > [!WARNING] > > Keep private keys in an approved secrets manager. Never place private keys or access tokens in browser code, mobile apps, logs, or source control. ## Get your credentials You receive a client ID with your KODE project delivery. Contact your KODE project team if you have a client ID but cannot locate the matching private key. > [!NOTE] > > The exact client assertion claims and credential retrieval steps are being finalized. Until then, follow the instructions supplied with your project delivery. ## Create a client assertion Sign the assertion with your private key, following the JWT bearer profile in [RFC 7523](https://datatracker.ietf.org/doc/html/rfc7523). Create a new, short-lived assertion for each token request. To confirm supported signing algorithms, call [Get authorization server metadata](/products/kode-api/api-reference/authentication/get-authorization-server-metadata). This endpoint does not require authentication. ## Request an access token Send the assertion to [Create an access token](/products/kode-api/api-reference/authentication/create-an-access-token) as form data: ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --fail-with-body \ --request POST "https://api.kodelabs.com/oauth2/v1/token" \ --data-urlencode "grant_type=client_credentials" \ --data-urlencode "scope=bms" \ --data-urlencode "client_assertion_type=urn:ietf:params:oauth:client-assertion-type:jwt-bearer" \ --data-urlencode "client_assertion=${KODE_CLIENT_ASSERTION}" ``` The response includes `access_token` and `expires_in`. Use the returned lifetime instead of assuming a fixed value. ## Use the token Send the token as a Bearer token: ```http theme={"theme":{"light":"github-light","dark":"github-dark"}} Authorization: Bearer ``` To try endpoints in the browser, paste the token into the `Authorization` field of any [API reference](/products/kode-api/api-reference/introduction) page. ## Renew and revoke tokens Cache the token and reuse it until it nears expiration, then request a new one. When multiple service instances share one client ID, coordinate renewals so each instance does not request its own token. If a token is exposed, call [Revoke an access token](/products/kode-api/api-reference/authentication/revoke-an-access-token) with a new client assertion. ## Resolve authentication errors | Response | Cause | Fix | | - | - | - | | `401` from the token endpoint | The assertion is expired, malformed, or signed with the wrong key. | Check the assertion lifetime, audience, and signing algorithm. | | `401` from the API | The access token is missing, invalid, or expired. | Request a new access token. | | `403` from the API | The service account lacks permission for the building or operation. | Ask your KODE project team to update the service account permissions. | # KODE API fundamentals Source: https://docs.kodelabs.com/products/kode-api/fundamentals Build reliable KODE API integrations with consistent requests, pagination, rate-limit handling, and error recovery. Use these conventions across KODE API integrations. Individual endpoint pages document limits or behavior that differ for a specific resource. ## Base URL and version Version one resources use: ```text theme={"theme":{"light":"github-light","dark":"github-dark"}} https://api.kodelabs.com/kodeos/api/v1 ``` Build paths from this base URL. Do not remove the `/api/v1` segment. ## Request format Send and receive JSON unless an endpoint documents another media type. ```http theme={"theme":{"light":"github-light","dark":"github-dark"}} Accept: application/json Content-Type: application/json Authorization: Bearer ``` You do not need `Content-Type` for requests without a body. Attachment endpoints can require `multipart/form-data` or base64-encoded JSON. ## Pagination List endpoints commonly accept `page` and `limit`. **page** `integer` (default: 1) Page number to retrieve. The first page is `1`. **limit** `integer` (default: 50) Maximum number of items to return. Some endpoints support up to `200`. Paginated responses commonly include: **data** `array` *required* Resources returned for the current page. **itemCount** `integer` *required* Total number of matching resources. **limit** `integer` *required* Maximum number of resources returned per page. **page** `integer` *required* Current page number. **pageCount** `integer` *required* Total number of available pages. Stop requesting pages when `page` equals `pageCount`. Do not infer completion from a short page when the response provides pagination metadata. ## Rate limits KODE applies concurrent rolling limits per environment, such as `acme.kodelabs.com`. | Window | Limit | | - | -: | | One second | 5 requests | | 60 seconds | 100 requests | | 3,600 seconds | 500 requests | Every request that reaches the gateway counts, including requests that return `4xx` or `5xx`. Exceeding any window returns `429 Too Many Requests`. > [!TIP] > > Queue requests per environment and add random jitter to retries. This prevents multiple workers from retrying at the same time. ## Retry failed requests Retry transient failures such as `429`, `502`, `503`, and `504`. Use increasing delays with jitter and a maximum retry count. Do not automatically retry a write unless you know the operation is safe to repeat. Read the resource after an ambiguous failure before resubmitting a create or update. ```javascript retry.js theme={"theme":{"light":"github-light","dark":"github-dark"}} const retryableStatuses = new Set([429, 502, 503, 504]); export async function requestWithRetry(url, options = {}, maxAttempts = 5) { for (let attempt = 1; attempt <= maxAttempts; attempt += 1) { const response = await fetch(url, options); if (response.ok || !retryableStatuses.has(response.status)) { return response; } if (attempt === maxAttempts) { throw new Error(`KODE API request failed after ${maxAttempts} attempts: ${response.status}`); } const delayMs = Math.min(30_000, 500 * 2 ** (attempt - 1)); const jitterMs = Math.floor(Math.random() * 250); await new Promise((resolve) => setTimeout(resolve, delayMs + jitterMs)); } throw new Error("Retry loop ended unexpectedly."); } ``` ## Handle HTTP status codes | Status | Meaning | Recommended action | | - | - | - | | `200 OK` | The request succeeded. | Process the response. | | `201 Created` | The resource was created. | Store the returned identifier. | | `400 Bad Request` | The request is invalid. | Correct parameters or the request body. | | `401 Unauthorized` | Authentication failed or expired. | Request a new token and verify the assertion. | | `403 Forbidden` | The service lacks access. | Review building and operation permissions. | | `404 Not Found` | The resource is unavailable. | Verify the identifier and assigned access. | | `429 Too Many Requests` | A rate-limit window is exhausted. | Back off before retrying. | | `5xx` | KODE or an upstream service failed. | Retry transient failures with increasing delays. | Log the HTTP method, path, status, duration, and a correlation identifier when available. Redact tokens, assertions, private keys, and sensitive payload fields. ## Work with identifiers Treat resource identifiers as opaque strings. Do not parse identifiers or depend on their length and format. Retrieve identifiers from list or lookup endpoints before calling a dependent endpoint. For example, list buildings before requesting devices for a building. ## Work with time Use ISO 8601 timestamps where an endpoint accepts date and time strings. Timeseries ingestion endpoints can require Unix epoch timestamps. Preserve the source timestamp and timezone. Do not substitute the ingestion time for the measurement time. ## Next steps > [card] [Guides](/products/kode-api/guides/ingest-device-data) > > Follow end-to-end workflows for common integrations. > [card] [API reference](/products/kode-api/api-reference/introduction) > > Browse every endpoint and try requests in the playground. # Apply templates to points Source: https://docs.kodelabs.com/products/kode-api/guides/apply-templates-to-points Look up the ontology, discover point groups, apply a templating plan to the points of your devices, track the operation, and clear it through the KODE API. Templating gives the points of a device a meaning from the KODE ontology. You pick a canonical type for the devices, such as an air handler, and map each group of points to an ontology field, such as a discharge air temperature. KODE OS then names the points, sets their units, and sets the canonical type on the devices. You work in three phases. You look up what the ontology offers, you discover how the points of your devices group, and you send one plan that maps each group to a field. The API runs the plan as an operation that you track until it finishes. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. > [!WARNING] > > Applying and clearing a plan rewrites live data on every matched point: names, units, ontology fields, and enum maps. There is no undo call. Always validate first, check how many points the plan reaches, and test on a non-critical device before you automate it. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * A service account whose role allows **Get device and point templating** and **Manage device and point templating**. Get covers discovery and reading operations. Manage covers validate, apply, and clear, including a dry run. * The `buildingId` of the building, from [List buildings](/products/kode-api/api-reference/buildings/list-buildings). * The ids of the devices to template, from [List building devices](/products/kode-api/api-reference/devices/list-building-devices). Devices in that list carry `_id`. ## Look up the ontology The ontology endpoints do not depend on a building. They return the same catalog for your whole organization. **1. List canonical types** Call [List canonical types](/products/kode-api/api-reference/ontology/list-canonical-types) and pick the type that fits your devices. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/ontology/canonical-types" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` Send a canonical type exactly as listed. Values are case-sensitive, so `Ahu` does not match `ahu`. **2. List the fields of the type** Call [List fields for a canonical type](/products/kode-api/api-reference/ontology/list-fields-for-a-canonical-type). Add `unitSystem=METRIC` for metric units. The default is `IMPERIAL`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/ontology/canonical-types/ahu/fields?limit=200" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` For each field, read: * `field`: The identifier you send as `field` in a mapping. * `supportedKinds`: The point kinds the field can take, from `Number`, `Str`, and `Bool`. A field applies only to points of a supported kind. * `unit`: The unit `symbol` and `category`. A unit override must be in this category. * `requiredEnums` and `optionalEnums`: The values a `Bool` or `Str` point can map to. * `displayName`: The name the points get. A `{{prefix}}` or `{{suffix}}` in it is replaced with the instance number when a device has more than one point with the field. Use `kind` to filter by point kind, and `q` to search by field identifier. **3. List units, if you override a unit** A mapping can override the unit of a field. Call [List units by category](/products/kode-api/api-reference/ontology/list-units-by-category) and choose a unit from the same category as the field's `unit.category`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/ontology/units" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` **4. List connections, if you link devices** Templating does not use connections. You need them when you link devices that you template. [List connection keys](/products/kode-api/api-reference/ontology/list-connection-keys) returns every key. [List connections for a canonical type](/products/kode-api/api-reference/ontology/list-connections-for-a-canonical-type) returns the connections a device of one type can have, with `type` set to `INPUT` or `OUTPUT`, whether it accepts several devices in `multi`, and the canonical types allowed on the other end. A row's `key`, `multi`, and `type` are the `relationship` of a device reference. ## Template points **1. Discover the point groups** Send the devices to [Discover templating point groups](/products/kode-api/api-reference/templating/discover-templating-point-groups). Select 1 to 2,000 devices. Template devices of one canonical type together. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/templating/point-groups/query?limit=200" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "deviceIds": ["66f1a2b3c4d5e6f7a8b9c0d2"], "templateStatuses": ["NOT_TEMPLATED"] }' ``` A group holds the points of the selected devices that share a connector name, kind, writable flag, and unit (for `Number` points) or enum values (for `Bool` and `Str` points). Virtual and metadata points are not grouped. For each group, read: * `groupKey`: The key you send in a mapping. * `name`, `kind`, `writable`, `unitSymbol`, and `pointEnum`: The values that define the group. * `pointsCount`: How many points the group holds. * `templateStatus`: `NOT_TEMPLATED` or `TEMPLATED`. * `enumStatus`: `N_A`, `UNMAPPED`, `PARTIALLY_MAPPED`, or `MAPPED`. `N_A` means the group has no enum to map. * `currentFields`: The fields already applied, with a point count for each. You can filter the groups with `templateStatuses`, `kinds`, and `enumStatuses` in the body, and with `q` on the connector name. **2. Drill into a group** To review a group, or to pick single points, call [List points in a point group](/products/kode-api/api-reference/templating/list-points-in-a-point-group). Send the `groupKey` and the same `deviceIds`. Repeat the `deviceIds` parameter for each device. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/templating/point-groups/${GROUP_KEY}/points?deviceIds=66f1a2b3c4d5e6f7a8b9c0d2" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` Each point shows the device it belongs to, the `field` it carries now, and its `enumStatus`. A `groupKey` that does not match a group of those devices returns `400`. **3. Build the plan** A plan names the `canonicalType`, the `deviceIds`, and one mapping for each group or set of points you want to change. ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "canonicalType": "ahu", "deviceIds": ["66f1a2b3c4d5e6f7a8b9c0d2"], "requestId": "ahu-1-apply-2026-11-10", "validateOnly": true, "mappings": [ { "match": { "groupKey": "pg1.Yz3kR1a2B3c4D5e6F7g8H9" }, "field": "dischargeAirTemp", "overrides": { "displayName": "Supply Air Temp", "precision": 1 } }, { "match": { "pointIds": ["66f1a2b3c4d5e6f7a8b9c0d1"] }, "field": "supplyFanRunCmd", "enumMapping": { "action": "SET", "readMap": [ { "from": "Stopped", "to": "Off" }, { "from": "Running", "to": "On" } ] } } ] } ``` Each mapping has: * `match`: Send exactly one of `groupKey`, a tuple (`name`, `kind`, `unitSymbol`, `writable`, `pointEnum`), or `pointIds`. A point-level mapping takes precedence over a group mapping that covers the same point. * `field`: A `field` from the ontology, and a kind that fits the points. * `overrides`: Optional. `displayName`, `unit`, `precision`, `covTolerance`, `defaultInGraph`, `prefix`, `suffix`, and `dataInterval` replace the field's defaults. Without `prefix` and `suffix`, the server numbers repeated fields on a device. * `enumMapping`: Optional, for `Bool` and `Str` points. With `SET`, `readMap` pairs each of the point's own labels (`from`) with an enum value of the field (`to`). A `writeMap` pairs the other way and is accepted only for writable points. `UNSET` removes both maps. `KEEP` is the default and leaves them as they are. A plan holds at most 1,000 mappings and covers at most 5,000 distinct point ids. The values in the example are illustrative. Use the fields and enum values that the ontology returns for your canonical type. **4. Validate the plan** Post the plan to [Apply a templating plan](/products/kode-api/api-reference/templating/apply-a-templating-plan) with `validateOnly` set to `true`. Nothing is written. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/templating:apply" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data @plan.json ``` The response holds `validationReport`: * `valid`: `true` when no issue has `ERROR` severity. * `summary`: `matchedPoints` and `devicesAffected` show how many points and devices the apply would change. Check these numbers before you continue. `errors` and `warnings` count the issues. * `mappings[]`: The outcome of each mapping, in the order you sent them. `status` is `OK`, `WARNING`, or `ERROR`. * `issues`: Findings about the whole plan. * `unmappedGroups`: Groups of your devices that no mapping covers. * `etag`: A fingerprint of the resolved plan. Keep it for the next step. Each issue has a `code`, a `pointer` into your request, and a `message`. Fix every `ERROR` and validate again until `valid` is `true`. Warnings do not stop an apply. Common issues: | Code | Severity | Meaning | | - | - | - | | `UNKNOWN_FIELD` | Error | The field is not a field of this canonical type. | | `FIELD_KIND_MISMATCH` | Error | The field does not support the kind of the matched points. | | `UNIT_CATEGORY_MISMATCH` | Error | The unit override is not in the field's unit category. | | `UNKNOWN_GROUP_KEY` | Error | The `groupKey` matches no group of the selected devices. | | `DUPLICATE_GROUP_MAPPING` | Error | The same group is in more than one mapping. | | `DEVICES_TEMPLATED_UNDER_OTHER_CANONICAL` | Error | A device already has points templated under another canonical type. Clear it first. | | `MULTIPLE_CANONICAL_TYPES_IN_SELECTION` | Error | The selected devices are templated under more than one canonical type. | | `ENUM_MAPPING_ON_NUMBER` | Error | An enum map was sent for a `Number` point. | | `ENUM_MAP_KEY_NOT_IN_POINT_ENUM` | Error | A `readMap` `from` value is not one of the point's enum values. | | `ENUM_MAP_VALUE_NOT_ALLOWED` | Error | A `to` value is not an enum value of the field. | | `WRITE_MAP_ON_READONLY_POINT` | Error | A `writeMap` was sent for points that are not writable. | | `PLAN_TOO_LARGE` | Error | The plan has too many mappings, devices, or points. | | `NO_MATCH` | Warning | The mapping matched no points. | | `REQUIRED_ENUMS_UNMAPPED` | Warning | Some required enum values of the field are not mapped. | | `ENUM_MAPPING_RECOMMENDED` | Warning | The field has required enum values and the points have no read map. | **5. Apply the plan** Send the same body with `validateOnly` removed, and add the `etag` from the report: ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "canonicalType": "ahu", "deviceIds": ["66f1a2b3c4d5e6f7a8b9c0d2"], "requestId": "ahu-1-apply-2026-11-10", "etag": "sha256:9f86d0818...", "mappings": [ "...same as before" ] } ``` The response holds `operation`. Keep the last segment of `operation.name` as the `operationId`. * Only `validateOnly: true` makes a dry run. If you leave `validateOnly` out, the call starts a real run. * The `requestId` is unique per building. If your request times out, send it again with the same `requestId` and body. The API returns the operation it already started instead of starting a second one. A different body with the same `requestId` returns `400`. * If the plan changed since you validated it, the `etag` no longer matches and the call returns `400`. Validate again to get a new `etag`. * The API does not stop two runs from touching the same points. The last write wins. **6. Track the operation** Call [Get a templating operation](/products/kode-api/api-reference/templating/get-a-templating-operation) every few seconds until `done` is `true`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/templating/operations/${OPERATION_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` This response is the operation itself. It is not wrapped in `operation`. Read `metadata.state`: | State | Meaning | | - | - | | `QUEUED` and `RUNNING` | The run has not finished. `metadata.progress` shows a percentage that updates after each batch. | | `SUCCEEDED` | The run finished. `response.matchedPoints` and `response.devicesAffected` show what it changed. | | `FAILED` | The run stopped with an error. `error.code` and `error.message` explain why. | | `STALLED` | The run is `RUNNING` but has stopped reporting progress. It is not finished, so `done` stays `false`. | Use `done`, not `progress`, to detect that a run is finished. After `SUCCEEDED`, graphics, device references, and device linking keep updating in the background, so they can lag behind the point data for a short time. Add `fields=done,metadata` to return less data while you poll. **7. Clear the templating** To remove the templating from points, call [Clear a templating plan](/products/kode-api/api-reference/templating/clear-a-templating-plan). It takes the same body as apply, including `requestId`, `etag`, and `validateOnly`. A clear mapping needs only `match`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/templating:clear" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "canonicalType": "ahu", "deviceIds": ["66f1a2b3c4d5e6f7a8b9c0d2"], "requestId": "ahu-1-clear-2026-11-10", "validateOnly": true }' ``` * With `mappings`, only the points the mappings match are cleared. * Without `mappings`, or with an empty list, **every** point templated under `canonicalType` on the selected devices is cleared. Validate first. `summary.matchedPoints` and `summary.devicesAffected` show how many points and devices a real clear reaches. Validate, then send the clear without `validateOnly`, and track the operation as before. ## What apply and clear change Both calls change stored point and device data. They do not send values to the equipment. | | Apply | Clear | | - | - | - | | Point name | Set to the field's display name, with `{{prefix}}` and `{{suffix}}` replaced by the instance numbers. | Reset to the connector name. | | Point display name | Set to the field's display name. | Reset to the connector name. | | Ontology fields on the point | Sets `field`, `prefix`, `suffix`, and the field's measurement, component, descriptor, point type, aggregation, bounds, precision, COV tolerance, and graphing defaults. Your `overrides` replace the defaults. | Removes them. | | Unit | Set to the field's unit, or to your `unit` override. | Reset to the unit the connector reported. | | Enum maps | Follows `enumMapping`: `SET` replaces the read and write maps, `UNSET` removes them, `KEEP` leaves them. | Removes them. | | Canonical type | Set on the matched devices and their points. | Removed from a device that has no templated point left, and from its points. A cleared point keeps it while its device has other templated points. | | Entities | Set on the devices and points from the ontology. | Updated on the devices. Removed from the cleared points. | Some things apply and clear leave alone: * Virtual points. Apply does not create, change, or template virtual points, and the point groups do not list them. * Points on platform-managed connectors. * The point's value, its connector, and the write commands it accepts. Clear does not remove the `dataInterval` that apply set. * Any point that the plan does not match. After a run succeeds, KODE OS also updates device graphics, device references, and device linking for the changed devices. This runs in the background and can finish after the operation reports `SUCCEEDED`. ## Limits | Limit | Value | | - | - | | Devices per request | 2,000 | | Mappings per plan | 1,000 | | Distinct point ids per plan | 5,000 | | Groups, canonical types, fields, and `limit` per page | `limit` up to 200 | | `requestId` and `etag` length | 128 characters | Templating requests also count toward your [rate limits](/products/kode-api/fundamentals#rate-limits). # Connect your own devices Source: https://docs.kodelabs.com/products/kode-api/guides/connect-your-own-devices Create a KODE API connector in a building, ingest your devices and points, and track the ingest jobs through the KODE API. A KODE API connector lets you bring devices and points from your own system into a building in KODE OS. You create the connector, send the devices and points you want, and follow each request as a background job. This guide takes you from a building to ingested devices and points. To send point values after the points exist, continue with [Ingest device and point data](/products/kode-api/guides/ingest-device-data). Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. > [!WARNING] > > Every request in this guide that is not a read adds data to a real building in your organization. Ingested devices and points appear in KODE OS next to the rest of the building data. Use a test building first. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * A service account whose KODE OS role allows the actions you use: | Step | Actions | | - | - | | Read buildings, jobs, and connectors | `Get Buildings`, `Get connectors` | | Create a building | `Create building` | | Set the status of a building | `Publish or unpublish building` | | Create a connector | `Create KODE API connector` | | Ingest devices and points | `Ingest connector devices`, `Ingest connector points` | ## Choose a building You can use a building that already exists or create one. > [tab] Use an existing building > > Call [List buildings](/products/kode-api/api-reference/buildings/list-buildings) and note the `_id` of the building to use as `buildingId`. > > ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} > curl "https://api.kodelabs.com/kodeos/api/v1/buildings" \ > --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" > ``` > [tab] Create a building > > Send the required fields to [Create a building](/products/kode-api/api-reference/buildings/create-a-building). > > ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} > curl --request POST \ > "https://api.kodelabs.com/kodeos/api/v1/buildings" \ > --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ > --header "Content-Type: application/json" \ > --data '{ > "name": "API test building", > "primaryFunction": "Office", > "baseTemp": 68, > "address": { > "address1": "1600 Amphitheatre Parkway", > "city": "Mountain View", > "state": "CA", > "zip": "94043", > "country": "US" > } > }' > ``` > > Keep the `_id` from the response as `buildingId`. > > * `name` is up to 50 characters and must be unique in your organization, ignoring case. A repeated name returns `409`. > > * `primaryFunction` must be one of the values listed on the endpoint page, with the same capitalization. Any other value returns `400`. > > * `baseTemp` is in °F. > > * The API looks up the address. An address that cannot be located returns `400`. > > * A new building is unpublished. To change it, call [Set the status of a building](/products/kode-api/api-reference/buildings/set-the-status-of-a-building) with `PUBLISHED` or `UNPUBLISHED`. > > > [!WARNING] > > > > The API cannot delete a building, and the name stays taken until someone removes the building in KODE OS. Create buildings sparingly, and ask your KODE project team to remove a test building when you are done. > > > [!NOTE] > > > > A new building has every product turned off, so calls that name it return `403` until the `api` product is enabled for it. The API cannot enable products. Your KODE project team enables the `api` product for a new building by hand. Ask them to enable it before you continue, and allow for that step if you automate building creation. > > To change the building later, use [Update a building](/products/kode-api/api-reference/buildings/update-a-building). Fields you leave out keep their stored values. You cannot clear a field. If a call on the building returns `403`, the building does not exist, is not available to your service account, or has no `api` product enabled. The API gives the same answer in each case. ## Ingest devices and points **1. Check for an existing connector** Call [List connectors](/products/kode-api/api-reference/connectors/list-connectors). The list holds every connector in the building. A connector you can ingest into has `integrationType` set to `API_KODE`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/connectors" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` If one fits, note its `_id` as `connectorId` and go to the ingest steps. Otherwise create one. **2. Create a KODE API connector** Send a `name` to [Create a KODE API connector](/products/kode-api/api-reference/connectors/create-a-kode-api-connector). ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/connectors/kode-api" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "name": "Building automation system" }' ``` Keep the `_id` from the response as `connectorId`. The name is free text. The API does not reject a repeated name, so a second request with the same name creates a second connector. The integrations endpoints call a connector a data source, and its `_id` is the `datasourceId` they use. **3. Ingest the devices** Send your devices to [Ingest devices through a connector](/products/kode-api/api-reference/connectors/ingest-devices-through-a-connector). Use stable identifiers from your system for `deviceExternalId`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/connectors/${CONNECTOR_ID}/ingest/devices" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "items": [ { "deviceExternalId": "ahu-01", "deviceExternalPath": "/site/roof/ahu-01", "deviceName": "AHU-01", "deviceLocation": "Roof" }, { "deviceExternalId": "ahu-02", "deviceExternalPath": "/site/roof/ahu-02", "deviceName": "AHU-02" } ] }' ``` The response has status `202` and holds a job: ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "_id": "6710a1f4c2d0e5a9b8f3c7d1", "name": "Ingest connector devices", "status": "PROCESSING" } ``` Keep the job `_id` as `jobId`. Send up to 1,000 devices in one request. Sending a `deviceExternalId` again updates the name and location of that device. It does not create a duplicate. **4. Wait for the devices job** Call [Get a job](/products/kode-api/api-reference/buildings/get-a-job) every few seconds until `status` is `COMPLETED` or `FAILED`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/jobs/${JOB_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` | `status` | What to do | | - | - | | `PENDING` or `PROCESSING` | Wait and call again. | | `COMPLETED` | Go to the next step. | | `FAILED` | Read `errorMessage`, fix the request, and send it again. | Polling counts toward your [rate limits](/products/kode-api/fundamentals#rate-limits), so wait a few seconds between calls. **5. Ingest the points** Points belong to devices, so ingest the devices first. Each point item names its parent device with the same `deviceExternalId` and `deviceExternalPath` you sent in the previous step. Send the items to [Ingest points through a connector](/products/kode-api/api-reference/connectors/ingest-points-through-a-connector). ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/connectors/${CONNECTOR_ID}/ingest/points" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "items": [ { "deviceExternalId": "ahu-01", "deviceExternalPath": "/site/roof/ahu-01", "pointExternalId": "supply-air-temp", "pointExternalPath": "/site/roof/ahu-01/supply-air-temp", "pointName": "Supply Air Temp", "pointKind": "Number", "pointMinVal": 0, "pointMaxVal": 150 }, { "deviceExternalId": "ahu-01", "deviceExternalPath": "/site/roof/ahu-01", "pointExternalId": "fan-command", "pointExternalPath": "/site/roof/ahu-01/fan-command", "pointName": "Fan Command", "pointKind": "Bool", "pointWritable": true } ] }' ``` Use these rules: * `pointKind` is `Number`, `Str`, or `Bool`, with that capitalization. * `pointUnit` is the `_id` of an ontology unit. An unknown unit returns `400`. * `pointEnum` is one comma-separated string, such as `off,on,auto`. * `pointMinVal` cannot be higher than `pointMaxVal`. * `pointWritable` defaults to `false`. If a parent device was not ingested on this connector, the request returns `400` and names the missing `deviceExternalId` values. Fix the request and send it again. Then wait for the job as you did for the devices. **6. Confirm the result** A completed job tells you that it ran to the end. It does not list what it stored. Read the data back: * [List building devices](/products/kode-api/api-reference/devices/list-building-devices) shows the ingested devices. * [List building points](/products/kode-api/api-reference/points/list-building-points) shows the ingested points and their parent devices. * [Get a connector](/products/kode-api/api-reference/connectors/get-a-connector) shows the connector. * [Get connector status](/products/kode-api/api-reference/connectors/get-connector-status) shows the last connection status KODE OS recorded. A new KODE API connector has none, so the response is an empty object. Ingesting devices or points does not change it. ## Send point values After the points exist, send their values with the timeseries endpoints. See [Ingest device and point data](/products/kode-api/guides/ingest-device-data), which covers current values, history, and rate limits. ## Update what you sent Send a device again with the same `deviceExternalId` to change its name or location. Send a point again with the same `pointExternalId` and the API does not create a second point. ## Limits | Limit | Value | | - | - | | Devices per ingest request | 1,000 | | Points per ingest request | 1,000 | | Building `name` length | 50 characters | | `pointName` length | 255 characters | | Connectors that accept ingest | KODE API connectors (`integrationType` `API_KODE`) only | Ingest requests count toward your [rate limits](/products/kode-api/fundamentals#rate-limits). ## Troubleshooting | Response | Likely cause | | - | - | | `403` | The building does not exist or is not assigned to your service account, the `api` product is not enabled for it, or the role lacks the action. A building you just created needs your KODE project team to enable the `api` product first. | | `404` on a connector or job | The id is not in this building. A connector or job of another building returns `404`. | | `400` on ingest points | A parent device, a unit, or a `pointKind` is not valid, or a minimum is higher than its maximum. Read `error.message`. | | `400` on ingest | The connector is not a KODE API connector, `items` is empty or holds more than 1,000 items, or an item lacks a required member. | | `409` on create or update | Another building in your organization has this name. | | `409` on a status change | The building already has this status. | # Ingest device and point data Source: https://docs.kodelabs.com/products/kode-api/guides/ingest-device-data Create devices and points on a KODE API data source, then send current and historical point values. Send data from your system into KODE OS by registering devices on a KODE API data source and posting point values. KODE OS then treats your data like any other connected building data. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * A `buildingId` from [List buildings](/products/kode-api/api-reference/buildings/list-buildings). * A data source with `apiType` set to `API_KODE` on that building. Ask your KODE project team to create one if it does not exist. ## Send device data **1. Find your data source** Call [List building data sources](/products/kode-api/api-reference/data-sources/list-building-data-sources) and note the `_id` of the data source whose `apiType` is `API_KODE`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/integrations/datasources" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` **2. Create devices and points** Register each device with its points. Use stable identifiers from your system, because sending the same `id` again updates the existing device instead of creating a duplicate. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/integrations/datasources/${DATASOURCE_ID}/devices/batch" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "devices": [ { "id": "ahu-01", "name": "AHU-01", "points": [ { "pointId": "supply-air-temp", "name": "Supply Air Temp", "kind": "Number", "unit": "°F" }, { "pointId": "fan-status", "name": "Fan Status", "kind": "Bool" } ] } ] }' ``` The response reports how many devices and points were created or updated: ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "deviceSize": 1, "pointsSize": 2 } ``` **3. Send current values** Post values grouped by device. Set `timestamp` to the Unix epoch time of the measurement, or `0` to use the current time. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/integrations/datasources/${DATASOURCE_ID}/timeseries" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "data": [ { "deviceId": "ahu-01", "points": [ { "id": "supply-air-temp", "value": 55.4, "timestamp": 1759840200, "status": "ok" }, { "id": "fan-status", "value": true, "timestamp": 1759840200, "status": "ok" } ] } ] }' ``` **4. Confirm the values arrived** Call [List latest point values](/products/kode-api/api-reference/timeseries/list-latest-point-values) with the KODE OS point identifiers returned by [List building points](/products/kode-api/api-reference/points/list-building-points). ## Choose a timeseries endpoint | Endpoint | Use it when | | - | - | | [Send timeseries for a data source](/products/kode-api/api-reference/timeseries/send-timeseries-for-a-data-source) | You send values for many devices at once. | | [Send timeseries for a device](/products/kode-api/api-reference/timeseries/send-timeseries-for-a-device) | You send values for one device at a time. | | [Send historical values for a point](/products/kode-api/api-reference/timeseries/send-historical-values-for-a-point) | You backfill history for a single point. | ## Design for reliable ingestion * Batch values to stay within the [rate limits](/products/kode-api/fundamentals#rate-limits). Five requests per second is the burst ceiling. * Send the measurement time, not the time your service processed the value. * Use `status` to report `fault`, `down`, or `no_value` instead of skipping a reading. * Re-run device creation when your system adds points. Existing devices update in place. # Manage users Source: https://docs.kodelabs.com/products/kode-api/guides/manage-users List the users of your organization, create or invite a user, give and change app access, activate or deactivate a user, and remove access or delete a user through the KODE API. Use the users operations to manage who can sign in to your organization and what they can open. A user has an organization role and, in KODE OS, a KODE OS role. You set the organization role when you create, invite, or update the user. You give app access in a separate step. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. > [!WARNING] > > Some of these requests send email to the person you add, and a delete cannot be undone. Test with an address you own, and on a non-production environment first. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * A service account whose role allows the user actions you call: list, get, create, invite, update, delete, assign app, update KODE OS role, and unassign app. Each operation needs its own action. * For app access, the `buildingId` of each building the user can open. See [List buildings](/products/kode-api/api-reference/buildings/list-buildings). You see and change only the users of your own organization. A `userId` from another organization returns `404`. ## How users and app access fit together | Field | Meaning | | - | - | | `role` | The organization role, for example `CLIENT_ADMIN` or `CLIENT_RESTRICTED_ACCESS`. | | `memberType` | `INTERNAL` for a user you create. `GUEST` for a user you invite from another organization. | | `active` | Whether the account is enabled. You set it when you create the user, and you can change it later. | | `invitationStatus` | `PENDING` or `ACCEPTED` for a guest. Absent for an internal user. | | `assignedInApps` | The apps the user can access. Each entry has `appId`, the app `role`, and `assignmentStatus`. | A new user has no app access. The organization role and the KODE OS role are separate, and each has its own operation to change it. ## List users Call [List users](/products/kode-api/api-reference/users/list-users). Each item in `data` is a user, with the apps the user can access in `assignedInApps`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/users?limit=50&page=1" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` Add filters to narrow the list. A user must match every filter you send. | Parameter | Use | | - | - | | `q` | Search by email address. The match is not case-sensitive. | | `role` | Organization role. Repeat it to match any of several roles. | | `active` | `true` for active users, `false` for inactive users. | | `appId` | Users who have this app, for example `bms`. Repeat it to match any of several apps. | | `memberType` | `INTERNAL` or `GUEST`. The value is case-sensitive. | Users come back by `_id`, highest first. Use `asc` or `dsc` to sort by another field, such as `email`. Stop requesting pages when `page` equals `pageCount`. See [pagination](/products/kode-api/fundamentals#pagination). Keep the `_id` of the user you want. Every other operation takes it as `userId`. ## Create or invite a user Choose the operation by where the person belongs. | | [Create a user](/products/kode-api/api-reference/users/create-a-user) | [Invite a user](/products/kode-api/api-reference/users/invite-a-user) | | - | - | - | | For | A person who belongs to your organization. | A person from another organization. | | `memberType` | `INTERNAL` | `GUEST` | | You send | `firstName`, `lastName`, `email`, `role`, `active`. Optionally `phone` and `position`. | `trustedOrganizationId`, `email`, `role`. Optionally `position`. | | `active` | You choose `true` or `false`. | Always `true`. | | Email | Sent when `active` is `true`. | Sent only when the invitee already has an account in the organization you name. | ### Create a user ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/users" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "firstName": "Jordan", "lastName": "Lee", "email": "jordan.lee@example.com", "role": "CLIENT_RESTRICTED_ACCESS", "active": false, "phone": "+14155552671", "position": "Facilities coordinator" }' ``` The response is `200` and holds the new user, with its `_id`. > [!WARNING] > > With `active` set to `true`, KODE emails the user a link to set a password. With `active` set to `false`, the account is created disabled and no email is sent. To enable the account later, [update the status of the user](#activate-or-deactivate-a-user). Keep these rules in mind: * The email address must be unique in your organization, in any letter case. KODE stores it in lower case. A duplicate returns `400`. * `firstName` and `lastName` can have up to 40 characters, and `position` up to 200. * `phone` must be an international number that starts with `+`. * Values that contain HTML tags are stored HTML-escaped. ### Invite a guest ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/users/invite" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "trustedOrganizationId": "67c95f0aa1b2c3d4e5f60718", "email": "guest@example.com", "role": "CLIENT_RESTRICTED_ACCESS", "position": "Contractor" }' ``` The response is `200` and holds the guest, with `memberType` set to `GUEST`, `active` set to `true`, and `invitationStatus` set to `PENDING`. The guest has no name. If `trustedOrganizationId` does not match an organization, or the email already belongs to a user, the request fails with `400`. ## Give app access to a user App access is asynchronous. You send the assignment, KODE finishes it in the background, and you read the user to see the result. Only the `bms` app can be assigned through the API. **1. Assign the app** Call [Assign an app to a user](/products/kode-api/api-reference/users/assign-an-app-to-a-user) with `bms` as the `appId`. Send the KODE OS role in `role`. Use a role of your organization's `bms` app, for example `ViewOnly`. To limit access to some buildings, send their IDs in `buildingIds`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}/apps/bms" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "role": "ViewOnly", "buildingIds": ["67c960faffaa42223163099e"] }' ``` The response is `202` with no body. That means KODE accepted the request, not that access is ready. A user who already has the app gets `400`. **2. Wait until the assignment finishes** Call [Get a user](/products/kode-api/api-reference/users/get-a-user) until the `bms` entry in `assignedInApps` reaches a final status. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` Read `assignedInApps[].assignmentStatus`: | Status | Meaning | | - | - | | `INITIALIZING` | KODE accepted the assignment and has not started it. | | `PROCESSING` | KODE is setting up the access. | | `SUCCEEDED` | The user has access to the app. | | `FAILED` | The assignment did not finish. | | `PENDING` | The user is a guest who has not accepted the invitation. Nothing runs until the guest accepts. | Poll every few seconds and stop on `SUCCEEDED` or `FAILED`. > [!NOTE] > > The buildings you send in `buildingIds` are not returned by the API. `assignedInApps` lists the app, the role, and the status only. > [!WARNING] > > Assigning an app to an active user can send that user an email. ## Change a role A user has two roles. Use the operation that matches the one you want to change. | To change | Call | | - | - | | The organization role, `role` on the user | [Update a user](/products/kode-api/api-reference/users/update-a-user) | | The role in an app, `assignedInApps[].role` | [Update the KODE OS role of a user](/products/kode-api/api-reference/users/update-the-kode-os-role-of-a-user) | ### Update a user ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request PUT \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "firstName": "Jordan", "position": "Facilities lead" }' ``` This call changes `firstName`, `lastName`, `phone`, `position`, and the organization `role`. You cannot change `email`. To change `active`, [update the status of the user](#activate-or-deactivate-a-user). Setting `role` to `CLIENT_ADMIN` returns `403`. ### Update the KODE OS role The user must already have the app, and the assignment must be finished. Wait for `SUCCEEDED` or `FAILED` first. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request PUT \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}/apps/bms" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "role": "Engineering" }' ``` The response is `204` with no body. This changes the role in the app only, not the organization role. If the user does not have the app, the request fails with `400` and the message "App not found". ## Remove app access Call [Remove app access from a user](/products/kode-api/api-reference/users/remove-app-access-from-a-user). The user stays in your organization. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request DELETE \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}/apps/bms" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` The response is `204` with no body. Read the user to confirm that the `bms` entry is gone from `assignedInApps`. If the user does not have the app, the request fails with `400` and the message "App not found". You can remove access that is still `PENDING`. ## Activate or deactivate a user Call [Update the status of a user](/products/kode-api/api-reference/users/update-the-status-of-a-user) with `active` set to `true` or `false`. The user stays in your organization. > [!WARNING] > > The first time KODE activates a user, it sends an account email with a link to set a password. Check the email address before you send the request. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request PUT \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}/status" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "active": false }' ``` The response is `200` and holds the updated user. If the user already has the status you sent, the request fails with `400` and the message "Invalid status update". To take away app access and keep the account enabled, remove the app access as in the previous section. ## Delete a user To remove the user, call [Delete a user](/products/kode-api/api-reference/users/delete-a-user). > [!WARNING] > > A delete is permanent and cannot be undone. The user and the user's app access are removed. The delete succeeds even while an app assignment is still being set up. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request DELETE \ "https://api.kodelabs.com/kodeos/api/v1/users/${USER_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` The response is `204` with no body. Read the user afterwards to confirm: it returns `404`. A second delete of the same user also returns `404`. No email is sent. If you later create a user with the same email address, the new user gets the same `_id`. ## Handle errors Error responses hold an `error` object with a `code`, a `message`, and, for field checks, `fields`. | Status | When | What to do | | - | - | - | | `400` | A field is missing, too long, or invalid. The email is already in use. The app is already assigned, or the user does not have it. The `appId` is not `bms`. The user already has the status you sent. | Read `error.message` and `error.fields`, then correct the request. | | `403` | The service account is not allowed to do this, or to grant this role. | Check the service account's role. | | `404` | The `userId` does not exist in your organization. | List the users again and use a current `_id`. | After a timeout or a `5xx` on a create or invite, search the list with `q` before you send the request again, because the user can already exist. See [retry failed requests](/products/kode-api/fundamentals#retry-failed-requests). ## Limits | Field | Limit | | - | - | | `firstName`, `lastName` | 40 characters | | `position` | 200 characters | | `phone` | International number that starts with `+` | | `limit` on the list | 1 to 200, default 50 | | Apps you can assign | `bms` only | # Create and manage work orders Source: https://docs.kodelabs.com/products/kode-api/guides/manage-work-orders Create, update, and sync AssetOps work orders through the KODE API, including lookups, comments, and attachments. Use the work order endpoints to raise AssetOps work orders from external systems and keep them in sync. Each work order belongs to a building and references categories, priorities, and people from that building. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * A `buildingId` from [List buildings](/products/kode-api/api-reference/buildings/list-buildings). * AssetOps enabled for the building. ## Create a work order **1. Look up valid values** Work orders reference identifiers that must exist in the building. Get them from the lookup endpoints: | Field | Lookup endpoint | | - | - | | `category`, `issueType` | [List categories and issue types](/products/kode-api/api-reference/work-orders/list-categories-and-issue-types) | | `priority` | [List priorities](/products/kode-api/api-reference/work-orders/list-priorities) | | `vendor` | [List vendors](/products/kode-api/api-reference/work-orders/list-vendors) | | `team` | [List teams](/products/kode-api/api-reference/work-orders/list-teams) | | `assignees` | [List assignees](/products/kode-api/api-reference/work-orders/list-assignees) | Cache these values and refresh them periodically. They change less often than work orders. **2. Create the work order** Send the work order to [Create a work order](/products/kode-api/api-reference/work-orders/create-a-work-order). The API accepts `CORRECTIVE_MAINTENANCE` and `SERVICE_REQUEST` as the `workType`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/assetops/work-orders" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "workType": "CORRECTIVE_MAINTENANCE", "title": "Replace AHU-01 supply fan belt", "description": "Belt is worn and slipping during morning startup.", "startDate": "2026-10-08T09:00:00", "dueDate": "2026-10-10T17:00:00", "category": { "id": "6501c2d3e4f5a6b7c8d9e0f1" }, "issueType": { "id": "6501c2d3e4f5a6b7c8d9e0f2" }, "priority": { "id": "6501c2d3e4f5a6b7c8d9e0c4" }, "assignees": [{ "email": "dana.ruiz@example.com" }], "linkedSource": { "identifier": "FAULT-88231", "type": "EXTERNAL" } }' ``` Store the returned `id` and `identifier`. Set `linkedSource.identifier` to the record ID in your system so that you can match work orders later. **3. Attach files** Upload photos or documents with [Upload attachments](/products/kode-api/api-reference/work-orders/upload-attachments) as multipart form data. If your system already holds base64 content, use [Upload base64 attachments](/products/kode-api/api-reference/work-orders/upload-base64-attachments). Both endpoints accept up to 10 files per request. ## Update a work order [Update a work order](/products/kode-api/api-reference/work-orders/update-a-work-order) replaces the editable details. Optional fields you leave out, such as `description`, `vendor`, `team`, and `assignees`, can be cleared. To change one field safely: 1. Get the current work order with [Get a work order](/products/kode-api/api-reference/work-orders/get-a-work-order). 2. Change the field you need. 3. Send the complete body back. You cannot change `workType` or `linkedSource` after creation. If you omit `priority`, the current priority stays in place. ## Sync work orders with another system To keep an external system up to date, poll for changes instead of reading every work order: * Call [List work orders](/products/kode-api/api-reference/work-orders/list-work-orders) with `updatedAtFrom` set to the time of your last sync. * Call [List building comments](/products/kode-api/api-reference/work-orders/list-building-comments) with the same filter to collect new comments. * Filter by `sourceType` to return only work orders your integration created. Store the sync time only after you process every page, so a failure does not skip changes. # Organize devices and points Source: https://docs.kodelabs.com/products/kode-api/guides/organize-devices-and-points Link devices to each other and to spaces, copy points, group points on virtual devices, update or delete devices and points in batches, and see what a delete removes. Once devices and points exist in a building, you can organize them. You link a device to the devices it feeds or is fed by, link it to the spaces it serves or measures, copy a point onto another device, and group points on a virtual device. You can also change or delete devices and points one at a time or in batches. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. > [!WARNING] > > Deletes are permanent and cascade to points, copies, and links. There is no undo. Read [What a delete removes](#what-a-delete-removes) first, and test on a device you created for the purpose. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * The `buildingId` of the building, from [List buildings](/products/kode-api/api-reference/buildings/list-buildings). * The ids of the devices, points, and spaces you want to work with. [List building devices](/products/kode-api/api-reference/devices/list-building-devices) and [List building points](/products/kode-api/api-reference/points/list-building-points) return them. * A service account whose role allows creating, updating, and deleting devices and points in the building. ## Link devices to each other A device reference links one device to another, for example an air handler to the VAV boxes it feeds. You add the link from one device, and KODE OS stores the reverse link on the other device. **1. Find the connection to use** Call [List connections for a canonical type](/products/kode-api/api-reference/ontology/list-connections-for-a-canonical-type) with the canonical type of the device you link from. Each row has the `key`, `multi`, and `type` you send as `relationship`, and `canonicalTypes` lists the types of devices it can link to. Both devices need an ontology applied. A device without one is refused with `400`. **2. Add the link** The device in the path is the one you link from. Send the ids of the devices to link to. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/devices/${DEVICE_ID}/references" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "relationship": { "key": "feeds", "multi": true, "type": "OUTPUT" }, "referencedDeviceIds": ["67c977317437671625264e03"] }' ``` [Add device references](/products/kode-api/api-reference/devices/add-device-references) returns `204` with an empty body. It refuses, with `400`, a link where a device references itself, a device is already linked, or the link would create a loop or reverse an existing link. **3. Read the links back** Call [List device references](/products/kode-api/api-reference/devices/list-device-references) on either device. Each item has the linked `device`, the `key`, the `type`, and the `ontology` of the linked device. The two devices show opposite `type` values, `OUTPUT` on the device that feeds and `INPUT` on the device that is fed. Check the list after you add links. The response of the add request does not list what was stored. **4. Remove a link** Send the linked device ids to [Remove device references](/products/kode-api/api-reference/devices/remove-device-references). ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "referencedDeviceIds": ["67c977317437671625264e03"] } ``` The link is removed from both devices. Neither device is deleted. ## Link a device to spaces A space reference links a device to a space it serves or measures. You send the space ids. KODE OS decides whether each link is `serves` or `measures`. **1. Add the links** ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/devices/${DEVICE_ID}/space-references" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "referencedSpaceIds": ["67c977317437671625264e10"] }' ``` [Add device space references](/products/kode-api/api-reference/devices/add-device-space-references) returns `204` with an empty body. The device needs an ontology applied. Repeating an id does not add a second link. **2. List the links** [List device space references](/products/kode-api/api-reference/devices/list-device-space-references) returns the `space` and the `key` of each link. Use `category` to narrow the list to `Level`, `SpaceUnit`, or `Zone` spaces. **3. Remove links** Send the space ids to [Remove device space references](/products/kode-api/api-reference/devices/remove-device-space-references). The device and the spaces are not deleted. ## Copy points to other devices A point copy puts a point on another device without a second ingest. The copy mirrors its source: it has its own `id` and sits on the device you chose, and [Get a point](/products/kode-api/api-reference/points/get-a-point) shows the live value of the source. **1. Send the copy request** Send the points and the devices. KODE OS creates one copy for each pair, up to 50 pairs in a request. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/points/copies" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "pointIds": ["67c977317437671625264e21"], "deviceIds": ["67c977317437671625264e05"] }' ``` These rules apply to the request. If one is broken, the request is refused with `400` and nothing is written: * The points must be origin points on one device. A copy cannot be copied. * The target devices must be origin or virtual devices, and not the device or base device of a source point. **2. Check each pair** [Copy points to devices](/products/kode-api/api-reference/points/copy-points-to-devices) returns one item per pair, in request order. `status` is `CREATED`, `COPY_EXISTS` when the copy was already there, or `LIMIT_REACHED` when the source has 200 copies. You can repeat a request safely: existing copies are not created again. **3. Keep the copy ids** Each `CREATED` item in the response carries the `_id` of the new copy. To find copies later, call [List point copies](/products/kode-api/api-reference/points/list-point-copies) with `sourcePointId` and `deviceId`. Each item has the copy `_id`, its `device`, and its `source`. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/points/copies?sourcePointId=${POINT_ID}&deviceId=${DEVICE_ID}" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` Copies are written device by device. If a request fails part way, the copies already written stay. List the copies, then send the request again. Deleting a copy with [Delete a point](/products/kode-api/api-reference/points/delete-a-point) removes only the copy. Deleting the source point removes all of its copies. ## Group points on a virtual device A virtual device holds points that come from other devices, for example the supply and return temperatures of one air handler shown together. You have two ways to put points on it. **1. Create the virtual device** Send a `name`. `typeId` and `locatedInSpaceId` are optional. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/virtual-devices" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "name": "Rooftop summary" }' ``` [Create a virtual device](/products/kode-api/api-reference/virtual-devices/create-a-virtual-device) returns `201` with the new device. The device id is `id`, and `pointsCount` is `0`. Sending the same name again creates a second device. **2. Add points** To show points of a real device without moving them, use the copy request above with the virtual device in `deviceIds`. To move points that sit on a pseudo device, call [Attach points to a virtual device](/products/kode-api/api-reference/virtual-devices/attach-points-to-a-virtual-device) with up to 200 `pointIds`. The points keep their `id` and trend data, and their modeling is reset, so apply modeling after you attach. **3. Take points off** [Detach points from a virtual device](/products/kode-api/api-reference/virtual-devices/detach-points-from-a-virtual-device) returns origin points to their base device and lists them in `detached`. Copies cannot go back, so they are deleted and listed in `deletedCopies`. The request is all or nothing: every point must be on the device. Deleting a virtual device with [Delete a device](/products/kode-api/api-reference/devices/delete-a-device) deletes the copies on it. ## Update many devices or points Use a batch update when many devices or points need different changes. Both endpoints take up to 1,000 `items`. Each item has the `id` and the fields to change, and fields you leave out keep their value. **1. Send the batch** ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/points/batch-update" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data '{ "items": [ { "id": "67c977317437671625264e21", "name": "Supply Air Temp" }, { "id": "67c977317437671625264e22", "precision": 1 } ] }' ``` Use [Update points in a batch](/products/kode-api/api-reference/points/update-points-in-a-batch) for points and [Update devices in a batch](/products/kode-api/api-reference/devices/update-devices-in-a-batch) for devices. Send each `id` once. The response is a job with the status `PROCESSING`. **2. Poll the job** Call [Get a job](/products/kode-api/api-reference/buildings/get-a-job) with the job `_id` every few seconds until `status` is `COMPLETED`, `FAILED`, or `CANCELED`. **3. Read the result** The job checks that every id exists in the building. If any id is unknown or belongs to another building, the job ends with `FAILED` and nothing is changed. On `COMPLETED`, read the devices or points to confirm the new values. To change one device or point, use [Update a device](/products/kode-api/api-reference/devices/update-a-device) or [Update a point](/products/kode-api/api-reference/points/update-a-point). ## Delete devices and points | To delete | Use | | - | - | | One device | [Delete a device](/products/kode-api/api-reference/devices/delete-a-device) | | Up to 1,000 devices | [Delete devices in a batch](/products/kode-api/api-reference/devices/delete-devices-in-a-batch) | | One point or one copy | [Delete a point](/products/kode-api/api-reference/points/delete-a-point) | | Up to 1,000 points | [Delete points in a batch](/products/kode-api/api-reference/points/delete-points-in-a-batch) | The single deletes return `204` with an empty body. The batch deletes return a job. Poll it as described in the previous section. > [!WARNING] > > A batch delete skips ids that do not match an object in the building, and the job still ends with `COMPLETED`. The job carries no per-item result. Read each object afterwards. Get a device or Get a point answers `404` when the object is gone. ## What a delete removes KODE OS removes the dependents with the object, so nothing points at an object that no longer exists. | Deleting | Also removes | | - | - | | A device | Every point of the device. Every copy of those points on other devices, and every copy that sits on the device. Every device reference and space reference that other devices hold to it. | | A device, effect on counts | The point count of each device that held a removed copy, and the device count of the building and of the space the device was located in. | | A point | Every copy of the point on other devices. The device that holds the point is not deleted. | | A copy | Only the copy. The source point and the other copies stay. | | A virtual device | The copies on it. To keep points that you attached from pseudo devices, detach them first. | If a device came from a connector discovery, a later discovery offers the device and its deleted points again as new. Other KODE OS features can use a device or point, for example schedules or graphics. This guide lists what the API exposes. Check those features after a delete. # Write to points Source: https://docs.kodelabs.com/products/kode-api/guides/write-to-points Discover the fields a point accepts, then send single, batch, or mass point writes through the KODE API. Point writes change values on building equipment, such as setpoints and overrides. Each point defines the fields it accepts, so you read those fields first and then build the write request from them. Each linked endpoint can switch the sample between cURL, JavaScript, Python, and PowerShell, or send the request for you. > [!WARNING] > > Point writes can command live equipment. Test with a non-critical point, and confirm that your service account has write permission only where it needs it. ## Before you begin You need: * An access token. See the [quickstart](/products/kode-api/quickstart). * The `buildingId`, `datasourceId`, `deviceId`, and `pointId` of a writable point. Points with `writable` set to `true` in [List building points](/products/kode-api/api-reference/points/list-building-points) accept writes. ## Write to a point **1. Get the write fields** Call [List point write fields](/products/kode-api/api-reference/points/list-point-write-fields). Each item in the response is a field you can send. ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/integrations/datasources/${DATASOURCE_ID}/devices/${DEVICE_ID}/points/${POINT_ID}/fields" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` For each field, read: * `identifier`: The value to send as `id`. * `options`: The allowed values. Send the option `_id`. * `metadata.required`: `MANDATORY`, `OPTIONAL`, or `CONDITIONAL`. * `metadata.filter`: For conditional fields, the values of other fields that make this field apply. **2. Build the actions array** Add one entry per field. For example, a typical override needs `priority`, `duration`, and `value`. The `value` and `duration` fields apply only when `priority` is `override`. ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "actions": [ { "id": "priority", "value": "override" }, { "id": "duration", "value": "3600000" }, { "id": "value", "value": 72 } ], "notes": "Raised setpoint for after-hours event" } ``` Duration options are in milliseconds. `-1` means permanent. **3. Send the write** Post the body to [Write to a point](/products/kode-api/api-reference/points/write-to-a-point): ```bash theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --request POST \ "https://api.kodelabs.com/kodeos/api/v1/buildings/${BUILDING_ID}/integrations/datasources/${DATASOURCE_ID}/devices/${DEVICE_ID}/points/${POINT_ID}/write" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" \ --header "Content-Type: application/json" \ --data @write.json ``` The response returns the point priority array, so you can confirm the new value at the level you wrote. **4. Release the override** When the override is no longer needed, send a write with `priority` set to `release`. The equipment then returns to its normal control logic. ## Write to many points To change several points on the same data source, use [Write to points in a batch](/products/kode-api/api-reference/points/write-to-points-in-a-batch). Each item contains the point `id` and its own `actions` array. The response reports `successCount` and `failureCount`. Check `failureCount` before you treat the batch as complete, and do not retry the whole batch blindly. ### Write across devices and buildings To write to points on many devices, or in many buildings, use the mass write operations. You describe the points with a query and check the plan before you write. **1. Discover the groups** Send a `query` with `buildingIds` and any filters to [Discover mass write point groups](/products/kode-api/api-reference/mass-write/discover-mass-write-point-groups). Each group has a `groupKey` and the fields a write to it can carry. **2. Validate the plan** Build `writes` so that every group is in exactly one write. Send the plan to [Validate or apply a mass write](/products/kode-api/api-reference/mass-write/validate-or-apply-a-mass-write) with `validateOnly` set to `true`. Fix the issues in the report, then note the `etag`. **3. Start the write** Send the same plan without `validateOnly`, with a `requestId` and the `etag`. Keep the last segment of `operation.name` as the `operationId`. **4. Follow the operation** Poll [Get a mass write operation](/products/kode-api/api-reference/mass-write/get-a-mass-write-operation) every `metadata.pollAfterSeconds` until `done` is `true`. Reading the operation is what finishes it. Then call [List mass write results](/products/kode-api/api-reference/mass-write/list-mass-write-results) for the outcome of each point. To send failed points again, call [Retry a mass write operation](/products/kode-api/api-reference/mass-write/retry-a-mass-write-operation). # What is the KODE API? Source: https://docs.kodelabs.com/products/kode-api/index Use the KODE API to build services and integrations with KODE OS building and operations data. The KODE API is the programmatic interface to KODE OS. Use it to build integrations, automate operations, and work with building data at scale. KODE teams use the API across internal services and delivery workflows. The same versioned interface supports customer and partner integrations. > [card] [Send your first request](/products/kode-api/quickstart) > > Get a token and list your buildings in about five minutes. > [card] [Browse the API reference](/products/kode-api/api-reference/introduction) > > Explore every endpoint and try requests in the browser. > [card] [Fork in Postman](https://elements.getpostman.com/view/fork?collection=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c\&documenterCollectionId=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c-2sAYkEqfGB\&referrer=https%3A%2F%2Fdocumenter.getpostman.com%2Fview%2F37847641%2F2sAYkEqfGB\&versionTag=latest\&source=documenter) > > Copy the KODE API collection into your Postman workspace, then run the requests there. ## What you can build * **Data ingestion**: Create devices and points, then send current or historical values from your system. * **Building data export**: Read buildings, devices, points, and timeseries into analytics or reporting tools. * **Equipment control**: Write to writable points, such as setpoints and overrides. * **Maintenance workflows**: Create, update, and sync AssetOps work orders with external systems. ## How the API works The KODE API uses resource-oriented HTTPS endpoints with JSON bodies. Most resources sit under a building: ```text theme={"theme":{"light":"github-light","dark":"github-dark"}} https://api.kodelabs.com/kodeos/api/v1/buildings/{buildingId}/... ``` Every request needs a Bearer access token. Your service gets the token by signing a client assertion with the private key issued for your client ID. See [Authentication](/products/kode-api/authentication). Service accounts use scoped permissions by building and operation. The API returns only the resources assigned to your service account. ## Find your way around | Section | Use it to | | - | - | | Get started | Set up credentials and learn conventions shared by every endpoint. | | Guides | Follow end-to-end workflows, such as ingesting device data or writing to points. | | API reference | Look up endpoint parameters and schemas, and send test requests. | ## API lifecycle The `/api/v1/` path identifies the current major version. KODE can add backward-compatible fields and endpoints within this version, so ignore response fields your integration does not recognize. # Quickstart Source: https://docs.kodelabs.com/products/kode-api/quickstart Authenticate with the KODE API and list the buildings your service can access. Get an access token and list the buildings your service can access. This takes about five minutes and confirms that your credentials and permissions work. ## Before you begin You need: * The client ID supplied with your KODE project delivery. * The private key registered for that client ID. * `curl` and `jq`, Node.js 18 or later, Python 3, or PowerShell 7. > [!WARNING] > > Never commit a private key, client assertion, or access token to source control. Store secrets in an approved secrets manager. ## Send your first request Use the language menu on a sample to switch it. The other samples on this page follow that choice. **1. Create a client assertion** Sign a JWT client assertion with your private key, following [RFC 7523](https://datatracker.ietf.org/doc/html/rfc7523). Then store it in an environment variable: ```bash macOS and Linux theme={"theme":{"light":"github-light","dark":"github-dark"}} export KODE_CLIENT_ASSERTION="" ``` ```powershell PowerShell theme={"theme":{"light":"github-light","dark":"github-dark"}} $env:KODE_CLIENT_ASSERTION = "" ``` See [Authentication](/products/kode-api/authentication) for the full token flow. **2. Request an access token** Exchange the assertion for a short-lived access token: ```bash cURL theme={"theme":{"light":"github-light","dark":"github-dark"}} export KODE_ACCESS_TOKEN=$(curl --fail-with-body --silent \ --request POST "https://api.kodelabs.com/oauth2/v1/token" \ --data-urlencode "grant_type=client_credentials" \ --data-urlencode "scope=bms" \ --data-urlencode "client_assertion_type=urn:ietf:params:oauth:client-assertion-type:jwt-bearer" \ --data-urlencode "client_assertion=${KODE_CLIENT_ASSERTION}" \ | jq -r '.access_token') ``` ```powershell PowerShell theme={"theme":{"light":"github-light","dark":"github-dark"}} $body = @{ grant_type = "client_credentials" scope = "bms" client_assertion_type = "urn:ietf:params:oauth:client-assertion-type:jwt-bearer" client_assertion = $env:KODE_CLIENT_ASSERTION } $token = Invoke-RestMethod -Method Post -Uri "https://api.kodelabs.com/oauth2/v1/token" -Body $body $env:KODE_ACCESS_TOKEN = $token.access_token ``` ```javascript JavaScript theme={"theme":{"light":"github-light","dark":"github-dark"}} const body = new URLSearchParams({ grant_type: "client_credentials", scope: "bms", client_assertion_type: "urn:ietf:params:oauth:client-assertion-type:jwt-bearer", client_assertion: process.env.KODE_CLIENT_ASSERTION, }); const response = await fetch("https://api.kodelabs.com/oauth2/v1/token", { method: "POST", headers: { "Content-Type": "application/x-www-form-urlencoded" }, body, }); if (!response.ok) throw new Error(`Token request failed: ${response.status}`); const token = await response.json(); console.log(token.access_token); ``` ```python Python theme={"theme":{"light":"github-light","dark":"github-dark"}} import os import requests response = requests.post( "https://api.kodelabs.com/oauth2/v1/token", data={ "grant_type": "client_credentials", "scope": "bms", "client_assertion_type": "urn:ietf:params:oauth:client-assertion-type:jwt-bearer", "client_assertion": os.environ["KODE_CLIENT_ASSERTION"], }, timeout=30, ) response.raise_for_status() print(response.json()["access_token"]) ``` **3. List your buildings** Send the token in the `Authorization` header: ```bash cURL theme={"theme":{"light":"github-light","dark":"github-dark"}} curl --fail-with-body \ "https://api.kodelabs.com/kodeos/api/v1/buildings?page=1&limit=50" \ --header "Authorization: Bearer ${KODE_ACCESS_TOKEN}" ``` ```javascript JavaScript theme={"theme":{"light":"github-light","dark":"github-dark"}} const response = await fetch( "https://api.kodelabs.com/kodeos/api/v1/buildings?page=1&limit=50", { headers: { Authorization: `Bearer ${process.env.KODE_ACCESS_TOKEN}` } }, ); if (!response.ok) throw new Error(`Request failed: ${response.status}`); console.log(await response.json()); ``` ```python Python theme={"theme":{"light":"github-light","dark":"github-dark"}} import os import requests response = requests.get( "https://api.kodelabs.com/kodeos/api/v1/buildings", params={"page": 1, "limit": 50}, headers={"Authorization": f"Bearer {os.environ['KODE_ACCESS_TOKEN']}"}, timeout=30, ) response.raise_for_status() print(response.json()) ``` ```powershell PowerShell theme={"theme":{"light":"github-light","dark":"github-dark"}} $headers = @{ Authorization = "Bearer $env:KODE_ACCESS_TOKEN" } Invoke-RestMethod -Uri "https://api.kodelabs.com/kodeos/api/v1/buildings?page=1&limit=50" -Headers $headers ``` A successful response returns `200 OK` with a paginated `data` array: ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} { "data": [ { "_id": "67c960faffaa42223163099e", "name": "KODE OS Office", "tz": "America/Detroit" } ], "itemCount": 1, "limit": 50, "page": 1, "pageCount": 1 } ``` ## If something goes wrong | Result | Likely cause | What to do | | - | - | - | | `401` from the token endpoint | Assertion is expired, unsigned, or uses the wrong key. | Create a new assertion with the registered private key. | | `401` from the API | Access token is missing or expired. | Request a new access token. | | Empty `data` array | Service account has no building assignments. | Ask your KODE project team to assign buildings. | ## Next steps > [card] [Try it in the playground](/products/kode-api/api-reference/buildings/list-buildings?playground=open) > > Paste your token and send the buildings request from the browser. > [card] [Ingest device data](/products/kode-api/guides/ingest-device-data) > > Create devices and send point values from your system. > [card] [Fork in Postman](https://elements.getpostman.com/view/fork?collection=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c\&documenterCollectionId=37847641-0db06e08-772a-492b-9a93-f5d18c67b15c-2sAYkEqfGB\&referrer=https%3A%2F%2Fdocumenter.getpostman.com%2Fview%2F37847641%2F2sAYkEqfGB\&versionTag=latest\&source=documenter) > > Copy the KODE API collection into your Postman workspace, then run the requests there. # Accessibility in KODE OS Source: https://docs.kodelabs.com/products/kode-os/accessibility How KODE OS supports keyboard navigation, screen readers, and visual accessibility across Cloud BMS and every KODE OS product. KODE OS supports people with visual, auditory, motor, and cognitive disabilities. Accessibility is built into every KODE OS product, including Cloud BMS. There is no separate accessibility mode to turn on, and no setup is required. ## Accessibility coverage Every KODE OS product meets the KODE Labs accessibility standard: * [Cloud BMS](/products/kode-os/get-started/introduction) * [Building BI](/products/building-bi/overview) * [Graphics](/products/kode-os/graphics/graphic-tool) * [FDD](/products/fdd/overview) * [Functional Testing Tool (FTT)](/products/ftt/overview) * [Launchpad](/products/launchpad/get-started/introduction) * Building Data Hub * [EnerG](/products/energ/get-started/introduction) * [AssetOps](/products/assetops/quickstart/overview) Across these products, you can expect screen-reader support, keyboard navigation, strong color contrast, and consistent interface components. Existing layouts, workflows, and functionality work the same way for every user. ## Accessibility in Cloud BMS Cloud BMS uses the same accessible components as the rest of KODE OS. You can navigate and operate the following areas with a keyboard or screen reader: * [Device details](/products/kode-os/devices/devices) and [point commanding](/products/kode-os/points/commanding-points) * [Systems](/products/kode-os/systems) and tenants * [Schedules](/products/kode-os/schedules) and [Optimized Start/Stop](/products/kode-os/oss) * [Graphics](/products/kode-os/graphics/graphic-tool) in view mode * Building dashboards ## Using a keyboard KODE OS supports navigation without a mouse. Common controls include: | Key | Action | | - | - | | Tab | Move to the next interactive element | | Shift + Tab | Move to the previous interactive element | | Enter or Space | Select a button, link, or other control | | Arrow keys | Navigate within menus, tabs, and option lists | | Escape | Close an open menu, dialog, or panel | A visible focus indicator shows which element is selected. ## Using a screen reader KODE OS components work with screen readers through meaningful labels, page structure, control states, and status announcements. For the best experience: 1. Start your screen reader before you open KODE OS. 2. Use your screen reader’s standard commands to move by headings, links, buttons, forms, and tables. 3. Use KODE OS in a current version of a supported browser. > [!NOTE] > > Screen-reader behavior can vary by browser, operating system, and assistive technology. ## Visual accessibility KODE OS interface components provide: * Strong color contrast for text and interface controls * Clear keyboard-focus indicators * Consistent component styling and behavior * Information that does not rely on color alone * Readable text and layouts across the platform You can also use your browser’s built-in zoom controls to enlarge the interface. ## Report an accessibility issue If you encounter an accessibility barrier, contact KODE Labs Support and include: * The KODE OS application and page * What you were trying to do * What occurred * Your browser and operating system * The assistive technology you were using, if applicable * A screenshot or screen recording, when possible This information helps the team investigate and address the issue. ## Next steps > [card] [Accessibility in Building BI](/products/building-bi/reference/accessibility/overview) > > Learn how Building BI dashboards, widgets, and chart data support assistive technology. > [card] [Graphics](/products/kode-os/graphics/graphic-tool) > > Build and view floor plans, system graphics, and device graphics in Cloud BMS. # Areas Source: https://docs.kodelabs.com/products/kode-os/areas Define and manage the spatial zones in your building, including floors, zones, and rooms, with interactive floor plan views. > [!NOTE] > > Areas is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its areas and floor plans. Areas define the physical layout of a building in Cloud BMS. They represent spatial zones such as floors, wings, zones, and rooms, organized in a hierarchical structure from the site level down to individual spaces. Areas are the foundation for floor plan views, spatial filtering, and location-based monitoring. ## Area hierarchy Areas follow a top-down structure: ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR SITE[Site / Building] -- "divided into" --> F1[Floor 1] SITE -- "divided into" --> F2[Floor 2] F1 -- "subdivided into" --> Z1[Zone A] F1 -- "subdivided into" --> Z2[Zone B] Z1 -- "contains" --> R1[Room 101] Z1 -- "contains" --> R2[Room 102] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef peach stroke:#FBB35A,fill:#FFEFDB,color:#8F632D classDef green fill:#B0E4CC,color:#285A48,stroke:#285A48 class SITE sky class F1,F2 peach class Z1,Z2,R1,R2 green ``` * **Site** is the top level, representing the entire building * **Floor** divides the building into vertical levels * **Zone/Room** subdivides floors into specific spaces Devices and data sources are assigned to areas, enabling you to filter dashboards, reports, and floor plans by physical location. ## Access areas Click `Areas` in the left sidebar menu from your building view. Select a floor from the area list on the left to display its floor plan with device overlays and live data. ![Areas module showing Floor 2 selected with layer tabs for Devices, Temperature, Occupancy, and the floor plan with device markers](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-floor-plan-view.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=4321fd5dcecbcea0c8a79bdb6ee928b9) The area view shows the floor list on the left, layer tabs for device categories, and the floor plan with live device markers ### Floor plan navigation The floor plan widget displays devices on a spatial layout. Use the layer tabs (`Devices`, `Temperature`, `Occupancy`, and others) to switch between device categories. Use the following controls to navigate the floor plan: * **Pan** by holding the left mouse button and dragging * **Zoom** using the `+` and `-` buttons in the lower right corner * **Reset view** by clicking the four outward arrows icon * **Smart Markers** toggle to enable or disable smart marker display * **Legend** toggle to show or hide the icon legend with value ranges ![Floor plan view with Smart Markers and Legend toggles enabled, showing the legend panel with Zone Temp value ranges and corresponding icons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-legend.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9054a2b28387c1e1aeb14f75bb6dd296) The Smart Markers and Legend toggles control marker display and the legend panel shows the configured value ranges ### Interact with devices on the floor plan Hover over a device marker on the floor plan to expand its point values. Writable points display an edit icon next to the value. ![Expanded device marker for VAV\_210 showing Zone Temp Setpt and Zone Temp values with edit icons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-device-hover.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=abf27db266f26f459dd549d66539c8e3) Clicking a device marker reveals its point values with edit icons for writable points Click the edit icon next to a writable point to open the command panel. The panel displays the device's variables on the left and the action form on the right. ![Command panel showing device variables on the left and action fields for priority, value, duration, reason, and specific reason on the right](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-command-panel.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=e12b34df84cf77d3bc6352632e69ee9c) The command panel lets you override a point value with a specified priority, duration, and reason * **Priority** -- select the command priority level (for example, `Override`) * **Value** -- set the target value. Use `+` and `-` to adjust. * **Duration** -- specify how long the command remains active. Check `Permanent` for an indefinite override. * **Reason** -- select a predefined reason from the dropdown * **Specific Reason** -- enter a custom reason for the change * Click `Save Changes` to send the command, or `Close` to cancel Click `Activity Log` in the upper right corner of the panel to view the command history for the selected point. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ### Area events Select the active events icon on the floor plan to view fault detection events specific to that area. This filtered view shows only the events related to devices in the selected floor or zone. ### Add a dashboard to an area When you select an area that has no dashboard configured, the view displays a "No Dashboard Added Yet" message with an option to create one. ![Floor 3 area view showing No Dashboard Added Yet message with an Add Dashboard button](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-dashboard-empty.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=aa6cfdb7020043c05cbb4a4f1873399d) An area without a dashboard displays a prompt to add one Click `+ Add Dashboard` to open the creation dialog. ![Add Dashboard dialog with Dashboard Title, Description, and Access Level fields](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-add-dashboard.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=bf67d9a3a496147530a5b38c1ba1f8f3) The Add Dashboard dialog collects a title, description, and access level **Dashboard Title** `Field` Enter a name for the dashboard (for example, `Floor 03`). **Description** `Field` Provide a brief description of the dashboard's purpose. **Access Level** `Field` Select which user roles can view this dashboard. If no role is selected, all roles have access. ## Add a BIM model to an area Cloud BMS supports 3D BIM models on area dashboards. [Add a BIM file](/products/kode-os/settings#add-a-bim-file) in building settings first, then add a **BIM Model** widget to the area and place device points on the 3D floor plan. ### Add the BIM Model widget **1. Open the area dashboard menu** Open `Areas` and select an area (for example, **Floor 06**). On the area dashboard, select the three-dot menu in the upper-right corner and choose `Add Widgets`. ![Area dashboard three-dot menu showing Add Dashboards, Arrange Dashboards, Add Widgets, Arrange Widgets, and Delete Dashboard](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-dashboard-menu.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=fe0e12af2eb123acb25b640cc12c9290) The dashboard menu includes Add Widgets for adding a BIM Model or other widget types **2. Select BIM Model** In the **Add Widget** dialog, select `BIM Model` and click `Add`. ![Add Widget dialog showing widget types including Network Status, Device Summary, System Summary, Weather Forecast, Events, Raw Data, BIM Model selected, Picture, and Graphic](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-add-widget-bim.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=bbb27ffce21d2e361f2d65602f5d766e) The Add Widget dialog lists BIM Model among available widget types **3. Enter card details** The **BIM Model Configurator** opens on the **Card Details** step. Enter a **Card Name**, select the **3D Model File** you uploaded in building settings, and optionally add a **Description**. Click `Next`. ![BIM Model Configurator Card Details step with Card Name Floor 03, 3D Model File dropdown showing an fbx file selected, and Description field](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-bim-configurator-card-details.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=693c6d1d3f065ae62bb55cc73db9b65b) Card Details step where you name the widget and select the uploaded 3D model file **Card Name** `Field` *required* Name for the BIM widget as it appears on the area dashboard. **3D Model File** `Field` *required* The BIM file uploaded on the building **Files** tab in Settings. **Description** `Field` Optional text describing the 3D floor plan widget. **4. Place device points on the model** On the **Model labels** step, use the **Devices** or **Floors** tab in the left sidebar to find items. Drag and drop device points onto the 3D floor plan. Use the viewer toolbar to orbit, pan, zoom, and inspect the model. Click `Save` when placement is complete. ![BIM Model Configurator Model labels step showing Devices tab with searchable device list and a 3D building floor model with navigation cube and viewer toolbar](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-bim-configurator-model-labels.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=08354c39ed8d92840a0fa4ea4f72fbe1) Model labels step with a device list and interactive 3D viewer for placing points on the floor plan ### View the 3D floor plan After you save the widget, the area dashboard shows an **Overview** tab and a **3D Floor Plan** tab. Open **3D Floor Plan** to view the BIM model with placed device markers and layer controls. The BIM widget displays the configured card name, the 3D model, and device point markers you placed during setup. ![Floor 06 area dashboard with 3D Floor Plan tab showing Floor 6 BIM widget with 3D model and orange device point marker on the floor plan](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-bim-widget-view.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=c05310b0c8e5e2c3efeca2e1a7389c50) BIM Model widget on the area dashboard showing the 3D floor plan and device markers Use the widget three-dot menu to edit, share, copy, or delete the BIM widget, similar to other area dashboard widgets. ### Add a graphic widget to an area You can add a graphic widget to an area dashboard to embed a floor plan graphic directly on the area page. **1. Open the dashboard menu** Click the three-dot menu in the upper right corner of the area view and select `Add Widgets`. ![Dashboard menu showing Add Dashboards, Arrange Dashboards, Add Widgets, Arrange Widgets, and Delete Dashboard options](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-dashboard-menu.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=fe0e12af2eb123acb25b640cc12c9290) The dashboard menu provides options to add and arrange dashboards and widgets **2. Select the Graphic widget** In the Add Widget dialog, select `Graphic` and click `Add`. ![Add Widget dialog showing available widget types with the Graphic widget selected](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-add-widget.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=62f202986c0316443722a27cbb96196d) The Add Widget dialog offers widget types including Events, Raw Data, BIM Model, Picture, and Graphic **3. Choose or create a graphic** Select an existing graphic from the list, or click `Create new graphic` to build one from scratch. Click `Next` to add it to the dashboard. ![Create or Select a Graphic dialog showing a searchable list of existing graphics with an option to create a new graphic](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-select-graphic.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=8ebfd76b08fab24955a83d80eb85738c) Select an existing graphic or create a new one to embed in the area dashboard Once the graphic is added, the area dashboard displays the floor plan with device markers and layer tabs. Click the three-dot menu on the dashboard widget to access additional options. ![Area dashboard for Floor 2 showing a floor plan graphic with Devices, Temperature, and Occupancy layer tabs, and a three-dot menu with Edit, Share, Copy to, and Delete options](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-dashboard-menu-options.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=32a9dce68b93a30bddf2f2a0686f2e6c) The area dashboard shows a floor plan graphic with layer tabs and a menu for editing, sharing, copying, or deleting the widget * **Edit** -- open the graphic in the [Graphic Tool](/products/kode-os/graphics/graphic-tool) to modify markers, layers, or overlays * **Share** -- generate a shareable link to the dashboard * **Copy to** -- copy the widget to another area's dashboard * **Delete** -- remove the widget from the dashboard ## Manage areas Click `Areas` in the left sidebar to view the areas list. The list shows each area's name and device count. ![Areas list showing Floor 2 with 12 devices, Floor 3 with 49 devices, Floor 4 and test with no devices, plus Add Area button and search](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-list.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=dea2131cae95d2075129f6490b3c26f0) The Areas list displays all areas with their device counts, search, and batch update options ### Add areas Click `+ Add Area` to open the Add Areas dialog. Enter a name for each area. Click `+ Add Row` to add additional areas, or click `Add Multiple Rows` to add several at once. ![Add Areas dialog with two name input rows, Add Multiple Rows and Add Row buttons, and an Add Areas button](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-add-dialog.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=86203a86ee751b3daa5d6ba4e12b0bbb) The Add Areas dialog lets you create one or more areas by entering names in each row ### Edit and delete individual areas Hover over an area row and click the three-dot menu to access `Edit` or `Delete` for that area. ![Areas list with three-dot menu expanded on Floor 2 showing Edit and Delete options](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-row-menu.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=6d970c10a107b7ec4940568352e0d929) The row menu provides Edit and Delete options for individual areas ### Delete areas in bulk Click `Batch Update` to enter selection mode. Select the areas you want to remove, then click `Delete Area(s)` in the lower right corner. ![Areas list in Batch Update mode with three areas selected and a Delete Area(s) button in the lower right](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-batch-delete.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=9fc799c8d07e2206d1ef0b82786a3e66) Batch Update mode lets you select multiple areas for bulk deletion > [!WARNING] > > Deleting an area removes the spatial assignment for all devices in that area. Devices are not deleted, but they lose their area association. Reassign them to a new area after deletion. ### Reorder areas Click the three-dot menu next to `+ Add Area` and select `Reorder Areas`. Drag and drop the areas into the desired order, then click `Save`. ![Three-dot menu showing the Reorder Areas option](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-reorder.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=7754217a696cdbb687dc62b92014075e) The Reorder Areas option is accessible from the three-dot menu next to the Add Area button ## Assign devices to areas Devices are assigned to areas during initial discovery or through the [device details](/products/kode-os/devices/devices) page. To reassign a device to a different area: * Open the device's details page and edit the `Area` field * Use the [device batch update](/products/kode-os/devices/device-batch-update) feature to reassign multiple devices at once ## Next steps > [card] [Building settings](/products/kode-os/settings#add-a-bim-file) > > Upload BIM model files on the building Files tab before adding them to areas. > [card] [Floor plan graphics](/products/kode-os/graphics/floor-plans) > > Create 2D floor plan graphics in the Graphic Tool and embed them on area dashboards. > [card] [Systems](/products/kode-os/systems) > > View devices organized by functional system rather than physical location. # AssetOps and work orders in Cloud BMS Source: https://docs.kodelabs.com/products/kode-os/assetops/work-orders Access AssetOps and manage building work orders from the Cloud BMS building sidebar when AssetOps is enabled When **AssetOps** is enabled for a client organization, users with access see **AssetOps** and **Work orders** in the Cloud BMS building sidebar. You can open the full AssetOps building experience or work directly in **Work orders** without leaving Cloud BMS. Work orders in Cloud BMS use the same building-level AssetOps capabilities as the standalone AssetOps app: list and filter work, create orders, open details, bulk edit, and export data. For portfolio-wide views and configuration, see [AssetOps](/products/assetops/quickstart/overview). > [!NOTE] > > Enable AssetOps per building in [Launchpad](/products/launchpad/channel-partners/product-enablement) before the modules appear in Cloud BMS. This is separate from [FDD work orders](/products/fdd/work-orders), which generate CMMS tickets from fault events. *** ## Building sidebar modules At the building level, the left sidebar includes module links alongside systems, devices, and points. | Module | Purpose | | - | - | | **AssetOps** | Opens the AssetOps building application in a new context. Use it for assets, schedules, asset discovery, teams, and other building maintenance modules. | | **Work orders** | Opens the building work orders list inside Cloud BMS. Use it for day-to-day work order triage and updates. | Both modules require AssetOps to be enabled for the building. If you do not see them, confirm product enablement with your administrator. *** ## Work order list Select **Work orders** in the building sidebar to open the list for that site. ![Cloud BMS Work Orders page with building sidebar showing AssetOps and Work Orders, status summary cards, search, Focus Mode, Filters, and work order table](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-orders-list.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=d1353c16fc64cbc5f56f9202f003e7f0) Cloud BMS building sidebar with AssetOps and Work orders modules and the work orders list ### Status summary cards Select a card to filter the table by status. | Status | Description | | - | - | | **Open** | Created but not yet started | | **In progress** | Currently being worked on | | **On hold** | Paused | | **For review** | Completed work awaiting review | | **Completed** | Finished work | | **Failed** | Work that did not complete successfully | | **Cancelled** | Cancelled work orders | | **Overdue** | Past due date and not completed | ### List actions * **Search** — Filter the table by text across visible fields * **Focus mode** — Show work orders that need immediate attention (SLA breached, warnings, high priority). See [Focus mode](/products/assetops/work-orders/work-orders-overview#focus-mode). * **Filters** — Open the filter panel. See [Custom filters](#custom-filters). * **+ Create work order** — Start a new work order. See [Create a work order](#create-a-work-order). * **Edit** and **Delete** — Appear when you select one or more rows * Vertical ellipsis menu — Additional actions such as **Export** Select a **Title** link or the external-link icon beside the title to open the [work order detail page](/products/assetops/work-orders/work-orders-overview#work-order-detail-page). The detail experience matches [Building work orders](/products/assetops/work-orders/work-orders-overview) in AssetOps. ### Table columns Use the column control and horizontal scroll to show all fields. | Column | Description | | - | - | | **Title** | Work order name as a link, with work order ID below (for example, `WO-10205`) | | **Status** | Current lifecycle status | | **Work type** | Program type (for example, corrective maintenance, preventive maintenance, inspection) | | **Asset** | Asset the work applies to | | **Located in** | Building area or location hierarchy | | **Priority** | Priority level from [Priority & SLA](/products/assetops/portfolio/priority-sla) | | **Schedule** | Source schedule name and ID. Select the link to open the schedule on the [building schedules](/products/assetops/schedules/schedules-overview#schedule-detail-page) page. | | **Tasks** | Task count or summary | | **Deficiency** | Linked deficiency or inspection finding when applicable | | **SLA status** | SLA state (for example, on track, warning, breached) | | **Created date** | Date the work order was created | | **Start date & time** | Scheduled or actual start | | **Due date & time** | Target completion date and time | | **Logged time** | Total time logged on the detail page | | **Assignee** | User assigned to the work | | **Team assigned** | Team assigned to the work | | **Category & issue** | Category and issue type | | **Follow up** | Indicates whether follow-up work is required or pending | ### Export Open the vertical ellipsis menu in the list header and select **Export** to download work order data. *** ## Custom filters Select **Filters** to narrow the list. ![Work Orders filters sidebar with Created Date, Start Date and Time, Due Date and Time, Work Type, Inspection Type, and Priority fields](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-orders-filters.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=89be545819d08e17d541e99c06f95c25) Work order filters for dates, work type, inspection type, and priority | Filter | Description | | - | - | | **Created date** | Date range when work orders were created | | **Start date & time** | Scheduled or actual start range | | **Due date & time** | Target completion range | | **Work type** | Preventive maintenance, corrective maintenance, inspection, or other types | | **Inspection type** | Inspection category for inspection work orders | | **Priority** | Priority level | Additional filters such as category, assignee, and asset are documented on [Building work orders](/products/assetops/work-orders/work-orders-overview#custom-filters). Select **Clear all** to reset filters. *** ## Bulk edit work orders Update multiple work orders from the list. ![Work Orders list with rows selected and Edit and Delete buttons enabled in the toolbar](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-orders-bulk-select.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=a745acc77cfb402118caaf90bd4e0d44) Select rows to enable Edit and Delete in the toolbar **1. Select work orders** Use row checkboxes or the header checkbox to select work orders. **2. Open bulk edit** Select **Edit** in the toolbar. **3. Choose fields and save** Enable the checkbox for each field you want to change, enter values, then select **Save**. Changes apply to every selected work order. ![Bulk Edit modal with warning banner and checkboxes for Due Date, Assignee, Team Assigned, and Status with Enter Status Note field](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-orders-bulk-edit.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=d8b0f89b2030e915a4b3b462a34c8757) Bulk Edit modal updates due date, assignee, team, and status for selected work orders > [!WARNING] > > Any changes you save apply to all selected work orders. Bulk **Delete** permanently removes selected records and cannot be undone. **Due date** `Date` Target due date and time for selected work orders. **Assignee** `Dropdown` User assigned to the selected work orders. **Team assigned** `Dropdown` Team assigned to the selected work orders. **Status** `Dropdown` Lifecycle status for selected work orders. **Enter status note** `Field` Optional note recorded with a status change. *** ## Create a work order Select **+ Create work order** to add corrective or other generic work for the current building. ![Create Work Order form with Title, Work Type, Asset, Located In, Category, Issue Type, Priority, Description, and Attachments upload](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-orders-create.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=4bcb652154c395a138b0006a17e18b17) Create Work Order form in Cloud BMS for the open building The form matches the [building create flow](/products/assetops/work-orders/work-orders-overview#create-a-work-order). Required fields include **Title**, **Work type**, **Category**, **Issue type**, and **Priority**. [Routing and dispatch](/products/assetops/resources/routing-dispatch) may prefill **Assign team** and **Assignee** when rules exist. Select **Save** to create the work order, then open it from the list to manage tasks, logged time, and follow-ups on the work order detail page. *** ## Work order detail page Select a **Title** link from the list to open the detail page in building context. The header shows the work order name, ID badge, comment icon, and a vertical ellipsis menu for actions such as status history and delete. ![Work order Details tab in Cloud BMS showing Completed status, Schedule and Log link, Asset link, and Tasks with 6 of 6 completed](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-assetops-work-order-details.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=211da208b970b4ae0fe0d238a9feb991) Work order detail page with Details tab, schedule log link, asset link, and task checklist progress The **Details** tab includes **General information** (status, dates, work type, assignee, schedule log, and asset links) and a **Tasks** checklist with **Update multiple** for bulk task updates. **Attachments** and **Follow-ups** tabs match the [Building work orders](/products/assetops/work-orders/work-orders-overview#work-order-detail-page) reference. *** ## Open AssetOps from Cloud BMS Select **AssetOps** in the building sidebar to open the AssetOps building application. From there you can manage [assets](/products/assetops/assets/assets), [schedules](/products/assetops/schedules/schedules-overview), [asset discovery](/products/assetops/assets/asset-discovery), and other modules documented in the AssetOps product guide. Use **Work orders** in Cloud BMS when you only need the work order list and detail flows without switching applications. *** ## Related documentation > [card] [Building work orders](/products/assetops/work-orders/work-orders-overview) > > Full reference for list actions, detail tabs, tasks, logged time, and follow-ups. > [card] [AssetOps overview](/products/assetops/quickstart/overview) > > Portfolio and building workflows for maintenance operations. > [card] [Enable AssetOps](/products/launchpad/channel-partners/product-enablement) > > Turn on AssetOps per client and building in Launchpad. > [card] [FDD work orders](/products/fdd/work-orders) > > CMMS work orders generated from FDD fault events, not AssetOps maintenance work orders. # Data sources Source: https://docs.kodelabs.com/products/kode-os/data-sources Connect external building systems to Cloud BMS and monitor the health of your data integrations. > [!NOTE] > > Data sources is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its data sources. Data sources are the connection points between Cloud BMS and external building systems. Each data source represents a configured integration with a building automation system (BAS), meter, IoT platform, access control system, or other external service. Data sources collect device and point data from these systems into Cloud BMS for monitoring, control, and analytics. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR EXT["External System (BAS, Meter, IoT)"] DS[Data Source / Connector] DEV[Devices] PTS[Points] EXT -- "protocol (BACnet, REST, MQTT)" --> DS DS -- "discovers" --> DEV DEV -- "contains" --> PTS classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef peach stroke:#FBB35A,fill:#FFEFDB,color:#8F632D classDef rose stroke:#FF5978,fill:#FFDFE5,color:#8E2236 class EXT sky class DS peach class DEV,PTS rose ``` ## Navigate to data sources **1. Select your site** Click `Sites` in the left navigation bar and select the building you want to manage. **2. Open data sources** From the left sidebar menu, click `Data Sources`. The data sources list displays all configured connections for the selected site. ![Data sources list with columns for name, discovery support, URL, data source type, area, and room](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-list.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=8542bccf7be507d278f8d3974bbb43b1) The data sources list shows each connection's name, discovery support, data source type, area, and room ## Add a new data source You add data sources by selecting from the API catalog, which organizes available integrations by system type. Cloud BMS supports 200+ integrations across BACnet, Modbus, REST API, MQTT, and other protocols. **1. Open the API catalog** On the `Data Sources` page, click `API Catalog` in the left panel. The catalog displays available integrations organized by category (Access Control, Asset, BAS, Meter, and others). Use the search bar to find a specific integration. ![API catalog page showing integrations grouped by category with a search bar](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-api-catalog.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=6f7e276ea8df40a4f310680475a033cf) The API catalog organizes integrations by system type **2. Select an integration** Click the integration you want to configure. The integration detail page displays supported entities, data collection schedules, and available fields. **3. Enter authentication details** Click `+Add Data Source` in the upper right corner. A three-step wizard opens starting with the `Authentication` step. Fill in the connection fields specific to the selected integration type. ![Add Data Source dialog at step 1 showing fields for name, area, room, URL, username, and password](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-add-authentication.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=ce2bcb245852287bf9f7d10acd045444) Step 1 of the wizard collects authentication details for the external system **Common authentication fields** | Field | Description | | - | - | | `Name` | A descriptive name for this data source (for example, `Lobby BACnet Controller`) | | `Area` | The building area this data source serves | | `Room` | The specific room associated with this data source | | `URL` | The endpoint address for the external system | | `Username` | Authentication credential for the external system | | `Password` | Authentication credential for the external system | For Niagara integrations, install the driver described in [Tridium Niagara](/products/integrations/controllers/niagara) on the station before you add the connector. Optional scope fields can then narrow discovery: | Field | Description | | - | - | | `Folder` | Limits discovery to devices inside a specific folder in the Niagara station | | `Devices Root Slot` | Niagara slot path where Cloud BMS begins searching for devices (for example, `slot:/Drivers/...`) | Use these fields when a station has a large device tree or when multiple buildings share one Supervisor. Narrowing the scope reduces discovery time and makes results easier to review. Click `Test Connection` to verify your credentials before proceeding. If authentication succeeds, click `Next`. > [!TIP] > > For APIs that support dynamic ID discovery, Cloud BMS retrieves available Site IDs and Building IDs directly from the API after you verify your credentials. Instead of manually requesting these identifiers from the vendor or client, you can select them from a dynamically loaded list. This capability depends on the external API. Not all integrations support it. **4. Configure data streams** In the `Configuration` step, select which data streams to collect. Toggle individual streams on or off, and set the collection frequency for each. ![Configuration step showing Timeseries and Alarm data streams with collection frequency settings](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-add-configuration.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=410e7549f4fc1e3895f90a041529811b) Step 2 lets you enable data streams and set collection intervals Each data stream displays an allowed frequency range. Set the `Value` and `Interval` (seconds or minutes) within that range. Click `Next` when finished. **5. Review and submit** The `Review` step displays a summary of your selected data streams and their collection frequencies. Verify the configuration and click `Submit` to create the data source. ![Review step showing Timeseries enabled at every 30 seconds and Alarm enabled at every 5 minutes](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-add-review.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=21b1f68c9ae737d58067fea172e47d5a) Step 3 shows a summary of enabled data streams and collection frequencies ## Subsystem alarm ingestion Connectors can ingest native **alarms** from external building systems into the KODE alarm engine. Ingested alarms appear on the [FDD Events](/products/fdd/events) page alongside routine-generated faults. Use this when operators need a single console for BMS alarms instead of switching between KODE and the subsystem interface. Niagara is the first supported integration. Additional subsystems will follow the same normalized alarm framework. ### Enable alarm collection When you add or edit a data source, enable the **Alarm** data stream in the **Configuration** step. Set the collection **Value** and **Interval** within the allowed range, then complete the wizard. **1. Open the connector configuration** Add a new data source from the [API catalog](#add-a-new-data-source), or open an existing connector and select **Edit** from the three-dot menu. **2. Enable the Alarm stream** In the **Configuration** step, toggle **Alarm** on and set the collection frequency. ![Configuration step showing Timeseries and Alarm data streams with collection frequency settings](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-add-configuration.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=410e7549f4fc1e3895f90a041529811b) Step 2 lets you enable data streams and set collection intervals **3. Submit and verify** Complete the wizard, then open the connector **Analytics** tab to confirm alarm collection activity. Alarms enabled in the source system should appear on [FDD Events](/products/fdd/events). Each building requires its own connector configuration. Alarm enablement and disablement remain in the source system. KODE ingests alarms that are active in the source. ### Bi-directional acknowledgment When ack writeback is supported for the connector, acknowledging an alarm in KODE updates the source system. Acknowledgments made in the source also sync to KODE. **Ack writeback** prevents unacknowledged alarms from accumulating in the BMS queue, which can exhaust subsystem resources. Operators can acknowledge from KODE without opening the Niagara or BMS console. ### V1 scope | Included | Not included in V1 | | - | - | | Full visualization of enabled source alarms | Selective ingestion filters (priority, category, name, domain) | | Bi-directional ack sync (Niagara) | [Notification policy](/products/fdd/notification-policies) routing for subsystem alarms | | Normalized alarm fields (name, description, category, priority, status, device, timestamps) | Inline UI confirmation of writeback success or failure | Alarm filtering and notification routing for subsystem alarms are planned for future releases. > [!NOTE] > > Subsystem alarm ingestion does not replace FDD routines. Both can run in parallel while operators transition to KODE as the primary alarm console. ## Connector view After you add a data source, the connector view provides real-time visibility and control over the integration. Select any data source from the list to open its connector view. ![Connector view showing overview cards for devices, points, and schedules with a data stream collection chart](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-connector-analytics.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=c5b24b07a1536cf128216d87de32ba07) The connector view displays collection metrics, discovered entities, and data stream activity The upper-right corner of the connector view provides these controls: * **Live Updates** enables real-time monitoring of API requests * **Test Connection** verifies the data source is reachable and credentials are valid * **Details** displays the connection configuration * **Activity** opens a panel showing a log of recent actions and credential changes > [!WARNING] > > The status badge in the upper-left of the connector view reflects successful data collection. It is not the same as connectivity. A connector can pass `Test Connection` and still show collection problems. ![Activity panel showing a connector update entry with credential and URL changes](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-activity-panel.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=e0874d7c7accd3bb69a43c299e6f9064) The Activity panel shows a timestamped log of connector updates The three-dot menu in the connector view provides additional options: ![Connector three-dot menu with options for Import from Sheet, Refresh Cache, Edit, Disable, and Delete](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-connector-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=4500d3a9ce2077ceb06ebb8c49011b67) * **Import from Sheet** imports devices and points from a spreadsheet before or after connectivity is established (see [Import devices and points from a sheet](#import-devices-and-points-from-a-sheet)) * **Refresh Cache** reloads cached data from the external system * **Edit** opens the data source configuration for modification * **Disable** temporarily pauses data collection without deleting the data source * **Delete** permanently removes the data source ### Analytics tab The `Analytics` tab displays data collection metrics and discovery statistics. Use the **Overview** section to see: * **Devices** discovered, with a health status badge and modeled-versus-total count * **Points** discovered, with modeled-versus-total breakdown * **Schedules** discovered from the external system Use the **Data Stream** section to monitor collection activity: * **Collection Activity** shows total items collected in the filtered period and all time, with timestamps for the next collection, last collection, and collecting-since date * **Data Stream Graph** displays collection activity over time with green bars for successful collections and red bars for failures The data stream chart supports two views. Use the `Records` and `Collects` tabs to switch between them. * **Records** shows how many data records were gathered from the API during each time period. Use this to verify that the external system is sending data as expected. * **Collects** shows how many times Cloud BMS attempted to collect data. Use this to verify that collection is running on schedule. ![Data Stream section showing the Collects tab with a bar chart of collection activity over the last seven days](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-data-stream-collects.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=5de6186aa206f5febc335b1063409bf1) The Collects tab shows collection frequency over time > [!TIP] > > If the `Collects` chart shows consistent activity but `Records` shows zero, the collection is running correctly but the external system has no new data to send. If `Collects` drops below the expected count (for example, fewer than 12 per hour for a five-minute collection frequency), investigate whether the connection or the collection process is experiencing issues. For Niagara timeseries streams, Cloud BMS polls point values every 30 seconds and stores a new record when the value changes. If the value stays unchanged, Cloud BMS records it again after one hour to confirm continuity. Use **Pause Collection** on an individual data stream to stop collection without disabling the full connector. Resume collection from the same controls when you are ready. Use the `Export` button to download collection data, and the date range selector to filter the chart to specific time periods. > [!NOTE] > > Click `Live Updates` to enable real-time monitoring of API requests. Every time Cloud BMS makes a request to the external system, the screen refreshes with the latest data. This is useful for debugging or real-time monitoring of a specific data source. ### Modify data collection frequency **1. Open the edit dialog** On the `Analytics` tab, go to the `Data Stream` section and click `Edit Configurations`. The `Edit Data Source` dialog opens with data stream settings. **2. Set the new frequency** Toggle individual data streams on or off using the `Select All` toggle or individual stream toggles. For each enabled stream, set the `Value` and `Interval` within the allowed range. ![Edit Data Source dialog showing Timeseries and Alarm data streams with collection frequency fields and allowed ranges](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-edit-configuration.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=577dcb0b76e94097386ff44b43ae4ddd) The Edit Data Source dialog lets you adjust collection frequency for each data stream **3. Review and apply** Click `Next` to review your changes, then click `Submit` to apply the updated configuration. ### Health tab The `Health` tab provides a real-time overview of the connector's operational status. > [!TIP] > > If a data source is offline, open the connector `Health` tab and note the error category. Follow the suggested actions in the [error category reference](#error-category-reference). ![Health tab showing 4 failures, 90.38 percent uptime with an uptime graph and error logs table](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-health-tab.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=48d64fcfa5c20001820e522225ae9a11) The Health tab shows uptime metrics and error logs for the data source Use the **Uptime Activity** section to monitor: * **Failures** count in the selected date range * **Uptime** percentage over the selected period * **Uptime Graph** with color-coded bars showing periods of uptime (green) and downtime (red) Use the `Filter by category` dropdown and the date range selector to narrow results to specific error types or time periods. Use the **Error Logs** section to diagnose issues: * Each error entry displays the error type, start time, last occurred timestamp, and occurrence count * Click an error entry to open the `Error Details` dialog with the error meaning, suggested actions, start and end times, duration, and individual error log messages with their timestamps * If a data source goes up and down repeatedly, all distinct error occurrences appear in the log * Use the `Export` button to download the raw error list for further assessment or to share with external parties ![Error Details dialog for an Authentication error showing meaning, three suggested actions, timestamps, and error log messages](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-error-details.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=80ada362c8a2ead5519638c09cf957c4) The Error Details dialog provides the error meaning, suggested actions, and individual log entries ### Error category reference Each error in the Health tab falls into one of the following categories. Click a category to see its meaning and suggested actions. > [accordion] Connection Timeout > > The connector tried to reach the external system but did not get a response in time. > > **Suggested actions:** > > 1. Make sure the external system or software is running normally. > 2. Ask your IT team if there were any internet or firewall issues. > 3. If the system is fine but the error continues, let your IT team or system vendor know. > [accordion] Request Timeout > > The external system took too long to answer. > > **Suggested actions:** > > 1. Wait a few minutes. The system may be busy or syncing data. > 2. Check if others using the same system are noticing slowness. > 3. If it happens often, let your IT team or vendor know that the system is responding slowly. > [accordion] Connection Closed > > The link to the external system was cut off during communication. > > **Suggested actions:** > > 1. Check that your internet connection is stable. > 2. Ask IT if there were any brief network drops or server restarts. > 3. If it happens frequently, ask IT to review the connection settings for stability. > [accordion] SSL Handshake Failure > > A secure connection could not be established between systems. > > **Suggested actions:** > > 1. Ask your IT or security team to check if the system's security certificate is still valid. > 2. Make sure the system's website or address uses `https://` and loads normally. > 3. If it is a vendor-managed system, inform their support team about the security link issue. > [accordion] Unreachable Network > > Cloud BMS cannot reach the system at all. > > **Suggested actions:** > > 1. Check if the system can be opened or accessed from your computer. > 2. If it only works when you are on VPN, make sure your VPN is active. > 3. If it is still not reachable, ask your IT team to check the network or firewall. > [accordion] Proxy Down > > A service that helps connect systems is currently offline. > > **Suggested actions:** > > 1. Wait a few minutes. It may come back automatically. > 2. Ask your IT team if any network services or proxies were restarted. > 3. If this happens often, let IT know so they can review the network setup. > [accordion] VPN Down > > The secure tunnel between Cloud BMS and your site is disconnected. > > **Suggested actions:** > > 1. Check that your VPN is active and connected. > 2. If managed by your IT team, ask if there were any VPN restarts or outages. > 3. If the VPN is managed by KODE, it should reconnect automatically. Monitor if it stays down for an extended period. > [accordion] Data Source Down > > The connected system (such as your BAS, CMMS, or CCTV server) is offline. > > **Suggested actions:** > > 1. Check if you can log in to that system directly. > 2. Ask the system owner or vendor if they are performing maintenance. > 3. If it is supposed to be running, ask your IT or the vendor to restart it. > [accordion] Authentication Error > > The username, password, or API key used to connect is no longer valid. > > **Suggested actions:** > > 1. Log in to the source system to make sure the credentials still work. > 2. If the password or API key was changed, update it in Cloud BMS. > 3. If you do not manage credentials, ask your IT or vendor contact to refresh the integration access. > [accordion] Gateway Unreachable > > The local device or gateway that connects your system to Cloud BMS is not responding. > > **Suggested actions:** > > 1. Make sure the gateway or device is powered on and connected to the network. > 2. Ask your on-site IT to confirm it is online and using the correct network cable or Wi-Fi. > 3. If it keeps disconnecting, the site's IT or vendor should inspect the device. ## Monitor data source health The data sources list shows the status of each connection at a glance. Key health indicators include: * **Online/Offline status** reflects whether the data source is actively communicating * **Communication score** indicates the reliability of the connection over time * **Device count** shows how many devices are discovered through this data source * **Last collection** timestamp shows when data was most recently gathered ## Manage data sources ### Bulk actions Click the three-dot menu at the top of the data sources list to access bulk operations. ![Bulk actions menu with options for Test Connections, Discover, and Refresh Cache](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-bulk-actions.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=ef30bf97f7477f4b240d565ac4c2783a) * **Test Connections** tests connectivity for all data sources at once * **Discover** triggers [device discovery](/products/kode-os/device-discovery) across all data sources * **Refresh Cache** clears and reloads cached data from all connected systems ### Individual data source actions Click the three-dot menu on any data source row to access actions for that connection. ![Row actions menu with options for Discover Devices, Discover Schedules, Edit, Duplicate, and Delete](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-row-actions.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=8233fb7b96685ff48aa4b9722b356f75) * **Discover Devices** triggers [device discovery](/products/kode-os/device-discovery) for this data source * **Discover Schedules** discovers schedules from the external system * **Edit** opens the data source configuration for modification * **Duplicate** creates a copy of the data source with the same settings * **Delete** removes the data source and its associated data > [!WARNING] > > Deleting a data source removes its associated devices and points from Cloud BMS. Verify that no active dashboards, schedules, or analytics depend on this data source before deleting. ## Import devices and points from a sheet You can import devices and points into Cloud BMS using a structured spreadsheet, even before the data source connection is established. This unblocks deployment work such as templating, ontology mapping, and graphics while site connectivity (VPN, firewall, routing) is still in progress. Once the data source is connected and discovery runs, previously imported devices and points are treated as existing records and begin collecting data automatically. > [!NOTE] > > Until the data source is connected and discovery completes, imported devices and points have no live values or history. The spreadsheet import uses the same identifiers that discovery produces, so merging happens automatically. ### Import workflow **1. Open the import dialog** Navigate to the data source connector view, click the three-dot menu, and select `Import from Sheet`. ![Import From Sheet dialog showing Download Template link, instructions, and a file upload area](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/kode-os-data-sources-import-from-sheet.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=44f735f46be815743ba69828ccb6b4e0) The Import From Sheet dialog with a link to download the template and a drag-and-drop upload area **2. Download the template** Click `Download Template` in the import dialog. The template includes columns for device identifiers, point identifiers, metadata, and ontology fields. **3. Fill out the template** Populate the template with device and point data exported from the external system (commonly Niagara). The following columns are required: **Required columns** | Column | Description | | - | - | | `Device External ID` | The unique device identifier from the external system | | `Device External Path` | The full path to the device in the external system | | `Device Name` | A human-readable name for the device | | `Point External ID` | The unique point identifier from the external system | | `Point External Path` | The full path to the point in the external system | | `Point Name` | A human-readable name for the point | | `Point Kind` | The point data type (`Number`, `Str`, or `Bool`) | You can also include optional columns for device metadata (`Area`, `Location`, `Zone`, `Device Type`) and point ontology fields (`Ontology Field`, `Display Name`, `Precision`, `COV Tolerance`, `Default Graph`, `Ontology Unit`). > [!TIP] > > You can complete templating and metadata assignment directly in the spreadsheet instead of using the UI. This is faster for large sites with many devices. **4. Upload and import** Upload the completed `.xlsx` file and click `Import`. The import runs as a background job with validation before any data is written. > [!WARNING] > > Only one import job can run per data source at a time. Different data sources on the same building can run imports concurrently. ### Re-upload to update existing records Re-uploading a sheet is fully supported. The system uses a smart upsert approach to decide whether to create or update records. > [tab] Devices > > * New device external IDs are created as new devices > * Existing devices can only have `Area`, `Location`, and `Zone` updated through re-upload > * All other device fields remain unchanged > [tab] Points > > * New point external IDs are created and assigned to the appropriate device > * Existing points are not overwritten > * `Area`, `Location`, and `Zone` changes on the parent device cascade to all of its points > [tab] Virtual devices > > * New virtual device names are created as new virtual devices > * Existing virtual device names are reused, and their `Area`, `Location`, and `Zone` can be updated > * Points with a `Virtual Device Name` value are assigned to that virtual device; points without one remain on the base device ### Start collection after connectivity Once site connectivity is established: 1. Run `Discover Devices` on the data source. 2. Imported devices appear as existing records during discovery. 3. After discovery completes, points begin collecting data normally. ## Troubleshoot connection failures When a data source goes offline, use the following approach to identify the issue. > [!TIP] > > A connector can show **Online** while site VPN, gateway, or point data still fails. Treat list status, Health errors, and on-site VPN state as separate checks. Recent IP or modem changes often explain both tunnel and device issues. **1. Check the health tab** Open the connector view and navigate to the `Health` tab. Review the uptime graph and error logs for recent failures. **2. Review error categories** Click individual error entries to see the category and recommended actions. See the [error category reference](#error-category-reference) for a full list of categories, meanings, and suggested actions. **3. Test the connection** Click `Test Connection` to verify that Cloud BMS can reach the external system. A failed test confirms the issue is at the connection level. **4. Verify external system status** Confirm that the external controller, gateway, or server is powered on and connected to the network. Check for IP address changes, credential rotations, or firewall modifications. > [!NOTE] > > Brief connectivity alerts sometimes clear within a few minutes with no data loss. If the Health tab shows a short outage that already recovered, confirm devices and points stayed online before escalating. > > Cloud BMS maintains the VPN tunnel and platform uptime on its end. Connectivity failures at the device, controller, or BMS server level are typically resolved by checking the on-site infrastructure. Contact KODE Labs support at [support@kodelabs.com](mailto:support@kodelabs.com) if you need assistance with troubleshooting. ## Next steps > [card] [FDD events](/products/fdd/events) > > View, acknowledge, and investigate subsystem alarms alongside routine events. > [card] [Device discovery](/products/kode-os/device-discovery) > > Scan data sources to register devices and points in Cloud BMS. > [card] [Devices](/products/kode-os/devices/devices) > > View and manage the equipment discovered through your data sources. # Device discovery Source: https://docs.kodelabs.com/products/kode-os/device-discovery Discover devices and points from your data sources and register them in Cloud BMS. > [!NOTE] > > Device discovery is a building-level feature. Select a building from the [sites list](/products/kode-os/sites-and-map) before starting discovery. Device discovery identifies equipment integrated into a [data source](/products/kode-os/data-sources) and registers it in Cloud BMS. The process scans the external system, returns a list of devices and points, and lets you select which ones to add to the database. ## Start discovery You can start discovery from two locations. Shared results and Activity Log behavior are the same for both paths. > [tab] All data sources > > **1. Open data sources** > > Navigate to your building and click **`Data Sources`** in the left navigation bar. > > **2. Start bulk discovery** > > Click the three-dot menu to the right of the search bar and select **`Discover`**. Select the data sources you want to discover and click **`Next`**. Wait for the discovery process to complete. > [tab] Single data source > > On the **Data Sources** page, click the three-dot menu on the data source row and select **`Discover Devices`**. The discovery process runs against that data source only. > > ![Data Sources page showing TR Fisnik data source with row three-dot menu open, listing Discover Devices, Discover Schedules, Edit, Duplicate, and Delete options](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-datasource-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=b818cb7ba855fda88467a2dc3cb3d609) > > Select Discover Devices from the data source row menu to start discovery After discovery starts, the **Activity Log** appears in the lower right corner. It shows the discovery job name, data source, and status. You can expand, collapse, or move the Activity Log while discovery runs. You can also navigate to other modules without interrupting progress. Wait for the status to show **Completed** before reviewing results. ![Activity Log panel showing one entry for TR Fisnik with a green Completed status badge and navigation arrow](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-activity-log.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0cd37e9a6b1805955562676718fe8555) The Activity Log confirms when the discovery job finishes ## Discovery results After discovery completes, the **Device Discovery** page displays five tabs. Each tab shows a count badge with the number of items it contains. | Tab | Contents | | - | - | | **Conflicts** | Devices or points that exist in Cloud BMS but can no longer be found in the data source. Includes possible duplicates and unmatched points. | | **New Devices** | Devices not yet registered in Cloud BMS, ready to be added. New here means new to the Cloud BMS database, not newly added on the source controller. | | **Existing Devices** | Devices already in Cloud BMS, including any new points discovered on them. | | **Point Updates** | Existing points whose properties (facets, writability, or unit) changed since the last discovery. | | **Device Name Updates** | Devices whose names changed in the external system since the last discovery. | Use **`Restart discovery`** to re-run discovery, or **`Complete Discovery`** to finalize the process. Each tab includes an **`Export`** button to download its contents. > [!WARNING] > > Adding devices to the database is not the final step. After you finish selecting devices, click **`Complete Discovery`**, then **`Refresh Cache`**. If you skip Refresh Cache, devices can appear in Cloud BMS while data collection never starts. You can also run Refresh Cache later from the [data source](/products/kode-os/data-sources) connector menu. ## New devices The **New Devices** tab lists devices that are not yet in Cloud BMS. Filter by **All** to see every new device, or **Possible Duplicates** to see devices that may already exist under a different identifier. You can browse these devices in two views: * **Devices List** -- shows each device as a row with its path and new point count. Click the copy icon to copy a device path. Expand a device to see its individual points. ![Device Discovery page on the New Devices tab in Devices List view, showing FCU devices with their BACnet paths, copy icons, and 20 new points each, with All 16 and Possible Duplicates 0 filter tabs](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-new-devices.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=4f601b31459071fb39be5f89344b2bb7) Devices List shows each device with its path and the number of new points * **Grouped Points** -- groups results by point name. Each row shows how many new devices and new points share that name. Expand a point name to see the individual devices. ![Device Discovery page in Grouped Points view showing point names like ZN\_T\_SP and SA\_T with columns for Number of New Devices and Number of New Points](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-grouped-points.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=0a89d02458d6ac7ab20367d20aa4fe4d) Grouped Points organizes results by point name across all discovered devices ### Add devices to the database **1. Select devices and points** Check the devices and points you want to register. The selection count appears above the table (for example, "3 device(s) selected on this page"). Click **`Select all devices in New Devices`** to select everything across all pages. ![Device Discovery New Devices tab with three FCU devices checked, each showing a blue 20 badge for selected points, and a message showing 3 devices selected with an option to select all devices](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-new-devices-selected.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=f38dee09227d9f92794ce787cca65189) Selected devices display a point count badge and the selection summary appears above the table **2. Add to database** Click **`Add to Database`**. The selected devices and points are registered in Cloud BMS and move to the **Existing Devices** tab. > [!TIP] > > You can add devices incrementally. Select a few devices, click **`Add to Database`**, then return to add more from the remaining list. ## Existing devices The **Existing Devices** tab shows devices already registered in Cloud BMS. It supports both **Devices List** and **Grouped Points** views, plus **Filters** for narrowing results. It contains three sub-tabs: | Sub-tab | Contents | | - | - | | **All** | Every discovered device with all its points. | | **New Points** | Devices that have new points not yet added to Cloud BMS. | | **With Conflicts** | Devices with at least one unmatched point. You cannot add new points for these devices until you resolve the conflicts. | ![Device Discovery Existing Devices tab with New Points sub-tab selected showing 37 devices, VAV devices listed with BACnet paths, 16 new points each, Devices List and Grouped Points toggle, Filters button, and Export button](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-existing-devices.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=b29fa7d88c04845bcd5584301884f7c2) The Existing Devices tab with New Points sub-tab showing VAV devices with 16 new points each Expand a device row to see its individual points. Select the device and its points, then click **`Add to Database`** to register the new points. ![Existing Devices tab with VAV\_303 expanded showing four new points with BACnet paths including Htg\_Cmd, HTG\_Enable, HTG\_PI, and Cooling\_PI, all selected with checkboxes, and Add to Database button at the bottom right](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-existing-expanded.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=3ceb751dcd448633d97b6793075f5984) Expand an existing device to select new points for registration ## Conflicts Conflicts occur when Cloud BMS has previously discovered a device or point, but can no longer find it in the data source. Common causes include: * Renaming a device or point in the external system * Changing a device or point location in the external system * Deleting and re-adding a device or point in the external system These orphaned devices and points remain in a **Down** status because Cloud BMS cannot communicate with them. When the renamed or relocated version appears during discovery, it comes in as a new device. Adding it without resolving the conflict creates duplicate data. Cloud BMS marks a device as a **possible duplicate** when it detects that a newly discovered device may already exist in the database under a different identifier. The **Conflicts** tab lists devices that have been rediscovered. Each row shows the device name, path, and the number of unmatched points. Expand a device to see its unmatched points, including any virtual device references. ![Conflicts tab showing AHU\_3 edit device with 1 Unmatched Points, expanded to show HtgVlv\_out Virtual point with its BACnet path, with Auto Suggest button, Filters, and Export controls](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-conflicts-expanded.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=048c8733781617598676f1e80970820c) The Conflicts tab showing a device with one unmatched point expanded to reveal the virtual device detail ## Merge devices Merging resolves conflicts by pairing unmatched points from the old device record with their counterparts on the rediscovered device. ### Merge a single device **1. Open the matchmaking view** On the **Conflicts** tab, click the **`Match Points`** icon (two arrows) on the device you want to merge. ![Conflicts tab showing AHU\_3 edit device with 1 Unmatched Points and the Match Points button tooltip visible on the two-arrows icon](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-conflicts-match-points.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=d7da02c63ff17572ee5f3dfb0bb06101) Click Match Points on a conflict row to start the merging process **2. Match points** The **Matchmaking** view opens. If a match is found, **Auto Suggest Points** runs automatically and pairs the points for you. You can also drag and drop points manually into the **Paired Points** area to create or adjust pairings. The left panel shows the device on Cloud BMS with its **Unmatched Points**, **New Points**, and **Existing Points**. The right panel shows **Paired Points** that will be merged. Click **`Save`** to apply the merge. ![Matchmaking dialog for AHU\_3 edit showing Unmatched Points section with Drop all button, New Points with DX1\_S and And listed, Existing Points count of 66, and Paired Points on the right with HtgVlv\_out Virtual paired with HtgVlv\_out, plus Show original point names, Add Device Match, How to merge, and Auto Suggest Points controls](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-matchmaking.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=709ac4557e93fbd90534ed68a305bf4d) The Matchmaking view shows unmatched and new points on the left, paired points on the right **3. Add a device match** Click **`Add Device Match`**. The **Device Match Selection** dialog opens with a searchable list of devices. Select the device you want to pair with and click **`Add`**. ![Device Match Selection dialog with search bar, device table showing IEQ\_02, IEQ\_05, IEQ\_06, and IEQ\_04 with 12 New Points each, and Cancel and Add buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-device-match-selection.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=59e1cc42ddd0ed65f0a98d0ffa37d1ca) Search and select the device to pair with from the Device Match Selection dialog > [!NOTE] > > Only points within created pairs are merged. No updates are applied to other points. Drag and drop points to the specified area to merge them. ### Global auto-suggest When many devices have conflicts, click **`Auto Suggest`** on the **Conflicts** tab to run the matching process across all unmerged devices at once. The **Devices Autosuggest** page displays results with a **Match Status** for each device. Filter by **All**, **Match Found**, or **Match Not Found**. Click **`Step by Step Merging`** to review each device individually. Confirm or adjust the suggested pairs, then proceed to apply each merge. ![Devices Autosuggest page with sub-tabs for All 1, Match Found 1, and Match Not Found 0, showing AHU\_3 edit device with Match found status, and Step by Step Merging button in the upper right](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-autosuggest.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=3df0a21b306727c64c0f0d5aba89260d) Devices Autosuggest shows the match status for each conflicting device with a Step by Step Merging option ## Point updates The **Point Updates** tab shows existing points whose properties differ from the last discovery. Filter results using the sub-tabs: | Sub-tab | Contents | | - | - | | **All** | Every point with a property change. | | **Facet Update** | Points with changed boolean or enum values (for example, `Occ, Unocc` becomes `Occupied, Unoccupied`). | | **Name Update** | Points whose name changed in the external system. | | **Unit Update** | Points whose unit of measurement changed (for example, `°C` becomes `°F`). | | **Writability Update** | Points whose writability setting changed (for example, read-only becomes writable). | The table displays **Point**, **Device**, **Update Type**, and **Update Status** columns. The **Update Status** column shows the old and new values (for example, `°F > null`). Select the points you want to sync and click **`Update points`** to apply the changes to Cloud BMS. ![Point Updates tab with sub-tabs for All 92, Facet Update 0, Name Update 2, Unit Update 80, and Writability Update 10, showing a table of points from VAV\_101 with Unit Update type and Update Status showing °F to null](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-point-updates.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=70086d4e190b69af731e92d2a0a30a6a) Point Updates shows each changed point with its update type and the old-to-new value transition ## Device name updates The **Device Name Updates** tab shows devices whose name changed in the external system since the last discovery. The table displays the **Current Name (KODEOS)** alongside the **Updated Name (Data Source)** with the device path. Select the devices you want to update and click **`Update Devices`** to sync the names in Cloud BMS. ![Device Name Updates tab showing three devices with Current Name KODEOS column listing FCU\_304 TEST, FCU\_2051, and FanCoilUnit\_I05, and Updated Name Data Source column listing FCU\_304, FCU\_205, and FCU\_105 with their BACnet paths](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-device-name-updates.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=dc0db4f6101b90681f0f0e1792b04cae) Device Name Updates compares the current Cloud BMS name with the updated name from the data source ## Export discovery results Each tab includes an **`Export`** button. Click it to open the export dialog where you set a **File Name**, choose an **Export Type** (for example, `Export Devices`), and select which **Columns** to include. Click **`Export`** to download the file. ![Export dialog with File Name field, Export Type dropdown set to Export Devices, Columns dropdown set to All Columns, and Cancel and Export buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/data-sources/discovery/kode-os-discovery-export.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=e227843b935acb446f4e3ea3012b5f7a) The export dialog lets you name the file, choose the export type, and select columns Each tab exports its own data: * **Conflicts** -- devices or points with conflicts * **New Devices** -- list of new devices or new points * **Existing Devices** -- list of new points on existing devices * **Point Updates** -- points with updates, including details on what changed ## Next steps > [card] [Data sources](/products/kode-os/data-sources) > > Configure and monitor your data source connections. > [card] [Devices](/products/kode-os/devices/devices) > > View and manage the equipment registered through discovery. # Copied points Source: https://docs.kodelabs.com/products/kode-os/devices/copied-points Duplicate point values between devices so sensors and setpoints stay shared across equipment without templating workarounds. Copied points let you mirror one or more points from a source device onto other devices in a single batch operation. You do not need to template devices or set up cross-references between source and target equipment. The copy reflects the source point in real time. You can expose the same sensor or setpoint on multiple devices without reconfiguring the data source. Unlike moving points on virtual devices, copying keeps the point on the **source** device and adds it to **target** devices. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR SRC[Source Device] -- "owns" --> PT[OA Temp Sensor] PT -- "copied to" --> T1[Target Device A] PT -- "copied to" --> T2[Target Device B] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef rose stroke:#FF5978,fill:#FFDFE5,color:#8E2236 classDef green fill:#B0E4CC,color:#285A48,stroke:#285A48 class SRC sky class PT rose class T1,T2 green ``` ## Use cases Copied points help when you need to: * Share a sensor reading (for example, outdoor air temperature) across multiple devices * Mirror a setpoint into another device for dashboards or logic * Surface a shared sensor on downstream equipment without cross-referencing * Duplicate setpoints or sensors on major water systems where multiple devices use the same value > [!NOTE] > > You can copy points only from **original (physical) devices**. Copying from virtual devices is not supported. ## Copy points from batch update The main workflow starts on **Devices** and uses **Batch Update Devices** → **Copied Points** → **Copy Points**. ### Open Devices and batch update In the sidebar, select **`Devices`** to open the devices list for your site. ![Cloud BMS sidebar with Devices highlighted at the bottom, showing device count next to Systems, Spaces, Tenants, and Points](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-sidebar-devices.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=63cb72df72738d3e0993add8497e7aae) Choose Devices in the sidebar to open the devices table On the **Devices** page, click **`Batch Update Devices`** in the upper right corner. ![Devices list with search, filters, device table, and Batch Update Devices button highlighted in the upper right corner](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-batch-update-button.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=74d31abce39abc5f7f515d21cbbf20b6) Batch Update Devices opens the batch workspace where Copied Points lives ### Open Copied Points and start the wizard In the batch update sidebar, click **`Copied Points`**. The page lists existing copies with **SOURCE POINT**, **SOURCE DEVICE**, and **TARGET DEVICES**. Click **`Copy Points`** in the upper right to start the wizard. ![Copied Points page with sidebar showing Batch Update, Device Referencing, Virtual Devices, Linked Devices, Copied Points selected, search bar, Copy Points button, and table columns for source point, source device, and target devices](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-page.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=6a3160e2b0c182210dde3c7da993a36b) The Copied Points page lists copies and provides the Copy Points action ### Step 1: Select source device The **Copy Points** wizard opens on **Select Source Device**. Search or filter the table, select **one** source device (radio selection), then click **`Next`**. ![Copy Points wizard step 1 with stepper, search devices by Name, Filters, device table with radio selection, and VAV\_410 selected as source](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copy-points-select-source-device.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=e0feea684ad0919da5f7ba90ed8be242) Select exactly one device to copy points from ### Step 2: Select points to copy On **Select Points to Copy**, use the search bar and select **one or more** points with the checkboxes. Click **`Next`**. ![Copy Points wizard step 2 showing points table with checkboxes, columns for point name, point type, and field, with several numeric points selected](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copy-points-select-points.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=513b2524c196f871a832078ac704d298) Choose which points on the source device to duplicate ### Step 3: Select target devices On **Select Target Devices**, search or filter, then select **one or more** target devices with the checkboxes. Click **`Next`**. ![Copy Points wizard step 3 with device table, header checkbox showing partial selection count, and multiple target devices checked](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copy-points-select-target-devices.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=1f330bd7bb5873fb56996569ba3004b6) Pick every device that should receive a copy of the selected points ### Step 4: Review and confirm On **Review & Confirm**, use the tabs **To be copied**, **Copy exists**, and **Copy limit reached** to review the proposed copies. When the list looks correct, click **`Copy Now`**. > [!NOTE] > > Each building supports up to **1000** copied points. Rows that exceed this limit appear on the **Copy limit reached** tab and are not added until you remove existing copies. ![Copy Points wizard step 4 with summary table of source point, source device, target device, status To be copied, and Copy Now button](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copy-points-review-confirm.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=4393ca9062da0f3a5d32b4dc409f2d68) Review the matrix of source points and target devices before running the copy After the operation completes, the results screen summarizes what ran. Copied points appear on the selected targets and show up on the **Copied Points** list. ## Copy a point from device details You can start a copy from a single device without opening **Copied Points** first. This path does not list points that are already duplicated in the building. To audit or manage existing copies, use the **Copied Points** page under **Batch Update Devices**. Open the device from **`Devices`**, then click the **`Device Details`** tab on the device page (alongside **Trends**, **Graphic**, and other tabs). ![Device page for VAV\_407 showing tabs for Switch to old version, Trends, Graphic, Work Orders, FTT, and Device Details highlighted in the top-right, with a points list on the left and trend chart area on the right](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-device-details-tab.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=04414a9732ec0ad7a4d0e6927296e0bd) Open Device Details from the tab bar on the device page On the **Device Details** panel, click **`Edit Points`** next to the points count. ![Device Details panel showing Connector, Canonical Type, Type, Location, Device Class, Tenant, Site Level, Points count of 27 with Edit Points link highlighted, Serial Number, Identifier, and other metadata fields](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-edit-points-link.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=eb76054cfd1877212fbf4d5dd85b5a82) Edit Points opens the point editor for this device On **Edit Points**, select the point in the list. In the right panel, click **`Duplicate Point`** (two overlapping squares). ![Edit Points view for VAV\_407 with 27 points listed on the left showing name, value, status, and point type columns, and ZN\_T\_SP configuration panel on the right with Display Name, Unit, Tags, Min and Max Value, COV Tolerance, Precision, Metadata, Allow writability toggle, and Duplicate Point button highlighted at the bottom](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-edit-points-duplicate.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=a607ad7c8a9dea9634b3745ff7cd4045) Duplicate Point starts the copy dialog for the selected point In the **Copy Point** dialog, use **Search devices by Name**, **Filters**, and tabs such as **Referenced Devices** when shown. Select **one or more** targets, then click **`Copy Now`**. ![Copy Point dialog for Adjust Value from VAV\_407 with search bar, Filters button, Referenced Devices tab, sortable device table showing Device, Device Type, Ontology Type, Data Source, Area, and Points columns with IEQ\_02 selected, pagination showing 314 devices, and Cancel and Copy Now buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-copy-point-modal.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=b2a6bedf646cfefae453ca8922d20804) Search and filter devices, scope with Referenced Devices when available, then confirm ## Point behavior after duplication | Scenario | What happens | | - | - | | Source point value changes | Copies on all targets update in real time | | Source point is deleted | The copy is removed from every target | | Source device is deleted | All copies of its points are removed from every target | | Copy is deleted on a target | Only that target loses the copy; the source and other targets are unchanged | | Source point was templated | The copy on the target is **not** templated; the duplication relationship is what ties it to the source | ## Remove copied points Go to **`Devices`** → **`Batch Update Devices`** → **`Copied Points`**. Select **one or more** rows with the checkboxes. The toolbar shows **`Delete Duplicated Points`** with a count of selected rows—click it to remove those copies from their targets. ![Copied Points table with one row selected and Delete Duplicated Points button showing the selection count at the bottom of the page](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-delete-selected.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=5ff46ec75b2671c48ad6f82035dd3843) Select rows on Copied Points, then use Delete Duplicated Points You can also open the row **three-dot** menu and choose **`Delete Duplicated Points`** for that row only. ![Copied Points row with three-dot menu open showing View Target Devices and Delete Duplicated Points options, with target devices column showing a linked device count](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-row-menu.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=13bdd6062e51db488d1699f94a3b4168) Row menu includes View Target Devices and Delete Duplicated Points ## View or manage target devices From the **Copied Points** list: * Click the link in **TARGET DEVICES** when copies exist (for example **`4 Devices`**), or * Open the row **three-dot** menu and choose **`View Target Devices`**. The **View Target Devices** page lists every target that receives the copy for that source point and device. From there you can: * Click **`+ Copy to New Devices`** to copy the same point to additional devices. * Select targets and click **`Remove Selected`** to drop those copies, or use the **minus** control on a row to remove one target. ![View Target Devices page with subtitle showing source point and device, search bar, Copy to New Devices button, table of target devices with checkboxes, and Remove Selected button](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-copied-points-view-target-devices.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=f23689b6c18bb7b9ccbca0edc2069ab6) View Target Devices lists targets and supports Copy to New Devices or Remove Selected ## Copy history on the Copied Points page The **Copied Points** page lists copy activity for the building. Each entry shows the source point, source device, target device or devices, and when the copy ran. Use it to audit shared points and ongoing duplication. ## Next steps > [card] [Batch update devices](/products/kode-os/devices/device-batch-update) > > Filter devices and run bulk updates from the batch update workspace. > [card] [Points overview](/products/kode-os/points/points) > > Understand point types, normalization, and how copied points fit in. # Batch update devices Source: https://docs.kodelabs.com/products/kode-os/devices/device-batch-update Make mass edits to device metadata, area assignments, and templates across multiple devices at once. Batch update allows you to make changes to multiple devices simultaneously. Use it when you need to rename devices, reassign areas, apply templates, or update device properties across a group of equipment. ## Open batch update Navigate to **Devices** from the left sidebar. Click **Batch Update Devices** in the upper right corner of the devices list. ![Devices list page showing the Batch Update Devices button in the upper right corner, with a list of FCU, AHU, and VAV devices filtered to show devices with points](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/devices/kode-os-devices-batch-update-entry.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=b04ca39957200e5deeb08df90458aeac) Click Batch Update Devices from the Devices list to open the batch update page The batch update page displays all devices in a table with columns for name, type, ontology type, area, location, device class, zone, tenant, and point count. Use the search bar to find devices by name, path, or location. Click the search options icon to switch between **Starts With**, **Contains**, or **Exact** matching and choose which fields to search. ![Search Options panel showing Starts With, Contains, and Exact match modes, and Fields toggles for Name, Path, and Location](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-search-options.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=8efa801b204652d1641bcd36d1b72816) Search options let you control match mode and which fields are searched A bottom toolbar provides quick actions for the selected devices. ![Devices Batch Update page with one device selected, showing columns for Name, Type, Ontology Type, Area, Location, Device Class, Zone, Tenant, and Points, with Delete, Find and Replace, Apply graphics, Model Devices, and Batch Update buttons at the bottom](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-overview.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=21c447a7530f8ceb985ee7fa0f93a03b) The batch update page shows all devices with selection checkboxes and a bottom action toolbar ## Filter devices Use the filter bar at the top of the page to narrow down the device list by **Type**, **Ontology Type**, **Area**, or **Data Sources**. Click **More** to access additional filters. ![More filters dropdown showing Origin Type, Pseudo Devices, Point Count, and Quick Filters options](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-more-filters.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=9db0a474bb3c360227a70946bb18ff43) The More menu provides additional filters for Origin Type, Pseudo Devices, Point Count, and Quick Filters Select **Quick Filters** to quickly find devices that need attention, such as devices without an area, without a type, with non-matching ontology, or without templated points. ![Quick Filters submenu showing Without Area 9, Without Type 1, With Not Matching Ontology 38, and Without Templated Points 3](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-quick-filters.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=dc9f671c9a29d0e11397e30229fc7492) Quick Filters let you find devices that are missing metadata or have modeling issues ## Update device properties Select the devices you want to update by checking the boxes next to each device name, or click **Select all** to select every device that matches your filters. The **Properties** panel appears on the right side where you can set values to apply in bulk. ![Batch Update page with all 39 VAV devices selected and a Properties panel on the right showing fields for Type, Area, Tags, Location, Device Class, Tenant, Zone, Is Pseudo Device, and Site Level, with Clear Inputs and Apply buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-properties.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=d595c353757adb5e3c27a4ea31e846ff) Select devices and use the Properties panel to update type, area, tags, location, device class, tenant, zone, and other settings Set the values you want to apply, then click **Apply** to update all selected devices. Click **Clear Inputs** to reset the properties form. | Property | Description | | - | - | | **Type** | The device type classification | | **Area** | The floor, zone, or room assignment | | **Tags** | Metadata tags applied to the devices | | **Location** | The physical location description | | **Device Class** | The device classification category | | **Tenant** | The tenant associated with the devices | | **Zone** | The zone assignment | | **Is Pseudo Device** | Whether the device is a virtual or pseudo device | | **Site Level** | Whether the device operates at the site level | ## Batch actions The bottom toolbar provides additional actions for selected devices: | Action | Description | | - | - | | **Delete** | Remove devices, graphics, or ontology mappings | | **Find & Replace** | Search and replace text in device names | | **Apply graphics** | Assign graphic templates to the selected devices | | **Model Devices** | Open the Points Modeling page for the selected devices | | **Batch Update** | Apply property changes from the Properties panel | ### Delete Click the **Delete** dropdown to choose from several removal options: ![Delete dropdown showing Delete Devices 39, Remove Graphics 39, Remove New Graphics 39, and Remove Ontology 39](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/devices/kode-os-devices-batch-update-delete-menu.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=58f62f013b73569c3ecf7a1b49e0e3f2) The Delete menu lets you remove devices, graphics, or ontology mappings in bulk | Option | Description | | - | - | | **Delete Devices** | Permanently remove the selected devices | | **Remove Graphics** | Remove assigned graphics from the selected devices | | **Remove Ontology** | Clear ontology mappings from the selected devices | ### Find and replace Click **Find & Replace** to open the find and replace dialog. Enter the text to find in existing device names and the replacement text, then click **Replace** to rename all matching devices at once. ![Find and Replace dialog with Find and Replace fields, showing Replace 39 button to apply changes to all selected devices](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-batch-update-find-replace.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=9dba2c1c8150359c484d53bddfa8f267) Find and Replace lets you search for text in device names and replace it across all selected devices ### Export devices Click **Export** at the top of the page to download device data. Enter a file name, select the columns to include, and click **Export** to generate the file. ![Export dialog showing File Name field and Columns selector with 7 columns selected, with Cancel and Export buttons](https://mintcdn.com/kodelabs/qpy9KTqZYAZmFRi5/images/kode-os/devices/kode-os-devices-batch-update-export.png?fit=max\&auto=format\&n=qpy9KTqZYAZmFRi5\&q=85\&s=2971ff0c7a4d9a45b69d8fbee2d1c7e5) The Export dialog lets you choose a file name and select which columns to include > [!WARNING] > > Batch operations affect multiple devices at once. Review your selections carefully before applying. Reassigning areas or applying templates may affect dashboards, schedules, and analytics that reference these devices. ## Next steps > [card] [Device templates](/products/kode-os/devices/device-templates) > > Create reusable configurations to apply during batch updates. > [card] [Devices](/products/kode-os/devices/devices) > > Return to the devices overview for individual device management. # Device referencing Source: https://docs.kodelabs.com/products/kode-os/devices/device-referencing Create a digital twin of your building by linking devices according to their physical and functional relationships. Device Referencing in Cloud BMS enables the creation of a digital twin for a building's systems by linking devices according to their physical and functional relationships. This interconnected digital model mirrors real-world interactions, such as how one device supplies air, water, or power to another, or how meters monitor specific equipment. ![Diagram showing device relationships including coolingTower, chiller, loopSystem, boiler, generator, ahu, fcu, vav, cav, and various meters connected by feeds, isFedBy, hasPart, isPartOf, measures, and isMeasuredBy references](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-diagram.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=15f3a5eeeeafbd7be47babe6238a3330) Device referencing maps physical and functional relationships between building systems and equipment ## Why device referencing matters Device referencing transforms raw device data into a structured, relational framework that enhances building management: * **Diagnostics and troubleshooting** — By mapping device connections, operators can swiftly trace issues. For instance, if a VAV unit malfunctions, its relationship to an AHU via a `feeds` reference can pinpoint the source of the problem. * **Fault Detection and Diagnosis (FDD)** — The system leverages these references to generate contextual alarms, considering not just individual devices but their interconnected dependencies, offering a holistic view of system health. * **Energy analysis** — Linking meters to the devices they measure enables detailed energy consumption insights, empowering operators to optimize efficiency and reduce costs. ## Reference types Reference types define the specific nature of relationships between devices. Each reference type has a corresponding reverse reference, automatically establishing a two-way connection. For example, if you connect an AHU to a VAV using the `feeds` reference, the VAV will automatically show an `isFedBy` reference back to the AHU. ### HVAC references > [tab] feeds / isFedBy > > **feeds** indicates that a device supplies an output (air, water, power) to another device or system. > > **Reverse reference:** `isFedBy` > > **isFedBy** indicates that a device receives an input from another device or system. > > **Reverse reference:** `feeds` > > **Examples:** > > * An AHU `feeds` a VAV — the AHU provides air to the VAV > * A VAV `isFedBy` an AHU — the AHU supplies air to the VAV > * An AHU `isFedBy` a Chilled Water System — the chilled water system supplies water to the AHU for cooling > [tab] hasPart / isPartOf > > **hasPart** denotes that a device or system includes another device as a component or subsystem. > > **Reverse reference:** `isPartOf` > > **isPartOf** indicates that a device is a component or subsystem within a larger device or system. > > **Reverse reference:** `hasPart` > > **Examples:** > > * A chilledWaterSystem `hasPart` a chiller — the chiller is a component of the system > * A chiller `isPartOf` a chilledWaterSystem — the chiller belongs to that system ### Metering references > [tab] measures / isMeasuredBy > > **measures** indicates that a meter monitors the performance or consumption of a device or system. > > **Reverse reference:** `isMeasuredBy` > > **isMeasuredBy** specifies that a device's performance or consumption is monitored by a meter. > > **Reverse reference:** `measures` > > **Examples:** > > * An electricMeter `measures` an AHU — it tracks the AHU's electrical consumption > * An AHU `isMeasuredBy` an electricMeter — the meter tracks the AHU's electrical usage > [tab] hasSubmeter / isSubmeterOf > > **hasSubmeter** indicates that a meter has another meter as its submeter. > > **Reverse reference:** `isSubmeterOf` > > **isSubmeterOf** specifies that a meter is a submeter of another meter, often in hierarchical metering setups. > > **Reverse reference:** `hasSubmeter` > > **Examples:** > > * A main electricMeter `hasSubmeter` a submeter — it oversees the submeter > * A submeter `isSubmeterOf` a main electricMeter — it reports to the main meter ### API references > [tab] mirrors / isMirrorOf > > **mirrors** indicates that a device mirrors another device via an API connection. > > **Reverse reference:** `isMirrorOf` > > **isMirrorOf** indicates that a device is a mirrored or API-referenced version of another device, typically for integration with external systems. > > **Reverse reference:** `mirrors` > > **Examples:** > > * A device `mirrors` an external device — it reflects its data in Cloud BMS > * A device `isMirrorOf` another device in an external system — it replicates its data ## Example reference flows The following diagrams illustrate common device referencing patterns in building systems. ### Chilled and condenser water systems A condenser water system feeds a chilled water system, which in turn feeds downstream equipment like AHUs, FCUs, and water systems. Components like cooling towers, heat exchangers, and pumps are parts of each system. ![Flow diagram showing Condenser Water System with Cooling Tower, Heat Exchanger, and Pump as parts, feeding into Chilled Water System with Chiller, Heat Exchanger, and Pump as parts, which feeds Water System, AHU, and FCU downstream](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-chilled-water.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=b763c8f19bcfa423f1373dddec5b5032) Condenser and chilled water systems connected by feeds references, with components linked by isPartOf ### Hot water system A hot water system contains boilers, heat exchangers, and pumps as components, and feeds AHUs and FCUs, which in turn feed VAVs. ![Flow diagram showing Hot Water System with Boiler, Heat Exchanger, and Pump as parts via isPartOf, feeding AHU and FCU, with AHU feeding VAV](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-hot-water.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=e16f153e260967204d84b60f26e21389) Hot water system feeding AHUs and FCUs, with boiler, heat exchanger, and pump as components ### Metering hierarchy Meters follow a hierarchical structure where site meters have submeters, and each submeter measures specific devices. ![Metering diagram showing Site Meter at top, connected to Sub Meter via isSubmeterOf, with Sub Meter using measures references to connect to Chiller and all other device types](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-metering.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=d491af80d851eb7dadde06619b8c244d) Metering hierarchy showing a site meter with a submeter that measures individual devices ## Manage device references Navigate to **Devices** > **Device Referencing** from the building left sidebar. The page lists devices so you can add **device references** (device-to-device) and **space references** (device-to-space). ![Device Referencing page with search and filters for Ontology Type Level Located In Data Sources Origin Type, status counts for devices without references and without space references, device table with Show References links, and Add Space References and Add Device References buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-page.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=1ac53b4d130ddc8f7dd880e294d18de1) Device Referencing page with filters and reference status Use **search for devices by name** and the filter dropdowns to narrow the list: | Filter | Purpose | | - | - | | **Ontology type** | Limit to a canonical device type | | **Level** | Filter by floor or level | | **Located in** | Filter by physical space assignment | | **Data sources** | Filter by connector or source | | **Origin type** | Filter by discovery origin | Status indicators at the top summarize reference health, including devices **without references** and **partially referenced**. Apply tags such as **with points** when you only want devices that have point data. The table shows **name**, **ontology type**, and **device reference** count. Click **show references** on a row to open that device's reference detail view. ### Add device references to multiple devices **1. Select devices** Check the boxes next to the devices you want to add references to. Click **Add Device References** at the bottom of the page. ![Device Referencing page with two FCU devices selected and an Add Device References button at the bottom showing the count of selected devices](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-select-devices.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=65dae00096a29cc69c62273fcef66718) Select devices and click Add Device References to begin adding references in bulk **2. Choose the reference type** In the **Add References to Multiple Devices** dialog, select a reference type from the dropdown. References are grouped into **Inputs** (isMeasuredBy, isFedBy, isMirrorOf, isMonitoredBy) and **Outputs** (mirrors). ![Add References to Multiple Devices dialog with Reference Type dropdown showing Inputs (isMeasuredBy, isFedBy, isMirrorOf, isMonitoredBy) and Outputs (mirrors)](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-type-dropdown.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=e4db46c9f3053b82ca513e313c69f439) The reference type dropdown groups available references into Inputs and Outputs **3. Select the target device** After choosing a reference type, the dialog shows a list of compatible devices. Filter by name, ontology type, or area to find the target device, then select it and click **Add**. ![Add References dialog with isFedBy selected, showing a list of AHU and loopSystem devices with columns for Name, Ontology Type, Area, and References, with AHU\_3 selected](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-select-target.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=446b699ba541452ec7805ac1f875ad03) Select a target device from the filtered list of compatible devices ### View and drill into references Click **Show References** on any device to see its current references. The detail view shows each reference grouped by type (for example, `isFedBy`) with the referenced device's name, ontology type, and reference counts. ![References for FCU208 showing an isFedBy reference to AHU\_3 with ontology type ahu, 10 device references, 2 missing references, and 69 points](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-device-detail.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=537cae9719f216a2078caacc24848d57) The reference detail view for a device shows its references grouped by type > [!NOTE] > > A **Missing references** count can still appear after you add expected relationships. Cloud BMS compares against the full expected reference set for the device type. The count does not always mean your referencing work is incomplete. Click **Show References** on a referenced device to drill deeper into the reference chain. For example, clicking into AHU\_3 shows all the devices it feeds. ![References for AHU\_3 showing feeds references to FCU208, FCU\_2\_GS\_TEST8, and multiple VAV devices across Floor 2 and Floor 3, with Remove references and Add references buttons at the bottom](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-drill-down.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=cd41cf6a04be6149319132a39ec0b0ba) Drilling into AHU\_3 shows all devices it feeds, including FCUs and VAVs From the reference detail view you can: * Click **Add references** to add more references to the device * Click **Remove references** to delete existing references * Click the external link icon next to the device name to navigate directly to that device ### View references from device details References are also available on a device's **Device Details** tab. The **Referenced Devices** section lists all references with their name, reference type, and device type. From here you can add new references with the **+ Add** button or delete existing ones with the delete icon. ![FCU208 Device Details tab showing the Referenced Devices section with AHU\_3 listed as isFedBy reference with device type ahu, and Add and delete buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-device-details-references.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=7b4582af86530ec6c2ea57ba020b4401) The Device Details tab shows referenced devices with options to add or delete references ### View referenced points on trends You can overlay referenced device points directly on a device's **Trends** tab. Click **Referenced Devices** in the device header to open the referenced devices panel on the right. The panel lists all references grouped by type (for example, `isFedBy`), along with the referenced device's points. Select a referenced device's points to overlay them on the trend charts. Referenced point data appears as **dashed lines** on the chart, making it easy to distinguish from the device's own point data. ![FCU208 Trends tab showing Temperature, Mode, and Status charts with AHU\_3 Supply Air Temp Setpt displayed as a dashed line, and the Referenced Devices panel on the right showing isFedBy AHU\_3 with its temperature, mode, device, and other points](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-trends-view.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=3e985e9898562bb68c2f408118767d71) Referenced device points appear as dashed lines on the trend chart, with the Referenced Devices panel on the right ## Supported references by canonical type The table below lists each canonical device type, its supported input references (relationships where the device is the target), and output references (relationships where the device is the source). **HVAC systems** | Device Type | isFedBy | feeds | isPartOf | hasPart | | - | - | - | - | - | | **chilledWaterSystem** | condenserWaterSystem, waterSystem | ahu, fcu, heatPump, waterSystem, radiantDevice | — | chiller, primaryPump, secondaryPump, pump, heatExchanger, waterTank | | **condenserWaterSystem** | waterSystem | chilledWaterSystem, waterSystem, radiantDevice | — | coolingTower, pump, heatExchanger | | **hotWaterSystem** | hotWaterSystem, waterSystem | ahu, cav, fcu, vav, uh, heatPump, snowMelt, waterSystem, hotWaterSystem, radiantDevice | — | primaryPump, secondaryPump, pump, heatExchanger, boiler, waterTank | | **waterSystem** | chilledWaterSystem, hotWaterSystem, waterSystem, condenserWaterSystem | ahu, cav, fcu, heatPump, radiantDevice, snowMelt, uh, vav | — | boiler, boosterPump, chiller, heatExchanger, pump, waterTank, primaryPump, secondaryPump | | **loopSystem** | — | secLoopSystem, ahu, cav, fcu, heatPump, radiantDevice, snowMelt, uh, vav | — | boiler, boosterPump, chiller, heatExchanger, pump, waterTank | | **secLoopSystem** | — | ahu, cav, fcu, heatPump, radiantDevice, snowMelt, uh, vav | — | heatExchanger, pump, waterTank | **HVAC equipment** | Device Type | isFedBy | feeds | isPartOf | hasPart | | - | - | - | - | - | | **ahu** | chilledWaterSystem, hotWaterSystem, waterSystem, ahu, heatExchanger, fan, secLoopSystem | vav, cav, fcu, ahu, uh, fan | — | fan | | **vav** | ahu, hotWaterSystem, waterSystem, fcu, secLoopSystem | — | — | — | | **cav** | ahu, fcu, hotWaterSystem, waterSystem, secLoopSystem | — | — | — | | **fcu** | chilledWaterSystem, hotWaterSystem, waterSystem, ahu, heatExchanger, fan, condenserWaterSystem, secLoopSystem | — | — | — | | **uh** | ahu, fcu, hotWaterSystem, waterSystem, secLoopSystem | — | — | — | | **fan** | ahu, fcu | ahu | ahu | — | | **outdoorVRF** | — | fcu, ahu, heatPump | — | — | **Components** | Device Type | isFedBy | feeds | isPartOf | hasPart | | - | - | - | - | - | | **boiler** | — | — | hotWaterSystem, waterSystem, loopSystem | — | | **chiller** | — | — | chilledWaterSystem, waterSystem, loopSystem | — | | **coolingTower** | — | — | condenserWaterSystem | fan | | **heatExchanger** | — | — | hotWaterSystem, condenserWaterSystem, chilledWaterSystem, waterSystem, loopSystem, secLoopSystem | — | | **heatPump** | chilledWaterSystem, condenserWaterSystem, hotWaterSystem, waterSystem, heatExchanger, secLoopSystem | — | — | — | | **pump** | — | — | hotWaterSystem, condenserWaterSystem, chilledWaterSystem, waterSystem, waterTank, snowMelt, loopSystem, secLoopSystem | — | | **boosterPump** | — | — | waterSystem, waterTank, loopSystem | — | | **waterTank** | — | — | waterSystem, chilledWaterSystem, hotWaterSystem, condenserWaterSystem, loopSystem, secLoopSystem | pump | | **snowMelt** | hotWaterSystem, waterSystem, secLoopSystem, loopSystem | — | — | pump | | **humidifier** | — | — | — | — | | **radiantDevice** | chilledWaterSystem, hotWaterSystem, waterSystem, heatExchanger, condenserWaterSystem, secLoopSystem | — | — | — | **Meters** | Device Type | measures | isMeasuredBy | hasSubmeter | isSubmeterOf | | - | - | - | - | - | | **electricMeter** | All canonical types except meters | — | electricMeter | electricMeter | | **energyMeter** | ahu, boiler, chiller, coolingTower, fcu, heatExchanger, heatPump, radiantDevice, snowMelt, uh, waterTank, loopSystem, secLoopSystem, chilledWaterSystem, hotWaterSystem, waterSystem | — | energyMeter | energyMeter | | **waterMeter** | boiler, chiller, coolingTower, heatExchanger, heatPump, radiantDevice, snowMelt, uh, waterTank, loopSystem, secLoopSystem, chilledWaterSystem, hotWaterSystem, waterSystem | — | waterMeter | waterMeter | | **gasMeter** | boiler, generator | — | gasMeter | gasMeter | | **steamMeter** | boiler | — | steamMeter | steamMeter | **Other device types** | Device Type | isFedBy | isMeasuredBy | | - | - | - | | **airCompressor** | — | electricMeter | | **airQuality** | — | electricMeter | | **av** | — | electricMeter | | **blinds** | — | electricMeter | | **bridge** | — | electricMeter | | **camera** | — | electricMeter | | **chargingStation** | — | electricMeter | | **computerDevice** | networkingDevice | electricMeter | | **doorLock** | — | electricMeter | | **electricityMonitoring** | — | electricMeter | | **elevator** | — | electricMeter | | **externalWeather** | — | electricMeter | | **fire** | — | electricMeter | | **generator** | — | electricMeter, gasMeter | | **leakDetection** | — | electricMeter, waterMeter | | **lighting** | — | electricMeter | | **networkingDevice** | — | electricMeter | | **presenceDetection** | — | electricMeter | | **sanitation** | — | electricMeter | | **smartLocker** | — | electricMeter | | **solarPanel** | — | electricMeter | | **switchGear** | — | electricMeter | | **thermohygrometer** | — | electricMeter | | **trafficCounter** | — | electricMeter | | **ups** | — | electricMeter | | **wasteCollector** | — | electricMeter | | **zone** | — | electricMeter | ## Next steps > [card] [Copied points](/products/kode-os/devices/copied-points) > > Mirror a point value into another device for independent use. > [card] [Virtual devices](/products/kode-os/devices/virtual-devices) > > Combine points from multiple sources into one logical device. # Device templates and modeling Source: https://docs.kodelabs.com/products/kode-os/devices/device-templates Create reusable device configurations with point mappings, tags, and normalization rules to standardize equipment across your portfolio. Device templates are reusable configurations that define the standard point structure, normalization rules, and tags for a specific type of equipment. Instead of manually configuring each device, you create a template once and apply it to all similar devices across your building or portfolio. ## How templates work A device template defines: * **Point mappings** that associate raw point names from the data source with standardized names in the Cloud BMS ontology (A standardized model of equipment types, points, and relationships used across Cloud BMS modules.) * **Normalization rules** that standardize units, naming conventions, and data types * **Tags** that follow the KODE ontology * **Entity type definitions** that categorize the device (for example, AHU, VAV, FCU) When you apply a template to a device, Cloud BMS maps the device's discovered points to the template's standardized definitions. This ensures consistent names and types across devices from different manufacturers. ## KODE ontology The KODE ontology follows the Google Digital Buildings ontology (Google DBO). Canonical types classify equipment. Ontology point fields classify the points on that equipment. Open the device type dropdown on Points Modeling to see the canonical types you can assign. The field panel lists the ontology point fields for the type you select. Search the [ontology field catalog](/products/kode-os/reference/ontology). See [Point modeling](#point-modeling) for how to map points. ## Point modeling Point modeling is the process of mapping raw point names to standardized ontology fields. You access Point Modeling from a device's detail page. The interface displays each point group with its raw name, mapped ontology field, point count, and template status. ![Points Modeling page for a VAV device showing point groups like DA\_Flow, DA\_Flow\_SP, and DA\_T with their mapped ontology fields, and a right panel listing compatible fields filtered by category](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-points-modeling-overview.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=79f002e58331e8df9d073269c8fc3fda) The Points Modeling page shows each point group with its field mapping, template status, and a panel of compatible ontology fields on the right Toggle **Group by Ontology** to organize point groups by their ontology categories (such as Discharge Airflow Control, Discharge Damper, or Discharge Temperature Control) instead of a flat list. ![Points Modeling page with Group by Ontology enabled, showing point groups organized under Discharge Airflow Control, Discharge Damper, and Discharge Temperature Control headings](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-group-by-ontology.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=5d7b0c28f94b27adc3cebf280507e8f3) Group by Ontology organizes point groups under their ontology category headings The standardized field format follows this structure: `[aggregator]_[descriptor]_[component]_[measurement descriptor]_[measurement]_[point type]` For example, a raw point named `SA-T` might map to `supply_air_temperature_sensor`. ### Entity types The Cloud BMS ontology defines four entity types: * **Canonical** entities are equipment templates (the primary device definitions) that contain mandatory field groups * **Abstract** entities compose canonical types and define reusable field groups * **General** entities apply to all canonical types and define common fields like running status and operation commands * **Virtual** entities represent calculated fields that do not correspond to physical sensors ## Create a device template **1. Navigate to point modeling** From the building view, go to **Devices** and select a device. Open the **Points Modeling** tab to see all discovered point groups. Use the **device type** dropdown at the top of the page to select the ontology device type (for example, `vav`, `ahu`, `boiler`). This determines which ontology fields are available for mapping. ![Device type dropdown expanded showing a searchable list of ontology types including ahu, airCompressor, airQuality, ats, av, blinds, boiler, boosterPump, bridge, camera, and cav](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-ontology-device-type.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=c5571c24aec90f8cdbe1517381701323) The device type dropdown lets you select the ontology type that defines available fields for this device **2. Map points to ontology fields** Select an unmapped point group to expand it. Cloud BMS shows the inline field selector where you can accept a suggested mapping or choose a different one. ![Inline field suggestion for DA\_T showing Discharge Air Temp with accept, cancel, and info icons, and templated status 0 of 1](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-inline-field-suggestion.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=f2831b49830a76f4e4f0b380be66001c) The inline field selector lets you accept, reject, or get more details on a suggested ontology mapping > [!NOTE] > > When selecting a point group, fields will be filtered based on: > > * **Point Kind** > * **Unit Category** (Number Points) You can also use the **field panel** on the right side of the page to search and filter for ontology fields. Use the search bar, unit category tags, and the **Compatible Only** checkbox to narrow results, then click **Apply** to assign a field. ![Field search panel filtered by Number and temperature showing Discharge Air Temp, Discharge Air Temp Setpt, Max Discharge Temp Setpt, and Min Discharge Temp Setpt with an Apply button](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-field-search-panel.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=1214fb082d23895ae70c70a041496afa) The field panel lets you search, filter by unit category, and apply an ontology field to the selected point group Use the **sort and view** menu in the field panel to control how fields are listed. Sort by **Most Used**, **Name: A to Z**, or **Name: Z to A**, and toggle between **Ungrouped** and **Ontology Groups** views. ![Field panel sort menu showing Sort by options for Most Used, Name A to Z, and Name Z to A, and View Options for Ungrouped and Ontology Groups](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-field-panel-sort-options.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=0a3ff7a56383748f32df5143dec91395) The field panel sort menu lets you order fields and switch between ungrouped and ontology-grouped views **3. Use AI-powered suggestions** Hover over a mapped point group to reveal the action toolbar. Click the **Suggest with AI** icon to get mapping recommendations. Cloud BMS offers two suggestion modes: * **Suggest with AI** recommends fields based on general AI knowledge and common naming patterns * **Historical** recommends fields based on how similar points were modeled in your organization ![Suggest with AI dropdown showing two options: Suggest with AI based on general AI knowledge and common patterns, and Historical based on how similar points were modeled in your organization](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-suggest-with-ai.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=a4e853a61c6ff3a172fac12cc6612d04) The Suggest with AI menu provides AI-based and historical mapping recommendations **4. Map enum points** For points with enum values (such as occupancy mode), Cloud BMS displays a mapping panel where you configure each enum state. Select the correct value for each state (for example, **Occupied**, **Unoccupied**, or **None**) and set writability per occupancy mode. Map enum values for Boolean and string points before you use devices in FDD or FTT. Unmapped enum values can block compatibility and command logic. ![Enum mapping panel for Occ\_Mode showing UnOccupied and Occupied Point Enum states with Occupied, Unoccupied, and None radio options, and Writability settings per mode with Suggest with AI and Save buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-enum-mapping.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=13a3fbc05a3440c2d57c19e1da06a002) The enum mapping panel lets you map each enum state and configure writability per mode **5. Review issue indicators** Before you save, review issue indicators on point groups: | Indicator | Meaning | | - | - | | **Duplicate Points** | Two or more points on a device share the same name | | **Multiple-Fields Applied** | Field, unit, display name, or precision differs within the group. Hover the `?` for details. | | `Missing Enums` | Boolean or string points are missing enum values | | `Not Mapped` | Enum values are not mapped to ontology fields | | `Partially Mapped` | Some enum values are mapped, but not all | | `Mapped` | All enum values are mapped | Resolve duplicates and complete enum mapping when devices must work with FDD or FTT. **6. Save the template** After mapping all points, save the configuration as a reusable template. Name the template to reflect the equipment type and configuration (for example, `AHU-Standard-4Pipe`). ## Edit field configurations When a point group is mapped, you can fine-tune its field settings. Hover over the point group and click the **edit** icon to open the field configuration panel. ![Edit field configs panel showing Original Name, Display Name with Prefix, Suffix, Name in Connector, and Data Interval tags, COV Tolerance set to 1, Default on Graph checkbox, Allow writability toggle, and Override checkbox](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-edit-field-configs.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=fe28faba27d789fd1e94e1df966a3cec) The field configuration panel lets you update display name, COV tolerance, graph defaults, and writability The configuration panel includes: | Setting | Description | | - | - | | **Original Name** | The raw point name from the data source | | **Display Name** | A human-readable label shown across the platform, with optional Prefix, Suffix, Name in Connector, and Data Interval tags | | **COV Tolerance** | How much a value must change before the KODE API stores a new reading. The threshold applies to KODE API sampling. The BACnet device keeps its own COV setting. | | **Default on Graph** | Whether this point appears on trend graphs by default | | **Allow writability** | Whether the point accepts write commands from users. When enabled, choose which actions the point accepts: `Override`, `Set`, and optionally `Set in Slot16`. Enable writability for command points that FTT workflows must write. | | **Override** | Whether the point accepts `Override` commands (typically priority 8) | | **Set** | Whether the point accepts `Set` commands (fallback or default value by default) | | **Set in Slot16** | Whether `Set` writes to priority 16 instead of the fallback or default (Niagara only) | ## Manage point groups The action toolbar on each point group provides controls for managing mappings. ### Multi select Click **Multi Select** to select multiple point groups at once. A bulk action toolbar appears at the bottom of the page with options to **Suggest with AI**, **Delete Groups**, **Clear Modeling**, **Map Enums**, or **Apply Field to Selected**. ![Points Modeling in Multi Select mode with two point groups checked, showing a bottom toolbar with Suggest with AI, Delete Groups, Clear Modeling, Map Enums, and Apply Field to Selected buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-multi-select.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=dc4c23580f6f6b515519e1cded8859f6) Multi Select mode lets you select multiple point groups and apply bulk actions from the bottom toolbar ### Individual actions > [tab] Delete points > > Click the **delete** icon to remove all points in the group from their corresponding devices. > > ![Delete Points confirmation dialog stating all points from the group will be deleted from the corresponding devices, with Cancel and Delete buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-delete-points.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=655b5fc8e842dda05406b9b4f8e15376) > > The delete confirmation prompts you before removing points from devices > [tab] Clear ontology field > > Click the **clear** icon to remove the ontology field mapping from the point group. Use this when a mapping is incorrect and needs to be reassigned. > > ![Clear Ontology field confirmation dialog warning that clearing the field may cause issues if the points are already used on FDD, FTT, or BBI, with Cancel and Clear buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-clear-ontology-field.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=cf7335098d84cef223ce17551a94e179) > > Clearing an ontology field warns about potential impacts on FDD, FTT, and BBI > > > [!WARNING] > > > > Clearing an ontology field may cause issues if the points are already used in FDD, FTT, or BBI applications. ## Apply a template to devices You can apply a template to one or multiple devices at a time. **1. Open batch update** Go to **Devices** and click **Batch Update Devices** in the upper right corner. **2. Select target devices** Filter and select the devices that match the template's equipment type. **3. Apply the template** Choose the template from the available list and apply it to the selected devices. Cloud BMS maps each device's discovered points to the template definitions. **4. Review results** Verify that points were mapped correctly. Devices with unmatched points are flagged for manual review. ## Review modeling After mapping points, use the **Review** menu to validate your modeling work. Click **Review** in the top toolbar to choose between two review modes. ![Review dropdown menu showing Review Fields and Review Entities options](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-review-menu.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=fac6414c9b9615d93a1a052352f9cb4a) The Review menu lets you review mapped fields or matched entities ### Review fields Select **Review Fields** to open the Review Modeling dialog. The left panel lists all mapped ontology fields with their point counts. Use the **Filter mode** dropdown to find devices that either contain all selected fields or are missing specific fields. ![Review Modeling dialog showing a list of ontology fields on the left with point counts, a Contains All filter mode dropdown, and a device table on the right showing VAV\_407 with 11 of 11 points on Floor 3](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-review-modeling.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=2dcaffb63cb36378f2aae082b37340e9) Review Modeling shows all mapped fields and the devices that match your filter criteria ### Run an ontology report Select **Review Entities** to run an ontology report that validates whether the mapped points correctly match entity definitions. ![Ontology Report for VAV showing 1 Matching and 0 Non-Matching, with VAV\_407 expanded to show entities including RM, ZTS, DAF, DTS, STS, OCCLGDAFC, and others](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-ontology-report.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=b14756ed7c40dd8fbf38c691b23f4e5b) The ontology report shows matching and non-matching devices with their associated entities The report displays a count of **Matching** and **Non-Matching** devices. Devices with the most missing fields or ontology errors appear first so you can address the largest gaps. Expand a device entry to see all associated entities. Each entity tag represents a recognized ontology match based on the mapped points. Use the lines-per-page menu to adjust the number of devices shown. > [!TIP] > > The ontology report validates that templates correctly describe device behavior. It verifies whether a point is a command or status, a number or enum, and whether the template is the right fit for the device's actual point structure. ## Import and export modeling The **more actions** menu (vertical three-dot icon) provides bulk operations for managing modeling data across devices. ![More actions menu showing Remove Ontology, Remove Devices, Import Modeling, and Export Modeling options](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-more-actions-menu.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=ce9aa31a00fc5672e7b1903f5bba42a1) The more actions menu provides options to remove ontology mappings, remove devices, and import or export modeling | Action | Description | | - | - | | **Remove Ontology** | Clears ontology field mappings from the selected devices | | **Remove Devices** | Removes the selected devices from the modeling view | | **Import Modeling** | Imports point mappings from a template file | | **Export Modeling** | Exports current point mappings to a template file | To import modeling, click **Import Modeling** to open the import dialog. Download the template file, fill in the ontology information, then upload it to apply the mappings. ![Import Modeling dialog showing three steps: Download Template, Add ontology information in provided template, and Upload template below and import your ontology, with a file upload area](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-import-modeling.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=63fa0f3c7d0bcea58c0aa0f9c2479d8d) The Import Modeling dialog walks you through downloading a template, adding ontology data, and uploading the completed file The downloaded template file contains one row per point with the following columns: | Column | Description | | - | - | | **Point Name** | The raw point name from the data source | | **Point Kind** | The data type of the point (for example, Number, Boolean) | | **Point Writable** | Whether the point accepts write commands | | **Point Unit** | The unit of measurement | | **Point Enum** | Enum values for the point, if applicable | | **Canonical Type** | The device's canonical entity type | | **Ontology Field** | The standardized ontology field name to map to | | **Ontology Display Name** | The human-readable display name | | **Ontology Precision** | The number of decimal places for display | | **Cov Ign Unit** | Whether to ignore the unit for change-of-value calculations | | **Ontology Cov Tolerance** | The change-of-value threshold | | **Ontology Default In Graph** | Whether the point appears on trend graphs by default | | **Ontology Prefix** | A prefix added to the display name | | **Ontology Suffix** | A suffix added to the display name | | **Ontology Write Map** | The write value mapping for enum points | | **Ontology Read Map** | The read value mapping for enum points | When you export modeling, the **Activity Log** in the bottom-right corner tracks the export progress. Once complete, click **Download .csv** to save the file. ![Activity Log showing Exporting Modeling as .xslx with Completed status and a Download .csv button](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-export-activity-log.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=fd1f06a190003933938a85db7a7b3af9) The Activity Log shows export status and provides a download link when the export completes ## Update a template When you modify a template, you can propagate changes to all devices that use it. Update the point mappings, save the template, and reapply it to the affected devices through batch update. ## Next steps > [card] [Batch update devices](/products/kode-os/devices/device-batch-update) > > Apply templates and make mass edits across multiple devices. > [card] [Points](/products/kode-os/points/points) > > Understand the data values that templates organize and standardize. # Devices Source: https://docs.kodelabs.com/products/kode-os/devices/devices View, filter, and manage physical and virtual equipment across your building in Cloud BMS. > [!NOTE] > > Devices is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its devices. Devices represent the physical and virtual equipment in your building. An air handling unit (AHU), variable air volume box (VAV), thermostat, meter, lighting controller, or any other piece of equipment connected to Cloud BMS appears as a device. Each device contains points (data values), belongs to a system, and is assigned to an area. [Manual meters](/products/kode-os/devices/manual-meters) are created as devices for offline utility readings. Register them from **Batch Update** > **Manual Meters**, then search for the meter on this list and open **Device Details** to manage reading logs and meter properties. Each meter stores **accumulator** and **differential** readings so you can log either the meter display value or a calculated consumption total. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR DS[Data Source] -- "discovers" --> DEV[Device] DEV -- "belongs to" --> SYS[System] DEV -- "assigned to" --> AREA[Area] DEV -- "contains" --> PTS[Points] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef peach stroke:#FBB35A,fill:#FFEFDB,color:#8F632D classDef rose stroke:#FF5978,fill:#FFDFE5,color:#8E2236 classDef green fill:#B0E4CC,color:#285A48,stroke:#285A48 class DS peach class DEV sky class SYS,AREA green class PTS rose ``` ## Navigate the devices list **1. Select your site** Click `Sites` in the left navigation bar and select the building you want to manage. **2. Open the devices module** Click `Devices` in the left sidebar menu. The devices list displays all equipment for the selected site. ![Devices list with columns for name, type, area, location, and points, with filter options at the top](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-list.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=3e39d1f6875e34bd77d977ec2315c0ae) The devices list shows each device's name, type, area, location, and point count Use the filters at the top of the devices list to narrow results by `Status`, `Type`, `Area`, `Data Sources`, `Origin Type`, or filter to devices with points. You can also search for a specific device by name using the search bar. Click `Export` to download the devices list, or click `Batch Update Devices` to make bulk changes across multiple devices. ## Device details Click any device name in the list to open its detail page. The device header displays the device name and its area assignment (for example, `Floor 3`) next to it. Click the area link to navigate directly to the floor plan where the device is located. The detail page provides four tabs: `Trends`, `Graphic`, `FTT`, and `Device Details`. ### Trends tab The `Trends` tab displays historical time-series data for the device's points. A summary bar at the top shows active `Events`, recent `Faults`, `Schedule` status, `Referenced Devices`, and current `Weather` conditions for the site. ### View faults from trends Review fault history in device context without leaving the **Trends** tab. The summary bar links faults to the routines and point data you use for investigation. Click **Faults** in the summary bar to open the **FDD Faults** panel on the right. ![VAV\_101 Trends tab with Faults summary showing 1 recent fault and FDD Faults panel open on the right for Temperature Greater than Setpoint while Occupied](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-trends-fdd-faults.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=c48602adc4b818b802df1f0db6ef328a) FDD Faults panel on the Trends tab The panel shows faults for this device in the default **Recent** view, which covers the **last two weeks**. Each entry includes: | Field | Description | | - | - | | **Routine name** | The FDD routine that generated the fault | | **Status** | Current fault status (for example, Open or In Progress) | | **Watchers** | Users monitoring the fault | | **Duration** | How long the fault has been active | | **Last comment** | Most recent note from the fault activity log | | **Time in Fault per Day** | Visual chart of daily fault duration | Select a fault to open the full [fault report](/products/fdd/faults#fault-report). The report trends the data points that triggered the fault so you can analyze routines and logic alongside live device data. ### Date range for device faults Use the date picker in the **FDD Faults** panel to change the time window: | Selection | Behavior | | - | - | | **Default (Recent)** | Last two weeks | | **More than two weeks** | Full fault history for the selected range | | **Less than two weeks** | Aligns to the end date plus the preceding two weeks | You can view faults older than two weeks by choosing a wider preset or a custom date range. ### Navigate between faults and device details Fault records and device pages link to each other in both directions: * **From Trends** — Open **Faults** in the summary bar, then select a fault to open its report with triggering points trended automatically. * **From a fault report** — Click the **device name** under the fault title to open that device's **Device Details** page. * **From Device Details** — The **Faults** card in the top section shows the same recent fault history for the device. Expand the card to review the full list or open an individual fault. See [Faults](/products/fdd/faults) for list views, filters, bulk actions, and watcher management. ### View referenced points on trends You can overlay referenced device points directly on a device's **Trends** tab. Click **Referenced Devices** in the device header to open the referenced devices panel on the right. The panel lists all references grouped by type (for example, `isFedBy`), along with the referenced device's points. Select a referenced device's points to overlay them on the trend charts. Referenced point data appears as **dashed lines** on the chart, making it easy to distinguish from the device's own point data. For how device references are defined and managed, see [device referencing](/products/kode-os/devices/device-referencing). ![FCU208 Trends tab showing Temperature, Mode, and Status charts with AHU\_3 Supply Air Temp Setpt displayed as a dashed line, and the Referenced Devices panel on the right showing isFedBy AHU\_3 with its temperature, mode, device, and other points](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-referencing-trends-view.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=3e985e9898562bb68c2f408118767d71) Referenced device points appear as dashed lines on the trend chart, with the Referenced Devices panel on the right The left panel lists points grouped by category (Temperature, Flowrate, Mode, Damper, and others) with live values. Each point has a checkbox. Select or deselect individual points to enable or disable them on the charts. Click `Clear Selection` at the top of the panel to deselect all points at once. ![Trends tab in Split Charts view showing Temperature and Flowrate charts with point selection panel on the left](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-trends-split-charts.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=cb035c9d92c510220e830854ee8054d8) The Trends tab shows point data in split chart format grouped by category Use the toolbar to switch between three display modes: * **Split Charts** displays a separate chart for each point category * **Combined** overlays all selected points on a single chart * **Table** shows raw data values in a tabular format with timestamps ![Trends Table view showing date, time, and point values in rows with sortable columns](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-trends-table.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=2034ff9ac477ec1012a2d678aa7b00c9) The Table view shows timestamped values for each selected point Use the date range selector to choose a time period and the granularity dropdown to set the data resolution. ![Granularity dropdown showing options for 1 minute, 2 minutes, 5 minutes, 1 hour, 3 Hours, 1 Day, and Raw](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-trends-granularity.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=5e79e0431ef874abb905e3f8912fa5bd) Available granularity options include `1 minute`, `2 minutes`, `5 minutes`, `1 hour`, `3 Hours`, `1 Day`, and `Raw`. Select `Raw` to see every collected data point without aggregation. Click the three-dot menu to access `Trends Settings` or `Export Point Timeseries`. ![Trends Settings panel showing aggregate function dropdown per point and Y-axis left or right assignment](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-trends-settings.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=77d4d53ee42ee9170057028cd8837700) Trends Settings lets you configure aggregate functions and Y-axis assignments per point In `Trends Settings`, you can set the aggregate function (`AVERAGE`, `MAX`, `MIN`, `SUM`) for each point and assign points to the left or right Y-axis. Aggregation is only available when the granularity is set to something other than `Raw`. > [!TIP] > > Drag on a chart or the zoom bar below it to zoom into a specific time range. Double-click the chart to reset the zoom. Click the help icon in the upper-right corner for a quick reference. You can also export individual charts as images or PDFs. Click the download icon in the upper-right corner of any chart to choose `Export as image` or `Export as PDF`. ![Chart export menu showing Export as image and Export as PDF options](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-chart-export.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=41c641fb2461fb2094852d0d50bf0565) ### Graphic tab The `Graphic` tab displays a visual representation of the device with live point data overlaid on the graphic. Hover over elements to see current values. ![3D graphic of a VAV unit showing live point data including discharge air temp, damper percentage, and flow values](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-graphic.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=fd02180f00a533fb2ef785346b760a7e) The Graphic tab shows a 3D device model with live point values ### FTT tab The `FTT` ([Functional Testing Tool](/products/ftt/overview)) tab lets you run and review automated equipment tests. The left panel lists previous test reports with their status. Click `+ Start New Test` to initiate a new test workflow. See [run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device) for step-by-step instructions. ![FTT tab showing archived test reports on the left and a test detail view with building, device, workflow, status, duration, and a step-by-step action log](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-ftt-tab.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=8fb99639c822887fd7a2046db82db22d) The FTT tab shows test reports with details, workflow steps, and timestamped actions Select a report to view its details. See [test result reports](/products/ftt/test-results#test-result-report) for a full breakdown of each section: * **Details** section shows the building, device name, device type, area, initiated by, workflow name, start and end time, status, and duration * **Test log** displays each step of the workflow with the action taken and the log time * Click `View Parameters` to see the test configuration, or click `Archive` to archive a completed test ### Device Details tab The `Device Details` tab displays the device's metadata and configuration properties. The **Faults** card at the top shows faults from the last two weeks for this device. Expand the card to review the full list or open an individual fault report. You can also open faults from the [Trends](#view-faults-from-trends) summary bar. ![Device Details tab showing data source, canonical type, device type, location, device class, site level, points count, and attachments section](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-device-details.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=0b2fa479aec6c5b98fdc6f03c4409010) The Device Details tab shows device metadata, location, and attachments Use the **Device Details** section to view: * **Data Source** that discovered the device * **Canonical Type** and **Type** * **Location** and **Device Class** * **Tenant** and **Site Level** assignments * **Points** count with a link to `Edit Points` * **Located in** breadcrumb showing the building and floor Click `Edit Device` to modify device properties. You can enter and save new **Device Class**, **Tenant**, and **Zone** values directly from this form. Click `Go to Modeling` next to the canonical type to open the ontology modeling view. The **Referenced Devices** section shows all [device references](/products/kode-os/devices/device-referencing) for this device, listing each referenced device's name, reference type (for example, `isFedBy`), and device type. Click **+ Add** to create a new reference or use the delete icon to remove an existing one. The **Attachments & Notes** section at the bottom stores photos, documents, and notes associated with the device. ### Device status indicators Devices display status indicators that reflect their operational state: * **Online** (green) means the device is communicating and data is current * **Offline** (grey) means communication with the device has been lost * **In alarm** (red) means an active fault or alert condition exists on the device ## Weather device Buildings with Cloud BMS enabled include a KODE-managed [Weather device](/products/kode-os/devices/weather). Outdoor conditions appear as standard points for Trends, dashboards, and FDD. Open `Devices`, search for `Weather`, then see [Weather device](/products/kode-os/devices/weather) for points, platform protection, and recommended monitoring rules. ## View and edit points Click `Edit Points` on the `Device Details` tab or navigate directly to the points view for a device. The points list displays each point's name, current value, status, point type, and tags. ![Points list for VAV\_303 showing 11 points with a detail editor panel for Discharge Air Temp on the right side](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-points-list.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=57e5860658e98978a3e604dbc035037d) The points list shows live values and the point editor panel on the right Click any point to open its editor panel on the right side. The editor lets you configure: * **Display Name** and **Name** * **Unit** of measurement * **Tags** * **Min Value** and **Max Value** range * **COV Tolerance**, which sets how much a value must change before the KODE API stores a new reading. The BACnet device keeps its own COV setting. * **Precision** (decimal places) * **Metadata** key-value pairs * **Allow writability** toggle with `Override`, `Set`, and `Set in Slot16 (Niagara only)` options. `Override` writes to a priority-array slot. `Set` changes the fallback or default value unless `Set in Slot16` is enabled, which routes `Set` to priority 16 instead. * **Default in graph** toggle ### Point details and activity In the Trends tab left panel, hover over a point to reveal the info and edit icons. Click the info icon to open the `Point Details` dialog, or click the edit icon to open `Edit Point`. The `Point Details` dialog has three tabs: > [tab] Details > > Displays the point's technical metadata including `Data Source`, `Location` (full path in the external system), `Id`, `Field` (ontology field), `Name`, `Point Type`, `Status`, and `Unit`. > > ![Point Details dialog showing data source, location path, ID, field, name, point type, status, and unit](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-point-details-dialog.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=13a909baf038484e63e146b32d8f15e2) > > The Details tab shows the point's source system path and ontology field mapping > > Click `Test Connection` to verify that Cloud BMS can read the point from the external system. > [tab] Activity > > Shows a log of actions performed on the point, including the date, user, and reason for each change. > > ![Point Activity tab showing a single entry dated Oct 1 2025 with reason Routine Maintenance](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-point-activity.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=2e64d864b253f754d45e17a50a5f5f88) > > The Activity tab shows a history of changes to the point > [tab] FDD > > Displays any active alarms for the selected point. ## Command and control equipment You can send commands to writable points directly from the device details page or from a floor plan. The command dialog works the same across integrations. BACnet devices, API thermostats, and other connectors all use this write-back flow, even when the underlying protocol is not BACnet. For the full procedure, action mappings, and floor plan access paths, see [command and control points](/products/kode-os/points/commanding-points). **1. Locate a writable point** On the device details page, hover over a point value. Writable points display a blue box indicating they accept commands. **2. Open the write dialog** Click the writable point to open the command dialog. **3. Configure the command** Set the command parameters in the dialog. The left side shows the point name and current value. The right side contains the action fields. ![Command dialog for Discharge Air Temp showing Override action, value field, duration, reason, permanent checkbox, and current levels including priority 8 and fallback](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-command-dialog.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=614858cf3b4bc6e1aef9603ebb3812bf) The command dialog shows action, value, duration, and reason fields with current levels at the bottom **Command parameters** | Field | Description | | - | - | | `Priority` | The command action to apply (`Override`, `Set`, `Auto`, or `Release`). See the action mappings below. | | `Value` | The value to write (for example, `62.6 °F` for a temperature setpoint). Use the `+` and `-` buttons to adjust. | | `Duration` | How long the command should remain active before auto-reverting (hours and minutes) | | `Reason` | A predefined reason from the dropdown | | `Permanent` | Check this to make the command persist without auto-reverting | | `Specific Reason` | A free-text note explaining why this change is being made | The bottom of the dialog displays the current levels and their values. Click `Activity Log` in the upper-right corner to view the full command history for this point. **4. Submit the command** Click `Save Changes` to send the command to the device. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ## Export point timeseries To export historical data for a device's points, click the three-dot menu on the Trends tab and select `Export Point Timeseries`. A two-step wizard opens. **1. Select points** Choose which points to include in the export. Use the filters at the top (`Field`, `Kind`, `Device Type`, `Ontology Type`, `Area`, `Data Sources`, `Writability`) to narrow the list, or search by name. Select individual points or use the checkbox in the header to select all. ![Export Point Timeseries step 1 showing a list of points with checkboxes, values, fields, and device assignments](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-export-select-points.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=23e49ce3b6e6286e470607a60de6123e) Step 1 lets you choose which points to include in the export Click `Next` when your selection is complete. **2. Configure export settings** Choose the export format, time range, granularity, and columns. ![Export settings showing Raw List and Pivoted format options, time range selector, granularity dropdown, and columns picker](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-export-settings.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=67607aea8d1560b5c10c183e2d55eece) Step 2 lets you configure format, time range, and granularity * **Raw List** exports all points as rows sorted by point name * **Pivoted** exports points as columns with time as rows * **Timerange** sets the date range for the export (for example, `Last 7 Days`) * **Granularity** sets the data resolution (`Raw`, `1 minute`, `5 minutes`, `1 hour`, and others) * **Columns** selects which fields to include in the export (Date Time, Point ID, Point Kind, Display Name, and others) Click `Export` to download the file. ## Next steps > [card] [Device templates](/products/kode-os/devices/device-templates) > > Create reusable configurations and apply them across similar devices. > [card] [Batch update devices](/products/kode-os/devices/device-batch-update) > > Make mass edits to device metadata, area assignments, and templates. > [card] [Virtual devices](/products/kode-os/devices/virtual-devices) > > Build software-defined devices for calculated values and logical groupings. > [card] [Device referencing](/products/kode-os/devices/device-referencing) > > Link points and devices for cross-referencing across systems. # Create and manage manual meters Source: https://docs.kodelabs.com/products/kode-os/devices/manual-meters Register offline utility meters, log readings, and manage meter devices in Cloud BMS for trending and analytics > [!NOTE] > > Manual meters is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map), then open **Devices** > **Batch Update** > **Manual Meters**. Manual meters bridge automated smart meters and unconnected utility meters that still rely on spreadsheets or paper logs. You create a structured device for offline utility meters, then log readings on the web or mobile. Cloud BMS applies conversion factors so manual data can power dashboards, historical trending, billing workflows, and API access like connected device data. Each manual meter is stored as a **device** with two points by default: an **accumulator** point for the value on the meter display, and a **differential** point for calculated consumption over a period (for example, a day, week, or month). When you add a reading, you choose which type to store. Logged values appear in **Reading Logs** as a table and in **Trends** as time-series data. After you create a meter, open it from the **Manual Meters** list or search for it on the main [Devices](/products/kode-os/devices/devices) list. ## Supported meter types You can create these manual meter types: * Electric Meter * Energy Meter * Water Meter * Steam Meter * Gas Meter ## Navigate to Manual Meters **1. Select your site** Click **Sites** in the left navigation bar and select the building you want to manage. **2. Open Manual Meters** Click **Devices** in the building sidebar, then select **Batch Update**. Select **Manual Meters** in the batch update menu. ![Manual Meters page with search bar, Filters and Add Meter buttons, and table columns for Name, Location, Area, Connector, Meter Type, Storage Unit, Conversion Factor, and Serial Number](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-list.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=7e141dd45e68787dbf31cb01aa16f954) The Manual Meters list shows meter metadata columns, search, filters, and actions to add meters or readings Use **Search for meters** to find a meter by name. Click **Filters** in the header to narrow the list by connector, meter type, area, or other fields. ## Create manual meters Manual meters are created in a table-based dialog so you can add one or many meters in a single save. **1. Open Add Meter** On the **Manual Meters** page, click **+ Add Meter**. **2. Add rows** In the **Add Meters** dialog, each row is one meter. Click **+ Add Row** to add more rows. Use the row actions to duplicate or delete a row. **3. Enter required fields** Fill in these columns for each row: | Column | Description | | - | - | | **Meter Name** | Display name for the meter device | | **Connector** | Data connector assigned to the meter device (for example, `N4` or `jace`) | | **Meter Type** | Canonical type (for example, `energyMeter` or `electricMeter`) | | **Unit of Measurement** | Storage unit for readings (for example, `kWh` or `BTU`) | | **Conversion Factor** | Multiplier applied to native readings (defaults to `1.0`). Stored value = native value × conversion factor | **4. Save meters** Click **Add Meters** to create the devices. > [!NOTE] > > The **Connector** field assigns the meter to a data source in your site. It does not change how readings are captured or stored. > [!TIP] > > Use **Conversion Factor** when the physical meter displays a different unit than you want to store. For example, enter a factor that converts watt-hours (`Wh`) on the dial to kilowatt-hours (`kWh`) in storage. ![Add Meters modal with table rows for Meter Name, Location, Area, Connector, Meter Type, Unit of Measurement, and Conversion Factor, plus Add Metadata and Add Row buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-add-meters.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=530223d9bb664b668e60010377b3c7fa) The Add Meters dialog supports multiple rows with required meter fields and optional metadata columns ### Add optional metadata columns Click **+ Add Metadata** to show extra columns in the table before you save. ![Add Metadata dropdown with General Information fields Location and Area checked, and Details fields such as Serial Number, Identifier, Description, Vendor, Manufacturer, and Model](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-add-metadata.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=11ba30c051cf5a7b3077504406d40403) Add Metadata lists general and detail fields you can expose as columns in the Add Meters table **1. Select metadata fields** In **Add Metadata**, select the fields you want as columns. Examples include **Location**, **Area**, **Serial Number**, **Identifier**, **Description**, **Vendor**, **Manufacturer**, and **Model**. **2. Enter values and save** Fill in the new columns for each row, then click **Add Meters**. > [!TIP] > > **Area** captures the meter's space placement when your site uses areas. **Location** is an additional contextual field depending on how your organization labels floors or zones. ## Add readings in batch Batch entry adds one reading per selected meter in a single save. **1. Select meters** On the **Manual Meters** page, select the checkboxes for the meters you want to update. **2. Open Add Reading** Click **Add Reading** in the bottom-right corner. **3. Enter reading data** In the **Add Readings** dialog, set **Reading type**, **Date & Time**, and **Value** for each selected meter. Choose **Accumulator** for the value on the meter display, or **Differential** for calculated consumption over a period. Review **Value Preview** to confirm the stored value (native value × conversion factor). **4. Add attachments or notes (optional)** Use **Attachments** (**+ Add**) or the **Notes** column when you need supporting files or context. **5. Save readings** Click **Add Readings**. ![Manual Meters list with Meter 3 and Meter 4 selected and Add Reading button visible in the bottom right](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-list-selected.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=87d80ef9b29a1d7d38d5e18c0a1e84c9) Select multiple meters on the Manual Meters list, then use Add Reading for batch entry ![Add Readings modal with rows for Meter 4 and Meter 3 showing Date and Time, Value, Value Preview, Attachments, and Notes columns](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-add-readings.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=aad1f2e778b2d969f860342d86ef0737) The Add Readings dialog collects date, value, preview, attachments, and notes per meter > [!WARNING] > > If the entered value is lower than the previous reading for that meter, the **Value Preview** cell shows a warning (for example, *Value is less than the previous one: 320 kWh, please verify.*). Confirm the reading on the physical meter before you save. ![Add Readings row with Value Preview showing orange highlight and tooltip stating value is less than the previous one 320 kWh please verify](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-reading-validation.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=0e705e071ae67fd9a1bd75641940a267) A warning icon appears when a new value is less than the prior reading for the same meter ## Accumulator and differential readings Every manual meter has both point types. KODE OS adds differential points to existing meters and creates both points for new meters. The reading workflow stays the same except for the type you select. | Reading type | What you enter | Stored on | | - | - | - | | **Accumulator** | The value shown on the meter display | Accumulator point | | **Differential** | Calculated consumption for a period (daily, weekly, or monthly) | Differential point | Use accumulator when you copy the dial or register. Use differential when you already calculated usage for a period and want to store that total instead. ## Reading rules and validation These rules apply when you add readings on the web or mobile. ### Date and order * Each reading's date and time must be **later than** the last saved reading for that meter and reading type. * You can add historical readings up to **six months** before the meter was created. * When backfilling history, enter readings in chronological order. Start with the earliest month and work forward. ### Values and corrections * Enter the **native value** for the reading type you selected. **Value Preview** shows the stored result (native value × conversion factor). * Accumulator readings should increase over time. If a new accumulator value is lower than the previous accumulator reading, verify the meter before you save. You can still proceed after confirmation. * You can delete only the **most recent** reading to correct a mistake. Older readings cannot be removed. * There is no limit on how many readings you can add per month. ### Attachments and notes Add photos, files, or notes with a reading to support verification and audit workflows. On mobile, you can capture a photo as an attachment in the field. ## Manage a meter from Devices After creation, each manual meter appears as a device on the main **Devices** list. **1. Open Devices** Click **Devices** in the building sidebar (not only **Manual Meters**). **2. Find the meter** Use the search bar or filters to find the manual meter by name. Open the device by clicking its name in the list. **3. Open Device Details** On the device page, select the **Device Details** tab (alongside **Trends** and other tabs). ### Reading logs The **Reading Logs** section at the top of **Device Details** lists historical entries. ![Manual Meter 2 device page on Device Details tab with Reading Logs table showing Reading Date, Value, and Attachments columns and Add Reading Log button](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-reading-logs.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=f8eeee1d033f4b8df26b613247cf4f72) Device Details shows Reading Logs with dates, values, attachments, and Add Reading Log **1. Add a single reading** Click **+ Add Reading Log**. Select **Reading type** (**Accumulator** or **Differential**), then enter **Value** and **Date & time**. Optionally add attachments or notes, then save. **2. Review log details** Expand a row to see **Native Reading**, **Conversion Factor**, **User**, **Notes**, and attachment previews. ![Expanded reading log row showing Native Reading 200 kWh, Billing Multiplier 1.0, User Granit Gojani, and Notes field](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-reading-logs-expanded.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=f73c43ef61536adb2f1851179c4786fe) Expand a reading log row to view native value, multiplier, user, and notes To correct a mistake, use the delete action on the **most recent** reading only. See [Reading rules and validation](#reading-rules-and-validation) for date, order, and deletion limits. ### Edit or delete the meter Scroll past **Reading Logs** to the **Device Details** section at the bottom of the tab. ![Device Details section showing general device fields, Meter Metadata with Source Form Manual and Conversion Factor, and Edit Device and delete buttons in the header](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-manual-meters-device-details.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=9ea07012587a270b769499d8396f22c5) The Device Details section provides Edit Device and delete actions for the meter * Click **Edit Device** to change name, location, connector, meter type, conversion factor, serial number, and other metadata. * Click the **delete** button to remove the meter from the site. Confirm when prompted. In **Meter Metadata**, **Source Form** shows **Manual** for meters created through this workflow. ## Related topics > [card] [Devices](/products/kode-os/devices/devices) > > Browse, filter, and manage all building devices including manual meters. > [card] [Trends](/products/kode-os/trends) > > Chart manual meter point history alongside other building data. > [card] [Manual meters on mobile](/products/mobile-app/building/manual-meters) > > Create meters and log readings from the Cloud BMS mobile app. # Virtual devices Source: https://docs.kodelabs.com/products/kode-os/devices/virtual-devices Split systems into logical virtual devices, map points from pseudo devices, and manage virtual equipment alongside physical devices. Virtual devices let you separate grouped systems and devices so you can use them more clearly in operations and analytics. You can split one physical device into multiple virtual devices, group points by function, or build logical views without adding hardware. You configure virtual devices on `Setup Virtual Devices`. Pseudo devices (A source device whose points you redistribute into one or more virtual devices.) are sources whose points you reuse; virtual devices (A logical device you build by assigning points from one or more pseudo devices.) are the destinations you build. Assign points by dragging them from a pseudo device into a virtual device configuration. You can also drag selected point groups into **Create New Device** to create a virtual device named from the group. ## Navigate to Setup Virtual Devices Open `Devices` at your site or building. Click `Batch Update Devices` in the upper right, then choose `Virtual Devices` in the left menu to open `Setup Virtual Devices`. From the main `Devices` list you can also open `Batch Update Devices` for bulk work, or use the row menu on a device for `Edit`, `Export Point Timeseries`, or `Delete`. ![Devices list with filters for Type and With points, Export and Batch Update Devices buttons, and a row menu showing Edit, Export Point Timeseries, and Delete](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-devices-list.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=fefca04bd3ee6643ab57366f4ef3f35c) From Devices, open Batch Update Devices to reach Setup Virtual Devices and related batch workflows ## Pseudo devices A pseudo device is a source device whose points you can assign to virtual devices. Only devices marked as pseudo appear in the `Pseudo Devices` list on `Setup Virtual Devices`. ### Mark a device as pseudo Use either path: * **Device list:** Go to `Devices`. Hover the row for the device you want. On the right side of the row, click the three-dot menu (it appears when you hover), then choose `Edit`. Set `Is Pseudo Device` to `True`, then click `Save`. * **Batch update:** Go to `Devices` > `Batch Update Devices`, select the devices, open the **Properties** panel, set `Is Pseudo Device` to `True`, and apply. ![Edit Device form showing Device Location, Device Class, Tenant, Zone, Type VAV, Area, Is Pseudo Device set to True, and Site Level toggle](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-edit-pseudo.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=b494557e66d737d8982f22271e36bd5c) Set Is Pseudo Device to True when you want the device to act as a point source for virtual devices After you mark a device as pseudo, it leaves the main Devices list. To see it again, unset the pseudo flag or open **More** and select `Show Pseudo devices`. You can delete a pseudo device after moving its points to virtual devices. KODE OS returns the associated points to their original folders when it removes the pseudo device. ## Page layout The `Setup Virtual Devices` page is split into two sides: **Left — Pseudo devices** * Lists pseudo devices with point counts. * Use search, sort, and filters (for example devices with or without points). * Select a device to load its points in the adjacent panel. Each point shows name, path (for example Niagara slot path), and live value. **Right — Virtual devices** * Lists virtual devices you created. * Select one to view or edit its assigned points. Points are grouped by the pseudo device they came from where applicable. * Filter and sort by name, created date, type, area, point count, and related chips (for example `Created from {pseudoDeviceName}` after you select a pseudo device). Use `Locate Device` on a virtual device when you need to highlight its source pseudo device on the left. ## Create virtual devices Click `+ Create new device` in the `Virtual Devices` column. ### Create new device dialog **Bulk rows:** In `Add multiple`, enter a base `Name`, set `From` and `To` for the numeric range, then click `Add`. Names are generated for each row (for example `Meeting_Room 1` through `Meeting_Room 15`). You can then set `Location`, `Type`, `Area`, and `Tags` per row. Use the column header dropdowns on `Type` or `Area` to apply the same value to many rows at once. **Single rows:** Click `+ Add single` to add one row and fill all fields manually. Use `Find & Replace` at the bottom of the dialog to rename or adjust values in bulk. When the table looks correct, click `Create`. After creation, the new virtual device appears in the `Virtual Devices` list and you can select it to map points. ![Create new device modal with Add multiple name prefix and From and To fields, table of VAV devices with Type and Area dropdowns, Find and Replace, Cancel, and Create buttons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-create-modal.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=07cd0d483cf198e429bf8497a81eadf6) Create one or many virtual devices with type, location, and area before clicking Create ### Edit or delete a virtual device In the `Virtual Devices` column on Setup Virtual Devices, hover the row for the virtual device you want to change. Click the three-dot menu on the right side of the row (it appears when you hover), then choose an option: * `View Device Details` — Opens the device’s full page (same as opening it from the main `Devices` list). * `Edit Device` — Opens the edit dialog to change properties such as name, location, type, and area. * `Delete` — Removes the virtual device and returns its associated points to their original folders. Confirm when prompted. ![Virtual Devices list with VAV\_4 row selected and three-dot menu open showing View Device Details, Edit Device, and Delete](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-row-menu.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=cb8c69b478b1cd23c811dc0a915ff6a7) Use the row menu on a virtual device for View Device Details, Edit Device, or Delete ## Map points to virtual devices The workspace shows pseudo devices, their points, the virtual device list, and the configuration panel for the selected virtual device. ![Setup Virtual Devices with Pseudo Devices list, points for VAV\_101, Virtual Devices list with Create new device, and FCU208 mapping panel showing dragged points and values](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-setup-overview.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=5fcd6f3752b51b1319d32bf99f7867aa) Setup Virtual Devices shows pseudo devices, their points, virtual devices, and the mapping panel ### Drag and drop Select a pseudo device on the left and a virtual device on the right. Drag points from the middle column into the configuration panel. When the virtual device is empty, you see `Drag and drop points from pseudo here`. While dragging, the target may show a prompt such as `Drop points to {device}`. ![Setup Virtual Devices with VAV\_101 pseudo points, VAV\_4 selected in Virtual Devices, and empty folder message to drag points from Pseudo Devices](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-empty-drop-zone.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=228a0d56fc0c9512d4cda45414cb488a) An empty virtual device shows instructions to drag points from pseudo devices ![Setup Virtual Devices showing Ramp1 point being dragged from VAV\_101 points list into the Drop points to VAV\_4 zone](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-drag-drop.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=34051582cdf72f31f407cc17dcf26501) Drag a point from the pseudo device list into the virtual device drop zone ### Review and remove points Each mapped point shows type, name, path, value, and an `X` icon. Click `X` to remove that point from the virtual device immediately. No confirmation dialog appears. The point becomes available again on the source pseudo device if you want to map it elsewhere. ![Virtual device configuration panel with GreaterThan, NumericSwitch, NumericSwitch1, and Ramp1 mapped with values and remove icons](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-virtual-mapped-points.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=8545167bb9876993bec25d05017e487e) Mapped points list shows each point with value and an option to remove it from the virtual device ## Use virtual devices elsewhere Virtual devices you create behave like other devices where your permissions allow: `Trends`, `Device Details`, graphics, and schedules. > [!NOTE] > > Pseudo devices supply points; virtual devices are the grouped or split views you use for day-to-day monitoring and control. ## Next steps > [card] [Devices](/products/kode-os/devices/devices) > > Open any device for details, trends, and batch actions from the list. > [card] [Batch update devices](/products/kode-os/devices/device-batch-update) > > Set Is Pseudo Device and other properties across many devices at once. # Weather device Source: https://docs.kodelabs.com/products/kode-os/devices/weather Use the KODE-managed Weather device to compare outdoor conditions with equipment data in Trends, dashboards, and FDD. Buildings with Cloud BMS enabled receive a **Weather** device that KODE manages. Outdoor conditions appear as standard points next to equipment data. You do not connect a weather API key or install weather hardware for this feed. The device uses the `externalWeather` canonical type. Temperature points follow the building temperature unit. > [!NOTE] > > Weather is a building-level device. Select a building from the [sites list](/products/kode-os/sites-and-map), then open [Devices](/products/kode-os/devices/devices). ## Open the Weather device **1. Open Devices** Select your building, then click `Devices` in the left sidebar. **2. Find Weather** Search for `Weather` and open the device. The device name is **Weather**. **3. Review points on Trends** On the `Trends` tab, select weather points in the left panel. Use `Split Charts`, `Combined`, or `Table` the same way as for any other device. ![Weather device Trends tab showing point categories on the left including Outside Air Temp and Outside Air Pressure checked, Split Charts view for the last 2 days at Raw granularity, and charts for Outside Air Temp and Outside Air Pressure](https://mintcdn.com/kodelabs/c-bfVz_aNeAM7gh-/images/kode-os/devices/kode-os-devices-weather-trends.png?fit=max\&auto=format\&n=c-bfVz_aNeAM7gh-\&q=85\&s=06f6efa083458160afb03d3949e490c4) Weather device Trends with Outside Air Temp and Outside Air Pressure selected The summary bar on the Trends tab also shows current site weather next to Events, Schedule, and Referenced Devices. ## Weather points Points are grouped by ontology category on Trends, the same as other devices. | Point (display name) | Category | What it provides | | - | - | - | | Outside Air Temp | Temperature | Outdoor dry-bulb temperature | | Apparent Outside Air Temp Sensor | Temperature | Feels-like temperature | | Outside Air Dewpoint | Temperature | Outdoor dew point | | Outside Air Humid | Humidity | Outdoor relative humidity | | Outside Air Pressure | Pressure | Atmospheric pressure | | Wind Speed | Linear velocity | Wind speed | | Max Wind Speed Sensor | Linear velocity | Peak gust speed | | Wind Angle | Angle | Wind direction | | Precipitation Level Sensor | Level | Precipitation amount | | Current Weather Code | Label | WMO condition label (for example, Clear sky) | | Outside Air Enthalpy | Specific enthalpy | Calculated from temperature and humidity | KODE collects values about every 30 minutes. When historical collection is enabled for the deployment, a background job can backfill about three years of hourly history. Forecast data is stored for internal features and is not shown on the device. ## Platform-managed feed KODE creates the **KODE Weather** datasource, the Weather device, and its points for buildings with Cloud BMS enabled. The same entities are created when a new building is added or Cloud BMS is activated. KODE protects these entities from deletion, duplication, and structural edits that would break the feed. The KODE Weather datasource does not appear in the API catalog because customers do not set it up. ## Use weather with equipment data Weather points work in the same places as other device points: * **[Trends](/products/kode-os/trends)** — overlay Weather with equipment readings on one chart * **Device Trends** — compare Weather to a local outdoor sensor from another device using [referenced devices](/products/kode-os/devices/device-referencing) * **Building BI** — add weather points to dashboards like any other timeseries field * **[FDD](/products/fdd/routines)** — configure routines that reference `externalWeather` when the building has the required equipment points and thresholds > [!TIP] > > For a comfort complaint or economizer review, plot `Outside Air Temp` next to the equipment outdoor air temperature or discharge air temperature over the same period. ## Recommended monitoring rules Weather-aware FDD rules are available in the [KODE routine library](/products/fdd/routines). Enable the groups that match equipment and points at the site. Confirm thresholds before you rely on findings. | Rule group | Typical equipment | What it helps identify | | - | - | - | | Outdoor sensor validation | AHU, chilled water, condenser water, hot water, cooling tower | Local outdoor temperature or humidity readings that diverge from the weather reference | | Economizer monitoring | AHU | Missed free cooling or excess outside air for the conditions | | Excess conditioning | AHU, boiler, chiller | Heating or cooling that looks excessive for outdoor conditions | | Temperature reset monitoring | AHU, boiler, chiller, water systems, cooling tower | Setpoints that do not reset as expected when outdoor conditions change | | Cooling tower performance | Cooling tower | High approach temperature at maximum fan capacity when wet-bulb input is valid | Local outdoor sensors remain the preferred input for equipment monitoring where available. The Weather device provides a comparison and can supply weather context when a local reading is missing. Rule findings do not change equipment controls. Your KODE team can help select rules and confirm required points for each building. ## Next steps > [card] [Devices](/products/kode-os/devices/devices) > > Browse equipment and open device details for any building. > [card] [Trends](/products/kode-os/trends) > > Compare Weather points with equipment on a multi-point chart. > [card] [FDD routines](/products/fdd/routines) > > Configure diagnostic routines that use outdoor conditions. > [card] [Device referencing](/products/kode-os/devices/device-referencing) > > Link equipment to Weather for side-by-side Trends overlays. # Document management Source: https://docs.kodelabs.com/products/kode-os/documents/overview Upload, tag, search, filter, and manage documents in KODE OS at the portfolio and building level **Documents** in KODE OS centralizes files such as as-builts, shop drawings, warranties, and O\&M manuals. Tag each file with building, [CSI division](#csi-divisions), system, vendor, type, and tags so teams can search and filter without folder hierarchies. The **Documents** module appears at the [portfolio level](/products/kode-os/get-started/introduction#portfolio-level-modules) and [building level](/products/kode-os/get-started/introduction#visualization-and-documents) when Document Management is enabled for the client and for that site. Upload and metadata changes are desktop-only. > [!NOTE] > > The **Vendor** field and **By vendor** grouped view use the [Vendors](/products/assetops/resources/vendors) list from AssetOps. KODE OS does not maintain a separate vendor list for documents. If AssetOps is not enabled for a building, vendor options do not appear in upload, filters, or grouped view. ### Document table columns The **All documents** table can show these columns. Use the column control at the right edge of the header row to show or hide fields. Scroll horizontally when many columns are visible. | Column | Portfolio | Building | Description | | - | :-: | :-: | - | | **Name** | Yes | Yes | File name as a link. Select the name or external-link icon to open the [document detail page](#document-detail-page). | | **Building** | Yes | No | Building the document applies to. Omitted at the building level because the list is scoped to the open site. | | **Division** | Yes | Yes | Two-digit CSI division (for example, `23` for HVAC). Sortable; show or hide in the column control. | | **Section** | Yes | Yes | Six-digit CSI specification section when assigned (for example, `23 05 93`). Displayed with spacing. | | **System** | Yes | Yes | System from the platform ontology (for example, Access Control, Audio Visual) | | **Type** | Yes | Yes | [Document type](#document-types) (for example, As-Builts, Budget, Shop Drawings) | | **Tags** | Yes | Yes | Metadata tags assigned on upload | | **Vendor** | Yes | Yes | Vendor from the AssetOps [Vendors](/products/assetops/resources/vendors) list | | **Document class** | Yes | Yes | Whether the file is development, pre-occupancy, or O\&M | | **Uploaded by** | Yes | Yes | User who uploaded the file | | **Uploaded at** | Yes | Yes | Date and time the file was first uploaded | | **Last updated at** | Yes | Yes | Date and time of the most recent file or metadata change | | **O\&M document** | Yes | Yes | Legacy O\&M flag. Use **Document class** to distinguish development records from operations documents. | **Grouped view** at the building level shows **Name**, **System**, **Type**, and **Tags** by default in the group panel. The **Division** tab appears first when CSI divisions are enabled. *** ## Portfolio view Open **Documents** from the portfolio sidebar to work across all buildings where Document Management is enabled. ### All documents list The portfolio **All documents** view shows every file in scope in one table. Use **Search by name** and the filter row to narrow results. ![Portfolio Documents All Documents view with Building System Type Tag and Vendor filters and table columns including Building](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-list.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=fb99dfa97e461fd07eb8ac56715be9d5) Portfolio All documents list with Building filter and cross-site columns #### Portfolio filters * **Search by name** — Find documents by file name * **Building** — Limit results to one or more buildings * **Division** — Filter by CSI division. Results include that division and any section beneath it. For example, Division `23` also returns `23 05 93`. * **Section** — Filter by a six-digit CSI specification section. Matches include any section beneath the level you select. * **System** — Filter by system from the platform ontology. You cannot add systems manually in this module. * **Type** — Filter by [document type](#document-types) * **Tag** — Filter by one or more tags * **Vendor** — Filter by a vendor from the AssetOps [Vendors](/products/assetops/resources/vendors) list * **Document class** — Filter by development, pre-occupancy, or O\&M * **O\&M document** — Quick filter for operations and maintenance manuals Use the clear-filters control at the end of the filter row to reset dropdowns. The portfolio table supports all [document table columns](#document-table-columns), including **Building**. #### Portfolio list actions * **Upload** — Add new documents. Select a **Building** on upload. See [Upload documents](#upload-documents). * **Download** — Download a single file from the row action * **Row menu** — **Edit**, **Replace**, or **Delete**. See [Row actions](#row-actions). * **Bulk actions** — Select rows to use **Cancel**, **Download**, **Edit**, or **Delete** in the footer bar > [!WARNING] > > **Delete** removes the document. Use **Replace** on a single document when you need to keep prior versions. See [Replace and version history](#replace-and-version-history). *** ## Building view Open **Documents** from the building sidebar under **Visualization and documents** after you select a site. The list and filters apply to that building only. Use the header toggle to switch views: | View | Purpose | | - | - | | **All documents** | Single table of all documents for the open site | | **Grouped view** | Browse documents by division, system, tag, vendor, or type | ### All documents list **All documents** is the default table at the building level. ![Building Documents All Documents view with System Type Tag Vendor and O\&M Document filters and columns Name System Type Tags Vendor Uploaded At Last Updated](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-all-building.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=b15b011152b32058c8cdefdcfc7d3f7b) Building All documents list scoped to the open site #### Building filters * **Search by name** — Find documents by file name * **Division**, **Section**, **System**, **Type**, **Tag**, **Vendor**, **Document class**, **O\&M document** — Same meanings as the [portfolio filters](#portfolio-filters). The **Building** filter is not shown because the view is already scoped to the open site. The building table supports the [document table columns](#document-table-columns) except **Building**. #### Building list actions * **Upload**, **Download**, row menu (**Edit**, **Replace**, **Delete**), and bulk actions work the same as at the portfolio level. You do not select **Building** on upload because the site is already set. ### Grouped view Select **Grouped view** in the header to organize documents by category. The left panel lists groups; the right panel shows documents for the selected group. Select a grouping tab, then select a group name to load its document list. Each group shows a document count. **Grouped view** supports a split layout: groups on the left and files on the right. Collapse or resize the left pane as needed. ![Building Documents Grouped view with System Tag Vendor and Type tabs, Converged Building Network selected, and document table with Name System Type and Tags columns](https://mintcdn.com/kodelabs/3Gfg1jsPyLTzjnGt/images/kode-os/kode-os-documents-grouped-by-system.png?fit=max\&auto=format\&n=3Gfg1jsPyLTzjnGt\&q=85\&s=52aeea8b8834cdac375b3703c7cc5451) Building-level Grouped view with System selected For CSI MasterFormat grouping, use the [Division](#csi-divisions) tab. > [tab] Division > > ![Documents Grouped view Division tab listing CSI divisions with counts, Division 01 General Requirements selected, and table columns Name Section System Vendor Doc Type and Tag](https://mintcdn.com/kodelabs/3Gfg1jsPyLTzjnGt/images/kode-os/kode-os-documents-grouped-by-division.png?fit=max\&auto=format\&n=3Gfg1jsPyLTzjnGt\&q=85\&s=c56dd0cb67debae45f15aa5080534818) > > Grouped view Division tab with CSI MasterFormat list and document table > > Lists top-level [CSI divisions](#csi-divisions) with a live document count. Counts match the table results for that division, including documents tagged to specific sections beneath it. Divisions with no documents appear in a collapsible group at the bottom of the list so the full MasterFormat catalog stays one click away without crowding active divisions. > [tab] System > > ![Documents Grouped view System tab with a system selected showing document table with Name System Type and Tags columns](https://mintcdn.com/kodelabs/3Gfg1jsPyLTzjnGt/images/kode-os/kode-os-documents-grouped-by-system.png?fit=max\&auto=format\&n=3Gfg1jsPyLTzjnGt\&q=85\&s=52aeea8b8834cdac375b3703c7cc5451) > > Grouped view by system with a system group selected and document table > > Lists systems from the ontology (for example, Audio Visual, Access Control). The main panel title shows the system name followed by **Documents**. > [tab] Tag > > ![Documents Grouped View By Tag tab with Financial selected showing two documents with System and Type columns](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-grouped-by-tag.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=b31255e1f24e3b6aa6afed91bbda6dc2) > > Grouped view by tag with Financial tag selected > > Lists tags assigned to documents (for example, Financial). Use this view to find files tagged for a topic across systems and types. > [tab] Vendor > > ![Documents Grouped View By Vendor tab with ALI BABA TEST selected showing vendor documents table](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-grouped-by-vendor.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=f5a0e6b9c8a807227be25ee400696246) > > Grouped view by vendor with vendor group selected > > Lists each vendor from the AssetOps **Vendors** list with a document count. Select a vendor to see only documents linked to that provider. > [tab] Type > > ![Documents Grouped View By Type tab with Shop Drawings selected showing one document in the table](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-grouped-by-type.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=45c1fd05ef3ed7e77282888b417a0c0c) > > Grouped view by document type with Shop Drawings selected > > Lists [document types](#document-types) (for example, Shop Drawings, As-Builts, Budget). The main panel title shows the type name followed by **Documents**. Within a group, use **Search by name**, dropdown filters, **Upload**, download, row actions, and bulk actions. The grouped table shows **Name**, **System**, **Type**, and **Tags**. Switch back to **All documents** to see every file for the building in one table. *** ## CSI divisions **Division** and **Section** are metadata fields seeded from the [CSI MasterFormat®](https://www.csiresources.org/standards/masterformat2026) list at the portfolio level. They are not free text, tags, or system values. The seeded list follows the current MasterFormat standard published by the Construction Specifications Institute (CSI). | Level | Format | Required | Description | | - | - | :-: | - | | **Division** | Two digits (for example, `23`) | Yes for new uploads | Top-level CSI division. Existing documents may remain unassigned until reclassified. | | **Section** | Six digits (for example, `23 05 93`) | No | CSI specification section beneath the division | A document stores only the deepest level you assign. When you pick a section, the division fills in automatically. Sections are stored without spaces and shown with spacing, so `230593` and `23 05 93` match. ### Filter and browse by division * Filtering on **Division** `26` returns that division and sections such as `26 05 33` or `26 51 00`. * **Division** and **Section** filters combine with **System**, **Type**, **Tag**, **Vendor**, **Document class**, and **Building** (portfolio only). ### Type a section to select it In upload, bulk edit, or division selectors, type a section number or name. Spacing and punctuation are ignored, so `230593`, `23 05 93`, and `23-05-93` all match. Typing `firestop` finds `07 84 00 Firestopping` and sets Division `07`. Results outside the current selection appear under a separate heading rather than returning no matches. For example, typing `lighting` while Division `23` is selected shows that the match lives in Division `26`. ### Reclassify documents without a division Filter to documents with no **Division** to open a finite backlog list. Select rows and assign a division in [bulk edit](#bulk-edit-documents). *** ## Upload documents Select **Upload** from the portfolio or building **Documents** page to open the **Upload Document(s)** dialog. Drag files into the upload area or select files to browse. > [!NOTE] > > **File size and formats** > > * **Maximum file size:** 500 MB per file > * **Supported extensions** include Microsoft Office (`.docx`, `.xls`, `.xlsx`, `.ppt`, `.pptx`) and CAD or 3D formats (`.dwg`, `.rvt`, `.fbx`, `.3ds`, `.max`) > * **Supported MIME types** include `application/pdf`; image types such as `image/png`, `image/jpeg`, `image/gif`, `image/bmp`, `image/tiff`, and `image/webp`; and broader categories such as `application/`, `audio/`, `font/`, `example/`, `message/`, `model/`, `multipart/`, `text/`, and `video/*` > > Files outside these limits or types may fail to upload. ![Upload Documents modal with drag and drop area and Vendor Building Tags and System dropdown fields](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/kode-os-documents-upload-metadata.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=e8ae22a7d2f814096a4c531370a90dbc) Upload dialog with vendor, building, tags, and system metadata ![Upload Documents modal with Type dropdown O\&M Document checkbox and Name field for the selected file](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/kode-os-documents-upload-details.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=ca9dddf78d42c4b3cf5273ac4afb1107) Upload dialog with document type, O\&M flag, and file name **1. Add files** Drag files into **Upload documents** or select files to browse. Each selected file appears in a row with its name and size. Remove a file with the **X** on that row if needed. **2. Set context metadata** Assign metadata that drives search and filters. **Vendor** `Dropdown` Vendor from the AssetOps [Vendors](/products/assetops/resources/vendors) list. Options match vendors you create at the portfolio level in AssetOps. **Building** `Dropdown` Building the document applies to. Required when you upload from the portfolio view. At the building view, the open site is applied automatically. **Tags** `Dropdown` Select one or more existing tags from the dropdown. Use **Search** to find tags in the list. Each tag appears as a checkbox. You can assign multiple tags per document. ![Upload Documents modal Tags dropdown with Search field, checkbox list of tags such as Railings and Roofing, and Add Tag button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/kode-os-documents-upload-tags.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=0f2cdd4aa698c13007ce30d536fbeb20) Tags multi-select with search, existing tags, and Add Tag option To create a tag during upload, select **+ Add tag**, type the tag name, then press Enter to add it. The new tag is selected for the document. ![Upload Documents Tags field with Shop Drawings typed and tooltip Press enter to add the new tag](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/kode-os-documents-upload-add-tag.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=437415f6f7c6575a101c17851c8f769c) Press Enter to add a new tag while uploading **Division** `Dropdown` *required* Two-digit CSI division from the seeded MasterFormat list. When you select a **Section** first, **Division** fills in automatically. **Section** `Dropdown` Six-digit CSI specification section. Optional. Type a section number or name to jump to a match. **System** `Dropdown` System from the platform ontology. **3. Set type and name** Complete required document fields. **Type** `Dropdown` *required* Document type (for example, As-Builts). Types come from [Document types in Settings](#configure-document-types-in-settings). **Document class** `Dropdown` Whether the file is **Development**, **Pre-occupancy**, or **O\&M**. Use this field to keep liability and development records separate from operations documents. **O\&M document** `Toggle` When enabled, marks the file as an operations and maintenance document. Prefer **Document class** for new uploads. **Name** `Field` *required* Display name for the uploaded file. **4. Upload** Select **Upload** to save the document, or **Cancel** to close without saving. *** ## Row actions Open the vertical ellipsis menu on a document row in the portfolio or building list. ![Documents table row menu open showing Edit Replace and Delete options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/kode-os-documents-row-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b9da444802319d81602c280603ab7f36) Per-document menu with Edit, Replace, and Delete | Action | Description | | - | - | | **Edit** | Update metadata without changing the file | | **Replace** | Upload a new file version while keeping the document record and history | | **Delete** | Permanently remove the document | *** ## Bulk edit documents Select multiple rows in the portfolio or building list, then select **Edit** in the footer bar to update metadata for every selected document at once. Bulk edit supports **Division**, **Section**, **Tags**, **System**, **Type**, **Vendor**, **Document class**, and other shared fields. Assign **Division** in batches of 50 or more documents to reclassify backlogs efficiently. The tag picker in bulk edit supports unlimited tags with a searchable list. Tag options sort alphabetically. *** ## Document detail page Select a document **Name** link from the portfolio or building list to open its detail page. ![Document detail page showing Name Vendor Building Tags System Type Uploaded At fields and Replacement History section](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-detail.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=35e42cc468c9db08ab96ca2f54a75f67) Document detail page with metadata and replacement history The header includes **Download** and a vertical ellipsis menu for additional actions. ### Metadata | Field | Description | | - | - | | **Name** | File name as a link to open or preview the file | | **Vendor** | Vendor from the AssetOps **Vendors** list | | **Building** | Building context | | **Division** | CSI division when assigned | | **Section** | Six-digit CSI specification section when assigned | | **Tags** | Assigned tags | | **System** | System from the ontology | | **Type** | Document type | | **Document class** | Development, pre-occupancy, or O\&M document class | | **Uploaded by** | User who uploaded the file | | **Uploaded at** | Date and time the file was first uploaded | | **Last updated at** | Date and time of the most recent file or metadata change | | **O\&M document** | Whether the file is marked as an operations and maintenance document | ### Replace and version history **Replace** archives the current file as a prior version and attaches a new file to the same document record. Metadata stays with the document entity. The **Replacement history** section lists prior file versions when replacements exist. Each entry shows the file name, **Replaced at** date and time, and the user who replaced the file. When no replacements have been made, the section shows that no history is available. ![Document detail page Replacement History showing prior kode-logo.png version with row menu for Download and Restore](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-detail-replacement-history.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=8a3912e63dde3e2186ec2e3a0bb865dc) Replacement history with Download and Restore actions for a prior version Open the vertical ellipsis menu on a history row to: | Action | Description | | - | - | | **Download** | Download that prior file version | | **Restore** | Set the document back to that version. The current file moves into replacement history. | *** ## Document types Document types are categories you assign on upload and in filters (for example, As-Builts, Budget, or Shop Drawings). Configure types in portfolio **Settings** only. They apply in both portfolio and building views. ### Configure document types in Settings 1. Open **Settings** from the portfolio sidebar. 2. Select **Document types** in the Settings sub-navigation. 3. Use **Search document types** to find an existing type, or select **+ Add document type** to create one. ![Settings Document Types page with table columns Document Type and Created At, search field, and Add Document Type button](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/kode-os-documents-document-types-settings.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=257222bcd59741b5839d4f235f9751b0) Document Types in portfolio Settings with search and add actions | Column | Description | | - | - | | **Document type** | Type name used in upload and filter dropdowns | | **Created at** | Date the type was added | The table lists types such as Agreement/Contract, As-Builts, Budget, Catalogue, Change Order, Change Request, Comment Log, Cut Sheet, Design, Drawings, Evaluation, Invoice, Memo, and Network Diagram. Your organization may define additional types. After you add a type in **Settings**, it appears in the **Type** field when you [upload documents](#upload-documents) or filter a document list. See [Settings](/products/kode-os/settings#document-types) for other portfolio configuration tasks. *** ## Product enablement Document Management must be enabled per client and building in [Launchpad](/products/launchpad/channel-partners/product-enablement). Users do not see **Documents** in KODE OS when the product is disabled for that scope. *** ## Related modules > [card] [Settings](/products/kode-os/settings#document-types) > > Configure document types and other portfolio settings. > [card] [KODE OS introduction](/products/kode-os/get-started/introduction) > > See where Documents appears in portfolio and building navigation. > [card] [Vendors](/products/assetops/resources/vendors) > > Add and manage vendors in AssetOps. The Documents module uses this list for upload, filters, and grouped view. > [card] [Systems](/products/kode-os/systems) > > Review system groupings that align with document system metadata. # What is Cloud BMS? Source: https://docs.kodelabs.com/products/kode-os/get-started/introduction Cloud BMS is the cloud building management product in KODE OS. Connect systems, normalize data, and command equipment across your portfolio. [What is a building operating system](https://www.youtube.com/embed/hY9oEEXylYg?si=0uJ11kQTFmxBO7Vb) Cloud BMS is the cloud building management product in KODE OS. It connects building management systems, IoT devices, and operational tools into one layer. You monitor, analyze, and command equipment across your portfolio regardless of manufacturer. Cloud BMS includes core operations tools plus analytics modules. Those modules include [Building BI](/products/building-bi/overview), [Fault Detection and Diagnostics (FDD)](/products/fdd/overview), and the [Functional Testing Tool (FTT)](/products/ftt/overview). Related KODE OS apps such as [AssetOps](/products/assetops/quickstart/overview), [EnerG](/products/energ/get-started/introduction), and the [mobile app](/products/mobile-app/get-started/sign-in-and-workspace) extend the same data foundation. ![Cloud BMS Sites view with building list on the left and portfolio map on the right](https://mintcdn.com/kodelabs/z8J-7fbiFXxxCTJ3/images/kode-os/sites-and-map/sites-list-sort-map.png?fit=max\&auto=format\&n=z8J-7fbiFXxxCTJ3\&q=85\&s=080b762bb87b9e7b64acb429c21b8c03) Start at the portfolio Sites view, then open a building to reach site-level tools ## How Cloud BMS fits together Cloud BMS sits above your existing building systems. Connectors bring data in. Discovery finds equipment. Ontology and device templates make every site look the same. Graphics, schedules, FDD, Building BI, and other modules then work from that shared model. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph ingest["Connect"] DS["Data Sources"] end subgraph model["Standardize"] DIS["Discovery"] ONT["Ontology and templates"] end subgraph act["Operate and analyze"] OPS["Graphics, points, schedules"] MOD["Building BI, FDD, FTT"] end DS --> DIS DIS --> ONT ONT --> OPS ONT --> MOD classDef Sky stroke-width:1px,stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef Green fill:#B0E4CC,color:#285A48,stroke:#285A48 classDef Peach stroke-width:1px,stroke:#FBB35A,fill:#FFEFDB,color:#8F632D class DS Sky class DIS,ONT Peach class OPS,MOD Green linkStyle 0,1,2,3 stroke:#00C853,fill:none ``` Unlike read-only analytics platforms, Cloud BMS supports **write-back command and control**. You can change setpoints, override schedules, and command equipment from one interface. Sites can run different BMS vendors. See [Command and control points](/products/kode-os/points/commanding-points). ## What you can do Many tools in Cloud BMS are open-ended. After equipment is modeled, you can build the graphics, trends, dashboards, routines, and metrics your portfolio needs. You are not limited to the defaults shipped with each module. Common use cases include: * **Monitor and control** HVAC, lighting, fire, electrical, and other systems from [devices](/products/kode-os/devices/devices), [points](/products/kode-os/points/points), and [graphics](/products/kode-os/graphics/graphic-tool) * **Visualize** live and historical data with floor plans, system graphics, and [trends](/products/kode-os/trends) * **Automate** equipment schedules and [Optimized Start/Stop (OSS)](/products/kode-os/schedules) * **Detect faults and commission** equipment with [FDD](/products/fdd/overview) and [FTT](/products/ftt/overview) * **Build dashboards and metrics** with [Building BI](/products/building-bi/overview) * **Scale across vendors** with [device templates](/products/kode-os/devices/device-templates) so VAVs, AHUs, and meters behave the same in every building Cloud BMS connects to 200+ building systems. Supported protocols include BACnet, Modbus, DALI, MQTT, OPC, and RESTful APIs. Browse the [integrations catalog](/products/integrations/get-started/introduction) for connector details. > [!NOTE] > > Cloud BMS does not communicate with BACnet or Modbus devices directly. An on-site gateway or other middleware reads those devices and presents them to Cloud BMS. Niagara is a common gateway. MQTT connects through a broker instead. ## Who uses Cloud BMS **Building operators** monitor equipment, respond to alarms, and command points from the web app or [mobile app](/products/mobile-app/get-started/sign-in-and-workspace). **Controls and commissioning teams** connect data sources, run discovery, apply templates, and validate equipment with FTT. **Portfolio and analytics teams** compare sites, build Building BI dashboards, and track faults across the estate. **Energy and sustainability teams** use the same normalized data in [EnerG](/products/energ/get-started/introduction) for usage, emissions, and capital planning. **Administrators** provision products, users, and buildings in [Launchpad](/products/launchpad/get-started/introduction), then work in Cloud BMS day to day. ## Portfolio and building Cloud BMS organizes operations and analysis at two scopes: **portfolio** and **building**. * **Portfolio** — Cross-building view of your estate. Open analytics, mass operations, and settings before you select a site. * **Building** — Site-level operations after you select a building from `Sites`. Many modules work at both scopes. Building BI, FDD, and FTT use the same features at each level. The difference is data scope: portfolio spans sites; building focuses on one site. **Portfolio-only tools** include `Sites`, `Mass Write`, and portfolio `Settings`. **Building-only tools** include Systems, Areas, Devices, Points, Data Sources, Graphics, Trends, Schedules, and OSS. When you open Cloud BMS, you start at the portfolio level. Select a building from `Sites` to enter the building level. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR PORT["Portfolio"] -- "select building in Sites" --> BLD["Building"] PORT -- "portfolio tools" --> P1["Mass Write, Settings, portfolio analytics"] BLD -- "building tools" --> B1["Devices, Points, Graphics, Schedules"] classDef Sky stroke-width:1px,stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef Green fill:#B0E4CC,color:#285A48,stroke:#285A48 classDef Ash stroke-width:1px,stroke:#999999,fill:#EEEEEE,color:#000000 class PORT,BLD Sky class P1 Ash class B1 Green linkStyle 0 stroke:#00C853,fill:none linkStyle 1,2 stroke:#FF6D00,fill:none ``` ## Building structure Inside a building, Cloud BMS organizes the site as a hierarchy: 1. **[Areas](/products/kode-os/areas)** — Floors, rooms, and other locations 2. **[Systems](/products/kode-os/systems)** — Logical groups such as HVAC or lighting 3. **[Devices](/products/kode-os/devices/devices)** — Equipment and controllers 4. **[Points](/products/kode-os/points/points)** — Sensor values, setpoints, and commands That hierarchy is how you navigate the sidebar and how analytics attach to real equipment. ## Key concepts These ideas show up across Cloud BMS. They follow the order you typically encounter them when a building comes online. For full definitions, see the [glossary](/products/kode-os/glossary). ### Data sources and discovery A `Data Source` is a connector to an external system. [Device discovery](/products/kode-os/device-discovery) finds devices, points, and schedules from that connection so you do not configure every entity by hand. The communication score (A metric indicating the health and uptime of data source connectivity) shows how reliably a data source stays connected and delivers data. ### Ontology and device templates Ontology (The shared vocabulary for devices and points in Cloud BMS. It follows the Google Digital Buildings ontology (Google DBO).) maps manufacturer-specific labels to a shared vocabulary. Normalization (The process of standardizing point names and units across different manufacturers' systems) applies those standards. Analytics and control then work across buildings and brands. [Device templates](/products/kode-os/devices/device-templates) capture those mappings once. Apply a template to similar equipment across the portfolio. A VAV from one vendor and a VAV from another then look and behave the same in graphics, FDD, FTT, and Building BI. ### Command and control Writable points accept commands from Cloud BMS. You adjust setpoints and overrides from device details, floor plans, or Building BI tables without switching to the underlying BMS. See [Command and control points](/products/kode-os/points/commanding-points). ### Open analytics and operations modules With modeled data in place, modules share the same foundation. Build custom Building BI dashboards, FDD routines, and FTT workflows without re-integrating each site. ## Explore the platform Use these links when you know which area you need. Prefer [Next steps](#next-steps) if you are choosing a starting path. ### Core platform | Area | What it covers | | - | - | | [Sites and map](/products/kode-os/sites-and-map) | Browse the portfolio and open buildings | | [Data sources](/products/kode-os/data-sources) | Connect systems and monitor connection health | | [Device discovery](/products/kode-os/device-discovery) | Find devices, points, and schedules from a connector | | [Devices](/products/kode-os/devices/devices) and [device templates](/products/kode-os/devices/device-templates) | Configure equipment and standardize point models | | [Points](/products/kode-os/points/points) | Work with values, setpoints, and commands | | [Graphics](/products/kode-os/graphics/graphic-tool) | Build floor plans, system graphics, and device graphics | | [Schedules and OSS](/products/kode-os/schedules) | Automate equipment operation and optimize HVAC start times | | [Systems](/products/kode-os/systems) and [Areas](/products/kode-os/areas) | Organize equipment and locations in the building | ### Analytics and operations modules These modules live in Cloud BMS and have their own documentation sets. | Module | What it covers | | - | - | | [Building BI](/products/building-bi/overview) | Dashboards and visualizations across buildings and sites | | [FDD](/products/fdd/overview) | Equipment faults, events, and escalations in real time | | [FTT](/products/ftt/overview) | Automated commissioning tests and pass or fail results | ### Related apps | App | What it covers | | - | - | | [AssetOps](/products/assetops/quickstart/overview) | Work orders and asset workflows connected to Cloud BMS | | [EnerG](/products/energ/get-started/introduction) | Energy, sustainability, and finance across your portfolio | | [Launchpad](/products/launchpad/get-started/introduction) | Provision apps, users, roles, and buildings | | [Integrations](/products/integrations/get-started/introduction) | Connectors and capabilities for 200+ building systems | | [Mobile app](/products/mobile-app/get-started/sign-in-and-workspace) | On-the-go monitoring, bookmarks, and building operations | ## Next steps Pick the path that matches what you need to do first. > [card] [Operate a live building](/products/kode-os/sites-and-map) > > Open Sites, enter a building, and move into graphics, points, and schedules. > [card] [Connect and model equipment](/products/kode-os/data-sources) > > Add a data source, run discovery, then standardize devices with templates. > [card] [Build analytics or monitor faults](/products/building-bi/tutorials/build-your-first-dashboard) > > Create a Building BI dashboard, or jump to FDD when you are ready to monitor faults. > [card] [Look up a term](/products/kode-os/glossary) > > Find definitions for Cloud BMS, ontology, discovery, and related product terms. # KODE glossary Source: https://docs.kodelabs.com/products/kode-os/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Device graphics Source: https://docs.kodelabs.com/products/kode-os/graphics/device-graphics Create and interact with equipment-level visual representations showing live point data, status indicators, and control options. > [!NOTE] > > Device graphics are a building-level feature. Select a building from the [sites list](/products/kode-os/sites-and-map) to access device graphics through the Devices module or Graphic Tool. Device graphics are equipment-level visual representations that display live point data, status indicators, and interactive controls for a single device. They provide a focused view of how an individual piece of equipment is operating, making them valuable for troubleshooting, commissioning, and day-to-day monitoring. ## Access a device graphic You can reach a device graphic from two locations: * **Device details page** -- select a device from the [devices list](/products/kode-os/devices/devices), open its details, and click the `Graphic` tab * **Graphics module** -- click `Graphics` in the left sidebar, select the `Devices` tab, and open an existing device graphic ![Graphics module showing the Devices tab with device graphic cards, and a three-dot menu expanded on VAV\_310 showing Edit, Save as template, and Delete options](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-list-menu.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=95b54e8ec61094932386f805c40cffd9) The Graphics module Devices tab lists device graphics with options to edit, save as template, or delete From the Devices tab in the Graphics module, click the three-dot menu on a graphic card to access `Edit`, `Save as template`, or `Delete` options. ## Create a device graphic You can create a device graphic from two entry points: * **Device details page** -- navigate to a device, click the `Graphic` tab, and click `+ Create New` * **Graphics module** -- click `Graphics` in the left sidebar, select the `Devices` tab, and click `New Graphic` ![VAV\_304 device details page showing the Graphic tab with Apply Template and Create New buttons on an empty canvas](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-empty-state.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=908a31bed65101a49d9d06ce3f84fb4a) The Graphic tab on a device shows options to apply a template or create a new graphic Click `+ Create New` to open the New Device Graphic dialog. ![New Device Graphic dialog with fields for Graphic Name, Device dropdown showing VAV\_304, Description, and a Device File drag-and-drop upload area](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-new-device-graphic.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=fa8ebac261a3372c2f37556708b97832) The New Device Graphic dialog collects the graphic name, device assignment, description, and an optional device file upload **Graphic Name** `Field` Enter a descriptive name for the device graphic. **Device** `Field` The device this graphic belongs to. When creating from the device details page, this is pre-filled. When creating from the Graphics module, select the device from the dropdown. **Description** `Field` Add an optional description of the graphic's purpose. **Device File** `Field` Upload a background image, equipment diagram, or schematic. Drag and drop a file, click `Browse files` to upload from your computer, or click `Browse from files` to select from previously uploaded files. Click `Done` to create the graphic and open it in the [Graphic Tool](/products/kode-os/graphics/graphic-tool) editor. ## Build the device graphic The Graphic Tool editor provides three tabs for building device graphics: Devices, Elements, and Basics. ### Devices tab The `Devices` tab lists all devices and their points. The main device assigned to this graphic appears at the top of the list with a red flag icon. A green checkmark with a number indicates how many points from that device are already placed on the graphic. ![Graphic Tool editor showing the Devices tab with VAV\_407 flagged as the main device, a 3D AHU model on the canvas with point markers showing Discharge Air Temp and other readings](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-devices-tab.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=98ab83324140d7261efaf574158eeaf6) The Devices tab shows the main device with a red flag and all available devices with their points Expand a device to see its points with current values. Drag a point onto the canvas to place a marker at the corresponding location on the diagram. You can add points from any device, not only the main device assigned to the graphic. ### Elements tab The `Elements` tab lists all elements placed on the graphic canvas, including device markers and text labels. Select an element from the list to highlight it on the canvas and access its style options. ![Graphic Tool showing the Elements tab with VAV\_409, VAV\_407, and Text entries listed, and the device graphic on the canvas](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-elements-tab.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=fa6d17806d21e69ccd2dd13ac3ae1f63) The Elements tab lists placed elements such as device markers and text labels ### Basics tab The `Basics` tab contains shapes, device widgets, uploads, and built-in drawings for constructing device graphics. ![Graphic Tool showing the Basics tab with Shapes, Device Widgets, Uploads, and Drawings sections including AHU Elements with Sensor and Fan categories](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-basics-tab.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=5113a78a0f66c3f3bad115685e953466) The Basics tab provides shapes, device widgets, uploads, and built-in drawing components * **Shapes** -- add rectangles, circles, triangles, arrows, polygons, lines, and text labels * **Device Widgets** -- add device tables, zone tools, and pivot tables * **Uploads** -- upload custom images from your computer * **Drawings** -- use pre-built equipment components (AHU elements, sensors, fans, coils) from the built-in library For details on each section, see the [Graphic Tool Basics tab](/products/kode-os/graphics/graphic-tool#basics-tab) documentation. ## Save as template Device graphics can be saved as templates and applied to other devices of the same type. Click `Save as template` in the upper right corner of the editor. ![Save as template dialog with Template Name field showing VAV Template, a Description field, and Cancel, Save and Apply, and Save buttons](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-save-template.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=6ebb88f80da7b770aec5309e6f28acd7) The Save as template dialog lets you name and describe the template **Template Name** `Field` Enter a name for the template (for example, `VAV Template`). **Description** `Field` Add an optional description for the template. * **Save** -- saves the template for future use * **Save and Apply** -- saves the template and opens the Apply Template dialog, where you can select other devices to apply the template to ![Apply Template dialog showing a search field with vav\_310 entered, a device list with VAV\_310 on Floor 3, and Close and Next buttons](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-apply-template.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=686d26e5baf4a4d1ad4aa541cff7569c) The Apply Template dialog lets you search and select devices to apply the template to Search for devices by name, filter by type or area, and select the devices you want to apply the template to. Click `Next` to proceed. On the next step, choose how the template maps points to the target devices: * **Ontology field** -- matches points based on their ontology classification * **Point name** -- matches points based on their exact point names The `Compatibility` column shows how many points from the template match the target device (for example, `6/6` means all six points matched). ![Apply Template dialog with Ontology field selected, showing VAV\_310 with 6 out of 6 compatibility](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-template-ontology.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=329d14f0156e67730745f7e31fd5a5db) Apply template based on Ontology field matching, showing compatibility score per device ![Apply Template dialog with Point name selected, showing VAV\_310 with 6 out of 6 compatibility](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-template-pointname.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=69b97373d1e8e29903193cae5ff32902) Apply template based on Point name matching Select the target devices and click `Apply`. The Activity Log tracks the template application status. ![Activity Log showing Graphic Template VAV\_310 with Completed status](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-template-activity.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=b91923b9991b4a506c8bbfb50dc4fab0) The Activity Log confirms the template was applied successfully Once applied, the target device's Graphic tab displays the same layout and markers as the original template. ![VAV\_310 device Graphic tab showing the applied template with a 3D AHU model, point markers, and live data values](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-template-result.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=4873a9ac89c65b13e80da35b01dba5af) The device graphic on VAV\_310 after applying the VAV Template You can also apply a saved template from a device's `Graphic` tab by clicking `Apply Template`. ## Manage device templates Click `Templates` at the bottom of the Graphics module sidebar to view all saved device templates. ![Graphics module showing the Templates link in the sidebar and the Device Templates page with a VAV Template card, search bar, and Import Template button](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-nav.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=c417b65c3739d2417670207791aac7fc) The Templates page in the Graphics module shows saved device templates with search and import options Click the three-dot menu on a template card to access management options. ![Device Templates page with three-dot menu expanded on VAV Template showing Apply template, Export template, and Delete options](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-menu.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=7cadba53c360e22e0e9d1d251086abe4) The three-dot menu on a template card provides Apply template, Export template, and Delete options ### Apply a template Select `Apply template` to open the Apply Template dialog. Search and select the devices you want to apply the template to, then click `Next`. ![Apply Template dialog showing a list of VAV devices with Device, Type, and Area columns, a search bar, and filter options](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-apply-select.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=b7d2d2ecf0b8e836cffc22375693c554) Select devices to apply the template to from the searchable device list Choose the matching method (Ontology field or Point name), review the compatibility scores, and click `Apply`. ![Apply Template confirmation showing VAV\_304 with 6 out of 0 compatibility and VAV\_101 with 6 out of 6 compatibility](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-apply-confirm.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=158843a76be9f82108598dd40039ed1c) Review compatibility scores before applying the template to selected devices ### Export and import templates Select `Export template` from the three-dot menu to generate a shareable link. The link is copied to your clipboard automatically. ![Export Link Generated notification showing the link has been copied to clipboard with instructions to use the import button](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-export.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=a21783f0363ca87f1bb0630767e5da44) A notification confirms the export link has been generated and copied to the clipboard To import a template from another building or site, click `Import Template` at the top right of the Device Templates page. Paste the exported link, enter a name and canonical type, and add an optional description. ![Import Template dialog with fields for Import URL, Name showing FCU Template, Canonical Type showing fcu, and Description](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-templates-import.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2b518e5291a19e031c1a302e3035d6d3) The Import Template dialog accepts the exported link, a template name, canonical type, and description **Import URL** `Field` Paste the template link copied from the export step. **Name** `Field` Enter a name for the imported template (for example, `FCU Template`). **Canonical Type** `Field` The device type this template applies to (for example, `fcu`). This value is carried over from the exported template and cannot be edited. **Description** `Field` Add an optional description for the template. Click `Save` to add the template to your Device Templates library. ## Interact with writable points Writable points on a device graphic display an interactive indicator. Click a writable point marker to open the command panel. The panel displays the device's variables on the left and the action form on the right. ![Command panel for VAV\_301 showing variables including Discharge Air Flow, setpoints, and cooling flow on the left, with action fields for Priority, Value, Duration, Reason, and Specific Reason on the right](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-device-command-panel.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=d0e47fb457de2d7d2c0c9dcd1eb0f15b) The command panel shows device variables and the action form for overriding a point value * **Priority** -- select the command priority level (for example, `Override`) * **Value** -- set the target value. Use `+` and `-` to adjust. * **Duration** -- specify how long the command remains active. Check `Permanent` for an indefinite override. * **Reason** -- select a predefined reason from the dropdown * **Specific Reason** -- enter a custom reason for the change The bottom of the panel displays the current priority level and value. Click `Save Changes` to send the command, or `Close` to cancel. Click `Activity Log` in the upper right corner to view the command history. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ## Tables on device graphics Add table views to a device graphic to display multiple point values in a structured format. Tables are useful when a device has many points that do not map well to specific positions on a diagram. * Select points from the device (or from related devices) * Tables support two columns: point name and current value * Customize colors, column width, and font sizes * Batch-edit table styling across the graphic ## Use device graphics for troubleshooting Device graphics support troubleshooting by providing a visual context for equipment behavior: * **Ductwork and airflow visualization** -- position supply air, return air, mixed air, and exhaust temperature readings along the airflow path to trace issues through the system * **Valve and damper positions** -- display valve and damper positions alongside their corresponding temperature or pressure readings to identify control loop problems * **Alarm and fault indicators** -- point status icons (alarm, down, fault, stale, overridden) appear next to markers, highlighting which points have active issues * **Setpoint comparison** -- use difference-from-setpoint smart markers to visually identify when a device is not achieving its target ### Common troubleshooting scenarios | Scenario | What to look for on the graphic | | - | - | | Comfort complaint in a zone | Compare zone temperature against the cooling or heating setpoint. Check if the VAV damper is fully open or the valve is at the expected position. | | AHU not maintaining supply temperature | Verify the cooling valve position and chilled water temperatures. Check the mixed air damper and outdoor air readings. | | Equipment cycling | Watch the run status and command points for rapid on/off transitions. Compare against the setpoint and deadband. | | Sensor disagreement | Overlay supply, return, and zone temperatures to identify readings that diverge from expected patterns. | ## Next steps > [card] [Graphic Tool](/products/kode-os/graphics/graphic-tool) > > Learn about smart markers, zones, layers, and settings for all graphic types. > [card] [System graphics](/products/kode-os/graphics/system-graphics) > > Create system-level schematics with live data overlays. > [card] [Floor plan graphics](/products/kode-os/graphics/floor-plans) > > View devices on spatial floor plan layouts. # Floor plan graphics Source: https://docs.kodelabs.com/products/kode-os/graphics/floor-plans Place devices on floor plans, configure smart markers, zone drawings, tables, and interactive data overlays using the Graphic Tool. > [!NOTE] > > Floor plan graphics are a building-level feature. Select a building from the [sites list](/products/kode-os/sites-and-map) to access floor plans through the Areas module. Floor plan graphics display building floor plans with device locations and live data overlays. The [Graphic Tool](/products/kode-os/graphics/graphic-tool) provides advanced features including smart markers, tables, zone drawings, hover-over interactions, and layer configurations that go beyond basic device placement. For 3D BIM models on area dashboards, see [Add a BIM model to an area](/products/kode-os/areas#add-a-bim-model-to-an-area). ## Navigate to a floor plan **1. Select your site** Click `Sites` in the left navigation bar and select the building. **2. Open areas** Click `Areas` in the left sidebar menu. Select a floor from the area list. **3. View the floor plan** The floor plan displays with device pins and live data overlays for the selected floor. ## Interact with devices on the floor plan Each device appears as a marker on the floor plan with its current value displayed. Devices are color-coded by status: * **Green** means the device is online and operating normally * **Red** means the device has an active alarm * **Grey** means the device is offline Click a **device pin** to open a quick-access panel with options to view readings, command writable points, or navigate to device details. Click a **smart marker** to open the command dialog for that device's writable points. You can also hover the marker, then click the edit icon next to a writable value. See [Command and control points](/products/kode-os/points/commanding-points). > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ## Create a floor plan graphic Before creating a floor plan graphic, make sure you have [created an area](/products/kode-os/areas#add-areas) in the Areas module. The graphic must be linked to an existing area. Navigate to `Graphics` in the left sidebar and select the `Floor Plans` tab. Click `New Graphic` and select the area to link the graphic to. You can also create a floor plan from within an area by opening the area dashboard and [adding a graphic widget](/products/kode-os/areas#add-a-graphic-widget-to-an-area). ## Place devices on floor plans **1. Enter edit mode** Navigate to the floor plan view. Click the three-dot menu and select `Edit`. **2. Select a layer** Use the layer tabs in the bottom toolbar to select the device category layer. **3. Drag devices onto the plan** From the `Devices` tab on the left panel, drag equipment onto the floor plan at their physical locations. Zoom in for precise placement. ![Graphic Tool workspace showing the Devices tab with FC\_4 devices on the left and a Floor 04 plan with color-coded temperature markers on the right](https://mintcdn.com/kodelabs/_rqeCWviVM7jraZ_/images/kode-os/graphics/kode-os-graphics-canvas-devices.png?fit=max\&auto=format\&n=_rqeCWviVM7jraZ_\&q=85\&s=ddbd62d0497fb0c8690117409f68fc36) The Devices tab lists all devices and points available for the selected area **4. Use auto-suggest** Switch to the temperature layer and click `Auto Suggest` in the upper right corner. Cloud BMS maps the temperature points to the placed devices. **5. Save the placement** Click `Save` to finalize the device placement. ## Smart markers Smart markers provide dynamic, color-coded visualizations based on live point values. Instead of showing a static icon, smart markers change their appearance as values enter different ranges. ![Floor plan smart marker for FC\_4\_5 showing Occupancy command Occupied, Discharge Fan command On, cooling and heating setpoints, and Zone Temp 24.6 degrees Celsius with an alarm](https://mintcdn.com/kodelabs/_rqeCWviVM7jraZ_/images/kode-os/graphics/kode-os-graphics-temperature-markers.png?fit=max\&auto=format\&n=_rqeCWviVM7jraZ_\&q=85\&s=86ab8cbe91ddcaf9bee2d9fc2acb2f87) Selecting a smart marker on the floor plan opens a panel with live point values, setpoints, and alarm status Each smart marker supports three display modes: * **Icon only** -- the marker displays as a colored icon reflecting the current value range * **Value only** -- the marker displays the numeric value with color coding * **Icon and value** -- the marker displays both the icon and the value The color rules and ranges are configured in the [Graphic Tool settings](/products/kode-os/graphics/graphic-tool#settings). For each marker, you select a point and a smart marker configuration. See the [Graphic Tool](/products/kode-os/graphics/graphic-tool#smart-markers) for full details on smart marker display options and marker style configuration. ### Difference from setpoint smart markers These smart markers change appearance based on how far the current value is from the device's setpoint. This is useful for quickly identifying zones that are not achieving their target temperature. ![Floor plan with difference from setpoint smart markers showing green markers within tolerance and red markers exceeding tolerance, with bell icons indicating active FDD alarms](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-setpoint-markers.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=f37b8a49f6a6db0b1567f87c642e341b) Green markers indicate values within tolerance. Red markers exceed tolerance. The bell icon signals an active FDD alarm. * **Green** markers indicate the current value is within the configured tolerance of the setpoint * **Red** markers indicate the value has drifted beyond the tolerated deviation * The **bell icon** on a marker indicates that the point has an active alarm generated by [FDD](/products/fdd/overview) * Hovering over a marker reveals the device name, current value, and effective setpoint * Supports dual setpoints for heating and cooling modes ## Tables in graphics Table views list point values from devices directly within floor plan graphics. Drag the **Device Table** widget from the `Basics` tab onto the canvas to create a table. ![Add new table dialog showing a device list with FCU208 expanded to reveal individual points with live values](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-add-table.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2267da9fdaee0583f0f28a83f942670a) Select a device and check the points you want to display in the table Expand a device to see its points with current values. Check the points you want to include, then click `Save`. The table appears as a single element on the graphic that you can move and resize. > [!TIP] > > Use the batch style editor to update the appearance of all tables in a graphic at once. See the [Graphic Tool](/products/kode-os/graphics/graphic-tool#device-table) for table style configuration details. ## Zone drawings and control Zone drawings define colored regions on a floor plan that change appearance based on live device data. Click the **Zone Tool** widget from the `Basics` tab, then click on the floor plan to draw the zone outline. Each click places a point that defines a start and end line of the zone boundary. Close the shape to complete the zone. ![Zones Configuration panel with Properties, States, Style, and Navigation sections for a selected zone on a floor plan](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-zone-config.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=95c144e979038be28b5fd496b0b89dcf) The Zones Configuration panel defines the zone's data source, states, style, and navigation behavior Select a zone to configure it. The configuration panel contains: * **Properties** -- select the data type (`Number` or `String/Boolean`), controlling devices, the common point, and the aggregation operator (`AVG`, `MIN`, `MAX`, `SUM`, `MED` for numeric points; `AND` or `OR` for boolean/enum points) * **States** -- define value ranges with corresponding colors. Select a `Smart Configuration` or create custom ranges manually. ![Zone States configuration showing five value ranges with corresponding colors ranging from blue through green to red](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-zone-states.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=b393f0114b046be7ef140b1755f1bb94) Each state maps a value range to a color. The zone changes color as the aggregated value moves between ranges. * **Style** -- set the zone name and default zone color * **Navigation** -- link the zone to a URL or a Cloud BMS device, area, or system See the [Graphic Tool](/products/kode-os/graphics/graphic-tool#zone-tool) for full zone configuration details. > [!NOTE] > > The current version supports one point reference per zone. Each zone evaluates a single point type across the devices within its borders. ## Floor plan sections Floor plan sections keep a large floor on one graphic. You draw optional nested sections (up to three levels) with the zone drawing tool. Markers, zones, and other content placed inside a section stay hidden until someone enters that section. Existing floor plans that do not use sections behave the same as before. Split floor plans are not migrated automatically. ### Enter and leave a section * Click a section, or zoom into it, to enter. The view fits to that section and shows the content inside it. * Zoom out to return to the previous view. * Content outside sections stays visible on the main floor view. ### Create sections **1. Enter edit mode** Open the floor plan and select `Edit`. **2. Draw a section** Use the zone drawing tool to outline the section on the canvas. Nest sections up to three levels when a floor needs more detail. **3. Place content inside the section** Add markers, zones, and other graphic elements inside the section boundary. That content appears only after a viewer enters the section. **4. Save** Select `Save`. Viewers enter the section by click or zoom. Canvas images support up to 3840×2160 (4K) so large floor plans stay clear when zooming. Apps that embed the graphic can control presentation. For example, a space utilization view can open on room zones and skip outer sections, or show zones without markers. Configure those presentation options in the app that hosts the graphic. ## Hover-over markers Hover-over markers allow you to reference multiple points on a single marker while showing only one value by default. The additional points appear when the user hovers over the marker. ![Hover-over marker on a floor plan showing VAV\_203 with Zone Temp Setpt and Zone Temp values expanded on hover](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-hover-marker.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=9a26c8a992a5feefcdd0f7b4b23366e9) Hovering over a smart marker reveals the device name and additional point values * Works with both smart markers and default markers * Marker headers and labels can be hidden until hover * When used with smart markers, hovering shows the device name with a link to navigate to device details ## Point statuses and states Markers on floor plans display real-time status indicators next to point values: | State | Indicator | Meaning | | - | - | - | | **Alarm** | Red icon | Active alarm condition | | **Down** | Grey icon | Device or point is not communicating | | **Fault** | Orange icon | Fault condition detected | | **Stale** | Yellow icon | Value has not updated within the expected interval | | **Overridden** | Purple icon | Point is currently overridden by a manual command | Status icons are enabled by default on smart markers. ## Layers and overlays Layers organize a floor plan graphic into multiple views. Each layer displays its own set of markers, tables, and points. Switch between layers using the tabs in the bottom toolbar. ![Floor plan with blue and purple duct overlays showing supply and return duct routing across the building](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-overlay-ducts.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=4266768ff50416834e3907e062e76747) A duct overlay rendered on top of a floor plan, showing supply and return duct paths in separate colors Overlays are visual elements (such as ductwork or piping paths) that render on top of the floor plan and can be toggled on or off independently from layers. See the [Graphic Tool](/products/kode-os/graphics/graphic-tool#layers) for details on creating layers and overlays. ## Filter the floor plan Use the system type tabs at the top of the floor plan view to filter visible devices: * **HVAC** shows temperature devices, AHUs, VAVs, and related equipment * **Lighting** shows lighting controllers and fixtures * **Fire Detection** shows smoke detectors, pull stations, and alarm panels Additional display options in the upper right corner: * **Icons** toggles between value labels and icon-based display for dense floors * **Legend** shows or hides the icon legend ## Next steps > [card] [Graphic Tool](/products/kode-os/graphics/graphic-tool) > > Configure smart markers, zones, layers, and global settings for all graphic types. > [card] [System graphics](/products/kode-os/graphics/system-graphics) > > Create schematic diagrams with live data overlays. > [card] [Areas](/products/kode-os/areas) > > Add and manage the spatial zones displayed on floor plans. # Graphic Tool Source: https://docs.kodelabs.com/products/kode-os/graphics/graphic-tool Build and customize floor plan, system, and device graphics with smart markers, zones, tables, and layers in the Cloud BMS Graphic Tool. > [!NOTE] > > The Graphic Tool is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access the Graphic Tool for that site. The Graphic Tool is the built-in visual editor in Cloud BMS used to assemble and configure interactive floor plan, system, and device graphics. It provides features for placing devices, drawing zones, configuring smart markers, building system schematics, and managing layers. ## Access the Graphic Tool Click `Graphics` in the left navigation bar to open the Graphics module. The module organizes graphics into three categories accessible from the secondary sidebar: `Floor Plans`, `Devices`, and `Systems`. ![Graphics module showing the Floor Plans tab with a list of existing floor plan graphics and a New Graphic button](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-floor-plans-list.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=59fe7f497e60437a85e025a74e1847a1) The Graphics module lists existing graphics by category with options to search and create new ones You can also enter the Graphic Tool from within any existing graphic by clicking the edit (pencil) icon. ## Create a new graphic Click `New Graphic` in the upper right corner. A dialog prompts you to configure the graphic details. ![New Area Graphic creation dialog with fields for graphic name, area, description, and floor plan file upload](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-new-area-graphic.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=dad26280a1e8bb2fd519a905d77445af) The New Area Graphic dialog collects the graphic name, area assignment, description, and floor plan file **Graphic Name** `Field` Enter a descriptive name for the graphic (for example, `Floor 03`). **Area** `Field` Select the area this graphic represents. The area determines which devices are available for placement. **Description** `Field` Add an optional description to provide context for the graphic. **Floor Plan File** `Field` Upload a floor plan image by dragging and dropping a file or clicking `Browse files`. You can also select an existing file from the file library using `Browse from files`. ## The Graphic Tool workspace The workspace consists of the canvas area on the right and a panel on the left with three tabs: `Devices`, `Elements`, and `Basics`. The bottom toolbar provides layer tabs and overlay controls. ### Top toolbar The top toolbar provides canvas-level controls for editing and navigating the graphic. ![Graphic Tool top toolbar showing selection, view, grouping, lock, visibility, undo, redo, background color, edit details, layout options, and zoom controls](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-toolbar.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=e8f307c0b8a1647c683993dc25663296) From left to right, the toolbar contains: | Icon | Action | | - | - | | **Arrow** (selection) | Enable editing mode. Select, move, and resize items on the canvas. | | **Hand** (pan) | Switch to view mode. Pan across the canvas without selecting items. | | **Single square** (group) | Group multiple selected items into a single unit. Select items first, then click to group. | | **Double square** (ungroup) | Treat selected items as separate elements for individual editing. | | **Lock** | Lock a selected item in place to prevent accidental movement. Available when an item is selected. | | **Eye** | Toggle visibility of a selected item on the graphic. Available when an item is selected. | | **Undo / Redo** | Reverse or reapply the last action. | | **Background Color** | Change the canvas background color. | | **Edit Graphic Details** | Update the graphic name, area, and description. | | **Layout Options** | Configure canvas layout and display preferences. | | **Zoom controls** | Zoom in, zoom out, fit to screen, and view the current zoom percentage. | ## Devices tab The `Devices` tab lists all devices and points available for the selected area. Expand a device to see its points, then drag and drop them onto the canvas to place markers. ![Graphic Tool workspace showing the Devices tab with FC\_4 devices on the left and a Floor 04 plan with color-coded temperature markers on the right](https://mintcdn.com/kodelabs/_rqeCWviVM7jraZ_/images/kode-os/graphics/kode-os-graphics-canvas-devices.png?fit=max\&auto=format\&n=_rqeCWviVM7jraZ_\&q=85\&s=ddbd62d0497fb0c8690117409f68fc36) The Graphic Tool workspace with the device panel on the left and the floor plan canvas on the right ### Smart markers Smart markers provide dynamic, color-coded visualizations that change appearance based on live point values. Unlike default markers that show a static icon and value, smart markers apply rules and ranges to reflect the current state of a point. ![Floor plan smart marker for FC\_4\_5 showing Occupancy command Occupied, Discharge Fan command On, cooling and heating setpoints, and Zone Temp 24.6 degrees Celsius with an alarm](https://mintcdn.com/kodelabs/_rqeCWviVM7jraZ_/images/kode-os/graphics/kode-os-graphics-temperature-markers.png?fit=max\&auto=format\&n=_rqeCWviVM7jraZ_\&q=85\&s=86ab8cbe91ddcaf9bee2d9fc2acb2f87) Selecting a smart marker on the floor plan opens a panel with live point values, setpoints, and alarm status For each marker, you select a point and a smart marker configuration. The rules that determine how the marker changes color are managed in the [Graphic Tool settings](#settings). #### Smart marker display options Enable the `Smart Marker` toggle on any marker to access smart marker configuration. The following options control how the marker renders on the canvas: **Point** `Field` Select the point that drives the marker's value and color behavior. **Configuration** `Field` Choose a smart marker configuration that defines the value ranges and color rules. Configurations are created in the [Graphic Tool settings](#smart-marker-settings). **Include value** `Toggle` Display both the icon and the numeric value on the marker. **Icon only** `Toggle` Display only a colored icon reflecting the current value range. **Value Only** `Toggle` Display only the numeric value with color coding applied. **Color will be applied to** `Field` Choose whether the smart marker color applies to `Icon/value` (the text and icon) or `Background` (the marker container). **Show Device Name** `Toggle` Display the device name alongside the marker on the canvas. **Always Display Marker as Smart** `Toggle` Force the marker to always render as a smart marker regardless of layer defaults. #### Marker style options Each marker's visual appearance is configurable through the lower section of the Markers panel: **Layout** `Field` Choose a layout preset (`Default` or other variants) and select between rounded or square corners for the marker container. **Point Value** `Field` Set the font size (in pixels), toggle bold formatting, and choose the text color for the displayed point value. **Marker Icon** `Toggle` Show or hide the marker icon. Expand this section to configure icon appearance. Click `Save Style` to apply changes or `Reset Style` to revert to the default appearance. #### Difference from setpoint markers Difference from setpoint markers compare the current value against the device's setpoint. Configure a tolerated deviation (as an absolute value or percentage), and the marker changes color when the value drifts outside the acceptable range. ![Floor plan with difference from setpoint smart markers showing green markers within tolerance and red markers exceeding tolerance, with bell icons indicating active FDD alarms](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-setpoint-markers.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=f37b8a49f6a6db0b1567f87c642e341b) Green markers indicate values within the tolerated deviation from the setpoint. Red markers indicate values that exceed the tolerance. The bell icon signals an active FDD alarm on that point. * **Green** markers indicate the current value is within the configured tolerance of the setpoint * **Red** markers indicate the value has drifted beyond the tolerated deviation * The **bell icon** on a marker indicates that the point has an active alarm generated by [FDD](/products/fdd/overview) * Hovering over a marker reveals the device name, current value, and effective setpoint These markers support dual setpoints for devices with separate heating and cooling modes, and can optionally display the delta value. ### Hover-over markers Hover-over markers allow you to reference multiple points on a single marker while showing only one value by default. Additional points appear when the user hovers over the marker. ![Hover-over marker on a floor plan showing VAV\_203 with Zone Temp Setpt and Zone Temp values expanded on hover](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-hover-marker.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=9a26c8a992a5feefcdd0f7b4b23366e9) Hovering over a smart marker reveals the device name and additional point values * Works with both smart markers and default markers * Marker headers and labels can be hidden until hover * When used with smart markers, hovering reveals the device name with a link to device details ### System markers System markers act as navigation links between graphics. Drag a system from the `Systems` panel in the left-hand elements menu onto any graphic to create a clickable marker that navigates to that system's graphic view. System markers are useful for: * Linking related system graphics (for example, AHU graphic to chiller plant graphic) * Navigating from floor plans to system schematics * Creating a connected network of visual interfaces ### Point statuses and states All markers on graphics display real-time status indicators next to point values: | State | Indicator | Meaning | | - | - | - | | **Alarm** | Red icon | Active alarm condition on this point | | **Down** | Grey icon | Device or point is not communicating | | **Fault** | Orange icon | Fault condition detected | | **Stale** | Yellow icon | Value has not updated within the expected interval | | **Overridden** | Purple icon | Point is currently overridden by a manual command | Status icons are enabled by default on smart markers. ### Batch editing and alignment Select multiple markers by dragging the mouse over them or by holding Shift and clicking individually. Perform batch updates to marker properties, move all selected markers as a group, or delete them in bulk. Align multiple selected elements using the alignment toolbar: * `Left`, `Right`, `Top`, `Bottom` alignment * `Middle vertically` and `Middle horizontally` centering ### Right-click context menu Right-click any marker or element on the canvas to access the following actions: | Action | Description | | - | - | | `Duplicate` | Create a copy of the selected element in place | | `Duplicate and Place` | Duplicate the element and assign it to a different device of the same type. A dialog lists all matching devices so you can create copies with identical style and configuration. | | `Copy to` | Copy the element to another layer in the graphic | | `Delete` | Remove the element from the canvas | | `Edit Points` | Open the point selection dialog to add or remove points on the marker | | `Bring to front` | Move the element above all other elements in the stacking order | | `Send to back` | Move the element behind all other elements in the stacking order | | `Lock/Unlock` | Lock the element in place to prevent accidental movement, or unlock a locked element | ## Elements tab The `Elements` tab lists all items placed on the current graphic, including devices, markers, zones, and other elements. Use this tab to locate, select, and manage individual items. ![Elements tab showing a list of placed devices and zones with lock and visibility icons next to each item](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-elements-tab.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=122258c079054e8b093919249bb43bab) The Elements tab lists all placed items on the graphic, with lock and visibility controls available per item Hover over an item to reveal the **lock** and **eye** icons for that element. Hold Shift and click to select multiple items, then batch-apply lock or visibility changes to the entire selection. ## Basics tab The `Basics` tab provides shapes, device widgets, uploaded files, and a library of pre-built drawing components for annotating and building graphics. ![Basics tab showing Shapes section with rectangle, circle, triangle, and other shape tools, Device Widgets, Uploads, and a Drawings library with AHU sensor components](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-basics-tab.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=f04873e52086394881e79930fa17fca8) The Basics tab contains shapes, device widgets, uploaded files, and a searchable library of drawing components organized by category ### Shapes Drag shapes onto the canvas to annotate or highlight areas. Available shapes include rectangle, circle, triangle, polygon, drop, line, arrow, and text. #### Shape style Select a shape on the canvas to open the Shape Style panel on the right. ![Shape Style panel showing Format, Fill, Stroke, and Navigation configuration sections for a selected rectangle shape on a floor plan](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-shape-style.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=d463fdba28334f8ccc208c1dbae4dd64) The Shape Style panel configures format, fill, stroke, and navigation properties for a selected shape * **Format** -- set the `Width`, `Height`, and `Corners` (border radius) in pixels. Toggle `Aspect Ratio` to maintain proportions when resizing. * **Fill** -- choose a `Fill Color` and optionally apply a `Hatching Combinations` pattern. * **Stroke** -- toggle stroke visibility, set the `Fill Color` and stroke width in pixels. * **Navigation** -- make the shape interactive by selecting `Insert URL` to link to an external page, or `Link a Device, Area or System` to navigate to a Cloud BMS resource when clicked. ### Device widgets The Device Widgets section contains three drag-and-drop tools for displaying device data on the canvas. #### Device table Table views display point values from one or more devices directly within a graphic. Drag the **Device Table** widget onto the canvas, or click it to open the creation dialog. ![Add new table dialog showing a device list with FCU208 expanded to reveal individual points with live values](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-add-table.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=2267da9fdaee0583f0f28a83f942670a) Select a device and check the points you want to display in the table Expand a device to see its points with current values. Check the points you want to include, then click `Save`. The table appears as a single element on the canvas that you can move and resize. **Table style** Select a table on the canvas to open the Table Style panel. The following sections control the table's appearance: * **Layout** -- choose a layout preset (`Default` or alignment variants) for content arrangement within the table * **Table Header** -- configure the header text, font size, bold formatting, text color, and `Header Color` background. Toggle `Wrap text` to allow long headers to wrap to multiple lines. * **Borders** -- toggle border visibility and customize border appearance * **Point Label** -- set the `Column Width` in pixels for the point name column and toggle `Wrap Text` * **Rows** -- configure the row font size, bold formatting, text color, and `Row Color` background * **Point Value** -- set the `Column Width` in pixels for the value column and toggle `Wrap Text` * **Point Configuration** -- reorder points using the draggable `Point Order` list. Click the edit icon next to a point to rename its label in the table. * **States Configuration** -- define color states for table rows based on point values, similar to zone states. Click `+ Add state` to create value-to-color mappings. **Setpoint highlighting** Highlight a specific setpoint value on a table to draw attention to the target alongside the current reading. Enable the `Highlight Setpoint` toggle in the Properties section of the style panel to configure it. ![Highlight Setpoint configuration showing States Configuration with ontology and smart configuration selections, and Properties with point label, text format, and setpoint color options](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-highlight-setpoint.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=dc3a78c869d08acd0423e3367436b610) The Highlight Setpoint configuration lets you select the point label, display format, and setpoint color * **Point Label** -- select which point to use as the setpoint reference * **Text** -- choose the display format for the highlighted value * **Setpoint color** -- set the color used to highlight the setpoint value on the table #### Zone tool Zone drawings define colored regions on a graphic that change appearance based on aggregated live data from devices within the zone. Click the **Zone Tool** widget, then click on the floor plan to draw the zone outline. Each click places a point that defines a start and end line of the zone boundary. Close the shape to complete the zone. On floor plans, you can also use the zone drawing tool to create [floor plan sections](/products/kode-os/graphics/floor-plans#floor-plan-sections). Sections hide nested markers and zones until a viewer clicks or zooms into that part of the floor. Select a zone to open the Zones Configuration panel on the right. ![Zones Configuration panel with Properties, States, Style, and Navigation sections for a selected zone on a floor plan](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-zone-config.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=95c144e979038be28b5fd496b0b89dcf) The Zones Configuration panel defines the zone's data source, states, style, and navigation behavior **Properties** **Kind** `Field` Select the data type for the zone: `Number` for numeric values or `String/Boolean` for enum and boolean points. **Devices** `Field` Select the devices within the zone that drive its color. Only devices placed within the zone's borders can be chosen. **Points** `Field` Choose the common point across all selected devices (for example, room temperature or occupancy status). **Operator** `Field` Determine how multiple device values are combined. For numeric points: `AVG`, `MIN`, `MAX`, `SUM`, or `MED`. For boolean/enum points: `AND` (all values must match) or `OR` (any value triggers). **States** The States section defines how the zone changes color based on live values. Select a `Smart Configuration` to use a pre-built smart marker configuration, or define custom value ranges manually. ![Zone States configuration showing five value ranges with corresponding colors ranging from blue through green to red](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-zone-states.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=b393f0114b046be7ef140b1755f1bb94) Each state maps a value range to a color. The zone changes color as the aggregated value moves between ranges. Click `+ Add state` to define additional ranges. Each state supports comparison operators (`Between`, `Greater than`, `Less than`) with a corresponding color. **Style** **Zone name** `Field` Enter a label to display on the zone. **Default zone color** `Field` Set the fallback color that displays when the zone's value does not match any configured state. **Referenced Space** Use **Referenced Space** to connect a zone drawing to the spaces model: * **Assign Space** -- link the selected zone to an existing space * **Create Space from Zone** -- create a new space record from the zone * **Add more / Remove** -- manage functionally linked devices in the referenced space context ![Zone configuration panel showing Referenced Space with Assign Space and Create Space from Zone buttons and device link options](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-referenced-space-options.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=edeb467af9b4cbbba9fa870f9d4dd71f) Referenced Space options on a selected zone **Navigation** Make the zone interactive by selecting `Insert URL` to link to an external page, or `Link a Device, Area or System` to navigate to a Cloud BMS resource when clicked. > [!NOTE] > > The current version supports one point reference per zone. Each zone evaluates a single point type across the devices within its borders. #### Pivot table Pivot tables display devices as rows and points as columns, creating a matrix view of multiple devices side by side. Drag the **Pivot Table** widget onto the canvas. The creation flow has two steps: ![Add new Pivot Table dialog showing a searchable device list with checkboxes to select devices as rows, with a 50 device limit](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-pivot-table-devices.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=d8aaefc9cb7ca527d5fc9a5cf046497b) Select up to 50 devices to include as rows in the pivot table 1. **Select devices** -- choose up to 50 devices to appear as rows. Use the search bar or filter by type. Check `Create without points` to add devices with no point columns. 2. **Select points** -- choose up to 10 points to appear as columns. The number next to each point indicates how many of the selected devices have that point. **Pivot table style** Select a pivot table on the canvas to open the Pivot Table Style panel: * **Layout** -- choose a layout preset (`Default` or alignment variants) * **Borders** -- toggle border visibility and customize border appearance * **Devices > Column Header** -- configure the font size, bold formatting, text color, `Cell color`, and `Wrap text` for the device name column header * **Devices > Column** -- configure the font size, bold formatting, text color, and `Cell color` for device name cells * **Points > Column Header** -- configure the same style properties for the point column headers * **Points > Column** -- configure style properties for point value cells ### Uploads Upload images from your computer to use as backgrounds, overlays, or visual elements on the graphic. Click `+` to add a new file. ### Drawings A library of pre-built drawing components provided by Cloud BMS for building system schematics and graphic layouts. Components are organized by category (sensors, fans, cooling and heating coils, valves, pipes, and more). Expand a category to browse, then drag components onto the canvas. * Resize and rotate each component * Group components into sub-assemblies for easier manipulation * Creating the drawing is separate from placing markers, which you do as a second step ## Layers Layers organize a graphic into multiple views so that a single graphic can present different data sets without visual clutter. Each layer displays its own set of markers, tables, and points. Switch between layers using the tabs in the bottom toolbar. Click `+ Add Layer` to create a new layer. ![Create Layer dialog with fields for layer configuration, layer name, icon selection, and an option to import devices from another layer](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-create-layer.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=5d0f94348ac37ab633b5817307c9b725) The Create Layer dialog configures the layer name, icon, and optional layer configuration preset **Layer Configuration** `Field` Select a pre-configured layer preset from the [Graphic Tool settings](#layer-settings). Presets auto-map device types and points when you drop devices onto the layer. **Layer name** `Field` Enter a descriptive name for the layer (for example, `Temperature` or `Occupancy`). **Import devices from another layer** `Toggle` Copy device placements from an existing layer into the new one. This avoids re-placing devices that share the same physical locations. To reorder layers, click the `Arrange Layers` button in the bottom toolbar. Drag layers into the desired sequence. ![Layer Arrangement panel showing a draggable list of layers including Default, Devices, Temperature, and Occupancy](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-layer-arrangement.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=b67b16ca34d3f8178b60b9618fad2864) The Layer Arrangement panel lets you reorder layers by dragging them into position Layers apply to floor plans, device graphics, and system graphics. ## Overlays Overlays are visual elements that render on top of the floor plan and can be toggled on or off independently from layers. Use overlays to display infrastructure layouts such as ductwork, piping, or wiring paths without cluttering the primary graphic view. ![Floor plan with blue and purple duct overlays showing supply and return duct routing across the building](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-overlay-ducts.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=4266768ff50416834e3907e062e76747) A duct overlay rendered on top of a floor plan, showing supply and return duct paths in separate colors Click `+ Add Overlay` in the bottom toolbar to create a new overlay. Each overlay supports its own set of visual elements from the `Elements` tab. Toggle overlay visibility using the eye icon in the bottom toolbar. ## Keyboard shortcuts | Shortcut | Action | | - | - | | Ctrl + Z | Undo | | Ctrl + Y | Redo | | Ctrl + C | Copy | | Ctrl + V | Paste | | Delete | Delete selected object | | Ctrl + A | Select all | | Ctrl + D | Duplicate | ## Settings Access the Graphic Tool settings by clicking `Settings` in the lower left corner of the Graphic Tool module. The settings page has four tabs: `Layers`, `Smart Markers`, `Icons`, and `Files`. ### Layers Pre-configure layers so that devices placed on a graphic automatically attach the correct points. Click `+` next to the search bar to create a new layer configuration. ![Layer settings page showing a configured layer with name, category, device type, smart configuration, and preferences for marker display](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-layers.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=a15ecaac84a0211f21c0a35b662bf701) A configured layer showing the name, category, device type, smart configuration, and display preferences **Name** `Field` Enter a name for the layer configuration. **Category** `Field` Select a category (for example, `Floor Plan`) to organize the layer. **Device Type** `Field` Select the device types and points that this layer targets. Click `Edit` to configure which devices and points auto-attach when you drop a device onto a graphic using this layer. **Smart Configuration** `Field` Choose a smart marker configuration to apply automatically to markers placed on this layer. Click `Edit` to select a configuration. **Preferences** Set display preferences for markers placed on this layer: * **Show smart marker icons when placed** -- display only the icon * **Show smart marker values when placed** -- display only the value * **Show smart marker icons and values when placed** -- display both ![Empty layer configuration form with fields for name, category, device type, smart configuration, and display preferences](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-layers-create.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=665117794f8bc22c119fbf1821525130) The Create configuration form with empty fields for setting up a new layer > [!TIP] > > Layer configurations significantly speed up graphic creation. When a device type and smart configuration are set, dropping a device onto the graphic automatically adds the mapped point as a marker without manual point selection. ### Smart markers Create and manage smart marker configurations. Click `+` to create a new configuration and choose between two types: `Static Ranges` or `Difference from Setpoint`. ![Smart Markers settings showing Static Ranges and Difference from Setpoint options, a category sidebar with configurations, and value range definitions with colors](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-smart-markers.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=24505dd7f150621838033e75e856a1d9) Smart Markers settings with the configuration type selector, category list, and value range definitions **Static Ranges** define fixed value ranges with corresponding colors and icons. **Category** `Field` Select a category to organize the configuration (for example, `Air Quality` or `Temperature`). **Kind** `Field` Choose `Number` or `String/Boolean` depending on the point data type. **Unit** `Field` Set the unit of measurement (for example, `percent` or `°F`). Define value ranges by clicking `+` next to each row. Each range has a label, `From` and `To` boundaries, an icon, and a color. Click the edit icon next to a label to rename it. **Difference from Setpoint** markers compare current values against the device setpoint. ![New Group Setpoint dialog with fields for name, category, device type, dual setpoints, setpoint field, tolerance, and within/outside setpoint color configuration](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-setpoint.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=68620a9e58f10a7c123787ef639c37ea) The Difference from Setpoint configuration defines the device type, setpoint field, tolerance, and within/outside setpoint colors **Device Type** `Field` Select the device type this configuration applies to (for example, `ahu`). **Dual Setpoints** `Toggle` Enable dual setpoints for devices with separate heating and cooling modes. **Setpoint** `Field` Select the setpoint field to compare against (for example, `zone_air_temperature_setpoint`). **Calculate in percentage** `Toggle` Express the tolerated deviation as a percentage instead of an absolute value. **Tolerated value** `Field` Set the acceptable deviation from the setpoint. Values within this range display the `Within Setpoints` color; values outside display the `Outside Setpoints` color. **Show Delta on Smart Marker** `Toggle` Display the difference between the current value and the setpoint on the marker. Pre-configured smart markers based on common use cases are available in the library. Use the three-dot menu next to any configuration to duplicate it or move it to a different category. ### Icons The Icons tab provides two icon sources for use in graphics. ![Icons settings showing the KODE Library with a searchable grid of built-in icons including AHU Filter, Air Quality, Alarm, Battery, CO2, and more](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-icons-library.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=0fc1d7ac16d026e56b3ef081aaf43a93) The KODE Library contains built-in icons for common building equipment and sensors * **Kode Library** -- browse and search the built-in icon library with icons for common building equipment types * **Uploaded** -- view and manage custom icons uploaded by your organization. Click `Upload Icon` to add a new icon. Custom icons must be SVG or PNG format with a maximum size of 2 MB. ![Icons settings showing the Uploaded section with custom organization icons and an Upload Icon button](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-icons-uploaded.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=219d2b36010c90497c2fdbffd4031bff) The Uploaded section shows custom icons added by your organization with options to delete them ### Files Manage uploaded graphic files used across floor plans, devices, and systems. Files are organized by category: `Floor Plans`, `Devices`, and `Systems`. ![Files settings showing the Floor Plans category with a list of uploaded files, file sizes, and creation dates](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-settings-files.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=0694243cb08bd859c264cfcd2aa3948a) The Files tab lists uploaded graphic files with file name, size, and creation date Click `Upload` to add a new file. Use the search bar to find existing files. > [!NOTE] > > The recommended file format for graphic backgrounds is PNG with a maximum width of 1920px and maximum height of 1080px. ## Next steps > [card] [Floor plan graphics](/products/kode-os/graphics/floor-plans) > > Place devices on floor plans with smart markers, zones, and tables. > [card] [System graphics](/products/kode-os/graphics/system-graphics) > > Build system schematics from the drawing component library. > [card] [Device graphics](/products/kode-os/graphics/device-graphics) > > Create equipment-level visuals with live point data. # System graphics Source: https://docs.kodelabs.com/products/kode-os/graphics/system-graphics Create and interact with schematic diagrams of building systems with live data overlays in Cloud BMS. > [!NOTE] > > System graphics are a building-level feature. Select a building from the [sites list](/products/kode-os/sites-and-map) to access system graphics through the Systems module or Graphic Tool. System graphics are schematic or P\&ID-style visual diagrams of building systems with live data overlaid on equipment components. They provide a visual representation of how equipment is connected and operating, making it possible to monitor system health and diagnose issues at a glance. ## Use cases System graphics are commonly used for: * **AHU schematics** showing airflow paths, damper positions, fan speeds, and temperature readings * **Chiller plant diagrams** displaying chiller status, pump operation, and water temperatures * **Electrical one-line diagrams** with live power readings and breaker status * **Boiler system layouts** with supply and return temperatures, valve positions, and firing status ## Navigate to system graphics You can access system graphics from two entry points: * **Graphics module** -- click `Graphics` in the left sidebar and select the `Systems` tab to view existing system graphics * **Systems module** -- click `Systems` in the left sidebar, select a system, and switch to the Graphics view ![Graphics module showing the Systems tab with a System Floor graphic card for HWS, a search bar, and a New Graphic button](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-systems-list.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=f1b03e50400af30cb467cf653685c27c) The Graphics module Systems tab lists existing system graphics with options to search and create new ones ## Create a system graphic Before creating a system graphic, make sure you have [created a system](/products/kode-os/systems#create-a-system) in the Systems module. The graphic must be linked to an existing system. **1. Open the new graphic dialog** Navigate to `Graphics` in the left sidebar, select the `Systems` tab, and click `New Graphic`. You can also create a system graphic from within a system by navigating to the Graphics view and clicking `+ Create New`. **2. Configure the graphic details** Enter the graphic name, select the system to link it to, and add an optional description. You can also upload a system file (such as a P\&ID drawing) as a background by dragging and dropping or browsing for a file. ![New System Graphic dialog with fields for Graphic Name, System dropdown, Description, and a System File drag-and-drop upload area](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-new-system-graphic.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=41f0a1a30ff4700668dc3b2fd1e4a844) The New System Graphic dialog collects the graphic name, system assignment, description, and an optional system file upload **Graphic Name** `Field` Enter a descriptive name for the system graphic (for example, `Hot Water System`). **System** `Field` Select the system this graphic belongs to. The dropdown lists all systems configured in the [Systems module](/products/kode-os/systems#create-a-system). **Description** `Field` Add an optional description of the graphic's purpose. **System File** `Field` Upload a background image or P\&ID drawing. Drag and drop a file, click `Browse files` to upload from your computer, or click `Browse from files` to select from previously uploaded files. **3. Open the Graphic Tool** Click `Done` to create the graphic and open it in the [Graphic Tool](/products/kode-os/graphics/graphic-tool) editor. ## Build the system schematic The Graphic Tool editor provides three tabs for building system graphics: Devices, Elements, and Basics. ### Devices tab The `Devices` tab lists all devices and points associated with the linked system. A green checkmark with a number indicates how many points from that device are already placed on the graphic. ![Graphic Tool editor showing the Devices tab with a list of devices including AHU\_1 through FCU\_208, and a system piping schematic on the canvas](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-devices-tab.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=d25b1718b8ee0e113b2e2a97a768928c) The Devices tab shows system devices with their points, and the canvas displays the system schematic Expand a device to see its points with current values. Drag a point onto the canvas to place a marker at the corresponding location on the schematic. Use the search, sort, and filter icons at the top of the device list to find specific devices or points. ### Marker style When you select a placed marker, the right panel displays style options for customizing its appearance. ![Graphic Tool showing FCU208 device expanded with point values on the left, system schematic with On status markers in the center, and marker style options including Alignment, Layout, Container, Borders, and Header on the right](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-marker-style.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=e22aa08db29daadce9a728718a545841) Selecting a marker reveals alignment, layout, container, border, and header styling options in the right panel The marker style panel includes: * **Alignment** -- position the marker relative to other selected elements * **Layout** -- choose the display layout (Default, or horizontal/vertical alignment options) * **Container** -- set the fill color and choose rounded or square corners * **Borders** -- toggle border visibility and style * **Header** -- show or hide the device name header, set font size, and customize the header color For detailed marker configuration including smart markers and color-coded ranges, see the [Graphic Tool](/products/kode-os/graphics/graphic-tool#devices-tab) documentation. ### Elements tab The `Elements` tab displays reusable elements that have been saved to the graphic's element library. Use this tab to search, select, and style placed elements. Selecting an element from the list highlights it on the canvas and opens the Marker Style panel on the right. ![Graphic Tool showing the Elements tab with FCU208 entries and a table element listed, the system schematic on the canvas, and the Marker Style panel with Layout, Container, Borders, Header, and Pointer options](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-elements-markers.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=ae1322e27aef2d08a353101cb7d56db2) The Elements tab lists placed elements with options to search and style them using the Marker Style panel ### Basics tab The `Basics` tab contains shapes, device widgets, uploads, and built-in drawings for constructing system schematics. ![Graphic Tool showing the Basics tab with Uploads section, and Drawings organized by category including North Sign, AHU Elements with Sensor and Fan subcategories, Cooling and Heating Coil, and Electrical Heater](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-basics-tab.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=9fac8771d8262fa68da186ecae8dc5df) The Basics tab provides built-in drawing components organized by equipment category The `Drawings` section contains pre-built equipment components organized by category: * **North Sign** -- directional indicator * **AHU** -- air handling unit elements including sensors, fans, cooling and heating coils, and electrical heaters * Additional equipment categories for valves, pipes, pumps, and other system parts Drag and drop components onto the canvas to build the schematic. See the [Graphic Tool Basics tab](/products/kode-os/graphics/graphic-tool#basics-tab) for details on shapes, device widgets, and uploads. ## System layers Layers organize the system graphic into multiple views, reducing clutter on complex schematics. Click `+ Add Layer` at the bottom right of the canvas to create a new layer. ![Create Layer dialog with fields for Layer name, icon selector showing No icon selected, and an Import devices from another layer checkbox](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-create-layer.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=e58dc66e7777d99e2cf21d6c59fceb3b) The Create Layer dialog lets you name the layer, assign an icon, and optionally import devices from another layer **Layer name** `Field` Enter a descriptive name for the layer. **Icon** `Field` Select an icon to represent the layer in the layer selector bar. **Import devices from another layer** `Toggle` Copy device placements from an existing layer to use as a starting point for the new layer. * The **Base Layer** shows critical operating parameters * Additional layers contain supplementary data, tables, system markers linking to related systems, and diagnostic points > [!TIP] > > Use [layer configurations](/products/kode-os/graphics/graphic-tool#settings) in the Graphic Tool settings to pre-map device types and points to layers. Dropping a device onto a layer with a configuration automatically adds the correct point marker. ## Overlays Overlays are additional visual layers that you can toggle on and off over the system graphic. Use overlays to display supplementary information such as duct routes, piping paths, or wiring diagrams without cluttering the main schematic. Click `+ Add Overlay` at the bottom right of the canvas to create an overlay. ![Graphic Tool showing the system schematic with the Base Layer selector, Add Layer, and Add Overlay options at the bottom of the canvas](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-system-elements-tab.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=caf47c227da3a28ea952f8203514dccc) The canvas bottom bar shows the Base Layer selector alongside Add Layer and Add Overlay options For more details on overlay configuration, see the [Graphic Tool overlays](/products/kode-os/graphics/graphic-tool#overlays) documentation. ## System markers System markers act as navigation links between system graphics. They allow users to jump between related schematics or navigate from a floor plan directly to a system graphic. While editing a graphic, switch from `Devices` to `Systems` in the left-hand elements menu. Drag and drop a system onto the canvas to create a clickable navigation marker. ## Read live data on a system graphic System graphics overlay real-time point values directly on the schematic: * **Temperature readings** near corresponding sensors * **Valve positions** as percentage values next to valve symbols * **Fan and pump status** indicators showing running, stopped, or fault states * **Pressure and flow readings** at their measurement locations ## Identify alarms and faults Devices and points on the system graphic use color-coded status indicators: | State | Indicator | Meaning | | - | - | - | | **Alarm** | Red icon | Active alarm condition | | **Down** | Grey icon | Device or point is not communicating | | **Fault** | Orange icon | Fault condition detected | | **Stale** | Yellow icon | Value has not updated within the expected interval | | **Overridden** | Purple icon | Point is under manual override | Click any device on the graphic to open its details or access the command window for writable points. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ## Delete a system graphic To remove a system graphic, click the three-dot menu on the graphic card in the Systems list and select `Delete`. ![Graphics module Systems tab showing two system graphic cards with a three-dot menu expanded on Hot Water System showing Edit and Delete options](https://mintcdn.com/kodelabs/XLzbYkNX6LnaxcLs/images/kode-os/graphics/kode-os-graphics-systems-list-menu.png?fit=max\&auto=format\&n=XLzbYkNX6LnaxcLs\&q=85\&s=5213c6cc0e85a4932d627e24acb0519f) The three-dot menu on each graphic card provides Edit and Delete options Confirm the deletion when prompted by clicking `Yes, delete`. ![Delete Graphic confirmation dialog with Cancel and Yes delete buttons](https://mintcdn.com/kodelabs/1vjgtnWf-CUbC2z9/images/kode-os/graphics/kode-os-graphics-delete-confirm.png?fit=max\&auto=format\&n=1vjgtnWf-CUbC2z9\&q=85\&s=8c41962af75b86dcbfb897e728da3217) The confirmation dialog asks you to verify before deleting the graphic > [!WARNING] > > Deleting a system graphic removes the visual layout and marker configuration. The devices and points themselves are not affected. ## Next steps > [card] [Graphic Tool](/products/kode-os/graphics/graphic-tool) > > Configure smart markers, zones, layers, and global settings. > [card] [Device graphics](/products/kode-os/graphics/device-graphics) > > Build equipment-level visuals with live point data. # Mass write Source: https://docs.kodelabs.com/products/kode-os/mass-write Write multiple points and update multiple schedules simultaneously across buildings or an entire portfolio. > [!NOTE] > > Mass write is available at the portfolio level and at the building level. Portfolio workflows use the **Mass Write** module. Building-level workflows use **Mass Write Points** in the Points module or **Mass Write Schedules** in the Schedules module. Mass write allows you to modify multiple points or schedules in a single operation across one or more buildings. Instead of editing each point or schedule individually, you select targets in bulk, configure the changes, and execute them as a tracked job. At the portfolio level, the **Mass Write** module uses a left-side menu to switch between **Points** and **Schedules**. ![Mass Write Points main page with Schedules and Points tabs and a job list table](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/mass-write-points-list.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5a75e06f36903218412d1d9a53eae505) The Mass Write Points page showing previous jobs with their status, building count, and reason ## Enable mass write access Mass write permissions must be activated on the user's KODE OS role before the module appears. **1. Open role settings** Navigate to `Launchpad` > `Apps` > `Cloud BMS` > `Roles` and select the role you want to update. **2. Enable permissions** Edit the role and enable the following permissions: | Permission | Purpose | | - | - | | `Get points latest configs` | Enables the Mass Write module in the portfolio view | | `Initiate points mass write` | Allows the user to execute a mass points write | | `Schedule Mass Write (Read)` | Enables viewing mass write schedules | | `Schedule Mass Write (Write)` | Allows the user to execute a mass schedule write | **3. Save the role** Click `Save`. Users with this role see the `Mass Write` module in the portfolio view. > [!WARNING] > > Only Launchpad administrators can update role permissions. If you do not have admin access, submit a support ticket to request the change. ## Mass write points Use mass write points to send values to multiple writable points across buildings simultaneously. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). Common scenarios include: * Adjusting temperature setpoints seasonally across the portfolio * Releasing overrides so devices follow their schedules overnight * Responding to peak demand by reducing setpoints by a set increment * Disabling specific devices or systems during scheduled maintenance ### Access mass write points > [tab] Portfolio level > > 1. From the portfolio view, open **`Mass Write`**. > 2. Click **`Points`** in the left-side menu. > 3. Click **`Write Points`** to start a new job or open an existing job from the list. > [tab] Building level > > 1. Select a building from the [sites list](/products/kode-os/sites-and-map). > 2. Open **`Points`** in the left navigation. > 3. Click **`Mass Write Points`** in the left sub-menu. > > See [Mass write points](/products/kode-os/points/points#mass-write-points) in the Points article for the building-level workflow and screenshots. ### Selection and search Only writable points appear in the mass write list. Points are not selected by default — select targets explicitly with row checkboxes. Use **`Select all`** to include every point across all pages. After **`Select all`**, deselect individual exceptions as needed. Use **Filters** to narrow the list by point type, canonical type, area, ontology field, data source type, and other attributes. To find non-templated points, set **Ontology Field** to **Not Assigned**. Search supports three match modes — **Starts with**, **Contains**, and **Exact** — across these fields: | Field | Description | | - | - | | **Point Name** | Display or raw point name | | **Path** | Point path in the data source | | **Ontology Field** | Normalized ontology field name | | **Device Name** | Device that owns the point | Toggle between **List** and **Grouped** view in the upper right. #### Grouped selection Grouped view simplifies selection for large point sets, especially non-templated points. In grouped mode: * Points are grouped by name and kind. * Each group shows the group name, point count, and device count. * Expand a group to review the underlying point list with the same columns as the standard table. * Select entire groups. You cannot include or exclude individual points inside a group. Filters still apply to the full list before grouping. Grouping does not replace filters. > [!WARNING] > > When writing very large point sets, confirm that target data sources can handle the write volume. This matters when many buildings share a single data source. ### Write points **1. Open mass write points** From the portfolio view, navigate to **`Mass Write`**, click **`Points`** in the left-side menu, then click **`Write Points`**. **2. Filter buildings** Use the **Filters** panel on the left to select one or more buildings. You can filter by country, state, city, or building name. Click **`Apply`** to load the available points. > [!NOTE] > > There is no limit to the number of sites you can select in a single job. **3. Filter and search points** Use **Filters** to narrow the point list. Set **Ontology Field** to **Not Assigned** when you need non-templated points. Use search with **Starts with**, **Contains**, or **Exact** match modes. **4. Select points** Choose targets in **List** or **Grouped** view. Use row checkboxes or group checkboxes, or **`Select all`** across pages. Deselect any exceptions. ![Select Points page showing filter panel, grouped points table with point and device counts, and List and Grouped view toggle](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/select-points.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=49d86d66d1a91252a4b6867346dcd223) The Select Points page with building filters on the left and the point list on the right Click **`Continue to Set Values`** when the selection is final. > [!WARNING] > > You cannot remove points from the list in later steps. Verify your selection before continuing. **5. Configure the job** Enter a **Name**, **Reason Type**, and **Reason Description**. These fields identify the job in the tracking history. Points are grouped automatically by ontology field, unit, and accepted values or facets. You set values per group, not per individual point. Click the blue count next to a group name to see which points belong to it. **6. Set values for each group** Expand a group and configure: | Field | Description | | - | - | | **Priority** | Write priority: **Override**, **Auto**, **Set**, or **Release** | | **Value** | Value to write to every point in the group. Negative values are supported for numeric points. | | **Duration** | How long the value persists before reverting. Check **Permanent** to keep the value until released. | Click **`Save`** for each group. Color highlights indicate missing information. ![Set Values page with job name, reason type, and point groups configured with Override priority and values](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/set-values.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=7560cc203b33fb57f2cd8309bf5ff0d8) The Set Values page showing job details and point groups with priority, value, and duration settings **7. Execute the job** After saving all groups, click `Execute`. A confirmation dialog warns that changes are not reversible. Review your point selection, then click `Proceed` to start the write operation. ![Caution dialog warning that changes are not reversible with Go Back and Proceed buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/caution-dialog.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=66de851d95eda7cdaae7fced619b7016) The confirmation dialog requires you to verify your selection before executing Cloud BMS begins writing values to every selected point. You are redirected to the job details page. ### Track job progress The job details page shows: * Creator and creation time * Total number of points processed * Success and failure counts per group ![Mass Write Point job details page showing completed status, point groups with success counts, and activity log](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/job-details.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=3e6d93412fc97a720faf63a6fe276bf8) The job details page displays status, point groups, and an activity log of the write operation Click the blue counts to view individual points within each group and their write results. Completed jobs remain listed on the main **Mass Write** page for future reference. Use the **`Export`** button to download job results as CSV. Enter a **File Name**, choose which **Columns** to include, then click **`Export`**. The CSV export includes **Building ID**, **Building Name**, **Device ID**, **Device Name**, **Name**, **Field**, **Priority**, **Value**, **Duration**, **Status**, and **Failed Reason**. ![Export dialog with File Name and Columns fields](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/export-dialog.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b9507bbd28e538a614cbbaf2532cfc31) Export job results with a custom file name and column selection From job details, use the three-dot menu to: | Action | Behavior | | - | - | | **Edit Details** | Update the job name or description | | **Re-run Job** | Start a new run. Change the point selection and write configuration before executing | | **Retry Job with failed points** | Re-execute immediately for failed points only | ![Job details three-dot menu showing Edit Details, Re-run Job, and Retry Job with failed points options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/job-actions-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=f5f120026210eea3f374bdb38256e184) The job actions menu provides options to edit, re-run, or retry failed points ## Mass write schedules Use mass write schedules to update multiple schedules at once. Common scenarios include: * Changing start or end times across schedules for seasonal daylight shifts * Updating operational hours based on new tenant contracts * Adding holiday special events to multiple schedules simultaneously * Implementing building-wide or portfolio-wide schedule changes after emergencies ### Access mass write schedules > [tab] Portfolio level > > 1. From the portfolio view, open **`Mass Write`**. > 2. Click **`Schedules`** in the left-side menu. > 3. Click **`Write Schedules`** to start a new job or open an existing job from the list. > [tab] Building level > > 1. Select a building from the [sites list](/products/kode-os/sites-and-map). > 2. Open **`Schedules`** in the left navigation. > 3. Click the three-dot menu in the top right. > 4. Click **`Mass Write Schedules`**. > > See [Schedules](/products/kode-os/schedules) for building-level schedule management. ### Selection and search Every weekly schedule (excluding calendar schedules) appears in the list based on your filters. Schedules are not selected by default — select targets explicitly with row checkboxes. Use **`Select all`** to include every schedule across all pages. After **`Select all`**, deselect individual exceptions as needed. Use **Filters** to narrow by **Kind**, **Current Status**, or **Data Source**. Use the search bar to find schedules by name. Toggle between **List** and **Grouped** view in the upper right. #### Grouped selection Grouped view simplifies selection for large schedule sets. In grouped mode: * Schedules are grouped by name and kind. * Each group shows the group name and schedule count. * Expand a group to review the underlying schedule list with the same columns as the standard table. * Select entire groups. You cannot include or exclude individual schedules inside a group. Filters still apply to the full list before grouping. Grouping does not replace filters. > [!WARNING] > > When writing very large schedule sets, confirm that target data sources can handle the write volume. This matters when many buildings share a single data source. ### Write schedules **1. Open mass write schedules** From the portfolio view, navigate to **`Mass Write`**, click **`Schedules`** in the left-side menu, then click **`Write Schedules`**. **2. Filter buildings** Use the **Filters** panel to select one or more buildings by country, state, city, or building name. Click **`Apply`** to load the available schedules. **3. Filter and search schedules** Use **Filters** to narrow the schedule list. Use the search bar to find schedules by name. **4. Select schedules** Choose targets in **List** or **Grouped** view. Use row checkboxes or group checkboxes, or **`Select all`** across pages. Deselect any exceptions. ![Select Schedules page showing filter panel with building, address, and identifier filters, and a schedule list with name, building, data source, status, and kind columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/select-schedules.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=e538d82619550ee870cb6f0a10b4118a) The Select Schedules page with building filters on the left and the schedule list on the right The header updates to show the total count of selected schedules. ![Select Schedules page with one schedule selected, showing the selection count in the header](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/select-schedules-selected.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=37dc0d2c4d124823d3d08e2799e444fa) Selected schedules are highlighted and the header shows the selection count Click **`Continue to Set Values`** when the selection is final. > [!WARNING] > > You cannot remove schedules from the list in later steps. Verify your selection before continuing. **5. Configure the job** Enter a **job name**, then choose the schedule type and update type. **Schedule type options** | Option | Behavior | | - | - | | **Weekly** | Updates only the weekly time slots on the selected schedules | | **Special Events** | Adds only special events to the selected schedules | | **Both** | Updates weekly time slots and adds special events (you must configure both) | If you choose Weekly, existing special events remain untouched. If you choose Special Events, existing weekly time slots remain untouched. **Update type options** | Option | Behavior | | - | - | | **Append** | Adds the new time slots or special events on top of existing ones without removing current entries | | **Replace** | Replaces existing weekly time slots, special events, or both on all selected schedules with the values you configure here | ![Append update type tooltip explaining it adds timeslots without modifying blank days or existing special events](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/update-type-append.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=503d7abad3d44f196aa466a1d06aa27d) Append adds time slots without modifying existing schedules ![Replace update type tooltip warning that every selected schedule will be replaced and blank days will be deleted](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/update-type-replace.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=c81e4860f8afcd94b78d57b6163712f1) Replace overwrites selected schedules entirely — use with caution > [!WARNING] > > Use Replace with caution. Every selected schedule is replaced exactly with the schedule created here. Days left blank and existing special events are deleted. If you are adding special events, choose a **priority** (Top or Bottom). This determines whether new events take precedence over or defer to existing events on the same date. **6. Create the temporary schedule** A weekly schedule calendar editor appears based on your selection. Click a day to open a context menu with options to **`Create Event`**, **`All Day Event`**, or **`Clear Week`**. Define the start and end times for each period. Timeslot creation and value assignment are separate steps, but both happen on the same page. Values appear after you click into a timeslot. Side panels open automatically to guide the next step, especially for special events. ![Set Values page showing weekly schedule calendar with Create Event, All Day Event, and Clear Week context menu](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/schedule-calendar-editor.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=dbec84230f284fdd49115c92506d5a89) The weekly schedule editor with a context menu to create time slots * If the update type is **Append**, these time slots are added alongside existing ones * If the update type is **Replace**, all existing time slots are replaced with the ones you define here * Days left blank are deleted from the selected schedules For special events, create each event and define its time slot using the same workflow as individual schedule special events. **7. Set values for time slots** Click a time slot in the weekly schedule or a special event to assign values. The left panel shows all schedule groups with their facet values. Schedules are grouped by type (Boolean, Enum, Numeric, String) and facets. ![Set Values page with a time slot created on Monday and the left panel showing schedule groups with value options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/schedule-set-values.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=4f3df2dc407200d08995a67ec66b0233) Click a time slot on the calendar to reveal the value assignment panel on the left Pick one value for each group per time slot. Use `Apply to all` to assign the same values across every time slot in the weekly schedule. Repeat for special events if applicable. Click `Save` at the bottom of the left panel. ![Value selection panel showing false, true, and Null options with Apply to all checkbox and Save button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/schedule-value-panel.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=9dc986a621d733e7dabb1a1d4910eb4c) Select a value for each schedule group and click Save **8. Execute the job** Click `Save` at the top right (the button remains disabled until all time slots have assigned values). Cloud BMS updates every selected schedule and redirects you to the job details page. > [!WARNING] > > Verify that only the intended schedules are selected. Changes are not revertible after execution. ### Track schedule job progress The job details page shows the status, timestamp, schedule type, update type, and success and failure counts per group. The bottom section displays a preview of the weekly schedule with the applied time slots and values. An activity log tracks the execution history. ![Schedule job details page showing completed status, schedule groups, weekly schedule preview with applied time slots, and activity log](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/schedule-job-details.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=de09320c29451ddf47f04feeb043569c) The schedule job details page shows group results and a preview of the applied weekly schedule Click the blue counts to view individual schedules and their results. Completed jobs remain listed on the main **Mass Write** page. Use the **`Export`** button to download job results as CSV. Enter a **File Name**, choose which **Columns** to include, then click **`Export`**. The CSV export includes **Building ID**, **Building Name**, **Datasource ID**, **Datasource Name**, **Name**, **Type**, **Kind**, **Connector Type**, daily updates for **Monday** through **Sunday** when a weekly schedule is updated, **Special Events**, **Status**, and **Failed Reason**. From job details, use the three-dot menu to: | Action | Behavior | | - | - | | **Edit Details** | Update the job name or description | | **Re-run Job** | Start a new run. Change the schedule selection and configuration before executing | | **Retry Job with failed schedules** | Re-execute immediately for failed schedules only | ## Mass write schedules with sheet For scenarios where each schedule requires different times or effective dates, you can import updates from a spreadsheet instead of configuring a single template schedule. **1. Open the import dialog** From the `Write Schedules` flow, click the `Import Schedules with Sheet` button at the bottom of the left filter panel. A dialog opens with three steps: download the template, fill it out, and upload it. ![Import Schedules with Sheet dialog showing Download Template link, fill-in instructions, and a drag-to-upload area](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/mass-write/import-schedules-sheet.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=ba9ccbf46b6a1aba1c0bd0581ab63cf2) The Import Schedules with Sheet dialog guides you through downloading a template, filling it out, and uploading it **2. Download the template** Click `Download Template` in the dialog. The Excel template contains column headers for all required fields. **3. Fill out the template** Complete the following columns for each row: **Required sheet columns** | Column | Format | Description | | - | - | - | | `Identifier` | Numeric (for example, `1210168`) | The store or site ID as defined in Launchpad | | `EffectiveStart` | `MM/DD/YYYY` | The date when the schedule update takes effect (must be in the future) | | `SaturdayStart` through `FridayEnd` | 24-hour time (for example, `07:00`, `22:00`) | Start and end times for each day of the week | All days must have values. Each row can have a different effective date and different daily times. **4. Upload the sheet and execute** Drag the completed file into the upload area or click `Attach or Drag to Upload` in the same dialog. Invalid or missing values are flagged during upload. Click `Import` to proceed. After import, Cloud BMS selects the stores matching the identifiers and displays the available schedules. Select the schedules you want to update and click `Execute`. > [!NOTE] > > The sheet import updates weekly schedule time slots only. Existing special events remain untouched. ## Next steps > [card] [Mass write points](/products/kode-os/points/points#mass-write-points) > > Run mass write points at the building level from the Points module. > [card] [Schedules](/products/kode-os/schedules) > > Set up individual building-level schedules before applying bulk changes. > [card] [Settings](/products/kode-os/settings) > > Configure buildings, roles, and permissions at the portfolio level. # Optimized Start/Stop (OSS) Source: https://docs.kodelabs.com/products/kode-os/oss Use AI-powered Optimized Start/Stop to calculate the optimal HVAC start time, balancing energy savings with occupant comfort. > [!NOTE] > > OSS is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map), then navigate to `OSS` in the left sidebar. You can also access OSS from the `Schedules` module by clicking the `OSS` tab. Optimized Start/Stop (OSS) (Optimized Start/Stop uses machine learning to start HVAC equipment at the latest time that still meets comfort targets by occupancy.) is an AI-powered module that determines the latest possible time to start HVAC equipment while still achieving comfortable zone temperatures by the time occupants arrive. Instead of starting equipment at a fixed early time, OSS uses machine learning to predict the optimal start time based on current building conditions, weather data, and historical performance. ### Benefits * **Energy savings** -- reduces energy consumption by starting HVAC equipment only when needed, avoiding unnecessary early starts * **Occupant comfort** -- ensures spaces reach the target temperature by the time occupants arrive * **Engineering efficiency** -- frees up engineers from manually adjusting start times based on weather and building conditions * **Real-time insights** -- provides daily data on comfort performance and space conditions through the OSS dashboard * **Performance tracking** -- analyzes energy savings and equipment performance over time with historical trend data ## How OSS works The OSS algorithm analyzes three categories of input to calculate the optimal start time: * **Sensor data** -- indoor zone temperatures, setpoints, occupied mode, run status, and fan commands * **Weather data** -- outdoor temperature, humidity, wind speed, and atmospheric pressure * **Building factors** -- insulation characteristics, current conditions, and device performance history Using these inputs, OSS predicts how long the building needs to reach the target temperature and calculates the start time: `OSS Start Time = Schedule Start Time - OSS Prediction` For example, if the schedule start time is 08:00 and OSS predicts 45 minutes to reach the setpoint, OSS starts the equipment at 07:15 instead of the traditional 06:00 fixed start. ![Timeline diagram showing a traditional scheduled start at 6:00 AM without OSS regardless of weather conditions, a variable OSS start window from 6:30 AM to 8:30 AM depending on weather, occupancy time at 8:30 AM, and the shaded area between fixed start and OSS start representing potential energy savings](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-timeline.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=fa3bfcbd13eece396a38952c7af2b40e) OSS calculates a variable start time between the traditional fixed start and occupancy time, creating potential energy savings For accurate predictions, the algorithm requires reliable sensor data. Faulty sensors or insufficient historical data can reduce prediction accuracy. ## Operation modes OSS provides three modes that balance comfort and energy savings differently. Select the operation mode from the OSS page. The status bar at the bottom shows whether OSS is currently active or inactive, with an `Activate` button to enable it. ![Optimized Start Stop page showing Operation Mode with Comfort, Balanced, and Energy Savings options, Balanced selected, an adapter named Test - Point References with 1/1 devices in Floor 2, an edit icon, and OSS is inactive status with Activate button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-main.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b6761d895fbafeecf183f3940516b13f) The OSS page shows the operation mode selector, adapter configurations, and activation status | Mode | Goal | Behavior | | - | - | - | | **Comfort** | Maximum occupant comfort | All zones reach setpoints by the schedule start time. OSS starts the first VAV (Variable Air Volume box — zone-level terminal unit.) and overrides the AHU (Air Handling Unit — primary airside equipment.) simultaneously, with remaining VAVs activating as needed. | | **Balanced** | Comfort and energy savings | Once 25% of VAVs are ready, OSS overrides the AHU and starts them. The remaining VAVs activate progressively to reach full occupancy by start time. | | **Energy Savings** | Maximum energy efficiency | OSS overrides the AHU and starts the first 50% of VAVs when ready. The rest activate gradually to reach full occupancy by start time. | ## Requirements ### Permissions The following user roles have default permissions to configure OSS: * Super Admin * System Admin * System Integrator * Engineering Manager ### Required points The OSS machine learning model requires these five points on each device: **Zone Air Temperature Sensor** `Sensor` The sensor that measures the zone air temperature for the space you want to optimize. **Zone Air Temperature Cooling Setpoint** `Setpoint` The cooling temperature setpoint for the zone. This may be an effective, occupied, or general zone temperature setpoint depending on how the device is programmed. **Zone Air Temperature Heating Setpoint** `Setpoint` The heating temperature setpoint for the zone. Similar to the cooling setpoint, select the appropriate variant for your device configuration. **Run Status** `Sensor` A point that indicates whether the device is currently on or off. **Occupied Mode** `Control` A writable point that overrides the device between on and off states. At least one `occupied_mode` point must be writable on either the base or reference device. ### Schedule requirements OSS requires a valid schedule configured on the devices. Without a schedule, OSS cannot determine when occupancy starts or control equipment start times. > [!WARNING] > > Schedules should not be configured so that starting one device (for example, an AHU) automatically enables its downstream devices (for example, VAVs). Each device must have its own independent schedule for OSS to control them individually. ### Data requirements For accurate predictions, OSS requires at least 15 to 20 devices with at least 15 days of valid historical data. The `occupied_mode` and `run_status` points must show regular on/off switching patterns during this period. ## Supported HVAC architectures OSS supports multiple HVAC system configurations: * **VAV - AHU** -- variable air volume boxes controlled by an air handling unit * **VAV - AHU - AHU** -- cascaded AHU configurations * **FCU** -- fan coil units operating independently * **AHU** -- standalone air handling units ## Configure an OSS adapter The OSS adapter (An adapter binds devices and points to the OSS algorithm for one building configuration.) specifies which devices to optimize and which points to use for control. Each building requires its own adapter configuration. ### Create a new adapter **1. Open the adapter page** Navigate to `OSS` from the building sidebar. Click `Adapters` in the upper right to view the list of configured adapters. ![OSS Adapters page showing three adapters: VAV - AHU with Setpoint, testf, and test, with columns for Name, Description, Possible Configs, and Configs Included](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapters-list.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=0adc1b2b8973c21eba847b8cf43d1609) The OSS Adapters page lists all adapters with their description, possible configs, and configs included Click `Add OSS Adapter` to expand the dropdown with two options: ![Add OSS Adapter dropdown showing Add from existing and Add new adapter options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-add-adapter-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=06ae0bcb793c261f6b71315c65bc6775) The Add OSS Adapter dropdown provides options to add from an existing template or create a new adapter * **Add from existing** -- use a pre-built adapter template from the KODE library * **Add new adapter** -- create a custom adapter from scratch Select `Add new adapter` to start the creation wizard. **2. Select devices** Enter a name and description for the adapter. Select the **base device** by choosing its canonical type (for example, `vav` or `fcu`). Click `+ Add Reference` to add a **reference device** if the architecture requires it (for example, an AHU that serves the selected VAVs). ![Add OSS Adapter step 1 Select Devices showing Name field with VAV - AHU with Setpoint, Description field, Base Device set to vav with Edit and delete options, Add Reference button, and Reference Device set to ahu](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapter-select-devices.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b71f4dcec771328b2883b644dd87f7a3) Step 1 configures the adapter name, description, base device, and optional reference device Devices are exclusive to one adapter. Click `Next` to proceed to point mapping. **3. Add points** Map the required points for the base device and reference device. Each point type has an `Edit Points` button to configure the specific point mapping. ![Add OSS Adapter step 2 Add Points showing Base Device section with Zone Air Temperature Sensor, Zone Air Temperature Cooling Setpoint, Zone Air Temperature Heating Setpoint, Run Status, and Occupied Mode points, and Reference Device section with Run Status and Occupied Mode points, each with Edit Points buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapter-add-points.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5e4a117331732bd2610f99a04d0b3c2f) Step 2 lists the required points for the base device and reference device with Edit Points options Click `Edit Points` on a point type to expand it and configure the mapping. Select the point from the device, set the aggregation function if multiple points of the same type exist, and map enum values for on/off or occupied/unoccupied states. ![Add Points step with Zone Air Temperature Sensor expanded showing vav zone\_air\_temperature\_sensor point with avg aggregation, and Reference Device Run Status expanded showing ahu occupied\_mode point with On mapped to Occupied, Off mapped to Unoccupied, and orFunction aggregation](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapter-points-expanded.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=1a8789f4efe01c359ed065663ea7f1c1) Expanded point mappings show the selected point, aggregation function, and enum value configuration > [!NOTE] > > If a device has multiple points of the same type, select an aggregation function (AVG, MIN, MAX, SUM, MED) to combine them. For cooling and heating setpoints, you can configure upper and lower bands that define the acceptable temperature range. **4. Review and verify** The review page has two tabs: * **Completed Devices** -- lists devices that meet all OSS requirements (required points mapped, schedules in place, writable occupied mode) * **Devices With Issues** -- lists devices that need adjustments before OSS can control them ![Step 3 Review and Verify showing 5 Completed Devices tab with VAV\_301, VAV\_308, VAV\_302, VAV\_309, and VAV\_303, each showing zone air temperature sensor values, cooling setpoint, reference device AHU\_3, and run status and occupied mode set to true](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-review-completed.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=6fbdc35cb5812b695a8093935fa7d28e) The Completed Devices tab shows devices with all points mapped and ready for OSS control ![Step 3 Review and Verify showing 35 Devices With Issues tab with VAV devices showing Missing indicators for zone air temperature sensor, reference device, run status, and occupied mode points](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-review-issues.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=750370af662486bb7c2e892024665ce7) The Devices With Issues tab highlights missing points and configurations that need attention Common reasons a device appears under **Devices With Issues**: * Required ontology point fields are not assigned * Occupied Mode is missing or not writable * Required enum values are not mapped for Occupied / Unoccupied interpretation * The device has no schedule point reference * Parent or child device referencing is missing (for example, a VAV without an `isFedBy` AHU) Use this remediation loop until devices move to **Completed Devices**: 1. Fix missing schedule references on the schedule **Point References** page. 2. Add missing device references (for example, `isFedBy`) on the device. 3. Complete ontology field mapping in device modeling. 4. Map enum values for Run Status and Occupied Mode as needed. 5. Return to Review and Verify and select `Refresh` to re-check status. Select the devices you want to include from the Completed Devices tab and click `Save`. > [!WARNING] > > If you save without selecting any Completed devices, the adapter does not create an active device list. **5. Activate OSS** After saving, the OSS Adapters page shows the updated adapter with its possible configs and configs included counts. ![OSS Adapters page showing VAV - AHU with Setpoint adapter with 5 possible configs and 5 configs included, testf with no configs, and test with 4 possible configs and 1 config included](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapters-saved.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=cae36235e086ae4abf57766c3c1b2250) The OSS Adapters page shows the saved adapter with possible and included config counts Navigate back to the OSS page. The adapter appears in the list with the number of devices and area. Click `Activate` in the bottom right corner to enable OSS. ![Optimized Start Stop page showing Weekly Schedule adapter with 5/5 devices in Floor 3 and Test - Point References adapter with 1/1 devices in Floor 2, with OSS is inactive status and Activate button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-main-saved.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=92118bbe59cf5c6823852803a3cde255) The OSS page shows all configured adapters with their device counts and the Activate button A confirmation dialog appears. Click `Confirm` to activate OSS. ![Confirmation dialog asking Are you sure you want to activate OSS with Cancel and Confirm buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-activate-confirm.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=bbb9f418d3fe7c75aac82b575bb353d0) Confirm the activation to enable OSS for the configured adapters OSS begins preparing and the Activity Log tracks the activation progress. Wait for the process to complete. ![Optimized Start Stop page showing a loading spinner with message It may take some time to get ready and Preparing status, with Activity Log showing OSS In progress](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-activating.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=1d3292358976b706a28590c3670f8e6e) OSS shows a preparing state while the algorithm initializes ### Use an existing adapter template KODE Labs provides pre-built adapter templates for common HVAC configurations. Click `Add OSS Adapter` and select `Add from existing` to browse the template library. ![Add Adapter from the library dialog showing three templates: FCU with Zone Air Temperature Setpoint, VAV - AHU with Setpoint, and AHU with Return Air Temperature Setpoint, each with name and description columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-adapter-library.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=22af8601f983529af9064346c048e87b) The adapter library lists pre-built templates for common HVAC configurations Select a template and click `Add from existing`. Steps one and two of the adapter creation process are prefilled from the template. You can modify any prefilled values before saving. ### Edit or delete an adapter To edit an adapter, click the pencil icon next to the schedule name on the OSS page. The Add/remove devices dialog opens, where you can select or deselect devices for the adapter. ![Weekly Schedule Add/remove devices dialog showing five VAV devices (VAV\_301, VAV\_308, VAV\_302, VAV\_309, VAV\_303) all selected with checkboxes, a search field, and Cancel and Save buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-edit-devices.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=428725ff8fce8fc288f0364ac12ff0e9) The Add/remove devices dialog lets you select which devices to include in the adapter To fully reconfigure an adapter (device types, point mappings, or review settings), click the adapter name from the OSS Adapters page to open the adapter creation wizard. To delete an adapter, click the three-dot menu and select the delete icon. ## Schedule best practices for OSS When OSS is active, the schedule start time represents the **target satisfaction time** (when the space should be at the setpoint), not the equipment start time. OSS handles the actual start time calculation. For example, if an office building has occupancy from 08:30 to 17:30, set the schedule start time to 08:30. OSS calculates the optimal equipment start time so that the building reaches the target temperature by 08:30. > [accordion] Schedule configuration guidelines > > **Recommended:** > > * Set the schedule start time to the desired occupancy start > * Ensure each device has its own independent schedule > * Turn off any BAS logic that automatically enables downstream devices when a parent device starts > > **Avoid:** > > * Schedules where starting an AHU automatically enables its connected VAVs > * Cascaded schedules where one schedule triggers another > * Enum schedules with point mappers or switches that control devices ## Key behaviors and limits * OSS requires a schedule to be in place. Without a schedule, OSS cannot override equipment. * If a device is already in occupancy override, OSS does not make additional changes. * If the predicted start time is less than five minutes before the schedule start, the device follows its original schedule. * If a device is already at the setpoint, OSS does not override it. * Devices that are occupied 24/7 cannot be controlled by OSS. * OSS does not operate with schedules that start between 12:00 AM and 3:00 AM. For best results, schedules should start no earlier than 3:00 AM. If a schedule starts at 2:00 AM and OSS predicts a three-hour duration, it may override the device at 2:00 AM, which can lead to accuracy issues. ## Ongoing operations ### End user guidance To ensure smooth building operations with OSS: * **Initial rollout** -- adjust schedules to reflect target occupancy times, set proper temperature and equipment setpoints, and verify lease start and end dates * **Daily monitoring** -- check your inbox for recommended building startup emails from OSS * **Dashboard review** -- review the Daily OSS Dashboard regularly to confirm comfort goals are met, and use the Historical OSS Dashboard to identify outliers and address poor-performing devices or systems ### Deployment checklist Before activating OSS, verify the following: * Schedules are configured in Cloud BMS with proper AHU references * VAV devices have Zone Air Temperature Sensor, Zone Air Temperature Setpoints, and `isFedBy` references to their parent AHU * AHU devices include a writable `Occupied Mode` point * Adapters are configured based on the correct Zone Temperature Setpoint type * Users are trained on schedule adjustments, the OSS algorithm behavior, the control strategy, and dashboard interpretation ## Verify OSS overrides When OSS overrides a point, the point's activity log records the action with `OSS App` as the user and `Oss Start` as the reason. The log entry shows the priority levels and current values at each level, along with the override duration. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ![Occupancy Cmd point activity log showing an OSS App entry dated Dec 29 2025 with reason Oss Start, levels 8 Occupied, 9 Unoccupied, and 17 Occupied, with Actions showing Priority Override, Value True, Duration 30min, and Preventoverwrite True](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-point-activity.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b0e8a802811bac0add3f48e3b0efef98) The point activity log shows OSS override details including priority levels, values, and duration Use the activity log to confirm that OSS is actively controlling a device and to review the override parameters (priority, value, duration). Click `Test Connection` to verify the point connection to the data source. ## OSS dashboard The OSS dashboard monitors device performance and optimization results through Building BI. Once the OSS adapter is activated, all dashboard calculations are enabled automatically except for the Hours Saved metric, which requires manual data submission. The dashboard shows data only for devices configured with OSS that were running for the specified day or time period. Two dashboard templates are available in Building BI: * **OSS Dashboard \[AHU-VAV]** -- for setups with parent-child devices (for example, AHU-VAV). Includes an AHU Startup Details table on the Current Day page. * **OSS Dashboard \[FCU]** -- for individual devices (for example, FCU, AHU, or VAV alone). Replaces the AHU Startup Details table with a Weather Widget. Filter the dashboard by date, area, and schedule to focus on specific devices or time periods. ### Key metrics * **Comfort Index (CI)** -- the difference between the temperature setpoint and the actual zone temperature at occupancy start (when people arrive) * **Recovery Temperature (RT)** -- the difference between the temperature setpoint and the zone temperature at device OSS start (when OSS starts the device) * **Hours Saved** -- total runtime hours saved compared to the pre-OSS schedule (requires manual data submission) ### Current Day The Current Day page is updated every hour and provides an overview of devices configured with OSS for the current day. The top cards display key metrics at a glance. The FCU template replaces the AHU Startup Details table with a Weather Widget showing current conditions and a seven-day forecast. ![OSS Dashboard Current Day FCU template showing Balanced operation mode, 369 Total Fan Coil Units, 273 Devices Eligible and Configured For OSS, 102 Devices Reaching Setpoint Today, 27 min Time to Setpoint, weather widget for Chrysler House Detroit showing 38 degrees F, device breakdown with 34 Reached Setpoint OSS Controlled, 68 Already At Setpoint, 0 Reached After 4 hrs, 0 Unreached, 0 Failed, and start times from 03:10 to 06:31](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-fcu-cards.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5e8335069afdb7caa328ac25ea77136a) The FCU dashboard shows operation mode, total devices, devices eligible for OSS, devices reaching setpoint, time to setpoint, weather conditions, and start time statistics The **Hourly Out-of-Setpoint Deviation** heatmap shows how much devices within each schedule deviate from their setpoint throughout the day. Green indicates minimal deviation, while red and blue indicate significant deviation. Each cell displays the actual deviation value in degrees. ![Hourly Out-of-Setpoint Deviation heatmap showing four schedules with values from negative 1.3 degrees F to positive values across hourly intervals from 12 AM to 7 AM, with a color scale from blue at negative 5 to red at positive 5](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-heatmap-values.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b94a62823000fb3ec4a8e96be596b98b) The heatmap shows hourly setpoint deviation per schedule with degree values, ranging from blue (below setpoint) to green (on target) to red (above setpoint) The **Optimized Devices and Time to Setpoint** chart shows the number of devices optimized per floor and the average time to reach setpoint. The **Devices Satisfied Hourly** chart shows how many optimized devices reached setpoint at each hour. Use the `Scheduler` and `Device Filter` dropdowns to narrow down the view. ![Optimized Devices and Time to Setpoint bar chart showing device counts per floor with an Average Time to Setpoint trend line decreasing from 25 to 0 minutes, and Devices Satisfied Hourly heatmap showing satisfaction counts from 4 AM to 7 AM across floors](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-optimized-floor.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=38f553139845b114525abb6d4c01c43a) The bar chart shows optimized device counts per floor with a time to setpoint trend line, and the heatmap shows hourly satisfaction rates The **Device Time to Recovery** scatter plot shows individual device performance. Each point represents a device, and colors represent schedules. Devices in the upper-left corner (long recovery time, low recovery temperature) may need attention. Devices in the lower-right corner are recovering efficiently. ![Device Time to Recovery scatter plot showing device data points for Schedule, with Recovery Temperature on the x-axis from 0 to 10 degrees F and Time to Setpoint on the y-axis from 0 to 70 minutes](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-scatter-fcu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=3695d3e31faed908a58df696864d24ea) The scatter plot shows each device's recovery temperature versus time to setpoint, helping identify outliers The **Area, Schedule and Device Info** table provides a hierarchical view of metrics grouped by area, schedule, and device. You can see start times, recovery temperature, time to setpoint, and whether devices satisfied early or late. ![Area Schedule and Device Info table grouped by Floor 17, Floor 12, Floor 4, and Floor 8, showing individual devices with Start Time, Recovery Temperature, Time to Setpoint, Satisfied Early, and Satisfied Late columns with green color coding](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-area-table-fcu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=8db64263c9230cced88ce17fde6204d7) The hierarchical table shows device-level metrics grouped by floor and schedule, with green color-coded satisfaction timing The **Device Details** table at the bottom shows specific device information including start time, setpoint reached time, target time, zone temperature at OSS start, and heating and cooling setpoints. ![Device Details table showing devices with Device, Area, Scheduler Name, Start Time, Setpoint Reached, Target Time, Zone Temp at OSS Start, Heating Setpoint, and Cooling Setpoint columns, listing VAV and FPB devices across Basement and Floor areas](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-device-details-fcu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5b5553ea0b83db556884356066c12731) The device details table shows individual device data with start times, setpoint values, and zone temperatures at OSS start ### Historical The Historical page is updated every hour and provides long-term performance data over a selected time period. Use this page to track OSS performance trends and identify devices that consistently underperform. ![OSS Dashboard Historical page with Date Time Local, Area, and Schedule filters, cards showing Hours Saved 2161 hours, Comfort Index 0.3 degrees C, Config Devices 375, and Time to Setpoint 0 min, and a Startup Details table showing daily earliest and latest start times](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-historical.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=a783c168851ad79edbe9bfe4e2b2d916) The Historical page shows filters, hours saved, comfort index, and startup details over a configurable date range The Historical page includes the same chart types as Current Day but aggregated over the selected date range. The **Daily Hours Saved** chart shows hours saved by OSS per day. Below it, the **Number of Optimized Devices** chart shows how many devices OSS optimized per day with the average time to setpoint trend line. ![Daily Hours Saved bar chart showing approximately 180 hours saved per day from April 13 to April 28, with dips on weekends, and Number of Optimized Devices bar chart showing device counts with an Average Time to Setpoint trend line](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-daily-hours.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=0d8cecdb2d67f90fef93e25c9321f45d) Daily Hours Saved shows runtime savings per day, while Number of Optimized Devices tracks daily optimization counts The **Number of Devices That Did Not Reach Setpoint** chart shows daily failure counts. The **Satisfaction Time** chart tracks when devices reached setpoint relative to occupancy start, with Satisfied Early (yellow) and Satisfied Late (orange/red) indicators and a Recovery Temperature trend line (purple). ![Number of Devices That Did Not Reach Setpoint bar chart showing counts per day, and Satisfaction Time chart with Recovery Temperature trend line, Satisfied Early bars in yellow, and Satisfied Late bars in orange](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-historical-charts.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=e98324cbe7f1bcc6ca6b874959e31130) Devices that did not reach setpoint and satisfaction timing trends help identify performance issues over time The **Schedule and Device Info** table provides aggregated metrics grouped by schedule and device. Below it, the **Top 10 Devices That Took Longest to Reach Setpoint** table highlights devices that may need attention based on their average recovery time. ![Schedule and Device Info table grouped by schedule showing Recovery Temperature, Time to Setpoint, Satisfied Early, and Satisfied Late columns with green color coding, and Top 10 Devices That Took Longest to Reach Setpoint table showing device, area, schedule, time to setpoint, and recovery temperature](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-historical-tables.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5307da84b33c1039823523bc4d6c14ba) The schedule/device table and top 10 slowest devices table help identify underperforming equipment #### Hours Saved metric The Hours Saved metric is not calculated automatically. Submit a data sheet to KODE support at [support@kodelabs.com](mailto:support@kodelabs.com) with the following fields for each schedule: * **Building Name** -- the name of the building * **Schedule Name** -- the scheduler name in Cloud BMS * **Day of Week** -- the day of the week (Monday through Saturday) * **Space Entry Time** -- the expected occupant arrival time used to benchmark target comfort time * **Pre-OSS Start Time** -- the typical scheduled HVAC start time before OSS activation ### Config Changes The Config Changes page is updated daily. It tracks changes to configured devices that may have made them incompatible with OSS. The top cards show Compatible Devices, Active Configs, Inactive Configs, Expired Configs, and Adapters Affected. The **Detected Change Type** chart and **Expired Configs Per Adapter** chart help identify which changes are causing incompatibility. ![Config Changes page showing 419 Compatible Devices, 419 Active Configs, 0 Inactive Configs, 2 Expired Configs, 1 Adapter Affected, Detected Change Type pie chart showing Point Schedule Refs Change, Expired Configs Per Adapter bar chart, and Expired Config Details table showing FC\_4\_3 and FC\_4\_4 devices with Point Schedule Refs Change detected on April 14 2026](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-config-changes.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=8431dc57536a046768f3c8eb234a0256) The Config Changes page shows expired configs, change types, and affected adapters with device-level details A device may appear more than once if multiple changes were detected on the same day. Review the **Expired Config Details** table to identify which devices were made incompatible and take corrective action to restore compatibility. ### Troubleshooting The Troubleshooting page is updated every hour. It displays overrides made by OSS on configured devices. Filter by `Date Time Local`, `Override Status`, and `Canonical Type` to narrow down specific issues. The top cards show Devices Overridden and Issues counts. ![Troubleshooting page with Date Time Local set to Current Week, Override Status and Canonical Type filters, 2 Devices Overridden, 0 Issues, and Override Details table showing FC\_21\_12 and FC\_21\_11 devices with Occupancy Cmd point overridden to Occupied for 41 minutes on May 11 2026](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/oss/kode-os-oss-dashboard-troubleshooting.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b775f02e5a7d8855ae7d8fc246f2df58) The Troubleshooting page shows OSS override details with device name, point, requested and current values, duration, and any issues The **Override Details** table shows the timestamp, device name, point name, requested value, current value, duration, and any issues that occurred during the override. Use this page to understand why a device could not be turned on by OSS. ## Next steps > [card] [Schedules](/products/kode-os/schedules) > > Set up the schedules that OSS uses to determine target satisfaction times. > [card] [Devices](/products/kode-os/devices/devices) > > Manage the equipment that OSS optimizes. # Command and control points Source: https://docs.kodelabs.com/products/kode-os/points/commanding-points Send commands to writable points from device details, a floor plan, or a Building BI table. > [!NOTE] > > Command and control is a building-level feature. Select a building from the [sites list](/products/kode-os/sites-and-map) before you command points. Commanding and controlling equipment lets you adjust setpoints and variables to influence how equipment operates. You can only perform these actions on **writable points**. The command dialog is the same across integrations. BACnet devices, API thermostats, and other connectors all use this write-back flow. The underlying protocol depends on the data source, not on the dialog itself. ## Writable points Writable points accept commands from Cloud BMS. Read-only points report measurements and status but do not accept writes. See [Points](/products/kode-os/points/points#point-types) for the difference between read-only and writable point types. To enable or disable writability on a point, modify it from [device details](/products/kode-os/devices/devices) or use [points batch update](/products/kode-os/points/points-batch-update). ## Access command and control You can command a point from device details, a floor plan, or Building BI. Each path opens the same command dialog. ### From a floor plan Open an [area floor plan](/products/kode-os/areas) and click a smart marker. That click opens the command dialog for the device's writable points. You can also hover a device marker to expand its point values. Writable points display an edit icon next to the value. ![Expanded device marker for VAV\_210 showing Zone Temp Setpt and Zone Temp values with edit icons](https://mintcdn.com/kodelabs/euAGYgyin2AxlZ4b/images/kode-os/areas/kode-os-areas-device-hover.png?fit=max\&auto=format\&n=euAGYgyin2AxlZ4b\&q=85\&s=abf27db266f26f459dd549d66539c8e3) Writable points on a floor plan display an edit icon next to the point value Click the edit icon to open the command dialog, or click the device name to open device details. ### From Building BI In Building BI, click a point in a chart or table. That click opens the command dialog for the point. ### Navigate to device details Use any of these paths to open the device details page: * Open the building dashboard, select **`Devices`**, then select the device from the list * Search for a device using **universal search** ![Devices list with columns for name, type, area, location, and points, with filter options at the top](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-list.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=3e39d1f6875e34bd77d977ec2315c0ae) The Devices list shows all equipment in the building with filters and search On the device details page, hover over a point value. Writable points display a blue box indicating the point accepts commands. ## Send a command **1. Open the command dialog** From device details, click a writable point value. From a floor plan, click a smart marker, or click the edit icon next to a writable point. From Building BI, click the point in a chart or table. **2. Configure the command** Set the command parameters in the Action section. ![Command dialog for Discharge Air Temp showing Override action, value field, duration, reason, permanent checkbox, and current levels including priority 8 and fallback](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-command-dialog.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=614858cf3b4bc6e1aef9603ebb3812bf) The command dialog shows action, value, duration, and reason fields with current levels at the bottom **Command parameters** | Field | Description | | - | - | | `Priority` | The command action to apply (`Override`, `Set`, `Auto`, or `Release`). See the action mappings below. | | `Value` | The value to write (for example, `62.6 °F` for a temperature setpoint). Use the `+` and `-` buttons to adjust. | | `Duration` | How long the command remains active before auto-reverting (hours and minutes) | | `Reason` | A predefined reason from the dropdown | | `Permanent` | Check this to make the command persist without auto-reverting | | `Specific Reason` | A free-text note explaining why you made the change | The bottom of the dialog displays the current levels and their values. Click `Activity Log` in the upper-right corner to view the full command history for this point. **3. Submit the command** Click `Save Changes` to send the command to the device. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). > [!NOTE] > > Schedules, OSS, and FTT can also write to points at specific priority levels. When a schedule is actively commanding a point, the command dialog shows the schedule's priority level. See [schedule command levels](/products/kode-os/schedules#schedule-command-levels) for details. ## Command from other views The same command dialog is available when you click writable points on [system graphics](/products/kode-os/systems), [device graphics](/products/kode-os/graphics/device-graphics), and [area floor plans](/products/kode-os/areas). To write values to many points at once, use [mass write](/products/kode-os/mass-write) from the portfolio view. ## Next steps > [card] [Devices](/products/kode-os/devices/devices) > > View device details, trends, and point lists for individual equipment. > [card] [Areas](/products/kode-os/areas) > > Command writable points from interactive floor plans. > [card] [Mass write](/products/kode-os/mass-write) > > Write multiple points across buildings in a single tracked job. > [card] [Points batch update](/products/kode-os/points/points-batch-update) > > Enable or disable writability across many points at once. # Points Source: https://docs.kodelabs.com/products/kode-os/points/points Understand and manage the individual data values associated with your building equipment in Cloud BMS. > [!NOTE] > > Points is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its points. A point is the most granular unit of data in Cloud BMS. Each point represents a single data value associated with a device: a temperature sensor reading, a valve position, a setpoint, an occupancy status, or a fan speed command. Points are the foundation of monitoring, control, trending, and analytics in the platform. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR DEV[Device] -- "contains" --> RO[Read-Only Point] DEV -- "contains" --> WR[Writable Point] VDEV[Virtual Device] -- "contains" --> VP[Virtual Point] DEV -- "mirrors to" --> CP[Copied Point] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef rose stroke:#FF5978,fill:#FFDFE5,color:#8E2236 classDef peach stroke:#FBB35A,fill:#FFEFDB,color:#8F632D class DEV,VDEV sky class RO,WR rose class VP,CP peach ``` ## Point types Cloud BMS categorizes points into four types based on their origin and behavior: | Type | Description | | - | - | | **Read-only** | Data values that report a measurement or status. You can view and trend these points but cannot write to them. Examples: temperature sensors, humidity readings, power consumption. | | **Writable** | Points that accept commands to change equipment behavior. Examples: temperature setpoints, fan speed commands, lighting levels. | | **Virtual** | Calculated or manually defined points on virtual devices. These do not correspond to a physical sensor. Examples: aggregated totals, derived calculations. | | **Copied** | Mirrors of existing points duplicated into another device context. The source device retains ownership of the data. | ## How points are discovered When you add a data source, Cloud BMS discovers the available devices and their points through the discovery process. Discovery queries the external system and imports the raw point names, values, and metadata. After discovery, points appear with their native names from the data source (for example, `AHU1.SA-T` or `Zone3_OccSensor`). You then normalize these raw names using device templates and the ontology mapping tools. ## Navigate points From the building view, click **`Points`** in the left navigation. The Points section contains four sub-pages: **Points Status**, **Points List**, **Batch Update Points**, and **Mass Write Points**. ### Points Status **Points Status** gives you a real-time health summary of every point in the building. Status badges across the top show counts for **Ok**, **Down**, **Fault**, **Disabled**, **No Value**, **Overridden**, **FDD**, and **Stale** points. Click any badge to filter the table to that status. The table lists each point with its **Name**, **Value**, **Field**, and **Device**. Use the search bar to find a specific point by name. ![Points Status page with status badges showing Ok 1390, Down 0, Fault 0, Disabled 0, No Value 29, Overridden 3, FDD 0, and Stale 0, plus a table listing points with Name, Value, Field, and Device columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-status-page.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=9242cb221c18c6cf41cde0ade9b8aee2) Points Status shows live health badges and a sortable table of all building points ### Points List **Points List** provides the same point data with advanced filtering. Use the filter row at the top to narrow results by **Field**, **Kind**, **Device Type**, **Ontology Type**, **Area**, **Data Sources**, or **Writability**. You can also access **`Mass Write Points`** directly from this page. ![Points List page with filter dropdowns for Field, Kind, Device Type, Ontology Type, Area, Data Sources, and Writability across the top, Export and Mass Write Points buttons, and a table listing points with Name, Value, Field, and Device columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-list-page.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b5b3001fddc0def003114ded4ee2751c) Points List adds filtering controls for Field, Kind, Device Type, Ontology Type, Area, Data Sources, and Writability ### Export points Cloud BMS supports two export workflows for points. Use **Export** on **Points Status** or **Points List** to download the current point inventory. Use **Export Point Timeseries** to download historical values as CSV for analysis outside the platform. #### Export point list Both **Points Status** and **Points List** include an **`Export`** button. The export captures the filtered point list as it appears on screen, not historical readings. Click **`Export`** to open the dialog. Enter a **File Name**, choose which **Columns** to include, then click **`Export`** to download the file. ![Export dialog with File Name text field, Columns dropdown showing Selected 8, and Cancel and Export buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-export-dialog.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=4d887f35c324f92c3b0e611ecb57b445) The export dialog lets you name the file and choose which columns to include #### Export point timeseries **Export Point Timeseries** exports historical point data as CSV. Use it to share evidence with contractors, analyze data in Excel, or build reports outside Cloud BMS. Open the export from any of these locations: | Location | Scope | | - | - | | [Trends](/products/kode-os/trends) | Building-wide — query and export points across the site | | **Device Details** | Single device — open the three-dot menu and select **Export Points** | | **System Details** | System scope — exports points on devices in that system | **1. Select points** In **Export Points**, stay on **Select points to Export**. Use the search bar and filters to narrow the list by **Ontology Field**, **Device Type**, **Canonical Type**, **Device**, **Area**, **Ontology Type**, **Data Source**, **Writability**, or **Kind**. Select one or more points, then click **Next**. ![Export Point Timeseries step 1 showing a list of points with checkboxes, values, fields, and device assignments](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-export-select-points.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=23e49ce3b6e6286e470607a60de6123e) Step 1 filters and selects points for the timeseries export **2. Configure export settings** Choose **Export Format**, set the **Time range**, then configure format-specific options. Click **Export** to download the CSV. ![Export settings showing Raw List and Pivoted format options, time range selector, granularity dropdown, and columns picker](https://mintcdn.com/kodelabs/njejy12QoNdTJ3U4/images/kode-os/devices/kode-os-devices-export-settings.png?fit=max\&auto=format\&n=njejy12QoNdTJ3U4\&q=85\&s=67607aea8d1560b5c10c183e2d55eece) Step 2 sets format, time range, granularity, and columns ##### Export formats | Format | Structure | Best for | | - | - | - | | **Raw List** | One row per collected sample; points grouped and sorted by point | Troubleshooting, audit trails, exports that need metadata per record | | **Pivoted** | Time periods as rows; points as columns | Spreadsheet analysis, comparing multiple points on the same time axis | **Raw List** exports every collected value for the selected points. It does not support granularity or aggregation. You can choose which metadata columns to include, such as **Point Display Name**, **Original Name**, **Field**, **Device Name**, **Date & Time (US)**, **Value**, **Unit**, and **Status**. **Pivoted** aligns data to time buckets and is optimized for summarized reporting. Select **Granularity** and, when granularity is not **Raw**, set an aggregation function per point. ##### Granularity (Pivoted only) | Option | Description | | - | - | | **Raw** | No time alignment | | **1 min**, **2 mins**, **5 mins**, **15 mins**, **30 mins** | Sub-hourly buckets | | **1 hour**, **1 day** | Hourly or daily summaries | When you select a non-raw granularity, choose **Original Name** or **Display Name (Ontology)** for column headers. Review the **Aggregate Functions** section and set a function for each exported point. ##### Aggregation functions (Pivoted only) | Point type | Available functions | | - | - | | **Number** | Average, Sum, Median, Min, Max, First, Last, Count, Delta | | **Boolean / Enum** | First, Last, Longest value active | **Longest value active** returns the value that was active for the longest duration within the alignment period. For example, with **1 hour** granularity, the export uses the state that held for the most time during that hour. ##### Limits > [!WARNING] > > Each export supports up to **500** points and **800,000** total rows. Row count depends on time range, number of points, and collection frequency. If the export exceeds the limit, reduce the time range or export fewer points. ##### Fill behavior (Pivoted) When granularity is applied: * If a point is **down** for the entire alignment period, the export value is null or down for that period. * If a point has status **OK** but no new sample during the period, the export carries forward the **last value** — but only for gaps **under one hour**. * If a point has no value for **longer than one hour**, the export does not keep filling. Values are treated as missing or down based on status. ## Mass write points **Mass write points** sends write commands to multiple writable points in a single tracked job. Use it when you need the same priority, value, and duration applied across many setpoints or commands — for example seasonal setpoint changes, releasing overrides overnight, or peak demand reductions. This workflow writes live values to equipment. To change point metadata, writability, or normalization instead, use [Points batch update](/products/kode-os/points/points-batch-update). For portfolio-wide jobs across many buildings, see [Mass write](/products/kode-os/mass-write). ### Access mass write points > [tab] Building level > > 1. Select a building from the [sites list](/products/kode-os/sites-and-map). > 2. Open **`Points`** in the left navigation. > 3. Click **`Mass Write Points`** in the left sub-menu. > > You can also open **`Mass Write Points`** from **Points List**. > > The **Mass Write Points** page lists previous jobs for the building. Search by job name, review status and statistics, or click **`Write Points`** to start a new job. > > ![Mass Write Points page at building level with job list showing Name, Buildings, Statistics, User, Reason, and Time columns, search bar, and Write Points button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-jobs.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=ce69a233291f6220d338c1e4ffbcd3b6) > > The Mass Write Points page lists previous jobs and provides access to Write Points > [tab] Portfolio level > > 1. From the portfolio view, open **`Mass Write`**. > 2. Click **`Points`** in the left-side menu. > 3. Click **`Write Points`** to start a new job or open an existing job from the list. > > See [Mass write](/products/kode-os/mass-write) for the full portfolio workflow, permissions, and screenshots. ### Selection and search Only writable points appear in the mass write list. Points are not selected by default — select targets explicitly with row checkboxes. Use **`Select all`** to include every point across all pages. After **`Select all`**, deselect individual exceptions as needed. Use **Filters** to narrow the list by point type, canonical type, area, ontology field, data source type, and other attributes. To find non-templated points, set **Ontology Field** to **Not Assigned**. Search supports three match modes — **Starts with**, **Contains**, and **Exact** — across these fields: | Field | Description | | - | - | | **Point Name** | Display or raw point name | | **Path** | Point path in the data source | | **Ontology Field** | Normalized ontology field name | | **Device Name** | Device that owns the point | Toggle between **List** and **Grouped** view in the upper right. #### Grouped selection Grouped view simplifies selection for large point sets, especially non-templated points. In grouped mode: * Points are grouped by name and kind. * Each group shows the group name, point count, and device count. * Expand a group to review the underlying point list with the same columns as the standard table. * Select entire groups. You cannot include or exclude individual points inside a group. Filters still apply to the full list before grouping. Grouping does not replace filters. > [!WARNING] > > When writing very large point sets, confirm that target data sources can handle the write volume. This matters when many buildings share a single data source. ### Create a mass write points job **1. Open mass write points (building level)** From **Mass Write Points**, click **`Write Points`** to start a new job. **2. Filter buildings (portfolio only)** On portfolio-level jobs, use the **Filters** panel on the left to select buildings by country, state, city, or building name. Click **`Apply`** to load points from those buildings. **3. Filter and search points** Use **Filters** to narrow the list by **Kind**, **Area**, **Canonical**, **Field**, **Datasource**, and other attributes. Use the search bar to find points by name. Set **Ontology Field** to **Not Assigned** when you need non-templated points. **4. Select points** Choose targets in **List** or **Grouped** view. Use row checkboxes or group checkboxes, or click **`Select all`** in the selection banner to include every point across all pages. Deselect any exceptions. ![Select Points page at building level with Kind, Area, Canonical, Field, and Datasource filters, four points selected, Select all link, and point table with Name, Value, Point Type, Device, and Data Source Type columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-select-points.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=fc699aa12b1319cfbf1295e1cedff669) The Select Points step shows filters, List and Grouped view toggle, and a selection count banner Click **`Continue to Set Values`** when the selection is final. > [!WARNING] > > You cannot remove points in later steps. Verify your selection before continuing. **5. Set values and execute** Enter a **Name**, **Reason Type**, and **Reason Description**. Points are grouped automatically by ontology field, unit, and accepted values. Configure each group: | Field | Description | | - | - | | **Priority** | Write priority: **Override**, **Auto**, **Set**, or **Release** | | **Value** | Value to write to every point in the group. Negative values are supported for numeric points. | | **Duration** | How long the value persists before reverting. Check **Permanent** to keep the value until released. | Click **`Save`** for each group. Color highlights indicate missing information. ![Set Values page at building level with Name, Reason Type, and Reason Description fields and a point group table showing Override priority, true value, and 00:30 duration](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-set-values.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b765a98efce9e64d93da5c31d9ac2cbb) Set Name, Reason Type, and priority, value, and duration for each point group After saving all groups, click **`Execute`** to start the write operation. ### Job details and post-actions After execution, Cloud BMS opens the job details page with status, timestamp, reason, user, and success and failure counts per group. Click the blue point counts to view individual points and their write results. ![Mass Write Points job details page at building level showing Completed status, time, reason, user, and Point Groups table with Priority, Value, Duration, and Status columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-job-details.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=56dc16e22f0353803959481115d0f143) Job details shows status, reason, user, and per-group write results From job details, use the three-dot menu to: | Action | Behavior | | - | - | | **Edit Details** | Update the job name or description | | **Re-run Job** | Re-execute using all original points. You can edit the selection and write configuration before running | | **Retry Job with failed points** | Re-execute immediately for failed points only. You can edit the configuration before running | ![Job details three-dot menu showing Edit Details, Re-run Job, and Retry Job with failed points options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-job-actions.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=40e3f7fc03d5bee5d8e9341d51d5b8cb) The job actions menu provides options to edit, re-run, or retry failed points Click **`Export`** to download job results as CSV. Enter a **File Name**, choose which **Columns** to include, then click **`Export`**. The CSV export includes **Building ID**, **Building Name**, **Device ID**, **Device Name**, **Name**, **Field**, **Priority**, **Value**, **Duration**, **Status**, and **Failed Reason**. ![Export dialog with File Name field and Columns dropdown set to All Columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-export-dialog.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=bfd48f60254944eae36546b979f6aa8d) Export job results with a custom file name and column selection Completed jobs remain listed on the **Mass Write Points** page. Open the three-dot menu on any job row to edit details, re-run, or retry failed points. ![Mass Write Points job list with three-dot menu open showing Edit Details, Re-run Job, and Retry Job with failed points options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-mass-write-jobs-actions.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=ca888b2843883304a225f61f41a00269) Manage previous jobs from the Mass Write Points list ## Normalize point names Point normalization standardizes raw point names from different manufacturers into a consistent ontology format. This is critical for cross-building analytics, automated fault detection, and dashboard generation. Cloud BMS provides an ML-powered auto-suggest tool that recommends standardized names based on the raw point name. The mapping follows the ontology field format: `[aggregator]_[descriptor]_[component]_[measurement descriptor]_[measurement]_[point type]` For example: | Raw Point Name | Standardized Name | | - | - | | `SA-T` | `supply_air_temperature_sensor` | | `RA-T` | `return_air_temperature_sensor` | | `CLG-SP` | `cooling_temperature_setpoint` | | `FAN-CMD` | `fan_run_command` | | `OCC-STS` | `occupancy_status` | > [!TIP] > > Consistent normalization enables platform-wide benefits: simplified dashboard generation (filter and select points by ontology field), cross-building comparisons, and automated fault detection rules that apply universally. ## Point writability Writable points allow you to command equipment directly from Cloud BMS. See [command and control points](/products/kode-os/points/commanding-points) for how to send commands from device details or a floor plan. To make a point writable (or remove writability), you can modify it individually from the device details or in bulk using the points batch update feature. ### Remove writability from a single point **1. Navigate to the device** Go to `Devices` and select the device containing the point. **2. Open point editing** From device details, click the information icon in the right sidebar, then click the edit button to open the full point list. **3. Modify writability** Click the point you want to update. In the panel that opens, uncheck the `Writable` option and remove the `Writable` tag. Click `Save`. ## Enum mapping Some points report enumerated values (enums) rather than numeric readings. For example, an operating mode point might report values like `0`, `1`, `2` that correspond to `Off`, `Heat`, `Cool`. Enum mapping translates these numeric codes into human-readable labels. Navigate to the enum mapping interface from the device or point settings to configure these translations. > [!NOTE] > > Enum mappings are critical for features like OSS, FDD, and FTT. For example, OSS requires a correctly mapped `Occupied Mode` enum to determine when a space is in occupied or unoccupied mode. Incorrect mappings can cause false fault detections or missed schedule optimizations. ## Next steps > [card] [Trends](/products/kode-os/trends) > > Plot point history and export timeseries from the building-wide Trends module. > [card] [Command points](/products/kode-os/points/commanding-points) > > Send commands to writable points from device details or floor plans. > [card] [Copied points](/products/kode-os/devices/copied-points) > > Mirror point values into other devices for shared monitoring. > [card] [Points batch update](/products/kode-os/points/points-batch-update) > > Make mass edits to point metadata, writability, and normalization. # Points batch update Source: https://docs.kodelabs.com/products/kode-os/points/points-batch-update Make mass edits to point metadata, writability, normalization, and units across multiple points at once. Points batch update allows you to modify properties across multiple points simultaneously. Use it when you need to change writability settings, rename or reclassify points, assign units of measurement, or apply normalization tags at scale. ## When to use batch update Batch update is most effective when you need to: * Enable or disable writability across a group of points * Apply normalization tags to multiple unnormalized points * Assign or update units of measurement * Reclassify points after a device template change ## Perform a points batch update **1. Open Batch Update Points** From the building view, click **`Points`** in the left navigation bar, then select **`Batch Update Points`** from the sidebar. **2. Select points** Use the filter row at the top to narrow results by **Field**, **Kind**, **Device Type**, **Ontology Type**, **Area**, **Data Sources**, or **Writability**. Select the points you want to update by checking the boxes next to each point name. The selection count appears above the table. **3. Set properties** The **Properties** panel on the right side displays the fields you can modify for the selected points. **Available properties** | Property | Description | | - | - | | `Display Name` | Set a human-readable display name for the selected points | | `Unit` | Set or update the unit of measurement (°F, °C, CFM, PSI) | | `Add tags` | Apply tags to the selected points | | `Remove Tags` | Remove existing tags from the selected points | | `Min Value` / `Max Value` | Define the expected value range | | `COV Tolerance` | Set the change-of-value tolerance threshold | | `Precision` | Choose the decimal precision for displayed values | | `Metadata` | Add or update metadata key-value pairs | | `Writability` | Toggle writability on or off for the selected points. When enabled, choose which actions the points accept: `Override`, `Set`, and optionally `Set in Slot16` (Niagara). `Set in Slot16` makes `Set` write to priority 16 instead of the fallback or default value. | | `Graph Visibility` | Toggle whether the points appear on graphs by default | ![Batch Update Points page with filter row for Field, Kind, Device Type, Ontology Type, Area, Data Sources, and Writability, two points selected in the table, and Properties panel on the right showing Display Name, Unit, Add tags, Remove Tags, Min and Max Value, COV Tolerance, Precision, Metadata, Writability, and Graph Visibility fields](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-batch-update-page.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=a01926218e11332d8cb10196fb2b4c3f) Select points from the table and edit their properties in the right panel **4. Apply and review changes** Click **`Apply`** at the bottom right. The **Review Changes** dialog shows a summary of the changes that will be applied to the selected points. ![Review Changes dialog showing the changes to be applied, with Unit set to amperes - A, a Show selected points checkbox with count of 2, and Cancel and Confirm buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-batch-update-review-changes.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=3ad9d9a9631fb74eb1dcbf7ce1e81ccf) Review Changes summarizes the updates before you confirm Check **`Show selected points`** to expand the list and verify which points will be affected. Click **`Confirm`** to apply the update. ![Review Changes dialog with Show selected points checked, displaying a table with NAME, FIELD, and VALUE columns listing SA\_T and Occ\_Mode, plus Cancel and Confirm buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/points/kode-os-points-batch-update-review-expanded.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=1967b3f8d99fe3cde30f6bb3916926e0) Expand Show selected points to verify the exact points that will be updated > [!WARNING] > > Changing writability affects whether users can command these points from Cloud BMS. Removing writability from points that are actively used in schedules or automation may disrupt those operations. ## Next steps > [card] [Points](/products/kode-os/points/points) > > Return to the points overview for normalization and management. > [card] [Device templates](/products/kode-os/devices/device-templates) > > Use templates to automate point normalization at the device level. # Ontology field catalog Source: https://docs.kodelabs.com/products/kode-os/reference/ontology Search canonical types and ontology point fields used to model equipment in Cloud BMS. The KODE ontology follows the Google Digital Buildings ontology (Google DBO). Canonical types classify equipment. Ontology point fields classify the points on that equipment. Use this page to look up a canonical type, a field group, or a point field. The live modeling workflow is on [device templates](/products/kode-os/devices/device-templates). ## How a field name is built A field name joins parts in a fixed order. Each part is used at most once, except descriptors, which can repeat. `[aggregator]_[descriptor]_[component]_[measurement descriptor]_[measurement]_[point type]` A raw point such as `SA-T` can map to `supply_air_temperature_sensor`. Some display names include a suffix token. Cloud BMS fills that token when the template is applied. ## Field catalog The catalog lists 50 canonical types and 2783 point fields. Choose a type or search for a field. Each table lists the field, the display name, and any required values. Search fields Canonical type Canonical type filters ```json theme={"theme":{"light":"github-light","dark":"github-dark"}} [ {"type": "ahu", "group": "Air Humidity", "field": "cooling_coil_air_humidity_sensor", "display": "Cool Coil Air Humid", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "discharge_air_humidity_sensor", "display": "Discharge Air Humid", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "discharge_air_humidity_setpoint", "display": "Discharge Air Humid Setpt", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "heating_coil_air_humidity_sensor", "display": "Heat Coil Air Humid", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "return_air_dehumidification_setpoint", "display": "Return Air DeHumid Setpt", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "return_air_humidity_sensor", "display": "Return Air Humid", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "return_air_humidity_setpoint", "display": "Return Air Humid Setpt", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Air Humidity", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "cooling_coil_leaving_air_temperature_sensor", "display": "Cool Coil Leaving Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "cooling_coil_leaving_air_temperature_setpoint", "display": "Cool Coil Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "discharge_air_temperature_dewpoint_sensor", "display": "Discharge Air Dewpoint", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "discharge_air_temperature_sensor", "display": "Discharge Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "discharge_air_temperature_setpoint", "display": "Discharge Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "exhaust_air_temperature_sensor", "display": "Exhaust Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "heating_coil_leaving_air_temperature_sensor", "display": "Heat Coil Leaving Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "heating_coil_leaving_air_temperature_setpoint", "display": "Heat Coil Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "high_limit_discharge_air_temperature_setpoint", "display": "Max Discharge Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "low_limit_discharge_air_temperature_setpoint", "display": "Min Discharge Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "low_limit_mixed_air_temperature_setpoint", "display": "Min Mixed Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "mixed_air_temperature_sensor", "display": "Mixed Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "mixed_air_temperature_setpoint", "display": "Mixed Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "return_air_temperature_sensor", "display": "Return Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "return_air_temperature_setpoint", "display": "Return Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "supply_air_temperature_sensor", "display": "Supply Air Temp", "enums": ""}, {"type": "ahu", "group": "Air Temperatures Control", "field": "supply_air_temperature_setpoint", "display": "Supply Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "cold_deck_air_flowrate_sensor", "display": "Cold Deck Air Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "cold_deck_air_flowrate_setpoint", "display": "Cold Deck Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "cold_deck_air_pressure_sensor", "display": "Cold Deck Air Press", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "discharge_air_flowrate_sensor", "display": "Discharge Air Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "discharge_air_flowrate_setpoint", "display": "Discharge Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "effective_discharge_air_flowrate_setpoint", "display": "Eff Discharge Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "hot_deck_air_flowrate_sensor", "display": "Hot Deck Air Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "hot_deck_air_flowrate_setpoint", "display": "Hot Deck Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "hot_deck_air_pressure_sensor", "display": "Hot Deck Air Press", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_discharge_air_flowrate_setpoint", "display": "Max Discharge Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_occupied_cold_air_flowrate_setpoint", "display": "Max Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Max Occ Cooling Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_occupied_heating_discharge_air_flowrate_setpoint", "display": "Max Occ Heating Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_occupied_hot_air_flowrate_setpoint", "display": "Max Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_unoccupied_cold_air_flowrate_setpoint", "display": "Max UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Max UnOcc Cooling Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Max UnOcc Heating Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "max_unoccupied_hot_air_flowrate_setpoint", "display": "Max UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_discharge_air_flowrate_setpoint", "display": "Min Discharge Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_occupied_cold_air_flowrate_setpoint", "display": "Min Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Min Occ Cooling Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_occupied_heating_discharge_air_flowrate_setpoint", "display": "Min Occ Heating Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_occupied_hot_air_flowrate_setpoint", "display": "Min Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_unoccupied_cold_air_flowrate_setpoint", "display": "Min UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Min UnOcc Cooling Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Min UnOcc Heating Flow", "enums": ""}, {"type": "ahu", "group": "Airflows Control", "field": "min_unoccupied_hot_air_flowrate_setpoint", "display": "Min UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Exhaust Airflow Control", "field": "exhaust_air_flowrate_sensor", "display": "Exhaust Air Flow {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Exhaust Airflow Control", "field": "exhaust_air_flowrate_setpoint", "display": "Exhaust Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Exhaust Airflow Control", "field": "max_exhaust_air_flowrate_setpoint", "display": "Max Exhaust Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Exhaust Airflow Control", "field": "min_exhaust_air_flowrate_setpoint", "display": "Min Exhaust Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Outside Airflow Control", "field": "max_outside_air_flowrate_setpoint", "display": "Max Outside Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Outside Airflow Control", "field": "min_outside_air_flowrate_setpoint", "display": "Min Outside Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Outside Airflow Control", "field": "outside_air_flowrate_sensor", "display": "Outside Air Flow {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Outside Airflow Control", "field": "outside_air_flowrate_setpoint", "display": "Outside Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Return Airflow Control", "field": "return_air_flowrate_sensor", "display": "Return Air Flow {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Airflows Control - Return Airflow Control", "field": "return_air_flowrate_setpoint", "display": "Return Air Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "ahu", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "ahu", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "ahu", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "ahu", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "ahu", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ahu", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ahu", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ahu", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_differential_pressure_sensor", "display": "Diff Chilled Water Press", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_differential_pressure_setpoint", "display": "Diff Chilled Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_differential_temperature_sensor", "display": "Diff Chilled Water Temp", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_entering_temperature_sensor", "display": "Entering Chilled Water Temp", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_flowrate_sensor", "display": "Chilled Water Flow", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_flowrate_setpoint", "display": "Chilled Water Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_isolation_valve_run_command", "display": "Chilled Water Iso Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_isolation_valve_run_status", "display": "Chilled Water Iso Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_leaving_temperature_sensor", "display": "Leaving Chilled Water Temp", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_leaving_temperature_setpoint", "display": "Leaving Chilled Water Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_pressure_sensor", "display": "Chilled Water Press", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_pressure_setpoint", "display": "Chilled Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_valve_command", "display": "Chilled Water Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_valve_percentage_command", "display": "Chilled Water Valve Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_valve_percentage_sensor", "display": "Chilled Water Valve Percent", "enums": ""}, {"type": "ahu", "group": "Chilled Water", "field": "chilled_water_valve_status", "display": "Chilled Water Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_enable_command", "display": "Chilled Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_percentage_command", "display": "Chilled Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_command", "display": "Chilled Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_current_sensor", "display": "Chilled Water Pump {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_status", "display": "Chilled Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_differential_pressure_sensor", "display": "Diff Cond Water Press", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_differential_pressure_setpoint", "display": "Diff Cond Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_differential_temperature_sensor", "display": "Diff Cond Water Temp", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_entering_temperature_sensor", "display": "Entering Cond Water Temp", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_flowrate_sensor", "display": "Cond Water Flow", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_flowrate_setpoint", "display": "Cond Water Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_command", "display": "Cond Water Iso Valve Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_status", "display": "Cond Water Iso Valve Status", "enums": "On, Off"}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_sensor", "display": "Leaving Cond Water Temp", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_setpoint", "display": "Leaving Cond Water Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_pressure_sensor", "display": "Cond Water Press", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_pressure_setpoint", "display": "Cond Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_valve_command", "display": "Cond Water Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_valve_percentage_command", "display": "Cond Water Valve Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_valve_percentage_sensor", "display": "Cond Water Valve Percent", "enums": ""}, {"type": "ahu", "group": "Condenser Water", "field": "condensing_water_valve_status", "display": "Cond Water Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_enable_command", "display": "Cond Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_percentage_command", "display": "Cond Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_command", "display": "Cond Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_current_sensor", "display": "Cond Water Pump {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_status", "display": "Cond Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_count", "display": "Press Req", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_idle_count", "display": "Air Ignored Requests", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_multiplier_count", "display": "Press Req Multiplier", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_count", "display": "Cooling Req", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_idle_count", "display": "Cooling Ignored Requests", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_multiplier_count", "display": "Cooling Req Multiplier", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_count", "display": "Heating Req", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_idle_count", "display": "Heating Ignored Requests", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_multiplier_count", "display": "Heating Req Multiplier", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "high_limit_cooling_air_temperature_setpoint", "display": "Max Cooling Upd Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "high_limit_heating_air_temperature_setpoint", "display": "Max Heating Upd Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "low_limit_cooling_air_temperature_setpoint", "display": "Min Cooling Upd Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "low_limit_heating_air_temperature_setpoint", "display": "Min Heating Upd Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "max_cooling_request_air_temperature_setpoint", "display": "Max Cooling Req Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "max_heating_request_air_temperature_setpoint", "display": "Max Heating Req Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "max_request_damper_percentage_command", "display": "Max Press Req Damper Cmd", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "min_cooling_request_air_temperature_setpoint", "display": "Min Cooling Req Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "min_heating_request_air_temperature_setpoint", "display": "Min Heating Req Setpt", "enums": ""}, {"type": "ahu", "group": "Cooling, Heating, Pressure Requests", "field": "min_request_damper_percentage_command", "display": "Min Press Req Damper Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "balancing_damper_percentage_command", "display": "Balancing Damper Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "bypass_damper_percentage_command", "display": "Bypass Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "bypass_damper_percentage_sensor", "display": "Bypass Damper Sensor", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "cold_deck_damper_percentage_command", "display": "Cold Deck Damper Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "cold_deck_damper_percentage_sensor", "display": "Cold Deck Damper Status", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_closed_command", "display": "Damper Closed Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_command", "display": "Discharge Damper Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_open_command", "display": "Damper Open Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_percentage_command", "display": "Discharge Damper Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_percentage_sensor", "display": "Discharge Damper Percent", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "discharge_damper_status", "display": "Discharge Damper Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers", "field": "floor_damper_command", "display": "Floor Damper Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers", "field": "floor_damper_status", "display": "Floor Damper Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers", "field": "hot_deck_damper_percentage_command", "display": "Hot Deck Damper Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers", "field": "hot_deck_damper_percentage_sensor", "display": "Hot Deck Damper Percent", "enums": ""}, {"type": "ahu", "group": "Dampers - Exhaust Damper", "field": "exhaust_damper_command", "display": "Exhaust Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers - Exhaust Damper", "field": "exhaust_damper_percentage_command", "display": "Exhaust Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Exhaust Damper", "field": "exhaust_damper_percentage_sensor", "display": "Exhaust Damper {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Dampers - Exhaust Damper", "field": "exhaust_damper_status", "display": "Exhaust Damper {{suffix}} Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers - Mixed Damper", "field": "mixed_damper_command", "display": "Mixed Damper {{suffix}} Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Mixed Damper", "field": "mixed_damper_percentage_command", "display": "Mixed Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Mixed Damper", "field": "mixed_damper_percentage_sensor", "display": "Mixed Damper {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Dampers - Mixed Damper", "field": "mixed_damper_status", "display": "Mixed Damper {{suffix}} Status", "enums": ""}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "high_limit_outside_damper_percentage_command", "display": "Max Outside Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "low_limit_outside_damper_percentage_command", "display": "Min Outside Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "outside_damper_command", "display": "Outside Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "outside_damper_percentage_command", "display": "Outside Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "outside_damper_percentage_sensor", "display": "Outside Damper {{suffix}} Status", "enums": ""}, {"type": "ahu", "group": "Dampers - Outside Damper", "field": "outside_damper_status", "display": "Outside Damper {{suffix}} Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers - Return Damper", "field": "return_damper_command", "display": "Return Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Dampers - Return Damper", "field": "return_damper_percentage_command", "display": "Return Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dampers - Return Damper", "field": "return_damper_percentage_sensor", "display": "Return Damper {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Dampers - Return Damper", "field": "return_damper_status", "display": "Return Damper {{suffix}} Status", "enums": ""}, {"type": "ahu", "group": "Defrost Control", "field": "defrost_mode", "display": "Defrost Mode", "enums": "On, Off"}, {"type": "ahu", "group": "Defrost Control", "field": "defrost_status", "display": "Defrost Status", "enums": "On, Off"}, {"type": "ahu", "group": "Dehumidifier Control", "field": "dehumidifier_enable_command", "display": "DeHumid Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Dehumidifier Control", "field": "dehumidifier_run_command", "display": "DeHumid Cmd", "enums": ""}, {"type": "ahu", "group": "Dehumidifier Control", "field": "dehumidifier_run_percentage_command", "display": "DeHumid Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Dehumidifier Control", "field": "dehumidifier_run_status", "display": "DeHumid Status", "enums": "On, Off"}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "cold_deck_discharge_air_pressure_sensor", "display": "Cold Deck Discharge Air Press", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "cold_deck_discharge_air_pressure_setpoint", "display": "Cold Deck Discharge Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "cold_deck_discharge_air_temperature_sensor", "display": "Cold Deck Discharge Air Temp", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "cold_deck_discharge_air_temperature_setpoint", "display": "Cold Deck Discharge Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "cold_deck_zone_inlet_discharge_air_temperature_sensor", "display": "Cold Deck Floor Supply Temp", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "hot_deck_discharge_air_pressure_sensor", "display": "Hot Deck Discharge Air Press", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "hot_deck_discharge_air_pressure_setpoint", "display": "Hot Deck Discharge Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "hot_deck_discharge_air_temperature_sensor", "display": "Hot Deck Discharge Air Temp", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "hot_deck_discharge_air_temperature_setpoint", "display": "Hot Deck Discharge Air Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Dual Duct Air Handler", "field": "hot_deck_zone_inlet_discharge_air_temperature_sensor", "display": "Hot Deck Floor Supply Temp", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "discharge_air_pressure_sensor", "display": "Discharge Air Press", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "discharge_air_pressure_setpoint", "display": "Discharge Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "exhaust_air_pressure_sensor", "display": "Exhaust Air Press", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "exhaust_air_pressure_setpoint", "display": "Exhaust Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "high_limit_discharge_air_pressure_setpoint", "display": "Max Discharge Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "high_limit_mixed_air_pressure_setpoint", "display": "Max Mixed Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "low_limit_discharge_air_pressure_setpoint", "display": "Min Discharge Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "mixed_air_pressure_sensor", "display": "Mixed Air Press", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "mixed_air_pressure_setpoint", "display": "Mixed Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "return_air_pressure_sensor", "display": "Return Air Press", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "return_air_pressure_setpoint", "display": "Return Air Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "zone_inlet_discharge_air_pressure_sensor", "display": "Floor Supply Press", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls", "field": "zone_inlet_discharge_air_pressure_setpoint", "display": "Floor Supply Press Setpt", "enums": ""}, {"type": "ahu", "group": "Duct Air Pressure Controls - Filter Monitoring", "field": "filter_differential_air_pressure_sensor", "display": "Filter Diff Press", "enums": ""}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_mode", "display": "Econo Mode", "enums": "On, Off"}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_output_percentage_sensor", "display": "Econo Output", "enums": ""}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_season_mode", "display": "Econo Season", "enums": ""}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_specificenthalpy_setpoint", "display": "Econo Enthalpy Setpt", "enums": ""}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_status", "display": "Econo Status", "enums": "On, Off"}, {"type": "ahu", "group": "Economizer Control", "field": "economizer_temperature_setpoint", "display": "Econo Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Economizer Control", "field": "low_limit_economizer_output_percentage_command", "display": "Min Econo Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "ahu", "group": "Electric Heat Controls - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Electric Heat Controls - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Electric Heat Controls - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "ahu", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "ahu", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_angularvelocity_sensor", "display": "Discharge Fan RPM", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_command", "display": "Discharge Fan Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_current_sensor", "display": "Discharge Fan Current", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_enable_command", "display": "Discharge Fan Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_enable_status", "display": "Discharge Fan Enabled", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_energy_accumulator", "display": "Discharge Fan Total Energy", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_frequency_sensor", "display": "Discharge Fan Freq", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_mode", "display": "Discharge Fan Mode", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_power_sensor", "display": "Discharge Fan Power", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_run_time_accumulator", "display": "Discharge Fan Total Runtime", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_speed_percentage_command", "display": "Discharge Fan Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_speed_percentage_sensor", "display": "Discharge Fan Percent", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "discharge_fan_status", "display": "Discharge Fan Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "high_discharge_fan_speed_command", "display": "High Discharge Fan Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "high_discharge_fan_speed_status", "display": "High Discharge Fan Status", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "low_discharge_fan_speed_command", "display": "Low Discharge Fan Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "low_discharge_fan_speed_status", "display": "Low Discharge Fan Status", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "low_limit_discharge_fan_speed_percentage_command", "display": "Min Discharge Fan Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group", "field": "medium_discharge_fan_speed_command", "display": "Med Discharge Fan Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group", "field": "medium_discharge_fan_speed_status", "display": "Med Discharge Fan Status", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_command", "display": "Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_current_sensor", "display": "Exhaust Fan {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_run_time_accumulator", "display": "Exhaust Fan {{suffix}} Total Runtime", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_speed_percentage_command", "display": "Exhaust Fan {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_speed_percentage_sensor", "display": "Exhaust Fan {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "exhaust_fan_status", "display": "Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "high_exhaust_fan_speed_command", "display": "High Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "high_exhaust_fan_speed_status", "display": "High Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "low_exhaust_fan_speed_command", "display": "Low Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "low_exhaust_fan_speed_status", "display": "Low Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "low_limit_exhaust_fan_speed_percentage_command", "display": "Min Exhaust Fan Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "medium_exhaust_fan_speed_command", "display": "Med Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Exhaust Fan", "field": "medium_exhaust_fan_speed_status", "display": "Med Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "low_limit_return_fan_speed_percentage_command", "display": "Min Return Fan Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_angularvelocity_sensor", "display": "Return Fan {{suffix}} RPM", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_command", "display": "Return Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_current_sensor", "display": "Return Fan {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_frequency_sensor", "display": "Return Fan {{suffix}} Freq", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_run_time_accumulator", "display": "Return Fan {{suffix}} Total Runtime", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_speed_percentage_command", "display": "Return Fan {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_speed_percentage_sensor", "display": "Return Fan {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Fans Group - Return Fan", "field": "return_fan_status", "display": "Return Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "low_limit_supply_fan_speed_percentage_command", "display": "Min Supply Fan Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_angularvelocity_sensor", "display": "Supply Fan {{suffix}} RPM", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_command", "display": "Supply Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_current_sensor", "display": "Supply Fan {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_frequency_sensor", "display": "Supply Fan {{suffix}} Freq", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_run_time_accumulator", "display": "Supply Fan {{suffix}} Total Runtime", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_speed_percentage_command", "display": "Supply Fan {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_speed_percentage_sensor", "display": "Supply Fan {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Fans Group - Supply Fan", "field": "supply_fan_status", "display": "Supply Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Gas Heat Controls - Gas Valve Percentage Control", "field": "gas_heater_percentage_command", "display": "Gas Valve {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Gas Heat Controls - Gas Valve Percentage Monitoring", "field": "gas_heater_percentage_sensor", "display": "Gas Valve {{suffix}} Percent", "enums": ""}, {"type": "ahu", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_command", "display": "Gas Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_enable_command", "display": "Gas Heat Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Gas Heat Controls - Staged Gas Heating Monitoring", "field": "gas_heater_stage_status", "display": "Gas Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump", "field": "controller_cooling_output_percentage_label", "display": "Cool PID", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "controller_heating_output_percentage_label", "display": "Heat PID", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Pump", "field": "reversing_heating_cooling_valve_command", "display": "Rev Valve Cmd", "enums": "Cooling, Heating"}, {"type": "ahu", "group": "Heat Pump", "field": "reversing_heating_cooling_valve_status", "display": "Rev Valve", "enums": "Cooling, Heating"}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_angularvelocity_sensor", "display": "Variable Comp {{suffix}} RPM {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_frequency_sensor", "display": "Variable Comp {{suffix}} Freq {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_run_command", "display": "Variable Comp {{suffix}} Cmd {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_run_status", "display": "Variable Comp {{suffix}} Status {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_command", "display": "Variable Comp {{suffix}} Percent Cmd {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_sensor", "display": "Variable Comp {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_discharge_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Discharge Press", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_discharge_line_temperature_sensor", "display": "Comp {{suffix}} Discharge Temp", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_enable_command", "display": "Comp {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_enable_status", "display": "Comp {{suffix}} Enabled", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_run_time_accumulator", "display": "Comp {{suffix}} Total Runtime", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_start_counter", "display": "Comp {{suffix}} Start Total", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_suction_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Suction Press", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_suction_line_temperature_sensor", "display": "Comp {{suffix}} Suction Temp", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop", "field": "suction_line_temperature_sensor", "display": "Suction Temp {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_command", "display": "Comp {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_current_sensor", "display": "Comp {{prefix}} Stage {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_status", "display": "Comp {{prefix}} Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_command", "display": "Cool Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_current_sensor", "display": "Cool Stage {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_status", "display": "Cool Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_command", "display": "Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_current_sensor", "display": "Heat Stage {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_status", "display": "Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_air_entering_temperature_sensor", "display": "Heat Wheel Entering Temp", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_angularvelocity_sensor", "display": "Heat Wheel RPM", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_command", "display": "Heat Wheel Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_leaving_air_temperature_sensor", "display": "Heat Wheel Leaving Temp", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_leaving_air_temperature_setpoint", "display": "Heat Wheel Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_percentage_command", "display": "Heat Wheel Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_percentage_sensor", "display": "Heat Wheel Percent", "enums": ""}, {"type": "ahu", "group": "Heat Wheel", "field": "heat_wheel_status", "display": "Heat Wheel Status", "enums": "On, Off"}, {"type": "ahu", "group": "Heat Wheel", "field": "low_limit_heat_wheel_leaving_air_temperature_setpoint", "display": "Min Heat Wheel Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "high_limit_hot_water_leaving_temperature_setpoint", "display": "Max Hot Water Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_differential_pressure_sensor", "display": "Diff Hot Water Press", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_entering_temperature_sensor", "display": "Entering Hot Water Temp", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_flowrate_sensor", "display": "Hot Water Flow", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_flowrate_setpoint", "display": "Hot Water Flow Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_isolation_valve_run_command", "display": "Hot Water Iso Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_isolation_valve_run_status", "display": "Hot Water Iso Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_leaving_temperature_sensor", "display": "Leaving Hot Water Temp", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_leaving_temperature_setpoint", "display": "Leaving Hot Water Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_pressure_differential_setpoint", "display": "Diff Hot Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_pressure_sensor", "display": "Hot Water Press", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_pressure_setpoint", "display": "Hot Water Press Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_closed_command", "display": "Valve Closed Cmd", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_command", "display": "Hot Water Valve Cmd", "enums": "Open, Close"}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_open_command", "display": "Valve Open Cmd", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_percentage_command", "display": "Hot Water Valve Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_percentage_sensor", "display": "Hot Water Valve Percent", "enums": ""}, {"type": "ahu", "group": "Hot Water", "field": "hot_water_valve_status", "display": "Hot Water Valve Status", "enums": "Open, Close"}, {"type": "ahu", "group": "Hot Water", "field": "low_limit_hot_water_leaving_temperature_setpoint", "display": "Min Hot Water Leaving Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_enable_command", "display": "Hot Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_percentage_command", "display": "Hot Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_command", "display": "Hot Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_current_sensor", "display": "Hot Water Pump {{suffix}} Current", "enums": ""}, {"type": "ahu", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_status", "display": "Hot Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_enable_command", "display": "Humid Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_enable_percentage_command", "display": "Humid Enable Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_outside_air_temperature_enable_setpoint", "display": "Outside Temp Humid Setpt", "enums": ""}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_run_command", "display": "Humid Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_run_percentage_command", "display": "Humid Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_run_percentage_sensor", "display": "Humid Output", "enums": ""}, {"type": "ahu", "group": "Humidifier Control", "field": "humidifier_run_status", "display": "Humid Status", "enums": "On, Off"}, {"type": "ahu", "group": "HVAC Device Control", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "ahu", "group": "HVAC Device Control", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "ahu", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "ahu", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "ahu", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "ahu", "group": "Particle Monitoring - PM1 Level Control", "field": "high_limit_pm1_concentration_setpoint", "display": "Max PM1 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM1 Level Control", "field": "low_limit_pm1_concentration_setpoint", "display": "Min PM1 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM1 Level Control", "field": "pm1_concentration_detection_sensor", "display": "PM1 {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM10 Level Control", "field": "high_limit_pm10_concentration_setpoint", "display": "Max PM10 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM10 Level Control", "field": "low_limit_pm10_concentration_setpoint", "display": "Min PM10 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM10 Level Control", "field": "pm10_concentration_detection_sensor", "display": "PM10 {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM25 Level Control", "field": "high_limit_pm25_concentration_setpoint", "display": "Max PM25 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM25 Level Control", "field": "low_limit_pm25_concentration_setpoint", "display": "Min PM25 {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - PM25 Level Control", "field": "pm25_concentration_detection_sensor", "display": "PM25 {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - TVOC Level Control", "field": "high_limit_voc_concentration_setpoint", "display": "Max VOC {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - TVOC Level Control", "field": "low_limit_voc_concentration_setpoint", "display": "Min VOC {{suffix}} Setpt", "enums": ""}, {"type": "ahu", "group": "Particle Monitoring - TVOC Level Control", "field": "voc_concentration_detection_sensor", "display": "VOC {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Preheat Control", "field": "preheat_coil_air_leaving_temperature_sensor", "display": "Preheat Coil Leaving Temp", "enums": ""}, {"type": "ahu", "group": "Preheat Control", "field": "preheat_enable_command", "display": "Preheat Enable Cmd", "enums": "On, Off"}, {"type": "ahu", "group": "Preheat Control", "field": "preheat_percentage_command", "display": "Preheat Cmd", "enums": ""}, {"type": "ahu", "group": "Return Air CO2 Control", "field": "return_air_co2_concentration_sensor", "display": "Return Air CO2", "enums": ""}, {"type": "ahu", "group": "Return Air CO2 Control", "field": "return_air_co2_concentration_setpoint", "display": "Return Air CO2 Setpt", "enums": ""}, {"type": "ahu", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "ahu", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Steam Valve Control", "field": "steam_valve_percentage_command", "display": "Steam Valve Percent Cmd", "enums": ""}, {"type": "ahu", "group": "Steam Valve Control", "field": "steam_valve_percentage_sensor", "display": "Steam Valve Percent", "enums": ""}, {"type": "ahu", "group": "Zone And Building Air Pressure Control", "field": "building_air_static_pressure_sensor", "display": "Building Static Press", "enums": ""}, {"type": "ahu", "group": "Zone And Building Air Pressure Control", "field": "building_air_static_pressure_setpoint", "display": "Building Static Press Setpt", "enums": ""}, {"type": "ahu", "group": "Zone And Building Air Pressure Control", "field": "zone_air_static_pressure_sensor", "display": "Zone Static Press", "enums": ""}, {"type": "ahu", "group": "Zone And Building Air Pressure Control", "field": "zone_air_static_pressure_setpoint", "display": "Zone Static Press Setpt", "enums": ""}, {"type": "ahu", "group": "Zone CO2 Control", "field": "high_limit_zone_air_co2_concentration_setpoint", "display": "Max Zone CO2 Setpt", "enums": ""}, {"type": "ahu", "group": "Zone CO2 Control", "field": "low_limit_zone_air_co2_concentration_setpoint", "display": "Min Zone CO2 Setpt", "enums": ""}, {"type": "ahu", "group": "Zone CO2 Control", "field": "min_ventilation_deadband_co2_concentration_setpoint", "display": "Min Ventillation C02 Setpt", "enums": ""}, {"type": "ahu", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_sensor", "display": "Zone CO2", "enums": ""}, {"type": "ahu", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_setpoint", "display": "Zone CO2 Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "building_air_temperature_setpoint", "display": "Network Zone Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "device_control_mode", "display": "Setpt Mode", "enums": "Remote, No Remote"}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "effective_cooling_zone_air_temperature_setpoint", "display": "Eff Cooling Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "effective_heating_zone_air_temperature_setpoint", "display": "Eff Heating Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "effective_zone_air_temperature_setpoint", "display": "Eff Zone Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "occupied_cooling_zone_air_temperature_setpoint", "display": "Occ Cooling Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "occupied_heating_zone_air_temperature_setpoint", "display": "Occ Heating Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "temperature_offset_setpoint", "display": "Zone Temp Offset", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "unoccupied_cooling_zone_air_temperature_setpoint", "display": "UnOcc Cooling Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "unoccupied_heating_zone_air_temperature_setpoint", "display": "UnOcc Heating Temp Setpt", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "ahu", "group": "Zone Temperature Controls", "field": "zone_air_temperature_setpoint", "display": "Zone Temp Setpt", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "air_change_count", "display": "Air Changes", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "ongoing_total_air_change_count", "display": "Ongoing Air Changes", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "ongoing_total_outside_air_change_count", "display": "Ongoing Outside Air Changes", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "outside_air_change_count", "display": "Outside Air Changes", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "single_air_change_time_accumulator", "display": "Time Per Air Change", "enums": ""}, {"type": "airQuality", "group": "Air Changes Monitoring", "field": "single_outside_air_change_time_accumulator", "display": "Time Per Outside Air Change", "enums": ""}, {"type": "airQuality", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "airQuality", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "airQuality", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "airQuality", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "airQuality", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "airQuality", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "airQuality", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "airQuality", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "airQuality", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "airQuality", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Battery Level Monitoring", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "airQuality", "group": "CO Level Control - CO Level Control", "field": "co_concentration_detection_sensor", "display": "CO {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "CO Level Control - CO Level Control", "field": "high_limit_co_concentration_setpoint", "display": "Max CO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "CO Level Control - CO Level Control", "field": "low_limit_co_concentration_setpoint", "display": "Min CO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "CO2 Level Control - CO2 Level Control", "field": "co2_concentration_detection_sensor", "display": "CO2 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "CO2 Level Control - CO2 Level Control", "field": "high_limit_co2_concentration_setpoint", "display": "Max CO2 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "CO2 Level Control - CO2 Level Control", "field": "low_limit_co2_concentration_setpoint", "display": "Min CO2 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "Combustible Gas Level Control - Combustible Gas Level Control", "field": "gas_detection_percentage_sensor", "display": "Comb Gas {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Combustible Gas Level Control - Combustible Gas Level Control", "field": "high_limit_gas_percentage_setpoint", "display": "Max Comb Gas {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "Combustible Gas Level Control - Combustible Gas Level Control", "field": "low_limit_gas_percentage_setpoint", "display": "Min Comb Gas {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "airQuality", "group": "Exhaust Damper Control", "field": "exhaust_damper_command", "display": "Exhaust Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "airQuality", "group": "Exhaust Damper Control", "field": "exhaust_damper_status", "display": "Exhaust Damper {{suffix}} Status", "enums": "Open, Close"}, {"type": "airQuality", "group": "Exhaust Fan Control", "field": "exhaust_fan_command", "display": "Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Control", "field": "exhaust_fan_status", "display": "Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "high_exhaust_fan_speed_command", "display": "High Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "high_exhaust_fan_speed_status", "display": "High Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "low_exhaust_fan_speed_command", "display": "Low Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "low_exhaust_fan_speed_status", "display": "Low Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "medium_exhaust_fan_speed_command", "display": "Med Exhaust Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "airQuality", "group": "Exhaust Fan Staged Control", "field": "medium_exhaust_fan_speed_status", "display": "Med Exhaust Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "airQuality", "group": "HCHO Level Control - HCHO Level Control", "field": "hcho_concentration_detection_sensor", "display": "HCHO {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "HCHO Level Control - HCHO Level Control", "field": "high_limit_hcho_concentration_setpoint", "display": "Max HCHO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "HCHO Level Control - HCHO Level Control", "field": "low_limit_hcho_concentration_setpoint", "display": "Min HCHO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Light Intensity Control - Light Intensity Control", "field": "brightness_percentage_sensor", "display": "Light Intensity {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Light Intensity Control - Light Intensity Control", "field": "illuminance_sensor", "display": "Illuminance {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "NH3 Level Control - NH3 Level Control", "field": "high_limit_nh3_concentration_setpoint", "display": "Max NH3 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NH3 Level Control - NH3 Level Control", "field": "low_limit_nh3_concentration_setpoint", "display": "Min NH3 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NH3 Level Control - NH3 Level Control", "field": "nh3_concentration_detection_sensor", "display": "NH3 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "NO Level Control - NO Level Control", "field": "high_limit_no_concentration_setpoint", "display": "Max NO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NO Level Control - NO Level Control", "field": "low_limit_no_concentration_setpoint", "display": "Min NO {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NO Level Control - NO Level Control", "field": "no_concentration_detection_sensor", "display": "NO {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "NO2 Level Control - NO2 Level Control", "field": "high_limit_no2_concentration_setpoint", "display": "Max NO2 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NO2 Level Control - NO2 Level Control", "field": "low_limit_no2_concentration_setpoint", "display": "Min NO2 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "NO2 Level Control - NO2 Level Control", "field": "no2_concentration_detection_sensor", "display": "NO2 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "O3 Level Control - O3 Level Control", "field": "high_limit_o3_concentration_setpoint", "display": "Max O3 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "O3 Level Control - O3 Level Control", "field": "low_limit_o3_concentration_setpoint", "display": "Min O3 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "O3 Level Control - O3 Level Control", "field": "o3_concentration_detection_sensor", "display": "O3 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "PM1 Level Control - PM1 Level Control", "field": "high_limit_pm1_concentration_setpoint", "display": "Max PM1 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM1 Level Control - PM1 Level Control", "field": "low_limit_pm1_concentration_setpoint", "display": "Min PM1 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM1 Level Control - PM1 Level Control", "field": "pm1_concentration_detection_sensor", "display": "PM1 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "PM10 Level Control - PM10 Level Control", "field": "high_limit_pm10_concentration_setpoint", "display": "Max PM10 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM10 Level Control - PM10 Level Control", "field": "low_limit_pm10_concentration_setpoint", "display": "Min PM10 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM10 Level Control - PM10 Level Control", "field": "pm10_concentration_detection_sensor", "display": "PM10 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "PM25 Level Control - PM25 Level Control", "field": "high_limit_pm25_concentration_setpoint", "display": "Max PM25 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM25 Level Control - PM25 Level Control", "field": "low_limit_pm25_concentration_setpoint", "display": "Min PM25 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM25 Level Control - PM25 Level Control", "field": "pm25_concentration_detection_sensor", "display": "PM25 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "PM4 Level Control - PM4 Level Control", "field": "high_limit_pm4_concentration_setpoint", "display": "Max PM4 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM4 Level Control - PM4 Level Control", "field": "low_limit_pm4_concentration_setpoint", "display": "Min PM4 {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "PM4 Level Control - PM4 Level Control", "field": "pm4_concentration_detection_sensor", "display": "PM4 {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Refrigerant Level Control - Refrigerant Level Control", "field": "high_limit_refrigerant_concentration_setpoint", "display": "Max Refrigerant {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "Refrigerant Level Control - Refrigerant Level Control", "field": "refrigerant_concentration_detection_sensor", "display": "Refrigerant Detection {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Satisfaction Monitoring", "field": "satisfaction_percentage_sensor", "display": "Tenant Satisfaction", "enums": ""}, {"type": "airQuality", "group": "Sound Intensity Control - Sound Intensity Control", "field": "noise_sensor", "display": "Noise Level {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "TVOC Level Control - TVOC Level Control", "field": "high_limit_voc_concentration_setpoint", "display": "Max VOC {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "TVOC Level Control - TVOC Level Control", "field": "low_limit_voc_concentration_setpoint", "display": "Min VOC {{suffix}} Setpt", "enums": ""}, {"type": "airQuality", "group": "TVOC Level Control - TVOC Level Control", "field": "voc_concentration_detection_sensor", "display": "VOC {{suffix}}", "enums": ""}, {"type": "airQuality", "group": "Window Status - Window Status", "field": "window_status", "display": "Window {{suffix}} Status", "enums": ""}, {"type": "airQuality", "group": "Zone Air Pressure Monitoring", "field": "zone_air_static_pressure_sensor", "display": "Zone Static Press", "enums": ""}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_down_command", "display": "Audio Down Cmd {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_mute_command", "display": "Audio Mute Cmd {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_mute_sensor", "display": "Audio Mute Sensor {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_percentage_command", "display": "Audio Percentage Cmd {{suffix}}", "enums": ""}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_percentage_sensor", "display": "Audio Percentage Sensor {{suffix}}", "enums": ""}, {"type": "av", "group": "Audio System - Audio System", "field": "audio_up_command", "display": "Audio Up Cmd {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Input Source - Input Source", "field": "input_source_label", "display": "Input Source Label {{suffix}}", "enums": ""}, {"type": "av", "group": "Input Source - Input Source", "field": "input_source_status", "display": "Input Source Status {{suffix}}", "enums": ""}, {"type": "av", "group": "Screen System - Screen System", "field": "screen_label", "display": "Screen Label {{suffix}}", "enums": ""}, {"type": "av", "group": "Screen System - Screen System", "field": "screen_off_command", "display": "Screen Off Cmd {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Screen System - Screen System", "field": "screen_on_command", "display": "Screen On Cmd {{suffix}}", "enums": "On, Off"}, {"type": "av", "group": "Screen System - Screen System", "field": "screen_status", "display": "Screen Status {{suffix}}", "enums": "On, Off"}, {"type": "blinds", "group": "Battery Level Monitoring", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "blinds", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "blinds", "group": "High Priority Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "blinds", "group": "Low Priority Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "blinds", "group": "Medium Priority Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "blinds", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "blinds", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "blinds", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "blinds", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "blinds", "group": "Shade Tilt Control", "field": "tilt_command", "display": "Tilt Cmd", "enums": ""}, {"type": "blinds", "group": "Shade Tilt Control", "field": "tilt_status", "display": "Tilt Status", "enums": ""}, {"type": "blinds", "group": "Zone Temperature Monitoring", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "blinds", "group": "Zone Temperature Monitoring", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "boiler", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "boiler", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "boiler", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "boiler", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "boiler", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boiler", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boiler", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boiler", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Device Control or Status", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "boiler", "group": "Device Control or Status", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "boiler", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "boiler", "group": "Electric Heat Controls - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Electric Heat Controls - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Electric Heat Controls - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "boiler", "group": "Gas Heat Controls - Gas Valve Percentage Control", "field": "gas_heater_percentage_command", "display": "Gas Valve {{suffix}} Percent Cmd", "enums": ""}, {"type": "boiler", "group": "Gas Heat Controls - Gas Valve Percentage Monitoring", "field": "gas_heater_percentage_sensor", "display": "Gas Valve {{suffix}} Percent", "enums": ""}, {"type": "boiler", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_command", "display": "Gas Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_enable_command", "display": "Gas Heat Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Gas Heat Controls - Staged Gas Heating Monitoring", "field": "gas_heater_stage_status", "display": "Gas Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "boiler", "group": "Header Water Temperature Monitoring", "field": "header_water_entering_temperature_sensor", "display": "Entering Header Water Temp", "enums": ""}, {"type": "boiler", "group": "Header Water Temperature Monitoring", "field": "header_water_leaving_temperature_sensor", "display": "Leaving Header Water Temp", "enums": ""}, {"type": "boiler", "group": "Header Water Temperature Monitoring", "field": "header_water_leaving_temperature_setpoint", "display": "Leaving Header Water Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "high_limit_hot_water_leaving_temperature_setpoint", "display": "Max Hot Water Leaving Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_differential_pressure_sensor", "display": "Diff Hot Water Press", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_entering_temperature_sensor", "display": "Entering Hot Water Temp", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_flowrate_sensor", "display": "Hot Water Flow", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_flowrate_setpoint", "display": "Hot Water Flow Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_isolation_valve_run_command", "display": "Hot Water Iso Valve Cmd", "enums": "Open, Close"}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_isolation_valve_run_status", "display": "Hot Water Iso Valve Status", "enums": "Open, Close"}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_leaving_temperature_sensor", "display": "Leaving Hot Water Temp", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_leaving_temperature_setpoint", "display": "Leaving Hot Water Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_pressure_differential_setpoint", "display": "Diff Hot Water Press Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_pressure_sensor", "display": "Hot Water Press", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_pressure_setpoint", "display": "Hot Water Press Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_closed_command", "display": "Valve Closed Cmd", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_command", "display": "Hot Water Valve Cmd", "enums": "Open, Close"}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_open_command", "display": "Valve Open Cmd", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_percentage_command", "display": "Hot Water Valve Percent Cmd", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_percentage_sensor", "display": "Hot Water Valve Percent", "enums": ""}, {"type": "boiler", "group": "Hot Water", "field": "hot_water_valve_status", "display": "Hot Water Valve Status", "enums": "Open, Close"}, {"type": "boiler", "group": "Hot Water", "field": "low_limit_hot_water_leaving_temperature_setpoint", "display": "Min Hot Water Leaving Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_enable_command", "display": "Hot Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_percentage_command", "display": "Hot Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "boiler", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_command", "display": "Hot Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_current_sensor", "display": "Hot Water Pump {{suffix}} Current", "enums": ""}, {"type": "boiler", "group": "Hot Water - Hot Water Pump", "field": "hot_water_pump_run_status", "display": "Hot Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "boiler", "group": "Lead/Lag Control", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "boiler", "group": "Lead/Lag Control", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "boiler", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "boiler", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "boiler", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "boiler", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "boiler", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "boiler", "group": "Pumps part of the Boiler system.", "field": "central_heating_water_pump_run_status", "display": "Central Hot Water Pump Status", "enums": "On, Off"}, {"type": "boiler", "group": "Pumps part of the Boiler system.", "field": "domestic_hot_water_pump_run_status", "display": "Domestic Hot Water Pump Status", "enums": "On, Off"}, {"type": "boiler", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "boiler", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "boiler", "group": "Source Control", "field": "source_mode", "display": "Source Mode", "enums": ""}, {"type": "boiler", "group": "Tank Temperature Control", "field": "tank_water_temperature_sensor", "display": "Tank Water Temp", "enums": ""}, {"type": "boiler", "group": "Tank Temperature Control", "field": "tank_water_temperature_setpoint", "display": "Tank Water Temp Setpt", "enums": ""}, {"type": "boosterPump", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "boosterPump", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "boosterPump", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "boosterPump", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "boosterPump", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "boosterPump", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "boosterPump", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boosterPump", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boosterPump", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "boosterPump", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Lead/Lag Control", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "boosterPump", "group": "Lead/Lag Control", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "boosterPump", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "boosterPump", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "boosterPump", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "boosterPump", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "boosterPump", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "boosterPump", "group": "Pressure Monitoring", "field": "differential_water_pressure_sensor", "display": "Diff Water Press", "enums": ""}, {"type": "boosterPump", "group": "Pressure Monitoring", "field": "differential_water_pressure_setpoint", "display": "Diff Water Press Setpt", "enums": ""}, {"type": "boosterPump", "group": "Pressure Monitoring", "field": "entering_water_pressure_sensor", "display": "Entering Water Press", "enums": ""}, {"type": "boosterPump", "group": "Pressure Monitoring", "field": "leaving_water_pressure_sensor", "display": "Leaving Water Press", "enums": ""}, {"type": "boosterPump", "group": "Pressure Monitoring", "field": "leaving_water_pressure_setpoint", "display": "Leaving Water Press Setpt", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_angularvelocity_command", "display": "RPM Cmd {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_angularvelocity_sensor", "display": "RPM {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_frequency_command", "display": "Run Freq Cmd {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_frequency_sensor", "display": "Run Freq {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "boosterPump", "group": "Staged Pump - Pump Stages", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "bridge", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "camera", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "camera", "group": "Equipment", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "cav", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "cav", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "cav", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "cav", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "cav", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "cav", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "cav", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "cav", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "cav", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "cav", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "cav", "group": "Discharge Air Pressure Monitoring", "field": "discharge_air_pressure_sensor", "display": "Discharge Air Press", "enums": ""}, {"type": "cav", "group": "Discharge Air Pressure Monitoring", "field": "zone_inlet_discharge_air_pressure_sensor", "display": "Floor Supply Press", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "cold_deck_air_flowrate_sensor", "display": "Cold Deck Air Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "cold_deck_air_flowrate_setpoint", "display": "Cold Deck Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "cold_deck_air_pressure_sensor", "display": "Cold Deck Air Press", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_sensor", "display": "Discharge Air Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_setpoint", "display": "Discharge Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "effective_discharge_air_flowrate_setpoint", "display": "Eff Discharge Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "hot_deck_air_flowrate_sensor", "display": "Hot Deck Air Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "hot_deck_air_flowrate_setpoint", "display": "Hot Deck Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "hot_deck_air_pressure_sensor", "display": "Hot Deck Air Press", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_discharge_air_flowrate_setpoint", "display": "Max Discharge Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_occupied_cold_air_flowrate_setpoint", "display": "Max Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Max Occ Cooling Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_occupied_heating_discharge_air_flowrate_setpoint", "display": "Max Occ Heating Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_occupied_hot_air_flowrate_setpoint", "display": "Max Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_unoccupied_cold_air_flowrate_setpoint", "display": "Max UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Max UnOcc Cooling Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Max UnOcc Heating Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "max_unoccupied_hot_air_flowrate_setpoint", "display": "Max UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_discharge_air_flowrate_setpoint", "display": "Min Discharge Air Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_occupied_cold_air_flowrate_setpoint", "display": "Min Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Min Occ Cooling Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_occupied_heating_discharge_air_flowrate_setpoint", "display": "Min Occ Heating Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_occupied_hot_air_flowrate_setpoint", "display": "Min Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_unoccupied_cold_air_flowrate_setpoint", "display": "Min UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Min UnOcc Cooling Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Min UnOcc Heating Flow", "enums": ""}, {"type": "cav", "group": "Discharge Airflow Control", "field": "min_unoccupied_hot_air_flowrate_setpoint", "display": "Min UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "balancing_damper_percentage_command", "display": "Balancing Damper Percent Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "cold_deck_damper_percentage_command", "display": "Cold Deck Damper Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "cold_deck_damper_percentage_sensor", "display": "Cold Deck Damper Status", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_closed_command", "display": "Damper Closed Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_command", "display": "Discharge Damper Cmd", "enums": "Open, Close"}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_open_command", "display": "Damper Open Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_percentage_command", "display": "Discharge Damper Percent Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_percentage_sensor", "display": "Discharge Damper Percent", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "discharge_damper_status", "display": "Discharge Damper Status", "enums": "Open, Close"}, {"type": "cav", "group": "Discharge Damper", "field": "floor_damper_command", "display": "Floor Damper Cmd", "enums": "Open, Close"}, {"type": "cav", "group": "Discharge Damper", "field": "floor_damper_status", "display": "Floor Damper Status", "enums": "Open, Close"}, {"type": "cav", "group": "Discharge Damper", "field": "hot_deck_damper_percentage_command", "display": "Hot Deck Damper Percent Cmd", "enums": ""}, {"type": "cav", "group": "Discharge Damper", "field": "hot_deck_damper_percentage_sensor", "display": "Hot Deck Damper Percent", "enums": ""}, {"type": "cav", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "cav", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "cav", "group": "HVAC Device Control", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "cav", "group": "HVAC Device Control", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "cav", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "cav", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "cav", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "cav", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "cav", "group": "Window Status - Window Status", "field": "window_status", "display": "Window {{suffix}} Status", "enums": ""}, {"type": "cav", "group": "Zone CO2 Control", "field": "high_limit_zone_air_co2_concentration_setpoint", "display": "Max Zone CO2 Setpt", "enums": ""}, {"type": "cav", "group": "Zone CO2 Control", "field": "low_limit_zone_air_co2_concentration_setpoint", "display": "Min Zone CO2 Setpt", "enums": ""}, {"type": "cav", "group": "Zone CO2 Control", "field": "min_ventilation_deadband_co2_concentration_setpoint", "display": "Min Ventillation C02 Setpt", "enums": ""}, {"type": "cav", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_sensor", "display": "Zone CO2", "enums": ""}, {"type": "cav", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_setpoint", "display": "Zone CO2 Setpt", "enums": ""}, {"type": "chargingStation", "group": "Electric Charger - Electric Charger", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "chargingStation", "group": "Electric Charger - Electric Charger - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "chargingStation", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "chiller", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "chiller", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "chiller", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "chiller", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "chiller", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "chiller", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "chiller", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "chiller", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_differential_pressure_sensor", "display": "Diff Chilled Water Press", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_differential_pressure_setpoint", "display": "Diff Chilled Water Press Setpt", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_differential_temperature_sensor", "display": "Diff Chilled Water Temp", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_entering_temperature_sensor", "display": "Entering Chilled Water Temp", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_flowrate_sensor", "display": "Chilled Water Flow", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_flowrate_setpoint", "display": "Chilled Water Flow Setpt", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_isolation_valve_run_command", "display": "Chilled Water Iso Valve Cmd", "enums": "Open, Close"}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_isolation_valve_run_status", "display": "Chilled Water Iso Valve Status", "enums": "Open, Close"}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_leaving_temperature_sensor", "display": "Leaving Chilled Water Temp", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_leaving_temperature_setpoint", "display": "Leaving Chilled Water Temp Setpt", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_pressure_sensor", "display": "Chilled Water Press", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_pressure_setpoint", "display": "Chilled Water Press Setpt", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_valve_command", "display": "Chilled Water Valve Cmd", "enums": "Open, Close"}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_valve_percentage_command", "display": "Chilled Water Valve Percent Cmd", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_valve_percentage_sensor", "display": "Chilled Water Valve Percent", "enums": ""}, {"type": "chiller", "group": "Chilled Water", "field": "chilled_water_valve_status", "display": "Chilled Water Valve Status", "enums": "Open, Close"}, {"type": "chiller", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_enable_command", "display": "Chilled Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_percentage_command", "display": "Chilled Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "chiller", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_command", "display": "Chilled Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_current_sensor", "display": "Chilled Water Pump {{suffix}} Current", "enums": ""}, {"type": "chiller", "group": "Chilled Water - Chilled Water Pump", "field": "chilled_water_pump_run_status", "display": "Chilled Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_differential_pressure_sensor", "display": "Diff Cond Water Press", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_differential_pressure_setpoint", "display": "Diff Cond Water Press Setpt", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_differential_temperature_sensor", "display": "Diff Cond Water Temp", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_entering_temperature_sensor", "display": "Entering Cond Water Temp", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_flowrate_sensor", "display": "Cond Water Flow", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_flowrate_setpoint", "display": "Cond Water Flow Setpt", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_command", "display": "Cond Water Iso Valve Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_status", "display": "Cond Water Iso Valve Status", "enums": "On, Off"}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_sensor", "display": "Leaving Cond Water Temp", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_setpoint", "display": "Leaving Cond Water Temp Setpt", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_pressure_sensor", "display": "Cond Water Press", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_pressure_setpoint", "display": "Cond Water Press Setpt", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_valve_command", "display": "Cond Water Valve Cmd", "enums": "Open, Close"}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_valve_percentage_command", "display": "Cond Water Valve Percent Cmd", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_valve_percentage_sensor", "display": "Cond Water Valve Percent", "enums": ""}, {"type": "chiller", "group": "Condenser Water", "field": "condensing_water_valve_status", "display": "Cond Water Valve Status", "enums": "Open, Close"}, {"type": "chiller", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_enable_command", "display": "Cond Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_percentage_command", "display": "Cond Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "chiller", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_command", "display": "Cond Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_current_sensor", "display": "Cond Water Pump {{suffix}} Current", "enums": ""}, {"type": "chiller", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_status", "display": "Cond Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "chiller", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "chiller", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "chiller", "group": "Inlet Guide Vanes Position Monitoring - Inlet Guide Vanes Position Monitoring", "field": "inlet_guidevane_angle_sensor", "display": "Inlet GuideVane Angle", "enums": ""}, {"type": "chiller", "group": "Inlet Guide Vanes Position Monitoring - Inlet Guide Vanes Position Monitoring", "field": "inlet_guidevane_percentage_sensor", "display": "Inlet GuideVane Position", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_angularvelocity_sensor", "display": "Variable Comp {{suffix}} RPM {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_frequency_sensor", "display": "Variable Comp {{suffix}} Freq {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_run_command", "display": "Variable Comp {{suffix}} Cmd {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_run_status", "display": "Variable Comp {{suffix}} Status {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_command", "display": "Variable Comp {{suffix}} Percent Cmd {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_sensor", "display": "Variable Comp {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "chiller", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "chiller", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "chiller", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "chiller", "group": "Oil Pump Monitoring", "field": "oil_pump_status", "display": "Oil Pump Status", "enums": "On, Off"}, {"type": "chiller", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "chiller", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "chiller", "group": "Purge Monitoring", "field": "purge_compressor_status", "display": "Purge Comp Status", "enums": ""}, {"type": "chiller", "group": "Purge Monitoring", "field": "purge_liquid_valve_status", "display": "Purge Liquid Valve", "enums": "Open, Close"}, {"type": "chiller", "group": "Purge Monitoring", "field": "purge_status", "display": "Purge Status", "enums": ""}, {"type": "chiller", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "chiller", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "chiller", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_discharge_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Discharge Press", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_discharge_line_temperature_sensor", "display": "Comp {{suffix}} Discharge Temp", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_enable_command", "display": "Comp {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_enable_status", "display": "Comp {{suffix}} Enabled", "enums": "On, Off"}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_run_time_accumulator", "display": "Comp {{suffix}} Total Runtime", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_start_counter", "display": "Comp {{suffix}} Start Total", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_suction_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Suction Press", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_suction_line_temperature_sensor", "display": "Comp {{suffix}} Suction Temp", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "suction_line_temperature_sensor", "display": "Suction Temp {{suffix}}", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_command", "display": "Comp {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_current_sensor", "display": "Comp {{prefix}} Stage {{suffix}} Current", "enums": ""}, {"type": "chiller", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_status", "display": "Comp {{prefix}} Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "coolingTower", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "coolingTower", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "coolingTower", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "coolingTower", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "coolingTower", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "coolingTower", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "coolingTower", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "coolingTower", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Bypass Valve", "field": "bypass_valve_command", "display": "Bypass Valve Cmd", "enums": "Open, Close"}, {"type": "coolingTower", "group": "Bypass Valve", "field": "bypass_valve_percentage_command", "display": "Bypass Valve Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Bypass Valve", "field": "bypass_valve_percentage_sensor", "display": "Bypass Valve Percent", "enums": ""}, {"type": "coolingTower", "group": "Bypass Valve", "field": "bypass_valve_status", "display": "Bypass Valve Status", "enums": "Open, Close"}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_differential_pressure_sensor", "display": "Diff Cond Water Press", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_differential_pressure_setpoint", "display": "Diff Cond Water Press Setpt", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_differential_temperature_sensor", "display": "Diff Cond Water Temp", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_entering_temperature_sensor", "display": "Entering Cond Water Temp", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_flowrate_sensor", "display": "Cond Water Flow", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_flowrate_setpoint", "display": "Cond Water Flow Setpt", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_command", "display": "Cond Water Iso Valve Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_isolation_valve_run_status", "display": "Cond Water Iso Valve Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_sensor", "display": "Leaving Cond Water Temp", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_leaving_temperature_setpoint", "display": "Leaving Cond Water Temp Setpt", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_pressure_sensor", "display": "Cond Water Press", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_pressure_setpoint", "display": "Cond Water Press Setpt", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_valve_command", "display": "Cond Water Valve Cmd", "enums": "Open, Close"}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_valve_percentage_command", "display": "Cond Water Valve Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_valve_percentage_sensor", "display": "Cond Water Valve Percent", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water", "field": "condensing_water_valve_status", "display": "Cond Water Valve Status", "enums": "Open, Close"}, {"type": "coolingTower", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_enable_command", "display": "Cond Water Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_percentage_command", "display": "Cond Water Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_command", "display": "Cond Water Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_current_sensor", "display": "Cond Water Pump {{suffix}} Current", "enums": ""}, {"type": "coolingTower", "group": "Condenser Water - Condenser Water Pump", "field": "condensing_water_pump_run_status", "display": "Cond Water Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_angularvelocity_sensor", "display": "Cond Fan {{suffix}} RPM", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_current_sensor", "display": "Cond Fan {{suffix}} Current", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_energy_accumulator", "display": "Cond Fan {{suffix}} Total Energy", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_frequency_sensor", "display": "Cond Fan {{suffix}} Freq", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_mode", "display": "Cond Fan {{suffix}} Mode", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_power_sensor", "display": "Cond Fan {{suffix}} Power", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_run_time_accumulator", "display": "Cond Fan {{suffix}} Total Runtime", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_speed_percentage_command", "display": "Cond Fan {{suffix}} Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_speed_percentage_sensor", "display": "Cond Fan {{suffix}} Percent", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "high_condensing_fan_speed_command", "display": "High Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "high_condensing_fan_speed_status", "display": "High Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "low_condensing_fan_speed_command", "display": "Low Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "low_condensing_fan_speed_status", "display": "Low Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Condensing Fan", "field": "low_limit_condensing_fan_speed_percentage_command", "display": "Min Cond Fan Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "medium_condensing_fan_speed_command", "display": "Med Cond Fan {{suffix}} Cmd", "enums": ""}, {"type": "coolingTower", "group": "Condensing Fan", "field": "medium_condensing_fan_speed_status", "display": "Med Cond Fan {{suffix}} Status", "enums": ""}, {"type": "coolingTower", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "coolingTower", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "coolingTower", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "coolingTower", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "coolingTower", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "coolingTower", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "makeup_water_valve_percentage_command", "display": "Makeup Water Valve Percent Cmd", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_heating_command", "display": "Sump Heat Cmd", "enums": "On, Off"}, {"type": "coolingTower", "group": "Sump", "field": "sump_heating_current_sensor", "display": "Sump Heat Current", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_heating_percentage_sensor", "display": "Sump Heat Percent", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_heating_status", "display": "Sump Heat Status", "enums": "On, Off"}, {"type": "coolingTower", "group": "Sump", "field": "sump_level_sensor", "display": "Sump Level", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_level_setpoint", "display": "Sump Level Setpt", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_temperature_sensor", "display": "Sump Temp", "enums": ""}, {"type": "coolingTower", "group": "Sump", "field": "sump_temperature_setpoint", "display": "Sump Temp Setpt", "enums": ""}, {"type": "doorLock", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "doorLock", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "doorLock", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "doorLock", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "doorLock", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "doorLock", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "doorLock", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "doorLock", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "doorLock", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "doorLock", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "doorLock", "group": "Battery Level Monitoring", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "doorLock", "group": "Controller Status - Controller Status", "field": "controller_status", "display": "Controller {{suffix}} Status", "enums": ""}, {"type": "doorLock", "group": "Door Status - Door Status", "field": "door_status", "display": "Door {{suffix}} Status", "enums": "Open, Close"}, {"type": "doorLock", "group": "Lock Status - Lock Status", "field": "lock_status", "display": "Lock {{suffix}} Status", "enums": "On, Off"}, {"type": "electricityMonitoring", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "electricityMonitoring", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "electricityMonitoring", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "electricityMonitoring", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "electricityMonitoring", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "electricityMonitoring", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "electricityMonitoring", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "electricityMonitoring", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "electricityMonitoring", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "electricityMonitoring", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "electricityMonitoring", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "electricMeter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "electricMeter", "group": "Electrical Energy Monitoring", "field": "total_electric_energy_accumulator", "display": "Total Energy", "enums": ""}, {"type": "electricMeter", "group": "Electrical Energy Monitoring", "field": "total_reactive_electric_energy_accumulator", "display": "Total Reactive Energy", "enums": ""}, {"type": "electricMeter", "group": "Electrical Energy Monitoring - Differential Electrical Energy Monitoring", "field": "differential_electric_energy_accumulator", "display": "Total Diff Energy {{suffix}}", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "electricMeter", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "electricMeter", "group": "Peak Demand Monitoring", "field": "average_power_sensor", "display": "Averaged Power", "enums": ""}, {"type": "electricMeter", "group": "Peak Demand Monitoring", "field": "max_power_sensor", "display": "Peak Demand", "enums": ""}, {"type": "elevator", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "elevator", "group": "Container Mass Load", "field": "total_mass_sensor", "display": "Current Load", "enums": ""}, {"type": "elevator", "group": "Door Status - Door Status", "field": "door_status", "display": "Door {{suffix}} Status", "enums": "Open, Close"}, {"type": "elevator", "group": "High Priority Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "elevator", "group": "Low Priority Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "elevator", "group": "Medium Priority Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "elevator", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "elevator", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "elevator", "group": "Position", "field": "level_position_sensor", "display": "Current Position", "enums": ""}, {"type": "elevator", "group": "Position", "field": "next_level_position_sensor", "display": "Next Position", "enums": ""}, {"type": "elevator", "group": "Process Count - Process Count", "field": "ongoing_counter", "display": "Counter", "enums": ""}, {"type": "elevator", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "elevator", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "energyMeter", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "energyMeter", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "energyMeter", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "energyMeter", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "energyMeter", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "energyMeter", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "energyMeter", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "energyMeter", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "energyMeter", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "energyMeter", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "energyMeter", "group": "Cooling Energy Flow Monitoring - Cooling Energy Flow Monitoring", "field": "cooling_power_sensor", "display": "Cool Power {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Cooling Energy Flow Monitoring - Cooling Energy Flow Monitoring", "field": "differential_cooling_energy_accumulator", "display": "Diff Cool Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Cooling Energy Flow Monitoring - Cooling Energy Flow Monitoring", "field": "total_cooling_energy_accumulator", "display": "Cool Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Energy Flow Monitoring - Energy Flow Monitoring", "field": "differential_energy_accumulator", "display": "Diff Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Energy Flow Monitoring - Energy Flow Monitoring", "field": "total_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Heating Energy Flow Monitoring - Heating Energy Flow Monitoring", "field": "differential_heating_energy_accumulator", "display": "Diff Heat Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Heating Energy Flow Monitoring - Heating Energy Flow Monitoring", "field": "heating_power_sensor", "display": "Heat Power {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Heating Energy Flow Monitoring - Heating Energy Flow Monitoring", "field": "total_heating_energy_accumulator", "display": "Heat Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "High Limit Energy Flowrate Control - High Limit Energy Flowrate Control", "field": "high_limit_nominal_power_setpoint", "display": "Max Nominal Power Setpoint {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "High Limit Energy Flowrate Control - High Limit Energy Flowrate Control", "field": "high_limit_power_setpoint", "display": "Max Power Setpoint {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "High Limit Energy Flowrate Control - High Limit Energy Flowrate Control", "field": "power_sensor", "display": "Power", "enums": ""}, {"type": "energyMeter", "group": "High Limit Volumetric Flowrate Control", "field": "high_limit_flowrate_setpoint", "display": "Max Flow Setpt", "enums": ""}, {"type": "energyMeter", "group": "High Limit Volumetric Flowrate Control", "field": "high_limit_nominal_flowrate_setpoint", "display": "Max Nominal Flow Setpt", "enums": ""}, {"type": "energyMeter", "group": "High Limit Volumetric Flowrate Control", "field": "high_limit_percentage_setpoint", "display": "Max Percent Setpt", "enums": ""}, {"type": "energyMeter", "group": "High Limit Volumetric Flowrate Control", "field": "max_flowrate_setpoint", "display": "Max Flow Setpt", "enums": ""}, {"type": "energyMeter", "group": "High Limit Volumetric Flowrate Control - Volumetric Flowrate Monitoring", "field": "flowrate_sensor", "display": "Flow Rate {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "energyMeter", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Temperatures Control - Temperatures Control", "field": "return_temperature_sensor", "display": "Return Water Temp {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Temperatures Control - Temperatures Control", "field": "return_temperature_setpoint", "display": "Return Water Temp Setpt {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Temperatures Control - Temperatures Control", "field": "supply_temperature_sensor", "display": "Supply Water Temp {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Temperatures Control - Temperatures Control", "field": "supply_temperature_setpoint", "display": "Supply Water Temp Setpt {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_percentage_sensor", "display": "Valve {{suffix}} Percent", "enums": ""}, {"type": "energyMeter", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "energyMeter", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_command", "display": "Valve Cmd", "enums": ""}, {"type": "energyMeter", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "energyMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_cost_accumulator", "display": "Cost Accumulator", "enums": ""}, {"type": "energyMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_percentage_sensor", "display": "Differential Percentage", "enums": ""}, {"type": "energyMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_volume_accumulator", "display": "Diff Total Volume {{suffix}}", "enums": ""}, {"type": "energyMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "total_volume_accumulator", "display": "Total Volume {{suffix}}", "enums": ""}, {"type": "externalWeather", "group": "Cloud Cover/ Precipitation Monitoring", "field": "cloud_percentage_sensor", "display": "Cloud Coverage", "enums": ""}, {"type": "externalWeather", "group": "Cloud Cover/ Precipitation Monitoring", "field": "precipitation_label", "display": "Precipitation", "enums": ""}, {"type": "externalWeather", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "externalWeather", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "externalWeather", "group": "Wind Monitoring", "field": "wind_angle_sensor", "display": "Wind Angle", "enums": ""}, {"type": "externalWeather", "group": "Wind Monitoring", "field": "wind_linearvelocity_sensor", "display": "Wind Speed", "enums": ""}, {"type": "fan", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "fan", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "fan", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "fan", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "fan", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "fan", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "fan", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fan", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fan", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fan", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "discharge_air_pressure_sensor", "display": "Discharge Air Press", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "discharge_air_pressure_setpoint", "display": "Discharge Air Press Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "high_limit_discharge_air_pressure_setpoint", "display": "Max Discharge Press Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "low_limit_discharge_air_pressure_setpoint", "display": "Min Discharge Press Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "zone_inlet_discharge_air_pressure_sensor", "display": "Floor Supply Press", "enums": ""}, {"type": "fan", "group": "Discharge Air Pressure Control", "field": "zone_inlet_discharge_air_pressure_setpoint", "display": "Floor Supply Press Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_sensor", "display": "Discharge Air Flow", "enums": ""}, {"type": "fan", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_setpoint", "display": "Discharge Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Airflow Control", "field": "max_discharge_air_flowrate_setpoint", "display": "Max Discharge Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Airflow Control", "field": "min_discharge_air_flowrate_setpoint", "display": "Min Discharge Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Discharge Damper Control", "field": "discharge_damper_command", "display": "Discharge Damper Cmd", "enums": "Open, Close"}, {"type": "fan", "group": "Discharge Damper Control", "field": "discharge_damper_status", "display": "Discharge Damper Status", "enums": "Open, Close"}, {"type": "fan", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "fan", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "fan", "group": "Exhaust Airflow Control - Exhaust Airflow Control", "field": "exhaust_air_flowrate_sensor", "display": "Exhaust Air Flow {{suffix}}", "enums": ""}, {"type": "fan", "group": "Exhaust Airflow Control - Exhaust Airflow Control", "field": "exhaust_air_flowrate_setpoint", "display": "Exhaust Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Exhaust Airflow Control - Exhaust Airflow Control", "field": "max_exhaust_air_flowrate_setpoint", "display": "Max Exhaust Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Exhaust Airflow Control - Exhaust Airflow Control", "field": "min_exhaust_air_flowrate_setpoint", "display": "Min Exhaust Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Exhaust Damper Control", "field": "exhaust_damper_command", "display": "Exhaust Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "fan", "group": "Exhaust Damper Control", "field": "exhaust_damper_status", "display": "Exhaust Damper {{suffix}} Status", "enums": "Open, Close"}, {"type": "fan", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "fan", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "fan", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "fan", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "fan", "group": "Outside Airflow Control - Outside Airflow Control", "field": "max_outside_air_flowrate_setpoint", "display": "Max Outside Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Outside Airflow Control - Outside Airflow Control", "field": "min_outside_air_flowrate_setpoint", "display": "Min Outside Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Outside Airflow Control - Outside Airflow Control", "field": "outside_air_flowrate_sensor", "display": "Outside Air Flow {{suffix}}", "enums": ""}, {"type": "fan", "group": "Outside Airflow Control - Outside Airflow Control", "field": "outside_air_flowrate_setpoint", "display": "Outside Air Flow Setpt", "enums": ""}, {"type": "fan", "group": "Outside Damper Control", "field": "outside_damper_command", "display": "Outside Damper {{suffix}} Cmd", "enums": "Open, Close"}, {"type": "fan", "group": "Outside Damper Control", "field": "outside_damper_status", "display": "Outside Damper {{suffix}} Status", "enums": "Open, Close"}, {"type": "fan", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "fan", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "fan", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_command", "display": "RPM Cmd {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_sensor", "display": "RPM {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "fan", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "fan", "group": "Run Frequency Control", "field": "run_frequency_command", "display": "Run Freq Cmd {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Frequency Control", "field": "run_frequency_sensor", "display": "Run Freq {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "fan", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "fan", "group": "Staged Run Control", "field": "high_speed_command", "display": "High Speed Cmd", "enums": "On, Off"}, {"type": "fan", "group": "Staged Run Control", "field": "high_speed_status", "display": "High Speed Status", "enums": "On, Off"}, {"type": "fan", "group": "Staged Run Control", "field": "low_speed_command", "display": "Low Speed Cmd", "enums": "On, Off"}, {"type": "fan", "group": "Staged Run Control", "field": "low_speed_status", "display": "Low Speed Status", "enums": "On, Off"}, {"type": "fan", "group": "Staged Run Control", "field": "medium_speed_command", "display": "Med Speed Cmd", "enums": ""}, {"type": "fan", "group": "Staged Run Control", "field": "medium_speed_status", "display": "Med Speed Status", "enums": ""}, {"type": "fan", "group": "VFD Bypass Monitoring", "field": "vfd_bypass_status", "display": "VFD Bypass", "enums": "On, Off"}, {"type": "fan", "group": "Zone Temperature Control", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "fan", "group": "Zone Temperature Control", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "fan", "group": "Zone Temperature Control", "field": "zone_air_temperature_setpoint", "display": "Zone Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "cooling_coil_air_humidity_sensor", "display": "Cool Coil Air Humid", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "discharge_air_humidity_sensor", "display": "Discharge Air Humid", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "discharge_air_humidity_setpoint", "display": "Discharge Air Humid Setpt", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "heating_coil_air_humidity_sensor", "display": "Heat Coil Air Humid", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "return_air_dehumidification_setpoint", "display": "Return Air DeHumid Setpt", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "return_air_humidity_sensor", "display": "Return Air Humid", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "return_air_humidity_setpoint", "display": "Return Air Humid Setpt", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Air Humidity", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "fcu", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "fcu", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "fcu", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "fcu", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "fcu", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fcu", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fcu", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "fcu", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Chilled Water Valve", "field": "chilled_water_valve_command", "display": "Chilled Water Valve Cmd", "enums": "Open, Close"}, {"type": "fcu", "group": "Chilled Water Valve", "field": "chilled_water_valve_percentage_command", "display": "Chilled Water Valve Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Chilled Water Valve", "field": "chilled_water_valve_percentage_sensor", "display": "Chilled Water Valve Percent", "enums": ""}, {"type": "fcu", "group": "Chilled Water Valve", "field": "chilled_water_valve_status", "display": "Chilled Water Valve Status", "enums": "Open, Close"}, {"type": "fcu", "group": "Defrost Control", "field": "defrost_mode", "display": "Defrost Mode", "enums": "On, Off"}, {"type": "fcu", "group": "Defrost Control", "field": "defrost_status", "display": "Defrost Status", "enums": "On, Off"}, {"type": "fcu", "group": "Dehumidifier Control", "field": "dehumidifier_enable_command", "display": "DeHumid Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Dehumidifier Control", "field": "dehumidifier_run_command", "display": "DeHumid Cmd", "enums": ""}, {"type": "fcu", "group": "Dehumidifier Control", "field": "dehumidifier_run_percentage_command", "display": "DeHumid Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Dehumidifier Control", "field": "dehumidifier_run_status", "display": "DeHumid Status", "enums": "On, Off"}, {"type": "fcu", "group": "Discharge Airflow Monitoring", "field": "discharge_air_flowrate_sensor", "display": "Discharge Air Flow", "enums": ""}, {"type": "fcu", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_dewpoint_sensor", "display": "Discharge Air Dewpoint", "enums": ""}, {"type": "fcu", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_sensor", "display": "Discharge Air Temp", "enums": ""}, {"type": "fcu", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_setpoint", "display": "Discharge Air Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Discharge Temperature Control", "field": "high_limit_discharge_air_temperature_setpoint", "display": "Max Discharge Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Discharge Temperature Control", "field": "low_limit_discharge_air_temperature_setpoint", "display": "Min Discharge Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Dual Stage Controls", "field": "cooling_enable_command", "display": "Cool Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls", "field": "cooling_enable_status", "display": "Cool Enabled", "enums": ""}, {"type": "fcu", "group": "Dual Stage Controls", "field": "heating_enable_command", "display": "Heat Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls", "field": "heating_enable_status", "display": "Heat Enable", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls - Staged Cooling Control", "field": "cooling_stage_command", "display": "Cool Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls - Staged Cooling Control", "field": "cooling_stage_status", "display": "Cool Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls - Staged Heating Control", "field": "heating_stage_command", "display": "Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Dual Stage Controls - Staged Heating Control", "field": "heating_stage_status", "display": "Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "fcu", "group": "Electric Heat Controls - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Electric Heat Controls - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Electric Heat Controls - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "fcu", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "fcu", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "fcu", "group": "Gas Heat Controls - Gas Valve Percentage Control", "field": "gas_heater_percentage_command", "display": "Gas Valve {{suffix}} Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Gas Heat Controls - Gas Valve Percentage Monitoring", "field": "gas_heater_percentage_sensor", "display": "Gas Valve {{suffix}} Percent", "enums": ""}, {"type": "fcu", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_command", "display": "Gas Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_enable_command", "display": "Gas Heat Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Gas Heat Controls - Staged Gas Heating Monitoring", "field": "gas_heater_stage_status", "display": "Gas Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump", "field": "controller_cooling_output_percentage_label", "display": "Cool PID", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "controller_heating_output_percentage_label", "display": "Heat PID", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "fcu", "group": "Heat Pump", "field": "reversing_heating_cooling_valve_command", "display": "Rev Valve Cmd", "enums": "Cooling, Heating"}, {"type": "fcu", "group": "Heat Pump", "field": "reversing_heating_cooling_valve_status", "display": "Rev Valve", "enums": "Cooling, Heating"}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_angularvelocity_sensor", "display": "Variable Comp {{suffix}} RPM {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_frequency_sensor", "display": "Variable Comp {{suffix}} Freq {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_run_command", "display": "Variable Comp {{suffix}} Cmd {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_run_status", "display": "Variable Comp {{suffix}} Status {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_command", "display": "Variable Comp {{suffix}} Percent Cmd {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_sensor", "display": "Variable Comp {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_discharge_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Discharge Press", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_discharge_line_temperature_sensor", "display": "Comp {{suffix}} Discharge Temp", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_enable_command", "display": "Comp {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_enable_status", "display": "Comp {{suffix}} Enabled", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_run_time_accumulator", "display": "Comp {{suffix}} Total Runtime", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_start_counter", "display": "Comp {{suffix}} Start Total", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_suction_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Suction Press", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "compressor_suction_line_temperature_sensor", "display": "Comp {{suffix}} Suction Temp", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop", "field": "suction_line_temperature_sensor", "display": "Suction Temp {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_command", "display": "Comp {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_current_sensor", "display": "Comp {{prefix}} Stage {{suffix}} Current", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Compressor Loop - Stage Control", "field": "compressor_stage_status", "display": "Comp {{prefix}} Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_command", "display": "Cool Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_current_sensor", "display": "Cool Stage {{suffix}} Current", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Cooling Controls", "field": "compressor_cooling_stage_status", "display": "Cool Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_command", "display": "Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_current_sensor", "display": "Heat Stage {{suffix}} Current", "enums": ""}, {"type": "fcu", "group": "Heat Pump - Staged Heating Controls", "field": "compressor_heating_stage_status", "display": "Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_closed_command", "display": "Valve Closed Cmd", "enums": ""}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_command", "display": "Hot Water Valve Cmd", "enums": "Open, Close"}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_open_command", "display": "Valve Open Cmd", "enums": ""}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_command", "display": "Hot Water Valve Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_sensor", "display": "Hot Water Valve Percent", "enums": ""}, {"type": "fcu", "group": "Hot Water Valve", "field": "hot_water_valve_status", "display": "Hot Water Valve Status", "enums": "Open, Close"}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_enable_command", "display": "Humid Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_enable_percentage_command", "display": "Humid Enable Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_outside_air_temperature_enable_setpoint", "display": "Outside Temp Humid Setpt", "enums": ""}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_run_command", "display": "Humid Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_run_percentage_command", "display": "Humid Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_run_percentage_sensor", "display": "Humid Output", "enums": ""}, {"type": "fcu", "group": "Humidifier Control", "field": "humidifier_run_status", "display": "Humid Status", "enums": "On, Off"}, {"type": "fcu", "group": "Indoor Unit Variable Refrigerant Flow", "field": "expansion_valve_percentage_sensor", "display": "Expansion Valve Percent", "enums": ""}, {"type": "fcu", "group": "Indoor Unit Variable Refrigerant Flow", "field": "expansion_valve_status", "display": "Expansion Valve Status", "enums": "Open, Close"}, {"type": "fcu", "group": "Indoor Unit Variable Refrigerant Flow", "field": "gas_line_temperature_sensor", "display": "Gas Line Temp", "enums": ""}, {"type": "fcu", "group": "Indoor Unit Variable Refrigerant Flow", "field": "liquid_line_temperature_sensor", "display": "Liquid Line Temp", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "building_air_temperature_setpoint", "display": "Network Zone Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "device_control_mode", "display": "Setpt Mode", "enums": "Remote, No Remote"}, {"type": "fcu", "group": "Network Thermostat", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "fcu", "group": "Network Thermostat", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_angularvelocity_sensor", "display": "Discharge Fan RPM", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_command", "display": "Discharge Fan Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_current_sensor", "display": "Discharge Fan Current", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_enable_command", "display": "Discharge Fan Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_enable_status", "display": "Discharge Fan Enabled", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_energy_accumulator", "display": "Discharge Fan Total Energy", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_frequency_sensor", "display": "Discharge Fan Freq", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_mode", "display": "Discharge Fan Mode", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_power_sensor", "display": "Discharge Fan Power", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_run_time_accumulator", "display": "Discharge Fan Total Runtime", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_speed_percentage_command", "display": "Discharge Fan Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_speed_percentage_sensor", "display": "Discharge Fan Percent", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "discharge_fan_status", "display": "Discharge Fan Status", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "effective_cooling_zone_air_temperature_setpoint", "display": "Eff Cooling Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "effective_heating_zone_air_temperature_setpoint", "display": "Eff Heating Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "effective_zone_air_temperature_setpoint", "display": "Eff Zone Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "high_discharge_fan_speed_command", "display": "High Discharge Fan Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "high_discharge_fan_speed_status", "display": "High Discharge Fan Status", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "low_discharge_fan_speed_command", "display": "Low Discharge Fan Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "low_discharge_fan_speed_status", "display": "Low Discharge Fan Status", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "low_limit_discharge_fan_speed_percentage_command", "display": "Min Discharge Fan Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "medium_discharge_fan_speed_command", "display": "Med Discharge Fan Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Network Thermostat", "field": "medium_discharge_fan_speed_status", "display": "Med Discharge Fan Status", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "occupied_cooling_zone_air_temperature_setpoint", "display": "Occ Cooling Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "occupied_heating_zone_air_temperature_setpoint", "display": "Occ Heating Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "temperature_offset_setpoint", "display": "Zone Temp Offset", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "unoccupied_cooling_zone_air_temperature_setpoint", "display": "UnOcc Cooling Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "unoccupied_heating_zone_air_temperature_setpoint", "display": "UnOcc Heating Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Network Thermostat", "field": "zone_air_temperature_setpoint", "display": "Zone Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "fcu", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "fcu", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "fcu", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "fcu", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "fcu", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "fcu", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "fcu", "group": "Supplemental Heat Control", "field": "supplemental_heater_command", "display": "Sup Heat Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Supplemental Heat Control", "field": "supplemental_heater_enable_command", "display": "Sup Heat Enable Cmd", "enums": "On, Off"}, {"type": "fcu", "group": "Supplemental Heat Control", "field": "supplemental_heater_percentage_command", "display": "Sup Heat Percent Cmd", "enums": ""}, {"type": "fcu", "group": "Supplemental Heat Control", "field": "supplemental_heater_percentage_sensor", "display": "Sup Heat Percent", "enums": ""}, {"type": "fcu", "group": "Supply Temperature Control", "field": "supply_air_temperature_sensor", "display": "Supply Air Temp", "enums": ""}, {"type": "fcu", "group": "Supply Temperature Control", "field": "supply_air_temperature_setpoint", "display": "Supply Air Temp Setpt", "enums": ""}, {"type": "fcu", "group": "Window Status - Window Status", "field": "window_status", "display": "Window {{suffix}} Status", "enums": ""}, {"type": "fcu", "group": "Zone CO2 Control", "field": "high_limit_zone_air_co2_concentration_setpoint", "display": "Max Zone CO2 Setpt", "enums": ""}, {"type": "fcu", "group": "Zone CO2 Control", "field": "low_limit_zone_air_co2_concentration_setpoint", "display": "Min Zone CO2 Setpt", "enums": ""}, {"type": "fcu", "group": "Zone CO2 Control", "field": "min_ventilation_deadband_co2_concentration_setpoint", "display": "Min Ventillation C02 Setpt", "enums": ""}, {"type": "fcu", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_sensor", "display": "Zone CO2", "enums": ""}, {"type": "fcu", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_setpoint", "display": "Zone CO2 Setpt", "enums": ""}, {"type": "fire", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "fire", "group": "Fire - Fire Alarms", "field": "fire_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Alarm, Normal"}, {"type": "fire", "group": "Fire - Fire Bypass Status", "field": "fire_bypass_status", "display": "Fire Bypass {{suffix}}", "enums": "Alarm, Normal"}, {"type": "fire", "group": "Fire - Fire Faults", "field": "fire_fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Alarm, Normal"}, {"type": "fire", "group": "Fire - Fire Status", "field": "fire_status", "display": "{{fieldsInConnector.name}}", "enums": "Alarm, Normal"}, {"type": "fire", "group": "Fire - Fire Supervisory Status", "field": "fire_supervisory_status", "display": "{{fieldsInConnector.name}}", "enums": "Alarm, Normal"}, {"type": "gasMeter", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "gasMeter", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "gasMeter", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "gasMeter", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "gasMeter", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "gasMeter", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "gasMeter", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "gasMeter", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "gasMeter", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "gasMeter", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "gasMeter", "group": "Energy Flow Monitoring - Energy Flow Monitoring", "field": "differential_energy_accumulator", "display": "Diff Total Energy {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Energy Flow Monitoring - Energy Flow Monitoring", "field": "total_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Energy Flowrate Monitoring", "field": "power_sensor", "display": "Power", "enums": ""}, {"type": "gasMeter", "group": "Gas Temperature Monitoring - Gas Temperature Monitoring", "field": "gas_temperature_sensor", "display": "Gas Temp {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_cost_accumulator", "display": "Cost Accumulator", "enums": ""}, {"type": "gasMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_percentage_sensor", "display": "Differential Percentage", "enums": ""}, {"type": "gasMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_volume_accumulator", "display": "Diff Total Volume {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "total_volume_accumulator", "display": "Total Volume {{suffix}}", "enums": ""}, {"type": "gasMeter", "group": "Volumetric Flowrate Monitoring - Volumetric Flowrate Monitoring", "field": "flowrate_sensor", "display": "Flow Rate {{suffix}}", "enums": ""}, {"type": "generator", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "generator", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "generator", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "generator", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "generator", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "generator", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "generator", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "generator", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "generator", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "generator", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "generator", "group": "Battery Electricity Monitoring", "field": "battery_charge_current_sensor", "display": "Battery Charge Current", "enums": ""}, {"type": "generator", "group": "Battery Electricity Monitoring", "field": "battery_voltage_sensor", "display": "Battery Voltage", "enums": ""}, {"type": "generator", "group": "Coolant Monitoring", "field": "cooling_liquid_tank_percentage_sensor", "display": "Coolant Level", "enums": ""}, {"type": "generator", "group": "Coolant Monitoring", "field": "cooling_liquid_tank_volume_sensor", "display": "Coolant Volume", "enums": ""}, {"type": "generator", "group": "Coolant Monitoring", "field": "cooling_liquid_temperature_sensor", "display": "Coolant Temp", "enums": ""}, {"type": "generator", "group": "Device Control or Status", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "generator", "group": "Device Control or Status", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "generator", "group": "Fuel Level Monitoring", "field": "fuel_tank_percentage_sensor", "display": "Fuel Level", "enums": ""}, {"type": "generator", "group": "Oil Pressure Monitoring", "field": "oil_pressure_sensor", "display": "Oil Pressure", "enums": ""}, {"type": "generator", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "generator", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "generator", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "generator", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_command", "display": "RPM Cmd {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_sensor", "display": "RPM {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "generator", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "generator", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "heatExchanger", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "heatExchanger", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "heatExchanger", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "heatExchanger", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "heatExchanger", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "heatExchanger", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatExchanger", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatExchanger", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatExchanger", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "heatExchanger", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Primary Loop", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "heatExchanger", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "high_limit_secondary_loop_entering_temperature_setpoint", "display": "Max Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "high_limit_secondary_loop_leaving_temperature_setpoint", "display": "Max Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "low_limit_secondary_loop_entering_temperature_setpoint", "display": "Min Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "low_limit_secondary_loop_leaving_temperature_setpoint", "display": "Min Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_sensor", "display": "Sec Loop Diff Press", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_setpoint", "display": "Sec Loop Diff Press Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_differential_temperature_sensor", "display": "Sec Loop Diff Temp", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_sensor", "display": "Sec Loop Entering Temp", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_setpoint", "display": "Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_command", "display": "Sec Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_status", "display": "Sec Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_leaving_pressure_sensor", "display": "Sec Loop Leaving Press", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_sensor", "display": "Sec Loop Leaving Temp", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_setpoint", "display": "Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_pressure_sensor", "display": "Sec Loop Entering Press", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_pressure_setpoint", "display": "Sec Loop Entering Press Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_valve_command", "display": "Sec Loop Valve Cmd", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_command", "display": "Sec Loop Valve Percent Cmd", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_sensor", "display": "Sec Loop Valve Percent", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_valve_status", "display": "Sec Loop Valve Status", "enums": "Open, Close"}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_sensor", "display": "Sec Loop Water Flow", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_setpoint", "display": "Sec Loop Water Flow Setpt", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_enable_command", "display": "Sec Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_percentage_command", "display": "Sec Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_command", "display": "Sec Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "heatExchanger", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_current_sensor", "display": "Sec Loop Pump {{suffix}} Current", "enums": ""}, {"type": "heatExchanger", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_status", "display": "Sec Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "heatPump", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "heatPump", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "heatPump", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "heatPump", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "heatPump", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "heatPump", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "heatPump", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatPump", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatPump", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "heatPump", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "heatPump", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "heatPump", "group": "Heating Cooling Capacity and Request", "field": "cooling_output_percentage_capacity", "display": "Cooling Percent Capacity", "enums": ""}, {"type": "heatPump", "group": "Heating Cooling Capacity and Request", "field": "cooling_request_percentage_sensor", "display": "Clg Request Percent", "enums": ""}, {"type": "heatPump", "group": "Heating Cooling Capacity and Request", "field": "heating_output_percentage_capacity", "display": "Heating Percent Capacity", "enums": ""}, {"type": "heatPump", "group": "Heating Cooling Capacity and Request", "field": "heating_request_percentage_sensor", "display": "Htg Request Percent", "enums": ""}, {"type": "heatPump", "group": "HVAC Device Control", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "heatPump", "group": "HVAC Device Control", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_angularvelocity_sensor", "display": "Variable Comp {{suffix}} RPM {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_frequency_sensor", "display": "Variable Comp {{suffix}} Freq {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_run_command", "display": "Variable Comp {{suffix}} Cmd {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_run_status", "display": "Variable Comp {{suffix}} Status {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_command", "display": "Variable Comp {{suffix}} Percent Cmd {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Inverter Compressor Loop - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_sensor", "display": "Variable Comp {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "heatPump", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "heatPump", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "heatPump", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "heatPump", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "heatPump", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "heatPump", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "heatPump", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_discharge_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Discharge Press", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_discharge_line_temperature_sensor", "display": "Comp {{suffix}} Discharge Temp", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_enable_command", "display": "Comp {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_enable_status", "display": "Comp {{suffix}} Enabled", "enums": "On, Off"}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_run_time_accumulator", "display": "Comp {{suffix}} Total Runtime", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_start_counter", "display": "Comp {{suffix}} Start Total", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_suction_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Suction Press", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "compressor_suction_line_temperature_sensor", "display": "Comp {{suffix}} Suction Temp", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop", "field": "suction_line_temperature_sensor", "display": "Suction Temp {{suffix}}", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_command", "display": "Comp {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_current_sensor", "display": "Comp {{prefix}} Stage {{suffix}} Current", "enums": ""}, {"type": "heatPump", "group": "Staged Compressor Loop - Staged Compressor Loop - Stage Control", "field": "compressor_stage_status", "display": "Comp {{prefix}} Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "heatPump", "group": "Water Treatment", "field": "cooling_water_leaving_temperature_setpoint", "display": "Cooling Leaving Water Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "differential_water_pressure_sensor", "display": "Diff Water Press", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "differential_water_pressure_setpoint", "display": "Diff Water Press Setpt", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "effective_water_leaving_temperature_setpoint", "display": "Effective Leaving Water Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "entering_water_pressure_sensor", "display": "Entering Water Press", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "entering_water_temperature_sensor", "display": "Entering Water Temp", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "heating_water_leaving_temperature_setpoint", "display": "Heating Leaving Water Temp Setpt", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "leaving_water_pressure_sensor", "display": "Leaving Water Press", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "leaving_water_pressure_setpoint", "display": "Leaving Water Press Setpt", "enums": ""}, {"type": "heatPump", "group": "Water Treatment", "field": "leaving_water_temperature_sensor", "display": "Leaving Water Temp", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Recovery Water Leaving Temperature Monitoring", "field": "entering_recovery_water_temperature_sensor", "display": "Entering Recovery Water Temp", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Recovery Water Leaving Temperature Monitoring", "field": "leaving_recovery_water_temperature_sensor", "display": "Leaving Recovery Water Temp", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Filter Monitoring", "field": "filter_differential_water_pressure_sensor", "display": "Filter Diff Press", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Filter Monitoring", "field": "water_filter_alarm", "display": "Filter Alarm", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Pump Control", "field": "water_pump_run_command", "display": "Pump Cmd", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Pump Control", "field": "water_pump_run_status", "display": "Pump Status", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Pump Control - Recovery Water Pump Control", "field": "recovery_water_pump_run_command", "display": "Recovery Pump Cmd", "enums": ""}, {"type": "heatPump", "group": "Water Treatment - Water Pump Control - Recovery Water Pump Control", "field": "recovery_water_pump_run_status", "display": "Recovery Pump Status", "enums": ""}, {"type": "humidifier", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "humidifier", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "humidifier", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "humidifier", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "humidifier", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "humidifier", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "humidifier", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "humidifier", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "humidifier", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "humidifier", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Bypass Damper Control", "field": "bypass_damper_percentage_command", "display": "Bypass Damper {{suffix}} Percent Cmd", "enums": ""}, {"type": "humidifier", "group": "Bypass Damper Control", "field": "bypass_damper_percentage_sensor", "display": "Bypass Damper Sensor", "enums": ""}, {"type": "humidifier", "group": "Dehumidifier Control", "field": "dehumidifier_enable_command", "display": "DeHumid Enable Cmd", "enums": "On, Off"}, {"type": "humidifier", "group": "Dehumidifier Control", "field": "dehumidifier_run_command", "display": "DeHumid Cmd", "enums": ""}, {"type": "humidifier", "group": "Dehumidifier Control", "field": "dehumidifier_run_percentage_command", "display": "DeHumid Percent Cmd", "enums": ""}, {"type": "humidifier", "group": "Dehumidifier Control", "field": "dehumidifier_run_status", "display": "DeHumid Status", "enums": "On, Off"}, {"type": "humidifier", "group": "Discharge Air Humidity Control", "field": "cooling_coil_air_humidity_sensor", "display": "Cool Coil Air Humid", "enums": ""}, {"type": "humidifier", "group": "Discharge Air Humidity Control", "field": "discharge_air_humidity_sensor", "display": "Discharge Air Humid", "enums": ""}, {"type": "humidifier", "group": "Discharge Air Humidity Control", "field": "discharge_air_humidity_setpoint", "display": "Discharge Air Humid Setpt", "enums": ""}, {"type": "humidifier", "group": "Discharge Air Humidity Control", "field": "heating_coil_air_humidity_sensor", "display": "Heat Coil Air Humid", "enums": ""}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_enable_command", "display": "Humid Enable Cmd", "enums": "On, Off"}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_enable_percentage_command", "display": "Humid Enable Percent Cmd", "enums": ""}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_outside_air_temperature_enable_setpoint", "display": "Outside Temp Humid Setpt", "enums": ""}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_run_command", "display": "Humid Cmd", "enums": "On, Off"}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_run_percentage_command", "display": "Humid Percent Cmd", "enums": ""}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_run_percentage_sensor", "display": "Humid Output", "enums": ""}, {"type": "humidifier", "group": "Humidifier Control", "field": "humidifier_run_status", "display": "Humid Status", "enums": "On, Off"}, {"type": "humidifier", "group": "Humidifier Mass Flowrate Monitoring", "field": "entering_water_valve_status", "display": "Entering Water Valve Status", "enums": "Open, Close"}, {"type": "humidifier", "group": "Humidifier Mass Flowrate Monitoring", "field": "humidifier_massflowrate_sensor", "display": "Humid Mass Flow Sensor", "enums": ""}, {"type": "humidifier", "group": "Humidifier Mass Flowrate Monitoring", "field": "leaving_water_valve_status", "display": "Leaving Water Valve Status", "enums": "Open, Close"}, {"type": "humidifier", "group": "Humidifier Mass Flowrate Monitoring", "field": "steam_valve_status", "display": "Steam Valve", "enums": "Open, Close"}, {"type": "humidifier", "group": "Humidifier Mass Flowrate Monitoring", "field": "ventilation_fan_status", "display": "Ventillation Fan Status", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "demand_percentage_sensor", "display": "Burner {{suffix}} Demand Percent", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "fan_frequency_sensor", "display": "Burner {{suffix}} Fan Freq", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "flue_temperature_sensor", "display": "Tank {{suffix}} Chimney Temp", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "foam_detection_percentage_sensor", "display": "Tank {{suffix}} Foam Probe", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "water_percentage_sensor", "display": "Tank {{suffix}} Water Percent", "enums": ""}, {"type": "humidifier", "group": "Humidifier Tank - Humidifier Tank", "field": "water_temperature_sensor", "display": "Tank {{suffix}} Water Temp", "enums": ""}, {"type": "humidifier", "group": "Reactivation Air Temperature Control", "field": "reactivation_air_temperature_sensor", "display": "React Air Temp", "enums": ""}, {"type": "humidifier", "group": "Reactivation Air Temperature Control", "field": "reactivation_air_temperature_setpoint", "display": "React Air Temp Setpt", "enums": ""}, {"type": "humidifier", "group": "Zone Humidity Control", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Zone Humidity Control", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Zone Humidity Control", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Zone Humidity Control", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "humidifier", "group": "Zone Humidity Control", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "IOREADER", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "IOREADER", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "IOREADER", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "IOREADER", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "IOREADER", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "IOREADER", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "IOREADER", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "IOREADER", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "IOREADER", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "IOREADER", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "IOREADER", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "IOREADER", "group": "Current Alarm Count", "field": "ongoing_event_counter", "display": "Alarms Counter", "enums": ""}, {"type": "IOREADER", "group": "External (Fiber)glass Temperature Monitoring", "field": "external_frame_temperature_sensor", "display": "Frame Temp Ext", "enums": ""}, {"type": "IOREADER", "group": "External (Fiber)glass Temperature Monitoring", "field": "external_glass_temperature_sensor", "display": "Glass Temp Ext", "enums": ""}, {"type": "IOREADER", "group": "External Air Temperature Monitoring", "field": "external_air_temperature_sensor", "display": "External Temp Int", "enums": ""}, {"type": "IOREADER", "group": "Glass Solar Flux Monitoring", "field": "external_glass_solar_flux_sensor", "display": "Solar Panel Irradiance Ext", "enums": ""}, {"type": "IOREADER", "group": "Glass Solar Flux Monitoring", "field": "internal_glass_solar_flux_sensor", "display": "Solar Panel Irradiance Int", "enums": ""}, {"type": "IOREADER", "group": "Glass Solar Flux Monitoring", "field": "internal_glass_solar_level_sensor", "display": "Solar Cell Tsol", "enums": ""}, {"type": "IOREADER", "group": "Insulated Panel Temperature Monitoring", "field": "insulated_controller_temperature_sensor", "display": "Insulated Panel Temp", "enums": ""}, {"type": "IOREADER", "group": "Internal (Fiber)glass Temperature Monitoring", "field": "internal_frame_thermocouple_temperature_sensor", "display": "Frame Heat Flux Thermocouple Int", "enums": ""}, {"type": "IOREADER", "group": "Internal (Fiber)glass Temperature Monitoring", "field": "internal_glass_thermocouple_temperature_sensor", "display": "Glass Heat Flux Thermocouple Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Air Temperature Monitoring", "field": "internal_air_temperature_sensor", "display": "Air Temp Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Glass Heating Flux Monitoring", "field": "internal_frame_heating_flux_sensor", "display": "Frame Heat Flux Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Glass Heating Flux Monitoring", "field": "internal_glass_heating_flux_sensor", "display": "Glass Heat Flux Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Glass Temperature Monitoring", "field": "internal_frame_temperature_sensor", "display": "Frame Temp Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Glass Temperature Monitoring", "field": "internal_glass_temperature_sensor", "display": "Glass Temp Int", "enums": ""}, {"type": "IOREADER", "group": "Internal Glass Temperature Monitoring", "field": "internal_wemsfilm_temperature_sensor", "display": "WEMS Film Temp Int", "enums": ""}, {"type": "IOREADER", "group": "Internal-External Temperature Delta Monitoring", "field": "internal_external_differential_air_temperature_sensor", "display": "Ti-To", "enums": ""}, {"type": "IOREADER", "group": "Pyranometer Flux Monitoring", "field": "external_glass_pyranometer_flux_sensor", "display": "Pyranometer Ext", "enums": ""}, {"type": "IOREADER", "group": "Pyranometer Flux Monitoring", "field": "internal_glass_pyranometer_flux_sensor", "display": "Pyranometer Int", "enums": ""}, {"type": "IOREADER", "group": "Pyranometer Flux Monitoring", "field": "internal_glass_pyranometer_level_sensor", "display": "Pyranometer Tsol", "enums": ""}, {"type": "IOREADER", "group": "Pyranometer Monitoring", "field": "external_glass_pyrgeometer_flux_sensor", "display": "Pyrgeometer Ext", "enums": ""}, {"type": "IOREADER", "group": "Pyranometer Monitoring", "field": "external_glass_pyrgeometer_temperature_sensor", "display": "Pyrgeometer Thermistor Ext", "enums": ""}, {"type": "IOREADER", "group": "R Factor", "field": "thermal_resistance_sensor", "display": "Thermal Resistance", "enums": ""}, {"type": "IOREADER", "group": "U Factor", "field": "thermal_flux_sensor", "display": "U-Factor", "enums": ""}, {"type": "IOREADER", "group": "Wind Monitoring", "field": "wind_angle_sensor", "display": "Wind Angle", "enums": ""}, {"type": "IOREADER", "group": "Wind Monitoring", "field": "wind_linearvelocity_sensor", "display": "Wind Speed", "enums": ""}, {"type": "leakDetection", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "leakDetection", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "leakDetection", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "leakDetection", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "leakDetection", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "leakDetection", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "leakDetection", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "leakDetection", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "leakDetection", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "leakDetection", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "leakDetection", "group": "Battery Level Monitoring", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "leakDetection", "group": "Battery Monitoring", "field": "battery_fault_status", "display": "Battery Fault Sensor", "enums": ""}, {"type": "leakDetection", "group": "Battery Monitoring", "field": "battery_status", "display": "Battery Status {{suffix}}", "enums": ""}, {"type": "leakDetection", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "leakDetection", "group": "Panel Temperature Monitoring", "field": "controller_temperature_sensor", "display": "Panel Temp", "enums": ""}, {"type": "leakDetection", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_percentage_sensor", "display": "Valve {{suffix}} Percent", "enums": ""}, {"type": "leakDetection", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "leakDetection", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_command", "display": "Valve Cmd", "enums": ""}, {"type": "leakDetection", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "lighting", "group": "Fault Labels - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "lighting", "group": "Light Intensity Control - Light Intensity Control", "field": "brightness_percentage_sensor", "display": "Light Intensity {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Light Intensity Control - Light Intensity Control", "field": "illuminance_sensor", "display": "Illuminance {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit", "field": "building_command", "display": "Master Lighting Cmd", "enums": "On, Off"}, {"type": "lighting", "group": "Lighting Unit", "field": "building_status", "display": "Master Lighting Status", "enums": "On, Off"}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - Lighting Control", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - RBG Scene Control", "field": "scene_command", "display": "Scene Cmd {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Lighting Unit - RBG Scene Control", "field": "scene_status", "display": "Scene Type {{suffix}}", "enums": ""}, {"type": "lighting", "group": "Occupancy Monitoring - Occupancy Monitoring", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "lighting", "group": "Occupancy Monitoring - Occupancy Monitoring", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "lighting", "group": "Panel Temperature Monitoring", "field": "controller_temperature_sensor", "display": "Panel Temp", "enums": ""}, {"type": "loopSystem", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "loopSystem", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "loopSystem", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "loopSystem", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "loopSystem", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "loopSystem", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "loopSystem", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "loopSystem", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "loopSystem", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Bypass Valve", "field": "bypass_valve_command", "display": "Bypass Valve Cmd", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Bypass Valve", "field": "bypass_valve_percentage_command", "display": "Bypass Valve Percent Cmd", "enums": ""}, {"type": "loopSystem", "group": "Bypass Valve", "field": "bypass_valve_percentage_sensor", "display": "Bypass Valve Percent", "enums": ""}, {"type": "loopSystem", "group": "Bypass Valve", "field": "bypass_valve_status", "display": "Bypass Valve Status", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "loopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "loopSystem", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "loopSystem", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "loopSystem", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "loopSystem", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "loopSystem", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "loopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "loopSystem", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "loopSystem", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "high_limit_secondary_loop_entering_temperature_setpoint", "display": "Max Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "high_limit_secondary_loop_leaving_temperature_setpoint", "display": "Max Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "low_limit_secondary_loop_entering_temperature_setpoint", "display": "Min Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "low_limit_secondary_loop_leaving_temperature_setpoint", "display": "Min Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_sensor", "display": "Sec Loop Diff Press", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_setpoint", "display": "Sec Loop Diff Press Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_differential_temperature_sensor", "display": "Sec Loop Diff Temp", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_sensor", "display": "Sec Loop Entering Temp", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_setpoint", "display": "Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_command", "display": "Sec Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_status", "display": "Sec Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_leaving_pressure_sensor", "display": "Sec Loop Leaving Press", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_sensor", "display": "Sec Loop Leaving Temp", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_setpoint", "display": "Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_pressure_sensor", "display": "Sec Loop Entering Press", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_pressure_setpoint", "display": "Sec Loop Entering Press Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_valve_command", "display": "Sec Loop Valve Cmd", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_command", "display": "Sec Loop Valve Percent Cmd", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_sensor", "display": "Sec Loop Valve Percent", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_valve_status", "display": "Sec Loop Valve Status", "enums": "Open, Close"}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_sensor", "display": "Sec Loop Water Flow", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_setpoint", "display": "Sec Loop Water Flow Setpt", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_enable_command", "display": "Sec Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_percentage_command", "display": "Sec Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_command", "display": "Sec Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "loopSystem", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_current_sensor", "display": "Sec Loop Pump {{suffix}} Current", "enums": ""}, {"type": "loopSystem", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_status", "display": "Sec Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "outdoorVRF", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "outdoorVRF", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "outdoorVRF", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "outdoorVRF", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "outdoorVRF", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "outdoorVRF", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "outdoorVRF", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "outdoorVRF", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Defrost Control", "field": "defrost_mode", "display": "Defrost Mode", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Defrost Control", "field": "defrost_status", "display": "Defrost Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "HVAC Device Control", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "outdoorVRF", "group": "HVAC Device Control", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "outdoorVRF", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "outdoorVRF", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "outdoorVRF", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "outdoorVRF", "group": "Oil Return Control", "field": "oil_return_mode", "display": "Oil Return Mode", "enums": ""}, {"type": "outdoorVRF", "group": "Oil Return Control", "field": "oil_return_status", "display": "Oil Return Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "outdoorVRF", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "compressor_discharge_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Discharge Press", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "compressor_suction_line_refrigerant_pressure_sensor", "display": "Comp {{suffix}} Suction Press", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "compressor_suction_line_temperature_sensor", "display": "Comp {{suffix}} Suction Temp", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_angularvelocity_sensor", "display": "Cond Fan {{suffix}} RPM", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_command", "display": "Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_current_sensor", "display": "Cond Fan {{suffix}} Current", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_energy_accumulator", "display": "Cond Fan {{suffix}} Total Energy", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_frequency_sensor", "display": "Cond Fan {{suffix}} Freq", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_mode", "display": "Cond Fan {{suffix}} Mode", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_power_sensor", "display": "Cond Fan {{suffix}} Power", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_run_time_accumulator", "display": "Cond Fan {{suffix}} Total Runtime", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_speed_percentage_command", "display": "Cond Fan {{suffix}} Percent Cmd", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_speed_percentage_sensor", "display": "Cond Fan {{suffix}} Percent", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_fan_status", "display": "Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_refrigerant_pressure_sensor", "display": "Cond Refrigerant Press {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "condensing_refrigerant_temperature_sensor", "display": "Cond Refrigerant Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "defrost_liquid_line_temperature_sensor", "display": "Defrost Liquid Line Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "evaporator_refrigerant_pressure_sensor", "display": "Evap Refrigerant Press {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "evaporator_refrigerant_temperature_sensor", "display": "Evap Refrigerant Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "high_condensing_fan_speed_command", "display": "High Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "high_condensing_fan_speed_status", "display": "High Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "low_condensing_fan_speed_command", "display": "Low Cond Fan {{suffix}} Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "low_condensing_fan_speed_status", "display": "Low Cond Fan {{suffix}} Status", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "low_limit_condensing_fan_speed_percentage_command", "display": "Min Cond Fan Percent Cmd", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "medium_condensing_fan_speed_command", "display": "Med Cond Fan {{suffix}} Cmd", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "medium_condensing_fan_speed_status", "display": "Med Cond Fan {{suffix}} Status", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "primary_heat_exchange_gas_line_temperature_sensor", "display": "Pri HX Gas Line Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "primary_heat_exchange_liquid_line_temperature_sensor", "display": "Pri HX Liquid Line Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "secondary_heat_exchange_gas_line_temperature_sensor", "display": "Sec HX Gas Line Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "secondary_heat_exchange_liquid_line_temperature_sensor", "display": "Sec HX Liquid Line Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "subcooling_entering_temperature_sensor", "display": "Subcool Entering Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "subcooling_expansion_valve_percentage_sensor", "display": "Subcool Expansion Valve Percent {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "subcooling_leaving_temperature_sensor", "display": "Subcool Leaving Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules", "field": "suction_line_temperature_sensor", "display": "Suction Temp {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Hot Gas Line Temperature Monitoring", "field": "inverter_compressor_hot_gas_line_temperature_sensor", "display": "Variable Comp {{suffix}} Hot Gas Line Temp {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_angularvelocity_sensor", "display": "Variable Comp {{suffix}} RPM {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_frequency_sensor", "display": "Variable Comp {{suffix}} Freq {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_run_command", "display": "Variable Comp {{suffix}} Cmd {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_run_status", "display": "Variable Comp {{suffix}} Status {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_command", "display": "Variable Comp {{suffix}} Percent Cmd {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Compressor Loop", "field": "inverter_compressor_speed_percentage_sensor", "display": "Variable Comp {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Inverter Expansion Valve Monitoring", "field": "inverter_expansion_valve_percentage_sensor", "display": "Unit Expansion Valve {{suffix}} Percent {{prefix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outdoor Modules - Outdoor Modules - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "outdoorVRF", "group": "Outside Temperature Monitoring", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "outdoorVRF", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "outdoorVRF", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "pdu", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "pdu", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "pdu", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "pdu", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "pdu", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "pdu", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "pdu", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pdu", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pdu", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pdu", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "pdu", "group": "Electrical Energy Monitoring", "field": "total_electric_energy_accumulator", "display": "Total Energy", "enums": ""}, {"type": "pdu", "group": "Electrical Energy Monitoring", "field": "total_reactive_electric_energy_accumulator", "display": "Total Reactive Energy", "enums": ""}, {"type": "pdu", "group": "Electrical Energy Monitoring - Differential Electrical Energy Monitoring", "field": "differential_electric_energy_accumulator", "display": "Total Diff Energy {{suffix}}", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_apparent_power_sensor", "display": "Apparent Power Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_average_line_current_sensor", "display": "Current Average Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_average_line_line_voltage_sensor", "display": "Voltage Line-Line Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_average_line_neutral_voltage_sensor", "display": "Voltage L-N Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_frequency_sensor", "display": "Freq Sensor Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_apparent_power_sensor", "display": "Apparent Power Phase A Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_line_current_sensor", "display": "Current Phase A Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_power_sensor", "display": "Real Power Phase A Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase1_powerfactor_sensor", "display": "Power Factor Phase A Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_apparent_power_sensor", "display": "Apparent Power Phase B Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_line_current_sensor", "display": "Current Phase B Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_power_sensor", "display": "Real Power Phase B Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase2_powerfactor_sensor", "display": "Power Factor Phase B Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_apparent_power_sensor", "display": "Apparent Power Phase C Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_line_current_sensor", "display": "Current Phase C Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_power_sensor", "display": "Real Power Phase C Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_phase3_powerfactor_sensor", "display": "Power Factor Phase C Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_power_sensor", "display": "Real Power Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_powerfactor_sensor", "display": "Power Factor Input", "enums": ""}, {"type": "pdu", "group": "Input Line", "field": "input_reactive_power_sensor", "display": "Reactive Power Input", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "pdu", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "pdu", "group": "Peak Demand Monitoring", "field": "average_power_sensor", "display": "Averaged Power", "enums": ""}, {"type": "pdu", "group": "Peak Demand Monitoring", "field": "max_power_sensor", "display": "Peak Demand", "enums": ""}, {"type": "pdu", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "pdu", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "presenceDetection", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "presenceDetection", "group": "Occupancy Count", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "max_unoccupied_count", "display": "Max Availability", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "occupancy_label", "display": "Occupany Type {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "occupancy_time_accumulator", "display": "Occupancy Duration {{suffix}}", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "ongoing_status", "display": "Domain Status", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "threshold_alarm", "display": "Limit Violation {{suffix}}", "enums": "Normal, Alarm"}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "threshold_people_capacity", "display": "Max People Number", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "threshold_percentage_command", "display": "Low Limit {{suffix}}", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "threshold_time_command", "display": "Limit Duration {{suffix}}", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring", "field": "total_unoccupied_count", "display": "Total Availability", "enums": ""}, {"type": "presenceDetection", "group": "Space Presence Monitoring - Space Presence Monitoring - Availability Count By Type", "field": "unoccupied_count", "display": "Type Availability", "enums": ""}, {"type": "pump", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "pump", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "pump", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "pump", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "pump", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "pump", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "pump", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pump", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pump", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "pump", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "pump", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "pump", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "pump", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "pump", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "pump", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "pump", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "pump", "group": "Pressure Monitoring", "field": "differential_water_pressure_sensor", "display": "Diff Water Press", "enums": ""}, {"type": "pump", "group": "Pressure Monitoring", "field": "differential_water_pressure_setpoint", "display": "Diff Water Press Setpt", "enums": ""}, {"type": "pump", "group": "Pressure Monitoring", "field": "entering_water_pressure_sensor", "display": "Entering Water Press", "enums": ""}, {"type": "pump", "group": "Pressure Monitoring", "field": "leaving_water_pressure_sensor", "display": "Leaving Water Press", "enums": ""}, {"type": "pump", "group": "Pressure Monitoring", "field": "leaving_water_pressure_setpoint", "display": "Leaving Water Press Setpt", "enums": ""}, {"type": "pump", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_command", "display": "RPM Cmd {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Angular Velocity Control", "field": "run_angularvelocity_sensor", "display": "RPM {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "pump", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "pump", "group": "Run Frequency Control", "field": "run_frequency_command", "display": "Run Freq Cmd {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Frequency Control", "field": "run_frequency_sensor", "display": "Run Freq {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "pump", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "pump", "group": "VFD Bypass Monitoring", "field": "vfd_bypass_status", "display": "VFD Bypass", "enums": "On, Off"}, {"type": "sanitation", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "sanitation", "group": "Dispenser", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "sanitation", "group": "Dispenser", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser", "field": "entering_counter", "display": "Ongoing People Counter", "enums": ""}, {"type": "sanitation", "group": "Dispenser", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "sanitation", "group": "Dispenser", "field": "supply_percentage_sensor", "display": "Percent Remaining", "enums": ""}, {"type": "sanitation", "group": "Dispenser", "field": "threshold_alarm", "display": "Limit Violation {{suffix}}", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser", "field": "threshold_people_capacity", "display": "Max People Number", "enums": ""}, {"type": "sanitation", "group": "Dispenser", "field": "threshold_percentage_command", "display": "Low Limit {{suffix}}", "enums": ""}, {"type": "sanitation", "group": "Dispenser", "field": "threshold_time_command", "display": "Limit Duration {{suffix}}", "enums": ""}, {"type": "sanitation", "group": "Dispenser - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "sanitation", "group": "Dispenser - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "sanitation", "group": "Dispenser - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "sanitation", "group": "Dispenser - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "battery_fault_status", "display": "Battery Fault Sensor", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "battery_status", "display": "Battery Status {{suffix}}", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "previous_discharge_tank_percentage_sensor", "display": "Container {{suffix}} Offload Percent", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "previous_supply_tank_percentage_sensor", "display": "Dispenser {{suffix}} Refill Percent", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "previous_tank_discharge_timestamp", "display": "Container {{suffix}} Latest Offload", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "previous_tank_supply_timestamp", "display": "Dispenser {{suffix}} Latest Refill", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component", "field": "tank_percentage_sensor", "display": "Dispenser {{suffix}} Percent", "enums": ""}, {"type": "sanitation", "group": "Dispenser Component - Dispenser Component - Container Material Count", "field": "ongoing_object_counter", "display": "Object Counter", "enums": ""}, {"type": "secLoopSystem", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "secLoopSystem", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "secLoopSystem", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "secLoopSystem", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "secLoopSystem", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "secLoopSystem", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "secLoopSystem", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "secLoopSystem", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "secLoopSystem", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "secLoopSystem", "group": "Bypass Valve", "field": "bypass_valve_command", "display": "Bypass Valve Cmd", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Bypass Valve", "field": "bypass_valve_percentage_command", "display": "Bypass Valve Percent Cmd", "enums": ""}, {"type": "secLoopSystem", "group": "Bypass Valve", "field": "bypass_valve_percentage_sensor", "display": "Bypass Valve Percent", "enums": ""}, {"type": "secLoopSystem", "group": "Bypass Valve", "field": "bypass_valve_status", "display": "Bypass Valve Status", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "secLoopSystem", "group": "Circulation Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "secLoopSystem", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "secLoopSystem", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "secLoopSystem", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "smartLocker", "group": "Group of Units - Group of Units - Subgroup of units", "field": "blocked_status", "display": "Blocked", "enums": ""}, {"type": "smartLocker", "group": "Group of Units - Group of Units - Subgroup of units", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "smartLocker", "group": "Group of Units - Group of Units - Subgroup of units", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "smartLocker", "group": "Group of Units - Group of Units - Subgroup of units", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "smartLocker", "group": "Group of Units - Group of Units - Subgroup of units", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "snowMelt", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "snowMelt", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "snowMelt", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "snowMelt", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "snowMelt", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "snowMelt", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "snowMelt", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "snowMelt", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "snowMelt", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Defrost Control", "field": "defrost_mode", "display": "Defrost Mode", "enums": "On, Off"}, {"type": "snowMelt", "group": "Defrost Control", "field": "defrost_status", "display": "Defrost Status", "enums": "On, Off"}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "snowMelt", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "high_limit_primary_loop_entering_temperature_setpoint", "display": "Max Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "high_limit_primary_loop_leaving_temperature_setpoint", "display": "Max Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "leadlag_label", "display": "Leadlag Label", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "leadlag_reversing_command", "display": "Leadlag Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Primary Loop", "field": "low_limit_primary_loop_entering_temperature_setpoint", "display": "Min Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "low_limit_primary_loop_leaving_temperature_setpoint", "display": "Min Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_differential_pressure_sensor", "display": "Pri Loop Diff Press", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_differential_pressure_setpoint", "display": "Pri Loop Diff Press Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_differential_temperature_sensor", "display": "Pri Loop Diff Temp", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_entering_temperature_sensor", "display": "Pri Loop Entering Temp", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_entering_temperature_setpoint", "display": "Pri Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_isolation_valve_run_command", "display": "Pri Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_isolation_valve_run_status", "display": "Pri Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_leaving_pressure_sensor", "display": "Pri Loop Leaving Press", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_leaving_temperature_sensor", "display": "Pri Loop Leaving Temp", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_leaving_temperature_setpoint", "display": "Pri Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_pressure_sensor", "display": "Pri Loop Entering Press", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_pressure_setpoint", "display": "Pri Loop Entering Press Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_valve_command", "display": "Pri Loop Valve Cmd", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_valve_percentage_command", "display": "Pri Loop Valve Percent Cmd", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_valve_percentage_sensor", "display": "Pri Loop Valve Postion", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_valve_status", "display": "Pri Loop Valve Status", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_water_flowrate_sensor", "display": "Pri Loop Water Flow", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop", "field": "primary_loop_water_flowrate_setpoint", "display": "Pri Loop Water Flow Setpt", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_enable_command", "display": "Pri Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_percentage_command", "display": "Pri Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_command", "display": "Pri Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_current_sensor", "display": "Pri Loop Pump {{suffix}} Current", "enums": ""}, {"type": "snowMelt", "group": "Primary Loop - Primary Loop Pump Control", "field": "primary_loop_pump_run_status", "display": "Pri Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "high_limit_secondary_loop_entering_temperature_setpoint", "display": "Max Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "high_limit_secondary_loop_leaving_temperature_setpoint", "display": "Max Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "low_limit_secondary_loop_entering_temperature_setpoint", "display": "Min Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "low_limit_secondary_loop_leaving_temperature_setpoint", "display": "Min Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_sensor", "display": "Sec Loop Diff Press", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_differential_pressure_setpoint", "display": "Sec Loop Diff Press Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_differential_temperature_sensor", "display": "Sec Loop Diff Temp", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_sensor", "display": "Sec Loop Entering Temp", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_entering_temperature_setpoint", "display": "Sec Loop Entering Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_command", "display": "Sec Loop Iso Valve Cmd", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_isolation_valve_run_status", "display": "Sec Loop Iso Valve Status", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_leaving_pressure_sensor", "display": "Sec Loop Leaving Press", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_sensor", "display": "Sec Loop Leaving Temp", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_leaving_temperature_setpoint", "display": "Sec Loop Leaving Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_pressure_sensor", "display": "Sec Loop Entering Press", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_pressure_setpoint", "display": "Sec Loop Entering Press Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_valve_command", "display": "Sec Loop Valve Cmd", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_command", "display": "Sec Loop Valve Percent Cmd", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_valve_percentage_sensor", "display": "Sec Loop Valve Percent", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_valve_status", "display": "Sec Loop Valve Status", "enums": "Open, Close"}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_sensor", "display": "Sec Loop Water Flow", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop", "field": "secondary_loop_water_flowrate_setpoint", "display": "Sec Loop Water Flow Setpt", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_enable_command", "display": "Sec Loop Pump {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_percentage_command", "display": "Sec Loop Pump {{suffix}} Percent Cmd", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_command", "display": "Sec Loop Pump {{suffix}} Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_current_sensor", "display": "Sec Loop Pump {{suffix}} Current", "enums": ""}, {"type": "snowMelt", "group": "Secondary Loop - Secondary Loop Pump Control", "field": "secondary_loop_pump_run_status", "display": "Sec Loop Pump {{suffix}} Status", "enums": "On, Off"}, {"type": "snowMelt", "group": "Slab", "field": "defrost_temperature_setpoint", "display": "Defrost Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Slab", "field": "idle_enable_status", "display": "Idle Enabled", "enums": "On, Off"}, {"type": "snowMelt", "group": "Slab", "field": "idle_temperature_setpoint", "display": "Idle Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Slab", "field": "min_slab_temperature_sensor", "display": "Min Slab Temp", "enums": ""}, {"type": "snowMelt", "group": "Slab", "field": "min_slab_temperature_setpoint", "display": "Min Slab Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Slab", "field": "storm_enable_status", "display": "Storm Enabled", "enums": "On, Off"}, {"type": "snowMelt", "group": "Slab", "field": "storm_temperature_setpoint", "display": "Storm Temp Setpt", "enums": ""}, {"type": "snowMelt", "group": "Slab - Multi Slab Temperature Control", "field": "slab_temperature_sensor", "display": "Slab {{suffix}} Temp", "enums": ""}, {"type": "snowMelt", "group": "Slab - Multi Slab Temperature Control", "field": "slab_water_detection_status", "display": "Slab Water Detection", "enums": ""}, {"type": "snowMelt", "group": "Snow Melt Mode Control", "field": "cold_season_release_status", "display": "Cold Season Released", "enums": "On, Off"}, {"type": "snowMelt", "group": "Snow Melt Mode Control", "field": "hot_season_release_status", "display": "Hot Season Released", "enums": "On, Off"}, {"type": "snowMelt", "group": "Staged Heating Control - Staged Heating Control", "field": "heating_stage_command", "display": "Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "snowMelt", "group": "Staged Heating Control - Staged Heating Control", "field": "heating_stage_status", "display": "Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "soilMonitoring", "group": "Battery Monitoring", "field": "battery_fault_status", "display": "Battery Fault Sensor", "enums": ""}, {"type": "soilMonitoring", "group": "Battery Monitoring", "field": "battery_status", "display": "Battery Status {{suffix}}", "enums": ""}, {"type": "soilMonitoring", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "soilMonitoring", "group": "Soil Conductivity Monitoring", "field": "minerals_concentration_sensor", "display": "Minerals", "enums": ""}, {"type": "soilMonitoring", "group": "Soil Moisture Monitoring", "field": "soil_humidity_sensor", "display": "Soil Moisture", "enums": ""}, {"type": "soilMonitoring", "group": "Soil Resistance Monitoring", "field": "soil_resistance_sensor", "display": "Soil resistivity", "enums": ""}, {"type": "soilMonitoring", "group": "Soil Temperature Monitoring", "field": "soil_temperature_sensor", "display": "Soil Temp", "enums": ""}, {"type": "solarPanel", "group": "Direct Current Voltage Monitoring", "field": "voltage_sensor", "display": "Voltage", "enums": ""}, {"type": "solarPanel", "group": "Electrical Energy Monitoring", "field": "total_electric_energy_accumulator", "display": "Total Energy", "enums": ""}, {"type": "solarPanel", "group": "Electrical Energy Monitoring", "field": "total_reactive_electric_energy_accumulator", "display": "Total Reactive Energy", "enums": ""}, {"type": "solarPanel", "group": "Electrical Energy Monitoring - Differential Electrical Energy Monitoring", "field": "differential_electric_energy_accumulator", "display": "Total Diff Energy {{suffix}}", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "solarPanel", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "steamMeter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "steamMeter", "group": "Mass Flow Monitoring - Mass Flow Monitoring", "field": "differential_mass_accumulator", "display": "Diff Total Mass {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Mass Flow Monitoring - Mass Flow Monitoring", "field": "total_mass_accumulator", "display": "Total Mass {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Mass Flowrate Monitoring - Mass Flowrate Monitoring", "field": "massflowrate_sensor", "display": "Mass Flow Rate {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Steam Pressure Monitoring - Steam Pressure Monitoring", "field": "steam_pressure_sensor", "display": "Steam Press {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Steam Temperature Monitoring", "field": "steam_temperature_sensor", "display": "Steam Temp", "enums": ""}, {"type": "steamMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_cost_accumulator", "display": "Cost Accumulator", "enums": ""}, {"type": "steamMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_percentage_sensor", "display": "Differential Percentage", "enums": ""}, {"type": "steamMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_volume_accumulator", "display": "Diff Total Volume {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "total_volume_accumulator", "display": "Total Volume {{suffix}}", "enums": ""}, {"type": "steamMeter", "group": "Volumetric Flowrate Monitoring - Volumetric Flowrate Monitoring", "field": "flowrate_sensor", "display": "Flow Rate {{suffix}}", "enums": ""}, {"type": "switchGear", "group": "Electrical Energy Monitoring", "field": "total_electric_energy_accumulator", "display": "Total Energy", "enums": ""}, {"type": "switchGear", "group": "Electrical Energy Monitoring", "field": "total_reactive_electric_energy_accumulator", "display": "Total Reactive Energy", "enums": ""}, {"type": "switchGear", "group": "Electrical Energy Monitoring - Differential Electrical Energy Monitoring", "field": "differential_electric_energy_accumulator", "display": "Total Diff Energy {{suffix}}", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "switchGear", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "thermohygrometer", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "thermohygrometer", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "thermohygrometer", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "thermohygrometer", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "thermohygrometer", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "thermohygrometer", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "thermohygrometer", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "thermohygrometer", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "thermohygrometer", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "thermohygrometer", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Humidity, Temperature Monitoring - Humidity, Temperature Monitoring", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "thermohygrometer", "group": "Window Status - Window Status", "field": "window_status", "display": "Window {{suffix}} Status", "enums": ""}, {"type": "trafficCounter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "trafficCounter", "group": "Entrance Counter - Entrance Counter", "field": "people_entering_counter", "display": "People IN {{suffix}}", "enums": ""}, {"type": "trafficCounter", "group": "Entrance Counter - Entrance Counter", "field": "people_leaving_counter", "display": "People OUT {{suffix}}", "enums": ""}, {"type": "uh", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "uh", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "uh", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "uh", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "uh", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "uh", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "uh", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "uh", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "uh", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "uh", "group": "Device Control or Status", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "uh", "group": "Device Control or Status", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "uh", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "uh", "group": "Electric Heat Controls - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "uh", "group": "Electric Heat Controls - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "uh", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Electric Heat Controls - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "uh", "group": "Gas Heat Controls - Gas Valve Percentage Control", "field": "gas_heater_percentage_command", "display": "Gas Valve {{suffix}} Percent Cmd", "enums": ""}, {"type": "uh", "group": "Gas Heat Controls - Gas Valve Percentage Monitoring", "field": "gas_heater_percentage_sensor", "display": "Gas Valve {{suffix}} Percent", "enums": ""}, {"type": "uh", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_command", "display": "Gas Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Gas Heat Controls - Staged Gas Heating Control", "field": "gas_heater_stage_enable_command", "display": "Gas Heat Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Gas Heat Controls - Staged Gas Heating Monitoring", "field": "gas_heater_stage_status", "display": "Gas Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_closed_command", "display": "Valve Closed Cmd", "enums": ""}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_command", "display": "Hot Water Valve Cmd", "enums": "Open, Close"}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_open_command", "display": "Valve Open Cmd", "enums": ""}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_command", "display": "Hot Water Valve Percent Cmd", "enums": ""}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_sensor", "display": "Hot Water Valve Percent", "enums": ""}, {"type": "uh", "group": "Hot Water Valve", "field": "hot_water_valve_status", "display": "Hot Water Valve Status", "enums": "Open, Close"}, {"type": "uh", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "uh", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "uh", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "uh", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "uh", "group": "Outside Temperature Control", "field": "high_limit_outside_air_temperature_enable_setpoint", "display": "Max Outside Air Temp Setpt", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "low_limit_outside_air_temperature_enable_setpoint", "display": "Min Outside Air Temp Setpt", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_humidity_sensor", "display": "Outside Air Humid", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_pressure_sensor", "display": "Outside Air Pressure", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_specificenthalpy_sensor", "display": "Outside Air Enthalpy", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_temperature_dewpoint_sensor", "display": "Outside Air Dewpoint", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_temperature_enable_setpoint", "display": "Outside Air Temp Setpt", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_temperature_sensor", "display": "Outside Air Temp", "enums": ""}, {"type": "uh", "group": "Outside Temperature Control", "field": "outside_air_temperature_wetbulb_sensor", "display": "Outside Air Wetbulb", "enums": ""}, {"type": "uh", "group": "Radiator", "field": "heating_current_sensor", "display": "Heat Current", "enums": ""}, {"type": "uh", "group": "Radiator", "field": "heating_enable_command", "display": "Heat Enable Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Radiator", "field": "heating_enable_status", "display": "Heat Enable", "enums": "On, Off"}, {"type": "uh", "group": "Radiator", "field": "radiator_temperature_sensor", "display": "Radiator Temp", "enums": ""}, {"type": "uh", "group": "Radiator - Staged Heating Control", "field": "heating_stage_command", "display": "Heat Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "uh", "group": "Radiator - Staged Heating Control", "field": "heating_stage_status", "display": "Heat Stage {{suffix}} Status", "enums": "On, Off"}, {"type": "uh", "group": "Zone Temperature Controls", "field": "building_air_temperature_setpoint", "display": "Network Zone Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "device_control_mode", "display": "Setpt Mode", "enums": "Remote, No Remote"}, {"type": "uh", "group": "Zone Temperature Controls", "field": "effective_cooling_zone_air_temperature_setpoint", "display": "Eff Cooling Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "effective_heating_zone_air_temperature_setpoint", "display": "Eff Heating Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "effective_zone_air_temperature_setpoint", "display": "Eff Zone Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "occupied_cooling_zone_air_temperature_setpoint", "display": "Occ Cooling Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "occupied_heating_zone_air_temperature_setpoint", "display": "Occ Heating Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "temperature_offset_setpoint", "display": "Zone Temp Offset", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "unoccupied_cooling_zone_air_temperature_setpoint", "display": "UnOcc Cooling Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "unoccupied_heating_zone_air_temperature_setpoint", "display": "UnOcc Heating Temp Setpt", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "uh", "group": "Zone Temperature Controls", "field": "zone_air_temperature_setpoint", "display": "Zone Temp Setpt", "enums": ""}, {"type": "ups", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "ups", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "ups", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "ups", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "ups", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "ups", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "ups", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ups", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ups", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "ups", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_average_line_current_sensor", "display": "Current Average Bypass", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_average_line_line_voltage_sensor", "display": "Voltage Line-Line Bypass", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_frequency_sensor", "display": "Freq Sensor Bypass", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B Bypass", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C Bypass", "enums": ""}, {"type": "ups", "group": "Bypass Line", "field": "bypass_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A Bypass", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_charge_current_sensor", "display": "Battery Charge Current", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_fault_status", "display": "Battery Fault Sensor", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_source_frequency_sensor", "display": "Freq Sensor Bypass Ext", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_source_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B Ext", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_source_phase1_phase3_line_voltage_sensor", "display": "Voltage C-A Ext", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_source_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C Ext", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_status", "display": "Battery Status {{suffix}}", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_temperature_sensor", "display": "Battery Temp Sensor", "enums": ""}, {"type": "ups", "group": "External Source", "field": "battery_voltage_sensor", "display": "Battery Voltage", "enums": ""}, {"type": "ups", "group": "External Source", "field": "remaining_time_sensor", "display": "Remaining Time Sensor", "enums": ""}, {"type": "ups", "group": "External Source", "field": "wheel_angularvelocity_sensor", "display": "Fly Wheel RPM", "enums": ""}, {"type": "ups", "group": "External Source", "field": "wheel_output_percentage_sensor", "display": "Fly Wheel Percent", "enums": ""}, {"type": "ups", "group": "Inlet Temperature Monitoring", "field": "air_inlet_temperature_sensor", "display": "Air Inlet Temp", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_apparent_power_sensor", "display": "Apparent Power Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_average_line_current_sensor", "display": "Current Average Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_average_line_line_voltage_sensor", "display": "Voltage Line-Line Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_average_line_neutral_voltage_sensor", "display": "Voltage L-N Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_frequency_sensor", "display": "Freq Sensor Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_apparent_power_sensor", "display": "Apparent Power Phase A Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_line_current_sensor", "display": "Current Phase A Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_power_sensor", "display": "Real Power Phase A Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase1_powerfactor_sensor", "display": "Power Factor Phase A Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_apparent_power_sensor", "display": "Apparent Power Phase B Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_line_current_sensor", "display": "Current Phase B Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_power_sensor", "display": "Real Power Phase B Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase2_powerfactor_sensor", "display": "Power Factor Phase B Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_apparent_power_sensor", "display": "Apparent Power Phase C Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_line_current_sensor", "display": "Current Phase C Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_power_sensor", "display": "Real Power Phase C Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_phase3_powerfactor_sensor", "display": "Power Factor Phase C Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_power_sensor", "display": "Real Power Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_powerfactor_sensor", "display": "Power Factor Input", "enums": ""}, {"type": "ups", "group": "Input Line", "field": "input_reactive_power_sensor", "display": "Reactive Power Input", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "max_output_current_label", "display": "Max Current Label", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "max_output_power_label", "display": "Max Power Label", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_apparent_power_sensor", "display": "Apparent Power", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_average_line_current_sensor", "display": "Current Average", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_average_line_line_voltage_sensor", "display": "Voltage Line-Line", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_average_line_neutral_voltage_sensor", "display": "Voltage Line-Neutral", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_frequency_sensor", "display": "Freq Sensor", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_ground_line_current_sensor", "display": "Current Phase G", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_line_angle_sensor", "display": "Phase Angle", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_line_compressor_offset_percentage_sensor", "display": "Line Comp Relative Offset", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_neutral_line_current_sensor", "display": "Current Phase N", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_parallel_power_sensor", "display": "Parallel Power Sensor", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_angle_sensor", "display": "Phase A Angle", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_apparent_power_sensor", "display": "Apparent Power Phase A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_frequency_sensor", "display": "Freq Phase A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_line_current_sensor", "display": "Current Phase A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_line_percentage_sensor", "display": "Phase A Line Relative Output", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_neutral_line_voltage_sensor", "display": "Voltage A-N", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_phase2_line_voltage_sensor", "display": "Voltage A-B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_power_sensor", "display": "Real Power Phase A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase1_powerfactor_sensor", "display": "Power Factor Phase A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_angle_sensor", "display": "Phase B Angle", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_apparent_power_sensor", "display": "Apparent Power Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_line_current_sensor", "display": "Current Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_line_percentage_sensor", "display": "Phase B Line Relative Output", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_neutral_line_voltage_sensor", "display": "Voltage B-N", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_phase3_line_voltage_sensor", "display": "Voltage B-C", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_power_sensor", "display": "Real Power Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase2_powerfactor_sensor", "display": "Power Factor Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_angle_sensor", "display": "Phase C Angle", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_apparent_power_sensor", "display": "Apparent Power Phase C", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_frequency_sensor", "display": "Freq Phase B", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_line_current_sensor", "display": "Current Phase C", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_line_percentage_sensor", "display": "Phase C Line Relative Output", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_neutral_line_voltage_sensor", "display": "Voltage C-N", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_phase1_line_voltage_sensor", "display": "Voltage C-A", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_power_sensor", "display": "Real Power Phase C", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_phase3_powerfactor_sensor", "display": "Power Factor Phase C", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_power_sensor", "display": "Real Power", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_powerfactor_sensor", "display": "Power Factor", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_reactive_power_sensor", "display": "Reactive Power", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_total_line_current_sensor", "display": "Total Current", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_use_percentage_sensor", "display": "Relative Output", "enums": ""}, {"type": "ups", "group": "Output Line", "field": "output_voltage_setpoint", "display": "Voltage Setpoint", "enums": ""}, {"type": "ups", "group": "Output Source", "field": "output_source_label", "display": "Output Source", "enums": ""}, {"type": "ups", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "ups", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "ups", "group": "Run Percentage Control", "field": "run_percentage_command", "display": "Run Percent Cmd {{suffix}}", "enums": ""}, {"type": "ups", "group": "Run Percentage Control", "field": "run_percentage_sensor", "display": "Run Percent {{suffix}}", "enums": ""}, {"type": "vav", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "vav", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "vav", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "vav", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "vav", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "vav", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "vav", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "vav", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "vav", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_count", "display": "Press Req", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_idle_count", "display": "Air Ignored Requests", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "air_request_multiplier_count", "display": "Press Req Multiplier", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_count", "display": "Cooling Req", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_idle_count", "display": "Cooling Ignored Requests", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "cooling_request_multiplier_count", "display": "Cooling Req Multiplier", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_count", "display": "Heating Req", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_idle_count", "display": "Heating Ignored Requests", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "heating_request_multiplier_count", "display": "Heating Req Multiplier", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "high_limit_cooling_air_temperature_setpoint", "display": "Max Cooling Upd Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "high_limit_heating_air_temperature_setpoint", "display": "Max Heating Upd Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "low_limit_cooling_air_temperature_setpoint", "display": "Min Cooling Upd Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "low_limit_heating_air_temperature_setpoint", "display": "Min Heating Upd Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "max_cooling_request_air_temperature_setpoint", "display": "Max Cooling Req Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "max_heating_request_air_temperature_setpoint", "display": "Max Heating Req Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "max_request_damper_percentage_command", "display": "Max Press Req Damper Cmd", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "min_cooling_request_air_temperature_setpoint", "display": "Min Cooling Req Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "min_heating_request_air_temperature_setpoint", "display": "Min Heating Req Setpt", "enums": ""}, {"type": "vav", "group": "Cooling, Heating, Pressure Requests", "field": "min_request_damper_percentage_command", "display": "Min Press Req Damper Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "discharge_air_pressure_sensor", "display": "Discharge Air Press", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "discharge_air_pressure_setpoint", "display": "Discharge Air Press Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "high_limit_discharge_air_pressure_setpoint", "display": "Max Discharge Press Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "low_limit_discharge_air_pressure_setpoint", "display": "Min Discharge Press Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "zone_inlet_discharge_air_pressure_sensor", "display": "Floor Supply Press", "enums": ""}, {"type": "vav", "group": "Discharge Air Pressure Control", "field": "zone_inlet_discharge_air_pressure_setpoint", "display": "Floor Supply Press Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "cold_deck_air_flowrate_sensor", "display": "Cold Deck Air Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "cold_deck_air_flowrate_setpoint", "display": "Cold Deck Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "cold_deck_air_pressure_sensor", "display": "Cold Deck Air Press", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_sensor", "display": "Discharge Air Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "discharge_air_flowrate_setpoint", "display": "Discharge Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "effective_discharge_air_flowrate_setpoint", "display": "Eff Discharge Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "hot_deck_air_flowrate_sensor", "display": "Hot Deck Air Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "hot_deck_air_flowrate_setpoint", "display": "Hot Deck Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "hot_deck_air_pressure_sensor", "display": "Hot Deck Air Press", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_discharge_air_flowrate_setpoint", "display": "Max Discharge Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_occupied_cold_air_flowrate_setpoint", "display": "Max Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Max Occ Cooling Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_occupied_heating_discharge_air_flowrate_setpoint", "display": "Max Occ Heating Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_occupied_hot_air_flowrate_setpoint", "display": "Max Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_unoccupied_cold_air_flowrate_setpoint", "display": "Max UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Max UnOcc Cooling Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Max UnOcc Heating Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "max_unoccupied_hot_air_flowrate_setpoint", "display": "Max UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_discharge_air_flowrate_setpoint", "display": "Min Discharge Air Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_occupied_cold_air_flowrate_setpoint", "display": "Min Occ Cold Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_occupied_cooling_discharge_air_flowrate_setpoint", "display": "Min Occ Cooling Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_occupied_heating_discharge_air_flowrate_setpoint", "display": "Min Occ Heating Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_occupied_hot_air_flowrate_setpoint", "display": "Min Occ Hot Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_unoccupied_cold_air_flowrate_setpoint", "display": "Min UnOcc Cold Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_unoccupied_cooling_discharge_air_flowrate_setpoint", "display": "Min UnOcc Cooling Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_unoccupied_heating_discharge_air_flowrate_setpoint", "display": "Min UnOcc Heating Flow", "enums": ""}, {"type": "vav", "group": "Discharge Airflow Control", "field": "min_unoccupied_hot_air_flowrate_setpoint", "display": "Min UnOcc Hot Deck Flow Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "balancing_damper_percentage_command", "display": "Balancing Damper Percent Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "cold_deck_damper_percentage_command", "display": "Cold Deck Damper Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "cold_deck_damper_percentage_sensor", "display": "Cold Deck Damper Status", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_closed_command", "display": "Damper Closed Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_command", "display": "Discharge Damper Cmd", "enums": "Open, Close"}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_open_command", "display": "Damper Open Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_percentage_command", "display": "Discharge Damper Percent Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_percentage_sensor", "display": "Discharge Damper Percent", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "discharge_damper_status", "display": "Discharge Damper Status", "enums": "Open, Close"}, {"type": "vav", "group": "Discharge Damper", "field": "floor_damper_command", "display": "Floor Damper Cmd", "enums": "Open, Close"}, {"type": "vav", "group": "Discharge Damper", "field": "floor_damper_status", "display": "Floor Damper Status", "enums": "Open, Close"}, {"type": "vav", "group": "Discharge Damper", "field": "hot_deck_damper_percentage_command", "display": "Hot Deck Damper Percent Cmd", "enums": ""}, {"type": "vav", "group": "Discharge Damper", "field": "hot_deck_damper_percentage_sensor", "display": "Hot Deck Damper Percent", "enums": ""}, {"type": "vav", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_dewpoint_sensor", "display": "Discharge Air Dewpoint", "enums": ""}, {"type": "vav", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_sensor", "display": "Discharge Air Temp", "enums": ""}, {"type": "vav", "group": "Discharge Temperature Control", "field": "discharge_air_temperature_setpoint", "display": "Discharge Air Temp Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Temperature Control", "field": "high_limit_discharge_air_temperature_setpoint", "display": "Max Discharge Temp Setpt", "enums": ""}, {"type": "vav", "group": "Discharge Temperature Control", "field": "low_limit_discharge_air_temperature_setpoint", "display": "Min Discharge Temp Setpt", "enums": ""}, {"type": "vav", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_enable_command", "display": "Electric Heat {{prefix}} Enable {{suffix}} Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Electric Heat Controls - Electric Heat Percentage Control", "field": "electric_heater_percentage_command", "display": "Electric Heat {{prefix}} Percent {{suffix}} Cmd", "enums": ""}, {"type": "vav", "group": "Electric Heat Controls - Electric Heat Percentage Monitoring", "field": "electric_heater_percentage_sensor", "display": "Electric Heat {{prefix}} Percent {{suffix}}", "enums": ""}, {"type": "vav", "group": "Electric Heat Controls - Electric Heater Power Monitoring", "field": "electric_heater_power_sensor", "display": "Electric Heat {{prefix}} Power {{suffix}}", "enums": ""}, {"type": "vav", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Electric Heat Controls - Staged Electric Heating Control", "field": "electric_heater_stage_enable_command", "display": "Electric Heat {{prefix}} Stage {{suffix}} Enable Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Electric Heat Controls - Staged Electric Heating Monitoring", "field": "electric_heater_stage_status", "display": "Electric Heat {{prefix}} Stage {{suffix}}", "enums": "On, Off"}, {"type": "vav", "group": "Enable Control", "field": "enable_command", "display": "Enable Cmd {{suffix}}", "enums": "On, Off"}, {"type": "vav", "group": "Enable Control", "field": "enable_status", "display": "Enabled Status {{suffix}}", "enums": "On, Off"}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_closed_command", "display": "Valve Closed Cmd", "enums": ""}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_command", "display": "Hot Water Valve Cmd", "enums": "Open, Close"}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_open_command", "display": "Valve Open Cmd", "enums": ""}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_command", "display": "Hot Water Valve Percent Cmd", "enums": ""}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_percentage_sensor", "display": "Hot Water Valve Percent", "enums": ""}, {"type": "vav", "group": "Hot Water Valve", "field": "hot_water_valve_status", "display": "Hot Water Valve Status", "enums": "Open, Close"}, {"type": "vav", "group": "Network Thermostat", "field": "building_air_temperature_setpoint", "display": "Network Zone Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "device_control_mode", "display": "Setpt Mode", "enums": "Remote, No Remote"}, {"type": "vav", "group": "Network Thermostat", "field": "device_mode", "display": "Device Mode", "enums": "Cooling, Heating"}, {"type": "vav", "group": "Network Thermostat", "field": "device_status", "display": "Device Status", "enums": "Cooling, Heating"}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_angularvelocity_sensor", "display": "Discharge Fan RPM", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_command", "display": "Discharge Fan Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_current_sensor", "display": "Discharge Fan Current", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_enable_command", "display": "Discharge Fan Enable Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_enable_status", "display": "Discharge Fan Enabled", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_energy_accumulator", "display": "Discharge Fan Total Energy", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_frequency_sensor", "display": "Discharge Fan Freq", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_mode", "display": "Discharge Fan Mode", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_power_sensor", "display": "Discharge Fan Power", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_run_time_accumulator", "display": "Discharge Fan Total Runtime", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_speed_percentage_command", "display": "Discharge Fan Percent Cmd", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_speed_percentage_sensor", "display": "Discharge Fan Percent", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "discharge_fan_status", "display": "Discharge Fan Status", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "effective_cooling_zone_air_temperature_setpoint", "display": "Eff Cooling Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "effective_heating_zone_air_temperature_setpoint", "display": "Eff Heating Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "effective_zone_air_temperature_setpoint", "display": "Eff Zone Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "high_discharge_fan_speed_command", "display": "High Discharge Fan Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "high_discharge_fan_speed_status", "display": "High Discharge Fan Status", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "low_discharge_fan_speed_command", "display": "Low Discharge Fan Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "low_discharge_fan_speed_status", "display": "Low Discharge Fan Status", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "low_limit_discharge_fan_speed_percentage_command", "display": "Min Discharge Fan Percent Cmd", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "medium_discharge_fan_speed_command", "display": "Med Discharge Fan Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Network Thermostat", "field": "medium_discharge_fan_speed_status", "display": "Med Discharge Fan Status", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "occupied_cooling_zone_air_temperature_setpoint", "display": "Occ Cooling Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "occupied_heating_zone_air_temperature_setpoint", "display": "Occ Heating Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "temperature_offset_setpoint", "display": "Zone Temp Offset", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "unoccupied_cooling_zone_air_temperature_setpoint", "display": "UnOcc Cooling Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "unoccupied_heating_zone_air_temperature_setpoint", "display": "UnOcc Heating Temp Setpt", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "zone_air_temperature_dewpoint_sensor", "display": "Zone Dewpoint {{suffix}}", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "zone_air_temperature_sensor", "display": "Zone Temp {{suffix}}", "enums": ""}, {"type": "vav", "group": "Network Thermostat", "field": "zone_air_temperature_setpoint", "display": "Zone Temp Setpt", "enums": ""}, {"type": "vav", "group": "Occupancy Control", "field": "motion_detection_sensor", "display": "Motion Detection {{suffix}}", "enums": "Active, Idle"}, {"type": "vav", "group": "Occupancy Control", "field": "occupancy_count", "display": "Presence Counter {{suffix}}", "enums": ""}, {"type": "vav", "group": "Occupancy Control", "field": "occupancy_status", "display": "Eff Occupancy {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "vav", "group": "Occupancy Control", "field": "occupied_mode", "display": "Occupancy Cmd {{suffix}}", "enums": "Occupied, Unoccupied"}, {"type": "vav", "group": "Particle Monitoring - PM1 Level Control", "field": "high_limit_pm1_concentration_setpoint", "display": "Max PM1 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM1 Level Control", "field": "low_limit_pm1_concentration_setpoint", "display": "Min PM1 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM1 Level Control", "field": "pm1_concentration_detection_sensor", "display": "PM1 {{suffix}}", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM10 Level Control", "field": "high_limit_pm10_concentration_setpoint", "display": "Max PM10 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM10 Level Control", "field": "low_limit_pm10_concentration_setpoint", "display": "Min PM10 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM10 Level Control", "field": "pm10_concentration_detection_sensor", "display": "PM10 {{suffix}}", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM25 Level Control", "field": "high_limit_pm25_concentration_setpoint", "display": "Max PM25 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM25 Level Control", "field": "low_limit_pm25_concentration_setpoint", "display": "Min PM25 {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - PM25 Level Control", "field": "pm25_concentration_detection_sensor", "display": "PM25 {{suffix}}", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - TVOC Level Control", "field": "high_limit_voc_concentration_setpoint", "display": "Max VOC {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - TVOC Level Control", "field": "low_limit_voc_concentration_setpoint", "display": "Min VOC {{suffix}} Setpt", "enums": ""}, {"type": "vav", "group": "Particle Monitoring - TVOC Level Control", "field": "voc_concentration_detection_sensor", "display": "VOC {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Control", "field": "run_command", "display": "Run Cmd {{suffix}}", "enums": "On, Off"}, {"type": "vav", "group": "Run Control", "field": "run_status", "display": "Run Status {{suffix}}", "enums": "On, Off"}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "run_current_sensor", "display": "Current {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "run_energy_accumulator", "display": "Total Energy {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "run_power_sensor", "display": "Power {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "run_time_accumulator", "display": "Total Runtime {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "run_voltage_sensor", "display": "Voltage {{suffix}}", "enums": ""}, {"type": "vav", "group": "Run Statistics Monitoring", "field": "start_counter", "display": "Total Starts {{suffix}}", "enums": ""}, {"type": "vav", "group": "Supplemental Heat Control", "field": "supplemental_heater_command", "display": "Sup Heat Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Supplemental Heat Control", "field": "supplemental_heater_enable_command", "display": "Sup Heat Enable Cmd", "enums": "On, Off"}, {"type": "vav", "group": "Supplemental Heat Control", "field": "supplemental_heater_percentage_command", "display": "Sup Heat Percent Cmd", "enums": ""}, {"type": "vav", "group": "Supplemental Heat Control", "field": "supplemental_heater_percentage_sensor", "display": "Sup Heat Percent", "enums": ""}, {"type": "vav", "group": "Supply Temperature Control", "field": "supply_air_temperature_sensor", "display": "Supply Air Temp", "enums": ""}, {"type": "vav", "group": "Supply Temperature Control", "field": "supply_air_temperature_setpoint", "display": "Supply Air Temp Setpt", "enums": ""}, {"type": "vav", "group": "Unoccupied HVAC Device Control", "field": "unoccupied_device_mode", "display": "UnOcc Device Mode", "enums": ""}, {"type": "vav", "group": "Unoccupied HVAC Device Control", "field": "unoccupied_device_status", "display": "UnOcc Device Status", "enums": "Cooling, Heating"}, {"type": "vav", "group": "Window Status - Window Status", "field": "window_status", "display": "Window {{suffix}} Status", "enums": ""}, {"type": "vav", "group": "Zone Air Pressure Control", "field": "zone_air_static_pressure_sensor", "display": "Zone Static Press", "enums": ""}, {"type": "vav", "group": "Zone Air Pressure Control", "field": "zone_air_static_pressure_setpoint", "display": "Zone Static Press Setpt", "enums": ""}, {"type": "vav", "group": "Zone CO2 Control", "field": "high_limit_zone_air_co2_concentration_setpoint", "display": "Max Zone CO2 Setpt", "enums": ""}, {"type": "vav", "group": "Zone CO2 Control", "field": "low_limit_zone_air_co2_concentration_setpoint", "display": "Min Zone CO2 Setpt", "enums": ""}, {"type": "vav", "group": "Zone CO2 Control", "field": "min_ventilation_deadband_co2_concentration_setpoint", "display": "Min Ventillation C02 Setpt", "enums": ""}, {"type": "vav", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_sensor", "display": "Zone CO2", "enums": ""}, {"type": "vav", "group": "Zone CO2 Control", "field": "zone_air_co2_concentration_setpoint", "display": "Zone CO2 Setpt", "enums": ""}, {"type": "vav", "group": "Zone Humidity Control", "field": "high_limit_zone_air_humidity_setpoint", "display": "Max Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "vav", "group": "Zone Humidity Control", "field": "low_limit_zone_air_humidity_setpoint", "display": "Min Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "vav", "group": "Zone Humidity Control", "field": "zone_air_dehumidification_setpoint", "display": "Zone Air DeHumid Setpt {{suffix}}", "enums": ""}, {"type": "vav", "group": "Zone Humidity Control", "field": "zone_air_humidity_sensor", "display": "Zone Air Humid {{suffix}}", "enums": ""}, {"type": "vav", "group": "Zone Humidity Control", "field": "zone_air_humidity_setpoint", "display": "Zone Air Humid Setpt {{suffix}}", "enums": ""}, {"type": "wasteCollector", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "wasteCollector", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "wasteCollector", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "wasteCollector", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "wasteCollector", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "wasteCollector", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "wasteCollector", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "wasteCollector", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "wasteCollector", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "wasteCollector", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "wasteCollector", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "battery_fault_status", "display": "Battery Fault Sensor", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "battery_percentage_sensor", "display": "Battery {{suffix}} Remaining", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "battery_status", "display": "Battery Status {{suffix}}", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "previous_discharge_tank_percentage_sensor", "display": "Container {{suffix}} Offload Percent", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "previous_supply_tank_percentage_sensor", "display": "Dispenser {{suffix}} Refill Percent", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "previous_tank_discharge_timestamp", "display": "Container {{suffix}} Latest Offload", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "previous_tank_supply_timestamp", "display": "Dispenser {{suffix}} Latest Refill", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component", "field": "tank_percentage_sensor", "display": "Dispenser {{suffix}} Percent", "enums": ""}, {"type": "wasteCollector", "group": "Dispenser Component - Dispenser Component - Container Material Count", "field": "ongoing_object_counter", "display": "Object Counter", "enums": ""}, {"type": "waterMeter", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "waterMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_cost_accumulator", "display": "Cost Accumulator", "enums": ""}, {"type": "waterMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_percentage_sensor", "display": "Differential Percentage", "enums": ""}, {"type": "waterMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "differential_volume_accumulator", "display": "Diff Total Volume {{suffix}}", "enums": ""}, {"type": "waterMeter", "group": "Volumetric Flow Monitoring - Volumetric Flow Monitoring", "field": "total_volume_accumulator", "display": "Total Volume {{suffix}}", "enums": ""}, {"type": "waterMeter", "group": "Volumetric Flowrate Monitoring - Volumetric Flowrate Monitoring", "field": "flowrate_sensor", "display": "Flow Rate {{suffix}}", "enums": ""}, {"type": "waterTank", "group": "Alarms", "field": "emergency_command", "display": "Emergency Cmd", "enums": "On, Off"}, {"type": "waterTank", "group": "Alarms", "field": "emergency_status", "display": "Emergency Status", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Alarms", "field": "reset_alarm", "display": "Reset Events", "enums": ""}, {"type": "waterTank", "group": "Alarms - Fault Labels", "field": "fault_label", "display": "{{fieldsInConnector.name}}", "enums": "Normal"}, {"type": "waterTank", "group": "Alarms - Filter Alarms", "field": "filter_reset_command", "display": "Filter {{suffix}} Reset", "enums": ""}, {"type": "waterTank", "group": "Alarms - Filter Alarms", "field": "filter_status", "display": "Filter {{suffix}} Status", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Alarms - High Priority Alarms", "field": "high_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Alarms - Low Priority Alarms", "field": "low_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Alarms - Medium Priority Alarms", "field": "medium_priority_alarm", "display": "{{fieldsInConnector.name}}", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Alarms - Previous Alarm", "field": "previous_alarm", "display": "Previous Alarm {{suffix}}", "enums": ""}, {"type": "waterTank", "group": "Bypass Valve", "field": "bypass_valve_command", "display": "Bypass Valve Cmd", "enums": "Open, Close"}, {"type": "waterTank", "group": "Bypass Valve", "field": "bypass_valve_percentage_command", "display": "Bypass Valve Percent Cmd", "enums": ""}, {"type": "waterTank", "group": "Bypass Valve", "field": "bypass_valve_percentage_sensor", "display": "Bypass Valve Percent", "enums": ""}, {"type": "waterTank", "group": "Bypass Valve", "field": "bypass_valve_status", "display": "Bypass Valve Status", "enums": "Open, Close"}, {"type": "waterTank", "group": "Connection Status", "field": "connection_status", "display": "Connection Status", "enums": "Connected, Disconnected"}, {"type": "waterTank", "group": "Goods Supply Monitoring", "field": "supply_percentage_sensor", "display": "Percent Remaining", "enums": ""}, {"type": "waterTank", "group": "Operation Control", "field": "control_mode", "display": "Control Mode", "enums": ""}, {"type": "waterTank", "group": "Operation Control", "field": "control_status", "display": "Control Status", "enums": ""}, {"type": "waterTank", "group": "Pressure Monitoring", "field": "differential_water_pressure_sensor", "display": "Diff Water Press", "enums": ""}, {"type": "waterTank", "group": "Pressure Monitoring", "field": "differential_water_pressure_setpoint", "display": "Diff Water Press Setpt", "enums": ""}, {"type": "waterTank", "group": "Pressure Monitoring", "field": "entering_water_pressure_sensor", "display": "Entering Water Press", "enums": ""}, {"type": "waterTank", "group": "Pressure Monitoring", "field": "leaving_water_pressure_sensor", "display": "Leaving Water Press", "enums": ""}, {"type": "waterTank", "group": "Pressure Monitoring", "field": "leaving_water_pressure_setpoint", "display": "Leaving Water Press Setpt", "enums": ""}, {"type": "waterTank", "group": "Tank Level Monitoring - Tank Level Monitoring", "field": "threshold_alarm", "display": "Limit Violation {{suffix}}", "enums": "Normal, Alarm"}, {"type": "waterTank", "group": "Tank Level Monitoring - Tank Level Monitoring", "field": "threshold_people_capacity", "display": "Max People Number", "enums": ""}, {"type": "waterTank", "group": "Tank Level Monitoring - Tank Level Monitoring", "field": "threshold_percentage_command", "display": "Low Limit {{suffix}}", "enums": ""}, {"type": "waterTank", "group": "Tank Level Monitoring - Tank Level Monitoring", "field": "threshold_time_command", "display": "Limit Duration {{suffix}}", "enums": ""}, {"type": "waterTank", "group": "Tank Temperature Control", "field": "tank_water_temperature_sensor", "display": "Tank Water Temp", "enums": ""}, {"type": "waterTank", "group": "Tank Temperature Control", "field": "tank_water_temperature_setpoint", "display": "Tank Water Temp Setpt", "enums": ""}, {"type": "waterTank", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_percentage_sensor", "display": "Valve {{suffix}} Percent", "enums": ""}, {"type": "waterTank", "group": "Valve Monitoring - Valve Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "waterTank", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_command", "display": "Valve Cmd", "enums": ""}, {"type": "waterTank", "group": "Valve Monitoring - Valve Monitoring - Valve Position Monitoring", "field": "valve_status", "display": "Valve Status", "enums": ""}, {"type": "waterTank", "group": "Water Filter Monitoring - Water Filter Monitoring", "field": "filter_differential_water_pressure_sensor", "display": "Filter Diff Press", "enums": ""}, {"type": "waterTank", "group": "Water Filter Monitoring - Water Filter Monitoring", "field": "water_filter_alarm", "display": "Filter Alarm", "enums": ""} ] ``` # Schedules Source: https://docs.kodelabs.com/products/kode-os/schedules Automate equipment operation with time-based schedules, holiday overrides, and AI-powered Optimized Start/Stop. > [!NOTE] > > Schedules is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its schedules. Mass write is accessible at the portfolio level. Schedules automate equipment operation based on time. Define when devices should turn on and off, set temperature setpoints for occupied and unoccupied periods, and configure holiday overrides. Cloud BMS supports two schedule types: * **Weekly schedules** -- define recurring time-based events for regular building operation * **Calendar schedules** -- define exception dates for holidays and special events that can be referenced by weekly schedules ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR SCH[Schedule] -- "controls" --> DEV[Device] OSS[OSS Algorithm] -- "optimizes" --> SCH OSS -. "inputs" .- SENS[Sensor Data] OSS -. "inputs" .- WX[Weather Data] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef peach stroke:#FBB35A,fill:#FFEFDB,color:#8F632D classDef green fill:#B0E4CC,color:#285A48,stroke:#285A48 class SCH sky class DEV peach class OSS green class SENS,WX green ``` ## Navigate to schedules **1. Select your site** Click `Sites` in the left navigation bar and select the building. **2. Open the schedules module** Click `Schedules` in the left sidebar menu. The schedules list displays all configured schedules for the selected site. ![Schedules list showing three schedules with Name, Area, Current and Next Value, and Data Source columns, plus search, Weekly Schedules filter, Show Only Visible filter, Filters button, Sync button, and Create Schedule button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-list.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=0dc524db9a8dbee2ce33c70943f99935) The Schedules list shows all schedules with their current and next values, area, data source, and options to search, filter, sync, and create The schedules list displays the building's local time and shows each schedule's current value and next scheduled value with timestamp. Use the toolbar to: * **Search** for schedules by name * **Filter** by schedule type (`Weekly Schedules` or `Calendar Schedules`) and visibility * **Sync** schedules with the external building automation system * Toggle between list and calendar view using the view icons ![Schedules list with the type filter dropdown open showing Weekly Schedules selected with a checkmark and Calendar Schedules as an alternative option](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-filter-type.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=b4a907de54456077abe97376c8925e8e) The type filter dropdown lets you switch between Weekly Schedules and Calendar Schedules ### Schedule actions Click the three-dot menu on a schedule row to access schedule-level actions. ![Schedule row menu showing Duplicate Schedule, Hide Schedule, Edit Schedule, Delete from Cloud BMS, and Delete Everywhere options](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-row-menu.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=8c1c86ae944ff3edceacdd4cffa5397d) The row menu provides options to duplicate, hide, edit, or delete a schedule * **Duplicate Schedule** -- create a copy of the schedule with the same configuration * **Hide Schedule** -- hide the schedule from the list without deleting it (use `Show Only Visible` filter to toggle hidden schedules) * **Edit Schedule** -- open the schedule details page to modify its configuration * **Delete from Cloud BMS** -- remove the schedule from Cloud BMS only, keeping it in the data source * **Delete Everywhere** -- remove the schedule from both Cloud BMS and the connected data source ### Batch update Click the batch update icon in the toolbar to open the Schedules Batch Update view. ![Schedules list with the batch update icon highlighted in the toolbar showing a Schedules Batch Update tooltip](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-batch-update.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=c43981dc5ee30287dfccd6e926126662) The batch update icon in the toolbar opens the Schedules Batch Update page Select one or more schedules using the checkboxes to perform bulk actions. The batch update view shows the schedule path, area, and current and next values. Use the action bar at the bottom to delete selected schedules from Cloud BMS, delete them everywhere, or change their visibility. ![Schedules Batch Update page with Weekly Schedule and Scoda Nexus\_training selected, showing Name, Path, Area, and Current and Next Value columns, with Cancel, Delete from Cloud BMS, Delete Everywhere, and Change Visibility buttons at the bottom](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-batch-update-view.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=509b4b8c55f75982470fc6ba02a9199a) The batch update view allows selecting multiple schedules for bulk delete or visibility changes ### Calendar view Switch to the calendar view using the calendar icon in the toolbar. The calendar view displays all schedules on a weekly grid, showing event blocks with their time ranges and values. ![Calendar view showing May 2026 in week view with Weekly Schedule selected, displaying green event blocks from 8:00 AM to 4:00 PM Monday through Friday with value true, and a Friday all-day special event in orange](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-view.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=aeef1e1b701889946c133ce02db8e4cd) The calendar view displays schedule events on a weekly grid with day, week, and month views Use the sidebar on the left to select which schedules to display. Each schedule shows the number of special events configured. Toggle between `Day`, `Week`, and `Month` views using the tabs at the top, and navigate between weeks using the arrow buttons. ## Create a schedule Click `Create Schedule` to open the creation dialog. ![Create New Schedule dialog with fields for Name, Folder, Data Source dropdown, Type selection between Calendar Schedule and Weekly Schedule, and Kind dropdown showing Boolean Schedule](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-create.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=0620855a7bee192d81e50164a31141a8) The Create New Schedule dialog collects the schedule name, folder, data source, type, and kind **Name** `Field` Enter a descriptive name for the schedule (for example, `Weekly Schedule`). **Folder** `Field` Specify the folder path where the schedule is stored in the data source. **Data Source** `Field` Select the data source connector this schedule belongs to. **Type** `Field` Choose the schedule type: * **Calendar Schedule** -- for special events and holidays * **Weekly Schedule** -- for regular recurring usage **Kind** `Field` Select the schedule kind (for example, `Boolean Schedule` for on/off control). Click `Save` to create the schedule and open its details page. ## Configure schedule types After you create a schedule, configure weekly recurrence or calendar exceptions. > [tab] Weekly schedules > > Weekly schedules define recurring time-based events for regular building operation. Select `Weekly Schedule` as the type when creating a schedule. > > ### Schedule details and properties > > After creating or selecting a weekly schedule, the details page displays the schedule configuration and the weekly calendar grid. > > ![Schedule Details page for Weekly Schedule showing Schedule Name, Display Name, Data Source, Area, Kind, Location fields, Effective Period with Start and End dates, Default Value set to False, and Key/Value pairs for falseText and trueText](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-details.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=28fa9e610940573305c53d60f56bdc47) > > The Schedule Details page shows schedule properties, effective period, default value, and key/value mappings > > The `Schedule Details & Properties` panel includes: > > * **Schedule Name** -- the internal name of the schedule > * **Display Name** -- the user-facing name shown in the schedules list > * **Data Source** -- the connected data source > * **Area** -- the area this schedule applies to (optional) > * **Kind** -- the schedule kind (for example, `BooleanSchedule`) > * **Location** -- the slot path in the data source > > #### Effective period and default value > > * **Effective Start / Effective End** -- define the date range during which the schedule is active > * **Default Value** -- the fallback value when no scheduled event is active (for example, `False` for a boolean schedule). Check `Null` to use no default value. > * **Key/Value pairs** -- define the display text for schedule values (for example, `falseText` = `false`, `trueText` = `true`) > > Click `Sync` to synchronize the schedule with the external system. The last synced timestamp is displayed next to the sync button. > > > [!NOTE] > > > > Some fields and functionalities may not be available for editing because of data source capabilities. A warning banner appears at the top of the page when this applies. > > ### Configure weekly events > > The weekly calendar grid displays the schedule's time blocks for each day of the week. Click on a time slot to access event options. > > ![Weekly schedule calendar grid showing Sunday through Saturday with time slots from 12:00am to 9:00pm, and a right-click menu with Create Event, All Day Event, and Clear Week options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=e7d3924b51f004b4551f393e0bce34ec) > > Click on the weekly calendar to create events, all day events, or clear the week > > * **Create Event** -- add a time-based event for a specific day > * **All Day Event** -- create an event that spans the entire day > * **Clear Week** -- remove all events from the weekly schedule > > #### Add an event > > Select `Create Event` to open the Add Event dialog. > > ![Add Event dialog with Start Time set to 08:00 AM, End Time set to 04:00 PM, Value dropdown set to True, and a Null checkbox](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-add-event.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=994d1868bb8b00bd2a9c83b6bc9465e5) > > The Add Event dialog sets the start time, end time, value, and null option for the event > > **Start Time** `Field` > > Set the event start time. Toggle between `AM` and `PM`. > > **End Time** `Field` > > Set the event end time. Toggle between `AM` and `PM`. > > **Value** `Field` > > Select the value to write during this event (for example, `True` for on, `False` for off). > > Check `Null` to clear the value during this period instead of writing a specific value. Click `Save` to add the event to the calendar. > > #### Manage events > > Once an event is created, it appears as a colored block on the calendar. Click a created event to access management options. > > ![Weekly schedule showing a green event block on Monday from 8:00 AM to 4:00 PM with value true, and a right-click menu showing Edit Event, Delete Event, Apply M-F, Apply Everyday, and Clear Week options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-event-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=fc23e3a440d5c5e601706052ace72ec4) > > Click a created event to edit, delete, or apply it across multiple days > > * **Edit Event** -- modify the event's time window or value > * **Delete Event** -- remove the event from the calendar > * **Apply M-F** -- copy the event to all weekdays (Monday through Friday) > * **Apply Everyday** -- copy the event to every day of the week > * **Clear Week** -- remove all events from the weekly schedule > > Click `Save` at the top right to save all changes. After saving, the schedule view displays the configured weekly calendar with the activity log on the right showing the change history. > > ![Weekly Schedule view showing green event blocks from 8:00 AM to 4:00 PM on Monday through Friday with value true, History Logs and Point References links, and an activity log with user change entries](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-saved-calendar.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=dd6fdea9bfa5e36d334397297d3bfd2f) > > The saved schedule shows the weekly calendar with events applied Monday through Friday, and the activity log on the right > > The schedule header provides access to `History Logs` and `Point References`. Click `Delete Schedule` to remove the schedule entirely. > > ### Schedule history and revert > > Open `History Logs` (or the History tab on the schedule) to review prior versions. Select a timestamp, then click `Revert` to restore that version. When the connector supports it, Cloud BMS pushes the restored version back to the data source. > > ### Special events > > Special events override the weekly schedule on specific dates such as holidays, building closures, or maintenance windows. Switch to the `Special Events` tab to manage exception dates. > > ![Special Events tab showing an empty events list with Name, Type, and Value columns, and a New Event button](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-events-empty.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=2b8ed1ce55df7bf54f631fa2d407bed9) > > The Special Events tab shows a list of exception events with options to create new ones > > #### Create a special event > > Click `+ New Event` to open the Add Special Event dialog. > > ![Add Special Event dialog with Name field showing Friday off, Type dropdown set to Custom, Weekday set to Friday, Day set to 15, Week set to Any, Month set to May, and Year set to 2026](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-add-special-event.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=2bcdd7aafbaf4f3b30e89c11d75244e9) > > The Add Special Event dialog configures the event name, type, date, and recurrence > > **Name** `Field` > > Enter a descriptive name for the special event (for example, `Friday off`). > > **Type** `Field` > > Select the event type: > > * **Custom** -- define a one-off exception date manually > * **Reference** -- link to a calendar schedule so its events are inherited automatically > > **Weekday / Day / Week / Month** `Field` > > Configure the date pattern for the event. Set the specific weekday, day of the month, week, and month. > > **Year** `Field` > > Select the year for the event. Click the calendar icon to pick a date visually. > > ![Add Special Event dialog with a calendar picker showing May 2026 with the 15th highlighted](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-calendar.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=bd04397e9c7c05a29f93d52b96905814) > > The calendar picker helps select the exact date for the special event > > Click `Save` to create the event. The event appears in the Special Events list with a "Time Missing" indicator if no time-based event has been added to its day calendar. > > ![Special Events tab showing Friday off event with Custom type, Time Missing indicator, and a blank day calendar on the right with edit and delete icons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-created.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=e7648a696ba8959d95f06b42753ee1fc) > > The created special event shows in the list with a Time Missing warning and the day calendar on the right > > #### Add events to a special event day > > Click on the day calendar on the right to add time-based events for the special event day. > > ![Special event day calendar with a right-click menu showing Create Event and All Day Event options](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-day-menu.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=7469257cbf353419cdc97838c0077e48) > > Click on the special event day calendar to create an event or all day event > > After adding an event, the day calendar shows the override value for the special event day (for example, `false` for the entire day to turn equipment off). > > ![Special Events tab with Friday off event showing a pink all-day block with value false from 12:00 AM to 12:00 AM on the day calendar](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-value.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=19e1fc6065ac95770c95faaafe5faba7) > > The special event day calendar shows an all-day override with the configured value > > Expand a special event row by clicking the chevron to view its date details (Weekday, Week, Day, Month). > > ![Schedule Details page showing the Special Events tab with Friday off expanded showing Weekday Friday, Week Any, Day 15, Month May, and the day calendar with a pink false block](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-details.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=95d929c5a1089bbc50a1c554eaa8ce54) > > The expanded special event row shows the configured date pattern alongside the day calendar and Point Trends > > #### Reference events > > Reference events link a [calendar schedule](#calendar-schedules) to a weekly schedule. Instead of manually recreating the same holidays across multiple weekly schedules, you reference a single calendar schedule and all its events are inherited automatically. > > To add a reference event, click `+ New Event` and set the `Type` to `Reference`. Select the calendar schedule from the `Reference` dropdown. > > ![Add Special Event dialog with Name set to Holidays, Type set to Reference, and Reference dropdown showing a slot path to a calendar schedule](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-event-reference.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=68aee984741eb92fb4a91c9c885e94ec) > > A Reference type event links to an existing calendar schedule by its slot path > > The referenced calendar schedule's events appear in the Special Events list alongside any custom events. Changes made to the source calendar schedule (adding, editing, or removing events) are automatically reflected in every weekly schedule that references it. > > ![Special Events tab showing Friday off as Custom type and Holidays as Reference type with slot path value, day calendar on the right showing an all-day false override from 12:00 AM to 12:00 AM, plus Reorder Events Priority button](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-special-events-reference-applied.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=84a088e8e4bbf0738e4516c71dffa8ad) > > The Special Events list shows both Custom and Reference events, with the day calendar displaying the override value for the selected event > > > [!TIP] > > > > Use reference events to maintain a shared holiday calendar across multiple weekly schedules. Update the calendar schedule once and all linked weekly schedules reflect the changes automatically. > > ### Point references > > Point references link the schedule to specific device points that the schedule controls. Click `Point References` in the schedule header to view and manage the points associated with this schedule. > > ![Point References page for Weekly Schedule showing a table with Point, Device, Type, Target Slot, Kind, Area, Data Source, Source Slot, and Current Value columns, with a search bar and Filters option](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-point-references.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=c525fe3de9eab9c5705157879089da6e) > > The Point References page lists all points linked to this schedule with their device, type, and current value > > Click the edit icon to enter edit mode, then click `Add Point References` to link new points. > > ![Edit mode for Point References showing the Add Point References link, with Point, Device, Type, Target Slot, Kind, Area, Data Source, and Source Slot columns](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-point-references-edit.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=bff37ede1ebc818f4dbeb54b2f4dc02a) > > Edit mode for Point References shows the Add Point References option > > #### Add point references > > Click `Add Point References` to open the Apply Point References dialog. The process has two steps: > > **Step 1: Choose filters** -- narrow down the available points by Data Sources, Area, Device Type, Kind, and Field. > > ![Apply Point References dialog showing step 1 Choose Filters with Data Sources filter showing TR Fisnik with 220 points, Area filter with Floor 2, Floor 3, and Not Assigned options, and Device Type filter with Loop System, FCU, AHU, VAV, and Not Assigned options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-apply-filters.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=1e1a4d90c226a3b0e82836171dc1c8ae) > > Step 1 filters points by data source, area, and device type > > ![Apply Point References dialog showing Device Type, Kind filter with Bool selected showing 50 points, and Field filter with occ search showing occupancy\_status and occupied\_mode options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-apply-filters-kind.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=ac8246feee23416720bf39724a267e3d) > > Additional filters for Kind and Field help narrow down the exact points to reference > > **Step 2: Choose points** -- select the individual points from the filtered list. > > ![Apply Point References step 2 showing 38 selected Occupancy Cmd points of kind Bool from TR Fisnik data source across VAV\_101 through VAV\_109 devices, with an Apply Point Reference button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-choose-points.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=535067733c006a3407379ba1c1b86055) > > Step 2 displays the filtered points for selection with their kind, data source, and device > > Select the points you want to link to the schedule and click `Apply Point Reference`. > > After applying, the point references list shows all linked points with their type, target slot, kind, and area. > > When you schedule writable points, confirm the Target slot (The command priority slot where the schedule writes values on the point. The default is often in10, but integrations can differ.) before you mass-apply references. The default is often `in10`, but the correct slot can vary by integration. Confirm your deployment standard first. > > Importing a discovered schedule does not create missing points. If a schedule references points that do not exist in Cloud BMS, those references stay unresolved until you discover and add the points. > > ![Point References edit mode showing 38 Occupancy Cmd points with Direct type, in10 target slot, Bool kind, and areas including Floor 2 and Floor 3, with delete icons on each row](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-point-references-applied.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=38846ea41582bbc7d9ab261a709be1c5) > > The applied point references show Occupancy Cmd points linked to VAV devices with Direct type and in10 target slot > > #### Reference types > > Each point reference has a `Type` that determines how the schedule controls the point. Click the Type dropdown to change the reference type. > > ![Type dropdown showing Direct option selected with description that the point reference will be synced with the data source, and Indirect option with description that the relation remains in Cloud BMS but is not synced](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-point-references-type.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=5ad67bfe120236ecbfe04aac01451027) > > The Type dropdown provides Direct and Indirect reference options with descriptions > > * **Direct (Synced with the data source so the schedule can control the point when the connector supports it.)** -- the point reference is synced with the data source. If successful, the schedule controls the device directly. Direct references are available only when the point can be controlled by Cloud BMS directly. > * **Indirect (Stored in Cloud BMS only. Tracks the relationship without syncing control to the data source.)** -- the relation is stored in Cloud BMS but is not synced with the data source. Use indirect references when you want to track the relationship without actively controlling the point. If the point reference does not exist in the data source, the schedule does not control the device. > > Click `Save` to confirm the changes. > > ### Monitor schedule performance > > After saving point references, the schedule details page displays a `Point Trends` section that charts the occupancy status of all referenced points over a configurable date range. Each row shows the point name, device, current status (Occupied or UnOccupied), and a timeline bar. > > ![Schedule Details page showing Point Trends with Occupancy Cmd points for VAV devices, each displaying Occupied or UnOccupied status with orange and green timeline bars over a two-day period](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/schedules/kode-os-schedules-point-trends.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=dae515929f411d79234347813f661e3a) > > Point Trends shows the occupancy status timeline for all referenced points over the selected date range > > The `Point References` count in the header updates to reflect the total number of linked points (for example, `Point References (38)`). Click the download icon to export the trend data. > > ### Schedule command levels > > When a schedule is actively commanding a point, the command panel for that point shows the exact priority level the schedule is controlling. For example, if the schedule commands a point at level 9, the command panel displays level 9 with its current value. > > ![Command panel showing Occupancy Cmd variable with Occupied value, Action section with Priority set to Override, Value set to Occupied, Duration, Reason, Permanent checkbox, and Specific Reason fields, and Level 9 and 10 both showing Occupied as current value](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-command-panel.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=26ed72ae9f046054bb0d08b78214c604) > > The command panel shows the priority level and value at which the schedule is commanding the point > > This view confirms that the schedule is actively controlling the point. You can override the schedule's command by setting a higher priority level in the Action section. > > > [!NOTE] > > > > ### Command actions and priority levels > > > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > > > | Action | What it writes\* | Description | > > | - | - | - | > > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > > | `Set` | Fallback / default\* | Changes the fallback or default value. | > > | `Auto` | — | Clears an `Override` | > > | `Release` | — | Clears a `Set` | > > > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). > [tab] Calendar schedules > > ### Calendar schedules > > Calendar schedules define exception dates for holidays and special events. Create a calendar schedule to maintain a centralized list of holidays that can be [referenced by multiple weekly schedules](#reference-events). > > When creating a schedule, select `Calendar Schedule` as the type. > > ![Create New Schedule dialog with Calendar Schedule selected, Name set to Holiday Schedule, Folder set to Schedules, and Data Source set to Demo Jace](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-create-calendar.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=9997d1691d3573d75f2066c08fb79ad9) > > Select Calendar Schedule to create a holiday or special event schedule > > After creating a calendar schedule, the details page opens directly to the events list. > > ![Holiday Schedule details page showing an empty events list with Name, Type, and Value columns, and a New Event button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-empty.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=70073e981f3614b3412c55d046241905) > > A new calendar schedule shows an empty events list with a New Event button > > ### Event types > > Click `+ New Event` to add holiday or special event entries. The event type determines how the date is specified: > > **Date** -- use for holidays that fall on the same calendar date each year (for example, Independence Day on July 4). > > ![Add Special Event dialog with Name set to Independence Day, Type set to Date, Weekday set to Any, Day set to 4, Month set to July, and Year set to Any](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-date-event.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=4c9b5105aa8c5818fb4950722e996ab7) > > A Date type event targets a specific day and month, with an optional year > > **Week And Day** -- use for holidays that fall on a specific weekday and week of a month (for example, Thanksgiving on the fourth Thursday of November, or Memorial Day on the last Monday of May). > > ![Add Special Event dialog with Name set to Thanksgiving, Type set to Week And Day, Weekday set to Thursday, Week set to Week 4, and Month set to November](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-thanksgiving.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=00475a86dc052e3a5886eb1000b99203) > > A Week And Day type event targets a specific weekday, week, and month > > ![Edit Memorial Day dialog with Type set to Week And Day, Weekday set to Monday, Week set to Last 7 Days, and Month set to May](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-weekday-event.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=c11585cc0fa7d64dddb1920f463f67fe) > > Memorial Day uses Week And Day type with Last 7 Days to target the last Monday of May > > ### Manage calendar events > > The events list shows all configured holidays with their type, value, and options to edit or delete each event. Click `Reorder Events Priority` to change the priority order when multiple events overlap. > > ![Holiday Schedule events list showing Memorial Day (Week And Day), Independence Day (Date, July 4 Any), and Thanksgiving (Week And Day), with Reorder Events Priority button and edit/delete icons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-calendar-events-list.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=9771122d4944afbdf4d35f0cefdc6318) > > The calendar schedule events list shows all holidays with options to edit, delete, and reorder priority ## Discover existing schedules When you connect a data source that has schedules configured in the external building automation system, Cloud BMS can discover and import them. You can start discovery from the Schedules module or from the Data Sources page by clicking the three-dot menu on a data source row and selecting `Discover Schedules`. ![Data Sources page showing TR Fisnik data source with a three-dot menu open displaying Discover Devices, Discover Schedules, Edit, Duplicate, and Delete options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-datasource-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=abf6e1b556e7d074449250922c1b7c82) You can also start schedule discovery from the Data Sources page via the row menu **1. Start discovery** From the Schedules module, click the three-dot menu in the upper right corner and select `Discover Schedules`. ![Schedules list with the three-dot menu open showing Discover Schedules and Mass Write Schedules options](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-menu.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=122a55d8c4d74c179c5f6765d5e35939) The three-dot menu provides access to Discover Schedules and Mass Write Schedules **2. Select data sources** The Data Sources page shows all connected data sources with their discovery support status. Select the data sources you want to discover schedules from and click `Discover Schedules`. The Activity Log at the bottom tracks the discovery progress. ![Data Sources page showing TR Fisnik data source with Devices and Schedules discovery support, Tridium Niagara type, and Activity Log showing Completed status, with Discover Schedules and Discover Devices buttons](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-data-sources.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=4ef7c9031db510c6f9530c80020f5829) Select data sources and click Discover Schedules to start the discovery process **3. Review discovered schedules** The Schedule Discovery page displays discovered schedules separated into `New Schedules` and `Existing Schedules` tabs. Use the filter tabs to view schedules with no time periods, no references, or duplicate references. Search and select the schedules you want to import. ![Schedule Discovery page showing 242 new schedules and 8 existing schedules, with All, No Time Periods, No References, and Duplicate References filter tabs, a selected Weekly Events Schedule, and Add to Database button](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-results.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=806e64f7c046566d517f109070cb37c0) The Schedule Discovery page lists new and existing schedules with filter options and an Add to Database button **4. Add to database** Select the schedules you want to import and click `Add to Database`. A success notification confirms the schedules have been added. ![Success notification showing Saved Successfully with message that selected schedules have been added](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-success.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=6edfcce98ba6ae49af2a5ca81e9a1e69) A success notification confirms the selected schedules have been added The discovered schedules appear in the schedules list. Schedules without point references display a warning indicator. ![Schedules list showing newly added Weekly Events Schedule Test at the top with a 1 without point references warning, alongside four existing schedules with their current and next values](https://mintcdn.com/kodelabs/wYHWxi9OuQhq1u6c/images/kode-os/schedules/kode-os-schedules-discover-added.png?fit=max\&auto=format\&n=wYHWxi9OuQhq1u6c\&q=85\&s=7f227d1018611a5f11aeeed17b9e0d33) The schedules list shows the newly discovered schedule alongside existing schedules ## Driver capabilities Some schedule features depend on deeper synchronization with the source system. Capabilities differ based on whether the schedule driver is installed. For Niagara stations, see [Tridium Niagara](/products/integrations/controllers/niagara). | Capability | With driver | Without driver | | - | - | - | | Discover schedules and manage visibility (Hidden / Visible / All) | Yes | Discovery and list view still available | | Create schedules in Cloud BMS and sync to the source | Yes | Limited or unavailable | | Edit weekly time slots and properties | Yes | Partial (weekly slots and some properties) | | Add and manage special events | Yes | Limited; may be restricted to week references | | View Next Value Change (next change time and value) | Yes | Typically unavailable | | Delete schedules created in Cloud BMS | Yes | Limited | | Delete source-discovered schedules from Cloud BMS | May be restricted | May be restricted | ## Mass write schedules Mass write is a portfolio-level feature that allows you to update schedules and points in bulk across buildings. You can access it from the portfolio view or from the three-dot menu in the Schedules module by selecting `Mass Write Schedules`. > [card] [Mass write](/products/kode-os/mass-write) > > Write multiple points and update multiple schedules simultaneously across your portfolio. ## Optimized Start/Stop (OSS) OSS is an AI-powered module that calculates the optimal HVAC start time based on sensor data, weather conditions, and building characteristics. Instead of starting equipment at a fixed time, OSS predicts exactly when to start so the building reaches the target temperature by occupancy. OSS has its own dedicated section in the building sidebar. > [card] [Optimized Start/Stop (OSS)](/products/kode-os/oss) > > Configure OSS adapters, select operation modes, and monitor optimization performance. ## Next steps > [card] [Trends](/products/kode-os/trends) > > Chart historical point data to evaluate schedule effectiveness. > [card] [Devices](/products/kode-os/devices/devices) > > View and manage the equipment that schedules control. # Settings Source: https://docs.kodelabs.com/products/kode-os/settings Configure buildings, users, device types, units, and tags across your Cloud BMS portfolio. > [!NOTE] > > Settings is a portfolio-level module. Access it from the left navigation bar before selecting a building. Changes you make here apply across your entire Cloud BMS instance. The Settings module provides administrative configuration for your Cloud BMS instance. It manages buildings, users, device types, units, and tags that apply across your portfolio. ## Buildings The Buildings section provides detailed configuration for each building in your portfolio. ![Admin Settings Buildings page showing a list of buildings with picture, name, category, and address columns](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/buildings-list.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=8c7fcec0e8b5793ac4c3993e1ca7bca6) The Buildings page lists all buildings with their picture, name, category, and address **1. Navigate to buildings** Go to `Settings` and select `Buildings`. Use the search bar to find your building or browse the list. **2. View building details** Click a building name to access its configuration. Five tabs are available: * **Details** shows the building name, address, construction year, and category * **Areas** lists the floors, zones, and rooms (see the [areas documentation](/products/kode-os/areas) for management) * **Users** shows users assigned to this building * **Files** contains building-related documents and 3D BIM model files, with creation logs and file metadata * **Devices** lists devices associated with the building ### Add a BIM file Upload a 3D BIM model file on the building **Files** tab before you add it to an area dashboard. Supported formats include `.fbx` and other 3D file types your organization allows. **1. Open building files** Go to `Settings` and select `Buildings`. Click the building name, then open the `Files` tab. **2. Add a BIM model** Select the three-dot menu to the right of the search bar and choose `Add BIM Model`. Upload or select your 3D model file. ![Building Files tab in Admin Settings showing a file table with BIM Model and Floor Plan types and the three-dot menu open with Add BIM Model highlighted](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/kode-os-settings-building-files-add-bim.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=6bc099f3f8b006c3cc8ea37023133b83) The Files tab three-dot menu includes Add BIM Model for uploading 3D building models **3. Confirm the upload** After the upload completes, the file appears in the table with **Type** set to `BIM Model`. You can search and filter files using the search bar. The **Files** menu also supports `Add Floor Plan`, `Add Device File`, and `Add Building File` for other asset types. BIM files are used only with the [BIM Model widget](/products/kode-os/areas#add-a-bim-model-to-an-area) in Areas. **Name** `Column` File name as stored for the building (for example, an `.fbx` model file). **Type** `Column` File category. BIM uploads show as `BIM Model`. **Date Created** `Column` Timestamp when the file was uploaded. ### Manage building users From a building's `Users` tab, you can view all users assigned to that building and manage their access. ![Building Users tab showing a table of assigned users with name, email, position, role, and phone columns](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/building-users-tab.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=6a48837021d7fc572eb9b0609ab44dde) The Users tab shows assigned users with their name, email, position, role, and phone number Click `+ Assign Users` to add users to the building. Search for users by name, select or deselect them, and click `Save changes`. ### Device settings The **Devices** tab under a building's admin configuration controls how device detail pages behave for that building. Use it to set the default landing page, show or hide tabs and summary cards per canonical type, and control which points appear by default. Building-level settings apply to **all devices** in that building. Export and import configurations to reuse the same setup across your portfolio. **1. Open device settings** Go to **Settings** > **Buildings**, then click the building name. Open the **Devices** tab. Three customization sections are available: **Default Navigation**, **Tabs & Cards**, and **Point Visibility**. #### Default navigation Choose which page opens when a user opens a device. ![Devices tab showing Default Navigation options with Last Navigation, Trends, and Graphics radio buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/devices-default-navigation.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=7fa6622b922130002d19bfe34b3b296b) Default Navigation lets you choose the landing page for device details **Last Navigation** `Radio` The device opens to the last page the user visited on that device. This is the default setting. **Trends** `Radio` The device always opens to the **Trends** tab. **Graphics** `Radio` The device always opens to the **Graphics** tab. If no graphic is available for the device, it opens to **Trends** instead. Click **Save Changes** to apply your selection. #### Tabs and cards Configure which tabs and summary cards appear on device detail pages, organized by canonical device type. End users see only the tabs and cards you enable for that device's canonical type. ![Tabs and Cards configuration showing a matrix of device types and toggles for Graphics, Work Orders, FTT, FDD Events, Schedule, Referenced Devices, and Weather](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/devices-tabs-and-cards.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=696a0bf4fa90884ded5b4d6602fed07f) Tabs & Cards controls tab and card visibility per device type Each row represents a canonical device type (for example, `ahu`, `airQuality`, `coolingTower`). The columns are split into two groups: | Group | Options | | - | - | | **Tabs** | **Graphics**, **Work Orders**, **FTT** | | **Cards** | **FDD Events**, **Schedule**, **Referenced Devices**, **Weather** | Toggle each option to show or hide it for that canonical type. The **Trends** and **Device Details** tabs are always enabled and cannot be hidden. If you disable **Graphics** for a canonical type, that tab is hidden on matching devices. > [!TIP] > > Hide tabs and cards that are not relevant to specific equipment types. For example, disable **Work Orders** or **Weather** on device types where operators do not need them. Click **Save Changes** to apply your updates. #### Point visibility Control which points are visible by default on device detail pages. Configuration is based on **ontology field** and applies per canonical device type. ![Point Visibility configuration showing a device type dropdown, point name list grouped by ontology field, and show/hide toggles](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/devices-point-visibility.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=c519ee08b0bf590515b4df9c6ba7b2e8) Point Visibility lets you show or hide specific points per device type **1. Select a canonical type** Use the dropdown to select the canonical device type you want to configure (for example, `ahu`). **2. Filter and search** Optional: filter by **Status** — **All** or **In Use**. Use **Search** to find ontology fields quickly. **3. Set visibility** Points are grouped by ontology field. For each field, set **Show** (visible by default) or **Hidden** (hidden by default). Use **Show all** or **Hide all** within a group to bulk-toggle every field in that section. **4. Save changes** Click **Save Changes** to apply the updated visibility settings. On the device **Trends** tab, hidden points do not appear in the left panel by default. End users can reveal them with **Show Hidden**. #### Import and export device settings Export and import applies to all device customization settings: **Default Navigation**, **Tabs & Cards**, and **Point Visibility**. Use it to copy a proven configuration from one building to another. ![Import Device Settings with Sheet dialog showing a file upload area](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/devices-import-settings.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=e187e3d767482af026b9d139c4f0ab6b) The import dialog accepts a spreadsheet file with device settings **1. Export from a source building** Open the building's **Devices** tab. Click **Export Settings** to download the configuration as a CSV file. **2. Import into a target building** Open the target building's **Devices** tab. Click **Import Settings**, then upload or drag the CSV file into the dialog. Click **Import**. **3. Review and save** Review the imported changes, then click **Save Changes** to apply them. > [!TIP] > > Export settings from a fully configured building first, then import them into other buildings to standardize device pages across your portfolio. ## Users and permissions While user management is primarily handled through Launchpad, Cloud BMS also allows you to add and manage users directly. ### Add a new user **1. Navigate to users** Go to `Settings` from the left navigation bar. Select `Users` from the left side menu. **2. Start adding a user** Click `Add New User` at the bottom right of the page. **3. Complete user details** Fill in the required information: **User fields** | Field | Description | | - | - | | `First Name` | The user's first name | | `Last Name` | The user's last name | | `Email` | The user's email address (used for login) | | `Position` | Job title or role (optional) | | `Phone Number` | Contact phone number (optional) | | `User Role` | The permission level assigned to this user | | `Assign Buildings` | The buildings this user can access | **4. Save the user** Click `Save` to create the user account. ### Edit or remove a user Select a user from the `Users` page to view their details. The user details page shows their name, email, position, role, and phone number. ![User details page showing name, email, position, role, and phone with Edit User and Remove User buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/user-details.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=8497d3b2f60eebf9b90046f51d04bd06) The user details page provides Edit User and Remove User actions Click `Edit User` to update the user's details (name, position, phone, role) or click `Remove User` to delete the account. ### Assign users to buildings From the user details page, go to the `Buildings` tab next to the `Details` tab. Click `Assign Buildings` and check or uncheck the buildings this user should access. Click `Save changes`. ## Device types and units ### Device types Navigate to the `Device Types` page in settings to view all device types configured across your buildings. ![Admin Settings Device Types page showing a list of equipment types including Chiller, Cooling Tower, Heat Pump, and others](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/device-types.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=ded3bfedb5bc30c10abf27d93df7f118) The Device Types page lists all configured equipment types with a search bar and Add Type button **+ Add Type** `Button` Create a new device type by clicking `+ Add Type`, entering the name, and clicking `Save`. **Edit/Delete** `Menu` Hover over a device type and click the three-dot menu to edit or delete the type. ### Units The Units module manages measurement units for your devices. Navigate to `Units` in the settings menu to view all configured unit categories. ![Admin Settings Units page showing measurement categories like Concentration, Current, and Energy with their unit details](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/units.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=288fe1efc7d2468bfcf7646eb8400bc3) The Units page organizes measurements by category, each showing ID, symbol, keywords, COV tolerance, and precision Each unit category (for example, Concentration, Current, Energy) contains entries with: * **ID** (for example, `parts_per_million`) * **Symbol** (for example, `ppm`) * **Keywords** for search and filtering * **COV Tol.** (change of value tolerance) * **Precision** (decimal places) ## Tags Tags provide additional metadata for organizing and classifying devices and points. Navigate to the `Tags` page in settings to manage your tag library. ![Admin Settings Tags page showing a list of tags like power, coolingTower, pump, and sensor with their descriptions](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/settings/tags.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=2515c11489eb6cacfaffc124433f2160) The Tags page lists all tags with their name and description, searchable and sortable **+ Add Tag** `Button` Create a new tag by clicking `+ Add Tag`. Fill in the tag name (required) and description (required), then click `Save`. **Edit/Delete Tag** `Menu` Hover over a tag and click the three-dot menu to edit the tag details or delete it. ## Next steps > [card] [Introduction](/products/kode-os/get-started/introduction) > > Return to the platform overview and glossary. > [card] [Sites and map view](/products/kode-os/sites-and-map) > > Manage your building portfolio and navigate between sites. # Sites and map view Source: https://docs.kodelabs.com/products/kode-os/sites-and-map Navigate your building portfolio, access individual sites, and monitor portfolio-level health from the map view. The Sites module is the entry point to Cloud BMS and is accessible at the portfolio level. It displays all buildings in your portfolio as a list with an interactive map, providing a portfolio-level overview of building health and quick access to individual sites. Select a building to enter the building level, where you can access data sources, devices, systems, areas, graphics, schedules, and trends for that site. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR MAP[Portfolio Map] -- "select building" --> SITE[Building View] SITE -- "access" --> BBI[Building BI] SITE -- "access" --> FDD_M[FDD] SITE -- "access" --> FTT_M[FTT] SITE -- "access" --> SCH[Schedules] SITE -- "access" --> OSS_M[OSS] SITE -- "access" --> GFX[Graphic Tool] SITE -- "access" --> TR[Trends] SITE -- "access" --> SYS[Systems] SITE -- "access" --> AREA[Areas] SITE -- "access" --> DEV[Devices] SITE -- "access" --> DS[Data Sources] classDef sky stroke:#374D7C,fill:#E2EBFF,color:#374D7C classDef green fill:#B0E4CC,color:#285A48,stroke:#285A48 class MAP,SITE sky class BBI,FDD_M,FTT_M,SCH,OSS_M,GFX,TR,SYS,AREA,DEV,DS green ``` ## Navigate through sites The Sites page displays a scrollable building list on the left and an interactive map on the right. Each site card shows the building name, address, device-down count, and active event status. ![Sites list with search and sort controls next to the interactive portfolio map](https://mintcdn.com/kodelabs/z8J-7fbiFXxxCTJ3/images/kode-os/sites-and-map/sites-list-sort-map.png?fit=max\&auto=format\&n=z8J-7fbiFXxxCTJ3\&q=85\&s=080b762bb87b9e7b64acb429c21b8c03) The sites list and map view showing all buildings in the portfolio You can find and select a site in three ways: * **Search** using the search bar at the top of the sites list * **Browse** by scrolling through the building list on the left side * **Map** by clicking a building marker on the interactive map ### Search for a site Click the search bar and type a building name or address. The search options allow you to filter by `All`, `Name`, or `Address`. ![Sites search bar with All, Name, and Address filter options](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/sites-and-map/sites-search-options.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=ce3ce8158e46134883b98592b7f931f9) Search options let you filter by name, address, or both ### Sort sites Use the `Sort By` button to organize the site list: * **Sort order** -- ascending or descending * **Sort by** -- active events, down devices, building name, or created date ### Locate a site on the map Each site card in the list includes a location icon. Hover over a site card to reveal the `Locate on map` button. Click it to zoom the map to that building's position and display a popup with the address and status. ![Site card showing Locate on map button on hover](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/sites-and-map/locate-on-map.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=ad56eecbd85fea633ca454cd0def97ee) Hover over a site card to reveal the Locate on map action Click any building marker on the map to see a summary popup with the building name, address, device status, and active events. Click through to open that site's building view. ![Map view zoomed into a building with a summary popup showing address and device status](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/sites-and-map/map-building-popup.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=dcf5d789da1d6686a74c763fb27473dd) Click a map marker to view the building summary popup ### Switch between sites You can switch between sites directly while working within a specific site. The site switcher is located on the left side of the screen. Select a different site, and the page updates automatically without returning to the portfolio view. ## Map view The map on the right side of the Sites page provides a portfolio-level perspective of all your buildings. * **Building markers** appear on the map with color-coded health indicators (green for healthy, orange for warnings, red for critical issues) * **Zoom controls** in the upper-right corner let you zoom in, zoom out, and reset the view * **Marker popups** display the building name, address, device-down count, and active events when you click a marker ## Building overview When you select a site from the list or map, the building view opens with a summary of the site's key metrics and quick access to its modules: * **Systems** count and quick access to the systems module * **Areas** count with navigation to floor plans * **Devices** count with status summary (online, offline, in alarm) * **Points** count across all devices * **Data Sources** count with connectivity health For advanced analytics, custom widgets, and reporting, use Building BI from the building sidebar. ## Next steps > [card] [Data sources](/products/kode-os/data-sources) > > Set up and manage the integrations that feed data into your site. > [card] [Areas](/products/kode-os/areas) > > Define the spatial layout and floor plans for your building. # Systems Source: https://docs.kodelabs.com/products/kode-os/systems Organize and monitor devices by functional system groupings such as HVAC, Lighting, Fire, and Electrical in Cloud BMS. > [!NOTE] > > Systems is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its systems. Systems are logical groupings of devices organized by function. A building may contain HVAC, lighting, fire detection, electrical, plumbing, and other systems. Each system provides a centralized view of system-level health, making it easier to monitor, troubleshoot, and manage building operations. ## Navigate to systems **1. Select your site** Click `Sites` in the left navigation bar and select the building you want to manage. **2. Open the systems module** Click `Systems` in the left sidebar menu. The systems list displays all configured systems for the selected building. ![Systems list showing HWS and chilled water system entries with Name, Type, and Tags columns, a Reorder Systems dropdown, and a Create System button](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-list.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=3ea61f44ed79e25d96333503aa58ffe2) The Systems list shows all systems with their type and tags, plus options to search, reorder, and create **3. Select a system** Search for or select a system from the list to open its details view. ## Create a system Click `+ Create System` to open the creation dialog. ![Create System dialog with fields for System Name, Type dropdown, and Tags](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-create.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=1ff075da3028be0f513dd9ed3057ada8) The Create System dialog collects the system name, type, and tags **System Name** `Field` Enter a descriptive name for the system (for example, `Boiler 01`). **Type** `Field` Select the system type from the dropdown (for example, `Boiler`, `HWS`, `CHWS`). **Tags** `Field` Add tags to categorize and filter the system. Type a tag name and press enter to add it. After saving, the new system opens in its details view. The canvas is empty with a `+ Create New` button to add a graphic. Use the icons on the right sidebar to switch between views and access system details. ![Empty system view for chilled water system showing a Create New button in the center and view icons on the right sidebar](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-empty-state.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=d00c0eaf8542012e8304f2c9c0d3782c) A newly created system opens with an empty canvas ready for a graphic To reorder systems in the list, click `Reorder Systems` and drag them into the desired sequence. ## View options When you select a system, the system details view provides several perspectives. Switch between views using the icons on the right navigation bar. ### Graphics view The Graphics view displays the system schematic with live data overlaid on equipment components. Point values update in real time on the diagram. ![Systems Graphics view showing a chilled water system schematic with pipes, pumps, and chillers, and a data table with live point values](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-graphic-view.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=f210ae282774911bfe43c383d99c5f42) The Graphics view shows a chilled water system schematic with live point values displayed in a table alongside the diagram Click a writable point value on the graphic to open the command panel. The panel displays the device's variables on the left and the action form on the right. ![Command panel for HWS system showing Chilled Water Valve Percent Cmd, Hot Water Valve Percent Cmd, and Valve Closed Cmd variables on the left, with action fields for Priority, Value, Duration, Reason, and Specific Reason on the right, and current Level and Value at the bottom](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-command-panel-valve.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=9471d90d9cfb053d80d2d8b12777c3d4) The command panel shows device variables and the action form for overriding a point value * **Priority** -- select the command priority level (for example, `Override`) * **Value** -- set the target value. Use the dropdown for enumerated values (for example, `On` or `Off`). * **Duration** -- specify how long the command remains active. Check `Permanent` for an indefinite override. * **Reason** -- select a predefined reason from the dropdown * **Specific Reason** -- enter a custom reason for the change The bottom of the panel displays the current priority levels and values. Click `Save Changes` to send the command, or `Close` to cancel. Click `Activity Log` in the upper right corner to view the command history. > [!NOTE] > > ### Command actions and priority levels > > Cloud BMS uses a BACnet-inspired priority model for writable points. The same command dialog appears for BACnet and non-BACnet integrations, such as REST API thermostats. How each action maps on the device depends on the connector. > > BACnet points that accept commands have **16 priority levels** (1 is highest, 16 is lowest). When every level is empty (`null`), the point uses a **fallback / default** value (`Relinquish_Default` in BACnet). That fallback is **not** a 17th BACnet priority. Some interfaces label it as level 17 for display only. > > `Override` and `Set` turn different knobs under the hood, even when the visible value looks the same. > > | Action | What it writes\* | Description | > | - | - | - | > | `Override` | Priority 8\* | Temporary exception in the priority array. Takes precedence over lower-priority automation. | > | `Set` | Fallback / default\* | Changes the fallback or default value. | > | `Auto` | — | Clears an `Override` | > | `Release` | — | Clears a `Set` | > > \*Typical for most BACnet and Niagara deployments. Connectors and site standards can differ. > > The integration also limits which actions appear. Some APIs support `Set` only. Others support `Override` only. The command dialog lists the actions that connector allows. > > MQTT connectors that use the KODE command format accept priority 8 for `Override` and `Auto`, and priority 16 for `Set` and `Release`. > > `Override`, `Auto`, and `Set` borrow Niagara-style action names. `Release` is a Cloud BMS action that clears a `Set`. > > In Niagara-style control, `Set` keeps a non-null fallback so sequences and logic keep a reliable baseline. Use the priority array (including `Override`) for programmed automation and temporary exceptions. > > To make `Set` write to priority 16 instead of the fallback or default, enable **`Set in Slot16`** (Niagara) on the point. Configure that option from [device details](/products/kode-os/devices/devices#view-and-edit-points), [device templates](/products/kode-os/devices/device-templates), or [points batch update](/products/kode-os/points/points-batch-update). ### Dashboard view The Dashboard view charts system points over time, grouped by category (Temperature, Flowrate, and others). Each chart shows sensor and setpoint values with a configurable time range. ![Dashboard view showing a Temperature trend chart for Discharge Air Temp over the last two days, with a Flowrate section below](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-dashboard-view.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=f0c69b40e4f37beba2879950542aadb3) The Dashboard view displays point trends organized by category with downloadable charts ### Widget view The Widget view displays all system devices as cards with their current point values. Each card shows the device name and its key readings. ![Widget view showing device cards for VAV\_101, AHU\_3, FCU\_102, and FCU\_101 with their current point values](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-widget-view.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=04a4e58d3fa0725658ec449da7a05449) The Widget view shows all system devices as cards with live point values ## System details Click the information icon on the right sidebar to view the About System panel. ![About System panel showing system name HWS, type HWS, tags, and a Connected Systems section](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-about.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=d08dc744382740851e78251937113021) The About System panel shows system metadata including name, type, tags, and connected systems The panel contains two tabs: * **Information** -- displays the system name, type, tags, and connected systems * **Attachments** -- upload and manage photos, documents (submittals, O\&M manuals, as-built drawings), and notes Click the edit icon at the upper right of the panel to modify system properties. ### System devices Click the devices icon on the right sidebar to view all devices associated with the system. The panel lists each device with tabs for quick switching between them. ![System Devices panel showing VAV\_101 details with tabs for AHU\_3, FCU\_102, and FCU\_101](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-devices-panel.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=be9de4ee43c0550848b83d1191f91272) The System Devices panel shows device details including data source, name, location, type, area, and tags Click a device tab to view its details: Data Sources, Device Name, Location, Type, Area, and Tags. ## System-level health indicators Each system displays aggregate health information: * **Total devices** in the system * **Percentage online** showing the ratio of communicating devices * **Active alarms** indicating fault conditions across the system's equipment * **Communication score** reflecting overall data source reliability for the system ## Edit system graphics Click the three-dot menu on the right side of the Graphics view and select `Edit` to enter edit mode. You can also select `Delete` to remove the graphic. ![HWS system Graphics view showing a piping schematic with a three-dot menu expanded with Edit and Delete options](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/systems/kode-os-systems-graphic-menu.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=5df94439bd72160749a07cf159562407) The three-dot menu on the system graphic provides Edit and Delete options To modify the system graphic or add devices to the visual layout: **1. Enter edit mode** Click `Edit` from the three-dot menu to open the system graphic in the editor. **2. Modify the graphic** Upload a new system graphic, reposition existing devices, or add devices from the device list onto the schematic. See the [Graphic Tool](/products/kode-os/graphics/graphic-tool) for details on building system schematics with drawings, markers, and layers. **3. Save changes** Click `Save` to apply your changes to the system graphic. > [!TIP] > > System graphics provide a visual way to identify faults and monitor performance. Color-coded indicators on the graphic highlight online, offline, and alarming devices, making it fast to pinpoint issues without navigating to individual device details. ## How systems support fault detection Systems feed directly into Fault Detection and Diagnostics (FDD). When FDD rules are configured, the system grouping determines which devices are evaluated together. For example, an HVAC system's AHUs and VAVs are analyzed as a connected group, enabling detection of cascading faults that affect multiple devices. ## Next steps > [card] [Areas](/products/kode-os/areas) > > View devices organized by physical location rather than system function. > [card] [System graphics](/products/kode-os/graphics/system-graphics) > > Create and interact with schematic diagrams of building systems. # Trends Source: https://docs.kodelabs.com/products/kode-os/trends Chart historical point data with multi-point trending to monitor system performance, diagnose faults, and compare equipment behavior. > [!NOTE] > > Trends is a building-level module. Select a building from the [sites list](/products/kode-os/sites-and-map) to access its trends. Trends display historical time-series data for one or more points on a single chart. Multi-point trending allows you to overlay data from multiple devices, compare system behavior across time, and investigate anomalies. The feature supports customizable time ranges, zoom, interpolation, and data export. ## Access trends You can access trends from two locations: * **Device details** -- open a device's details page and click the `Trends` tab to see historical data for that device's points. From the summary bar, click `Faults` to open the [FDD Faults panel](/products/kode-os/devices/devices#view-faults-from-trends) for that device. * **Trends module** -- click `Trends` in the left sidebar menu to access the standalone multi-point trending interface ## Add points to a trend chart **1. Open the trends module** Click **`Trends`** in the left navigation bar to open the multi-point trending interface. **2. Select points** Use the left panel to filter points by **Area**, **Type**, **Point Field**, and **Device**. Search for specific points by name. Check the points you want to plot -- selected points appear on the chart immediately. Points under each device are grouped by ontology category, the same way as on [device details](/products/kode-os/devices/devices#trends-tab). Collapse a device to hide its points while you work through a long list. Use **Select all** to check every visible point under the current filters. Click **`Show Selected`** to view only the checked points grouped by device, or **`Clear Selection`** to reset. **3. Set the time range** Use the date picker at the top right of the chart to select the analysis period. The picker limits selection to periods that contain available data. Presets include **Last 2 Days**, **Last 7 Days**, and custom ranges. The granularity indicator (for example, `at 1 minute`) shows the current data resolution. ![Trends page showing filter panel on the left with Area, Type, Point Field, and Device filters, nine points selected across VAV\_101, VAV\_102, and VAV\_103, Combined Line and Bar chart tabs, line chart for numeric points in the upper section, and bar chart showing Occupancy Cmd status for three VAVs in the lower section](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/trends/kode-os-trends-overview.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=b3239bea9f60a9326038b71b1d917ae9) The Trends interface with point filters on the left, line and bar charts in the center, and time range controls at the top ## Chart layout The trend chart divides data into two visual sections: * **Upper section** displays numeric data (temperature, pressure, flow rate, valve position) as line charts. Switch between **Combined**, **Line**, and **Bar** tabs to change chart style. * **Lower section** displays binary or enumerated data as colored bar charts. Each state uses the point's configured read-map color. ## Raw data view Open the tabular view beside the chart when you need timestamped values instead of a plot. Raw data view supports ranges up to one week. Export the table to CSV when you need the numbers outside KODE OS. For longer ranges, keep using chart aggregation and [Export Point Timeseries](#export-trend-data) from the chart menu. ## Interact with the chart ### Zoom Use the zoom bar or your mouse scroll wheel to zoom into a specific time period. As you zoom in, the data resolution increases and more detailed readings become visible. ### Hover for values Hover over any point on the chart to see the exact data value and timestamp for all plotted points at that moment. ### Customize the Y-axis Configure two Y-axes to display different measurement types simultaneously. For example, show temperature on the left axis and flow rate on the right axis. ### Clickable legend Click any point name in the chart legend to hide or show that data series. This helps you focus on specific points without removing them from the chart. ## Data granularity Granularity adjusts automatically based on the selected time range: | Time Range | Granularity | | - | - | | 2 days | 2-minute intervals | | 7 days | 1-hour intervals | | 30 days | Daily intervals | > [!NOTE] > > Granularity applies only to the line chart and adjusts based on the selected date range. The system uses interpolation to fill gaps between data points, providing a smooth continuous trend line even when readings are not collected every minute. ## Chart configurations Open the **Configurations** panel from the right side of the chart to adjust display settings, aggregate functions, and Y-axis assignments. ### Settings * **Show tooltip** -- toggle the tooltip that appears when you hover over data points on the chart * **Interpolation** -- toggle interpolation to smooth the trend line between data points ### Aggregate functions When viewing trend data at lower resolutions, you can set the aggregate function per point field. Available options: * **Average** calculates the mean value over each interval * **Sum** totals the values within each interval * **Max** shows the highest value in each interval * **Min** shows the lowest value in each interval * **Count** shows the number of readings in each interval ### Y-axis assignment Assign each point field to the **Left** or **Right** Y-axis. Use separate axes when plotting different measurement types (for example, temperature on the left and flow rate on the right) so each series scales independently. ![Configurations panel showing Settings section with Show tooltip and Interpolation toggles enabled, Aggregate Function section with discharge\_air\_flowrate\_sensor and discharge\_air\_flowrate\_setpoint both set to AVERAGE, and Y-Axis section with both fields assigned to LEFT](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/trends/kode-os-trends-configurations.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=3f8a8f7a62a2636163640464e5adcccd) The Configurations panel controls tooltip, interpolation, aggregate functions, and Y-axis assignment per point field ## Save and share trend views Click the **three-dot** menu at the top right of the chart to access **Save View**, **Copy link to Trends**, and **Export Point Timeseries**. ![Three-dot menu showing Actions section with Save View, and Share section with Copy link to Trends and Export Point Timeseries](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/trends/kode-os-trends-actions-menu.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=8753858629f6f5ee6d85f30fefcb43de) The three-dot menu provides Save View, Copy link to Trends, and Export Point Timeseries ### Save a view Select **`Save View`** from the menu. Enter a **Name** for the view and check **`Public`** if you want to share it with other users. Click **`Save`** to store the configuration. > [!NOTE] > > Saved views can be accessed by everyone assigned on the building if they are public. ![Save View dialog with Name field set to VAV 1-3, Public checkbox checked, and Cancel and Save buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/kode-os/trends/kode-os-trends-save-view.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=0eaad4805ada5643eaa62bb27b27755a) Name the saved view and set it to Public for building-wide access Saved views preserve selected points, time range, filters, Y-axis settings, and aggregation preferences. Views support two time range modes: * **Dynamic** (for example, "Last 7 Days") always shows recent data relative to the current date * **Static** preserves a specific date range for consistent review ### Share a view Select **`Copy link to Trends`** from the menu to copy a shareable URL. Recipients see the same chart configuration and data. ### Export trend data Select **`Export Point Timeseries`** from the menu to download trend data as a CSV file. The export includes all plotted points with their timestamps and values for the selected time range. ## Use cases for multi-point trending The following scenarios demonstrate how building operators use multi-point trending to diagnose issues and optimize performance. ### Chilled water system optimization **Scenario:** The chilled water system comprises chillers, chilled water pumps, and sensors monitoring temperature and flow at key points. The building's energy manager wants to optimize chiller efficiency but notices inconsistent cooling throughout the building. **What to trend:** Plot the chilled water supply temperature (primary loop leaving temp), return temperature (primary loop entering temp), and run status for each chiller module. Include the AHU discharge air temperature and outside air temperature to see how efficiently cold water is distributed across zones. **Example devices and points** | Devices | Points | | - | - | | Chilled water loop | Primary loop entering temp, primary loop leaving temp | | HRV 1, HRV 2 | Discharge air temp, outside air temp, run status | | Chiller modules 1, 2, 3 | Run status | **What to look for:** Compare supply and return temperature differential against chiller run status. A narrowing delta-T while chillers are running indicates reduced heat transfer efficiency. Correlate AHU discharge temperatures with chilled water supply to identify distribution imbalances. ### Condenser water system monitoring **Scenario:** A large commercial building has a condenser water system with a cooling tower, condenser pumps, and temperature and pressure sensors. The operators notice the cooling tower is not maintaining the required condenser water temperature, leading to cooling inefficiencies. **What to trend:** Plot the condenser water return temperature, supply temperature, and condenser pump speed alongside outside air temperature and cooling tower fan percentage. **Example devices and points** | Devices | Points | | - | - | | Condenser water loop | Primary loop leaving temp, primary loop entering temp | | Cooling towers 1, 2 | Condenser fan percent, condenser fan status | | Chiller modules 1, 2, 3 | Run status | | HRV 1 | Outside air temp | **What to look for:** A rising return temperature despite adequate fan speed and favorable outdoor conditions suggests fouling or mechanical issues. By plotting these variables on a single chart, you can see how the return temperature fluctuates relative to outside air temperature and pump operation without switching between multiple views. ### Fan and AHU coordination **Scenario:** The building has multiple AHUs and fans providing ventilation across different floors. Energy usage spikes during peak occupancy hours, and the operations team wants to determine if fans and AHUs are operating efficiently. **What to trend:** Plot fan speeds, building static pressure, AHU discharge air temperatures, VAV discharge damper commands, discharge airflow, and zone temperatures. Include effective occupancy status for VAVs and FCUs to correlate with load patterns. **Example devices and points** | Devices | Points | | - | - | | HRV 2 | Outside air temp, discharge air temp, building static pressure, run status | | SVAV 2-1 | Discharge damper percent command, discharge airflow | | FCU 14-2 | Zone temp | | VAV, FCU | Effective occupancy | **What to look for:** Compare fan speed and static pressure against zone temperatures and damper positions. If static pressure drops while dampers are fully open, the AHU may be undersized for the current load. Correlate occupancy status with energy patterns to identify over-conditioning of unoccupied zones. > [!TIP] > > When plotting multiple points, start with related data from a single system. Adding unrelated points creates cluttered charts. Use the legend to toggle individual series on and off as you analyze different aspects of system behavior. If two points overlap on the chart, hover over the desired point in the legend to isolate it. ## Next steps > [card] [Schedules](/products/kode-os/schedules) > > Use trend data to evaluate and optimize equipment schedules. > [card] [Devices](/products/kode-os/devices/devices) > > Access device details and view trends for specific equipment. # Channel Partners Source: https://docs.kodelabs.com/products/launchpad/channel-partners/channel-partner-overview Manage client organizations and enable KODE OS products A channel partner is a reseller that provides KODE OS products to client organizations. In Launchpad, channel partners are primarily responsible for: * Creating and managing client organizations * Activating applications for client organizations (KODE OS) * Enabling KODE OS products for the buildings under those clients * Controlling which products each client can use and for which buildings * Adding new internal users * Configuring security settings * Setting up SSO * Managing the company profile The Home page provides an overview of your portfolio, including client count, building count, user count, total square footage, and total points. It also displays user security metrics and growth trends over time. ![Channel partner Home page with overview cards for clients, buildings, users, square feet, and points, user security metrics, and a growth chart](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-channel-partner-home.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=d61824657511e652c8f0e65e020d364f) The channel partner Home page shows portfolio-level metrics, user security status, and growth trends As a channel partner, you access Launchpad via your dedicated workspace address: ``` yourorganizationname.kodelabs.com ``` For workspace sign-in and activation, see [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ## Authentication logs The **Authentication Logs** page records all sign-in events across your organization. Each log entry shows the user name, email, date and time, status, identity provider, message, IP address, and browser agent. You can search and filter logs to investigate specific sign-in activity. ![Authentication Logs table showing columns for name, email, date and time, status, IDP, message, IP address, and agent](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-auth-logs-table.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=fa861756a0db4374491d8315920b0688) Authentication Logs displays a searchable, filterable record of all sign-in events Select a log entry to view the user's general information and full authorization history, including timestamps, IP addresses, applications accessed, and browser details. ![Authentication log detail page showing user general information and an authorizations table with date, IP address, status, application, message, and agent columns](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-auth-logs-detail.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=68c82895a20ac251af56cc30dccc5643) A user's log detail page shows general information and a table of all authorization events ## Company profile The **Company Profile** page displays your organization's general information, contact person, and preferences. You can edit each section using the `Edit` button. ![Company Profile page showing general information with name, access status, workspace domain, and address, contact person details, and default language preference](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-company-profile.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d09941e2667b8967339f87e77dff02cd) Company Profile shows organization details, primary contact, and language preferences ## Next Steps Learn how to create and manage clients and users as a channel partner. > [card] [Client Management](/products/launchpad/channel-partners/clients) > > Navigate the Clients page and manage client details, buildings, and users. > [card] [User Management](/products/launchpad/channel-partners/users) > > Create and manage Channel Partner users in Launchpad. > [card] [Enable products](/products/launchpad/channel-partners/product-enablement) > > Enable KODE OS products for clients and their buildings. # Clients Source: https://docs.kodelabs.com/products/launchpad/channel-partners/clients Learn how to create and manage new client organizations The **Clients** page, accessible from the left-hand sidebar, lists all existing clients in rows, with each row displaying key information about the respective client. You can create new clients from this page. Selecting a client opens a dedicated view for them, providing access to three sections: **Details**, **Buildings**, and **Users**. ![Clients table with columns for name, address, buildings, and users, with a search bar and Add Client button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=7666c1d1c66d036b208029c8d89f22c1) The Clients page lists all client organizations with name, address, building count, and user count ## Details This section provides an overview of the client organization and displays active application (`KODE OS`) and products currently enabled across their building portfolio. Use the **Details** section to: * View client-specific information and details * Activate or deactivate a client * Activate applications (`KODE OS`) * Bulk enable or disable products across the client's portfolio ![Client details page for ZEN Estate showing general information, KODE OS and myMSI app activation controls, contact person, and preferences](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-details-page.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a808da0821cd32135c41678c26cbccf4) The Details section shows general information, apps with activation status, contact person, and preferences ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Clients Table"] B1["Client A"] B2["Client B"] B3["Client C"] end subgraph s2["Client-Specific Sections"] D1["Client B Details"] D2["Client B Buildings"] D3["Client B Users"] end subgraph s3["Details & Products"] P1["Organization Details"] P3["Active Apps"] P2["Enabled Products"] end B2 -- access ----- D1 B2 --
      --- D2 & D3 D1 -- View & Manage --- P1 & P2 & P3 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:none,fill:none linkStyle 2 stroke:none,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00 ``` ## Buildings This section lists all buildings in the client's portfolio, where each building has a dedicated page for separate management. Use the **Buildings** section to: * View all buildings in the client's portfolio * View building-specific information and details * Enable or disable products for a specific building ![Buildings table showing building name, category, address, enabled products, timezone, and published status](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-buildings-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=de063229b6dc72abccb735d3d5ec46a6) The Buildings section lists each building with its category, address, enabled products, timezone, and status ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Clients Table"] B1["Client A"] B2["Client B"] B3["Client C"] end subgraph s2["Client-Specific Sections"] D1["Client B Details"] D2["Client B Buildings"] D3["Client B Users"] end subgraph s3["Client Buildings"] N1["Building 1"] N2["Building 2"] N3["Building 3"] end B2 --
      --- D1 B2 -- access --- D2 B2 --
      --- D3 D2 -- select --- N2 N2 -- View & Manage --- N12["Dedicated Page"] linkStyle 0 stroke:none,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:none,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#FF6D00 ``` ## Users This section lists all users in the client's Launchpad workspace, where each user has a dedicated page. User management is handled by the client organization, limiting channel partner capabilities to view-only access. Use the **Users** section to: * View all users in the client's Launchpad workspace * View user-specific information and details * View apps (`KODE OS`) assigned and their corresponding KODE OS role ![Users table showing name, email, position, role, user type, and active status](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-users-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=9fa6c527c83b238ef989c7b4e0dd1dc5) The Users section lists each user with their name, email, position, role, type, and status ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Clients Table"] B1["Client A"] B2["Client B"] B3["Client C"] end subgraph s2["Client-Specific Sections"] D1["Client B Details"] D2["Client B Buildings"] D3["Client B Users"] end subgraph s3["Client Users"] N1["User 1"] N2["User 2"] N3["User 3"] end B2 --
      --- D1 B2 --
      --- D2 B2 -- access --- D3 D3 -- select --- N2 N2 -- View --- N12["Dedicated Page"] linkStyle 0 stroke:none,fill:none linkStyle 1 stroke:none,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#FF6D00,fill:none ``` ## Create clients You can create clients directly from the **Clients** page using the `+Add Client` button. Follow the steps outlined below to create a new client organization. **1. Open the Clients page** Once inside Launchpad, navigate to the **Clients** page located in the left-hand sidebar. **2. Click +Add Client** Once inside **Clients** click the `+Add Client` button to open the client creation page. **3. Configure client details** Configure the required details for the new client. The form includes three sections: General Information, Address Information, and Contact Person. ![Add Client form with general information fields, address fields, and contact person fields](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-add-client-form.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=6626b8875b3f163a312a53447d2e6377) The Add Client form collects general information, address, and contact person details **Example Configuration** | Field | Example Configuration | | - | - | | Client Name | `Zen Estate` | | Workspace Domain | `zenestate.kodelabs.com` | | Country Code | `United States +1` | | Office Number | `+1 555 123 4567` | | Address | `225 Broadway, New York, New York, United States, 10007` | | Address Line 2 | `(This is optional)` | | City | `New York` | | State | `New York` | | Country | `United States` | | Zip | `10007` | | First Name | `Jane` | | Last Name | `Smith` | | Email | `jane.smith@zenestate.com` | | Country Code | `United States +1` | | Phone Number | `+1 555 987 6543` | Choose the workspace domain carefully. You cannot edit it after you save the client. The client picture, when used, must be a PNG. As you type an address, Launchpad shows suggestions. Select a suggestion to auto-fill the remaining address fields. **Contact Person** is for visibility only. Filling those fields does not create a Launchpad user account. **4. Save** Once you have configured the required client details, click `Save` to create the client. > [!NOTE] > > When you create a client, Launchpad automatically adds you to that client as an Admin. That grants Launchpad access only. You must still [assign the KODE OS app and role](/products/launchpad/client-organizations/users) before you can use KODE OS in that client. > [!NOTE] > > After you create a client, switch to the client's Launchpad workspace and create the buildings for that client. Then return to your channel partner view to activate KODE OS and enable products for the buildings you created. For more details, see [product enablement](/products/launchpad/channel-partners/product-enablement). # Product Enablement Source: https://docs.kodelabs.com/products/launchpad/channel-partners/product-enablement Learn how to activate KODE OS and enable products As a channel partner in Launchpad, one of your primary responsibilities is **activating KODE OS** and **enabling products** for client organizations. Before doing so, ensure the following prerequisites are met: * You already have existing clients in your Launchpad workspace. * Your clients have already added buildings to their Launchpad workspace. > [!NOTE] > > After you create a client, switch to the client's Launchpad workspace and create the buildings for that client. Then return to your channel partner view to activate KODE OS and enable products for the buildings you created. > [!NOTE] > > If you are a client organization, contact your KODE Labs representative to enable products for your buildings. ## Activate KODE OS Activation for client organizations is performed from a client's [Details section](/products/launchpad/channel-partners/clients#details) and must be completed individually for each client. To activate `KODE OS` for a client organization, follow the steps outlined below. **1. Open the Clients page** In Launchpad, navigate to the **Clients** page via the left-hand sidebar. **2. Select a client** Select a client from the list. You will be redirected to their **Details** section. **3. Activate KODE OS** In the **Details** section, locate **Apps** and click `Activate` for KODE OS. ![Client details page showing KODE OS and myMSI apps with Activate buttons and deactivated status](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-details-page.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a808da0821cd32135c41678c26cbccf4) The Apps section displays KODE OS and myMSI with their activation status A confirmation dialog appears. Click `Yes, Activate` to proceed. ![Activate App confirmation dialog with Cancel and Yes, Activate buttons](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-clients-activate-app-dialog.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=cea2ad9a49c132157c6170ff347d6136) Once `KODE OS` is active, the products available to you as a channel partner will appear, allowing you to proceed with enabling products for buildings in the client's portfolio. ## Enable Products As a channel partner, you can enable products either for multiple or all buildings in a client’s portfolio at once, or for a specific building individually. Product enablement is available from the [Details](/products/launchpad/channel-partners/clients#details) and [Buildings](/products/launchpad/channel-partners/clients#buildings) sections ### Enable Products via Details The client's **Details** section allows you to enable products across multiple or all buildings in the client's portfolio simultaneously. To do so, follow the steps outlined below: **1. Open the Clients page** In Launchpad, navigate to the **Clients** page via the left-hand sidebar. **2. Select a client** Select a client from the list. You will be redirected to their **Details** section. Assuming KODE OS is active, you should see product cards for all available products. ![Client details page with KODE OS active showing nine product cards including Cloud BMS, FTT, FDD, OSS, BBI, AssetOps, Building Data Hub, EnerG, and Document Hub](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-products-enabled.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=e62b56caea32951854a6181b587dac2f) The Details section shows all KODE OS products with building counts and Select Buildings controls **3. Click +Select Buildings on a product card** Each product card has a `+Select Buildings` button, allowing you to choose the buildings where the product should be enabled. A dialog opens where you search for and select the buildings to enable. ![Add Buildings to Enable FDD dialog with search bar, Select all option, and a building list showing title and address](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-products-select-buildings.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d68cffba8f8c6aa6ee6cb38a12304432) The Select Buildings dialog lets you search and select buildings for product enablement > [!NOTE] > > To disable a product across all buildings, click the icon and select `Mass Building Disablement`. > > ![Three-dot menu on a product card showing Mass Building Disablement option](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-products-mass-disable.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=7191abdab9d849aa3b17563175e6a5b8) **4. Save** After selecting the buildings, click `Save` to enable the product. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph Client2Info["Client-Specific Sections"] C1["Details Page"] C2["Buildings Page"] C3["Users Page"] end subgraph s1["KODE OS Products"] P1["Cloud BMS"] P2["AssetOps"] P3["FTT"] P4["FDD"] P5["OSS"] P6["EnerG"] P7["Building BI"] P8["Building Data Hub"] end A2["Client A"] -- enter --> C1 C1 -- activate --- K["KODE OS"] K -- available products --- s1 P1 -- Bulk Enable --- S1["Select Buildings"] P2 -- Bulk Enable --- S2["Select Buildings"] P3 -- Bulk Enable --- S3["Select Buildings"] P4 -- Bulk Enable --- S4["Select Buildings"] P5 -- Bulk Enable --- S5["Select Buildings"] P6 -- Bulk Enable --- S6["Select Buildings"] P7 -- Bulk Enable --- S7["Select Buildings"] P8 -- Bulk Enable --- S8["Select Buildings"] linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00 linkStyle 10 stroke:#FF6D00 linkStyle 9 stroke:#FF6D00 linkStyle 8 stroke:#FF6D00 linkStyle 7 stroke:#FF6D00 linkStyle 6 stroke:#FF6D00 linkStyle 5 stroke:#FF6D00 linkStyle 4 stroke:#FF6D00 linkStyle 3 stroke:#FF6D00 ``` ### Enable Products via Buildings The client's **Buildings** section allows you to enable products for individual buildings by selecting a building and activating products from its dedicated page. To do so, follow the steps outlined below: **1. Open the Clients page** In Launchpad, navigate to the **Clients** page via the left-hand sidebar. **2. Select a client** Select a client from the list. You will be redirected to their **Details** section by default. **3. Navigate to the Buildings section** Navigate to the client's **Buildings** section and select a building. **4. Enable products** Toggle on the products you want to enable for the selected building. The building page shows general information at the top and product cards with toggle controls at the bottom. ![Building dedicated page for KODE 1420 Office showing general information and product cards with on/off toggles for Cloud BMS, FTT, FDD, OSS, BBI, AssetOps, Building Data Hub, EnerG, and Document Hub](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-building-products-toggle.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=c08c528102934db921a2cfed5c8d9d7e) Each building page shows general details and product toggles for individual enablement ```mermaid actions={false} placement="bottom-left" theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph Client2Info["Client-Specific Pages"] C1["Details Page"] C2["Buildings Page"] C3["Users Page"] end subgraph s1["Client Buildings"] B1["Building 1"] end subgraph s2["KODE OS Products"] P1["Cloud BMS"] P2["AssetOps"] P3["FTT"] P4["FDD"] P5["OSS"] P6["EnerG"] P7["Building BI"] P8["Building Data Hub"] end A2["Client A"] -- enter --> C2 C2 -- view --- LB["List of Buildings"] LB -- select --- B1 B1 -- enter --- D1["Dedicated Page"] D1 -- enable --- P1 & P2 & P3 & P4 & P5 & P6 & P7 & P8 linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853 linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00,fill:none linkStyle 7 stroke:#FF6D00,fill:none linkStyle 8 stroke:#FF6D00,fill:none linkStyle 9 stroke:#FF6D00,fill:none linkStyle 10 stroke:#FF6D00,fill:none linkStyle 11 stroke:#FF6D00,fill:none ``` # Users Source: https://docs.kodelabs.com/products/launchpad/channel-partners/users Learn how to create and manage channel partner users The **Users** page, accessible from the left-hand sidebar, displays all users in your Launchpad workspace. It allows you to create new internal users directly, invite existing users from external organizations, and provides detailed controls for managing existing users regardless of origin. ![Users table showing columns for name, email, position, sign-in methods, type, role, status, created date, and MFA status with search, filters, and Add User controls](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5c8c162ab734a9282133e329fe3f1815) The Users page lists all users with name, email, position, sign-in methods, type, role, status, and MFA status You can filter the user list by status, MFA status, type, role, and sign-in method using the `Filters` panel. You can also bulk import users from a spreadsheet using the `Bulk import from .xlsx` option in the dropdown next to `+Add User`. ![Filters panel with dropdowns for status, MFA status, type, role, and sign-in method, alongside the bulk import option](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-filters.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=b7cc6011fc19c100a68596a0e28a67cb) The Filters panel lets you narrow the user list by status, MFA, type, role, and sign-in method ## User Types In Launchpad, users are categorized as either **Internal Users** or **Guest Users**. These profiles define a user's type and determine what can be managed for a given user. * Internal users represent entities whose account and user profile both reside within the same organization. Internal users authenticate directly using the credentials and sign-in methods issued by your organization. * Guest users represent entities whose user profile resides in your organization while their account resides in a different (external) organization. They continue to authenticate using the credentials and sign-in methods issued by their parent organization. ### When to use each type Use an internal user for someone who belongs to the channel partner. Create and authenticate that account in this organization. Invite that person into each client organization as a guest. They can switch between those client organizations from one account. Sign-in method and security settings stay with the organization where the user is internal. Guest access in other organizations follows that existing account. If the same person is an internal user in more than one organization, they must sign out and sign in again to switch organizations. Staying signed in can cause sign-in conflicts. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: TB theme: neutral --- flowchart LR %% Your Organization subgraph OrgA["Organization A"] IU_Profile["Internal User Profile"] EU_Profile["External User Profile"] IU_Account["Account"] end %% External Organization subgraph OrgB["Organization B"] EU_Account["Account"] end %% Connections IU_Account -. connected ..- IU_Profile IU_Profile -. connected .- IU_Account EU_Account -. connected ....- EU_Profile EU_Profile -. connected .- EU_Account %% Labels / Classes classDef internal stroke:#FF6D00,fill:none; classDef external stroke:#00C853,fill:none; class IU_Account,IU_Profile internal; class EU_Account,EU_Profile external; ``` ## Create Users You can create or invite users from the **Users** page using the `+Add User` button. The dropdown offers two options: `Add User` for internal users and `Invite User` for guest users. ![Add User dropdown showing Add User and Invite User options with descriptions](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-add-menu.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=b08a2480cd1cf2215c577dfe70350ed4) > [tab] Add User > > Create a new internal user in this channel partner organization. This creates a new account in the current organization. The user configures authentication with this organization's sign-in methods. > > The account setup email expires after 24 hours. Resend it from the user's three-dot menu. > > **1. Open the Users page** > > Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. > > **2. Click +Add User** > > Once inside **Users** click the `+Add User` button and select `Add User`. > > **3. Configure user details** > > Configure the required details for the new user. The form includes general information fields and active sign-in method selection. > > ![Add User form with fields for first name, last name, position, role, email, country code, phone number, account status toggle, access level, and active sign-in methods](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-add-form.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=07fca56713765222f4ca9bf77a162481) > > The Add User form collects personal details, account status, access level, and sign-in methods > > **Example Configuration** > > | Field | Example Configuration | > | - | - | > | First Name | `Jane` | > | Last Name | `Smith` | > | Position | `Facilities Manager` | > | Role | `Admin`, `Restricted`, `View Only` | > | Email | `jane.smith@example.com` | > | Country Code | `United States +1` | > | Phone Number | `555 123 4567` | > | Account Status (Toggle on to create the account right away. Leave off to postpone creation.) | `Toggle On/Off` | > | Access Level | `Permanent or Temporary` | > | Active Sign-In Methods | `Choose Sign-In Method` | > > **4. Save** > > Once you have configured the required user details, click `Save` to create the user. > [tab] Invite User > > Invite an existing user from a trusted organization as a guest. > > The guest receives an invitation to join this organization. They keep the authentication method from the organization where they are an internal user. > > The invitation stays open until they accept it or you delete the user. To send it again, delete the guest user and invite them again. Guests who have not accepted appear as `Pending`. > > **1. Open the Users page** > > Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. > > **2. Click +Add User** > > Once inside **Users** click the `+Add User` button and select `Invite User`. > > **3. Configure user details** > > Configure the required details for the new user. The form requires selecting a trusted organization and entering the guest user's email. > > ![Invite User form with fields for trusted organizations, email, position, role, and access level](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-invite-form.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=4b3ae21e12e428d1979e0af83cefc482) > > The Invite User form collects the trusted organization, email, position, role, and access level > > **Example Configuration** > > | Field | Example Configuration | > | - | - | > | Trusted Organizations (Select the trusted organization you will invite the user from) | `Acme Corp` | > | Email | `jane.smith@acme.com` | > | Position | `Facilities Manager` | > | Role | `Admin`, `Restricted`, `View Only` | > | Access Level | `Permanent or Temporary` | > > > [!NOTE] > > > > Sign-in methods are inherited from the parent organization and do not require configuration when inviting users. > > **4. Save** > > Once you have configured the required user details, click `Save` to invite the user. ## Manage Users The **Users** page lists all existing users in rows, with each row displaying key details about the respective user. Each user in your organization, whether internal or external, has a dedicated user page that provides a centralized interface to view and manage all details related to a specific user. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph s1["Channel Partner Users"] U1["User 1"] U2["User 2"] U3["User 3"] end A["Users Page"] -- view --- A1["Users Table"] A1 -- select ---- U1 U1 -- view & manage --- BIP1["Dedicated Page"] A1 -- select --- U2 & U3 U2 -- view & manage --- BIP2["Dedicated Page"] U3 -- view & manage --- BIP3["Dedicated Page"] linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00 ``` To manage a user, follow the steps outlined below: **1. Open the Users page** Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. **2. Select a user** Select a user from the list of users. You will be redirected to their **dedicated** page, which displays all general information for that user. ![User detail page showing general information with user name, email, phone number, status, role, position, invited date, trusted organization, and access level](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-users-detail-page.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5627276eff213fc3a61c13b0c4ac5812) A user's dedicated page shows general information including role, position, access level, and trusted organization **3. Manage the user** Once inside the user's dedicated page, you can complete the following actions: * Use the icon to edit user details. * Use the icon to manage the user, including deactivating or deleting them, changing their sign-in method, or resending the setup email. > [!NOTE] > > You can change the sign-in method or resend the setup email for internal users only. A guest invitation stays open until the guest accepts it or you delete the user. To send a guest invitation again, delete that user and invite them again. # Apps (KODE OS) Source: https://docs.kodelabs.com/products/launchpad/client-organizations/apps Learn how to create and manage buildings in your organization portfolio The **Apps** page, available from the left-hand sidebar, is where you manage **KODE OS**. In Launchpad, KODE OS is the primary application and consolidates all products into a single building operating system. Your channel partner activates KODE OS and enables products across your building portfolio. Once activated, you can assign KODE OS to users and specify a role that defines their permissions and allowed actions for each KODE OS product. ![Apps page showing KODE OS listed with Active status, activation date, URL, and number of assigned users](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-client-org-apps-table.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=f6dab9e464d01ab3376026de29426690) The Apps page displays KODE OS with its status, activation date, URL, and user count > [!NOTE] > > Only users with the **Admin** role in Launchpad can assign KODE OS and respective application roles. Refer to the list of [available Launchpad roles](/products/launchpad/get-started/accounts-and-users#user-roles) for client organizations. Selecting **KODE OS** gives you access to three sections: **Details**, **Roles**, and **Users**. ## Details This section provides an overview of KODE OS for your organization and the products enabled across your building portfolio. Use the **Details** section to: * View KODE OS application information * View which products are enabled for your organization ![KODE OS Details page displaying general information with name, activation date, users, URL, and status, followed by product cards showing Cloud BMS, FTT, FDD, OSS, BBI, AssetOps, Building Data Hub, EnerG, and Document Hub with the number of enabled buildings for each](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-client-org-apps-detail.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=7617c583d6247baafc4247568e93dcef) The KODE OS Details section shows application information and enabled products with building counts ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Apps"] A1["KODE OS"] end subgraph s2["KODE OS sections"] D1["Details"] D2["Roles"] D3["Users"] end subgraph s3["Details"] P1["Application Details"] P2["Enabled products"] end A1 --
      ----- D1 & D3 A1 --
      --- D2 D1 -- View ----- P1 & P2 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:none linkStyle 2 stroke:none,fill:none linkStyle 3 stroke:#FF6D00,fill: linkStyle 4 stroke:#FF6D00,fill:none ``` ## Roles This section lists the KODE OS roles in your organization. You can create roles and define per-product Read and Write permissions for each role. Use the **Roles** section to: * View all KODE OS roles * Create new roles and edit or delete existing ones * Define per-product permissions for each role See the [roles](/products/launchpad/client-organizations/apps#kode-os-roles) section for more details on KODE OS roles. ![KODE OS Roles page showing a table of roles including role name, description, and permissions count, with a search bar and Add Role button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-roles-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5d4a5a57c885ed9fe501926fc47abd24) The Roles page lists all KODE OS roles with their name, description, and number of permissions ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Apps"] A1["KODE OS"] end subgraph s2["KODE OS sections"] D1["Details"] D2["Roles"] D3["Users"] end subgraph s3["Roles"] P1["Role List"] P2["Role Creation"] end A1 --
      --- D1 & D3 A1 -- access --- D2 D2 -- View ----- P1 D2 -- Manage ----- P2 linkStyle 0 stroke:none,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 1 stroke:none,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00 ``` ## Users This section lists users in your organization and shows their KODE OS access and assigned role. You can assign KODE OS to users and change their role from here. Use the **Users** section to: * View which users have KODE OS access * View or change the role assigned to each user * Assign KODE OS to users who do not have access yet ![KODE OS Users page showing users grouped by role with expandable accordion sections for View Only, SuperAdmin, and other roles, with a search bar and Assign User button](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-client-org-app-users.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=03ef7e44322d0f5d6afc54a332b333e4) The Users page groups users by their assigned KODE OS role, with expandable sections for each role ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Apps"] A1["KODE OS"] end subgraph s2["KODE OS sections"] D1["Details"] D2["Roles"] D3["Users"] end subgraph s3["Users"] P1["Users by Assigned Role"] P2["Role assignment"] end A1 --
      --- D1 & D2 A1 -- access --- D3 D3 -- View ----- P1 D3 -- Manage ----- P2 linkStyle 0 stroke:none,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 1 stroke:none,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00 ``` ## KODE OS roles KODE OS uses Role-Based Access Control (RBAC) to govern what each user can access. Instead of assigning permissions individually to each user, you assign permissions to roles. Users then inherit those permissions based on the role assigned to them. A role defines permissions at the product level, letting you scope access to specific capabilities without granting full access to every product. > [!NOTE] > > A user in Launchpad can only have one `KODE OS` role assigned to them at a time. Selecting a role from the Roles page opens its detail page, where you can view the role name, description, and the full list of assigned permissions organized by group. > [!TIP] > > Module access such as Building BI edit comes from the Cloud BMS role permissions. Building assignment also limits which sites appear after sign-in. Change the role or buildings on the user record when someone reports missing sites or tools. ![Role detail page for Engineering Manager showing account details with name and description, and a permissions table with groups like Buildings, Areas, Dashboards, Datasources, Devices, and General with green Read and orange Write permission badges](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-role-detail.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=3eddd5403f93741630f4f7cc374f18eb) A role detail page shows account details and a permissions table with color-coded Read and Write indicators per group > [tab] Example 1 > > Three users have access to every product. Within each product, their role's **Read** and **Write** permissions define what they can view and do. > > ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} > --- > config: > layout: dagre > theme: neutral > --- > flowchart LR > CO["Client Organization"] --> users > > subgraph users["Users"] > direction TB > U1["User 1"] > U2["User 2"] > U3["User 3"] > U4["User 4"] > U5["User 5"] > end > > subgraph roles["KODE OS Roles"] > direction TB > R1["Admin"] > end > > U1 -- "Assigned Role" --> R1 > U2 -- "Assigned Role" --> R1 > U3 -- "Assigned Role" --> R1 > R1 -- "Per-product permissions" --> P1["Cloud BMS"] > R1 -- "Per-product permissions" --> P2["FTT"] > R1 -- "Per-product permissions" --> P3["FDD"] > R1 -- "Per-product permissions" --> P4["OSS"] > R1 -- "Per-product permissions" --> P5["BBI"] > R1 -- "Per-product permissions" --> P6["AssetOps"] > R1 -- "Per-product permissions" --> P7["Data Hub"] > R1 -- "Per-product permissions" --> P8["EnerG"] > > linkStyle 1,2,3 stroke:#00C853,fill:none > linkStyle 4,5,6,7,8,9,10,11 stroke:#FF6D00,fill:none > ``` > [tab] Example 2 > > Three users have access to reporting, diagnostics, energy, and monitoring products. Within each product, their role's **Read** and **Write** permissions define what they can view and do. > > ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} > --- > config: > layout: dagre > theme: neutral > --- > flowchart LR > subgraph users["Users"] > direction TB > U1["User 1"] > U2["User 2"] > U3["User 3"] > U4["User 4"] > U5["User 5"] > end > subgraph roles["KODE OS Roles"] > direction TB > R1["Analytics"] > end > CO["Client Organization"] --> users > U4 -- Assigned Role --> R1 > U5 -- Assigned Role --> R1 > R1 -- "Per-product permissions" --> P5["Cloud BMS"] & P1["BBI"] & P2["Data Hub"] & P3["EnerG"] & P4["FDD"] > > linkStyle 0 stroke:#00C853,fill:none > linkStyle 1 stroke:#00C853,fill:none > linkStyle 2 stroke:#00C853,fill:none > linkStyle 3 stroke:#FF6D00,fill:none > linkStyle 4 stroke:#FF6D00,fill:none > linkStyle 5 stroke:#FF6D00,fill:none > linkStyle 6 stroke:#FF6D00,fill:none > linkStyle 7 stroke:#FF6D00,fill:none > ``` ### Permission structure Permissions are organized into modules and submodules that correspond to KODE OS product areas. Each submodule supports two permission types: * **Read** -- enables users to view information or access specific features within a module (shown in green in the role editor) * **Write** -- grants users the ability to modify, create, or delete data and configurations within a module (shown in orange in the role editor) The permission modules include: > [accordion] Building BI > > Dashboards, Datasources, Sharings, Templates > [accordion] Building Data Hub > > Pipelines, Schedule > [accordion] Buildings > > General, Areas, Dashboards, Datasources, Devices, Miscellaneous, Points, Systems, Tags > [accordion] Maintenance > > General, Assets, Dashboard, Data Sources, Discovery Logs, Notification Policies, Schedule Logs, Schedules, Task Templates, Tasks > [accordion] Modules > > Admin, Audit, Connectivity, Dashboards, Deployment Audit, Energy Dashboard, FDD, FTT, Graphics, Marker Icons, Mass Write, MultiTrend, OSS, Schedules > [accordion] Users > > General (Get users, Assign buildings to users, Create users, Delete users) ## Create KODE OS roles Follow the steps outlined below to create a new `KODE OS` role. **1. Open KODE OS in Apps** From the left-hand sidebar, open **Apps** and select **KODE OS**. **2. Go to the Roles page** Within KODE OS, navigate to the **Roles** page. **3. Create a new role** Click `+Add Role` to start creating a new role. **4. Configure role details** Enter a **name** and **description** for the role, then define permissions. You can also click `Copy From Another Role` to base the new role on an existing one and modify the permissions as needed. ![Edit Role page showing name and description fields, a Copy From Another Role button, and a permissions section organized by product groups like BuildingBI and BuildingDataHub with Read and Write checkboxes for each submodule](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-edit-role.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=7b552caebea4ea317109a27d4b597654) The role editor shows General Information, a Copy From Another Role option, and per-product permissions with Read and Write checkboxes See the [permissions reference](/products/launchpad/client-organizations/apps/permissions-reference) for more details. **5. Save the role** Click **Save**. The role is now available when assigning KODE OS to users. ## Edit KODE OS roles To edit an existing role: **1. Select the role** From the Roles page, select the role you want to edit. The role detail page opens. **2. Click Edit** Click `Edit` to open the role editor. Modify the name, description, or permissions as needed. **3. Save changes** Click `Save` to apply the changes. Click `Cancel` to discard them. > [!NOTE] > > Some modules display a warning icon next to their name. Hover over the icon to see which permissions are connected and must be selected together. ## Delete KODE OS roles To delete a role, select it from the Roles page and click `Delete` on the role detail page. Confirm the deletion in the dialog. > [!WARNING] > > You cannot delete a role if users are still assigned to it. Reassign or remove those users before deleting the role. ## Assign KODE OS roles Follow the steps outlined below to assign KODE OS and a role to a user. **1. Open KODE OS in Apps** From the left-hand sidebar, open **Apps** and select **KODE OS**. **2. Go to the Users page** Within KODE OS, navigate to the **Users** page. **3. Assign a KODE OS role to a user** Click `+Assign User`, select the users, and click `+Assign User(s)` to confirm. ## Configure user management permissions You can control which roles are allowed to manage users in KODE OS by configuring the **Users > General** permissions within a role. This determines who can view, create, assign, and delete users, and optionally restricts those actions with constraints. **1. Open the role editor** Navigate to **Apps > KODE OS > Roles**, select the role you want to configure, and click `Edit`. **2. Navigate to Users permissions** In the Permissions section, scroll down to **Users > General**. You see Read and Write permission options for user management. ![Users General permissions showing Read permission with Get users and Constraints link, and Write permissions with Assign buildings to users, Create users, and Delete users checkboxes](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-role-user-permissions.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=051f3f17dde64422e7a356d5b1186857) The Users > General permissions section provides Read and Write controls for user management within KODE OS **3. Configure Read permissions** Check **Get users** under Read to allow users with this role to view other users. Click `Constraints` to restrict visibility to users assigned to the same buildings. ![Get users constraints dialog with AssignedInSameBuilding checkbox selected](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-role-constraint-building.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=f154995e8b4b8ed559a2759ef4689978) The Get users constraint limits visibility to users assigned to the same building **4. Configure Write permissions** Check the Write permissions to allow user management actions. Each permission can have constraints applied through the `Manage Constraints` link. ![Users General section with all Write permissions checked including Assign buildings to users, Create users with Manage Constraints link, and Delete users with Manage Constraints link](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-role-user-write.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=c2526747962d25b40629ec2cc8d774d4) Write permissions control user creation, deletion, and building assignment, with optional constraints for each **Assign buildings to users** `Toggle` Allows users with this role to assign buildings to other users. **Create users** `Toggle` Allows users with this role to create new users. Click `Manage Constraints` to restrict which roles the created users can have. **Delete users** `Toggle` Allows users with this role to delete users. Click `Manage Constraints` to restrict which roles can be deleted. **5. Set role constraints (optional)** For Create users and Delete users, click `Manage Constraints` to specify which roles the current role is allowed to create or delete. Select the `AllowedRoles` constraint and choose the permitted roles from the dropdown. ![Create users constraints dialog showing AllowedRoles constraint with IN operator and Engineering role selected](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-role-constraint-roles.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=55f7d471c9655c1493a7d210216610a5) The Create users constraint restricts which roles this role can assign to new users **6. Save** Click `Save` to apply the user management permissions for this role. ## Role constraints Beyond Read and Write permissions, KODE OS roles can include constraints that limit scope and visibility. Constraints appear next to eligible permissions in the role editor. Common constraint examples include: | Constraint focus | What it controls | | - | - | | Assigned buildings | Whether the user sees all buildings or only buildings assigned to them | | Published buildings | Whether the user sees all buildings or only published buildings | | Override duration | Maximum override duration when the role is allowed to override points | | Module visibility | Whether a module appears at portfolio level, building level, or both | | Client-facing views | Whether certain client-facing views are hidden for the role | | FDD event assignment | Whether users can acknowledge only assigned FDD events or any accessible FDD event | A Super Admin role typically sees all buildings regardless of individual assignment. A role limited to assigned buildings requires building assignment before those sites appear in KODE OS. The **Acknowledge FDD events** Write permission includes the `AssignedInEvent` constraint. Keep it enabled to limit acknowledgment to users assigned through the event's notification policy. Disable it for a role that needs to acknowledge any FDD event the user can access, including historical events without an assignee. To change the constraint, open **Apps > KODE OS > Roles** and edit the role. Find **Acknowledge FDD events** and click `Manage Constraints`. Select or clear `AssignedInEvent`, then click `Confirm` and save the role. ![Edit Role page for SuperAdmin with the Acknowledge FDD events constraint dialog open, showing Constraints and AssignedInEvent checkboxes](https://mintcdn.com/kodelabs/69TxUJ7F7ciVd9iN/images/launchpad/launchpad-client-org-role-constraint-assignedinevent.png?fit=max\&auto=format\&n=69TxUJ7F7ciVd9iN\&q=85\&s=053f3bba8732d29fe2956bbd2adec987) Manage Constraints on Acknowledge FDD events opens the AssignedInEvent constraint > [!NOTE] > > Changes to a role apply to every user assigned to that role. Launchpad Admins can change their own KODE OS role when they need to validate permissions. # Permissions Reference Source: https://docs.kodelabs.com/products/launchpad/client-organizations/apps/permissions-reference Reference for KODE OS role permissions by product ## Role Permissions Each role in **KODE OS** defines access through per-product permissions. Permissions are classified as `Read` or `Write` and determine what actions a user can perform on a resource. Use the permissions reference below to understand what permissions are available across `KODE OS` products. ### AssetOps Controls access to the AssetOps application for asset and maintenance operations. **General** **Get AssetOps** `Read` Access the AssetOps application. **Assets** **Get Assets** `Read` View assets and their details. **Delete Asset** `Write` Delete an asset. **Update Asset** `Write` Modify an existing asset. **Categories** **Get Categories** `Read` View asset categories. **Create Category** `Write` Create a new asset category. **Delete Category** `Write` Delete an asset category. **Update Category In Site** `Write` Update a category at the site level. **Update Category** `Write` Modify an existing category. **Closure Policies** **Get Closure Policies** `Read` View closure policies configured for AssetOps. **Update Site Closure Policies** `Write` Update closure policies at the site level. **Update Closure Policies** `Write` Modify existing closure policies. **Dashboard** **Get site Dashboard** `Read` View the AssetOps dashboard for a specific site. **Get Portfolio Dashboard** `Read` View the AssetOps dashboard at the portfolio level. **Data Sources** **Get Data Sources** `Read` View data sources connected to AssetOps. **Create Data Source** `Write` Add a new data source. **Delete Data Source** `Write` Remove a data source. **Discovery Configurations** **Get Discovery Configurations** `Read` View asset discovery configurations. **Update Discovery Configurations** `Write` Modify asset discovery configurations. **Discovery Logs** **Get Discovery Logs** `Read` View logs from asset discovery runs. **Initiate Discovery** `Write` Manually trigger an asset discovery run. **Discrepancy Reports** **Get Discrepancy Reports** `Read` View discrepancy reports generated by AssetOps. **Create Discrepancy Report** `Write` Generate a new discrepancy report. **Notification Policies** **Get Notification Policies** `Read` View notification policies configured for AssetOps. **Update Notification Policy** `Write` Modify existing notification policies. **Schedules** **Get Schedules** `Read` View maintenance schedules in AssetOps. **Create Schedule** `Write` Create a new maintenance schedule. **Delete Schedule** `Write` Delete a maintenance schedule. **Run Schedule** `Write` Manually trigger a maintenance schedule. **Task Templates** **Get Task Templates** `Read` View predefined task templates used for maintenance work. **Create Task Template** `Write` Create a new task template. **Delete Task Template** `Write` Delete an existing task template. **Teams** **Get Teams** `Read` View teams configured in AssetOps. **Create Team** `Write` Create a new team. **Delete Team** `Write` Delete a team. **Vendors** **Get Vendors** `Read` View vendors configured in AssetOps. **Create Vendors** `Write` Create new vendors. **Delete Vendors** `Write` Delete vendors. **Work Orders** **Get Work Orders** `Read` View work orders in AssetOps. **Create Work Order** `Write` Create a new work order. **Delete Work Order** `Write` Delete a work order. **Update Work Order** `Write` Update an existing work order. **Update Task List** `Write` Update the task list associated with a work order. ### Building BI Controls access to the Building BI application for analytics dashboards and reporting. **Dashboards** **Get Dashboards** `Read` Retrieve and view all dashboards. Portfolio-level or building-level access control can restrict visibility. **Manage Collections** `Write` Manage dashboard collections, including reordering, creating, editing, deleting, publishing, and managing viewers. **Create Dashboards** `Write` Create new dashboards within Building BI. **Datasources** **Get Datasources** `Read` View all data sources (both physical and virtual) within Building BI. **Create physical datasources** `Write` Add physical data sources. **Create virtual datasources** `Write` Create virtual data sources by writing queries on top of existing data sources. **Replace datasources** `Write` Move dashboard, widget, and filter references from one data source to another. **Delete datasources** `Write` Delete both physical and virtual data sources. **Deployment Manager** **Get Deployments** `Read` View dashboard deployment configurations and status. **Create Dashboard Bulk Deployments** `Write` Create bulk deployments of dashboards across buildings or portfolios. **Schedules** **Schedule PDF Reports** `Read` View and access scheduled PDF report configurations. **Sharings** **Share Links** `Read` Generate public, shareable links to dashboards or widgets for external users. **Templates** **Get Templates** `Read` View and select from all available dashboard templates. **Create templates** `Write` Save dashboards or views as templates for reuse. **Delete templates** `Write` Delete existing templates. ### BuildingDataHub Controls access to the Building Data Hub for data pipelines and scheduled jobs. **Pipelines** **Get Pipelines** `Read` View data pipelines configured in the Building Data Hub. **Create Pipelines** `Write` Create new data pipelines. **Schedule** **Get Schedules** `Read` View scheduled jobs for data pipeline execution. **Create Schedules** `Write` Create new scheduled jobs for data pipelines. ### EnerG Controls access to energy monitoring, reporting, and analytics across buildings and portfolios. **General** **Get EnerG** `Read` Access the EnerG application. **View Energy Hub** `Read` Access the Energy Hub module for centralized energy analytics across buildings. **Edit Energy Hub** `Write` Configure, customize, or update data sources, settings, and key performance indicators in the Energy Hub. **Alert Center** **Get Alert Center** `Read` View configurations and active notifications for this module. **Edit Alert Center Configurations** `Write` Modify settings and rules for this module. **Enable Alert Center Module** `Write` Enable or disable this module. **Take Actions On Alerts** `Write` Acknowledge, resolve, or perform other actions on notifications. **Baseline Configuration** **Get Baseline Configuration** `Read` View baseline configurations used for energy comparison. **Create Baseline Configuration** `Write` Create new baseline configurations. **Benchmarking** **Get Benchmarking** `Read` View benchmarking data and comparisons. **Budget** **Get Budget** `Read` View budget configurations and energy budget data. **Create Building Budget** `Write` Create a budget for a building. **Delete Building Budget** `Write` Delete a building budget. **Building Dashboards** **Get Building Budget Dashboard** `Read` View the building budget dashboard. **Get Building Comparison Dashboard** `Read` View the building comparison dashboard. **Get Building Cost Dashboard** `Read` View the building cost dashboard. **Get Building Data Quality Dashboard** `Read` View data quality metrics for building energy data. **Get Building Data Table** `Read` View building energy data in table format. **Get Building Emissions Dashboard** `Read` View carbon emissions and sustainability metrics for a building. **Get Building Interval Trends Dashboard** `Read` View interval-level energy trends for a building. **Get Building Target Dashboard** `Read` View building target and goal tracking. **Get Building Usage Dashboard** `Read` View building energy usage dashboard. **Get Building Weather Normalization Dashboard** `Read` View weather-normalized energy metrics for a building. **Create Export Template Building Data Table** `Write` Create an export template for building data table exports. **Delete Export Template Building Data Table** `Write` Delete an export template for building data tables. **Export Building Data Table** `Write` Export building energy data to a file. **Building Information** **Get Building Information** `Read` View building information configured in EnerG. **Edit Building Information** `Write` Edit building information in EnerG. **Capital Plans** **Get Capital Planning** `Read` View capital planning data and configurations. **Create Capital Planning** `Write` Create capital planning entries. **Delete Capital Planning** `Write` Delete capital planning entries. **Certifications** **Get Certifications** `Read` View sustainability and energy certifications. **Create Certifications** `Write` Create or register certifications. **Data Sources** **Get Accounts** `Read` View energy accounts. **Get Bills** `Read` View bill data. **Get Buildings** `Read` View buildings linked to EnerG data sources. **Get Credentials** `Read` View credential metadata for data source connections. **Get Data Sources** `Read` View configured energy data sources. **Get Meters** `Read` View energy meter records associated with data sources. **Get Providers** `Read` View energy data providers. **Get Statements** `Read` View billing or usage statements. **Activate And Deactivate Accounts** `Write` Activate or deactivate energy accounts. **Add Credentials** `Write` Add credentials for data source connections. **Assign And Unassign Accounts** `Write` Assign or remove account assignments to buildings or portfolios. **Assign And Unassign Meters** `Write` Assign or remove meter assignments to buildings or data sources. **Create Account** `Write` Create a new energy account. **Create Connect Url** `Write` Create connection URLs for data source integration. **Create Data Sources** `Write` Create new energy data sources. **Create Meter** `Write` Create a new meter. **Delete Data Sources** `Write` Delete energy data sources. **Link And Unlink Buildings** `Write` Link or unlink buildings to data sources or accounts. **Upload Bills** `Write` Upload bill documents or data. **Energy Modeling** **Get Energy Modeling** `Read` View energy modeling configurations and results. **Create Energy Modeling** `Write` Create energy models. **Delete Energy Modeling** `Write` Delete energy modeling configurations. **Meters** **Get Link Meters** `Read` View linked meter configurations. **Get Meter Completeness** `Read` View meter data completeness metrics. **Get Meters** `Read` View energy meter records and meter metadata. **Get Meters Comparison** `Read` View meter comparison configurations. **Create Meters Comparison** `Write` Create meter comparison configurations. **Delete Meters Comparison** `Write` Delete meter comparison configurations. **Edit Link Meters** `Write` Edit linked meter configurations. **Edit Meters** `Write` Edit meter configurations. **Edit Virtual Meters** `Write` Edit virtual meter definitions. **Meters Dashboards** **Get Meter Data Quality Dashboard** `Read` View meter data quality dashboard. **Get Meter Data Table** `Read` View meter data in table format. **Get Meter Interval Trends Dashboard** `Read` View interval-level trends for metering devices. **Get Meter Completeness** `Read` View meter completeness metrics in dashboard context. **Get Meter Usage Dashboard** `Read` View meter usage dashboard. **Create Export Template Meter Data Table** `Write` Create an export template for meter data table exports. **Delete Export Template Meter Data Table** `Write` Delete an export template for meter data tables. **Export Meter Data Table** `Write` Export meter data to a file. **Meters Data** **Get Meters Data** `Read` View raw or aggregated meter data. **Edit Meters Data** `Write` Edit or correct meter data. **Portfolio Dashboards** **Get Portfolio Cost Dashboard** `Read` View portfolio-level cost dashboard. **Get Data Table** `Read` View portfolio energy data table. **Get Portfolio Emissions Dashboard** `Read` View portfolio emissions dashboard. **Get Portfolio Target Dashboard** `Read` View portfolio target dashboard. **Get Portfolio Usage Dashboard** `Read` View portfolio usage dashboard. **Get Portfolio Weather Normalization Dashboard** `Read` View portfolio weather normalization dashboard. **Create Export Template Portfolio Data Table** `Write` Create an export template for portfolio data table exports. **Delete Export Template Portfolio Data Table** `Write` Delete an export template for portfolio data tables. **Export Portfolio Data Table** `Write` Export portfolio energy data to a file. **Targets** **Get Targets** `Read` View energy or sustainability targets. **Create Targets** `Write` Create new targets. **Delete Targets** `Write` Delete targets. ### Buildings Controls access to building-level data, devices, systems, and configuration. **General** **Get buildings** `Read` View the list of buildings assigned to the user when logging into KODE OS. **Manage attachments related to buildings** `Write` View, upload, and delete documents or media files attached to buildings, systems, or devices. **Assign users to buildings** `Write` Assign or revoke user access to specific buildings. **Areas** **Get areas** `Read` View the Areas module in the side panel and list areas within a building. **Create areas** `Write` Define and create new areas (zones, rooms, floors) within a building. **Create area dashboards** `Write` Create dashboards specific to an area, available in the area detail page. **Delete areas** `Write` Delete existing areas from the building layout. **Delete area dashboards** `Write` Delete dashboards created within the context of an area. **Datasources** **Get datasources** `Read` View the Data Sources module and all configured sources within a building. **Create datasources** `Write` Create new data sources within the building context. **Delete datasources** `Write` Delete existing data sources from a building. **Clear datasource cache** `Write` Manually clear the cached data of data sources to refresh stale or outdated data. **Discover data source devices** `Write` Run device discovery from a data source and import discovered devices, points, and schedules into KODE OS. **Discover datasource devices via sheet** `Write` Import devices from a sheet-based source into the building. **Devices** **Get devices** `Read` View the Devices module for a building and access all devices and their associated points. **Get device types** `Read` View all available device types, including system-defined and custom types. **Get linked devices** `Read` Retrieve the list of linked devices (device-to-device or device-to-system relationships). **Get device graphic templates** `Read` View available device graphic templates for visual representation of devices. **Get building device graphics** `Read` View the graphical representation of devices from the device details page. **Get Manual Meters** `Read` View manually entered meter definitions in the building. **Get Manual Readings** `Read` View manually entered meter readings. **Manage device types** `Write` Create, modify, or delete custom device types used across the platform. **Manage device and system attachments** `Write` Attach or detach devices to systems or locations within a building. **Update devices** `Write` Modify device configurations, including metadata and mappings. **Delete devices** `Write` Permanently delete devices from the building. **Manage linked devices** `Write` Access and manage the Linked Devices module, including creating or removing device associations. **Manage virtual devices** `Write` Create, update, or delete virtual devices (aggregated or logical devices built from multiple data points). **Manage device and point templating** `Write` Configure device and point mappings to standardized ontology templates. **Manage AI-assisted templating** `Write` Configure AI-assisted device and point templating. **Manage device metadata** `Write` Edit device metadata and custom attributes. **Create Manual Meters** `Write` Create manually entered meter definitions. **Update Manual Meters** `Write` Update manually entered meter definitions. **Delete Manual Meters** `Write` Delete manually entered meter definitions. **Write Manual Readings** `Write` Enter or update manual meter readings. **Delete Manual Readings** `Write` Delete manually entered meter readings. **Create device graphic templates** `Write` Create new graphic templates for devices. **Update device graphics** `Write` Modify device graphics in the graphics interface. **Delete device graphic templates** `Write` Delete existing graphic templates. **Delete device graphics** `Write` Delete individual graphics assigned to devices. **Points** **Get points** `Read` Access the Points module and view all points (sensors, commands, statuses) associated with devices. **Get point units** `Read` View the measurement units associated with points. **Update points** `Write` Modify point configurations, such as renaming, reconfiguring units, or modifying descriptions. **Delete points** `Write` Remove points from a device or system. **Write points** `Write` Send commands or perform manual overrides on writable points (for example, temperature set points or mode changes). **Manage point units** `Write` Create, edit, or delete custom point units used across devices. **Space Assignments** **Get space assignments** `Read` View space assignment configurations linking spaces to users or other entities. **Create space assignment** `Write` Create new space assignments. **Update space assignment** `Write` Modify existing space assignments. **Delete space assignment** `Write` Remove space assignments. **Areas (Spaces)** **Get areas** `Read` View areas in the space context. **Create areas** `Write` Create new areas in the space context. **Create space dashboards** `Write` Create dashboards within a space. **Delete areas** `Write` Delete areas in the space context. **Delete space areas** `Write` Delete space-level areas. **Manage area attachments** `Write` View, upload, or delete attachments on areas. **Update areas** `Write` Modify existing areas in the space context. **Systems** **Get systems** `Read` Access the Systems module and view mechanical, electrical, or logical systems in a building. **Create systems** `Write` Define and create new systems within a building. **Delete systems** `Write` Remove systems and their relationships from a building. **Tags** **Get tags** `Read` View all existing tags in the Admin module. **Create tags** `Write` Create new tags for classifying assets, devices, and other elements. **Delete tags** `Write` Delete tags from the Admin module. **Miscellaneous** **Get notifications** `Read` Retrieve and view system-generated notifications (alerts, updates, warnings) related to buildings. **Get geocode address** `Read` Retrieve the geolocation and address of a building. **Get weather data** `Read` Retrieve real-time weather data integrated with the building's location. **Dashboards** **Get dashboards** `Read` View building-level dashboards. **Create dashboards** `Write` Create building-level dashboards. **Delete dashboards** `Write` Delete building-level dashboards. ### Modules Controls access to core KODE OS platform features such as FDD, FTT, graphics, schedules, trends, admin, and connectivity. **Tenants** **Get tenants** `Read` View tenants in the portfolio. **Get building tenants** `Read` View tenants assigned to a building. **Assign buildings to tenant** `Write` Assign buildings to a workspace. **Create tenant** `Write` Create a new workspace. **Delete tenant** `Write` Delete a workspace. **Update tenant** `Write` Update workspace details. **Admin** **Access admin panel** `Read` Access the Admin panel from the portfolio view. **FDDV2** **Get FDD events** `Read` Track events and receive associated notifications for proactive operational awareness. **Get FDD routines** `Read` View the list of custom routines used for equipment monitoring. **Get FDD configs** `Read` View FDD system configurations, including which routines run for monitoring equipment. **Export FDD configs** `Read` Export FDD configurations. **Get FDD notification policy** `Read` View notification policies that define who receives notifications, message content, and delivery method. **Get FDD Event Routine View** `Read` View the FDD event routine view. **Get Faults** `Read` View fault records. **Get Faults Comments** `Read` View comments on faults. **Get Faults Activity Logs** `Read` View activity logs for faults. **Get Faults Triage Rules** `Read` View fault triage rules. **Get WorkOrder List** `Read` View the list of work orders linked to FDD events. **Notify users through phone call** `Read` Initiate phone calls to notify users about important events. **Notify users through phone text message** `Read` Send SMS alerts to designated recipients when specific events occur. **Acknowledge FDD events** `Write` Mark an event as acknowledged. The `AssignedInEvent` constraint is enabled by default and limits acknowledgment to assigned users. Disable the constraint for a role that needs to acknowledge any accessible FDD event, including historical events without an assignee. **Create FDD configs** `Write` Configure FDD settings to define which equipment FDD monitors and establish notification thresholds. **Create FDD notification policy** `Write` Create and modify building-level notification policies, including delivery method (email, push, SMS, or phone call). **Create FDD Portfolio notification policy** `Write` Create and modify notification policies at the portfolio level for reuse across multiple buildings. **Create FDD routines** `Write` Create custom routines using the logic block programming tool for automated building operations. **Delete FDD notification policy** `Write` Delete notification policies at the building level. **Delete FDD Portfolio notification policy** `Write` Delete notification policies applied at the portfolio level. **Delete FDD routines** `Write` Remove custom-created FDD routines. Library routines aren't affected. **Import Export FDD routines** `Write` Import and export routines between portfolios for managing custom libraries. **Manual Run Jobs** `Write` Manually trigger FDD jobs. **Send or resend external-push** `Write` Send or resend push notifications to third-party systems for integrating FDD events with work order platforms. **Update Faults Triage Rules** `Write` Create or update fault triage rules. **Update faults metadata** `Write` Update metadata on fault records. **Upsert FDD Ack Event Preferences** `Write` Set the portfolio-level SLA response time for acknowledging events and comment requirements. **Upsert FDD Building Dashboard Filters Preferences** `Write` Set default filters for other users on the building-level FDD dashboard. **Upsert FDD Portfolio Dashboard Filters Preferences** `Write` Set default filters on the portfolio-level FDD dashboard for all users. **Upsert FDD Portfolio TableView Preferences** `Write` Set portfolio-level table view preferences for the FDD dashboard. **Upsert/Hide priorities** `Write` Customize the names and colors used to represent priorities within the portfolio. **FTT** **Get FTT workflows** `Read` View the custom workflows used to perform functional tests on equipment. **Get FTT projects** `Read` View all FTT projects created for the building or portfolio. **Get FTT history** `Read` View test results and data from tests performed within the system. **Get FTT WorkOrder List** `Read` View the list of work orders linked to FTT. **Create FTT workflows** `Write` Create custom functional testing workflows using the logic block programming tool. **Delete FTT workflow** `Write` Remove custom functional testing workflows. Library workflows aren't affected. **Create FTT Projects** `Write` Schedule tests across multiple devices, floors, or an entire building. **Run/Stop tasks manually** `Write` Control the manual start or stop of testing after you enable a scheduled project. **Run manual test** `Write` Test the functionality of a specific device for targeted troubleshooting. **View FTT Parameters for Manual Test** `Write` Show and edit workflow parameters when running an on-demand (manual) test. This permission is separate from **Run manual test**. It applies only to manual tests, not project task parameter overrides. When this permission is off, users can still start a preconfigured manual test, but its parameters remain hidden. **Archive FTT tests** `Write` Mark a result as archived, commonly used during initial setup or when handling inconclusive results. **Update FTT concurrently running tests** `Write` Set the number of devices tested concurrently within a single task (1 to 5, default is 3). **Import and Export FTT Workflows** `Write` Import and export workflows to manage custom libraries across portfolios. **Send external push or resend an existing one** `Write` Send or resend push notifications to third-party systems for FTT results. **Upsert FTT Building Dashboard Filters Preferences** `Write` Set default filters for other users on the building-level FTT dashboard. **Upsert FTT Portfolio Dashboard Filters Preferences** `Write` Set default filters on the portfolio-level FTT dashboard for all users. **GraphicsV1** **Get Old Graphics (V1)** `Read` View legacy (V1) graphics in system and device details. **GraphicsV2** **Get Graphics** `Read` View graphics in system and device details. **Get Area Graphics** `Read` View graphics associated with areas. **Get Device Graphics** `Read` View graphics associated with devices. **Get System Graphics** `Read` View graphics associated with systems. **Edit Graphics** `Write` Access the Graphics module from the main left menu and modify floor plans, system, and device graphics. **Share Dashboards** `Write` Share dashboard views from the graphics context. **SchedulesV2** **Get schedules** `Read` View the Schedules module and schedule details of a building. **Create schedules** `Write` Create new schedules. **Update schedules** `Write` Update existing schedules. **Duplicate schedules** `Write` Duplicate a schedule. **Discover schedules** `Write` Discover schedules from data sources and import them to KODE OS. **Sync schedules** `Write` Sync schedule updates from the data source. **Delete schedules** `Write` Delete schedules. **MultiTrend** **Get Trends** `Read` Access the Trends module. **Publish Configurations** `Write` Create views on the Trends module. **OSS** **Get OSS results** `Read` View Optimal Set Point Strategy (OSS) results. **Create OSS configs** `Write` Create OSS configurations. **MassWrite** **Get points latest configs** `Read` View the past jobs for writing points from the portfolio view. **Get schedules latest configs** `Read` View the past jobs for modifying schedules from the portfolio view. **Initiate schedule mass write** `Write` Initiate a job for mass modifying schedules on buildings you can access from the portfolio view. **Initiate point mass write** `Write` Initiate a job for mass writing points on buildings you can access from the portfolio view. **Audit** **Get audit templates** `Read` Access the Audit module and view created tables. **Create audit templates** `Write` Create new Audit tables in the Admin module of a building. **Delete audit templates** `Write` Delete Audit tables in the Admin module of a building. **Connectivity** **Get tunnels** `Read` Access the Connectivity module and view created tunnels. **Create tunnel** `Write` Create a tunnel in the Connectivity module. **Delete tunnel** `Write` Delete a tunnel in the Connectivity module. **Deployment Audit** **Get deployment audit reports** `Read` Access the Deployment Audit module. **Get deployment audit report details** `Read` Access the Deployment Audit report for a specific building. **Create deployment audit report** `Write` Create a Deployment Audit report for a specific building. **Energy Dashboard** **Get energy dashboard** `Read` Access the Energy Dashboard from the top main bar. **Marker Icons** **Get marker icons** `Read` View the categories of marker icons from the Admin panel. **Manage marker icons** `Write` Modify marker icons from the Admin panel. **Manage categories** `Write` Modify the categories of marker icons from the Admin panel. **Manage marker styles** `Write` Manage the styles of markers inside the edit mode of the graphics tool. **Dashboards** **Get dashboards** `Read` View the Dashboards module when navigating to a building. **Create dashboards** `Write` Create dashboards inside a building. **Delete dashboards** `Write` Delete dashboards inside a building. **Share widgets** `Write` Create a shareable link for a widget in a dashboard. ### Users Controls access to user management within the client organization. **General** **Get users** `Read` View the list of users in the Admin panel. **Assign buildings to users** `Write` Assign buildings to users in the Admin panel. **Create users** `Write` Create new users in the Admin panel. **Delete users** `Write` Delete users in the Admin panel. # Buildings Source: https://docs.kodelabs.com/products/launchpad/client-organizations/buildings Learn how to create and manage buildings in your organization portfolio The **Buildings** page, accessible from the left-hand sidebar, displays all buildings in your Launchpad workspace. It allows you to create new buildings and provides detailed controls for managing existing buildings, including building details, which products are enabled, and publish status. ![Buildings table showing building name, category, address, enabled products, timezone, square feet, and published status with search, filters, and Add Building controls](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-buildings-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=47f3dfa4d1abcef6736bcba33352781f) The Buildings page lists all buildings with name, category, address, enabled products, timezone, square feet, and status You can filter buildings by state, city, property type, enabled products, and status using the `Filters` panel. You can also export the building list as a CSV or bulk import buildings from a spreadsheet. ![Filters panel with dropdowns for state, city, property type, product enabled, and status, alongside export and bulk import options](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-buildings-filters.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=3bd6d4b29f12e173faa7f7677b90e1ea) The Filters panel and three-dot menu provide filtering, export, and bulk import options ## Create Buildings You can create buildings from the **Buildings** page using the `+Add Building` button. Follow the steps outlined below to create a new building. **1. Open the Buildings page** Once inside Launchpad, navigate to the **Buildings** page located on the left-hand sidebar. **2. Click +Add Building** Once inside **Buildings** click the `+Add Building` button to open the building creation form. **3. Configure building details** Configure the required details for the new building. The form includes General Information, Address Information, and Identifiers sections. ![Add Building form with fields for name, year constructed, area, type, floors, phone number, base temperature, unit, address, and identifiers](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-client-org-add-building-form.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=70eb55197f20e7b78ba99d7628a77ed2) The Add Building form collects general information, address, and identifier details **Example Configuration** | Field | Example Configuration | | - | - | | Name\* | `Headquarters` | | Year Constructed | `2015` | | Area\* | `50000` | | Type\* | `Office (choose from dropdown)` | | # of Floors | `12` | | Country Code | `United States +1` | | Phone Number | `+1 555 123 4567` | | Base Temperature\* | `65` | | Unit\* | `Fahrenheit` or `Celsius` | | Address\* | `225 Broadway, New York, New York, United States, 10007` | | Street\* | `Filled from Address` | | City\* | `Filled from Address` | | State | `Filled from Address` | | Country\* | `Filled from Address` | | Zip | `Filled from Address` | | Address Line 2 | `Suite 100 (optional)` | | Region | `Choose from dropdown` | | Brand | `Choose from dropdown` | | Zone | `North` | | District | `Downtown` | | Identifier | `BLDG-001` | | Site | `Choose from dropdown or add your own` | | Identifier | `Choose from dropdown or add your own` | **4. Save** Once you have configured the required building details, click `Save` to create the building. **5. Publish the building** New buildings default to **Unpublished**. Until you publish, access in KODE OS is limited to roles that can see unpublished buildings (for example, Super Admin). When the building is ready for broader access, click `Publish`, then confirm with `Yes, Publish`. You can also publish later from the building detail page. > [!WARNING] > > Creating and publishing a building is not enough for it to appear as expected in KODE OS. Your channel partner must [enable products](/products/launchpad/channel-partners/product-enablement) for that building from the channel Launchpad. A published building without enabled products may still be missing from KODE OS. > [!TIP] > > **Base Temperature** and its unit also feed weather-related widgets in Building BI. Set them to match the climate baseline you want those widgets to use. ## Manage Buildings The **Buildings** page lists all existing buildings in rows, with each row displaying key details about the respective building. Each building in your organization has a dedicated page that provides a centralized interface to view and manage all details related to that building. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph s1["Client Buildings"] B1["Building 1"] B2["Building 2"] B3["Building 3"] end A["Buildings Page"] -- view --- A1["Buildings Table"] A1 -- select ---- B1 B1 -- view & manage --- D1["Dedicated Page"] A1 -- select --- B2 & B3 B2 -- view & manage --- D2["Dedicated Page"] B3 -- view & manage --- D3["Dedicated Page"] linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00 ``` To manage a building, follow the steps outlined below: **1. Open the Buildings page** Once inside Launchpad, navigate to the **Buildings** page located on the left-hand sidebar. **2. Select a building** Select a building from the list. You will be redirected to its **dedicated** page. **3. Manage the building** Once inside the building's dedicated page, you can view general information, edit building details, and enable or disable products using the product toggle cards. ![Building detail page showing general information fields and product cards with toggle switches for Cloud BMS, FTT, FDD, OSS, BBI, AssetOps, Building Data Hub, EnerG, and Document Hub](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-building-detail.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=66b0638b70dad3e447d8156a65053ff5) A building's dedicated page shows general information and product toggle cards for enabling or disabling products You can complete the following actions: * Edit building details * Enable or disable products for the building * Manage publish status > [!NOTE] > > If you are a client organization, contact your KODE Labs representative to enable products for your buildings. Product enablement is managed by your channel partner through their Launchpad workspace. # Client Organizations Source: https://docs.kodelabs.com/products/launchpad/client-organizations/client-organization-overview Manage buildings, users, and service accounts A client organization is a client that and receives KODE OS products through its channel partner. In Launchpad, client organizations are primarily responsible for: * Adding and managing buildings in their portfolio * Adding and managing users who work on behalf of their organization * Managing applications and assigning users to KODE OS roles * Adding and managing service accounts * Configuring security settings * Setting up SSO * Managing the company profile The Home page provides an overview of your organization, including building count, user count, and total square footage. It also displays user security metrics, sign-in activity trends, and failed sign-in details. ![Client organization Home page with overview cards for buildings, users, and square feet, user security metrics, sign-in success and failure chart, and failed sign-ins table](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-home.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a663b6b2602546233730c083a1f42f2f) The client organization Home page shows portfolio metrics, user security status, sign-in activity, and failed sign-in details As a client organization, you access Launchpad via your dedicated workspace address in this format: ``` yourorganizationname.kodelabs.com ``` For workspace sign-in and activation, see [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ## Authentication logs The **Authentication Logs** page, accessible from the left-hand sidebar, records all sign-in activity for your organization. Each row in the table displays the user name, email, date and time, status, identity provider, message, IP address, and browser agent. ![Authentication Logs table showing columns for name, email, date and time, status, IDP, message, IP address, and agent, with search and filter controls](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-auth-logs-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a21fe3d22c7d6d2c47dbd719698b7ea8) The Authentication Logs page lists all sign-in attempts with status, IP address, and browser agent details Select a user from the table to view their individual authorization history. The detail page shows general information and a list of all authentication events for that user, including date, IP address, status, application, and agent. ![Authentication log detail page for a user showing general information and an authorizations table with date, IP address, status, application, message, and agent columns](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-auth-logs-detail.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=66fee7ea57321a65753d565dd1fdc228) A user's authentication detail page shows their general information and full authorization history ## Company profile The **Company Profile** page, accessible from the left-hand sidebar, displays your organization's core details. It includes three sections: General Information, Contact Person, and Preferences. Use the `Edit` button on each section to update the respective details. ![Company Profile page showing general information with name, access status, workspace domain, and address, contact person section with name, email, and phone number, and preferences section with default language](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-company-profile.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=52f4903669380fcfb5a80c322a012716) The Company Profile page displays general information, contact person, and language preferences for your organization ## Next steps Add and manage buildings, users, and service accounts for your organization. > [card] [User Management](/products/launchpad/client-organizations/users) > > Add users, invite from trusted organizations, and manage user details and app assignments. > [card] [Apps & Roles](/products/launchpad/client-organizations/apps) > > Define custom roles with per-product permissions and assign roles to users in your organization. > [card] [Building Management](/products/launchpad/client-organizations/buildings) > > Add buildings to your portfolio, update building details, and manage publish status. > [card] [Service Account](/products/launchpad/client-organizations/service-accounts) > > Create a service account for integrations and API access. # Service Accounts Source: https://docs.kodelabs.com/products/launchpad/client-organizations/service-accounts Learn how to create and manage service accounts for API and system integrations The **Service Accounts** page, accessible from the left-hand sidebar, lists all existing service accounts in rows, with each row displaying key information about the respective account. Selecting a service account opens a dedicated view for it, providing access to two sections: **Details** and **Permissions**. ## Details This section provides an overview of the service account and supports existing credential management. Use the **Details** section to: * View general information and details about the service account * Generate new credentials or add your own (for example, in JSON format) * Edit or disable existing credentials ![Service account detail page showing general information with email, created by, created at, credential type, client ID, and description, plus a Credentials section with a Generate Private Key button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-service-account-detail.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d052b9261f7807d6915f91df37aa903e) The service account Details section shows general information, credential type, and a prompt to generate a private key ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Service Accounts Table"] A1["Service Account A"] A2["Service Account B"] A3["Service Account C"] end subgraph s2["Account Sections"] D1["Details"] D2["Permissions"] end subgraph s3["Details"] P1["Account Info"] P2["Keys"] end A2 -- access --> D1 A2 --
      --- D2 D1 -- View & Manage --> P1 & P2 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:none,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none ``` ## Permissions This section allows you configure granular `Read` and `Write` permissions per resource so the service account has only the access it needs for its integration. Use the **Permissions** section to: * View and edit `Read` or `Write` access for each permission group * Scope access so integrations can only read or write the resources you allow Refer to the [permissions reference](/products/launchpad/client-organizations/service-accounts/permissions-reference) for more details. ![Service account Permissions page showing permission groups including BuildingsPublic, Actions, AreasPublic, DatasourcesPublic, DevicesPublic, MetersPublic, PointsPublic, SpacesPublic, TenantsPublic, TimeseriesPublic, and WorkOrdersPublic with green Read and orange Write permission badges](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-service-account-permissions.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=0f95bcd4b19e27d02b320d8ea91ebb22) The Permissions section lists permission groups with color-coded Read and Write access indicators ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral --- flowchart LR subgraph s1["Service Accounts Table"] A1["Service Account A"] A2["Service Account B"] A3["Service Account C"] end subgraph s2["Account Sections"] D1["Details"] D2["Permissions"] end subgraph s3["Permissions"] P1["General"] P2["Actions"] P3["AreasPublic"] P4["DatasourcesPublic"] P5["DevicesPublic"] P6["MetersPublic"] P7["PointsPublic"] P8["SpacesPublic"] P9["TenantsPublic"] P10["TimeseriesPublic"] P11["WorkOrdersPublic"] end A2 --
      ------ D1 A2 -- access ----- D2 D2 -- edit --- P1 & P2 & P3 & P4 & P5 & P6 & P7 & P8 & P9 & P10 & P11 linkStyle 0 stroke:none,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#FF6D00,fill:none linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00,fill:none linkStyle 7 stroke:#FF6D00,fill:none linkStyle 8 stroke:#FF6D00,fill:none linkStyle 9 stroke:#FF6D00,fill:none linkStyle 10 stroke:#FF6D00,fill:none linkStyle 11 stroke:#FF6D00,fill:none ``` ## Create a service account You can create a service account directly from the **Service Accounts** page using the `+Add Service` button. Follow the steps outlined below to create a new service account. > [!NOTE] > > You can manage a service account’s **details** and **permissions** once it has been created. **1. Open the Service Accounts page** Once inside Launchpad, navigate to the **Service Accounts** page located on the left-hand sidebar. **2. Click +Add Service** Once on **Service Accounts**, click the `+Add Service` button to create a new account. **3. Configure service account details** Complete the following fields for the new service account. The dialog provides fields for name, credential type, description, and site assignment. ![Add New Service Account dialog with fields for name, credential type selection between Private JWT and Client Secret, description, and site selection, displayed over the Service Accounts table](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-service-accounts-add.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d4429efd06c8d8079e2c734f0ca7409b) The Add New Service Account dialog collects name, credential type, description, and site assignment **Example Configuration** | Field | Example Configuration | | - | - | | Name | `BMS Integration` | | Credential Type | `Private Key (JWT)` or `Client Secret` | | Description | `Describe the Service Account purpose` | | Assign Sites(s) | `Select one or more buildings from your portfolio` | **4. Save** Once you have configured the required details, click **Save** to create the service account. **5. Generate credentials** After you create the service account, generate the credentials based on the credential type you selected. > [tab] Private Key (JWT) > > Select **Generate Private Key** on the service account detail page. Launchpad generates a key pair and downloads the private key file to your machine. > > > [!WARNING] > > > > The private key file downloads only once. Store it in a secure location immediately. If you lose the key, you must generate a new one and update your integration. > [tab] Client Secret > > Select **Generate Client Secret** on the service account detail page. Launchpad displays the secret value on screen. > > > [!WARNING] > > > > The client secret displays only once. Copy and store it in a secure location immediately. If you lose the secret, you must generate a new one and update your integration. ## Next steps Keep the service account credentials in your integration. Grant only the scopes the job needs. > [card] [Permissions reference](/products/launchpad/client-organizations/service-accounts/permissions-reference) > > Grant only the scopes your integration needs. # Permissions Reference Source: https://docs.kodelabs.com/products/launchpad/client-organizations/service-accounts/permissions-reference Reference for service account permission scopes and operations Each service account defines access through per-scope permissions. Permissions are classified as `Read` or `Write` and determine what the integration can do with each resource. After creating a service account, open its **Permissions** page to define access. Use the permissions reference below to see what scopes and operations are available. > [!NOTE] > > Enable only the permissions your integration requires. Granting broader access than necessary increases your security surface area. ### General Basic building information such as name, address, and configuration. **General** **Get Buildings** `Read` Retrieve basic building information such as name, address, and configuration details. ### Actions Building actions such as automated commands or system-level responses. **Actions** **Get Actions** `Read` Retrieve building actions, such as automated commands or system-level responses. ### AreasPublic Building areas such as floors, wings, or common spaces. **AreasPublic** **Get areas** `Read` Retrieve building areas, such as floors, wings, or common spaces. ### DatasourcesPublic Data source configurations such as BMS integrations or IoT gateways. **DatasourcesPublic** **Get Datasources** `Read` Retrieve data source configurations, such as BMS integrations or IoT gateways. ### DevicesPublic Devices such as controllers, sensors, or actuators connected through a data source. **DevicesPublic** **Get devices** `Read` Retrieve device data, such as controllers, sensors, or actuators connected through a data source. **Create Devices** `Write` Create new devices. ### MetersPublic Meters and meter assignments for energy or utility tracking. **MetersPublic** **Get meter** `Read` Retrieve a single meter. **List meters** `Read` Retrieve every meter in the building. **Create meter assignment** `Write` Assign a meter to a resource. **Create meter reference** `Write` Create a meter reference. **Delete meter** `Write` Remove a meter. **Delete meter assignment** `Write` Remove a meter assignment. **Delete meter reference** `Write` Remove a meter reference. **Update meter** `Write` Modify an existing meter. ### PointsPublic Data points such as temperature readings, set points, or equipment status values. **PointsPublic** **Get points** `Read` Retrieve data points, such as temperature readings, set points, or equipment status values. **Create Points** `Write` Create new data points. ### SpacesPublic Spaces and their meter associations within a building. **SpacesPublic** **Get space** `Read` Retrieve a single space. **Get space meters** `Read` Retrieve meter data for a space. **List spaces** `Read` Retrieve all spaces. **Batch create spaces** `Write` Create multiple spaces at once. **Batch update spaces** `Write` Update multiple spaces at once. **Create space** `Write` Create a single space. **Update space** `Write` Modify an existing space. ### TenantsPublic Tenants and tenant assignments for the building. **TenantsPublic** **Get tenant** `Read` Retrieve a single tenant. **Get tenant assignments** `Read` Retrieve tenant assignments. **List tenants** `Read` Retrieve all tenants. **Create tenant** `Write` Create a new tenant. **Delete tenant** `Write` Remove a tenant. **Update tenant** `Write` Modify an existing tenant. ### TimeseriesPublic Time-series data for trend analysis, reporting, and energy calculations. **TimeseriesPublic** **Get Timeseries** `Read` Retrieve time-series data for trend analysis, reporting, and energy calculations. **Create Timeseries** `Write` Write new time-series data. ### WorkOrdersPublic Work orders for maintenance tasks, repair requests, and scheduled activities. **WorkOrdersPublic** **Get WorkOrders** `Read` Retrieve work orders for maintenance tasks, repair requests, and scheduled activities. **Create WorkOrders** `Write` Create new work orders. # Users Source: https://docs.kodelabs.com/products/launchpad/client-organizations/users Learn how to create and manage client users The **Users** page, accessible from the left-hand sidebar, displays all users in your Launchpad workspace. It allows you to create new internal users directly, invite existing users from external organizations, and provides detailed controls for managing existing users regardless of origin. ![Users table showing columns for name, email, position, sign-in methods, type, role, status, created at, and MFA status, with search, filters, and Add User controls](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-users-table.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=e7a3e0ecdf6f9d649c410e76d1ea83f2) The Users page lists all users with name, email, position, sign-in methods, type, role, status, creation date, and MFA status > [!TIP] > > Organization administrators can add, invite, and assign users from this page. Use these controls when someone needs access to your workspace or apps. ## User Types In Launchpad, users are categorized as either **Internal Users** or **Guest Users**. These profiles define a user's type and determine what can be managed for a given user. * Internal users represent entities whose account and user profile both reside within the same organization. Internal users authenticate directly using the credentials and sign-in methods issued by your organization. * Guest users represent entities whose user profile resides in your organization while their account resides in a different (external) organization. They continue to authenticate using the credentials and sign-in methods issued by their parent organization. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: TB theme: neutral --- flowchart LR %% Your Organization subgraph OrgA["Organization A"] IU_Profile["Internal User Profile"] EU_Profile["External User Profile"] IU_Account["Account"] end %% External Organization subgraph OrgB["Organization B"] EU_Account["Account"] end %% Connections IU_Account -. connected ..- IU_Profile IU_Profile -. connected .- IU_Account EU_Account -. connected ....- EU_Profile EU_Profile -. connected .- EU_Account %% Labels / Classes classDef internal stroke:#FF6D00,fill:none; classDef external stroke:#00C853,fill:none; class IU_Account,IU_Profile internal; class EU_Account,EU_Profile external; ``` ## Create Users You can create or invite users from the **Users** page using the `+Add User` button. The dropdown menu provides two options: **Add User** for creating internal users and **Invite User** for inviting external guest users. ![Add User dropdown menu showing Add User option for internal users and Invite User option for external users](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-users-add-menu.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=7cf02cb4a38e3090ab1bdc7866e03b48) The Add User dropdown provides options to add an internal user or invite an external user > [tab] Add User > > Create a new internal user in this client organization. This creates a new account in the current organization. The user configures authentication with this organization's sign-in methods. > > The account setup email expires after 24 hours. Resend it from the user's three-dot menu. > > **1. Open the Users page** > > Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. > > **2. Click +Add User** > > Once inside **Users** click the `+Add User` button and select `Add User`. > > **3. Configure user details** > > Configure the required details for the new user. The form includes General Information, Active Sign In Methods, and Assign App sections. > > ![Add User form with fields for first name, last name, position, role, email, country code, phone number, account status toggle, access level, active sign-in methods, and KODE OS app assignment with role and site selection](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-client-org-add-user-form.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=4823d3dfd25fa933bc816068172d61f5) > > The Add User form collects general information, sign-in methods, and app assignment details > > **Example Configuration** > > | Field | Example Configuration | > | - | - | > | First Name | `Jane` | > | Last Name | `Smith` | > | Position | `Facilities Manager` | > | Role | `Admin`, `Restricted Access` | > | Email | `jane.smith@example.com` | > | Country Code | `United States +1` | > | Phone Number | `555 123 4567` | > | Account Status (Toggle on to create the account right away. Leave off to postpone creation.) | `Toggle On/Off` | > | Access Level | `Permanent or Temporary` | > | Active Sign-In Methods | `Choose Sign-In Method` | > > **4. Save** > > Once you have configured the required user details, click `Save` to create the user. > [tab] Invite User > > Invite an existing user from a trusted organization as a guest. > > > [!NOTE] > > > > You can invite a user only if they already exist as an **Internal** user in a trusted organization available to this environment. If they do not have that account, they will not receive the invite. > > The guest receives an invitation to join this client organization. They keep the authentication method from the organization where they are an internal user. > > The invitation stays open until they accept it or you delete the user. To send it again, delete the guest user and invite them again. Guests who have not accepted appear as `Pending`. > > **1. Open the Users page** > > Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. > > **2. Click +Add User** > > Once inside **Users** click the `+Add User` button and select `Invite User`. > > **3. Configure user details** > > Configure the required details for the invited user. The form includes General Information and Assign App sections. > > ![Invite User form with fields for trusted organizations, email, position, role, access level, and KODE OS app assignment with role and site selection](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-invite-user-form.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=10c3091379bae6c11fb0929d30b16e23) > > The Invite User form collects trusted organization, email, position, role, access level, and app assignment > > **Example Configuration** > > | Field | Example Configuration | > | - | - | > | Trusted Organizations (Select the trusted organization you will invite the user from) | `Acme Corp` | > | Email | `jane.smith@acme.com` | > | Position | `Facilities Manager` | > | Role | `Admin`, `Restricted Access` | > | Access Level | `Permanent or Temporary` | > > > [!NOTE] > > > > Sign-in methods are inherited from the parent organization and do not require configuration when inviting users. > > **4. Save** > > Once you have configured the required user details, click `Save` to invite the user. ### Assign Launchpad and KODE OS access Launchpad access and KODE OS access are independent. Assign both when the user needs them. Set the Launchpad role on the create or invite form. `Admin` grants Launchpad access in the client organization. `Restricted Access` keeps the user in the organization without Launchpad access. Assign the KODE OS app, a KODE OS role, and buildings on the form or after you save. Creating or inviting a user does not assign KODE OS by itself. If the user has no KODE OS assignment yet: 1. Open the user's record on the **Users** page. 2. Select `Assign App` next to **KODE OS**. 3. Choose a KODE OS role and assign the buildings they need. 4. Save the assignment. > [!NOTE] > > Creating a client adds you to that client with Launchpad Admin access only. Before you can use KODE OS in that client, open your own user record and assign the app the same way. Open the user record and assign KODE OS before that person tries to open the app. > [!TIP] > > Users who sign in successfully but see no KODE OS apps usually lack an app assignment. Open the user record, select `Assign App` next to **KODE OS**, then choose a role and buildings. ## Manage Users The **Users** page lists all existing users in rows, with each row displaying key details about the respective user. Each user in your organization, whether internal or external, has a dedicated user page that provides a centralized interface to view and manage all details related to a specific user. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph s1["Client Organization Users"] U1["User 1"] U2["User 2"] U3["User 3"] end A["Users Page"] -- view --- A1["Users Table"] A1 -- select ---- U1 U1 -- view & manage --- BIP1["Dedicated Page"] A1 -- select --- U2 & U3 U2 -- view & manage --- BIP2["Dedicated Page"] U3 -- view & manage --- BIP3["Dedicated Page"] linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#FF6D00,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none linkStyle 5 stroke:#FF6D00,fill:none linkStyle 6 stroke:#FF6D00 ``` To manage a user, follow the steps outlined below: **1. Open the Users page** Once inside Launchpad, navigate to the **Users** page located on the left-hand sidebar. **2. Select a user** Select a user from the list of users. You will be redirected to their **dedicated** page. **3. Manage the user** The user's dedicated page displays their general information, user type (Internal or Guest), and assigned apps. From here, you can edit details, manage their account, and control KODE OS access. ![User detail page showing general information with name, email, phone number, status, role, position, invited date, trusted organization, and access level, plus KODE OS app assignment with role and Edit Role and Unassign App buttons](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-user-detail.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5495e9220aaf721a48ddf40ec6336aad) A user's dedicated page shows general information, user type badge, and KODE OS assignment with role and management options You can complete the following actions: * Use the icon to edit user details. * Use the icon to manage the user, including deactivating or deleting them, changing their sign-in method, or resending the setup email. * Assign or remove assignment for `KODE OS` * Assign or change `KODE OS` role If a user cannot sign in after invite, confirm their sign-in method matches the workspace default (email password versus SSO). Updating the method on the user record resolves many login failures. > [!NOTE] > > You can change the sign-in method or resend the setup email for internal users only. A guest invitation stays open until the guest accepts it or you delete the user. To send a guest invitation again, delete that user and invite them again. # Accounts and Users Source: https://docs.kodelabs.com/products/launchpad/get-started/accounts-and-users Learn how accounts, profiles, and roles work Your account is your personal identity in Launchpad. A user profile is how that account appears within a specific organization, with its own role and permissions. Roles vary by organization and define what each user can view and do. ## Accounts and users Your **account** is your single identity across the entire platform. It stores login credentials, security settings, and personal preferences, and it belongs to your parent organization. Your **user profile** is different. It represents your presence within a specific organization and carries org-specific context such as your position, department, or role. Each organization you belong to has its own independent user profile for you, with its own role and permissions assigned by that organization. When you join a new organization, Launchpad creates a new user profile for you there. That profile is independent from the profile you hold in your parent organization. > [!NOTE] > > Regardless of how many organizations you belong to, every user profile connects back to your account in your parent organization. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph parentOrg["Parent Organization"] A["Account"] RP["User Profile"] end subgraph orgA["Org A"] UA["New User Profile in Org A"] end subgraph orgB["Org B"] UB["New User Profile in Org B"] end A -. Connected .-> RP RP -. Connected .-> A parentOrg -- invited to --> orgA & orgB linkStyle 0 stroke:#FF6D00,fill:none linkStyle 1 stroke:#FF6D00 linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none ``` ## Manage your account To access your account settings, select your profile icon in the upper-right corner of Launchpad and choose **Manage Account**. The account portal has four sections: **Organizations**, **Account**, **Activity**, and **Invitations**. ### Organizations The **Organizations** page lists every workspace tied to your account. Each organization appears as a card with its logo and name. Select **Open Organization** to enter that workspace. Use the search field to filter organizations by name. Toggle between **grid view** and **list view** using the icons in the upper-right corner of the page. If you belong to more than one organization, you can also switch instances from the profile menu or during sign-in. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in#organizations) for the full sign-in flow. ![Organizations page in the account portal showing organization cards with logos, names, and Open Organization buttons, plus search and grid or list view controls](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-organizations.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=0147e03892ec7146060492950cf0e689) The Organizations page lists all workspaces associated with your account, with an option to open each one ### Account The **Account** page displays your general information, including your name, email address, phone number, active sign-in methods, creation date, and default language. Click `Edit` to update your details. ![Account page showing General Information with user name, email address, phone number, active sign-in methods, created at date, created by, and default language fields with an Edit button](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-general-info.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=0435986d24578b3d141bd693473263a0) The Account page shows your general information including name, email, sign-in methods, and language preferences ### Activity The **Activity** section provides visibility into your sign-in history. It contains two subsections: Sessions and Login `IPs`. **Sessions** lists all active sessions grouped by device and browser, showing the number of sessions for each. ![Sessions page showing active sessions grouped by device including Chrome on Windows 10 with 61 sessions and Mobile Safari on iOS with 9 and 11 sessions](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-sessions.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=b0b813635544869860741497b9453278) The Sessions page groups active sessions by device and browser with session counts **Login `IPs`** displays all IP addresses used to sign in to your account, with first seen and last seen dates, frequency, and location. You can remove an IP address using the three-dot menu. ![Login IP addresses page showing address entries with first seen date, last seen date, frequency percentage, location, and a Remove option in the three-dot menu](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-login-ips.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=feed39f1bfc8a9d1961fdb412d45628d) The Login IP addresses page shows all addresses used to access your account with frequency and location details ### Invitations When another organization invites you, you receive an email with a `Review Invitation` button. A notification badge also appears on your profile icon and next to **Invitations** in the profile menu. ![KODE Labs invitation email showing the organization name, a Review Invitation button, and support contact information](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-invitation-email.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=4bc7ebc1d0538d122d0ad594ceaf0ca0) The invitation email identifies the organization and provides a Review Invitation button to accept or reject You can respond to invitations in two ways: * Click **Invitations** from the profile menu to open a popup where you can accept or reject pending invitations directly. ![Invitations popup dialog showing an invitation from a user to join an organization with the invitation date, and Reject and Accept buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-invitation-popup.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=a4051bb86468e3be84c93aa536ba24e5) The Invitations popup shows pending invitations with options to accept or reject each one * Open the **Invitations** page in the account portal to view all invitations in a full-page layout. ![Invitations page in the account portal showing a pending invitation with sender name, organization name, date, and Reject and Accept buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-invitations-page.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=794a1659893605f110b1af271102c9e0) The Invitations page in the account portal lists all pending invitations with sender, organization, date, and response options ## User roles User roles define what a user can view and do within **Launchpad**. Both channel partners and client organizations have their own set of Launchpad roles, with each role reflecting the different responsibilities each organization type carries. > [!NOTE] > > Roles apply whether you're adding a user directly or inviting one from a trusted organization. The organization extending the invitation always assigns the role—independent from the Launchpad role the user holds in their parent organization. For more, see [Trust settings](/products/launchpad/get-started/provisioning-architecture#trust-settings). > [tab] Channel partners > > **Admin** `Role` > > Full access to Launchpad. Admins can navigate all platform features, manage client organizations and their details, manage users, and configure SSO settings. > > **View Only** `Role` > > Read-only access to Launchpad. Users with this role can view client details, user information, and sign-in methods, but can't make changes. > > **Restricted** `Role` > > No access to Launchpad. Users with this role exist in the system and the channel partner can manage them centrally, but they can't log in to Launchpad. > [tab] Client organizations > > **Admin** `Role` > > Full access to the client organization's Launchpad. Admins can manage buildings, users, and settings within their organization. > > **Restricted Access** `Role` > > No access to Launchpad. Users with this role exist in the system but can't log in to Launchpad. # Configure Single Sign-On (SSO) Source: https://docs.kodelabs.com/products/launchpad/get-started/configure-single-sign-on-sso Set up SSO with OIDC or SAML SSO lets users sign in to Launchpad through their organization's identity provider instead of separate KODE Labs credentials. Launchpad supports OIDC and SAML, with pre-built integrations for several identity providers. You configure sign-in methods from **Sign In Methods** in the sidebar. ![Sign In Methods page showing Email and Password and Azure AD set as the default method, with an Add Sign in Method button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-sign-in-methods.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=3718f70c7031be1eb6625aa452e814df) The Sign In Methods page shows all configured methods, including Email & Password and any SSO integrations ## Benefits of Single Sign-On SSO simplifies the sign-in experience by eliminating the need to manage separate credentials for each platform. Users authenticate once through their organization's identity provider and gain access to Launchpad and other connected applications without repeated logins. This reduces password-related support requests and frees IT teams to focus on higher-priority work. * Centralized authentication through your existing identity provider * Reduced credential fatigue, as users rely on one set of credentials across platforms * Stronger security posture by enforcing your organization's authentication policies * Simplified user management, with user provisioning and de-provisioning handled through your IdP * Fewer password-related support tickets for IT teams ## Supported Sign-in Methods Launchpad supports SSO through the following authentication protocols. * **OpenID Connect (OIDC)** -- a modern authentication protocol commonly used for web and mobile applications. * **Security Assertion Markup Language (SAML)** -- an XML-based protocol widely adopted for enterprise SSO across web applications. KODE Labs has integrated with the following identity providers: * `CyberArk` * `Azure Active Directory (Azure AD)` * `Okta` * `Auth0` * `JumpCloud` > [!NOTE] > > You can also configure a custom OIDC or SAML integration with any IdP that supports these protocols. ## Configuration Setting up SSO requires configuring a sign-in method in Launchpad and connecting the corresponding application in your identity provider. You complete both from a single form in Launchpad. Click `+ Add Sign in Method` to choose a protocol or pre-built template. ![Choose Sign in Method dialog showing OIDC and SAML protocol options and pre-built templates for Auth0, Azure AD, Okta, CyberArk, and JumpCloud](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sign-in-add-method.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=ab9d47128d1e117fac2b4a6277caafd1) Choose between OIDC or SAML protocols, or select a pre-built template for Auth0, Azure AD, Okta, CyberArk, or JumpCloud > [!NOTE] > > Before you begin, verify that you have an admin role in your Launchpad workspace and access to your identity provider's configuration settings. > [tab] OIDC > > **1. Open sign-in methods** > > In the Launchpad sidebar, click **Sign In Methods**, then click **+ Add Sign in Method**. Select one of the pre-configured identity providers that uses OIDC, or choose a custom OIDC configuration if your provider is not listed. > > **2. Copy callback URL** > > Launchpad generates an **Authentication Callback URL** at the top of the form. Copy this value -- you need to enter it in your IdP as the Redirect URL or Callback URL. > > **Authentication Callback URL** `Field` > > The callback endpoint your IdP redirects users to after authentication. This value is auto-generated and read-only. > > **3. Name sign-in method** > > In the **Sign In Method Name** field, enter a unique name for this method. You can optionally upload an IdP picture. > > > [!WARNING] > > > > The sign-in method name cannot be changed after you save it. > > **4. Set up app in IdP** > > Log in to your identity provider and create a new application for KODE Labs. Provide the Authentication Callback URL you copied from Launchpad. After configuring the application, your IdP provides the values needed for the next step. > > **5. Enter IdP details** > > Back in the Launchpad form, enter the following values from your IdP: > > **OpenID Well-known URL** `Field` > > The OpenID Connect discovery endpoint provided by your IdP (typically ending in `/.well-known/openid-configuration`). > > **Client ID** `Field` > > The unique identifier your IdP assigned to the KODE Labs application. > > **Client Secret** `Field` > > The secret key your IdP generated for this application. > > **6. Configure email claim** > > Under **Claim configuration for email**, verify that the **Email** field is set to the claim your IdP uses for email addresses (defaults to `email`). > > **7. Save** > > Optionally check **Set as default Sign In Method** if you want this to be the primary sign-in option for your organization. Click **Save**. > [tab] SAML > > ![Add Sign-In Method form for SAML showing Assertion Consumer Service URL, SP Certificate download, sign-in method name field, SP Entity ID, SAML Subject NameID Format, Signature Algorithm, Protocol Binding, and Sign Request toggle](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sso-saml-form.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=35ed39fcd0203660b5ab359b017b85a4) > > The SAML configuration form shows generated values, sign-in method name, and pre-configured protocol fields > > **1. Open sign-in methods** > > In the Launchpad sidebar, click **Sign In Methods**, then click **+ Add Sign in Method**. Select one of the pre-configured identity providers that uses SAML, or choose a custom SAML configuration if your provider is not listed. > > **2. Copy generated values** > > Launchpad generates several values at the top of the form. Copy or download these -- you need them when configuring the application in your IdP. > > **Assertion Consumer Service URL** `Field` > > The endpoint where your IdP sends SAML responses after authentication. Copy this into your IdP's ACS URL field. > > **SP Certificate** `Field` > > The service provider certificate (`x509Certificate.pem`). Click **Download** to save it. > > **3. Name sign-in method** > > In the **Sign In Method Name** field, enter a unique name for this method. You can optionally upload an IdP picture. > > > [!WARNING] > > > > The sign-in method name cannot be changed after you save it. > > **4. Review pre-configured fields** > > The following fields are pre-configured in Launchpad and must match the corresponding values in your IdP: > > **SP Entity ID** `Field` > > The unique identifier for Launchpad as a service provider. > > **SAML Subject NameID Format** `Field` > > The format used to identify users. Pre-set to EmailAddress. > > **Signature Algorithm** `Field` > > The algorithm used to sign SAML assertions. Pre-set to RSA-SHA256. > > **Protocol Binding** `Field` > > The transport method for SAML messages. Pre-set to HTTP-POST. > > **Sign Request** `Toggle` > > When enabled, Launchpad signs outgoing SAML requests. Disabled by default. > > **5. Set up app in IdP** > > Log in to your identity provider and create a new application for KODE Labs. Provide the Assertion Consumer Service URL, SP Entity ID, NameID Format, Signature Algorithm, and Protocol Binding values from the Launchpad form. Configure attribute mapping in your IdP for `firstName`, `lastName`, and optionally `roles` to synchronize role assignments. > > **6. Enter IdP details** > > Back in the Launchpad form, you can either upload a metadata XML file to autofill the fields below, or enter them manually: > > **Upload MetaData** `Field` > > Upload your IdP's metadata XML file to autofill the IdP URL, IdP Entity ID, and Certificate fields. > > **IdP URL** `Field` > > The SSO endpoint provided by your IdP for SAML authentication. > > **IdP Entity ID** `Field` > > The unique identifier for your identity provider. > > **Certificate** `Field` > > The public certificate your IdP uses to sign SAML assertions. Upload a `.pem` or `.der` file. > > **7. Configure email claim** > > Under **Claim configuration for email**, enter the attribute your IdP uses for email addresses in the **Email** field. > > **8. Save** > > Optionally check **Set as default Sign In Method** if you want this to be the primary sign-in option for your organization. Click **Save**. ## Role mapping With SSO enabled, you can pass user roles from your identity provider to KODE OS automatically. This means user permissions are managed in your IdP rather than individually in Launchpad. Role mapping is optional -- you can always set user permissions directly in KODE OS regardless of how users authenticate. > [!NOTE] > > Role mapping requires attribute configuration in both your IdP and Launchpad. Before you configure role mappings, add the roles attribute in the Attribute Mappings section of your IdP and return the information in KODE Labs. To configure role mapping, open the sign-in method in Launchpad and configure the following options: **Create user on first login** `Toggle` Allows automatic user creation on first login. When enabled, configure the `First Name` attribute, `Last Name` attribute, and `Roles` attribute that your IdP returns. **Default Role** `Toggle` Sets a fallback role for users who do not have a role mapped in this sign-in method. You can add additional roles after you save the sign-in method. **Update user role on login** `Toggle` When enabled, existing roles assigned to users in Launchpad are overridden by the roles assigned to their IdP groups on each login. **Site Mapping** `Toggle` When enabled, allows access to the site map. You can add additional site mappings after you save the sign-in method. > [!NOTE] > > After you enable IdP role mapping, role management for users of that IdP is handled from your IdP instead of from Launchpad. You can manage your role mappings by adding the ability to create, update, and assign users to buildings on sign-in. ### Attribute mapping Under Attribute Mapping in your IdP, add the following attributes. If you want to map IdP groups or roles to KODE OS roles, add a `roles` attribute and return your IdP users' roles or groups to Launchpad. * **SAML IdP**: `firstName` attribute, `lastName` attribute, `roles` attribute * **OIDC IdP**: `firstName` claim, `lastName` claim, `roles` claim ## Edit SSO configuration To update an existing SSO configuration: **1. Open the sign-in method** In the Launchpad sidebar, click **Sign In Methods**. Select the method you want to modify. **2. Edit the configuration** Click `Edit` at the top-right of the SSO Details section. Update the configuration or attribute fields as needed, such as `SP Entity ID`, `IdP URL`, or `IdP Entity ID`. **3. Update metadata or certificate** You can upload a new metadata file to autofill the required fields, or update the signing certificate manually. **4. Save** Click `Save` to apply the changes. Click `Cancel` to discard them. ## Sign in with SSO Once SSO is configured, users can sign in through their organization's identity provider. There are two ways to access your workspace. ### With a workspace URL If you know your workspace URL, enter it directly in your browser (for example, `companyname.kodelabs.com`). The sign-in page displays your configured SSO options alongside the standard email and password login. ![Sign In to KODE Labs page showing Sign in with Azure AD button, email and password fields, and an Other sign in methods option](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sso-sign-in-page.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=fd3b55398829c0384a3fae9e9de3c2c6) The sign-in page shows SSO options alongside email and password login You can sign in using one of the following options: * Click a **Sign in with...** button to authenticate through your IdP. If you are already signed in to your IdP, you are redirected to your workspace without additional prompts. Otherwise, you are redirected to your IdP's sign-in page first. * Enter your email and password and click `Login with Email` to use your KODE OS credentials. > [!TIP] > > Azure AD errors such as `AADSTS50020` usually mean the account is not in your organization directory. Personal Microsoft accounts (for example, `@gmail.com` via `live.com`) cannot use Azure AD alone. Ask your organization's IT team to add the user as a guest in Azure AD, or sign in with the method your Launchpad administrator assigned. ### Without a workspace URL If you do not know your workspace URL, navigate to `accounts.kodelabs.com`. Enter your workspace domain and click `Continue` to reach your sign-in page. ![Sign in to your workspace page with a workspace domain field showing the .kodelabs.com suffix and a Continue button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sso-workspace-domain.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=431d92997e523b75ea8a9944c6f82f7c) The workspace domain page lets you enter your organization's subdomain to access the sign-in page ### Find your workspace If you do not know your workspace domain, click **Find your workspaces** on the workspace domain page. Enter your KODE OS account email and click `Continue`. You receive an email with instructions to locate your workspace. ![Find your workspace page with an email field and Continue button, plus a link to return to the workspace sign-in page](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sso-find-workspace.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=602123e5fda2f9f8e5b58d4346c94a11) The Find your workspace page sends workspace details to your email address # What's Launchpad? Source: https://docs.kodelabs.com/products/launchpad/get-started/introduction Central management hub for the KODE ecosystem Launchpad is the central management hub for the KODE ecosystem. From it, you provision products, control access, and assign roles across your organization and the organizations you serve. ## Who uses Launchpad Launchpad serves two organization types. Each type has its own workspace, landing-page apps, and admin scope. * A channel partner (A reseller that delivers KODE products to customer organizations. Channel partners create clients, enable products for buildings, and manage their own internal users.) sits above one or more clients in the hierarchy. * A client organization (A customer organization that manages buildings and users. Clients receive KODE products through their channel partner and work in KODE OS at the building level.) manages buildings, users, and KODE OS access for its portfolio. Use the tabs below to compare what each organization type does in Launchpad. > [tab] Channel partners > > A **channel partner** is a reseller that delivers KODE products to client organizations. Channel partners work in a channel Launchpad workspace. The landing page typically shows **Channel Management** only. > > In Launchpad, channel partners: > > * Create and manage client organizations > * Activate KODE OS for clients > * Enable products for buildings under those clients > * Add and manage users who work on behalf of the channel partner > > Buildings are not created from the channel workspace. Create buildings in the client Launchpad, then return to the channel to enable products. > > > [card] [Channel partner overview](/products/launchpad/channel-partners/channel-partner-overview) > > > > Manage clients, product enablement, and channel users. > [tab] Client organizations > > A **client organization** manages a portfolio of buildings and receives KODE products through its channel partner. Clients work in a client Launchpad workspace. The landing page typically shows **Client Management** and, when assigned, **KODE OS**. > > In Launchpad, client organizations: > > * Add and manage buildings in their portfolio > * Publish buildings when they are ready for broader KODE OS access > * Add and manage users and service accounts > * Assign the KODE OS app, roles, and buildings to users > > Product enablement for buildings is controlled by the channel partner. A published building without enabled products may still not appear as expected in KODE OS. > > > [card] [Client organization overview](/products/launchpad/client-organizations/client-organization-overview) > > > > Manage buildings, users, apps, and service accounts. ## Next steps Explore the guides below to get started. > [card] [Provisioning architecture](/products/launchpad/get-started/provisioning-architecture) > > Understand the hierarchical structures behind Launchpad and how channel partners and client organizations relate. > [card] [Accounts and users](/products/launchpad/get-started/accounts-and-users) > > Learn how accounts, user profiles, and roles work across organizations. > [card] [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in) > > Sign in, open applications from the landing page, and configure MFA and passwords. > [card] [Configure SSO](/products/launchpad/get-started/configure-single-sign-on-sso) > > Set up single sign-on with OIDC or SAML and connect your identity provider. > [card] [Security settings](/products/launchpad/get-started/security-settings) > > Configure MFA, password policies, lockout behavior, and session timeouts. # Provisioning Architecture Source: https://docs.kodelabs.com/products/launchpad/get-started/provisioning-architecture Understand the hierarchical provisioning structure across organizations Launchpad provisioning follows a three-tier structure, where each tier manages the one below it. Organizations operate strictly within their tier, while trust settings enable controlled access across tiers without requiring separate credentials. ## Provisioning Hierarchy Provisioning in Launchpad follows a strict top-down hierarchy. Each tier holds authority over the one below it, and access always originates from a higher tier before a lower tier can use it. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph s1["Building Portfolio"] D1["Building 1"] D2["Building 2"] end subgraph s2["Building Portfolio"] D3["Building 1"] D4["Building 2"] end subgraph s3["Building Portfolio"] D5["Building 1"] D6["Building 2"] end subgraph s4["Building Portfolio"] D7["Building 1"] D8["Building 2"] end A["KODE"] -- Provisioned by KODE --> B1["Channel Partner 2"] & B2["Channel Partner 1"] B1 -- Provisioned by CHP --> C1["Client Org B"] & C2["Client Org A"] C1 -- Manage --> D1 & D2 C2 -- Manage --> D3 & D4 B2 -- Provisioned by CHP --> C3["Client Org B"] & C4["Client Org A"] C3 -- Manage --> D5 & D6 C4 -- Manage --> D7 & D8 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#FF6D00,fill:none linkStyle 5 stroke:#FF6D00 linkStyle 6 stroke:#FF6D00,fill:none linkStyle 7 stroke:#FF6D00,fill:none linkStyle 8 stroke:#00C853,fill:none linkStyle 9 stroke:#00C853,fill:none linkStyle 10 stroke:#FF6D00,fill:none linkStyle 11 stroke:#FF6D00,fill:none linkStyle 12 stroke:#FF6D00,fill:none linkStyle 13 stroke:#FF6D00,fill:none ``` ### Platform Tier KODE sits at the top of the hierarchy and is the sole entity that provisions channel partners. During this process, KODE grants the channel partner access to Launchpad and enables the KODE OS products they have requested. No other entity can create or modify a channel partner's access. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart TB A["KODE"] -- Provisioned by KODE ---> B1["Channel Partner 1"] & B2["Channel Partner 2"] & B3["Channel Partner 3"] & B4["Channel Partner 4"] linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853 ``` ### Channel Partner Tier Channel partners provision client organizations and control which KODE OS products each client can access, based on the terms of their agreement. A channel partner can provision any number of clients and manage their entire portfolio of clients directly from Launchpad. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart TB subgraph CHP2Clients["Clients"] C1["Client Org A"] C2["Client Org B"] end subgraph CHP1Clients["Clients"] C3["Client Org A"] C4["Client Org B"] end B1["Channel Partner 2"] -- Provisioned BY CHP2 --> C1 & C2 B2["Channel Partner 1"] -- Provisioned BY CHP1 --> C3 & C4 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853 linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none ``` ### Client Organization Tier Once provisioned by a channel partner, a client organization operates independently within its own Launchpad environment. It adds buildings to its portfolio, manages its users, and creates KODE OS roles, requiring channel partner involvement only for product enablement. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart TB subgraph s1["Building Portfolio"] D1["Building 1"] D2["Building 2"] end subgraph s2["Building Portfolio"] D3["Building 1"] D4["Building 2"] end C1["Client Org B"] -- Manage --> D1 & D2 C2["Client Org A"] -- Manage --> D3 & D4 linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853 linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none ``` ## Trust Settings Trust settings allow organizations to invite users from another organization. When one organization trusts another, the trusted organization can invite users. By default, trust is one-way and does not provide reciprocity. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: layout: dagre theme: neutral --- flowchart LR subgraph chp["Channel partner"] U[Users] end subgraph clients["Client organizations"] C1[Client Org A] C2[Client Org B] end C1 -- One-Way Trust ------- chp C2 -- One-Way Trust --------- chp C1 -.->|Invite| U C2 -.->|Invite| U linkStyle 0,1 stroke:#22c55e ``` For more on how users and roles work across organizations, see [Accounts and users](/products/launchpad/get-started/accounts-and-users). # Security Settings Source: https://docs.kodelabs.com/products/launchpad/get-started/security-settings Configure MFA, password policies, and session timeouts Security settings give administrators control over authentication, password policies, and session behavior. All configuration lives under `Security Settings`. ## Configuration Authentication & Security covers three areas—MFA, Password, and Timeout Settings. Each area groups related controls that you can configure independently. > [tab] MFA > > Multi-factor authentication (MFA) adds a second layer of verification beyond a password. You can choose whether to enforce MFA for your organization and configure how frequently users verify their identity. > > ![MFA settings showing enforcement options and frequency choices including every login, 7-day remember, and 30-day remember](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-security-mfa.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=8ae8e807fff61e7c869d219474d52478) > > The MFA tab controls enforcement and frequency options for multi-factor authentication > > ### Enforcement > > **Don't enforce** `Option` > > MFA is optional for all users. > > **Enforce for Email & Password users** `Option` > > Requires MFA for all users who sign in with an email address and password. SSO users follow their identity provider's MFA policies. > > ### Frequency Options > > Select which frequency options are available to users. Users choose how often they're prompted for MFA during login based on the options you enable. > > **Every login** `Toggle` > > Users verify their identity on every login. Highest level of security. > > **Remember 7 days on known device** `Toggle` > > Users aren't prompted for MFA again for 7 days on a recognized device. > > **Remember 30 days on known device** `Toggle` > > Users aren't prompted for MFA again for 30 days on a recognized device. > [tab] Password > > Password settings let you define complexity requirements, configure lockout behavior after failed login attempts, and set additional password management rules. > > ![Password settings showing Medium complexity selected with requirements, lockout settings of 1 hour and 3 retries, and password history and expiration toggles](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-security-password.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=4a1e0ed98ae62124dadb3036d89b163c) > > The Password tab covers complexity levels, lockout settings, and password history configuration > > ### Password Complexity > > **Medium** `Option` > > Passwords must be at least 8 characters and include 1 digit, 1 uppercase letter, 1 lowercase letter, and 1 special character. KODE also rejects commonly used passwords. > > **High** `Option` > > Passwords must be at least 12 characters and include 1 digit, 1 uppercase letter, 1 lowercase letter, and 1 special character. High complexity also disallows consecutive characters. > > **Custom** `Option` > > Define your own complexity rules to match your organization's security policies. Custom rules can include lowercase requirements and non-consecutive character rules. > > ### Lockout Settings > > **Lockout time** `Field` > > How long an account stays locked after reaching the maximum failed login attempts. Defaults to `1`. > > **Lockout unit** `Field` > > The unit of time for the lockout duration. Defaults to `Hours`. > > **Retries before lockout** `Field` > > The number of failed login attempts allowed before the account locks. Defaults to `3`. > > ### Password Configuration > > **Password history** `Toggle` > > When enabled, users can't reuse recent passwords. > > **Password expire time** `Toggle` > > When enabled, passwords expire after a set number of days. Defaults to `90` days. > [tab] Timeout Settings > > Timeout settings control how long user sessions remain active before requiring sign-in again. > > ![Timeout settings showing session timeout of 14 days and idle timeout of 1 day](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-client-org-security-timeout.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=2743bbf68cbbd0e6f2760272c14ba0c7) > > The Timeout Settings tab configures session and idle timeout durations > > **Session Timeout** `Field` > > How long a session can stay active before the user is automatically signed out. Defaults to `14` days. > > **Idle Timeout** `Field` > > How long a session can stay idle before it's automatically terminated. Defaults to `1` day. # Workspaces & Sign-In Source: https://docs.kodelabs.com/products/launchpad/get-started/workspaces-and-sign-in Sign in to Launchpad, manage your account and organizations, open applications from the landing page, and configure authentication Every user accesses Launchpad through a workspace, a dedicated environment tied to their organization. This page covers sign-in, the Launchpad landing page, account activation, password management, and multi-factor authentication (MFA). ## Account activation How you activate access depends on whether you are a new internal user or an invited guest. ### New internal user An administrator creates your account in the organization. You receive account setup information and configure authentication with that organization's sign-in methods. You may set a password, complete multi-factor authentication (MFA), or sign in with single sign-on (SSO). The method follows the organization's security settings. #### Email and password When the organization uses email and password, the setup email includes `Set Password`. The link expires after 24 hours. **1. Open the setup email** Locate the setup email in your inbox and click `Set Password`. ![KODE OS welcome email showing organization name, granted app access to Launchpad, email address, sign-in methods, support contact, and Google Play and App Store download links](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-activation-email.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=b564e18e4715767b737e9e578284c623) The welcome email confirms your organization, app access, sign-in methods, and provides mobile app download links **2. Set password** Enter a password that meets your organization's security requirements, then confirm it by entering it a second time. Accept the privacy policy, then click `Set Password` to complete activation. KODE rejects commonly used passwords even when they meet complexity rules. Your organization may also enforce Medium, High, or Custom complexity in [Security settings](/products/launchpad/get-started/security-settings). ![Setup Password page with Enter Password and Confirm Password fields and a Set Password button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-setup-password.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5c5c9263b6efe34ed0a5a7865eb6c2eb) The Setup Password page prompts you to enter and confirm your new password **3. Complete activation** Click **Save** to finalize your account setup. You can now sign in to your workspace. > [!NOTE] > > If the setup link has expired, go to your workspace sign-in page, select **Forgot Password**, and enter your email address to receive a new reset link. The reset link expires after one hour. > > ![Password reset email from The KODE OS Team with a Reset Password button and a note that the request expires in one hour](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-reset-password-email.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=ff3441e7c3930dd59989111d011c26ad) > > The password reset email contains a Reset Password button that expires after one hour #### Single sign-on When the welcome email lists an SSO method such as Azure AD, sign in with that identity provider button. A separate password email is not part of SSO setup. ### Invited guest user A guest already has an account in a trusted organization. You receive an invitation to join an additional organization. You keep the authentication from the organization where your account is internal. Open the email and select `Review Invitation`. Accept the invitation to join. You continue with the sign-in method, MFA, and security settings from that existing account. See [Invitations](/products/launchpad/get-started/accounts-and-users#invitations) to accept or reject an invitation from your account. ## Sign in and authentication Sign in to Launchpad using a link provided by KODE Labs or your channel partner. ### Launchpad access URL Your workspace uses a dedicated address in this format: ``` {your-company-name}.kodelabs.com ``` Replace `{your-company-name}` with your organization subdomain (for example, `zenestate.kodelabs.com`). > [!NOTE] > > Contact your administrator if you do not know your Launchpad access URL. ### Sign in to your workspace **1. Open your Launchpad URL** Open your workspace address in a browser. The sign-in screen appears. **2. Enter credentials** Enter your username (email address) and password. **3. Open Launchpad** Select **Login with Email**. If you belong to more than one organization, select the instance you want after sign-in. The [Launchpad landing page](#launchpad-landing-page) loads when authentication succeeds. ![Sign-in page showing SSO options, email and password fields, and Forgot password link, alongside the Forgot Password page with an email field and Reset Password button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-sign-in-forgot-password.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=9b02bce1ab50699695d468414ca6b08d) The sign-in page includes a Forgot password link, and the Forgot Password page prompts for your email to receive a reset link If you belong to two or more organizations, Launchpad prompts you to choose an organization after sign-in. You can also switch organizations from the [Organizations](#organizations) page in the account portal. That switch works when your account is internal in one organization and a guest in the others. If your account is internal in more than one organization, sign out and sign in again before you switch. Staying signed in can cause sign-in conflicts. > [!TIP] > > If email and password fail after an invite, check your active sign-in method with an administrator. Many workspaces require Azure AD or another SSO option instead of a KODE password. ### Multi-factor authentication (MFA) Launchpad supports an additional sign-in verification step through MFA. You can enable MFA for your account from **Manage Account** in the profile menu using **Text message (SMS)** or a **third-party authenticator** app. See [Enable 2FA](#enable-2fa). Organization administrators can enforce MFA and set frequency rules in [Security settings](/products/launchpad/get-started/security-settings). *** ## Launchpad landing page After you sign in, the Launchpad landing page lists the applications you can open. This view is your central entry point to KODE products. It does not control permissions; access to each product still follows your assigned roles. ![Launchpad landing page showing Welcome message, current organization name, and Quick Access to Apps list with Client Management KODE OS AssetOps and EnerG](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-landing-page.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=bc05593f3a9ab561efc63a93636c4ea0) Launchpad landing page with Quick Access to Apps and Open App actions The page shows which organization you are working in (for example, **ZEN Estate**) and a **Quick access to apps** list. ### Channel vs client landing page Use the apps list to confirm which Launchpad level you are in: | Level | Apps you typically see | | - | - | | **Channel partner** | **Channel Management** only | | **Client organization** | **Client Management** and, when assigned, **KODE OS** | If you see **KODE OS** on the landing page, you are in a client workspace. Buildings are created in the client environment. Product enablement for those buildings is managed from the [channel partner](/products/launchpad/channel-partners/product-enablement) workspace. ### Application list The landing page shows applications you are allowed to open. Your list depends on product enablement and your permissions. Common applications include: | Application | Description | | - | - | | **Channel Management** | Launchpad administration for channel partners (clients, channel users, product enablement) | | **Client Management** | Launchpad administration for client organizations (buildings, users, apps) | | **KODE OS** | Cloud-based smart building operating system | | **AssetOps** | Asset and maintenance operations | | **myMSI** | Legacy MSI project and device linking workflows | | **EnerG** | Energy planning and sustainability (when enabled for your organization) | You only see applications you have access to. ### Open an application **1. Find the application** Locate the product you need in **Quick access to apps** (for example, **AssetOps**). **2. Select Open App** Select **Open App** on the right side of the application row. The product opens in your browser. ### Direct navigation **Open App** takes you directly into the selected product environment. Launchpad acts as navigation only; it does not gate permissions inside each product. | Application | Example path after **Open App** | | - | - | | **AssetOps** | `{your-company-name}.kodelabs.com/bms/maintenance` | Replace `{your-company-name}` with your organization subdomain. Other products use their own paths under the same domain. > [!NOTE] > > Access to each application is managed by existing user permissions in that product. The landing page is a navigation hub, not the access control layer. > [!TIP] > > If **Quick access to apps** is empty after sign-in, ask an administrator to assign the KODE OS app, a role, and buildings on your user record. A Launchpad Admin role manages Launchpad only. It does not grant KODE OS access by itself. *** ## Workspaces A workspace is a dedicated Launchpad environment assigned to your organization. It serves as the central location where you manage users, applications, settings, and all other resources tied to that organization. You receive your workspace address during provisioning. Use the [sign-in steps](#sign-in-to-your-workspace) above to open it. ## Manage your account To access your account settings, select your profile icon in the upper-right corner of Launchpad and choose **Manage Account**. The account portal has four sections: **Organizations**, **Account**, **Activity**, and **Invitations**. ![Profile dropdown menu showing user name and email, with options for Edit Profile, Manage Account, Switch Organization, Invitations, and Logout](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-profile-menu.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=142a7a07c347ebcf40a909c6bf2e54f8) The profile menu provides access to profile editing, account management, organization switching, invitations, and sign out For account details, sign-in history, and invitations, see [Accounts and users](/products/launchpad/get-started/accounts-and-users#manage-your-account). ### Organizations The **Organizations** page lists every workspace tied to your account. Use it after sign-in or when you need to switch to another organization. Each organization appears as a card with its logo and name. Select **Open Organization** on a card to enter that workspace and return to the Launchpad landing page for that instance. Use the search field to filter organizations by name. Toggle between **grid view** and **list view** using the icons in the upper-right corner of the page. ![Organizations page in the account portal showing organization cards with logos, names, and Open Organization buttons, plus search and grid or list view controls](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-organizations.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=0147e03892ec7146060492950cf0e689) The Organizations page lists all workspaces associated with your account, with an option to open each one ### Password procedures Use the appropriate process below depending on whether you've forgotten your password or want to update it while signed in. > [tab] Forgot password > > Use this process if you can't remember your current password and need to create a new one. > > **1. Open sign-in page** > > Navigate to your [Launchpad access URL](#launchpad-access-url) in a browser. Select **Forgot password?** below the password field. The Forgot Password page appears. > > **2. Request reset link** > > Enter your email address and click `Reset Password`. You receive an email with a reset link. > > **3. Reset password** > > Open the password reset email, click `Reset Password`, and set a new password. After saving, return to the sign-in page and log in with your updated credentials. > [tab] Change password > > Use this process to change your password while you are already signed in. > > **1. Open Manage Account** > > Click your profile icon in the upper-right corner of Launchpad and select **Manage Account**. > > ![Profile dropdown menu with Manage Account option highlighted](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/launchpad/launchpad-profile-menu-manage.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=9167cae35184038bbd2c22a77574c13f) > > Select Manage Account from the profile menu to access your account settings > > **2. Edit password** > > On the Account page, locate the **Password** section and click `Edit`. The Change Password dialog appears. > > ![Account page showing General Information with user name, email, phone number, active sign-in methods, and creation date, Password section with Reset at date, and Two-factor authentication section with Authenticator App and Text Message options](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-account-page-full.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=4da4588d9809b0dc7cacd2455b6f4a1b) > > The Account page shows General Information, Password section, and Two-factor authentication options > > **3. Change password** > > Enter your old password, then enter and confirm your new password. Click `Save`. > > ![Change Password dialog with Old Password, New Password, and Confirm New Password fields, plus Cancel and Save buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-change-password-dialog.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=9400ab52197f3072e64291bd39f0f690) > > The Change Password dialog prompts for your old password, new password, and confirmation ### Enable 2FA Multi-factor authentication (MFA) adds an extra layer of security to your account by requiring a second verification step in addition to your password. Even if someone obtains your password, they cannot access your account without this second factor. Launchpad supports two methods: Authenticator App and SMS. > [tab] Authenticator App > > The Authenticator App method generates time-based one-time codes using a mobile app such as Google Authenticator, Microsoft Authenticator, or Authy. These codes refresh every 30 seconds and do not rely on mobile network availability. > > **1. Open Manage Account** > > Click your profile icon in the upper-right corner of Launchpad and select **Manage Account**. > > ![Profile dropdown menu with Manage Account option highlighted](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-2fa-manage-account.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=a711f9b7717550be7cebf27b12168ee7) > > Select Manage Account from the profile menu to access your account settings > > **2. Select Authenticator App** > > On the Account page, locate the **Two-factor authentication** section and click **Authenticator App**. > > ![Account page with Two-factor authentication section showing Authenticator App marked as Recommended and Text Message SMS option](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-2fa-authenticator-select.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=d5cd5d63a2c840500451208be26cb187) > > The Account page shows the Two-factor authentication section with Authenticator App and Text Message options > > **3. Scan the QR code** > > Open your authenticator app on your phone (Google Authenticator, Microsoft Authenticator, Authy, or similar). Scan the QR code displayed on screen, or enter the setup key manually if your app supports it. > > **4. Enter the code and enable** > > Enter the current 6-digit code from your authenticator app and click `Enable`. > > ![Enable Authenticator App dialog showing a QR code, a manual setup key, and a field to enter the 6-digit code with Cancel and Enable buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-2fa-authenticator-setup.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=84e3ca3aad5607c91e7e163f29e00644) > > The Enable Authenticator App dialog displays a QR code, setup key, and a field to enter the 6-digit verification code > > Once enabled, you enter a new code from the app each time you sign in. > [tab] Text Message (SMS) > > SMS authentication sends a one-time verification code to your registered mobile number each time you sign in. This method is convenient but depends on mobile network access. > > **1. Open Manage Account** > > Click your profile icon in the upper-right corner of Launchpad and select **Manage Account**. > > **2. Select Text Message (SMS)** > > On the Account page, locate the **Two-factor authentication** section and click **Text Message (SMS)**. > > ![Account page with Two-factor authentication section showing Text Message SMS option highlighted](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-2fa-sms-select.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=a72c001be53ebcf7d8be038a29aea528) > > The Account page shows the Two-factor authentication section with Text Message SMS highlighted > > **3. Enter phone number and get code** > > Select your **Country Code**, enter your **Phone Number**, and click `Get Code`. > > ![Enable Text Message SMS dialog showing country code dropdown, phone number field, and Get Code button with Cancel and Enable buttons](https://mintcdn.com/kodelabs/IqRYtNzjTvsoxL_7/images/launchpad/launchpad-2fa-sms-setup.png?fit=max\&auto=format\&n=IqRYtNzjTvsoxL_7\&q=85\&s=3031ec26dcedfd47c665d99fa07a6446) > > The Enable Text Message dialog prompts for your phone number and sends a verification code via SMS > > **4. Enter the code and enable** > > Check your phone for an SMS containing a 6-digit verification code. Enter the code in the field and click `Enable`. Two-factor authentication is now active for your account. # KODE glossary Source: https://docs.kodelabs.com/products/launchpad/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Trends on mobile Source: https://docs.kodelabs.com/products/mobile-app/analytics/trends Select source forms, chart points in Trends View, apply filters, and save views on the KODE OS mobile app. Chart a point's recent history to spot a drift before it becomes a fault. Pick one or more points, then open `Trends View` for synchronized charts. Adjust the time range and interpolation, and save the view for yourself or your building team. This page follows [Trends](/products/kode-os/trends) on the web. ## Open Trends Reach `Trends` from the building app launcher, equipment menus, system points, or search when enabled. ## Select points to chart The `Trends` home screen lists point entries. Each row shows the point name with the device name below and a label for the device origin—virtual or original. ![Trends point list with device names below each point and virtual or original origin labels](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trends-source-list.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=65f3003ab825e45cdb3547ccbe9edaa8) | Element | Description | | - | - | | Point row | Point name with device name on the line below | | Virtual / Original | Whether the device origin is virtual or original | | Checkbox | Include the series in the next chart | | Filter icon | Open [Trend filters](#apply-trend-filters) | | Search/history icon | Find recent or saved selections | | Footer control | Action | | - | - | | `Cancel` | Clear selection and stay on the list | | `Trends View` | Open charts for selected series | ## Apply trend filters Tap the filter icon on the Trends list to narrow which points appear before you select them. ![Trend Filters with Area, Type AHU, Point Field, and Device fields](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trend-filters.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=1c8f5872cf2176f3741e25e1fa488a63) | Field | Description | | - | - | | `Area` | Floor or zone | | `Type` | Equipment ontology (for example, `AHU`) | | `Point Field` | Signal template (discharge air temp, fan status, and so on) | | `Device` | Specific equipment instance | Use `Clear All`, then `Apply` to refresh the list. ## Trends View Select the points you want to trend from the [Trends home screen](#select-points-to-chart), then tap `Trends View` on the bottom bar. `Trends View` shows stacked charts that share one time axis. Numeric series appear on the top chart; boolean or state series appear on the lower chart. ### Header controls | Control | Purpose | | - | - | | Back | Return to source selection | | `Save View` | Name and optionally publish the current chart setup | | Interpolation | Smooth between samples when `On` | | Time range | Preset or custom window (dropdown) | ![Trends View with numeric and AHU\_1 fan state chart for Yesterday](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trends-view-yesterday.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=9c13758a3e37bdad4f1cf5c46ead8a89) Yesterday with interpolation on ### Legend and pagination Below the controls, `Left Axis` lists active series (for example, `AHU_1, NumericSwitch` and `AI`). Use `1/2` arrows when more series exist than fit on screen. ### Numeric chart * Y-axis shows engineering values (for example, 7.5–9.6) * Multiple series may render as dense bands when sampling is fast * Pinch or use the bottom range slider to pan and zoom time ![Trends View for Last 2 Days with May 27 and May 28 on the axis](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trends-view-last-2-days.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=93333050a0c01931153f7fce6243d6be) Last 2 Days spans multiple dates on the X-axis ### State / boolean chart The lower chart shows boolean or enum-style points (for example, an AHU fan status) as horizontal bars. A toggle above the chart may label the current state (`Off` in the screenshot). ### Time range presets Tap the time dropdown to change the window. ![Time range menu with Today, Yesterday, Last 7 Days, and Custom Range](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trends-time-range.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=67acd62c9fc5480e5138d13d868fd622) | Preset | Typical use | | - | - | | `Today` / `Yesterday` | Same-day or prior-day troubleshooting | | `Last 2 Days` / `Last 7 Days` | Recent drift after an alarm | | `Last 30 Days` / `This Month` | Weekly reviews | | `Custom Range` | Exact start and end for an investigation | Select `Close` to return to the chart. ## Save a view Tap `Save View` to store the current points, range, and interpolation settings. ![Save View modal with Name field and Public checkbox](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-trends-save-view.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=39b5fb955f5888ad22fb4b0986ee6d4d) | Field | Description | | - | - | | `Name` | Label for the saved view (required) | | `Public` | When checked, others assigned to the building can open this view | Saved views complement [Bookmarks](/products/mobile-app/get-started/bookmarks) for personal shortcuts; public views behave like lightweight shared templates on mobile. ## Compare to web | Capability | Web | Mobile | | - | - | - | | Multi-axis layout and table view | Full | Chart-focused `Trends View` | | Advanced point configuration | Full | Filter + multi-select | | Save view (public/private) | Yes | Yes | | Export CSV | Yes | Not shown on mobile | ## Next steps > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Systems on mobile](/products/mobile-app/destinations/systems) > > Switch dashboard, graphic, and widget views. > [card] [Areas and floor plans](/products/mobile-app/building/areas) > > Browse floors, layers, and spatial triage. # Areas and floor plans on mobile Source: https://docs.kodelabs.com/products/mobile-app/building/areas Browse floors and zones, open layered floor plan maps with occupancy and temperature overlays, and jump to FDD from the KODE OS mobile app. Walk a floor and check occupancy, temperature, or fault status without opening each device one by one. `Areas` groups a building into floors, zones, and other spatial sections. Floor plans overlay live data on a map of that space. This page follows [Areas](/products/kode-os/areas) and [Floor plans](/products/kode-os/graphics/floor-plans) on the web. > [!NOTE] > > Area creation, ontology mapping, and floor plan authoring are web tasks. Mobile is for navigation, spatial monitoring, and triage. ## How to open > [tab] Areas > > From the building app launcher, select `Areas`. The list shows floors, zones, and other spatial groupings for the site. > [tab] Floor plan insights > > Some sites publish `Floor plan insights` as a separate launcher app. Open it, pick a floor such as `Floor 1`, then use the `Overview` dropdown when alternate layouts are published. ## Browse the area list When you open `Areas`, each row includes: | Element | Description | | - | - | | Area name | For example, `Parking`, `Floor 1`, `Floor 2` | | Device count | Total devices in parentheses | | Chevron | Opens the area detail map or device list | ![Areas list showing Parking, Floor 1, and Floor 2 with device counts](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-areas-list.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=08e59fc019918e45a32f0cdd7ef08c41) Use search (magnifying glass with history) to find an area. Use the sort/filter icon when your site exposes list filters. ## Floor plan overview Tap an area such as `Floor 1` to open the `Overview` floor plan. The header includes `FDD`, bookmark, and a more menu. ![Floor 1 overview map with green occupied and blue unoccupied markers](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-floor1-occupancy.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=5cccc0147e3f2f2866b15ef707d36023) Occupancy layer on Floor 1 ### Layer chips Below `Overview`, choose what to overlay on the map: | Layer | Shows | | - | - | | `Occupancy` | Occupied versus unoccupied zones | | `Temperature` | Zone temperature labels | | `Lighting` | Lighting state by zone | | `Air Quality` | IAQ-related values | | `Devices` | Equipment markers | Open `More` to switch layers when not shown as a chip. ![Floor 1 More menu with Lighting, Air Quality, Occupancy, and Devices layers](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-floor1-layers-menu.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=c0134c8dd6523998331fb12cd235a390) ![Floor 1 map with temperature pills such as 71.2 F on zones](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-floor1-temperature.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=80d9d06625e91da6c518036490a31e10) Temperature labels on rooms ### Map controls | Control | Action | | - | - | | Expand | Full-screen plan | | Recenter | Frame the floor in view | | Zoom +/- | Pinch or use on-screen buttons | | Settings | Toggle `Smart Markers` and `Legend` | | Bookmark | Save this floor and layer | | `FDD` | Open faults filtered to this floor | | Share | Share a link or image of the current view | Open the settings icon on the layer bar to toggle `Smart Markers` and `Legend`. The legend explains occupancy colors and device fault icons. ![Floor 1 with Smart Markers and Legend toggles and occupancy legend panel](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-floor1-legend.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=68f3c6a04b67ff9dad8a834740043e39) | Legend item | Meaning | | - | - | | Green person (check) | Occupied or in-range occupancy | | Blue person (x) | Unoccupied or out-of-range | | Yellow warning | Device down or faulty | | Chip icon | No smart value applied | Tap more (`...`) and choose `Share` to send the current floor context. ![Floor 1 more menu with Share and Close](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-floor1-share.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=0f6791f8701c72d71619abb7c9f76334) ## FDD from an area Tap `FDD` in the area header to open `FDD Reports` filtered to that floor. FDD flags equipment behavior that deviates from expected patterns, rather than a single instantaneous alarm. > [tab] Active > > `Active` lists faults that are currently open on the floor. > > ![FDD Reports active tab with Temperature Greater than Setpoint alert on Floor 1](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-area-fdd-reports.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=13d51763a95ca82494c100b0511e3050) > [tab] Inactive > > `Inactive` lists faults that are no longer active (history). See [Manage FDD faults on mobile](/products/mobile-app/diagnostics/manage-fdd-faults) for portfolio-level workflows. ## Drill into equipment From the map or area device list, open a unit to view points, trends, and commands. See [Devices on mobile](/products/mobile-app/building/devices) and [Systems on mobile](/products/mobile-app/destinations/systems). ## Compare to web | Capability | Web | Mobile | | - | - | - | | Area list and device counts | Full | Yes | | Spatial overview with layers | Full | Yes (`Overview` map) | | Dedicated floor plan graphics | Full | Yes (`Areas` or `Floor plan insights`) | | Create or edit areas and plans | Full | No | | FDD from area context | Full | Yes (`FDD` header link) | ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Areas on web](/products/kode-os/areas) > > Create areas and ontology mapping. > [card] [Floor plans on web](/products/kode-os/graphics/floor-plans) > > Author floor plan graphics and layers. # Data sources on mobile Source: https://docs.kodelabs.com/products/mobile-app/building/data-sources Review connector status, browse the API catalog, and run connection tests from the KODE OS mobile app. Check that a building's connectors are online before you troubleshoot a device in the field. A connector is the configured connection between KODE OS and one external system, such as a BACnet controller or a vendor API. Use `Data Sources` on mobile to verify connectors are online, browse available integrations, and run site-level maintenance while you are on site. This is the mobile view of [Data sources](/products/kode-os/data-sources) on the web. > [!WARNING] > > Connector creation, credential edits, and discovery jobs are not available on mobile. Use the web client for provisioning and configuration. ## Open Data Sources From the building app launcher, select `Data Sources`. ![Data Sources list with green online indicators for Demo JACE and Carma connectors](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-data-sources.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=61f9ba81f28ac9868c0017444febc387) The header includes a search/history icon for finding connectors quickly. A notification bell may appear when your site has data-source alerts. > [tab] Data Sources > > The `Data Sources` tab lists live connectors for the current site. Each row shows: > > | Element | Description | > | - | - | > | Green dot | Connector is online and communicating | > | Name | Connector label (for example, `Demo JACE`) | > | Subtitle | Platform or vendor (for example, `Tridium Niagara`, `Carma`) | > > Tap a row when drill-down is enabled to view connector details on mobile or web. > > ### Actions menu > > Tap the three-dot menu in the header to open site-level maintenance actions. > > ![Data Sources action sheet with Test Connections, Refresh Cache, and Close](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-data-sources-actions-menu.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=fe482c63592361bfef953c5d132bc952) > > Test connections and refresh cache > > | Action | When to use | > | - | - | > | `Test Connections` | Verify all connectors respond after network or VPN changes | > | `Refresh Cache` | Pull the latest metadata after web-side connector updates | > | `Close` | Dismiss the menu | > [tab] API Catalog > > Browse integration types your organization can provision on web. Entries are grouped by category (for example, `Access Control`). > > ![API Catalog tab listing Access Control integrations such as Infinias, Zerv, and Avigilon ACM](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-data-sources-api-catalog.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=e9b64d7d65023ab24543ed96dc8d8064) > > | Catalog entry | Description | > | - | - | > | Vendor row | Logo, product name, and chevron to open details | > | `Access Control` | Badge readers, door controllers, and related systems | > > The catalog is read-only on mobile. Add or configure connectors from [Data sources](/products/kode-os/data-sources) on the web. ## Compare to web | Capability | Web | Mobile | | - | - | - | | View connector online status | Yes | Yes | | Test connections / refresh cache | Yes | Yes | | Browse API catalog | Yes | Yes (read-only) | | Add connector, edit credentials, discovery | Yes | No | ## Next steps > [card] [Systems on mobile](/products/mobile-app/destinations/systems) > > Switch dashboard, graphic, and widget views. > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Data sources on web](/products/kode-os/data-sources) > > Add connectors and run discovery. # Devices on mobile Source: https://docs.kodelabs.com/products/mobile-app/building/devices Browse equipment, view live points, write overrides, and open related schedules or diagnostics from the KODE OS mobile app. A **device** is a piece of equipment in the building—for example an air handler (`AHU`) or variable air volume box (`VAV`). On mobile you open equipment from `Systems`, `Areas`, search, or graphics, then monitor points and jump to related apps. Devices match [Devices](/products/kode-os/devices/devices) on the web for day-to-day operations. > [!WARNING] > > Point writes affect live equipment. Confirm the site, device, and priority before you tap `Write Point`. See [Points on mobile](/products/mobile-app/building/points#write-a-point) for the full override form and bulk writes. ## Open the device list From the building app launcher, select `Devices`. The header shows `Devices`, search, and filters. ![Devices list filtered by ahu with search and filter icons in the header and AHU rows](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-devices-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=453ed406d498d3171ff78db08f933914) Devices list with search chip and filter badge ## Filter the list When browsing many units, open `Device Filters` before you select equipment. ![Device Filters screen with Ontology Type ahu and Apply button](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-filters.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=1305644fe621cd886464f974a37cf61b) Device Filters with Ontology Type set to ahu | Field | Description | | - | - | | `Status` | Online, offline, or fault state | | `Type` | Equipment category | | `Ontology Type` | Standardized equipment tag (for example, `ahu`). Ontology maps vendor names to KODE types. | | `Areas` | Floor or zone | | `Connectors` | Integration connection that feeds the device | | `Origin Type` | Physical versus virtual | | `Point Count` | Devices by point volume | Tap `Clear All`, set criteria, then `Apply`. ## Device detail Select a device to open its detail view (for example, `AHU_3`). The header shows the device name, bookmark, and `More` menu. Expand `Details` for area and building. Sensor rows show live values. A pencil icon marks writable points. ![AHU\_3 device detail with Details, Temperature sensors, and graph icon](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-device-ahu-dashboard.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=7ff9c3a5ba82b74ef0152d08ce3e5052) AHU\_3 dashboard with Temperature sensors ### Switch view mode Tap the current view label (for example, `Dashboard View`) to change layout: | View | Use when | | - | - | | `Dashboard View` | Grouped sensors and setpoints by point field | | `New Graphic View` | Floor plan or equipment graphic | | `Basic View` | Compact list of key points | ![AHU\_3 view selector showing Dashboard View, New Graphic View, and Basic View options](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-view-selector.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=99fe2ff5b05bf292e67f853669449e5b) Dashboard, New Graphic, and Basic views ### Trend points on the device Tap the graph icon on a point group such as `Temperature` to open the device trend for checked sensors. Switch between chart and table. Change the window from the time dropdown (for example, `Last 2 Days`). For multi-point trending across many devices, use [Trends on mobile](/products/mobile-app/analytics/trends). ### Write a point Tap the pencil on a writable sensor to open `Write Point`. ![Write Point command window with priority Override, value, duration, reason, and Write Point button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-write-point-override.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=04ddf349280063428cb31376a0cdf33c) Write Point command for Discharge Air Temp Set priority, value, duration, and reason, then tap `Write Point`. For field definitions and bulk writes, see [Write a point](/products/mobile-app/building/points#write-a-point). > [!NOTE] > > To bookmark a device, add a note, or set `Remind Me`, see [Use bookmarks on mobile](/products/mobile-app/get-started/bookmarks#create-or-edit-a-bookmark). ## Device menu Open the `More` (`⋯`) menu for cross-module shortcuts. ![AHU\_3 three-dot menu with Schedules, Linked Devices, References, Attachments, FDD, FTT Reports, Work Orders, Edit Device, and Share](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-device-actions-menu.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=e6ee08b5725a152dc71da2a1a04124e7) Cross-module shortcuts on AHU\_3 | Menu item | Opens | | - | - | | `Schedules` | Schedules linked to this device — [Schedules](/products/mobile-app/operations/schedules) | | `Linked Devices` | Related equipment | | `References` | Which sensors and setpoints map to the device template | | `Attachments` | Photos and files | | `FDD` | Fault reports for the device — [Events](/products/mobile-app/events/work-with-events#fdd-reports-from-a-device) | | `FTT Reports` | Functional test history — [FTT](/products/mobile-app/diagnostics/functional-testing#ftt-reports-from-a-device) | | `Work Orders` | [AssetOps work orders](/products/mobile-app/operations/work-orders) when enabled | | `Edit Device` | Limited metadata edits | | `Share` | Share device context | > [accordion] Schedules from a device > > `Schedules` lists schedule cards with current value, next change, and point references. Tap `View Schedule` for the weekly or calendar editor. > > ![Schedules for AHU\_3 showing current value False, next value change N/A, and Occupancy command point reference](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-schedules.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=b14980623e4b7948832aa0129d45f1b0) > > AHU Floor 1 schedule card on AHU\_3 > [accordion] References > > `References` shows which sensors and setpoints map to the device template. Use checkboxes to select points, then tap the graph icon to trend them. Pencil icons open writes when your role allows. > > ![References for VAV\_310 with temperature sensors and zone temperature setpoint](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-references.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=ac8156cd00c4c8dd6ae1452c9ecc6a18) > > Reference points for VAV\_310 > [accordion] Attachments and Edit Device > > `Attachments` lets you capture or upload photos for the asset. > > ![Attachments screen with Take Photo and Choose from Gallery](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-device-attachments.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d50caabf5f3f390ec7af34058130dcbd) > > When enabled, `Edit Device` updates name, location, type, area, and other metadata. Batch updates, templates, and virtual device creation remain on web [Devices](/products/kode-os/devices/devices). ## Compare to web | Capability | Web | Mobile | | - | - | - | | Device list and filters | Full | Yes | | Dashboard / graphic / basic views | Full | Yes | | Point trends (chart and table) | Full | Yes | | Write point / override | Full | Yes | | References, schedules, FDD, FTT from device | Full | Yes | | Attachments (photos) | Full | Yes | | Bookmark with reminder | Limited | Yes ([Bookmarks](/products/mobile-app/get-started/bookmarks)) | | Device templates, batch update, discovery | Full | Web only | ## Next steps > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Bookmarks](/products/mobile-app/get-started/bookmarks) > > Pin devices and views with reminders. > [card] [Schedules on mobile](/products/mobile-app/operations/schedules) > > Edit weekly days, special events, and holidays. > [card] [Work orders on mobile](/products/mobile-app/operations/work-orders) > > Triage, assign, and update AssetOps work. > [card] [Devices on web](/products/kode-os/devices/devices) > > Templates, batch update, and discovery. # Manual meters on mobile Source: https://docs.kodelabs.com/products/mobile-app/building/manual-meters Add manual meters, log readings, and review reading history from the KODE OS mobile app. Register an offline utility meter and log its reading while you are standing in front of it. Each manual meter is stored as a device in KODE OS with **accumulator** and **differential** points. When you add a reading, choose whether you are entering the meter display value or a calculated consumption total. This page follows [Create and manage manual meters](/products/kode-os/devices/manual-meters) on the web. > [!NOTE] > > The `Manual Meters` app appears in the building launcher when it is published for your site and role. ## Open Manual Meters Select `Manual Meters` from the building app launcher. The list is scoped to the current floor or area when a filter applies (for example, `FLOOR 1`). Use the header icons to: | Icon | Action | | - | - | | History | Refresh or review recent activity | | Filter | Narrow the list | | Add | Open `Add Meter` | ![Manual Meters list with energy meters, units such as kWh, and floor location](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-manual-meters-list.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=5221c201dc0f4bf5e98887d0432d6b2d) Each row shows meter type, name, location, unit badge, and identifier tag. Tap a row to open meter detail. ## Add a meter Tap the `Add` icon in the header. ![Add Meter form with Basic Information, Type and Unit, Configuration, and Additional Information sections](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-manual-meters-add-meter.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=491d146a84f05ebd2703332fd6fbdd4b) Complete the required fields (marked with an asterisk and red border until valid): | Section | Fields | | - | - | | `Basic Information` | `Meter Name`, `Location`, `Located In`, `Connector` | | `Type & Unit` | `Meter Type`, `Unit of Measurement` | | `Configuration` | `Conversion Factor` (default `1.0`) | | `Additional Information` | `Serial Number`, `Identifier`, `Manufacturer`, `Vendor Name` (optional) | Tap `Add Meter` when the form is complete. Tap `Cancel` to discard. ## Meter detail and reading logs ![Manual meter detail with type Energy Meter, connector N4, Located In path, and empty Reading Logs](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-manual-meters-meter-detail.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=ee99c37317245e5df63479274fb4e149) > [tab] Details > > | Section | Content | > | - | - | > | `Details` | `Type`, `Location`, `Connector`, `Located In` breadcrumb | > > Tap `Edit Device` in the header to change device metadata. > [tab] Reading Logs > > Historical readings appear here; the list shows `No Data` until the first entry. > > Tap the `+` icon on `Reading Logs` to add a reading. ## Add a reading ![Add Reading form with Date, Value, Notes, Attachments, and Value Preview](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-manual-meters-add-reading.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=a0af876565a47a64ccf58b8252c02cb6) | Field | Description | | - | - | | `Reading type` | `Accumulator` for the value on the meter display, or `Differential` for calculated consumption over a period | | `Date` | Reading timestamp | | `Value` | Native value for the selected reading type | | `Notes` | Optional context | | `Attachments` | Photos or files (`+ Add`) | | `Value Preview` | Converted value after the conversion factor (for example, `0x1.0 = 0 BTU`) | Tap `Add Reading` when `Date` and `Value` are filled. The button stays disabled until required fields are valid. > [!WARNING] > > Compare `Value Preview` to the previous reading before you save. Large jumps may indicate a typo or unit mismatch. ## Edit device metadata ![Edit Device form for manual meter with name, location, type, and area fields](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-manual-meters-edit-device.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=68c716fff945573778796875125de6be) Update `Device Name`, `Location`, `Type`, `Area`, and other fields. Tap `Edit Device` to save or `Cancel` to discard. ## Compare to web | Web capability | Mobile | | - | - | | Manual Meters list | Yes | | Add single meter | Yes | | Add reading per meter | Yes | | Reading logs on device | Yes | | Edit device metadata | Yes | | Batch add meters or readings | Use web | | CSV upload | Use web | | Add metadata columns in bulk | Use web | ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Manual meters on web](/products/kode-os/devices/manual-meters) > > Batch add meters and CSV upload. > [card] [Trends on mobile](/products/mobile-app/analytics/trends) > > Chart points and save shared views. # Points on mobile Source: https://docs.kodelabs.com/products/mobile-app/building/points Browse point status, filter the list, and write or bulk-write values from the KODE OS mobile app. A point is a single read or write value on a device, such as a temperature reading or an on/off status. Use `Points` on mobile to review health badges, filter the list, and write overrides from `Points`, `Writable Points`, or a device sensor. This page follows [Points](/products/kode-os/points/points) on the web. > [!WARNING] > > Writes affect live equipment. Confirm site, point, and priority before you tap `Write Point`. ## Open Points Select `Points` from the building app launcher. ![Points screen with Ok, No Value, Overridden, and FDD status counts](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-points-status-summary.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=c6b163697e0020386df7557ea7d89bcc) Use the `Points` and `Statuses & states` tabs to switch between the point list and state-oriented views. ### Status summary Colored badges summarize how many points are in each state: | Badge | Meaning | | - | - | | `Ok` | Healthy, current value | | `Down` | Communication or source issue | | `Fault` | Equipment fault | | `Disabled` | Point disabled | | `No Value` | No reading at this time | | `Overridden` | Active override | | `FDD` | An FDD routine flagged the point | | `Stale` | Value older than expected | Tap a badge to filter the list to that status when supported. ## Browse the point list Each row shows point name, device tag (for example, `AHU_1`), data type icon, live value, and status dot. Writable rows show a pencil icon—tap the row or the pencil to open `Write Point`. See [Write a point](#write-a-point) for the full override form. ![Points list with AHU filter chip showing HtgVlv\_out and CoolingNot values](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-points-list-ahu.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=5f5f0f32693f27053cafd13743ec6cd1) Points filtered to AHU | Element | Description | | - | - | | Type letter | `N` numeric, `B` true/false, `S` string/source form | | Green dot | Point is online | | Pencil | Writable point—tap the row or the pencil to open `Write Point` | | `Write Point` | Override form for a single writable point—see [Write a point](#write-a-point) | | Filter chip | Active filter (tap `x` to remove) | Header icons include search/history, filter (badge shows active filter count), and more options. ## Apply point filters Tap the filter icon to open `Point Filters`. ![Point Filters with Field, Kind, Device Type, Area, and Data Source dropdowns](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-point-filters.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=730a15b2963c7963b407cd4018eae8f6) | Field | Description | | - | - | | `Field` | Point field template (discharge air temp, fan status, and so on) | | `Kind` | Point kind in the ontology—the standard naming system that maps a vendor's raw point names to consistent KODE OS types | | `Device Type` | Equipment category | | `Canonical Type` | Canonical type tag | | `Area` | Floor or zone | | `Data Source` | Connector | Tap `Clear All`, set criteria, then `Apply`. ## Write multiple points Open the three-dot menu on `Points` and choose `Write Multiple Points` to start a bulk write from the full point list. ![Points menu with Write Multiple Points and Close](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-points-write-multiple.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=5ec8686243816211141b6d9ccff526f7) For site-wide writable source forms, use `Writable Points` instead (see below). ## Writable points `Writable Points` lists only points your role can command, often grouped by source form—a label for how the point is wired, shown as a virtual (KODE OS-computed) or physical (mapped to a real controller point) row. ![Writable Points list with virtual and physical source forms](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-writable-points.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=e108dfffeed1f3acafb1de4089c3dffa) Filter to an equipment type (for example, `AHU`), select rows, then tap `Write Point` on the footer bar. ![Writable points filtered to AHU with HtgVlv\_out and CoolingNot selected](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-writable-points-bulk-write.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=95694844abd0c11a788ea5da129d19fa) Two points selected for bulk write | Footer control | Action | | - | - | | `Cancel` | Clear selection | | `Write Point` | Open the write flow for selected points | This matches [Commanding points](/products/kode-os/points/commanding-points) on the web. ## Write a point Tap a writable row or the pencil on a [device](/products/mobile-app/building/devices) sensor to open the override form. This is the canonical write flow, whether you start from a single point row, `Writable Points`, or a device sensor. ![Write point form for HtgVlv\_out with priority Override and value 0.0](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-write-point-htgvlv.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=00827921c7bcab8ce24b335b7125af18) Override for HtgVlv\_out | Field | Description | | - | - | | `Priority` | BACnet priority level (for example, `Override`)—a 1–16 ranking that controllers use to decide which command wins when more than one source writes to the point | | `Value` | Target with +/- steppers | | `Duration` | Hours and minutes, or `Permanent` | | `Reason` / `Specific Reason` | Audit categories | | `Level` / `Current Value` | Read-only context | Submit with `Write Point`. Use the history icon for recent commands on that point. ## Compare to web | Capability | Web | Mobile | | - | - | - | | Points list and status badges | Full | Yes | | Point filters | Full | Yes | | Mass write / export | Full | `Write Multiple Points` and Writable Points | | Points batch update, export CSV | Full | Not shown on mobile | | Edit point metadata | Full | Limited | ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Trends on mobile](/products/mobile-app/analytics/trends) > > Chart points and save shared views. > [card] [Commanding points on web](/products/kode-os/points/commanding-points) > > Advanced commanding and mass write. # Building BI on mobile Source: https://docs.kodelabs.com/products/mobile-app/destinations/building-bi Navigate Building BI collections, open published dashboards, and apply filters on the KODE OS mobile app. Check a published dashboard from the field instead of waiting until you're back at a desk. Mobile delivers the analytics published from [Building BI](/products/building-bi/overview), the KODE OS analytics and dashboard module. You browse collections, open dashboards and reports, apply filters, and favorite items for quick return. Dashboard design and publishing stay on the web. ## How to open Building BI > [tab] From portfolio > > Swipe up the `Portfolio` sheet and select `BuildingBI`. The map stays visible behind the sheet until the module loads. > > ![Portfolio sheet with Building BI module listed below Sites](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi-portfolio-nav.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d4b021a93548654164fe7268fd0b009e) > > Building BI in the portfolio module list > [tab] From a site > > After you [enter a site](/products/mobile-app/portfolio/portfolio-and-sites#enter-a-site), open `Building BI` from the building app launcher. Content is scoped to that site's published artifacts. ## Collections home The `BuildingBI` home screen lists collections as expandable sections. Only collections and dashboards your administrator published to mobile appear here. ![Building BI home with Favorites, Dashboard Collection, and Switch Site footer for KODE 1420 Office](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=bf729401d7f0bfb6c581e87c500fbe4b) ### Collection sections | Section | Typical contents | | - | - | | `Favorites` | Starred dashboards such as `Lighting Occupancy` and `Operations Dashboard` | | `Dashboard Collection` | Curated sets such as `Operations`, `Comfort & Air Quality`, `Traffic & Occupancy`, and `Lighting` | | `Dashboards` | Individual dashboards with author and age metadata | ### Row and header controls | Element | Action | | - | - | | Chevron on section header | Expand or collapse the collection | | `Published` badge | Confirms the collection is available on mobile | | Eye icon | Open the published collection view | | Age label (for example, `7 days ago`) | Last publish or sync time | | Dashboard row | Tap to open that dashboard | | Star | Favorite the dashboard for quicker access | | Overflow (⋯) | Share or secondary actions when enabled | | Header search/history icon | Search dashboards or open recent items (organization configuration) | | Bell (FAB) | Notifications related to Building BI or the current site | ## Open a dashboard or report **1. Expand a collection** Tap the section header or chevron to show child dashboards. **2. Select a report** Tap a row such as `Operations Dashboard`. The dashboard opens full screen with its page title and tabs. **3. Switch report pages** Use the title dropdown (for example, `Operations Dashboard` ▼) to change report definitions or tabs such as `Overview` when the author published multiple views. ![Operations Dashboard Overview with zone temperature chart, average floor temperature heatmap, and Device Details and Floor Plans links](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi-energy-report.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=faa24365ec082cfe76942a8de82e88a1) Operations Dashboard — Overview Inside a dashboard you can: * Scroll vertically through KPI tiles, charts, tables, and floor plan graphics * Open linked views such as `Device Details` and `Floor Plans` when the author added them * Tap the blue refresh FAB to reload data after filters change When the author enabled `Mobile Layout` on the web, widgets resize and stack for phone screens. Dashboards without that configuration render the desktop layout instead. Scroll vertically in portrait or rotate to landscape for a wider view. ![Training Overview dashboard in portrait with weather widget, floor plan graphic with temperature labels, and average temp heatmap without a mobile layout configured](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi-no-mobile-layout.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=651f0341b2ac45dc216372a31ec37f21) Training Overview without mobile layout (portrait) ![Training Overview dashboard in landscape with weather widget, floor plan graphic, filter panel, and AVG Temp heatmap without a mobile layout configured](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi-no-mobile-layout-landscape.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=8c8b58b3865087ca49a69b7c482813be) Training Overview without mobile layout (landscape) ## Apply filters Tap the filter icon in the dashboard header to open `Filters`. ![Filters screen with Date Time Local row and Apply button](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-building-bi-filters.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a1c5d230b9995bdfcf9c68c9020a6370) ### Filter bar segments The top icon row switches filter categories: | Segment | Purpose | | - | - | | Funnel | Standard dimension filters | | Document + funnel (highlighted when active) | Report- or template-specific parameters | | Funnel with arrow | Saved or reset filter sets when configured | ### Filter rows Tap a row such as `Date Time Local` to set the range or dimension. Select `Apply` at the bottom to refresh the dashboard. Cancel with the back arrow to discard changes. > [!NOTE] > > Available filters depend on how the dashboard was authored on the web. If only `Date Time Local` appears, other slicers may be fixed inside the report layout. ## Favorites and return navigation * Tap the star on a dashboard row in the collections list to favorite it. * Use the back arrow in the dashboard header to return to `BuildingBI` collections. * Use the `Portfolio` sheet to switch to `Sites` or another portfolio module without signing out. ## What to do on web vs mobile | Task | Platform | | - | - | | Create or edit dashboards and widgets | Web [Building BI](/products/building-bi/dashboards) | | Publish to mobile / manage deployment | Web [Deployment manager](/products/building-bi/deployment-manager) | | Browse and filter published content | Mobile (this guide) | | Collections and data sources setup | Web [Collections](/products/building-bi/collections) | ## Next steps > [card] [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites) > > Use the map, site cards, and site switcher. > [card] [Trends on mobile](/products/mobile-app/analytics/trends) > > Chart points and save shared views. # Systems on mobile Source: https://docs.kodelabs.com/products/mobile-app/destinations/systems Browse plant systems, switch dashboard, graphic, and widget views, and manage system devices from the KODE OS mobile app. Open a chiller plant or air handling system as one unit instead of hunting through individual devices. A system is a grouping of related equipment—for example every device in a chiller plant—shown together in one view. This page follows [Systems](/products/kode-os/systems) on the web. > [!NOTE] > > System creation, tagging, and graphic authoring require the web Systems module. Mobile is for operations and monitoring. ## Open Systems Select `Systems` from the building app launcher. ![Systems list with Chiller Plant row and Chiller type label](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-systems-list.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=8f0e4ad07b9880ee457055582699baad) Each row shows system name, optional status, and type (for example, `Chiller`). Tap a row to open the system. Use search and filter icons in the header when your site exposes them. ## System header Inside a system such as `Chiller Plant`, the header includes: | Control | Action | | - | - | | Back | Return to the systems list | | Bookmark | Save this system for quick access | | More (`...`) | System Devices, Attachments, Share, Edit System | | View selector | Switch Dashboard, Graphic, or Widget view | ## Switch view mode Tap the view dropdown to change how the system is presented. ![Chiller Plant Widget view with view mode action sheet showing Dashboard View, Graphic View, and Widget View options](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-systems-view-selector.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=d8f3f6767fd9901a6bb108a428a00fc5) Dashboard, Graphic, and Widget views | View | Purpose | | - | - | | `Dashboard View` | Grouped sensors and setpoints by point field | | `Graphic View` | Published schematic with live values | | `Widget View` | Compact point list for quick reads | > [tab] Dashboard > > `Dashboard View` lists points by category (for example, `Temperature` under `Loop_System`). Checkboxes select points for trends; pencil icons open writes. > > ![Chiller Plant dashboard with Entering and Leaving Chilled Water Temp sensors](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-chiller-dashboard.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=7f636ac6d2b2f31d07cb321a954e55a1) > > Expand `Details` to confirm `System Name` and `Type`. > [tab] Widget > > `Widget View` emphasizes live values for operational points such as temperatures, enable commands, and pressures. > > ![Chiller Plant widget view with loop system entering temp, enable command, and pressures](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-chiller-widget.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=d06ff3d471edd9b3696ad2979ead9e6b) > > Tap the pencil beside a point to open [Points on mobile](/products/mobile-app/building/points) or [Trends on mobile](/products/mobile-app/analytics/trends). > [tab] Graphic > > `Graphic View` renders the system schematic published on web. Use `Base Layer` and map controls to pan and zoom. > > ![Chiller Plant graphic view with chiller modules, piping, and Unit Control table](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-chiller-graphic.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=5f4a862c296b87b8dc11fc2c10ed6e23) > > Chiller plant schematic with CW and CHW loops > > Temperature and pressure labels update in place on the graphic. Tap equipment on the diagram when drill-down is enabled. ## System menu Open more (`...`) for system-level actions. ![Chiller Plant menu with System Devices, Attachments, Share, and Edit System](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-chiller-menu.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=c5a195d43562e038912ec492934fa261) ### System Devices `System Devices` lists child equipment and points grouped under the system (for example, `Loop_System`). ![System Devices for the loop system with chilled water valve and pressure points](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-devices.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=5af2be983beae048eb8ef869b6ad2d4f) Select checkboxes to include points in a trend or bulk action. Pencil icons mark writable points. ### Attachments `Attachments` lets you capture or upload photos for the system record. ![System Attachments with Take Photo and Choose from Gallery](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-attachments.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=0c9acbe55b188e42d2209bfc18e3ee53) ### Edit System When your role allows, `Edit System` updates name, type, and tags. ![Edit System form with name Chiller Plant and type Chiller](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-system-edit.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=f305f034ed954ffa0ab861716d675232) Tap `Save` to apply or `Cancel` to discard. ## Compare to web | Capability | Web | Mobile | | - | - | - | | Systems list | Full | Yes | | Dashboard / graphic / widget views | Full | Yes | | System Devices point list | Full | Yes | | Attachments (photos) | Full | Yes | | Limited metadata edit | Full | Yes (when enabled) | | Create system, author graphics | Full | Web only | ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Areas and floor plans](/products/mobile-app/building/areas) > > Browse floors, layers, and spatial triage. > [card] [Systems on web](/products/kode-os/systems) > > Create systems and author graphics. # FDD on mobile Source: https://docs.kodelabs.com/products/mobile-app/diagnostics/fdd-overview Choose the right FDD screen on mobile for live triage, grouped incidents, historical analytics, or fault lifecycle metrics. FDD (Fault Detection and Diagnostics monitors equipment and surfaces operational issues in real time.) finds equipment problems from sensor data and rules, not only from simple instantaneous alarms. On mobile, FDD uses two building apps that match [FDD](/products/fdd/overview) on the web: * `FDD Events` — live events, grouped incidents, and analytics dashboards * `FDD Faults` — fault records for a rule on a device over time ## Which screen should you open? | Screen | Use when you need to… | Example | | - | - | - | | [Events list](/products/mobile-app/events/work-with-events) | Triage live events, filter, and acknowledge | “This VAV just went into damper fully open—who owns it?” | | [Incidents](/products/mobile-app/events/work-with-events#incidents-list) | See many related events as one issue | “Six FCUs on Floor 1 share the same cooling problem.” | | [Event dashboards](/products/mobile-app/events/customize-event-dashboard) | Review open load or period trends with KPI cards | “How many high-priority events are open right now?” | | [Manage faults](/products/mobile-app/diagnostics/manage-fdd-faults) | Inspect cost, occurrences, solutions, and long-running faults | “Has this temperature-greater-than-setpoint fault been open for days?” | **Events** are individual findings in the stream. **Incidents** group related events under one ID. **Faults** summarize how often a routine fires on a device and how long it stays open. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart TB FDDEvents["FDD Events app"] FDDFaults["FDD Faults app"] FDDEvents --> Events["List: Events / Active"] FDDEvents --> Incidents["List: Incidents"] FDDEvents --> Historical["Historical + dashboards"] FDDFaults --> FaultViews["Faults / Device / Routine"] FDDFaults --> FaultDetail["Fault detail + trends"] classDef Sky stroke-width:1px,stroke:#374D7C,fill:#E2EBFF,color:#374D7C class FDDEvents,FDDFaults,Events,Incidents,Historical,FaultViews,FaultDetail Sky ``` ## Portfolio context Historical dashboards may show a `Portfolio` sheet when you are scoped to all sites. Select `All Sites` to change portfolio filters, or `Switch Site` in building modules to focus on one property. ## What stays on the web | Task | Platform | | - | - | | Routine authoring | Web | | Notification policies | Web | | Configuration and domains | Web | | Full work order administration | Web (mobile can create limited work orders from events and faults) | ## Next steps > [card] [Events on mobile](/products/mobile-app/events/work-with-events) > > Filter, acknowledge, and investigate events. > [card] [Event dashboards](/products/mobile-app/events/customize-event-dashboard) > > Review Active and Historical FDD KPIs. > [card] [Manage FDD faults](/products/mobile-app/diagnostics/manage-fdd-faults) > > Inspect fault lifecycle metrics and trends. # Functional testing on mobile Source: https://docs.kodelabs.com/products/mobile-app/diagnostics/functional-testing Check FTT pass rates, open failed runs, and start device tests from the KODE OS mobile app. The **Functional Testing Tool (FTT)** runs automated checks on building equipment for commissioning and ongoing validation. On mobile, the `FTT` app shows pass rates, failed sequences, and building scores from [Functional Testing Tool](/products/ftt/overview) on the web. Use mobile FTT to review results in the field. Project setup, workflow authoring, and deployment stay on the web ([FTT deployment](/products/ftt/deployment)). ## Common field tasks | Task | Where to start | | - | - | | Check overall pass rate for the building | [FTT home](#ftt-home) KPI tiles | | Open a failed or completed run | `View All` → `History` | | Review a scheduled project | `View All` → `Projects` | | Start a test on one unit | Device `More` menu → `FTT Reports` → `Start New Test` (when enabled) | ## FTT home Open `FTT` from the building app launcher (or from the portfolio sheet when published). ![FTT dashboard with average score, tested devices, and executed tests KPIs](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-ftt-kpi-summary.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=e6ea88d4d306e09d240083588dfee253) Summary KPI tiles | KPI | Meaning | | - | - | | `Average Score` | Aggregate pass rate | | `Tested Devices` | Devices included in recent runs | | `Devices with Failures` | Devices that still have failing sequences | | `Executed Tests` | Total test executions in range | | `Successfully Executed Tests` | Pass share | | `Average Test Duration` | Mean runtime per sequence | Select `View All` for the full test list. Use the `filter` icon to change buildings or date scope. Scroll the home screen for sequence, trend, and breakdown charts. > [accordion] Chart reference on FTT home > > | Chart | Shows | > | - | - | > | `Sequence Success Scores` | Pass versus fail counts per sequence step | > | `Buildings Score` | Comparative bar chart across sites in portfolio context | > | `Workflows` | Per-workflow archived, failed, and completed counts with score trend | > | `Device Types` | Share of tested devices by equipment type | > | `Average Score by Area` | Score breakdown by floor or area | > | `Status` | Overall completion gauge | > | `Score Trend` | Performance over time | > | `Test Times` | When tests run by day of week and hour | ## History and projects Tap `View All` at the top of the home screen to open test history and projects. > [tab] History > > The `History` tab lists completed runs with workflow name, score badge, timestamp, and device link. Tap a row to open that test. > > ![FTT History tab listing V2 VAV Damper Operation tests with score badges and device links](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-ftt-history.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=828b10ed20118f2fffaf92d1aea16e4c) > > Completed test runs > > > [tab] Details > > > > The `Details` tab shows building, device, workflow, score, timing, and status. > > > > ![FTT test Details tab with building, device, workflow, 100 percent score, and Completed status](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-ftt-test-details.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=5c2232b159474991976355bfe29434df) > > > > Scroll for `Score Results` (pass rate over time) and `Sequences Results` (passed versus failed counts by run date). > > > [tab] Test > > > > The `Test` tab shows the step-by-step run timeline. Each step lists timestamps, sequence descriptions, sensor readings, and pass or fail outcomes. The run ends with `Finished` and the final score. > > > > ![Test tab timeline showing Open Damper sequence and Finished score of 100 percent](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-ftt-test-timeline-finished.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=7e912e84333bdd39657e67af3849a987) > > > > Finished score > [tab] Projects > > Review scheduled and executed [FTT projects](/products/ftt/projects). Each card shows the project name, workflow, device count, status (`Scheduled` or `Executed`), recurrence (`Recurring` or `Once`), and run time. > > ![FTT Projects tab listing VAV Damper Operation, Cooling test, and Test Training with status and recurrence badges](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-ftt-projects.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=39c687ff6fe3a6c7e66fea2b90e5d6db) > > Scheduled and executed runs > > Tap a row to open the project. > > | Tab | Shows | > | - | - | > | `Details` | Workflow, device count, completion percentage, schedule dates, status, recurrence, description, and reason | > | `Tasks` | Execution groups with status, run times, device count, and completion percentage | > | `Devices` | Progress by area and status, then individual device rows | ## Start a test from a device When your site enables mobile test runs, you can start a test from equipment. **1. Open FTT Reports** From a [device](/products/mobile-app/building/devices#device-menu), open the `More` menu and choose `FTT Reports`. **2. Review past runs** Each card shows the workflow name, device, area, reason, status badge, duration, and timestamp. Tap a report to open the run timeline and final score. **3. Start New Test** Tap `Start New Test`. Choose a `Workflow` and `Reason`, add an optional `Workflow Description`, then tap `Continue`. When your role includes **View FTT Parameters for Manual Test**, you can review or change workflow parameters before you continue. When that permission is off, parameters stay hidden and the run uses the configured defaults. See [FTT permissions](/products/launchpad/client-organizations/apps/permissions-reference) and [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device) on web. ![FTT Reports list with Failed and Archived test cards and Start New Test button](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-ftt-reports.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=d05e827dbb94341e6dfbe5efd16c26ee) Test history with Start New Test ![Run New Test form with workflow, reason, and description filled and Continue enabled](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-ftt-run-new-test-form.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=d7159813715e5bd8f71ef57f9e7dcf54) Workflow and reason selected > [!NOTE] > > If `Start New Test` is missing, your site is monitoring-only on mobile. Use web FTT to run or schedule tests. When no tests exist yet, the list can be empty while `Start New Test` still appears. For building-wide KPIs, use the [FTT home](#ftt-home) screen from the app launcher. ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Events on mobile](/products/mobile-app/events/work-with-events) > > Filter, acknowledge, and investigate events. > [card] [FTT on web](/products/ftt/overview) > > Author workflows and deploy projects. # Manage FDD faults on mobile Source: https://docs.kodelabs.com/products/mobile-app/diagnostics/manage-fdd-faults Browse, filter, and investigate FDD faults by fault, device, or routine on the KODE OS mobile app. Review which equipment has a recurring fault, how long it has been open, and what to do next. `FDD Faults` groups faults by equipment or routine, shows occurrence metrics, and links to point trends for diagnosis. This page follows [Faults](/products/fdd/faults) on the web. ## Events vs Faults FDD surfaces two related but distinct views of equipment problems: | Screen | Shows | Use for | | - | - | - | | [Events list](/products/mobile-app/events/work-with-events) | Individual findings as they happen | Live triage and acknowledgment | | `FDD Faults` (this page) | A routine on a device summarized over time | Lifecycle metrics and root-cause investigation | | [Incidents](/products/mobile-app/events/work-with-events#incidents-list) | Many related events grouped together | Portfolio-level analytics | Open fault detail from `FDD Events` when you follow a device link, from [FDD Reports from a device](/products/mobile-app/events/work-with-events#fdd-reports-from-a-device), or from the `FDD Faults` app launcher. ## Open FDD Faults Select `FDD Faults` from the building app launcher. Use the header filter icon for area and date chips such as `Last 7 Days`. Use the history icon to refresh when streaming is enabled. ## Group faults by view The header dropdown switches how the list is organized: ![FDD Faults view menu with Faults, Device, and Routine options](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-faults-view-menu.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=7109a2c86b600a6091c622e8cee30fb1) Faults, Device, and Routine | View | List shows | | - | - | | `Faults` | One row per open fault on a device | | `Device` | Equipment with fault counts and floor | | `Routine` | Diagnostic routines with counts and duration | > [tab] Faults > > ![FDD Faults list with VAV and FCU devices and Open status](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-faults-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=fd1759bdb44690e51ba9a4f7392be36c) > > Each row includes: > > | Element | Description | > | - | - | > | Device ID | Equipment such as `VAV_208` or `FCU_204` | > | Routine title | Fault name (for example, `Temperature Greater than Setpoint while Occupied`) | > | Age | Relative time (for example, a day, 6 hours) | > | Status | `Open` or other workflow state | > > Tap a row for a summary sheet, then `Fault Details` for the full page. > > ![Fault sheet for VAV\_208 with routine, occurrences, and area Floor 2](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-detail-sheet.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=04f993b6eaa52ad1d711bf6d01b1e08b) > > Fault summary before full details > [tab] Device > > ![FDD Faults Device view with VAV and FCU fault counts by floor](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-faults-device-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=6b57690cabd73567e106fd266fca5c1d) > > Rows show device ID, fault count, floor, and duration. Tap a device to see aggregate metrics and its fault list. > > ![VAV\_101 device view with event totals and Temperature Greater than Setpoint fault](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-device-faults.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=a0449d3005eccb89f1bba9cd90fd492e) > > Device metrics and faults > [tab] Routine > > ![FDD Faults Routine view with sensor failure and temperature routines on Floor 2](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-faults-routine-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=c80bea8afc68aff28a4e45aaaad5dbbf) > > Tap a routine to see affected devices. Select a device row to open fault detail for that routine. > > ![Routine fault list entry for VAV\_209 stale discharge airflow sensor](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-routine-entry.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=32ed947a91737f889f3dc8b7492c8314) ## Fault detail The fault detail page shows status, metrics, and routine logic. ![Sensor Failure stale discharge airflow fault for VAV\_209 with 104 day duration](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-routine-detail.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=7616ef2c613dd0a77a4904297cffa555) Long-running sensor fault | Field | Description | | - | - | | `Status` | Open, closed, or other workflow state | | `Occurrences` | How many times the rule fired | | `Total Cost` | Cost rollup when configured | | `Area` | Spatial assignment | | `Last Update` | Latest activity timestamp | | `Average Duration` | Mean time in fault | | `Daily Avg Occurrences` | Trend density | | `Labels` / `Comments` / `Work Orders` / `Watchers` | Collaboration metadata | | `Description` | Full routine logic (`Show more`) | Expand `Possible Solution` for recommended actions. Change status from the dropdown when your role allows. ### Investigate with trends Open the more menu on the fault page: ![Fault menu with Info, Points Trend, Comments, Work Orders, Watchers, and Activity Log](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-detail-menu.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=2ed15adc6a8d22c94e97701c46371fc0) Select `Points Trend`, choose points on the device, then open `Trends View`. ![Points Trend for VAV\_208 with hot water valve points selected](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-points-trend.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=7e7fda007a96cfd356dab6799f3c5f44) ![Trends View for VAV\_208 zone temp and hot water valve percent with fault shading](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-trends-view.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=3a91c4160cadbb8c98936140b70ce9f5) Zone temperature and valve command over time Red shading on the chart marks the fault period. Correlate numeric trends with occupancy and valve state rows at the bottom. ### Collaboration and history Use the section dropdown below the fault title to switch between `Comments`, `Work Orders`, `Watchers`, and `Activity Log`. > [accordion] Comments > > ![Fault Comments for VAV\_101 with a sample comment Checking and Enter comment here field](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-comments.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=9a63905b9d95b52bf1947b5ac6dfe014) > > Add notes for your team in the comment thread. Each entry shows the author, timestamp, and message text. > [accordion] Work Orders > > ![Fault Work Orders empty state for VAV\_101 with Create Work Order button](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-work-orders.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=0335cb98387af04fdb9be09eeb056b4b) > > Create Work Order from fault > > `Work Orders` lists work orders linked to the fault. Tap `Create Work Order` when no record exists yet. > [accordion] Watchers > > ![Fault Watchers list for VAV\_101 with user checkboxes to subscribe to updates](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-watchers.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=7fabe8729a06cb4ecc062a7d7206c98d) > > Select users to watch the fault. Watchers receive notifications when status or activity changes. > [accordion] Activity Log > > ![Fault Activity Log for VAV\_101 showing comment Checking and status updated to IN\_PROGRESS](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-fault-activity-log.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=11fca527207f8c5427cd6796a9c1c335) > > Comments and status changes > > The log records comments, status updates, and other system actions with author and timestamp. ## Compare to web | Web capability | Mobile | | - | - | | Faults, device, and routine lists | Yes | | Fault metrics and description | Yes | | Points trend from fault | Yes | | Status updates | Yes (role-dependent) | | Bulk export | Use web | | Routine authoring | Use web | ## Next steps > [card] [FDD overview](/products/mobile-app/diagnostics/fdd-overview) > > Choose the right FDD screen for the job. > [card] [Events on mobile](/products/mobile-app/events/work-with-events) > > Filter, acknowledge, and investigate events. > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. # Event dashboards on mobile Source: https://docs.kodelabs.com/products/mobile-app/events/customize-event-dashboard Use Active and Historical FDD analytics cards to review open load and period trends on the KODE OS mobile app. Event dashboards show KPI cards and charts for FDD. They match [FDD dashboards](/products/fdd/dashboards) on the web. Open them from the `FDD Events` header when you need a summary view instead of only the event table. ## When to use Active vs Historical | Mode | Use for | Typical question | | - | - | - | | `Active` | Open events and incidents right now | “What is open, how urgent is it, and who owns it?” | | `Historical` | Closed or past items over a date range | “How busy was last week, and is acknowledgment getting slower?” | Both modes share the same chart types. The numbers change with the time window and whether items are still open. ## Open dashboards **1. Open FDD Events** Launch `FDD Events` from the building app launcher. **2. Select Active or Historical** Use the header dropdown. `Active` shows open-event KPIs. `Historical` shows period averages and trends. **3. Align filters** Use the `filter` icon so cards match the same area, priority, and date chips as the list. **4. Return to triage** Switch back to `Events` or `Incidents` in the header dropdown when you need to acknowledge or open a record. See [Events on mobile](/products/mobile-app/events/work-with-events). > [tab] Active > > `Active` puts summary cards at the top of `FDD Events`. > > ![Active FDD dashboard with Ongoing Events 2, Ongoing Incidents 1, High Priority Events 0, and secondary metrics for affected areas and acknowledgment](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-active-dashboard.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=3623200d15eadfd5961e0956ad4fab62) > > Summary KPI cards with 8-hour trends > > | Card | What it tells you | > | - | - | > | `Ongoing Events` / `Ongoing Incidents` | Current open count with an 8-hour trend | > | `High Priority` / `Escalated` | Critical load that needs attention first | > | `Affected Areas` / `Avg Duration` | Where impact is concentrated and how long items stay open | > | `Ack'ed Ratio` / `Avg Ack'ed Time` | How quickly the team acknowledges work | > > Scroll for charts that break down open events by area, routine, priority, device type, resolution, and assignee. > > ![Active assignees table with 2 events and 1 hour duration plus Floor 2 range control](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-active-assignees.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=8c4a1dcbda05ed9c8aa790c27c501051) > > Assignees and floor filter > > The `Assignees` table lists open events by owner. Use the floor range control to focus charts on a specific area. > > > [accordion] Active chart reference > > > > | Chart | Shows | > > | - | - | > > | `Affected Areas` | Open events by floor or zone | > > | `Routines` | Active events by fault name, with priority and average duration | > > | `Priority` | Share of events at each severity | > > | `Domains` | Fault category such as cooling or heating | > > | `Affected Device Types` | Equipment types involved (for example, FCU or VAV) | > > | `Relative Impact` | Event load across areas or systems | > > | `Resolution` | Acknowledged versus unacknowledged | > > | `Duration and Count Overview` | Event count compared with time open | > > > > ![Active Affected Areas bar chart showing Floor 2 with 2 events](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-active-affected-areas.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=6beae5e7ef0983ea666803f1840b5862) > > > > Affected areas by floor > > > > ![Active Routines chart for Temperature Less than Setpoint with Alert count 2 and average duration 1.21 hours](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-active-routines.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=3118083a14c4cd8380d8c8522a5772d9) > > > > Routines with severity breakdown > [tab] Historical > > `Historical` shows closed-period analytics at the top of `FDD Events`. > > ![Historical FDD dashboard with Daily Avg Events 55, Daily Avg Incidents 6, and acknowledgment metrics](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-historical-dashboard.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=f6ce00ff3e8f54226fe17c90ffe07ad2) > > Daily average KPI cards with previous-period trends > > | Card | What it tells you | > | - | - | > | `Daily Avg Events` / `Daily Avg Incidents` | Volume versus the prior period | > | `Daily Avg High Priority` / `Escalated` | Severity trends | > | `Daily Avg Affected Areas` / `Duration` | Scope and time to close | > | Daily average acknowledgment metrics | Acknowledgment performance over time | > > Scroll for charts that summarize closed events by area, routine, priority, device type, resolution, trends, and assignee. > > ![Historical Count and Duration Trend line chart peaking May 27 to 29 and Operation Daily Overview heatmap](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-historical-count-trend.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=80c73b7ce3b10770a1ad3989b38b219e) > > Count trend and daily operation heatmap > > `Count & Duration Trend` plots volume and time open across the selected date range. `Operation Daily Overview` compares events, acknowledgments, and escalations by day. > > > [accordion] Historical chart reference > > > > | Chart | Shows | > > | - | - | > > | `Affected Areas` | Closed events by floor or zone | > > | `Routines` | Closed events by fault name | > > | `Priority` | Share of events at each severity | > > | `Domains` | Fault category such as cooling or heating | > > | `Affected Device Types` | Equipment types involved | > > | `Relative Impact` | Event load across areas or systems | > > | `Resolution` | Acknowledged versus unacknowledged | > > | `Duration and Count Overview` | Event count compared with time open | > > | `Count & Duration Trend` | Volume and duration over the date range | > > | `Operation Daily Overview` | Events, acknowledgments, and escalations by day | > > | `Escalated Events` | When events escalated during the period | > > | `Assignees` | Closed events by owner with counts and duration | > > > > ![Historical Escalated Events timeline and assignees table with 2 events](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-historical-escalated-assignees.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=230790537844e7d1e9709c3a0edaf36a) > > > > Escalated events and assignees ## Customize layouts on web Dashboard composition, card types, and building-wide defaults are configured on the web. Mobile shows the published definitions for your role. ## Next steps > [card] [Events on mobile](/products/mobile-app/events/work-with-events) > > Filter, acknowledge, and investigate events. > [card] [FDD overview](/products/mobile-app/diagnostics/fdd-overview) > > Choose the right FDD screen for the job. # Events on mobile Source: https://docs.kodelabs.com/products/mobile-app/events/work-with-events Filter, acknowledge, and investigate FDD events and incidents from the KODE OS mobile app. Use `FDD Events` for real-time triage while you are on site. An **event** is one FDD finding on a device. An **incident** groups related events under one ID so you can see shared impact. Events match [Events](/products/fdd/events) on the web. ## Triage an event **1. Open FDD Events** Select `FDD Events` from the building app launcher. **2. Narrow the list** Tap the header `filter` icon for area, priority, and date chips such as `Last 7 Days`. Use the `history` icon to refresh when streaming is enabled for your site. **3. Open a row** Tap an event for a quick summary sheet, then `Event Details` for the full page. **4. Acknowledge and investigate** Acknowledge when your role and event assignment allow it. Use `Points Trend` to see sensor history, add comments, or create a work order when needed. ## Choose a view The header dropdown switches list and dashboard modes: ![FDD Events view menu with Events, Incidents, Active, and Historical options](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-events-view-menu.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=1fe95070d7efda27b26a0c517194c878) Events, Incidents, Active, and Historical | Mode | Purpose | | - | - | | `Events` | Individual FDD findings | | `Incidents` | Grouped events by incident ID | | `Active` | Open items with KPI cards—see [Event dashboards](/products/mobile-app/events/customize-event-dashboard#active-dashboard) | | `Historical` | Closed or past items with analytics cards | On the list screen, switch between `Events` and `Incidents` with the tabs under the header. ![FDD Events list tabs with Events selected and Incidents unselected](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-events-incidents-tabs.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=3b6c86ce2fb7cc92c7240d6bd1924704) Events and Incidents tabs > [tab] Events > > ![FDD Events list with Damper Fully Open and Temperature Greater than Setpoint alerts on VAV devices](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-events-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=dd7c3a60f3fc6f23979688e6a5965d9d) > > Each row shows: > > | Element | Description | > | - | - | > | Routine title | Fault name (for example, `Damper Fully Open for Long Periods`) | > | Alert badge | Priority such as `Alert` | > | Status | `Active` or duration (for example, `5 minutes`) | > | Device link | Equipment path such as `VAV_303` | > > Tap a row to open a quick summary sheet, then `Event Details`. > > ![Event sheet with area Floor 1, Occupancy command point, and Active end time](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-detail-sheet.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=20b1709c8b4056787737f7724a785737) > > Event summary sheet > > ### Event details > > The full event page includes metadata, diagnostics, and actions. > > ![Event details with building, device VAV\_303, priority Alert, and Unacknowledged control](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-event-detail.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=a67b1ff6286f37d1af881f479e221b6b) > > Use the **section** dropdown below the event title to switch panels. > > > [accordion] Info > > > > Shows status, duration, and the routine description (`Show more` expands the full text). > > > > ![Event info with Open status, duration, and routine description Show more](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-detail-info.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=9f41d4039406c70995b0b1e19354000b) > > > > Info tab with description > > > [accordion] Points Trend > > > > Select points on the device, then open `Trends View` to compare commands and sensors over time. > > > > ![Points Trend for VAV\_303 with discharge damper percent selected](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-points-trend.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=c222a9b1d9fba700a14afd0acd4cf649) > > > > ![Trends View for VAV\_303 discharge damper percent and occupancy command](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-trends-view.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=4030520936824879c96e2c6c32d4eccb) > > > > Trends for damper command and occupancy > > > [accordion] Work Orders > > > > Lists work orders linked to the event. Tap `Create Work Order` to open the create form when none exist yet. > > > > ![Event Work Orders empty state with Create Work Order button](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-work-orders.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=a36639bd34233cc528215fc0463d1044) > > > > ![Create Work Order form with Name, Data Source, Entity, and Action fields](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-create-work-order.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=d74c89ab95a6ab8099d1e01695289bcf) > > > [accordion] Comments > > > > Add notes for your team in the comment thread. > > > > ![Event Comments with Enter comment here field](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-comments.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=bbe0cd74338f5be6b5fd43df23fe066c) > > > [accordion] Historical > > > > Lists past occurrences of the same routine on the device. > > > > ![Historical occurrences list for Damper Fully Open with Active and past date ranges](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-occurrences.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=2990a980c302d95f9b838588d5e5cf26) > > > [accordion] Activity Log > > > > Lists system actions such as creation, merges, and notifications with timestamps. > > > > ![Event Activity Log showing This event/incident is created with timestamp May 28, 2026 9:11 AM](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-event-activity-log.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=2a9f70390f868553c26d1df53abd4401) > > > > Activity Log with creation timestamp > > Acknowledge events from `Unacknowledged` on the main event page. You need building access and the **Acknowledge FDD events** Write permission. When your role uses the default `AssignedInEvent` constraint, the event's notification policy must also assign the event to you. > [tab] Incidents > > ![FDD Events Incidents list showing incident IDs such as 260602-72408, affected fcu counts, and Alert priority badges](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-incidents-list.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=4f8dd88491d6d5839ce178bdb6621a18) > > Incidents list with Last 7 Days filter > > Rows show incident ID (for example, `260602-72408`), affected device count (`6 fcus`), and priority. Tap an incident for a summary sheet. > > ![Incident sheet with 11 events, Floor 1 area, and assignee name](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-incident-detail-sheet.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=0461d21729bbe84994f9f95cc85b4700) > > Incident summary before full details > > Select `Incident Details` for charts, table view, and activity logs. > > ### Incident details > > The incident page includes summary metrics, charts, and child events. > > ![Incident 260528-84496 with event count, status donut, and areas chart](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-incident-summary-cards.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=293ddb508aab6333d8ce63ec26e139a1) > > Scroll for device-type and timeline charts, then `Table View` for each child event and `Activity Logs` for merges and notifications. > > ![Incident affected vav donut and overall impact timeline](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-incident-device-types.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=8bacd7f6e8894d8888f1150090e5a367) > > Device types and timeline > > ![Incident table view with Damper Fully Open and Heating Stuck Open events plus activity log](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-fdd-incident-table-logs.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=54251ed3a79ddccb542cdb0d6f0945ee) ## FDD Reports from a device Open `FDD` from the [device](/products/mobile-app/building/devices#device-menu) `More` menu (or from an [area](/products/mobile-app/building/areas)). `FDD Reports` lists events and alarms for that equipment. > [tab] Active > > `Active` lists events and alarms that are currently open on the device. > > ![FDD Reports Active tab with Discharge Air Temp Low Limit fault and date range](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-fdd-reports.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=087c6437fbe8d1a53759689e83af6274) > > Active FDD reports for the device > > Each row shows the fault name and occurrence window. Tap a row to open the summary sheet, then `Event Details`. > [tab] Inactive > > `Inactive` lists events and alarms that are no longer active (history). ## Compare to web | Web capability | Mobile | | - | - | | Events and incidents lists | Yes | | Incident analytics and table view | Yes | | Event detail, points trend, comments | Yes | | Create work order from event | Yes (limited fields) | | Pause or resume streaming | Refresh and filters | | Export table | Use web | ## Next steps > [card] [Event dashboards](/products/mobile-app/events/customize-event-dashboard) > > Review Active and Historical FDD KPIs. > [card] [Manage FDD faults](/products/mobile-app/diagnostics/manage-fdd-faults) > > Inspect fault lifecycle metrics and trends. > [card] [FDD overview](/products/mobile-app/diagnostics/fdd-overview) > > Choose the right FDD screen for the job. # Use bookmarks on mobile Source: https://docs.kodelabs.com/products/mobile-app/get-started/bookmarks Pin devices and views with notes and reminders, then open them from the Bookmarks app on the KODE OS mobile app. Save the equipment or views you check most often so you can jump back to them without searching. Add a note and an optional push reminder to each bookmark. ## Open Bookmarks Open `Bookmarks` from the building app launcher (bottom sheet) or from profile flows. The launcher also lists other modules like `OSS`, `Work Orders`, and `Manual Meters` when published for your site. ![App launcher with Bookmarks checked and site card for KODE 1420 Office](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-bookmarks-app-launcher.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=d655b05367fce0343ccccd8e1ffd621e) Bookmarks selected in the app launcher Use the `sort` icon in the Bookmarks header to change list order. ## Bookmark list Each card summarizes a saved item: ![Bookmarks list showing AHU\_3 with building Floor 1 and note Check this AHU](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-bookmarks-list.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=a3b16a3bdd253e08e2c83eabddede54a) | Element | Description | | - | - | | Icon and status dot | Entity type (for example, device) and health indicator | | Name | Asset label such as `AHU_3` | | Timestamp | When the bookmark was created | | Building / Area | Site and floor context | | Note | Text you entered when saving | | Chevron | Opens the underlying device or view | Tap a card to jump directly to that asset. Use the notification bell when your site sends bookmark-related alerts. ## Create or edit a bookmark From a [device](/products/mobile-app/building/devices#device-detail), [system](/products/mobile-app/destinations/systems), or floor plan, tap the bookmark icon in the header. ![AHU\_3 device with red filled bookmark icon in the header](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-device-bookmarked.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=acef36678ba97149eccb3740147d6b0b) Filled bookmark on a saved device Configure the bookmark: ![Mark as Bookmark with note Check this AHU and Remind Me on Thu 28 May 4:07 PM](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-bookmark-note-reminder.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=0b134c7fff39dd82053235f3c64a2d66) Note and reminder | Field | Description | | - | - | | `Add Note` | Free-text context (for example, `Check this AHU`) | | `Remind Me` | Schedule a push reminder at a date and time | | `Save` | Store the bookmark | | `Cancel` | Discard changes | After you save, the header bookmark icon appears filled (red) on the asset. ## Remove a bookmark Open the saved item and tap the filled bookmark icon to remove it, or delete from the Bookmarks list when your role allows. ## Compare to web | Capability | Web | Mobile | | - | - | - | | Bookmark devices and views | Yes | Yes | | Notes and reminders | Yes | Yes | | Bookmarks app / list | Yes | Yes (app launcher) | ## Next steps > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. > [card] [Navigate the app](/products/mobile-app/get-started/navigation) > > Move between portfolio, site, and modules. > [card] [Customize experience](/products/mobile-app/get-started/customize-experience) > > Manage profile, theme, and organizations. # Customize your mobile experience Source: https://docs.kodelabs.com/products/mobile-app/get-started/customize-experience Manage profile, app appearance, help links, and organization switching in the KODE OS mobile app. The profile menu is where you personalize KODE OS on your device and switch between organizations your account can access. Building configuration—devices, routines, dashboards—stays in the web modules. ## Open profile and settings **1. Open your profile** From the [portfolio map](/products/mobile-app/portfolio/portfolio-and-sites), tap your initials in the top-left corner. You can also open profile from branded app headers (for example, `ZEN Estate`). ![Profile screen with user name, role, KODE OS context, and Settings list](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-settings-profile.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=848a39972adf56aaef2f7eda66026a62) **2. Review profile details** The header shows your name, role, and which app shell you are in. | Element | Description | | - | - | | `Name` | Launchpad display name (external link icon opens account details when enabled) | | `Role` | Permission tier (for example, SuperAdmin) | | `KODE OS` / `Switch app` | Jump to another branded mobile shell if your organization provides multiple apps | | `Version` | Installed build at the bottom (for example, 3.19.6) | | `Copyright` | KODE Labs legal footer | ## Settings options Under `SETTINGS`, each row opens a focused screen or browser view. | Option | Icon | What it does | | - | - | - | | `App Appearance` | Sun | Choose Light, Dark, or System theme | | `Share App` | Share | Send the store link so others can install KODE OS | | `Knowledge Base` | Help | Open documentation and help articles | | `Privacy Policy` | Shield | View the KODE Labs privacy policy | These options customize the app experience only. They do not change building data, schedules, or FDD rules. ### App appearance Tap `App Appearance` to set how KODE OS renders on your phone. ![App Appearance with Light, Dark, and System radio options and map previews](https://mintcdn.com/kodelabs/QV43LEddE2aJcRYU/images/mobile-app/kode-os-mobile-app-appearance.png?fit=max\&auto=format\&n=QV43LEddE2aJcRYU\&q=85\&s=6c676d80b266ae3797c92ad435b45ed7) Theme previews use the portfolio map and site list | Theme | Behavior | | - | - | | `Light` | Light map background and white module cards | | `Dark` | Dark map and list surfaces for low-light use | | `System` | Matches iOS or Android light/dark mode automatically (recommended) | Select a radio button to apply the theme immediately. Thumbnails show how `Sites` and module rows look in each mode. ### Share app, knowledge base, and privacy policy * `Share App` — opens the native share sheet with the public app link. * `Knowledge Base` — opens help content in the mobile browser. * `Privacy Policy` — opens the legal policy page managed by KODE Labs. ## Switch organization Use `Switch Organization` when your account has access to more than one organization. **1. Tap Switch Organization** From the profile screen, select `Switch Organization`. The organizations page opens in the web view at `accounts.kodelabs.com`. **2. Search or select an organization** Use the search field to filter organizations. Each card shows the organization name and workspace domain. ![Organizations list with search and Open Organization button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-organizations.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=6922ba01dae30c205cbf8e39011ff1eb) **3. Open Organization** Tap `Open Organization` on the card you need. KODE OS reloads with that organization's sites and apps. > [!NOTE] > > If you only see one organization, your administrator has not granted access to others. ## Log out Tap `Log out` to end your session on the device. You return to the workspace sign-in screen. Sign in again with the same workspace and credentials when you are ready. > [!TIP] > > Enable push notifications in iOS or Android system settings so KODE OS alerts reach you when the app is in the background. Open alerts from the portfolio map `bell` or module notification buttons. ## What you cannot change here | Task | Where to do it | | - | - | | User role or permissions | [Launchpad](/products/launchpad/client-organizations/users) | | Which apps appear per site | Launchpad app enablement | | Dashboard design | Web [Building BI](/products/building-bi/overview) | | FDD routines | Web [FDD](/products/fdd/overview) | ## Next steps > [card] [Bookmarks](/products/mobile-app/get-started/bookmarks) > > Pin devices and views with reminders. > [card] [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites) > > Use the map, site cards, and site switcher. # Navigate the KODE OS mobile app Source: https://docs.kodelabs.com/products/mobile-app/get-started/navigation Move between your organization, portfolio map, building site, and apps in the KODE OS mobile app. The mobile app has four levels of context: **workspace**, **organization**, **site**, and **module**. Most field work stays inside one site (building) at a time. A **workspace** is your company login domain. An **organization** is the account that owns your sites and apps. A **site** is one building. A **module** is an app such as Events, Devices, or Schedules. ```mermaid actions={false} theme={"theme":{"light":"github-light","dark":"github-dark"}} --- config: theme: neutral layout: dagre --- flowchart TB A["Workspace sign-in"] --> B["Organization"] B --> C["Portfolio map or module picker"] C --> D["Site context"] D --> E["Site module launcher"] E --> F["Module screen"] linkStyle 0 stroke:#00C853,fill:none linkStyle 1 stroke:#00C853,fill:none linkStyle 2 stroke:#00C853,fill:none linkStyle 3 stroke:#00C853,fill:none linkStyle 4 stroke:#00C853,fill:none ``` ## Organization context After [sign-in](/products/mobile-app/get-started/sign-in-and-workspace), you work in one organization at a time. That organization controls which sites, apps, and data you see. | Goal | Where to go | | - | - | | Switch organization | Profile → `Switch Organization`. See [Customize your experience](/products/mobile-app/get-started/customize-experience#switch-organization). | | Return to sign-in | Profile → `Log out` | Changing organization reloads the portfolio, site list, and every module. Bookmarks stay on the device but show data for the active organization only. > [!NOTE] > > If you only see one organization, your administrator has not granted access to others. ## Portfolio vs building apps KODE OS separates **portfolio** tools (all sites) from **building** apps (one site). | Level | How you open it | What it covers | | - | - | - | | **Portfolio** | Swipe up the bottom sheet on the map; pick `Sites`, `Dashboards`, `Building BI`, `FDD`, `FTT`, `Work Orders`, `Bookmarks`, or `Search` | All sites you can access, or cross-site views | | **Building** | Select a site, then open a module from the [site module launcher](#site-module-launcher) | One building (devices, events, schedules, and similar) | Use portfolio tools when you compare sites. Use the building launcher when you operate equipment or triage events for one building. Details for the map, sort, and search are in [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites). ## Site context When you enter a building module, the bottom bar shows the **active site** and `Switch Site`. | Action | What happens | | - | - | | `Switch Site` | Opens site selection; choosing another site reloads data for that building | | Stay on current site | All module screens share the same site until you switch | | Return to map | Swipe up `Portfolio` / `All Sites Overview` without signing out | Site context does not change your organization. It only changes which building’s points, events, and assets load. ## Site module launcher After you [enter a site](/products/mobile-app/portfolio/portfolio-and-sites#enter-a-site), swipe up the bottom sheet to open the **app launcher**. The header shows the site name, address, and `Switch Site`. ![Site module launcher with Systems, Areas, Devices, Points, and Data Sources icons and a list of Building BI, FDD Events, FDD Faults, FTT, Schedules, Trends, and OSS modules](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-site-module-launcher.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=e84dc8a43daf6e39f12a35fe1db63ec5) Site module launcher for KODE 1420 Office A checkmark shows the active module. Tap a row or icon to switch apps. > [accordion] Quick access icons > > | Icon | Module | Guide | > | - | - | - | > | `Systems` | Plant and equipment groupings | [Systems](/products/mobile-app/destinations/systems) | > | `Areas` | Floors, zones, and floor plans | [Areas and floor plans](/products/mobile-app/building/areas) | > | `Devices` | Equipment lists and device detail | [Devices](/products/mobile-app/building/devices) | > | `Points` | Point status, filters, and writes | [Points](/products/mobile-app/building/points) | > | `Data Sources` | Connectors and collection status | [Data sources](/products/mobile-app/building/data-sources) | > [accordion] Module list rows > > | Module | Guide | > | - | - | > | `Building BI` | [Building BI](/products/mobile-app/destinations/building-bi) | > | `FDD Events` | [Events](/products/mobile-app/events/work-with-events) | > | `FDD Faults` | [Manage FDD faults](/products/mobile-app/diagnostics/manage-fdd-faults) | > | `FTT` | [Functional testing](/products/mobile-app/diagnostics/functional-testing) | > | `Schedules` | [Schedules](/products/mobile-app/operations/schedules) | > | `Trends` | [Trends](/products/mobile-app/analytics/trends) | > | `OSS` | [Optimized start/stop](/products/mobile-app/operations/oss) | > > Your site may also publish `Work Orders`, `Manual Meters`, `Bookmarks`, or `Writable Points` when your role and product enablement allow. > [!NOTE] > > If a module is missing from the launcher, your role or site may not include it. AssetOps apps such as `Work Orders` require AssetOps to be enabled for the building. Confirm assignments with your administrator or in [Launchpad](/products/launchpad/channel-partners/product-enablement) on the web. ## Inside a module Most building apps share the same screen patterns. | Control | Typical use | | - | - | | `Back` (chevron) | Return to the previous list or parent screen | | Title | Current asset, event, work order, or view name | | Chat / comments | Collaboration on work orders, faults, or events when shown | | `More` (`⋯`) | Status history, edit, share, watchers, or module-specific actions | Detail screens often use horizontal tabs (for example, `Details`, `Attachments`, `Follow-ups`). Lists drill down to a record, then to sub-panels. Deep links from notifications open the target module when your role allows. Many module home screens show a blue **bell** for notifications. List screens may show a `+` button for create actions when your permissions allow. ## Portfolio sheet and notifications Swipe up the bottom handle labeled `Portfolio` or `All Sites Overview` from any building screen to return to the map or sites list. You keep your sign-in session and organization. From the sheet you can open another site, switch to portfolio modules, or [reorder modules](/products/mobile-app/portfolio/portfolio-and-sites#reorder-modules). Tap the blue **bell** on module home screens and the portfolio map to open `Notifications`. Alerts follow the same policies as KODE OS web for your role. Enable notifications in iOS or Android system settings if you declined the prompt earlier. ## Native screens and web views | UI type | Examples | | - | - | | **Native** | Portfolio map, device lists, trends, most module lists and detail tabs | | **In-app browser** | Sign-in, organization switcher, some profile links (Knowledge Base, Privacy Policy) | Web views load `accounts.kodelabs.com` or your identity provider during sign-in and organization switch. Use `Done` or back to return to native navigation. ## Quick reference | Goal | Start here | | - | - | | Change organization | [Customize your experience](/products/mobile-app/get-started/customize-experience#switch-organization) → `Switch Organization` | | Pick another building | Bottom `Switch Site` or portfolio map | | Open dashboards or cross-site FDD | Portfolio sheet → module row | | Command a point or device | Launcher → `Devices` or `Points` | | Triage an event | Launcher → `FDD Events` | | Field maintenance | Launcher → `Work Orders` | | Saved equipment | Launcher → `Bookmarks` | ## Next steps > [card] [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites) > > Use the map, site cards, and site switcher. > [card] [Customize experience](/products/mobile-app/get-started/customize-experience) > > Manage profile, theme, and organizations. > [card] [Mobile app overview](/products/mobile-app/overview) > > See how mobile covers KODE OS modules. # Sign in and workspace Source: https://docs.kodelabs.com/products/mobile-app/get-started/sign-in-and-workspace Install KODE OS, enter your workspace, and sign in with email or Microsoft SSO on iOS or Android. Use your organization workspace to open KODE OS on a phone or tablet. After you enter the workspace domain, the app opens a secure web sign-in view hosted on `accounts.kodelabs.com` or your identity provider. A **workspace** is your company login address, usually ending in `.kodelabs.com`. ## Install the app Download KODE OS from the [Apple App Store](https://apps.apple.com/om/app/kode-os/id1479690443) or [Google Play](https://play.google.com/store/apps/details?id=com.kodelabs.klp\&hl=en_US\&gl=US). ## Sign-in flow **1. Enter your workspace domain** Open KODE OS and type your workspace URL (for example, `yourcompany.kodelabs.com`). Tap `Continue`. ![Sign in to your workspace screen with workspace domain field and Continue button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-workspace-sign-in.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=e5e14d9d1e08b3a21f04f04fe1dd33f6) > [!NOTE] > > Some organizations use `kodemobile` on the first screen. Your administrator can confirm which workspace value to enter. **2. Allow the sign-in session** On iOS, confirm the system prompt so KODE OS can use `accounts.kodelabs.com` to sign you in. Tap `Continue`. ![iOS dialog asking to allow KODE OS to use accounts.kodelabs.com to sign in](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-sign-in-sso-prompt.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=9f699e51c54a461d63a1fa632bc2e692) iOS permission before the web sign-in view opens **3. Choose a sign-in method** The branded sign-in page loads in the web view. Options depend on how your organization is configured. > [tab] Email and password > > Use `Sign in with Email` when your organization allows local credentials. > > ![Sign in with email and password fields and Sign in with Email button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-sign-in-email.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=9e5f160e87a7b848b5508ad47d91ee9f) > > | Field / control | Action | > | - | - | > | `Email` | Enter your Launchpad email | > | `Password` | Enter your password (use the eye icon to show or hide) | > | `Forgot password?` | Open the password reset flow | > | `Sign in with Email` | Submit credentials | > | `Other sign in methods` | Return to alternate providers | > [tab] Microsoft SSO (Azure AD) > > **Single sign-on (SSO)** lets you use your work Microsoft account instead of a separate KODE password. When Azure AD is available, select `Sign in with Azure AD`. > > ![Sign in page with Sign in with Azure AD button managed by KODE Labs](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-sign-in-azure-ad.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=aa42045e262591c2521979a3d4cf0187) > > The page notes that sign-in is managed by KODE Labs. Use `Go Back` if you need to change workspace or method. > > Azure AD then opens the Microsoft sign-in experience. Enter your work email and select `Next`, or use `Sign-in options` for multi-factor authentication (MFA) or alternate methods. > > ![Microsoft online sign-in page for KODE Labs with email field and Next button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-sign-in-microsoft.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=53ddcd26b27f728429ebe7bbf7727511) > > Complete any MFA prompts your organization requires. When authentication succeeds, the web view closes and KODE OS loads your apps. **4. Select your organization** If your account belongs to more than one organization, choose the one you need on the [Organizations](/products/mobile-app/get-started/navigation#organization-context) screen. You can switch later from profile settings. ## Troubleshooting | Issue | What to try | | - | - | | Wrong workspace | Tap back, re-enter the correct `*.kodelabs.com` domain, and tap `Continue` again | | Sign-in web view blank | Close the app, check network or VPN, and retry | | SSO loop | Confirm your email is assigned to the organization in [Launchpad](/products/launchpad/get-started/workspaces-and-sign-in) | | Forgot password | Use `Forgot password?` on the email sign-in page or reset from your workspace URL in a browser | | No mobile access | Ask your administrator to verify your user and app entitlements | ## Next steps > [card] [Navigate the app](/products/mobile-app/get-started/navigation) > > Move between portfolio, site, and modules. > [card] [Customize experience](/products/mobile-app/get-started/customize-experience) > > Manage profile, theme, and organizations. # KODE glossary Source: https://docs.kodelabs.com/products/mobile-app/glossary Definitions of common KODE Labs terms across Cloud BMS, Launchpad, Building BI, AssetOps, EnerG, FDD, FTT, and related products. Filter by product Glossary product filters Lookup definitions for common KODE Labs terms. Jump to a letter, or search this page. Where a related guide exists, the term links to that documentation. For equipment and point abbreviations, see [Smart Building terminology](#smart-building-terminology). ## A ### Accruals EnerG In EnerG, estimates of usage or cost for months that lack final bills. EnerG borrows prior-year shapes, spreads usage across calendar months, and closes month-end gaps until utilities post final reads. See [Key concepts](/products/energ/get-started/key-concepts). ### Acknowledgement FDD Recognizing and responding to an alarm or event so the issue can be tracked to resolution. See [Events](/products/fdd/events). ### Active FDD An alarm or event status that means the point has not returned to its normal state. Active events typically appear highlighted until the condition clears. See [Events](/products/fdd/events). ### Activity log Points A record of user-initiated adjustments and commands to equipment settings, including setpoint and variable changes with reasons and priorities. See [Commanding points](/products/kode-os/points/commanding-points). ### Adapter OSS In [Optimized Start/Stop (OSS)](/products/kode-os/oss), the adapter customizes machine-learning optimization for HVAC systems by specifying devices and parameters such as zone temperature, cooling and heating setpoints, run status, and occupancy mode. ### Aggregated table Building BI In Building BI, a table widget that folds source rows into one line per group and computes metrics such as sum, max, count, or last for each group. ### Alarm FDD A device-reported occurrence that needs attention or resolution by building management. See [Events](/products/fdd/events). ### Alert FDD An alarm priority that ranks urgency and helps determine response order. See [Events](/products/fdd/events). ### Alert Center EnerG In EnerG, a portfolio list of data-quality issues for utility meters such as gaps, overlaps, duplicates, and late or missing bills. See [Alert Center](/products/energ/data-quality/alert-center). ### API Integrations API stands for Application Programming Interface. An API is a defined way for two software systems to exchange data and commands over a network. Instead of a person clicking through a vendor portal, KODE OS calls the vendor's API to discover devices, collect readings, or send actions. Most KODE OS integrations use REST APIs over HTTPS. Some use SOAP, webhooks, MQTT, SDKs, or building protocols such as BACnet and Modbus. See [What are Integrations?](/products/integrations/get-started/introduction) and the [Integrations catalog](/products/integrations/catalog). ### API Catalog Integrations The in-product library of supported integrations inside Cloud BMS. Open `Data Sources`, then `API Catalog`, to search by vendor or system type and add a connector. The docs [Integrations catalog](/products/integrations/catalog) mirrors that library for browsing outside the product. ### Arcadia EnerG An automated utility connection that signs in to provider portals and retrieves bills, usage, accounts, meters, and statements for EnerG on a schedule. See [Arcadia](/products/energ/data-sources/arcadia). ### Archived FTT In [FTT](/products/ftt/overview), archived test results mark a wrong or unnecessary routine so the data stays available but is treated as non-informative. See [Test results](/products/ftt/test-results). ### Area AssetOpsCloud BMS A space within a floor of a building that one or more building-system components affect. See [Areas](/products/kode-os/areas). In AssetOps, an area is also a building location (room, floor, or common space) used to place assets or target work orders when no asset is selected. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Assignees FDD In an [FDD notification policy](/products/fdd/notification-policies), assignees are roles or users selected to receive notifications, with methods and escalation timings you can customize by role. ### Asset AssetOps In AssetOps, a physical device or equipment item in a building that needs monitoring, maintenance, or operational oversight. See [Assets](/products/assetops/quickstart/assets). ### Asset category AssetOps In AssetOps, the required top-level grouping for every asset: Equipment, Architectural, or Furniture. Distinct from a work order category. See [Assets](/products/assetops/quickstart/assets). ### Asset discovery AssetOps In AssetOps, the building-level process to import and onboard assets from a data source, including discovery runs, field mapping, and matching. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset linking AssetOps In AssetOps asset discovery, merging newly discovered assets with existing building assets so one physical device keeps a single record. See [Asset discovery](/products/assetops/assets/asset-discovery). ### Asset status AssetOps In AssetOps, the lifecycle state of an asset record: Active, Out of Service, or Decommissioned. See [Assets](/products/assetops/assets/assets). ### Asset type AssetOps In AssetOps, a finer grouping under an asset category (for example AHU, VAV, or boiler). Asset types also scope task templates and schedules. See [Assets](/products/assetops/quickstart/assets). ### AssetOps AssetOps The KODE CMMS product for asset and maintenance operations across a portfolio, including work orders, schedules, assets, and shared resources. See [AssetOps overview](/products/assetops/quickstart/overview). ### Audit DevicesCloud BMS A view of real-time and historical data for devices and points, used to monitor device status, point integrity, and building areas. See [Devices](/products/kode-os/devices/devices) and [Trends](/products/kode-os/trends). ### Authentication logs Launchpad A security feature for Owners and Admins that lists account access details for workspace members. Individuals can view logs for their own account. See [Security settings](/products/launchpad/get-started/security-settings). ### Auto-fail AssetOps In AssetOps, a schedule setting that marks generated work orders as failed if they are not completed within a configured number of days after the due date. See [Schedules](/products/assetops/schedules/schedules-overview). ### Auto-refresh Building BI In Building BI, a per-dashboard setting that controls how often the dashboard re-queries data. ## B ### Baseline EnerG In EnerG, a historical reference window—usually 12 or 24 months—that you measure savings, intensity, and compliance against. You need 12 consecutive months of complete billed data before a baseline qualifies. See [Key concepts](/products/energ/get-started/key-concepts). ### Batch update DevicesPoints Making simultaneous changes to multiple devices or points instead of updating them one by one. See [Device batch update](/products/kode-os/devices/device-batch-update) and [Points batch update](/products/kode-os/points/points-batch-update). ### BACnet Integrations BACnet stands for Building Automation and Control Network. It is a standard protocol used by building systems to communicate with controllers, meters, and HVAC equipment over IP or serial networks. Some KODE OS integrations discover and collect BACnet objects dynamically. See [What are Integrations?](/products/integrations/get-started/introduction). ### BigQuery Building BI A Building BI database backend used as a near-real-time backup and home for internal module tables such as FTT, FDD, and OSS. Virtual tables cannot be created on BigQuery in Building BI. ### BIM model Graphics A digital graphic representation of a building that integrates layouts, system components, and device graphics for design and management. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Bool point Points A binary point state such as ON/OFF or TRUE/FALSE. See [Points](/products/kode-os/points/points). ### Breakdown dimension Building BI In Building BI, a secondary dimension that splits a chart series, typically as the legend. ### Budget planning EnerG In EnerG, a building workflow to create, edit, and activate annual energy budgets, then track predicted versus actual spend and variance. See [Budget planning](/products/energ/finance/budget-planning). ### Building Cloud BMS A site integrated in Cloud BMS. See [Sites and map](/products/kode-os/sites-and-map). ### Building BI Building BI The analytics and visualization module in Cloud BMS for interactive dashboards, charts, collections, and portfolio insights. Building BI consolidates data from other KODE modules into a single pane of glass. See [Building BI](/products/building-bi/overview). ### Building level AssetOpsBuilding BI A product scope limited to a single building. In Building BI, data is pre-filtered to that site for day-to-day operations. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, building-level work covers day-to-day work orders, schedules, assets, teams, routing, and local completion-policy overrides. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ## C ### Calculated column Building BI In Building BI, single-row custom logic on a data source that creates a new virtual field from that row's values. It does not aggregate across rows. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated metric Building BI In Building BI, a multi-row aggregation such as SUM, AVG, or COUNT that recalculates based on chart grouping. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calculated URL Building BI In Building BI, a calculated field that turns data into an internal Cloud BMS or external navigation link. See [Calculated fields](/products/building-bi/reference/calculated-fields). ### Calendar month alignment EnerG In EnerG, spreading each billing period across calendar months using average daily consumption so irregular bill windows align for comparisons and closes. See [Key concepts](/products/energ/get-started/key-concepts). ### Calendar schedule Integrations In Integrations, a schedule type for exceptions and one-time events such as holidays, maintenance windows, and temporary overrides. Calendar schedules override the regular weekly pattern for specific dates or ranges. See [Schedules](/products/integrations/capabilities/schedules). ### Canvas type Building BI In Building BI, the dashboard layout mode. A Fixed canvas locks a set width for stable rendering; a responsive or auto canvas adjusts to the viewer's screen. ### Capital planning EnerG In EnerG, a building workflow to model energy conservation investments through baselines, rates, measures, scenarios, and projected savings. See [Capital planning](/products/energ/sustainability/capital-planning). ### Carbon emissions intensity EnerG In EnerG, site or portfolio emissions tied to area, occupancy, or revenue, depending on the reporting standard. See [Key concepts](/products/energ/get-started/key-concepts). ### Catalog Integrations A repository of available APIs, including endpoints, authentication methods, versioning, and usage limits. In KODE documentation, the Integrations catalog lists supported connectors by system type. See the [Integrations catalog](/products/integrations/catalog) and [API Catalog](#api-catalog). ### Category AssetOps In AssetOps, a portfolio-level broad grouping for work orders (for example HVAC or plumbing), used with issue types for routing. See [Categories](/products/assetops/resources/categories). ### Change of value (COV) Building BI In Building BI time-series sources, a polling pattern that writes a new row only when a value changes beyond a threshold, with a maximum interval even when the value is unchanged. ### Chart template Building BI In Building BI, a reusable template that captures a single chart or widget. Apply it from the chart library while editing a dashboard. See [Templates](/products/building-bi/templates). ### Circuit view Cloud BMS A graphical overview of system device placement and interactions within major systems. See [Systems](/products/kode-os/systems). ### ClickHouse Building BI The Building BI database backend optimized for high-volume real-time sensor data. It powers the Point Time Series Real-Time table. ### Collaborator Building BI In Building BI, a specific user granted edit access to a dashboard. Collaborator access is user-based, not role-based, and cannot remove the original owner. See [Collections](/products/building-bi/collections#collaborator-access). ### Collection Building BIIntegrations In Building BI, a role-based grouping of dashboards, similar to a folder. A dashboard must belong to a published collection before most users can see it. One dashboard can belong to multiple collections without duplication. See [Collections](/products/building-bi/collections). In Integrations, collection means gathering sensor or non-sensor data from a connector after devices and points are registered. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection mode Integrations How Cloud BMS interprets data returned by an integration entity. Modes are Snapshot (current state each cycle), Delta (only changes since the last cycle), and Historical (a bulk log of past values). Vendor pages list the mode in the Overview property table. See [Data collection](/products/integrations/capabilities/data-collection). ### Collection template Building BI A reusable Building BI template that captures an entire collection, including its dashboards and data-source dependencies. See [Templates](/products/building-bi/templates). ### Connector Integrations The configured connection from Cloud BMS to one external system. Connectors live on the `Data Sources` page. You add one from the API Catalog, enter credentials, enable entities, and set polling where needed. Older UI labels may say datasource; prefer connector in documentation. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Quickstart](/products/integrations/get-started/quickstart). ### Color palette Building BI In Building BI, an organization-defined set of complementary colors managed in Settings and applied to categorical chart series. ### Color scheme Building BI In Building BI, a KODE Labs-designed set of complementary colors for categorical chart values. Unlike a color palette, schemes are predefined by KODE rather than managed by the organization in Settings. ### Column Building BI In Building BI, a field drawn from a data source. A column may be native to the source or calculated. See [Data sources](/products/building-bi/data-sources). ### Completion policy AssetOps In AssetOps, a rule that must be satisfied before a work order can move to For review or Complete—for example all tasks Done or N/A, time logged, or notes on non-compliance. See [Completion policies](/products/assetops/quickstart/settings-completion-policies). ### Completion SLA AssetOps In AssetOps, the time target on a priority level for finishing a work order after it is created. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Confidence band Building BI In Building BI, a shaded uncertainty range drawn around a line-chart series, defined by lower and upper boundary fields. ### Configuration FDD FDD settings for events, notifications, and incident priorities. See [FDD configuration](/products/fdd/configuration). ### Conservation measure EnerG In EnerG Capital Planning, an individual energy or resource conservation project with savings, capital cost, and related inputs. Measures can be bundled into scenarios. See [Capital planning](/products/energ/sustainability/capital-planning). ### Corrective maintenance AssetOps In AssetOps, maintenance that fixes faulty or non-functioning assets. It is typically tracked with generic work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Critical FDD An alarm priority for the highest urgency. See [Events](/products/fdd/events). ### Cross-filter Building BI In Building BI, a temporary filter created by clicking a chart segment. The selection applies to other widgets on the page within the filter's scope. See [How filtering works](/products/building-bi/concepts/how-filtering-works). ### Custom view Building BI In Building BI Deployment Manager, a site-local editable copy of a deployed dashboard. Custom views stop receiving predefined auto-sync updates. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ## D ### Dashboard filter Building BI In Building BI, a filter that affects the entire dashboard at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Dashboard template Building BI In Building BI, a reusable template that captures an entire single dashboard. It is the usual starting point when applying a full dashboard layout elsewhere. See [Templates](/products/building-bi/templates). ### Dashboard view Building BICloud BMS A visual overview of system points presented on charts. See [Systems](/products/kode-os/systems) and [Building BI dashboards](/products/building-bi/dashboards). ### Dashboards Building BIFDD Interfaces that display key metrics, visualizations, and performance indicators. In Building BI, a dashboard is a canvas with one or more pages of widgets and charts. Building BI replaces the legacy Cloud BMS `Dashboard` module. See [Building BI dashboards](/products/building-bi/dashboards) and [FDD dashboards](/products/fdd/dashboards). ### Data bar Building BI In Building BI, an in-cell horizontal bar in a table that shows the magnitude of a numeric value. On a pivot table, bars appear only at the lowest hierarchy level. ### Data capture rate EnerG In EnerG waste analytics, how completely reported waste covers the streams you expect to track. See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Data completeness EnerG In EnerG, a 0–100% score of billed coverage from each meter's service start through today. Missing bills, gaps, or overlaps lower the score. See [Data completeness](/products/energ/data-quality/data-completeness). ### Data refresh interval Building BI In Building BI, a per-chart setup setting that controls how often that widget queries for new data. ### Data source Building BIEnerGIntegrationsCloud BMS In Cloud BMS integrations, a data source is the configured connection to an external system. The preferred term is connector. In the product UI, connectors appear on the `Data Sources` page. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data sources](/products/kode-os/data-sources). In [Building BI](/products/building-bi/data-sources), a data source is a dataset—table or view—that charts draw from. It is the origin of columns, metrics, and calculations, and is separate from Cloud BMS integration connectors. In EnerG, a data source is any path that brings utility or meter data into the product, such as Arcadia, CSV, manual entry, or KODE OS interval meters. See [Portfolio data sources](/products/energ/analytics/portfolio-data-sources). ### Deficiency AssetOps In AssetOps, an inspection finding or linked deficiency recorded against a work order when applicable. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Deployment audit FTT A review of integration or FTT deployment progress across all buildings, with status insights and remaining tasks. See [FTT deployment](/products/ftt/deployment). ### Deployment manager Building BI A portfolio-only Building BI tool that deploys a dashboard or collection to many buildings and manages sync of predefined copies. See [Deployment manager](/products/building-bi/deployment-manager). ### Device Devices An intelligent component of a building system that controls a function for one or more areas (for example, an AHU or VAV). See [Devices](/products/kode-os/devices/devices). ### Device types Devices Categories of devices integrated to manage and monitor building systems. See [Devices](/products/kode-os/devices/devices) and [Device templates](/products/kode-os/devices/device-templates). ### Dimension Building BI In Building BI, a column used to categorize or group data on a chart, such as on the X-axis. ### Delta Integrations In Integrations, a collection mode that stores only value changes since the last collection cycle. Delta reduces data volume for controllers that report change-of-value updates. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Discover schedules IntegrationsCloud BMS Identifying schedules for connected devices so you can create, modify, and synchronize them between Cloud BMS and the source system. See [Schedules](/products/kode-os/schedules) and [Schedules (Integrations)](/products/integrations/capabilities/schedules). ### Discovery IntegrationsCloud BMS The process of finding equipment from a data source or connector and importing its entities into Cloud BMS. See [Device discovery](/products/kode-os/device-discovery). In Integrations, discovery is a user-initiated query against a connector that lists devices, points, schedules, and assets for registration. Not every integration supports discovery. Webhook-only and MQTT integrations often skip it. See [Discovery](/products/integrations/capabilities/discovery). ### Diversion rate EnerG In EnerG, the percentage of total waste routed away from landfill (diverted waste divided by total waste). See [Waste dashboards](/products/energ/analytics/portfolio-dashboards-waste). ### Down device Devices A device that is offline or unable to communicate with the service. See [Devices](/products/kode-os/devices/devices). ### Draft Building BI In Building BI, a private, editable version of a dashboard that viewers do not see until you publish. See [Dashboards](/products/building-bi/dashboards). ### Drill-down Building BI In Building BI, stepping into more granular layers within one chart by expanding a configured hierarchy. The same widget shows more detail. ## E ### Dynamic API Integrations An integration pattern where the external system does not expose a fixed list of device and point types. Objects appear at runtime during discovery. Niagara and many BACnet servers behave this way. After discovery, you often map each object to ontology manually in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Emission factor EnerG In EnerG, a factor in the Emissions Factor Library that drives carbon calculations, including methodology, GHG scope, service type, and geography or grid. Active factors apply to reports. See [Emission factors](/products/energ/analytics/portfolio-emissions-emission-factors). ### EnerG EnerG The KODE Labs energy and sustainability module for centralizing utility data, benchmarking buildings, and connecting targets, capital planning, and finance reporting. See [EnerG introduction](/products/energ/get-started/introduction). ### Energy Use Intensity (EUI) EnerG In EnerG, annual energy divided by conditioned floor area. EUI is the primary energy benchmark across buildings. See [Benchmarking](/products/energ/analytics/benchmarking). ### Entity (integrations) Integrations A category of data a connector can collect or manage. Common entities include Point History, Alarm, Audit Log, Work Order, Booking, EV Charging, and Schedule Sync. During connector setup, entity enablement toggles which entities the connector collects. See [Managing connectors](/products/integrations/get-started/managing-connectors) and [Data collection](/products/integrations/capabilities/data-collection). ### Event FDD A device-reported occurrence for attention or resolution by building management. See [Events](/products/fdd/events). ### Event class FDD Categories that group notification and monitoring configuration for event types such as communication, HVAC, fire, or generator. See [FDD configuration](/products/fdd/configuration). ### Export Building BICloud BMS In Trends, retrieving device history data in CSV format for analysis or sharing, based on time intervals and aggregation. See [Trends](/products/kode-os/trends). In Building BI, export PDF captures of dashboards, pages, or widgets. For table-like widgets, export to CSV for analysis. ### External communication AssetOpsFDDCloud BMS Configuring and sending automated work orders to a CMMS when alarms trigger in Cloud BMS. See [FDD work orders](/products/fdd/work-orders) and [AssetOps work orders](/products/kode-os/assetops/work-orders). ## F ### Fault Detection and Diagnostics (FDD) FDD A method for identifying device conditions from broader analysis rather than simple instantaneous alarms. See [FDD overview](/products/fdd/overview). ### Favorites Building BI In Building BI, a left-navigation section that lists dashboards or collections the user has starred. A favorite stays in the main list as well. ### Field permissions AssetOps In AssetOps, portfolio settings that lock or restrict editing of work order fields by work type, status, or time. See [Field permissions](/products/assetops/quickstart/settings-field-permissions). ### Files Graphics Uploaded documents—typically floor plans or device and system files—used in Graphics to create custom visuals. See [Graphics](/products/kode-os/graphics/graphic-tool). ### Filter scope Building BI In Building BI, the set of widgets and filters a given filter, slicer, or cross-filter influences. Use scopes to exclude items so not everything on the page is affected. ### Fleet emissions EnerG In EnerG, company vehicle fuel and distance activity for Scope 1 mobile combustion reporting. See [Fleet emissions](/products/energ/analytics/portfolio-emissions-fleet-emissions). ### Focus mode AssetOps In AssetOps, a work order list preset that shows only urgent items: SLA breached, SLA or timing warnings, and high priority. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Follow-up work order AssetOps In AssetOps, a child work order created from a parent to continue work. Completion policies can require one when a task needs further action. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Forecasting EnerG In EnerG, projecting future or near-term energy consumption from trained models and interval history, often using weather drivers. See [Forecasting](/products/energ/energy-modeling/forecasting). ### Fugitive emissions EnerG In EnerG, refrigeration and air-conditioning refrigerant loss tracked for Scope 1 fugitive reporting. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Functional Testing Tool (FTT) FTT Automates inspection and verification of building equipment for continuous commissioning and remote validation. See [FTT overview](/products/ftt/overview). ## G ### Generic work order AssetOps In AssetOps, the work order type used for corrective maintenance that is not generated from a schedule. See [Work orders](/products/assetops/quickstart/work-orders). ### Global template Building BI In Building BI, a KODE Labs-curated template visible to every workspace and read-only to organization admins. See [Templates](/products/building-bi/templates#global-templates). ### Global warming potential (GWP) EnerG In EnerG, the multiplier for a refrigerant used with quantity lost to calculate CO₂e for a fugitive event. See [Fugitive emissions](/products/energ/analytics/portfolio-emissions-fugitive-emissions). ### Graphics Graphics The Cloud BMS tool for creating and customizing system graphics, device graphics, and floor plans, including Smart Markers and zone drawing. See [Graphic tool](/products/kode-os/graphics/graphic-tool), [Floor plans](/products/kode-os/graphics/floor-plans), [System graphics](/products/kode-os/graphics/system-graphics), and [Device graphics](/products/kode-os/graphics/device-graphics). ## H ### Heating and cooling degree days EnerG In EnerG, a measure of how much outdoor weather departs from configured base temperatures each day. Higher values indicate greater heating or cooling demand. See [Building information](/products/energ/buildings/building-information). ### Historical Integrations In Integrations, a collection mode that ingests a complete log of past values over a time range from the external system. Use it for backfill, energy meter history, and some audit logs. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### History Cloud BMS A chronological record of a device's past performance metrics, such as temperature trends. See [Trends](/products/kode-os/trends). ### History logs Cloud BMS Previous versions of schedules saved in Cloud BMS that you can view, manage, and restore. See [Schedules](/products/kode-os/schedules). ### Hourly Aggregated Building BI In Building BI, a reduced-frequency Point Time Series polling structure that returns aggregated values for each point for each hour. ## I ### Icons Graphics Visual symbols for device types or values on a system graphic or floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Idle timeout Launchpad The period of user inactivity after which the system logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Incidents FDD A recorded issue with an incident ID, associated with buildings and routines, managed in sortable tables and detail views. See [Faults](/products/fdd/faults) and [Events](/products/fdd/events). ### Inspection AssetOps In AssetOps, a proactive maintenance type for assessing condition or compliance. Inspections are delivered through scheduled work orders, with subtypes for Assets, Area, or General. See [Work orders](/products/assetops/quickstart/work-orders). ### Interval meter EnerG In EnerG, a meter that records high-frequency usage such as hourly or 15-minute reads for granular charts, forecasting, and Option B M\&V. Distinct from monthly utility bill meters. See [Meters](/products/energ/buildings/meters). ### IPMVP EnerG International Performance Measurement and Verification Protocol. EnerG aligns with IPMVP approaches for quantifying energy savings and supports Option B and Option C. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option B EnerG In EnerG, an M\&V path that models savings at the meter or system level when metering isolation is strong. See [Energy modeling](/products/energ/concepts/energy-modeling). ### IPMVP Option C EnerG In EnerG, an M\&V path that analyzes whole-building energy use when boundary-level billing data represents performance. See [Energy modeling](/products/energ/concepts/energy-modeling). ### Issue type AssetOps In AssetOps, a specific problem or task under a category that drives building routing. See [Categories](/products/assetops/resources/categories). ## K ### KODE OS data source EnerG In EnerG, the connector that pulls mapped KODE OS interval points for Interval Trends, M\&V, and forecasting. See [KODE OS data source](/products/energ/data-sources/kode-os-data-source). ## L ### Last value Building BI In Building BI, a virtual Point Time Series source that returns only the most recent reading per sensor. Use it for current-state views across misaligned poll times. ### Layers Graphics Floor-plan layers that filter views by device or sensor type. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lead member AssetOps In AssetOps, the team member designated as the team lead who coordinates work for that building team. See [Teams](/products/assetops/resources/teams). ### Legend Graphics Controls that show or hide the icon legend on a floor-plan widget. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Lockout settings Launchpad Temporarily restrict account access after a set number of failed login attempts, including retry count and lockout duration. See [Security settings](/products/launchpad/get-started/security-settings). ### Logged time AssetOps In AssetOps, hours recorded against a work order for labor tracking. Completion policies can require logged time. See [Work orders](/products/assetops/work-orders/work-orders-overview). ## M ### Marked area Building BI In Building BI, a shaded background zone on a chart that highlights an axis range, such as an acceptable operating band or fault threshold. ### Marker icons Graphics The visual representation and styling of markers on floor plans. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Markers Graphics Customizable visual elements on floor plans (size, color, text, style) that represent points and devices. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Measurement and verification (M\&V) EnerG In EnerG, confirming that savings from energy projects are real using agreed methods and data. EnerG trains models that estimate adjusted baseline use and support savings calculations. See [M\&V models](/products/energ/energy-modeling/mv-models). ### Meter EnerG In EnerG, a tracked device or account boundary—whole-site or below the whole-site boundary—with service start and end dates that control which bills count. Types include utility, interval, or both. See [Meters](/products/energ/buildings/meters). ### Meter comparison EnerG In EnerG, a data-quality check that compares utility bill meters to interval meter readings for the same service type and flags deviation beyond a threshold. See [Meter comparisons](/products/energ/data-quality/meter-comparisons). ### Metric Building BI In Building BI, a pre-aggregated value such as SUM, AVG, or COUNT available from a data source for charts. See [Data sources](/products/building-bi/data-sources). ### Metric filter Building BI In Building BI, a filter based on an aggregation result—for example, only devices where the sum of alarms is greater than 10. See [Filter options](/products/building-bi/reference/filter-options). ### MFA Launchpad Multi-factor authentication requires a second factor, such as an authenticator app or SMS code, in addition to a password. See [Security settings](/products/launchpad/get-started/security-settings). ### Modbus Integrations A common industrial and building automation protocol for reading and writing registers on meters, controllers, and other field devices. Modbus can run over serial links (RS-485) or TCP/IP. See [What are Integrations?](/products/integrations/get-started/introduction). ### MQTT Integrations MQTT stands for Message Queuing Telemetry Transport. It is a lightweight publish/subscribe messaging protocol designed for constrained devices and low-bandwidth networks. Devices publish messages to topics on an MQTT broker. KODE OS subscribes to those topics and processes readings as they arrive, instead of polling on a timer. Key ideas: the broker routes messages; a topic is a hierarchical path such as `building/floor1/sensor/temperature`; QoS (Quality of Service) controls delivery guarantees (0 at most once, 1 at least once, 2 exactly once). See [MQTT integrations](/products/integrations/capabilities/mqtt). ### Mobile layout Building BI In Building BI, a mobile-specific dashboard view for reorganizing and resizing widgets on small screens. ### My Dashboards Building BI In Building BI, the private list of dashboards the current user can edit. Access is user-based, not role-based, and this list is not publishable as a collection. See [Collections](/products/building-bi/collections#my-dashboards). ## N ### Navigation widget Building BI In Building BI, a button widget that jumps the viewer to another page in the same dashboard. It does not carry filter context the way drill-through does. ### Non-sensor data Integrations In Integrations, structured building data that is not generated by a physical sensor. Examples include alarms, audit logs, work orders, bookings, and EV charging sessions. Contrast with sensor data and Point History. See [Data collection](/products/integrations/capabilities/data-collection). ### Notifications FDD Timely messages to designated recipients based on rules and preferences during events. See [Notification policies](/products/fdd/notification-policies). ## O ### Ontology DevicesIntegrations A structured framework that standardizes how buildings, devices, and equipment are represented by operations and function. See [Device templates](/products/kode-os/devices/device-templates). In Integrations, ontology maps vendor-specific device and point names to Cloud BMS standard types after discovery. Different vendors may call the same sensor `temp_sensor`, `temperature probe`, or `TS01`. Ontology lets you operate on a Temperature Sensor with a Temperature point regardless of the source name. You usually finish mapping in Cloud BMS. See [What are Integrations?](/products/integrations/get-started/introduction). ### Optimized Start Stop (OSS) OSS Starts equipment just in time so zones meet heating and cooling setpoints at the right moment, using adaptive machine learning per building. See [OSS](/products/kode-os/oss). ### Organization template Building BI A Building BI template owned by one organization. Admins (or users with Manage Templates) can edit it, and it is visible only inside that organization. See [Templates](/products/building-bi/templates#organization-templates). ### Owner Building BI In Building BI, the user who created a dashboard. Some actions, such as changing allowed IP addresses on a shared link, require dashboard ownership. See [Dashboards](/products/building-bi/dashboards). ## P ### Page Building BI In Building BI, a tab within a dashboard that holds its own widgets and queries. Splitting analytics across pages can improve load performance. See [Dashboards](/products/building-bi/dashboards). ### Page filter Building BI In Building BI, a filter that affects an entire dashboard page at once. You can allow users to change the filter while viewing. See [Filter options](/products/building-bi/reference/filter-options). ### Page template Building BI A reusable Building BI template of a single dashboard page, including charts and layout. Applying it inserts a new page. See [Templates](/products/building-bi/templates). ### Parameters FTT In FTT, customizable workflow settings you can adjust without editing the workflow logic itself. See [Workflows](/products/ftt/workflows). ### Password settings Launchpad Settings such as complexity, expiry, password history, and related session controls. See [Security settings](/products/launchpad/get-started/security-settings). ### PDF export Building BI In Building BI, a one-time snapshot of selected dashboard pages as a PDF file. ### Physical data source Building BI In Building BI, a materialized table from the KODE backend or a metric pipeline. Rows already exist in storage. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Pivot table Building BI In Building BI, a table widget that groups by a hierarchy on rows and spreads another dimension's values across columns, with an aggregated value in each cell. ### Placement Graphics Positioning equipment in locations on a building floor plan. See [Floor plans](/products/kode-os/graphics/floor-plans). ### Point Smart Building A read or write function within a device, such as a temperature setpoint, current temperature, or on/off state. See [Points](/products/kode-os/points/points). ### Point history Integrations In Integrations, the entity that stores time-series sensor readings collected from device points. Point History is the usual sensor-data entity on a connector. See [Data collection](/products/integrations/capabilities/data-collection). ### Point kind Points The data type a point represents—number, true/false, string, or similar. See [Points](/products/kode-os/points/points). ### Point Time Series Building BI In Building BI, the flattened sensor-reading model—one row per point per timestamp—carrying building, area, device, and point context on each row. ### Point trends Cloud BMS An interface in device details that organizes point data with trend visualizations. See [Trends](/products/kode-os/trends). ### Polling Integrations Scheduled pull collection. KODE OS connects to the external system at a configured interval and requests the latest data for each enabled entity. Polling intervals have default, minimum, and maximum values per integration. Contrast with real-time push methods such as webhooks and MQTT. See [Data collection](/products/integrations/capabilities/data-collection). ### Policies FDD FDD notification preferences including methods, message content, recipients, and escalation. See [Notification policies](/products/fdd/notification-policies). ### Portfolio level AssetOpsBuilding BI A product scope across every building in the portfolio. In Building BI, use it for cross-building analytics. Deployment Manager appears only at this level. See [Building BI overview](/products/building-bi/overview#portfolio-and-building-scope). In AssetOps, portfolio-level work covers shared resources, Priority and SLA, settings, and cross-building monitoring. See [Usage and workflow](/products/assetops/quickstart/usage-workflow). ### PostgreSQL Building BI The Building BI database backend used for wide, high-dimension non-sensor data. It supports virtual tables and a different SQL dialect than ClickHouse or BigQuery. ### Predefined view Building BI In Building BI Deployment Manager, the governed, centrally synced copy of a deployed dashboard. It updates when the source publishes. See [Deployment manager](/products/building-bi/deployment-manager#predefined-and-custom-views). ### Preventive maintenance AssetOps In AssetOps, proactive routine maintenance to prevent failures and keep assets healthy. It is delivered through schedules as scheduled work orders. See [Work orders](/products/assetops/quickstart/work-orders). ### Priority AssetOps In AssetOps, a portfolio-configured urgency level for work orders, with optional default, color, and linked SLA targets. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Projects FTT An FTT initiative that runs functional testing across multiple floors on a schedule. See [Projects](/products/ftt/projects). ### Publish Building BI In Building BI, the action that pushes the current draft live so viewers and collaborators see the published version. For collections, publish also controls which roles can see the dashboards. See [Dashboards](/products/building-bi/dashboards) and [Collections](/products/building-bi/collections#publish-a-collection). ### Push and swap charts Building BI In Building BI, a Dashboard Options setting that lets you move widgets by pushing or swapping adjacent widgets instead of overlapping them. ## Q ### QoS Integrations QoS stands for Quality of Service in MQTT. It sets the delivery guarantee for a published message: 0 (at most once), 1 (at least once), or 2 (exactly once). Higher QoS improves reliability and can increase broker load. See [MQTT](#mqtt) and [MQTT integrations](/products/integrations/capabilities/mqtt). ## R ### Raw table Building BI In Building BI, a table widget that shows source data largely unchanged—one row per record—for audit, troubleshooting, or export. ### Real-Time Building BI In Building BI, the physical Point Time Series table that stores every reading as its own row. It is the full history and source of truth for trends. ### Reference line Building BI In Building BI, a static horizontal or vertical line on a chart used to mark a setpoint or threshold. ### References DevicesCloud BMS Relationships between devices—such as feeds or associations—managed in Cloud BMS. See [Device referencing](/products/kode-os/devices/device-referencing). ### Refresh cache Devices Updates stored connectivity data so devices are reflected accurately as online or offline. See [Devices](/products/kode-os/devices/devices). ### Renewable energy certificate (REC) EnerG In EnerG, a volume-based renewable attribute that can be allocated, retired, and shown in emissions overview and offset charts. See [Emissions contracts](/products/energ/analytics/portfolio-emissions-contracts). ### Report Builder EnerG In EnerG, a portfolio tool to create, schedule, and export configurable reports for energy, water, waste, cost, and emissions. See [Reporting](/products/energ/finance/reporting). ### Response SLA AssetOps In AssetOps, the time target on a priority level to acknowledge and assign a work order. See [Priority and SLA](/products/assetops/portfolio/priority-sla). ### Routines FDD Configurable FDD algorithms that report specific events while respecting set parameters. See [Routines](/products/fdd/routines). ### Routing and dispatch AssetOps In AssetOps, the building-level mapping of portfolio categories and issue types to a default team and assignee when creating corrective work orders. See [Routing and dispatch](/products/assetops/resources/routing-dispatch). ## S ### Scenario EnerG In EnerG Capital Planning, a funded package of conservation measures with priority and implementation dates, analyzed for savings on the Capital Planning Roadmap. See [Capital planning](/products/energ/sustainability/capital-planning). ### Schedule AssetOpsIntegrationsCloud BMS A user-set timeline that defines device behavior over a period. See [Schedules](/products/kode-os/schedules). In AssetOps, a schedule is a building-level configuration that generates recurring or on-demand work orders for preventive maintenance or inspections. See [Schedules](/products/assetops/schedules/schedules-overview). In Integrations, schedules on a connector can be weekly (recurring by day of week) or calendar (exceptions and one-time events). KODE OS can discover, create, update, delete, and sync schedules when the vendor API supports it. See [Schedules](/products/integrations/capabilities/schedules). ### Schedule sync Integrations An Integrations entity that keeps schedule state aligned between KODE OS and the external system. Schedule Sync is separate from discovering or editing schedule definitions. See [Schedules](/products/integrations/capabilities/schedules) and [Data collection](/products/integrations/capabilities/data-collection). ### Schedule type AssetOps In AssetOps, how a schedule runs: Just once, Recurrent, or On demand. See [Schedules](/products/assetops/schedules/schedules-overview). ### Scheduled report Building BI In Building BI, a recurring PDF export of dashboard pages emailed to recipients on a defined schedule. ### Scheduled work order AssetOps In AssetOps, a work order generated from a schedule for preventive maintenance or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Scope 1 emissions EnerG In EnerG, direct greenhouse gas emissions such as on-site natural gas and tracked fleet or fugitive sources. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Scope 2 emissions EnerG In EnerG, indirect emissions from purchased energy such as electricity and district steam, including market-based and location-based totals. See [Emissions overview](/products/energ/analytics/portfolio-emissions-overview). ### Sequence FTT An FTT process that tests whether a device maintains setpoints under different conditions. See [FTT overview](/products/ftt/overview). ### Series colors Building BI In Building BI, a color application method that assigns a specific color to a specific string or Boolean series value so meaning stays consistent across dashboards. ### Service type EnerG In EnerG, what flows through a meter—electric, natural gas, steam, water, and related commodities—grouped as energy, water, or waste for portfolio totals. See [Key concepts](/products/energ/get-started/key-concepts). ### Session timeout Launchpad How long a signed-in session stays active before inactivity logs the user out. See [Security settings](/products/launchpad/get-started/security-settings). ### Shared link Building BI A URL that lets people view and interact with a Building BI dashboard or widget without a normal app session. You can set expiration, refresh rate, and allowed IP addresses. Also called a shareable link. ### Sign-in methods Launchpad Identity and access options for how users authenticate, managed in Launchpad. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). ### Single sign-on (SSO) Launchpad Lets users access KODE with corporate identity-provider credentials such as Azure AD or other SSO providers. See [Configure single sign-on](/products/launchpad/get-started/configure-single-sign-on-sso). ### Slicer Building BI In Building BI, an on-canvas widget bound to a single column that applies an interactive filter to widgets within its scope. ### Smart Generation EnerG In EnerG Budget Planning, the method that builds projections from history, as opposed to Reference Year or Manual Entry. See [Budget planning](/products/energ/finance/budget-planning). ### Snapshot Integrations In Integrations, a collection mode that captures the full current value of points at each collection cycle. Use it for occupancy counts, current temperatures, and door status. See [Collection mode](#collection-mode) and [Data collection](/products/integrations/capabilities/data-collection). ### Status transition AssetOps In AssetOps, a portfolio rule that controls which roles may move work orders between statuses. See [Status transitions](/products/assetops/quickstart/settings-status-transitions). ### Structured Data Pull Building BI In Building BI, a Point Time Series polling pattern—usually for API-sourced data—that writes one row per polling interval rather than only on change of value. ### Sync and bulk deploy Building BI In Building BI, the permission and Deployment Manager capability that lets a role deploy dashboards across sites, edit or delete deployments, and manage predefined synced views. See [Deployment manager](/products/building-bi/deployment-manager). ### Systems Smart Building A user-defined group of logically connected devices shown in a single view. See [Systems](/products/kode-os/systems). ## T ### Table view Cloud BMS Device history and performance in a structured table, often with CSV export. See [Trends](/products/kode-os/trends). ### Target EnerG In EnerG, a sustainability reduction goal—service type, metric, baseline, and reduction method—tracked at portfolio or building level. See [Targets](/products/energ/analytics/portfolio-targets). ### Target slot Cloud BMS A BACnet priority designation (typically 1–16) used when scheduling maps devices or points. See [Schedules](/products/kode-os/schedules). ### Task group AssetOps In AssetOps, a portfolio bundle of task templates that share a work type and asset types so a schedule can apply a full checklist at once. See [Task templates](/products/assetops/resources/task-templates). ### Task template AssetOps In AssetOps, a reusable task definition for preventive or inspection work, including instructions, estimated time, and asset types. The template is copied onto generated work orders. See [Task templates](/products/assetops/resources/task-templates). ### Team AssetOps In AssetOps, a building-level group of users who complete work orders assigned to that team. See [Teams](/products/assetops/resources/teams). ### Templates Building BIDevices In devices, a predefined structure for a device's essential functions and components. See [Device templates](/products/kode-os/devices/device-templates). In Building BI, a reusable collection, dashboard, page, or chart configuration. Applying a template creates an independent copy, unlike deployment sync. See [Templates](/products/building-bi/templates) and [Templating vs deployment](/products/building-bi/concepts/templating-vs-deployment). ### Test connections Cloud BMS A quick check of data source, device, or point connectivity status. See [Data sources](/products/kode-os/data-sources). ### Timezone Building BI In Building BI, the timezone used to resolve a dashboard's date and time filters. Portfolio dashboards often default to UTC. Building-level dashboards often inherit the building timezone. See [Dashboards](/products/building-bi/dashboards). ### Top N filter Building BI In Building BI, a filter that keeps only the highest or lowest N items by a chosen metric and hides the rest. See [Filter options](/products/building-bi/reference/filter-options). ### Trusted organizations Launchpad External organizations with a trust relationship that can receive specific permissions, such as MFA settings. See [Security settings](/products/launchpad/get-started/security-settings). ### Two-factor authentication (2FA) Launchpad A preference that requires a second factor at sign-in. See [Security settings](/products/launchpad/get-started/security-settings) and [MFA](#mfa). ## U ### Unacknowledged FDD Events or incidents that assignees have not yet acknowledged. See [Events](/products/fdd/events). ### Units Devices Individual inputs or devices—such as sensors or meters—that gather and transmit operational data. See [Devices](/products/kode-os/devices/devices) and [Manual meters](/products/kode-os/devices/manual-meters). ### Users Launchpad A person with an account in KODE. See [Accounts and users](/products/launchpad/get-started/accounts-and-users). ### Utility bill meter EnerG In EnerG, a meter that settles on monthly billing periods from utility statements. It is the primary feed for portfolio Home, dashboards, targets, budgets, and Alert Center. See [Key concepts](/products/energ/get-started/key-concepts). ### Utility rate EnerG In EnerG Capital Planning, the blended cost per unit used for cost translation and savings narratives. See [Capital planning](/products/energ/sustainability/capital-planning). ## V ### Vendor AssetOps In AssetOps, a portfolio-level external service provider shared across buildings and assignable on work orders. See [Vendors](/products/assetops/resources/vendors). ### Version history Building BI In Building BI, the log of saved dashboard versions—date, author, and optional name—that you can preview, restore as draft, or publish. See [Dashboards](/products/building-bi/dashboards). ### Virtual data source Building BI In Building BI, a saved SQL view over physical tables that computes rows on demand when queried. See [Physical vs virtual data sources](/products/building-bi/concepts/physical-vs-virtual-data-sources). ### Virtual device Devices A user-created device that combines points from one or more devices into a single view. See [Virtual devices](/products/kode-os/devices/virtual-devices). ## W ### Water Use Intensity (WUI) EnerG In EnerG, water consumption normalized by floor area or another relevant denominator. See [Benchmarking](/products/energ/analytics/benchmarking). ### Weather normalization EnerG In EnerG, a baseline configuration option that trains regression models to adjust usage for heating and cooling conditions. See [Baseline configurations](/products/energ/analytics/baseline-portfolio-configurations). ### Webhook Integrations A push method where the external system sends an HTTP request to a KODE OS URL when an event occurs. KODE OS does not poll for that event. After you create the connector, copy the webhook URL from the connector detail page into the vendor system. See [Data collection](/products/integrations/capabilities/data-collection) and [Managing connectors](/products/integrations/get-started/managing-connectors). ### Weekly schedules IntegrationsCloud BMS Recurring weekly operating times for connected devices. See [Schedules](/products/kode-os/schedules). In Integrations, weekly schedules define day-of-week routines such as business hours and off-hours setpoints. Contrast with calendar schedules for holidays and one-time exceptions. See [Schedules](/products/integrations/capabilities/schedules). ### Widget view Cloud BMS A system view that shows devices and their points as widgets. See [Systems](/products/kode-os/systems). ### Widgets Building BI Customizable components on a Building BI dashboard canvas—charts, slicers, cards, tables, graphics, navigation controls, and similar items. See [Widget customization](/products/building-bi/widget-customization) and [Dashboards](/products/building-bi/dashboards). ### Work order AssetOps In AssetOps, a single trackable unit of maintenance work such as a repair, upkeep, or inspection. See [Work orders](/products/assetops/quickstart/work-orders). ### Work order status AssetOps In AssetOps, the lifecycle state of a work order, including Open, In progress, On hold, For review, Completed, Failed, Cancelled, and Overdue. See [Work orders](/products/assetops/work-orders/work-orders-overview). ### Workflows FTT Preconfigured logical sequences in FTT for designing and deploying test logic for devices or buildings. See [Workflows](/products/ftt/workflows). ### Workspace domain Launchpad The web address members use to access KODE, typically in the form `companyname.kodelabs.com`. See [Workspaces and sign-in](/products/launchpad/get-started/workspaces-and-sign-in). *** ## Smart Building terminology Common abbreviations for building systems, equipment, and points. This list is separate from the A–Z product glossary above. ### Zone Smart Building | Abbreviation | Meaning | | - | - | | `VAV` | Variable Air Volume | | `CAV` | Constant Air Volume | | `FPB` | Fan Powered Box | | `FCU` | Fan Coil Unit | | `UH` | Unit Heater | | `EUH` | Electric Unit Heater | | `CUH` | Cabinet Unit Heater | | `ECUH` | Electric Cabinet Unit Heater | | `HP` | Heat Pump | ### Air conditioning Smart Building | Abbreviation | Meaning | | - | - | | `VRV` | Variable Refrigerant Volume | | `VRF` | Variable Refrigerant Flow | | `CU` | Condensing Unit | | `AC` | Air Conditioning | | `CRAC` | Computer Room Air Conditioning | ### Frontend Smart Building | Abbreviation | Meaning | | - | - | | `HVAC` | Heating Ventilation and Air Conditioning | | `IoT` | Internet of Things | | `IBMP` | Intelligent Building Management Platform | | `UUI` | Unified User Interface | | `BAS` | Building Automation System | | `BMS` | Building Management System | | `BEMS` | Building Energy Management System | ### Drives Smart Building | Abbreviation | Meaning | | - | - | | `VFD` | Variable Frequency Drive | | `VSD` | Variable Speed Drive | ### Major mechanical Smart Building | Abbreviation | Meaning | | - | - | | `RTU` | Rooftop Unit | | `AHU` | Air Handling Unit | | `MAU` | Make Up Air Unit | | `DOAS` | Dedicated Outdoor Air System | | `EF` | Exhaust Fan | | `FAMU` | Forced Air Make Up Unit | ### Systems Smart Building | Abbreviation | Meaning | | - | - | | `CT` | Cooling Tower | | `Blr` / `B` | Boiler | | `HX` | Heat Exchanger | | `CH` | Chiller | ### Point Smart Building | Abbreviation | Meaning | | - | - | | `ZNT` / `SPT` | Zone Temperature | | `SP` | Set Point | | `SS` | Start/Stop Command | | `Cmd` | Command | | `Sts` / `S` | Status | | `DAT` | Discharge Air Temperature | | `DAH` | Discharge Air Humidity | | `RAT` | Return Air Temperature | | `RAH` | Return Air Humidity | | `MAT` | Mixed Air Temperature | | `OAT` | Outside Air Temperature | | `OAH` | Outside Air Humidity | | `DX` | Direct Expansion | | `Vlv` | Valve | | `Dmpr` | Damper | | `DAF` | Discharge Air Flow | | `OAF` | Outdoor Air Flow | | `RAF` | Return Air Flow | # Optimized start/stop on mobile Source: https://docs.kodelabs.com/products/mobile-app/operations/oss Set OSS operation modes, scope equipment, and review active status from the OSS module on the KODE OS mobile app. Optimized start/stop (OSS) starts HVAC equipment just in time so zones hit their setpoint by occupancy, instead of running on a fixed schedule. On mobile, choose how aggressively the system pre-heats or pre-cools zones and control which equipment participates. This page follows [OSS](/products/kode-os/oss) on the web. ## Open OSS Select `OSS` from the building app launcher (label varies by site). ![OSS screen with Balanced selected, FCU and VAV counts, and OSS is active status](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-oss-optimizations.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=4fcdc3d7fd4c60957fb44440b2173a20) The footer shows whether OSS is running for the current site (for example, `OSS is active`). Use the notification bell when your site sends OSS alerts. ## Operation mode Three radio options set the optimization strategy for scoped equipment: | Mode | Goal | | - | - | | `Comfort` | All zones on setpoint by occupancy start; comfort first | | `Balanced` | Third quartile of zones on setpoint; balance comfort and energy | | `Energy Saving` | Median of zones on setpoint; energy first | Tap the info icon next to the title to open definitions, then `Close` to return. ![Modal describing Comfort, Balanced, and Energy Savings operation modes](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-oss-operation-mode-info.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=48747c73c169473cc7ff97e34225ff86) Operation mode help sheet Select a mode to apply it for the building. Your site may require OSS to be activated on web before mobile shows `OSS is active`. ## Equipment scope Below `Operation Mode`, `OSS` lists equipment groups included in the run: | Row | Meaning | | - | - | | `FCUs 40/40` | Forty fan coil units in scope on Floor 2 | | `VAVs 14/14` | Fourteen variable air volume boxes on Floor 2 | | `AHU Floor 2 2/2` | Two air handlers on Floor 2 | | `AHU Floor 1 2/2` | Two air handlers on Floor 1 | The fraction is included devices / total devices in that category. Tap a row to add or remove individual units when your role allows configuration on device. ## Add or remove devices Opening a category (for example, `FCUs`) shows a checklist of units. Clear or select rows, then tap `Save` to update scope. ![FCUs Add Remove devices modal with FCU\_101 through FCU\_106 checked and Save button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-oss-add-remove-devices.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=b75cbf90714bbf523ecde549aa9f2379) FCUs add/remove devices | Control | Action | | - | - | | Checkbox | Include or exclude a unit from OSS for this category | | `40/40` (header) | Selected count versus total in the group | | `Save` | Apply changes and return to `OSS` | Excluding a device removes it from the next optimization cycle for that adapter—the configuration that customizes OSS for a specific HVAC system. Use web [OSS](/products/kode-os/oss) for adapter setup, learning mode, bypass, and dashboard history when those controls are not on mobile. ## Compare to web | Capability | Web | Mobile | | - | - | - | | Operation mode (Comfort / Balanced / Energy Saving) | Yes | Yes | | Per-category device scope | Yes | Yes (add/remove modal) | | Activate OSS / learning / bypass | Full | Status shown; advanced controls on web | | Performance dashboard and trends | Full | Not shown on mobile | ## Next steps > [card] [Schedules on mobile](/products/mobile-app/operations/schedules) > > Edit weekly days, special events, and holidays. > [card] [Systems on mobile](/products/mobile-app/destinations/systems) > > Switch dashboard, graphic, and widget views. > [card] [OSS on web](/products/kode-os/oss) > > Adapter setup, learning, and dashboards. # Schedules on mobile Source: https://docs.kodelabs.com/products/mobile-app/operations/schedules View and edit weekly schedules, special events, and holiday calendars from the KODE OS mobile app. A **schedule** sets when equipment should be occupied or unoccupied—for example, Monday through Friday business hours. On mobile you can view schedules and edit weekly days, special events, and holidays when the connector allows it. Schedules match [Schedules](/products/kode-os/schedules) on the web. Many building controllers use **BACnet**, a common protocol for building automation. Schedule capabilities depend on that connection. > [!NOTE] > > Which actions appear depends on the schedule data source. Tap the info (`i`) icon on a schedule to see `Allowed Actions` for that connector. ## Open Schedules Open `Schedules` from the building app launcher or from `Schedules` on a [device menu](/products/mobile-app/building/devices#device-menu). ![Schedules list with Weekly Schedules tab and Test Training row](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedules-list.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=49b3c476a17f5c8c4e4300928809b764) Choose the list type at the top: | Tab | What it contains | | - | - | | `Weekly Schedules` | Recurring weekday patterns tied to equipment points | | `Calendar Schedules` | Holiday and calendar-style exceptions | Pink banners may appear when the platform detects data issues—for example, devices deleted from the data source, or schedules without point references. Resolve those on the web or connector before you rely on mobile edits. Tap search, type part of a name, and tap a result. `Cancel` clears search. ## Edit a weekly schedule Tap a `Weekly Schedules` row (for example, `Test Training`) to open the editor. ### Header actions | Control | Purpose | | - | - | | `Back` | Return to the list | | `Sync` | Refresh from the data source; shows `Last Synced` | | Info (`i`) | Show `Allowed Actions` for this connector | ![Test Training weekly schedule editor showing Back, Sync, and Info header actions with Monday through Friday timeline bars](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedule-weekly-editor.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=a8d67bff8123409530e31ab686123814) Weekly schedule editor with header actions and day timeline Typical supported actions include list, create, update, and delete for schedules, schedule days, special events, and effective periods. > [tab] Weekly > > The `Weekly` tab shows occupied hours per weekday. > > ![Weekly tab with Monday through Friday 10 AM to 5 PM timeline bars](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedule-weekly.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=ac0dbe5d42540a6ec5d8699ed02d0d1f) > > | Element | Description | > | - | - | > | `Calendar View` toggle | Switch list versus timeline grid | > | Day row | Day name, time range, default value (`true` / `false`) | > | Timeline bar | Green segment for occupied hours on a 24-hour track | > | Overflow (`⋯`) | Edit or remove that day’s pattern | > | Add (`+`) | Add a new weekly day event | > > #### Add or edit a weekly day > > Tap `+` or the day overflow menu, then configure `Add New Event`: > > ![Add New Event modal with day, times, default value, and Synced badge](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedule-add-event.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=96b7ce0f1f2397772abeeb94f41887db) > > | Field | Description | > | - | - | > | `Day of Week` | Weekday to apply | > | `Start Time` / `End Time` | Occupied window | > | `All Day` | Span the full day when enabled | > | `Default Value` | Output during the window (`true` / `false`) | > | `Null` | Write null instead of true/false when supported | > | `Synced` | Green badge when the change is saved to the source | > | `Save` | Commit the event | > > Turn `Calendar View` on and pick a day letter to see hourly rows with a green block for the active window. > [tab] Special Events > > `Special Events` lists one-off or recurring exceptions (custom or reference types). > > ![Special Events tab with Custom and Reference Christmas events](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedule-special-events.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=42dea3c91c224caae632236e66e3d9d7) > > | Label | Meaning | > | - | - | > | `Custom` | Event defined only in this schedule | > | `Reference` | Points to another schedule slot (path shown when expanded) | > | Time range | Active window for the exception | > | Default value | `false` or `true` during the event | > | `Show Details` | Expand reference path or extra fields | > | Overflow (`⋯`) | Edit or delete | > > Use the `+` button to add a special event when `Allowed Actions` includes create. > [tab] Details > > `Details` shows read-only metadata and BACnet facets. > > ![Details tab with schedule name, data source, kind, and location path](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-schedule-details.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=da24e78c85b8aa03df5836f3e73ad9b6) > > | Group | Examples | > | - | - | > | Schedule details | Name, display name, data source, kind, point type, area, current value, tags, `Location` path | > | Properties | Effective period, default output, facets (for example, `falseText`) | > > Use this tab to confirm you opened the correct schedule before editing weekly or special events. ## Manage holiday calendars Open `Calendar Schedules`, then open `Holiday Schedule` (or search for `holiday`). ![Holiday Schedule list with Memorial Day, Independence Day expanded date pattern, Thanksgiving, and New Event button](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-holiday-schedule.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=11eb5f999c75fad3ac4af49591032481) | Control | Purpose | | - | - | | Refresh | Sync holidays from the source | | Info (`i`) | Help for holiday rules | | Overflow (`⋯`) | Edit or delete | | `Show Details` | Expand date pattern grid | | `New Event` | Add a holiday | Tap overflow on a holiday row to reveal `Delete` and `Edit`. ### Add a holiday Tap `New Event`, then set: | Field | Description | | - | - | | `Display Name` | Label in lists | | `Type` | `Date` or `Week And Day` | | Day of week / week of month / month | Pattern when type is `Week And Day` | | `Save` | Write to the data source | | Type | Use for | | - | - | | `Date` | Fixed calendar day (for example, day `4`, month `Jul`, year `Any`) | | `Week And Day` | Floating holidays (for example, the nth weekday of a month) | ![Independence Day expanded with Week Day, Day, Month, and Year fields](https://mintcdn.com/kodelabs/IXjGUtCN1G_ZdIHf/images/mobile-app/kode-os-mobile-holiday-schedule-details.png?fit=max\&auto=format\&n=IXjGUtCN1G_ZdIHf\&q=85\&s=ca84a2982d8b1877b71eb7cafb5b71bf) Fixed date example: July 4 ## Web vs mobile | Task | Platform | | - | - | | Create schedule definitions on new points | Web | | Bulk BACnet downloads | Web | | View, edit weekly days, special events, holidays | Mobile (when allowed) | | Effective period advanced edits | Web preferred | ## Next steps > [card] [Optimized start/stop](/products/mobile-app/operations/oss) > > Set operation mode and equipment scope. > [card] [Points on mobile](/products/mobile-app/building/points) > > Browse status, filters, and point writes. > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. # Work orders on mobile Source: https://docs.kodelabs.com/products/mobile-app/operations/work-orders Triage, update, and create AssetOps work orders from the KODE OS mobile app. Pick up a maintenance task, update its status, and log what you did—all from the field. `Work Orders` on mobile reads and writes the same building-level [AssetOps](/products/kode-os/assetops/work-orders) records as KODE OS web. AssetOps is the KODE maintenance product that tracks work orders, schedules, and assets across a portfolio. Open the app to review open tasks, assign yourself, change status, and link work to assets such as `VAV_3`. > [!NOTE] > > `Work Orders` appears in the building launcher when AssetOps is enabled for your organization and site. It is separate from [FDD work orders](/products/fdd/work-orders), which create tickets from fault events. ## Open Work Orders Select `Work Orders` from the building app launcher. Use the header icons to refresh, filter, or create a follow-up. ![Work Orders list with Open status, priority, SLA Breached, and VAV\_3 asset links](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-orders-list.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=22f1d3dc2d1ff9bb2536faa626868800) Each card shows: | Element | Description | | - | - | | Title | Work order name | | Priority | For example, `Medium` | | SLA Status | For example, `Breached` | | Identifier | Work order ID such as `WO-05729` | | Category / Issue type | Classification metadata | | Dates / Assignee | Start–due range and assignee | | Asset | Linked equipment (tap to open the device) | | Status | `Open`, `In Progress`, or other state | ### Filter and focus Tap the status dropdown to limit the list: ![Work Orders status menu with Open selected](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-orders-status-menu.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=1a6b277b10fc0e55e6286f99e4536920) All, Open, In Progress, Completed, On Hold Tap the filter icon for advanced criteria: ![Work Order Filters for work type, asset, area, category, and issue type](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-orders-filters.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=656a7bf1598cf4f8e14699d5e4a4b3e5) Turn on `Focus Mode` on the list screen to narrow the set to your assigned or high-priority work when your site configures it. ## Work order detail Tap a card to open the detail screen. > [tab] Details > > ![Work order Test May Open status with asset VAV\_3 and Assign Me button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-detail-open.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=48544fa9367a730d5e8012432cc592c5) > > `General Information` includes `Title`, `Identifier`, `Building`, `Priority`, `SLA Status`, `Asset`, `Work Type`, `Category`, and `Issue Type`. Tap `Assign Me` to take ownership when you are unassigned. > > #### Update status > > Change status from the dropdown at the top of `Details`: > > ![Work order status menu with On Hold, Cancelled, For Review, and In Progress](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-status-change.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=2095add095cef6ed92522d39705477b5) > > When you move to `In Progress`, add optional notes: > > ![In Progress sheet with Notes field and Save button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-in-progress-notes.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=1ee47bc782727f9f2fa83bf84aa5269d) > > Notes when starting work > > ![Work order In Progress with success toast after status change](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-detail-in-progress.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=a955e97072d5cbb5c3fea6833c443c4d) > > #### More actions > > Open the more menu in the header for administrative actions: > > ![Work order menu with Status History, Edit, Delete, and Share](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-more-menu.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=27414427d68c37af94bd7064b457b5f2) > > | Action | Use for | > | - | - | > | `Status History` | Audit trail of status changes | > | `Edit` | Update title, dates, asset, category, and issue type | > | `Delete` | Remove the work order when permitted | > | `Share` | Send a link or summary | > > ![Status History timeline from Open to In Progress with user and timestamp](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-status-history.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=991e928690a1883b7884685a7d7fdcaa) > > Status timeline > > #### Edit work order > > ![Edit Work Order form with title, dates, asset VAV\_3, category, and issue type](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-edit.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=fa1aa261db8616611178cb4404b639bc) > [tab] Attachments > > Add photos or files on the `Attachments` tab. > > ![Work order Attachments tab with Add Attachment button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-attachments.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=f977cb10f2a893b933c3e8de6ad44fe2) > > Open the chat icon or comments flow for team discussion: > > ![Work order Comments with rich text toolbar and Enter comment field](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-comments.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=fd40968647df4afc73430de93985cb41) > [tab] Follow-ups > > The `Follow-ups` tab lists child tasks. Tap `+ Create Work Order` to add a follow-up on the same record. > > ![Follow-ups tab with Create Work Order button](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-follow-ups.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=c22c27223757658f6b33b42c7b9fe45d) > > ![Create Follow-up form with work type, asset, area, and dates](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-create-follow-up.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=674c3e55806d1e92e05b1dcf014800ea) > > Internal follow-up > > To route work to an external CMMS, tap `Create External` and complete the integration form: > > ![Create External Follow-up with Name, Data Source, Entity, and Action fields](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-work-order-create-external.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=162da95e8a0f5470d0e3e84e0d248a7a) ## Create work from other modules You can start work orders from FDD events, faults, and devices when your role allows: * [Events on mobile](/products/mobile-app/events/work-with-events#work-orders-and-comments) — `Work Orders` on the event menu * [Manage FDD faults](/products/mobile-app/diagnostics/manage-fdd-faults) — fault detail menu * [Devices on mobile](/products/mobile-app/building/devices) — device more menu Those flows use the same AssetOps work order record type as the `Work Orders` app. ## Compare to web | Web capability | Mobile | | - | - | | List, status filter, Focus Mode | Yes | | Work order detail and status change | Yes | | Assign me, edit, status history | Yes | | Attachments and comments | Yes | | Follow-ups and external create | Yes | | Bulk edit and export | Use web | | Portfolio dashboards and schedules | Use [AssetOps](/products/assetops/quickstart/overview) web | ## Next steps > [card] [AssetOps work orders](/products/kode-os/assetops/work-orders) > > Full work order admin on the web. > [card] [Understanding work orders](/products/assetops/quickstart/work-orders) > > Learn AssetOps work order concepts. > [card] [Devices on mobile](/products/mobile-app/building/devices) > > Open equipment, trends, and device actions. # KODE OS mobile app overview Source: https://docs.kodelabs.com/products/mobile-app/overview Use KODE OS on iOS and Android to monitor buildings, triage events, command equipment, and run diagnostics from the field. The KODE OS mobile app brings the same building tools as the web platform to iOS and Android. Most work happens in **module views**—lists, charts, dashboards, and floor plans built for phones. You can also do limited configuration on mobile, such as schedule edits, point overrides, holiday rules, bookmarks, and optimized start/stop modes. ## Download the app * [Apple App Store](https://apps.apple.com/om/app/kode-os/id1479690443) * [Google Play](https://play.google.com/store/apps/details?id=com.kodelabs.klp\&hl=en_US\&gl=US) > [!NOTE] > > On first launch, enter your workspace domain (for example, `yourcompany.kodelabs.com`). Some organizations use `kodemobile` on the first screen—confirm the correct value with your administrator. ## Typical workflow **1. Sign in and pick an organization** Connect to your workspace, then open the organization you need. See [Sign in and workspace](/products/mobile-app/get-started/sign-in-and-workspace). **2. Choose portfolio or a site** Use the portfolio map for cross-site context, or `Switch Site` to work inside one building. See [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites). **3. Open a module from the app launcher** Each KODE OS app (`Events`, `Systems`, `Building BI`, and others) opens in a focused mobile layout. See [Navigate the app](/products/mobile-app/get-started/navigation). **4. Configure when needed** Use mobile settings for appearance, bookmarks for shortcuts, and module-specific actions (schedules, overrides, holidays) when your role allows. ## What you can do on mobile vs web Modules such as device templates, routine authoring, and Building BI deployment remain web-first. Mobile is built for monitoring, triage, commanding, and limited in-field configuration. > [accordion] Web module to mobile guide map > > | KODE OS web module | Mobile app guide | Mobile focus | > | - | - | - | > | [Sites](/products/kode-os/sites-and-map) | [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites) | Map, site cards, switch site | > | [Systems](/products/kode-os/systems) | [Systems](/products/mobile-app/destinations/systems) | Widget, graphic, and dashboard views | > | [Areas](/products/kode-os/areas) / [Floor plans](/products/kode-os/graphics/floor-plans) | [Areas and floor plans](/products/mobile-app/building/areas) | Area list, layered maps, occupancy, and temperature | > | [Devices](/products/kode-os/devices/devices) | [Devices](/products/mobile-app/building/devices) | Point values, trends, bookmarks, device menu | > | [Manual meters](/products/kode-os/devices/manual-meters) | [Manual meters](/products/mobile-app/building/manual-meters) | Add meters, log readings, reading history | > | [Trends](/products/kode-os/trends) | [Trends](/products/mobile-app/analytics/trends) | Charts, filters, time range | > | [Building BI](/products/building-bi/overview) | [Building BI](/products/mobile-app/destinations/building-bi) | Published collections and dashboards | > | [Events](/products/fdd/events) | [Events](/products/mobile-app/events/work-with-events) | List, detail, acknowledge | > | [FDD dashboards](/products/fdd/dashboards) | [Event dashboards](/products/mobile-app/events/customize-event-dashboard) | Historical analytics cards | > | [FDD faults](/products/fdd/faults) | [FDD on mobile](/products/mobile-app/diagnostics/fdd-overview) | Events, incidents, fault detail | > | [Points](/products/kode-os/points/points) | [Points](/products/mobile-app/building/points) | Status, filters, writable points, overrides | > | [Commanding](/products/kode-os/points/commanding-points) | [Points](/products/mobile-app/building/points#writable-points) | Bulk and single-point writes | > | [Schedules](/products/kode-os/schedules) | [Schedules](/products/mobile-app/operations/schedules) | Weekly, special events, holidays | > | [AssetOps work orders](/products/kode-os/assetops/work-orders) | [Work orders](/products/mobile-app/operations/work-orders) | List, status, assign, follow-ups, asset link | > | [OSS](/products/kode-os/oss) | [Optimized start/stop](/products/mobile-app/operations/oss) | Operation mode and equipment scope | > | [FTT](/products/ftt/overview) | [Functional testing](/products/mobile-app/diagnostics/functional-testing) | KPIs, sequence scores, trends | > | [Data sources](/products/kode-os/data-sources) | [Data sources](/products/mobile-app/building/data-sources) | Connection list and cache actions | ## Get started > [card] [Portfolio and sites](/products/mobile-app/portfolio/portfolio-and-sites) > > Map view, site health, and site switching. > [card] [Events on mobile](/products/mobile-app/events/work-with-events) > > Active and historical events with detail and triage. > [card] [Points](/products/mobile-app/building/points) > > Status badges, filters, writable points, and overrides. > [card] [Customize experience](/products/mobile-app/get-started/customize-experience) > > Profile, theme, bookmarks, and organization switching. ## Support Contact [support@kodelabs.com](mailto:support@kodelabs.com) for access or app issues. # Portfolio and sites on mobile Source: https://docs.kodelabs.com/products/mobile-app/portfolio/portfolio-and-sites Use the portfolio map, site cards, module picker, sort, search, and notifications on the KODE OS mobile app. Check the health of every site you manage before you pick which one to visit. The portfolio map shows every building you can access as a pin. Spot down devices and open events at a glance, then drill into a site for building operations. This is the mobile counterpart to [Sites](/products/kode-os/sites-and-map) on the web. ## Open the portfolio map Swipe up the bottom sheet and confirm `Portfolio` / `All Sites Overview` is selected, or tap `All Sites` on the right. The map shows pins for every site you can access. ![World map with site pins, KodeLabs HQ site card, weather widget, and Portfolio bottom sheet](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-map.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=8b1421993abf1197515b7c920e5aecbd) ## Map toolbar | Control | Purpose | | - | - | | Profile (top left) | Open [settings and profile](/products/mobile-app/get-started/customize-experience) | | Refresh / search | Open site search on the map (see below) | | Sort | Change how site cards are ordered | | Expand | Full-screen map | | `View All` | Open the full site list when cards are scrollable | ## Site cards and pins Swipe the horizontal site cards above the map. Each card includes: * Site name and address * Points down — devices offline or in fault (yellow badge) * Active events — open FDD or operational events (bell badge) * Location pin — centers the map on that site ![Map focused on a region with KodeLabs HQ card showing 127 Down and 0 Active badges](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-map-site-card.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=6b2b03bbac36415f01c68298c83c1f8f) Regional map with site card and weather Tap a blue pin for a normal site. A red pin indicates a site that needs attention (for example, critical events or many devices down). The weather widget shows conditions near the map center. It is informational only and does not change site selection. ## Search sites on the map Tap the refresh/search control to focus the search field. Type a site or address, then submit with the keyboard search key. ![Portfolio map search bar with keyboard and site card visible](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-map-search.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=83946b25276ba6239ba2fa12756d4082) Select `Cancel` to exit search and return to the full map. ## Sort site cards Tap the sort icon (two vertical sliders) to open `Sort by`. ![Sort by menu with Active Events, Down Devices, Building Name, and Created At](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-sort.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=578f76fb3154e0e70ac6a4f550350f09) | Option | Orders sites by | | - | - | | `Active Events` | Highest open event count first | | `Down Devices` | Most offline devices first | | `Building Name` | Alphabetical | | `Created At` | Newest or oldest provisioning date (per organization configuration) | Tap `Close` to apply the sort and return to the map. ## Portfolio module picker The bottom sheet lists portfolio-level modules. `Sites` is the map view; other entries open cross-site tools without entering a building first. ![Portfolio sheet listing Sites, Dashboards, Building BI, FDD, FTT, Work Orders, Bookmarks, and Search](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-module-picker.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=b83ca48e14fe93b8b6a5cb6c95a4ecec) Portfolio modules available from the bottom sheet | Module | Typical use on mobile | | - | - | | `Sites` | Map and site cards (this page) | | `Dashboards` | Portfolio dashboards published to mobile | | `BuildingBI` | Cross-site [Building BI](/products/mobile-app/destinations/building-bi) analytics collections | | `FDD` | Portfolio-level fault views when enabled | | `FTT` | Portfolio commissioning summaries | | `Work Orders` | [AssetOps maintenance lists](/products/mobile-app/operations/work-orders) when enabled | | `Bookmarks` | Saved devices and views | | `Search` | Global search entry | A checkmark shows the active module. Select another row to switch modules. ### Reorder modules Tap `Reorder modules` at the bottom of the sheet. Drag handles to change the order, then tap `Done`. ![Reorder Modules screen with drag handles for Sites, Dashboards, Building BI, and other apps](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-reorder-modules.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=35f5331fd8aa47fc26094c2b716cd4e4) Order is per user on the device and does not change which apps your administrator assigned. ## Notifications Tap the blue bell floating button on the map to open `Notifications`. ![Notifications list with event titles, device paths, and Mark all as read](https://mintcdn.com/kodelabs/MYYnSdKhTqQf34f4/images/mobile-app/kode-os-mobile-portfolio-notifications.png?fit=max\&auto=format\&n=MYYnSdKhTqQf34f4\&q=85\&s=beca64b1c117f1f7e733f3860326c8a3) Each row shows event title, site and device path, point detail, and age. Unread items have a blue dot on the right. Use `Mark all as read` to clear unread state. ## Enter a site **1. Select a site** Tap a site card or map pin for the building you need. **2. Open building modules** After the site loads, use the app launcher or portfolio sheet to open Events, Systems, and other building apps. See [Navigate the app](/products/mobile-app/get-started/navigation). **3. Switch site later** From any building screen, open the bottom bar and tap `Switch Site` to return to the map or pick another property. ## Compare to web | Web (Sites) | Mobile (Portfolio) | | - | - | | Table sort columns | `Sort by` sheet on the map | | Click row to enter site | Tap card or pin | | Sidebar apps | `Portfolio` module picker and `Reorder modules` | | Notification center | Map bell button | ## Next steps > [card] [Navigate the app](/products/mobile-app/get-started/navigation) > > Move between portfolio, site, and modules. > [card] [Building BI on mobile](/products/mobile-app/destinations/building-bi) > > Open published collections and dashboards. # What's new in KODE 3.18 Source: https://docs.kodelabs.com/whats-new/2026/v3.18-september-2026 September 2026 (v3.18) updates across KODE OS, AssetOps, FDD, Building BI, FTT, and integrations. ![What's new in 3.18 banner](https://mintcdn.com/kodelabs/B-pwNrO91ylawNjH/images/whats-new/whats-new-v318-banner.jpg?fit=max\&auto=format\&n=B-pwNrO91ylawNjH\&q=85\&s=2a33b4be8a57d66127ea7525bdb5eab5) # September 15th, 2026 ## Highlights [See full release](#full-release-notes) KODE 3.18 adds **Stream Mode** for live FDD (Fault Detection and Diagnostics (FDD) finds building issues from broader analysis, not just simple instantaneous alarms.) event monitoring and adds a **Camera widget** for Building BI (Building BI is the KODE analytics and dashboard module for portfolio and building data visualization.) . We've also shipped **accumulator and differential readings** for Manual Meters in KODE OS (KODE OS is the platform that connects building systems, apps, and data across your portfolio.) , FTT parameter permissions, six new API connectors, and AssetOps filtering and import improvements. ## Stream Mode in FDD FDD (Fault Detection and Diagnostics (FDD) finds building issues from broader analysis, not just simple instantaneous alarms.) **Stream Mode** inserts new events automatically. Open the full-page Event Stream for a command-center display or facility TV. New rows land at the top, highlight for one to two seconds, and show a **Just Now** badge while they are fresh. Filters stay active. Sorting stays locked to Most Recent. ![Entering and exiting Stream Mode on the Events list with live Event Stream table](https://mintcdn.com/kodelabs/w6omSFg97BoO93aE/images/whats-new/whats-new-v317-stream-mode.gif?s=fc00ed559a18feae6cd21a60b4a38f32) Enter Stream Mode to monitor new events, then exit when you need bulk actions. [Learn more about Stream Mode](/products/fdd/events#stream-mode) ## Camera widget in Building BI Add a live camera feed to any dashboard from the Chart List. Search for **Camera**, set **Camera Type** (for example, **iFrame**), paste a **Source URL**, and select **Embed**. Resize and reposition the widget like any other chart. ![Adding a Camera widget from the Chart List and configuring Camera Type and Source URL](https://mintcdn.com/kodelabs/w6omSFg97BoO93aE/images/whats-new/whats-new-v318-camera-widget.gif?s=45f3bf779782d53a640286f8ebdabcc2) Add Camera from the Chart List, then configure Camera Type and Source URL. [Learn more about the Camera widget](/products/building-bi/reference/camera-widget) ## Full release notes User-facing product updates in 3.18. ### Integrations (API) * **Kastle API** — Collect card access and alarm events through Event Connect REST API v3. Historical collection supports a 90-day lookback. See [Kastle](/products/integrations/access-control/kastle). * **Veolia API** — Collect electric meter status, cumulative energy, and demand from EMSYS or HUBGRADE. See [Veolia](/products/integrations/meters/veolia). * **MaintainX API** — Collect assets, current meter readings, and work orders from MaintainX. See [MaintainX](/products/integrations/work-orders/maintainX). * **Johnson Controls Metasys API** — Collect equipment, points, historical trends, alarms, and audits through Metasys REST API v6. Supported environments can also expose point commands. See [Johnson Controls Metasys](/products/integrations/controllers/jciMetasys). * **Framery API** — Monitor smart pod occupancy and connection status. Collect usage sessions and up to 12 months of session history. See [Framery](/products/integrations/occupancy/framery). * **Lambent Spaces API** — Collect Wi-Fi-derived occupancy, utilization, and capacity for building levels and zones. See [Lambent Spaces](/products/integrations/occupancy/lambent). * **TKE Service Record API 3.0** — Service records now include ticket priority and localized service category in KODE OS work orders. See [TKE Elevator](/products/integrations/elevators/tke). ### FDD — Fault Detection and Diagnostics * **Stream Mode** — Automatic event insertion without manual refresh. Blue highlight for one to two seconds. **Just Now** badge under one minute. Sort locked to Most Recent. Filters persist. See [Stream Mode](/products/fdd/events#stream-mode). * **Create individual work orders in bulk** — Select several events and create one work order for each. Review required fields, send ready records together, and retry incomplete items. See [Create work orders per event](/products/fdd/events#create-work-orders-per-event). ### FTT — Functional Testing Tool * **View FTT Parameters for Manual Test** — Separate Write permission that shows or hides editable parameters for manual tests only. Operators can still run preconfigured tests when parameters are hidden. See the [permissions reference](/products/launchpad/client-organizations/apps/permissions-reference) and [Run a test on a single device](/products/ftt/test-results#run-a-test-on-a-single-device). ### KODE OS — Manual meters * **Accumulator and differential readings** — Enter meter displays or pre-calculated consumption for electric, energy, water, gas, and steam meters. Existing meters receive a differential point. Choose **Reading type** when you add a reading on web or mobile. See [Manual meters](/products/kode-os/devices/manual-meters) and [Manual meters on mobile](/products/mobile-app/building/manual-meters). ### Document Management * **CSI divisions** — Classify documents with a required CSI division and optional specification code. Browse the Division tab in Grouped view, filter by division or code, and reclassify existing files with bulk edit. See [CSI divisions](/products/kode-os/documents/overview#csi-divisions). ### AssetOps * **Asset type filters** — Filter work orders and schedules by asset type to focus on equipment such as fan coil units. See [Building work orders](/products/assetops/work-orders/work-orders-overview#custom-filters) and [Building schedules](/products/assetops/schedules/schedules-overview#filters). * **Download import sheets** — Download the existing file from an AssetOps data source to review an import or prepare the next one. See [Asset discovery](/products/assetops/assets/asset-discovery#view-data-sources). ### Building BI — Dashboards * **Camera widget** — Add a live camera feed from the Chart List. Choose **iFrame**, **URI**, or **Device**, then resize and position the widget with your charts. See [Camera widget](/products/building-bi/reference/camera-widget). ## Improvements and bug fixes ### KODE OS * **Device and navigation reliability** — Device Details accepts new Device Class, Tenant, and Zone values. Site switching now keeps building identity and data aligned, and Tenant Details opens space links in a new tab. * **FDD access controls** — The **No active events** and **Go to FDD** badge appears only for buildings with FDD access. * **Device modeling** — Review Entities prioritizes devices with missing fields or ontology errors. Its pagination menu remains accessible. * **Graphics and trends** — Graphics excludes empty pseudo devices, batch-update graphic columns display consistently, and trend date ranges stay within available data. Trend states now use each point's read-map colors. * **Virtual devices** — Deleting virtual or pseudo devices returns their points to their original folders. * **Connector and help status** — Tunnel status updates automatically, and in-product help links now open `docs.kodelabs.com`. ### AssetOps * **Graphics stability** — Graphics tabs no longer freeze during loading. Smart Config lists remain visible, negative values persist, and zooming preserves device and arrow placement. * **Accurate displays** — Area Plans honor point precision, graphics upload guidance reflects supported file types, and empty pseudo devices no longer appear. * **Asset and site administration** — Asset matching returns more likely matches. Climate zones load consistently, search-menu selections apply correctly, and read-only address fields remain protected. ### Building BI * **Chart colors and labels** — Treemap colors, line-chart tooltip colors, mark-area names, and reference-line names update correctly. The custom color picker scrolls through every option. * **Filters and inputs** — Slicer minimum and maximum values update when you change source types. Date filters, multi-trend checkboxes, and table tooltip sizing behave consistently. * **Templates and previews** — Invalid multi-trend templates return useful validation, pivot tables show accurate errors, and empty data sources retain sample-table column headers. * **Dashboard controls** — Favorite-dashboard actions handle empty lists, time-series tooltips remain visible in small widgets, and rapid site switching no longer interrupts dashboard loading. # What's new in KODE 3.19 Source: https://docs.kodelabs.com/whats-new/2026/v3.19-october-2026 October 2026 (v3.19) product updates across Building BI, FDD, integrations, AssetOps, and Document Management. ![What's new in 3.19 banner](https://mintcdn.com/kodelabs/B-pwNrO91ylawNjH/images/whats-new/whats-new-v319-banner.gif?s=5d5fa33511409c125374940afebb8e8b) # October 13, 2026 ## Highlights [See full release](#full-release-notes) KODE 3.19 introduces **parameters** in Building BI (Building BI is the analytics module for dashboards, charts, and portfolio insights.) and **Event Triage Rules** in FDD (Fault Detection and Diagnostics (FDD) finds building issues from broader analysis, not just simple instantaneous alarms.) . We've also shipped a ZenControl lighting connector, a Smart Meter Texas connector, spreadsheet schedule import in AssetOps (AssetOps is the KODE module for assets, schedules, and maintenance work.) , and a faster connector setup flow. ## Parameters in Building BI Name a value once on a data source (A data source is the dataset a Building BI chart reads, including its columns, metrics, and calculations.) . Reference it as `@name` in calculated columns, calculated metrics, and virtual data source SQL. Each dashboard stores its own values. Open `Parameters` beside `Filters` and change a target, rate, or baseline. The widgets that use it recalculate. A viewer's change stays on that screen until refresh. The data source and other dashboards stay as saved. Choose a display name, a type, and a default. You can add an allowed-values list, require the value, block dashboard overrides, or lock it for viewers. Shared dashboards, mobile view, and PDF export show the saved values. ![Adding a Building BI parameter and referencing it in a calculated column](https://mintcdn.com/kodelabs/B-pwNrO91ylawNjH/images/whats-new/whats-new-v319-parameters.gif?s=93f4ba7d03a1f358917c6a38b134c691) Add a parameter, then reference it as `@name` in a calculated column [Learn more about parameters](/products/building-bi/data-sources#parameters) ## Event Triage Rules in FDD **Event Triage Rules** decide what happens to a work order (A work order is a maintenance job in a connected work order system.) after FDD (Fault Detection and Diagnostics (FDD) finds building issues from broader analysis, not just simple instantaneous alarms.) raises an event (An event is a device-reported occurrence that building management reviews or resolves.) . The rules follow the status your CMMS (A CMMS is the external system that tracks maintenance work orders.) sends back, so the work order stays aligned with the alarm. Five rules run on their own: * **Bad closure** reopens a work order the CMMS closed while the alarm is still active. * **Recurrence reopen** brings the original work order back when the same alarm returns. * **Hold and release** holds lower-priority work until a high-priority event fires at the same building. * **Carry forward** keeps the open work order when a new alarm hits the same device. * **Self-resolving cancellation** cancels the work order after the alarm stays quiet. You can also group events yourself. Select two or more active events at one building and send one work order. Open the rules from `Settings`, then `Triage Rules`. A work order connector is required. ![Event Triage Rules settings with enable toggles, labels, and timing parameters](https://mintcdn.com/kodelabs/B-pwNrO91ylawNjH/images/whats-new/whats-new-v319-event-triage.png?fit=max\&auto=format\&n=B-pwNrO91ylawNjH\&q=85\&s=ff518cf24afd86f6308bc128818f9f32) Turn each rule on, set the window, and choose which priorities release held work [Learn more about Event Triage Rules](/products/fdd/settings#event-triage-rules) ## Full release notes User-facing product updates in 3.19. Integration items include the September 29 patch on 3.18. ### Building BI — Dashboards and data sources * **Parameters** — Declare a typed value on a data source and reference it as `@name` in calculated columns, calculated metrics, and virtual data source SQL. Dashboards store their own values. Viewers can run a private what-if that clears on refresh. Shared links, mobile view, and PDF export keep the saved values. See [Parameters](/products/building-bi/data-sources#parameters). ### FDD — Fault Detection and Diagnostics * **Event Triage Rules** — Five rules keep work orders aligned with live alarms: bad closure, recurrence reopen, hold and release, carry forward, and self-resolving cancellation. You can also group two or more active events at one building into one work order. Configure them under `Settings` > `Triage Rules`. A work order connector is required. See [Event triage rules](/products/fdd/settings#event-triage-rules). ### Integrations (API) * **ZenControl** — Lighting connector for ZenControl sites. REST polling plus Live API events for dim level, scene, colour temperature, override, and gateway connection. Writable points cover dim level, scene, colour temperature, and override. See [ZenControl](/products/integrations/lighting/zencontrol). * **Smart Meter Texas** — Read-only REST connector for Texas electric meters. Discover meters by ESIID and meter number. Collect 15-minute consumption and generation interval reads, plus meter status, disconnect, phases, multiplier, and reverse-flow handling. See [Smart Meter Texas](/products/integrations/meters/smartMeterTexas). * **Service Channel (Lowes) work orders** — The Create Work Order action sends the asset tag and FDD event details in `Description`, maps `AssetId` from the linked device, loads `ProblemType` and `AssetType` from Service Channel, and sets `ScheduledDate` from the priority turnaround. See [Service Channel (Lowes)](/products/integrations/work-orders/serviceChannelLowes#available-actions). * **Connector setup** — `Validate Credentials` loads vendor fields in the background and shows progress. Errors name the cause, and you can retry. When a multi-select vendor field has no options, type comma-separated IDs. See [Managing connectors](/products/integrations/get-started/managing-connectors). * **Discovery metadata** — Discovered devices include manufacturer, model, firmware version, OS version, MAC address, and IP address when the connector provides them. See [Discovery](/products/integrations/capabilities/discovery). * **Connector details date column** — Non-sensor data tables show which date column the selected range applies to, such as `Created At (Local)` or `Collected At`. See [Managing connectors](/products/integrations/get-started/managing-connectors). * **AssetOps work orders** — Collected work orders map `category.name` to `category` and `issueType.name` to `subCategory`. See [AssetOps connector](/products/integrations/work-orders/assetOps). * **Lutron Athena** — Collection skips a device Lutron has removed and continues for the rest. The connector stays up. See [Lutron Athena](/products/integrations/lighting/lutronAthena). * **Wattics** — Point history collection skips a device or point that Wattics has removed. The job continues for every remaining device, and the connector stays up. See [Wattics](/products/integrations/meters/wattics). * **Kastle** — Access Log collection redacts credential holder name, email, and phone by default. Each character is replaced with `*`. Alarm collection is not redacted. See [Kastle](/products/integrations/access-control/kastle). * **Service Channel** — `Store ID` and `Subscriber ID` are drop-downs when the store list loads. If the list is empty, both fields are text boxes. See [Service Channel](/products/integrations/work-orders/serviceChannel). ### AssetOps * **Import schedules from a spreadsheet** — Upload a spreadsheet based on the schedule template to create schedules in bulk. KODE OS checks the data and reports success or the rows to fix. See [Import schedules](/products/assetops/schedules/schedules-overview#import-schedules-from-a-spreadsheet). * **Dashboard date range** — The `Created date` range you pick on the AssetOps dashboard stays in place for your session. You can return to the default range at any time. See [Building dashboard](/products/assetops/building/dashboard). ### Document Management * **Section field** — The CSI specification field under a division is labeled `Section` in document details, filters, upload, and bulk edit. See [CSI divisions](/products/kode-os/documents/overview#csi-divisions). ## Improvements and bug fixes ### AssetOps * **Schedules** — The task template picker shows an `Asset Type` column, and `Select All` honors your search and any templates you cleared. Start dates must fall between 1970 and 2099, with inline validation. Calendar event titles fit inside their blocks, and schedule type validation runs when you select `Continue`. * **Assets** — Asset dates display on the correct day in every building time zone. The asset list shows `Active` and `Out of service` assets. Bulk edit offers `Add New` for manufacturer, and the unit field on technical specifications is required. Opening a deleted asset returns you to your last location. * **Dashboards and layout** — The maintenance forecast dashboard shows charts without a paginated table. Checkbox sizes, dashboard fonts, and asset name headers are consistent. Floor plan, system, and device graphics use the updated design. * **Work orders** — On the portfolio work order form, the `Area` dropdown waits for a building selection. ### KODE OS * **Text display** — Clamped text without spaces wraps cleanly across KODE OS, Launchpad, and Client Admin. # What's new in KODE 3.20 Source: https://docs.kodelabs.com/whats-new/2026/v3.20-november-2026 November 2026 (v3.20) product updates across the KODE API, KODE OS, Building BI, EnerG, and related platform areas. ![What's new in 3.20 banner](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/whats-new/whats-new-v320-banner.gif?s=1e1187b37a7511ad9cbe6e2c348b365d) # November 10, 2026 ## Highlights [See full release](#full-release-notes) KODE 3.20 introduces the public KODE API (The KODE API is the programmatic interface to KODE OS for integrations, automation, and building data.) for **bulk automations and executions** across buildings, a **Weather device** in KODE OS (KODE OS is the smart building operating system that connects equipment, analytics, and operations.), and **Check Usage and Replace Usage** for Building BI (Building BI is the analytics module for dashboards, charts, and portfolio insights.) data sources. We've also shipped assisted meter mapping in EnerG (EnerG is the KODE energy and sustainability module for utility data, benchmarking, and reporting.), floor plan sections, and Trends usability updates. ## KODE API for bulk automations Run portfolio work through one versioned HTTPS interface instead of clicking building by building. Authenticate with a service account, then list buildings, devices, and points your account can reach. From there you can ingest device data, write setpoints, sync AssetOps work orders, manage users, and apply ontology templates at scale. For large executions, use the bulk paths: * **Batch writes** change many points on one data source in a single request. * **Mass write** discovers point groups across buildings, validates a plan, then runs and tracks the operation to completion. * **Templating** maps groups of points to ontology fields, then tracks the apply or clear operation. * **Actions** list and invoke data source commands, such as discovery, with the fields each action requires. * **Batch device updates** create, update, or delete many devices in one call. Start with [What is the KODE API?](/products/kode-api), then follow [Write to points](/products/kode-api/guides/write-to-points) for batch and mass writes, or [Apply templates to points](/products/kode-api/guides/apply-templates-to-points) for ontology templating. The API reference lists every endpoint with try-it samples in cURL, JavaScript, Python, and PowerShell. [Learn more about the KODE API](/products/kode-api) ## Weather device in KODE OS Buildings with Cloud BMS enabled receive a KODE-managed **Weather** device. Outdoor conditions appear as standard points next to equipment data. You do not connect a weather API key or install weather hardware for this feed. Open `Devices`, search for `Weather`, and use the Trends tab like any other device. Plot Outside Air Temp, humidity, pressure, wind, precipitation, weather code, and enthalpy alongside equipment readings. KODE protects the Weather datasource, device, and points so the feed stays intact. Recommended weather-aware FDD (Fault Detection and Diagnostics (FDD) finds building issues from broader analysis, not just simple instantaneous alarms.) rules are available in the KODE routine library. Enable the groups that match site equipment to validate outdoor sensors, watch economizers, and put heating and cooling in outdoor context. ![Weather device Trends with Outside Air Temp and Outside Air Pressure selected](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/whats-new/whats-new-v320-weather.png?fit=max\&auto=format\&n=Hw1Nqnl-vSrg3D4i\&q=85\&s=553263a8825b6c798e67ad2b7d8d727e) Open Weather on Devices and trend outdoor conditions next to equipment [Learn more about the Weather device](/products/kode-os/devices/weather) ## Check Usage and Replace Usage in Building BI Retiring a data source no longer means hunting through every dashboard by hand. From the data source row menu, choose `Check Usage` to see how many published and unpublished dashboards read from that source. Choose `Replace Usage` to map columns, metrics, calculated columns, URLs, actions, and parameters onto another data source in the same organization. `Auto Resolve` matches items with the same internal name and data type. Map the rest by hand, review unmapped items, then keep the original source or delete it after the move. Both sources lock while the job runs. Widgets that still point at a deleted source show a clear error instead of failing silently. Dashboard templates and Building Data Hub pipelines stay on the original source. Replace Usage moves dashboard and filter references only. ![Replace Usage workflow mapping fields between Building BI data sources](https://mintcdn.com/kodelabs/Hw1Nqnl-vSrg3D4i/images/whats-new/whats-new-v320-replace-usage.gif?s=79355c1b7b05fce907a3136efc2f965b) Check usage, map fields, and replace references in one guided flow [Learn more about replacing a data source](/products/building-bi/data-sources#replace-or-delete-a-data-source) ## Assisted meter mapping in EnerG The portfolio **Meters** page is one workspace for browsing meters, editing properties, and mapping meters to buildings and spaces. In **Map meters** mode, EnerG proposes buildings with a 0–100 match score, evidence reasons, and competing candidates. Approve one meter, a selection, or all eligible suggestions in the current filters. A high score alone does not commit a mapping. Batch updates change permitted fields across many meters and can be reversed. Excel download and upload support offline reference mapping with a preview of ready, blocked, unchanged, and skipped rows. [Learn more about assisted meter mapping](/products/energ/analytics/portfolio-meters#assisted-mapping) ## Full release notes User-facing product updates in 3.20. ### KODE API — Automations and building data * **Public KODE API** — Authenticate with a service account, then work with buildings, data sources, devices, points, timeseries, schedules, ontology, users, spaces, tenants, meters, actions, and AssetOps work orders. See [What is the KODE API?](/products/kode-api). * **Bulk writes and executions** — Batch point writes, mass write across buildings with validate-and-track operations, batch device create/update/delete, templating apply and clear, and data source action invoke. See [Write to points](/products/kode-api/guides/write-to-points) and [Apply templates to points](/products/kode-api/guides/apply-templates-to-points). * **Ingest and connectors** — Create devices and points on a KODE API data source, send current or historical values, and manage KODE API connectors. See [Ingest device data](/products/kode-api/guides/ingest-device-data) and [Connect your own devices](/products/kode-api/guides/connect-your-own-devices). ### KODE OS — Devices, graphics, and Trends * **Weather device** — Cloud BMS buildings get a KODE-managed Weather device (`externalWeather`) with outdoor temperature, humidity, pressure, wind, precipitation, weather code, and enthalpy points. Recommended weather FDD rules are available in the KODE routine library. See [Weather device](/products/kode-os/devices/weather). * **Floor plan sections** — Draw nested sections on one floor graphic so detail appears only when viewers click or zoom in. Canvas images support up to 3840×2160. See [Floor plan sections](/products/kode-os/graphics/floor-plans#floor-plan-sections). * **Trends usability** — Points group by ontology under each device. Collapse devices, use Select all, and open a tabular raw data view for up to one week. See [Trends](/products/kode-os/trends). ### Building BI — Data sources * **Check Usage and Replace Usage** — From the data source row menu, review Published and Unpublished dashboard counts, map references to another source, or delete with a defined error state for dependent widgets and filters. Dashboard templates and Building Data Hub pipelines are not migrated. See [Replace or delete a data source](/products/building-bi/data-sources#replace-or-delete-a-data-source). * **Replace datasources permission** — Launchpad includes a `Replace datasources` write permission next to `Delete datasources`. See [Permissions reference](/products/launchpad/client-organizations/apps/permissions-reference). ### EnerG — Meters * **Meter management and assisted mapping** — Browse, Edit properties, and Map meters modes on portfolio Meters. Match scores, bulk approval, batch property updates, and Excel reference mapping. See [Portfolio meters](/products/energ/analytics/portfolio-meters).